TABLE OF CONTENT

CONTENT

PAGE

INTRODUCTION

DATA COLLECTION

2-5

DISCUSSION

6-8

CONCLUSION

APPENDIX

10

REFERENCES

11

INTRODUCTION

AIQ is defined as the physical and chemical nature of indoor air, as


delivered to the breathing zone of building occupants, which produces a
complete state of mental, physical and social wellbeing of the occupants,
and not merely the absence of disease or infirmity by the The World Health
Organization (WHO). The purpose of the AIQ cover or involves the collection
of air samples, monitoring human exposures to pollutants, collection of
samples on building surfaces, and computer modelling of air flow inside
buildings other than that it measure of the buildings interior air in terms of
the occupants potential health and comfort. Chemical, physical, and
biological contaminants can cause symptoms ranging from discomfort to
serious illness.
The task given to our group for the Indoor Air Quality subject was to
measure the physical, chemical and biological data in the place that had
been decide. The requirements for the place that need to be conduct
experiment or test must be more than 30 m2 @ 323 ft2. The place that been
decide is Residential house Lorong Harmoni at Parit Haji Salleh Ros where the
building orientation was facing north and near with the other residential
house and the layout for the internal was room layout based.

DATA COLLECTION

i.

Outdoor weather condition


The experiment was conduct at 28th March 2016 on Monday. The
weather condition at that time was sunny day, windy and the

ii.

Time:12.20 pm
Type of ventilation system
The ventilation used for the experiment building was by natural
ventilation from the windows that release the hot air and receive
the cold air besides, the mechanical ventilation also used in that

iii.

building like ceiling fan and theres no air conditional provided.


Types of Opening
The Opening that been used by that building was casement window,

iv.

owning and swing door.


Equipment used
The equipment used on that experiment just 4 in meter kit,
Measuring tape, and Yes Air that is to measuring the quantity of the
carbon dioxide.
Types of ducting
The ducting types that been use was Wind flow brick

v.

Indoor air quality measurement at sampling point


1) Physical
No.

Air

Relative

Air

Mean

Temperature
(oC)

Humidity
(%)

Velocity
(m/s)

Radian
Temperatu
re

1
2
3
4
5
6
Averag

33.8
34.2
34.2
34.3
34.3
34.3
34.2

51
53
48.9
40.7
51.5
46.9
48.7

0.0
0.0
0.0
0.0
0.0
0.9
0.15

e
2) Chemical
No.

CO2 ppm

1
2
3
4
5
6

3) Biological
Spider web

660
501
462
432
512
550

CO
-

VOC
-

TVOC

Formaldehy

de
-

Home dust

Fungi

vi.

Evidence of data collection

The data measurement was


collected by using the 4 in
meter kit for certain data.

The data measurement for


the CO2 was taken by using
the Yes Air Equipment.

DISCUSSION

Comparison with DOSH (Department of Occupational Safety


and Health or any relevant standard).
Measurement

Experiment data

DOSH Standard

66Air Temperature

34.2

23-26

(oC)
Relative Humidity (%)
Air Velocity (m/s)
CO2 (ppm)

48.7
0.15
519.5

40-70
0.15-0.50
C1000

Suggestion to improve air quality


Indoor air quality is very important to occupant in the building to
ensure the safe and good health of the occupants from any hazard that
may affect the health, comfort and productivity of building occupants.
So theres some suggestion on control measure to improve air quality
toward green. Firstly properly ventilate the homes, increase the
amount of fresh air by opening windows and doors or running air
conditioners and fan that exhaust to outside. Furthermore changing the
heating and air conditioner filters frequently and follow the
manufacture recommendation. Other than that, adjust the humidity
where the EPA recommends humidity level of between 30-50%. Too
much humidity could potentially lead to mole. Besides, theres other
step that can be taken like installation of air cleaning devices.

Any relevant discussion

CONCLUSION
In a conclusion, from the experiment that had been conducted we are
able to measure the physical, chemical and biological data of indoor air
quality by using the equipment that been provided. By the experiment
was conducted also we gained the knowledge about the indoor air
quality in the building and detect whether the indoor air quality was in
good condition or not by measuring the data and comparing toward
the standard. So the awareness about the indoor quality are more alert
toward us and we will find the solution to solve the problem of the
contaminant that been in our room or space. The effect of the
contaminant air gives the bad effects to our body life and it is long
term effect. But from the experiment the student are more concern
toward making the indoor air quality better and comfort.

APPENDIX

REFERENCES
1. https://www.epa.gov/indoor-air-quality-iaq/introductionindoor-air-quality
2. http://www.cpsc.gov/en/Safety-Education/SafetyGuides/Home/The-Inside-Story-A-Guide-to-Indoor-AirQuality/
3. https://en.wikipedia.org/wiki/Indoor_air_quality
4. http://www.appropedia.org/Indoor_air_pollution