www.commscope.com
Contents
1. OVERVIEW
3
3
4
5
6
2.1
2.2
2.3
2.4
2.5
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
7
7
8
8
10
11
12
13
14
14
14
15
15
Administration
Subsystem
Horizontal
Subsystem
Coverage Area
Subsystem
Riser/Backbone
Subsystem
Equipment
Room
Subsystem
Campus
Subsystem
www.commscope.com
BAS
Controller/
BAS
Outstation
Controller/
Outstation
BAS
Device
BAS
Device
BAS
Outlet
BAS
Outlet
Horizontal Cable
Horizontal Cable
Maximum Horizontal Distance = 90 m
BAS
Outlet
BAS
Outlet
BAS
Devices
BAS
Devices
BAS Channel
BAS Channel
Outlet
Cable
Daisychain
4-Wire Fault
Tolerant
Point-to-point
www.commscope.com
Cross-connect
Device
Outlet
Cable
Daisychain
4-Wire Fault
Tolerant
Point-to-point
Branch 1
Remote
Bridge
One Pair
of Wires
Branch N-1
Bridge
Trunk
Trunk
4-Pair
Cable
Cable Pairs
Branch 1
Branch N-1
Administration
of Chained
Branches
Device/Node
Branch N
(N=10 max)
Branch Length
www.commscope.com
BAS
Devices
BAS
Devices
To Next
Device or
EOLR To Next
Device or
EOLR
EOLR To next
Device or
EOLR
Bridged
Connection
Bridged
Connection
Multipoint Bus
Multipoint Bus
www.commscope.com
Device 2
2-Wire Bus
L1
L2
From
Previous
Device or
Controller
To Other
Devices or
EOLR
L3
L4
The length of
L1, L2, L3 and L4
is typically less
than 14 m.
Device 3
Device 4
www.commscope.com
One Pair
of Wires
Circuit Length
Figure 9: 4-Wire Fault-Tolerant Circuit
www.commscope.com
Coverage Area
(sq meter)
Additional Factors
Office
25
Indoor Parking
50
Retail
25
Factory
50
Hotel
25
Classroom
25
Hospital
25
Mechanical Room
Note: These values are based on support for 3 BAS categories (e.g FLS, security and HVAC) averaged over the
entire floor space since BAS devices will be located in all areas (including stairways, hallways, lobby, elevators
and other common areas). Coverage area size depends on the BAS application and device.
www.commscope.com
25 C
1.5
3.36
55 C
0.75
1.68
www.commscope.com
Max. Current in
Each Wire (A)
Maximum
Recommended
Fusing (A)
1.5
2.0
2.0*
1.5
0.825
1.65
3.36
1.0
0.55
1.1
3.36
0.75
0.4125
0.825
3.36
0.5
* An unused capacity of 1.3 A can be distributed over the other six conductors in this 4-pair cable.
Note: BAS cabling are designed to operate with power sources that are power limited and supply a maximum of
24-AWG circuit current of 1.5 A. If a power source is not inherently limited to 1 A, additional current limiting must
be provided. This is the recommended practice for current limiting.
www.commscope.com
Max. Permitted AC
Voltage - Peak
(Non-sinusoidal)
Max. Permitted DC
Voltage
(Continuous)
Max. Permitted DC
Voltage - Peak
(Interrupted at
10 Hz to 200 Hz)
30
42.2
60
24.8
Maximum circuit
power 100 VA1
1
Max. Permitted AC
Voltage - Peak
(Non-sinusoidal)
Max. Permitted DC
Voltage
(Continuous)
Max. Permitted DC
Voltage - Peak
(Interrupted at
10 Hz to 200 Hz)
15
21.2
30
12.4
Maximum circuit
power 100 VA1
1
2
10
53
20
106
30
160
40
213
50
266
60
320
70
373
80
426
90
480
100
533
www.commscope.com 10
For 12 V Minimum
at Device
(50% V Drop =
12 V)
For 18 V
Minimum at
Device
(25% V Drop)
For 21.6 V
Minimum at
Device
(10% V Drop)
For 22.8 V
Minimum at
Device(5% V
Drop)
10
6401
3219
1288
643
20
3219
1609
643
322
30
2146
1073
429
215
40
1609
805
322
161
50
1286
643
258
129
60
1073
536
215
107
70
920
456
182
91
80
792
402
161
80
90
701
354
139
69
100
643
320
129
64
200
322
160
64
32
500
129
64
26
13
1000
64
32
13
www.commscope.com 11
30 m
100 m
305 m
610 m
1000 m
1524 m
0.001
0.002
0.006
0.019
0.057
0.114
0.188
0.286
0.0014
0.003
0.008
0.026
0.080
0.160
0.263
0.400
0.005
0.009
0.028
0.094
0.286
0.572
0.938
1.430
0.010
0.019
0.056
0.188
0.572
1.145
1.877
2.860
0.014
0.026
0.079
0.263
0.801
1.603
2.627
4.000
0.020
0.038
0.113
0.375
1.145
2.289
3.753
5.720
0.030
0.056
0.169
0.563
1.717
3.434
5.630
8.580
0.042
0.079
0.236
0.788
2.404
4.808
7.882
12.012
0.050
0.094
0.282
0.938
2.862
5.724
9.383
14.300
0.084
0.158
0.473
1.576
4.808
9.616
15.760
11.447
0.100
0.188
0.563
1.877
5.724
0.200
0.375
1.126
3.753
11.447
0.300
0.563
1.689
5.630
17.171
0.400
0.751
2.252
7.506
0.500
0.938
2.815
9.383
0.600
1.126
3.378
11.260
0.700
1.314
3.941
13.136
0.800
1.501
4.504
15.013
0.900
1.689
5.067
16.889
1.000
1.877
5.630
www.commscope.com 12
Device Current
Draw (mA)*
For 12 V
Minimum
at Device
(50% V Drop =
12 V)
For 18 V
Minimum at
Device
(25% V Drop)
For 20.4 V
Minimum at
Device
(15% V Drop)
For 21.6 V
Minimum at
Device
(10% V Drop)
For 22.8 V
Minimum at
Device
(5% V Drop)
30
183
183
183
183
183
50
183
183
183
183
128
80
183
183
183
160
79
100
183
183
183
128
64
150
183
183
125
85
42
4-Pair
Cable
4-Pair
Cable
PTC/
Fuses
110/VisiPatch
Wiring Block
Crossconnect
Wire
24 VAC
Ain
Equipment
Equipment
www.commscope.com 13
Screw Terminal
Wire-Insert Screw-Down
Crimp-On Pin
Wire-Insert Spring-Pressure
Crimp-On Pin
Pigtail Leads
www.commscope.com 14
positive signal
-S
ground
+AC
positive power
-AC
W-BL
BL
W-O
W-G
W-BR
BR
Pin
Controller
Communication Port
+S
-S
A-IN
+AC
-AC
4-20 mA
A-OUT
+24
POWER
D-IN
S1
G1
S2
G2
D-OUT
S1
G1
S2
G2
www.commscope.com 15
W-BL
BL
W-O
W-G
W-BR
BR
Pin
Data 0 (Clock)
Data 1 (Card
Information)
LED
+ Power
Ground
Door Strike
Common
Pair 3
Pair 2
1 2
Pair 1
4 5
Pair 4
Jack Position
Figure 11: ANSI/EIA/TIA Figure
T568B11:
pin
assignment
ANSI/EIA/TIA
T568B pin assignment
www.commscope.com
Visit our Web site or contact your local
CommScope representative for more information.
2011 CommScope, Inc. All rights reserved.
All trademarks identified by or are registered trademarks
or trademarks, respectively, of CommScope, Inc.
This document is for planning purposes only and is not
intended to modify or supplement any specifications or
warranties relating to CommScope products or services.
MI-94
07/11