NDT INSPECTION
REPORT NUMBER 15-391R

QA Page

Pontoon Ballast Tank Drawings

)XHO7DQN$:DWHU%DOODVW3RUW

FWD

AFT

SIDE SHELL OUTBOARD

PLATE A

PLATE A

L-1

1
L-2

3
L-3

5
WELD

L-4
PLATE B

PLATE B

L-5

3
L-6

L-7

WELD
FR - 26

LONGITUDINAL
CENTER LINE BHD

FR - 27

REFERENCE READINGS PS-WT-7AP-001

PROJECT : ULTRASONIC THICKNESS GAUGING


INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

DESCRIPTION /
LOCATION

BOTTOM TANK PLATING - WATER BALLAST


TANK 7A ( PONTOON ) PORT

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT81

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

BOTTOM TANK PLATING - WATER BALLAST TANK 7A ( PONTOON )


PORT - PS-WT-7AP-001

AREA IDENTIFICATION
Point Number
Plate A
1
2
3
4
5
Plate B
1
2
3
4
5

Drawing Ref: OES-15-162-UT81

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

Tank Bottom Plating FR 26-27

14.00

14.50

-3.6

-0.50

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.20

-1.4

-0.20

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.50

-3.6

-0.50

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.50

-3.6

-0.50

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.10

-0.7

-0.10

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.20

-1.4

-0.20

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

Tank Bottom Plating FR 26-27

14.00

14.20

-1.4

-0.20

SATISFACTORY

15

Page 1 of 1

FWD

AFT

SIDE SHELL OUTBOARD

PLATE A

PLATE A

L-1

L-2

L-3
WELD

L-4
PLATE B

PLATE B

L-5

L-6

L-7

WELD
FR - 26

LONGITUDINAL
CENTER LINE BHD

FR - 27

REFERENCE READINGS PS-WT-7AP-002

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

BOTTOM TANK STIFFENERS - WATER


BALLAST TANK 7A ( PONTOON ) PORT

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT82

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

BOTTOM TANK STIFFENERS - WATER BALLAST TANK 7A (PONTOON )


PORT - PS-WT-7AP-002

AREA IDENTIFICATION
Point Number
Plate A
6W
6F
7W
7F
Plate B
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Tank Bottom Stiffeners FR 26-27

12.00

11.60

Tank Bottom Stiffeners FR 26-27

15.90

16.10

Tank Bottom Stiffeners FR 26-27

12.00

12.20

Tank Bottom Stiffeners FR 26-27

15.90

Tank Bottom Stiffeners FR 26-27


Tank Bottom Stiffeners FR 26-27

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

3.3

0.40

SATISFACTORY

25

-1.3

-0.20

SATISFACTORY

25

-1.7

-0.20

SATISFACTORY

25

15.60

1.9

0.30

SATISFACTORY

25

12.00

11.70

2.5

0.30

SATISFACTORY

25

15.90

15.90

0.0

0.00

SATISFACTORY

25

Tank Bottom Stiffeners FR 26-27

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

Tank Bottom Stiffeners FR 26-27

15.90

15.50

2.5

0.40

SATISFACTORY

25

Page 1 of 1

Gauged Diminution
(%)

Drawing Ref: OES-15-162-UT82

FWD

AFT

SIDE SHELL OUTBOARD

PLATE A

PLATE A

L-1

L-2

3
L-3

5
WELD

L-4
PLATE B

PLATE B

L-5

3
L-6

L-7

WELD
FR - 26

LONGITUDINAL
CENTER LINE BHD

FR - 27

REFERENCE READINGS PS-WT-7AP-004

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

TOP TANK PLATING - WATER BALLAST


TANK 7A ( PONTOON ) PORT

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT83

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

TOP TANK PLATING - WATER BALLAST TANK 7A ( PONTOON ) PORT

AREA IDENTIFICATION
Point Number
Plate A
1
2
3
4
5
Plate B
1
2
3
4
5

Drawing Ref: OES-15-162-UT83

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

Tank Top Plating FR 26-27

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.00

0.0

0.00

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.20

-1.7

-0.20

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.00

0.0

0.00

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.00

0.0

0.00

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.00

0.0

0.00

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

Tank Top Plating FR 26-27

12.00

12.20

-1.7

-0.20

SATISFACTORY

15

Page 1 of 1

FWD

AFT

SIDE SHELL OUTBOARD

L-1
PLATE A

PLATE A

L-2

L-3
WELD

L-4

L-5

PLATE B

PLATE B

L-6

L-7

WELD
FR - 26

LONGITUDINAL
CENTER LINE BHD

FR - 27

REFERENCE READINGS PS-WT-7AP-003

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

TOP TANK STIFFENERS - WATER BALLAST


TANK 7A ( PONTOON ) PORT

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT84

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

TOP TANK STEFFENERS - WATER BALLAST TANK 7A ( PONTOON )


PORT

AREA IDENTIFICATION
Point Number
Plate A
6W
6F
7W
7F
Plate B
6W
6F
7W
7F

Drawing Ref: OES-15-162-UT84

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

Tank Top Stiffeners FR 26 -27

10.00

10.20

-2.0

-0.20

SATISFACTORY

25

Tank Top Stiffeners FR 26 -27

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

Tank Top Stiffeners FR 26 -27

10.00

10.20

-2.0

-0.20

SATISFACTORY

25

Tank Top Stiffeners FR 26 -27

10.00

10.50

-5.0

-0.50

SATISFACTORY

25

Tank Top Stiffeners FR 26 -27

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

Tank Top Stiffeners FR 26 -27

10.00

10.20

-2.0

-0.20

SATISFACTORY

25

Tank Top Stiffeners FR 26 -27

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

Tank Top Stiffeners FR 26 -27

10.00

10.20

-2.0

-0.20

SATISFACTORY

25

Page 1 of 1

AFT

FWD

TANK TOP

L - 11

PLATE C
L - 10

PLATE C

L-9

L-8

5
L-7

L-6
PLATE B

PLATE B

L-5

L-4

L-3
PLATE A

PLATE A

L-2

L-1

TANK BOTTOM
FR - 27

FR - 26

REFERENCE READINGS PS-WT-7AP-005

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

SIDE SHELL OUTBOARD PLATING - WATER


BALLAST 7A ( PONTOON ) PORT

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT85

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

SIDE SHELL OUTBOARD PLATING - WATER BALLAST TANK 7A


(PONTOON) PORT - PS-WT-7AP-005

AREA IDENTIFICATION
Point Number
Plate A
1
2
3
4
5
Plate B
1
2
3
4
5
Plate C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Drawing Ref: OES-15-162-UT85

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

Outboard Side Shell Plating FR 26-27

12.70

13.10

-3.1

-0.40

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

13.00

-2.4

-0.30

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

13.00

-2.4

-0.30

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.90

-1.6

-0.20

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.70

0.0

0.00

SATISFACTORY

15

Outboard Side Shell Plating FR 26-27

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

Page 1 of 1

AFT

FWD

TANK TOP
PLATE C

PLATE C
L - 11

L - 10

L-9

L-8

L-7

L-6
PLATE B

PLATE B

L-5

L-4

L-3

L-2
PLATE A

PLATE A

L-1

TANK BOTTOM
FR - 27

FR - 26

REFERENCE READINGS PS-WT-7AP-006

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

SIDE SHELL OUTBOARD PLATING - WATER


BALLAST 7A ( PONTOON ) PORT

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT86

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

SIDE SHELL OUTBOARD STIFFENERS - WATER BALLAST TANK 7A


(PONTOON) PORT - PS-WT-7AP-006

AREA IDENTIFICATION
Point Number
Plate A
6W
6F
7W
7F
Plate B
6W
6F
7W
7F
Plate C
6W
6F
7W
7F

Drawing Ref: OES-15-162-UT86

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

Outboard Side Shell Stiffeners FR 26-27

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

11.70

2.5

0.30

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

11.60

3.3

0.40

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

12.00

0.0

0.00

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

12.00

0.0

0.00

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

11.70

2.5

0.30

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

11.60

3.3

0.40

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

12.00

0.0

0.00

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

12.30

-2.5

-0.30

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

11.70

2.5

0.30

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

11.80

1.7

0.20

SATISFACTORY

25

Outboard Side Shell Stiffeners FR 26-27

12.00

11.30

5.8

0.70

SATISFACTORY

25

Page 1 of 1

R/S

ABS Wastage
Allowance (%)

PORT

STBD

TANK TOP

BEAM C

B-2

6
WEB STIFFENER

BEAM B

2
WEB STIFFENER

BEAM A

OUTBOARD SIDE SHELL

B-1

CENTERLINE W/T BULKHEAD

TANK BOTTOM

REFERENCE READINGS PS-WT-7AP-007


DRAWING LOOKING AFT

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION / WEB FRAME 27 - WATER BALLAST TANK 7A


LOCATION
( PONTOON ) PORT

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT87

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

AREA IDENTIFICATION
Point Number
Web Framing A
1
2
3
4
5
6
7
8
Web Framing B
1
2
3
4
5
6
7
8
Web Framing C
1
2
3
4
5
6
7
8
Web Frame Brackets
1
2
Web Frame Stiffeners
1
2

Report Number: 2015-162R

WEB FRAME 27 - WATER BALLAST TANK 7A ( PONTOON ) PORT


- PS-WT-7AP-007

Drawing Ref: OES-15-162-UT87

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

Web Frame 27

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

Web Frame 27

15.90

16.30

-2.5

-0.40

SATISFACTORY

25

Web Frame 27

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

Web Frame 27

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

Web Frame 27

15.90

16.30

-2.5

-0.40

SATISFACTORY

25

Web Frame 27

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

Web Frame 27

15.90

16.10

-1.3

-0.20

SATISFACTORY

25

Web Frame 27

15.90

16.40

-3.1

-0.50

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

14.00

14.00

0.0

0.00

SATISFACTORY

25

Web Frame 27

12.70

12.60

0.8

0.10

SATISFACTORY

25

Web Frame 27

12.70

12.50

1.6

0.20

SATISFACTORY

25

Web Frame 27

15.90

16.10

-1.3

-0.20

SATISFACTORY

25

Web Frame 27

15.90

16.30

-2.5

-0.40

SATISFACTORY

25

Page 1 of 1

PORT

STBD

TANK TOP

PLATE D

PLATE C

PLATE B

PLATE A

TANK BOTTOM

REFERENCE READINGS PS-WT-7AP-008

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

TRANSVERSE FRAME 25 - WATER BALLAST


TANK 7A ( PONTOON ) PORT

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT88

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

TRANSVERSE FRAME 25 - WATER BALLAST TANK 7A ( PONTOON )


PORT - PS-WT-7AP-008

AREA IDENTIFICATION
Point Number
Plate A
1
2
3
4
5
Plate B
1
2
3
4
5
Plate C
1
2
3
4
5
Plate D
1
2
3

Drawing Ref: OES-15-162-UT88

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.70

2.5

0.30

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.40

5.0

0.60

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.80

1.7

0.20

SATISFACTORY

25

Transverse Frame 25

12.00

11.90

0.8

0.10

SATISFACTORY

25

Transverse Frame 25

12.70

12.70

0.0

0.00

SATISFACTORY

25

Transverse Frame 25

25.40

25.40

0.0

0.00

SATISFACTORY

25

Transverse Frame 25

25.40

25.40

0.0

0.00

SATISFACTORY

25

Page 1 of 1

Water Ballast Tank 3RUW

PORT
FWD
STBD

AFT

FUEL OIL DAY TANK


(DWG. NO. H607-01)

FUEL OIL SETTING TANK


(DWG. NO. H607-01)

CANT.

P30
P29
P28
P27
P26
P25
P24
P23
P22
P21
P20
P19
P18
P17
P16
P15
P14
P13
P12
P11
P10
P9
P8
P7
P6
P5
P4
P3
P2
P1

L 75x75x6
CANT.

L 75x75x6

GDR.

CANT.
DN

CANT.

~
CRANE
COLUMN

GDR.

02
CANT.

CANT.

CANT.

GDR.

CANT.

~ G1

G2

DN

07

11

HATCH OPN'G
10'-6"x7'-0"

CANT.

REF.# 6

B L CANT.

GDR.

GDR.

CANT.

CANT.

01

LUBE OIL TANK


(DWG. NO. H607-01)

STAIR ACCESS
OPEINING

CANT.

GDR.

CLEAR OPENING

CANT.

BHD

(REF.)

GDR.
(REF.)

GDR.

CANT.

CANT.

~3/4" THK (REF)


(EH36)

08

(REF.)

HATCH

CANT.

06

(TYP)

G1

CANT.

09

HATCH

CANT.

CANT.

REF.# 8

CANT.

S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
S25
S26
S27
S28
S29
S30

B B

CANT.

CANT.
(TYP)

CANT.

CANT.

05

GDR.

CANT.

GDR.

CANT.

GDR.

DN

CANT.

04

CANT.

GDR.

CANT.

CANT.

CANT.

~ G1

GDR.

REF.# 6
10'-6"x7'-0"
HATCH OPN'G

B B

CANT.

CANT.
BL
GDR.

HATCH

CANT.

10

G1

B B

CANT.

CANT.

B
B
B

03

STAIR ACCESS
OPENING

B
CANT.

CANT.

CANT.

CRANE
COLUMN

GDR.

CANT.

CANT.

FR.41

FR.40

FR.39

FR.38 FR.37

FR.36

FR.35

FR.34

FR.33 FR.32

FR.31

FR.30

FR.29

FR.28

FR.27

FR.26

FR.25

FR.24

FR.23 FR.22.45 FR.22

FR.21

FR.20

FR.19

FR.18

FR.17.57 FR.17

FR.16

FR.15

FR.14

FR.13

FR.12

FR.11

FR.10

FR.9

FR.8.43 FR.8

FR.7

FR.6

FR.5

FR.4

FR.3

FR.2

FR.1

FR.O

PLAN AT UPPER DECK


A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


01

REPORT PS-WT-001

04

REPORT PS-WT-005

07

REPORT PS-WT-009

10

REPORT PS-WT-014

02

REPORT PS-WT-002

05

REPORT PS-WT-007

08

REPORT PS-WT-011 & 026

11

REPORT PS-WT-023

03

REPORT PS-WT-003

06

REPORT PS-WT-008

09

REPORT PS-WT-013

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:

UPPER DECK KEY PLAN

JOB No.

DWG. No.

14-1473

OES-14-1473-UT01

SCALE:

N.T.S

REV.

548 549

550 551 552 553 554 555 556 557

538 539

540 541 542 543 544 545 546 547

S10
S11

522 525 528 531 534 537

S12
521 524 527 530 533 536

S13
520 523 526 529 532 535

S14
372 375 378 381 384 387 390 393 396 399 402 405 408 411 414 417 420 423 426 429 432 435 438 441 444 447 450 453 456

459 462 465 468 471 474 477

480 483 486 489 492 495 498

501 504 507 510 513 516 519

S15
S16
371 374 377 380 383 386 389 392 395 398 401 404 407 410 413 416 419 422 425 428 431 434 437 440 443 446 449 452 455

458 461 464 467 470 473 476

479 482 485 488 491 494 497

500 503 506 509 512 515 518

S17
370 373 376 379 382 385 388 391 394 397 400 403 406 409 412 415 418 421 424 427 430 433 436 439 442 445 448 451 454

457 460 463 466 469 472 475

478 481 484 487 490 493 496

499 502 505 508 511 514 517

S18
S19

FR.17.57

FR.17

FR.16

FR.15

FR.14

FR.13

FR.11

FR.12

AUTOCAD LOCATOR DRAWING KEY


SATISFACTORY
SUBSTANTIAL
RENEWAL/REPLACE
TEST POINTS INDICATING
STIFFENERS (WEB / FLANGE)

XX

WELD
A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:
JOB No.

UPPER DECK PLATE


PS-WT-005
DWG. No.

14-1473

OES-14-1473-UT01D

SCALE:

N.T.S

REV.

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-005


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

Point Number
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01D

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.20

10.00

10.23

10.00

10.32

-2.0
-2.3
-3.2
3.6
-1.1
-0.4
0.4
-3.8
-2.3
33.4
-1.1
-2.1
-0.5
-1.4
17.3
1.6
-1.3
-5.0
29.1
-4.1
-5.1
-1.1
8.2
-6.7
-11.2
-0.4
-3.5
-5.7
-1.3
-1.0
-7.2
-1.4
14.2
0.2
-1.4
-4.2
-2.3

-0.20
-0.23
-0.32
0.36
-0.11
-0.04
0.04
-0.38
-0.23
3.34
-0.11
-0.21
-0.05
-0.14
1.73
0.16
-0.13
-0.50
2.91
-0.41
-0.51
-0.11
0.82
-0.67
-1.12
-0.04
-0.35
-0.57
-0.13
-0.10
-0.72
-0.14
1.42
0.02
-0.14
-0.42
-0.23

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SUBSTANTIAL
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.64

10.00

10.11

10.00

10.04

10.00

9.96

10.00

10.38

10.00

10.23

10.00

6.66

10.00

10.11

10.00

10.21

10.00

10.05

10.00

10.14

10.00

8.27

10.00

9.84

10.00

10.13

10.00

10.50

10.00

7.09

10.00

10.41

10.00

10.51

10.00

10.11

10.00

9.18

10.00

10.67

10.00

11.12

10.00

10.04

10.00

10.35

10.00

10.57

10.00

10.13

10.00

10.10

10.00

10.72

10.00

10.14

10.00

8.58

10.00

9.98

10.00

10.14

10.00

10.42

10.00

10.23

Page 1 of 5

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-005


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01D

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.47

10.00

9.58

-4.7
4.2
0.4
-1.3
-4.1
0.2
-1.3
-3.5
0.5
-1.1
-1.1
-2.6
-2.3
-3.6
-1.6
-1.6
-2.0
-1.4
14.6
-3.8
-6.3
-3.0
-2.3
-4.5
-3.0
-3.8
-0.1
-3.2
-1.0
-3.2
33.4
-1.1
-0.8
19.5
-1.1
23.5
-1.3
-2.6

-0.47
0.42
0.04
-0.13
-0.41
0.02
-0.13
-0.35
0.05
-0.11
-0.11
-0.26
-0.23
-0.36
-0.16
-0.16
-0.20
-0.14
1.46
-0.38
-0.63
-0.30
-0.23
-0.45
-0.30
-0.38
-0.01
-0.32
-0.10
-0.32
3.34
-0.11
-0.08
1.95
-0.11
2.35
-0.13
-0.26

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SUBSTANTIAL
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.96

10.00

10.13

10.00

10.41

10.00

9.98

10.00

10.13

10.00

10.35

10.00

9.95

10.00

10.11

10.00

10.11

10.00

10.26

10.00

10.23

10.00

10.36

10.00

10.16

10.00

10.16

10.00

10.20

10.00

10.14

10.00

8.54

10.00

10.38

10.00

10.63

10.00

10.30

10.00

10.23

10.00

10.45

10.00

10.30

10.00

10.38

10.00

10.01

10.00

10.32

10.00

10.10

10.00

10.32

10.00

6.66

10.00

10.11

10.00

10.08

10.00

8.05

10.00

10.11

10.00

7.65

10.00

10.13

10.00

10.26

Page 2 of 5

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-005


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01D

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

9.87

10.00

8.44

10.00

10.20

1.3
15.6
-2.0
2.5
-1.7
-3.5
11.2
20.8
-1.1
5.6
20.5
-2.9
8.1
19.9
-3.5
11.8
16.1
27.7
16.8
16.1
36.1
2.7
11.6
20.5
6.6
17.0
35.1
6.3
-1.0
29.7
15.5
-1.1
0.4
0.7
26.9
-2.3
0.5
-2.9

0.13
1.56
-0.20
0.25
-0.17
-0.35
1.12
2.08
-0.11
0.56
2.05
-0.29
0.81
1.99
-0.35
1.18
1.61
2.77
1.68
1.61
3.61
0.27
1.16
2.05
0.66
1.70
3.51
0.63
-0.10
2.97
1.55
-0.11
0.04
0.07
2.69
-0.23
0.05
-0.29

SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SUBSTANTIAL
REPLACE
REPLACE
REPLACE
REPLACE
REPLACE
SATISFACTORY
SUBSTANTIAL
REPLACE
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.75

10.00

10.17

10.00

10.35

10.00

8.88

10.00

7.92

10.00

10.11

10.00

9.44

10.00

7.95

10.00

10.29

10.00

9.19

10.00

8.01

10.00

10.35

10.00

8.82

10.00

8.39

10.00

7.23

10.00

8.32

10.00

8.39

10.00

6.39

10.00

9.73

10.00

8.84

10.00

7.95

10.00

9.34

10.00

8.30

10.00

6.49

10.00

9.37

10.00

10.10

10.00

7.03

10.00

8.45

10.00

10.11

10.00

9.96

10.00

9.93

10.00

7.31

10.00

10.23

10.00

9.95

10.00

10.29

Page 3 of 5

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-005


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Original Thickness
(mm)

Drawing Ref: OES-14-1473-UT01D

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

9.96

10.00

10.02

0.4
-0.2
29.4
-3.8
-0.8
5.7
27.1
2.0
2.2
43.4
12.1
0.7
47.5
12.2
3.9
24.4
15.2
-1.7
-2.6
2.6
-1.4
-2.9
0.2
-2.0
-2.9
18.8
8.2
4.2
17.3
32.1
12.4
1.3
10.2
-1.4
10.2
4.5
-2.1
9.6

0.04
-0.02
2.94
-0.38
-0.08
0.57
2.71
0.20
0.22
4.34
1.21
0.07
4.75
1.22
0.39
2.44
1.52
-0.17
-0.26
0.26
-0.14
-0.29
0.02
-0.20
-0.29
1.88
0.82
0.42
1.73
3.21
1.24
0.13
1.02
-0.14
1.02
0.45
-0.21
0.96

SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SUBSTANTIAL
SATISFACTORY
REPLACE
SUBSTANTIAL
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
REPLACE
SUBSTANTIAL
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

7.06

10.00

10.38

10.00

10.08

10.00

9.43

10.00

7.29

10.00

9.80

10.00

9.78

10.00

5.66

10.00

8.79

10.00

9.93

10.00

5.25

10.00

8.78

10.00

9.61

10.00

7.56

10.00

8.48

10.00

10.17

10.00

10.26

10.00

9.74

10.00

10.14

10.00

10.29

10.00

9.98

10.00

10.20

10.00

10.29

10.00

8.12

10.00

9.18

10.00

9.58

10.00

8.27

10.00

6.79

10.00

8.76

10.00

9.87

10.00

8.98

10.00

10.14

10.00

8.98

10.00

9.55

10.00

10.21

10.00

9.04

Page 4 of 5

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-005


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01D

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.01

10.00

9.01

10.00

10.14

10.00

10.10

10.00

10.11

-0.1
9.9
-1.4
-1.0
-1.1
0.7
-2.9
-2.4
-4.4
-2.9
-2.6
-9.3
1.3
-6.0
-5.0
-8.7
-5.0
-3.0
-2.0
-4.0
-4.1
38.9
6.0
14.0
-3.2
-3.3
-5.0
-5.9
2.7
27.6
25.9
-0.7
-2.4
15.5
-2.0
-3.3
-7.6

-0.01
0.99
-0.14
-0.10
-0.11
0.07
-0.29
-0.24
-0.44
-0.29
-0.26
-0.93
0.13
-0.60
-0.50
-0.87
-0.50
-0.30
-0.20
-0.40
-0.41
3.89
0.60
1.40
-0.32
-0.33
-0.50
-0.59
0.27
2.76
2.59
-0.07
-0.24
1.55
-0.20
-0.33
-0.76

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SUBSTANTIAL
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.93

10.00

10.29

10.00

10.24

10.00

10.44

10.00

10.29

10.00

10.26

10.00

10.93

10.00

9.87

10.00

10.60

10.00

10.50

10.00

10.87

10.00

10.50

10.00

10.30

10.00

10.20

10.00

10.40

10.00

10.41

10.00

6.11

10.00

9.40

10.00

8.60

10.00

10.32

10.00

10.33

10.00

10.50

10.00

10.59

10.00

9.73

10.00

7.24

10.00

7.41

10.00

10.07

10.00

10.24

10.00

8.45

10.00

10.20

10.00

10.33

10.00

10.76

Page 5 of 5

PORT

674

680

685

679

684

690

689

695

694

700

699

705

704

710

709

712

FWD

AFT

714

P1

716

718

720

717

719

721

CENTER LINE

STBD

675

0
S1
S2

673

678

683

688

693

698

703

708

711

713

715

S3
672

677

682

687

692

697

702

707

723

725

727

671

676

681

686

691

696

701

706

722

724

726

S4
S5
S6

732

737

742

747

752

757

762

767

771

773

S7
731

736

741

746

751

756

761

730

735

740

745

750

755

760

765

729

734

739

744

749

754

759

764

766

770

S8

772

S9
S10
S11
728

733

738

743

748

753

758

763

769

S12

768

AUTOCAD LOCATOR DRAWING KEY


SATISFACTORY

FR.17

FR.16

FR.15

FR.14

FR.13

FR.12

FR.11

FR.10

SUBSTANTIAL

FR.9

RENEWAL/REPLACE
TEST POINTS INDICATING
STIFFENERS (WEB / FLANGE)

XX

WELD
A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:
JOB No.

UPPER DECK PLATE


PS-WT-007
DWG. No.

14-1473

OES-14-1473-UT01E

SCALE:

N.T.S

REV.

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-007


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

Point Number
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01E

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.50

10.00

10.70

10.00

10.23

10.00

11.31

10.00

10.50

10.00

10.07

10.00

10.16

10.00

10.17

10.00

10.32

10.00

10.36

10.00

10.41

10.00

10.48

10.00

10.17

10.00

10.44

10.00

10.02

10.00

10.17

10.00

10.35

10.00

10.99

10.00

10.61

10.00

10.23

10.00

10.26

10.00

10.16

10.00

10.17

10.00

10.57

10.00

10.38

10.00

10.32

-5.0
-7.0
-2.3
-13.1
-5.0
-0.7
-1.6
-1.7
-3.2
-3.6
-4.1
-4.8
-1.7
-4.4
-0.2
-1.7
-3.5
-9.9
-6.1
-2.3
-2.6
-1.6
-1.7
-5.7
-3.8
-3.2
0.5
-1.7
-3.9
5.9
-0.5
18.9
-2.3
-3.3
-0.5
14.6
14.0

-0.50
-0.70
-0.23
-1.31
-0.50
-0.07
-0.16
-0.17
-0.32
-0.36
-0.41
-0.48
-0.17
-0.44
-0.02
-0.17
-0.35
-0.99
-0.61
-0.23
-0.26
-0.16
-0.17
-0.57
-0.38
-0.32
0.05
-0.17
-0.39
0.59
-0.05
1.89
-0.23
-0.33
-0.05
1.46
1.40

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SUBSTANTIAL
SUBSTANTIAL

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.95

10.00

10.17

10.00

10.39

10.00

9.41

10.00

10.05

10.00

8.11

10.00

10.23

10.00

10.33

10.00

10.05

10.00

8.54

10.00

8.60

Page 1 of 3

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-007


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01E

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

9.25

10.00

8.82

10.00

9.81

10.00

9.90

7.5
11.8
1.9
1.0
0.1
-0.1
-1.1
5.3
-95.4
-92.9
-98.4
-92.6
-94.2
-88.4
-5.6
11.9
1.0
-4.4
10.5
4.2
27.1
15.2
-2.1
17.0
-4.0
-0.7
-1.8
-2.7
-3.6
-3.2
19.1
8.2
1.0
8.5
-0.5
13.4
-5.9
2.4

0.75
1.18
0.19
0.10
0.01
-0.01
-0.11
0.53
-9.54
-9.29
-9.84
-9.26
-9.42
-8.84
-0.56
1.19
0.10
-0.44
1.05
0.42
2.71
1.52
-0.21
1.70
-0.40
-0.07
-0.18
-0.27
-0.36
-0.32
1.91
0.82
0.10
0.85
-0.05
1.34
-0.59
0.24

SATISFACTORY
SUBSTANTIAL
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SUBSTANTIAL
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SUBSTANTIAL
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.99

10.00

10.01

10.00

10.11

10.00

9.47

10.00

19.54

10.00

19.29

10.00

19.84

10.00

19.26

10.00

19.42

10.00

18.84

10.00

10.56

10.00

8.81

10.00

9.90

10.00

10.44

10.00

8.95

10.00

9.58

10.00

7.29

10.00

8.48

10.00

10.21

10.00

8.30

10.00

10.40

10.00

10.07

10.00

10.18

10.00

10.27

10.00

10.36

10.00

10.32

10.00

8.09

10.00

9.18

10.00

9.90

10.00

9.15

10.00

10.05

10.00

8.66

10.00

10.59

10.00

9.76

Page 2 of 3

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-007


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01E

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.30

10.00

9.89

-3.0
1.1
24.4
-2.5
1.6
10.9
-1.1
-0.4
-4.2
1.3
37.1
9.1
31.2
26.2
15.6
2.5
3.1
-1.7
-5.9
-5.0
-7.0
-7.0
-0.8
-4.2
10.6
-7.4
-7.0
-1.4

-0.30
0.11
2.44
-0.25
0.16
1.09
-0.11
-0.04
-0.42
0.13
3.71
0.91
3.12
2.62
1.56
0.25
0.31
-0.17
-0.59
-0.50
-0.70
-0.70
-0.08
-0.42
1.06
-0.74
-0.70
-0.14

SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
REPLACE
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

7.56

10.00

10.25

10.00

9.84

10.00

8.91

10.00

10.11

10.00

10.04

10.00

10.42

10.00

9.87

10.00

6.29

10.00

9.09

10.00

6.88

10.00

7.38

10.00

8.44

10.00

9.75

10.00

9.69

10.00

10.17

10.00

10.59

10.00

10.50

10.00

10.70

10.00

10.70

10.00

10.08

10.00

10.42

10.00

8.94

10.00

10.74

10.00

10.70

10.00

10.14

Page 3 of 3

PORT
FWD

663
632

641

644

647

650

653

656

634

636

638

640

643

646

649

652

655

631

635

367

639

642

645

648

651

654

609

612

615

618

621

624

627

630

608

611

614

617

620

623

626

629

607

610

613

616

619

622

625

628

591

594

597

600

603

606

590

593

596

599

602

605

589

592

595

598

601

604

588

560

563

566

569

572

575

578

581

584

587

559

562

565

568

571

574

577

580

583

586

558

561

564

567

570

573

576

579

582

585

STBD

AFT
AFT

P17
P16
P15
P14
P13
P12
P11
P10
P9
P8
P7
P6
P5
P4
P3
P2
P1
0

CENTER LINE

S1
S2
AUTOCAD LOCATOR DRAWING KEY

FR.17.57

FR.17

FR.16

FR.15

FR.14

FR.13

FR.12

FR.11

FR.10

FR.9

SATISFACTORY

FR.8.43

SUBSTANTIAL
RENEWAL/REPLACE
TEST POINTS INDICATING
STIFFENERS (WEB / FLANGE)

XX

WELD
A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:
JOB No.

UPPER DECK PLATE


PS-WT-008
DWG. No.

14-1473

OES-14-1473-UT01F

SCALE:

N.T.S

REV.

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-008


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

Point Number
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01F

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

11.27

10.00

10.88

10.00

10.69

10.00

10.26

10.00

10.73

10.00

10.14

10.00

10.41

10.00

10.92

10.00

10.54

10.00

10.59

10.00

10.79

-12.7
-8.8
-6.9
-2.6
-7.3
-1.4
-4.1
-9.2
-5.4
-5.9
-7.9
4.2
-2.1
-6.3
-3.7
-1.1
-4.7
34.2
9.2
20.8
25.8
-1.7
-3.5
-3.5
-4.1
3.9
37.4
11.3
17.6
-3.5
18.5
24.7
-8.5
-0.7
1.0
-0.8
-15.3

-1.27
-0.88
-0.69
-0.26
-0.73
-0.14
-0.41
-0.92
-0.54
-0.59
-0.79
0.42
-0.21
-0.63
-0.37
-0.11
-0.47
3.42
0.92
2.08
2.58
-0.17
-0.35
-0.35
-0.41
0.39
3.74
1.13
1.76
-0.35
1.85
2.47
-0.85
-0.07
0.10
-0.08
-1.53

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SUBSTANTIAL
REPLACE
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.58

10.00

10.21

10.00

10.63

10.00

10.37

10.00

10.11

10.00

10.47

10.00

6.58

10.00

9.08

10.00

7.92

10.00

7.42

10.00

10.17

10.00

10.35

10.00

10.35

10.00

10.41

10.00

9.61

10.00

6.26

10.00

8.87

10.00

8.24

10.00

10.35

10.00

8.15

10.00

7.53

10.00

10.85

10.00

10.07

10.00

9.90

10.00

10.08

10.00

11.53

Page 1 of 3

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-008


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01F

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.42

10.00

10.96

10.00

10.56

10.00

8.40

-4.2
-9.6
-5.6
16.0
25.9
-6.1
-2.6
30.0
-9.1
16.5
22.6
15.9
-3.3
-6.4
-0.2
1.6
-11.9
-4.1
-7.3
16.0
-4.0
-2.0
-4.7
14.4
-3.2
-3.3
-4.8
22.6
-2.0
-0.5
0.4
-8.2
-2.3
22.1
28.0
-5.9
-2.0
-7.3

-0.42
-0.96
-0.56
1.60
2.59
-0.61
-0.26
3.00
-0.91
1.65
2.26
1.59
-0.33
-0.64
-0.02
0.16
-1.19
-0.41
-0.73
1.60
-0.40
-0.20
-0.47
1.44
-0.32
-0.33
-0.48
2.26
-0.20
-0.05
0.04
-0.82
-0.23
2.21
2.80
-0.59
-0.20
-0.73

SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
REPLACE
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SUBSTANTIAL
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

7.41

10.00

10.61

10.00

10.26

10.00

7.00

10.00

10.91

10.00

8.35

10.00

7.74

10.00

8.41

10.00

10.33

10.00

10.64

10.00

10.02

10.00

9.84

10.00

11.19

10.00

10.41

10.00

10.73

10.00

8.40

10.00

10.40

10.00

10.20

10.00

10.47

10.00

8.56

10.00

10.32

10.00

10.33

10.00

10.48

10.00

7.74

10.00

10.20

10.00

10.05

10.00

9.96

10.00

10.82

10.00

10.23

10.00

7.79

10.00

7.20

10.00

10.59

10.00

10.20

10.00

10.73

Page 2 of 3

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-008


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01F

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.48

10.00

10.15

10.00

10.30

10.00

10.67

-4.8
-1.5
-3.0
-6.7
4.1
-3.8
44.0
-5.4
-5.3
-0.1
-5.3
-4.5
0.5
-3.8
-1.4
-9.6
-5.3
-1.0
-2.4
-2.6
-0.7
0.8
-3.5
-0.8

-0.48
-0.15
-0.30
-0.67
0.41
-0.38
4.40
-0.54
-0.53
-0.01
-0.53
-0.45
0.05
-0.38
-0.14
-0.96
-0.53
-0.10
-0.24
-0.26
-0.07
0.08
-0.35
-0.08

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.59

10.00

10.38

10.00

5.60

10.00

10.54

10.00

10.53

10.00

10.01

10.00

10.53

10.00

10.45

10.00

9.95

10.00

10.38

10.00

10.14

10.00

10.96

10.00

10.53

10.00

10.10

10.00

10.24

10.00

10.26

10.00

10.07

10.00

9.92

10.00

10.35

10.00

10.08

Page 3 of 3

PORT
FWD
STBD

AFT
AFT

P18
P17
P16
P15
659

661

664

667

670

791

793

795

658

660

663

666

669

790

792

794

662

665

668

783

785

787

657
775

777

779

781

774

776

778

780

P14
P13
797

799

801

803

P12

DN

P11

789

P10
P9

782

784

786

788

796

798

800

P8

802

P7
P6
P5

REF.# 8

P4

HATCH

FR.10

FR.9

FR.8.43

FR.8

FR.7

FR.6

FR.5

FR.4

FR.3

P3

FR.2

FR.1

FR.O

AUTOCAD LOCATOR DRAWING KEY


SATISFACTORY
SUBSTANTIAL
RENEWAL/REPLACE
TEST POINTS INDICATING
STIFFENERS (WEB / FLANGE)

XX

WELD
A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:
JOB No.

UPPER DECK PLATE


PS-WT-009
DWG. No.

14-1473

OES-14-1473-UT01G

SCALE:

N.T.S

REV.

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-009


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

Point Number
657
658
659
660
661
662
663
664
665
666
667
668
669
670
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01G

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.18

10.00

10.50

10.00

10.13

10.00

10.08

10.00

10.36

10.00

10.08

-1.8
-5.0
-1.3
-0.8
-3.6
-0.8
4.5
-0.5
-2.1
-2.3
0.2
-0.5
-1.1
-1.4
0.5
1.0
0.4
-1.7
0.1
-2.3
-4.2
0.7
-2.9
-27.9
-4.1
-28.1
-3.0
-25.4
-4.4
-27.5
-31.6
-31.1
-23.0
-31.3
-30.5
-29.3
-3.8

-0.18
-0.50
-0.13
-0.08
-0.36
-0.08
0.45
-0.05
-0.21
-0.23
0.02
-0.05
-0.11
-0.14
0.05
0.10
0.04
-0.17
0.01
-0.23
-0.42
0.07
-0.29
-2.79
-0.41
-2.81
-0.30
-2.54
-0.44
-2.75
-3.16
-3.11
-2.30
-3.13
-3.05
-2.93
-0.38

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.55

10.00

10.05

10.00

10.21

10.00

10.23

10.00

9.98

10.00

10.05

10.00

10.11

10.00

10.14

10.00

9.95

10.00

9.90

10.00

9.96

10.00

10.17

10.00

9.99

10.00

10.23

10.00

10.42

10.00

9.93

10.00

10.29

10.00

12.79

10.00

10.41

10.00

12.81

10.00

10.30

10.00

12.54

10.00

10.44

10.00

12.75

10.00

13.16

10.00

13.11

10.00

12.30

10.00

13.13

10.00

13.05

10.00

12.93

10.00

10.38

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-009


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

797
798
799
800
801
802
803

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01G

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

19.47

10.00

10.41

10.00

19.27

10.00

10.36

10.00

19.24

10.00

10.35

10.00

19.33

-94.7
-4.1
-92.7
-3.6
-92.4
-3.5
-93.3

-9.47
-0.41
-9.27
-0.36
-9.24
-0.35
-9.33

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15

Page 2 of 2

PORT
FWD

816

819

STBD

AFT

818

817

P30
P29

820

P28

823

P27

822
807

811

815

821

806

810

814

824

805

809

813

804

808

812

ENGINE
EXHAUST
828

P24
P23

826
830

832

833

835

836

838

839
845

P25

DAY TANKS

825

829

840

LUBE OIL TANK


(DWG. NO. H607-01)

827

P26

P22
P21

831

P20
P19
P18

837

BHD

P17
P16

841

842

P15

844

843

P14
P13

FR.21

FR.20

FR.19

FR.18

FR.17.57

FR.17

FR.16

FR.15

FR.14

FR.13

FR.12

AUTOCAD LOCATOR DRAWING KEY


SATISFACTORY
SUBSTANTIAL
RENEWAL/REPLACE
TEST POINTS INDICATING
STIFFENERS (WEB / FLANGE)

XX

WELD
A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:
JOB No.

UPPER DECK PLATE


PS-WT-011
DWG. No.

14-1473

OES-14-1473-UT01H

SCALE:

N.T.S

REV.

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-011


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

Point Number
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01H

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

6.27

10.00

6.80

10.00

6.79

37.3
32.0
32.1
5.9
-4.1
-7.8
22.5
-1.4
-7.0
-6.1
1.6
-1.4
17.9
8.1
0.1
-3.3
21.1
-4.2
-5.9
0.7
-7.6
23.2
16.7
4.2
2.6
-1.0
-7.5
24.4
-2.3
-1.7
0.7
0.4
1.1
0.4
1.6
-4.1
-1.4

3.73
3.20
3.21
0.59
-0.41
-0.78
2.25
-0.14
-0.70
-0.61
0.16
-0.14
1.79
0.81
0.01
-0.33
2.11
-0.42
-0.59
0.07
-0.76
2.32
1.67
0.42
0.26
-0.10
-0.75
2.44
-0.23
-0.17
0.07
0.04
0.11
0.04
0.16
-0.41
-0.14

REPLACE
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.41

10.00

10.41

10.00

10.78

10.00

7.75

10.00

10.14

10.00

10.70

10.00

10.61

10.00

9.84

10.00

10.14

10.00

8.21

10.00

9.19

10.00

9.99

10.00

10.33

10.00

7.89

10.00

10.42

10.00

10.59

10.00

9.93

10.00

10.76

10.00

7.68

10.00

8.33

10.00

9.58

10.00

9.74

10.00

10.10

10.00

10.75

10.00

7.56

10.00

10.23

10.00

10.17

10.00

9.93

10.00

9.96

10.00

9.89

10.00

9.96

10.00

9.84

10.00

10.41

10.00

10.14

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-011


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

841
842
843
844
845

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01H

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.39

10.00

9.37

10.00

9.81

10.00

9.93

10.00

9.60

-3.9
6.3
1.9
0.7
4.0

-0.39
0.63
0.19
0.07
0.40

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15

Page 2 of 2

PORT
STBD

CANT.

FWD

AFT

P16
P15
P14
P13
P12

DN
848

851

854

857

860

863

866

869

872

875

878

P11
P10

881

P9

CANT.
847

850

853

856

859

862

865

868

871

874

877

880

846

849

852

855

858

861

864

867

870

873

876

879

P8
P7
P6

CANT.
883

885

886

887

888

889

890

891

892
893

894

897

899

896

P5

REF.# 8
HATCH

898

P4

CANT.

P3

884

P2

882

895

CENTER LINE

P1

CANT.

0
S

S1

FR.11

FR.10

FR.9

FR.8.43

FR.8

FR.7

FR.6

FR.5

FR.4

FR.3

FR.2

FR.1

S2

FR.O

AUTOCAD LOCATOR DRAWING KEY


SATISFACTORY
SUBSTANTIAL
RENEWAL/REPLACE
TEST POINTS INDICATING
STIFFENERS (WEB / FLANGE)

XX

WELD
A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:
JOB No.

UPPER DECK PLATE


PS-WT-013
DWG. No.

14-1473

OES-14-1473-UT01I

SCALE:

N.T.S

REV.

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-013


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

Point Number
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01I

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

7.07

10.00

8.36

10.00

9.64

10.00

7.65

10.00

7.10

10.00

7.74

10.00

8.39

10.00

9.52

10.00

6.73

10.00

8.15

10.00

7.86

10.00

9.70

10.00

9.55

29.3
16.4
3.6
23.5
29.0
22.6
16.1
4.8
32.7
18.5
21.4
3.0
4.5
24.5
-2.0
-1.5
3.5
-3.3
-3.0
21.1
-3.3
-5.0
19.4
-3.2
8.0
22.8
-0.8
-4.5
22.5
-1.1
-2.3
-7.3
-4.3
-4.5
-7.3
-4.1
41.0

2.93
1.64
0.36
2.35
2.90
2.26
1.61
0.48
3.27
1.85
2.14
0.30
0.45
2.45
-0.20
-0.15
0.35
-0.33
-0.30
2.11
-0.33
-0.50
1.94
-0.32
0.80
2.28
-0.08
-0.45
2.25
-0.11
-0.23
-0.73
-0.43
-0.45
-0.73
-0.41
4.10

REPLACE
REPLACE
SATISFACTORY
REPLACE
REPLACE
REPLACE
REPLACE
SATISFACTORY
REPLACE
REPLACE
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

7.55

10.00

10.20

10.00

10.15

10.00

9.65

10.00

10.33

10.00

10.30

10.00

7.89

10.00

10.33

10.00

10.50

10.00

8.06

10.00

10.32

10.00

9.20

10.00

7.72

10.00

10.08

10.00

10.45

10.00

7.75

10.00

10.11

10.00

10.23

10.00

10.73

10.00

10.43

10.00

10.45

10.00

10.73

10.00

10.41

10.00

5.90

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-013


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01I

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

7.68

10.00

8.56

10.00

7.50

10.00

5.09

23.2
14.4
25.0
49.1
24.4
-1.4
34.5
-4.4
17.6
-6.1
-0.5
-6.3
2.0
0.1
-3.8
-3.8
-4.4

2.32
1.44
2.50
4.91
2.44
-0.14
3.45
-0.44
1.76
-0.61
-0.05
-0.63
0.20
0.01
-0.38
-0.38
-0.44

REPLACE
SUBSTANTIAL
REPLACE
REPLACE
REPLACE
SATISFACTORY
REPLACE
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

7.56

10.00

10.14

10.00

6.55

10.00

10.44

10.00

8.24

10.00

10.61

10.00

10.05

10.00

10.63

10.00

9.80

10.00

9.99

10.00

10.38

10.00

10.38

10.00

10.44

Page 2 of 2

PORT
FWD
STBD

AFT

CENTER LINE

901

902

904
906 908 910 912 914 916 918 920 922

900

903
905 907 909 911 913 915 917 919 921
949

927 929 931 933 935 936 937 938 939

923

924 925

926

928

930

932

934

940

941 942

943

944

945

946

947

DN

948

FR.7

FR.6

FR.5

FR.4

FR.3

FR.2

FR.1

P2
P1
0
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15

FR.O
AUTOCAD LOCATOR DRAWING KEY
SATISFACTORY
SUBSTANTIAL
RENEWAL/REPLACE
TEST POINTS INDICATING
STIFFENERS (WEB / FLANGE)

XX

WELD
A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:
JOB No.

UPPER DECK PLATE


PS-WT-014
DWG. No.

14-1473

OES-14-1473-UT01J

SCALE:

N.T.S

REV.

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-014


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

Point Number
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Original Thickness
(mm)

Drawing Ref: OES-14-1473-UT01J

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

9.84

10.00

11.27

1.6
-12.7
1.1
-0.7
6.9
-3.2
-3.8
-2.9
-3.2
-0.5
-3.8
-0.2
-1.1
-0.8
-2.0
-3.0
-1.1
3.6
-1.4
7.9
2.2
-1.7
-1.0
0.7
-0.8
0.1
-3.8
-5.9
-1.7
-3.1
-5.6
-6.7
-3.5
-5.9
-3.4
-2.1

0.16
-1.27
0.11
-0.07
0.69
-0.32
-0.38
-0.29
-0.32
-0.05
-0.38
-0.02
-0.11
-0.08
-0.20
-0.30
-0.11
0.36
-0.14
0.79
0.22
-0.17
-0.10
0.07
-0.08
0.01
-0.38
-0.59
-0.17
-0.31
-0.56
-0.67
-0.35
-0.59
-0.34
-0.21

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.89

10.00

10.07

10.00

9.31

10.00

10.32

10.00

10.38

10.00

10.29

10.00

10.32

10.00

10.05

10.00

10.38

10.00

10.02

10.00

10.11

10.00

10.08

10.00

10.20

10.00

10.30

10.00

10.11

10.00

9.64

10.00

10.14

10.00

9.21

10.00

9.78

10.00

10.17

10.00

10.10

10.00

9.93

10.00

10.08

10.00

9.99

10.00

10.38

10.00

10.59

10.00

10.17

10.00

10.31

10.00

10.56

10.00

10.67

10.00

10.35

10.00

10.59

10.00

10.34

10.00

10.21

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-014


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

936
937
938
939
940
941
942
943
944
945
946
947
948
949

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Drawing Ref: OES-14-1473-UT01J

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

10.41

10.00

9.96

-4.1
0.4
6.0
-5.9
1.0
-2.0
-1.5
1.0
6.0
6.3
4.5
3.8
-2.8
-0.8

-0.41
0.04
0.60
-0.59
0.10
-0.20
-0.15
0.10
0.60
0.63
0.45
0.38
-0.28
-0.08

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.40

10.00

10.59

10.00

9.90

10.00

10.20

10.00

10.15

10.00

9.90

10.00

9.40

10.00

9.37

10.00

9.55

10.00

9.62

10.00

10.28

10.00

10.08

Page 2 of 2

PORT
FWD
STBD

AFT

P30
963

962

961

960

959

958

957

956

955

954

953

952

951

P29

950

P28
P27
DN

P26
P25
P24
P23
P22
P21
P20
P19
P18

BHD

P17
P16

LUBE OIL TANK


(DWG. NO. H607-01)

P15
P14
P13

~ G1

P12

HATCH OPN'G
10'-6"x7'-0"

FR.21

FR.20

FR.19

FR.18

FR.17.57

FR.17

FR.16

FR.15

FR.14

FR.13

FR.12

FR.11

FR.10

FR.9
AUTOCAD LOCATOR DRAWING KEY
SATISFACTORY
SUBSTANTIAL
RENEWAL/REPLACE
TEST POINTS INDICATING
STIFFENERS (WEB / FLANGE)

XX

WELD
A

NOV 2014

R.S

T.M

J.K

REV.

DATE

BY

CHKD.

APPD.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

VESSEL:

SAFE CONCORDIA

PROJECT :

ULTRASONIC THICKNESS GAUGING

DESCRIPTION:
JOB No.

UPPER DECK PLATE


PS-WT-015
DWG. No.

14-1473

OES-14-1473-UT01K

SCALE:

N.T.S

REV.

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: November 2014

Report Number: 2014-1473R

UPPER DECK PS-WT-015


DECK PLATE

AREA IDENTIFICATION

DESCRIPTION

Point Number
950
951
952
953
954
955
956
957
958
959
960
961
962
963

DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE
DECK PLATE

Original Thickness
(mm)

Drawing Ref: OES-14-1473-UT01K

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

10.00

8.90

10.00

10.41

10.00

9.46

10.00

9.47

10.00

9.50

10.00

9.62

10.00

8.42

11.0
-4.1
5.4
5.3
5.0
3.8
15.8
1.0
-9.6
-4.7
-0.8
2.0
3.5
19.4

1.10
-0.41
0.54
0.53
0.50
0.38
1.58
0.10
-0.96
-0.47
-0.08
0.20
0.35
1.94

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
REPLACE

15
15
15
15
15
15
15
15
15
15
15
15
15
15

10.00

9.90

10.00

10.96

10.00

10.47

10.00

10.08

10.00

9.80

10.00

9.65

10.00

8.06

Page 1 of 1

FWD

AFT

TANK TOP

PLATE D

3
1

WELD
4
5
3

PLATE C

WELD

PLATE B
1

WELD

5
PLATE A

3
1

FR-1

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-2

TANK BOTTOM

LONGITUDINAL CENTERLINE WATERTIGHT


BHD PLATING-WATER BALLAST 1B
(PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT01

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

LONGITUDINAL CENTERLINE WATERTIGHT BHD PLATING-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT01

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5
PLATE D
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATE

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATE

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATE

12.00

21.00

-75.0

-9.00

SATISFACTORY

25

PLATE

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATE

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATE

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATE

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATE

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATE

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATE

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATE

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATE

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATE

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

PLATE

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

PLATE

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATE

12.00

18.90

-57.5

-6.90

SATISFACTORY

25

PLATE

12.00

18.90

-57.5

-6.90

SATISFACTORY

25

PLATE

12.00

18.90

-57.5

-6.90

SATISFACTORY

25

PLATE

12.00

18.90

-57.5

-6.90

SATISFACTORY

25

PLATE

12.00

18.90

-57.5

-6.90

SATISFACTORY

25

Page 1 of 1

FWD

AFT

TANK TOP

PLATE D

7
WELD

PLATE C
6

7
WELD

PLATE B

WELD

PLATE A
6

FR-1

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-2

TANK BOTTOM

LONGITUDINAL CENTERLINE WATERTIGHT


BHD STIFFENERS-WATER BALLAST 1B
(PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT02

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

LONGITUDINAL CENTERLINE WATERTIGHT BHD STIFFENERS-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT02

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F
PLATE D
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

Page 1 of 1

9RLG7DQN

%DVH/LQH:DOO9RLG7DQN3

FR - 23

AFT

FWD

L-19
L-20

TANK TOP

36

19

L-21

20

L-22
L-23

38

17

18

L-25
L-26
L-27

TANK TOP

L-28
L-29

40

15

33

16
42

13

34

14
NON WT CENTER BHD

11

12

OUTBOARD SHELL

10

L-29
L-28

TANK BOTTOM

L-25

21

22

23

24

41

L-27
L-26

FR - 22

39

NON WT-BHD

L-23

37

25

26

27

28

L-22

TANK BOTTOM

L-21
L-20

35

L-19

30

29

32

31

IN BOARD WT-BHD

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION / BASE LINE WALL - VOID TANK 10P FRAMES


LOCATION
23 & 22

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT01

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 23 & 22

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT01

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

12.70

13.02

-2.5

-0.32

SATISFACTORY

15

BASE LINE WALL

19.05

19.76

-3.7

-0.71

SATISFACTORY

15

BASE LINE WALL

7.93

7.74

2.4

0.19

SATISFACTORY

15

BASE LINE WALL

19.05

20.01

-5.0

-0.96

SATISFACTORY

15

BASE LINE WALL

7.93

7.96

-0.4

-0.03

SATISFACTORY

15

BASE LINE WALL

19.05

19.92

-4.6

-0.87

SATISFACTORY

15

BASE LINE WALL

7.93

7.95

-0.3

-0.02

SATISFACTORY

15

BASE LINE WALL

19.05

20.04

-5.2

-0.99

SATISFACTORY

15

BASE LINE WALL

12.70

10.85

14.6

1.85

SUBSTANTIAL

15

BASE LINE WALL

12.70

11.67

8.1

1.03

SATISFACTORY

15

BASE LINE WALL

12.70

10.66

16.1

2.04

REPLACE

15

BASE LINE WALL

12.70

11.63

8.4

1.07

SATISFACTORY

15

BASE LINE WALL

10.00

10.23

-2.3

-0.23

SATISFACTORY

20

BASE LINE WALL

10.00

10.36

-3.6

-0.36

SATISFACTORY

20

BASE LINE WALL

6.35

6.40

-0.8

-0.05

SATISFACTORY

20

BASE LINE WALL

6.35

6.36

-0.2

-0.01

SATISFACTORY

20

BASE LINE WALL

6.35

6.35

0.0

0.00

SATISFACTORY

20

BASE LINE WALL

6.35

6.30

0.8

0.05

SATISFACTORY

20

BASE LINE WALL

6.35

6.52

-2.7

-0.17

SATISFACTORY

20

BASE LINE WALL

6.35

6.35

0.0

0.00

SATISFACTORY

20

BASE LINE WALL

9.53

9.84

-3.3

-0.32

SATISFACTORY

20

BASE LINE WALL

9.53

9.81

-3.0

-0.29

SATISFACTORY

20

BASE LINE WALL

9.53

9.90

-3.9

-0.38

SATISFACTORY

20

BASE LINE WALL

9.53

10.10

-6.0

-0.57

SATISFACTORY

20

BASE LINE WALL

9.53

9.89

-3.8

-0.37

SATISFACTORY

20

BASE LINE WALL

9.53

9.59

-0.7

-0.06

SATISFACTORY

20

BASE LINE WALL

19.05

20.35

-6.8

-1.30

SATISFACTORY

20

BASE LINE WALL

19.05

19.21

-0.8

-0.16

SATISFACTORY

20

BASE LINE WALL

19.05

19.81

-4.0

-0.76

SATISFACTORY

20

BASE LINE WALL

19.05

19.91

-4.5

-0.86

SATISFACTORY

20

BASE LINE WALL

19.05

19.90

-4.5

-0.85

SATISFACTORY

20

BASE LINE WALL

19.05

19.78

-3.8

-0.73

SATISFACTORY

20

BASE LINE WALL

12.70

12.04

5.2

0.66

SATISFACTORY

20

BASE LINE WALL

12.70

11.96

5.8

0.74

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 23 & 22

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

7.00

6.23

BASE LINE WALL

7.00

5.87

BASE LINE WALL

7.00

6.72

BASE LINE WALL

7.00

6.78

BASE LINE WALL

7.00

BASE LINE WALL

7.00

Drawing Ref: OES-15-162-UT01

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

11.0

0.77

SATISFACTORY

20

16.1

1.13

SUBSTANTIAL

20

4.0

0.28

SATISFACTORY

20

3.1

0.22

SATISFACTORY

20

6.06

13.4

0.94

SATISFACTORY

20

5.95

15.0

1.05

SUBSTANTIAL

20

Longitudinal Stiffeners

BASE LINE WALL

7.00

7.35

-5.0

-0.35

SATISFACTORY

20

BASE LINE WALL

7.00

6.95

0.7

0.05

SATISFACTORY

20

BASE LINE WALL

12.70

12.80

-0.8

-0.10

SATISFACTORY

20

BASE LINE WALL

12.70

12.81

-0.9

-0.11

SATISFACTORY

20

BASE LINE WALL

7.00

7.06

-0.9

-0.06

SATISFACTORY

20

BASE LINE WALL

7.00

6.47

7.6

0.53

SATISFACTORY

20

BASE LINE WALL

12.70

12.73

-0.2

-0.03

SATISFACTORY

20

BASE LINE WALL

12.70

13.02

-2.5

-0.32

SATISFACTORY

20

BASE LINE WALL

7.00

6.88

1.7

0.12

SATISFACTORY

20

BASE LINE WALL

7.00

6.82

2.6

0.18

SATISFACTORY

20

Page 2 of 2

FR - 25

AFT

FWD

L-19
L-20

TANK TOP

36

19

L-21

20

L-22
L-23

38

17

18

L-25
L-26

TANK TOP

L-27
L-28
L-29

40

15

42

13

33

16

34

14
NON WT CENTER BHD

11

12

10

OUTBOARD SHELL

FR - 24
L-29
L-28

TANK BOTTOM

L-25

21

22

23

24

41

L-27
L-26

39

NON WT-BHD

L-23

37

25

26

27

28

L-22

TANK BOTTOM

L-21
L-20

35

L-19

30

29

32

31

IN BOARD WT-BHD

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

UT01 - BASE LINE WALL - VOID TANK 10P


FRAMES 25 & 24

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT02

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 25 & 24

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT02

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

7.94

7.98

-0.5

-0.04

SATISFACTORY

20

BASE LINE WALL

7.94

7.95

-0.1

-0.01

SATISFACTORY

20

BASE LINE WALL

7.94

7.92

0.3

0.02

SATISFACTORY

20

BASE LINE WALL

7.94

7.92

0.3

0.02

SATISFACTORY

20

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

BASE LINE WALL

7.94

8.11

-2.1

-0.17

SATISFACTORY

20

BASE LINE WALL

7.94

7.92

0.3

0.02

SATISFACTORY

20

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

BASE LINE WALL

10.00

10.26

-2.6

-0.26

SATISFACTORY

20

BASE LINE WALL

10.00

10.21

-2.1

-0.21

SATISFACTORY

20

BASE LINE WALL

10.00

10.23

-2.3

-0.23

SATISFACTORY

20

BASE LINE WALL

10.00

10.17

-1.7

-0.17

SATISFACTORY

20

BASE LINE WALL

6.35

6.51

-2.5

-0.16

SATISFACTORY

20

BASE LINE WALL

6.35

6.26

1.4

0.09

SATISFACTORY

20

BASE LINE WALL

6.35

5.66

10.9

0.69

SATISFACTORY

20

BASE LINE WALL

6.35

6.23

1.9

0.12

SATISFACTORY

20

BASE LINE WALL

6.35

6.33

0.3

0.02

SATISFACTORY

20

BASE LINE WALL

6.35

6.06

4.6

0.29

SATISFACTORY

20

BASE LINE WALL

6.35

6.24

1.7

0.11

SATISFACTORY

20

BASE LINE WALL

6.35

6.23

1.9

0.12

SATISFACTORY

20

BASE LINE WALL

6.35

6.11

3.8

0.24

SATISFACTORY

20

BASE LINE WALL

6.35

6.06

4.6

0.29

SATISFACTORY

20

BASE LINE WALL

6.35

6.20

2.4

0.15

SATISFACTORY

20

BASE LINE WALL

6.35

6.23

1.9

0.12

SATISFACTORY

20

BASE LINE WALL

6.35

6.55

-3.1

-0.20

SATISFACTORY

20

BASE LINE WALL

6.35

6.55

-3.1

-0.20

SATISFACTORY

20

BASE LINE WALL

6.35

6.32

0.5

0.03

SATISFACTORY

20

BASE LINE WALL

6.35

6.35

0.0

0.00

SATISFACTORY

20

BASE LINE WALL

10.00

10.20

-2.0

-0.20

SATISFACTORY

20

BASE LINE WALL

10.00

10.18

-1.8

-0.18

SATISFACTORY

20

BASE LINE WALL

10.00

10.14

-1.4

-0.14

SATISFACTORY

20

BASE LINE WALL

10.00

10.11

-1.1

-0.11

SATISFACTORY

20

BASE LINE WALL

7.94

8.09

-1.9

-0.15

SATISFACTORY

20

BASE LINE WALL

7.94

8.09

-1.9

-0.15

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 25 & 24

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

7.00

BASE LINE WALL

7.00

BASE LINE WALL

Gauged Thickness
(mm)

Drawing Ref: OES-15-162-UT02

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

6.47

7.6

0.53

SATISFACTORY

20

6.14

12.3

0.86

SATISFACTORY

20

7.00

7.01

-0.1

-0.01

SATISFACTORY

20

BASE LINE WALL

7.00

6.91

1.3

0.09

SATISFACTORY

20

BASE LINE WALL

7.00

6.17

11.9

0.83

SATISFACTORY

20

BASE LINE WALL

7.00

6.26

10.6

0.74

SATISFACTORY

20

BASE LINE WALL

7.00

6.09

13.0

0.91

SATISFACTORY

20

BASE LINE WALL

7.00

6.75

3.6

0.25

SATISFACTORY

20

BASE LINE WALL

12.70

12.84

-1.1

-0.14

SATISFACTORY

20

BASE LINE WALL

12.70

12.81

-0.9

-0.11

SATISFACTORY

20

BASE LINE WALL

7.00

7.35

-5.0

-0.35

SATISFACTORY

20

BASE LINE WALL

7.00

6.97

0.4

0.03

SATISFACTORY

20

BASE LINE WALL

12.70

13

-2.4

-0.30

SATISFACTORY

20

BASE LINE WALL

12.70

12.79

-0.7

-0.09

SATISFACTORY

20

BASE LINE WALL


BASE LINE WALL

7.00

6.66
6.24

4.9
10.9

0.34
0.76

SATISFACTORY
SATISFACTORY

20
20

Longitudinal Stiffeners

7.00

Page 2 of 2

FR - 27

AFT

FWD

L-19
L-20
L-21

TANK TOP

36

19

20

L-22
L-23

L-26
L-27

TANK TOP

38

17

L-28
L-29

18

40

15

33

16
42

13

34

14
NON WT CENTER BHD

11

12

10

21

22

23

24

OUTBOARD SHELL

L-29

41

L-28

TANK BOTTOM

L-27
L-26

FR - 26

39

NON WT-BHD

L-23

37

25

26

27

28

L-22

TANK BOTTOM

L-21
L-20

35

L-19

30

29

32

31

IN BOARD WT-BHD

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

UT01 - BASE LINE WALL - VOID TANK 10P


FRAMES 27 & 26

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT03

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 27 & 26

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT03

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

7.94

7.98

-0.5

-0.04

SATISFACTORY

15

BASE LINE WALL

7.94

8.02

-1.0

-0.08

SATISFACTORY

15

BASE LINE WALL

7.94

7.71

2.9

0.23

SATISFACTORY

15

BASE LINE WALL

7.94

7.86

1.0

0.08

SATISFACTORY

15

BASE LINE WALL

7.94

7.65

3.7

0.29

SATISFACTORY

15

BASE LINE WALL

7.94

7.98

-0.5

-0.04

SATISFACTORY

15

BASE LINE WALL

7.94

7.68

3.3

0.26

SATISFACTORY

15

BASE LINE WALL

7.94

6.55

17.5

1.39

REPLACE

15

BASE LINE WALL

10.00

10.05

-0.5

-0.05

SATISFACTORY

15

BASE LINE WALL

10.00

10.05

-0.5

-0.05

SATISFACTORY

15

BASE LINE WALL

10.00

10.29

-2.9

-0.29

SATISFACTORY

15

BASE LINE WALL

10.00

10.27

-2.7

-0.27

SATISFACTORY

15

BASE LINE WALL

6.35

6.40

-0.8

-0.05

SATISFACTORY

20

BASE LINE WALL

6.35

6.66

-4.9

-0.31

SATISFACTORY

20

BASE LINE WALL

6.35

6.33

0.3

0.02

SATISFACTORY

20

BASE LINE WALL

6.35

6.40

-0.8

-0.05

SATISFACTORY

20

BASE LINE WALL

6.35

6.05

4.7

0.30

SATISFACTORY

20

BASE LINE WALL

6.35

6.11

3.8

0.24

SATISFACTORY

20

BASE LINE WALL

6.35

6.26

1.4

0.09

SATISFACTORY

20

BASE LINE WALL

6.35

6.48

-2.0

-0.13

SATISFACTORY

20

BASE LINE WALL

6.35

6.17

2.8

0.18

SATISFACTORY

20

BASE LINE WALL

6.35

6.17

2.8

0.18

SATISFACTORY

20

BASE LINE WALL

6.35

6.15

3.1

0.20

SATISFACTORY

20

BASE LINE WALL

6.35

6.20

2.4

0.15

SATISFACTORY

20

BASE LINE WALL

6.35

6.46

-1.7

-0.11

SATISFACTORY

20

BASE LINE WALL

6.35

6.67

-5.0

-0.32

SATISFACTORY

20

BASE LINE WALL

6.35

6.37

-0.3

-0.02

SATISFACTORY

20

BASE LINE WALL

6.35

6.67

-5.0

-0.32

SATISFACTORY

20

BASE LINE WALL

7.94

8.04

-1.3

-0.10

SATISFACTORY

20

BASE LINE WALL

7.94

7.98

-0.5

-0.04

SATISFACTORY

20

BASE LINE WALL

7.94

7.99

-0.6

-0.05

SATISFACTORY

20

BASE LINE WALL

7.94

7.98

-0.5

-0.04

SATISFACTORY

20

BASE LINE WALL

7.94

8.06

-1.5

-0.12

SATISFACTORY

20

BASE LINE WALL

7.94

7.84

1.3

0.10

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 27 & 26

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

7.00

BASE LINE WALL

7.00

BASE LINE WALL

Gauged Thickness
(mm)

Drawing Ref: OES-15-162-UT03

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

6.91

1.3

0.09

SATISFACTORY

20

6.29

10.1

0.71

SATISFACTORY

20

7.00

7.07

-1.0

-0.07

SATISFACTORY

20

BASE LINE WALL

7.00

6.98

0.3

0.02

SATISFACTORY

20

BASE LINE WALL

7.00

6.29

10.1

0.71

SATISFACTORY

20

BASE LINE WALL

7.00

6.03

13.9

0.97

SATISFACTORY

20

BASE LINE WALL

7.00

7.00

0.0

0.00

SATISFACTORY

20

Longitudinal Stiffeners

BASE LINE WALL

7.00

6.76

3.4

0.24

SATISFACTORY

20

BASE LINE WALL

12.70

12.68

0.2

0.02

SATISFACTORY

20

BASE LINE WALL

12.70

12.79

-0.7

-0.09

SATISFACTORY

20

BASE LINE WALL

7.00

7.04

-0.6

-0.04

SATISFACTORY

20

BASE LINE WALL

7.00

6.64

5.1

0.36

SATISFACTORY

20

BASE LINE WALL

12.70

12.75

-0.4

-0.05

SATISFACTORY

20

BASE LINE WALL

12.70

12.75

-0.4

-0.05

SATISFACTORY

20

BASE LINE WALL

7.00

6.67

4.7

0.33

SATISFACTORY

20

BASE LINE WALL

7.00

6.49

7.3

0.51

SATISFACTORY

20

Page 2 of 2

FR - 29

AFT

FWD

L-19
L-20
L-21

TANK TOP

36

19

20

L-22
L-23
L-24

L-26
L-27

TANK TOP

L-28
L-29

17

38

40

15

42

13

18

33

16

34

14
NON WT CENTER BHD

11

12

10

21

22

23

24

OUTBOARD SHELL

L-29

41

L-28

TANK BOTTOM

L-27
L-26

FR - 28

39

NON WT-BHD
L-24
L-23

37

25

26

27

28

L-22

TANK BOTTOM

L-21
L-20

35

L-19

30

29

32

31

IN BOARD WT-BHD

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

UT01 - BASE LINE WALL - VOID TANK 10P


FRAMES 29 & 28

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT04

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 29 & 28

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT04

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

7.94

8.15

-2.6

-0.21

SATISFACTORY

15

BASE LINE WALL

7.94

8.39

-5.7

-0.45

SATISFACTORY

15

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

15

BASE LINE WALL

7.94

7.98

-0.5

-0.04

SATISFACTORY

15

BASE LINE WALL

7.94

8.06

-1.5

-0.12

SATISFACTORY

15

BASE LINE WALL

7.94

8.04

-1.3

-0.10

SATISFACTORY

15

BASE LINE WALL

7.94

8.14

-2.5

-0.20

SATISFACTORY

15

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

15

BASE LINE WALL

10.00

10.69

-6.9

-0.69

SATISFACTORY

15

BASE LINE WALL

10.00

10.69

-6.9

-0.69

SATISFACTORY

15

BASE LINE WALL

10.00

10.61

-6.1

-0.61

SATISFACTORY

15

BASE LINE WALL

10.00

10.61

-6.1

-0.61

SATISFACTORY

15

BASE LINE WALL

7.94

8.02

-1.0

-0.08

SATISFACTORY

20

BASE LINE WALL

7.94

7.75

2.4

0.19

SATISFACTORY

20

BASE LINE WALL

7.94

7.69

3.1

0.25

SATISFACTORY

20

BASE LINE WALL

7.94

7.86

1.0

0.08

SATISFACTORY

20

BASE LINE WALL

6.35

6.40

-0.8

-0.05

SATISFACTORY

20

BASE LINE WALL

6.35

6.40

-0.8

-0.05

SATISFACTORY

20

BASE LINE WALL

6.35

6.30

0.8

0.05

SATISFACTORY

20

BASE LINE WALL

6.35

6.90

-8.7

-0.55

SATISFACTORY

20

BASE LINE WALL

6.35

6.08

4.3

0.27

SATISFACTORY

20

BASE LINE WALL

6.35

6.08

4.3

0.27

SATISFACTORY

20

BASE LINE WALL

6.35

6.02

5.2

0.33

SATISFACTORY

20

BASE LINE WALL

6.35

6.02

5.2

0.33

SATISFACTORY

20

BASE LINE WALL

6.35

6.12

3.6

0.23

SATISFACTORY

20

BASE LINE WALL

6.35

6.18

2.7

0.17

SATISFACTORY

20

BASE LINE WALL

6.35

6.23

1.9

0.12

SATISFACTORY

20

BASE LINE WALL

6.35

6.32

0.5

0.03

SATISFACTORY

20

BASE LINE WALL

7.94

7.90

0.5

0.04

SATISFACTORY

20

BASE LINE WALL

7.94

7.89

0.6

0.05

SATISFACTORY

20

BASE LINE WALL

7.94

7.92

0.3

0.02

SATISFACTORY

20

BASE LINE WALL

7.94

7.89

0.6

0.05

SATISFACTORY

20

BASE LINE WALL

7.94

8.15

-2.6

-0.21

SATISFACTORY

20

BASE LINE WALL

7.94

8.32

-4.8

-0.38

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 29 & 28

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

7.00

BASE LINE WALL

7.00

BASE LINE WALL

Gauged Thickness
(mm)

Drawing Ref: OES-15-162-UT04

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

6.43

8.1

0.57

SATISFACTORY

20

6.05

13.6

0.95

SATISFACTORY

20

7.00

6.46

7.7

0.54

SATISFACTORY

20

BASE LINE WALL

7.00

6.35

9.3

0.65

SATISFACTORY

20

BASE LINE WALL

7.00

6.49

7.3

0.51

SATISFACTORY

20

BASE LINE WALL

7.00

6.21

11.3

0.79

SATISFACTORY

20

BASE LINE WALL

7.00

6.49

7.3

0.51

SATISFACTORY

20

Longitudinal Stiffeners

BASE LINE WALL

7.00

6.32

9.7

0.68

SATISFACTORY

20

BASE LINE WALL

12.70

12.97

-2.1

-0.27

SATISFACTORY

20

BASE LINE WALL

12.70

13.85

-9.1

-1.15

SATISFACTORY

20

BASE LINE WALL

12.70

13.24

-4.3

-0.54

SATISFACTORY

20

BASE LINE WALL

12.70

12.87

-1.3

-0.17

SATISFACTORY

20

BASE LINE WALL

12.70

13.02

-2.5

-0.32

SATISFACTORY

20

BASE LINE WALL

12.70

13.08

-3.0

-0.38

SATISFACTORY

20

BASE LINE WALL

12.70

12.93

-1.8

-0.23

SATISFACTORY

20

BASE LINE WALL

12.70

12.96

-2.0

-0.26

SATISFACTORY

20

Page 2 of 2

FR - 31

AFT

FWD

L-19
L-20
L-21

TANK TOP

36

19

20

L-22
L-23
L-24

L-26
L-27

TANK TOP

L-28
L-29

17

38

40

15

42

13

18

33

16

34

14
NON WT CENTER BHD

11

12

10

21

22

23

24

OUTBOARD SHELL

L-29

41

L-28

TANK BOTTOM

L-27
L-26

FR - 30

39

NON WT-BHD
L-24
L-23

37

25

26

27

28

L-22

TANK BOTTOM

L-21
L-20

35

L-19

30

29

32

31

IN BOARD WT-BHD

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

UT01 - BASE LINE WALL - VOID TANK 10P


FRAMES 31 & 30

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT05

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 31 & 30

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT05

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

7.94

8.06

-1.5

-0.12

SATISFACTORY

15

BASE LINE WALL

7.94

8.05

-1.4

-0.11

SATISFACTORY

15

BASE LINE WALL

7.94

7.81

1.6

0.13

SATISFACTORY

15

BASE LINE WALL

7.94

7.80

1.8

0.14

SATISFACTORY

15

BASE LINE WALL

7.94

7.69

3.1

0.25

SATISFACTORY

15

BASE LINE WALL

7.94

7.92

0.3

0.02

SATISFACTORY

15

BASE LINE WALL

7.94

7.87

0.9

0.07

SATISFACTORY

15

BASE LINE WALL

7.94

7.89

0.6

0.05

SATISFACTORY

15

BASE LINE WALL

10.00

10.85

-8.5

-0.85

SATISFACTORY

15

BASE LINE WALL

10.00

10.87

-8.7

-0.87

SATISFACTORY

15

BASE LINE WALL

10.00

10.82

-8.2

-0.82

SATISFACTORY

15

BASE LINE WALL

10.00

10.54

-5.4

-0.54

SATISFACTORY

15

BASE LINE WALL

6.35

6.11

3.8

0.24

SATISFACTORY

20

BASE LINE WALL

6.35

6.11

3.8

0.24

SATISFACTORY

20

BASE LINE WALL

6.35

6.12

3.6

0.23

SATISFACTORY

20

BASE LINE WALL

6.35

6.02

5.2

0.33

SATISFACTORY

20

BASE LINE WALL

6.35

6.09

4.1

0.26

SATISFACTORY

20

BASE LINE WALL

6.35

6.05

4.7

0.30

SATISFACTORY

20

BASE LINE WALL

6.35

6.11

3.8

0.24

SATISFACTORY

20

BASE LINE WALL

6.35

6.14

3.3

0.21

SATISFACTORY

20

BASE LINE WALL

7.94

7.80

1.8

0.14

SATISFACTORY

20

BASE LINE WALL

7.94

7.83

1.4

0.11

SATISFACTORY

20

BASE LINE WALL

7.94

7.86

1.0

0.08

SATISFACTORY

20

BASE LINE WALL

7.94

7.80

1.8

0.14

SATISFACTORY

20

BASE LINE WALL

7.94

7.93

0.1

0.01

SATISFACTORY

20

BASE LINE WALL

7.94

7.95

-0.1

-0.01

SATISFACTORY

20

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

BASE LINE WALL

7.94

7.83

1.4

0.11

SATISFACTORY

20

BASE LINE WALL

10.00

10.61

-6.1

-0.61

SATISFACTORY

20

BASE LINE WALL

10.00

10.61

-6.1

-0.61

SATISFACTORY

20

BASE LINE WALL

10.00

10.51

-5.1

-0.51

SATISFACTORY

20

BASE LINE WALL

10.00

10.29

-2.9

-0.29

SATISFACTORY

20

BASE LINE WALL

7.94

8.15

-2.6

-0.21

SATISFACTORY

20

BASE LINE WALL

7.94

8.21

-3.4

-0.27

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 31 & 30

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

9.00

BASE LINE WALL

9.00

Gauged Thickness
(mm)

Drawing Ref: OES-15-162-UT05

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

9.18

-2.0

-0.18

SATISFACTORY

20

8.09

10.1

0.91

SATISFACTORY

20

Longitudinal Stiffeners

BASE LINE WALL

7.00

5.59

20.1

1.41

REPLACE

20

BASE LINE WALL

7.00

5.90

15.7

1.10

SUBSTANTIAL

20

BASE LINE WALL

9.00

9.04

-0.4

-0.04

SATISFACTORY

20

BASE LINE WALL

9.00

8.04

10.7

0.96

SATISFACTORY

20

BASE LINE WALL

7.00

5.96

14.9

1.04

SATISFACTORY

20

BASE LINE WALL

7.00

5.84

16.6

1.16

SUBSTANTIAL

20

BASE LINE WALL

9.00

8.98

0.2

0.02

SATISFACTORY

20

BASE LINE WALL

9.00

8.48

5.8

0.52

SATISFACTORY

20

BASE LINE WALL

7.00

6.97

0.4

0.03

SATISFACTORY

20

BASE LINE WALL

7.00

5.93

15.3

1.07

SUBSTANTIAL

20

BASE LINE WALL

9.00

9.16

-1.8

-0.16

SATISFACTORY

20

BASE LINE WALL

9.00

8.24

8.4

0.76

SATISFACTORY

20

BASE LINE WALL

7.00

7.04

-0.6

-0.04

SATISFACTORY

20

BASE LINE WALL

7.00

6.79

3.0

0.21

SATISFACTORY

20

Page 2 of 2

FR - 34

AFT

FWD

L-19
L-20
L-21

TANK TOP

36

19

20

L-22
L-23
L-24

17

L-26

TANK TOP

40

15

L-27
L-28

33

16
42

13

L-29

18

38

34

14
NON WT CENTER BHD

11

12

10

21

22

23

24

OUTBOARD SHELL

L-29

41

L-28

TANK BOTTOM

L-27
L-26

FR - 33

39

NON WT-BHD
L-24
L-23

37

25

26

27

28

L-22

TANK BOTTOM

L-21
L-20

35

L-19

30

29

32

31

IN BOARD WT-BHD

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

UT01 - BASE LINE WALL - VOID TANK 10P


FRAMES 34 & 33

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT06

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 34 & 33

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT06

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

19.10

19.48

-2.0

-0.38

SATISFACTORY

15

BASE LINE WALL

19.10

19.45

-1.8

-0.35

SATISFACTORY

15

BASE LINE WALL

19.10

19.45

-1.8

-0.35

SATISFACTORY

15

BASE LINE WALL

19.10

19.45

-1.8

-0.35

SATISFACTORY

15

BASE LINE WALL

19.10

19.78

-3.6

-0.68

SATISFACTORY

15

BASE LINE WALL

19.10

19.51

-2.1

-0.41

SATISFACTORY

15

BASE LINE WALL

7.94

7.92

0.3

0.02

SATISFACTORY

15

BASE LINE WALL

19.10

19.58

-2.5

-0.48

SATISFACTORY

15

BASE LINE WALL

12.70

13.06

-2.8

-0.36

SATISFACTORY

15

BASE LINE WALL

12.70

12.78

-0.6

-0.08

SATISFACTORY

15

BASE LINE WALL

12.70

12.75

-0.4

-0.05

SATISFACTORY

15

BASE LINE WALL

12.70

12.76

-0.5

-0.06

SATISFACTORY

15

BASE LINE WALL

7.94

7.90

0.5

0.04

SATISFACTORY

20

BASE LINE WALL

7.94

7.95

-0.1

-0.01

SATISFACTORY

20

BASE LINE WALL

7.94

7.86

1.0

0.08

SATISFACTORY

20

BASE LINE WALL

7.94

7.93

0.1

0.01

SATISFACTORY

20

BASE LINE WALL

7.94

7.75

2.4

0.19

SATISFACTORY

20

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

BASE LINE WALL

7.94

7.75

2.4

0.19

SATISFACTORY

20

BASE LINE WALL

7.94

7.77

2.1

0.17

SATISFACTORY

20

BASE LINE WALL

12.70

12.48

1.7

0.22

SATISFACTORY

20

BASE LINE WALL

12.70

12.48

1.7

0.22

SATISFACTORY

20

BASE LINE WALL

12.70

12.76

-0.5

-0.06

SATISFACTORY

20

BASE LINE WALL

12.70

12.69

0.1

0.01

SATISFACTORY

20

BASE LINE WALL

12.70

12.65

0.4

0.05

SATISFACTORY

20

BASE LINE WALL

12.70

12.65

0.4

0.05

SATISFACTORY

20

BASE LINE WALL

12.70

12.66

0.3

0.04

SATISFACTORY

20

BASE LINE WALL

19.10

19.90

-4.2

-0.80

SATISFACTORY

20

BASE LINE WALL

19.10

19.81

-3.7

-0.71

SATISFACTORY

20

BASE LINE WALL

19.10

19.51

-2.1

-0.41

SATISFACTORY

20

BASE LINE WALL

19.10

19.48

-2.0

-0.38

SATISFACTORY

20

BASE LINE WALL

19.10

19.54

-2.3

-0.44

SATISFACTORY

20

BASE LINE WALL

12.70

13.11

-3.2

-0.41

SATISFACTORY

20

BASE LINE WALL

12.70

12.85

-1.2

-0.15

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 34 & 33

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

7.00

BASE LINE WALL

7.00

BASE LINE WALL

Gauged Thickness
(mm)

Drawing Ref: OES-15-162-UT06

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

6.67

4.7

0.33

SATISFACTORY

20

6.79

3.0

0.21

SATISFACTORY

20

7.00

6.48

7.4

0.52

SATISFACTORY

20

BASE LINE WALL

7.00

6.29

10.1

0.71

SATISFACTORY

20

BASE LINE WALL

7.00

6.89

1.6

0.11

SATISFACTORY

20

BASE LINE WALL

7.00

6.30

10.0

0.70

SATISFACTORY

20

BASE LINE WALL

7.00

6.49

7.3

0.51

SATISFACTORY

20

BASE LINE WALL

7.00

6.32

9.7

0.68

SATISFACTORY

20

BASE LINE WALL

7.00

6.23

11.0

0.77

SATISFACTORY

20

BASE LINE WALL

7.00

6.11

12.7

0.89

SATISFACTORY

20

BASE LINE WALL

7.00

6.67

4.7

0.33

SATISFACTORY

20

BASE LINE WALL

7.00

6.11

12.7

0.89

SATISFACTORY

20

BASE LINE WALL

7.00

6.00

14.3

1.00

SATISFACTORY

20

BASE LINE WALL

7.00

5.94

15.1

1.06

SUBSTANTIAL

20

Longitudinal Stiffeners

BASE LINE WALL

7.00

1.88

73.1

5.12

REPLACE

20

BASE LINE WALL

7.00

6.33

9.6

0.67

SATISFACTORY

20

Page 2 of 2

FR - 36

AFT

FWD

L-19
L-20
L-21

TANK TOP

36

19

20

L-22
L-23
L-24

17

L-26

TANK TOP

40

15

L-27
L-28

33

16
42

13

L-29

18

38

34

14
NON WT CENTER BHD

11

12

10

21

22

23

24

OUTBOARD SHELL

L-29

41

L-28

TANK BOTTOM

L-27
L-26

FR - 35

39

NON WT-BHD
L-24
L-23

37

25

26

27

28

L-22

TANK BOTTOM

L-21
L-20

35

L-19

30

29

32

31

IN BOARD WT-BHD

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

UT01 - BASE LINE WALL - VOID TANK 10P


FRAMES 36 & 35

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT07

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 36 & 35

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT07

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

19.10

19.72

-3.2

-0.62

SATISFACTORY

15

BASE LINE WALL

19.10

19.32

-1.2

-0.22

SATISFACTORY

15

BASE LINE WALL

19.10

19.54

-2.3

-0.44

SATISFACTORY

15

BASE LINE WALL

19.10

19.54

-2.3

-0.44

SATISFACTORY

15

BASE LINE WALL

19.10

19.52

-2.2

-0.42

SATISFACTORY

15

BASE LINE WALL

19.10

19.48

-2.0

-0.38

SATISFACTORY

15

BASE LINE WALL

7.94

6.68

15.9

1.26

REPLACE

15

BASE LINE WALL

7.94

7.77

2.1

0.17

SATISFACTORY

15

BASE LINE WALL

12.70

12.35

2.8

0.35

SATISFACTORY

15

BASE LINE WALL

12.70

12.79

-0.7

-0.09

SATISFACTORY

15

BASE LINE WALL

12.70

12.99

-2.3

-0.29

SATISFACTORY

15

BASE LINE WALL

12.70

12.93

-1.8

-0.23

SATISFACTORY

15

BASE LINE WALL

7.94

7.77

2.1

0.17

SATISFACTORY

20

BASE LINE WALL

7.94

8.15

-2.6

-0.21

SATISFACTORY

20

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

BASE LINE WALL

7.94

7.95

-0.1

-0.01

SATISFACTORY

20

BASE LINE WALL

7.94

7.96

-0.3

-0.02

SATISFACTORY

20

BASE LINE WALL

7.94

8.05

-1.4

-0.11

SATISFACTORY

20

BASE LINE WALL

7.94

7.95

-0.1

-0.01

SATISFACTORY

20

BASE LINE WALL

7.94

8.04

-1.3

-0.10

SATISFACTORY

20

BASE LINE WALL

6.35

6.17

2.8

0.18

SATISFACTORY

20

BASE LINE WALL

6.35

6.21

2.2

0.14

SATISFACTORY

20

BASE LINE WALL

6.35

6.40

-0.8

-0.05

SATISFACTORY

20

BASE LINE WALL

6.35

6.14

3.3

0.21

SATISFACTORY

20

BASE LINE WALL

6.35

5.83

8.2

0.52

SATISFACTORY

20

BASE LINE WALL

6.35

6.15

3.1

0.20

SATISFACTORY

20

BASE LINE WALL

6.35

6.09

4.1

0.26

SATISFACTORY

20

BASE LINE WALL

12.70

13.25

-4.3

-0.55

SATISFACTORY

20

BASE LINE WALL

15.88

16.37

-3.1

-0.49

SATISFACTORY

20

BASE LINE WALL

15.88

16.66

-4.9

-0.78

SATISFACTORY

20

BASE LINE WALL

15.88

16.40

-3.3

-0.52

SATISFACTORY

20

BASE LINE WALL

15.88

16.68

-5.0

-0.80

SATISFACTORY

20

BASE LINE WALL

12.70

13.11

-3.2

-0.41

SATISFACTORY

20

BASE LINE WALL

12.70

12.90

-1.6

-0.20

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 36 & 35

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

7.00

BASE LINE WALL

7.00

BASE LINE WALL

Gauged Thickness
(mm)

Drawing Ref: OES-15-162-UT07

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

6.88

1.7

0.12

SATISFACTORY

20

6.45

7.9

0.55

SATISFACTORY

20

7.00

6.55

6.4

0.45

SATISFACTORY

20

BASE LINE WALL

7.00

6.21

11.3

0.79

SATISFACTORY

20

BASE LINE WALL

7.00

6.26

10.6

0.74

SATISFACTORY

20

BASE LINE WALL

7.00

6.17

11.9

0.83

SATISFACTORY

20

BASE LINE WALL

7.00

6.64

5.1

0.36

SATISFACTORY

20

BASE LINE WALL

7.00

6.32

9.7

0.68

SATISFACTORY

20

BASE LINE WALL

7.00

6.92

1.1

0.08

SATISFACTORY

20

BASE LINE WALL

7.00

7.38

-5.4

-0.38

SATISFACTORY

20

BASE LINE WALL

7.00

6.58

6.0

0.42

SATISFACTORY

20

BASE LINE WALL

7.00

6.14

12.3

0.86

SATISFACTORY

20

BASE LINE WALL

7.00

6.15

12.1

0.85

SATISFACTORY

20

BASE LINE WALL

7.00

5.86

16.3

1.14

SUBSTANTIAL

20

BASE LINE WALL

7.00

6.70

4.3

0.30

SATISFACTORY

20

BASE LINE WALL

7.00

6.15

12.1

0.85

SATISFACTORY

20

Longitudinal Stiffeners

Page 2 of 2

FR - 38

AFT

FWD

L-19

19

36

20

TANK TOP

L-20
L-21
L-22

17

38

40

15

18

16

TANK TOP

42

13

14

L-23
L-24

L-26

33

34

L-27
L-28
L-29

NON WT CENTER BHD

11

12

10

OUTBOARD SHELL

FR - 37

21
7

41

TANK BOTTOM

39

22

L-29

L-28

23

L-27

24

L-26

CENTER NON WT-BHD

37

25

L-24

26

L-23
L-22

TANK BOTTOM

35

27

29

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

UT01 - BASE LINE WALL - VOID TANK 10P


FRAMES 38 & 37

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

L-21

28

30

31

L-20

32

L-19

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT08

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 38 & 37

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT08

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

19.10

19.51

-2.1

-0.41

SATISFACTORY

15

BASE LINE WALL

19.10

19.48

-2.0

-0.38

SATISFACTORY

15

BASE LINE WALL

19.10

19.54

-2.3

-0.44

SATISFACTORY

15

BASE LINE WALL

19.10

19.51

-2.1

-0.41

SATISFACTORY

15

BASE LINE WALL

19.10

19.49

-2.0

-0.39

SATISFACTORY

15

BASE LINE WALL

19.10

19.48

-2.0

-0.38

SATISFACTORY

15

BASE LINE WALL

19.10

19.55

-2.4

-0.45

SATISFACTORY

15

BASE LINE WALL

19.10

19.57

-2.5

-0.47

SATISFACTORY

15

BASE LINE WALL

19.10

19.76

-3.5

-0.66

SATISFACTORY

15

BASE LINE WALL

19.10

19.36

-1.4

-0.26

SATISFACTORY

15

BASE LINE WALL

19.10

19.60

-2.6

-0.50

SATISFACTORY

15

BASE LINE WALL

19.10

19.47

-1.9

-0.37

SATISFACTORY

15

BASE LINE WALL

10.00

10.11

-1.1

-0.11

SATISFACTORY

20

BASE LINE WALL

10.00

10.11

-1.1

-0.11

SATISFACTORY

20

BASE LINE WALL

7.94

7.75

2.4

0.19

SATISFACTORY

20

BASE LINE WALL

7.94

6.99

12.0

0.95

SATISFACTORY

20

BASE LINE WALL

7.94

7.89

0.6

0.05

SATISFACTORY

20

BASE LINE WALL

7.94

7.83

1.4

0.11

SATISFACTORY

20

BASE LINE WALL

7.94

7.92

0.3

0.02

SATISFACTORY

20

BASE LINE WALL

7.94

7.83

1.4

0.11

SATISFACTORY

20

BASE LINE WALL

12.70

12.60

0.8

0.10

SATISFACTORY

20

BASE LINE WALL

12.70

12.79

-0.7

-0.09

SATISFACTORY

20

BASE LINE WALL

12.70

12.60

0.8

0.10

SATISFACTORY

20

BASE LINE WALL

12.70

12.82

-0.9

-0.12

SATISFACTORY

20

BASE LINE WALL

12.70

12.82

-0.9

-0.12

SATISFACTORY

20

BASE LINE WALL

12.70

12.81

-0.9

-0.11

SATISFACTORY

20

BASE LINE WALL

12.70

12.60

0.8

0.10

SATISFACTORY

20

BASE LINE WALL

19.10

19.79

-3.6

-0.69

SATISFACTORY

20

BASE LINE WALL

19.10

19.75

-3.4

-0.65

SATISFACTORY

20

BASE LINE WALL

19.10

19.87

-4.0

-0.77

SATISFACTORY

20

BASE LINE WALL

19.10

19.72

-3.2

-0.62

SATISFACTORY

20

BASE LINE WALL

19.10

19.82

-3.8

-0.72

SATISFACTORY

20

BASE LINE WALL

19.10

19.63

-2.8

-0.53

SATISFACTORY

20

BASE LINE WALL

19.10

19.75

-3.4

-0.65

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 38 & 37

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

7.00

BASE LINE WALL

7.00

BASE LINE WALL

Gauged Thickness
(mm)

Drawing Ref: OES-15-162-UT08

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

6.88

1.7

0.12

SATISFACTORY

20

6.67

4.7

0.33

SATISFACTORY

20

7.00

6.67

4.7

0.33

SATISFACTORY

20

BASE LINE WALL

7.00

6.35

9.3

0.65

SATISFACTORY

20

BASE LINE WALL

7.00

6.14

12.3

0.86

SATISFACTORY

20

BASE LINE WALL

7.00

5.87

16.1

1.13

SUBSTANTIAL

20

BASE LINE WALL

7.00

6.64

5.1

0.36

SATISFACTORY

20

BASE LINE WALL

7.00

6.37

9.0

0.63

SATISFACTORY

20

BASE LINE WALL

7.00

7.15

-2.1

-0.15

SATISFACTORY

20

BASE LINE WALL

7.00

6.43

8.1

0.57

SATISFACTORY

20

BASE LINE WALL

7.00

6.51

7.0

0.49

SATISFACTORY

20

BASE LINE WALL

7.00

6.72

4.0

0.28

SATISFACTORY

20

BASE LINE WALL

7.00

6.46

7.7

0.54

SATISFACTORY

20

BASE LINE WALL

7.00

6.46

7.7

0.54

SATISFACTORY

20

BASE LINE WALL

7.00

6.79

3.0

0.21

SATISFACTORY

20

BASE LINE WALL

7.00

6.67

4.7

0.33

SATISFACTORY

20

Longitudinal Stiffeners

Page 2 of 2

FR - 40

AFT

FWD

L-19
L-20
L-21

TANK TOP

36

19

20

L-22
L-23
L-24

17

L-26

40

15

L-27

TANK TOP

38

L-28

42

13

L-29

18

33

16

34

14
NON WT CENTER BHD

11

12

OUTBOARD SHELL

L-29

L-27
L-26

21

22

23

24

41

L-28

TANK BOTTOM

FR - 39

10

39

NON WT-BHD
L-24
L-23

37

25

26

27

28

L-22

TANK BOTTOM

L-21
L-20

35

L-19

30

29

32

31

IN BOARD WT-BHD

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

UT01 - BASE LINE WALL - VOID TANK 10P


FRAMES 40 & 39

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT09

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 40 & 39

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Drawing Ref: OES-15-162-UT09

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

BASE LINE WALL

7.94

8.05

-1.4

-0.11

SATISFACTORY

15

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

15

BASE LINE WALL

7.94

7.84

1.3

0.10

SATISFACTORY

15

BASE LINE WALL

7.94

7.83

1.4

0.11

SATISFACTORY

15

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

15

BASE LINE WALL

7.94

7.98

-0.5

-0.04

SATISFACTORY

15

BASE LINE WALL

7.94

8.02

-1.0

-0.08

SATISFACTORY

15

BASE LINE WALL

7.94

8.04

-1.3

-0.10

SATISFACTORY

15

BASE LINE WALL

19.10

19.45

-1.8

-0.35

SATISFACTORY

15

BASE LINE WALL

19.10

19.84

-3.9

-0.74

SATISFACTORY

15

BASE LINE WALL

19.10

19.60

-2.6

-0.50

SATISFACTORY

15

BASE LINE WALL

19.10

19.61

-2.7

-0.51

SATISFACTORY

15

BASE LINE WALL

7.94

7.72

2.8

0.22

SATISFACTORY

20

BASE LINE WALL

7.94

8.04

-1.3

-0.10

SATISFACTORY

20

BASE LINE WALL

7.94

6.19

22.0

1.75

REPLACE

20

BASE LINE WALL

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

BASE LINE WALL

7.94

8.18

-3.0

-0.24

SATISFACTORY

20

BASE LINE WALL

7.94

8.09

-1.9

-0.15

SATISFACTORY

20

BASE LINE WALL

7.94

8.20

-3.3

-0.26

SATISFACTORY

20

BASE LINE WALL

7.94

8.14

-2.5

-0.20

SATISFACTORY

20

BASE LINE WALL

6.35

6.03

5.0

0.32

SATISFACTORY

20

BASE LINE WALL

6.35

6.14

3.3

0.21

SATISFACTORY

20

BASE LINE WALL

6.35

6.11

3.8

0.24

SATISFACTORY

20

BASE LINE WALL

6.35

6.11

3.8

0.24

SATISFACTORY

20

BASE LINE WALL

6.35

6.55

-3.1

-0.20

SATISFACTORY

20

BASE LINE WALL

6.35

6.64

-4.6

-0.29

SATISFACTORY

20

BASE LINE WALL

6.35

6.23

1.9

0.12

SATISFACTORY

20
20

BASE LINE WALL

6.35

6.26

1.4

0.09

SATISFACTORY

BASE LINE WALL

12.70

12.75

-0.4

-0.05

SATISFACTORY

20

BASE LINE WALL

12.70

12.51

1.5

0.19

SATISFACTORY

20

BASE LINE WALL

12.70

12.79

-0.7

-0.09

SATISFACTORY

20

BASE LINE WALL

12.70

12.51

1.5

0.19

SATISFACTORY

20

BASE LINE WALL

19.10

19.78

-3.6

-0.68

SATISFACTORY

20

BASE LINE WALL

19.10

19.78

-3.6

-0.68

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 10P FRAMES 40 & 39

Date: Jaunary 2015

Report Number: 2015-162R

BASE LINE WALL

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

35W
35F
36W
36F
37W
37F
38W
38F
39W
39F
40W
40F
41W
41F
42W
42F

BASE LINE WALL

7.00

6.17

BASE LINE WALL

7.00

5.90

BASE LINE WALL

7.00

6.61

BASE LINE WALL

7.00

6.23

BASE LINE WALL

7.00

7.19

BASE LINE WALL

7.00

6.46

BASE LINE WALL

7.00

BASE LINE WALL

7.00

BASE LINE WALL

Drawing Ref: OES-15-162-UT09

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

11.9

0.83

SATISFACTORY

20

15.7

1.10

SUBSTANTIAL

20

5.6

0.39

SATISFACTORY

20

11.0

0.77

SATISFACTORY

20

-2.7

-0.19

SATISFACTORY

20

7.7

0.54

SATISFACTORY

20

6.55

6.4

0.45

SATISFACTORY

20

6.12

12.6

0.88

SATISFACTORY

20

7.00

6.52

6.9

0.48

SATISFACTORY

20

BASE LINE WALL

7.00

6.37

9.0

0.63

SATISFACTORY

20

BASE LINE WALL

7.00

6.61

5.6

0.39

SATISFACTORY

20

BASE LINE WALL

7.00

7.25

-3.6

-0.25

SATISFACTORY

20

BASE LINE WALL

7.00

6.27

10.4

0.73

SATISFACTORY

20

BASE LINE WALL

7.00

6.26

10.6

0.74

SATISFACTORY

20

BASE LINE WALL

7.00

6.70

4.3

0.30

SATISFACTORY

20

BASE LINE WALL

7.00

6.14

12.3

0.86

SATISFACTORY

20

Longitudinal Stiffeners

Page 2 of 2

&HQWHU/LQH3RUW6LGH&0DLQ'HFN

PORT
17

FRAME 38

16

15

21

14

13

23

92

85

12

11

10

09

08

07

25

94

06

05

27

96

04

03

02

01

STBD

CL

29

98

100

22

24

26

28

30

41

43

45

47

49

TANK TOP

86
FRAME 37
LEVEL 67

CENTER LINE NON W/T BULKHEAD

INBOARD SHELL

42

44

46

48

50

LEVEL 62
FRAME 37

83

84

91

93

95

97

99

10

61

63

65

67

69

TANK BOTTOM

FRAME 38

81

82

LEVEL 62

FRAME 18 PORT SIDE

AFT SHELL

62

64

66

68

70

LEVEL 67

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

CENTER LINE TO PORT SIDE - VOID


TANK 13C MAIN DECK LEVEL 62 TO 67 FRAME 38 TO 37

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT12

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

CENTER LINE TO PORT & STARBOARD SIDE - VOID TANK 13C MAIN
DECK LEVEL 62 TO 67 - FRAME 38 TO 37

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
21
22
23
24
25
26
27
28
29
30
41
42
43
44
45
46
47
48
49
50
61
62
63
64
65
66

Drawing Ref: OES-15-162-UT13

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PORT SIDE

19.10

20.10

-5.2

-1.00

SATISFACTORY

15

PORT SIDE

19.10

20.10

-5.2

-1.00

SATISFACTORY

15

PORT SIDE

11.12

10.92

1.8

0.20

SATISFACTORY

15

PORT SIDE

11.12

10.72

3.6

0.40

SATISFACTORY

15

PORT SIDE

9.53

8.93

6.3

0.60

SATISFACTORY

15

PORT SIDE

9.53

8.54

10.4

0.99

SATISFACTORY

15

PORT SIDE

7.94

8.70

-9.6

-0.76

SATISFACTORY

15

PORT SIDE

7.94

8.58

-8.1

-0.64

SATISFACTORY

15

PORT SIDE

7.94

8.52

-7.3

-0.58

SATISFACTORY

15

PORT SIDE

7.94

8.53

-7.4

-0.59

SATISFACTORY

15

PORT SIDE

7.94

8.40

-5.8

-0.46

SATISFACTORY

20

PORT SIDE

7.94

8.25

-3.9

-0.31

SATISFACTORY

20

PORT SIDE

7.94

7.83

1.4

0.11

SATISFACTORY

20

PORT SIDE

7.94

7.71

2.9

0.23

SATISFACTORY

20

PORT SIDE

7.94

8.20

-3.3

-0.26

SATISFACTORY

20

PORT SIDE

7.94

8.26

-4.0

-0.32

SATISFACTORY

20

PORT SIDE

7.94

7.92

0.3

0.02

SATISFACTORY

20

PORT SIDE

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

PORT SIDE

7.94

8.25

-3.9

-0.31

SATISFACTORY

20

PORT SIDE

7.94

7.44

6.3

0.50

SATISFACTORY

20

PORT SIDE

19.10

19.03

0.4

0.07

SATISFACTORY

20

PORT SIDE

19.10

19.00

0.5

0.10

SATISFACTORY

20

PORT SIDE

6.35

8.30

-30.7

-1.95

SATISFACTORY

20

PORT SIDE

6.35

7.90

-24.4

-1.55

SATISFACTORY

20

PORT SIDE

6.35

8.21

-29.3

-1.86

SATISFACTORY

20

PORT SIDE

6.35

8.36

-31.7

-2.01

SATISFACTORY

20

PORT SIDE

6.35

8.94

-40.8

-2.59

SATISFACTORY

20

PORT SIDE

6.35

8.65

-36.2

-2.30

SATISFACTORY

20

PORT SIDE

6.35

8.10

-27.6

-1.75

SATISFACTORY

20

PORT SIDE

6.35

9.40

-48.0

-3.05

SATISFACTORY

20

PORT SIDE

19.10

19.00

0.5

0.10

SATISFACTORY

20

PORT SIDE

19.10

19.20

-0.5

-0.10

SATISFACTORY

20

PORT SIDE

7.94

7.92

0.3

0.02

SATISFACTORY

20

PORT SIDE

7.94

7.91

0.4

0.03

SATISFACTORY

20

PORT SIDE

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

PORT SIDE

7.94

8.94

-12.6

-1.00

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

CENTER LINE TO PORT & STARBOARD SIDE - VOID TANK 13C MAIN
DECK LEVEL 62 TO 67 - FRAME 38 TO 37

Drawing Ref: OES-15-162-UT13

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

67
68
69
70
81
82
83
84
85
86

PORT SIDE

7.94

8.32

-4.8

-0.38

SATISFACTORY

20

PORT SIDE

7.94

8.04

-1.3

-0.10

SATISFACTORY

20

PORT SIDE

7.94

7.72

2.8

0.22

SATISFACTORY

20

91W
91F
92W
92F
93W
93F
94W
94F
95W
95F
96W
96F
97W
97F
98W
98F
99W
99F
100W
100F

PORT SIDE

7.94

9.00

-13.4

-1.06

SATISFACTORY

20

PORT SIDE

19.10

18.41

3.6

0.69

SATISFACTORY

20

PORT SIDE

19.10

18.50

3.1

0.60

SATISFACTORY

20

PORT SIDE

19.10

18.52

3.0

0.58

SATISFACTORY

20

PORT SIDE

19.10

18.52

3.0

0.58

SATISFACTORY

20

PORT SIDE

6.35

6.15

3.1

0.20

SATISFACTORY

20

PORT SIDE

6.35

5.77

9.1

0.58

SATISFACTORY

20

PORT SIDE

7.00

6.63

5.3

0.37

SATISFACTORY

20

PORT SIDE

7.00

6.51

7.0

0.49

SATISFACTORY

20

PORT SIDE

7.00

6.80

2.9

0.20

SATISFACTORY

20

PORT SIDE

7.00

6.70

4.3

0.30

SATISFACTORY

20

PORT SIDE

7.00

6.80

2.9

0.20

SATISFACTORY

20

PORT SIDE

7.00

6.12

12.6

0.88

SATISFACTORY

20

PORT SIDE

7.00

6.38

8.9

0.62

SATISFACTORY

20

PORT SIDE

7.00

6.16

12.0

0.84

SATISFACTORY

20

PORT SIDE

7.00

6.54

6.6

0.46

SATISFACTORY

20

PORT SIDE

7.00

6.32

9.7

0.68

SATISFACTORY

20

PORT SIDE

7.00

6.30

10.0

0.70

SATISFACTORY

20

PORT SIDE

7.00

6.62

5.4

0.38

SATISFACTORY

20

PORT SIDE

7.00

6.40

8.6

0.60

SATISFACTORY

20

PORT SIDE

7.00

6.42

8.3

0.58

SATISFACTORY

20

PORT SIDE

7.00

6.88

1.7

0.12

SATISFACTORY

20

PORT SIDE

7.00

6.90

1.4

0.10

SATISFACTORY

20

PORT SIDE

7.00

6.20

11.4

0.80

SATISFACTORY

20

PORT SIDE

7.00

7.50

-7.1

-0.50

SATISFACTORY

20

PORT SIDE

7.00

7.00

0.0

0.00

SATISFACTORY

20

PORT SIDE

7.00

6.82

2.6

0.18

SATISFACTORY

20

Stiffeners

Page 2 of 2

PORT
17

FRAME 35

16

15

14

13

14

10

55

12

11

10

09

08

07

24

20

06

05

36

30

04

03

02

01

STBD

CL

46

40

50

13

23

35

45

15

25

34

44

TANK TOP

56
FRAME 36
LEVEL 67

CENTER LINE NON W/T BULKHEAD

INBOARD SHELL

16

26

33

43

12

22

32

42

LEVEL 62
FRAME 36

51

53

19

29

39

49

11

21

31

41

18

28

38

48

TANK BOTTOM

FRAME 35

52

54

LEVEL 62

FRAME 18 PORT SIDE

AFT SHELL

17

27

37

47

LEVEL 67

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

CENTER LINE TO PORT SIDE - VOID


TANK 13C MAIN DECK LEVEL 62 TO 67 FRAME 36 TO 35

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT14

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

CENTER LINE TO PORT & STARBOARD SIDE - VOID TANK 13C MAIN
DECK LEVEL 62 TO 67 - FRAME 36 TO 35

AREA IDENTIFICATION
Point Number
1
2
11
12
21
22
31
32
41
42
3
4
5
6
7
8
13
14
15
16
17
18
23
24
25
26
27
28
33
34
35
36
37
38
43
44

Drawing Ref: OES-15-162-UT15

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PORT SIDE

19.1

19.32

-1.2

-0.22

SATISFACTORY

15

PORT SIDE

19.1

19.38

-1.5

-0.28

SATISFACTORY

15

PORT SIDE

11.12

11.33

-1.9

-0.21

SATISFACTORY

15

PORT SIDE

11.12

11.57

-4.0

-0.45

SATISFACTORY

15

PORT SIDE

9.53

9.52

0.1

0.01

SATISFACTORY

15

PORT SIDE

9.53

9.58

-0.5

-0.05

SATISFACTORY

15

PORT SIDE

7.94

6.97

12.2

0.97

SUBSTANTIAL

15

PORT SIDE

7.94

8.04

-1.3

-0.10

SATISFACTORY

15

PORT SIDE

7.94

6.94

12.6

1.00

SUBSTANTIAL

15

PORT SIDE

7.94

7.83

1.4

0.11

SATISFACTORY

15

PORT SIDE

12.7

12.84

-1.1

-0.14

SATISFACTORY

20

PORT SIDE

12.7

13.1

-3.1

-0.40

SATISFACTORY

20

PORT SIDE

7.94

7.77

2.1

0.17

SATISFACTORY

20

PORT SIDE

7.94

7.88

0.8

0.06

SATISFACTORY

20

PORT SIDE

12.7

12.71

-0.1

-0.01

SATISFACTORY

20

PORT SIDE

12.7

12.92

-1.7

-0.22

SATISFACTORY

20

PORT SIDE

6.35

8.04

-26.6

-1.69

SATISFACTORY

20

PORT SIDE

6.35

7.88

-24.1

-1.53

SATISFACTORY

20

PORT SIDE

7.94

7.88

0.8

0.06

SATISFACTORY

20

PORT SIDE

7.94

8.19

-3.1

-0.25

SATISFACTORY

20

PORT SIDE

7.94

8.34

-5.0

-0.40

SATISFACTORY

20

PORT SIDE

7.94

6.98

12.1

0.96

SATISFACTORY

20

PORT SIDE

6.35

8.1

-27.6

-1.75

SATISFACTORY

20

PORT SIDE

6.35

7.91

-24.6

-1.56

SATISFACTORY

20

PORT SIDE

7.94

8.15

-2.6

-0.21

SATISFACTORY

20

PORT SIDE

7.94

7.77

2.1

0.17

SATISFACTORY

20

PORT SIDE

7.94

8.01

-0.9

-0.07

SATISFACTORY

20

PORT SIDE

7.94

8.04

-1.3

-0.10

SATISFACTORY

20

PORT SIDE

6.35

7.83

-23.3

-1.48

SATISFACTORY

20

PORT SIDE

6.35

7.95

-25.2

-1.60

SATISFACTORY

20

PORT SIDE

7.94

7.71

2.9

0.23

SATISFACTORY

20

PORT SIDE

7.94

8.28

-4.3

-0.34

SATISFACTORY

20

PORT SIDE

7.94

8.1

-2.0

-0.16

SATISFACTORY

20

PORT SIDE

7.94

8.1

-2.0

-0.16

SATISFACTORY

20

PORT SIDE

6.35

7.98

-25.7

-1.63

SATISFACTORY

20

PORT SIDE

6.35

8.07

-27.1

-1.72

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

CENTER LINE TO PORT & STARBOARD SIDE - VOID TANK 13C MAIN
DECK LEVEL 62 TO 67 - FRAME 36 TO 35

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

45
46
47
48
51
52
53
54
55
56

PORT SIDE

7.94

7.92

PORT SIDE

7.94

8.21

PORT SIDE

7.94

8.13

PORT SIDE

7.94

PORT SIDE

9W
9F
10W
10F
19W
19F
20W
20F
29W
29F
30W
30F
39W
39F
40W
40F
49W
49F
50W
50F

Gauged Diminution
(%)

Drawing Ref: OES-15-162-UT15

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

0.3

0.02

SATISFACTORY

20

-3.4

-0.27

SATISFACTORY

20

-2.4

-0.19

SATISFACTORY

20

8.04

-1.3

-0.10

SATISFACTORY

20

15.88

16.56

-4.3

-0.68

SATISFACTORY

20

PORT SIDE

15.88

16.58

-4.4

-0.70

SATISFACTORY

20

PORT SIDE

15.88

16.47

-3.7

-0.59

SATISFACTORY

20

PORT SIDE

15.88

16.43

-3.5

-0.55

SATISFACTORY

20

PORT SIDE

7.94

7.45

6.2

0.49

SATISFACTORY

20

PORT SIDE

7.94

6.79

14.5

1.15

SATISFACTORY

20

PORT SIDE

7.0

6.88

1.7

0.12

SATISFACTORY

20

PORT SIDE

7.0

6.59

5.9

0.41

SATISFACTORY

20

PORT SIDE

7.0

6.55

6.4

0.45

SATISFACTORY

20

PORT SIDE

7.0

6.35

9.3

0.65

SATISFACTORY

20

PORT SIDE

7.0

6.88

1.7

0.12

SATISFACTORY

20

PORT SIDE

7.0

6.44

8.0

0.56

SATISFACTORY

20

PORT SIDE

7.0

6.5

7.1

0.50

SATISFACTORY

20

PORT SIDE

7.0

6.13

12.4

0.87

SATISFACTORY

20

PORT SIDE

7.0

6.16

12.0

0.84

SATISFACTORY

20

PORT SIDE

7.0

5.99

14.4

1.01

SATISFACTORY

20

PORT SIDE

7.0

6.53

6.7

0.47

SATISFACTORY

20

PORT SIDE

7.0

6.2

11.4

0.80

SATISFACTORY

20

PORT SIDE

7.0

6.38

8.9

0.62

SATISFACTORY

20

PORT SIDE

7.0

6.16

12.0

0.84

SATISFACTORY

20

PORT SIDE

7.0

6.46

7.7

0.54

SATISFACTORY

20

PORT SIDE

7.0

6.31

9.9

0.69

SATISFACTORY

20

PORT SIDE

7.0

6.31

9.9

0.69

SATISFACTORY

20

PORT SIDE

7.0

5.97

14.7

1.03

SATISFACTORY

20

PORT SIDE

7.0

0.0

0.00

SATISFACTORY

20

PORT SIDE

7.0

6.22

11.1

0.78

SATISFACTORY

20

Stiffeners

Page 2 of 2

PORT
17

FRAME 34

16

15

14

13

16

10

55

12

11

10

09

08

07

26

20

06

05

36

30

04

03

02

01

STBD

CL

46

40

50

15

25

35

45

14

24

34

44

TANK TOP

56
FRAME 33
LEVEL 67

CENTER LINE NON W/T BULKHEAD

INBOARD SHELL

13

23

33

43

12

22

32

42

LEVEL 62
FRAME 33

51

53

19

29

39

49

11

21

31

41

18

28

38

48

TANK BOTTOM

FRAME 34

52

54

LEVEL 62

FRAME 18 PORT SIDE

AFT SHELL

17

27

37

47

LEVEL 67

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

CENTER LINE TO PORT SIDE - VOID


TANK 13C MAIN DECK LEVEL 62 TO 67 FRAME 34 TO 33

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT16

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

CENTER LINE TO PORT & STARBOARD SIDE - VOID TANK 13C MAIN
DECK LEVEL 62 TO 67 - FRAME 34 TO 33

AREA IDENTIFICATION

Drawing Ref: OES-15-162-UT17

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PORT SIDE
PORT SIDE
PORT SIDE
PORT SIDE
PORT SIDE
PORT SIDE
PORT SIDE
PORT SIDE
PORT SIDE
PORT SIDE

19.10
19.10
11.12
11.12
9.53
9.53
7.94
7.94
7.94
7.94

19.50
19.50
11.11
11.16
9.34
9.65
8.60
8.36
7.71
7.65

-2.1
-2.1
0.1
-0.4
2.0
-1.3
-8.3
-5.3
2.9
3.7

-0.40
-0.40
0.01
-0.04
0.19
-0.12
-0.66
-0.42
0.23
0.29

SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY
SATISFACTORY

15
15
15
15
15
15
15
15
15
15

PORT SIDE

19.10

19.50

-2.1

-0.40

SATISFACTORY

20

PORT SIDE

19.10

19.28

-0.9

-0.18

SATISFACTORY

20

PORT SIDE

7.94

8.03

-1.1

-0.09

SATISFACTORY

20

Point Number
1
2
11
12
21
22
31
32
41
42

3
4
5
6
7
8
13
14
15
16
17
18
23
24
25
26
27
28
33
34
35
36
37
38
43
44

PORT SIDE

7.94

7.75

2.4

0.19

SATISFACTORY

20

PORT SIDE

12.70

12.87

-1.3

-0.17

SATISFACTORY

20

PORT SIDE

12.70

12.88

-1.4

-0.18

SATISFACTORY

20

PORT SIDE

19.10

19.52

-2.2

-0.42

SATISFACTORY

20

PORT SIDE

19.10

19.34

-1.3

-0.24

SATISFACTORY

20

PORT SIDE

7.94

7.62

4.0

0.32

SATISFACTORY

20

PORT SIDE

7.94

7.65

3.7

0.29

SATISFACTORY

20

PORT SIDE

7.94

7.71

2.9

0.23

SATISFACTORY

20

PORT SIDE

7.94

7.68

3.3

0.26

SATISFACTORY

20

PORT SIDE

9.53

9.77

-2.5

-0.24

SATISFACTORY

20

PORT SIDE

9.53

9.43

1.0

0.10

SATISFACTORY

20

PORT SIDE

7.94

8.02

-1.0

-0.08

SATISFACTORY

20

PORT SIDE

7.94

7.79

1.9

0.15

SATISFACTORY

20

PORT SIDE

7.94

7.75

2.4

0.19

SATISFACTORY

20

PORT SIDE

7.94

7.66

3.5

0.28

SATISFACTORY

20

PORT SIDE

9.53

9.49

0.4

0.04

SATISFACTORY

20

PORT SIDE

9.53

9.37

1.7

0.16

SATISFACTORY

20

PORT SIDE

7.94

7.62

4.0

0.32

SATISFACTORY

20

PORT SIDE

7.94

6.65

16.2

1.29

SUBSTANTIAL

20

PORT SIDE

6.35

6.62

-4.3

-0.27

SATISFACTORY

20

PORT SIDE

6.35

6.68

-5.2

-0.33

SATISFACTORY

20

PORT SIDE

9.53

9.46

0.7

0.07

SATISFACTORY

20

PORT SIDE

9.53

9.38

1.6

0.15

SATISFACTORY

20

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: Jaunary 2015

Report Number: 2015-162R

CENTER LINE TO PORT & STARBOARD SIDE - VOID TANK 13C MAIN
DECK LEVEL 62 TO 67 - FRAME 34 TO 33

Drawing Ref: OES-15-162-UT17

AREA IDENTIFICATION

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

45
46
47
48
51
52
53
54
55
56

PORT SIDE

7.94

7.74

2.5

0.20

SATISFACTORY

20

PORT SIDE

7.94

7.62

4.0

0.32

SATISFACTORY

20

PORT SIDE

7.94

7.68

3.3

0.26

SATISFACTORY

20

PORT SIDE

7.94

7.62

4.0

0.32

SATISFACTORY

20

PORT SIDE

19.10

19.43

-1.7

-0.33

SATISFACTORY

20

PORT SIDE

19.10

19.49

-2.0

-0.39

SATISFACTORY

20

PORT SIDE

19.10

19.35

-1.3

-0.25

SATISFACTORY

20

PORT SIDE

19.10

19.50

-2.1

-0.40

SATISFACTORY

20

PORT SIDE

6.35

6.37

-0.3

-0.02

SATISFACTORY

20

PORT SIDE

6.35

6.55

-3.1

-0.20

SATISFACTORY

20

9W
9F
10W
10F
19W
19F
20W
20F
29W
29F
30W
30F
39W
39F
40W
40F
49W
49F
50W
50F

PORT SIDE

7.00

6.16

12.0

0.84

SATISFACTORY

20

PORT SIDE

7.00

5.98

14.6

1.02

SATISFACTORY

20

PORT SIDE

7.00

6.44

8.0

0.56

SATISFACTORY

20

PORT SIDE

7.00

6.32

9.7

0.68

SATISFACTORY

20

PORT SIDE

7.00

6.87

1.9

0.13

SATISFACTORY

20

PORT SIDE

7.00

6.52

6.9

0.48

SATISFACTORY

20

PORT SIDE

7.00

6.60

5.7

0.40

SATISFACTORY

20

PORT SIDE

7.00

6.34

9.4

0.66

SATISFACTORY

20

PORT SIDE

7.00

7.15

-2.1

-0.15

SATISFACTORY

20

PORT SIDE

7.00

6.97

0.4

0.03

SATISFACTORY

20

PORT SIDE

7.00

6.46

7.7

0.54

SATISFACTORY

20

PORT SIDE

7.00

6.61

5.6

0.39

SATISFACTORY

20

PORT SIDE

7.00

6.78

3.1

0.22

SATISFACTORY

20

PORT SIDE

7.00

6.32

9.7

0.68

SATISFACTORY

20

PORT SIDE

7.00

6.84

2.3

0.16

SATISFACTORY

20

PORT SIDE

7.00

7.15

-2.1

-0.15

SATISFACTORY

20

PORT SIDE

7.00

6.46

7.7

0.54

SATISFACTORY

20

PORT SIDE

7.00

6.30

10.0

0.70

SATISFACTORY

20

PORT SIDE

7.00

6.51

7.0

0.49

SATISFACTORY

20

PORT SIDE

7.00

6.30

10.0

0.70

SATISFACTORY

20

Stiffeners

Page 2 of 2

&HQWHU/LQH3RUW6LGH&0DLQ'HFN

CL

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17 BHD

21

19

20

21

22

23 BHD

25

11

26

27

28 BHD

FR - 41

FRAME 40

FR - 40

TANK TOP

9
22

12

10

FRAME 41
BULKHEAD AT 59' 2" FROM CENTER LINE

LEVEL 67

FR - 41

23

13

24

14

FR - 40

OUTBOARD SHELL

19

20

LEVEL 62
FRAME 41

25

15

BULKHEAD AT 49' 2" FROM CENTER LINE

5
FR - 41

TANK BOTTOM

26

16

FR - 40

FRAME 40
LEVEL 62
36' OFF C/L

27

49' 2" OFF C/L

29

30

59' 2" OFF C/L

17

INBOARD SHELL

BULKHEAD AT 36' FROM CENTER LINE

28

18

LEVEL 67

STIFFENERS AT EQUALLY SPACED AT 24 INCHES

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : JANUARY 2015

SCALE: NOT TO SCALE

REVISION

CENTER LINE TO PORT SIDE - VOID TANK


14C MAIN DECK LEVEL 62 TO 67

INSPECTOR

T. MCGREGOR / R. LIMA / N. CORTIGNOLA /


C. EDUARDO

DRAWN BY

RANGANA SENAPATHI

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-162

UT10

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
VOID TANK 14C MAIN DECK LEVEL 62 TO 67

Date: Jaunary 2015

Report Number: 2015-162R

CENTER LINE TO PORT SIDE & STARBOARD SIDE

AREA IDENTIFICATION
Point Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Drawing Ref: OES-15-162-UT11

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PORT SIDE

6.35

6.08

4.3

0.27

SATISFACTORY

20

PORT SIDE

6.35

6.08

4.3

0.27

SATISFACTORY

20

PORT SIDE

9.53

9.550

-0.2

-0.02

SATISFACTORY

15

PORT SIDE

9.53

9.560

-0.4

-0.04

SATISFACTORY

15

PORT SIDE

7.93

7.930

0.0

0.00

SATISFACTORY

15

PORT SIDE

7.93

7.930

0.0

0.00

SATISFACTORY

15

PORT SIDE

9.525

9.58

-0.6

-0.05

SATISFACTORY

20

PORT SIDE

9.525

9.84

-3.3

-0.32

SATISFACTORY

20

PORT SIDE

19.05

19.200

-0.8

-0.15

SATISFACTORY

15

PORT SIDE

19.05

19.55

-2.6

-0.50

SATISFACTORY

15

PORT SIDE

6.35

6.08

4.3

0.27

SATISFACTORY

20

PORT SIDE

6.35

6.05

4.7

0.30

SATISFACTORY

20

PORT SIDE

9.53

9.500

0.3

0.03

SATISFACTORY

15

PORT SIDE

9.53

9.490

0.4

0.04

SATISFACTORY

15

PORT SIDE

7.93

7.630

3.8

0.30

SATISFACTORY

15

PORT SIDE

7.93

7.630

3.8

0.30

SATISFACTORY

15

PORT SIDE

9.525

9.8

-2.9

-0.28

SATISFACTORY

20

PORT SIDE

9.525

9.55

-0.3

-0.03

SATISFACTORY

20

PORT SIDE

19.05

19.58

-2.8

-0.53

SATISFACTORY

20

PORT SIDE

19.05

19.61

-2.9

-0.56

SATISFACTORY

20

PORT SIDE

6.35

6.14

3.3

0.21

SATISFACTORY

20

PORT SIDE

6.35

6.18

2.7

0.17

SATISFACTORY

20

PORT SIDE

9.53

9.520

0.1

0.01

SATISFACTORY

15

PORT SIDE

9.53

9.730

-2.2

-0.21

SATISFACTORY

15

PORT SIDE

7.93

8.300

-4.7

-0.37

SATISFACTORY

15

PORT SIDE

7.93

8.200

-3.4

-0.27

SATISFACTORY

15

PORT SIDE

9.525

9.3

2.4

0.23

SATISFACTORY

20

PORT SIDE

9.525

9.31

2.3

0.22

SATISFACTORY

20

PORT SIDE

9.525

9.5

0.3

0.03

SATISFACTORY

20

PORT SIDE

9.525

9.27

2.7

0.26

SATISFACTORY

20

Page 1 of 1

Pontoon Ballast Tank Drawings

:DWHU%DOODVW7DQN%6WDUERDUG

FWD

AFT

TANK TOP

PLATE A

5
WELD

PLATE B

WELD

PLATE C

WELD

FR-1

PROJECT : ULTRASONIC THICKNESS GAUGING

SCALE: NOT TO SCALE

REVISION

FR-2

SIDE SHELL INBOARD

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

PLATE D

TANK TOP PLATING-WATER BALLAST 1B


(PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT03

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TANK TOP PLATING-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT03

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
PLATE C
1
2
3
4
5
PLATE D
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

25.90

25.10

3.1

0.80

SATISFACTORY

15

PLATING

25.90

25.20

2.7

0.70

SATISFACTORY

15

PLATING

25.90

25.20

2.7

0.70

SATISFACTORY

15

PLATING

25.90

25.20

2.7

0.70

SATISFACTORY

15

PLATING

25.90

25.20

2.7

0.70

SATISFACTORY

15

PLATING

12.00

11.50

4.2

0.50

SATISFACTORY

15

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

PLATING

12.00

12.20

-1.7

-0.20

SATISFACTORY

15

PLATING

12.00

12.20

-1.7

-0.20

SATISFACTORY

15

PLATING

12.00

12.20

-1.7

-0.20

SATISFACTORY

15

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

PLATING

12.00

12.20

-1.7

-0.20

SATISFACTORY

15

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

Page 1 of 1

FWD

AFT

LONGITUDINAL CENTERLINE BHD


TANK TOP

PLATE A
6

7
WELD

PLATE B

WELD

7
PLATE C

WELD

7
PLATE D

FR-1

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-2

SIDE SHELL INBOARD

TANK TOP STIFFENERS-WATER BALLAST 1B


(PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT04

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TANK TOP STIFFENERS-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT04

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F
PLATE D
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

STIFFENER

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

STIFFENER

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

STIFFENER

10.00

10.50

-5.0

-0.50

SATISFACTORY

25

STIFFENER

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

STIFFENER

10.00

10.70

-7.0

-0.70

SATISFACTORY

25

STIFFENER

10.00

10.30

-3.0

-0.30

SATISFACTORY

25

STIFFENER

10.00

10.70

-7.0

-0.70

SATISFACTORY

25

STIFFENER

10.00

10.30

-3.0

-0.30

SATISFACTORY

25

Page 1 of 1

FWD

AFT

LONGITUDINAL CENTERLINE BHD


TANK TOP

PLATE A

5
WELD

PLATE B

5
WELD

PLATE C

FR-1

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-2

SIDE SHELL INBOARD

BOTTOM TANK PLATING-WATER BALLAST 1B


(PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT05

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

BOTTOM TANK PLATING-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT05

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.70

12.50

1.6

0.20

SATISFACTORY

15

PLATING

12.70

12.40

2.4

0.30

SATISFACTORY

15

PLATING

12.70

12.50

1.6

0.20

SATISFACTORY

15

PLATING

12.70

12.40

2.4

0.30

SATISFACTORY

15

PLATING

12.70

12.40

2.4

0.30

SATISFACTORY

15

PLATING

12.70

12.20

3.9

0.50

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

Page 1 of 1

FWD

AFT

LONGITUDINAL CENTERLINE BHD


TANK TOP

PLATE A

WELD

PLATE B

WELD

PLATE C

SIDE SHELL INBOARD

FR-1

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

BOTTOM TANK STIFFENERS-WATER BALLAST


1B (PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

FR-2

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT06

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

BOTTOM TANK STIFFENERS-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT06

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F
PLATE D
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

STIFFENER

12.00

12.30

-2.5

-0.30

SATISFACTORY

25

STIFFENER

15.90

15.70

1.3

0.20

SATISFACTORY

25

STIFFENER

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

STIFFENER

15.90

15.90

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

12.30

-2.5

-0.30

SATISFACTORY

25

STIFFENER

15.90

15.70

1.3

0.20

SATISFACTORY

25

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

15.90

15.80

0.6

0.10

SATISFACTORY

25

STIFFENER

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

STIFFENER

15.90

15.80

0.6

0.10

SATISFACTORY

25

STIFFENER

12.00

12.30

-2.5

-0.30

SATISFACTORY

25

STIFFENER

15.90

15.90

0.0

0.00

SATISFACTORY

25

Page 1 of 1

R/S

ABS Wastage
Allowance (%)

PORT

STBD

TANK TOP

PLATE C

2
WELD

PLATE B

WELD
4

PLATE A

TANK BOTTOM

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

TRANSVERSE WATERTIGHT BULKHEAD 0


PLATING-WATER BALLAST 1B (PONTOON)
STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT07

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WATERTIGHT BULKHEAD 0 PLATING-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT07

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATING

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

Page 1 of 1

PORT

STBD

TANK TOP

PLATE C
6

WELD

PLATE B
6

WELD

PLATE A
6

TANK BOTTOM

TRANSVERSE WATERTIGHT BULKHEAD 0


DESCRIPTION /
STIFFENERS-WATER BALLAST 1B (PONTOON)
LOCATION
STARBOARD

PROJECT : ULTRASONIC THICKNESS GAUGING


INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT08

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WATERTIGHT BULKHEAD 0 STIFFENERS-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT08

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

Page 1 of 1

AFT

FWD

TANK TOP

PLATE C

1
WELD

PLATE B

WELD

PLATE A

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-1

TANK BOTTOM

FR-2

INBOARD SIDE SHELL PLATING-WATER


BALLAST 1B (PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT09

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

INBOARD SIDE SHELL PLATING-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT09

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.00

12.50

-4.2

-0.50

SATISFACTORY

15

PLATING

12.00

12.50

-4.2

-0.50

SATISFACTORY

15

PLATING

12.00

12.50

-4.2

-0.50

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.50

-4.2

-0.50

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

Page 1 of 1

AFT

FWD

TANK TOP

PLATE C
6

WELD

PLATE B

WELD

PLATE A

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-1

TANK BOTTOM

FR-2

INBOARD SIDE SHELL STIFFENERS-WATER


BALLAST 1B (PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT10

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

INBOARD SIDE SHELL STIFFENERS-WATER BALLAST 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT10

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

Page 1 of 1

PORT
WS-5

STBD

WS-6

TANK TOP

WEB FRAMING C

8
1

B4

B3

WS-4

WS-7

WEB FRAMING B

WEB FRAMING D

WS-3

WS-8

B2
7

B1
8

WEB FRAMING A
7

WS-2

WS-1

TANK BOTTOM

TRANSVERSE WEB PLATING FRAME 1-WATER


DESCRIPTION /
BALLAST TANK 1B (PONTOON) STARBOARD
LOCATION

PROJECT : ULTRASONIC THICKNESS GAUGING


INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT11

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WEB PLATING FRAME 1-WATER BALLAST TANK 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT11

AREA IDENTIFICATION
WEB FRAMING A
1
2
3
4
5
6
7
8
WEB FRAMING B
1
2
3
4
5
6
7
8
WEB FRAMING C
1
2
3
4
5
6
7
8
WEB FRAMING D
1
2
3
4
5
6
7
8

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

WEB FRAME

15.90

16.00

-0.6

-0.10

SATISFACTORY

25

WEB FRAME

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

WEB FRAME

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

WEB FRAME

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

WEB FRAME

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

WEB FRAME

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

WEB FRAME

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

WEB FRAME

15.90

16.20

-1.9

-0.30

SATISFACTORY

25

WEB FRAME

14.00

14.10

-0.7

-0.10

SATISFACTORY

25

WEB FRAME

14.00

14.10

-0.7

-0.10

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.10

-0.7

-0.10

SATISFACTORY

25

WEB FRAME

14.00

14.10

-0.7

-0.10

SATISFACTORY

25

WEB FRAME

14.00

13.90

0.7

0.10

SATISFACTORY

25

WEB FRAME

14.00

13.90

0.7

0.10

SATISFACTORY

25

WEB FRAME

14.00

14.10

-0.7

-0.10

SATISFACTORY

25

WEB FRAME

14.00

14.10

-0.7

-0.10

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

13.80

1.4

0.20

SATISFACTORY

25

WEB FRAME

14.00

13.80

1.4

0.20

SATISFACTORY

25

WEB FRAME

14.00

13.80

1.4

0.20

SATISFACTORY

25

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WEB PLATING FRAME 1-WATER BALLAST TANK 1B (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT11

AREA IDENTIFICATION
WEB FRAMING STIFFENER
WS-1
WS-2
WS-3
WS-4
WS-5
WS-6
WS-7
WS-8
WEB FRAME BRACKETS
1
2
3
4

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

FRAME STIFFENER

15.90

16.60

-4.4

-0.70

SATISFACTORY

25

FRAME STIFFENER

15.90

16.50

-3.8

-0.60

SATISFACTORY

25

FRAME STIFFENER

14.00

14.00

0.0

0.00

SATISFACTORY

25

FRAME STIFFENER

14.00

13.80

1.4

0.20

SATISFACTORY

25

FRAME STIFFENER

14.00

13.70

2.1

0.30

SATISFACTORY

25

FRAME STIFFENER

14.00

14.00

0.0

0.00

SATISFACTORY

25

FRAME STIFFENER

14.00

14.00

0.0

0.00

SATISFACTORY

25

FRAME STIFFENER

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

FRMAE BRACKET

12.70

12.90

-1.6

-0.20

SATISFACTORY

25

FRMAE BRACKET

12.70

12.70

0.0

0.00

SATISFACTORY

25

FRMAE BRACKET

12.70

12.80

-0.8

-0.10

SATISFACTORY

25

FRMAE BRACKET

14.00

12.80

8.6

1.20

SATISFACTORY

25

Page 2 of 2

Water Ballast Tank B - Port

AFT

FWD

TANK TOP

LONGITUDINAL CENTERLINE BHD

PLATE A

5
WELD

PLATE B

5
WELD

PLATE C

FR-30

PROJECT : ULTRASONIC THICKNESS GAUGING

SCALE: NOT TO SCALE

REVISION

FR-29

SIDE SHELL INBOARD

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

BOTTOM TANK PLATING - WATER BALLAST


TANK 8B(PONTOON) PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT01

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

BOTTOM TANK PLATING - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT01

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.20

-1.4

-0.20

SATISFACTORY

15

PLATING

14.00

14.20

-1.4

-0.20

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.20

-1.4

-0.20

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.40

-2.9

-0.40

SATISFACTORY

15

Page 1 of 1

AFT

FWD

TANK TOP

LONGITUDINAL CENTERLINE BHD

PLATE A

WELD

PLATE B

WELD

PLATE C

FR-30

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-29

SIDE SHELL INBOARD

BOTTOM TANK STIFFENERS - WATER


BALLAST TANK 8B(PONTOON) PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT02

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

BOTTOM TANK STIFFENERS - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT02

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

STIFFENER

12.00

11.90

STIFFENER

15.90

16.00

STIFFENER

12.00

12.00

STIFFENER

15.90

STIFFENER
STIFFENER

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

0.8

0.10

SATISFACTORY

25

-0.6

-0.10

SATISFACTORY

25

0.0

0.00

SATISFACTORY

25

16.00

-0.6

-0.10

SATISFACTORY

25

12.00

12.00

0.0

0.00

SATISFACTORY

25

15.90

15.90

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

15.90

16.00

-0.6

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

15.90

16.00

-0.6

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

15.90

16.00

-0.6

-0.10

SATISFACTORY

25

Page 1 of 1

Gauged Diminution
(%)

PORT

STBD

TANK TOP

PLATE C

WELD

PLATE B

PLATE A

WELD

TANK BOTTOM

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

TRANSVERSE WATERTIGHT BULKHEAD 28


PLATING-WATER BALLAST 8B (PONTOON)
PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT03

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WATERTIGHT BULKHEAD 28 PLATING-WATER BALLAST 8B (PONTOON) PORT

Drawing Ref: OES-15-391-UT03

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

Page 1 of 1

PORT

STBD

TANK TOP

PLATE C
6

WELD

7
PLATE B

WELD

PLATE A
6

TANK BOTTOM

TRANSVERSE WATERTIGHT BULKHEAD 28


DESCRIPTION /
STIFFENERS-WATER BALLAST 8B (PONTOON)
LOCATION
PORT

PROJECT : ULTRASONIC THICKNESS GAUGING


INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT04

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

BOTTOM TANK STIFFENERS - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT04

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F
PLATE D
1
2
3

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.50

4.2

0.50

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.70

12.70

0.0

0.00

SATISFACTORY

25

STIFFENER

25.40

25.40

0.0

0.00

SATISFACTORY

25

STIFFENER

25.40

25.40

0.0

0.00

SATISFACTORY

25

Page 1 of 1

R/S

ABS Wastage
Allowance (%)

AFT

FWD

TANK TOP

LONGITUDINAL CENTERLINE BHD

PLATE A

WELD

PLATE B

WELD
1

FR-30

PROJECT : ULTRASONIC THICKNESS GAUGING

SCALE: NOT TO SCALE

REVISION

FR-29

SIDE SHELL INBOARD

DESCRIPTION / TANK TOP PLATING - WATER BALLAST TANK


LOCATION
8B(PONTOON) PORT

INSPECTION DATE : MARCH 2015

PLATE C

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT05

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TANK TOP PLATING - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT05

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.60

-5.0

-0.60

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.60

-5.0

-0.60

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

Page 1 of 1

AFT

FWD

TANK TOP

LONGITUDINAL CENTERLINE BHD

PLATE A

WELD

PLATE B

WELD

PLATE C

FR-30

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-29

SIDE SHELL INBOARD

TANK TOP STIFFENERS - WATER BALLAST


TANK 8B(PONTOON) PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT06

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TANK TOP STIFFENERS - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT06

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

STIFFENER

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

STIFFENER

10.00

10.00

0.0

0.00

SATISFACTORY

25

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

STIFFENER

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

STIFFENER

10.00

10.30

-3.0

-0.30

SATISFACTORY

25

STIFFENER

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

STIFFENER

10.00

10.20

-2.0

-0.20

SATISFACTORY

25

STIFFENER

10.00

10.30

-3.0

-0.30

SATISFACTORY

25

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

STIFFENER

10.00

10.30

-3.0

-0.30

SATISFACTORY

25

STIFFENER

10.00

10.20

-2.0

-0.20

SATISFACTORY

25

Page 1 of 1

AFT

FWD

TANK TOP

PLATE C

2
WELD

PLATE B

WELD

PLATE A

FR-30

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-29

TANK BOTTOM

LONGITUDINAL CENTERLINE WATERTIGHT


BHD PLATING - WATER BALLAST TANK
8B(PONTOON) PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT07

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

LONGITUDINAL CENTERLINE WATERTIGHT BHD PLATING - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT07

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATING

12.00

11.70

2.5

0.30

SATISFACTORY

25

PLATING

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATING

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATING

12.00

11.80

1.7

0.20

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

11.90

0.8

0.10

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

Page 1 of 1

AFT

FWD

TANK TOP

PLATE C
6

WELD

PLATE B
6

WELD

7
PLATE A

FR-30

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-29

TANK BOTTOM

LONGITUDINAL CENTERLINE WATERTIGHT


BHD STIFFENERS - WATER BALLAST TANK
8B(PONTOON) PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT08

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

LONGITUDINAL CENTERLINE WATERTIGHT BHD STIFFENERS - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT08

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.50

4.2

0.50

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.50

4.2

0.50

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

Page 1 of 1

FWD

AFT

TANK TOP

PLATE C

2
WELD

PLATE B

WELD
4

PLATE A

FR-29

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-30

TANK BOTTOM

INBOARD SIDE SHELL PLATING - WATER


BALLAST TANK 8B(PONTOON) PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT09

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

LONGITUDINAL CENTERLINE WATERTIGHT BHD PLATING - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT09

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE C
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.60

0.8

0.10

SATISFACTORY

15

PLATING

12.70

12.60

0.8

0.10

SATISFACTORY

15

PLATING

12.70

12.60

0.8

0.10

SATISFACTORY

15

PLATING

12.70

12.60

0.8

0.10

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

PLATING

12.70

12.70

0.0

0.00

SATISFACTORY

15

Page 1 of 1

FWD

AFT

TANK TOP

PLATE C
6

WELD

7
PLATE B

WELD

7
PLATE A

FR-29

DESCRIPTION / INBOARD SIDE SHELL STIFFENERS - WATER


BALLAST TANK 8B(PONTOON) PORT
LOCATION

PROJECT : ULTRASONIC THICKNESS GAUGING


INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-30

TANK BOTTOM

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT10

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

INBOARD SIDE SHELL STIFFENERS - WATER BALLAST TANK 8B(PONTOON) PORT

Drawing Ref: OES-15-391-UT10

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

Page 1 of 1

R/S

ABS Wastage
Allowance (%)

PORT
WS-5

TANK TOP

WS-6

STBD

WEB FRAMING C

8
1

B3

B4

WS-4

WS-7

WEB FRAMING B

WEB FRAMING D

WS-3

WS-8

B2
7

B1
2

WEB FRAMING A
1

WS-2

WS-1

TANK BOTTOM

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

TRANSVERSE WEB PLATING FRAME


30-WATER BALLAST TANK 8B (PONTOON)
PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT11

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WEB PLATING FRAME 30-WATER BALLAST TANK 8B (PONTOON) PORT

Drawing Ref: OES-15-391-UT11

AREA IDENTIFICATION
WEB FRAMING A
1
2
3
4
5
6
7
8
WEB FRAMING B
1
2
3
4
5
6
7
8
WEB FRAMING C
1
2
3
4
5
6
7
8
WEB FRAMING D
1
2
3
4
5
6
7
8

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

WEB FRAME

15.90

16.10

-1.3

-0.20

SATISFACTORY

25

WEB FRAME

15.90

15.90

0.0

0.00

SATISFACTORY

25

WEB FRAME

15.90

15.90

0.0

0.00

SATISFACTORY

25

WEB FRAME

15.90

15.90

0.0

0.00

SATISFACTORY

25

WEB FRAME

16.60

16.60

0.0

0.00

SATISFACTORY

25

WEB FRAME

16.60

16.60

0.0

0.00

SATISFACTORY

25

WEB FRAME

16.60

16.60

0.0

0.00

SATISFACTORY

25

WEB FRAME

16.60

16.60

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.60

-4.3

-0.60

SATISFACTORY

25

WEB FRAME

14.00

14.60

-4.3

-0.60

SATISFACTORY

25

WEB FRAME

14.00

14.50

-3.6

-0.50

SATISFACTORY

25

WEB FRAME

14.00

14.50

-3.6

-0.50

SATISFACTORY

25

WEB FRAME

14.00

14.50

-3.6

-0.50

SATISFACTORY

25

WEB FRAME

14.00

14.50

-3.6

-0.50

SATISFACTORY

25

WEB FRAME

14.00

14.50

-3.6

-0.50

SATISFACTORY

25

WEB FRAME

14.00

14.40

-2.9

-0.40

SATISFACTORY

25

WEB FRAME

14.00

13.90

0.7

0.10

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.10

-0.7

-0.10

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

Page 1 of 2

R/S

ABS Wastage
Allowance (%)

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WEB PLATING FRAME 30-WATER BALLAST TANK 8B (PONTOON) PORT

Drawing Ref: OES-15-391-UT11

AREA IDENTIFICATION
WEB FRAME STIFFENERS
1
2
3
4
5
6
7
8
WEB FRAME BRACKETS
1
2
1
2

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

FRAME SRIFFENER

15.90

16.30

-2.5

-0.40

SATISFACTORY

25

FRAME SRIFFENER

15.90

16.30

-2.5

-0.40

SATISFACTORY

25

FRAME SRIFFENER

14.00

13.90

0.7

0.10

SATISFACTORY

25

FRAME SRIFFENER

14.00

13.90

0.7

0.10

SATISFACTORY

25

FRAME SRIFFENER

14.00

14.00

0.0

0.00

SATISFACTORY

25

FRAME SRIFFENER

14.00

13.90

0.7

0.10

SATISFACTORY

25

FRAME SRIFFENER

14.00

13.90

0.7

0.10

SATISFACTORY

25

FRAME SRIFFENER

14.00

13.90

0.7

0.10

SATISFACTORY

25

FRAME BRACKET

12.70

12.70

0.0

0.00

SATISFACTORY

25

FRAME BRACKET

12.70

12.60

0.8

0.10

SATISFACTORY

25

FRAME BRACKET

12.70

12.70

0.0

0.00

SATISFACTORY

25

FRAME BRACKET

12.70

12.70

0.0

0.00

SATISFACTORY

25

Page 2 of 2

Water Ballast Tank $6WDUERDUG

FWD

AFT

SIDE SHELL OUTBOARD

PLATE A

WELD
4

FR-32

PROJECT : ULTRASONIC THICKNESS GAUGING

SCALE: NOT TO SCALE

REVISION

FR-33

LONGITUDINAL CENTERLINE BHD

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

PLATE B

BOTTOM TANK PLATING-WATER BALLAST


TANK 9A (PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT01

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

BOTTOM TANK PLATING-WATER BALLAST TANK 9A (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT01

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.20

-1.4

-0.20

SATISFACTORY

15

PLATING

14.00

14.10

-0.7

-0.10

SATISFACTORY

15

PLATING

14.00

14.20

-1.4

-0.20

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.30

-2.1

-0.30

SATISFACTORY

15

PLATING

14.00

14.50

-3.6

-0.50

SATISFACTORY

15

PLATING

14.00

14.50

-3.6

-0.50

SATISFACTORY

15

PLATING

14.00

14.50

-3.6

-0.50

SATISFACTORY

15

Page 1 of 1

FWD

AFT

SIDE SHELL OUTBOARD

PLATE A
6

WELD

PLATE B

FR-32

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION / BOTTOM TANK STIFFENERS-WATER BALLAST


LOCATION
TANK 9A (PONTOON) STARBOARD

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-33

LONGITUDINAL CENTERLINE BHD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT02

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TANK TOP STIFFENERS-WATER BALLAST TANK 9A (PONTOON) PORT

Drawing Ref: OES-15-391-UT02

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

STIFFENER

12.00

11.90

STIFFENER

15.90

16.00

STIFFENER

12.00

11.80

STIFFENER

15.90

15.90

STIFFENER

12.00

11.80

STIFFENER

15.90

16.00

STIFFENER

12.00

11.80

STIFFENER

15.90

16.70

Page 1 of 1

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

0.8

0.10

SATISFACTORY

25

-0.6

-0.10

SATISFACTORY

25

1.7

0.20

SATISFACTORY

25

0.0

0.00

SATISFACTORY

25

1.7

0.20

SATISFACTORY

25

-0.6

-0.10

SATISFACTORY

25

1.7

0.20

SATISFACTORY

25

-5.0

-0.80

SATISFACTORY

25

FWD

AFT

SIDE SHELL OUTBOARD

PLATE A

WELD
1

PLATE B

LONGITUDINAL CENTERLINE BHD

FR-18

FR-17

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

TANK TOP PLATING-WATER BALLAST TANK


9A (PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT03

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TANK TOP PLATING-WATER BALLAST TANK 9A (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT03

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.30

-2.5

-0.30

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.40

-3.3

-0.40

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

15

Page 1 of 1

FWD

AFT

SIDE SHELL OUTBOARD

PLATE A
6

WELD

7
PLATE A

LONGITUDINAL CENTERLINE BHD

FR-32

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-33

TANK TOP STIFFENERS-WATER BALLAST


TANK 9A (PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT04

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TANK TOP STIFFENERS-WATER BALLAST TANK 9A (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT04

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

STIFFENER

10.00

10.30

-3.0

-0.30

SATISFACTORY

25

STIFFENER

10.00

10.30

-3.0

-0.30

SATISFACTORY

25

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

STIFFENER

10.00

10.30

-3.0

-0.30

SATISFACTORY

25

STIFFENER

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

STIFFENER

10.00

10.80

-8.0

-0.80

SATISFACTORY

25

STIFFENER

10.00

10.40

-4.0

-0.40

SATISFACTORY

25

STIFFENER

10.00

10.10

-1.0

-0.10

SATISFACTORY

25

Page 1 of 1

FWD

AFT

TANK TOP

PLATE C

5
WELD

1
2

PLATE B

WELD

PLATE A

FR-32

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-33

TANK BOTTOM

SIDE SHELL OUTBOARD PLATING - WATER


BALLAST TANK 9A(PONTOON) STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT05

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

SIDE SHELL OUTBOARD PLATING - WATER BALLAST TANK 9A(PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT05

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5
PLATE B
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.70

12.90

-1.6

-0.20

SATISFACTORY

15

PLATING

12.70

12.90

-1.6

-0.20

SATISFACTORY

15

PLATING

12.70

13.00

-2.4

-0.30

SATISFACTORY

15

PLATING

12.70

12.90

-1.6

-0.20

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

13.20

-3.9

-0.50

SATISFACTORY

15

PLATING

12.70

13.10

-3.1

-0.40

SATISFACTORY

15

PLATING

12.70

13.10

-3.1

-0.40

SATISFACTORY

15

PLATING

12.70

12.80

-0.8

-0.10

SATISFACTORY

15

PLATING

12.70

13.00

-2.4

-0.30

SATISFACTORY

15

PLATING

12.70

12.90

-1.6

-0.20

SATISFACTORY

15

PLATING

12.70

12.90

-1.6

-0.20

SATISFACTORY

15

PLATING

12.70

12.90

-1.6

-0.20

SATISFACTORY

15

PLATING

12.70

12.50

1.6

0.20

SATISFACTORY

15

PLATING

12.70

12.20

3.9

0.50

SATISFACTORY

15

Page 1 of 1

FWD

AFT

TANK TOP

7
PLATE C

WELD

7
PLATE B

WELD

7
PLATE A

FR-32

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

FR-33

TANK BOTTOM

SIDE SHELL OUTBOARD STIFFENERS WATER BALLAST TANK 9A(PONTOON)


STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT06

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

SIDE SHELL OUTBOARD STIFFENERS - WATER BALLAST TANK 9A(PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT06

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F
PLATE C
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

STIFFENER

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

STIFFENER

12.00

12.00

0.0

0.00

SATISFACTORY

25

STIFFENER

12.00

11.80

1.7

0.20

SATISFACTORY

25

Page 1 of 1

R/S

ABS Wastage
Allowance (%)

STBD

PORT

TANK TOP

BEAM C

B2

8
BRACKET

BEAM B

BRACKET

B1
8

BEAM A
7

OUTBOARD SIDE SHELL

CENTER LINE W/T BULKHEAD

TANK BOTTOM

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

TRANSVERSE WEB PLATING FRAME


33-WATER BALLAST TANK 9A (PONTOON)
STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT07

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WEB PLATING FRAME 33-WATER BALLAST TANK 9A (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT07

AREA IDENTIFICATION
WEB FRAMING A
1
2
3
4
5
6
7
8
WEB FRAMING B
1
2
3
4
5
6
7
8
WEB FRAMING C
1
2
3
4
5
6
7
8

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

WEB FRAME

15.90

16.60

-4.4

-0.70

SATISFACTORY

25

WEB FRAME

15.90

16.40

-3.1

-0.50

SATISFACTORY

25

WEB FRAME

15.90

16.40

-3.1

-0.50

SATISFACTORY

25

WEB FRAME

15.90

16.40

-3.1

-0.50

SATISFACTORY

25

WEB FRAME

15.90

16.50

-3.8

-0.60

SATISFACTORY

25

WEB FRAME

15.90

16.40

-3.1

-0.50

SATISFACTORY

25

WEB FRAME

15.90

16.40

-3.1

-0.50

SATISFACTORY

25

WEB FRAME

15.90

16.50

-3.8

-0.60

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.00

0.0

0.00

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

WEB FRAME

14.00

14.30

-2.1

-0.30

SATISFACTORY

25

WEB FRAME

14.00

13.90

0.7

0.10

SATISFACTORY

25

WEB FRAME

14.00

14.30

-2.1

-0.30

SATISFACTORY

25

WEB FRAME

14.00

14.20

-1.4

-0.20

SATISFACTORY

25

Page 1 of 2

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WEB PLATING FRAME 33-WATER BALLAST TANK 9A (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT07

AREA IDENTIFICATION
WEB FRAME STIFFENERS
1
2
3
4
5
6
7
WEB FRAME BRACKETS
1
2

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

FRAME SRIFFENER

15.90

16.30

-2.5

-0.40

SATISFACTORY

25

FRAME SRIFFENER

15.90

16.30

-2.5

-0.40

SATISFACTORY

25

FRAME SRIFFENER

14.00

14.50

-3.6

-0.50

SATISFACTORY

25

FRAME SRIFFENER

14.00

14.00

0.0

0.00

SATISFACTORY

25

FRAME SRIFFENER

14.00

14.00

0.0

0.00

SATISFACTORY

25

FRAME SRIFFENER

14.00

14.00

0.0

0.00

SATISFACTORY

25

FRAME SRIFFENER

14.00

14.00

0.0

0.00

SATISFACTORY

25

FRAME BRACKET

12.70

12.60

0.8

0.10

SATISFACTORY

25

FRAME BRACKET

12.70

12.80

-0.8

-0.10

SATISFACTORY

25

Page 2 of 2

STBD

PORT

TANK TOP

4
5

4
3

4
1

4
2

4
5

PLATE A

PLATE B

4
3

4
1

4
2

TANK BOTTOM

PROJECT : ULTRASONIC THICKNESS GAUGING

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

TRANSVERSE WATERTIGHT BULKHEAD FR-31


PLATING-WATER BALLAST 9A (PONTOON)
STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT08

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WATERTIGHT BULKHEAD FR-31 PLATING-WATER BALLAST 9A (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT08

AREA IDENTIFICATION
PLATE A
1
2
3
4
5
PLATE B
1
2
3
4
5

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

R/S

ABS Wastage
Allowance (%)

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.00

0.0

0.00

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

PLATING

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

PLATING

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

PLATING

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

Page 1 of 1

STBD

PORT

TANK TOP

4
5

PLATE A

PLATE B

4
5

TANK BOTTOM

TRANSVERSE WATERTIGHT BULKHEAD FR-31


DESCRIPTION /
STIFFENERS-WATER BALLAST 9A (PONTOON)
LOCATION
STARBOARD

PROJECT : ULTRASONIC THICKNESS GAUGING


INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

K. SAMILIN/J.PERDIGON

APPROVED BY

JOSEPH KING

OES OILFIELD SERVICES GROUP

NOTE: ALL MEASUREMENTS IN MILLIMETERS

SATISFACTORY

XX

TEL: +5522 2773 2714


RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

TEST POINTS INDICATING


STIFFENERS (WEB / FLANGE)

SUBSTANTIAL
RENEWAL/REPLACE

VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

UT09

OES OILFIELD SERVICES GROUP


THICKNESS GAUGING SURVEY & INSPECTION
SAFE CONCORDIA
Date: March 2015

Report Number: 2015-391R

TRANSVERSE WATERTIGHT BULKHEAD FR-31 STIFFENERS-WATER BALLAST 9A (PONTOON) STARBOARD

Drawing Ref: OES-15-391-UT09

AREA IDENTIFICATION
PLATE A
6W
6F
7W
7F
PLATE B
6W
6F
7W
7F

DESCRIPTION

Original Thickness
(mm)

Gauged Thickness
(mm)

Gauged Diminution
(%)

Gauged Diminution
(mm)

STIFFENER

12.00

12.10

-0.8

-0.10

SATISFACTORY

25

STIFFENER

12.00

11.50

4.2

0.50

SATISFACTORY

25

STIFFENER

12.00

12.20

-1.7

-0.20

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

11.90

0.8

0.10

SATISFACTORY

25

STIFFENER

12.00

11.60

3.3

0.40

SATISFACTORY

25

STIFFENER

12.00

11.70

2.5

0.30

SATISFACTORY

25

STIFFENER

12.00

11.50

4.2

0.50

SATISFACTORY

25

Page 1 of 1

R/S

ABS Wastage
Allowance (%)

Pontoon Ballast Tank Drawings

)XHO Tank % - 3RUW

MPI Register - Fixed Equipment

OES Oilfield Services Group


MPI Examination Register - STR
Job Number : 2015-391
Client Name : Prosafe Production
Site : Safe Concordia

Date : 11th June, 2015


Office : BRASIL

Serial No.

Size

Item Test Description

Type

Manufacturer

Rating

FRC-1A

NOT
APPLICABLE

FAST RESCUE DAVIT DECK MAIN SUPPORT


BEAM PORT.

WELDED

UNKNOWN

1.2 TON

FRC-2A

NOT
APPLICABLE

FAST RESCUE DAVIT DECK MAIN SUPPORT


BEAM STARBOARD.

WELDED

UNKNOWN

1.2 TON

FRC-1

NOT
APPLICABLE

FAST RESCUE DAVIT DECK MAIN SUPPORT


TUBULAR PORT.

WELDED

UNKNOWN

1.2 TON

FRC-2

NOT
APPLICABLE

FAST RESCUE DAVIT DECK MAIN SUPPORT


TUBULAR STARBOARD.

WELDED

UNKNOWN

1.2 TON

LB-1-2A

NOT
APPLICABLE

LIFEBOAT 1 SUPPORT BEAM AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

SHIPYARD

LB-1-1A

NOT
APPLICABLE

LIFEBOAT 1 SUPPORT BEAM FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

SHIPYARD

LB-1-2

NOT
APPLICABLE

LIFEBOAT 1 SUPPORT TUBULAR AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

SHIPYARD

LB-1-1

NOT
APPLICABLE

LIFEBOAT 1 SUPPORT TUBULAR FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

SHIPYARD

LB-2-2A

NOT
APPLICABLE

LIFEBOAT 2 SUPPORT BEAM AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-2-1A

NOT
APPLICABLE

LIFEBOAT 2 SUPPORT BEAM FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-2-2

NOT
APPLICABLE

LIFEBOAT 2 SUPPORT TUBULAR AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-2-1

NOT
APPLICABLE

LIFEBOAT 2 SUPPORT TUBULAR FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-3-2A

NOT
APPLICABLE

LIFEBOAT 3 SUPPORT BEAM AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

Job Number : 2015-391

Page 1 of 9

Serial No.

Size

Item Test Description

Type

Manufacturer

Rating

LB-3-1A

NOT
APPLICABLE

LIFEBOAT 3 SUPPORT BEAM FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-3-2

NOT
APPLICABLE

LIFEBOAT 3 SUPPORT TUBULAR AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-3-1

NOT
APPLICABLE

LIFEBOAT 3 SUPPORT TUBULAR FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-4-2A

NOT
APPLICABLE

LIFEBOAT 4 SUPPORT BEAM AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-4-1A

NOT
APPLICABLE

LIFEBOAT 4 SUPPORT BEAM FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-4-2

NOT
APPLICABLE

LIFEBOAT 4 SUPPORT TUBULAR AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-4-1

NOT
APPLICABLE

LIFEBOAT 4 SUPPORT TUBULAR FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-5-2A

NOT
APPLICABLE

LIFEBOAT 5 SUPPORT BEAM AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

SHIPYARD

LB-5-1A

NOT
APPLICABLE

LIFEBOAT 5 SUPPORT BEAM FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

SHIPYARD

LB-5-2

NOT
APPLICABLE

LIFEBOAT 5 SUPPORT TUBULAR AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

SHIPYARD

LB-5-1

NOT
APPLICABLE

LIFEBOAT 5 SUPPORT TUBULAR FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

SHIPYARD

LB-6-2A

NOT
APPLICABLE

LIFEBOAT 6 SUPPORT BEAM AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-6-1A

NOT
APPLICABLE

LIFEBOAT 6 SUPPORT BEAM FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-6-2

NOT
APPLICABLE

LIFEBOAT 6 SUPPORT TUBULAR AFT


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

Job Number : 2015-391

Page 2 of 9

Serial No.

Size

Item Test Description

Type

Manufacturer

Rating

LB-6-1

NOT
APPLICABLE

LIFEBOAT 6 SUPPORT TUBULAR FORWARD


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-7-1A

NOT
APPLICABLE

LIFEBOAT 7 SUPPORT BEAM PORTSIDE


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-7-2A

NOT
APPLICABLE

LIFEBOAT 7 SUPPORT BEAM STARBOARD


SIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-7-1

NOT
APPLICABLE

LIFEBOAT 7 SUPPORT TUBULAR PORTSIDE


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-7-2

NOT
APPLICABLE

LIFEBOAT 7 SUPPORT TUBULAR


STARBOARD SIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-8-1A

NOT
APPLICABLE

LIFEBOAT 8 SUPPORT BEAM PORTSIDE


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-8-2A

NOT
APPLICABLE

LIFEBOAT 8 SUPPORT BEAM STARBOARD


SIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-8-1

NOT
APPLICABLE

LIFEBOAT 8 SUPPORT TUBULAR PORTSIDE


AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

LB-8-2

NOT
APPLICABLE

LIFEBOAT 8 SUPPORT TUBULAR


STARBOARD SIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS

WELD

UNKNOWN

NOT
APPLICABLE

1190

NOT
APPLICABLE

PORT CRANE AUXILIARY HOOK AND


HEADER BALL

FORGED

UNKNOWN

16 TON

150MM

PORT CRANE BASE WELD TO UPPER DECK


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

PORT CRANE BASE WELD TO UPPER DECK


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

PORT CRANE BASE WELD TO UPPER DECK


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

Job Number : 2015-391

Page 3 of 9

Serial No.

Size

Item Test Description

Type

Manufacturer

150MM

PORT CRANE BASE WELD TO UPPER DECK


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

B2

NOT
APPLICABLE

PORT CRANE BRACING SECTION 1 BOTTOM


AFT END WELD

WELD

FAVELLE FAVCO

120 TON

B2

NOT
APPLICABLE

PORT CRANE BRACING SECTION 1 BOTTOM


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

C2

NOT
APPLICABLE

PORT CRANE BRACING SECTION 1 TOP


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

C2

NOT
APPLICABLE

PORT CRANE BRACING SECTION 1 TOP


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

A 10

NOT
APPLICABLE

PORT CRANE BRACING SECTION 2


STARBOARD SIDE BOTTOM WELD

WELD

FAVELLE FAVCO

120 TON

A 10

NOT
APPLICABLE

PORT CRANE BRACING SECTION 2


STARBOARD SIDE TOP WELD

WELD

FAVELLE FAVCO

120 TON

B9290

NOT
APPLICABLE

PORT CRANE BRACING SECTION 2 TOP


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

B9290

NOT
APPLICABLE

PORT CRANE BRACING SECTION 2 TOP


PORTSIDE WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B9290

NOT
APPLICABLE

PORT CRANE BRACING SECTION 2 TOP


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

A6390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3


STARBOARD SIDE TOP WELD

WELD

FAVELLE FAVCO

120 TON

A4390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 BOTTOM


PORTSIDE WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A4390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 BOTTOM


PORTSIDE WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A4390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 BOTTOM


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A1390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 BOTTOM


WELD PORTSIDE

WELD

FAVELLE FAVCO

120 TON

A2390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 PORT


SIDE BOTTOM WELD

WELD

FAVELLE FAVCO

120 TON

A2390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 PORT


SIDE TOP WELD

WELD

FAVELLE FAVCO

120 TON

Job Number : 2015-391

Rating

Page 4 of 9

Serial No.

Size

Item Test Description

Type

Manufacturer

Rating

A4390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 PORT


SIDE WELD

WELD

FAVELLE FAVCO

120 TON

A4390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

A2390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 TOP


PORTSIDE WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A2390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 TOP


PORTSIDE WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A1390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 3 TOP


WELD PORTSIDE

WELD

FAVELLE FAVCO

120 TON

A2490

NOT
APPLICABLE

PORT CRANE BRACING SECTION 4


STARBOARD SIDE BOTTOM WELD

WELD

FAVELLE FAVCO

120 TON

A2490

NOT
APPLICABLE

PORT CRANE BRACING SECTION 4


STARBOARD SIDE TOP WELD

WELD

FAVELLE FAVCO

120 TON

B2490

NOT
APPLICABLE

PORT CRANE BRACING SECTION 4 TOP


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

B2490

NOT
APPLICABLE

PORT CRANE BRACING SECTION 4 TOP


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

B1590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 BOTTOM


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B2590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 BOTTOM


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A6390

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE BOTTOM WELD

WELD

FAVELLE FAVCO

120 TON

B28590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE REINFORCE WELD AFTER LOAD
TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B16590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE REINFORCE WELD AFTER LOAD
TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B21590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE REINFORCE WELD AFTER LOAD
TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B24590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE REINFORCE WELD AFTER LOAD
TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B24590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

Job Number : 2015-391

Page 5 of 9

Serial No.

Size

Item Test Description

Type

Manufacturer

Rating

B28590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

B21590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

B16590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

B28590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD REINFORCE WELD AFTER
LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B21590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD REINFORCE WELD AFTER
LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B16590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD REINFORCE WELD AFTER
LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B24590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD REINFORCE WELD AFTER
LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B1590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE BOTTOM WELD

WELD

FAVELLE FAVCO

120 TON

B2590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE BOTTOM WELD

WELD

FAVELLE FAVCO

120 TON

B4590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE BOTTOM WELD

WELD

FAVELLE FAVCO

120 TON

B1590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE TOP WELD

WELD

FAVELLE FAVCO

120 TON

B2590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE TOP WELD

WELD

FAVELLE FAVCO

120 TON

B4590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE TOP WELD

WELD

FAVELLE FAVCO

120 TON

B16590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

B24590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

B21590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

B26590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

Job Number : 2015-391

Page 6 of 9

Serial No.

Size

Item Test Description

Type

Manufacturer

Rating

A12590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

A12590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

A3590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


PORTSIDE WELD

WELD

FAVELLE FAVCO

120 TON

B22590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


PORTSIDE WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

AA3590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


PORTSIDE WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A12590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


PORTSIDE WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A3590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


STARBOARD SIDE WELD

WELD

FAVELLE FAVCO

120 TON

B4590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B4590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B2590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

B1590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A12590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

A3590

NOT
APPLICABLE

PORT CRANE BRACING SECTION 5 TOP


STARBOARD WELD AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT MARKED

700590102

NOT
APPLICABLE

PORT CRANE MAIN HOIST HOOK AFTER


LOAD TEST

FORGED

NOT MARKED

120.0 T

700590102

NOT
APPLICABLE

PORT CRANE MAIN HOIST HOOK AND BLOCK

FORGED

UNKNOWN

120 TON

150MM

PORT CRANE PEDESTAL WELD 1


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

PORT CRANE PEDESTAL WELD 1


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

Job Number : 2015-391

Page 7 of 9

Serial No.

Size

Item Test Description

Type

Manufacturer

150MM

PORT CRANE PEDESTAL WELD 1


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

PORT CRANE PEDESTAL WELD 1


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

PORT CRANE PEDESTAL WELD 5


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

PORT CRANE PEDESTAL WELD 5


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

PORT CRANE PEDESTAL WELD 5


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

PORT CRANE PEDESTAL WELD 5


INTERNAL
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

R13276

NOT
APPLICABLE

STARBOARD CRANE AUXILIARY HOOK AND


HEADER BALL

FORGED

UNKNOWN

5 TON

65898

NOT
APPLICABLE

STARBOARD CRANE MAIN HOIST HOOK AND


BLOCK

FORGED

UNKNOWN

25 TON

150MM

STARBOARD CRANE PEDESTAL BASE TO


UPPER DECK
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL BASE TO


UPPER DECK
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL BASE TO


UPPER DECK
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL BASE TO


UPPER DECK
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

Job Number : 2015-391

Rating

Page 8 of 9

Serial No.

Size

Item Test Description

Type

Manufacturer

Rating

150MM

STARBOARD CRANE PEDESTAL WELD 1


INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL WELD 1


INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL WELD 1


INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL WELD 1


INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL WELD 5


INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL WELD 5


INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL WELD 5


INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

150MM

STARBOARD CRANE PEDESTAL WELD 5


INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
PLEASE REFER TO LOCATION DRAWING

WELD

SHIPYARD

01

NOT
APPLICABLE

WELD TO CURRENT METER DAVIT


FOUNDATION AFT

WELDED

TECHOCEAN

NO APPLICABLE

04

NOT
APPLICABLE

WELD TO CURRENT METER DAVIT


FOUNDATION PORT

WELDED

TECHOCEAN

NO APPLICABLE

03

NOT
APPLICABLE

WELD TO CURRENT METER DAVIT


FOUNDATION PORT

WELDED

TECHOCEAN

NO APPLICABLE

02

NOT
APPLICABLE

WELD TO CURRENT METER DAVIT


FOUNDATION STBD

WELDED

TECHOCEAN

NO APPLICABLE

01

NOT
APPLICABLE

WELD TO STRUCTURE CRUTCH OF


GANGWAY

WELDED

TECHOCEAN

NO APPLICABLE

Item(s) / Certificate(s) reported in this Register : 133

Job Number : 2015-391

Page 9 of 9

MPI Reports / Certificates Fixed Equipment

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 1

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 10 April 2015

Date Put Into Service : Unknown

BRAZIL

1
150MM
Description: PORT CRANE BASE WELD TO UPPER DECK
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 2

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 10 April 2015

Date Put Into Service : Unknown

BRAZIL

2
150MM
Description: PORT CRANE BASE WELD TO UPPER DECK
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 3

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 10 April 2015

Date Put Into Service : Unknown

BRAZIL

3
150MM
Description: PORT CRANE BASE WELD TO UPPER DECK
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 4

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 10 April 2015

Date Put Into Service : Unknown

BRAZIL

4
150MM
Description: PORT CRANE BASE WELD TO UPPER DECK
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 5

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 10 April 2015

Date Put Into Service : Unknown

BRAZIL

1
150MM
Description: PORT CRANE PEDESTAL WELD 1
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 6

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 10 April 2015

Date Put Into Service : Unknown

BRAZIL

2
150MM
Description: PORT CRANE PEDESTAL WELD 1
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 7

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 10 April 2015

Date Put Into Service : Unknown

BRAZIL

3
150MM
Description: PORT CRANE PEDESTAL WELD 1
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 8

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 10 April 2015

Date Put Into Service : Unknown

BRAZIL

4
150MM
Description: PORT CRANE PEDESTAL WELD 1
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 9

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 12 April 2015

Date Put Into Service : Unknown

BRAZIL

1
150MM
Description: PORT CRANE PEDESTAL WELD 5
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 10

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 12 April 2015

Date Put Into Service : Unknown

BRAZIL

2
150MM
Description: PORT CRANE PEDESTAL WELD 5
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 11

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 12 April 2015

Date Put Into Service : Unknown

BRAZIL

3
150MM
Description: PORT CRANE PEDESTAL WELD 5
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 12

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 12 April 2015

Date Put Into Service : Unknown

BRAZIL

4
150MM
Description: PORT CRANE PEDESTAL WELD 5
INTERNAL
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 13

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 11 April 2015

Date Put Into Service : Unknown

BRAZIL

1
150MM
Description: STARBOARD CRANE PEDESTAL BASE TO UPPER
DECK
INTERNAL WELDMENT AREA
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 14

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 11 April 2015

Date Put Into Service : Unknown

BRAZIL

2
150MM
Description: STARBOARD CRANE PEDESTAL BASE TO UPPER
DECK
INTERNAL WELDMENT AREA
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 15

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 11 April 2015

Date Put Into Service : Unknown

BRAZIL

3
150MM
Description: STARBOARD CRANE PEDESTAL BASE TO UPPER
DECK
INTERNAL WELDMENT AREA
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 16

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 11 April 2015

Date Put Into Service : Unknown

BRAZIL

4
150MM
Description: STARBOARD CRANE PEDESTAL BASE TO UPPER
DECK
INTERNAL WELDMENT AREA
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 17

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 11 April 2015

Date Put Into Service : Unknown

BRAZIL

1
150MM
Description: STARBOARD CRANE PEDESTAL WELD 1
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 18

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 11 April 2015

Date Put Into Service : Unknown

BRAZIL

2
150MM
Description: STARBOARD CRANE PEDESTAL WELD 1
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 19

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 11 April 2015

Date Put Into Service : Unknown

BRAZIL

3
150MM
Description: STARBOARD CRANE PEDESTAL WELD 1
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 20

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 11 April 2015

Date Put Into Service : Unknown

BRAZIL

4
150MM
Description: STARBOARD CRANE PEDESTAL WELD 1
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 21

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 12 April 2015

Date Put Into Service : Unknown

BRAZIL

1
150MM
Description: STARBOARD CRANE PEDESTAL WELD 5
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 22

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 12 April 2015

Date Put Into Service : Unknown

BRAZIL

2
150MM
Description: STARBOARD CRANE PEDESTAL WELD 5
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 23

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 12 April 2015

Date Put Into Service : Unknown

BRAZIL

3
150MM
Description: STARBOARD CRANE PEDESTAL WELD 5
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 24

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 12 April 2015

Date Put Into Service : Unknown

BRAZIL

4
150MM
Description: STARBOARD CRANE PEDESTAL WELD 5
INTERNAL WELDMENT AREA
BEFORE LOAD TEST.
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON 150MM SECTION OF WELD AS PART OF 10% BACK UP FOR EDDY
CURRENT. AS PER INSTRUCTIONS OF ABS ALL MPI INSPECTIONS WERE CARRIED OUT INTERNALLY OF
CRANE PEDESTAL.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 25

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 14 April 2015

Date Put Into Service : Unknown

BRAZIL

LB-1-1
NOT APPLICABLE
Description: LIFEBOAT 1 SUPPORT TUBULAR FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 26

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 14 April 2015

Date Put Into Service : Unknown

BRAZIL

LB-1-2
NOT APPLICABLE
Description: LIFEBOAT 1 SUPPORT TUBULAR AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 27

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 14 April 2015

Date Put Into Service : Unknown

BRAZIL

LB-1-1A
NOT APPLICABLE
Description: LIFEBOAT 1 SUPPORT BEAM FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 28

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 14 April 2015

Date Put Into Service : Unknown

BRAZIL

LB-1-2A
NOT APPLICABLE
Description: LIFEBOAT 1 SUPPORT BEAM AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 29

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

LB-5-1
NOT APPLICABLE
Description: LIFEBOAT 5 SUPPORT TUBULAR FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR TO MAIN DECK
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 30

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

LB-5-2
NOT APPLICABLE
Description: LIFEBOAT 5 SUPPORT TUBULAR AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 31

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

LB-5-1A
NOT APPLICABLE
Description: LIFEBOAT 5 SUPPORT BEAM FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 32

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

LB-5-2A
NOT APPLICABLE
Description: LIFEBOAT 5 SUPPORT BEAM AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: SHIPYARD
Serial No.:
Size:

Type:

WELD

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 33

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B2
NOT APPLICABLE
PORT CRANE BRACING SECTION 1 BOTTOM AFT
END WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 34

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B2
NOT APPLICABLE
PORT CRANE BRACING SECTION 1 BOTTOM
PORTSIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 35

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

C2
NOT APPLICABLE
PORT CRANE BRACING SECTION 1 TOP PORTSIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 36

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

C2
NOT APPLICABLE
PORT CRANE BRACING SECTION 1 TOP
STARBOARD SIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 37

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A2490
NOT APPLICABLE
PORT CRANE BRACING SECTION 4 STARBOARD
SIDE BOTTOM WELD

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MMPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 38

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A2490
NOT APPLICABLE
PORT CRANE BRACING SECTION 4 STARBOARD
SIDE TOP WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 39

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B2490
NOT APPLICABLE
PORT CRANE BRACING SECTION 4 TOP
STARBOARD SIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 40

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B2490
NOT APPLICABLE
PORT CRANE BRACING SECTION 4 TOP PORTSIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 41

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A 10
NOT APPLICABLE
PORT CRANE BRACING SECTION 2 STARBOARD
SIDE BOTTOM WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 42

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A 10
NOT APPLICABLE
PORT CRANE BRACING SECTION 2 STARBOARD
SIDE TOP WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 43

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B9290
NOT APPLICABLE
PORT CRANE BRACING SECTION 2 TOP
STARBOARD SIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 44

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B9290
NOT APPLICABLE
PORT CRANE BRACING SECTION 2 TOP PORTSIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 45

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A2390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 PORT SIDE TOP
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 46

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A2390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 PORT SIDE
BOTTOM WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 47

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A4390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 PORT SIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 48

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A4390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 STARBOARD
SIDE WELD

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MMPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 49

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A3590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP PORTSIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 50

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A3590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP
STARBOARD SIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 51

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A12590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP PORTSIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 52

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A12590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP PORTSIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 53

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A6390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 STARBOARD
SIDE TOP WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 54

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A6390
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
BOTTOM WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 55

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A1390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 TOP WELD
PORTSIDE

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 56

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A1390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 BOTTOM WELD
PORTSIDE

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 57

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B1590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE BOTTOM WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 58

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B1590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE TOP WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 59

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B2590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE BOTTOM WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 60

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B2590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE TOP WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 61

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B4590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE BOTTOM WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 62

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B4590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE TOP WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 63

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B16590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
WELD

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MMPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 64

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B16590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 65

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B21590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
WELD

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MMPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 66

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B21590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 67

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B24590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 68

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B24590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 69

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B28590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 70

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

B26590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
SIDE WELD

Description:

Manufacturer: FAVELLE FAVCO


Type:

WELD

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON BRACING WELD 48HRS AFTER WELDING.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 71

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-2-2
NOT APPLICABLE
Description: LIFEBOAT 2 SUPPORT TUBULAR AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 72

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-2-1
NOT APPLICABLE
Description: LIFEBOAT 2 SUPPORT TUBULAR FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 73

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-2-1A
NOT APPLICABLE
Description: LIFEBOAT 2 SUPPORT BEAM FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 74

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-2-2A
NOT APPLICABLE
Description: LIFEBOAT 2 SUPPORT BEAM AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 75

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 15 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-3-1
NOT APPLICABLE
Description: LIFEBOAT 3 SUPPORT TUBULAR FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 76

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 15 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-3-2
NOT APPLICABLE
Description: LIFEBOAT 3 SUPPORT TUBULAR AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 77

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 15 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-3-1A
NOT APPLICABLE
Description: LIFEBOAT 3 SUPPORT BEAM FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 78

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 15 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-3-2A
NOT APPLICABLE
Description: LIFEBOAT 3 SUPPORT BEAM AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 79

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-4-1
NOT APPLICABLE
Description: LIFEBOAT 4 SUPPORT TUBULAR FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 80

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-4-2
NOT APPLICABLE
Description: LIFEBOAT 4 SUPPORT TUBULAR AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 81

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-4-1A
NOT APPLICABLE
Description: LIFEBOAT 4 SUPPORT BEAM FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 82

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-4-2A
NOT APPLICABLE
Description: LIFEBOAT 4 SUPPORT BEAM AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 83

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 16 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-6-1
NOT APPLICABLE
Description: LIFEBOAT 6 SUPPORT TUBULAR FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 84

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 16 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-6-2
NOT APPLICABLE
Description: LIFEBOAT 6 SUPPORT TUBULAR AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 85

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 16 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-6-1A
NOT APPLICABLE
Description: LIFEBOAT 6 SUPPORT BEAM FORWARD
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 86

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 16 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-6-2A
NOT APPLICABLE
Description: LIFEBOAT 6 SUPPORT BEAM AFT
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 87

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 16 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-7-1
NOT APPLICABLE
Description: LIFEBOAT 7 SUPPORT TUBULAR PORTSIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 88

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 16 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-7-2
NOT APPLICABLE
Description: LIFEBOAT 7 SUPPORT TUBULAR STARBOARD SIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 89

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 16 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-7-1A
NOT APPLICABLE
Description: LIFEBOAT 7 SUPPORT BEAM PORTSIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 90

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 16 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-7-2A
NOT APPLICABLE
Description: LIFEBOAT 7 SUPPORT BEAM STARBOARD SIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 91

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 18 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-8-1
NOT APPLICABLE
Description: LIFEBOAT 8 SUPPORT TUBULAR PORTSIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 92

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 18 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-8-2
NOT APPLICABLE
Description: LIFEBOAT 8 SUPPORT TUBULAR STARBOARD SIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT TUBULAR BASE TO MAIN
DECK WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 93

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 18 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-8-1A
NOT APPLICABLE
Description: LIFEBOAT 8 SUPPORT BEAM PORTSIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 94

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 18 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

LB-8-2A
NOT APPLICABLE
Description: LIFEBOAT 8 SUPPORT BEAM STARBOARD SIDE
AFTER LOAD TEST.
PLEASE REFER TO DRAWINGS
Manufacturer: UNKNOWN
Type:

WELD

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS FOR SUPPORT BEAM TO BULKHEAD
WELDS.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 95

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

1190
NOT APPLICABLE
PORT CRANE AUXILIARY HOOK AND HEADER
BALL

Manufacturer: UNKNOWN
Type:

FORGED

Rating:

16 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON ALL STRESS RELATED AREAS OF HOOK AND HEADER BALL
BEFORE LOAD TEST

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 96

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

700590102
NOT APPLICABLE
PORT CRANE MAIN HOIST HOOK AND BLOCK

Manufacturer: UNKNOWN
Type:

FORGED

Rating:

120 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON ALL STRESS RELATED AREAS OF HOOK AND MAIN BLOCK
BEFORE LOAD TEST.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 97

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

65898
NOT APPLICABLE
STARBOARD CRANE MAIN HOIST HOOK AND
BLOCK

Manufacturer: UNKNOWN
Type:

FORGED

Rating:

25 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON ALL STRESS RELATED AREAS OF HOOK AND MAIN BLOCK
BEFORE LOAD TEST.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 98

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

R13276
NOT APPLICABLE
STARBOARD CRANE AUXILIARY HOOK AND
HEADER BALL

Manufacturer: UNKNOWN
Type:

FORGED

Rating:

5 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON ALL STRESS RELATED AREAS OF HOOK AND HEADER BALL
BEFORE LOAD TEST.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 99

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

FRC-1
NOT APPLICABLE
FAST RESCUE DAVIT DECK MAIN SUPPORT
TUBULAR PORT.

Manufacturer: UNKNOWN
Type:

WELDED

Rating:

1.2 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS SUPPORT TUBULAR TO MAIN DECK AFTER
LOAD TEST.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 100

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

FRC-2
NOT APPLICABLE
FAST RESCUE DAVIT DECK MAIN SUPPORT
TUBULAR STARBOARD.

Manufacturer: UNKNOWN
Type:

WELDED

Rating:

1.2 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS SUPPORT TUBULAR TO MAIN DECK AFTER
LOAD TEST.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 101

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

FRC-1A
NOT APPLICABLE
FAST RESCUE DAVIT DECK MAIN SUPPORT BEAM
PORT.

Manufacturer: UNKNOWN
Type:

WELDED

Rating:

1.2 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS SUPPORT BEAM TO BULKHEAD AFTER
LOAD TEST.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 102

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 17 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

FRC-2A
NOT APPLICABLE
FAST RESCUE DAVIT DECK MAIN SUPPORT BEAM
STARBOARD.

Manufacturer: UNKNOWN
Type:

WELDED

Rating:

1.2 TON

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


MPI INSPECTION WAS CARRIED OUT ON WELDMENT AREAS SUPPORT BEAM TO BULKHEAD AFTER
LOAD TEST.

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 139

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B9290
NOT APPLICABLE
PORT CRANE BRACING SECTION 2 TOP PORTSIDE
WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 140

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A2390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 TOP PORTSIDE
WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 141

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A2390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 TOP PORTSIDE
WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 142

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A4390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 BOTTOM
PORTSIDE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 143

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A4390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 BOTTOM
PORTSIDE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 144

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

AA3590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP PORTSIDE
WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 145

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A4390
NOT APPLICABLE
PORT CRANE BRACING SECTION 3 BOTTOM
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 146

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A3590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 147

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A12590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 148

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

A12590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP PORTSIDE
WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 149

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B1590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 BOTTOM
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 150

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B1590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 151

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B2590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 152

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B2590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 BOTTOM
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 153

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B4590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 154

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B4590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP
STARBOARD WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 155

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B16590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
REINFORCE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 156

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B16590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
REINFORCE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 157

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B21590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
REINFORCE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 158

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B21590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
REINFORCE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 159

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B24590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
REINFORCE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 160

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B24590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
REINFORCE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 161

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B28590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 STARBOARD
REINFORCE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 162

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B28590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 PORTSIDE
REINFORCE WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 163

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

B22590
NOT APPLICABLE
PORT CRANE BRACING SECTION 5 TOP PORTSIDE
WELD AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:

WELDED

Rating:

NOT MARKED

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 164

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

01
NOT APPLICABLE
WELD TO STRUCTURE CRUTCH OF GANGWAY

Manufacturer: TECHOCEAN
Type:

WELDED

Rating:

NO APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 165

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 14 May 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

700590102
NOT APPLICABLE
PORT CRANE MAIN HOIST HOOK AFTER LOAD
TEST

Manufacturer: NOT MARKED


Type:

FORGED

Rating:

120.0 T

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 166

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

01
NOT APPLICABLE
WELD TO CURRENT METER DAVIT FOUNDATION
AFT

Manufacturer: TECHOCEAN
Type:

WELDED

Rating:

NO APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 167

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

02
NOT APPLICABLE
WELD TO CURRENT METER DAVIT FOUNDATION
STBD

Manufacturer: TECHOCEAN
Type:

WELDED

Rating:

NO APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 168

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

03
NOT APPLICABLE
WELD TO CURRENT METER DAVIT FOUNDATION
PORT

Manufacturer: TECHOCEAN
Type:

WELDED

Rating:

NO APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
FIXED STRUCTURES
Certificate No. 2015-391 / 169

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 19 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

04
NOT APPLICABLE
WELD TO CURRENT METER DAVIT FOUNDATION
PORT

Manufacturer: TECHOCEAN
Type:

WELDED

Rating:

NO APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

ELECTRO-MAGNET

AC

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Pole Spacing:
75 MM

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of
negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents
reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250, Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640 700 Fax: +44 (0)1224 640 900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

MPI Register Miscellaneous Equipment

OES Oilfield Services Group


MPI Examination Register - MISC
Job Number : 2015-391
Client Name : Prosafe Production
Site : Safe Concordia
Serial No.

Size

Item Test Description

06

NOT MARKED

BASE STRUCTURE WELD CRUTCH OF GANGWAY

05

NOT MARKED

04

Date : 11th June, 2015


Office : BRASIL
Manufacturer

Rating

WELDED

NOT MARKED

NOT
APPLICABLE

BASE STRUCTURE WELD CRUTCH OF GANGWAY

WELDED

NOT MARKED

NOT
APPLICABLE

NOT MARKED

BASE STRUCTURE WELD CRUTCH OF GANGWAY

WELDED

NOT MARKED

NOT
APPLICABLE

03

NOT MARKED

BASE STRUCTURE WELD CRUTCH OF GANGWAY

WELDED

NOT MARKED

NOT
APPLICABLE

02

NOT MARKED

BASE STRUCTURE WELD CRUTCH OF GANGWAY

WELDED

NOT MARKED

NOT
APPLICABLE

01

NOT MARKED

BASE STRUCTURE WELD CRUTCH OF GANGWAY

WELDED

NOT MARKED

NOT
APPLICABLE

R13276

NOT MARKED

STARBOARD CRANE AUXILIARY HOOK AND


HEADER BALL AFTER LOAD TEST

FORGED

NOT MARKED

NOT
APPLICABLE

65898

NOT MARKED

STARBOARD CRANE MAIN HOIST HOOK AFTER


LOAD TEST

FORGED

NOT MARKED

NOT
APPLICABLE

04

150MM

STBD CRANE BASE WELD TO UPPER DECK


INTERNAL
AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

03

150MM

STBD CRANE BASE WELD TO UPPER DECK


INTERNAL
AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

02

150MM

STBD CRANE BASE WELD TO UPPER DECK


INTERNAL
AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

01

150MM

STBD CRANE BASE WELD TO UPPER DECK


INTERNAL
AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

NOT MARKED

STBD CRANE BOOM TOP SECTION BRACINGS


PORT SIDE AFTER LOAD TEST.

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

NOT MARKED

STBD CRANE BOOM TOP SECTION BRACINGS


PORT SIDE AFTER LOAD TEST.

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A13491

Job Number : 2015-391

Type

Page 1 of 3

Serial No.

Size

Item Test Description

A13491

NOT MARKED

STBD CRANE BOOM TOP SECTION BRACINGS


STAR BOARDING SIDE AFTER LOAD TEST.

NOT MARKED

A1391

Manufacturer

Rating

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

STBD CRANE BOOM TOP SECTION BRACINGS


STARBOARD SIDE AFTER LOAD TEST.

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

NOT MARKED

STBD CRANE BOOM TOP SECTION BRACINGS


STARBOARD SIDE AFTER LOAD TEST.

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A2341

NOT MARKED

STBD CRANE EXTENSION 2 BOTTOM WELD


BRACINGS STARBOARD SIDE AFTER CHANGE
BRACING AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A2341

NOT MARKED

STBD CRANE EXTENSION 2 BOTTOM WELD


BRACINGS STARBOARD SIDE AFTER CHANGE
BRACING.

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A2341

NOT MARKED

STBD CRANE EXTENSION 2 BOTTOM WELD


BRACINGS STARBOARD SIDE AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A2391

NOT MARKED

STBD CRANE EXTENSION 2 BOTTOM WELDING


STARBOARD BRACINGS AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A2341

NOT MARKED

STBD CRANE EXTENSION 2 TOP WELD BRACINGS


STARBOARD SIDE AFTER CHANGE BRACING
AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A2341

NOT MARKED

STBD CRANE EXTENSION 2 TOP WELD BRACINGS


STARBOARD SIDE AFTER CHANGE BRACING.

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A2341

NOT MARKED

STBD CRANE EXTENSION 2 TOP WELD BRACINGS


STARBOARD SIDE AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A1807

NOT MARKED

STBD CRANE EXTENSION 2 TOP WELD PORT


BRACINGS STARBOARD SIDE AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A2391

NOT MARKED

STBD CRANE EXTENSION 2 TOP WELD


STARBOARD BRACINGS AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

A1807

NOT MARKED

STBD CRANE EXTENSION 2 TOP WELD


STARBOARD SIDE BRACINGS AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

01

150MM

STBD CRANE PEDESTAL WELD 1 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

04

150MM

STBD CRANE PEDESTAL WELD 1 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

03

150MM

STBD CRANE PEDESTAL WELD 1 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

02

150MM

STBD CRANE PEDESTAL WELD 1 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

Job Number : 2015-391

Type

Page 2 of 3

Serial No.

Size

Item Test Description

01

150MM

STBD CRANE PEDESTAL WELD 5 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

02

150MM

03

Type

Manufacturer

Rating

WELDED

NOT MARKED

NOT
APPLICABLE

STBD CRANE PEDESTAL WELD 5 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

150MM

STBD CRANE PEDESTAL WELD 5 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

04

150MM

STBD CRANE PEDESTAL WELD 5 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING

WELDED

NOT MARKED

NOT
APPLICABLE

A13491

NOT MARKED

STBD CRANE TOP SECTION BOTTOM BRACINGS


PORT SIDE AFTER LOAD TEST

WELDED

FAVELLE FAVCO

NOT
APPLICABLE

Item(s) / Certificate(s) reported in this Register : 36

Job Number : 2015-391

Page 3 of 3

MPI Reports / Certificates Miscellaneous Equipment

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 103

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

01
150MM

STBD CRANE BASE WELD TO UPPER DECK


INTERNAL
AFTER LOAD TEST
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 104

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

02
150MM

STBD CRANE BASE WELD TO UPPER DECK


INTERNAL
AFTER LOAD TEST
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 105

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

03
150MM

STBD CRANE BASE WELD TO UPPER DECK


INTERNAL
AFTER LOAD TEST
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 106

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

04
150MM

STBD CRANE BASE WELD TO UPPER DECK


INTERNAL
AFTER LOAD TEST
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 107

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

01
150MM

STBD CRANE PEDESTAL WELD 1 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 108

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

02
150MM

STBD CRANE PEDESTAL WELD 1 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 109

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

03
150MM

STBD CRANE PEDESTAL WELD 1 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 110

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

04
150MM

STBD CRANE PEDESTAL WELD 1 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 111

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

01
150MM

STBD CRANE PEDESTAL WELD 5 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 112

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

02
150MM

STBD CRANE PEDESTAL WELD 5 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 113

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

03
150MM

STBD CRANE PEDESTAL WELD 5 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 114

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

04
150MM

STBD CRANE PEDESTAL WELD 5 INTERNAL


AFTER LOAD TEST
PLEASE REFER TO LOCATION DRAWING
Manufacturer: NOT MARKED
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL FOR INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 115

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A13491
NOT MARKED

Description:

STBD CRANE TOP SECTION BOTTOM BRACINGS


PORT SIDE AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 116

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A13491
NOT MARKED

Description:

STBD CRANE BOOM TOP SECTION BRACINGS


STAR BOARDING SIDE AFTER LOAD TEST.

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 117

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

NOT MARKED
STBD CRANE BOOM TOP SECTION BRACINGS
PORT SIDE AFTER LOAD TEST.

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 118

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

Serial No.:
Size:
Description:

BRAZIL

NOT MARKED
STBD CRANE BOOM TOP SECTION BRACINGS
STARBOARD SIDE AFTER LOAD TEST.

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 119

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A13491
NOT MARKED

Description:

STBD CRANE BOOM TOP SECTION BRACINGS


PORT SIDE AFTER LOAD TEST.

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 120

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A1391
NOT MARKED

Description:

STBD CRANE BOOM TOP SECTION BRACINGS


STARBOARD SIDE AFTER LOAD TEST.

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 121

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A2341
NOT MARKED

Description:

STBD CRANE EXTENSION 2 TOP WELD BRACINGS


STARBOARD SIDE AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
DISCONTINUITIES DETECTED AT THE TIME OF INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 122

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A2341
NOT MARKED

Description:

STBD CRANE EXTENSION 2 BOTTOM WELD


BRACINGS STARBOARD SIDE AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 123

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A1807
NOT MARKED

Description:

STBD CRANE EXTENSION 2 TOP WELD PORT


BRACINGS STARBOARD SIDE AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 124

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A1807
NOT MARKED

Description:

STBD CRANE EXTENSION 2 TOP WELD


STARBOARD SIDE BRACINGS AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 125

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 29 April 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A2391
NOT MARKED

Description:

STBD CRANE EXTENSION 2 TOP WELD


STARBOARD BRACINGS AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 126

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A2391
NOT MARKED

Description:

STBD CRANE EXTENSION 2 BOTTOM WELDING


STARBOARD BRACINGS AFTER LOAD TEST

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 127

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 01 May 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A2341
NOT MARKED

STBD CRANE EXTENSION 2 BOTTOM WELD


BRACINGS STARBOARD SIDE AFTER CHANGE
BRACING.
Manufacturer: FAVELLE FAVCO
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 128

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 04 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

A2341
NOT MARKED

Description:

STBD CRANE EXTENSION 2 TOP WELD BRACINGS


STARBOARD SIDE AFTER CHANGE BRACING.

Manufacturer: FAVELLE FAVCO


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 129

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 04 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

01
NOT MARKED

Description:

BASE STRUCTURE WELD CRUTCH OF GANGWAY

Manufacturer: NOT MARKED


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 130

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 04 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

02
NOT MARKED

Description:

BASE STRUCTURE WELD CRUTCH OF GANGWAY

Manufacturer: NOT MARKED


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 131

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 04 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

03
NOT MARKED

Description:

BASE STRUCTURE WELD CRUTCH OF GANGWAY

Manufacturer: NOT MARKED


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 132

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 04 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

04
NOT MARKED

Description:

BASE STRUCTURE WELD CRUTCH OF GANGWAY

Manufacturer: NOT MARKED


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 133

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 04 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

05
NOT MARKED

Description:

BASE STRUCTURE WELD CRUTCH OF GANGWAY

Manufacturer: NOT MARKED


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 134

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 04 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

06
NOT MARKED

Description:

BASE STRUCTURE WELD CRUTCH OF GANGWAY

Manufacturer: NOT MARKED


Type:
WELDED
Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 135

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 06 May 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A2341
NOT MARKED

STBD CRANE EXTENSION 2 BOTTOM WELD


BRACINGS STARBOARD SIDE AFTER CHANGE
BRACING AFTER LOAD TEST
Manufacturer: FAVELLE FAVCO
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 136

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 06 May 2015

Date Put Into Service : Unknown

Serial No.:
Size:

BRAZIL

A2341
NOT MARKED

STBD CRANE EXTENSION 2 TOP WELD BRACINGS


STARBOARD SIDE AFTER CHANGE BRACING
AFTER LOAD TEST
Manufacturer: FAVELLE FAVCO
Type:
WELDED
Description:

Rating:

NOT APPLICABLE

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CONNECTIONS WELDS AND HEAT AFFECTED ZONES INSPECTED

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 137

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 06 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

65898
NOT MARKED

Description:

STARBOARD CRANE MAIN HOIST HOOK AFTER


LOAD TEST

Manufacturer: NOT MARKED


Type:
FORGED
NOT APPLICABLE

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL INSPECTION, UNIT NOT DISASSEMBLED FOR
INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


MAGNETIC PARTICLE INSPECTION REPORT
MISCELLANEOUS EQUIPMENT
Certificate No. 2015-391 / 138

Office : BRASIL

Invoice Address/Customer:

Date : 26 May 2015

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection : 06 May 2015

Date Put Into Service : Unknown

BRAZIL

Serial No.:
Size:

R13276
NOT MARKED

Description:

STARBOARD CRANE AUXILIARY HOOK AND


HEADER BALL AFTER LOAD TEST

Manufacturer: NOT MARKED


Type:
FORGED
NOT APPLICABLE

Rating:

Acceptance Standard:

Test Procedure Number:

Viewing Conditions:

AWS D1.1 Current Edition

ID I 25 / BS EN ISO 9934-1 2001

Visible light (Recommended) - 1000 Lux

Preparation:

Material:

Stage of Examination:

PAINT REMOVED & SURFACE CLEANED

CARBON STEEL

IN SERVICE

Magnetic Particle
Equipment Type:

Current

Pole Spacing:

ELECTRO-MAGNET

AC/DC

75 MM

Contrast Media:

Indicator:

MAGNAFLUX WCP2

MAGNAFLUX 7HF

Calibration Equipment Type & Serial Number:

Flux Reading:

BURMAH-CASTROL STRIP

3 LINES

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Test Restrictions / Comments:


CATEGORY III-PARTIAL EXTERNAL INSPECTION, UNIT NOT DISASSEMBLED FOR
INSPECTION

Method of Recording or Marking of Indications:


NOT APPLICABLE

Demagnetisation / Residual Field Strength After Test:


NOT APPLICABLE / ACCEPTABLE

Name & Qualification :

Signed/Stamp

LIMA, RODOLFO
MT LEVEL II, PT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express
or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be liable for any injury or damage to any person or property occurring by reason of negligent
operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed
by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to list all hazards or faulty conditions not to
indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-01, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

Eddy Current Inspection


Certificates & Register

OES Oilfield Services Group


Eddy Current Examination Register
Job Number : 2015-391
Client Name : Prosafe Production
Site : Safe Concordia

Date : 11th June, 2015


Office : BRASIL
Inspector: MCGREGOR, THOMAS

Cert ID

Serial No.

SWL

Item Description

Results

1001

01

NOT
APPLICABLE

STARBOARD CENTER COLUMN WELD TO


PONTOON DECK

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1002

02

NOT
APPLICABLE

STARBOARD CENTER COLUMN WELD TO


PONTOON DECK

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1003

03

NOT
APPLICABLE

STARBOARD CENTER COLUMN WELD TO


PONTOON DECK

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1004

04

NOT
APPLICABLE

STARBOARD CENTER COLUMN WELD TO


PONTOON DECK

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1005

05

NOT
APPLICABLE

STARBOARD CENTER COLUMN WELD TO


PONTOON DECK

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1006

06

NOT
APPLICABLE

STARBOARD CENTER COLUMN WELD TO


PONTOON DECK

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1007

07

NOT
APPLICABLE

STARBOARD CENTER COLUMN WELD TO


PONTOON DECK

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1008

PLATE A

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1009

PLATE A1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A1 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1010

PLATE A2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A2 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1011

PLATE A3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A3 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1012

PLATE B

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1013

PLATE B1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B1 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1014

PLATE B2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B2 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1015

PLATE B3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B3 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1016

PLATE C

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1017

PLATE C1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C1 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1018

PLATE C2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C2 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1019

PLATE C3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C3 STARBOARD


SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1020

WELD 1

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 1


STARBOARD SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1021

WELD 2

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 2


STARBOARD SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 1 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1022

WELD 3

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 3


INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1023

WELD 4

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


4 INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1024

WELD 5

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 5


INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1025

WELD 6

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 6


INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1026

WELD 7

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 7


INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1027

WELD 8

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 8


INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1028

WELD 9

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 9


INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1029

WELD 10

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


10 INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1030

WELD 11

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


11 INTERNAL OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1031

WELD 12

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


12 INTERNAL OF PORTSIDE AFT HORIZONTAL
BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1032

WELD 13

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


13 INTERNAL OF PORTSIDE AFT HORIZONTAL
BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1033

PLATE A

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1034

PLATE A1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A1 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1035

PLATE A2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A2 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1036

PLATE A3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A3 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1037

PLATE B

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1038

PLATE B1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B1 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1039

PLATE B2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B2 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1040

PLATE B3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B3 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1041

PLATE C

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1042

PLATE C1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C1 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1043

PLATE C2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C2 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1044

PLATE C3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C3 PORT SIDE OF


AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 2 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1045

PLATE A

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1046

PLATE A1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A1 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1047

PLATE A2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A2 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1048

PLATE A3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A3 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1049

PLATE B

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1050

PLATE B1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B1 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1051

PLATE B2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B2 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1052

PLATE B3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B3 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1053

PLATE C

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1054

PLATE C1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C1 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1055

PLATE C2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C2 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1056

PLATE C3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C3 PORT SIDE OF


CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1057

PLATE A

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1058

PLATE A1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A1 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1059

PLATE A2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A2 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1060

PLATE A3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A3 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1061

PLATE B

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1062

PLATE B1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B1 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1063

PLATE B2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B2 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1064

PLATE B3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B3 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1065

PLATE C

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1066

PLATE C1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C1 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1067

PLATE C2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C2 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 3 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1068

PLATE C3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C3 STARBOARD


SIDE OF CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1069

PLATE A

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1070

PLATE A1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A1 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1071

PLATE A2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A2 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1072

PLATE A3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A3 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1073

PLATE B

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1074

PLATE B1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B1 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1075

PLATE B2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B2 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1076

PLATE B3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B3 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1077

PLATE C

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1078

PLATE C1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C1 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1079

PLATE C2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C2 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1080

PLATE C3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C3 PORT SIDE OF


FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1081

WELD 1

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 1


STARBOARD SIDE OF FORWARD HORIZONTAL
BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1082

WELD 2

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 2


STARBOARD SIDE OF FORWARD HORIZONTAL
BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1083

WELD 3

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 3


INTERNAL OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1084

WELD 4

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 4


INTERNAL OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1085

WELD 5

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 5


INTERNAL OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1086

WELD 6

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 6


INTERNAL OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1087

WELD 7

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 7


INTERNAL OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1088

WELD 8

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 8


INTERNAL OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1089

WELD 9

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD 9


INTERNAL OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 4 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1090

WELD 10

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


10 INTERNAL OF FORWARD HORIZONTAL
BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1091

WELD 11

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


11 INTERNAL OF FORWARD HORIZONTAL
BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1092

WELD 12

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


12 PORT SIDE OF FORWARD HORIZONTAL
BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1093

WELD 13

NOT
APPLICABLE

CIRCUMFERENCE WELDMENT AREAS OF WELD


13 PORT SIDE OF FORWARD HORIZONTAL
BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1094

PLATE A

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1095

PLATE A1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A1 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1096

PLATE A2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A2 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1097

PLATE A3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE A3 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1098

PLATE B

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1099

PLATE B1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B1 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1100

PLATE B2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B2 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1101

PLATE B3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE B3 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1102

PLATE C

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1103

PLATE C1

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C1 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1104

PLATE C2

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C2 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1105

PLATE C3

NOT
APPLICABLE

WELDMENT AREAS OF PLATE C3 STARBOARD


SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1106

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 4A LEVEL 67.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1107

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 4A LEVEL 67.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1108

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 4A LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1109

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 4B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1110

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 4B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1111

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 4B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 5 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1112

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 3A LEVEL 67.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1113

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 3A LEVEL 67.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1114

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 3A LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1115

10

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 3B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1116

11

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 3B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1117

12

NOT
APPLICABLE

PORT CENTER COLUMN VOID TANK 3B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1118

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 6A LEVEL 66.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1119

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 6A LEVEL 66.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1120

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 6A LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1121

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 6B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1122

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 6B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1123

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 6B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1124

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 5A LEVEL 66.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1125

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 5A LEVEL 66.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1126

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 5A LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1127

10

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 5B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1128

11

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 5B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1129

12

NOT
APPLICABLE

PORT AFT COLUMN VOID TANK 5B LEVEL 52.


WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1130

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 5A LEVEL


66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1131

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 5A LEVEL


52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1132

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 5B LEVEL


52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1133

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 5B LEVEL


52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 6 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1134

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 5B LEVEL


52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1135

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 6A LEVEL


66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1136

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 6A LEVEL


66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1137

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 6A LEVEL


52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1138

10

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 6B LEVEL


52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1139

11

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 6B LEVEL


52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1140

12

NOT
APPLICABLE

STARBOARD AFT COLUMN VOID TANK 6B LEVEL


52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1141

NOT
APPLICABLE

STARBOARD CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1142

NOT
APPLICABLE

STARBOARD CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1143

NOT
APPLICABLE

STARBOARD CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1144

NOT
APPLICABLE

STARBOARD CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1145

NOT
APPLICABLE

STARBOARD CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1146

NOT
APPLICABLE

STARBOARD CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1147

NOT
APPLICABLE

STARBOARD CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1148

NOT
APPLICABLE

STARBOARD CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1149

NOT
APPLICABLE

STARBOARD CRANE WELD 1 ON PEDESTAL


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 7 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1150

10

NOT
APPLICABLE

STARBOARD CRANE WELD 1 ON PEDESTAL


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1151

11

NOT
APPLICABLE

STARBOARD CRANE WELD 1 ON PEDESTAL


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1152

12

NOT
APPLICABLE

STARBOARD CRANE WELD 1 ON PEDESTAL


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1153

13

NOT
APPLICABLE

STARBOARD CRANE WELD 5 ON PEDESTAL


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1154

14

NOT
APPLICABLE

STARBOARD CRANE WELD 5 ON PEDESTAL


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1155

15

NOT
APPLICABLE

STARBOARD CRANE WELD 5 ON PEDESTAL


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1156

16

NOT
APPLICABLE

STARBOARD CRANE WELD 5 ON PEDESTAL


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1157

NOT
APPLICABLE

PORT CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1158

NOT
APPLICABLE

PORT CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1159

NOT
APPLICABLE

PORT CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1160

NOT
APPLICABLE

PORT CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1161

NOT
APPLICABLE

PORT CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1162

NOT
APPLICABLE

PORT CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1163

NOT
APPLICABLE

PORT CRANE BASE TO UPPER DECK


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1164

NOT
APPLICABLE

PORT CRANE WELD 1


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 8 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1165

NOT
APPLICABLE

PORT CRANE WELD 1


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1166

10

NOT
APPLICABLE

PORT CRANE WELD 1


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1167

11

NOT
APPLICABLE

PORT CRANE WELD 4


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1168

12

NOT
APPLICABLE

PORT CRANE WELD 4


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1169

13

NOT
APPLICABLE

PORT CRANE WELD 4


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1170

14

NOT
APPLICABLE

PORT CRANE WELD 4


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1171

15

NOT
APPLICABLE

PORT CRANE WELD 5


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1172

16

NOT
APPLICABLE

PORT CRANE WELD 5


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1173

17

NOT
APPLICABLE

PORT CRANE WELD 5


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1174

18

NOT
APPLICABLE

PORT CRANE WELD 5


EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1175

NOT APPLICABLE

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED OUT


ON WELDMENT AREAS OF NEW SUPPORT BEAM
FOR FAST RESCUE DAVIT DECK.
AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1176

NOT APPLICABLE

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED OUT


ON WELDMENT AREAS OF NEW SUPPORT
TUBULAR FOR FAST RESCUE DAVIT DECK.
AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1177

WELD 2-01

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1178

WELD 2-02

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1179

WELD 2-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1180

WELD 2-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1181

WELD 3-01

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1182

WELD 3-02

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 9 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1183

WELD 3-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1184

WELD 3-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1185

WELD 4-01

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1186

WELD 4-02

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1187

WELD 4-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1188

WELD 4-04

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING STBD CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1224

WELD 1-01

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1225

WELD 1-02

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1226

WELD 1-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1227

WELD 1-04

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1228

WELD 1-05

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1229

WELD 1-06

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1230

WELD 1-07

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1231

WELD 2-01

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1232

WELD 2-02

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1233

WELD 2-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1234

WELD 2-05

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1235

WELD 2-06

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1236

WELD 2-07

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1237

WELD 2-07

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1238

WELD 3-01

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1239

WELD 3-02

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1240

WELD 3-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1241

WELD 3-04

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1242

WELD 4-01

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Page 10 of 11

Cert ID

Serial No.

SWL

Item Description

Results

1243

WELD 4-02

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1244

WELD 4-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1245

WELD 4-04

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1246

WELD 5-01

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1247

WELD 5-02

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1248

WELD 5-03

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1249

WELD 5-04

NOT
APPLICABLE

EDDY CURRENT INSPECTION WAS CARRIED ON


THE WELDING PORT CRANE AFTER LOAD TEST.

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1250

B2

NOT
APPLICABLE

PORT CRANE SECTION 1 BOTTOM STBD WELD


AFTER LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1251

B2

NOT
APPLICABLE

PORT CRANE SECTION 1 BOTTOM PORT WELD


AFTER LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1252

C2

NOT
APPLICABLE

PORT CRANE SECTION 1 TOP PORT WELD AFTER


LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1253

C2

NOT
APPLICABLE

PORT CRANE SECTION 1 TOP STBD WELD AFTER


LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1254

B2490

NOT
APPLICABLE

PORT CRANE SECTION 4 TOP STBD WELD AFTER


LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1255

B2490

NOT
APPLICABLE

PORT CRANE SECTION 4 TOP PORT WELD AFTER


LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1256

A2490

NOT
APPLICABLE

PORT CRANE SECTION 4 BOTTOM STBD WELD


AFTER LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1257

A2490

NOT
APPLICABLE

PORT CRANE SECTION 4 TOP STBD WELD AFTER


LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1258

A10

NOT
APPLICABLE

PORT CRANE SECTION 2 BOTTOM STBD WELD


AFTER LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1259

A10

NOT
APPLICABLE

PORT CRANE SECTION 2 TOP STBD WELD


AFTER LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

1260

B9290

NOT
APPLICABLE

PORT CRANE SECTION 2 TOP STBD WELD AFTER


LOAD TEST

NO DEFECTS OR SURFACE BREAKING


DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Item(s) / Certificate(s) reported in this Register : 225

Page 11 of 11

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1001

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

01

Not Applicable

Job Description/Particulars:
STARBOARD CENTER COLUMN WELD TO PONTOON DECK

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
57/57

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


2MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1002

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

02

Not Applicable

Job Description/Particulars:
STARBOARD CENTER COLUMN WELD TO PONTOON DECK

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
57/57

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


2MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1003

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

03

Not Applicable

Job Description/Particulars:
STARBOARD CENTER COLUMN WELD TO PONTOON DECK

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
57/57

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


2MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1004

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

04

Not Applicable

Job Description/Particulars:
STARBOARD CENTER COLUMN WELD TO PONTOON DECK

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
57/57

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


2MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1005

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

05

Not Applicable

Job Description/Particulars:
STARBOARD CENTER COLUMN WELD TO PONTOON DECK

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
57/57

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


2MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1006

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

06

Not Applicable

Job Description/Particulars:
STARBOARD CENTER COLUMN WELD TO PONTOON DECK

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
57/57

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


2MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1007

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

07

Not Applicable

Job Description/Particulars:
STARBOARD CENTER COLUMN WELD TO PONTOON DECK

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
57/57

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


2MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1008

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1009

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A1 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1010

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A2 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1011

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A3 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1012

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1013

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B1 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1014

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B2 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1015

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B3 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1016

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1017

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C1 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1018

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C2 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1019

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C3 STARBOARD SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1020

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 1 STARBOARD
SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1021

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 2 STARBOARD
SIDE OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1022

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 3 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1023

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 4 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1024

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 5

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 5 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1025

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 6

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 6 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1026

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 7

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 7 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1027

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 8

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 8 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1028

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 9

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 9 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1029

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 10

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 10 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1030

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 11

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 11 INTERNAL
OF AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1031

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 12

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 12 INTERNAL
OF PORTSIDE AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1032

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 13

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 13 INTERNAL
OF PORTSIDE AFT HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1033

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1034

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A1 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1035

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A2 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1036

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A3 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1037

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1038

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B1 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1039

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B2 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1040

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B3 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1041

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1042

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C1 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1043

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C2 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1044

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C3 PORT SIDE OF AFT
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1045

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1046

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A1 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1047

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A2 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1048

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A3 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1049

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1050

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B1 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1051

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B2 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1052

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B3 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1053

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1054

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C1 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1055

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C2 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1056

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C3 PORT SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1057

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A STARBOARD SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1058

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A1 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1059

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A2 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1060

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A3 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1061

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B STARBOARD SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1062

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B1 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1063

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B2 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1064

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B3 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1065

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C STARBOARD SIDE OF CENTER
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1066

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C1 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1067

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C2 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1068

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

30th March, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C3 STARBOARD SIDE OF
CENTER HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1069

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1070

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A1 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1071

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A2 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1072

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A3 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1073

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1074

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B1 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1075

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B2 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1076

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B3 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1077

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1078

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C1 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1079

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C2 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1080

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C3 PORT SIDE OF FORWARD
HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1081

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 1 STARBOARD
SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1082

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 2 STARBOARD
SIDE OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1083

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 3 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1084

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 4 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1085

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 5

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 5 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1086

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 6

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 6 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1087

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 7

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 7 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1088

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 8

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 8 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1089

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 9

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 9 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1090

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 10

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 10 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1091

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 11

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 11 INTERNAL
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1092

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 12

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 12 PORT SIDE
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1093

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 13

Not Applicable

Job Description/Particulars:
CIRCUMFERENCE WELDMENT AREAS OF WELD 13 PORT SIDE
OF FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1094

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1095

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A1 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1096

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A2 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1097

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate A3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE A3 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1098

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1099

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B1 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1100

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B2 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1101

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate B3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE B3 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1102

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1103

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C1

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C1 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1104

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C2

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C2 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1105

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

2nd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Plate C3

Not Applicable

Job Description/Particulars:
WELDMENT AREAS OF PLATE C3 STARBOARD SIDE OF
FORWARD HORIZONTAL BRACING.
PLEASE REFER TO DRAWING FOR LOCATION.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1106

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 4A LEVEL 67.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1107

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 4A LEVEL 67.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1108

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 4A LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1109

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 4B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1110

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 4B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1111

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 4B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1112

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 3A LEVEL 67.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1113

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 3A LEVEL 67.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1114

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 3A LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1115

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

10

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 3B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1116

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

11

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 3B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1117

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

3rd April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

12

Not Applicable

Job Description/Particulars:
PORT CENTER COLUMN VOID TANK 3B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1118

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 6A LEVEL 66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1119

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 6A LEVEL 66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1120

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 6A LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1121

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 6B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1122

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 6B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1123

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 6B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1124

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 5A LEVEL 66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1125

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 5A LEVEL 66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1126

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 5A LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1127

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

10

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 5B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1128

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

11

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 5B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1129

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

1st April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

12

Not Applicable

Job Description/Particulars:
PORT AFT COLUMN VOID TANK 5B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1130

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

8th February, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 5A LEVEL 66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1131

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 5A LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1132

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 5B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1133

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 5B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1134

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 5B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1135

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 6A LEVEL 66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1136

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 6A LEVEL 66.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1137

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 6A LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1138

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

10

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 6B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1139

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

11

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 6B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1140

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

4th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

12

Not Applicable

Job Description/Particulars:
STARBOARD AFT COLUMN VOID TANK 6B LEVEL 52.
WELDMENT AREA OF MAIN DECK TO COLUMN.
WELD SIZE INSPECTED 500MM X 500MM.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1141

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE BASE TO UPPER DECK EXTERNAL
WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1142

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE BASE TO UPPER DECK EXTERNAL
WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1143

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE BASE TO UPPER DECK EXTERNAL
WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1144

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE BASE TO UPPER DECK EXTERNAL
WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1145

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE BASE TO UPPER DECK EXTERNAL
WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1146

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE BASE TO UPPER DECK EXTERNAL
WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1147

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE BASE TO UPPER DECK EXTERNAL
WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1148

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE BASE TO UPPER DECK EXTERNAL
WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1149

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
STARBOARD CRANE WELD 1 ON PEDESTAL
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1150

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

10

Not Applicable

Job Description/Particulars:
STARBOARD CRANE WELD 1 ON PEDESTAL
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1151

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

11

Not Applicable

Job Description/Particulars:
STARBOARD CRANE WELD 1 ON PEDESTAL
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1152

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

9th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

12

Not Applicable

Job Description/Particulars:
STARBOARD CRANE WELD 1 ON PEDESTAL
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1153

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

13

Not Applicable

Job Description/Particulars:
STARBOARD CRANE WELD 5 ON PEDESTAL
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1154

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

14

Not Applicable

Job Description/Particulars:
STARBOARD CRANE WELD 5 ON PEDESTAL
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1155

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

15

Not Applicable

Job Description/Particulars:
STARBOARD CRANE WELD 5 ON PEDESTAL
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1156

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

16

Not Applicable

Job Description/Particulars:
STARBOARD CRANE WELD 5 ON PEDESTAL
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1157

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE BASE TO UPPER DECK
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1158

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE BASE TO UPPER DECK
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1159

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE BASE TO UPPER DECK
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1160

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE BASE TO UPPER DECK
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1161

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE BASE TO UPPER DECK
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1162

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE BASE TO UPPER DECK
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1MTR.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1163

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE BASE TO UPPER DECK
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 500MM X 500MM.
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1164

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 1
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1165

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 1
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1166

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

10

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 1
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1167

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

11

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 4
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1168

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

12

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 4
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1169

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

13

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 4
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1170

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

10th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

14

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 4
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1171

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

15

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 5
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1172

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

16

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 5
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1173

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

17

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 5
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1174

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

18

Not Applicable

Job Description/Particulars:
PORT CRANE WELD 5
EXTERNAL WELDMENT AREA.
WELD SIZE INSPECTED 1 MTR
BEFORE LOAD TEST
PLEASE REFER TO LOCATION DRAWING.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1175

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED OUT ON
WELDMENT AREAS OF NEW SUPPORT BEAM FOR FAST
RESCUE DAVIT DECK.
AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1176

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

11th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Not Applicable

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED OUT ON
WELDMENT AREAS OF NEW SUPPORT TUBULAR FOR FAST
RESCUE DAVIT DECK.
AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

MCGREGOR, THOMAS
ET LEVEL II, MT LEVEL II, PT LEVEL II, UT LEVEL II, IRATA LEVEL I

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1177

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-01

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1178

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-02

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1179

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1180

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1181

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3-01

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1182

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3-02

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1183

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1184

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1185

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4-01

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1186

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4-02

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1187

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1188

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

29th April, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4-04

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING STBD CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1224

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1-01

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1225

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1-02

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1226

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1227

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1-04

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1228

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1-05

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1229

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1-06

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1230

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 1-07

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1231

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-01

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1232

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-02

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1233

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1234

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-05

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1235

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-06

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1236

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-07

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1237

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 2-07

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1238

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3-01

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1239

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3-02

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1240

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1241

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 3-04

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1242

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4-01

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1243

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4-02

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1244

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1245

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 4-04

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1246

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 5-01

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1247

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 5-02

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1248

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 5-03

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1249

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

13th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

Weld 5-04

Not Applicable

Job Description/Particulars:
EDDY CURRENT INSPECTION WAS CARRIED ON THE
WELDING PORT CRANE AFTER LOAD TEST.

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1250

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

B2

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 1 BOTTOM STBD WELD AFTER LOAD
TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1251

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

B2

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 1 BOTTOM PORT WELD AFTER LOAD
TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1252

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

C2

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 1 TOP PORT WELD AFTER LOAD TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1253

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

C2

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 1 TOP STBD WELD AFTER LOAD TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1254

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

B2490

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 4 TOP STBD WELD AFTER LOAD TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1255

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

B2490

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 4 TOP PORT WELD AFTER LOAD TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1256

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

A2490

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 4 BOTTOM STBD WELD AFTER LOAD
TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1257

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

A2490

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 4 TOP STBD WELD AFTER LOAD TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1258

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

A10

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 2 BOTTOM STBD WELD AFTER LOAD
TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1259

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

A10

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 2 TOP STBD WELD
AFTER LOAD TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

OES OILFIELD SERVICES GROUP


EDDY CURRENT INSPECTION CERTIFICATES
Certificate No. 2015-391 / 1260

Office : BRASIL

Date : 26th May, 2015

Invoice Address/Customer:

Rig Name:

PROSAFE PRODUCTION

SAFE CONCORDIA

RUA LAURO MULLER 116, # 1206


RIO DE JANEIRO, BRAZIL 22290-160, BRAZIL

Location:

Date of Inspection :

Client Order No.:

14th May, 2015

532014PO-70240

BRAZIL

Serial No.:

Safe Working Load / Rating:

B9290

Not Applicable

Job Description/Particulars:
PORT CRANE SECTION 2 TOP STBD WELD AFTER LOAD TEST

Material:
CARBON STEEL
Procedure/Work Instruction/Technique:
OES Procedure ID: I 41

Surface Condition:
PAINTED
Acceptance Standard:
BS EN ISO 15549:2010
Equipment

GE PHASEC 3

Serial Number:
801AT75

Bridge Probes Used:

Pencil Probes Used:

ECO 4509/01

978583/04

Equipment Make & Model:

Gain:
47/47

Frequency:
100 KHZ

Type:
GE

Measured Coating Thickness:


1MM

Relative Sensitivity:
1MM SLOT @ 80% FSH

Calibration Block Used:

Calibration Block Serial No.:


ECO 4575/01

GE

Phase (Degrees):
215.0

Results:
NO DEFECTS OR SURFACE BREAKING DISCONTINUITIES FOUND AT THE TIME OF
INSPECTION

Name & Qualification :

Signed/Stamp

SILVA, CARLOS EDUARDO


ET LEVEL II, MT LEVEL II, UT LEVEL II

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier,
repairer, or operator of any warranty, express or implied and OES. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES be
liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in materials, machinery, equipment, or other items other than by defects in
items actually inspected by OES and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES and which are covered by this certificate or report.
The certificate or report and the recommendations contained in it are based upon the conditions and practices observed and information made available to OES personnel. The report does not purport to
list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines
only. No responsibility is assumed for the control or correction of conditions.
OES DUBAI OFFICE P.O. Box 75971, Dubai, United Arab Emirates, Tel: +971 4 326 2822 Fax: +971 4 326 2298;
OES USA OFFICE, 4295 San Felipe, Suite 250 Houston, Texas 77027, USA, Tel: +1 713 960 1339 Fax: +1 713 960 6200;
OES UK OFFICE 37 Albert Street, Aberdeen, AB25 1XU, United Kingdom. Tel: +44 (0)1224 640700 Fax: +44 (0)1224 640900;
OES SINGAPORE OFFICE 237 Alexandra Road, #02-04, The Alexcier, Singapore 159929, Tel: +65 6476 2440 Fax: +65 6251 5582;
OES BRASIL OFFICE Rua Bariloche n 37, Macae, RJ, Brasil, CEP 27.933-260, Tel: +55-22-2773-2714
www.oesgroup.com

PLATE C
WELD 2
WELD 1
PLATE B
PLATE A

C
C1

B
A

C3
B1

C2

A1

A3
B3
B2

A2

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

HORIZONTAL BRACING FORWARD


AND AFT DRAWING LOOKING PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC01

PLATE C
WELD 13
WELD 12
PLATE B
PLATE A

C1
C

B1
A1

C2
B

C3

A2
B2

A3

B3

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

HORIZONTAL BRACING FORWARD


AND AFT DRAWING LOOKING STARBOARD

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC02

WELD 7
WELD 6
WELD 5
WELD 4
WELD 3

STARBOARD

PORT

WELD 11
WELD 10
WELD 9
WELD 8

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

HORIZONTAL BRACING FORWARD


AND AFT DRAWING LOOKING PORT

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC03

WELD C
PLATE B
PLATE A

C1
C
STARBOARD

B
A

B1
A1

C3
B3

C2

A3

B2
A2

C1
B1

A1

PORT

B
A
C2
C3

A2
A3

B2
B3

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

HORIZONTAL BRACING CENTER

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC04

PORT
FWD
STBD

AFT

500mm

1mtr

500mm

7
500mm

500mm

1.mtr

10

WELD 1

1.mtr

1mtr

ENTRANCE TO PEDESTAL

1.mtr

500mm

PROJECT : EDDY CURRENT INSPECTION

500mm
1

500mm

1mtr

500mm

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

INSPECTOR

DRAWN BY

SCALE: NOT TO SCALE

REVISION

APPROVED BY

PORT CRANE PEDESTAL EXTERNAL

T. McGREGOR / R.BERALDINI

KALBI SAMILIN

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC05

PORT
FWD
STBD

AFT

500mm

1mtr

500mm

8
ENTRANCE TO DEPESTAL

500mm

500mm
PEDESTAL BASE

1.mtr

12

1mtr

1.mtr

WELD 1

11

1.mtr

1mtr

10

1.mtr

500mm

PROJECT : EDDY CURRENT INSPECTION

500mm

1mtr

500mm

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

500mm

REVISION

PORT CRANE PEDESTAL EXTERNAL

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC06

150mm
4

150mm

WELD 1

150mm

ENTRANCE TO PEDESTAL

PEDESTAL BASE

2
150mm

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

MPI INSPECTION AREA PORT CRANE


PEDESTAL BASE AND WELD 1 INTERNAL

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC07

PORT
FWD
STBD

AFT

ENTRANCE TO PEDESTAL

PEDESTAL BASE

1mtr

WELD 1

1mtr

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

MPI INSPECTION AREA STARBORD CRANE


PEDESTAL BASE AND WELD 1 INTERNAL

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC08

STBD
AFT
PORT

FWD

BOTTOM ENTRANCE TO PEDESTAL

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

MPI INSPECTION AREA PORT CRANE


PEDESTAL WELD 5 INTERNAL

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC09

PORT
FWD
STBD

AFT

15mm

15mm

BOTTOM ENTRANCE TO PEDESTAL

15mm

15mm

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

MPI INSPECTION AREA PORT CRANE


PEDESTAL WELD 5 INTERNAL

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC10

STBD
AFT
PORT

FWD

1 meter EVERY INSPECTION POINT CRANE PEDESTAL

17
16

18

WELD 5

14

WELD 4

15

13
12
11

WELD 3

WELD 2

WELD 1

ENTRANCE TO PEDESTAL

BASE TO DECK

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

SCALE: NOT TO SCALE

REVISION

INSPECTION AREA CRANE


INTERNAL AND EXTERNAL

INSPECTOR

T. McGREGOR / R.BERALDINI

DRAWN BY

KALBI SAMILIN

APPROVED BY

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC11

STBD
AFT
PORT

FWD

15
14

16

WELD 5

13

WELD 4

WELD 3

WELD 2

WELD 1

ENTRANCE TO PEDESTAL

BASE TO DECK

PROJECT : EDDY CURRENT INSPECTION

DESCRIPTION /
LOCATION

INSPECTION DATE : MARCH 2015

INSPECTOR

DRAWN BY

SCALE: NOT TO SCALE

REVISION

APPROVED BY

INSPECTION AREA PORT CRANE


INTERNAL AND EXTERNAL
T. McGREGOR / R.BERALDINI

KALBI SAMILIN

JOSEPH KING

NOTE: THE LOCATOR DRAWINGS ARE FOR REFERENCE OF CERTIFIED AND NON CONFORMANT EQUIPMENT WHICH HAS
BEEN REPRESENTED TO COINCIDE WITH THE REPORTS FORMULATED FOR EACH SURVEY.

OES OILFIELD SERVICES GROUP


TEL: +5522 2773 2714
RUA BARILOCHE
NO 37, CAVALEIROS MACAE,
RJ, BRASIL
www.oesgroup.com

WELD

EDDY CURRENT CARRIED OUT


VESSEL / FACILITY

SAFE CONCORDIA

SEMI SUB

JOB No. / DWG No.

15-391

EC12

Appendix

OES Accreditation

Report No.: 15-391R


Contract No.: 15-391
Date of Inspection: 28 Apr 2015

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

OES Accreditation

DNV ISO 9001:2008

DNV Certificate
Thickness Gauging

ABS Certificate
Thickness Gauging

LEEA

Revision No: 1
Reviewed by: A. Carmo

IADC

Date of Issue: 26 May 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and OES Ltd.
Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in
materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or
report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Inspectors Qualifications / CVs

Thomas McGregor

Report No.: 15-391R


Contract No: 15-391
Date of Inspection: 28 Apr 2015
Thomas McGregor

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

Lead Inspector

Current Qualifications:
ET Level 2
UT Level 2
PT Level 2
MT Level 2
IRATA Ropes Access Level 1
LEI Part 1
This is a summary of the inspection/audit Contracts Thomas McGregor has been involved in since joining OES.
Client
Prosafe Production

Job Description
Non-Destructive Testing + UT
Gauging Inspection

Rig
Safe Concordia

Area
Brazil

Type
Semi Sub

Duration
40 Days

Date
03.15

Prosafe Production

UT Gauging Inspection

Safe Concordia

Brazil

Semi Sub

13 Days

01.15

Prosafe Production

Non-Destructive Testing + UT
Gauging Inspection

Safe Concordia

Brazil

Semi Sub

30 Days

11.14

Paragon Offshore

Derrick Inspection

DPDS-3

Brazil

Drillship

6 Days

10.14

Paragon Offshore

Derrick Inspection

DPDS-3

Brazil

Drillship

13 Days

09.14

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 Apr 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and
OES Ltd. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of
or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are
covered by this certificate or report.
The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Rodolfo Beraldini Lima

Report No.: 15-391R


Contract No: 15-391
Date of Inspection: 28 Apr 2015
Rodolfo Beraldini Lima

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

Inspector

Current Qualifications:
IRATA Ropes Level 2
H2S
HUET
This is a summary of the inspection/audit contracts which Rodolfo Beraldini Lima has been involved in since joining OES.
Client

Job Description

Rig

Area

Type

Duration

Date

Prosafe Production

Non-Destructive Testing + UT
Gauging Inspection

Safe Concordia

Brazil

Semi Sub

14Days

04.15

Prosafe Production

Non-Destructive Testing + UT
Gauging Inspection

Safe Concordia

Brazil

Semi Sub

13Days

03.15

Prosafe Production

Non-Destructive Testing + UT
Gauging Inspection

Safe Concordia

Brazil

Semi Sub

14 Days

02.15

Prosafe Production

Non-Destructive Testing + UT
Gauging Inspection

Safe Concordia

Brazil

Semi Sub

13 Days

01.15

Prosafe Production

Non-Destructive Testing + UT
Gauging Inspection

Safe Concordia

Brazil

Semi Sub

30 Days

11.14

Noble Do Brasil
Ltda

Lifting Gear Inspection

Bully II

Brazil

Drillship

13 Days

10.14

Pacific Drilling
Services, Inc.

Non-Destructive Testing

Mistral

Brazil

Drillship

12 Days

09.14

Noble Do Brasil
Ltda

Lifting Gear Inspection

Bully II

Brazil

Drillship

17 Days

07.14

Ensco

Rope Access & NDT Inspection

Ensco 7500

Brazil

Semi Sub

02 Days

07.14

Aker Solutions do
Brasil Ltda

Direct Cost - 14-788

Mylos

Brazil

Semi
Submersible

14 Days

04.14

BassDrill

Equipment rental-14-234

Atlantica BETA

Brazil

6 Days

04.14

BassDrill

Equipment rental-14-234

Atlantica BETA

Brazil

1 Day

03.14

Ocean Rig

Direct Cost - 15-566

Corcovado

Brazil

12 Days

03.14

ETESCO

Equipment rental-14-190

Aban Abraham

Brazil

9 Days

02.14

ETESCO

Dropped Objects - Rope Access

NS-38

Brazil

Semi
Submersible
Semi
Submersible
Semi
Submersible
Semi
Submersible
Drillship

6 Days

02.14

ETESCO

Dropped Objects - Rope Access

NS-38

Brazil

Drillship

5 Days

01.14

Ensco

Lifting Gear Inspection

DS-4

U.S.A

Drillship

18 Days

01.14

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 Apr 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and
OES Ltd. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of
or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are
covered by this certificate or report.
The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Thiago Neves

Report No.: 15-391R


Contract No: 15-391
Date of Inspection: 28 Apr 2015

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

Thiago Neves
Inspector
Current Qualifications:
IRATA Ropes Access Level 1
Working at Heights
HUET
CBSP
This is a summary of the inspection/audit contracts Thiago Neves has been involved in since joining OES.
Client

Job Description

Rig

Area

Type

Duration

Date

Prosafe Production

Non-Destructive Testing + UT
Gauging Inspection

Safe Concordia

Brazil

Semi Sub

21 Days

03.15

Ocean Rig

Fixed Contract

Mykonos

Brazil

Semi-Sub

12 Days

02.15

Paragon Offshore

Six Monthly Equipment & Crane


Inspection
Six Monthly Equipment & Crane
Inspection

DPDS-3

Brazil

Drillship

8 Days

12.14

Bully II

Brazil

Drillship

3 Days

11.14

Noble Do Brasil Ltda

Six Monthly Equipment & Crane


Inspection

Bully II

Brazil

Drillship

9 Days

10.14

Noble Do Brasil Ltda

Six Monthly Equipment & Crane


Inspection

Bully II

Brazil

Drillship

7 Days

09.14

Ocean Rig

Fixed Contract

Mylos

Brazil

Semi-Sub

3 Days

09.14

Ocean Rig

Fixed Contract

Mylos

Brazil

Semi-Sub

14 Days

08.14

Ocean Rig

Fixed Contract

Mylos

Brazil

Semi-Sub

14 Days

07.14

Ocean Rig

Fixed Contract

Mylos

Brazil

Semi-Sub

14 Days

05.14

Ocean Rig

Fixed Contract

Mylos

Brazil

Semi-Sub

14 Days

04.14

Ocean Rig

Fixed Contract

Mylos

Brazil

Semi-Sub

13 Days

03.14

ETESCO

Six Monthly Equipment & Crane


Inspection

Aban Abraham

Brazil

Semi-Sub

9 Days

02.14

Transocean

Non-Destructive Testing

Brazil

Drillship

19 Days

01.14

Transocean

Non-Destructive Testing

Petrobras
10000
Petrobras
10000

Brazil

Drillship

10 Days

12.13

Dolphin Drilling

Fixed contract - Painting

Brazil

N/A

18 Days

09.13

BP Energy do Brasil Ltda

Six Monthly Equipment & Crane


Inspection

Borgny
Dolphin
Polvo A

Brazil

Drillship

11 Days

08.13

Noble Do Brasil Ltda

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 Apr 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and
OES Ltd. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of
or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are
covered by this certificate or report.
The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

&DUORV(GXDUGR6LOYD

Report No.: 15-391R


Contract No: 15-391
Date of Inspection: 28 Apr 2015
Carlos Eduardo Silva

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

Inspector

Current Qualifications:
IRATA Rope Access Level 1
HUET
This is a summary of the inspection/audit contracts which Carlos Eduardo Silva has been involved in since joining OES.
Client

Job Description

Rig

Area

Type

Duration

Date

Prosafe Production

UT Gauging Inspection

Safe Concordia

Brazil

Semi Sub

16 Days

04.15

ETESCO

Dropped Objects Survey

NS-38

Brazil

Drillship

06 Days

04.15

ETESCO

Six Monthly Equipment


& Crane Inspection

NS-7

Brazil

Drillship

13 Days

02.15

Prosafe Production

UT Gauging Inspection

Safe Concordia

Brazil

Semi Sub

13 Days

01.15

Ocean Rig

Fixed Contract

Mylos

Brazil

Drillship

13 Days

12.14

Paragon Offshore

Derrick Maintenance

DPDS-3

Brazil

Drillship

8 Days

12.14

Noble Do Brasil Ltda

None-Destructive
Inspection Survey
Six Monthly Equipment
& Crane Inspection
Six Monthly Equipment
& Crane Inspection
Six Monthly Equipment
& Crane Inspection
Load Testing - Padeye
Inspection
Six Monthly Equipment
& Crane Inspection
Six Monthly Equipment
& Crane Inspection+
NDT

Bully II

Brazil

Drillship

2 Days

11.14

Mylos

Brazil

Drillship

2 Days

10.14

NS-38

Brazil

Drillship

17 Days

09.14

Atlantica Beta

Brazil

Drillship

2 Days

07.14

Max Smith

Brazil

Semi-Sub

3 Days

05.14

Ensco 7500

Brazil

Semi-Sub

19 Days

04.14

Norbe VI

Brazil

Drillship

25 Days

02.14

Ocean Rig
ETESCO
Bass Drill
Noble Do Brasil Ltda
Ensco
Odebrecht Oleo e Gas Ltda

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 Apr 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and
OES Ltd. Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of
or any defect in materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are
covered by this certificate or report.
The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Standards Referenced

Report No.: 15-391R


Contract No.: 15-391
Date of Inspection: 28 Apr 2015

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

Appendix
Standards Reference List
The OES inspection report includes by reference, either in total or in part, specific industry standards. These are standards
that are taken and adopted at the time of the survey. Requirements of other standards included by reference in this report are
essential to the safety and inspection techniques adhered to by OES.
Other nationality or internationally recognised standards may be used provided it can be shown that they meet or exceed the
requirements of the standards stated in the reports.
Standards and abbreviations used in the OES six monthly surveys.
API RP 2A-WSD

API 2C

RECOMMENDED PRACTICE FOR PLANNING, DESIGNING AND CONSTRUCTION FIXED


OFFSHORE PLATFORMS WORKING STRESS DESIGN
RECOMMENDED PRACTICE FOR THE OPERATION AND MAINTENANCE OF OFFSHORE
CRANES
RECOMMENDED PRACTICE FOR MAINTENANCE, AND USE OF DRILLING WELL
SERVICING STRUCTURES
RECOMMENDED PRACTICE FOR PROCEDURES FOR INSPECTION, MAINTENANCE,
REPAIR AND REMANUFACTURE OF DRILLING EQUIPMENT
RECOMMENDED PRACTICE FOR PROCEDURES FOR INSPECTION, MAINTENANCE,
REPAIR AND REMANUFACTURE OF HOISTING EQUIPMENT
RECOMMENDED PRACTICE ON APPLICATION CARE, AND USE OF WIRE ROPE FOR
OILFIELD SERVICE
RECOMMENDED PRACTICE FOR OCCUPATIONAL SAFETY FOR OIL AND GAS WELL
DRILLING AND SERVICING OPERATIONS
SPECIFICATION FOR OFFSHORE PEDESTAL MOUNTED CRANES

API 5L

SPECIFICATION FOR LINE PIPE

API 8C

ASME B30.7

SPECIFICATION FOR DRILLING AND PRODUCTION HOISTING EQUIPMENT (PSL1 &


PSL2)
PRESSURE VESSEL INSPECTION CODE: IN-SERVICE INSPECTION, RATING, REPAIR AND
ALTERATION
BASE-MOUNTED DRUM HOISTS

BS 2330

TECHNICAL CHARACTERISTICS & TESTING FOR FORKLIFT TRUCKS AND FORK ARMS

BS 2853

THE DESIGN AND TESTING OF STEEL OVERHEAD RUNWAY BEAMS

BS 3551

SPECIFICATION FOR ALLOY STEEL SHACKLES

BS 7121 PT 2
BS EN 571-1

CODE OF PRACTICE FOR SAFE USE OF CRANES - INSPECTION, TESTING &


EXAMINATION
NON-DESTRUCTIVE TESTING - PENETRANT TESTING - GENERAL PRINCIPLES

BS EN 9934-1

NON-DESTRUCTIVE TESTING - MAGNETIC PARTICLE TESTING - GENERAL PRINCIPLES

BS EN 12079

OFFSHORE CONTAINERS AND ASSOCIATED LIFTING SETS

API RP 2D
API RP 4G
API RP 7L
API RP 8B
API RP 9B
API RP 54

API 510

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 May 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and OES Ltd.
Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in
materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or
report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Report No.: 15-391R


Contract No.: 15-391
Date of Inspection: 28 Apr 2015

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

BS EN 12084

NON-DESTRUCTIVE TESTING - EDDY CURRENT TESTING - GENERAL PRINCIPLES

BS EN 13157

CRANES - SAFETY HAND POWERED LIFTING EQUIPMENT

BS EN 13414 PT 2

STEEL WIRE ROPE SLINGS SAFETY - SPECIFICATION FOR INFORMATION

FEM 9.751

POWER DRIVEN HOISTS AND WINCHES

ABS

AMERICAN BUREAU OF SHIPPING

ANSI

AMERICAN NATIONAL STANDARDS INSTITUTE

API

AMERICAN PETROLEUM INSTITUTE

ASME

AMERICAN SOCIETY OF MECHANICAL ENGINEERS

ASNT

AMERICAN SOCIETY OF NON-DESTRUCTIVE TESTING

ASTM

AMERICAN SOCIETY FOR TESTING AND MATERIALS

AWS
BSI

AMERICAN WELDING SOCIETY - GUIDE FOR THE NON-DESTRUCTIVE EXAMINATION


OF WELDS
BRITISH STANDARDS INSTITUTE

DNV

DET NORSKE VERITAS

FEM

FEDERATION EUROPEENNE DE LA MANUTENTION

IADC

INTERNATIONAL ASSOCIATION DRILLING CONTRACTORS

IMCA

INTERNATIONAL MARINE CONTRACTORS ASSOCIATION - THE INITIAL AND PERIODIC


EXAMINATION, TESTING AND CERTIFICATION OF DIVING PLANT AND EQUIPMENT
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION

ISO
LEEA
LOLER (S.I.2307)

LIFTING EQUIPMENT ENGINEERS ASSOCIATION - CODE OF PRACTICE FOR THE SAFE


USE OF LIFTING EQUIPMENT
LIFTING OPERATIONS AND LIFTING EQUIPMENT REGULATIONS

OSHA

OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION

PUWER (S.I.2306)

THE PROVISION AND USE OF WORK EQUIPMENT REGULATIONS

SOLAS (2001)

SAFETY OF LIFE AT SEA REGULATIONS SIXTH EDITION 2001

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 May 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and OES Ltd.
Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in
materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or
report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Inspection Equipment Calibration


Certificates

Report No.: 15-391R


Contract No.: 15-391
Date of Inspection: 28 Apr 2015

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

Appendix - Electro Magnet Calibration Certificate

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 May 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and OES Ltd.
Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in
materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or
report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Report No.: 15-391R


Contract No.: 15-391
Date of Inspection: 28 Apr 2015

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

Appendix - Electro Magnet Calibration Certificate

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 May 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and OES Ltd.
Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in
materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or
report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Report No.: 15-391R


Contract No.: 15-391
Date of Inspection: 28 Apr 2015

Client: Prosafe Production


Rua Lauro Muller 116, # 1206
Rio de Janeiro, Brazil 22290-160, Brazil

Vessel/Site: Safe Concordia


Location: Brazil

Appendix - Eddy Current Calibration Certificate

Revision No: 1
Reviewed by: A. Carmo

Date of Issue: 26 May 2015

Inspected by: T. McGregor/R. Lima/T. Neves/C. Silva


Authorised by: J. King

This certification or report is granted or issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, seller, supplier, repairer, or operator of any warranty, express or implied and OES Ltd.
Liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no circumstances shall OES Ltd. be liable for any injury or damage to any person or property occurring by reason of negligent operation, misuse, of or any defect in
materials, machinery, equipment, or other items other than by defects in items actually inspected by OES Ltd And ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by OES Ltd and which are covered by this certificate or
report. The certificate or report and the recommendations contained within it are based upon the conditions and practices observed and information made available to OES Ltd personnel. The report does not purport to list all hazards or faulty conditions not to indicate
that other hazards or faulty conditions exist. Severity ratings on the criteria shown in this report are intended as guidelines only. No responsibility is assumed for the control or correction of conditions.

Você também pode gostar