Você está na página 1de 266

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.

D)

Product Description
Issue

03

Date

2013-01-15

HUAWEI TECHNOLOGIES CO., LTD.

Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address:

Huawei Industrial Base


Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website:

http://www.huawei.com

Email:

support@huawei.com

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

About This Document

About This Document


Overview
This document presents the exteriors and describes the functions, technical specifications,
application scenarios, structure, components, and cable connections of the APM30H (Ver.D),
TMC11H (Ver.D), IBBS200D (Ver.D), and IBBS200T (Ver.D). It also describes the
configurations, functions, and specifications of the modules and boards, and details such as cable
types, cable connections, and connector specifications.
l

APM30H is short for advanced power module with heat exchanger.

TMC11H is short for transmission cabinet of 11 U high with heat exchanger.

IBBS200D is short for integrated battery backup system with direct cooling.

IBBS200T is short for integrated battery backup system with thermal electric cooling.

Product Version
Product Name

Product Version

APM30H Ver.D (APM30H for short)

V300R003C00

TMC11H Ver.D (TMC11H for short)


IBBS200D Ver.D (IBBS200D for short)
IBBS200T Ver.D (IBBS200T for short)

Intended Audience
l

Base station installation personnel

System engineers

Site maintenance personnel

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

ii

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Contents

Contents
About This Document.....................................................................................................................ii
1 Changes in APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D) Product Description
..............................................................................................................................................................1
2 APM30H Cabinet...........................................................................................................................3
2.1 Cabinet Exterior..................................................................................................................................................4
2.2 Cabinet Engineering Specifications....................................................................................................................4
2.3 Engineering Specifications of Customer Equipment in APM or TMC Series Cabinets....................................8
2.4 Cabinet Application Scenarios.........................................................................................................................11
2.5 Cabinet Interior.................................................................................................................................................13
2.6 Components in an APM30H.............................................................................................................................15
2.6.1 EPU05A...................................................................................................................................................15
2.6.2 Junction Box............................................................................................................................................33
2.6.3 FAN 02D.................................................................................................................................................35
2.6.4 ELU.........................................................................................................................................................36
2.6.5 Door Status Sensor..................................................................................................................................41
2.6.6 Filler Module...........................................................................................................................................44
2.6.7 AC Heater................................................................................................................................................45
2.6.8 SOU.........................................................................................................................................................45
2.7 APM30H Cables...............................................................................................................................................47
2.7.1 Cable List.................................................................................................................................................47
2.7.2 Cable Connections...................................................................................................................................49
2.7.3 PGND Cable............................................................................................................................................52
2.7.4 Equipotential Cable.................................................................................................................................58
2.7.5 Power Cables...........................................................................................................................................63
2.7.6 Signal Cables...........................................................................................................................................75

3 TMC11H Cabinet.........................................................................................................................83
3.1 Cabinet Exterior................................................................................................................................................84
3.2 Cabinet Engineering Specifications..................................................................................................................84
3.3 Cabinet Application Scenarios.........................................................................................................................88
3.4 Cabinet Interior.................................................................................................................................................89
3.5 TMC11H Components.....................................................................................................................................92
3.5.1 DCDU-12B..............................................................................................................................................92
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

iii

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Contents

3.5.2 DCDU-12C..............................................................................................................................................98
3.5.3 FAN 02D...............................................................................................................................................102
3.5.4 Filler Module.........................................................................................................................................102
3.5.5 Junction Box..........................................................................................................................................103
3.5.6 ELU.......................................................................................................................................................105
3.5.7 Door Status Sensor................................................................................................................................111
3.5.8 AC Heater..............................................................................................................................................114
3.5.9 SOU.......................................................................................................................................................115
3.6 TMC11H Cables.............................................................................................................................................116
3.6.1 Cable List...............................................................................................................................................116
3.6.2 Cable Connections.................................................................................................................................119
3.6.3 PGND Cable..........................................................................................................................................120
3.6.4 Equipotential Cable...............................................................................................................................126
3.6.5 Power Cables.........................................................................................................................................131
3.6.6 Signal Cables.........................................................................................................................................144

4 IBBS200D Cabinet.....................................................................................................................151
4.1 Cabinet Exterior..............................................................................................................................................152
4.2 Cabinet Engineering Specifications................................................................................................................152
4.3 Cabinet Interior...............................................................................................................................................154
4.4 IBBS200D Components.................................................................................................................................155
4.4.1 Fan Mounting Frame.............................................................................................................................155
4.4.2 CMUEA.................................................................................................................................................159
4.4.3 Power Distribution Box.........................................................................................................................162
4.4.4 Storage Battery......................................................................................................................................164
4.4.5 ELU.......................................................................................................................................................165
4.4.6 Heating Film..........................................................................................................................................171
4.4.7 Door Status Sensor................................................................................................................................172
4.4.8 Temperature Sensor...............................................................................................................................175
4.5 IBBS200D Cables...........................................................................................................................................180
4.5.1 Cable List...............................................................................................................................................180
4.5.2 Cable Connections.................................................................................................................................182
4.5.3 PGND Cable..........................................................................................................................................184
4.5.4 Equipotential Cable...............................................................................................................................190
4.5.5 Power Cables.........................................................................................................................................195
4.5.6 Signal Cables.........................................................................................................................................202

5 IBBS200T Cabinet......................................................................................................................208
5.1 Cabinet Exterior..............................................................................................................................................209
5.2 Cabinet Engineering Specifications................................................................................................................209
5.3 Cabinet Interior...............................................................................................................................................211
5.4 IBBS200T Components..................................................................................................................................213
5.4.1 TEC........................................................................................................................................................213
5.4.2 CMUEA.................................................................................................................................................214
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

iv

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Contents

5.4.3 Power Distribution Box.........................................................................................................................218


5.4.4 Storage Battery......................................................................................................................................220
5.4.5 ELU.......................................................................................................................................................221
5.4.6 Door Status Sensor................................................................................................................................227
5.4.7 Temperature Sensor...............................................................................................................................230
5.5 IBBS200T Cables...........................................................................................................................................235
5.5.1 Cable List...............................................................................................................................................235
5.5.2 Cable Connections.................................................................................................................................237
5.5.3 PGND Cable..........................................................................................................................................239
5.5.4 Equipotential Cable...............................................................................................................................244
5.5.5 Power Cables.........................................................................................................................................249
5.5.6 Signal Cables.........................................................................................................................................255

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

1 Changes in APM30H&TMC11H&IBBS200D&IBBS200T
(Ver.D) Product Description

Changes in

APM30H&TMC11H&IBBS200D&IBBS200T
(Ver.D) Product Description
This chapter describes the changes in the APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description.

03 (2013-01-15)
This is the third commercial release.
Compared with 02 (2012-12-30), no information is added.
Compared with 02 (2012-12-30), this issue incorporates the following changes.
Topic

Change Description

l EPU05A-02 or EPU05A-04
Power Cable

Changed the input power cable for the APM30H to the


EPU05A-02 or EPU05A-04 power cable and the
EPU05A-03 or EPU05A-05 power cable.

l Power Cable for the


EPU05A-03 or EPU05A-05
l 3.5.1 DCDU-12B
l 3.5.2 DCDU-12C
l 2.6.1 EPU05A
l 2.6.3 FAN 02D
l PMU 11A

Changed the input power cable for the TMC11H to the


DCDU-12B power cable and the DCDU-12C power
cable.
Specified the models of the EPU, fan assembly, PMU,
and PSU.Specified the models of the EPU, fan
assembly, PMU, and PSU.

l PSU (R4850G2)

Compared with 02 (2012-12-30), no information is deleted.

02 (2012-12-30)
This is the second commercial release.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

1 Changes in APM30H&TMC11H&IBBS200D&IBBS200T
(Ver.D) Product Description

Compared with 01 (2012-11-10), no information is added.


Compared with 01 (2012-11-10), this issue incorporates the following changes.
Topic

Change Description

Power Cables for a Fan Assembly

Added the description of the cables


complying with British Standards (BS).

Input Power Cable for a TMC11H


Power Cables for the Fan in an IBBS200D
TEC Power Cables
Power Cables in a Battery Cabinet
DCDU-12B Input Power Cable
Technical Specifications of an APM30H

Modified the input protection.

Compared with 01 (2012-11-10), no information is deleted.

01 (2012-11-10)
This is the first commercial release.
Compared with draft A (2012-09-15), no information is added or deleted.
Compared with draft A (2012-09-15), some descriptions are optimized, and changed the
APM30H (Ver.D2) and TMC11H (Ver.D2) cabinets to APM30H (Ver.D) and TMC11H
(Ver.D), respectively.
Compared with draft A (2012-09-15), all information about the APM30H (Ver.D1) and
TMC11H (Ver.D1) is deleted from this issue.

Draft A (2012-09-15)
This is a draft.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

APM30H Cabinet

About This Chapter


This chapter describes the APM30H cabinet exterior, engineering specifications, application
scenarios, as well as boards, modules, and cables in the APM30H cabinet.
2.1 Cabinet Exterior
The advanced power module with heat exchanger (APM30H) is used for Huawei wireless
products outdoors. It is small and easy to transport.
2.2 Cabinet Engineering Specifications
This section describes the engineering specifications of the APM30H, including the power
specifications, equipment specifications, surge protection specifications, and environment
specifications.
2.3 Engineering Specifications of Customer Equipment in APM or TMC Series Cabinets
The customer equipment to be installed in APM or TMC series cabinets must meet the
requirements for engineering specifications.
2.4 Cabinet Application Scenarios
The APM30H can apply to a distributed base station or a separated macro base station.
2.5 Cabinet Interior
The APM30H supplies DC power to the distributed or separated macro base station in outdoor
scenarios. It provides space for both the BBU and transmission equipment. If an AC heater or
an SOU is not configured in the APM30H and one BBU is installed, 5 U space is provided for
the customer equipment.
2.6 Components in an APM30H
This section describes the mandatory and optional components in an APM30H.
2.7 APM30H Cables
The APM30H cables consist of the power cables, equipotential cables, PGND cables, and signal
cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

2.1 Cabinet Exterior


The advanced power module with heat exchanger (APM30H) is used for Huawei wireless
products outdoors. It is small and easy to transport.
The following figure shows the exterior of the APM30H.
Figure 2-1 Exterior of the APM30H

2.2 Cabinet Engineering Specifications


This section describes the engineering specifications of the APM30H, including the power
specifications, equipment specifications, surge protection specifications, and environment
specifications.

Power Specifications
The APM30H supports the input power of 220 V AC single-phase, 220/380 V AC three-phase,
110 V AC dual-live-wire, 120 V AC dual-live-wire, and the output power of -48 V DC. When
AC power is used, the base station converts AC power into -48 V DC power.
The following table lists the AC input voltage range supported by the APM30H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-1 AC input specifications


Power
Supply

Rated
Voltage

Operating
Voltage

Rated
Input
Current

Input
Voltage
Frequency

Input
Protection

220 V AC
single-phase

200 V AC to
240 V AC

176 V AC to
290 V AC

80 A

45 Hz to 65
Hz

220/380 V
AC threephase

200/346 V
AC to
240/415 V
AC

176/304 V
AC to
290/500 V
AC

32 A

110 V AC
dual-livewire

100/200 V
AC to
120/240 V
AC

90/180 V AC
to 135/270 V
AC

80 A

120 V AC
dual-livewire

120/208 V
AC to
127/220 V
AC

105/176 V
AC to
150/260 V
AC

80 A

l Overvolt
age
protectio
n: The
system
generates
an alarm
when the
input
voltage
exceeds
the AC
overvolta
ge alarm
threshold
(301 V by
default).
l Undervol
tage
protectio
n: The
system
generates
an alarm
when the
input
voltage is
lower
than the
AC
undervolt
age alarm
threshold
(74 V by
default).

Heat consumption in the APM30H: 1500 W (heat dissipation capability at the ambient
temperature of 50oC or 122oF) (including the BBU, power system, and transmission equipment)

Equipment Specifications
The following table lists the equipment specifications of the APM30H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-2 Equipment specifications


Item

Specifications

Remarks

Dimensions (H x
W x D)

Cabinet (without the


base): 700 mm x 600
mm x 480 mm (27.56
in. x 23.62 in. x 18.90
in.)

Base: 200 mm x 600


mm x 434 mm (7.87 in.
x 23.62 in. x 17.09 in.)
Space for the
customer
equipment (H x
W x D)

Configured with one


BBU: 5 U x 19 in. x 380
mm

Cabinet weight

68 kg (149.94 lb)

The depth includes 280 mm (11.02 in.) away


from the rear of the subrack mounting ears and
100 mm (3.94 in.) away from the front.

Configured with two


BBUs: 3U x 19 in. x
380 mm
Total weight of the equipment
l Including the cabinet frame, inner air
circulation fan, outer air circulation fan,
core of the heat exchanger, EPU subrack,
and cables
l Excluding the BBU, customer transmission
equipment, PMU, and PSUs
87 kg (191.84 lb)

Weight with full configuration


l Including the total weight of the equipment,
one PMU, five PSUs, and one BBU
l Excluding the customer transmission
equipment

Cabling and
maintenance
space at the front

70 mm (2.76 in.)

Surge Protection Specifications


The following table lists the surge protection specifications of the APM30H.
Table 2-3 Surge protection specifications
Item

Specifications

Surge protection for AC


input ports

In differential mode:
l Rated through-current capacity (8/20 us): 30 kA
l Maximum through-current capacity (8/20 us): 60 kA

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Item

2 APM30H Cabinet

Specifications
In common mode:
l Rated through-current capacity (8/20 us): 30 kA
l Maximum through-current capacity (8/20 us): 60 kA

Surge protection for DC


output ports

l In differential mode (8/20 us): 10 kA


l In common mode (8/20 us): 20 kA
The DC output corresponds to the secondary load.
NOTE
The surge protection capacity of the shield layer in an RRU power cable
is 40 kA.

Surge protection for signal


ports

E1/T1 port:
l In differential mode (8/20 us): 3 kA
l In common mode (8/20 us): 5 kA
FE port:
l In differential mode (8/20 us): 3 kA
l In common mode (8/20 us): 5 kA

Environment Specifications
The APM30H can be used outdoors. The following table lists the environment specifications of
the APM30H.
Table 2-4 Environment specifications
Item

Specifications

Remarks

Operating
temperatur
e

-40oC to +50oC (-40oF to +122oF)

A heater is required when the


temperature is lower than -20oC
(-4oF). A sun shield is required when
the temperature is higher than 50oC
(122oF).
NOTE
The temperature at which the heater is
required is specified as the local average
lowest temperature of each day in the
coldest month of the year.

Issue 03 (2013-01-15)

Relative
humidity

5% RH to 100% RH

Altitude

-60 m to +4000 m (-196.85 ft to


+13123.2 ft)

From the altitude of 1800 m (5905.44


ft), the maximum operating
temperature drops by 1oC (33.8oF)
each time the altitude increases by 220
m (721.78 ft).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Item

Specifications

Remarks

Wind
speed

67 m/s

Storage
temperatur
e

-40oC to +70oC (-40oF to +158oF)

Dustproof
and
waterproof

IP55

Noise

When the heat consumption of the


cabinet is equal to or less than 700 W,
the noise is equal to or less than 61
dBA at the temperature of 25oC
(77oF) and equal to or less than 67
dBA at the temperature of 45oC
(113oF).

Meeting the ETS 300 753 4.1E


standard (rural area)

When the heat consumption of the


cabinet is equal to 1050 W or between
700 W and 1050 W, the noise is equal
to or less than 66 dBA at the
temperature of 25oC (77oF) and equal
to or less than 76 dBA at the
temperature of 45oC (113oF).

Meeting the ETS 300 753 4.1E


standard (urban area)

2.3 Engineering Specifications of Customer Equipment in


APM or TMC Series Cabinets
The customer equipment to be installed in APM or TMC series cabinets must meet the
requirements for engineering specifications.
The customer equipment to be installed in the APM30H (Ver.B), APM30H (Ver.C), APM30H
(Ver.D), TMC11H (Ver.B), TMC11H (Ver.C), or TMC11H (Ver.D) must meet the following
requirements:
l

Dimension requirements
The dimension requirements are shown in Figure 2-2.
The width is 19 inch.
The depth of the customer equipment which uses natural ventilation or supports heat
dissipation from left to right is less than or equal to 280 mm (11.02 in.). The depth of
the customer equipment which supports heat dissipation from front to rear is less than
250 mm (9.84 in.).
The cabling space in front of the front panel is less than or equal to 100 mm (3.94 in.).

Issue 03 (2013-01-15)

Heat dissipation requirements

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

If the customer equipment has built-in fans, the fans must dissipate heat out from left
to right or from front to rear.
If the customer equipment does not have built-in fans but uses natural ventilation, a
minimum of 1 U space must be reserved above and below the customer equipment to
ensure heat dissipation.
l

Temperature requirements
The following table lists the temperature requirements.
Table 2-5 Temperature requirements for the customer equipment
Highest Environmental
Temperature

Lowest Operating
Temperature for the
Customer Equipment

Highest Operating
Temperature for the
Customer Equipment

Equal to or lower than 40


C (104F)

Equal to or lower than -10 Equal to or higher than 55


C (14F)
C (131F)

Higher than 40C (104F)

Equal to or lower than -10 Equal to or higher than 60


C (14F)
C (140F)

Figure 2-2 Dimension requirements and heat dissipation requirements

(1) Equipment using natural


ventilation

(2) Equipment dissipating heat out (3) Equipment dissipating heat out
from left to right
from front to rear

The customer equipment to be installed in the APM30, APM30H (Ver.A), TMC, or TMC11H
(Ver.A) must meet the following requirements:
l

Dimension requirements
The dimension requirements are shown in Figure 2-3.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

The width is 19 inch.


The depth of the customer equipment which uses natural ventilation or supports heat
dissipation from left to right is less than or equal to 310 mm (12.20 in.). The depth of
the customer equipment which supports heat dissipation from front to rear is less than
280 mm (11.02 in.).
The cabling space in front of the front panel is less than or equal to 70 mm (2.76 in.).
l

Heat dissipation requirements


If the customer equipment has built-in fans, the fans must dissipate heat out from left
to right or from front to rear.
If the customer equipment does not have built-in fans but uses natural ventilation, a
minimum of 1 U space must be reserved above and below the customer equipment to
ensure heat dissipation.

Temperature requirements
The following table lists the temperature requirements.
Table 2-6 Temperature requirements for the customer equipment
Highest Environmental
Temperature

Lowest Operating
Temperature for the
Customer Equipment

Highest Operating
Temperature for the
Customer Equipment

Equal to or lower than 40


C (104F)

Equal to or lower than -10 Equal to or higher than 55


C (14F)
C (131F)

Higher than 40C (104F)

Equal to or lower than -10 Equal to or higher than 60


C (14F)
C (140F)

Figure 2-3 Dimension requirements and heat dissipation requirements

(1) Equipment using natural


ventilation

Issue 03 (2013-01-15)

(2) Equipment dissipating heat out (3) Equipment dissipating heat out
from left to right
from front to rear

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

10

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

2.4 Cabinet Application Scenarios


The APM30H can apply to a distributed base station or a separated macro base station.

Distributed Base Stations Configured with an APM30H


NOTE

Distributed or separated base stations configured with an IBBS200D and with an IBBS200T are the same
in scenarios configured with an APM30H. This section uses the IBBS200D as an example.

The following figure shows the distributed base station where an APM30H is stacked on a battery
cabinet.
Figure 2-4 Distributed base station where an APM30H is stacked on a battery cabinet

In a distributed base station, an APM30H is configured as follows:

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

11

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

The APM30H provides 5 U space for transmission equipment and uses an embedded power
system to feed -48 V DC power into the distributed base station, transmission equipment,
and storage battery groups in the battery cabinet.

When the mains power supply is unavailable, storage battery groups feed -48 V DC power
into the distributed base station and transmission equipment.

Separated Macro Base Stations Configured with an APM30H


The following figure shows the separated macro base station configured with an APM30H.
Figure 2-5 Separated macro base station configured with an APM30H

In a separated macro base station, an APM30H is configured as follows:


l

The APM30H provides 5 U space for transmission equipment and uses an embedded power
system to feed -48 V DC power into the BBU, RFUs, transmission equipment, and storage
battery groups in the battery cabinet.

When the mains power supply is unavailable, storage battery groups feed -48 V DC power
into the BBU, RFUs, and transmission equipment.

The APM30H reports alarms from the fans of the RFC, door status sensor, DCDU, and
battery cabinet.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

12

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

2.5 Cabinet Interior


The APM30H supplies DC power to the distributed or separated macro base station in outdoor
scenarios. It provides space for both the BBU and transmission equipment. If an AC heater or
an SOU is not configured in the APM30H and one BBU is installed, 5 U space is provided for
the customer equipment.
The following figure shows the interior of the APM30H. The following figure uses an APM30H
in the separated macro base station as an example. For more details about the interior of the
APM30H in a distributed base station, see DBS3900 Hardware Description.
Figure 2-6 Interior of the APM30H

The following table describes the components in the APM30H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

13

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-7 Components in the APM30H


N
o.

Compone
nt

Op
tio
nal
or
Ma
nd
ato
ry

Ma
xim
um
Qu
anti
ty
in a
Sin
gle
Cab
inet

Remarks

Outer air
circulation
assembly

Ma
nda
tor
y

The assembly is installed on the front door, providing inner


and outer air circulation and dissipating heat from the
cabinet.

Junction
box

Ma
nda
tor
y

The junction box converts one AC input to four AC outputs


and is used in the scenario where a service outlet unit
(SOU) and multiple heating films or heaters are
configured.

FAN 02D

Ma
nda
tor
y

The fan assembly is configured with fans and central


monitoring unit type EA (CMUEA), dissipating heat from
the cabinet.

SLPU

Ma
nda
tor
y

l To provide protection for trunk signals, a signal


lightning protection unit (SLPU) is mandatory and
installed in the top 1 U space of the cabinet. It is
configured with the universal E1/T1 lightning
protection unit (UELP) or universal FE lightning
protection unit (UFLP).
l To provide protection for monitoring signals, an SLPU
is optional and installed in the 1 U space below the
BBU. It is configured with two universal signal
lightning protection unit 2 (USLP2) boards.

Issue 03 (2013-01-15)

Door status
sensor

Ma
nda
tor
y

The door status sensor monitors the status (open or closed)


of the cabinet door.

ELU

Ma
nda
tor
y

The electronic label unit (ELU) reports the cabinet type


automatically to facilitate troubleshooting.

EPU05A

Ma
nda
tor
y

The EPU converts AC input power to DC output power


and distributes the DC power to all the components in the
cabinet. The EPU consists of the EPU subrack, PMU, and
PSUs.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

14

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

N
o.

Compone
nt

Op
tio
nal
or
Ma
nd
ato
ry

Ma
xim
um
Qu
anti
ty
in a
Sin
gle
Cab
inet

Remarks

BBU3900

Opt
ion
al

A maximum of two BBU3900s can be configured in an


APM30H.
l The BBU3900 provides physical ports for
communication between the BBU3900 and the BSC or
RNC, and enables interaction between the base station
and the BSC or RNC.
l The BBU3900 provides CPRI ports for communication
between the BBU and RF modules.
l The BBU3900 processes uplink and downlink data.

EMUA

Opt
ion
al

The environment monitoring unit type A (EMUA)


monitors environment of the equipment.

10

Filler
module

Ma
nda
tor
y

A filler module is a 1 U high plastic component, which


prevents the heat reflux in the empty space below the BBU.

11

AC heater

Opt
ion
al

The AC heater ensures that components in the cabinet work


within the acceptable temperature range when the
surrounding temperature is low. It can be installed in the 1
U space at the bottom of the cabinet. If both an AC heater
and an SOU are configured, the heater is installed in the 1
U space above the SOU.

12

SOU

Opt
ion
al

The service outlet unit (SOU) transfers AC power supply


to the customer equipment. It can be installed in the 1 U
space at the bottom of the cabinet.

2.6 Components in an APM30H


This section describes the mandatory and optional components in an APM30H.

2.6.1 EPU05A
An EPU05A converts AC power into DC power and distributes power.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

15

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Components of an EPU05A-02 or EPU05A-04


An EPU05A-02 or EPU05A-04 consists of an EPU05A-02 or EPU05A-04 subrack, a PMU 11A,
and PSUs (R4850G2).
The following figure shows the components of an EPU05A-02 or EPU05A-04.
Figure 2-7 Components of an EPU05A-02 or EPU05A-04

(1) PMU 11A

(2) PSU (R4850G2)

(3) Filler panel

(4) EPU05A-02 or EPU05A-04 Subrack

The following table describes the components of an EPU05A-02 or EPU05A-04.


Table 2-8 Components of an EPU05A-02 or EPU05A-04
Module

Description

PMU 11A

It is installed in slot 0.

PSU (R4850G2)

A minimum of two PSUs must be configured.


The PSUs must be installed in adjacent slots
in the sequence of slot 1 to slot 5.

Filler panel

A filler panel must be installed in a slot not


configured with a PSU (R4850G2).

EPU05A-02 or EPU05A-04 subrack

Figure 2-7 shows how slots are numbered in


an EPU05A-02 or EPU05A-04 subrack.

Components of an EPU05A-03 or EPU05A-05


An EPU05A-03 or EPU05A-05 consists of an EPU05A-03 or EPU05A-05 subrack, a PMU 11A,
and PSUs (R4850G2).
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

16

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

The following figure shows the components of the EPU05A-03 or EPU05A-05.


Figure 2-8 Components of the EPU05A-03 or EPU05A-05

(1) PMU 11A

(2) PSU (R4850G2)

(3) Filler panel

(4) EPU05A-03 or EPU05A-05 Subrack

The following table describes the components of the EPU05A-03 or EPU05A-05.


Table 2-9 Components of the EPU05A-03 or EPU05A-05
Module

Description

PMU 11A

It is installed in slot 0.

PSU (R4850G2)

A minimum of two PSUs must be configured.


The PSUs must be installed in adjacent slots
sequentially from slot 1 to slot 5.

Filler panel

A maximum of five PSUs can be configured


in the APM30H (Ver.D). Filler panels must
be installed in vacant slots.

EPU05A-03 or EPU05A-05 subrack

Figure 2-8 shows how slots are numbered in


the EPU05A-03 or EPU05A-05 subrack.

EPU05A-02 or EPU05A-04 Subrack


An EPU05A-02 or EPU05A-04 subrack houses the PMU 11A and PSUs (R4850G2). It also
distributes AC input power and DC output power. An EPU05A-02 or EPU05A-04 applies to a
separated macro base station.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

17

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Application of an EPU05A-02 or EPU05A-04 Subrack


The following table describes the application of an EPU05A-02 or EPU05A-04 subrack.
Table 2-10 Application of an EPU05A-02 or EPU05A-04 subrack
Type

Description

Application

EPU05A
-02

It is a 5 U subrack and houses


a maximum of five PSUs
(R4850G2) and one PMU. It
distributes large- and smallcapacity DC power.

Separated macro base station with external 220


V AC input

EPU05A
-04

It is a 5 U subrack and houses


a maximum of five PSUs
(R4850G2) and one PMU. It
distributes large- and smallcapacity DC power.

Separated macro base station with external 110


V AC input

Exterior
Figure 2-9 and Figure 2-10 show the exteriors of EPU05A-02 and EPU05A-04 subracks,
respectively.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

18

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-9 Exterior of an EPU05A-02 subrack

(1) AC surge protector

(2) PSU1/4 circuit breaker, (3) AC OUTPUT circuit


PSU2/5 circuit breaker, and breaker
PSU3 circuit breaker

(4) BAT circuit breaker

(5) Circuit breaker for


RFC1

(6) Circuit breaker for


RFC2

(7) Output port for the


storage battery

(8) RFC1 output port

(9) RFC2 output port

(10) LOAD0 to LOAD8


output ports

(11) Spare fuse box

(12) Short-circuiting bar(1)

(13) AC INPUT

(14) AC OUTPUT

NOTE

When a short-circuiting bar is installed on the AC INPUT wiring terminal to connect the L1, L2, and L3
terminals, the EPU subrack supplies 220 V AC single-phase power. When the short-circuiting bar is not
installed on the AC INPUT wiring terminal, the EPU subrack supplies 220 V AC three-phase power.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

19

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-10 Exterior of an EPU05A-04 subrack

(1) AC surge protector

(2) PSU circuit breaker

(3) AC OUTPUT1/AC
OUTPUT2 circuit breaker

(5) Circuit breaker for


RFC1

(6) Circuit breaker for


RFC2

(7) Output port for the storage (8) RFC1 output port
battery

(9) RFC2 output port

(10) LOAD0 to LOAD8 (11) Spare fuse box


output ports

(12) AC INPUT

(13) AC OUTPUT

(4) BAT circuit breaker

Function
An EPU05A-02 or EPU05A-04 subrack distributes AC and DC power.
l

An EPU05A-02 or EPU05A-04 subrack performs the following AC power distribution


functions:
Provides two AC outputs. One is used for the service outlet unit (SOU). The other one
is connected to the AC junction box on the left of the cabinet, and divided into four AC
power outputs, which are then provided for the heater or heating film.
Reports AC input surge protection alarms.

An EPU05A-02 or EPU05A-04 subrack provides 12 DC outputs for a separated macro base


station.

Port
The following figure shows the power input and output ports on an EPU05A-02 or EPU05A-04
subrack. Table 2-11 and Table 2-12 list the ports in detail.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

20

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-11 Power input and output ports on an EPU05A-02 or EPU05A-04 subrack

Table 2-11 AC input and output ports on an EPU05A-02 or EPU05A-04 subrack


AC Input/Output
Terminal

Wiring Terminal

Connector

AC INPUT

L1, L2, L3, N

OT terminal (M6)

AC OUTPUT

L1, N1, L2, N2

Table 2-12 DC input and output ports and terminals on an EPU05A-02 or EPU05A-04 subrack

Issue 03 (2013-01-15)

DC output
ports

DC Power
Supply Unit

Protector

Protector
Specification

Connector

LOAD0 and
LOAD1

BBU

Fuse(3)

2x30 A

EPC4 or EPC6

LOAD2

FAN

LOAD3

TM_0(1)

LOAD4

TM_1

LOAD5

TM_2 or
EMUA

LOAD6

TM_3 or BBU

LOAD7

TMC

LOAD8

IBBS(2)

1x30 A

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

21

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

DC output
ports

DC Power
Supply Unit

Protector

Protector
Specification

Connector

RFC1

RFC1

Breaker

1x125 A

RFC2

RFC2

OT terminal
(M6)

BAT

BAT

1x250 A

OT terminal
(M8)

NOTE

(1) TM is the customer transmission equipment. LOAD3, LOAD4, LOAD5, and LOAD6 are DC output
terminals for the transmission equipment, supporting four DC outputs.
(2) When the IBBS200D is configured, LOAD8 is the DC output port for the IBBS200D fan power cable.
When IBBS200T is configured, LOAD8 is the DC output port for the IBBS200T TEC power cable.
(3) The spare fuse box contains five 5 A fuses and three 30 A fuses for onsite replacement.

Circuit Breaker
There are several circuit breakers on the EPU05A-02 or EPU05A-04 subrack panel to control
the DC outputs. The following figure shows the positions of circuit breakers and the following
table describes the specifications of circuit breakers.
Figure 2-12 Circuit breakers on an EPU05A-02 or EPU05A-04 subrack

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

22

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-13 Circuit breakers on an EPU05A-02 or EPU05A-04 subrack


Circuit Breaker

Silkscreen on the Panel

Requirement for the


Circuit Breaker

PSU circuit breakers


(EPU05A-02)

PSU1/4

1x40 A/1 P

PSU2/5

1x40 A/1 P

PSU3

1x25 A/1 P

PSU circuit breakers


(EPU05A-04)

PSU

1x100 A/2 P

AC output circuit breaker


(EPU05A-02)

AC OUTPUT

1x16 A/2 P

AC output circuit breaker


(EPU05A-04)

AC OUTPUT1 and AC
OUTPUT2

2x16 A/1 P

Storage battery circuit


breaker

BAT

1x125 A/2 P

RFC circuit breaker

RFC 1 and RFC 2

2x125 A/1 P

Technical Specifications
The following table describes the technical specifications of an EPU05A-02 or EPU05A-04
subrack.
Table 2-14 Technical specifications of an EPU05A-02 or EPU05A-04 subrack
Component

Specifications

Output voltage

-44 V DC to -58 V DC

Rated voltage

-53.5 V DC

Output current

0 A to 250 A

EPU05A-03 or EPU05A-05 Subrack


An EPU05A-03 or EPU05A-05 subrack houses the PMU 11A and PSUs (R4850G2). It also
distributes AC and DC power. The EPU05A-03 and EPU05A-05 subrack applies to a distributed
base station.

Applications of an EPU05A-03 or EPU05A-05 Subrack


The following table describes the applications of an EPU05A-03 or EPU05A-05 subrack.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

23

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-15 Applications of the EPU05A-03 or EPU05A-05 subrack


Type

Description

Application

EPU05A
-03

It is a 5 U subrack and houses


a maximum of five PSUs
(R4850G2) and one PMU
11A. It distributes large- and
small-capacity DC power.

Distributed base station supplied with 220 V AC


power

EPU05A
-05

It is a 5 U subrack and houses


a maximum of five PSUs
(R4850G2) and one PMU
11A. It distributes large- and
small-capacity DC power.

Distributed base station supplied with 110 V AC


power

Exteriors
Figure 2-13 and Figure 2-14 show the exteriors of the EPU05A-03 and EPU05A-05 subracks,
respectively.
Figure 2-13 Exterior of the EPU05A-03 subrack

(1) AC surge protector

Issue 03 (2013-01-15)

(2) PSU1/4 circuit


(3) AC OUTPUT circuit
breaker, PSU2/5 circuit breaker
breaker, and PSU3 circuit
breaker

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

(4) BAT circuit breaker

24

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

(5) Circuit breaker for RFC (6) Output terminal for


1
storage batteries

(7) Output terminal for


RFC 1

(8) Output terminals for


LOAD 0 to LOAD 8

(9) Output terminals for


RRU 0 to RRU 5

(10) Spare fuse box

(11) Short-circuiting bar(1) (12) AC INPUT

(13) AC OUTPUT

NOTE

When a short-circuiting bar is installed on the AC INPUT wiring terminal to connect the L1, L2, and L3
terminals, the EPU subrack supports 220 V AC single-phase power. When no short-circuiting bar is
installed on the AC INPUT wiring terminal, the EPU subrack supports 220 V AC three-phase power.

Figure 2-14 Exterior of the EPU05A-05 subrack

(1) AC surge protector

(2) PSU circuit breaker

(3) AC OUTPUT 1 or AC (4) BAT circuit breaker


OUTPUT 2 circuit breaker

(5) Circuit breaker for RFC (6) Output terminal for


1
storage batteries

(7) Output terminal for


RFC 1

(8) LOAD 0 to LOAD 8


output terminals

(9) Output terminals for


RRU 0 to RRU 5

(11) AC INPUT

(12) AC OUTPUT

(10) Spare fuse box

Function
An EPU05A-03 or EPU05A-05 distributes AC and DC power.
l

An EPU05A-03 or EPU05A-05 subrack performs the following AC power distribution


functions:
Provides two AC outputs. One is used for the service outlet unit (SOU). The other one
is connected to the junction box on the left side of the cabinet interior, and divided into
four AC power outputs, which are then provided to the heater or heating film.
Reports AC input surge protection alarms.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

25

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

An EPU05A-03 or EPU05A-05 subrack provides 17 DC outputs for a distributed base


station.

Terminals
The following figure shows the power input and output terminals on the EPU05A-03 or
EPU05A-05 subrack, as shown in Table 2-16, Table 2-17.
Figure 2-15 Power input and output terminals on the EPU05A-03 or EPU05A-05 subrack

Table 2-16 AC input and output terminals on the EPU05A-03 or EPU05A-05 subrack
AC Input/Output
Terminal

Wiring Terminal

Connector

AC INPUT

L1, L2, L3, N

OT terminal (M6)

AC OUTPUT

L1, N1, L2, N2

Table 2-17 DC input and output terminals on the EPU05A-03 or EPU05A-05 subrack

Issue 03 (2013-01-15)

DC Output
Terminal

DC Power
Supply Unit

Protector

Protector
Specification

Connector

LOAD 0 and
LOAD 1

BBU

Fuse(3)

2x30 A

EPC 4 or EPC 6

LOAD 2

FAN

1x30 A

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

26

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

DC Output
Terminal

DC Power
Supply Unit

LOAD 3

TM_0(1)

LOAD 4

TM_1

LOAD 5

TM_2 or EMUA

LOAD 6

TM_3 or BBU

LOAD 7

TMC

LOAD 8

IBBS(2)

RRU 0 to RRU
5

RRU

RFC 1

RFC

BAT

BAT

2 APM30H Cabinet

Protector

Protector
Specification

Connector

EPC 5
Breaker

1x125 A

OT terminal (M6)

1x250 A

OT terminal (M8)

NOTE

(1) TM is the customer transmission equipment. LOAD3, LOAD4, LOAD5, and LOAD6 are DC output
terminals for the transmission equipment, supporting four DC outputs.
(2) When the IBBS200D is configured, LOAD8 is the DC output terminal connecting to the IBBS200D
fan power cable. When IBBS200T is configured, LOAD8 is the DC output terminal connecting to the
IBBS200T TEC power cable.
(3) The spare fuse box can provide five 5 A fuses and three 30 A fuses, which can be used to replace broken
ones onsite.

Circuit Breakers
There are several circuit breakers on the EPU05A-03 or EPU05A-05 subrack panel to control
the DC outputs. The following figure shows the positions of the circuit breakers and the following
table describes the specifications of the circuit breakers.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

27

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-16 Circuit breakers on the EPU05A-03 or EPU05A-05 subrack

Table 2-18 Specifications of the circuit breakers on the EPU05A-03 or EPU05A-05 subrack

Issue 03 (2013-01-15)

Circuit Breaker

Silkscreen

Requirement for the


Circuit Breaker

PSU circuit breakers


(EPU05A-03)

PSU1/4

1x40 A/1 P

PSU2/5

1x40 A/1 P

PSU3

1x25 A/1 P

PSU circuit breaker


(EPU05A-05)

PSU

1x100 A/2 P

AC output circuit breaker


(EPU05A-03)

AC OUTPUT

1x16 A/2 P

AC output circuit breakers


(EPU05A-05)

AC OUTPUT1 and AC
OUTPUT2

2x16 A/1 P

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

28

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Circuit Breaker

Silkscreen

Requirement for the


Circuit Breaker

Circuit breaker for storage


batteries

BAT

1x125 A/2 P

RFC circuit breaker

RFC1

1x125 A/1 P

Technical Specifications
The following table describes the technical specifications of the EPU05A-03 or EPU05A-05
subrack.
Table 2-19 Technical specifications of the EPU05A-03 or EPU05A-05 subrack
Component

Specifications

Output voltage

-44 V DC to -58 V DC

Rated voltage

-53.5 V DC

Output current

0 A to 250 A

PMU 11A
A power monitoring unit 11A (PMU 11A) manages the power system and battery, monitors
power distribution, and reports alarms.

Exterior
The following figure shows the exterior of a PMU 11A.
Figure 2-17 Exterior of a PMU 11A

Function
A PMU 11A performs the following functions:
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

29

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Communicates with the upper-level device through an RS485 port.

Manages the power system and the charge and discharge of storage batteries.

Monitors the door status and the temperature of storage batteries.

Monitors power distribution and reports alarms.

Communicates with the battery cabinet through an RS485 port.

Port
The following figure shows the ports on a PMU 11A.
Figure 2-18 Ports on a PMU 11A

The following table describes the ports on a PMU 11A.


Table 2-20 Ports on a PMU 11A
No.

Silkscreen

Connector

Description

GATE

2-pin connector

Connects to a door status sensor.

TEM_BAT

2-pin connector

Connects to a battery temperature sensor.

COM_IN

RJ45 connector

Connects to the BBU or communicates


with the upper-level monitoring board.

COM_OUT

RJ45 connector

Communicates with the lower-level


monitoring board.

COM_485

RJ45 connector

Connects to the monitoring board in the


battery cabinet, and receives monitoring
signals from the battery cabinet.

Indicator
The following table describes the indicators on a PMU 11A.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

30

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-21 Indicators on a PMU 11A


Silksc
reen

Meanin
g

Color

State

Description

RUN

Running
indicator

Green

Steady on

The module is performing startup, selfcheck, loading, and activation.

Blinking (on for


1s and off for 1s)

The PMU 11A is functional and


communicating with the main control
board in the BBU properly. (This status
does not necessarily mean that the PMU
11A has been configured.)

Blinking (on for


0.125s and off
for 0.125s)

The PMU 11A is functional but unable to


communicate properly.

Steady off

The module is faulty or there is no DC


power supply.

Steady on

Alarms are generated, and the module


must be replaced.

Steady off

No alarm is generated.

Blinking (on for


1s and off for 1s)

An alarm is generated and you need to


locate the fault before determining
whether to replace the module.

ALM

Alarm
indicator

Red

DIP Switch
There is a DIP switch on the left panel of the PMU 11A. The DIP switch has eight bits, where
the four least significant bits 1, 2, 3, and 4 define the monitoring address of the PMU 11A, and
the four most significant bits 5, 6, 7, and 8 are not defined but reserved for future use.
ON is indicated by 1, and OFF is indicated by 0. The monitoring address of the PMU 11A is set
to 3 by default before delivery, as shown in the following figure.
Figure 2-19 DIP switch on the left panel of the PMU 11A

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

31

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

NOTE

At a site configured with two or more APM30Hs, if two PMU units are connected to one RS485 bus for
the BBU, the monitoring address of the other PMU is set to 4. That is, the lower four bits of the DIP switch
are set to 0010.

PSU (R4850G2)
A power supply unit (PSU) (R4850G2) converts 110 V AC or 220 V AC power into -48 V DC.

Exterior
The following figure shows the exterior of a PSU (R4850G2).
Figure 2-20 Exterior of a PSU (R4850G2)

Function
A PSU (R4850G2) performs the following functions:
l

Converts 110 V AC or 220 V AC power into -48 V DC and adjusts the output voltage.

Provides protection against overcurrent, overvoltage, and overtemperature for its DC


outputs.

Dissipates heat using its built-in fans.

Indicator
The following figure shows the indicators on a PSU (R4850G2).
Figure 2-21 Indicators on a PSU (R4850G2)

The following table describes the indicators on a PSU (R4850G2).


Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

32

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-22 Indicators on a PSU (R4850G2)


Silkscree
n

Color

State

Description

(1) Power
indicator

Green

Steady on

The board is functional.

Blinking (on for 0.125s


and off for 0.125s)

The PSU is loading software online.

Steady off

The mains supply or the module is faulty.

Steady off

Yes

Steady on

An alarm triggered by an external factor is


generated.

Blinking (on for 1s and


off for 1s)

The communication between the module


and the PMU is interrupted.

Steady off

Yes

Steady on

The module is faulty or is shut down in an


emergency. Locate the fault and replace the
module.

(2)
Protection
indicator

(3) Fault
indicator

Yello
w

Red

2.6.2 Junction Box


The junction box is configured in the BTS3900AL, APM30H, TMC11H, IBBS700D, or
IBBS700T cabinet. When a heater or a heating film is configured, the junction box feeds power
to the heater or the heating film.

Exterior
A junction box is installed on the left inner side of the APM30H, TMC11H, IBBS700D, or
IBBS700T. In the BTS3900AL, the junction box is installed on the right inner side of the cabinet.
The following figure shows the position and exterior of the junction box in the APM30H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

33

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-22 Exterior of the junction box

Functions
The junction box used in the BTS3900AL, APM30H, TMC11H, IBBS700D and IBBS700T
performs the following functions:
l

The PDU05A-01 feeds power to the junction box in the BTS3900AL. The power is divided
into four AC power outputs, which are then provided for the heater in the cabinet.

The EPU subrack feeds power into the junction box in the APM30H. The power is divided
into four AC power outputs, which are then provided for the heater in the cabinet or heating
film in the IBBS200D.

The junction box in the APM30H feeds power into the junction box in the TMC11H. The
power is divided into four AC power outputs, which are then provided for the heater or
service outlet unit (SOU) in the cabinet.

The junction box in the primary cabinet (BTS3900A, BTS3900AL, or TP48600A-H17B1)


feeds power into the junction box in the IBBS700D or IBBS700T. The power is divided
into four AC power outputs, which are then provided for the heater in the cabinet.

Interior
The following figure shows the interior of an AC junction box.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

34

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-23 Interior of an AC junction box

(1) Four AC output L wiring


terminals

(2) Four AC output N wiring


terminals

(3) Four AC output PE wiring


terminals

(4) Cable holes

(5) AC input N wiring terminal

(6) AC input L wiring terminal

2.6.3 FAN 02D


A FAN 02C dissipates heat and detects temperature for an APM30H (Ver.D) or TMC11H
(Ver.D).

Exterior
A FAN 02D consists of the fan subrack, fans, and CMUEA. The following figure shows the
exterior of a FAN 02D.
Figure 2-24 Exterior of a FAN 02D

(1) Fan subrack

(2) Fans

(3) CMUEA

For details about the ports and indicators on the CMUEA, see CMUEA.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

35

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

2.6.4 ELU
An electronic label unit (ELU) reports the cabinet type automatically to facilitate
troubleshooting.

Exterior
The following figure shows the exterior of an ELU.
Figure 2-25 Exterior of an ELU

(1) Shell

(2) RJ45 port

NOTE

The ELU in a BTS3900 or BTS3900L has no shell.

The board collecting information from the ELU varies according to the cabinet, as listed in the
following table.
Table 2-23 Monitoring boards to which an ELU reports information

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Board Collecting
Information from
the ELU

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B) and BTS3900L (Ver.B)

FMUC

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C) and BTS3900L (Ver.C)

FMUE

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D) and BTS3900L (Ver.D)

FMUEA

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

36

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Base Station
Type

Cabinet

Board Collecting
Information from
the ELU

BTS3900A
(Ver.B)

APM30H (Ver.B), TMC11H (Ver.B), RFC


(Ver.B), IBBS200D (Ver.B), and IBBS200T
(Ver.B)

CMUA

BTS3900A
(Ver.C)

APM30H (Ver.C), TMC11H (Ver.C), RFC


(Ver.C), IBBS200D (Ver.C), and IBBS200T
(Ver.C)

CMUE

BTS3900A
(Ver.D)

APM30H (Ver.D), TMC11H(Ver.D), RFC


(Ver.D), IBBS200D(Ver.D), IBBS200T
(Ver.D), and IBBS700D

CMUEA

IBBS700T

CMUF

BTS3900C
(Ver.C)

OMB (Ver.C)

HEUB

BTS3900AL
(Ver.A)

BTS3900AL (Ver.A), IBBS700D, IBBS700T

CCU

Installation Position
Positions of ELUs vary in different cabinets. The following figure shows their positions.
Figure 2-26 Position of the ELU in a BTS3900 cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

37

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-27 Position of the ELU in a BTS3900L cabinet

Figure 2-28 Position of the ELU in an APM30H or IBBS200D cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

38

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

NOTE

An ELU is located on the right inner wall of the APM30H, TMC11H, or RFC, or on the left inner wall of
the IBBS200D or IBBS200T. The preceding figure shows an APM30H and an IBBS200D as an example.

Figure 2-29 Position of the ELU in an OMB

Figure 2-30 Position of the ELU in a BTS3900AL cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

39

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-31 Position of the ELU in a IBBS700D cabinet

NOTE

In the IBBS700D, when the cabinet is configured with a CCU, the ELU is above the CCU. When the cabinet
is not configured with a CCU, the ELU is on the right of the CMUEA.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

40

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-32 Position of the ELU in a IBBS700T cabinet

NOTE

In the IBBS700T, when the cabinet is configured with a CCU, the ELU is above the CCU. When the cabinet
is not configured with a CCU, the ELU is on the left of the CMUF.

2.6.5 Door Status Sensor


A door status sensor reports the status (open or closed) of a door. It is installed in any of the
following cabinets: BTS3900AL, OMB, OMB (Ver.C), APM30H, RFC, TMC11H, IBBS200D,
IBBS200T, IBBS700D, and IBBS700T.

Exterior
A door status sensor consists of a magnet and a switch. The following figures show the exteriors
of them.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

41

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-33 Exterior of the magnet of a door status sensor

(1) Magnetic shell

(2) Magnet

The following figure shows the exterior of the switch of a door status sensor.
Figure 2-34 Exterior of the switch of a door status sensor

Installation Position
Positions of door status sensors vary in different cabinets. The following figure shows their
positions.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

42

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

NOTE

l A door status sensor is installed at the same position in the BTS3900AL (Ver.A), IBBS700D, and
IBBS700T. Figure 2-35 uses the BTS3900AL (Ver.A) as an example.
l A door status sensor is installed at the same position in the OMB and OMB (Ver.C). Figure 2-36 uses
the OMB (Ver.C) as an example.
l A door status sensor is installed at the same position in the following cabinets: APM30H (Ver.B),
APM30H (Ver.C), APM30H (Ver.D), RFC (Ver.B), RFC (Ver.C), RFC (Ver.D), TMC11H (Ver.B),
TMC11H (Ver.C), TMC11H (Ver.D), IBBS200D (Ver.B), IBBS200D (Ver.C), IBBS200D (Ver.D),
IBBS200T (Ver.B), IBBS200T (Ver.C), and IBBS200T (Ver.D). Figure 2-37 uses the APM30H
(Ver.D) as an example.

Figure 2-35 Position of a door status sensor in the BTS3900AL (Ver.A)

Figure 2-36 Position of a door status sensor in the OMB (Ver.C)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

43

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-37 Position of a door status sensor in the APM30H (Ver.D)

2.6.6 Filler Module


A filler module is a standard plastic component, which prevents heat reflux in the empty space
below the BBU and improves the heat dissipation in the cabinet. Filler modules are installed in
the customer space of an APM30H or TMC11H.

Exterior
A filler module is 1 U high. The following figure shows the exterior of a filler module.
Figure 2-38 Exterior of a filler module

Function
A filler module is installed in the customer space below the BBU to prevent heat reflux in the
empty space below the BBU.
NOTE

In an APM30H or TMC11H, the filler module is configured in the customer space by default. Before
installing other modules, first remove the filler module. For details about removing a filler module, see
chapter "Installing Optional Modules and Cables" in the "Installation Guide".

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

44

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

2.6.7 AC Heater
An AC heater is optionally installed in the customer space in an APM30H or TMC11H. It ensures
that the customer equipment in a cabinet works within the acceptable temperature range.

Exterior
The following figure shows the exterior of an AC heater.
Figure 2-39 Exterior of an AC heater

Technical Specifications
The following table lists the technical specifications of an AC heater.
Table 2-24 Technical specifications of an AC heater
Counter

Specification

Temperature range in the cabinet when the


AC heater starts working

< 1oC (6oC)

Temperature range in the cabinet when the


AC heater stops working

> 15oC (3oC)

Rated heating power

330 W

2.6.8 SOU
A service outlet unit (SOU) transfers AC power to the customer equipment. An SOU is optionally
installed in the customer space in an APM30H or TMC11H.

Exterior
An SOU is 1 U high. The following figure shows the exterior of an SOU.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

45

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-40 Exterior of an SOU

(1) Input power port

(2) Breaker

(3) Socket (European standard)

An SOU applies to the four types of sockets meeting the following standards: North American
standard, European standard, Universal standard, and British standard. The following figure
shows the exteriors of the four types of sockets.
Figure 2-41 Exteriors of different types of sockets

Technical Specifications
The following table lists the technical specifications of an SOU.
Table 2-25 Technical specifications of an SOU

Issue 03 (2013-01-15)

Counter

Specification

Dimensions (H x W x D)

482.6 mm x 91 mm x 55 mm (7.87 in. x 23.62


in. x 17.09 in.)

Weight

1.5 kg (3.31 lb)

Input voltage range

200 V AC to 240 V AC

Maximum input current

10 A

Output voltage range

200 V AC to 240 V AC

Maximum output current

10 A

Frequency band

50 Hz or 60 Hz

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

46

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Counter

Specification

Operating temperature

-40oC to +55oC

Altitude

4,000m
NOTE
Above the altitude of 3000 m (9842.52 ft), the
maximum operating temperature drops by 1oC
(33.8oF) as the altitude increases by 100 m (328.08
ft).

Protection class

IP20

2.7 APM30H Cables


The APM30H cables consist of the power cables, equipotential cables, PGND cables, and signal
cables.

2.7.1 Cable List


APM30H cables mainly consist of the PGND cables, equipotential cables, power cables, and
signal cables.

Power Cables, PGND Cables, and Equipotential Cables


The following table lists the power cables, PGND cables, and equipotential cables.
Table 2-26 Power cables, PGND cables, and equipotential cables

Issue 03 (2013-01-15)

Classif
ication

Cable

Cables
to be
installe
d onsite

BTS3900A

One End

The Other End

Connector

Installation
Position

Connector

Installation
Position

OT terminal

L and N
terminals on
the AC
INPUT
terminal
block on the
EPU

Depending
on external
power
equipment

External
power
equipment

2.7.3 PGND
Cable

OT terminal

Ground bar in
the APM30H

OT terminal

Ground
busbar outside
the cabinet

2.7.4
Equipotential
Cable

OT terminal

Ground bar in
the APM30H

OT terminal

Ground bar in
the lower
cabinet

DBS3900

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

47

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Classif
ication

Cables
installe
d before
deliver
y

Cable

2 APM30H Cabinet

One End

The Other End

Connector

Installation
Position

Connector

Installation
Position

DCDU-12B
Power Cable

OT terminal

RFC1 output
port on the
EPU in the
APM30H

OT terminal

RTN(+) and
NEG(-)
terminals on
the INPUT
terminal block
on the
DCDU-12B

FAN 02D
Power Cable

EPC4 or
EPC6
connector

LOAD5 port
on the EPU in
the APM30H

3V3
connector

PWR port on
the fan
assembly in
the APM30H

Power Cable
for an AC
Heater (in the
APM30H)

OT terminal

L0 and N0
terminals on
the AC
junction box
in the
APM30H and
the cabinet
ground bar

C13
connector

Input power
port on the AC
heater

SOU Power
Cable

OT terminal

M4 ground
screw, L2
terminal, and
N2 terminal
on the AC
OUTPUT
terminal
block on the
EPU

C13
connector

INPUT port
on the SOU

Power Cable
for an AC
Junction Box
(in the
APM30H)

OT terminal

M4 ground
screw, L1
terminal, and
N1 terminal
on the AC
OUTPUT
terminal
block on the
EPU

OT terminal

L and N
terminals on
the AC
junction box
in the
APM30H and
the cabinet
ground bar

NOTE

The connection of power cables for optional components depends on the delivery mode. Table 2-26
describes the power cables in a macro base station.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

48

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Signal Cables
The following table describes the signal cables.
Table 2-27 Signal cables
Classi
ficati
on

Cable

Cables
to be
install
ed
onsite
Cables
install
ed
before
deliver
y

One End

The Other End

Connecto
r

Installation
Position

Connect
or

Installation
Position

PMU 11ACMUEA
Monitoring
Signal
Cable

RJ45
connector

COM_IN port on
the PMU

RJ45
connector

COM_OUT port on
the CMUEA on the
fan assembly in the
APM30H

ELU Signal
Cable

RJ45
connector

ELU

RJ45
connector

ELU port on the


CMUEA

Monitoring
Signal
Cable for
the Door
Status
Sensor

2-pin
connector

GATE port on the


PMU

Bare wire

Door status sensor

Monitoring
Signal
Transfer
Cable for
the Fan in
the Front
Door

Interconne
ction
terminal

Transfer terminal
on the front door
of the APM30H

4-pin
connector

FAN_EXT port on
the CMUEA

2.7.2 Cable Connections


This section describes the principles for connecting power cables and signal cables in the
APM30H.

Power Cable Connections


This section describes the power cable connections in the APM30H.

Cable Connections in a Distributed Base Station


The following figure shows the APM30H power cable connections in a distributed base station.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

49

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-42 Power cable connections in a distributed base station

(1) Power Cable for an AC Junction Box

(2) FAN 02D Power Cable (3) Storage Battery Power Cable

(4) DCDU-12B Power Cable

(5) SOU Power Cable

(6) Power Cable for an AC Heater

Cable Connections in a Separated Macro Base Station


The following figure shows the APM30H power cable connections in a separated macro base
station.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

50

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-43 Power cable connections in a separated macro base station

(1) Power Cable for an AC Junction (2) FAN 02D Power Cable
Box

(3) Storage Battery Power Cable

(4) Power Cable for the DC Junction (5) Power Cable for the DC Junction (6) SOU Power Cable
Box in an RFC
Box in an RFC
(7) Power Cable for an AC Heater

Monitoring Signal Cable Connections


This section provides reference for onsite installation of monitoring signal cables.
The following figure shows the monitoring signal cable connections in the APM30H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

51

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-44 Monitoring signal cable connections in the APM30H

(1) Monitoring signal cable for the fans on the front


door

(2) Monitoring signal transfer cable for the fans on the


front door

(3) PMU-CMUEA monitoring signal cable

(4) Monitoring signal cable for the door status sensor


in the APM30H

(5) ELU signal cable

2.7.3 PGND Cable


PGND cables ensure that cabinets and internal components are properly grounded and that base
stations run properly. PGND cables include classified into PGND cables for cabinets and PGND
cables for components.

Exterior
The following figure shows the exterior of a PGND cable.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

52

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-45 Exterior of a PGND cable

(1) One-hole OT terminal

(2) Two-hole OT terminal

NOTE

In most cases, the PGND cable is a yellow and green colored cable. When 110 V dual-live-wire power is
supplied for BTS3900A (Ver.C) and BTS3900A (Ver.D) cabinets, the PGND cables are green.

Description
The cross-sectional areas and maximum lengths of PGND cables vary according to the types of
cabinets. Table 2-28 and Table 2-29 describe PGND cables.
Table 2-28 PGND cables for cabinets

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B) 15 m (49.21


and BTS3900L
ft)
(Ver.B)

25 mm2
(0.039
in.2)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

One-hole
OT
terminal
(M8)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

53

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Issue 03 (2013-01-15)

2 APM30H Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900A
(Ver.B)

RFC (Ver.B)

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.C)

RFC (Ver.C)

8 m (26.25
ft)

25 mm2
(0.039
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.D)

RFC (Ver.D)

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.D)

IBBS700D and
IBBS700T

5 m (16.4 ft)

35 mm2
(0.054
in.2)

The cable
has a onehole OT
terminal
(M6) on
the
cabinet
side and a
one-hole
OT
terminal
(M8) on
the
ground
bar side.

The exterior
is shown by
illustration
1 in the
preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

54

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900AL
(Ver.A)

BTS3900AL
(Ver.A)

8 m (26.25
ft)

35 mm2
(0.054
in.2)

Select
one of the
followin
g
specificat
ions
based on
the onsite
situation:

The exterior
is shown by
illustration
2 or 3 in the
preceding
figure.

l The
cable
has a
twohole
OT
termi
nal
(M6)
at
each
end,
and
the
distan
ce
betwe
en the
two
holes
of
each
twohole
OT
termi
nal is
15.8
mm
(0.62
in.).
l The
cable
has a
twohole
OT
termi

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

55

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base Station
Type

Cabinet

2 APM30H Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

nal
(M6)
on the
cabin
et side
and a
onehole
OT
termi
nal
(M6)
on the
groun
d bar
side.
The
distan
ce
betwe
en the
two
holes
of the
twohole
OT
termi
nal is
15.8
mm
(0.62
in.).
IBBS700D and
IBBS700T

Issue 03 (2013-01-15)

5 m (16.4 ft)

35 mm2
(0.054
in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

The cable
has a onehole OT
terminal
(M6) on
the
cabinet
side and a
one-hole
OT
terminal
(M8) on
the
ground
bar side.

The exterior
is shown by
illustration
1 in the
preceding
figure.

56

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900C
(Ver.C)

OMB (Ver.C)

15 m (49.21
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

DBS3900

APM30H (Ver.B)
series cabinets

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

APM30H (Ver.C)
series cabinets

8 m (26.25
ft)

25 mm2
(0.039
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

APM30H
(Ver.D) series
cabinets

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

Table 2-29 PGND cables for components

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

One-hole
OT
terminal
(M4)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

57

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900A
(Ver.B)

APM30H (Ver.B)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M4)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

IBBS200D
(Ver.B)
IBBS200T
(Ver.B)

BTS3900C
(Ver.C)

OMB (Ver.C)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M6)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

BTS3900AL
(Ver.A)

BTS3900AL

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M6)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

2.7.4 Equipotential Cable


An equipotential cable connects the PGND terminals of two cabinets. It ensures equipotential
bonding between cabinets and safe operation of base stations.

Exterior
The following figure shows the exterior of an equipotential cable.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

58

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-46 Exterior of an equipotential cable

(1) One-hole OT terminal

(2) Two-hole OT terminal

NOTE

In most cases, the equipotential cable is a green and yellow cable. When 110 V dual-live-wire power is
supplied for the cabinets used by the BTS3900A (Ver.C) or BTS3900A (Ver.D), the equipotential cable
is green.

Description
The following table describes equipotential cables.
Table 2-30 Equipotential cables
Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900
(Ver.B)

16 mm2 (0.025 in.2)

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

16 mm2 (0.025 in.2)

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 2 in the preceding
figure.

BTS3900
(Ver.C)
BTS3900
(Ver.D)
BTS3900A
(Ver.B)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

59

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900A
(Ver.C)

The cross-sectional areas of


cables vary according to the
way that cabinets are
combined.

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

l 16 mm2 (0.025 in.2) for


stacked cabinets
l 25 mm2 (0.039 in.2) for
side-by-side cabinets
BTS3900A
(Ver.D)

Issue 03 (2013-01-15)

16 mm2 (0.025 in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

60

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900AL
(Ver.A)

The cross-sectional areas of


cables vary according to the
way that cabinets are
combined.

l When
a
BTS39
00AL
AC
cabinet
is
combi
ned
with a
BTS39
00AL
DC
cabinet
or an
IBBS7
00D/
IBBS7
00T,
each
end of
the
cable
has a
twohole
OT
termin
al
(M6),
and the
distanc
e
betwee
n the
two
holes
of each
twohole
termin
al is
15.8
mm
(0.62
in.).

The exterior is shown by


illustration 2 or 3 in the
preceding figure.

l When a BTS3900AL AC
cabinet is combined with a
BTS3900AL DC cabinet
or an IBBS700D/
IBBS700T, the crosssectional area of the cable
is 35 mm2 (0.054 in.2)
l When a BTS3900AL AC
cabinet is combined with a
TMC11H (Ver.C), the
cross-sectional area of the
cable is 25 mm2 (0.039in.
2).

l When
a

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

61

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Cross-Sectional Area

2 APM30H Cabinet

Connect
or

Exterior

BTS39
00AL
AC
cabinet
is
combi
ned
with a
TMC1
1H
(Ver.C
), the
cable
has a
twohole
OT
termin
al
(M6)
on the
BTS39
00AL
AC
cabinet
side
and a
onehole
OT
termin
al
(M6)
on the
TMC1
1H
(Ver.C
) side.
The
distanc
e
betwee
n the
two
holes
of each
twohole

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

62

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Cross-Sectional Area

2 APM30H Cabinet

Connect
or

Exterior

termin
al is
15.8
mm
(0.62
in.).

2.7.5 Power Cables


This section describes the exteriors, functions, and pin assignments of the power cables in the
APM30H.

EPU05A-02 or EPU05A-04 Power Cable


An EPU05A-02 or EPU05A-04 power cable feeds external AC power into the power system of
an APM30H (Ver.D). An APM30H can be supplied with 220 V AC single-phase, 220 V AC
three-phase, and 110 V or 120 V AC dual-live-wire power.

Exterior
The number of core wires contained in an EPU05A-02 or EPU05A-04 power cable depends on
the power system where the EPU05A-02 or EPU05A-04 is used. The following figure shows
the exteriors of EPU05A-02 or EPU05A-04 power cables in the 220 V AC single-phase scenario.
Figure 2-47 Exteriors of EPU05A-02 or EPU05A-04 power cables in the 220 V AC singlephase scenario

(1) OT terminal

Description
The following table describes EPU05A-02 or EPU05A-04 power cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

63

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-31 EPU05A-02 or EPU05A-04 power cables


Cable

Wire

Color

Cross-Sectional Area

220 V AC three-phase
power cable

L1

Brown

6 mm2 (0.009 in.2)

L2

Black

L3

Gray

Blue

220 V AC singlephase power cable

Brown

Blue

110 V AC dual-livewire

L1

Black

L2

Red

White

25 mm2 (0.039 in.2)

25 mm2 (0.039 in.2)

NOTE

The colors and structures of cables vary according to countries and regions. If cables are purchased locally,
the cables must comply with local rules and regulations.

Power Cable for the EPU05A-03 or EPU05A-05


The power cable for the EPU05A-03 or EPU05A-05 feeds the external AC power into the power
system in the APM30H. The APM30H supports the power supplies of 220 V AC single-phase,
220 V AC three-phase, and 110 V AC or 120 V AC dual-live-wire.

Exterior
The number of core wires contained in the power cable for the EPU05A-03 or EPU05A-05 varies
according to the power systems. The following figure shows the exterior of the power cable for
the EPU05A-03 or EPU05A-05 used in 220 V AC single-phase scenario.
Figure 2-48 Exterior of the power cable for the EPU05A-03 or EPU05A-05 (in 220 V AC singlephase scenario)

(1) OT terminal (M6)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

64

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Description
The following table lists the power cables for the EPU05A-03 or EPU05A-05.
Table 2-32 Power cables for the EPU05A-03 or EPU05A-05
Cable

Wire

Color

Cross-Sectional Area

220 V AC threephase power cable

L1 wire

Brown

6 mm2 (0.009 in.2)

L2 wire

Black

L3 wire

Gray

N wire

Blue

220 V AC singlephase power cable

L wire

Brown

N wire

Blue

110 V AC or 120 V
AC dual-live-wire

L1 wire

Black

L2 wire

Red

N wire

White

25 mm2 (0.039 in.2)

25 mm2 (0.039 in.2)

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and areas. If cables
are purchased locally, the cables must comply with local rules and regulations.

DCDU-12B Power Cable


A DCDU-12B power cable feeds DC power into a DCDU-12B.

Exterior
The types of DCDU-12B power cables vary according to power supply scenarios. The following
figure shows the exteriors of DCDU-12B power cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

65

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-49 Exteriors of DCDU-12B power cables

(1) OT terminal (M6)

Description
The following table describes DCDU-12B power cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

66

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-33 DCDU-12B power cables


Base
Station
Type

Applicatio
n Scenario

Power
Equipme
nt

Cross-Sectional
Area

Maxi
mum
Leng
th

Exterior

Functi
on

BTS3900
(Ver.D)

In DC
scenarios, a
DCDU-12B
is installed
in a
BTS3900
(Ver.D)
cabinet.

External
power
equipment

10 m
(32.8
1 ft)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

In DC
scenarios, a
DCDU-12B
is installed
in a
BTS3900L
(Ver.D)
cabinet.

External
power
equipment

l One group of
cables with a
crosssectional area
of 35 mm2
(0.054 in.2) is
required when
one 160 A
upper-level
circuit breaker
is used.
l Two groups of
cables with a
crosssectional area
of 16 mm2
(0.025 in.2) are
required when
two 80 A
upper-level
circuit
breakers are
used.

When
the
base
station
is
configu
red
with
RFUs
and
RRUs,
a
DCDU
-12B
power
cable
feeds
DC
power
into the
DCDU
-12B,
and
then
the
DCDU
-12B
supplie
s the
power
to the
RRUs.

BTS3900
L (Ver.D)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.
The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.
In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

67

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Base
Station
Type

Applicatio
n Scenario

Power
Equipme
nt

Cross-Sectional
Area

Maxi
mum
Leng
th

Exterior

BTS3900
A (Ver.D)

A
DCDU-12B
is installed
in an RFC
(Ver.D).

l Extern
al
power
equip
ment
in DC
scenari
os

l One group of
cables with a
crosssectional area
of 25 mm2
(0.039 in.2) in
DC scenarios

1.5 m
(4.92
ft)

The
exterior is
shown by
illustratio
n 2 in the
preceding
figure.

l EPU05
A-02
or
EPU05
A-04
in an
APM3
0H in
AC
scenari
os

DBS3900

In DC
scenarios, a
second
DCDU-12B
is installed
in a
TMC11H
(Ver.D)
configured
for the
DBS3900.

External
power
equipment

l Two groups of
cables with a
crosssectional area
of 16 mm2
(0.025 in.2) are
required when
two 80 A
upper-level
circuit
breakers are
used.

Issue 03 (2013-01-15)

In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

l One group of
cables with a
crosssectional area
of 35 mm2
(0.054 in.2) or
two groups of
cables with a
crosssectional area
of 16 mm2
(0.025 in.2) in
AC scenarios

l One group of
cables with a
crosssectional area
of 35 mm2
(0.054 in.2) is
required when
one 160 A
upper-level
circuit breaker
is used.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Functi
on

15 m
(49.2
1 ft)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.
In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

When
the
base
station
is
configu
red
with
RFUs
and
RRUs,
a
DCDU
-12B
power
cable
feeds
DC
power
into the
DCDU
-12B,
and
then

68

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Issue 03 (2013-01-15)

2 APM30H Cabinet

Applicatio
n Scenario

Power
Equipme
nt

Cross-Sectional
Area

Maxi
mum
Leng
th

Exterior

Functi
on

In AC
scenarios
where the
DBS3900
uses the
APM30H
(Ver.D) and
is
configured
with 7 to 12
RRUs, the
DCDU-12B
is installed
in the
APM30H
(Ver.D).

EPU05A03 or
EPU05A05 in the
APM30H

One group of
cables with a
cross-sectional
area of 25 mm2
(0.039 in.2)

1.5 m
(4.92
ft)

The
exterior is
shown by
illustratio
n 2 in the
preceding
figure.

the
DCDU
-12B
supplie
s the
power
to
RFUs,
RRUs,
and
transmi
ssion
equipm
ent.

DBS3900
where the
BBU is
installed on
a wall, 19inch rack, or
IMB03.

External
power
equipment

In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

One group
of cables
with a
crosssectional
area of 25
mm2
(0.039 in.
2)

One group of
cables with a
cross-sectional
area of 16 mm2
(0.023 in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

15 m
(49.2
1 ft)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.
In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

69

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

SOU Power Cable


The power cable for a service outlet unit (SOU) feeds AC power into the SOU from the AC
OUTPUT port on the EPU or EPS.

Exterior
The following figure shows the exterior of an SOU power cable.
Figure 2-50 Exterior of an SOU power cable

(1) C13 connector

(2) OT terminal (M4)

Description
The following table describes an SOU power cable.
Table 2-34 SOU power cable
Wire

Color

Silkscreen

Cross-Sectional Area

W1

Brown

2.5 mm2 (0.004 in.2)

W2

Green and yellow

PE

W3

Blue

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and regions. If cables
are purchased locally, the cables must comply with local rules and regulations.

Power Cable for an AC Heater


The power cable for an AC heater feeds power into an AC junction box from the AC OUTPUT
port on an EPU or EPS. Then the AC junction box distributes power to the AC heater. If an AC
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

70

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

heater is configured in the -48 V DC input scenario, one more AC power input must be added
for the heater. In this case, the maximum length of the power cable for the AC heater is 15 m
(49.21 ft).

Exterior
The following figure shows the exterior of a power cable for an AC heater.
Figure 2-51 Exterior of a power cable for an AC heater

(1) C13 connector

(2) OT terminal (M4)

Description
The following table describes the power cable for an AC heater.
Table 2-35 Power cable for an AC heater
Wire

Color

Silkscreen

Cross-Sectional
Area

W1

Brown

W2

Green and yellow

PE

1.5 mm2 (0.002


in.2)

W3

Blue

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and regions. If cables
are purchased locally, the cables must comply with local rules and regulations.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

71

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

FAN 02D Power Cable


A FAN 02D power cable feeds -48 V DC power into the FAN 02D in an APM30H or TMC11H
(Ver.D).

Exterior
Figure 2-52 and Figure 2-53 show the exterior of a FAN 02D power cable.
Figure 2-52 Exterior of a FAN 02D power cable in most regions

(1) 3V3 connector

(2) EPC4 or EPC6 connector

Figure 2-53 Exterior of a FAN 02D power cable in UK

(1) 3V3 connector

(2) EPC4 or EPC6 connector

Description
The following table describes a FAN 02D power cable.
Table 2-36 FAN 02D power cable

Issue 03 (2013-01-15)

Cable

Wire

Wire Color in Most


Regions

Wire Color in Other


Regions (UK)

FAN 02D power


cable

RTN(+)

Black

Blue

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

72

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Cable

2 APM30H Cabinet

Wire

Wire Color in Most


Regions

Wire Color in Other


Regions (UK)

NEG(-)

Black

Gray

Power Cable for an AC Junction Box


A power cable for the AC junction box feeds AC power from the power devise into the AC
junction box. The power is divided into four AC outputs, which are then provided to other
components, such as the heater or heating film.

Exterior
The following figure shows the exterior of a power cable for an AC junction box.
Figure 2-54 Power cable for an AC junction box

(1) OT terminal

(2) Cord end terminal

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and regions. If cables
are purchased locally, the cables must comply with local rules and regulations.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

73

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Description
The following table describes a power cable for an AC junction box.
Table 2-37 Power cable for an AC junction box
Base
Stati
on
Type

Cabinet

Power
Equipme
nt

Wire

Color

CrossSectional
Area

Exterior

BTS3
900A

APM30H

EPU or EPS
subrack

Brown

Blue

1.5 mm2 (0.002


in.2)

EPU or EPS
subrack,
and
transfered
by AC
junction
box in
APM30H

Brown

The exterior is
shown by
illustration 1 in
the preceding
figure.

Blue

IBBS700
D/
IBBS700
T

EPU
subrack,
and
transfered
by AC
junction
box in
APM30H

Brown

Blue

BTS3900
AL AC

PDU05A-0
1

Brown

Blue

BTS3900
AL DC

PDU05A-0
1, and
transfered
by AC
junction
box in
BTS3900A
L AC

Brown

Blue

IBBS700
D/
IBBS700
T

PDU05A-0
1, and
transfered
by AC
junction
box in

Brown

TMC11H

BTS3
900A
L

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

1.5 mm2 (0.002


in.2)

1.5 mm2 (0.002


in.2)

2.5 mm2 (0.004


in.2)

The exterior is
shown by
illustration 2 in
the preceding
figure.

2.5 mm2 (0.004


in.2)

The exterior is
shown by
illustration 3 in
the preceding
figure.

2.5 mm2 (0.004


in.2)

74

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Stati
on
Type

Cabinet

2 APM30H Cabinet

Power
Equipme
nt

Wire

Color

BTS3900A
L AC

Blue

CrossSectional
Area

Exterior

2.7.6 Signal Cables


This section describes the exteriors, functions, and pin assignments of the signal cables in the
APM30H.

ELU Signal Cable


An electronic label unit (ELU) signal cable transmits the cabinet type to a monitoring board in
the cabinet.

Exterior
The following figure shows the exterior of an ELU signal cable.
Figure 2-55 Exterior of an ELU signal cable

(1) RJ45 connector

Description
The following table describes an ELU signal cable.
Table 2-38 ELU signal cable

Issue 03 (2013-01-15)

X1 End

X2 End

Color

Wire Type

X1.1

X2.1

White

Twisted pair

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

75

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

X1 End

X2 End

Color

X1.2

X2.2

Orange

X1.3

X2.3

White

X1.6

X2.6

Green

X1.5

X2.5

White

X1.4

X2.4

Blue

X1.7

X2.7

White

X1.8

X2.8

Brown

Wire Type

Twisted pair

Twisted pair

Twisted pair

Monitoring Signal Cable for the Door Status Sensor


A monitoring signal cable for the door status sensor is used to inform the monitoring board of
the door status that is obtained from the door status sensor. Cabinets configured with door status
sensors are as follows: APM30H, TMC11H, RFC, IBBS200D, IBBS200T, BTS3900AL, OMB,
IBBS700D and IBBS700T.

Exterior
Monitoring signal cables for door status sensors are classified into three types according to the
cabinets being monitored. Figure 2-56, Figure 2-57, and Figure 2-58 show their exteriors.
Figure 2-56 Exterior of a monitoring signal cable for the door status sensor (1)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

76

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-57 Exterior of a monitoring signal cable for the door status sensor (2)

NOTE

l Cable 1 has a 2-pin straight socket at one end, which is connected to the HPMI. Cable 1 has a bare wire
and a cord end terminal at the other end, which are connected to a door status sensor and a cable terminal
block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has a cord end
terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to the two ports
on one side of the cable terminal block.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

77

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-58 Exterior of a monitoring signal cable for the door status sensor (3)

NOTE

l Cable 1 has a 2-pin straight socket at one end, which is connected to the GATE port on the PMU. Cable
1 has a bare wire and a cord end terminal at the other end, which are connected to a door status sensor
and a cable terminal block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has a cord end
terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to the two ports
on one side of the cable terminal block.

Description
Monitoring signal cables for door status sensors are classified into different types according to
the monitoring boards to which the door status is reported. The following table lists the
monitoring signal cables for door status sensors.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

78

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Table 2-39 Types of monitoring signal cables for door status sensors
Base Station
Type

Cabinet

Monitoring Board
to Which the Door
Status Is Reported

Exterior

BTS3900A
(Ver.B)

l RFC (Ver.B)

CMUA

The exterior is shown


in Figure 2-56.

l TMC11H (Ver.B)
l IBBS200D
(Ver.B) or
IBBS200T (Ver.B)
l RFC (Ver.C)

BTS3900A
(Ver.C)

CMUE

l TMC11H (Ver.C)
l IBBS200D
(Ver.C) or
IBBS200T (Ver.C)
l RFC (Ver.D)

BTS3900A
(Ver.D)

CMUEA

l TMC11H (Ver.D)
l IBBS200D
(Ver.D) or
IBBS200T
(Ver.D)
l IBBS700D

DBS3900

IBBS700T

CMUF

l TMC11H (Ver.B)

CMUA

l IBBS200D
(Ver.B) or
IBBS200T (Ver.B)
l TMC11H (Ver.C)

CMUE

l IBBS200D
(Ver.C) or
IBBS200T (Ver.C)
l TMC11H (Ver.D)

CMUEA

l IBBS200D
(Ver.D) or
IBBS200T
(Ver.D)
l BTS3900C

OMB

HEUA

OMB (Ver.C)

HEUB

l DBS3900
l BTS3900C
(Ver.C)
l DBS3900
(Ver.C)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

79

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Base Station
Type

Cabinet

Monitoring Board
to Which the Door
Status Is Reported

BTS3900AL
(Ver.A)

l BTS3900AL
(Ver.A)

CCU

Exterior

l IBBS700D
l IBBS700T
l BTS3900A
(Ver.B)

APM30H (Ver.B)

HPMI

APM30H (Ver.C)

HPMI

APM30H (Ver.D)

PMU

The exterior is shown


in Figure 2-57.

l DBS3900
l BTS3900A
(Ver.C)
l DBS3900
l BTS3900A
(Ver.D)

The exterior is shown


in Figure 2-58.

l DBS3900

Monitoring Signal Transfer Cable for the Fan in the Front Door
A monitoring signal transfer cable for the fan in the front door feeds power into the fan in the
front door of the APM30H or TMC11H. It also transmits fan monitoring signals to a monitoring
board in the cabinet.

Cable Type
The following table lists the types of monitoring boards to which the monitoring signals are
reported. Monitoring signal cables vary according to the boards.
Table 2-40 Cable type

Issue 03 (2013-01-15)

Cable

Cabinet

Monitoring Board to
Which the
Monitoring Signals
Are Reported

Exterior

Monitoring
signal
transfer
cable for
the fan in
the front
door

APM30H (Ver.B) or
TMC11H (Ver.B)

CMUA

APM30H (Ver.C) or
TMC11H (Ver.C)

CMUE

The exterior is shown by


illustration 1 in the
following figure.

APM30H (Ver.D) or
TMC11H (Ver.D)

CMUEA

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

The exterior is shown by


illustration 2 in the
following figure.

80

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Exterior
The following figure shows the exteriors of monitoring signal transfer cables for fans in the front
doors.
Figure 2-59 Exteriors of monitoring signal transfer cables for fans in the front doors

(1) 4-pin connector

(2) Interconnection terminal

Description
The following table describes a monitoring signal transfer cable for the fan in the front door.
Table 2-41 Monitoring signal transfer cable for the fan in the front door
Wire

X1 End

X2 End

Color

W1

X1.1

X2.1

Black

W2

X1.2

X2.2

Black

W3

X1.3

X2.3

Black

W4

X1.4

X2.4

Black

PMU 11A-CMUEA Monitoring Signal Cable


The PMU 11A-CMUEA monitoring signal cable connects the PMU and the CMUEA in the
FAN 02D. It transmits the RS485 signals collected by the PMU to the BBU through the CMUEA.
This monitoring signal cable is 1.1 m (3.61 ft) long.

Exterior
The following figure shows the exterior of a PMU 11A-CMUEA monitoring signal cable.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

81

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

2 APM30H Cabinet

Figure 2-60 Exterior of a PMU 11A-CMUEA monitoring signal cable

(1) RJ45 connector

Description
The following table describes a PMU 11A-CMUEA monitoring signal cable.
Table 2-42 PMU 11A-CMUEA monitoring signal cable

Issue 03 (2013-01-15)

X1 End

X2 End

Wire Type

X1.1

X2.1

Twisted pair

X1.2

X2.2

X1.3

X2.3

X1.6

X2.6

X1.4

X2.4

X1.5

X2.5

X1.7

X2.7

X1.8

X2.8

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Twisted pair

Twisted pair

Twisted pair

82

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

TMC11H Cabinet

About This Chapter


This chapter describes the TMC11H cabinet exterior, engineering specifications, application
scenarios, as well as boards, modules, and cables in the TMC11H cabinet.
3.1 Cabinet Exterior
The transmission cabinet of 11 U high with heat exchanger (TMC11H) is used for Huawei
wireless products outdoors. It supplies DC power to the distributed or separated macro base
station in outdoor scenarios.
3.2 Cabinet Engineering Specifications
This section describes the engineering specifications of the TMC11H, including the electrical
specifications, equipment specifications, surge protection specifications, and environment
specifications.
3.3 Cabinet Application Scenarios
The TMC11H can apply to a distributed base station or a separated macro base station.
3.4 Cabinet Interior
This section describes the components and boards in the TMC11H. If a filler module or an AC
heater is not configured, 11 U space is provided for customer equipment.
3.5 TMC11H Components
This section describes the mandatory and optional components in a TMC11H.
3.6 TMC11H Cables
The TMC11H cables consist of the power cables, equipotential cables, PGND cables, and signal
cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

83

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

3.1 Cabinet Exterior


The transmission cabinet of 11 U high with heat exchanger (TMC11H) is used for Huawei
wireless products outdoors. It supplies DC power to the distributed or separated macro base
station in outdoor scenarios.
The exterior of the TMC11H is the same as that of the APM30H, but their inner modules are
different. The following figure shows the exterior of the TMC11H.
Figure 3-1 Exterior of the TMC11H

3.2 Cabinet Engineering Specifications


This section describes the engineering specifications of the TMC11H, including the electrical
specifications, equipment specifications, surge protection specifications, and environment
specifications.

Electrical Specifications
The following table lists the electrical specifications of the TMC11H.
Table 3-1 Electrical specifications
Parameter
Characteristi
cs of DC
input

Issue 03 (2013-01-15)

Specifications
Input voltage
range

-38.4 V DC to -57 V DC

Typical input
voltage

-48 V DC

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

84

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Parameter

3 TMC11H Cabinet

Specifications
Maximum input
current

The maximum input current depends on the application


scenario.
l In a distributed base station: 160 A
l In a separated macro base station: 30 A (When the
TMC11H is configured together with the APM30H,
the APM30H supplies power to the TMC11H.)

Characteristi
cs of DC
output

Input mode

-48 V DC power input, supporting the one-hole M6 OT


terminal

DC distribution

Ten -48 V DC outputs: LOAD0 to LOAD9, used to


supply power to the customer equipment

Typical output
voltage

-48 V DC

Protection

Providing overcurrent protection and short-circuit


protection for the DC power

Heat consumption of the cabinet

1500 W (heat dissipation capability at the ambient


temperature of 50oC or 122oF)

Equipment Specifications
The following table lists the equipment specifications of the TMC11H.
Table 3-2 Equipment specifications
Parameter

Specifications

Remarks

Dimensions (H x W
x D)

Cabinet (without the base):


700 mm x 600 mm x 480 mm
(27.56 in. x 23.62 in. x 18.90
in.)

The TMC11H and APM30H have the


same exterior and base.

Base: 200 mm x 600 mm x


434 mm (7.87 in. x 23.62 in.
x 17.09 in.)

Issue 03 (2013-01-15)

Space for the


customer equipment
(H x W x D)

11 U x 19 in. x 380 mm

The depth includes 100 mm (3.94 in.)


in front of the columns and 280 mm
(11.02 in.) between the columns and
the rear of the cabinet.

Cabling and
maintenance space
at the front

70 mm (2.76 in.)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

85

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Parameter

Specifications

Remarks

Cabinet weight

47 kg (103.64 lb)

Total weight of the equipment


l Including the cabinet frame, outer
air circulation assembly (heat
dissipation core and outer air
circulation fan), inner air
circulation fan assembly, DCDU,
and cables
l Excluding the customer
transmission equipment

It can be installed on the


ground, pole, or wall. It can
also be installed on an RFC,
IBBS200D, or IBBS200T in
stack mode.

Method of
installation

In stack mode, the TMC11H must be


installed on the top of the RFC,
IBBS200D, or IBBS200T.

Surge Protection Specifications


The following table lists the surge protection specifications of the TMC11H.
Table 3-3 Surge protection specifications
Item

Specifications

Surge protection for DC


input ports

l In differential mode (8/20 us): 3 kA

Surge protection for DC


output ports

l In differential mode (8/20 us): 10 kA

l In common mode (8/20 us): 5 kA

l In common mode (8/20 us): 20 kA


The DC output corresponds to the secondary load.
NOTE
The surge protection capacity of the shield layer in an RRU power cable
is 40 kA.

Environment Specifications
The TMC11H can be used outdoors. The following table lists the environment specifications of
the TMC11H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

86

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Table 3-4 Environment specifications


Paramete
r

Specifications

Remarks

Operating
temperatur
e

-40oC to +50oC (-40oF to


+122oF)

A heater is required when the temperature is


lower than -20oC (-4oF). A sun shield is
required when the temperature is higher than
50oC (122oF).
NOTE
The temperature at which the heater is required is
specified as the local average lowest temperature of
each day in the coldest month of the year.

Issue 03 (2013-01-15)

Relative
humidity

5% RH to 100% RH

Altitude

-60 m to +4000 m (-196.85 ft


to +13123.2 ft)

From the altitude of 1800 m (5905.44 ft), the


maximum operating temperature drops by 1oC
(33.8oF) each time the altitude increases by 220
m (721.78 ft).

Wind
speed

67 m/s

Storage
temperatur
e

-40oC to +70oC (-40oF to


+158oF)

Dustproof
and
waterproof

IP55

Noise

When the heat consumption


of the cabinet is equal to or
less than 700 W, the noise is
equal to or less than 61 dBA
at the temperature of 25oC
(77oF) and equal to or less
than 67 dBA at the
temperature of 45oC (113oF).

Meeting the ETS 300 753 4.1E standard (rural


area)

When the heat consumption


of the cabinet is equal to 1500
W or between 700 W and
1500 W, the noise is equal to
or less than 66 dBA at the
temperature of 25oC (77oF)
and equal to or less than 76
dBA at the temperature of
45oC (113oF).

Meeting the ETS 300 753 4.1E standard (urban


area)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

87

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

3.3 Cabinet Application Scenarios


The TMC11H can apply to a distributed base station or a separated macro base station.

Distributed Base Stations Configured with a TMC11H


The following figure shows the distributed base station configured with a TMC11H.
Figure 3-2 Distributed base station configured with a TMC11H

In a distributed base station, a TMC11H is configured as follows:


l

Supplied with -48 V DC power.

Combined with RRUs.

Configured with a DCDU-12B, which distributes power into RRUs and the BBU, fan
assembly, and transmission equipment in the TMC11H.

Separated Macro Base Stations Configured with a TMC11H


The following figure shows the separated macro base station configured with a TMC11H.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

88

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-3 Separated macro base station configured with a TMC11H

In a separated macro base station, a TMC11H is configured as follows:


l

Supplied with -48 V DC power.

Stacked on the RFC.

External -48 V DC power is supplied to the DC junction box on the left wall of the RFC
interior, and then distributed to the DCDUs in the RFC and TMC11H.

3.4 Cabinet Interior


This section describes the components and boards in the TMC11H. If a filler module or an AC
heater is not configured, 11 U space is provided for customer equipment.
The following figure shows the interior of the TMC11H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

89

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-4 Interior of the TMC11H

The following table describes the components in the TMC11H.


Table 3-5 Components in the TMC11H
N
o.

Compon
ent

Outer air
circulatio
n
assembly

Ma
nda
tory

The assembly is installed on the front door of the cabinet,


dissipating heat from the cabinet.

Junction
box

Ma
nda
tory

The junction box converts one AC input to four AC outputs


and is used in the scenario where a service outlet unit (SOU)
and multiple heating films or heaters are configured.

Issue 03 (2013-01-15)

Op
tio
nal
or
Ma
nd
ato
ry

Ma
xi
mu
m
Qu
ant
ity
in
a
Sin
gle
Ca
bin
et

Remarks

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

90

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

N
o.

Compon
ent

Op
tio
nal
or
Ma
nd
ato
ry

Ma
FAN 02D nda
tory

Ma
xi
mu
m
Qu
ant
ity
in
a
Sin
gle
Ca
bin
et
1

The fan assembly is configured with fans and central


monitoring unit type EA (CMUEA), dissipating heat from the
cabinet.
l To provide protection for trunk signals, a signal lightning
protection unit (SLPU) is mandatory and installed in the
top 1 U space of the cabinet. It is configured with the
universal E1/T1 lightning protection unit (UELP) or
universal FE lightning protection unit (UFLP).

Door
status
sensor

Ma
nda
tory

The door status sensor monitors the status (open or closed) of


the cabinet door.

ELU

Ma
nda
tory

The electronic label unit (ELU) reports the cabinet type


automatically to facilitate troubleshooting.

DCDU-1
2B or
DCDU-1
2C

Ma
nda
tory

The direct current distribution unit-12B (DCDU-12B) or


direct current distribution unit-12C (DCDU-12C) in the
TMC11H distributes DC power to all the components in the
TMC11H. A DCDU-12B or DCDU-12C is 1 U high. The
DCDU varies with the installation scenarios.

Remarks

Ma
nda
tory

SLPU

3 TMC11H Cabinet

l To provide protection for monitoring signals, an SLPU is


optional and installed in the 1 U space below the BBU. It
is configured with two universal signal lightning
protection unit 2 (USLP2) boards.

A maximum of two BBU3900s can be configured in a


TMC11H.
BBU390
0

Opt
ion
al

l The BBU3900 provides physical ports for communication


between the BBU3900 and the BSC or RNC, and enables
interaction between the base station and the BSC or RNC.
l The BBU3900 provides CPRI ports for communication
between the BBU and RF modules.
l The BBU3900 processes uplink and downlink data.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

91

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

N
o.

Compon
ent

10

Op
tio
nal
or
Ma
nd
ato
ry

Ma
xi
mu
m
Qu
ant
ity
in
a
Sin
gle
Ca
bin
et

3 TMC11H Cabinet

Remarks

EMUA

Opt
ion
al

The environment monitoring unit type A (EMUA) monitors


environment of the equipment.

Filler
module

Opt
ion
al

A filler module is a plastic component with a height of 1 U in


the cabinet, preventing the heat reflux in the empty space
below the BBU.

AC
heater

Opt
ion
al

The AC heater ensures that components in the cabinet work


within the acceptable temperature range when the
surrounding temperature is low. It can be preferentially
installed in the 1 U space at the bottom of the cabinet.

11

3.5 TMC11H Components


This section describes the mandatory and optional components in a TMC11H.

3.5.1 DCDU-12B
A direct current distribution unit-12B (DCDU-12B) is 1 U high and provides -48 V DC power
for other components.

Exterior
The following figure shows the front and rear of the DCDU-12B.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

92

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-5 Front and rear of the DCDU-12B

(1) Equipotential ground points

(2) Ground points

NOTE

A DCDU-12B uses the equipotential connection point and ground point in the following scenarios:
l Scenario 1: The DCDU-12B is installed on an open rack. In this scenario, an equipotential cable
connects the equipotential ground point near the mounting ear on the DCDU-12B to the ground bar on
the open rack.
l Scenario 2: The DCDU-12B is installed on a wall as a standalone power distribution device. In this
scenario, the ground point at the rear of the DCDU-12B is connected to the ground bar in the equipment
room.

Function
The DCDU-12B provides ten -48 V DC outputs using the same fuse configurations to meet the
power distribution requirements of indoor and outdoor macro base stations, micro base stations,
and distributed base stations.

Port
The following figure shows the ports on the DCDU-12B panel.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

93

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-6 Ports on the DCDU-12B panel

The following table describes the ports on the DCDU-12B panel.


Table 3-6 Ports on the DCDU-12B panel
N
o.

Port

Silkscreen

Matched Terminal
and Cable

Description

(1)

DC input
terminals

NEG(-)

Two one-hole OT
terminals (M6). If
one group of power
cables are used, the
maximum crosssectional area of each
power cable is 35
mm2 (0.054 in.2). If
two groups of power
cables are used, the
maximum crosssectional area of each
power cable is 25
mm2 (0.039 in.2).

It is a negative power input


wiring terminal.

RTN(+)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

It is a positive power input


wiring terminal.

94

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

N
o.

Port

Silkscreen

Matched Terminal
and Cable

Description

(2)

Fuse
blocks

LOAD0 to
LOAD9

The fuse blocks control the


LOAD0 to LOAD9 ports, and
therefore control the power
supplies to the BBU, fan
assemblies, and transmission
equipment.
The indicator on the fuse block
indicates the status of the fuse.
l When the indicator is steady
on, the fuse is faulty and
needs to be replaced.
l When the indicator is steady
off, the fuse is working
properly.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

95

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

N
o.

Port

Silkscreen

Matched Terminal
and Cable

Description

(3)

DC
output
ports

LOAD0 to
LOAD9

l Figure 3-7 shows For the specifications of the DC


output, see Table 3-7.
an EPC5
connector, which
applies to any of
the LOAD0 to
LOAD5 ports.
The maximum
cross-sectional
area of the cable
supported is 6
mm2 (0.009 in.2)
to 10 mm2 (0.016
in.2).
l Figure 3-8 shows
an EPC4 or EPC6
connector, which
applies to any of
the LOAD6 to
LOAD9 ports.
The maximum
cross-sectional
area of the cable
supported is 3.3
mm2 (0.005 in.2)
to 4 mm2 (0.006
in.2).
NOTE
Figure 3-8 shows an
EPC4 or EPC6
connector. An EPC4
connector must be
connected to a cable
onsite, whereas an
EPC6 connector has
been connected to a
cable before delivery.
An EPC5 connector
must also be
connected to a cable
onsite.

NOTE

A fuse block and a DC output port are jointly called a fuse terminal block.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

96

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-7 Exterior of an EPC5 connector

Figure 3-8 Exterior of an EPC4 or EPC6 connector

The following table describes the power distribution of the DC output ports on a DCDU-12B.
Table 3-7 Power distribution of the DC output ports on a DCDU-12B
Base Station Type

Application
Scenario

DC Output
Port

PowerConsumin
g Device

Fuse
Specif
ication

DBS3900

l DBS3900
configured with a
power cabinet
TMC11H (Ver.D)
l DBS3900 where the
BBU is installed on
a wall, 19-inch rack,
or IMB03

LOAD0 to
LOAD5

RRU

10x30
A

LOAD6 and
LOAD7

Transmissio
n equipment
or BBU

LOAD8

Transmissio
n equipment

LOAD9

FAN 02D

BTS3900AL (Ver.A)
configured with RFUs
and RRUs

LOAD0 to
LOAD5

RRU 0 to
RRU 5

LOAD6 to
LOAD9

Reserved

l BTS3900A (Ver.D)
configured with an
RFC (Ver.D)
cabinet and

LOAD0 to
LOAD8

RRU 0 to
RRU 9

BTS3900AL (Ver.A)

l BTS3900A (Ver.D)
l BTS3900 (Ver.D)
l BTS3900L (Ver.D)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

10x30
A

10x30
A

97

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base Station Type

3 TMC11H Cabinet

Application
Scenario

DC Output
Port

PowerConsumin
g Device

configured with
RFUs and RRUs
l BTS3900 (Ver.D)
configured with
RFUs and RRUs
l BTS3900L (Ver.D)
configured with
RFUs and RRUs

LOAD9

Reserved

Fuse
Specif
ication

Technical Specifications
The following table lists the technical specifications of a DCDU-12B.
Table 3-8 Technical specifications of a DCDU-12B
Parameter

Specifications

Dimensions (H x W x D)

A DCDU-12B is 1 U high and can be installed


in a 19-inch cabinet or rack. Its dimensions
are as follows:
l 42 mm x 442 mm x 65 mm (1.65 in. x 17.4
in. x 2.56 in.) (without mounting ears)
l 42 mm x 482.6 mm x 65 mm (1.65 in. x
19 in. x 2.56 in.) (with mounting ears)

Surge protection specifications

-48 V DC power port, 10 kA (8/20 s)


differential mode
-48 V DC power port, 20 kA (8/20 s)
common mode

3.5.2 DCDU-12C
A direct current distribution unit-12C (DCDU-12C) is 1 U high and provides -48 V DC power
for other components.

Exterior
The following figure shows the front and rear of the DCDU-12C.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

98

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-9 Front and rear of the DCDU-12C

(1) Equipotential ground points

(2) Ground points

NOTE

The DCDU-12C has no equipotential connection point and ground point.

Function
The DCDU-12C provides ten -48 V DC outputs using same fuse configurations to meet the
power distribution requirements of distributed and outdoor macro base stations.

Port
The following table describes the ports and terminals on a DCDU-12C panel.
Figure 3-10 Ports on the DCDU-12C panel

The following table describes the ports on the DCDU-12C panel.


Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

99

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Table 3-9 Ports on the DCDU-12C panel


N
o.

Port

Silkscreen

Matched Terminal
and Cable

Description

(1)

DC input
terminals

NEG(-)

Two one-hole OT
terminals (M6). The
cross-sectional area
of the cable is 16
mm2 (0.025 in.2) by
default.

It is a negative power input


wiring terminal.

The fuse blocks control the


LOAD0 to LOAD9 ports, and
therefore control the power
supplies to the BBU, fan
assemblies, and transmission
equipment.

RTN(+)

(2)

Fuse
blocks

LOAD0 to
LOAD9

It is a positive power input


wiring terminal.

The indicator on the fuse block


indicates the status of the fuse.
l When the indicator is steady
on, the fuse is faulty and
needs to be replaced.
l When the indicator is steady
off, the fuse is working
properly.
(3)

DC
output
ports

LOAD0 to
LOAD9

Figure 3-11 shows


For the specifications of the DC
an EPC4 or EPC6
output, see Table 3-10.
connector, which
applies to any of the
LOAD0 to LOAD9
ports. The maximum
cross-sectional area
of the cable
supported is 3.3
mm2 (0.005 in.2) to 4
mm2 (0.006 in.2).

NOTE

A fuse block and a DC output port are jointly called a fuse terminal block.

Figure 3-11 Exterior of an EPC4 or EPC6 connector

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

100

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

The following table describes the power distribution of the DC output ports on a DCDU-12C.
Table 3-10 Power distribution of the DC output ports on a DCDU-12C
Base
Station
Type

Application Scenario

DC Output
Port

PowerConsuming
Device

Fuse
Specif
ication

l BTS3900
A (Ver.D)
l DBS3900

l BTS3900A (Ver.D)
configured with a power
cabinet TMC11H (Ver.D)
l BTS3900A (Ver.D)
configured with a
transmission cabinet
TMC11H (Ver.D)
l DBS3900 configured with
an APM30H (Ver.D) and a
transmission cabinet
TMC11H (Ver.D)

LOAD0 to
LOAD5 and
LOAD8

Transmission
equipment

10x30
A

LOAD6 and
LOAD7

Transmission
equipment or
BBU

LOAD9

FAN 02D

Equipment compartment of the


BTS3900AL (Ver.A) cabinet

LOAD0

CCU

LOAD1

Reserved

LOAD2 and
LOAD3

Transmission
equipment

LOAD4

Battery
cabinet

LOAD5 to
LOAD8

BBU

LOAD9

Heat
exchanger

LOAD0 to
LOAD8

RFUs

LOAD9

FAU

BTS3900AL
(Ver.A)

RF compartment of the
BTS3900AL (Ver.A) cabinet

10x30
A

10x30
A

Technical Specifications
The following table lists the technical specifications of a DCDU-12C.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

101

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Table 3-11 Technical specifications of a DCDU-12C


Parameter

Specifications

Dimensions (H x W x D)

The DCDU-12C is 1 U (44.45 mm or 1.75 in.)


high and can be installed in a 19-inch cabinet
or rack. Its dimensions are as follows:
l 42 mm x 442 mm x 65 mm (1.65 in. x 17.4
in. x 2.56 in.) (without mounting ears)
l 42 mm x 482.6 mm x 65 mm (1.65 in. x
19 in. x 2.56 in.) (with mounting ears)
-48 V DC power port, 10 kA (8/20 s)
differential mode

Surge protection specifications

-48 V DC power port, 20 kA (8/20 s)


common mode

3.5.3 FAN 02D


A FAN 02C dissipates heat and detects temperature for an APM30H (Ver.D) or TMC11H
(Ver.D).

Exterior
A FAN 02D consists of the fan subrack, fans, and CMUEA. The following figure shows the
exterior of a FAN 02D.
Figure 3-12 Exterior of a FAN 02D

(1) Fan subrack

(2) Fans

(3) CMUEA

For details about the ports and indicators on the CMUEA, see CMUEA.

3.5.4 Filler Module


A filler module is a standard plastic component, which prevents heat reflux in the empty space
below the BBU and improves the heat dissipation in the cabinet. Filler modules are installed in
the customer space of an APM30H or TMC11H.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

102

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Exterior
A filler module is 1 U high. The following figure shows the exterior of a filler module.
Figure 3-13 Exterior of a filler module

Function
A filler module is installed in the customer space below the BBU to prevent heat reflux in the
empty space below the BBU.
NOTE

In an APM30H or TMC11H, the filler module is configured in the customer space by default. Before
installing other modules, first remove the filler module. For details about removing a filler module, see
chapter "Installing Optional Modules and Cables" in the "Installation Guide".

3.5.5 Junction Box


The junction box is configured in the BTS3900AL, APM30H, TMC11H, IBBS700D, or
IBBS700T cabinet. When a heater or a heating film is configured, the junction box feeds power
to the heater or the heating film.

Exterior
A junction box is installed on the left inner side of the APM30H, TMC11H, IBBS700D, or
IBBS700T. In the BTS3900AL, the junction box is installed on the right inner side of the cabinet.
The following figure shows the position and exterior of the junction box in the APM30H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

103

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-14 Exterior of the junction box

Functions
The junction box used in the BTS3900AL, APM30H, TMC11H, IBBS700D and IBBS700T
performs the following functions:
l

The PDU05A-01 feeds power to the junction box in the BTS3900AL. The power is divided
into four AC power outputs, which are then provided for the heater in the cabinet.

The EPU subrack feeds power into the junction box in the APM30H. The power is divided
into four AC power outputs, which are then provided for the heater in the cabinet or heating
film in the IBBS200D.

The junction box in the APM30H feeds power into the junction box in the TMC11H. The
power is divided into four AC power outputs, which are then provided for the heater or
service outlet unit (SOU) in the cabinet.

The junction box in the primary cabinet (BTS3900A, BTS3900AL, or TP48600A-H17B1)


feeds power into the junction box in the IBBS700D or IBBS700T. The power is divided
into four AC power outputs, which are then provided for the heater in the cabinet.

Interior
The following figure shows the interior of an AC junction box.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

104

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-15 Interior of an AC junction box

(1) Four AC output L wiring


terminals

(2) Four AC output N wiring


terminals

(3) Four AC output PE wiring


terminals

(4) Cable holes

(5) AC input N wiring terminal

(6) AC input L wiring terminal

3.5.6 ELU
An electronic label unit (ELU) reports the cabinet type automatically to facilitate
troubleshooting.

Exterior
The following figure shows the exterior of an ELU.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

105

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-16 Exterior of an ELU

(1) Shell

(2) RJ45 port

NOTE

The ELU in a BTS3900 or BTS3900L has no shell.

The board collecting information from the ELU varies according to the cabinet, as listed in the
following table.
Table 3-12 Monitoring boards to which an ELU reports information

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Board Collecting
Information from
the ELU

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B) and BTS3900L (Ver.B)

FMUC

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C) and BTS3900L (Ver.C)

FMUE

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D) and BTS3900L (Ver.D)

FMUEA

BTS3900A
(Ver.B)

APM30H (Ver.B), TMC11H (Ver.B), RFC


(Ver.B), IBBS200D (Ver.B), and IBBS200T
(Ver.B)

CMUA

BTS3900A
(Ver.C)

APM30H (Ver.C), TMC11H (Ver.C), RFC


(Ver.C), IBBS200D (Ver.C), and IBBS200T
(Ver.C)

CMUE

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

106

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base Station
Type

Cabinet

Board Collecting
Information from
the ELU

BTS3900A
(Ver.D)

APM30H (Ver.D), TMC11H(Ver.D), RFC


(Ver.D), IBBS200D(Ver.D), IBBS200T
(Ver.D), and IBBS700D

CMUEA

IBBS700T

CMUF

BTS3900C
(Ver.C)

OMB (Ver.C)

HEUB

BTS3900AL
(Ver.A)

BTS3900AL (Ver.A), IBBS700D, IBBS700T

CCU

Installation Position
Positions of ELUs vary in different cabinets. The following figure shows their positions.
Figure 3-17 Position of the ELU in a BTS3900 cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

107

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-18 Position of the ELU in a BTS3900L cabinet

Figure 3-19 Position of the ELU in an APM30H or IBBS200D cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

108

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

NOTE

An ELU is located on the right inner wall of the APM30H, TMC11H, or RFC, or on the left inner wall of
the IBBS200D or IBBS200T. The preceding figure shows an APM30H and an IBBS200D as an example.

Figure 3-20 Position of the ELU in an OMB

Figure 3-21 Position of the ELU in a BTS3900AL cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

109

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-22 Position of the ELU in a IBBS700D cabinet

NOTE

In the IBBS700D, when the cabinet is configured with a CCU, the ELU is above the CCU. When the cabinet
is not configured with a CCU, the ELU is on the right of the CMUEA.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

110

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-23 Position of the ELU in a IBBS700T cabinet

NOTE

In the IBBS700T, when the cabinet is configured with a CCU, the ELU is above the CCU. When the cabinet
is not configured with a CCU, the ELU is on the left of the CMUF.

3.5.7 Door Status Sensor


A door status sensor reports the status (open or closed) of a door. It is installed in any of the
following cabinets: BTS3900AL, OMB, OMB (Ver.C), APM30H, RFC, TMC11H, IBBS200D,
IBBS200T, IBBS700D, and IBBS700T.

Exterior
A door status sensor consists of a magnet and a switch. The following figures show the exteriors
of them.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

111

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-24 Exterior of the magnet of a door status sensor

(1) Magnetic shell

(2) Magnet

The following figure shows the exterior of the switch of a door status sensor.
Figure 3-25 Exterior of the switch of a door status sensor

Installation Position
Positions of door status sensors vary in different cabinets. The following figure shows their
positions.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

112

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

NOTE

l A door status sensor is installed at the same position in the BTS3900AL (Ver.A), IBBS700D, and
IBBS700T. Figure 3-26 uses the BTS3900AL (Ver.A) as an example.
l A door status sensor is installed at the same position in the OMB and OMB (Ver.C). Figure 3-27 uses
the OMB (Ver.C) as an example.
l A door status sensor is installed at the same position in the following cabinets: APM30H (Ver.B),
APM30H (Ver.C), APM30H (Ver.D), RFC (Ver.B), RFC (Ver.C), RFC (Ver.D), TMC11H (Ver.B),
TMC11H (Ver.C), TMC11H (Ver.D), IBBS200D (Ver.B), IBBS200D (Ver.C), IBBS200D (Ver.D),
IBBS200T (Ver.B), IBBS200T (Ver.C), and IBBS200T (Ver.D). Figure 3-28 uses the APM30H
(Ver.D) as an example.

Figure 3-26 Position of a door status sensor in the BTS3900AL (Ver.A)

Figure 3-27 Position of a door status sensor in the OMB (Ver.C)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

113

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-28 Position of a door status sensor in the APM30H (Ver.D)

3.5.8 AC Heater
An AC heater is optionally installed in the customer space in an APM30H or TMC11H. It ensures
that the customer equipment in a cabinet works within the acceptable temperature range.

Exterior
The following figure shows the exterior of an AC heater.
Figure 3-29 Exterior of an AC heater

Technical Specifications
The following table lists the technical specifications of an AC heater.
Table 3-13 Technical specifications of an AC heater

Issue 03 (2013-01-15)

Counter

Specification

Temperature range in the cabinet when the


AC heater starts working

< 1oC (6oC)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

114

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Counter

Specification

Temperature range in the cabinet when the


AC heater stops working

> 15oC (3oC)

Rated heating power

330 W

3.5.9 SOU
A service outlet unit (SOU) transfers AC power to the customer equipment. An SOU is optionally
installed in the customer space in an APM30H or TMC11H.

Exterior
An SOU is 1 U high. The following figure shows the exterior of an SOU.
Figure 3-30 Exterior of an SOU

(1) Input power port

(2) Breaker

(3) Socket (European standard)

An SOU applies to the four types of sockets meeting the following standards: North American
standard, European standard, Universal standard, and British standard. The following figure
shows the exteriors of the four types of sockets.
Figure 3-31 Exteriors of different types of sockets

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

115

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Technical Specifications
The following table lists the technical specifications of an SOU.
Table 3-14 Technical specifications of an SOU
Counter

Specification

Dimensions (H x W x D)

482.6 mm x 91 mm x 55 mm (7.87 in. x 23.62


in. x 17.09 in.)

Weight

1.5 kg (3.31 lb)

Input voltage range

200 V AC to 240 V AC

Maximum input current

10 A

Output voltage range

200 V AC to 240 V AC

Maximum output current

10 A

Frequency band

50 Hz or 60 Hz

Operating temperature

-40oC to +55oC

Altitude

4,000m
NOTE
Above the altitude of 3000 m (9842.52 ft), the
maximum operating temperature drops by 1oC
(33.8oF) as the altitude increases by 100 m (328.08
ft).

Protection class

IP20

3.6 TMC11H Cables


The TMC11H cables consist of the power cables, equipotential cables, PGND cables, and signal
cables.

3.6.1 Cable List


TMC11H cables mainly consist of the equipotential cables, power cables, and signal cables.

Equipotential Cables and Power Cables


The following table describes the equipotential cables and power cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

116

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Table 3-15 Equipotential cables and power cables


Classi
ficati
on

Cable

Cables
to be
install
ed
onsite

Cables
install
ed
before
deliver
y

Issue 03 (2013-01-15)

One End

The Other End

Connector

Installation
Position

Connector

Installation
Position

DCDU-12C
Power Cable
(AC scenario)

EPC4 or
EPC6
connector

LOAD7 port
on the EPU

OT terminal

RTN(+) and
NEG(-)
terminals on
the INPUT
terminal block
on the
DCDU-12C

Power Cable
for an AC
Junction Box
(in the
TMC11H)

OT terminal

L3 and N3
terminals on
the AC
junction box
in the
APM30H

OT terminal

L and N
terminals on
the AC
junction box in
the TMC11H

Power Cable
for an AC
Heater (-48 V
DC scenario)

C13
connector

Input power
port on the AC
heater

Depending
on external
power
equipment

External
power
equipment

2.7.4
Equipotential
Cable

OT terminal

Ground bar in
the upper
cabinet

OT terminal

Ground bar in
the lower
cabinet

DCDU-12B
Power Cable

OT terminal

RTN(+) and
NEG(-)
terminals on
the INPUT
terminal block
on the
DCDU-12B

Depending
on external
power
equipment

External
power
equipment

FAN 02D
Power Cable

EPC4 or
EPC6
connector

LOAD9 port
on the
DCDU-12C

3V3
connector

PWR port on
the fan
assembly in
the TMC11H

Power Cable
for an AC
Heater

OT terminal

L0 and N0
terminals on
the AC
junction box
in the
TMC11H and
the cabinet
ground bar

C13
connector

Input power
port on the AC
heater

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

117

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Classi
ficati
on

Cable

3 TMC11H Cabinet

One End

DCDU-12B
Power Cable
(-48 V DC
scenario)

The Other End

Connector

Installation
Position

Connector

Installation
Position

OT terminal

DC junction
box in the
RFC

OT terminal

RTN(+) and
NEG(-)
terminals on
the INPUT
terminal block
on the
DCDU-12B

NOTE

The connection of power cables for optional components depends on the delivery mode. Table 3-15
describes the power cables in a macro base station.

Signal Cables
The following table describes the signal cables.
Table 3-16 Signal cables

Issue 03 (2013-01-15)

Classi
ficati
on

Cable

Cables
to be
install
ed
onsite
Cables
install
ed
before
deliver
y

One End

The Other End

Connecto
r

Installation
Position

Connect
or

Installation
Position

ELU Signal
Cable

RJ45
connector

ELU

RJ45
connector

ELU port on the


CMUEA

Monitoring
Signal
Cable for
the Door
Status
Sensor

Bare wire

GATE port on the


CMUEA

Bare wire

Door status sensor

Monitoring
Signal
Transfer
Cable for
the Fan in
the Front
Door

Interconne
ction
terminal

Interconnection
terminal on the
front door of the
TMC11H

4-pin
connector

FAN_EXT port on
the CMUEA

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

118

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

3.6.2 Cable Connections


This section describes the principles for connecting power cables and signal cables in the
TMC11H.

Power Cable Connections


This section describes the power cable connections in the TMC11H.
The following figure shows the power cable connections in the TMC11H.
Figure 3-32 Power cable connections in the TMC11H

(1) FAN 02D Power Cable (2) Power Cable for an AC Heater (3) DCDU-12B Power Cable or DCDU-12C
Power Cable

Monitoring Signal Cable Connections


This section provides reference for onsite installation of monitoring signal cables.
Figure 3-33 shows the monitoring signal cable connections in the TMC11H.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

119

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-33 Monitoring signal cable connections in the TMC11H

(1) Monitoring signal cable for the fans on the front


door

(2) Monitoring signal transfer cable for the fans on the


front door

(3) ELU signal cable

(4) Monitoring signal cable for the door status sensor

3.6.3 PGND Cable


PGND cables ensure that cabinets and internal components are properly grounded and that base
stations run properly. PGND cables include classified into PGND cables for cabinets and PGND
cables for components.

Exterior
The following figure shows the exterior of a PGND cable.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

120

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-34 Exterior of a PGND cable

(1) One-hole OT terminal

(2) Two-hole OT terminal

NOTE

In most cases, the PGND cable is a yellow and green colored cable. When 110 V dual-live-wire power is
supplied for BTS3900A (Ver.C) and BTS3900A (Ver.D) cabinets, the PGND cables are green.

Description
The cross-sectional areas and maximum lengths of PGND cables vary according to the types of
cabinets. Table 3-17 and Table 3-18 describe PGND cables.
Table 3-17 PGND cables for cabinets

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B) 15 m (49.21


and BTS3900L
ft)
(Ver.B)

25 mm2
(0.039
in.2)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

One-hole
OT
terminal
(M8)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

121

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Issue 03 (2013-01-15)

3 TMC11H Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900A
(Ver.B)

RFC (Ver.B)

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.C)

RFC (Ver.C)

8 m (26.25
ft)

25 mm2
(0.039
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.D)

RFC (Ver.D)

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.D)

IBBS700D and
IBBS700T

5 m (16.4 ft)

35 mm2
(0.054
in.2)

The cable
has a onehole OT
terminal
(M6) on
the
cabinet
side and a
one-hole
OT
terminal
(M8) on
the
ground
bar side.

The exterior
is shown by
illustration
1 in the
preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

122

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900AL
(Ver.A)

BTS3900AL
(Ver.A)

8 m (26.25
ft)

35 mm2
(0.054
in.2)

Select
one of the
followin
g
specificat
ions
based on
the onsite
situation:

The exterior
is shown by
illustration
2 or 3 in the
preceding
figure.

l The
cable
has a
twohole
OT
termi
nal
(M6)
at
each
end,
and
the
distan
ce
betwe
en the
two
holes
of
each
twohole
OT
termi
nal is
15.8
mm
(0.62
in.).
l The
cable
has a
twohole
OT
termi

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

123

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base Station
Type

Cabinet

3 TMC11H Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

nal
(M6)
on the
cabin
et side
and a
onehole
OT
termi
nal
(M6)
on the
groun
d bar
side.
The
distan
ce
betwe
en the
two
holes
of the
twohole
OT
termi
nal is
15.8
mm
(0.62
in.).
IBBS700D and
IBBS700T

Issue 03 (2013-01-15)

5 m (16.4 ft)

35 mm2
(0.054
in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

The cable
has a onehole OT
terminal
(M6) on
the
cabinet
side and a
one-hole
OT
terminal
(M8) on
the
ground
bar side.

The exterior
is shown by
illustration
1 in the
preceding
figure.

124

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900C
(Ver.C)

OMB (Ver.C)

15 m (49.21
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

DBS3900

APM30H (Ver.B)
series cabinets

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

APM30H (Ver.C)
series cabinets

8 m (26.25
ft)

25 mm2
(0.039
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

APM30H
(Ver.D) series
cabinets

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

Table 3-18 PGND cables for components

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

One-hole
OT
terminal
(M4)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

125

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900A
(Ver.B)

APM30H (Ver.B)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M4)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

IBBS200D
(Ver.B)
IBBS200T
(Ver.B)

BTS3900C
(Ver.C)

OMB (Ver.C)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M6)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

BTS3900AL
(Ver.A)

BTS3900AL

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M6)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

3.6.4 Equipotential Cable


An equipotential cable connects the PGND terminals of two cabinets. It ensures equipotential
bonding between cabinets and safe operation of base stations.

Exterior
The following figure shows the exterior of an equipotential cable.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

126

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-35 Exterior of an equipotential cable

(1) One-hole OT terminal

(2) Two-hole OT terminal

NOTE

In most cases, the equipotential cable is a green and yellow cable. When 110 V dual-live-wire power is
supplied for the cabinets used by the BTS3900A (Ver.C) or BTS3900A (Ver.D), the equipotential cable
is green.

Description
The following table describes equipotential cables.
Table 3-19 Equipotential cables
Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900
(Ver.B)

16 mm2 (0.025 in.2)

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

16 mm2 (0.025 in.2)

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 2 in the preceding
figure.

BTS3900
(Ver.C)
BTS3900
(Ver.D)
BTS3900A
(Ver.B)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

127

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900A
(Ver.C)

The cross-sectional areas of


cables vary according to the
way that cabinets are
combined.

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

l 16 mm2 (0.025 in.2) for


stacked cabinets
l 25 mm2 (0.039 in.2) for
side-by-side cabinets
BTS3900A
(Ver.D)

Issue 03 (2013-01-15)

16 mm2 (0.025 in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

128

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900AL
(Ver.A)

The cross-sectional areas of


cables vary according to the
way that cabinets are
combined.

l When
a
BTS39
00AL
AC
cabinet
is
combi
ned
with a
BTS39
00AL
DC
cabinet
or an
IBBS7
00D/
IBBS7
00T,
each
end of
the
cable
has a
twohole
OT
termin
al
(M6),
and the
distanc
e
betwee
n the
two
holes
of each
twohole
termin
al is
15.8
mm
(0.62
in.).

The exterior is shown by


illustration 2 or 3 in the
preceding figure.

l When a BTS3900AL AC
cabinet is combined with a
BTS3900AL DC cabinet
or an IBBS700D/
IBBS700T, the crosssectional area of the cable
is 35 mm2 (0.054 in.2)
l When a BTS3900AL AC
cabinet is combined with a
TMC11H (Ver.C), the
cross-sectional area of the
cable is 25 mm2 (0.039in.
2).

l When
a

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

129

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Cross-Sectional Area

3 TMC11H Cabinet

Connect
or

Exterior

BTS39
00AL
AC
cabinet
is
combi
ned
with a
TMC1
1H
(Ver.C
), the
cable
has a
twohole
OT
termin
al
(M6)
on the
BTS39
00AL
AC
cabinet
side
and a
onehole
OT
termin
al
(M6)
on the
TMC1
1H
(Ver.C
) side.
The
distanc
e
betwee
n the
two
holes
of each
twohole

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

130

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Cross-Sectional Area

3 TMC11H Cabinet

Connect
or

Exterior

termin
al is
15.8
mm
(0.62
in.).

3.6.5 Power Cables


This section describes the exteriors, functions, and pin assignments of the power cables in the
TMC11H.

DCDU-12B Power Cable


A DCDU-12B power cable feeds DC power into a DCDU-12B.

Exterior
The types of DCDU-12B power cables vary according to power supply scenarios. The following
figure shows the exteriors of DCDU-12B power cables.
Figure 3-36 Exteriors of DCDU-12B power cables

(1) OT terminal (M6)

Description
The following table describes DCDU-12B power cables.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

131

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Table 3-20 DCDU-12B power cables


Base
Station
Type

Applicatio
n Scenario

Power
Equipme
nt

Cross-Sectional
Area

Maxi
mum
Leng
th

Exterior

Functi
on

BTS3900
(Ver.D)

In DC
scenarios, a
DCDU-12B
is installed
in a
BTS3900
(Ver.D)
cabinet.

External
power
equipment

10 m
(32.8
1 ft)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

In DC
scenarios, a
DCDU-12B
is installed
in a
BTS3900L
(Ver.D)
cabinet.

External
power
equipment

l One group of
cables with a
crosssectional area
of 35 mm2
(0.054 in.2) is
required when
one 160 A
upper-level
circuit breaker
is used.
l Two groups of
cables with a
crosssectional area
of 16 mm2
(0.025 in.2) are
required when
two 80 A
upper-level
circuit
breakers are
used.

When
the
base
station
is
configu
red
with
RFUs
and
RRUs,
a
DCDU
-12B
power
cable
feeds
DC
power
into the
DCDU
-12B,
and
then
the
DCDU
-12B
supplie
s the
power
to the
RRUs.

BTS3900
L (Ver.D)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.
The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.
In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

132

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base
Station
Type

Applicatio
n Scenario

Power
Equipme
nt

Cross-Sectional
Area

Maxi
mum
Leng
th

Exterior

BTS3900
A (Ver.D)

A
DCDU-12B
is installed
in an RFC
(Ver.D).

l Extern
al
power
equip
ment
in DC
scenari
os

l One group of
cables with a
crosssectional area
of 25 mm2
(0.039 in.2) in
DC scenarios

1.5 m
(4.92
ft)

The
exterior is
shown by
illustratio
n 2 in the
preceding
figure.

l EPU05
A-02
or
EPU05
A-04
in an
APM3
0H in
AC
scenari
os

DBS3900

In DC
scenarios, a
second
DCDU-12B
is installed
in a
TMC11H
(Ver.D)
configured
for the
DBS3900.

External
power
equipment

l Two groups of
cables with a
crosssectional area
of 16 mm2
(0.025 in.2) are
required when
two 80 A
upper-level
circuit
breakers are
used.

Issue 03 (2013-01-15)

In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

l One group of
cables with a
crosssectional area
of 35 mm2
(0.054 in.2) or
two groups of
cables with a
crosssectional area
of 16 mm2
(0.025 in.2) in
AC scenarios

l One group of
cables with a
crosssectional area
of 35 mm2
(0.054 in.2) is
required when
one 160 A
upper-level
circuit breaker
is used.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Functi
on

15 m
(49.2
1 ft)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.
In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

When
the
base
station
is
configu
red
with
RFUs
and
RRUs,
a
DCDU
-12B
power
cable
feeds
DC
power
into the
DCDU
-12B,
and
then

133

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Issue 03 (2013-01-15)

3 TMC11H Cabinet

Applicatio
n Scenario

Power
Equipme
nt

Cross-Sectional
Area

Maxi
mum
Leng
th

Exterior

Functi
on

In AC
scenarios
where the
DBS3900
uses the
APM30H
(Ver.D) and
is
configured
with 7 to 12
RRUs, the
DCDU-12B
is installed
in the
APM30H
(Ver.D).

EPU05A03 or
EPU05A05 in the
APM30H

One group of
cables with a
cross-sectional
area of 25 mm2
(0.039 in.2)

1.5 m
(4.92
ft)

The
exterior is
shown by
illustratio
n 2 in the
preceding
figure.

the
DCDU
-12B
supplie
s the
power
to
RFUs,
RRUs,
and
transmi
ssion
equipm
ent.

DBS3900
where the
BBU is
installed on
a wall, 19inch rack, or
IMB03.

External
power
equipment

In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

One group
of cables
with a
crosssectional
area of 25
mm2
(0.039 in.
2)

One group of
cables with a
cross-sectional
area of 16 mm2
(0.023 in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

15 m
(49.2
1 ft)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.
In most
regions,
the RTN
(+) wire is
black and
the NEG
(-) wire is
blue. In
UK, the
RTN(+)
wire is
blue and
the NEG
(-) wire is
gray.

134

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

DCDU-12C Power Cable


A DCDU-12C power cable feeds DC power into a DCDU-12C.

Exterior
The types of DCDU-12C power cables vary according to power supply scenarios. The following
figure shows the exteriors of DCDU-12C power cables.
Figure 3-37 Exteriors of DCDU-12C power cables

(1) EPC4 or EPC6 connector

(2) OT terminal (M6)

NOTE

In most regions, the RTN(+) wire is black and the NEG(-) wire is blue. In UK, the RTN(+) wire is blue
and the NEG(-) wire is gray.

Description
The following table describes DCDU-12C power cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

135

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Table 3-21 DCDU-12C power cables

Issue 03 (2013-01-15)

Base
Station
Type

Applicati
on
Scenario

Power
Equipme
nt

CrossSectional
Area

Maxi
mu
m
Leng
th

Exterior

Functio
n

BTS3900
A (Ver.D)

In AC
scenarios,
a
DCDU-12
C is
installed in
a TMC11H
(Ver.D),
which
serves as a
transmissi
on cabinet.

EPU05A02 or
EPU05A04 in the
APM30H

One group of
cables with a
cross-sectional
area of 4 mm2
(0.006 in.2)

The
exterior is
shown by
illustration
1 in the
preceding
figure.

A
DCDU-1
2C power
cable
feeds DC
power
into a
DCDU-1
2C. A
DCDU-1
2C
distribute
s power
to each
compone
nt in the
cabinet.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

136

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Issue 03 (2013-01-15)

3 TMC11H Cabinet

Applicati
on
Scenario

Power
Equipme
nt

CrossSectional
Area

Maxi
mu
m
Leng
th

Exterior

In DC
scenarios,
a
DCDU-12
C is
installed in
a TMC11H
(Ver.D),
which
serves as a
transmissi
on cabinet
or the
power
cabinet.

l DC
junctio
n box
in the
RFC
when
the
TMC1
1H
serves
as the
power
cabinet

l One group
of cables
with a crosssectional
area of 25
mm2 (0.039
in.2) when
the
TMC11H
serves as the
power
cabinet

15 m
(59.2
1 ft)
when
the
TMC
11H
serve
s as a
trans
missi
on
cabin
et

l The
exterior
is
shown
by
illustrati
on 3 in
the
precedi
ng
figure
when
the
TMC11
H serves
as the
power
cabinet.

l Extern
al
power
equipm
ent
when
the
TMC1
1H
serves
as a
transmi
ssion
cabinet

l One group
of power
cables with a
crosssectional
area of 4
mm2 (0.006
in.2) when
the
TMC11H
serves as a
transmission
cabinet

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Functio
n

l The
exterior
is
shown
by
illustrati
on 2 in
the
precedi
ng
figure
when
the
TMC11
H serves
as a
transmis
sion
cabinet.

137

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base
Station
Type

Applicati
on
Scenario

Power
Equipme
nt

CrossSectional
Area

Maxi
mu
m
Leng
th

Exterior

DBS3900

In AC
scenarios,
a
DCDU-12
C is
installed in
a TMC11H
(Ver.D),
which
serves as a
transmissi
on cabinet.

EPU05A03 or
EPU05A05 in the
APM30H

One group of
cables with a
cross-sectional
area of 25 mm2
(0.039 in.2)

The
exterior is
shown by
illustration
1 in the
preceding
figure.

In DC
scenarios,
a
DCDU-12
C is
installed in
a TMC11H
(Ver.D),
which
serves as a
transmissi
on cabinet.

External
power
equipment

One group of
cables with a
cross-sectional
area of 4 mm2
(0.006 in.2)

10 m
(32.8
1 ft)

The
exterior is
shown by
illustration
2 in the
preceding
figure.

A
DCDU-12
C is
installed in
a
BTS3900
AL
(Ver.A).

l PDU03
D-01 in
the
BTS39
00AL
(Ver.A
) in DC
scenari
os

One group of
cables with a
cross-sectional
area of 16 mm2
(0.025 in2)

The
exterior is
shown by
illustration
3 in the
preceding
figure.

BTS3900
AL
(Ver.A)

Functio
n

l ETP48
400 in
the
BTS39
00AL
(Ver.A
) in AC
scenari
os

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

138

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

SOU Power Cable


The power cable for a service outlet unit (SOU) feeds AC power into the SOU from the AC
OUTPUT port on the EPU or EPS.

Exterior
The following figure shows the exterior of an SOU power cable.
Figure 3-38 Exterior of an SOU power cable

(1) C13 connector

(2) OT terminal (M4)

Description
The following table describes an SOU power cable.
Table 3-22 SOU power cable
Wire

Color

Silkscreen

Cross-Sectional Area

W1

Brown

2.5 mm2 (0.004 in.2)

W2

Green and yellow

PE

W3

Blue

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and regions. If cables
are purchased locally, the cables must comply with local rules and regulations.

Power Cable for an AC Heater


The power cable for an AC heater feeds power into an AC junction box from the AC OUTPUT
port on an EPU or EPS. Then the AC junction box distributes power to the AC heater. If an AC
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

139

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

heater is configured in the -48 V DC input scenario, one more AC power input must be added
for the heater. In this case, the maximum length of the power cable for the AC heater is 15 m
(49.21 ft).

Exterior
The following figure shows the exterior of a power cable for an AC heater.
Figure 3-39 Exterior of a power cable for an AC heater

(1) C13 connector

(2) OT terminal (M4)

Description
The following table describes the power cable for an AC heater.
Table 3-23 Power cable for an AC heater
Wire

Color

Silkscreen

Cross-Sectional
Area

W1

Brown

W2

Green and yellow

PE

1.5 mm2 (0.002


in.2)

W3

Blue

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and regions. If cables
are purchased locally, the cables must comply with local rules and regulations.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

140

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

FAN 02D Power Cable


A FAN 02D power cable feeds -48 V DC power into the FAN 02D in an APM30H or TMC11H
(Ver.D).

Exterior
Figure 3-40 and Figure 3-41 show the exterior of a FAN 02D power cable.
Figure 3-40 Exterior of a FAN 02D power cable in most regions

(1) 3V3 connector

(2) EPC4 or EPC6 connector

Figure 3-41 Exterior of a FAN 02D power cable in UK

(1) 3V3 connector

(2) EPC4 or EPC6 connector

Description
The following table describes a FAN 02D power cable.
Table 3-24 FAN 02D power cable

Issue 03 (2013-01-15)

Cable

Wire

Wire Color in Most


Regions

Wire Color in Other


Regions (UK)

FAN 02D power


cable

RTN(+)

Black

Blue

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

141

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Cable

3 TMC11H Cabinet

Wire

Wire Color in Most


Regions

Wire Color in Other


Regions (UK)

NEG(-)

Black

Gray

Power Cable for an AC Junction Box


A power cable for the AC junction box feeds AC power from the power devise into the AC
junction box. The power is divided into four AC outputs, which are then provided to other
components, such as the heater or heating film.

Exterior
The following figure shows the exterior of a power cable for an AC junction box.
Figure 3-42 Power cable for an AC junction box

(1) OT terminal

(2) Cord end terminal

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and regions. If cables
are purchased locally, the cables must comply with local rules and regulations.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

142

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Description
The following table describes a power cable for an AC junction box.
Table 3-25 Power cable for an AC junction box
Base
Stati
on
Type

Cabinet

Power
Equipme
nt

Wire

Color

CrossSectional
Area

Exterior

BTS3
900A

APM30H

EPU or EPS
subrack

Brown

Blue

1.5 mm2 (0.002


in.2)

EPU or EPS
subrack,
and
transfered
by AC
junction
box in
APM30H

Brown

The exterior is
shown by
illustration 1 in
the preceding
figure.

Blue

IBBS700
D/
IBBS700
T

EPU
subrack,
and
transfered
by AC
junction
box in
APM30H

Brown

Blue

BTS3900
AL AC

PDU05A-0
1

Brown

Blue

BTS3900
AL DC

PDU05A-0
1, and
transfered
by AC
junction
box in
BTS3900A
L AC

Brown

Blue

IBBS700
D/
IBBS700
T

PDU05A-0
1, and
transfered
by AC
junction
box in

Brown

TMC11H

BTS3
900A
L

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

1.5 mm2 (0.002


in.2)

1.5 mm2 (0.002


in.2)

2.5 mm2 (0.004


in.2)

The exterior is
shown by
illustration 2 in
the preceding
figure.

2.5 mm2 (0.004


in.2)

The exterior is
shown by
illustration 3 in
the preceding
figure.

2.5 mm2 (0.004


in.2)

143

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Stati
on
Type

Cabinet

3 TMC11H Cabinet

Power
Equipme
nt

Wire

Color

BTS3900A
L AC

Blue

CrossSectional
Area

Exterior

3.6.6 Signal Cables


This section describes the exteriors, functions, and pin assignments of the signal cables in the
TMC11H.

ELU Signal Cable


An electronic label unit (ELU) signal cable transmits the cabinet type to a monitoring board in
the cabinet.

Exterior
The following figure shows the exterior of an ELU signal cable.
Figure 3-43 Exterior of an ELU signal cable

(1) RJ45 connector

Description
The following table describes an ELU signal cable.
Table 3-26 ELU signal cable

Issue 03 (2013-01-15)

X1 End

X2 End

Color

Wire Type

X1.1

X2.1

White

Twisted pair

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

144

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

X1 End

X2 End

Color

X1.2

X2.2

Orange

X1.3

X2.3

White

X1.6

X2.6

Green

X1.5

X2.5

White

X1.4

X2.4

Blue

X1.7

X2.7

White

X1.8

X2.8

Brown

Wire Type

Twisted pair

Twisted pair

Twisted pair

Monitoring Signal Cable for the Door Status Sensor


A monitoring signal cable for the door status sensor is used to inform the monitoring board of
the door status that is obtained from the door status sensor. Cabinets configured with door status
sensors are as follows: APM30H, TMC11H, RFC, IBBS200D, IBBS200T, BTS3900AL, OMB,
IBBS700D and IBBS700T.

Exterior
Monitoring signal cables for door status sensors are classified into three types according to the
cabinets being monitored. Figure 3-44, Figure 3-45, and Figure 3-46 show their exteriors.
Figure 3-44 Exterior of a monitoring signal cable for the door status sensor (1)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

145

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-45 Exterior of a monitoring signal cable for the door status sensor (2)

NOTE

l Cable 1 has a 2-pin straight socket at one end, which is connected to the HPMI. Cable 1 has a bare wire
and a cord end terminal at the other end, which are connected to a door status sensor and a cable terminal
block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has a cord end
terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to the two ports
on one side of the cable terminal block.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

146

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Figure 3-46 Exterior of a monitoring signal cable for the door status sensor (3)

NOTE

l Cable 1 has a 2-pin straight socket at one end, which is connected to the GATE port on the PMU. Cable
1 has a bare wire and a cord end terminal at the other end, which are connected to a door status sensor
and a cable terminal block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has a cord end
terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to the two ports
on one side of the cable terminal block.

Description
Monitoring signal cables for door status sensors are classified into different types according to
the monitoring boards to which the door status is reported. The following table lists the
monitoring signal cables for door status sensors.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

147

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Table 3-27 Types of monitoring signal cables for door status sensors
Base Station
Type

Cabinet

Monitoring Board
to Which the Door
Status Is Reported

Exterior

BTS3900A
(Ver.B)

l RFC (Ver.B)

CMUA

The exterior is shown


in Figure 3-44.

l TMC11H (Ver.B)
l IBBS200D
(Ver.B) or
IBBS200T (Ver.B)
l RFC (Ver.C)

BTS3900A
(Ver.C)

CMUE

l TMC11H (Ver.C)
l IBBS200D
(Ver.C) or
IBBS200T (Ver.C)
l RFC (Ver.D)

BTS3900A
(Ver.D)

CMUEA

l TMC11H (Ver.D)
l IBBS200D
(Ver.D) or
IBBS200T
(Ver.D)
l IBBS700D

DBS3900

IBBS700T

CMUF

l TMC11H (Ver.B)

CMUA

l IBBS200D
(Ver.B) or
IBBS200T (Ver.B)
l TMC11H (Ver.C)

CMUE

l IBBS200D
(Ver.C) or
IBBS200T (Ver.C)
l TMC11H (Ver.D)

CMUEA

l IBBS200D
(Ver.D) or
IBBS200T
(Ver.D)
l BTS3900C

OMB

HEUA

OMB (Ver.C)

HEUB

l DBS3900
l BTS3900C
(Ver.C)
l DBS3900
(Ver.C)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

148

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Base Station
Type

Cabinet

Monitoring Board
to Which the Door
Status Is Reported

BTS3900AL
(Ver.A)

l BTS3900AL
(Ver.A)

CCU

Exterior

l IBBS700D
l IBBS700T
l BTS3900A
(Ver.B)

APM30H (Ver.B)

HPMI

APM30H (Ver.C)

HPMI

APM30H (Ver.D)

PMU

The exterior is shown


in Figure 3-45.

l DBS3900
l BTS3900A
(Ver.C)
l DBS3900
l BTS3900A
(Ver.D)

The exterior is shown


in Figure 3-46.

l DBS3900

Monitoring Signal Transfer Cable for the Fan in the Front Door
A monitoring signal transfer cable for the fan in the front door feeds power into the fan in the
front door of the APM30H or TMC11H. It also transmits fan monitoring signals to a monitoring
board in the cabinet.

Cable Type
The following table lists the types of monitoring boards to which the monitoring signals are
reported. Monitoring signal cables vary according to the boards.
Table 3-28 Cable type

Issue 03 (2013-01-15)

Cable

Cabinet

Monitoring Board to
Which the
Monitoring Signals
Are Reported

Exterior

Monitoring
signal
transfer
cable for
the fan in
the front
door

APM30H (Ver.B) or
TMC11H (Ver.B)

CMUA

APM30H (Ver.C) or
TMC11H (Ver.C)

CMUE

The exterior is shown by


illustration 1 in the
following figure.

APM30H (Ver.D) or
TMC11H (Ver.D)

CMUEA

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

The exterior is shown by


illustration 2 in the
following figure.

149

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

3 TMC11H Cabinet

Exterior
The following figure shows the exteriors of monitoring signal transfer cables for fans in the front
doors.
Figure 3-47 Exteriors of monitoring signal transfer cables for fans in the front doors

(1) 4-pin connector

(2) Interconnection terminal

Description
The following table describes a monitoring signal transfer cable for the fan in the front door.
Table 3-29 Monitoring signal transfer cable for the fan in the front door

Issue 03 (2013-01-15)

Wire

X1 End

X2 End

Color

W1

X1.1

X2.1

Black

W2

X1.2

X2.2

Black

W3

X1.3

X2.3

Black

W4

X1.4

X2.4

Black

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

150

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

IBBS200D Cabinet

About This Chapter


This chapter describes the IBBS200D cabinet exterior, engineering specifications, application
scenarios, as well as boards, modules, and cables in the IBBS200D cabinet.
4.1 Cabinet Exterior
The integrated battery backup system with direct cooling (IBBS200D) uses fans to dissipate heat
from the cabinet and can provide backup power to the APM30H.
4.2 Cabinet Engineering Specifications
This section describes the engineering specifications of the IBBS200D, including the electrical
specifications, equipment specifications, and environment specifications.
4.3 Cabinet Interior
This section describes the components and boards in the IBBS200D. The power distribution
equipment is installed on the upper right wall of the cabinet interior, and the monitoring
equipment is installed inside the cabinet door.
4.4 IBBS200D Components
This section describes the mandatory and optional components in an IBBS200D.
4.5 IBBS200D Cables
The IBBS200D cables consist of the power cables, equipotential cables, PGND cables, and
signal cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

151

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

4.1 Cabinet Exterior


The integrated battery backup system with direct cooling (IBBS200D) uses fans to dissipate heat
from the cabinet and can provide backup power to the APM30H.
The following figure shows the exterior of the IBBS200D.
Figure 4-1 Exterior of the IBBS200D

4.2 Cabinet Engineering Specifications


This section describes the engineering specifications of the IBBS200D, including the electrical
specifications, equipment specifications, and environment specifications.

Electrical Specifications
The following table lists the electrical specifications of the IBBS200D.
Table 4-1 Electrical specifications

Issue 03 (2013-01-15)

Item

Specifications

Input voltage range

-38.4 V DC to -57 V DC

Maximum capacity of the


storage batteries

48 V, 184 Ah

Heat dissipation in the cabinet

The difference between the temperature in the battery


cabinet and the ambient temperature must be less than 5oC
(41oF).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

152

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Equipment Specifications
The following table lists the equipment specifications of the IBBS200D.
Table 4-2 Equipment specifications
Item

Specifications

Remarks

Dimensions (H x
W x D)

Cabinet (without the base): 700


mm x 600 mm x 480 mm (27.56 in.
x 23.62 in. x 18.90 in.)

Base: 200 mm x 600 mm x 434 mm


(7.87 in. x 23.62 in. x 17.09 in.)
Cabinet weight

40 kg (88.2 lb)

The cabinet is configured only


with monitoring boards, power
distribution box, and cables.

Weight of storage
batteries

12 V 92 Ah storage battery: 33.5


kg (73.87 lb)

The total capacity can expand to 48


V 184 Ah (two 48 V 92 Ah battery
packs).

NOTE
Storage batteries from different
manufacturers have different
specifications. The specifications
listed above are for the commonly
used storage batteries.

Method of
installation

It can be installed on the ground. It


can be also installed on the
TMC11H or APM30H in stack
mode.

In stack mode, the IBBS200D must


be installed under the TMC11H or
APM30H.

Environment Specifications
The IBBS200D can be used outdoors. The following table lists the environment specifications
of the IBBS200D.
Table 4-3 Environment specifications

Issue 03 (2013-01-15)

Item

Specifications

Remarks

Operating
temperatur
e

-40oC to +40oC (-40oF +104oF)

Heating films must be used in cold


areas.

Relative
humidity

5% RH to 100% RH

Altitude

-60 m to +4000 m (-196.85 ft to


+13123.2 ft)

From the altitude of 1800 m (5905.44


ft), the maximum operating
temperature drops by 1oC (33.8oF)
each time the altitude increases by 220
m (721.78 ft).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

153

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Item

Specifications

Remarks

Wind
speed

67 m/s

Storage
temperatur
e

-40oC to +70oC (-40oF to +158oF)

Dustproof
and
waterproof

IP34

Noise

Meeting the ETS 300 753 4.1E


standard (rural area)

4.3 Cabinet Interior


This section describes the components and boards in the IBBS200D. The power distribution
equipment is installed on the upper right wall of the cabinet interior, and the monitoring
equipment is installed inside the cabinet door.
The following figure shows the interior of the IBBS200D.
Figure 4-2 Interior of the IBBS200D

The following table describes the components in the IBBS200D.\

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

154

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Table 4-4 Components in the IBBS200D


No
.

Component

Option
al or
Manda
tory

Max
imu
m
Qua
ntit
y in
a
Sin
gle
Cab
inet

Remarks

Fan mounting
frame

Mandat
ory

The fan mounting frame is installed on the front


door of the cabinet, and configured with a fan.

CMUEA

Mandat
ory

The central monitoring unit type EA (CMUEA)


controls temperature, detects Boolean alarm, and
identifies the ELU.

ELU

Mandat
ory

The electronic label unit (ELU) reports the cabinet


type automatically to facilitate troubleshooting.

Storage
battery

Mandat
ory

The storage batteries provide long-duration


backup power for base stations.

Power
distribution
box

Mandat
ory

The power distribution box is installed on the


upper right wall of the cabinet interior. It transfers
and distributes input power to the TEC or fan and
storage batteries.

Door status
sensor

Mandat
ory

The door status sensor monitors the status (open


or closed) of the cabinet door.

Heating film

Optiona
l

The IBBS200D must be configured with a heating


film in cold areas. The heating film is not required
in general areas.

Junction
terminal for
the input
power cable of
the heating
film

Mandat
ory

The junction terminal provides the input power


port for the heating film.

4.4 IBBS200D Components


This section describes the mandatory and optional components in an IBBS200D.

4.4.1 Fan Mounting Frame


In an IBBS200D, the fan mounting frame is configured with a fan and is installed on the front
door of the cabinet. The fan promotes the inner and outer air circulation of the cabinet to ensure
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

155

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

that the cabinet work within an acceptable temperature range. This allows the batteries to work
properly.

Exterior
The following figure shows the exterior of the fan mounting frame in an IBBS200D (Ver.B).
Figure 4-3 Exterior of the fan mounting frame in an IBBS200D (Ver.B)

(1) Fan

(2) CMUA

The following figure shows the exterior of the fan mounting frame in an IBBS200D (Ver.C).

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

156

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-4 Exterior of the fan mounting frame in an IBBS200D (Ver.C)

(1) Fan

(2) CMUE

The following figure shows the exterior of the fan mounting frame in an IBBS200D (Ver.D).
Figure 4-5 Exterior of the fan mounting frame in an IBBS200D (Ver.D)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

157

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Functions
A fan mounting frame performs the following functions:
l

The fan promotes the inner and outer air circulation of the cabinet to ensure that the cabinet
work within an acceptable temperature range. This allows the batteries to work properly.

The monitoring board installed in the fan mounting frame collects the alarm signals from
the door status sensor, battery temperature sensor, fans, and smoke sensor in the cabinet,
and it reports these alarm signals to the PMU through an RS485 signal cable.

The types of monitoring boards installed in the fan mounting frames vary with the versions of
cabinets. The following table lists the types of monitoring boards.
Table 4-5 Types of monitoring boards installed in the fan mounting frames
Cabinet

Monitoring Board

IBBS200D (Ver.B)

CMUA

IBBS200D (Ver.C)

CMUE

IBBS200D (Ver.D)

CMUEA

Signal Cable Delivered with a Fan


Exterior
IBBS200D (Ver.B), IBBS200D (Ver.C), and IBBS200D (Ver.D) have signal cables delivered
along with them. The following figure shows the exterior of such a signal cable.
Figure 4-6 Exterior of a signal cable delivered with a fan

NOTE

The signal cable delivered with a fan feeds power into the fan and transmits signals to a monitoring board.

Description
The following table describes a signal cable delivered with the fan.
Table 4-6 Description

Issue 03 (2013-01-15)

Wire

A
End

Color

Description

W1

A.1

Red

Connects to the positive pole of the power supply.

W2

A.2

Yello
w

Imports PWM speed-adjusting signals.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

158

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Wire

A
End

Color

Description

W3

A.3

Blue

Exports alarm or speed signals.

W4

A.4

Black

Connects to the negative pole of the power supply.

NOTE

The color of the signal cable delivered with a fan depends on the manufacturer.

4.4.2 CMUEA
The central monitoring unit type EA (CMUEA) monitors the fans, Heater Assembly Unit, and
cabinet temperature. A CMUEA can be used in the AMP30H, RFC, TMC11H, IBBS200D,
IBBS200T, or IBBS700D cabinet.

Exterior
The following figure shows the exterior of a CMUEA.
Figure 4-7 Exterior of a CMUEA

Ports
The following figure shows the ports on a CMUEA.
Figure 4-8 Ports on a CMUEA

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

159

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

The following table lists information about ports on a CMUEA.


Table 4-7 Ports on a CMUEA
No
.

Silkscreen
on the
Panel

Description

(1)

TEMP2

Reserved port, connected to the temperature sensor.

(2)

WATER

Connected to the water sensor.

(3)

IFAN4

(4)

IFAN3

Connected to the inner air circulation to receive alarms related to the


inner air circulation.

(5)

IFAN2

(6)

IFAN1

(7)

TEC

Connected to the TEC cooler to receive alarms related to the TEC cooler.

(8)

TEMP1

l In an RFC, this port is connected to the temperature sensor at the air


intake vent of the cabinet to receive temperature alarms about the
RFC.
l In an IBBS200D, IBBS200T, IBBS700D, or IBBS700T, this port is
connected to the battery temperature sensor to receive alarm signals
about the battery temperature.

(9)

COM_OUT

It is an RS485 signal port, which communicates with lower-level


cascading ports and reports monitoring information.
l In the APM30H, this port is connected to the PMU.
l In an RFC, TMC11H, IBBS200D, IBBS200T, IBBS700D, or
IBBS700T, this port is connected to a lower-level CMUEA.

(10
)

COM_IN

RS485 signal port for communicating with upper-level cascading ports


and reporting monitoring information.
l In the APM30H, this port is connected to the BBU.
l In the RFC or TMC11H, this port is connected to the BBU or an
upper-level CMUEA.
l In an IBBS200D, IBBS200T, IBBS700D, or IBBS700T, this port is
connected to the PMU or an upper-level CMUEA.

(11
)

ELU

Port for connecting the ELU to report the cabinet type.

(12
)

GATE

Boolean signal port, which is connected to the door status sensor.

(13
)

IN0, IN1,
and IN2

Boolean signal port.


l In the APM30H, RFC, TMC11H, IBBS200D, or IBBS200T, these
ports are reserved.
l In the IBBS700D or IBBS700T, IN0 is connected to the heater, and
IN1 and IN2 are reserved.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

160

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

No
.

Silkscreen
on the
Panel

Description

(14
)

SMOKE

Boolean signal port.

4 IBBS200D Cabinet

l In the APM30H, RFC, TMC11H, IBBS200D, or IBBS200T, this


port is connected to the smoke sensor.
l In the IBBS700D or IBBS700T, this port is not involved.

(15
)

EFAN1

(16
)

EFAN2

(17
)

PWR

Connected to the outer air circulation fan to receive its alarm signals.

Power input port providing DC power input for the board.

Indicators
The two indicators on the CMUEA panel indicate the status of the CMUEA. The following table
describes their meanings.
Table 4-8 Indicators on the CMUEA panel
Silkscr
een

Color

State

Meaning

RUN

Green

Blinking (on for 1s and


off for 1s)

The board is functional and communicating


with the BBU properly.

Blinking (on for 0.125s


and off for 0.125s)

The board is functional but fails to


communicate with the BBU or the board is
not registered.

Steady on

The board is in the power-on self-check


status.

Steady off

There is no power supply, or the board is


faulty.

Steady off

No alarm is reported.

Steady on

An alarm is generated, and the board must be


replaced.

Blinking (on for 1s and


off for 1s)

An alarm is generated, and the alarm may be


caused by an associated board or port fault.
Therefore, you need to locate the fault before
determining whether to replace the board.

ALM

Issue 03 (2013-01-15)

Red

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

161

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

DIP Switch
On the CMUEA, there is a DIP switch J18, which is used to set the working mode of the CMUEA
according to the cabinet type. Figure 4-9 shows the position of the DIP switch on the CMUEA.
Figure 4-9 Position of DIP switch on a CMUEA

In different types of cabinets, DIP switches on the CMUEA are set in different ways, as shown
in Figure 4-10.
NOTE

The white boxes indicate the positions of all bits in the DIP switch.

Figure 4-10 DIP switch setting on the CMUEA in different cabinets

4.4.3 Power Distribution Box


The power distribution box is installed on the upper right inner wall of the cabinet, which controls
the two storage battery groups separately and the DC power supply to the fan or TEC.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

162

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Exterior
The following figure shows the exterior of a power distribution box.
Figure 4-11 Exterior of a power distribution box

Port
The following table describes the ports on a power distribution box.
Table 4-9 Ports on the power distribution box

Issue 03 (2013-01-15)

No.

Silkscreen

Meaning

Description

(1)

BAT

Input power
cable port for
storage batteries

It supports a one-hole OT terminal (M8)


installed on a cable with a cross-sectional area
of 35 mm2 (0.054 in.2).

(2)

BAT_SW0

Circuit breaker
for the upper
storage batteries

It controls the power supply to upper storage


batteries in the cabinet. The circuit breaker
requires 250 A current.

(3)

FAN/
TEC_OUTPU
T

Power output
port for a fan or
TEC

It supports EPC4 connectors and requires 30 A


current.

(4)

BAT_SW1

Circuit breaker
for the lower
storage batteries

It controls the power supply to lower storage


batteries in the cabinet. The circuit breaker
requires 250 A current.

(5)

BAT

Input power
cable port for
storage batteries

It supports a one-hole OT terminal (M8)


installed on a cable with a cross-sectional area
of 35 mm2 (0.054 in.2).

(6)

FAN/
TEC_INPUT

Power input port


for a fan or TEC

It supports EPC4 connectors and requires 30 A


current.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

163

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Wire
The following figure shows the input and output power cables for a power distribution box.
Figure 4-12 Cables for a power distribution box

(1) RTN(+) cable for upper storage (2) Power transfer cable for a TEC or (3) NEG(-) wire for lower storage
batteries
fan assembly
batteries
(4) NEG(-) wire for upper storage
batteries

(5) RTN(+) wire for lower storage


batteries

4.4.4 Storage Battery


Storage batteries is the store power equipment.
NOTE

Storage batteries from different manufacturers differ in exteriors and technical specifications. In this section, a
12 V 92 Ah storage battery is described as an example.

Exterior
The following figure shows the exterior of a 12 V 92 Ah storage battery.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

164

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-13 Exterior of a 12 V 92 Ah storage battery

Configuration
The IBBS200T and IBBS200D support two types of storage battery groups: 48 V 92 Ah and 48
V 184 Ah.
l

Two 48 V 92 Ah storage battery groups are connected in parallel and serve as a 48 V 184
Ah storage battery group.

Each group consists of four storage batteries.

Technical Specifications
The following table describes the technical specifications of a 12 V 92 Ah storage battery.
Table 4-10 Technical specifications of a 12 V 92 Ah storage battery
Storage Battery Type

Dimensions (H x W x D)

Weight

12 V, 92 Ah

105 mm x 287 mm x 390 mm


(11.30 in. x 4.13 in. x 15.35
in.)

33.5 kg (73.85 lb)

108 mm x 287 mm x 393 mm


(11.30 in. x 4.25 in. x 15.47
in.)

35 kg (77.16 lb)

4.4.5 ELU
An electronic label unit (ELU) reports the cabinet type automatically to facilitate
troubleshooting.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

165

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Exterior
The following figure shows the exterior of an ELU.
Figure 4-14 Exterior of an ELU

(1) Shell

(2) RJ45 port

NOTE

The ELU in a BTS3900 or BTS3900L has no shell.

The board collecting information from the ELU varies according to the cabinet, as listed in the
following table.
Table 4-11 Monitoring boards to which an ELU reports information

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Board Collecting
Information from
the ELU

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B) and BTS3900L (Ver.B)

FMUC

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C) and BTS3900L (Ver.C)

FMUE

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D) and BTS3900L (Ver.D)

FMUEA

BTS3900A
(Ver.B)

APM30H (Ver.B), TMC11H (Ver.B), RFC


(Ver.B), IBBS200D (Ver.B), and IBBS200T
(Ver.B)

CMUA

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

166

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Base Station
Type

Cabinet

Board Collecting
Information from
the ELU

BTS3900A
(Ver.C)

APM30H (Ver.C), TMC11H (Ver.C), RFC


(Ver.C), IBBS200D (Ver.C), and IBBS200T
(Ver.C)

CMUE

BTS3900A
(Ver.D)

APM30H (Ver.D), TMC11H(Ver.D), RFC


(Ver.D), IBBS200D(Ver.D), IBBS200T
(Ver.D), and IBBS700D

CMUEA

IBBS700T

CMUF

BTS3900C
(Ver.C)

OMB (Ver.C)

HEUB

BTS3900AL
(Ver.A)

BTS3900AL (Ver.A), IBBS700D, IBBS700T

CCU

Installation Position
Positions of ELUs vary in different cabinets. The following figure shows their positions.
Figure 4-15 Position of the ELU in a BTS3900 cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

167

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-16 Position of the ELU in a BTS3900L cabinet

Figure 4-17 Position of the ELU in an APM30H or IBBS200D cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

168

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

NOTE

An ELU is located on the right inner wall of the APM30H, TMC11H, or RFC, or on the left inner wall of
the IBBS200D or IBBS200T. The preceding figure shows an APM30H and an IBBS200D as an example.

Figure 4-18 Position of the ELU in an OMB

Figure 4-19 Position of the ELU in a BTS3900AL cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

169

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-20 Position of the ELU in a IBBS700D cabinet

NOTE

In the IBBS700D, when the cabinet is configured with a CCU, the ELU is above the CCU. When the cabinet
is not configured with a CCU, the ELU is on the right of the CMUEA.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

170

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-21 Position of the ELU in a IBBS700T cabinet

NOTE

In the IBBS700T, when the cabinet is configured with a CCU, the ELU is above the CCU. When the cabinet
is not configured with a CCU, the ELU is on the left of the CMUF.

4.4.6 Heating Film


The heating film functions in the low-temperature environment to provide the suitable storage
and operating temperature for the storage batteries. When the operating temperature is lower
than the temperature specification of the storage batteries, the battery capacity declines.
Therefore, the heating film is installed to ensure that the storage batteries work in a proper
temperature range. The heating film is optional.
NOTE

An IBBS200D has two heating films, which are installed on the upper and lower pallets, respectively.

Exterior
The following figure shows the exterior of a heating film.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

171

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-22 Exterior of a heating film

Technical Specifications
The technical specifications of a heating film are as follows:
Table 4-12 Technical specifications of a heating film
Counter

Specification

Temperature range in the cabinet when the


heating film starts working

< 1oC (6oC) or 33.8oF (42.8oF)

Temperature range in the cabinet when the


heating film stops working

> 15oC (3oC) or 59 oF (37.4oF)

Rated heating power

100 W

Rated operating voltage

220 V AC

4.4.7 Door Status Sensor


A door status sensor reports the status (open or closed) of a door. It is installed in any of the
following cabinets: BTS3900AL, OMB, OMB (Ver.C), APM30H, RFC, TMC11H, IBBS200D,
IBBS200T, IBBS700D, and IBBS700T.

Exterior
A door status sensor consists of a magnet and a switch. The following figures show the exteriors
of them.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

172

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-23 Exterior of the magnet of a door status sensor

(1) Magnetic shell

(2) Magnet

The following figure shows the exterior of the switch of a door status sensor.
Figure 4-24 Exterior of the switch of a door status sensor

Installation Position
Positions of door status sensors vary in different cabinets. The following figure shows their
positions.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

173

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

NOTE

l A door status sensor is installed at the same position in the BTS3900AL (Ver.A), IBBS700D, and
IBBS700T. Figure 4-25 uses the BTS3900AL (Ver.A) as an example.
l A door status sensor is installed at the same position in the OMB and OMB (Ver.C). Figure 4-26 uses
the OMB (Ver.C) as an example.
l A door status sensor is installed at the same position in the following cabinets: APM30H (Ver.B),
APM30H (Ver.C), APM30H (Ver.D), RFC (Ver.B), RFC (Ver.C), RFC (Ver.D), TMC11H (Ver.B),
TMC11H (Ver.C), TMC11H (Ver.D), IBBS200D (Ver.B), IBBS200D (Ver.C), IBBS200D (Ver.D),
IBBS200T (Ver.B), IBBS200T (Ver.C), and IBBS200T (Ver.D). Figure 4-27 uses the APM30H
(Ver.D) as an example.

Figure 4-25 Position of a door status sensor in the BTS3900AL (Ver.A)

Figure 4-26 Position of a door status sensor in the OMB (Ver.C)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

174

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-27 Position of a door status sensor in the APM30H (Ver.D)

4.4.8 Temperature Sensor


The temperature sensor monitors the temperature in the cabinet. It is installed in the following
cabinets: BTS3900AL, RFC, IBBS200T, IBBS200D, OMB, IBBS700T, and IBBS700D.

Exterior
The following figure shows the exterior of a temperature sensor.
Figure 4-28 Exterior of a temperature sensor

(1) Temperature sensor

(2) 4-pin connector

Installation Position
Positions of temperature sensors vary in different cabinets. The following figure shows their
positions.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

175

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

NOTE

l A temperature sensor is installed at the same position in the RFC (Ver.B), RFC (Ver.C), and RFC
(Ver.D). Figure 4-30 uses the RFC (Ver.D) as an example.
l A temperature sensor is installed at the same position in the IBBS200T (Ver.B), IBBS200T (Ver.C),
and IBBS200T (Ver.D). Figure 4-31 uses the IBBS200T (Ver.D) as an example.
l A temperature sensor is installed at the same position in the IBBS200D (Ver.B), IBBS200D (Ver.C),
and IBBS200D (Ver.D). Figure 4-32 uses the IBBS200D (Ver.D) as an example.
l A temperature sensor is installed at the same position in the OMB (Ver.C), and OMB. Figure 4-33
uses the OMB (Ver.C) as an example.

Figure 4-29 Position of the temperature sensor in a BTS3900AL (Ver.A) cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

176

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-30 Position of the temperature sensor in an RFC (Ver.D)

Figure 4-31 Position of the temperature sensor in an IBBS200T (Ver.D)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

177

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-32 Position of the temperature sensor in an IBBS200D (Ver.D)

Figure 4-33 Position of the temperature sensor in an OMB (Ver.C)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

178

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-34 Position of the temperature sensor in an IBBS700D

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

179

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-35 Position of the temperature sensor in an IBBS700T

Technical Specifications
The following table lists the technical specifications of a temperature sensor.
Table 4-13 Technical specifications of a temperature sensor
Counter

Specification

Operating voltage

3.0 V DC to 5.5 V DC

Temperature measurement range

-55C to +125C (-131 F to +257 F)

Temperature measurement error

2C (35.6F)

4.5 IBBS200D Cables


The IBBS200D cables consist of the power cables, equipotential cables, PGND cables, and
signal cables.

4.5.1 Cable List


IBBS200D cables consist of the PGND cables, equipotential cables, power cables, and signal
cables.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

180

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Power Cables, PGND Cables, and Equipotential Cables


The following table lists the power cables, PGND cables, and equipotential cables.
Table 4-14 Power cables, PGND cables, and equipotential cables

Issue 03 (2013-01-15)

Classi
ficati
on

Cable

Cables
to be
install
ed
onsite

One End

The Other End

Connector

Installation
Position

Connector

Installation
Position

Power Cable
for a Power
Distribution
Box

OT terminal

RTN(+) and
NEG(-)
terminals on
the BAT
terminal block
on the EPU

OT terminal

RTN(+) and
NEG(-)
terminals on
the BAT
terminal block
on the power
distribution
box in the
IBBS200D

Storage
Battery Power
Cable

OT terminal

Copper bar on
the power
distribution
box

OT terminal

Storage
battery

Power Cable
for the Fan in
an IBBS200D

EPC4 or
EPC6
connector

LOAD8 port
on the EPU

EPC4 or
EPC6
connector

FAN/
TEC_INPUT
port on the
power
distribution
box in the
IBBS200D

Power Cable
for the
Heating Film

OT terminal

L1 and N1 or
L2 and N2
terminals on
the AC
junction box
in the
APM30H

OT terminal

L and N
terminals on
the junction
terminal for
the input
power cable
for the heating
film in the
IBBS200D

2.7.3 PGND
Cable

OT terminal

Ground bar in
the cabinet

OT terminal

Ground busbar
outside the
cabinet

2.7.4
Equipotential
Cable

OT terminal

Ground bar in
the upper
cabinet

OT terminal

Ground bar in
the lower
cabinet

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

181

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Classi
ficati
on

Cable

Cables
install
ed
before
deliver
y

4 IBBS200D Cabinet

One End

The Other End

Connector

Installation
Position

Connector

Installation
Position

Signal Cables
The following table describes the signal cables.
Table 4-15 Signal cables
Classi
ficati
on

Cable

Cables
to be
install
ed
onsite
Cables
install
ed
before
deliver
y

One End

The Other End

Connecto
r

Installation
Position

Connect
or

Installation
Position

Monitoring
Signal
Cable for
the Battery
Cabinet

RJ45
connector

COM_IN port on
the CMUEA in the
IBBS200D or
IBBS200T

RJ45
connector

COM_485 port on
the PMU

ELU Signal
Cable

RJ45
connector

ELU

RJ45
connector

ELU port on the


CMUEA

Monitoring
Signal
Cable for
the Door
Status
Sensor

Bare wire

GATE port on the


CMUEA

Bare wire

Door status sensor

4.5.2 Cable Connections


This section describes the principles for connecting power cables and signal cables in the
IBBS200D.

Power Cable Connections


This section describes the power cable connections in the IBBS200D.
The following figure shows the power cable connections in the IBBS200D.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

182

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-36 Power cable connections in the IBBS200D

(1) Cable between the battery pack (2) Power Cable for the Fan in an
and the short-circuiting copper bar IBBS200D

(3) Storage Battery Power Cable

(4) Cable between the battery pack (5) Power Cable for the Heating Film (6) Power Transfer Cable for the Fan
and the short-circuiting copper bar
in the IBBS200D

Monitoring Signal Cable Connections


This section provides reference for onsite installation of monitoring signal cables.
Figure 4-37 shows the monitoring signal cable connections in the IBBS200D.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

183

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-37 Monitoring signal cable connections in the IBBS200D

(1) Monitoring signal cable for the door


status sensor

(2) ELU signal cable (3) Monitoring signal cable for the battery
cabinet

4.5.3 PGND Cable


PGND cables ensure that cabinets and internal components are properly grounded and that base
stations run properly. PGND cables include classified into PGND cables for cabinets and PGND
cables for components.

Exterior
The following figure shows the exterior of a PGND cable.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

184

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-38 Exterior of a PGND cable

(1) One-hole OT terminal

(2) Two-hole OT terminal

NOTE

In most cases, the PGND cable is a yellow and green colored cable. When 110 V dual-live-wire power is
supplied for BTS3900A (Ver.C) and BTS3900A (Ver.D) cabinets, the PGND cables are green.

Description
The cross-sectional areas and maximum lengths of PGND cables vary according to the types of
cabinets. Table 4-16 and Table 4-17 describe PGND cables.
Table 4-16 PGND cables for cabinets

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B) 15 m (49.21


and BTS3900L
ft)
(Ver.B)

25 mm2
(0.039
in.2)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

One-hole
OT
terminal
(M8)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

185

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Issue 03 (2013-01-15)

4 IBBS200D Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900A
(Ver.B)

RFC (Ver.B)

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.C)

RFC (Ver.C)

8 m (26.25
ft)

25 mm2
(0.039
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.D)

RFC (Ver.D)

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.D)

IBBS700D and
IBBS700T

5 m (16.4 ft)

35 mm2
(0.054
in.2)

The cable
has a onehole OT
terminal
(M6) on
the
cabinet
side and a
one-hole
OT
terminal
(M8) on
the
ground
bar side.

The exterior
is shown by
illustration
1 in the
preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

186

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900AL
(Ver.A)

BTS3900AL
(Ver.A)

8 m (26.25
ft)

35 mm2
(0.054
in.2)

Select
one of the
followin
g
specificat
ions
based on
the onsite
situation:

The exterior
is shown by
illustration
2 or 3 in the
preceding
figure.

l The
cable
has a
twohole
OT
termi
nal
(M6)
at
each
end,
and
the
distan
ce
betwe
en the
two
holes
of
each
twohole
OT
termi
nal is
15.8
mm
(0.62
in.).
l The
cable
has a
twohole
OT
termi

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

187

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base Station
Type

Cabinet

4 IBBS200D Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

nal
(M6)
on the
cabin
et side
and a
onehole
OT
termi
nal
(M6)
on the
groun
d bar
side.
The
distan
ce
betwe
en the
two
holes
of the
twohole
OT
termi
nal is
15.8
mm
(0.62
in.).
IBBS700D and
IBBS700T

Issue 03 (2013-01-15)

5 m (16.4 ft)

35 mm2
(0.054
in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

The cable
has a onehole OT
terminal
(M6) on
the
cabinet
side and a
one-hole
OT
terminal
(M8) on
the
ground
bar side.

The exterior
is shown by
illustration
1 in the
preceding
figure.

188

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900C
(Ver.C)

OMB (Ver.C)

15 m (49.21
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

DBS3900

APM30H (Ver.B)
series cabinets

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

APM30H (Ver.C)
series cabinets

8 m (26.25
ft)

25 mm2
(0.039
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

APM30H
(Ver.D) series
cabinets

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

Table 4-17 PGND cables for components

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

One-hole
OT
terminal
(M4)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

189

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900A
(Ver.B)

APM30H (Ver.B)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M4)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

IBBS200D
(Ver.B)
IBBS200T
(Ver.B)

BTS3900C
(Ver.C)

OMB (Ver.C)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M6)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

BTS3900AL
(Ver.A)

BTS3900AL

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M6)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

4.5.4 Equipotential Cable


An equipotential cable connects the PGND terminals of two cabinets. It ensures equipotential
bonding between cabinets and safe operation of base stations.

Exterior
The following figure shows the exterior of an equipotential cable.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

190

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-39 Exterior of an equipotential cable

(1) One-hole OT terminal

(2) Two-hole OT terminal

NOTE

In most cases, the equipotential cable is a green and yellow cable. When 110 V dual-live-wire power is
supplied for the cabinets used by the BTS3900A (Ver.C) or BTS3900A (Ver.D), the equipotential cable
is green.

Description
The following table describes equipotential cables.
Table 4-18 Equipotential cables
Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900
(Ver.B)

16 mm2 (0.025 in.2)

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

16 mm2 (0.025 in.2)

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 2 in the preceding
figure.

BTS3900
(Ver.C)
BTS3900
(Ver.D)
BTS3900A
(Ver.B)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

191

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900A
(Ver.C)

The cross-sectional areas of


cables vary according to the
way that cabinets are
combined.

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

l 16 mm2 (0.025 in.2) for


stacked cabinets
l 25 mm2 (0.039 in.2) for
side-by-side cabinets
BTS3900A
(Ver.D)

Issue 03 (2013-01-15)

16 mm2 (0.025 in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

192

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900AL
(Ver.A)

The cross-sectional areas of


cables vary according to the
way that cabinets are
combined.

l When
a
BTS39
00AL
AC
cabinet
is
combi
ned
with a
BTS39
00AL
DC
cabinet
or an
IBBS7
00D/
IBBS7
00T,
each
end of
the
cable
has a
twohole
OT
termin
al
(M6),
and the
distanc
e
betwee
n the
two
holes
of each
twohole
termin
al is
15.8
mm
(0.62
in.).

The exterior is shown by


illustration 2 or 3 in the
preceding figure.

l When a BTS3900AL AC
cabinet is combined with a
BTS3900AL DC cabinet
or an IBBS700D/
IBBS700T, the crosssectional area of the cable
is 35 mm2 (0.054 in.2)
l When a BTS3900AL AC
cabinet is combined with a
TMC11H (Ver.C), the
cross-sectional area of the
cable is 25 mm2 (0.039in.
2).

l When
a

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

193

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Cross-Sectional Area

4 IBBS200D Cabinet

Connect
or

Exterior

BTS39
00AL
AC
cabinet
is
combi
ned
with a
TMC1
1H
(Ver.C
), the
cable
has a
twohole
OT
termin
al
(M6)
on the
BTS39
00AL
AC
cabinet
side
and a
onehole
OT
termin
al
(M6)
on the
TMC1
1H
(Ver.C
) side.
The
distanc
e
betwee
n the
two
holes
of each
twohole

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

194

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Cross-Sectional Area

4 IBBS200D Cabinet

Connect
or

Exterior

termin
al is
15.8
mm
(0.62
in.).

4.5.5 Power Cables


This section describes the exteriors, functions, and pin assignments of the power cables in the
IBBS200D.

Storage Battery Power Cable


Storage battery power cables connect storage batteries and the power distribution boxes in
battery cabinets. The power cables include groups to wiring copper bars and connect the copper
bars between storage batteries.

Storage Battery Power Cables Between Battery Groups and Wiring Copper Bars
The following figure shows the exteriors of the power cables.
Figure 4-40 Exteriors of storage battery power cables between battery groups and wiring copper
bars

(1) OT terminal (M8)

Issue 03 (2013-01-15)

(2) OT terminal (M6)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

195

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

The following table describes the storage battery power cables between battery groups and
wiring copper bars.
Table 4-19 Storage battery power cables between battery groups and wiring copper bars
Power Equipment

Wire

Color

Cross-Sectional
Area

Exterior

EPU03A-02 or
EPU03A-04,
EPU05A-02 or
EPU05A-04, and
ETP48400

RTN
(+)

Red

35 mm2 (0.054 in.


2)

NEG
(-)

Black

The exterior is shown


by illustration 1 in the
preceding figure.
When the power
equipment is
EPU05A-02,
EPU05A-04, or
ETP48400 in UK, the
RTN(+) wire is blue and
the NEG(-) wire is gray.

EPS01A or EPS01C

RTN
(+)

Red

16 mm2 (0.025 in.


2)

NEG
(-)

Black

The exterior is shown


by illustration 2 in the
preceding figure.

Copper Bars Between Storage Batteries


Copper bars are delivered with the storage batteries. The following figure shows the exterior of
a copper bar.
Figure 4-41 Exterior of a copper bar between storage batteries

Power Cable for a Power Distribution Box


A power cable for a power distribution box connects the power system to the power distribution
box in a battery cabinets, which are IBBS200D, IBBS200T, IBBS700D, and IBBS700T, and
provide input power to batteries in these cabinets.

Exterior
Power cables for power distribution boxes vary according to the power equipment. The following
figure shows the exteriors of the power cables.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

196

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-42 Exteriors of power cables for power distribution boxes

(1) Power series 120 connector (2) OT terminal (M6) (3) Power series 175 connector (4) OT terminal (M8)

Description
The following table describes the power cables for power distribution boxes.
Table 4-20 Power cables for power distribution boxes
Cabinet

Issue 03 (2013-01-15)

Power
Equipmen
t

Wiring
Termi
nal

Color
In
Most
Regio
ns

UK

IBBS200D
(Ver.B)/
IBBS200T
(Ver.B)

EPS01A,
EPS01B,
EPS01C, or
EPS01D

RTN(+)

Red

NEG(-)

Black

IBBS200D
(Ver.C)/
IBBS200T
(Ver.C)

EPU03A-02
,
EPU03A-03
,

RTN(+)

Red

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Cross-Sectional
Area

Exterior

16 mm2 (0.025 in.


2)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

35 mm2 (0.054 in.


2)

The
exterior is
shown by
illustratio
197

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Cabinet

4 IBBS200D Cabinet

Power
Equipmen
t

Wiring
Termi
nal

Color
In
Most
Regio
ns

UK

EPU03A-04
, or
EPU03A-05

NEG(-)

Black

IBBS200D
(Ver.D)/
IBBS200T
(Ver.D)

EPU05A-02
,
EPU05A-03
,
EPU05A-04
, or
EPU05A-05

RTN(+)

Red

Blue

NEG(-)

Black

Gray

IBBS700D/
IBBS700T

ETP48400

RTN(+)

Red

Blue

NEG(-)

Black

Gray

Cross-Sectional
Area

Exterior

n 2 in the
preceding
figure.

35 mm2 (0.054 in.


2), UL3436

The
exterior is
shown by
illustratio
n 3 in the
preceding
figure.

35 mm2 (0.054 in.


2), UL3436

The
exterior is
shown by
illustratio
n 3 in the
preceding
figure.

Power Cable for the Fan in an IBBS200D


The power cables feed power into the fans in an IBBS200D. The power cables include input
power cables and power transfer cables.

Input Power Cable for the Fan in an IBBS200D


Exterior
The input power cables vary according to the types of IBBS200Ds where the fan mounting
frames are installed. The following figure shows the exteriors of the input power cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

198

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Figure 4-43 Exteriors of input power cables for the fan in an IBBS200D

(1) Tool-less female connector (pressfit type)

(2) OT terminal (M4)

(3) EPC4 or EPC6 connector

Description
The following table describes the input power cables.
Table 4-21 Input power cable for the fan in an IBBS200D
Base
Station
Type

Cabinet

BTS3900
A (Ver.B)

IBBS200D
(Ver.B)

BTS3900
A (Ver.C)

BTS3900
A (Ver.D)

Issue 03 (2013-01-15)

IBBS200D
(Ver.C)

IBBS200D
(Ver.D)

Wirin
g
Termi
nal

Color
Most
Region
s

UK

RTN
(+)

Black

NEG(-)

Blue

RTN
(+)

Black

Blue

NEG(-)

Blue

Gray

RTN
(+)

Black

Blue

NEG(-)

Blue

Gray

CrossSectional
Area

Exterior

2.5 mm2 (0.004


in.2)

The exterior is
shown by
illustration 1 in
the preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

The exterior is
shown by
illustration 1 in
the preceding
figure.
The exterior is
shown by
illustration 2 in
the preceding
figure.
199

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Power Transfer Cable for the Fan in an IBBS200D


Exterior
Power transfer cables vary according to the types of cabinets where the fan mounting frames are
installed. The following figures show the exteriors of power transfer cables.
Figure 4-44 Exterior of a power transfer cable for the fan in an IBBS200D

(1) 3V3 connector

(2) OT terminal (M6)

(3) OT terminal (M4)

Description
The following table describes the power transfer cables.
Table 4-22 Power transfer cables for the fans in IBBS200Ds

Issue 03 (2013-01-15)

Base
Station
Type

Cabinet

BTS3900
A
(Ver.B)
BTS3900
A
(Ver.C)

IBBS200D
(Ver.B)
IBBS200D
(Ver.C)

Wire

RTN
(+)

Color
Most
Regio
ns

UK

Black

Blue

CrossSectional
Area

Exterior

l OT
terminal
(M4), 1.5
mm2
(0.002 in.
2)

The exterior is shown


in illustration 1 in the
above figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

200

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

BTS3900
A
(Ver.D)

Cabinet

IBBS200D
(Ver.D)

Wire

4 IBBS200D Cabinet

Color

CrossSectional
Area

Most
Regio
ns

UK

NEG
(-)

Blue

Gray

l OT
terminal
(M6), 6
mm2
(0.009 in.
2)

RTN
(+)

Black

Blue

2.5 mm2
(0.004 in.2)

NEG
(-)

Blue

Gray

Exterior

The exterior is shown


in illustration 2 in the
above figure.

Power Cable for the Heating Film


A power cable for the heating film connects the AC junction box in an APM30H to the AC
junction box for the heating film in an IBBS200D. Then the AC junction box distributes power
to the heating film.

Exterior
The following figure shows the exterior of a power cable for the heating film.
Figure 4-45 Exterior of a power cable for the heating film

(1) OT terminal (M4) on the APM30H side

(2) OT terminal (M4) on the IBBS200D side

Description
The power cable for the heating film, whose cross-sectional area is 1.5 mm2 (0.002 in.2), is
wrapped in a black jacket and has a blue wire and a brown wire.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

201

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

NOTE

The colors and structures of cables delivered by Huawei vary according to countries and regions. If cables
are purchased locally, the cables must comply with local rules and regulations.

4.5.6 Signal Cables


This section describes the exteriors, functions, pin assignment of all signal cables in the
IBBS200D.

ELU Signal Cable


An electronic label unit (ELU) signal cable transmits the cabinet type to a monitoring board in
the cabinet.

Exterior
The following figure shows the exterior of an ELU signal cable.
Figure 4-46 Exterior of an ELU signal cable

(1) RJ45 connector

Description
The following table describes an ELU signal cable.
Table 4-23 ELU signal cable

Issue 03 (2013-01-15)

X1 End

X2 End

Color

Wire Type

X1.1

X2.1

White

Twisted pair

X1.2

X2.2

Orange

X1.3

X2.3

White

X1.6

X2.6

Green

X1.5

X2.5

White

X1.4

X2.4

Blue

X1.7

X2.7

White

X1.8

X2.8

Brown

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Twisted pair

Twisted pair

Twisted pair

202

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Monitoring Signal Cable for the Door Status Sensor


A monitoring signal cable for the door status sensor is used to inform the monitoring board of
the door status that is obtained from the door status sensor. Cabinets configured with door status
sensors are as follows: APM30H, TMC11H, RFC, IBBS200D, IBBS200T, BTS3900AL, OMB,
IBBS700D and IBBS700T.

Exterior
Monitoring signal cables for door status sensors are classified into three types according to the
cabinets being monitored. Figure 4-47, Figure 4-48, and Figure 4-49 show their exteriors.
Figure 4-47 Exterior of a monitoring signal cable for the door status sensor (1)

Figure 4-48 Exterior of a monitoring signal cable for the door status sensor (2)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

203

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

NOTE

l Cable 1 has a 2-pin straight socket at one end, which is connected to the HPMI. Cable 1 has a bare wire
and a cord end terminal at the other end, which are connected to a door status sensor and a cable terminal
block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has a cord end
terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to the two ports
on one side of the cable terminal block.

Figure 4-49 Exterior of a monitoring signal cable for the door status sensor (3)

NOTE

l Cable 1 has a 2-pin straight socket at one end, which is connected to the GATE port on the PMU. Cable
1 has a bare wire and a cord end terminal at the other end, which are connected to a door status sensor
and a cable terminal block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has a cord end
terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to the two ports
on one side of the cable terminal block.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

204

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Description
Monitoring signal cables for door status sensors are classified into different types according to
the monitoring boards to which the door status is reported. The following table lists the
monitoring signal cables for door status sensors.
Table 4-24 Types of monitoring signal cables for door status sensors
Base Station
Type

Cabinet

Monitoring Board
to Which the Door
Status Is Reported

Exterior

BTS3900A
(Ver.B)

l RFC (Ver.B)

CMUA

The exterior is shown


in Figure 4-47.

l TMC11H (Ver.B)
l IBBS200D
(Ver.B) or
IBBS200T (Ver.B)
l RFC (Ver.C)

BTS3900A
(Ver.C)

CMUE

l TMC11H (Ver.C)
l IBBS200D
(Ver.C) or
IBBS200T (Ver.C)
l RFC (Ver.D)

BTS3900A
(Ver.D)

CMUEA

l TMC11H (Ver.D)
l IBBS200D
(Ver.D) or
IBBS200T
(Ver.D)
l IBBS700D

DBS3900

IBBS700T

CMUF

l TMC11H (Ver.B)

CMUA

l IBBS200D
(Ver.B) or
IBBS200T (Ver.B)
l TMC11H (Ver.C)

CMUE

l IBBS200D
(Ver.C) or
IBBS200T (Ver.C)
l TMC11H (Ver.D)

CMUEA

l IBBS200D
(Ver.D) or
IBBS200T
(Ver.D)
l BTS3900C

OMB

HEUA

l DBS3900
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

205

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Base Station
Type

Cabinet

Monitoring Board
to Which the Door
Status Is Reported

l BTS3900C
(Ver.C)

OMB (Ver.C)

HEUB

l BTS3900AL
(Ver.A)

CCU

Exterior

l DBS3900
(Ver.C)
BTS3900AL
(Ver.A)

l IBBS700D
l IBBS700T
l BTS3900A
(Ver.B)

APM30H (Ver.B)

HPMI

APM30H (Ver.C)

HPMI

APM30H (Ver.D)

PMU

The exterior is shown


in Figure 4-48.

l DBS3900
l BTS3900A
(Ver.C)
l DBS3900
l BTS3900A
(Ver.D)

The exterior is shown


in Figure 4-49.

l DBS3900

Monitoring Signal Cable for the Battery Cabinet


A monitoring signal cable for the battery cabinet reports the monitoring signals to the PMU.

Exterior
The following figure shows the exterior of a monitoring signal cable for the battery cabinet.
Figure 4-50 Exterior of a monitoring signal cable for the battery cabinet

(1) RJ45 connector

Description
The following table describes a monitoring signal cable for the battery cabinet.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

206

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

4 IBBS200D Cabinet

Table 4-25 Monitoring signal cable for the battery cabinet

Issue 03 (2013-01-15)

X1 End

X2 End

Color

Wire Type

X1.1

X2.1

White

Twisted pair

X1.2

X2.2

Orange

X1.3

X2.3

White

X1.6

X2.6

Green

X1.5

X2.5

White

X1.4

X2.4

Blue

X1.7

X2.7

White

X1.8

X2.8

Brown

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Twisted pair

Twisted pair

Twisted pair

207

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

IBBS200T Cabinet

About This Chapter


This chapter describes the IBBS200T cabinet exterior, engineering specifications, application
scenarios, as well as boards, modules, and cables in the IBBS200T cabinet.
5.1 Cabinet Exterior
The IBBS200T is an outdoor battery cabinet with a TEC. The IBBS200T can provide backup
power for the APM30H.
5.2 Cabinet Engineering Specifications
This section describes the engineering specifications of the IBBS200T, including the electrical
specifications, equipment specifications, and environment specifications.
5.3 Cabinet Interior
This section describes the components and boards in the IBBS200T. The power distribution
equipment is installed on the upper right wall of the cabinet interior, and the monitoring
equipment is installed inside the cabinet door.
5.4 IBBS200T Components
This section describes the mandatory and optional components in an IBBS200T.
5.5 IBBS200T Cables
The IBBS200T cables consist of the power cables, equipotential cables, PGND cables, and signal
cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

208

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

5.1 Cabinet Exterior


The IBBS200T is an outdoor battery cabinet with a TEC. The IBBS200T can provide backup
power for the APM30H.
The housing material of the IBBS200T uses aluminum board. The surface is covered with acrylic
orange-figured paint to protect the IBBS200T from the damage caused by the solar radiation,
corrosion, moist heat, and mold. The following figure shows the exterior of the IBBS200T.
Figure 5-1 Exterior of the IBBS200T

5.2 Cabinet Engineering Specifications


This section describes the engineering specifications of the IBBS200T, including the electrical
specifications, equipment specifications, and environment specifications.

Electrical Specifications
The following table lists the electrical specifications of the IBBS200T.
Table 5-1 Electrical specifications

Issue 03 (2013-01-15)

Item

Specifications

Input voltage range

-38.4 V DC to -57 V DC

Maximum capacity of the


storage batteries

48 V, 184 Ah

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

209

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Item

Specifications

Cooling capability

l When the ambient temperature is equal to or less than


45oC (113oF), the temperature at the air return vent for
inner circulation of the cabinet is equal to or less than
35oC (95oF).
l When the ambient temperature is equal to 50oC
(122oF) or between 45oC (113oF) and 50oC (122oF), the
temperature at the air return vent for inner circulation
of the cabinet is equal to or less than 45oC (113oF).

Equipment Specifications
The following table lists the equipment specifications of the IBBS200T.
Table 5-2 Equipment specifications
Item

Specifications

Remarks

Dimensions (H x
W x D)

Cabinet (without the base): 700


mm x 600 mm x 480 mm (27.56 in.
x 23.62 in. x 18.90 in.)

Base: 200 mm x 600 mm x 434 mm


(7.87 in. x 23.62 in. x 17.09 in.)
Cabinet weight

45 kg (99.23 lb)

The cabinet is configured only


with monitoring boards, power
distribution box, and cables.

Weight of storage
batteries

12 V 92 Ah storage battery: 33.5


kg (73.87 lb)

The total capacity can expand to 48


V 184 Ah (two 48 V 92 Ah battery
packs).

NOTE
Storage batteries from different
manufacturers have different
specifications. The specifications
listed above are for the commonly
used storage batteries.

Method of
installation

It can be installed on the ground. It


can be also installed on the
TMC11H or APM30H in stack
mode.

In stack mode, the IBBS200T must


be installed under the TMC11H or
APM30H.

Environment Specifications
The IBBS200T can be used outdoors. The following table lists the environment specifications
of the IBBS200T.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

210

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Table 5-3 Environment specifications


Paramete
r

Specifications

Remarks

Operating
temperatur
e

-20oC to +50oC (-4oF to +122oF)

When the temperature is higher than


50oC (122oF), a sun shield is required.

Relative
humidity

5% RH to 100% RH

Altitude

-60 m to +4000 m (-196.85 ft to


+13123.2 ft)

From the altitude of 1800 m (5905.44


ft), the maximum operating
temperature drops by 1oC (33.8oF)
each time the altitude increases by 220
m (721.78 ft).

Wind
speed

67 m/s

Storage
temperatur
e

-40oC to +70oC (-40oF to +158oF)

Dustproof
and
waterproof

IP55

Noise

Meeting the ETS 300 753 4.1E


standard (rural area)

5.3 Cabinet Interior


This section describes the components and boards in the IBBS200T. The power distribution
equipment is installed on the upper right wall of the cabinet interior, and the monitoring
equipment is installed inside the cabinet door.
To improve the cooling efficiency of the TEC, the coverage of the heat insulation foam must be
greater than 75% on the inner side of the IBBS200T. The following figure shows the interior of
the IBBS200T.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

211

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-2 Interior of the IBBS200T

The following table describes the components in the IBBS200D.


Table 5-4 Components in the IBBS200T

Issue 03 (2013-01-15)

N
o.

Compone
nt

Option
al or
Manda
tory

Max
imu
m
Qua
ntit
y in
a
Sin
gle
Cab
inet

Remarks

TEC

Mandat
ory

The TEC ensures the normal operation of the


IBBS200T in high-temperature areas and dissipates
heat from the storage batteries.

CMUEA

Mandat
ory

The central monitoring unit type EA (CMUEA)


controls temperature, detects Boolean alarm, and
identifies the ELU.

ELU

Mandat
ory

The electronic label unit (ELU) reports the cabinet


type automatically to facilitate troubleshooting.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

212

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

N
o.

Compone
nt

Option
al or
Manda
tory

Max
imu
m
Qua
ntit
y in
a
Sin
gle
Cab
inet

Remarks

Storage
battery

Mandat
ory

The storage batteries provide long-duration backup


power for base stations.

Power
distributio
n box

Mandat
ory

The power distribution box is installed on the upper


right wall of the cabinet interior. It transfers and
distributes power to the fan or TEC and storage
batteries.

Door status
sensor

Mandat
ory

The door status sensor monitors the status (open or


closed) of the cabinet door.

NOTE

For the position of the temperature sensor for the storage batteries, see section "Temperature Sensor for
the Storage Batteries" in BTS3900A Hardware Description.

5.4 IBBS200T Components


This section describes the mandatory and optional components in an IBBS200T.

5.4.1 TEC
A TEC dissipates heat for the storage batteries and ensures the normal operation of an IBBS200T
in high-temperature areas.

Exterior
The following figure shows the exterior of a TEC.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

213

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-3 Exterior of a TEC

(1) Outer air circulation fan

(2) Inner air circulation fan

Function
A TEC performs the following functions:
l

If there is a sun shield, and the ambient temperature is 500oC (122oF) without solar
radiation, the TEC ensures that the temperature is equal to or less than 40oC (104oF) in the
cabinet when storage batteries are in float charge and equal to or less than 45oC (113oF)
when the storage batteries are in boost charge.

If there is no sun shield, and the ambient temperature is 50oC (122oF) with solar radiation
of 1120 W/m2, the TEC ensures that the temperature in the cabinet is equal to or less than
45oC (113oF) when storage batteries are in float charge and equal to or less than 50oC
(122oF) when the storage batteries are in boost charge.

If the ambient temperature is 32oC (89.6oF) and there is no temperature difference between
the air intake vent at the hot and cold sides of the TEC, the refrigeration power of the TEC
is equal to or more than 190 W10% and the COP is equal to or more than 0.5.

5.4.2 CMUEA
The central monitoring unit type EA (CMUEA) monitors the fans, Heater Assembly Unit, and
cabinet temperature. A CMUEA can be used in the AMP30H, RFC, TMC11H, IBBS200D,
IBBS200T, or IBBS700D cabinet.

Exterior
The following figure shows the exterior of a CMUEA.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

214

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-4 Exterior of a CMUEA

Ports
The following figure shows the ports on a CMUEA.
Figure 5-5 Ports on a CMUEA

The following table lists information about ports on a CMUEA.


Table 5-5 Ports on a CMUEA

Issue 03 (2013-01-15)

No
.

Silkscreen
on the
Panel

Description

(1)

TEMP2

Reserved port, connected to the temperature sensor.

(2)

WATER

Connected to the water sensor.

(3)

IFAN4

(4)

IFAN3

Connected to the inner air circulation to receive alarms related to the


inner air circulation.

(5)

IFAN2

(6)

IFAN1

(7)

TEC

Connected to the TEC cooler to receive alarms related to the TEC cooler.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

215

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

No
.

Silkscreen
on the
Panel

Description

(8)

TEMP1

l In an RFC, this port is connected to the temperature sensor at the air


intake vent of the cabinet to receive temperature alarms about the
RFC.
l In an IBBS200D, IBBS200T, IBBS700D, or IBBS700T, this port is
connected to the battery temperature sensor to receive alarm signals
about the battery temperature.

(9)

COM_OUT

It is an RS485 signal port, which communicates with lower-level


cascading ports and reports monitoring information.
l In the APM30H, this port is connected to the PMU.
l In an RFC, TMC11H, IBBS200D, IBBS200T, IBBS700D, or
IBBS700T, this port is connected to a lower-level CMUEA.

(10
)

COM_IN

RS485 signal port for communicating with upper-level cascading ports


and reporting monitoring information.
l In the APM30H, this port is connected to the BBU.
l In the RFC or TMC11H, this port is connected to the BBU or an
upper-level CMUEA.
l In an IBBS200D, IBBS200T, IBBS700D, or IBBS700T, this port is
connected to the PMU or an upper-level CMUEA.

(11
)

ELU

Port for connecting the ELU to report the cabinet type.

(12
)

GATE

Boolean signal port, which is connected to the door status sensor.

(13
)

IN0, IN1,
and IN2

Boolean signal port.


l In the APM30H, RFC, TMC11H, IBBS200D, or IBBS200T, these
ports are reserved.
l In the IBBS700D or IBBS700T, IN0 is connected to the heater, and
IN1 and IN2 are reserved.

(14
)

SMOKE

Boolean signal port.


l In the APM30H, RFC, TMC11H, IBBS200D, or IBBS200T, this
port is connected to the smoke sensor.
l In the IBBS700D or IBBS700T, this port is not involved.

Issue 03 (2013-01-15)

(15
)

EFAN1

(16
)

EFAN2

(17
)

PWR

Connected to the outer air circulation fan to receive its alarm signals.

Power input port providing DC power input for the board.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

216

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Indicators
The two indicators on the CMUEA panel indicate the status of the CMUEA. The following table
describes their meanings.
Table 5-6 Indicators on the CMUEA panel
Silkscr
een

Color

State

Meaning

RUN

Green

Blinking (on for 1s and


off for 1s)

The board is functional and communicating


with the BBU properly.

Blinking (on for 0.125s


and off for 0.125s)

The board is functional but fails to


communicate with the BBU or the board is
not registered.

Steady on

The board is in the power-on self-check


status.

Steady off

There is no power supply, or the board is


faulty.

Steady off

No alarm is reported.

Steady on

An alarm is generated, and the board must be


replaced.

Blinking (on for 1s and


off for 1s)

An alarm is generated, and the alarm may be


caused by an associated board or port fault.
Therefore, you need to locate the fault before
determining whether to replace the board.

ALM

Red

DIP Switch
On the CMUEA, there is a DIP switch J18, which is used to set the working mode of the CMUEA
according to the cabinet type. Figure 5-6 shows the position of the DIP switch on the CMUEA.
Figure 5-6 Position of DIP switch on a CMUEA

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

217

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

In different types of cabinets, DIP switches on the CMUEA are set in different ways, as shown
in Figure 5-7.
NOTE

The white boxes indicate the positions of all bits in the DIP switch.

Figure 5-7 DIP switch setting on the CMUEA in different cabinets

5.4.3 Power Distribution Box


The power distribution box is installed on the upper right inner wall of the cabinet, which controls
the two storage battery groups separately and the DC power supply to the fan or TEC.

Exterior
The following figure shows the exterior of a power distribution box.
Figure 5-8 Exterior of a power distribution box

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

218

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Port
The following table describes the ports on a power distribution box.
Table 5-7 Ports on the power distribution box
No.

Silkscreen

Meaning

Description

(1)

BAT

Input power
cable port for
storage batteries

It supports a one-hole OT terminal (M8)


installed on a cable with a cross-sectional area
of 35 mm2 (0.054 in.2).

(2)

BAT_SW0

Circuit breaker
for the upper
storage batteries

It controls the power supply to upper storage


batteries in the cabinet. The circuit breaker
requires 250 A current.

(3)

FAN/
TEC_OUTPU
T

Power output
port for a fan or
TEC

It supports EPC4 connectors and requires 30 A


current.

(4)

BAT_SW1

Circuit breaker
for the lower
storage batteries

It controls the power supply to lower storage


batteries in the cabinet. The circuit breaker
requires 250 A current.

(5)

BAT

Input power
cable port for
storage batteries

It supports a one-hole OT terminal (M8)


installed on a cable with a cross-sectional area
of 35 mm2 (0.054 in.2).

(6)

FAN/
TEC_INPUT

Power input port


for a fan or TEC

It supports EPC4 connectors and requires 30 A


current.

Wire
The following figure shows the input and output power cables for a power distribution box.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

219

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-9 Cables for a power distribution box

(1) RTN(+) cable for upper storage (2) Power transfer cable for a TEC or (3) NEG(-) wire for lower storage
batteries
fan assembly
batteries
(4) NEG(-) wire for upper storage
batteries

(5) RTN(+) wire for lower storage


batteries

5.4.4 Storage Battery


Storage batteries is the store power equipment.
NOTE

Storage batteries from different manufacturers differ in exteriors and technical specifications. In this section, a
12 V 92 Ah storage battery is described as an example.

Exterior
The following figure shows the exterior of a 12 V 92 Ah storage battery.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

220

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-10 Exterior of a 12 V 92 Ah storage battery

Configuration
The IBBS200T and IBBS200D support two types of storage battery groups: 48 V 92 Ah and 48
V 184 Ah.
l

Two 48 V 92 Ah storage battery groups are connected in parallel and serve as a 48 V 184
Ah storage battery group.

Each group consists of four storage batteries.

Technical Specifications
The following table describes the technical specifications of a 12 V 92 Ah storage battery.
Table 5-8 Technical specifications of a 12 V 92 Ah storage battery
Storage Battery Type

Dimensions (H x W x D)

Weight

12 V, 92 Ah

105 mm x 287 mm x 390 mm


(11.30 in. x 4.13 in. x 15.35
in.)

33.5 kg (73.85 lb)

108 mm x 287 mm x 393 mm


(11.30 in. x 4.25 in. x 15.47
in.)

35 kg (77.16 lb)

5.4.5 ELU
An electronic label unit (ELU) reports the cabinet type automatically to facilitate
troubleshooting.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

221

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Exterior
The following figure shows the exterior of an ELU.
Figure 5-11 Exterior of an ELU

(1) Shell

(2) RJ45 port

NOTE

The ELU in a BTS3900 or BTS3900L has no shell.

The board collecting information from the ELU varies according to the cabinet, as listed in the
following table.
Table 5-9 Monitoring boards to which an ELU reports information

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Board Collecting
Information from
the ELU

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B) and BTS3900L (Ver.B)

FMUC

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C) and BTS3900L (Ver.C)

FMUE

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D) and BTS3900L (Ver.D)

FMUEA

BTS3900A
(Ver.B)

APM30H (Ver.B), TMC11H (Ver.B), RFC


(Ver.B), IBBS200D (Ver.B), and IBBS200T
(Ver.B)

CMUA

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

222

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Base Station
Type

Cabinet

Board Collecting
Information from
the ELU

BTS3900A
(Ver.C)

APM30H (Ver.C), TMC11H (Ver.C), RFC


(Ver.C), IBBS200D (Ver.C), and IBBS200T
(Ver.C)

CMUE

BTS3900A
(Ver.D)

APM30H (Ver.D), TMC11H(Ver.D), RFC


(Ver.D), IBBS200D(Ver.D), IBBS200T
(Ver.D), and IBBS700D

CMUEA

IBBS700T

CMUF

BTS3900C
(Ver.C)

OMB (Ver.C)

HEUB

BTS3900AL
(Ver.A)

BTS3900AL (Ver.A), IBBS700D, IBBS700T

CCU

Installation Position
Positions of ELUs vary in different cabinets. The following figure shows their positions.
Figure 5-12 Position of the ELU in a BTS3900 cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

223

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-13 Position of the ELU in a BTS3900L cabinet

Figure 5-14 Position of the ELU in an APM30H or IBBS200D cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

224

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

NOTE

An ELU is located on the right inner wall of the APM30H, TMC11H, or RFC, or on the left inner wall of
the IBBS200D or IBBS200T. The preceding figure shows an APM30H and an IBBS200D as an example.

Figure 5-15 Position of the ELU in an OMB

Figure 5-16 Position of the ELU in a BTS3900AL cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

225

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-17 Position of the ELU in a IBBS700D cabinet

NOTE

In the IBBS700D, when the cabinet is configured with a CCU, the ELU is above the CCU. When the cabinet
is not configured with a CCU, the ELU is on the right of the CMUEA.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

226

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-18 Position of the ELU in a IBBS700T cabinet

NOTE

In the IBBS700T, when the cabinet is configured with a CCU, the ELU is above the CCU. When the cabinet
is not configured with a CCU, the ELU is on the left of the CMUF.

5.4.6 Door Status Sensor


A door status sensor reports the status (open or closed) of a door. It is installed in any of the
following cabinets: BTS3900AL, OMB, OMB (Ver.C), APM30H, RFC, TMC11H, IBBS200D,
IBBS200T, IBBS700D, and IBBS700T.

Exterior
A door status sensor consists of a magnet and a switch. The following figures show the exteriors
of them.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

227

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-19 Exterior of the magnet of a door status sensor

(1) Magnetic shell

(2) Magnet

The following figure shows the exterior of the switch of a door status sensor.
Figure 5-20 Exterior of the switch of a door status sensor

Installation Position
Positions of door status sensors vary in different cabinets. The following figure shows their
positions.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

228

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

NOTE

l A door status sensor is installed at the same position in the BTS3900AL (Ver.A), IBBS700D, and
IBBS700T. Figure 5-21 uses the BTS3900AL (Ver.A) as an example.
l A door status sensor is installed at the same position in the OMB and OMB (Ver.C). Figure 5-22 uses
the OMB (Ver.C) as an example.
l A door status sensor is installed at the same position in the following cabinets: APM30H (Ver.B),
APM30H (Ver.C), APM30H (Ver.D), RFC (Ver.B), RFC (Ver.C), RFC (Ver.D), TMC11H (Ver.B),
TMC11H (Ver.C), TMC11H (Ver.D), IBBS200D (Ver.B), IBBS200D (Ver.C), IBBS200D (Ver.D),
IBBS200T (Ver.B), IBBS200T (Ver.C), and IBBS200T (Ver.D). Figure 5-23 uses the APM30H
(Ver.D) as an example.

Figure 5-21 Position of a door status sensor in the BTS3900AL (Ver.A)

Figure 5-22 Position of a door status sensor in the OMB (Ver.C)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

229

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-23 Position of a door status sensor in the APM30H (Ver.D)

5.4.7 Temperature Sensor


The temperature sensor monitors the temperature in the cabinet. It is installed in the following
cabinets: BTS3900AL, RFC, IBBS200T, IBBS200D, OMB, IBBS700T, and IBBS700D.

Exterior
The following figure shows the exterior of a temperature sensor.
Figure 5-24 Exterior of a temperature sensor

(1) Temperature sensor

(2) 4-pin connector

Installation Position
Positions of temperature sensors vary in different cabinets. The following figure shows their
positions.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

230

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

NOTE

l A temperature sensor is installed at the same position in the RFC (Ver.B), RFC (Ver.C), and RFC
(Ver.D). Figure 5-26 uses the RFC (Ver.D) as an example.
l A temperature sensor is installed at the same position in the IBBS200T (Ver.B), IBBS200T (Ver.C),
and IBBS200T (Ver.D). Figure 5-27 uses the IBBS200T (Ver.D) as an example.
l A temperature sensor is installed at the same position in the IBBS200D (Ver.B), IBBS200D (Ver.C),
and IBBS200D (Ver.D). Figure 5-28 uses the IBBS200D (Ver.D) as an example.
l A temperature sensor is installed at the same position in the OMB (Ver.C), and OMB. Figure 5-29
uses the OMB (Ver.C) as an example.

Figure 5-25 Position of the temperature sensor in a BTS3900AL (Ver.A) cabinet

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

231

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-26 Position of the temperature sensor in an RFC (Ver.D)

Figure 5-27 Position of the temperature sensor in an IBBS200T (Ver.D)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

232

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-28 Position of the temperature sensor in an IBBS200D (Ver.D)

Figure 5-29 Position of the temperature sensor in an OMB (Ver.C)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

233

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-30 Position of the temperature sensor in an IBBS700D

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

234

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-31 Position of the temperature sensor in an IBBS700T

Technical Specifications
The following table lists the technical specifications of a temperature sensor.
Table 5-10 Technical specifications of a temperature sensor
Counter

Specification

Operating voltage

3.0 V DC to 5.5 V DC

Temperature measurement range

-55C to +125C (-131 F to +257 F)

Temperature measurement error

2C (35.6F)

5.5 IBBS200T Cables


The IBBS200T cables consist of the power cables, equipotential cables, PGND cables, and signal
cables.

5.5.1 Cable List


IBBS200T cables consist of the PGND cables, equipotential cables, power cables, and signal
cables.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

235

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Power Cables, PGND Cables, and Equipotential Cables


Table 5-11 lists the power cables, PGND cables, and equipotential cables.
Table 5-11 Power cables, PGND cables, and equipotential cables
Classi
ficati
on

Cable

Cables
to be
install
ed
onsite

Cables
install
ed
before
deliver
y

One End

The Other End

Connector

Installation
Position

Connector

Installation
Position

Power Cable
for a Power
Distribution
Box

OT terminal

RTN(+) and
NEG(-)
terminals on
the terminal
block for
storage
batteries on
the EPU

OT terminal

RTN(+) and
NEG(-)
terminals on
the BAT
terminal block
on the power
distribution
box in the
IBBS200T

Storage
Battery Power
Cable

OT terminal

Copper bar on
the power
distribution
box

OT terminal

Storage
battery

TEC Power
Cable

EPC4 or
EPC6
connector

LOAD8 port
on the EPU

EPC4 or
EPC6
connector

FAN/
TEC_INPUT
port on the
power
distribution
box in the
IBBS200T

2.7.3 PGND
Cable

OT terminal

Ground bar in
the cabinet

OT terminal

Ground busbar
outside the
cabinet

2.7.4
Equipotential
Cable

OT terminal

Ground bar in
the upper
cabinet

OT terminal

Ground bar in
the lower
cabinet

NOTE

(1) If there are two IBBS200Ts, connects the power cable for the TEC in the second IBBS200T to the
power distribution box in the first IBBS200T.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

236

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Signal Cables
Table 5-12 describes signal cables.
Table 5-12 Signal cables
Classi
ficati
on

Cable

Cables
to be
install
ed
onsite
Cables
install
ed
before
deliver
y

One End

The Other End

Connecto
r

Installation
Position

Connect
or

Installation
Position

Monitoring
Signal
Cable for
the Battery
Cabinet

RJ45
connector

COM_IN port on
the CMUEA in the
IBBS200D or
IBBS200T

RJ45
connector

COM_485 port on
the PMU

ELU Signal
Cable

RJ45
connector

ELU

RJ45
connector

ELU port on the


CMUEA

Monitoring
Signal
Cable for
the Door
Status
Sensor

2-pin
connector

GATE port on the


CMUEA

Bare wire

Door status sensor

5.5.2 Cable Connections


This section describes the principles for connecting power cables and signal cables in the
IBBS200T.

Power Cable Connections


This section describes the power cable connections in the IBBS200T.
The following figure shows the power cable connections in the IBBS200T.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

237

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-32 Power cable connections in the IBBS200T

(1) Cable between the battery pack and the shortcircuiting copper bar

(2) TEC Power Cable (3) Storage Battery Power Cable

(4) Cable between the battery pack and the shortcircuiting copper bar

(5) TEC Power Cable -

Monitoring Signal Cable Connections


This section provides reference for onsite installation of monitoring signal cables.
Figure 5-33 shows the monitoring signal cable connections in the IBBS200T.
Figure 5-33 Monitoring signal cable connections in the IBBS200T

(1) Monitoring signal cable for the battery (2) ELU signal cable (3) Monitoring signal cable for the door
cabinet
status sensor

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

238

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

5.5.3 PGND Cable


PGND cables ensure that cabinets and internal components are properly grounded and that base
stations run properly. PGND cables include classified into PGND cables for cabinets and PGND
cables for components.

Exterior
The following figure shows the exterior of a PGND cable.
Figure 5-34 Exterior of a PGND cable

(1) One-hole OT terminal

(2) Two-hole OT terminal

NOTE

In most cases, the PGND cable is a yellow and green colored cable. When 110 V dual-live-wire power is
supplied for BTS3900A (Ver.C) and BTS3900A (Ver.D) cabinets, the PGND cables are green.

Description
The cross-sectional areas and maximum lengths of PGND cables vary according to the types of
cabinets. Table 5-13 and Table 5-14 describe PGND cables.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

239

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Table 5-13 PGND cables for cabinets

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B) 15 m (49.21


and BTS3900L
ft)
(Ver.B)

25 mm2
(0.039
in.2)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

One-hole
OT
terminal
(M8)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900A
(Ver.B)

RFC (Ver.B)

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.C)

RFC (Ver.C)

8 m (26.25
ft)

25 mm2
(0.039
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.D)

RFC (Ver.D)

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

BTS3900A
(Ver.D)

IBBS700D and
IBBS700T

5 m (16.4 ft)

35 mm2
(0.054
in.2)

The cable
has a onehole OT
terminal
(M6) on
the
cabinet
side and a
one-hole
OT
terminal
(M8) on
the
ground
bar side.

The exterior
is shown by
illustration
1 in the
preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

240

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900AL
(Ver.A)

BTS3900AL
(Ver.A)

8 m (26.25
ft)

35 mm2
(0.054
in.2)

Select
one of the
followin
g
specificat
ions
based on
the onsite
situation:

The exterior
is shown by
illustration
2 or 3 in the
preceding
figure.

l The
cable
has a
twohole
OT
termi
nal
(M6)
at
each
end,
and
the
distan
ce
betwe
en the
two
holes
of
each
twohole
OT
termi
nal is
15.8
mm
(0.62
in.).
l The
cable
has a
twohole
OT
termi

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

241

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base Station
Type

Cabinet

5 IBBS200T Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

nal
(M6)
on the
cabin
et side
and a
onehole
OT
termi
nal
(M6)
on the
groun
d bar
side.
The
distan
ce
betwe
en the
two
holes
of the
twohole
OT
termi
nal is
15.8
mm
(0.62
in.).
IBBS700D and
IBBS700T

Issue 03 (2013-01-15)

5 m (16.4 ft)

35 mm2
(0.054
in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

The cable
has a onehole OT
terminal
(M6) on
the
cabinet
side and a
one-hole
OT
terminal
(M8) on
the
ground
bar side.

The exterior
is shown by
illustration
1 in the
preceding
figure.

242

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900C
(Ver.C)

OMB (Ver.C)

15 m (49.21
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

DBS3900

APM30H (Ver.B)
series cabinets

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

APM30H (Ver.C)
series cabinets

8 m (26.25
ft)

25 mm2
(0.039
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

APM30H
(Ver.D) series
cabinets

8 m (26.25
ft)

16 mm2
(0.025
in.2)

One-hole
OT
terminal
(M6)

The exterior
is shown by
illustration
1 in the
preceding
figure.

Table 5-14 PGND cables for components

Issue 03 (2013-01-15)

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

BTS3900 (Ver.B)
and BTS3900L
(Ver.B)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

BTS3900 (Ver.C)
and BTS3900L
(Ver.C)

One-hole
OT
terminal
(M4)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

BTS3900 (Ver.D)
and BTS3900L
(Ver.D)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

243

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Base Station
Type

Cabinet

Maximum
Length

CrossSection
al Area

Connect
or

Exterior

BTS3900A
(Ver.B)

APM30H (Ver.B)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M4)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

IBBS200D
(Ver.B)
IBBS200T
(Ver.B)

BTS3900C
(Ver.C)

OMB (Ver.C)

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M6)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

BTS3900AL
(Ver.A)

BTS3900AL

15 m (49.21
ft)

6 mm2
(0.009
in.2)

One-hole
OT
terminal
(M6)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

5.5.4 Equipotential Cable


An equipotential cable connects the PGND terminals of two cabinets. It ensures equipotential
bonding between cabinets and safe operation of base stations.

Exterior
The following figure shows the exterior of an equipotential cable.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

244

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-35 Exterior of an equipotential cable

(1) One-hole OT terminal

(2) Two-hole OT terminal

NOTE

In most cases, the equipotential cable is a green and yellow cable. When 110 V dual-live-wire power is
supplied for the cabinets used by the BTS3900A (Ver.C) or BTS3900A (Ver.D), the equipotential cable
is green.

Description
The following table describes equipotential cables.
Table 5-15 Equipotential cables
Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900
(Ver.B)

16 mm2 (0.025 in.2)

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

16 mm2 (0.025 in.2)

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 2 in the preceding
figure.

BTS3900
(Ver.C)
BTS3900
(Ver.D)
BTS3900A
(Ver.B)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

245

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900A
(Ver.C)

The cross-sectional areas of


cables vary according to the
way that cabinets are
combined.

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

One-hole
OT
terminal
(M6) at
each end

The exterior is shown by


illustration 1 in the preceding
figure.

l 16 mm2 (0.025 in.2) for


stacked cabinets
l 25 mm2 (0.039 in.2) for
side-by-side cabinets
BTS3900A
(Ver.D)

Issue 03 (2013-01-15)

16 mm2 (0.025 in.2)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

246

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Base
Station
Type

Cross-Sectional Area

Connect
or

Exterior

BTS3900AL
(Ver.A)

The cross-sectional areas of


cables vary according to the
way that cabinets are
combined.

l When
a
BTS39
00AL
AC
cabinet
is
combi
ned
with a
BTS39
00AL
DC
cabinet
or an
IBBS7
00D/
IBBS7
00T,
each
end of
the
cable
has a
twohole
OT
termin
al
(M6),
and the
distanc
e
betwee
n the
two
holes
of each
twohole
termin
al is
15.8
mm
(0.62
in.).

The exterior is shown by


illustration 2 or 3 in the
preceding figure.

l When a BTS3900AL AC
cabinet is combined with a
BTS3900AL DC cabinet
or an IBBS700D/
IBBS700T, the crosssectional area of the cable
is 35 mm2 (0.054 in.2)
l When a BTS3900AL AC
cabinet is combined with a
TMC11H (Ver.C), the
cross-sectional area of the
cable is 25 mm2 (0.039in.
2).

l When
a

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

247

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Cross-Sectional Area

5 IBBS200T Cabinet

Connect
or

Exterior

BTS39
00AL
AC
cabinet
is
combi
ned
with a
TMC1
1H
(Ver.C
), the
cable
has a
twohole
OT
termin
al
(M6)
on the
BTS39
00AL
AC
cabinet
side
and a
onehole
OT
termin
al
(M6)
on the
TMC1
1H
(Ver.C
) side.
The
distanc
e
betwee
n the
two
holes
of each
twohole

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

248

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Base
Station
Type

Cross-Sectional Area

5 IBBS200T Cabinet

Connect
or

Exterior

termin
al is
15.8
mm
(0.62
in.).

5.5.5 Power Cables


This section describes the exteriors, functions, and pin assignments of the power cables in the
IBBS200T.

Storage Battery Power Cable


Storage battery power cables connect storage batteries and the power distribution boxes in
battery cabinets. The power cables include groups to wiring copper bars and connect the copper
bars between storage batteries.

Storage Battery Power Cables Between Battery Groups and Wiring Copper Bars
The following figure shows the exteriors of the power cables.
Figure 5-36 Exteriors of storage battery power cables between battery groups and wiring copper
bars

(1) OT terminal (M8)

Issue 03 (2013-01-15)

(2) OT terminal (M6)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

249

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

The following table describes the storage battery power cables between battery groups and
wiring copper bars.
Table 5-16 Storage battery power cables between battery groups and wiring copper bars
Power Equipment

Wire

Color

Cross-Sectional
Area

Exterior

EPU03A-02 or
EPU03A-04,
EPU05A-02 or
EPU05A-04, and
ETP48400

RTN
(+)

Red

35 mm2 (0.054 in.


2)

NEG
(-)

Black

The exterior is shown


by illustration 1 in the
preceding figure.
When the power
equipment is
EPU05A-02,
EPU05A-04, or
ETP48400 in UK, the
RTN(+) wire is blue and
the NEG(-) wire is gray.

EPS01A or EPS01C

RTN
(+)

Red

16 mm2 (0.025 in.


2)

NEG
(-)

Black

The exterior is shown


by illustration 2 in the
preceding figure.

Copper Bars Between Storage Batteries


Copper bars are delivered with the storage batteries. The following figure shows the exterior of
a copper bar.
Figure 5-37 Exterior of a copper bar between storage batteries

Power Cable for a Power Distribution Box


A power cable for a power distribution box connects the power system to the power distribution
box in a battery cabinets, which are IBBS200D, IBBS200T, IBBS700D, and IBBS700T, and
provide input power to batteries in these cabinets.

Exterior
Power cables for power distribution boxes vary according to the power equipment. The following
figure shows the exteriors of the power cables.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

250

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-38 Exteriors of power cables for power distribution boxes

(1) Power series 120 connector (2) OT terminal (M6) (3) Power series 175 connector (4) OT terminal (M8)

Description
The following table describes the power cables for power distribution boxes.
Table 5-17 Power cables for power distribution boxes
Cabinet

Issue 03 (2013-01-15)

Power
Equipmen
t

Wiring
Termi
nal

Color
In
Most
Regio
ns

UK

IBBS200D
(Ver.B)/
IBBS200T
(Ver.B)

EPS01A,
EPS01B,
EPS01C, or
EPS01D

RTN(+)

Red

NEG(-)

Black

IBBS200D
(Ver.C)/
IBBS200T
(Ver.C)

EPU03A-02
,
EPU03A-03
,

RTN(+)

Red

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Cross-Sectional
Area

Exterior

16 mm2 (0.025 in.


2)

The
exterior is
shown by
illustratio
n 1 in the
preceding
figure.

35 mm2 (0.054 in.


2)

The
exterior is
shown by
illustratio
251

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

Cabinet

5 IBBS200T Cabinet

Power
Equipmen
t

Wiring
Termi
nal

Color
In
Most
Regio
ns

UK

EPU03A-04
, or
EPU03A-05

NEG(-)

Black

IBBS200D
(Ver.D)/
IBBS200T
(Ver.D)

EPU05A-02
,
EPU05A-03
,
EPU05A-04
, or
EPU05A-05

RTN(+)

Red

Blue

NEG(-)

Black

Gray

IBBS700D/
IBBS700T

ETP48400

RTN(+)

Red

Blue

NEG(-)

Black

Gray

Cross-Sectional
Area

Exterior

n 2 in the
preceding
figure.

35 mm2 (0.054 in.


2), UL3436

The
exterior is
shown by
illustratio
n 3 in the
preceding
figure.

35 mm2 (0.054 in.


2), UL3436

The
exterior is
shown by
illustratio
n 3 in the
preceding
figure.

TEC Power Cable


A thermoelectric cooler (TEC) power cable feeds power into a TEC.

TEC Power Cable


Exterior
The following figure shows two types of TEC power cables classified by the power equipment.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

252

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-39 Exteriors of TEC power cables

(1) Tool-less female connector (pressfit type)

(2) OT terminal (M4)

(3) EPC4 or EPC6 connector

Description
The following table describes TEC power cables.
Table 5-18 TEC power cables
Power
Equipment

Wire

EPS01A or
EPS01C and
EPU03A-02 or
EPU03A-04
EPU05A-02 or
EPU05A-04

Color
Most
Region
s

UK

RTN(+)

Black

Blue

NEG(-)

Blue

Gray

RTN(+)

Black

Blue

NEG(-)

Blue

Gray

CrossSectional
Area

Exterior

2.5 mm2
(0.004 in.2)

The exterior is shown by


illustration 1 in the
preceding figure.
The exterior is shown by
illustration 2 in the
preceding figure.

TEC Power Transfer Cable


Exterior
The following figure shows two types of TEC power transfer cables classified by the power
equipment.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

253

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Figure 5-40 Exteriors of TEC power transfer cables

(1) 3V3 connector

(2) OT terminal (M6)

(3) OT terminal (M4)

Description
The following table describes TEC power transfer cables.
Table 5-19 TEC power transfer cables

Issue 03 (2013-01-15)

Power
Equipment

Wire

EPS 01A or
EPS 01C and
EPU03A-02 or
EPU03A-04

EPU05A-02 or
EPU05A-04

Color
Most
Region
s

UK

RTN
(+)

Black

Blue

NEG
(-)

Blue

Gray

RTN
(+)

Black

Blue

NEG
(-)

Blue

Gray

CrossSectional Area

Exterior

l OT terminal
(M4), 1.5
mm2 (0.002
in.2)
l OT terminal
(M6), 6 mm2
(0.009 in.2)

The exterior is shown


by illustration 1 in the
preceding figure.

2.5 mm2 (0.004


in.2)

The exterior is shown


by illustration 2 in the
preceding figure.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

254

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

5.5.6 Signal Cables


This section describes the exteriors, functions, pin assignment of all signal cables in the
IBBS200T.

ELU Signal Cable


An electronic label unit (ELU) signal cable transmits the cabinet type to a monitoring board in
the cabinet.

Exterior
The following figure shows the exterior of an ELU signal cable.
Figure 5-41 Exterior of an ELU signal cable

(1) RJ45 connector

Description
The following table describes an ELU signal cable.
Table 5-20 ELU signal cable

Issue 03 (2013-01-15)

X1 End

X2 End

Color

Wire Type

X1.1

X2.1

White

Twisted pair

X1.2

X2.2

Orange

X1.3

X2.3

White

X1.6

X2.6

Green

X1.5

X2.5

White

X1.4

X2.4

Blue

X1.7

X2.7

White

X1.8

X2.8

Brown

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Twisted pair

Twisted pair

Twisted pair

255

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Monitoring Signal Cable for the Door Status Sensor


A monitoring signal cable for the door status sensor is used to inform the monitoring board of
the door status that is obtained from the door status sensor. Cabinets configured with door status
sensors are as follows: APM30H, TMC11H, RFC, IBBS200D, IBBS200T, BTS3900AL, OMB,
IBBS700D and IBBS700T.

Exterior
Monitoring signal cables for door status sensors are classified into three types according to the
cabinets being monitored. Figure 5-42, Figure 5-43, and Figure 5-44 show their exteriors.
Figure 5-42 Exterior of a monitoring signal cable for the door status sensor (1)

Figure 5-43 Exterior of a monitoring signal cable for the door status sensor (2)

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

256

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

NOTE

l Cable 1 has a 2-pin straight socket at one end, which is connected to the HPMI. Cable 1 has a bare wire
and a cord end terminal at the other end, which are connected to a door status sensor and a cable terminal
block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has a cord end
terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to the two ports
on one side of the cable terminal block.

Figure 5-44 Exterior of a monitoring signal cable for the door status sensor (3)

NOTE

l Cable 1 has a 2-pin straight socket at one end, which is connected to the GATE port on the PMU. Cable
1 has a bare wire and a cord end terminal at the other end, which are connected to a door status sensor
and a cable terminal block, respectively.
l Cable 2 has a bare wire at one end, which is connected to a door status sensor. Cable 2 has a cord end
terminal at the other end, which is connected to a cable terminal block.
l Cable 3 has a cord end terminal at each end. The two cord end terminals are connected to the two ports
on one side of the cable terminal block.

Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

257

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Description
Monitoring signal cables for door status sensors are classified into different types according to
the monitoring boards to which the door status is reported. The following table lists the
monitoring signal cables for door status sensors.
Table 5-21 Types of monitoring signal cables for door status sensors
Base Station
Type

Cabinet

Monitoring Board
to Which the Door
Status Is Reported

Exterior

BTS3900A
(Ver.B)

l RFC (Ver.B)

CMUA

The exterior is shown


in Figure 5-42.

l TMC11H (Ver.B)
l IBBS200D
(Ver.B) or
IBBS200T (Ver.B)
l RFC (Ver.C)

BTS3900A
(Ver.C)

CMUE

l TMC11H (Ver.C)
l IBBS200D
(Ver.C) or
IBBS200T (Ver.C)
l RFC (Ver.D)

BTS3900A
(Ver.D)

CMUEA

l TMC11H (Ver.D)
l IBBS200D
(Ver.D) or
IBBS200T
(Ver.D)
l IBBS700D

DBS3900

IBBS700T

CMUF

l TMC11H (Ver.B)

CMUA

l IBBS200D
(Ver.B) or
IBBS200T (Ver.B)
l TMC11H (Ver.C)

CMUE

l IBBS200D
(Ver.C) or
IBBS200T (Ver.C)
l TMC11H (Ver.D)

CMUEA

l IBBS200D
(Ver.D) or
IBBS200T
(Ver.D)
l BTS3900C

OMB

HEUA

l DBS3900
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

258

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Base Station
Type

Cabinet

Monitoring Board
to Which the Door
Status Is Reported

l BTS3900C
(Ver.C)

OMB (Ver.C)

HEUB

l BTS3900AL
(Ver.A)

CCU

Exterior

l DBS3900
(Ver.C)
BTS3900AL
(Ver.A)

l IBBS700D
l IBBS700T
l BTS3900A
(Ver.B)

APM30H (Ver.B)

HPMI

APM30H (Ver.C)

HPMI

APM30H (Ver.D)

PMU

The exterior is shown


in Figure 5-43.

l DBS3900
l BTS3900A
(Ver.C)
l DBS3900
l BTS3900A
(Ver.D)

The exterior is shown


in Figure 5-44.

l DBS3900

Monitoring Signal Cable for the Battery Cabinet


A monitoring signal cable for the battery cabinet reports the monitoring signals to the PMU.

Exterior
The following figure shows the exterior of a monitoring signal cable for the battery cabinet.
Figure 5-45 Exterior of a monitoring signal cable for the battery cabinet

(1) RJ45 connector

Description
The following table describes a monitoring signal cable for the battery cabinet.
Issue 03 (2013-01-15)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

259

APM30H&TMC11H&IBBS200D&IBBS200T (Ver.D)
Product Description

5 IBBS200T Cabinet

Table 5-22 Monitoring signal cable for the battery cabinet

Issue 03 (2013-01-15)

X1 End

X2 End

Color

Wire Type

X1.1

X2.1

White

Twisted pair

X1.2

X2.2

Orange

X1.3

X2.3

White

X1.6

X2.6

Green

X1.5

X2.5

White

X1.4

X2.4

Blue

X1.7

X2.7

White

X1.8

X2.8

Brown

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Twisted pair

Twisted pair

Twisted pair