Escolar Documentos
Profissional Documentos
Cultura Documentos
GAS DETECTION:
SPECIALTY
www.conceptcontrols.com
83
Gas
Range
0-19.99 ppm
Bromine
0-1999 ppb
CO
0-1999 ppm
4140-1999m
Carbon Monoxide
0-500.0 ppm
4140-500.0m
0-199.9 ppm
4140-199.9m
0-1999 ppb
ClO2
0-19.99 ppm
Chlorine Dioxide
0-1000 ppb
MODEL No.
4700-19.99m
4700-1999b
4540-199.9m
0-19.99 ppm
4540-19.99m
0-199.9 ppm
4150-199.9m
Nitrogen Dioxide
0-19.99 ppm
4150-19.99m
0-19.99 ppm
Ozone
0-1999 ppb
PrO
0-199.9 ppm
4320-199.9m
Propylene Oxide
0-19.99 ppm
4320-19.99m
4480-19.99m
4480-1999b
4320-1999b
SO2
0-19.99 ppm
Sulfur Dioxide
0-50.0 ppm
4240-50.0m
0-1999 ppb
4240-1999b
4240-19.99m
H2NNH2
0-0.5/0-2 ppm
4183UL
CH3NHNH2
0-2/0-10 ppm
4186UL
(CH3)2NNH2
0-100/0-2000 ppb
4187UL
Hydrazine
0-100/0-1000 ppb
4189UL
NO2
0-2/0-10 ppm
4152UL
Nitrogen Dioxide
0-10/0-50 ppm
4154UL
Ethylene
0-199.9 ppm
4070-199.9m
0-19.99 ppm
4070-19.99m
0-500.0 ppm
470-500.0m
0-1999 ppb
4070-1999b
EtO
0-19.99 ppm
Ethylene Oxide
0-50.0 ppm
4200-19.99m
4200-50.0m
0-1000 ppb
4200-1000b
0-1999 ppb
4200-1999b
4160-5.00m
4160-19.99m
0-1000 ppb
4160-1000b
0-1999 ppb
4160-1999b
H2NNH2
0-1000 ppb
4180-1000b
CH3NHNH2
0-1999 ppb
4180-1999b
(CH3)2NNH2
84
4150-1999b
O3
4330-1000b
4330-1999b
HBr
0-19.99 ppm
Hydrogen Bromide
0-1999 ppb
HCl
0-19.99 ppm
Hydrogen Chloride
0-1999 ppb
HCN
0-19.99 ppm
4280-19.99m
Hydrogen Cyanide
0-199.9 ppm
4280-199.9m
0-1999 ppb
4540-1999b
NO2
4340-1999b
4070-1999m
0-19.99 ppm
0-199.9 ppm
4330-19.99m
0-1999 ppm
Formaldehyde
4170-500b
4170-1999b
Nitric Oxide
4340-5.00m
C2H4
0-5.00 ppm
4170-1000b
NO
4340-19.99m
0-1999 ppb
HCHO
0-1999 ppb
4170-19.99m
UL Listed Models
Br2
0-19.99 ppm
0-500 ppb
0-1999 ppb
Ordering Information
Chlorine
0-1000ppb
0-1999 ppb
0-5.00ppm
0-19.99 ppm
Hydrogen Sulfide
0-1999 ppb
Features:
3-1/2 digit LCD display
58 sensor options
Integral sample pump & plug-in
charger
User-adjustable single alarm
level activating audible and visual
alarm
0-100 mV output
Carrying case with shoulder strap
12 inch (30.5 cm) Teflon sample
probe
Cl2
H2S
4800-19.99m
4800-1999b
4360-19.99m
4360-1999b
4280-1999b
www.conceptcontrols.com
Typical Minimum Detection of Commonly Requested Single Gases: 300 Metre Path:
Compound
Acetaldehyde
Acetic Acid, monomer
Acetone
Acetonotrile
Acetl Chloride
Acetylene
Acrolein
Acrylic Acid
Acrylonitrile
Ammonia
Aniline
Arsine
Benzene
Bis-dichloroethylether
Boron Trichloride
Bromomethane
Butadiene
n-Butane
2-Butanone
Carbon Dioxide
Carbon Disulfide
Carbon Monoxide
Carbon Tetrachloride
Carbon Tetrafluoride
Carbonyl Sulfide
Chlorobenzene
Chlorodifluoromethane
Crotonaldehyde
Chloroethane
Chloroform
Chloromethane
Chlorotrifluoromethane
Cyclohexane
Cyclohexene
Cyclopentene
Cyclopropane
1,2 Dibromoethane
m-Dichlorobenzene
o-Dichlorobenzene
Dichlorodifluoromethane
1,1 Dichloroethane
1,2 Dichloroethane
1,1 Dichloroethene
1,2 Dichloroethene
PPB
2
4.7
9.7
43.3
2.2
2.6
2.8
1.5
5
0.7
13
5.7
110
2.3
0.7
27.3
3.1
7
7
43.7
11.3
4.3
0.8
0.7
1.6
5
0.7
2.5
6.7
0.8
31.3
2
0.7
2.4
4.3
6.7
7.7
4
3.1
0.7
3.7
24.3
2.3
6.7
Compound
Dichloromethane
1,2 Dichlorotetrafluorethane
Diethyl Ether
Dimethylamine
Dimethyl Ether
1,1 Dimethyl Hydrazine
Dimethyl Sulfide
Ethane
Ethanol
Ethyl Benzene
Ethylene
Ethylene Oxide
Ethyl Vinyl Ether
Fluorobenzene
Formaldehyde
Formic Acid, Monomer
Furan
n-Hexane
Hydrogen Bromide
Hydrogen Chloride
Hydrogen Cyanide
Hydrogen Fluoride
Hydrogen Sulfide
Isobutane
Isobutanol
Isobutylene
Isoctane
Isoprene
Isopropanol
Mesitylene
Methane
Methanol
Methyl Acetate
Methyl Acrylate
Methylamine
2-Methyl 2-Butene
3-Methyl 1-Butene
Methyl Formate
Methyl Methacrylate
Methyl Nitrite
2-Methyl Pentane
3-Methyl Pentane
2-Methyl 1-Pentene
2-Methyl 2-Pentene
PPB
4.3
0.7
0.9
2.4
3
1.2
1
5.3
3
11.3
2.1
3.7
4
5.7
1.5
2.6
3.7
1.5
4
2
22.7
0.7
1500
2.5
1.1
1.4
2
1.5
3.7
3.1
11.7
1.4
2.7
2.2
9.7
15.7
5.3
5
2.2
2.2
3.7
2
5.7
3
www.conceptcontrols.com
Compound
4-Methyl 2-Pentene
Methyl Vinyl Ether
Methyl Vinyl Ketone
Nitric Acid
Nitric Acid
Nitro Benzene
Nitro Ethane
Nitrogen Dioxide
Nitro Methane
Nitrous Acid
Nitrous Oxide
Octane
Ozone
n-Pentane
1-Pentene
2-Pentene
trans-3-Pentene nitrile
Phosgene
Phosphine
Propane
Propionaldehyde
Propionic Acid
Propylene
Propylene Oxide
Silicon Tetrafluoride
Styrene
Sulfur Dioxide
Sulfur Hexafluoride
1,1,1,2 Tetrachloroethane
1,1,1,2 Tetrachloroethane
Tetrachloroethene
Tetrahydrothiophene
Toluene
1,1,1 Trichloroethane
1,1,2 Trichloroethane
Trichloroethene
Trichlorofluormethane
Trochlorotrifluoroethane
Vinyl Acetate
Vinyl Chloride
Vinylidene Chloride
m-Xylene
o-Xylene
p-Xylene
PPB
4
4.7
6.3
2.1
76.7
4.3
10
9.7
27
0.7
6.3
0.8
2.2
2.8
3.3
5
2
0.7
9
6.3
1.6
7.3
4.7
7.3
0.7
4
15
0.7
1.3
133.3
0.7
3
11.3
1.8
4.7
0.8
0.7
0.7
2.5
5.3
2.3
5
9
4.7
85
Mini
MX / BX
(Xenon
Source)
MD / BD
(Deuterium
Source)
Acetaldehyde (C2H4O)
Acetone (CH3COCH3)
Acrolein (C3H4O)
Ammonia (NH3)
Benzene (C6H6)
Formaldehyde (CH2O)
Mercury (Hg)
Naphthalene (C10H8)
Oxygen (O2)
Ozone (O3)
86
Phenol (C6H5OH)
Styrene (C8H8)
Toluene (C6H5CH3)
Trimethylbenzene (C9H12)
Mini Sentry
Cerex Mini Sentry Continuous
Analyzers are engineered specifically
for low cost, low maintenance,
high performance point monitoring
arrays or optional short, open path
monitoring arrays. Stock models are
available for ammonia, benzene and
chlorine monitoring.
A direct replacement for electrochemical, PID and NDIR sensor
arrays, the Mini Sentry cannot be poisoned, is unaffected by
high humidity, offers ppb level detection limits, and is easily
installed for long term monitoring installations.
www.conceptcontrols.com
3000,
3000P,
3000F
Acetaldehyde (C2H4O)
Acetone (CH3COCH3)
Acrolein (C3H4O)
3000XF
3000C
Ammonia (NH3)
Benzene (C6H6)
Chlorine (Cl2)
Formaldehyde (CH2O)
Isoprene (C5H8)
Mercury (Hg)
Naphthalene (C10H8)
NitrogenOxide(NO)
Oxygen (O2)
Ozone (O3)
Phenol (C6H5OH)
Styrene (C8H8)
Toluene (C6H5CH3)
Trimethylbenzene (C9H12)
www.conceptcontrols.com
87
FT 5000
& 5000P
FT 5000+
Acetaldehyde (C2H4O)
Acetone (CH3COCH3)
Acetylene (C2H2)
Acrolein (C3H4O)
Ammonia (NH3)
Benzaldehyde (C7H6O)
Benzene (C6H6)
Butane (C4H10)
n-Butyl (C6H12O2)
Chlorine (Cl2)
Ethane (C2H6)
Ethanol (C2H6O)
Formaldehyde (CH2O)
n-Hexane (C6H14)
Isoprene (C5H8)
Mercury (Hg)
Methane (CH4)
Napthalene (C10H8)
Oxygen (O2)
Phenol (C6H5OH)
Phosgene (CCl2O)
Styrene (C8H8)
Toluene (C6H5CH3)
Trimethylbenzene (C9H12)
Water Vapor (H2O)
88
FT5000+
FT5000 P
www.conceptcontrols.com
AreaRAE
RENTAL
RKI Eagle 2
NEW
RENTAL
RENTAL
WIRELESS
www.conceptcontrols.com
89
ChemKeyTM TLV
Detectable Gases
Chemcassette
The Chemcassette detection system is the heart of an MDA
toxic gas monitoring system. Chemcassettes use a dry reagent
medium to collect and analyze air to detect gas leaks. When the
Chemcassette is exposed to a target gas, it changes colour in
direct proportion to the concentration of gas present.
Range
Amines
Ammonia (NH3)*
2.6-75.0ppm
Ammonia (NH3)-II
2.6-75.0ppm
3-60ppb
0.4-12.0ppm
2-60ppb
4-60ppb
Trimethylamine (TMA)
Diisocyanates
CHDI, HDI, HMDI, IEM, IPDI, MDI, NDI,
PPDI, TDI, TMDI, TMXDI, XDI
1.1-30.0ppm
Range
2-60ppb
Hydrazines
MMH*
21-600ppb
N2H4
20-300ppb
UDMH*
53-1500ppb
Hydrides
Arsine (AsH3)
15-150ppb
Diborane (B2H6)
31-300ppb
Disilane (Si2H6)
1.5-15ppm
Germane (GeH4)
141-600ppb
20-150ppb
Phosphine (PH3)
32-900ppb
Silane (SiH4)
0.5-15ppm
Stibine (SbH3)
20-300ppb
tert-Butylarsine (TBA)
15-150ppb
tert-Butylphosphine (TBP)
60-900ppb
1.1-30.0ppm
1.1-30.0ppm
Low Level
1-90ppb
Mineral Acids
SPM
0.3-9.0ppm
0.5-15.0ppm
0.6-9.0ppm
0.2-6.0ppm
26-750ppb
Oxidizers
Bromine (Br2)
11-300ppb
Chlorine (Cl2)*
0.1-3.0ppm
Chlorine (Cl2)-II
0.5-1.5ppm
0.1-3.0ppm
0.3-9.0ppm
Ozone (O3)
31-300ppb
Phosgene (CoCl2)
11-300ppb
90
11-300ppb
www.conceptcontrols.com
0.2-6.0ppm
NEW
RENTAL
CO2
O2
CO
H2S
CO2
0-25% (vol)
O2
0-100% (vol)
CO
0-2000ppm***
H2S
0-500ppm***
Features:
CO2 0 20%
Options for:
O2 0 100%
Dual temperature probes
32F 122F (0C 50C)
Data storage and download
Humidity sensor 0 100%
Gas Accuracy*
CH4
70-100% 1.5% FS
CO2
60-100% 1.5% FS
O2
CO
0-2000ppm 1.0% FS
H2S
0-500ppm 2.0% FS
Applications:
IVF
Research
Laboratories
Medical
Benefits:
Improved accuracy on CO2 readings
Quick verication of CO2 incubator
levels
Time saving with dual
temperature probes
Large data storage with
software
Easy to read, large, well-lit display
Built in gas moisture removal
Features:
CO2 0 100%
Options for:
O2 0 100%
Dual temperature probes
32F 122F (0C 50C)
Humidity Sensor 0 100%
Data storage and download
Ranges
CH4
www.conceptcontrols.com
Applications:
Food Processing
Research
Brewing
Medical
Benefits:
Improved accuracy on CO2
readings
Quick verication of CO2 levels
Time saving with dual
temperature probes
Large data storage with software
Easy to read large well-lit
display
Built in gas moisture removal
91
Applications:
General IAQ
Site Audits
Laboratories
Medical
Benefits:
Improved accuracy on CO2
readings
Quick verication of CO2 levels
for site audits
Time saving with dual
temperature probes
Large data storage with software
Easy to read, large, well-lit display
Built in gas moisture removal
92
Applications:
Operating Rooms
Dental Practices
Veterinary Clinics
X-ray Departments
Applications:
Hospital piped gases
Leak detection
Benefits:
4 gases measured in one
analyzer
Easy user calibration
Quick verification of gas quality
Enter specific site & IDs for
monitoring points
Identify contaminants CO and
CO2
Flame Ionization
Detectors
Thermo Scientific TVA-1000B
Portable FID/PID
The TVA-1000B is the only over the shoulder portable vapour
analyzer that offers both PID (Photoionization Detection) and
FID (Flame Ionization Detection). Users can measure a wide
variety of organic vapours over an impressive dynamic range
(0-50,000 ppm). The FID operates by breaking hydrogencarbon bonds and is not limited by the ionization potential of
the molecule.
Features:
Dual simultaneous FID/PID or
single FID detectors
Portable and
lightweight
Multiple response
factors and curves
Multi-point
calibration
Eight
programmable
location labels
On-board datalogging
www.conceptcontrols.com