Agenda
1. Precision
2. Simple
3. Flexible
4. Energy savings
5. Summary
extra References
1. Precision
Precision
What is PICV?
Two in one
Simple setting
Perfect balance
Perfect control
Cost saving
Compact design
Precision
valve
Precision
Precision
Conclusion:
Constant p across the control valve, resulting in accurate
flow limitation and 100% authority.
Precision
designconcept B
A (example AB-QM)
PICV conceptdesign
Facts:
Long stroke
limiting
the stroke
No 100%
100%
authority
authority
at each
eachsetting
setting
Precision
PICV concept A
PICV concept B
M
10V
10V
0V
0V
Precision
Uitleg:
-100% autoriteit
-door verkorten van slaglengte
Precision
Availibility
Types till 10
Control flow from 0.8 GPM till 1232 GPM
New !
1/2
- 1
1/2-
8
8 10
10
1 4
4
5
5 6
6
2. Simple
Simple
Selection
Selection is dependent only on the flow
No calculation
2
66 GPM
07/10/2010
13
Simple
Setting / Selection
Calculate the setting:
Q
Qmaximum
Design
_____________
X 100%
(AB(AB-QM)
Example:
Design = 2.4 GPM
valve,
max flow = 4 GPM
Simple
Setting / selection
Calculation:
2.4/4 x 100% =
60%
Simple:
In the whole range setting
is done on percentage !
Simple
Simple
Calculation
Flow = Cv p
No Cv calculations needed !
Simple
A=
p open valve
p closed valve
(x 100%)
Simple
Terminal Unit
Simple
Simple
Simple
pressures
Simple
Simple
So
So:: More stable
roomtemperatures and a
longer actuator life span.
3. Flexible
Flexible
PICV applications
Fancoil unit cooling heating
Flexible
PICV applications
AHU cooling/heating
cooling/heating
4. Energy savings
Energy Savings
Savings
Efficient
production of
heat/cool
Efficient pumping
Efficient temperture
control
Energy Savings
Variable flow
Dynamic flow
limitation
5%
25%
Better temperature
control allow higher
average temperature
thus decrease total
energy usage
40%
30%
Chiller
Fans
Pumps
Other
Energy Savings
Ashrae Article
Facts*:
Most (80%) of complaint are of thermal sensation nature.
In average 20% of maintenance cost are due to solving those complaints.
According to survey made on 280 th m2, with 7.500 occupants there were 2300
complaints out of which 1650 were thermal sensation caused by poor control
performance and HVAC faults. In average 1,8 hours of maintenance work was
spend for one complaint, meaning almost 3.000 man hours per year in this
particular case 20% of all energy costs.
*Extracts from article: Predicting the Frequency and Cost of Hot and Cold Complaints in
Buildings,Clifford C. Federspiel, Ph.D., Associate Member ASHRAE
Energy Savings
mean temperature
A
Better control means
less possibility for claim
Energy Savings
Number of complaints
Bad
Good
Air Temp In
Coil Water
Temp
In & Out
Diagnostic Logger
Data logger
water
sensor
air
sensor
data
logger
FCU /
AHU
AB-QM
FCU /
AHU
Savings
5. Summary
Summary
1. Precision
100% authority at each flow(setting)
Accurate at low
2. Simple
Easy selection
No calculation on kv and authority needed.
Only setting the flow
3. Flexible
For each application we have a sollution
4. Energy savings
With PICV can be saved on energy, so money
6. References
AB-QM References
South Danish
University, Denmark
Sea Towers Gdynia,
UMKC Student Union Building,
Poland
Rabobank HQ,
The Netherlands
Questions?