Você está na página 1de 3

FT 4422

RESET E#5
M may , gat DIP Switch 101-1 tren MainBoard t Off --> On --> Off , tat roi
m cong tac chnh .

U-CODE CONDITIONS
U1 - RIGHT COVER OPEN
Possible Cause
The right cover stays open Right cover switch failure
Main board defective

U2 - KEY COUNTER NOT SET


Possible Cause
The key counter is not set properly Key counter connector defective
Main board defective

U4 - SORTER OPEN
Possible Cause
The sorter stays open Sorter switch failure Main board defective

U6 - DRUM PROTECTION SHEET REMAINING


Possible Cause
The drum protection sheet remains on the drum. ID sensor failure
Main board defective

SERVICE CALL CONDITIONS


CODE #11 EXPOSURE LAMP ERROR
Definition
The feedback signal becomes higher than 4.2 volts (r.m.s.) for 1.0
second when the exposure lamp is on.
The feedback signal becomes higher than 0.5 volt (r.m.s.) for 1.0 second
when the exposure lamp is off.
Possible Causes
Exposure lamp open Thermofuse open
Power Supply/AC Drive Board Defective
Main board defective DC harness defective

CODE #12 EXPOSURE LAMP ERROR


Definition
The feedback signal falls below 0.5 volts (r.m.s.) for 1.0 second when the
exposure lamp is on.
The exposure stays on for longer than 15 seconds.
Possible Causes
AC drive board defective Main board defective

CODE #13 ZERO CROSS SIGNAL ERROR


Definition
The CPU does not receive the zero cross signal within 3.0 seconds.
Possible Causes
Main board defective Power supply/ac drive board defective
Zero cross line open
CN404 on power the supply/ac drive board, or CN114 on the main board
is not correctly connected.
1

FT 4422

CODE #21 SCANNER HOME POSITION ERROR


Definition
The scanner home position sensors output remains LOW (de-actuated)
for 12 seconds after the main switch is turned on.
Possible Causes
Scanner home position sensor failure Scanner motor defective
Main board defective Power supply/ac drive board defective
Incorrect scanner drive wire position
CN402 or CN403 on the power supply/ac drive board, or CN114 on the
main board is not correctly connected.

CODE #22 SCANNER HOME POSITION ERROR


Definition
The scanner home position sensors output remains HIGH (actuated) for
1.0 second after the scanner starts.
Possible Causes
Scanner home position sensor failure Scanner motor defective
Main board defective Power supply/ac drive board defective
Defective dc harness Incorrect scanner drive wire position
CN402 or CN403 on the power supply/ac drive board, or CN120 or
CN114 on the main board is not correctly connected.

CODE #28 LENS HOME POSITION ERROR


Definition
The lens home position sensors output remains LOW (de-actuated) for
3.5 seconds after the lens moves to the home position.
Possible Causes
Lens home position sensor failure Lens drive motor defective
Main board defective Lens drive mechanism defective
CN120 on the main board is not correctly connected.

CODE #29 LENS HOME POSITION ERROR


Definition
The lens home position sensors output remains HIGH (actuated) for 3.5
seconds after the lens leaves the home position.
Possible Causes
Lens home position sensor failure Lens drive motor defective
Main board defective Defective dc harness
Lens drive mechanism defective
CN120 on the main board is not correctly connected.

CODE #2A 4TH/5TH MIRROR HOME POSITION ERROR


Definition
The 4th/5th mirror home position sensors output remains HIGH (actuated)
for 2.5 seconds after the 4th/5th mirror assembly leaves the home
position.
Possible Causes
4th/5th mirror home position sensor failure
4th/5th mirror motor defective Main board defective
4th/5th mirror drive mechanism defective Defective dc harness
CN123 on the main board is not correctly connected.

CODE #2B 4TH/5TH MIRROR HOME POSITION ERROR


Definition
2

FT 4422
The 4th/5th mirror home position sensors output remains LOW (deactuated) for 2.5 seconds after the 4th/5th mirror assembly moves to the
home position.
Possible Causes
4th/5th mirror home position sensor failure
4th/5th mirror motor defective Main board defective
4th/5th mirror drive mechanism defective
CN123 on the main board is not correctly connected.

CODE #52 FUSING LAMP WARM-UP ERROR


Definition
The temperature detected by the thermistor does not reach 175C within
100 seconds after the main switch is turned on.
Possible Causes
Thermistor position error Fusing lamp open Thermofuse open
Power supply/ac drive board defective Main board defective
Defective ac harness
T407 or T408 on the ac drive board is not correctly connected.

CODE #53 FUSING LAMP OVERHEAT


Definition
The thermistor detects a temperature higher than 230C for 3 seconds.
Possible Causes
Thermistor short Power supply/ac drive board defective
Main board defective Fusing harness shorted

CODE #55 FUSING THERMISTOR OPEN


Definition
The temperature detected by the thermistor does not detect 2C within 30
seconds after the main switch is turned on.
Possible Causes
Thermistor open Main board defective
Power supply/ac drive board defective
Fusing lamp open Thermofuse open Defective ac harness
T407 or T408 on the ac drive board is not correctly connected.

E70 (IN THE MAGNIFICATION INDICATOR) TONER


OVERFLOW RESET SP# 83
Definition
The toner overflow counter has reached the number specified by SP116.
The toner overflow sensor turns on (if the optional toner overflow sensor is
installed).
Possible Causes
Toner overflow Main board defective
Defective toner overflow sensor (if installed)