POWERLOGIC Power Monitoring and Control Systems

Meter Comparison Table

Feature

Value

Phase Current

A, B, C, N

Volts, L-L

A-C, C-B, C-A

Volts, L-N

A-N, B-N, C-N

Real Power (kW)

A, B, C, total

Reactive Power (kVAR)

A, B, C, total

Apparent Power (kVA)

A, B, C, total

Power Factor (true)

A, B, C, total

Enercept Meters

3 total

Reactive Energy (kVARh)

3 total

Apparent Energy (kVAh)

3 total

Energy Accumulation Modes

Signed, Absolute, energy in, energy out

PM600

PM620

PM650

CM2150

CM2250

CM2350

CM2450

CM4000

kf

kq
k
k
kf
kf
kf
k

kq
k
k
k
k
k
k
k
k
k
k
k
k

k
k
k
k
k
k
k
k
k
k
k
k
k

k
k
k
k
k
k
k
k
k
k
k
k
k

k
k
k
k
k
k
k
k
k
k
k
k
kp

k
k
k
k
k
k
k
k
k
k
k
k
kp

k
k
k
k
k
k
k
k
k
k
k
k
kp

k
k
k
k
k
k
k
k
k
k
k
k
kp

k
k
k
k
k
k
k
k
k
k
k
k
k

M
P

M
P

M
P

Opt

Opt

Opt

k
k

k
k
k

k
k
k

k
k
k

k
k
k

Opt

k
k
k

k
k
k

k
k
k

k
k
k

k
k
k

k
k
k

k
k
k

k
k

k
k

k
k

k
k

k
k

k
k

64

128

128

512

k
k

k
k
k
k

KYZ Output
Communications

Modbus RTU (M)


POWERLOGIC (P)

Front Display
THD, Voltage & Current

A, B, C

Current Demand

A, B, C, present & peak

Power Demand
(kWd, kVARd, kVAd))

3 total, present & peak

Date/time stamping

Peak demands, power up/restart, resets

Predicted Power Demand

kW, kVAR, kVA

Advanced Demand Options

Synch to comms, sliding block calculation

Onboard Alarms

Under/over conditions.
phase unbalance conditions

Min/Max Readings

Frequency, current, voltage, power,


power factor, THD

kc

kj

Data and Event Logs

Downloadable Firmware
Waveform Capture

Circuit Monitors

Enhanced

Frequency
Real Energy (kWh)

Power Meters

Basic

Samples per cycle

Sag/Swell Detection
Programmable
Transient Detection
Sequence of Events Recording
Revenue Accuracy, ANSI

C12.16

C12.16

C12.16

C12.16

C12.16

C12.16

C12.16

C12.20s

Accuracy (of Reading)

Power/Energy
Current/Voltage

1%

1%

.5%
.25%

.5%
.25%

.5%
.25%

.4%
.2%

.4%
.2%

.4%
.2%

.4%
.2%

.2%
.1%

Harmonic Response

Based on sample rate

10

10

31

31

31

31

31

31h

31h

127

k
k

k
k

480

480

600

600

600

180v

180v

180v

180v

600v

UL Listed
CUL
CSA, CE, NOM
Voltage Input

Direct Connect maximum

CTs Included
q
f
p
j
v
s
h
c

Neutral not available


Total power only. Per phase power unavailable.
With addition of IOM.
Min/max real power only.
With addition of PT's unit can monitor up to 1.7MV.
Plus revenue metering security switch and tab for wire seal.
Waveform capture up to 63rd harmonic.1. Neutral not available.
3 phase total only.

POWER MONITORING AND


CONTROL

k
k

4-2

2000 Square D
All Rights Reserved

3/00

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


Energy and Enercept Meters
Class 3020, 3050
PowerLogic Energy Meter
The Energy Meter provides the features required for sub-metering along with pricing and convenience that removes the
hurdle from getting the information that is needed to make better decisions. The Energy Meter can be used for tenant
sub-metering applications where the property manager or building owner may not initially desire a full blown energy
management/information system. The Energy Meter can also be used in applications where load dis-aggregation is
required. The Basic Energy Meter acts as a standalone meter with display. The Enhanced Energy Meter adds the
capability of an optional communication board along with voltage input up to 600 Vac.
A multi segment backlit LCD display presents energy consumption in kWh and MWh as applicable. In addition, the
display automatically scrolls through the following variables:
k kW
k KVAR
k PF
k Volts per phase and 3 phase averagec
k Amps per phase and three phase average c
c Per phase values are not displayed on single phase meters.

The compatible current transformers (CT) are split-core style for ease of installation. The CTs come in 125 A, 225 A,
800 A, 1600 A , and 5000 A ranges. The system accuracy including these compatible CTs is 1% of reading from 2% to
100% of the rated current of the CTs.
The Energy Meter has an Infrared Serial port so that data can be retrieved from the meter using a PDA with infrared
capabilities.
Catalog Number

Description

EM-B
EM-E
EM-COB
EM-CT01
EM-CT02

Energy Meter Basic Model


Energy Meter Enhanced Model
Energy Meter Comms Option Board (for Enhanced Model only)
Energy Meter CT, 125A
Energy Meter CT, 225A

EM-CT08
EM-CT16
EM-CT50

Energy Meter CT, 800A


Energy Meter CT, 1600A
Energy Meter CT, 5000A

PowerLogic Enercept Meter


Enercept Meters consist of three interconnected split core CTs with the metering and communication electronics built
into one of the CT housings. Simply snap on the CTs, connect the voltage inputs and communication lines, and
installation is complete. There are two versions of the Enercept Meter Basic and Enhanced. They differ only in the
amount of metering information provided. The Basic meter reports power and energy only. The Enhanced version
delivers 26 energy parameters, including power, energy, demand, volts, amps, power factor, and reactive power. Both
versions can be used on either three phase or single phase systems.
Enercept Meters employ the Modbus RTU 2-wire communication protocol and can utilize the same communication
network and POWERLOGIC System Manager software as other POWERLOGIC devices. Data from the Enercept
Meters can be presented within System Manager Software in tabular or graphical format, used for alarming and historical
logging and trending, along with producing reports. This makes the Enercept Meter the perfect unit for sub-metering
your entire facility.
Description

Price

B01-2
B03-2
B04-3
B08-3
B08-4

Enercept Meter, Basic 100 A, 1.25" x 1.51" ID


Enercept Meter, Basic 300 A, 1.25" x 1.51" ID
Enercept Meter, Basic 400 A, 2.45" x 2.89" ID
Enercept Meter, Basic 800 A, 2.45" x 2.89" ID
Enercept Meter, Basic 800 A, 2.45" x 5.50" ID

$ 750.
773.
795.
818.
840.

B16-4
B24-4
E01-2
E03-2
E04-3

Enercept Meter, Basic 1600 A, 2.45" x 5.50" ID


Enercept Meter, Basic 2400 A, 2.45" x 5.50" ID
Enercept Meter, Enhanced 100 A, 1.25" x 1.51" ID
Enercept Meter, Enhanced 300 A, 1.25" x 1.51" ID
Enercept Meter, Enhanced 400 A, 2.45" x 2.89" ID

863.
885.
1000.
1030.
1060.

E08-3
E08-4
E16-4
E24-4
3050 2W485C

Enercept Meter, Enhanced 800 A, 2.45" x 2.89" ID


Enercept Meter, Enhanced 800 A, 2.45" x 5.50" ID
Enercept Meter, Enhanced 1600 A, 2.45" x 5.50" ID
Enercept Meter, Enhanced 2400 A, 2.45" x 5.50" ID
2-Wire only 232-485 Converter

1090.
1120.
1150.
1180.
75.

3050 EMBK-3
3050 ME-SVR

Enercept Mounting Brackets (Set of 3)


Modem Eserver, Data Logger

POWER MONITORING AND


CONTROL

Catalog Number

72.
676.

3/00

PL1

Discount
Schedule

2000 Square D
All Rights Reserved

4-3

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Monitoring and Control Systems


Metering
Class 3020
Enercept Communications
There are multiple methods for communicating with the
Enercept Meter. The Enercept Meter can be tied directly
to a computer, can be tied to an E-Server for data logging,
or can be connected to a POWERLOGIC network with
circuit monitors and power meters.

3050 2W485C

The E-Server is an energy information server that is


perfect for:

POWERLOGIC
PMX or SMS Software

k Energy aggregation of remote sites


k Submetering/metering of large facilities
Enercept Meters

k Energy allocation on campuses/bases


It is ideal for remote monitoring applications as it provides
a flexible, cost effective means to:

E-Server

k Gather energy usage information from multiple


sources
k Time and date stamp information and store it in
battery backed memory (SRAM)

Phone Line

k Accessible from servers (PCs) via modem or local


RS232
The E-Server accepts inputs from up to 20 Enercept
Meters and consumption pulses from up to four other
sources. The E-Servers ability to accept standard pulsed
inputs allows for easy integration of energy usage from
water, gas, utility, and sewage meters.

Other Devices

4W-2W Converter

Power Meters
The POWERLOGIC Power Meter is capable of replacing a full complement of basic analog meters. This cost effective,
true RMS meter can operate as a stand-alone device or as part of a POWERLOGIC Power Monitoring and Control
System to help reduce energy and maintenance costs by providing valuable information.
k Certified ANSI C12.16 revenue accuracy

Description

k Display mounts in standard 1% meter cutout


k Flexible mounting with separate meter and display
POWER MONITORING AND
CONTROL

Power Meter with


Display

k Direct connect up to 600 Vac


k Optional 2-Line LCD Display
k POWERLOGIC & Modbus RS-485 communications
k 0.25% accuracy on current and voltage
k On-board event and data logging

Catalog
Number

Price

Power Meter Module, Basic Instrumentation

PM600

$1129.

Power Meter Module, Basic Instrumentation, plus


Demand, THD, Date/Time Stamping, Neutral
Current

PM620

1360.

Power Meter Module, Min/Max, Alarms, Event and


Data Storage, plus PM-620 Features

PM650

1678.

Power Meter Display with 1 Foot Cable


Serial cable from PM to Display (4ft)
Serial cable from PM to Display (12ft)
Serial cable from PM to Display (30ft)

PMD32
SC104
SC112
SC130

318.
32.
53.
101.

k UL Listed, CSA Approved, CE Marking, NOM


Approved

POWERLOGIC is a Registered Trademark of Square D Company or related companies.

4-4

2000 Square D
All Rights Reserved

PL1

Discount
Schedule

3/00

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


Metering
Class 3020, 3090
The POWERLOGIC Circuit Monitor is a multi-function, digital instrumentation, data acquisition and control device
capable of replacing a variety of meters, relays, transducers and other components. Over 50 metered values plus
extensive Min/Max data can be viewed on the six-digit LED display. Each Circuit Monitor offers true RMS metering and
RS-485 communications standard. Models CM-2150 and above offer 0.2% accuracy true RMS metering and other
powerful features such as automatic relay control, waveform capture, on-board event and data logging, and
programmable logic for special applications like custom data logging and control function. On-board memory can be
expanded to add 512K or 1024K to the CM-2150 and above. Optional add-on input/output modules provide status inputs,
a pulse output, relay outputs and analog inputs and outputs.
POWERLOGIC Circuit Monitors
k Certified ANSI C12.16 revenue accuracy
k True RMS Metering through the 31st harmonic
Circuit Monitor

k High accuracy: 0.2% on current and voltage


k Power quality readings displayed: THD and K-Factor
k Harmonic Analysis Data through 63rd harmonic
k Automatic Alarm/Relay control
k On-board event and data logging
k Waveform capture
k UL Listed, CSA Approved, CE Marking, NOM Approved
k MV-90 compatible
Circuit Monitors and Accessories, except I/O Options
Class
3020
3020
3020
3020
3020
3020
3020
3020
3020
3020
3020
3020
3020
3020
3020
3090
3090
3090
3090
3090
3090
3090

Catalog No.
CM2150
CM2250
CM2350
CM2450
CM2150512K
CM2250512K
CM2350512K
CM2450512K
CM21501024K
CM22501024K
CM23501024K
CM24501024K
CM2000U
CMMEM512K
CMMEM1024K
VPM277C1
CPM48
RTM317
SMA220
CMA100
CMA110
OCI2000

Description
Circuit monitor with full instrumentation (0.2% accuracy), on-board data logging, 100K memory
Circuit monitor with full instrumentation, CM2150 features, and waveform capture
Circuit monitor with full instrumentation, CM2250 features, and disturbance monitoring
Circuit monitor with full instrumentation, CM2350 features, and programmable logic
Circuit monitor with full instrumentation (0.2% accuracy), on-board data logging, and 612K memory
Circuit monitor with full instrumentation, CM2150 features, waveform capture, and 612K memory
Circuit monitor with full instrumentation, CM2250 features, disturbance monitoring, and 612K memory
Circuit monitor with full instrumentation, CM2350 features, programmable logic, and 612K memory
Circuit monitor with full instrumentation (0.2% accuracy), on-board data logging, and 1124K memory
Circuit monitor with full instrumentation, CM2150 features, waveform capture, and 1124K memory
Circuit monitor with full instrumentation, CM2250 features, disturbance monitoring, and 1124K memory
Circuit monitor with full instrumentation, CM2350 features, programmable logic, and 1124K memory
Circuit monitor firmware upgrade kit
Circuit monitor 512K memory upgrade kit
Circuit monitor 1024K memory upgrade kit
Voltage power module for circuit monitor (Series 2000), 480Y/277 V
Control power module for circuit monitor (Series 2000), 18-60 Vdc
Ride through module for circuit monitor (Series 2000)
Surface-mounting adapter with hinged cover for circuit monitor (CM2000)
Mounting collar for circuit monitor (CM2000)
CM2000 Mounting adapter with accessory compartment
Front panel optical communications interface for circuit monitor (CM2000)

Price
$2894.
3869.
4547.
5247.
3389.
4364.
5042.
5742.
3669.
4644.
5322.
6022.
245.
495.
775.
231.
648.
376.
178.
86.
144.
773.

Input/Output Options for Circuit Monitor

I/O Module with 1 input and 1 output


I/O Module with 8 inputs and 1 output
I/O Module with 4 inputs and 4 outputs
I/O Module with 2 analog and 8 digital
I/O Module with 2 analog and 8 digital
I/O Module with 8 analog and 8 digital
I/O Module with 8 analog and 8 digital
2' I/O Ribbon Cable Extension With Mounting Hardwaref
CM-2000 Ethernet Communications Modulek
Remote mounted Ethernet Communications Modulek

Catalog
Number
IOM11
IOM18
IOM44
IOM441120
IOM441101
IOM444420
IOM444401
RIO110
ECM2000
ECMRM

Price
$ 198.
456.
523.
1124.
1124.
1712.
1712.
114.
1325.
1375.

Status inputs can be used as counters, demand synch pulse inputs, and so on.
Can be used with 3090 CMA-110.
Form C mechanical relay outputs.
Supports other POWERLOGIC compatible devices.

q
f
c
k

Digital I/O
Analog I/O
Status
Pulse
Relay
0-5 Vdc
4-20 mA 0-1 mA
Inputsq Outputs Outputsc or 4-20 mA Input Output Output
1
1

8
1

4
1
3

4
1
3
1
1

4
1
3
1

1
4
1
3
4
4

4
1
3
4

POWER MONITORING AND


CONTROL

Description

POWERLOGIC is a Registered Trademark of Square D Company or related companies.

3/00

PL1

Discount
Schedule

2000 Square D
All Rights Reserved

4-5

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


Metering
Class 3020, 3090
The POWERLOGIC Circuit Monitor CM4000 is a multi-function digital metering and monitoring device capable of
replacing a variety of meters, relays, transducers, and other components. Data available for local viewing includes
metered values plus extensive min/max, alarm, and analog/digital input data. Circuit Monitor data is available for viewing
and recording via standard RS-485, RS-232, or optional Ethernet communications. Two 4-line x 20-character display
options are available with user customizable displays. The CM4000 offers 0.1% accuracy, true RMS metering and other
powerful features such as 512 points/cycle waveform capture, sag/swell monitoring, waveshape fault monitoring,
sequence of events recording, and configurable I/O. The CM4000 can be equipped with either the standard current/
voltage module (CVM) for high accuracy metering or the transient detection version of the current/voltage module
(CVM-T) for detecting and recording high speed voltage transients. The CVM-T and the CVM are interchangeable on
any CM4000.

POWERLOGIC Circuit Monitor 4000


k True RMS metering through the 127th harmonic

k Field installable digital I/O card

k ANSI C12.20 Revenue Accuracy

k Field installable modular analog/digital I/O extender

k Neutral to ground voltage metering

k Revenue metering security switch and tab for wire


seal

k Simultaneous communications port operation


k Standard 1 RS-485 and 1 RS-232 Modbus RTU
communications port (38.4 KBaud)

k Sag/swell disturbance monitoring

k Optional field installable Ethernet Communications


Card with standard web pages

k Extended waveform capture (up to 30 sec)

k Two option card slots for field installable cards

k High speed transient voltage detection and recording

k Wiring diagnostics performed at user request


k No PTs required up to 600 V

k Sequence of events recording using GPS


synchronization technology

k Standard 8 Mb of non-volatile memory (field


upgradeable)

k UL Listed, CSA Approved, CE Marking, NOM


Approved, FCC compliant

k Waveform capture with up to 512 samples/cycle


k Oscillatory transient detection and recording

k Standard pulse output (KYZ)

POWERLOGIC Circuit Monitor 4000 Optional Displays


k High Visibility remote VF (vacuum fluorescence)
display with I/R communications port

k Displays metering data, min/max values, alarms,


inputs

k Remote LC (liquid crystal) display with backlighting


also available
Circuit Monitor 4000

k Optional user configurable display screens

Description
Instrumentation, On-board Data Logging Waveform Capture, Disturbance Recording, Configurable I/O, 0.1% Accuracy
Same as CM-4000 plus Impulsive Transient Detection

Catalog No.

Priceq

CM4000
CM4000T

Accessories for Circuit Monitor 4000

POWER MONITORING AND


CONTROL

Accessory

Catalog No.

Field installable I/O card with 4 status inputs, 3 relay outputs, and 1 pusle output (KYZ)
I/O Extender module with 4 analog inputs and 4 analog outputs (4-20 mA)
I/O Extender module with 4 status inputs and 4 analog outputs (4-20 mA)
I/O Extender module with 8 status inputs
I/O Extender module with no pre-installed I/Oc

IOC44
IOX0044
IOX0404
IOX08
IOX

Ethernet Communications Card; 100 Mb Fiber or 10/100 Mb UTP Ethernet port and 1 RS-485 master port
Current/Voltage module
Current/Voltage module with high speed transient detection
4-line x 20-character Liquid Crystal Display with backlighting
4-line x 20-character Vacuum Fluorescent Display with I/R port and Proximity Sensor

ECC21
CVM
CVMT
CMD-LC
CMD-VF

I/R communications interface for the Vacuum Fluorescent Display


4 foot display cable
12 foot display cable
30 foot display cable

OCI-VF
CAB4
CAB12
CAB30

Priceq

q Contact your nearest Square D/Schneider Electric sales office.


c Contact your nearest Square D/Schneider Electric sales office for user-specified I/O options.

4-6

2000 Square D
All Rights Reserved

PL1

Discount
Schedule

3/00

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


Trip Systems and Protective Relays
Class 3010, 3030
POWERLOGIC Trip Unit for Low-Voltage Power Circuit Breakers
k Includes all protection features of the standard Digitrip series
k True RMS sensing
k Local readout of metering and diagnostics
k Remote monitoring via data communications at baud rates up to 19,200 bps:
RMS currents, per-phase and ground
Demand power and energy
Breaker status (open/closed/tripped)
Cause of trip (type, fault magnitude)
Protective settings and historical information
k Integral to breaker - no external current or potential transformers required
Digitrip RMS 810D

k POWERLOGIC System compatibility


k Retrofit options available
The POWERLOGIC trip unit for low-voltage power breakers integrates overcurrent protection, power metering and data
communications into a single, compact unit. Featuring true RMS sensing, the trip unit utilizes the breakers current
sensors and integral potential transformer module, simplifying installation and maintenance. POWERLOGIC application
software is available to organize information in a variety of useful formats, and remote control is possible using
programmable controllers or computers.
Contact your nearest Square D/Schneider Electric sales office for prices.
POWERLOGIC Digital Relay
k Three-phase (ANSI 50/51) and ground (50/51N or 50/51G) overcurrent protection
k User-selectable time-current curves
k Local keypad and display of metering and diagnostics

POWERLOGIC
Digital Relay

k Remote monitoring via data communications at baud rates up to 19,200 bps:


RMS currents, per-phase and ground
Demand currents, per-phase
Breaker status
Cause of trip (type, fault magnitude)
k POWERLOGIC System compatibility
k 120 Vac or 48/125 Vdc control power options
The POWERLOGIC Digital Relay accepts current inputs from standard 5-Ampere current transformers and is suitable
for a wide range of applications on medium-voltage circuits. Remote breaker operation is possible using programmable
controllers or computers.
Description

Price

DR LX S01 X0A TEN

$2624.

Digital Overcurrent Protective Relay


(Three-Phase and Ground) 48/125 Vdc control power

DR LX S01 X0A TBN

2624.

Digital Overcurrent Protective Relay (Three-Phase and Ground) with data communications,
120 Vac control power

DR LX S01 S0A TEN

3279.

Digital Overcurrent Protective Relay (Three-Phase and Ground) with data communications,
48/125 Vdc control power

DR LX S01 S0A TBN

3279.

CSH 30 core balance CT ground fault sensor

CSH 30

117.

CSH 120 core balance CT ground fault sensor

CSH 120

254.

CSH 200 core balance CT ground fault sensor

CSH 200

419.

Rear Cover for Digital Relay

AMT813

207.

Catalog No.

Digital Overcurrent Protective Relay


(Three-Phase and Ground) 120 Vac control power

POWER MONITORING AND


CONTROL

Class 3030 Protective Relays

POWERLOGIC is a Registered Trademark of Square D Company or related companies.


Windows is a Trademark of Microsoft Corporation.

3/00

PL1

Discount
Schedule

2000 Square D
All Rights Reserved

4-7

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


Application Software
Class 3080
Powerful Software Solutions
POWERLOGIC Power Monitoring and Control Systems provide a total,
integrated system approach to power management. Circuit monitors
and Power Meters provide a tremendous amount of data.
POWERLOGIC Application Software turns that data into powerful,
useful power monitoring information.
Power Information Anytime, Anywhere
k Microsoft Windows NT/Windows 98 software packages
k Easy-to-usedesigned with power system engineer in mind
k Flexible architecture, from stand-alone PC to client/server
k Real-time viewing with customization
k Data sharing with ODBC database and client/server DDE over
network as well as Active X/DCOM optional custom solutions

Customization

Shares SMS Data through DDE on Client

NT/98

The client application displays information collected by a


POWERLOGIC network server. The client application must be
used with either SMS-3000, SMS-1500, or PMX-1500.
Note: Must be on same PC when used with SMS-1500,
PMX-1500 or SMS-121

SMS1500

NT/98

Stand-alone POWERLOGIC power monitoring application


which communicates to devices and displays information
collected on the same PC. GFX is optional but must be located x
on the same PC. No support for additional clients.

Power Monitoring
Stand-alone EXPlorer
Stand-alone

PMX1500

NT/98

Stand-alone POWERLOGIC power monitoring application


which communicates to devices and displays information
x
collected on the same PC. GFX is optional but must be located
on the same PC. No support for additional clients.

System Manager
One-to-One
Stand-alone

SMS121

NT/98

Stand-alone POWERLOGIC monitoring application which


communicates to one device route only, any device type, any
x
supported communication method. GFX is optional but must be
located in the same PC. No support for additional clients.

Add-On

NT/98

Interactive
Graphics
Client

GFX1000

System Manager
Stand-alone

Create Graphical Drawings

Reports

SMS1000

Manual Control

The client application displays information collected by a


POWERLOGIC network server. The client application must be
used with SMS-3000.

System Manager
Client

Includes POWERLOGIC network server and one SMS client.


The POWERLOGIC network server must be located on the PC
that is connected to the device network for polling and then
x
serving the data to client applications over the distributed PC
LAN or on the same PC.c

Trending

PL Server

Waveform Capture

Alarm

Logging

Bar Charts

NT

Meter Panels

SMS3000

Real-Time Tables

System Manager
NT Client/Server

Description

Supports GFX

Windows
Platform

Set-up Devices and Routing

Catalog
Number

Supports Network Clients

Automatic Tasks

Reads DDE Data from other Applications

Client/Ser.

Class 3080
Product Name

Communicate to Single Devices

Monitor Multiple Device Types

Application Software Feature Comparison

Communicate to Multiple Devices

Real-Time Displays
System Manager software offers a variety of predefined and
customizable real-time data displays.

PL Client

New Features Available in System Manager Version 3.1


k Advanced waveform display and harmonic capabilities, including:
Harmonic data spectral plot through the 63rd harmonic for quick
analysis of circuit harmonics
Waveform capture overlays to easily compare phase
relationships
Zooming control and selection of waveform sections for in depth
analysis
k Virtual circuit node feature allows you to report and record sums,
differences or percentages of real-time monitored values.
Combine data from multiple devices.
Provides accurate cost allocation for departments and facilities.
Help avoid peak demands when there are multiple mains without
a summation meter

k Modbus protocol support


Open communications allowing compatibility with Modbus
speaking devices
k Enhanced compatibility with other software applications
k Support non-electrical utility monitoring, such as gas, water, and
steam, with proper scaling and units
k Tri-lingual language support

POWER MONITORING AND


CONTROL

c Number of connected clients is dependent upon Windows NT version purchased. NT Workstation allows 10 clients. NT Server allows unlimited clients. DDE is counted as a connected client.

POWERLOGIC is a Registered Trademark of Square D Company or related companies.


System Manager is a Trademark of Square D Company or related companies.
NT/Windows is a Trademark of Microsoft Corporation.

4-8

2000 Square D
All Rights Reserved

3/00

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


Application Software
Class 3080
POWERLOGIC Application Software
Description s

Disturbance Monitoring
Capture waveforms to analyze power disturbances.

Catalog Number

Price

System Manager Client/Server, Windows NT


System Manager Client, Windows NT/98
Interactive Graphics Client, Windows NT/98
System Manager Standalone, Windows NT/98
Power Monitoring EXPlorer, Windows NT/98
System Manager One-to-One, Windows NT/98

SMS3000q
SMS1000c
GFX1000j
SMS1500q
PMX1500q
SMS121q

t
t
$ 3600.
t
4500.
1850.

POWERLOGIC Ethernet Driver for SMS-3000 Software Family

TCPMMS

q
c
j
t
q

950.

Requires RS232/RS485 converter or Ethernet Comms. Card.


Requires 3080 SMS3000.
Requires 3080 SMS3000 or SMS1500 or PMX1500 or SMS121.
Contact your nearest Square D/Schneider Electric sales office for pricing.
Network card required only for remote client applications and Ethernet communication to device network.

Minimum System Requirements


The Square D POWERLOGIC application software requires a computer system with
certain minimum requirements (see table below). For your convenience, Square D also
offers complete computer systems which include all hardware and software required to
meet your operating needs. Please refer to POWERLOGIC Workstations on page 4-12.
The table below lists the minimum system requirements. The hard disk requirements for
Windows, other software, and logging, memory should also be considered when
choosing a computer.
Note: Users can select any number of quantities to log. Therefore, the hard disk space
required is dependent upon the number of quantities logged.
Windows NT/98
SMS-3000a
PMX-1500
SMS-1500
SMS-121

SMS-3000
PMX-1500
SMS-1500
SMS-121

Windows NTf
Windows 98

Windows NTf
Windows 98

VGA
(Super VGA recommended)

VGA
(Super VGA recommended)

Model

Pentium

486/66
(Pentium recommended)

RAM

64M
(128M recommended)

64M
(128M recommended)

Hard Disk

500Mp

500Mp

Program Size

50M c

50M c

SY/LINK Card

optional

...

RS-232 Port

required

...

Operating System

Interactive Graphics (GFX-1000)


Display system-wide information on drawings such as
one-line diagrams, front elevations, or site plans.

Display Mode

Network Card
Modem
Sound Card

14.4 or 28.8 (optional)

...

optional

optional

3.5" Drive

CD Drive

recommended

recommended

a SMS-3000 operates on Windows NT only.


f Windows NT, version 4.0 or higher, required in SMS-3000. The other applications run on Windows NT 4.0 or
Windows 98.
p This figure takes into account only what SMS will use. Any additional applications must be considered separately.
The amount of space taken up by SMS on the hard disk depends on whether logging data is stored on the same
computer.
c SMS uses about 8M; the additional is due to system components.
t Required in SMS-3000, to support network clients; optional in other products.
u Required unless CD drive is available.

For additional functionality, a Billing Module, SQL Database Module and Pager Module
are also available. Please contact your nearest Square D/Schneider Electric sales office
for pricing.

POWER MONITORING AND


CONTROL

Additional Software Options

POWERLOGIC and SY/LINK are Registered Trademarks of Square D Company or related companies.
Windows is a Trademark of Microsoft Corporation.

3/00

PL1

Discount
Schedule

2000 Square D
All Rights Reserved

4-9

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


System Components and Packaged Systems
Class 3020, 3050, 3070
POWERLOGIC Ethernet Gateway
The POWERLOGIC Ethernet Gateway provides a direct connection to Ethernet-TCP/IP
networks to make power monitoring and power quality information available over new and
existing local and wide area networks. Electrical distribution systems can be better
managed using Ethernet technologies and the Internet.
Class 3050 POWERLOGIC Ethernet Gateway
Description
POWERLOGIC Ethernet Gateway1 port
POWERLOGIC Ethernet Gateway2 ports

Ethernet Gateway

Type

Price

EGW1

$2385.

EGW2

4028.

POWERLOGIC Ethernet Gateway Mounting Brackets

EGWMBK

133.

POWERLOGIC Ethernet Gateway Null Modem Cable

EGWNMCl

37.

l One required per job for setup.

POWERLOGIC Ethernet Communication Modules


The POWERLOGIC Ethernet Communication Module (ECM) connects POWERLOGIC
and Modbus/Jbus devices to an industry-standard Ethernet network. The ECM receives,
converts, and transmits data over Ethernet using Modbus TCP/IP protocol to your PC
where the information can be monitored and analyzed with POWERLOGIC System
Manager (SMS) software
Class 3020 POWERLOGIC Ethernet Communication Modules
Catalog No.

Price

POWERLOGIC ECM for direct mounting to the back of a Series 2000


circuit monitor and without I/O module

Description

ECM2000

$1825.

POWERLOGIC ECM for remote mounting when circuit monitor is not


present or circuit monitor has on-board I/O module

ECMRM

1875.

POWERLOGIC Interface for MICROLOGIC Circuit Breakers

Ethernet Communication Modules

This interface collects and makes per-phase RMS and ground fault currents, circuit
breaker data and trip setting and historical trip data available to the POWERLOGIC
system. A single interface supports up to 8 circuit breakers.
Class 3050 POWERLOGIC Product Interfaces
Description
Product Interface for MICROLOGIC Circuit Breakersq

Catalog No.

Price

PIF3

$2611.

q Requires 1 CIM3F Communications Adapter per Circuit Breaker.

POWERLOGIC Packaged Systems


POWERLOGIC is a flexible modular system. An easy way to start building a system is
with a Quick Start Kit. These kits contain everything needed to start monitoring power.
They include a Circuit Monitor, application software, and a communications cable.
Class 3070 Quick Start Kits
Description
Quick Start Kit including CM2350, SMS-121 software and OCI
(3090 OCI2000)

Catalog No.

Price

QSK2350

$4965.

POWER MONITORING AND


CONTROL

Product Interface for


MICROLOGIC Circuit Breakers

MICROLOGIC and POWERLOGIC are Registered Trademarks of Square D Company or related companies.

4-10

2000 Square D
All Rights Reserved

PL1

Discount
Schedule

3/00

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


Engineering Services
Class 3000
Power System Studies
The Square D Power System Analysis Group provides expertise in a variety of electrical power system studies. These
studies can improve the reliability, safety and efficiency of all types of electrical systems, leading to long-term cost
savings. For example, a harmonic analysis identifies equipment exposed to destructive harmonics, and provides
solutions to increase product life and avoid damage or failure. System studies can provide economic benefits for small
and large electrical systems, whether new or existing. Some of the more common system studies include:
k Short-Circuit Analysis
k Time-Current Coordination
k Motor Starting / Voltage Drop
k Motor Starting / Torque-Speed Acceleration Analysis
k Safe Motor Re-energization
k Harmonic Analysis
k Transient Analysis
k Power Factor Correction Analysis
k Other System Specific Analysis
For additional information and pricing, contact your nearest Square D/Schneider Electric sales office or write to:
Square D Company, 2365 Harrodsburg Road, Suite B410, Lexington, KY 40504.
Current in Amperes
1000
500

PU-1

FLA

200
100

3-SE Main
10-NE FDR
2-CS3 Fuse

50

T1-ANSI
20

Time in Seconds

IG-GRD RLY
1-UTIL RLY

10
5

2
1
.5

PMCS Technical Support


There are several ways to receive top quality support
on POWERLOGIC and POWERLINK products:
k Phone 615-287-3400

.2

TX INRUSH
X

.1

k Fax 615-287-3403
k Email: pmosuprt@squared.com

.05

k D-Fax 800-557-4556 (PM&CS Index is


Document #104)

.02
.01
.5

10

20

50

100 200

500 1000 2000

5000 10000

Time-Current Coordination Studies are just one of the many


power system studies Square D can provide.

POWERLOGIC University
POWERLOGIC University offers a number of courses covering POWERLOGIC and POWERLINK products. Training is
conducted at the product headquarters, providing an opportunity to meet product developers.
POWERLOGIC University
Catalog Number

Price
q

POWERLOGIC Fundamentals (Self Study Course)

PLUC120CR

POWERLINK Fundamentals

PLUC110

POWERLOGIC System Installation & Maintenance Certification

PLUC100

Comprehensive POWERLOGIC System

PLUC200

Comprehensive POWERLOGIC Bundle (2 Courses)

PLUC205

SMS-3000 Administrator Certification

PLUC300

Energy Management and Advanced Reporting

PLUC230

Power Quality with POWERLOGIC Systems

PLUC140

Customer Site Training

PLUCSite

POWERLOGIC Technical Support CD

PLUCD

POWERLOGIC/POWERLINK Priority Technical Support

PSUP100

PLUC210

POWER MONITORING AND


CONTROL

Description
POWERLOGIC Update Course

q Contact your nearest Square D/Schneider Electric sales office for schedules, course descriptions, and pricing.

POWERLINK, POWERLOGIC, MICROLOGIC and SY/LINK are Registered Trademarks of Square D Company or related companies.

3/00

PL1

Discount
Schedule

2000 Square D
All Rights Reserved

4-11

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

POWERLOGIC Power Monitoring and Control Systems


Power Management Services
Class 3000
Power Monitoring and Control Systems
Power System Integration

Power Management Services provides a complete range of design and operational


services including specifying, developing, installing, commissioning, supporting, and
training users of power monitoring and control systems and remote power switching
systems. Engineers maintain expertise in many areas such as communications, personal
computers, protective relaying, automatic control systems, and programmable
controllers.
k System Design and Bill of Material Recommendations
k Remote Power Switching System Design
k Develop Specifications, Drawings, Documentation
k Automatic Control Systems/PLC Ladder Programming, including Load Shed/Peak
Shaving Schemes
k Custom Hardware/Software Solutions
k Third Party Communications Interfaces
k Configured Workstations, User Software Interfaces
k On-Site Installation Assistance, Component Configuration & Startup
k Metering Connection Verification/Testing
k On-Site and Headquarters-based Customer Training
k Troubleshooting Assistance, Support for Hardware and Software Products
k Product Upgrades

Application Engineering can provide


the total system solution

k Project Coordination
k Power Monitoring Web Server Systems

POWERLOGIC Workstations
Square D offers a complete systems approach to power
monitoring. POWERLOGIC Application and Engineering
provides POWERLOGIC Workstations tested and
approved personal computers completely configured
based on the individual system requirements.
POWERLOGIC Workstations are designed to handle
large amounts of system information, and provide it to
those who need it, when they need it. Workstations placed
in key locations allow plant engineers, operators,
maintenance personnel, and others to make informed
decisions using real-time and historical information.
Ordering Information
POWERLOGIC Workstations should be ordered by
description by specifying the following: PC hardware
(POWERLOGIC can make recommendations if desired),
optional equipment such as modems, printers, etc., and
software to be installed and configured.

Application Engineering
Catalog
Number

Price

Engineering Services
System Engineering and Project Coordination

...

Custom POWERLOGIC Engineering Services Hardware


Personal Computer Workstations, Panels, Enclosures, Interfaces

...

Custom POWERLOGIC Engineering Services Software


Ladder Logic Programming, Graphics, Reports, Macros

...

System Startup - On-site Commissioning

...

PowerLink AS Control Module Programming

...

Power Quality/Energy Management Engineering Studies

...

Portable Circuit Monitor


Includes 1 CM2452 Circuit Monitor, VT and CT test leads, communications
cables, canvas bag for leads, instruction bulletin

...

Portable Circuit Monitor with built-in 19.2k baud modem,


or input/ouput module, or both

...

Power Management Remote Monitoring Services

...

Description

Power Quality/Energy Management

q Contact your nearest Square D/Schneider Electric sales office.

Contact your nearest Square D/Schneider Electric sales


office for pricing.
PMCS Technical Support

k Phone 615-287-3400
k Fax 615-287-3403
k Email: pmosuprt@squared.com
k D-Fax 800-557-4556 (PM&CS Index is
Document #104)

POWER MONITORING AND


CONTROL

There are several ways to receive top quality support


on POWERLOGIC and POWERLINK products:

4-12

2000 Square D
All Rights Reserved

PL1

Discount
Schedule

3/00

Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com

Você também pode gostar