Powered Medical Examination Table
Model 7000
Installation & Operation Manual
Important Information.............................................2
Safety Information..................................................3
Component Identification.......................................3
Specifications.........................................................4
Electrical Requirements.........................................4
Installation..............................................................5
Operation...............................................................8
Table Adjustments..................................................9
Maintenance.........................................................15
Limited Warranty..................................................16
IMPORTANT INFORMATION
General
Service
The power examination table is primarily used in examination rooms for general examinations and minor procedures. The wide variety of positions provided by four
powered motions, adjustable legrest, adjustable headrest, Date of Purchase
stirrups and treatment pan, create a safe and convenient
Serial Number
patient positioning table for most examinations and procedures performed in the doctors office.
Model Number
The table is easily adjusted to a wide variety of positions
using the convenient foot control provided with the table.
An optional hand pendant may be purchased which can
be used in conjunction with the foot control. The table
height can be adjusted from 19 to 40. The table seating
surface can be moved from the normal horizontal position
to an angle of 30. The backrest can be adjusted from a
flat lying down position, to an 85 angle for seating. The
legrest can be adjusted from a vertical position for seating, to a horizontal position for laying.
Authorized
Dealer Name
Dealer
Phone Number
Dealer Address
SAFETY INFORMATION
Safety Information
CAUTION indicates an imminently or potential hazardous situation which, if not avoided, may
result in serious injury and/or equipment damage.
COMPONENT IDENTIFICATION
Headrest (adjustable)
Headrest Linkage
Assembly
Seat
(adjustable angle)
Backrest
(adjustable angle)
Treatment
Pan
Stirrups
Leg Section
(adjustable angle)
Foot Control
SPECIFICATIONS
Weight of Table......................................................550 lbs.
Load Rating (maximum):
Seat/Back..............................................................450 lbs.
Legrest (Flat & Kneeling).......................................450 lbs.
Headrest................................................................100 lbs.
Back Section Range................0 (horizontal) to +85 5
Table Top Height Range............19 0.5 in. to 40 1.0 in.
Leg Section Range.............0 (horizontal) to 90 (vertical)
Table Top
Tilt Range................. 0 (horizontal) to +30 5 (foot up)
Dimensions:
Upholstered Headrest..................13 in. wide x 11 in. high
Upholstered Top.....................28.0 in. wide x 44.5 in. long
Upholstered
Leg Rest .....16.5 in. wide x 11.25 in. high
Overall Length...................................................69 in. long
With Headrest/
Footrest Extended.............................................90 in. long
Electrical Requirements
..................115 VAC nominal, 60 HZ, 5.8 amps maximum
Fuse rating.....................................................250V /2.5AT
ELECTRICAL REQUIREMENTS
WARNING
When performing a cauterization or similar treatment, the patient must be insulated from the metal
portions of the table by nonconductive material.
Failure to do so may result in electrical shock or
burns to the patient.
WARNING
CAUTION
CAUTION
WARNING
Do not use this table in an explosive or oxygenenriched atmosphere. Failure to do so may result
in serious personnel injury or death.
INSTALLATION
Overview
Uncrating
Leveling the Base
Installing the Foot Control
Installing the Upholstery
Uncrating
NOTE: Inspect all boxes and contents for damage. Report any damage to the carrier immediately.
CAUTION
To avoid damaging the tables upholstery or painted surfaces, DO NOT use a knife or other sharp
object to open the packaging. Also, to avoid damaging the table lift only at points indicated in Figure
3. Do not lift at other points as indicated in Figures
3 and 4.
1. Using a 1/2 open-end wrench, or socket, unbolt the
table from the wooden shipping skid by removing the
four bolts located underneath the tables base; two on
each side.
WARNING
Do Not Lift
Figure 4. Stirrups and Treatment Pan
INSTALLATION (CONTINUED)
Leveling the Table
The upholstery set includes: Headrest shroud and cushion, Seat/Back cushion, and Legrest cushion.
Headrest Shroud and Cushion
1. Raise the back so the top of the headrest is at a comfortable work height.
2. Align the holes in the headrest cushion, shroud, and
headrest mounting link. Make sure cushion is properly centered on the shroud. Fasten with the four
screws provided.
Seat/Back Cushion
1. Refer to the Operation section in this manual and
position the table so the seat, back and legrest are
flat (in the horizontal position). (Figure 7)
2. Place the seat/back cushion on the table with the
curved end toward the headrest and the straight end
facing the legrest (Figure 8). Adjust the cushion so
that the straight end overhangs the seat frame by approximately 4.
Legrest Cushion
1. Position legrest in the horizontal position. Raise the
table to its fullest height.
2. Align the holes in the legrest cushion and legrest
plate, then fasten with the four screws provided.
Headrest Shroud
Legrest Cushion
Headrest Cushion
Seat/Back Cushion
Frame
Curved End
Straight End
Slots
Mounting Holes
Seat Frame
Slots
Mounting Holes
Figure 8.
OPERATION
General
DANGER
WARNING
NOTE: The table is not designed for continuous operation. The control system includes a thermal overload
safety switch to protect from overheating. If the table is
operated continuously causing the control to exceed its
allowable operating temperature, the thermal overload
safety switch will shut off. If normal operation ceases, do
not attempt to operate the table. Allow the table to cool
for 10-15 minutes before attempting to use again. The
thermal overload switch will automatically reset when it
has reached a safe operating temperature.
WARNING
Do not use this table in an explosive or oxygenrich atmosphere. To do so will result in an explosion or fire.
If the table malfunctions, immediately remove your
hand or foot from the controls, unplug the power
cord from the electrical receptacle, and assist the
patient from the table. If table continues to malfunction, call for service. Do not attempt to repair
table yourself.
Before initiating power, keep personnel and equipment clear of the table movement to avoid personal injury or equipment damage.
CAUTION
WARNING
Keep personnel and equipment clear of table before initiating movement to avoid personal injury
or damage to the equipment.
NOTE: Each control function will automatically stop moving when either the UP or DOWN travel limit is reached.
If the button is pressed with travel at its limit, the actuator will not run. Sensors prevent the actuator motor from
operating when travel limit has been reached, preventing
wear of the actuator.
CAUTION
BACK UP
Raises Back
BACK DOWN
Lowers Back
TILT UP
Raises the front of the
seat, tilting the entire
table top upward
TILT DOWN
Lowers the front of the
seat, tilting the entire
table top downward
LEGREST UP
Raises Legrest
LEGREST DOWN
Lowers Legrest
TABLE UP
Raises the entire table
upward
TABLE DOWN
Lowers the entire table
downward
TABLE ADJUSTMENTS
Table Height (Figure 10)
The back can be adjusted to any angle between horizontal and 85.
1. To adjust the back from a chair (upright) position to a
horizontal position, depress and hold the Back/Down
pedal until the desired angle is achieved, then release
the pedal.
2. To adjust the backrest from a horizontal position to a
chair (upright) position, depress and hold the Back/Up
pedal until the desired angle is achieved, then release
the pedal.
10
CAUTION
11
Lift up over-center
1
2
Figure 16. Legrest Kneeling Position
12
WARNING
13
WARNING
Treatment
Pan
Tray
Upper Handle
(Locked)
Headrest Handle
(Locked)
WARNING
14
Lower Handle
(Locked)
Figure 22. Headrest Handles
MAINTENANCE
Preventative Maintenance
Table Care
CAUTION
CAUTION
The upholstery material is resistant to most medicinal type stains, but may be damaged by solvents
and dyes. Remove any spilled fluids from the upholstery immediately.
Clean the table weekly, wiping the painted metal and
plastic surfaces with a clean, soft cloth. If desired, mild
cleaners may be used.
Fuse Replacement
WARNING
Fuse
15