= 8,7 are
Figure 62. The results for the data acquired from the C3P1T5 and C3P1T3 sensors
Figure 63. The results for the data acquired from the C3P4T1 and C3P1T2 sensors
The colours symbolism is the same as for the previous method. It is evident
that just by adding the log-likelihood ratio, a change detection method still can be
fooled. In the case of the data gathered from the C3P4T1 sensor, the performance
is worse than for the Page Hinkley Test.
Detailed results will be presented in the comparative table.
The Generalized Likelihood Ratio [43] [46] is similar to the DCS, as it takes
into account the changes in the signal, but over a whole time interval (thus utilizing
a sliding window). It also maximizes the amplitude of the changes, in order to gain
more sensitivity. Only the maximum of the supremum value attained by the sum
is compared with the threshold, in order to detect fires.
The sum computed on an interval is
( )=
ln
49
( )
( )
( 78 )