Você está na página 1de 32

SMART COMFORT & EASY EFFICIENCY

HEATING CONTROLS

About Delta Dore

Since 1970, Delta Dore manufactures heating controls for both


water based heating and electric heating. Room thermostats,
programmable thermostats, controllers, energy-consumption
meters.a wide range of solutions to improve comfort at
home and make savings on the energy bill.
The company designs controls for traditional heating systems
like boilers, electric heaters as well as for modern renewable
energy based heating systems like heat pumps
Thanks to its expertise with hard-wired and wireless communications, Delta Dore provides the end users with adjustable
features like control, programming, measure, remote control as
well as scalable features in home automation applications for
lighting control, opening detection
The company has a manufacturing facility of 10 000 square metres in France and offices in Germany, Poland and Spain. Delta
Dore supplies plumbers merchants, electrical wholesalers and
cooperates with the main European HVAC manufacturers.

Solutions perfectly suited for boilers, heat pumps and much


more
With energy prices and domestic consumption ever on the rise,
Delta Dore has strengthened its expertise to offer the end user:
- Maximum comfort with a wide range of heating control
and programming products
- Solutions to reduce the energy usage and then to take part
to the CO2 emission reduction effort.

Whats different about DELTA DORE?


A historical business in manufacturing electronic devices for heating systems
An innovative design to offer products:
- easy to install and set
- easy to understand and use
Products that meet the requirements of new and existing
Energy savings in figures
dwellings thanks to hard-wired and wireless versions
A strong expertise in RF technology and a communication
One extra degree could increase the heating bill by 7%.
protocol X2D dedicated to home automation applications
The right programming solution could generate
to ensure:
significant savings on the energy bill:
- the reliability of wireless solutions
- up to 25% saving when used on boilers
- the interoperability of heating control solutions
- up to 7% saving when used on heat pumps.
with further home automation applications.

CONTENTS

MONEY SAVINGS

PRODUCTS FULLY UPGRADABLE

APPLICATIONS

for boilers
> Room thermostat

> Programmable thermostat

for boilers or heat pumps


> 2-zone outdoor temperature compensated controller

> Up to 6 zones controller for underfloor heating

for heat pumps as boiler back-up


> 2-zone outdoor temperature controller

10

> 2-zone controller

11

for heat pumps


> Programmable thermostat

12

for solar panels


> Solar panel heated-DHW control

13

ADD-ON SOLUTIONS

14

FEATURES

16

Money savings
Lexpertise thermique
au service de votre projet

Chrono-proportional (P.I.) control


BENEFIT: Increase the energy efficiency
of heating systems by up to 10%
Each and every Delta Dore thermostat
controls the heating according to the
chrono-proportional control method.
The chrono-proportional control regularly
calculates the duration of the ON and OFF
periods in proportion to the difference between
the measured and set-point temperatures.
This ensures that the required temperature
is reached quickly and accurately, without
any sudden variations.

Programming
BENEFIT: Increase the energy efficiency
of heating systems by up to 12%
Tailored to the lifestyle of the occupants, the
programming function automatically lowers the
set-point temperature of one or more zones in
the dwelling during sleep and away periods each
day of the week.
Combined with a control function, the
programming helps to reduce the total heating
consumption.

Our combined control and programming products deliver thermal comfort all year round. And because everything is
automated, you no longer have to worry about getting too hot or too cold.

Products fully upgradable

Delta Dore offers a whole range of complementary


solutions so that more savings can be made.

Consumption metering
BENEFIT: Understand energy consumption
to start saving
View detailed consumption data with
our consumption meters and get electricity
usage measurements broken down by type
(heating, etc.).

Wireless magnetic contact


combined with heating control
BENEFIT: Automatically switch the heating
off when the window is open
Combine a door/window magnetic contact with
a wireless heating control.
Heating switches automatically to frost
protection mode when the window is opened.
It turns back to comfort mode when the window
is closed.

Telephone remote control


BENEFIT: Manage your heat consumption any
time, anywhere
Use a telephone remote control to manage
heating applications.
The perfect solution for secondary homes.

La Boiler
gestion
application
dnergie pour pompe chaleur rversible
Solutions
Solution
> Programmation
> Room thermostat
et rgulation sur temprature intrieure

Operating principle
The thermostat controls the temperature of the home
according to the temperature of the room.
It can be connected to the oil/gas boiler thermostat
input to the circulator pump.

Benefits
7% energy saving on the heating bill when using a room
thermostat
Easy to use
High precision control as the temperature sensor can be
calibrated to user-specific requirements

The solution includes:


Hard-wired version - D10: one room unit
Wireless version - Radio D10: one room unit
and one wireless receiver

D10/Radio D10 functions


Chrono-proportional (PI) control
Indication of room temperature
3 adjustable temperature settings: Comfort Setback
Frost Protection
Shutdown position
Settings can be locked
The wireless version solution is perfect for existing installations
- Quick to install
. Blends in with the home interior
. No unsightly cables between the thermostat
and receiver (located near the boiler)
- Radio range of 100 to 300 metres / 109 yd to 128 yd

Room Thermostat D10

Boiler

Receiver

Boiler

Products

Reference no.

D10

6050486

RADIO D10

6050487

Add-on solutions

Radio MINI COX magnetic contact - ref. 6412254


Telephone remote control
TYPHONE 5 SV - ref. 6201048
For more information about add-on solutions, refer to p.14-15

Wireless room Thermostat


Radio D10

Boiler application
Solution > Programmable thermostat

Operating principle
The programmable thermostat controls the temperature
of the home according to the temperature of the room.
The programming function allows the temperature of the specific
zone to be reduced according to occupants requirements to deliver
maximum comfort and energy savings.
It can be connected to the oil/gas boiler thermostat input to
hot water circuit(s) circulator pump(s).
The solution includes:
Hard-wired version - TYBOX 710/711/713/714: one room unit
Wireless version - Radio TYBOX 810/811: one room unit
and one wireless receiver
Wireless version - Radio TYBOX 820/821: two room units
and one wireless receiver

Benefits
10-25% saving on the heating bill thanks to the association
of control and programming functions
Elegant design
Large easy-to-read screen
Easy to use: the knob provides quick access to all thermostat functions

Programmable thermostat
TYBOX 713

High precision control as the temperature sensor can be


calibrated to user-specific requirements

Boiler

TYBOX and Radio TYBOX functions


Daily or weekly programming by zone
Programming by step of quarter hour, half hour or hour
Chrono-proportional (PI) control
An absence of 1 to 365 days can be programmed
Programs and settings can be locked
The wireless version solution is perfect for existing installations
- Quick to install
. Blends in with the home interior
. No unsightly cables between the thermostat
and receiver (located near the boiler)
- Radio range of 100 to 300 metres / 109 yd to 128 yd

Boiler

Products

Reference no.

TYBOX 710 - Batteries operated - 1 zone

6050478

TYBOX 711- 230 V - 1 zone

6050479

TYBOX 713 - Backlit - Batteries operated - 1 zone

6050505

TYBOX 714 - Backlit - 230 V - 1 zone

6050501

Radio TYBOX 810 - 1 zone

6050480

Radio TYBOX 820 - 2 zones

6050481

Radio TYBOX 811 - Backlit - 1 zone

6050503

Radio TYBOX 821 - Backlit - 2 zones

6050505

Receiver
Radio TYBOX 821

Programmable
thermostat
Radio TYBOX 821

Zone 2

Programmable
thermostat
Radio TYBOX 821

Zone 1

Add-on solutions

Radio MINI COX magnetic contact - ref. 6412254


Telephone remote control
TYPHONE 5 SV - ref. 6201048
For more information about add-on solutions, refer to p.14-15

Boiler or heat pump application


Solution > 2-zone outdoor temperature compensated controller

Operating principle
The DELTA 200 controller manages the heating
in the home according to the outdoor temperature
and to the underfloor system feed temperature.
It controls the opening and closing of the underfloor
heating mixing valve and activates/deactivates
2 circulator pumps to control the temperature
of 2 heating zones in the home.
The controller optimises heating within these zones
based on the outdoor temperature measured by the
sensor. It calculates the exact time required to reach the
desired temperature by the scheduled time, regardless of
weather conditions outside.
The programming function allows the temperature of the
specified zones to be reduced according to occupants
requirements to deliver maximum comfort and energy
savings.

The DELTA 200 solution includes:


A flush-mounted room unit, a technical unit, an outdoor temperature sensor, an underfloor system feed temperature sensor
and a return temperature sensor for the 2nd zone.

Benefits
Optimises temperature rises according to the weather
conditions for a more energy efficient home
Savings on the heating bill thanks to the association of
control and programming functions:
- 10-25% saving when used on a boiler
- 7-10% saving when used on a heat pump

Possible application for one hot water radiant floor zone and
one radiator zone, or two radiator zones.

Easy to use

Delta 200

DELTA 200

DELTA 200 functions


Daily or weekly programming by zone
Programming by step of hour
An absence of 1 to 99 days can be programmed
Program settings can be locked
Adjustment of minimum and maximum water
temperatures on both networks
Temperature control based on the heating curve

Zone 2

Outdoor
temperature
sensor

Sensor
Sensor

Zone 1

Product
DELTA 200

Reference no.
6000022

Add-on solutions
Consumption meters
TYWATT 30 - ref. 6110021
TYWATT TRI - ref. 6110023
For more information about add-on solutions, refer to p.14-15

Boiler or heat pump application


Solution > Up to 6 zones controller for underfloor heating

Operating principle
The DELTA 600 controller manages heating room by room
according to the temperature of each room.
It controls the buildings hot water underfloor heating
via 6 thermal actuator controls. Each DELTA 600 TH
thermostat controls the thermal actuator for the floor
assigned to it.
DELTA 600 TH programmable room thermostats can be
used to change the set-point temperature of each of the
zones at any time.
Heating is controlled centrally via DELTA 600 COM,
allowing the user to switch all the zones to economy
mode, for example, from a single point before leaving the
house.

The DELTA 600 solution includes:


A DELTA 600 BT technical unit, a DELTA 600 TH programmable
room thermostat for each target zone, and a DELTA 600 COM for
a central control function.

Benefits
Separately controls the temperature of up to
6 underfloor heating zones
Savings on the heating bill thanks to the association
of control and programming functions:
- 10-25% saving when used on a boiler
- 7-10% saving when used on a heat pump
Easy to use

Technical unit
DELTA 600 BT

DELTA 600 functions


Separate weekly programming for each
of the rooms or zones
Programming by step of hour
General control function to centralise
all the zones
In-built safety function to provide circuit
overpressure protection

DELTA 600 TH

DELTA 600 com


Centralised
control

Zone 6

Zone 5

Zone 4
Boiler
Zone 3
Zone 2

Zone 1

Products

Reference no.

DELTA 600 BT

6000023

DELTA 600 TH

6000024

DELTA 600 COM

6000025

LaHeat
gestion
pump
dnergie
as boiler
pour
back-up
pompe
application
chaleur non rversible
Solutions
Solution> >Programmation
2-zone outdoorettemperature
rgulation sur
compensated
tempraturecontroller
intrieure

Operating principle
The T1C-2 DIGIT electronic modular thermostat automatically
selects the heat pump or the boiler as the energy source according to the outdoor temperature.
Heating in the home is regulated according to the outdoor
temperature and to the underfloor system feed temperature.
The DELTA 200 controls the opening and closing of the underfloor heating mixing valve and activates/deactivates 2 circulator pumps to control the temperature of 2 heating zones in the
home.

The solution includes:


One technical unit (T1C-2 DIGIT), a flush-mounted room unit,
a technical unit, an outdoor temperature sensor, an underfloor
system feed temperature sensor and a return temperature
sensor for the 2nd zone (DELTA 200).

Benefits
The selection of the energy source (heat pump or boiler) is
managed automatically according to the outdoor temperature
in order to optimise energy consumption
Optimises temperature rises according to the weather
conditions for a more energy efficient home
Energy savings on the heating bill thanks to the association of
control and programming functions:
- 10-25% saving for boiler operation
- 7-25% saving for heat pump operation
Easy to use

Possible application for one hot water radiant floor zone and
one radiator zone or two radiator zones.

Delta 200

Outdoor
temperature
sensor

Technical unit
DELTA 200

T1C-2 digit

Zone 2

Functions
T1C-2 DIGIT
Outdoor
temperature
sensor

Selects the energy source to be used


Sets the minimum set-point temperature
to ensure optimum heat pump operation

Sensor

Zone 1

DELTA 200

Boiler

Daily or weekly programming by zone


Programming by step of an hour
An absence of 1 to 99 days can be programmed
Program settings can be locked
Adjustment of minimum and maximum water
temperatures on both networks
Temperature control based on the heating curve

Heat pump

Products

Reference no.

T1C-2 DIGIT

6150031

Outdoor sensor - ref. 6300001

Add-on solutions

DELTA 200

6000022

Consumption meters
TYWATT 30 - ref. 6110021
TYWATT TRI - ref. 6110023
For more information about add-on solutions, refer to p.14-15

10

Sensor

Mixing tank

Heat pump as boiler back-up application


Solution > 2-zone controller

Operating principle
The T1C-2 DIGIT electronic modular thermostat
automatically selects the heat pump or the boiler as the
energy source according to the outdoor temperature.
Heating in the home is regulated according
to the temperature of the room.
The programmable thermostats Radio TYBOX control
2 heating zones according to the temperature of each zone
by activating/deactivating the circulator pumps.

The solution includes:


One technical unit (T1C-2 DIGIT), two wireless room units
and one 2-channel wireless receiver (Radio TYBOX 821).

Benefits
The selection of the energy source (heat pump or boiler) is
managed automatically according to the outdoor
temperature to optimise energy consumption
Energy savings on the heating bill thanks to the association
of control and programming functions:
- 10-25% saving for boiler operation
- 7-10% saving for heat pump operation
Easy to use: the programmable thermostat knob
provides quick access to all thermostat functions
High precision control as the indoor temperature
sensor can be calibrated to user-specific requirements

T1C-2 digit

Receiver
Radio TYBOX 821
Programmable
thermostat
Radio TYBOX 821

Functions
T1C-2 DIGIT

Zone 2

Outdoor
temperature
sensor

Selects the energy source to be used


Sets the minimum set-point temperature
to ensure optimum heat pump operation

Programmable
thermostat
Radio TYBOX 8 21
Zone 1

Radio TYBOX 820/821

Boiler

Weekly programming by zone


Chrono-proportional control
Programming by step of quarter hour, half hour or hour
An absence of 1 to 365 days can be programmed
No unsightly cables between the thermostat and
receiver (located near the boiler)
Radio range of 100 to 300 metres / 109 yd to 128 yd
Programs and settings can be locked
Products

Heat pump

Reference no.

Add-on solutions

T1C-2 DIGIT

6150031

Outdoor sensor - ref. 6300001


Consumption meters
TYWATT 30 - ref. 6110021
TYWATT TRI - ref. 6110023

Radio TYBOX 820

6050481

Radio TYBOX 821 - Backlit

6050505

Mixing tank

Radio MINI COX magnetic contact - ref. 6412254


Telephone remote control
TYPHONE 5 SV - ref. 6201048
For more information about add-on solutions, refer to p.14-15

11

Heat pump application


Solution > Programmable thermostat

Operating principle
The programmable thermostat controls the temperature
of the home in heating or cooling mode according to the
temperature of the room (underfloor heating/cooling).
The programming function allows the temperature of
the specified zone to be reduced according to occupants
requirements to deliver maximum comfort and energy savings.
The programmable thermostat can control a heat pump using
one of 2 types of connection:
- in summer/winter mode via the change-over function
and the heat pumps thermostat input
- via the 2 thermostat inputs (heat mode or cooling mode).

The solution includes:


Hard-wired version - TYBOX 712/715: one room unit
Wireless version - Radio TYBOX 812/813: one room unit
and one wireless receiver

Benefits
Elegant design
Control a heat pump using heating or cooling mode

TYBOX 715

Radio TYBOX 813

7-10% saving on the energy bill thanks to the association


of control and programming function
Easy to use: the knob provides quick access to all
thermostat functions

Receiver
Radio TYBOX 813

High precision control as the temperature sensor


can be calibrated to user-specific requirements
Heat pump

TYBOX 712 and Radio TYBOX 812 functions


Weekly programming by zone
Chrono-proportional (PI) control
Heat pump protection with time base that can be set from 30 to 60 minutes
Programming by step of quarter hour,half hour or hour
An absence of 1 to 365 days can be programmed
Programs and settings can be locked
The wireless version solution is perfect for existing installations
- Quick to install
. Blends in with the home interior
. No unsightly cables between the thermostat
and receiver (located near the boiler)
- Radio range of 100 to 300 metres / 109 yd to 128 yd
Products

Reference no.

TYBOX 712

6050484

TYBOX 715 - Backlit

6050502

Radio TYBOX 812

6050485

Radio TYBOX 813 - Backlit

6050504

Add-on solutions

Radio MINI COX magnetic contact - ref. 6412254


Telephone remote control
TYPHONE 5 SV - ref. 6201048
For more information about add-on solutions, refer to p.14-15

12

Heat pump

Solar panel application


Solution > Solar panel heated-DHW control

Operating principle
The electronic modular thermostat controls the water
temperature in the circuit.
It controls the circulation of the heat transfer fluid based on
the difference in temperature between the water heater and
the solar panel.
For example:
If the temperature of the solar panel goes 10C above that of the
water heater, the thermostat activates the circulator so that the
heat transfer fluid can warm up the water heater.
If the temperature of the solar panel goes down to 2C above
that of the solar water heater, the thermostat stops the
circulator.

The T1D DIGIT solution includes:


One technical unit

T1D DIGIT functions


Frost protection function ensures circulation
of heat transfer fluid when the outdoor temperature falls
below a set threshold
Setting of two difference thresholds (large and small
difference)
Safety temperature setting (0 to 150 C)
Display of the 3 measured temperatures
3 sensor inputs (solar panel, water heater
and outdoor temperature)

Temperature
sensor 1

The solar panel

T1D DIGIT
Storage tank

DHW
Sensor 2

Thermostatic
mixing valve

Electric resistance

Solar cylinder

Products

References no.

T1D DIGIT

6050032

Add-on solutions
Underfloor or piping sensor - ref. 6300002

For more information about add-on solutions, refer to p.14-15

13

ADD-ON SOLUTIONS
ACCESSOIRES

Electricity consumption meters


Consumption meters measure electricity consumption for heating, domestic hot water, etc. and display usage in kWh.
Benefit: By providing a detailed view of consumption habits, these metres make users more aware of how resources are
being used and how energy bills can be reduced.

TYWATT 30

Reference no. 6110021

Consumption meter for a single-phase installation


Allows users to measure the kWh consumption of all or part of the electrical system (heating,
domestic hot water, heat pump, etc.)
Compatible with an electronic meter or an electromechanical meter
Displays the total KWh consumption by rate period
Double meter (one continuous and one that can be initialized)
Displays the maximum average power reached

TYWATT TRI

Reference no. 6110023

Consumption meter for three-phase installations


Allows users to measure the kWh consumption of all or part of the electrical system (heating,
domestic hot water, heat pump, etc.)
Compatible with all types of electronic and electromechanical meters
Displays the total KWh consumption by rate period
Double meter (one continuous and one that can be initialized)
Displays the maximum average power reached

Wireless magnetic contact


Door/window magnetic contact combined with wireless heating control.
Benefit: Prevents heat loss to deliver more energy savings.

MINI COX
Installed on windows and doorways, this mini magnetic contact reduces energy
consumption by switching the heating zone to frost protection mode when a window
is opened. It turns back to the preset level when the window is closed.

Reference no. 6412254

14

Telephone remote controls


Using a telephone remote control, heating applications can be controlled and settings may be changed
even when away from home.
Benefit: Heat consumption can be managed any time, anywhere.

TYPHONE 2 SV

TYPHONE 2 SV / TYPHONE 3 SV
Reference no. 6201022

TYPHONE 3 SV

Voice synthesis PSTN telephone remote control for heating and DHW
Can be used with a telephone answering machine
Access code protection
On/off or timer control of 2 (2 SV) or 3 (3 SV) outputs for different applications
(heating, domestic hot water tank, lighting)

Reference no. 6201020

TYPHONE 5 SV GSM
GSM telephone remote control for heating & DHW
On/Off control for different applications (heating, domestic hot water tank, lighting)
Can be associated to a wireless heating control to allow the remote control of heating modes:
temperature settings can be changed (Comfort, Backset, Frost protection, Auto)

Reference no. 6201048

15

FEATURES
ACCESSOIRES

Digital room thermostats

D10

Power supply: 2 x 1.5V AAA batteries (supplied)


One 2 A/230 V change-over dry contact
Control range 5 to 30 C
Dimensions: H 80 x L 80 x D 23 mm

Radio D10

Transmitter power supply: 2 x 1.5V AAA batteries (supplied)


Receiver power supply: 230 V/50 Hz
One 5 A/230 V dry contact
Control range 5 to 30 C
Radio frequency 868 MHz
Transmitter dimensions: H 80 x L 80 x D 23 mm
Receiver dimensions: H170 x L 54 x D 25 mm

1-zone hard-wired programmable thermostats for boilers or electric heating

TYBOX 710/713

Power supply: 2 x 1.5V AAA batteries (supplied)


One 2 A dry contact
Control range 5 to 30 C
Dimensions: H 104 x L 80 x D 35 mm

TYBOX 711/714

Power supply: 230 V/50 Hz


One 2 A dry contact
Control range 5 to 30 C
Dimensions: H 104 x L 80 x D 35 mm

1- or 2-zone wireless programmable thermostats for boilers or electric heating

Radio TYBOX 810/811

Radio TYBOX 820/821

16

Transmitter power supply: 2 x 1.5V AAA batteries (supplied)


Receiver power supply: 230 V/50 Hz
One 5 A/230 V dry contact
Control range 5 to 30 C
Radio frequency 868 MHz
Transmitter dimensions: H 104 x L 80 x D 37 mm
Receiver dimensions: H 100 x L 54 x D 24 mm

Transmitter power supply: 2 x 1.5V AAA batteries (supplied)


Receiver power supply: 230 V/50 Hz
Two 5 A/230 V dry contacts
Control range 5 to 30 C
Radio frequency 868 MHz
Transmitter dimensions: H 104 x L 80 x D 37 mm
Receiver dimensions: H 100 x L 54 x D 24 mm

2-zone outdoor temperature compensated controller

Room unit

Power supply via bus link to technical unit


Control range 5 to 30 C
Dimensions: H 95 x L 85 x D 16 mm

Technical unit

DELTA 200

Power supply: 230 V/ 50 Hz


One 2 A contact boiler control output
One 3-way valve output
Two 2 A contact circulator outputs
Supplied with outdoor sensor, feed sensor and water return sensor
Dimensions: H 80 x L 230 x D 70 mm

Up to 6 underfloor heating zones controller

DELTA 600 HT
Thermostat

DELTA 600

Power supply: 2 x 1.5V AAA batteries (supplied with each product)


Control range 5 to 30 C
Dimensions: H 121 x L 94 x D 31 mm

DELTA 600 COM


Power supply: 2 x 1.5V AAA batteries (supplied with each product)
Programmable room
Dimensions: H 121 x L 94 x D 31 mm
thermostat

DELTA 600 BT
Technical unit

Power supply: 230 V/50 Hz


Six 5 A contact valve control outputs
One 1 A contact control output for burner or circulator
Dimensions: H 80 x L 230 x D 70 mm

17

FEATURES

Programmable thermostats for reversible and non-reversible heat pumps

TYBOX 712/715

Power supply: 2 x 1.5V AAA batteries (supplied)


One 2 A contact output
One 2 A change-over contact output
Control range 5 to 30 C
Control time base can be set at 30/45/60 minutes
Dimensions: H 104 x L 80 x D 35 mm

Radio TYBOX 812/813

Transmitter power supply: 2 x 1.5V AAA batteries (supplied)


Receiver power supply: 230 V/50 Hz
Two 3 A configurable dry contact outputs
Control range 5 to 30 C
Control time base can be set at 30/45/60 minutes
Radio frequency 868 MHz
Transmitter dimensions: H 104 x L 80 x D 37 mm
Receiver dimensions: H 120 x L 54 x D 25 mm

Modular thermostats
Multi-application: control of the temperature and monitoring

T1C-2 DIGIT

Power supply: 230 V/50 Hz


3 control range -10 to 90 C
Accuracy temperature 0,2 to 2C
One 5 A configurable dry contact output
Dimensions: H 84 x L 53 x D 59 mm

Power supply: 230 V/50 Hz


3 control range -10 to 90 C
One 5 A configurable dry contact output
Accuracy temperature 0,2 to 2 C
Dimensions: H 84 x L 53 x D 59 mm

Solar panel heated-DHW control

T1D DIGIT

18

Ducted air conditioning system


Solution > Up to 6 zones controller

Operating principle
The radio DELTA 630 solution controls and programs
the temperature of the home in heating or cooling mode
according to the temperature of the room
Each DELTA 630 TH room thermostat controls the
motorised register of the zone or room assigned to it. It
can be used to change the set-point temperature locally at
any time.
The DELTA 630 MASTER programmer manages the
programming of each of the zones based on 2
temperature settings (Comfort or Setback)

Benefits
10-25% saving on the heating bill thanks to the
association of control and programming functions
Elegant design
Large Easy-to-read screen
Easy to use : the knob provides quick access to all
thermostat functions

Functions
Controls up to 6 register-equipped zones by time and
temperature
Daily or weekly centralised programming by zone
The wireless version solution is perfect for existing
installations :
- Quick to install
. Blends in with the home interior
. No unsightly cables between the thermostat
and technical unit
- Radio range of 100 to 300 metres
109 yd to 328 yd

Products

Reference no.

Pack DELTA 630 - Backlit

6050512

DELTA 630 TH - Backlit


DELTA 630 MASTER - Backlit
DELTA 630 BT

6050513
6050514
6050515

The Radio Pack DELTA 630 solution includes :


One technical unit (DELTA 630 BT), 4 wireless room
thermostats to control the first 4 registers (DELTA 630 TH),
one wireless programmer (DELTA 630 Master) and one limit
sensor.

Features
DELTA 630 MASTER programmer
Transmitter power supply: 2 x 1.5V AAA batteries (supplied)
One Change-Over command
Radio frequency 868 MHz
Dimensions: H 104 x L 80 x D 35 mm
DELTA 630 TH room thermostat
Transmitter power supply: 2 x 1.5V AAA batteries (supplied)
Radio frequency 868 MHz
Dimensions: H 80 x L 80 x D 23 mm
DELTA 630 BT technical unit
Includes one change-over temperature sensor which checks
the AC systems output temperature to activate or deactivate the
fan whenever the mode changes (heating/cooling).
Power supply 230 V
Three (non-powered 5 A 230 V), NO contact outputs : changeover, interior unit
One register power supply input
Six 230V / 24 V DC / 12 V DC register contact outputs
Dimensions: H 130 x L 180 x D 60 mm

Reversible AC split system application


Solution > Interface for infrared control of reversible air conditioning systems

Operating principle
The Radio D30 is an infrared interface that controls
reversible mode air conditioning systems. It can record up
to 22 remote control screens for AC split systems.
It gives access to three modes: heating / cooling and
fan mode. And local overrides can be done: Comfort
heating, Setback heating, comfort heating, fan speed...

The solution includes : one room unit.

Benefits
The thermostat operates by copying the infrared
signals of the original Ac split system remote controls and
can then manage a maximum number of existing and
further split AC systems without updating the product.
Several Radio D30 may be associated to a wireless
programmer to provide a programming function.

Radio D30

Features

Power supply: 230V / 50Hz


Radio frequency 868 MHz
Wireless range 150 to 200 metres / 164 yd to 218 yd
Dimensions: H 80 x L 80 x D 23 mm

AC split system

Heat pump

Products

Reference no.

Radio D30

6203001

Electric heating application


Solution > Programmers for electric heating systems with pilot wire

Operating principle
The DRIVER programmer controls electric heaters based on 2 temperature settings (Comfort, Setback). The
Comfort temperature is set on the heater. The Setback temperature is 3.5 below the set Comfort temperature.
The program is customised according to the occupants lifestyle. During the night or when occupants are out, the
programmer will lower the heating in the house to reduce unnecessary energy consumption. Depending on the model, it
can manage the programming of up to 3 separate zones.

A choice of 3 technologies are available, depending on the installation:


- Wireless/Pilot Wire, perfectly suited for existing dwellings
- Powerline carrier/Pilot Wire, perfectly suited for existing dwellings
- Pilot Wire, ideal for new dwellings

Benefits

10-25% saving on the heating bill thanks to the programming function


Easy to use : the knob provides quick access to all thermostat functions

Functions

Daily or weekly programming by zone


Timer-controlled zone override function, from 15 min to 72 hours
Permanent override function using the knob
Absence of 1 to 365 days can be programmed

Wireless programmer: Radio DRIVER

Features
Radio Driver
Power supplied by 2 AAA batteries (supplied)
2-year battery life
Radio frequency 868 MHz
Wireless range 150 to 200 metres / 164 yd to 218 yd
Dimensions: H 104 x L 80 x D 35 mm
RF 660 FP wireless receiver
6-order pilot wire outputs
Set-point level display
Dimensions: H 102.5 x L 54 x D 19 mm (Antenna excl.)

PLC programmer : DRIVER CPL

Features
PLC DRIVER
230 V power supply
No filter at the head of the system
Dimensions: H 128 x L 85 x D 31 mm
TC 51089 receivers
6-order pilot wire outputs
Set-point level display
Dimensions: H 170 x L 50 x D 25 mm

Programmer : DRIVER

Features

230 V power supply


6-order pilot wire outputs
Dimensions: H 104 x L 80 x D 35 mm

Products

Reference no.

Radio DRIVER 610 - 1 zone


Radio DRIVER 620 - 2 zones
Radio DRIVER 630 3 zones
RF 660 FP receivers

6051137
6051138
6051139
6050508

PLC DRIVER 210 - 1 zone


PLC DRIVER 220 - 2 zones
PLC DRIVER 230 - 3 zones
TC 51089 receivers

6051135
6051136
6051134
6051140

DRIVER 610 - 1 zone


DRIVER 620 2 zones

6050506
6050507

Electric heating application


Solution > Zone control by time and temperature

Operating principle
The programmable thermostat controls the temperature
by controlling the electric heaters in one zone. It sends
commands to the receivers through RF technology.
The programming function allows to reduce the
temperature of the room according to occupants
requirements to deliver maximum comfort and energy
savings.

Benefits
10-25% saving on heating bill thanks to the association
of control and programming functions
Elegant design
Large Easy-to-read screen
Easy to use : the knob provides quick access to all
thermostat functions
High precision control as the temperature sensor can be
calibrated to user-specific requirements

Programmable thermostat
Radio TYBOX 801

Functions
Daily or weekly programming
Programming by step of quarter hour, half hour or hour
Chrono-proportional (PI) control
An absence of 1 to 365 days can be programmed
Programs and settings can be locked
The wireless version solution is perfect for existing
installations
- Quick to install
. Blends in with the home interior

. No unsightly cables between the thermostat


programmable and receiver
- Radio range of 100 to 300 metres
109 yd to 328 yd

Products

Reference no.

Radio TYBOX 800


Radio TYBOX 801 - Backlit
Receiver RF642

6050509
6050511
6351081

The solution includes:


One wireless room unit (Radio TYBOX) by
zone and one wireless receiver (RF 642) for
each electric heater.

Features
Room unit (transmitter only)
Radio frequency 868 MHz
Power supplied by 2 AAA batteries (supplied)
Dimensions: H 104 x L 80 x D 35 mm
RF 642 receivers: 16 A wireless receiver
Radio frequency 868 MHz
16 A resistive contact output
Dimensions: H 120 x L 54 x D 25

Electric heating application


Solution > Up to 3 zones centralised control by time and temperature

Operating principle
The Radio DRIVER wireless programmer centrally
programmes the electric heating by zone for up to 3
zones/rooms.
Each Radio D10 wireless room thermostat controls the
temperature of the corresponding room by sending information
to the receivers associated with the electric heaters within the
zone.

Benefits
10-25% saving on the heating bill thanks to the association
of control and programming functions
Elegant design
Large Easy-to-read screen
Easy to use : the knob provides quick access to all
thermostat functions
Centralised programming for up to 3 zones

Functions
Radio Driver
Daily or weekly programming by zone
Programming by step of quarter hour, half hour
or hour
Timer-controlled zone override function, from
15 min to 72 hours
Permanent override function using the knob
An absence of 1 to 365 days can be programmed
Radio range of 150 to 200 metres / 164 yd to 218 yd

2-zone programmer
Radio DRIVER 620

Radio D10
Chrono-proportional (PI) control
3 adjustable temperature settings: Comfort Setback - Frost Protection
Shutdown position
Settings can be locked
The wireless solution is perfect for existing installations
- Quick to install
- Blends in with the home interior
- No unsightly cables between the
programmable thermostat and receiver
- Radio range of 100 to 300 metres
109 yd to 328 yd

Products

Reference no.

Radio DRIVER 610 1 zones


Radio DRIVER 620 2 zones
Radio DRIVER 630 3 zones
Radio D10
Receiver RF642

6051137
6051138
6051139
6050487
6351081

The solution includes:


One wireless programmer room unit (Radio
DRIVER), one wireless receiver (RF 642)
for each electric heater, and one wireless
room thermostat (Radio D10) for each zone

Features
Radio Driver 630 / 620 / 610

Power supplied by 2 AAA batteries (supplied)


2-year battery life
Radio frequency 868 MHz
Dimensions: H 104 x L 80 x D 35 mm

Radio D10
Transmitter power supply : 2 x 1.5V AAA batteries
(supplied)
Receiver power supply: 230 V/50 Hz
One 5 A/230 V dry contact
Control range 5 to 30 C
Radio frequency 868 MHz
Transmitter dimensions: H 80 x L 80 x D 23 mm
RF 642 receivers : 16 A wireless receiver
Radio frequency 868 MHz
16 A resistive contact output
Dimensions: H 120 x L 54 x D 25

Solid fuel boiler application: wood, wood pellets, coal


Solution > Controller

Operating principle
The DELTA 40/42 RF controller controls the
temperature
of
the
heating
water
circuit.
It
activates/deactivates the circulator pump based on the
temperature measured at the boiler's water outlet

When associated with a room thermostat, it also


controls the heating based on the room temperature.
The solution includes :
DELTA 40: One controller
DELTA 42 RF: One controller and one
wireless room thermostat

Functions
Allows the control of the heating circulator pump
according to the temperature measured at the boiler water
outlet.
Controller shutdown and frost protection functions.
The room temperature can be adjusted via a room
thermostat placed in the room. It can be wired directly
to a DELTA 40 controller or connected wirelessly to a
DELTA 42 controller.

DELTA 42 RF controller + Wireless room


thermostat
Chrono-proportional (PI) control
3 adjustable temperature settings : Comfort Setback - Frost Protection
Shutdown position
Settings can be locked
The wireless version solution is perfect for existing
installations
- Quick to install
. Blends in with the home interior
. No unsightly cables between the thermostat
and the controller
- Radio range of 100 to 300 metres
109 yd to 328 yd

Products

Reference no.

Add-on solution

DELTA 40

6000026

Hard-wired room thermostat

DELTA 42 RF
With wireless room thermostat

6000028

(supplied)

Features
DELTA 40

230 V, 50 Hz power supply, pre-wired


One 5 A 230 V relay output (heating circulator pump)
One heating temperature sensor input (sensor supplied)
One hard-wired thermostat input (thermostat not supplied)
Dimensions : H 135 x L 143 x D 45 mm

DELTA 42
Wireless controller
230 V, 50 Hz power supply (pre-wired)
One 5 A 230 V relay output (heating circulator pump)
One heating sensor input (sensor supplied)
Dimensions : H 135 x L 143 x D 45 mm
Wireless room thermostat
Power supply: 2 x 1.5 V AAA alkaline batteries (supplied)
2-year battery life
Radio frequency 868 MHz

Solid fuel boiler with fan application: wood, wood pellets, coal
Solution > Controller

Operating principle
The DELTA 41/43 RF controller controls the temperature
of the heating water circuit and the domestic hot water. It
activates/deactivates the circulator pumps based on the
temperature measured at the boiler's water outlet
It increases/decreases the air supply to the boiler by
controlling the fan.
When associated with a programmable thermostat, it also
controls and programs the heating based on the room
temperature.

The solution includes:


DELTA 41: One controller
DELTA 43 RF: One controller and one
wireless programmable thermostat

Functions
The controller allows the control of the heating circulator
pump according to the temperature measured at the boiler
water outlet.
It controls the circulator pump of the DHW.
Controller shutdown and frost protection function.
When associated with a programmable thermostat placed
in the users chosen location, it adjusts and programs the room
temperature.

DELTA 43 RF controller + Wireless programmable


thermostat
Daily or weekly programming by zone
Programming by step of quarter hour, half hour or hour
Chrono-proportional (PI) control
Programs and settings can be locked
The wireless version solution is perfect for existing
installations :
- Quick to install
. Blends in with the home interior
. No unsightly cables between the programmable
thermostat and the controller
- Radio range of 100 to 300 metres
109 yd to 328 yd

Products

Reference no.

Add-on solution

DELTA 41

6000027

. Hard-wired room thermostat


. Hard-wired programmable thermostat

DELTA 43 RF

6000029

With wireless programmable


thermostat (supplied)

Features
DELTA 41
230 V, 50 Hz power supply, pre-wired
One 5 A 230 V relay outputs (heating circulator pump,
DHW circulator pump, fan)
Two sensor inputs: heating and DHW (heating sensor
supplied)
One hard-wired thermostat input (thermostat not supplied))
Dimensions : H 135 x L 143 x D 45 mm

DELTA 43
Wireless controller
230 V, 50 Hz power supply, pre-wired
Three 5 A 230 V relay outputs (heating circulator pump,
DHW circulator pump, fan)
Two sensor inputs: heating and DHW (heating sensor
supplied)
Dimensions : H 135 x L 143 x D 45 mm
Wireless programmable thermostat
Power supply: 2 x 1.5 V AAA batteries (supplied)
Battery life: 2 years
Radio frequency 868 MHz

DELTA DORE
Headquarter : Bonnemain - 35270 Combourg - France

COM3700367 - Alyza - Credits : Manuel Clauzier and MCP Promotion

mail
export@deltadore.com

Você também pode gostar