General
This manual is a guide to the installation and operation of the VID-HUB-16P model VIDIPAC UTP.
Please read the entire manual before installing.
Brief description
VID-HUB-16P model is a 16-channel passive transceiver hub with RJ45 and Terminal block UTP cable connection. This passive
hub has built-in transient protection and excellent anti-interference ability. VID-HUB-16P Passive Hub allows upto 16 CCTV
video signals to be transmitted via cost-effective Unshielded Twisted Pair (UTP) cable. Used with passive transceivers, the UTP
CCTV passive transceiver hub can connect the CCTV security and surveillance equipments using standard structured cabling
techniques for neater and more streamlined cabling instead of costly and bulky coaxial cable.
VID-HUB-16P also works in conjunction with other VIDIPAC passive transceivers and passive hubs.
Features of VID-HUB-16P
PAL, NTSC, SECOM video compatible
16-channel Passive device, no power required
Transmission range: Colour signal up to 225m* working with passive
transceivers
Terminal block UTP cable connection
BNC female video connectors
Transient protection and excellent anti-interference ability
LED video signal indicators for each channel
One year warranty
Technical specifications
Model
Video
Cable Type
Bandwidth
DC-6MHz
Insertion Loss
0.5dB
CMMR
Anti-transient Ability
6000V 1.2S50S
Coaxial Cable
75ohm
Coaxial Connector
UTP Connection
Specification*
Resistance
100ohm20
DC Loop Resistance
18ohm/100m
Differential Capacitance
62pf/m
Temperature
Operating: -20 to 70 C
Humidity
0~95%
Environmental
Humidity
Mechanical
Vidipac VID-HUB-16P
Weight
Dimensions - overall of
Mechanical:balun
0~95%
1.25kg
Mechanical Drawing
Mechanical Drawing
Installation
Installation
Caution
Unshielded Twisted Pair (UTP) wires must be used. Note: Shielded twisted pair wires cause impedance mismatch
Make sure there are no untwisted wires as it may result in distorted image and interference.
Each video signal must use the same twisted pair.
Make sure there are no extra branch (or star connection) of twisted pair as it results in ghost image. Always connect the
transceivers with point-to-point Unshielded Twisted Pair wires.
Coaxial cable length between the video equipment and the passive UTP transceiver balun must not exceed 1.8m.
Transceiver installation
Connect the VID-HUB-16P passive transceivers hub as close as possible through the coaxial cable to the video equipments
(Camera, monitors, VCRs, DVRs, etc.)
VID-HUB-16P passive transceiver hub has RJ45 and terminal block marked + and - for 4-video signals.
Use a pair of Unshielded Twisted Pair (UTP) wires to connect single video signal.
Make sure the + of one transceiver is connected to the + of another transceiver and vice versa for the - terminal.
There are 4 sets of RJ45 and terminal block connectors for 16-video channels.
Video Indicator LEDs - Optional function
Rating: 12Vdc 200mA. This passive hub has optional video present indicator LEDs. If this function is required then connect
a 12Vdc PSU (500mA or larger ok) to the 12Vdc input on rear of hub. Centre is Positive and outer is Negative. LED ON =
Video Present. Note that this passive hub is not supplied with a PSU. Whether this function is used or not does not affect the
operation of this passive hub.
Make RJ45
RJ45 connection
connection according
according to
to the
the figure
figure below
below and
and insert
insert it
it into
into
Make
the
the RJ45
RJ45 socket
socket on
on the
the front
front panel
panel of
of the
the transceiver
transceiver hub
hub
Connection Diagram
Connection Diagram
Receiver
Distance
Antiinference
Power
Supply
Floating
YES
NO
NO
Surge
Protection
VID-Hub-16P
Transceiver
VID-Hub-04P
Receiver
VID-Hub-08P
VID-Hub-16P
Up to 225m
Distance
Antiinterference
VID-02P
Up to 225m
VID-03P
Up to 225m
Troubleshooting
VID-HUB No Signal on the Monitor. Make sure
VID-HUB-16P
Up to 225m
04P
YES
Terminal are well connected
VID--HubVID-HUB-16P
Same pair of08P
UTP wire is used Up to 225m
Twisted image. Make Sure
VID--HubVID-HUB-16P
Up vice
to 225m
+ terminal is16P
connected to + and
versa for -
Power
Supply
YES
Floating
Surge
Protection
NO
YES
VID-HUB-16P
VID-HUB-16P
NO
The video image is somewhat red and a red bar moves downward. Make sure
BNC connector is well connected
Equipments are well grounded
Troubleshooting
The video is not stable and has ghost effect. Make sure
No Signal on the Monitor. Make sure
There are no extra branch (or star connection) from the twisted pair
Terminal are well connected
A single length UTP wire is used
Same pair of UTP wire is used
Noisy image. Make sure
There are no untwisted UTP wires to avoid interference
Twisted image. Make Sure
Attenuated image. Make sure
+
terminal
Coax length
is less
than 1.8m is connected to + and vice versa for -
UTP length is less than 225m
The
video
Distortedimage.
Make
sure image is somewhat red and a red bar moves downward.
Make
sure
To use
UTP wires
Cat3 upwards to avoid impedance mismatch.
Page 5