Você está na página 1de 36

P r o d u c t

c a t a l o g u e

2007 - 2008

4-5
1

6-7

8-9

10-11

12-15

16-17
2

18-19
THERMOBILE production plant, Breda, The Netherlands.

20-21

During the past 40 years Thermobile Industries BV has specialized in the


Development, Production and International Sales and Marketing of space
heaters. The head office is situated in Breda, The Netherlands (photo 1).
In addition to the distribution through Thermobiles own sales and service
offices in the Netherlands, Germany, France, the United Kingdom and the
United States the products are also distributed through a worldwide network of
dedicated partners.

23

The Thermobile products are produced with great care and they are
extensively tested. A permanent quality control system, according to
ISO 9001:2000, is part of the production process (photo 2-6).

24

Naturally, all Thermobile heaters comply with the most stringent European
certification standards and they carry the well-known markings of CE, GASTEC
and/or CSA/UL and GOST.

25

THERMOBILE INDUSTRIES BV

THERMOBILE DEUTSCHLAND GmbH

Konijnenberg 80, 4825 BD Breda, The Netherlands


Postbus 3312, 4800 DH Breda, The Netherlands
Company number 3502
Phone (076) 587 34 50, Fax (076) 587 27 89
e-mail: info@thermobile.com internet: www.thermobile.com

Siemensring 44 Q
47877 Willich - Germany
Tel. (0)2154 88 99 15, Fax (0)2154 88 99 71
e-mail: info@thermobile.de internet: www.thermobile.de

26-27

THERMOBILE FRANCE sarl

THERMOBILE UK LTD
12, Buckingham Close
Bermuda Industrial Estate
Nuneaton, Warwickshire
CV10 7JT, United Kingdom
Phone 02476 35 79 60, Fax 02476 35 79 69
e-mail: info@thermobile.co.uk internet:
www.thermobile.co.uk

28-29

3, rue Denis Papin


45240 LA FERT ST. AUBIN
France
Phone 02 38 76 59 25, Fax 02 38 76 58 93
e-mail: info@thermobile.fr internet: www.thermobile.fr

THERMOBILE NORTH AMERICA

22

PO Box 403, 535 West Wall Street


Darien, WI 53114
USA
Phone (262)882-4203, Fax (262) 882-4202
Nextel: 110*531111*24
e-mail: info@thermobile.us internet: www.thermobile.us

30-35

36
Member of

the Honing Beheer Group of Companies

T/TA/TAS Direct oil fired

ITA/ITAS Oil fired with flue connection

IMA Oil fired with flue connection and separate external burner

IMAC Oil fired with flue connection (containerised)

G/GA/GA V Direct propane fired


MS Modulating control units

AGA Direct natural gas / propane fired

TAS 800 E Direct oil fired with large air throw

AT Cabinet used oil fired with flue connection


and built-in fuel tank

BioEnergy Rapeseed oil / linseed oil fired with flue


connection and built in tank

PROHEAT Cabinet oil fired with flue connection


and built-in fuel tank

COOLSPACE Air coolers

PRODRY Dehumidifiers

BX/CH/VTB/ProHeat 18 Electric heaters

VAL Infra-red radiant oil fired

Accessories Recirculation fans


Service testing equipment

Dimensions and weights

diesel/heating oil

paraffin

propane

natural gas

electric

used oil

Rapeseed oil

T/TA/TAS Direct oil fired

T 80 / TA 80

T 40 / TA 40

Air wheels are optional.

T 16 / TA 16
Portable model (wheel set optional)

T 22 / TA 22

TAS 80, suspended model


without fuel tank and wheels.

Tank heating (optional).

Working principle
Safe cool outside housing.
High pressure pump for diesel or paraffin.

heat with 100% efficiency.


Direct
outlet temperature circa 450C.
Fixed
Fast temperature rise.

1-Way pipe system prevents fuel disturbance.

Tank for 15 hours burning duration (except


models T/TA 16).

Advantages of THERMOBILE T/TA/TAS series:

Very mobile. Economic in use. Reliable.


FEATURES

Durable phospated body parts with powder coating.


Exchangeable components.
T models with manual on/off switch.
TA models with burner relay, photocell flame control and thermostat connection.
TAS models without fuel tank and wheel set, with hooks for suspension and return type fuel pump to be
connected to suction and return fuel hoses.
Air wheels for T/TA 16/22/40/80 available as accessory.
High pressure pump with 1-way pipe system. Conversion kit to 2-way pipe system available for connection
to bulk tank (max. length 50 m/height 3 m, depends on diameter of pipe).
Room ventilation is required.

APPLICATIONS

AGRICULTURE

Heating of sheds, and workshops.


Drying of agricultural products.

HORTICULTURE

Heating of greenhouses and polytunnels.


(N.B. Only use paraffin and control CO2 emission).
INDUSTRY

Heating of factories and transit sheds, defrosting of pipework and installations.


MOTOR TRADE

General workshop heating.

TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL

PART
NUMBER

HEAT OUTPUT
Btu/hr
kW
kcal/hr

T 16
40.236.000
64.000
18,6
T 22
40.233.000
88.000
25
T 40
40.403.100
160.000
46
T 80
40.803.100
320.000
93
TA 16
40.237.000
64.000
18,6
TA 22
40.223.000
88.000
25
TA 40
40.404.100
160.000
46
TA 80
40.804.100
320.000
93
TAS 16
40.239.000
64.000
18,6
TAS 40
40.407.100
160.000
46
TAS 80
40.807.100
320.000
93
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr
SEE PAGE 30-35 FOR ACCESSORIES

16.000
22.000
40.000
80.000
16.000
22.000
40.000
80.000
16.000
40.000
80.000
1 KG/hr=1,2L/hr

APPROX. FUEL
CONS. OIL
L/hr
KG/hr
1,8
2,5
4,5
9,0
1,8
2,5
4,5
9,0
1,8
4,5
9,0

1,5
2,1
3,7
7,5
1,5
2,1
3,7
7,5
1,5
3,7
7,5

HEATED
AIR FLOW
M3/hr
600
600
1.200
2150
600
600
1.200
2.150
600
1200
2150

TANK
CAPACITY
LITRES
16
40
80
160
16
40
80
160
-

POWER
CONSUMPTION
230V (AMPS)
1,1
1,0
2,1
3,6
1,1
0,6
1,8
3,5
1,0
1,8
3,5

THERMOSTAT
CONNECTION
YES
YES
YES
YES
YES
YES
YES

ITA/ITAS Oil fired with flue connection

W
NE
ITA 45

ITA 75

ITA 30
For recirculation fans see page 32

Air wheels are optional.

Tank heating (optional).

New burner chamber.


Thermobile achieves
optimum coverage with the
unique combination of stainless
steel and high-temperature proof
steel for the burner chamber and
heat exchanger.

ITAS 75, suspended model


without fuel tank and wheels.

Working principle

High pressure pump for diesel or paraffin.


Combustion chamber heat resistant up to 850C.

Clean and dry heat.


100%
Fixed outlet temperature circa 100 120C.

1-Way pipe system prevents fuel disturbance.


Tank for 16 hours burning duration.
20% more than competitors.

Advantages of THERMOBILE ITA series:

Clean heat. Heat distribution is possible. Mobility with fuel tank.


FEATURES

Durable phosphated body panels with powder coating.


With burner relay, photocell flame control, overheat protection and thermostat connection.
ITAS models without fuel tank and wheel set, with hooks for suspension and return type fuel pump to be
connected to suction and return fuel hose.
High pressure pump with 1-way pipe system. Conversion kit to 2-way pipe system available for connection
to bulk tank (max. length 50 m/height 3m, depends on diameter of pipe).
Room ventilation is required.

APPLICATIONS

AGRICULTURE

Heating stables, sheds and workshops.


Drying of agricultural products.
Storing flower bulbs without risk of harmful ethylene emission.

HORTICULTURE

Heating of greenhouses and polytunnels without risk of harmful CO2 emission.


Heating sorting areas.
BUILDING INDUSTRY

Heating and drying of building locations and all-weather projects.


Heating of transit sheds, workshops and warehouses.
workshops and body preparation areas.
Heating
Spray booth heating.
ITA models are especially suited for heating marquees, showrooms and sports halls.
INDUSTRY

MOTOR TRADE

MARQUEES HEATING

TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL

PART
NUMBER

HEAT OUTPUT
Btu/hr
kW

ITA 30
41.300.000
86.000
ITA 45
41.404.000 167.000
ITA 75
41.750.000 239.000
ITAS 30
41.301.000
86.000
ITAS 45
41.407.000 167.000
ITAS 75
41.751.000 278.000
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr

kcal/hr

APPROX. FUEL
CONS. OIL
L/hr
KG/hr

24,8
21.000
2,4
2,0
45,1
42.000
4,6
3,8
70,0
60.000
7,7
5,8
24,8
21.000
2,4
2,0
48,4
42.000
4,6
5,8
70,0
70.000
7,7
6,4
1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr

HEATED
AIR FLOW
M3/hr

MAXIMAL
VENTILATOR
BACK PRESSURE

TANK
POWER
CAPACITY CONSUMPTION
LITRES
230V (AMPS)

OUTLET
CONE
MM

1.100
2.700
3.800
1.100
3.800
3.800

100
200
200
100
200
200

40
80
120
-

300
150
YES
400
150
YES
400
180
YES
300
150
YES
400
150-160
YES
400
180
YES
SEE PAGE 30-35 FOR ACCESSORIES

1,2
3,3
4,0
1,2
3,3
4,0

FLUE
CONNECTION THERMOSTAT
MM
CONNECTION

IMA Oil fired with flue connection and separate external

IMA 185 Axial

Fork truck slots available.

IMA 111 Axial

Tigerloop standard.

IMA 61/111 can pass through a door


width of 80 cm.

IMA 61 Axial

Air wheels are optional.

MULTITANKS, for use in


combination with IMA.

Working principle
High efficiency heat exchanger (92%).
Combustion chamber heat resistant up to 850C.
Radial fan for powerful heat distribution.

Clean and dry heat.


100%
temperature circa 50 80C.
Outlet
Large heat throw.

Protection bars all around.

Big wheels.

Lower tray for oil containment


during servicing.

Propane gas model on request.

Advantages of THERMOBILE IMA series:

High capacity. Easily transportable. Compact..


FEATURES

Durable phosphated body panels with powder coating.


With overheating protection and temperature limitation of warm air.
Preheating of chamber, so that no cold air is blown during start up.
Fully automatic, controllable with thermostat connection.
Fuel filter with condensate separator.
Tigerloop standard.
Burner with rain cover and lower tray for oil containment during servicing.
Room ventilation is required, fresh air connection available.
Available with 2 fan types:
axial
: standard fan
radial HP
: High Pressure for extra high pressure (500 Pa) and air flow.
Radial fans are essential for heat distribution with hoses.

burner

IMA 185 Radial

IMA 111 Radial

IMA 61 Radial

APPLICATIONS
BUILDING INDUSTRY

and drying of building sites and all-weather


Heating
projects.
MARQUEE HEATING

models are especially suited for heating marquees,


IMA
showrooms and sports halls.
9

INDUSTRY

Heating of transit sheds and workshops.


of sheds and storage areas.
Heating
of agricultural products.
Drying
Storing bulbs without the risk of harmful ethylene
emission.
AGRICULTURE

HORTICULTURE

of greenhouses and polytunnels without the


Heating
risk of harmful CO emission.
2

MOTOR TRADE

workshops and body preparation areas.


Heating
Spray booth heating.

Recirculatiionset IMA.

MULTITANKS, maximum storage capacity at minimum dimensions, for storing


domestic oil (consult local regulations).

TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL

PART
NUMBER

GROSS OUTPUT
Btu/hr
kW

IMA 61 axial
41.722.000 22.5000 65
IMA 61 radial
41.722.300 22.5000 65
IMA 111 axial
41.724.000 38.5000 111
IMA 111 radial
41.724.207 38.5000 111
IMA 111 radial HP
41.724.210 38.5000 111
IMA 185 axial
41.728.200 64.1000 185
IMA 185 radial HP
41.728.010 64.1000 185
IMA 185 radiaal 230V 41.728.650 64.1000 185
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr

kcal/hr

APPROX. FUEL
CONS. OIL
L/hr
KG/hr

56.000
6,5
56.000
6,5
96.000
10,9
96.000
10,9
96.000
10,9
160.000
18,4
160.000
18,4
16.0000
18,4
1 KG/hr=1,2L/hr

5,4
5,4
9,1
9,1
9,1
15,3
15,3
15,3

HEATED
AIR FLOW
M3/hr
3.100
4.500
6.400
8.000
11.500
9.700
15.000
10.000

MAX. BACK
PRESSURE OF FAN
Pa
150
250
150
300
500
150
500
300

POWER
CONSUMPTION
(AMPS)
2,8/230V
6,1/230V
4,1/230V
9,2/230V
7,7/400V
7,2/230V
10,4/400V
14/230V

OUTLET
CONE
MM

FLUE
CONNECTION
MM

THERMOSTAT
CONNECTION

400
180
YES
400
180
YES
500
200
YES
500
200
YES
500
200
YES
600
200
YES
600
200
YES
600
200
YES
SEE PAGE 30-35 FOR ACCESSORIES

IMAC Oil fired with flue connection (containerised)


Interactive CD-rom
presentation

IMAC 4000 E

IMAC 2000 E

IMAC 2000S

Working principle
High efficiency heat exchanger (92%).
Weather resistant and lockable casing.
High Pressure fan for powerful heat distribution.
Recirculation hose flange possible.

Clean and dry heat.


100%
Outlet
temperature circa 40 70C.
Large heat
throw.

Combustion chamber heat resistant up to 850C.


Lower tray for oil containment during servicing.

10

Propane gas model on request.

Advantages of THERMOBILE IMAC series:

High capacity.

Easily and safely transportable. Central control.

FEATURES

Stackable construction with crane hooks.


Body work in stainless steel.
Standard with stainless steel frame on box girders with fork truck slots and lifting hooks.
Lockable door panels for control box and burner area with feed through glands for cable and fuel hoses.
Intercal industrial burner with flow control.
Completely automatic burner control with thermostat connection.
With overheat protection and temperature limitation of warm air.
Fan and thermal security resettable from control box.
Removable outlet flanges 300/500 or 600 mm (recirculation hose flange available as accessory).
Multi-functional warm air distribution head for 2 to 6 hoses available.

APPLICATIONS
BUILDING INDUSTRY

Heating and drying of building locations and all-weather projects.


MARQUEE HEATING

models are especially suited for heating marquees, showrooms


IMAC
and sports halls.
INDUSTRY

Heating of transit sheds, workshops and warehouses.

Full humidity proof switch box with central control


panel, pilot lights and digital temperature
regulation.

Intercal industrial burner with flow control and


lower tray for oil containment.

High pressure radial fan for long distance heat


throw.

Stackable construction with crane hooks.

TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL

PART
NUMBER

GROSS OUTPUT
Btu/hr
kW

IMAC 2000 E 41.729.000 64.1000


IMAC 2000 S 41.729.600 64.1000
IMAC 4000 E 41.740.600 133.0000
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr

kcal/hr

APPROX. FUEL
CONS. OIL
L/hr
KG/hr

185
160.000
18,4
15,3
185
160.000
18,4
15,3
383
333.000
38,0
31,5
1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr

HEATED
AIR FLOW
M3/hr

MAX. BACK
PRESSURE OF
FAN Pa

POWER
CONSUMPTION
400V (AMPS)

OUTLET
CONE
MM

15.000
12.000
24.000

500
500
600-1000

10,4
9,0
20,0

300/500/600
300/500/600
500/600

FLUE
CONNECTION
MM

THERMOSTAT
CONNECTION

YES
200
200
YES
250
YES
SEE PAGE 30-35 FOR ACCESSORIES

11

G models Direct propane gas fired

G 45 E

G 30 E

G 15 E

Working principle MODELS G 15/30/45 E

Adjustable capacity.

Direct heat with 100% efficiency.

Advantages of THERMOBILE G series:

Clean combustion. Easy to maintain. High capacity for low price.


FEATURES
Stainless steel body with synthetic foot.
With
capacity (gas pressure) regulator (G 45 E and
G 30 adjustable
E)
of gas supply.
Security
Thermo
couple
protection.
Room ventilationflame
Service friendly. is required.

12

APPLICATIONS
BUILDING INDUSTRY

Heating and drying of buildings and all-weather projects.


Motor trade , General workshop heating
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL
G 15 E
G 30 E
G 45 E

PART
NUMBER
40.015.000
40.030.000
40.045.000

1 kW= 860 Kcal/hr

Btu/hr
51.250
42.400
89.500

1 kW=3413 Btu/hr

HEAT OUTPUT
MIN.
MAX.
kW kcal/hr
Btu/hr kW
15,0 12.900
51.250 15,0
12,4 10.650 106.600 31,2
26,2 22.500 148.600 43,5
1 kW=3,6 Mj/hr

1 KG/hr=1,2L/hr

kcal/hr
12.900
26.800
37.400

APPROX. FUEL
CONS. GAS KG/hr
MIN.
MAX.
1,17
1,17
0,98
2,46
2,10
3,43

HEATED
AIR FLOW
M3/hr
300
750
850

POWER
CONSUMPTION
230V (AMPS)
0,3
0,45
0,45

GAS
(ON HEATER)
BAR
0,7
1,5
2,0

THERMOSTAT
CONNECTION
-

SEE PAGE 30-35 FOR ACCESSORIES

GA models Direct propane gas fired

GA 110 E
(wheel set standard)

GA 60 E/GA 85 E
(wheel set optional)

GA 42 E

GA 25 E

Working principle MODELS GA 25/42/60/85/110 E


Clean burner because of fresh air connection.
Full humidity and dust proof control panel.

heat with 100% efficiency.


Direct
Adjustable capacity.
Adjustable
outlet temperature between
120 and 180C.

Removable exterior cover for service.


Wheels available as an accessory (GA 60/85).

FEATURES

GA models with burner relay, ionisationflame protection,

thermostat connector and hose breakage protection.

APPLICATIONS
AGRICULTURE

13

of greenhouses and polytunnels


Heating
(N.B. control CO emission).
Heating of stables and sheds.
Drying of agricultural products.
HORTICULTURE

BUILDING INDUSTRY

Heating and drying of buildings and all-weather projects.


portable and mobile models can be connected to
The
gas bottles for on site use. For larger models sufficient
SPECIAL APPLICATION

gas pressure must be available and two or even three


47 kg bottles are required. The heaters may also be
connected to a bulk propane tank.
All GA models can be connected to a modulating
control unit (see page 14/15).
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL

PART
NUMBER

Btu/hr

HEAT OUTPUT
MIN.
MAX.
kW kcal/hr
Btu/hr kW

GA 25 E
43.030.000
51.000 15 12.900
GA 42 E
40.277.000
89.000 26 22.360
GA 60 E*
40.707.005
130.000 38 32.680
GA 85 E*
40.707.002
198.000 58 49.880
GA 110 E
40.710.005
266.000 78 67.000
*) Standard without wheels, for wheel set see accessories.

kcal/hr

APPROX. FUEL
CONS. GAS KG/hr
MIN.
MAX.

85.300 25 21.500
0,9
152.000 44 38.000
1,0
220.000 64 55.000
1,9
320.000 93 80.000
2,8
448.000 130 112.000
3,9
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr

HEATED
AIR FLOW
M3/hr

POWER
CONSUMPTION
230V (AMPS)

1,8
800
0,30
3,1
760
0,52
4,6
2.400
0,64
6,7
2.400
0,64
9,3
4.000
2,20
1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr

GAS PRESSURE
(ON HEATER)
BAR

THERMOSTAT
CONNECTION

0,5-1,5
YES
0,4-1,5
YES
0,4-2,0
YES
0,4-2,0
YES
0,4-2,0
YES
SEE PAGE 30-35 FOR ACCESSORIES

GA EV Direct propane fired, vertical


MS Modulating control units

GA 110 EV

MS 60

GA 60 EV/GA 85 EV

Working principle
MODULATING CONTROL UNITS MS 20, MS 40 AND MS 60
With the MS 60, a drying plant operating to a maximum of 60
kg of propane gas per hour, 20 kg for the MS 20 and 40 kg for
the MS 40, can be controlled in which several heaters (also all
Full humidity and dust
horizontal models) can be connected. The modulating control
proof control panel.
unit ensures that the heat capacity is automatically and constantly adapted to the requirement at any moment. This is a
Clean burner because of fresh
continuous process. The drying of
air connection.
products at highly fluctuating outside temperatures can thus
be improved considerably.
Removable exterior cover for
service.

14

suspension above a fan in a crop drying installation.


For
Blowing upwards is also possible.

The desired temperature is set on the control panel which


measures the temperature of the crop by means of a sensor.
The panel controls the gas pressure regulator with a servo
motor which provides more or less gas flow to the burners
and the temperature is adjusted until the preset value is reached. The measured temperature value is digitally readable.
The servo motor and the gas pressure regulator of this unit can
also be connected to a central storage computer.
The smaller unit MS 20 is supplied as a separate regulator
and a gas pressure regulator to be mounted separately with
a servo motor. On this unit 1 to 3 heaters can be
connected.
Servo motor with gas valve
for connction to central
computer.

Fire protection
system for crop drying.

Full humidity and dust proof control panel containing all


vulnerable components, with fresh air intake connection.

FEATURES

Advantages of MODULATING CONTROL UNITS:

EV models with suspension hooks.


Technical specifications as per GA models. For vertical

MS 20:

Modulating crop drying of smaller amounts of


crop
for an economic price.

MS 60:

modulating control of different sections.


Separate
adjustable crop temperature (to 0,1C).
Accurate
on cost of fuel.
Saving
. Superior product quality.

operation the magnetic valve system is altered to suit.

AGRICULTURE

Drying and storing of agricultural products.


Intense drying of flower bulbs, when a high ventilation standard is required to prevent harmful ethylene emission.

TECHNICAL SPECIFICATIONS

MODEL
GA 42 E*
GA 60 EV*
GA 85 EV*
GA 110 EV*

PART
NUMBER
40.277.000
40.707.005
40.707.002
40.710.005

1 kW= 860 Kcal/hr

Btu/hr
89.000
130.000
198.000
266.000

1 kW=3413 Btu/hr

(dimensions and weights on back page)

HEAT OUTPUT
MIN.
MAX.
kW kcal/hr
Btu/hr kW kcal/hr
26 22.360 152.000 44 38.000
38 32.680 220.000 64 55.000
58 49.880 320.000 93 80.000
78 67.080 448.000 130 112.000
1 kW=3,6 Mj/hr

APPROX. FUEL
CONS. GAS KG/hr
MIN.
MAX.
1,0
3,1
1,9
4,6
2,8
6,7
3,9
9,3

HEATED
AIR FLOW
M3/hr
760
2400
2400
4000

1 KG/hr=1,2L/hr

POWER
CONSUMPTION
230V (AMPS)
0,52
0,64
0,64
2,20

GAS
CONNECTION
INCH
1/2
1/2
1/2
1/2

GAS PRESSURE
(ON HEATER)
BAR
0,4-1,5
0,4-2,0
0,4-2,0
0,4-2,0

SEE PAGE 30-35 FOR ACCESSORIES

ANCILLARIES

Modulating control unit MS 20 (1-20 kg propane), adjusting range 0,4-2,0 bar, connection 1/4" IN-3/8" OUT, supply 230V
Modulating control unit MS 20 (1-40 kg propane), adjusting range 0,4-2,0 bar, connection 1/4" IN-3/8" OUT, supply 230V
Modulating control unit MS 60 (1-60 kg propane), adjusting range 0,4-2,0 bar, connection 1/4" IN-3/8" OUT, supply 230V3-point control with manual operation
Connection accessory for external computer (instead of complete MS):
Modulating control unit MS 60, connection 1/2"
Modulating control unit MS 60,supply 230 VAC 50/60Hz, 3-point control with manual operation
Modulating control unit MS 60,supply 230 VAC 50/60Hz, 3-point control , pot.meter 5K-Ohm for feedback
Modulating control unit MS 60,supply 24 VAC 50/60Hz, control 0-10, Vdc analog
Modulating control unit MS 60,supply 24 VAC 50/60Hz, 3-point control , pot.meter 1K-Ohm for feedback
Modulating control unit MS 60,supply 24 VAC 50/60Hz, 3-point control
Modulating control unit MS 40,adjusting range 0,4-2,0 bar, connection 1/2"
Modulating control unit MS 40,supply 230 VAC 50/60Hz, 3-point control
Modulating control unit MS 40,supply 24 VAC 50/60Hz, 3-point control for feedback
Modulating control unit MS 20, adjusting range 0,4-2,0 bar, connection 1/4" IN-3/8" OUT
Modulating control unit MS 20,supply 230 VAC 50/60Hz, 3-point control
Modulating control unit MS 20,supply 24 VAC 50/60Hz, control 0-10, Vdc analog
Modulating control unit MS 20,supply 24 VAC 50/60Hz, control 0-10, 3-point control
Modulating control unit MS 20,supply 24 VAC 50/60Hz, 3-point control with pot.meter
Temperature probe PT 100 with 10m cable
Temperature probe PTC 100 with 10m cable
Fire protection system for crop drying (propane gas), supply 230 V
Magnetic gas valve for propane gas, 230V, to place in gas supply pipe
Magnetic gas valve for propane gas, 24V, to place in gas supply pipe
Room/Maximum thermostat 0/60 degrees C
Suspension bracket GA 60/85/110 E
Suspension bracket GA 60/85/110 E

THERMOSTAT
CONNECTION
YES
YES
YES
YES

PART NUMBER

40.301.018
40.301.069
40.301.019

40.301.029
40.301.055
40.301.056
40.301.052
40.301.054
40.301.066
40.301.067
40.301.058
40.301.064
40.301.065
40.301.075
40.301.033
40.301.063
40.301.045
40.301.047
40.301.080
40.301.049
40.277.033
40.301.007

15

AGA E Direct natural gas / propane fired

AGA 111 E
AGA 75 E

AGA 45 E

Working principle
Working principle

Easy access for service.

heat with 100% efficiency.


Direct
Fixed outlet temperature circa 60 100C
(adjustable
on modulating model).
Large air throw.

Clean burner because of fresh air connection.


Fan for optimum combustion air.

16

Standard external air suction system


with a wall connector for AGA
45/75/102/111E

Full humidity and dust proof


control panel AGA 45 E/75 E.

Optional: Protection cover for


AGA 45 E and AGA 75 E

Advantages of THERMOBILE AGA series:

Full humidity and dust proof


control panel AGA 100 E/102
E/111 E.

Easy access for cleaning. Clean burner because of fresh air connection.

Good heat distribution.

FEATURES
humidity and dust proof control panel containing all electronic components.
Full
AGA
45 E/75 E/111 E, suitable for propane and natural gas.
With fresh
intake to the burner.
Burner withairelectronic
ignition, ionisation protection and thermostat connection.
Room ventilation is required,
CE-GASTEC-GOST approved.even for models with separate fresh air intake to the burner.
AGA 100 series available in 3 models:
(all models can be used horizontally and vertically, blowing either upwards or downwards)
AGA 100 E: fit for external air suction system.
AGA 102 E: Standard with an external air suction system and modulating burner.
Please note: For AGA models the following pressure at the heater is required:
AGA 100 : minimum 25 millibar, maximum 100 millibar
AGA 102 : minimum 25 millibar, maximum 50 millibar
If the gas supply pressure is higher than the maximum a pressure regulator is required
(accessory).
AGA 45 E/ 75 E/ 111 E:: with external air suction system and wall connector, suitable for propane and natural gas.
Please note: Before ordering please specify gas type.
When using propane gas a pre-pressure regulator is required.

Regulating module 0-10 Volt for connection to external


computer.

Modulating control unit.

APPLICATIONS

SPECIAL APPLICATION: MODULATION

Model AGA 102 E is a natural gas heater which, in


conjuction with a modulating control unit, ensures that
the burner capacity can be continuously altered to the
heat requirement at any moment. With this system the
heating of areas or drying of products at fluctuating
outside ambient temperatures is considerably improved.
Equally important is that with this model the air supply
to the burner is simultaneously automatically adjusted to
the burner capacity.

LIVESTOCK

Heating of pig- and poultry houses.


AGRICULTURE

Drying of agricultural products.


Heating of stables and sheds.
HORTICULTURE

Heating of greenhouses and polytunnels


(N.B. Control CO emission).

17

OPERATING PRINCIPLE MODULATING AGA 102 E


The heater contains a modulating gas valve in addition to a modulating air intake motor which varies the supply to the burner.
A separate modulating control unit, remote from the heater, measures via a temperature probe the room temperature or the product.
If the measured value does not correspond with the pre-set desired value, the modulating control system will be activated. It opens
or closes the motorised gas valve to increase or decrease the heat required automatically. The pre-set and actual temperatures are
digitally indicated. Several heaters can be connected to one modulating control unit, the module requires 0-10 Volt.

TECHNICAL SPECIFICATIONS
MODEL

PART
NUMBER

AGA 45 E
AGA 75 E
AGA 100 E
AGA 102 E

40.745.200
40.775.200
40.720.070
40.722.100

AGA 111 E

40.731.050

Btu/hr
136.000
190.000
-

MIN.
kW
40
56
-

(dimensions and weights on back page)


HEAT OUTPUT
MAX.
kcal/hr
Btu/hr
34.000
48.000**
-

146.000
257.000
360.000
360.000
448.000
360.000

kW
45
75
105
105
130
105

kcal/hr
38.500
64.000
90.000
90.000
112.000
90.000

APPROX. FUEL
CONS. GAS M3/hr
MIN.
MAX.

HEATED
AIR FLOW
M3/hr

POWER
CONSUMPTION
230V (AMPS)

GAS
CONNECTION
INCH

THERMOSTAT
CONNECTION

4,3

4,81 / 3,22
7,81 / 5,42
11,2
11,2

2.500
4.500
7.000
7.000

1,0
1,9
4,8
5,5

1/2
1/2
3/4
3/4

YES
YES
YES
YES

11,21 / 7,52

7.000

5,3

3/4

YES

1 m3/h natural gas, 2 kg/h propane gas.

1 kW= 860 Kcal/hr

1 kW=3413 Btu/hr

1 kW=3,6 Mj/hr

1 KG/hr=1,2L/hr

SEE PAGE 30-35 FOR ACCESSORIES

ANCILLARIES

PART NUMBER

Modulating control unit for AGA 102 E


Regulating module for connecting AGA 102 E to a central computer 0-10V
Pre-pressure regulator
Fire protection system for crop drying (natural gas), supply 230V (24 V execution available optionally), consisting of:
magnetic gas valve for natural gas, to place in gas supply pipe (execution depending on amount of gas and diameter of pipe)
room/maximum thermostat 0/60C, to place in drying installation
Protection cover for gas unit AGA 45 E and AGA 75 E

40.722.018
40.722.019
40.720.063

40.301.049
40.745.098

TAS 800 E Direct oil fired with large air throw

TAS 800 E

Standard with external air suction system

Working principle

High pressure pump for diesel or paraffin.


Fan for optimum combustion air.

heat with 100% efficiency.


Direct
outlet temperature circa 60 100C.
Fixed
Large air throw.
Clean burner because of fresh air connection.

18

Full humidity and dust proof control


panel containing all vulnerable
components.

Fresh air intake connection


prevents pollution of the burner.

Advantages of THERMOBILE TAS 800 E series:

Good heat distribution. Optimum combustion. Easy access for cleaning.


FEATURES

With fresh air intake to the burner.


Durable phosphated body parts with stainless steel casing.
Thermostat connection.
Electric switch components in full humidity and dust proof control panel (IP 54).
With burner relay, photocell flame control and thermostat connection.
High pressure pump with 2-way pipe system for connection to bulk tank (max. length 50 m/height 3 m,
depends on diameter of pipe).
Room ventilation is required.

19

APPLICATIONS
LIVESTOCK

Heating pig and poultry houses.


AGRICULTURE

Drying of agricultural products.


Heating of stables and sheds.
HORTICULTURE

Heating of greenhouses and polytunnels


(N.B. Only use paraffin and control CO2 emission).

TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL

PART
NUMBER

TAS 800 E*
40.467.000
*E = Stainless steel bodywork

MAX. NETT HEAT OUTPUT


Btu/hr
kW
kcal/hr
325.000
95
1 kW= 860 Kcal/hr

81.700
1 kW=3413 Btu/hr

APPROX.
FUEL CONS. OIL
L/hr
KG/hr

HEATED
AIR FLOW
M3/hr

9,5
7,9
7.000
1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr

POWER
CONSUMPTION
230V (AMPS)
4,6

THERMOSTAT
CONNECTION

YES
SEE PAGE 30-35 FOR ACCESSORIES

AT Cabinet used oil fired with flue connection and built-

AT 400 C with C-kit

AT 400/500(C)

AT 500

AT 307

Clean heat.
100%
Fixed
outlet
temperature circa 50 70C.

Fan assisted air


distribution.
Closed combustion
chamber.

Closed combustion
chamber.
Built-in fuel tank.
Separate combustion air intake fan which
can be connected to outside supply.

AT 307

AT 306

AT 306

Clean heat.
100%
Fixed
outlet
circa 50 70C.
Radiation heattemperature
on three sides.

High capacity axial fan


for heat distribution.

20

AT 400

Built-in fuel tank.


Separate combustion air intake fan which
can be connected to outside supply.

Clean heat.
100%
Fixed
outlet
circa 50 70C.
Radiation heattemperature
three sides. on
THERMO:
Fan assisted air
distribution
(Accessory for AT 306).
Perforated combustion chamber (not
suitable near explosive vapours).

Built-in fuel tank.

Built in heat exchanger for high efficiency.


Burner draw system for ease of lighting.
C-version: Radial fan for connection to air
ducting.

To control chimney draught and facilitate drainage of condensate water, a T-piece with draught stabiliser and condensate trap is
an essential basis of the flue stack installation. Available separately or as a part of the standard flue kit (U.K. market).

Advantages of THERMOBILE USED OIL HEATERS:

Saving on fuel expenses.

Odourless combustion. Built-in day tank

FEATURES AT MODELS
and safe housing with powder coating.
Durable
Internal
vapourising
Flame failure securityburner.
High/low manual heatthermostat.
regulation.

ignition system.
Manual
Overheat
thermostat.
Oil overflowsecurity
security
system.

in fuel tank

Built-in overflow protection for burner dish.

APPLICATIONS
AGRICULTURE

Heating workshops.
21

INDUSTRY

Heating and frost protection of halls, transit sheds and warehouses.


AUTOMOTIVE

Heating of garage workshops.


TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL

PART
NIUMBERS

THERMO
AT 306
AT 307
AT 400
AT 500
AT 400 C*
AT 500 C*

41.904.104
41.905.000
41.906.000
41.921.000
41.911.000
41.921.100
41.911.100

*Not available in the U.K

MAX. HEAT RATING


LOW REGULATION
HIGH REGULATION
Btu/hr kW kcal/hr Btu/hr
kW
kcal/hr

66.000
66.000
82.000
125.000
82.000
125.000

19
19
24
36
24
36

16.500 100.000
16.500 100.000
20.500 140.000
31.250 200.000
20.500 140.000
31.250 200.000

1 kW= 860 Kcal/hr

29
29
41
59
41
59

25.000
25.000
35.000
50.000
35.000
50.000

1 kW=3413 Btu/hr

APPROX. FUEL CONS. OIL


L/hr
KG/hr
MIN MAX.
MIN MAX.

HEATED
AIR FLOW
M3/hr

2,0
2,0
2,5
3,8
2,5
3,8

1.000
1.000
3.000
3.000
3.600
3.800

3,0
3,0
4,3
6,2
4,3
6,2

1 kW=3,6 Mj/hr

1,7
1,7
2,1
3,2
2,1
3,2

2,5
2,5
3,6
5,2
3,6
5,2

1 KG/hr=1,2L/hr

TANK
CAPACITY
LITRES

50
50
55
55
55
55

POWER
CONSUMPTION
230V (AMPS)

FLUE
CONNECTION
MM

THERMOSTAT
CONNECTION

0,57
0,23
0,80
1,00
2,00
3,90
4,30

130
130
130
180
130
180

SEE PAGE 30-35 FOR ACCESSORIES

ANCILLARIES

PART NUMBER

T-piece with draught stabiliser from 130 mm to 150 mm (AT 305/306/307/400)


T-piece with draught stabiliser from 180 mm to 200 mm (AT 500)
Extra burner dish AT 305/306/307
Extra burner dish AT 400/500
C-kit* for AT 400/500 (ducting connector and radial fan)

41.900.680
41.910.002
41.900.521
41.910.145
41.910.300

*Not available in the U.K.

BioEnergy Rapeseed oil/ linseed oil fired with flue


connection and built in tank

BioEnergy 1

BioEnergy 2

Advantages of the THERMOBILE BioEnergy series:

Saves on fuel costs. Environmentally friendly. Low emissions of harmful gases.


22

FEATURES
in tank.
Built
BioEnergy
radial fan, Bio Energy 2 has axial fan
Type of fuel:1 has
rapeseed
flax oil.
Bio Energy 2 has a builtoilinorheat
exchanger for high performance.
Odourless burning.
High/low capacity control.
Capacities of 29 and 41 kW.

APPLICATIONS

AGRICULTURE:

Heating workshops, sheds, garages and warehouses.

TECHNICAL SPECIFICATIONS

(dimensions and weights on back page)

CAPACITY
MIN
MAX
kW Kcal/hr
Btu/hr kW Kcal/hr

MODEL

PART
NUMBER

BioEnergy 1
BioEnergy 2
1 kW= 860 Kcal/hr

41.906.150
66.000 19 16.500 100.000 29 25.000
41.921.150
82.000 24 20.500 140.000 41 35.000
1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr

Btu/hr

FUEL
CONSUMPTION KG/H
MIN. MAX.

AIR
DISPLACEMENT
M3/H

FUEL
TANK/LTR

2,0
2,5

1.000
3.000

50
55

3,0
4,3

POWER
CONSUMPTION
AMPERAGE 230V

FLUE
CONNECTION
IN MM

0,80
130
1,00
130
SEE PAGE 30-35 FOR ACCESSORIES

PROHEAT Cabinet oil fired with flue connection and


built-in fuel tank

PROHEAT 40

PROHEAT 60

PROHEAT 80

Advantages of THERMOBILE PROHEAT series:

Low-noise radial fan. Large air volumes guarantee quick heating. Standard equipped with thermostat.
FEATURES

Capacities of 42, 64 and 84 kW net, with an efficiency of 91%.


Plug-and-play principle, quick and easy to install.
Four-sided adjustable outlet opening guarantees equal air distribution and

connection for air duct.


Combustion chamber and heat exchanger of heat resistant steel.
Control panel fitted with switches and warning lights.
Standard equipped with summer/winter circuit for heating or ventilation.

APPLICATIONS
AUTOMOTIVE: Heating of garage workshops.
AGRICULTURE: Heating of workshops.
INDUSTRY: Heating and frost protection of halls, transit sheds and warehouses.

TECHNICAL SPECIFICATIONS

MODEL

PROHEAT 40
PROHEAT 60
PROHEAT 80

PART
NUMBER

(dimensions and weights on back page)

MAX. NETT HEAT OUTPUT


Btu/hr
kW
kcal/hr

APPROX. FUEL
CONS. OIL
L/hr
KG/hr

40.294.000
145.200
42
36.300
4,7
40.296.000
221.600
64
55.400
7,2
40.298.000
290.850
84
72.100
9,5
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr

4,0
6,0
8,0

HEATED
AIR FLOW
M3/hr

CAPACITY
FUEL TANK
LTR

2.800
4.500
5.300

55
75
105

POWER
CONSUMPTION
230V (AMPS)

2,6
6,7
8,0

FLUE
CONNECTION
MM

THERMOSTAT
CONNECTION

120
150
180

BUILT-IN
BUILT-IN
BUILT-IN

23

COOLSPACE Air coolers

COOLSPACE 1

Anti lime and algae tablets

COOLSPACE 2

Advantages of the THERMOBILE Coolspace series:

Outlet panel

cooling is 7 to 10 times more economical than a


Evaporative
conventional system
can cool air temperatures above 30 degrees Celsius
Coolspace
by 14 degrees Celsius or more.
and robust and does not use hazardous freon.
Portable
Spot
cooling
effect, saves money and energy.

24

FEATURES
cooling capacity.
High
low maintenance.
Very
hose connection.
Optional
used as the cooling agent.
Water
Fits through doors.

Outside air is drawn


through the cooling
material which is saturated
internally using tap water
at the same time. The fan
guides warm air through
the cooling material
thereby cooling the air.

APPLICATIONS
cooling garage workshops and warehouses, dry cleaners, marquees.

TECHNICAL SPECIFICATIONS

(dimensions and weights on back page)

MODEL

PARTNUMBER

POWER SUPPLY
VOLT
HERZ

MOTOR AMP
MAX

AIR DISPLACEMENT
M3/H

PUMP
AMP.

FAN
WATT

COOLSPACE 1
COOLSPACE 2

55.016.000
55.036.000

220
220

3,4
6,3

0-3.600
0-16.500

0,85
0,75

250
375

50
50

SPECIAL ACCESSORIES

PARTNUMBER

4 anti lime tablets


4 anti algae tablets
Outlet panel round 900 for Coolspace 2

55.016.001
55.016.002
55.036.020

PRODRY Dehumidifiers

PRODry 35

PRODry 55

PRODry 80

Advantages of THERMOBILE PRODRY series:

Pro Dry 35/55 equipped with condensate collection tank with overflow prevention
and connection for fixed drainage (ProDry 80 standard).
Quick dehumidification of the air.
FEATURES

Compact dehumidifiers with high capacities.


Heavy-duty handle makes transport easier.
Control panel with warning lights for defrosting and full tank.
Fully automatic operation with electronic control of condensation and defrosting

process.
Low-noise compressor and fan.
Simple operation.
Equipped with hour counter (hygrostat optional).

APPLICATIONS

Drying of flooded basements, halls and archives.


Drying of structural works.
To dry damp areas.
TECHNICAL SPECIFICATIONS

MODEL

PRODRY 35
PRODRY 55
PRODRY 80
Hose

PART
NUMBER

CAPACITY
LTR/24 hr
MAX.

50.500.350
30
50.500.550
55
50.500.800
80
00.003.207 a metre

(dimensions and weights on back page)


CAPACITY LTR/24 hr
25C/65% RH 30C/85% RH

OPERATING
RANGE
% RH
C

AIR
FLOW
M3/hr

POWER
CONSUMPTION
230V (AMPS)

TANK
CAPACITY
LTR

17,2
34,5
48,0

35-100
35-100
35-100

350
600
850

3,3
3,5
4,8

6
6
-

26,8
53,0
80,0

2-32
2-32
2-32

25

BX/CH/VTB/PROHEAT 18 Electric heaters

ProHeat 18

CH 18

CH 12

CH 3

BX 15
BX 9
BX 3
VTB 15000
VTB 9000
VTB 3000

Advantages of THERMOBILE ELECTRIC HEATERS

Comfortable heat Suitable for open areas Can be used instantly where power is available
Working principle
26

FAN HEATERS BX:

ELEKTROHEATER ProHeat 18

ELECTRO CANONS VTB/CH

thermostat.
Built-in
Stainless steel elements.
100%
Clean and dry heat.
Fixed outlet
circa 30 60C
(2 steps on BXtemperature
9).
switch for continuous frost
Selector
protection with ventilation or space hea-

thermostat.
Built-in
steel elements.
Stainless
Radial fan for larger heat throw.
100%
Clean and dry heat.
Fixed outlet
temperature circa 40 120C.
Space and spot
heating.
Higher outlet temperature.

thermostat.
Built-in
steel elements.
Stainless
Radial fan for larger heat throw.
100%
and dry heat.
Radial Clean
for extra heat throw (VTB).
Axial fanfan(CH)
Fixed outlet temperature circa 40 100C.
Space and spot heating.
Higher outlet temperature.

ting.

FEATURES
frame suitable for suspension
Combined
as well as carrying .
Stackable

sided outlet opening.


Three
Bodywork
steel.
9 kW and in18stainless
kW capacity.

Hose connection possible.


VTB 3000/9000 with hand grip
CH 3/12/18 with hand grip.
VTB 15000 with wheels.
CH 12/18 with wheels.

Control panel ProHeat 18

Built in 2-step thermostat.

Hose system to reach difficult areas.

ELECTRO HEATERS ARE ESPECIALLY


APPLICABLE IN ROOMS WHERE:

27

APPLICATIONS
AGRICULTURE

oxygen cannot be spared for combustion.


available
no
open
flame
allowed.
clean dry heat isis essential.
low noise level is required.
an odour free environment is necessary.

Heating of livestock areas, dairy parlours, workshops and


packing sheds.

Heating of sorting areas and greenhouses.

Heating of offices, canteens, stores, warehouses etc.

Heating and drying out rooms, often in conjunction with


a dehumidifier.

HORTICULTURE

INDUSTRY

BUILDING INDUSTRY

TECHNICAL SPECIFICATIONS
(dimensions and weights on back page) SEE PAGE 30-35 FOR ACCESSORIES

MODEL

ProHeat 183)
BX 3 1)
BX 9 2)
BX 15 3)
VTB 3000 1)*

PART
NUMBER

40.018.000
40.107.005
40.107.015
40.107.020
40.107.030
VTB 3000 TUK**1) 40.107.032
VTB 9000 2)
40.107.035
VTB 15000 3)
40.107.025
CH 3
40.107.091
CH 12
40.107.092
CH 18
40.107.093

HEAT OUTPUT
Btu/hr
kW kcal/hr

61.500
10.250
30.750
51.000
10.250
9.560
30.750
51.000
10.250
41.000
61.500

18
3
9
15
3
2,8
9
15
3
12
18

15.480
2.580
7.740
12.900
2.580
2.408
7.740
12.900
2.580
10.320
15.480

VOLTAGE

3x400
1x230
3x400
3x400
1x230
1x240
3x400
3x400
1x230
3x400
3x400

HEATED AIR FLOW


MIN. M3/hr
MAX.M3/hr

700
-

1.000
220
900
1.000
225
225
550
1.000
250
600
1.500

1) with 230V cable and plug


2) with 400V cable and 16 Amps plug
3) with 400V cable and 32 Amps plug
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr

ADJUSTMENT
RANGE
kW

0-9-18
0-2-3
0-4,5-9
0-7,5-15
0-3
0-2,8
0-4,5-9
0-6-9-15
0-3
0-6-9-12
0-9-13,5-18

DELTA T
C

120
38
36/28
42
60
55
100
38/60/100
60
100
90

POWER
CONSUMPTION
(AMPS)

13/26,0-400V
8,9/13,2-230V
6,8/13,3-400V
11,1/21,9-400V
13,0-230V
12,0-240V
11,5/13,0-400V
8,0/14,0/23,0-400V
13-230V
18-400V
26-400V

OUTLET
CONE
MM

98
98
120
150
160
300
300

* Not available in the U.K. ** Only available in the U.K.

THERMOSTAT
CONNECTION

BUILT-IN.
BUILT-IN.
BUILT-IN.
BUILT-IN.
BUILT-IN.
BUILT-IN
BUILT-IN.
BUILT-IN.
-

VAL Infra-red radiant oil fired


W
NE

VAL 6-1 STEP/VAL 6-2 STEP

VAL with fuel level indicator.


(except VAL 6 KB).

VAL 6 KB

Vertical inclining with locking mechanism.

VAL MIDI

VAL DAYSTAR

Folding push bar VAL MIDI

Working principle
45 Vertical inclination infra-red heat screen.

28

High pressure burner.

odourless without air flow.


Almost
radiation temperature circa 150C at 70 cm
Fixed
(20C at 3 m).
Spot heating (and limited space heating).

Fuel tank for a minimum of 10 hours


burning duration,
(VAL 6 KB 16 hours burning duration).

Advantages of VAL INFRA-RED HEATERS:

Odourless. Personal (and limited space) heating No air flow.


FEATURES
STEP with a 2 step burner
VAL6-2
Mobile
framework
with rotational heat screen on VAL 6-1 STEP. (DAYSTAR portable)
High pressure burner
Photocell flame control.with 15 sec. prepurge control system and 180 sec. postpurge.
Combustion chamber of fibre ceramic.
Thermostat operation is possible.
230V/50Hz connection.
Room ventilation is required.
VAL 6 KB with oversized tank for 16 burning hours.
Oil preheating set VAL 6 (optional)

29

INFRA-RED HEATERS ARE PARTICULARLY


SUITABLE WHEN:

APPLICATIONS
AGRICULTURE

Spot heating in work areas.


heating in workshops, transit sheds and warehouses.
Spot
Warming up and defrosting machines.
Spot heating in large sheds.

No air flow is desired.

HORTICULTURE

Only a part of a room needs to be heated.

INDUSTRY

BUILDING INDUSTRY

Spot heating on work sites.


personnel heating.
Workshop
Drying and curing in body shops.
MOTOR TRADE

TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)

MODEL

PART
NUMBER

HEAT OUTPUT
MAX.
Btu/hr
kW
kcal/hr

VAL 6-2 STEP


VAL 6-1 STEP
VAL 6 KB
VAL MIDI
VAL DAYSTAR

40.106.000
40.106.200
40.106.100
40.106.050
40.106.030

140.000
140.000
140.000
112.000
52.500

1 kW= 860 Kcal/hr

1 kW=3413 Btu/hr

40
40
40
33
15

1 kW=3,6 Mj/hr

35.000
35.000
35.000
28.000
13.000
1 KG/hr=1,2L/hr

APPROX. FUEL CONS. OIL


L/hr
KG/hr
MAX.
MAX.
3,8
3,8
3,8
2,7
1,7

3,2
3,2
3,2
2,3
1,3

TANK
CAPACITY
LITRES

POWER
CONSUMPTION
230V (AMPS)

40
40
60
38
10

0,25
0,25
0,25
0,25
0,5
SEE PAGE 30-35 FOR ACCESSORIES

THERMOBILE ACCESSORIES
THERMOSTATS

RT 1
RT 2
RT 4

IT 1

DA 1

SPECIFICATIONS
RT1, room thermostat 0/37C with 5 m cable and plug, IP 54
Switching differential 2 degrees.

SUITED FOR
TA, TAS, ITA, ITAS, IMA,
IMAC, GA, AGA

PART NUMBER
40.228.110

RT 2, as RT 1, with 10 m cable, IP 54

TA, TAS, ITA, ITAS, IMA,


IMAC, GA, AGA

40.228.120

RT4, room thermostat -10/+40C with 10 m cable, IP 54


For frost protection from temperatures below 0C.

TA, TAS, ITA, ITAS, IMA,


IMAC, GA, AGA

40.228.100

IT1, duct thermostat 0/100C with 6 m cable and plug.


Switching differential 1,5%. For control of
temperature in ducting system.

TA, TAS, ITA, ITAS, IMA,


IMAC, GA, AGA

40.000.107

DA1, dual connection for thermostat.


For control of 2 heaters on 1 thermostat.

TA, TAS, ITA, ITAS, IMA


IMAC, GA, AGA

41.729.220

Extension cable 10 m for thermostat, with plug.

RT1, RT2, RT4, IT1

40.202.140

SWITCHING / ELECTRONICS

30

Transformer set for electrical connections without 0.


Transformer set for electrical connections without 0.
Soft-starter set for gradual run-in of fan.
Earth leakage switch.
Hour counter.
Timer.
Tank heating set TH 1
Tank heating set TH 2

Wheel set T/TA 16

Set of standard wheels with axle + tow handle + base.


Set of air wheels with axle + heavy duty handle for metal tank.
Set of air wheels with axle parts.
Set of air wheels for synthetic tank
Set of air wheels with axle parts.
Set of air wheels with axle parts + base.
Set of air wheels
Set of air wheels
Set of air wheels
Set of standard wheels with axle + base.
Set of standard wheels with axle + base.
Stacking unit.
Fork truck slots.
Fork truck slots.

IMA 111/185
IMAC 2000 E
IMA 111/185
IMAC 2000 E
IMA 61/111/185
IMA 61/111/185
T/TA 40, ITA 30/45
T/TA 80, ITA 75
TRANSPORT AND STORAGE

Set of air
wheels

T/TA 16
T/TA 16
T/TA 22
T/TA 22
IMA 61/111/185
T/TA 40/80,ITA 40/65
ITA 30
ITA 45
ITA 75
GA 60/85E
GA 110E
G/GA 30
IMA 61
IMA 111/185

41.728.190
41.729.250
41.728.203
41.729.094
41.728.235
41.728.180
40.402 090
40.802.150

Fork truck
slots IMA

40.236.015
40.237.023
40.223.168
40.223.195
41.722.237
40.404.220
41.300.053
40.404.300
40.404.400
40.707.094
40.710.124
40.291.020
41.722.219
41.728.115

THERMOBILE ACCESSORIES
WARM AIR TRANSPORT AND ANCILLARIES

Distribution Head for ITA

For IMA models

DISTRIBUTION HEADS FOR ITA


To be connected to outlet cone of
heater.
Including 1 quick release clamp and 2 hose clips.
DISTRIBUTION HEADS FOR IMA
To be fixed instead of
standard outlet panel (ex works,
if necessary).
Excluding clamps.

DISTRIBUTION HEADS FOR IMAC

CONNECTION PIECES FOR ITA


To be connected to outlet cone of
heater to protect hose from too
high temperatures. Including clamps

For IMAC models

OUTLET OPENINGS
2x300 mm

SUITED FOR
ITA 45/75

PART NUMBER
41.404.153

OUTLET OPENINGS
2x300 mm
2x365 mm
4x300 mm
2x450 mm
4x300 mm
3x365 mm
2x450 mm
2x500 mm
OUTLET OPENINGS
3-6x300 mm
2x500 mm
2x500 mm
4x300 mm
SPECIFICATIONS
Connection piece 300 mm
Connection piece 400 mm, incl.2
quick release clamps
Connection piece . 365
Reducing piece 400- 365 mm

SUITED FOR
IMA 61
IMA 111
IMA 111
IMA 111
IMA 185
IMA 185
IMA 185
IMA 185
SUITED FOR
IMAC 2000 E
IMAC 2000 E
IMAC 2000 S
IMAC 2000 S
SUITED FOR
Hose ITA 30

PART NUMBER
41.722.068
41.724.192
41.724.177
41.724.115
41.728.177
41.728.197
41.728.439
41.728.068
PART NUMBER
41.729.168
41.729.188
41.729.187
41.729.820
PART NUMBER
99.084.041

Hose ITA 45/75


Hose ITA 45/75
Hose ITA 40/65

41.404.152
99.084.023
41.651.128

31

Polyamide with pvccoating, -5/+100C

Glass fibre with neoprene


coating, -20/+140C

Connection pieces for


hose with sleeve

WARM AIR TRANSPORT HOSES


LENGTH IN M
Temperature resistant at -20/+140C.
5
5
5
Temperature resistant at -5/+100C.
5
5
6
6
5
6
6
6

Rubber quick
release clamps

IN MM
150
300
365
100
120
300
365
400
400
500
600

Hose clips, steel quick


release clamps

Y-piece
T-piece

SUITED FOR
VTB 15000
ITA 30, distribution head ITA 45/75
ITA 40/65
VTB 3000
VTB 9000
distribution head IMA 61/111/185, IMAC 2000 E
distribution head IMA 111/185
ITA 45/75
IMA 61
IMA 111, distribution head IMA 185
IMA 185, IMAC 2000 E /2000 S /4000 E

Various reducing and


coupling pieces

PART NUMBER
40.107.071
40.107.077
40.107.078
40.107.270
40.107.275
40.107.276
40.107.278
40.107.079
40.107.280
40.107.282
40.107.284

ATTENTION: Hoses produce BACK PRESSURE which can cause the heater to switch off. Avoid too LONG and/or too NARROW hoses and too many BENDS.
Heaters with RADIAL fans are especially suited.

THERMOBILE ACCESSORIES
CONNECTION PIECES FOR HOSES WITH SLEEVE
To connect hoses. Including hose clips.

SPECIFICATIONS
Connection piece 300 mm
Connection piece 365 mm
Connection piece 400 mm

PART NUMBER
41.218.071
41.728.205
41.404.154

RUBBER QUICK RELEASE CLAMPS FOR HOSES WITH END RING


To connect hoses and if desired to fix to
the heater flange.

FOR HOSE DIAMETER


300 mm
365 mm
400 mm
500 mm
600 mm

PART NUMBER
40.502.067
40.502.068
40.502.069
40.502.071
40.502.073

GALVANISED HOSE CLIPS


To fasten hoses to the heater flange or
to a connection piece.

FOR HOSE DIAMETER


100-102 mm
150-160 mm
50-380 mm
50-540 mm
60-660 mm

PART NUMBER
40.509.158
40.502.251
41.215.073
41.522.195
41.522.196

STEEL QUICK RELEASE CLAMPS


Especially suited to fasten hoses to
ITA models.

FOR HOSE DIAMETER


160 mm
305 mm
365 mm
400 mm

PART NUMBER
41.400.003
41.200.051
41.400.002
41.404.117

DISTRIBUTION PIECES FOR HOSES


Y-piece 1x600 mm / 2x600 mm.
T-piece 45 1x500 mm / 1x500 -1x300 mm.
T-piece 45 1x600 mm / 1x600 -1x300 mm.
Endcover for T-piece 500 mm.
Endcover for T-piece 600 mm.

SUITED FOR HOSES OF


IMA 185/IMAC 2000 E/S
IMA 111
IMA 185/IMAC 2000 E/S
IMA 111
IMA 185/IMAC 2000 E/S

PART NUMBER
41.729.215
41.724.240
41.729.225
41.724.245
41.729.229

RECIRCULATION
32

Recirculation hoses

RECIRCULATION HOSES
With steel spiral to prevent
compression.
RECIRCULATION FLANGES
To be used in combination with
supplied closed panel, to be
fixed instead of standard
suction panel.
Recirculation flange and hose
RECIRCULATIONSET

Recirculation flanges
IMAC 2000 E

LENGTH IN M
10
5
10
FOR HOSE DIAMETER

Recirculationset IMA

IN MM
300
600
600

Recirculation fans, TBE


models

Recirculation fans, TTV


models

SUITED FOR
IMAC 2000 E
IMAC 2000 E/2000 S E/4000 E
IMAC 2000 E/2000 S E/4000 E
SUITED FOR

PART NUMBER
41.729.240
41.729.241
41.729.242
PART NUMBER

3x300 mm

IMAC 2000E

41.729.201

1x600 mm
1x 600mm

IMAC 2000E
IMAC 2000S

41.729.065
41.729.878

IMA 61
IMA 111
IMA 185

41.722.120
41.724.008
41.728.008

400
400
500

THERMOBILE ACCESSORIES
RECIRCULATION FANS
Provide, in combination with heaters, extra ventilation and a better distribution of warm air.
TBE models for HORTICULTURE
Especially suited for serial ventilation, parallel
ventilation and recirculation systems.
FEATURES
Suited for suspension.
Easily stackable.
Shock proof synthetic fan housing.
Double-sided grill according to CE-standard.
Isolation class F, IP 55.
OPTIONS
3-Step control regulator on rear of motor. (50.500.207)
Plug and 4 m cable.
60 Hz motors.
3-Phase motors.

MODEL
TB4E/40Q
TB4E/50Q
TB6E/40Q
TB6E/50Q

POWER
W
230
390
180
300

IN
MM
420
518
420
518

TTV 4500
TTV 7000

230
390

420
518

TTV models on support for (BUILDING) INDUSTRY and RENTAL BUSINESS


Especially developped for use under very severe conditions in
the (building) industry and rental business
FEATURES
Easily portable.
Easily stackable.
Shock proof synthetic fan housing.
Double-sided grill according to CE-standard.
Isolation class F, IP 65.
With cable and plug.
Adjustable support.
Protected 3-step control regulator.
OPTIONS
Hose connection piece to be used on either side.

RPM
1400
1400
900
900

AIR
FLOW
M3/hr
5050
7760
3950
7060

POWER
CONSUMPTION
(AMPS) 230V/50Hz
1,1
1,8
1,1
1,4

AIR THROW
IN M
47
58
36
53

NOISE LEVEL
dB (A)
50
55
47
51

PART NUMBER
50.500.201
50.500.202
50.500.203
50.500.204

1400
1400

4500
7000

1,1
1,8

45
55

60
64

50.500.210
50.500.220

OPTIONS
Hose connection piece 450 mm
Hose connection piece 550 mm
Hose 550 mm, L=7,6 m
Hose 450 mm, L=7,6 m

SUITED FOR
TTV 4500
TTV 7000
TTV 7000
TTV 4500

PART NUMBER
50.500.211
50.500.221
50.500.222
50.500.212
33

SUCTION OF FRESH AIR

Fresh air connection flanges

FRESH AIR CONNECTION


FLANGES FOR SEPARATE BURNERS
Prevents lack of oxygen and
pollution of the burner in dusty areas.
To be mounted on burner.

Fresh air suction hoses

Wall connector

TYPE OF BURNER
Oil burner SLW 22
Oil burner SLW 44/SLW 55

SUCTION DIAMETER
150 mm
150 mm

SUITED FOR
IMA 61
IMA 111/185, IMAC 2000 E

PART NUMBER
99.095.025
99.095.026

SUITED FOR
AGA 45/75/102/111 E,
GA 60/85/110,TAS 800 E
IMA

PART NUMBER

FRESH AIR SUCTION HOSES


For suction of clean fresh air.
To be mounted on connection
flange.

LENGTH IN M

IN MM

5
1

102
150

STAINLESS STEEL WALL


CONNECTOR WITH RAINCAP
Prevents raining in and back pressure.

CONNECTION DIAMETER
100 mm

41.000.585
00.003.283

SUITED FOR
PART NUMBER
Suction hoses GA 60/85/110 E, 40.721.016
AGA 45/75/102/111 E, TAS 800 E

THERMOBILE ACCESSORIES
FUEL SUPPLY

Conversion kit

Oil supply unit

Connection/reduction set

SPECIFICATIONS
Conversion kit from 1-way to 2-way pipe system, for suction from bulk tank, maximum
length 50 m/height 3 m (depends on diameter of pipe).To be mounted on fuel pump.

SUITED FOR
T, TA, ITA

PART NUMBER
41.402.114

Oil supply unit 40 litres to transport oil under pressure from bulk tank to
1 or more heaters, to maximum height of 30 m.

All oil fired models (except VAL )

41.522.211

As above, except for 80 litres capacity.

All oil fired models (except VAL )

41.522.212

Needed per heater: Connection/reduction set with magnetic valve.


Oil filter without connection for return to tank
(only needed when using 2 way pipe system).

All oil fired models (except VAL )

41.522.213
41.522.214

Oil preheating set

VAL-6

44.119.000

SPECIFICATIONS
Oil preheating with cable.
Oil preheating with cable.

SUITED FOR
Burner SLW 22
Burner SLW 44/55

PART NUMBER
41.527.212
41.527.211

Oil filter with water separation and bracket for return pipe.

IMA

41.722.230

Oil filter with water separation, interchangeable with current filter.

TAS 800 E

40.467.052

34

Multitanks

Connection set for gas bottles

SPECIFICATIONS

SUITED FOR

PART NUMBER

Multitank 700 liter


Multitank 1000 liter
Suction set for Multitanks
Raincover for Multitanks

All oil fired models


All oil fired models
Multitanks
Multitanks

99.999.700
99.999.701
99.999.703
99.999.720

Connection set for gas bottles, to increase evaporating capacity.

G, GA

40.700.054

THERMOBILE ACCESSORIES
FLUE STACKS*

Pipes

DESCRIPTION
Galvanised pipes*.

Rain caps

LENGTH IN M
1
1
1

Bushing set for flue

IN MM
150
180
200
300

SUITED FOR
ITA, ProHeat 60
ITA 75, IMA 61, ProHeat 80
IMA 111/185, IMAC 2000 E/S
IMAC 4000 E

PART NUMBER
41.000.562
41.522.172
41.528.192
41.740.665

Galvanised rain caps.*

150
180
200
300

ITA, ProHeat 60
ITA 75, IMA 61, ProHeat 80
IMA 111/185, IMAC 2000 E/S
IMAC 4000 E

41.000.565
41.522.175
41.528.187
41.740.666

Galvanised bends 45*

150
180
200
300

ITA, ProHeat 60
ITA 75, IMA 61, ProHeat 80
IMA 111/185, IMAC 2000 E/S
IMAC 4000 E

41.000.561
41.522.171
41.528.230
41.740.667

Bushing set for flue in polytunnels.

150
180
200
120-130

ITA 40/45/65
ITA 75
IMA 111/185, IMAC 2000 E/S
ProHeat 40

41.652.250
41.750.250
41.528.181
41.000.550

Reducer
* Stainless steel systems available for U.K. market.

SERVICE TESTING EQUIPMENT


35

SPECIFICATIONS
CO2 measuring set
Pressure gauge 0-25 bar 1/8" BSP
Pressure gauge 0-25 bar 1/4" BSP, glycerol filled
Pressure gauge set (with overpressure protection)
Pressure gauge 0-0,6 bar
Soot pump complete with paper and lubricant
Testing paper for soot pump
Filling liquid for CO2 meter
Intertest for oil heaters with SATRONIC burner relays
Testing unit for SATRONIC oil burner relays
Testing unit for SATRONIC gas burner relays
Smokegas thermometer
Chimney gas thermometer, Brigan
Spray can with paint, colour red, content 400 ml
Spray can with paint, colour light grey, content 400 ml
Spray can with paint, colour anthracite, content 400 ml

PART NUMBER
40.000.360
40.000.185
40.000.332 / 40.000.349
40.000.331
40.225.146
40.000.190
40.000.189
40.000.191
40.223.102
40.223.101
40.000.330
40.000.192
40.000.355
60.530.075
60.530.076
60.530.077

HEATER ONLY

DIMENSIONS IN CM
B
C
D

82
119
131
169
82
-

33
46
55
63
33
-

45
73
80
90
30
-

24
31
48
69
18
30
44
75

86
110
108
129
86
108
126
154

33
50
54
67
33
57
39
74

45
60
81
94
45
56
55
101

26
34
62
85
20
42
60
90

50
69
80
27
48
105

125
163
216
120
-

49
62
65
39
-

69
90
98
46
53
71

58
105
131
50
80
120

129
173
186
129
173
186

52
68
69
52
68
69

85
105
117
62
75
90

76
130
158
66
120
135

66
72
82
-

100
100
117
-

151(199)
174(223)
212(271)
300
240
385

71
78
91
81
80
120

128
134
152
136
137
188

190(220)
220(270)
305(500)
600
545
*

202
75
180(240) 80(100)
240(300) 103(104)
300
81
240
80
385
120

142(170)
142(172)
173(172)
136
137
188

220(250)
330(530)
425(625)
600
545
*

49
53
69
55
58
100
100
119
119

18
28
28
28
40
46
46
53
53

27
40
40
50
44
41
41
63
63

40
45
65
13
109
109
119
119

106
110
138
138
138

60
-

40
53
85
85
85

69
81

54
65
54
54
-

35
82
82
82
-

113
25
136
103
127
136
103
-

DIMENSIONS AND WEIGHTS

MODEL

T/TA(S)

T/TA 16
T/TA 22
T/TA 40
T/TA 80
TAS 16
TAS 40
TAS 80
TAS 800 E

82
100
103
124
82
103
122
151

33
36
40
49
33
30
36
58

40
43
63
77
30
39
46
85

ITA 30
ITA 45
ITA 75
ITAS 30
ITAS 45
ITAS 70

120
150
170
120
149
204

39
50
59
39
57
65

IMA 61 A(R)
IMA 111 A(R)
IMA 185 A(R)
IMAC 2000 E
IMAC 2000 S
IMAC 4000 E

145
-

G 15 E
G 30 E
G 45 E
GA 25 E
GA 42 E
GA 60/85 E
GA 60/85 E(V)
GA 110 E
GA 110 E(V)
AGA 45 E
AGA 75 E
AGA 100 E
AGA 102 E
AGA 111 E

ITA(S)

IMA

IMAC
COOLSPACE

G/GA(V)(E)

AT 306
Thermo AT 306
AT 307
AT 400(C)
AT 500(C)
BioEnergy 1
BioEnergy 2
C-kit AT 400/500

INCLUDING PACKING

WEIGHTS
F
KG

19
26
32
13,5
46(46)
46(46)
60(63)
57(61)
-

6
11,5
13
13
16
73(55) 36
55
36
76
55
53
55
-

70
70
85
85
85
-

32
41
51

82
87
98(174)
98(174)
87
98
-

DIMENSIONS IN CM
WEIGHTS
L
B
H
KG

52
60
73
54
70
110
110
129
29

21
30
30
29
40
50
50
67
67

30
42
43
48
44
60
60
94
94

113
113
155
155
155

84
84
75
75
75

60
70
101
101
101

52
67
85
110
110

60
90
15
67
61
90
137(162) 102
172(197) 67
61
90
137
102
109

62
60
62
87
60
62
87
50

131
32
131
122
32
131
122
59

78
17
85
168
211
85
168
27

37
52
70
86
84

7,5
13
21
14
17
41
41
71
71

PROHEAT 40
PROHEAT 60
PROHEAT 80

105
112
122

46
54
68

160
170
189

137
173
197

115
119
132

49
57
71

174
184
202

155
190
210

PRODRY 35
PRODRY 55
PRODRY 80

55
54
65

54
56
73

88
96
115

35
40
61

60
63
65

53
54
70

68
78
67

38
43
65

127
175

30
130

68
160

63
81

115
179

*
*

AGA(E)

36
AT
PROHEAT
PRODRY
BioEnergy

BX
CH
VTB
TB
TTV

COOLSPACE 1
COOLSPACE 2

64
157

65
81

BX 3
BX 9
BX 15

28
35
52

33
45
49

37
37
39

86
37
38
66
55

34
34
52
40
28
37
43

31
31
48
85
39
45
58

40
68
98
55
-

54
-

VAL 6 1/2-STEP 120 62


93
(VAL 6 1/2-STEP packed in 3 boxes)

VAL DAYSTAR
VAL MIDI
VAL 6 KB

VTB 3000
VTB 9000
VTB 15000
PROHEAT 18
CH 3
CH 12
CH 18

VAL

TB4E/40Q
TB4E/50Q
TB6E/40Q
TB6E/50Q
TTV 4500
TTV 7000

MULTITANK 700
MULTITANK 1000

Depending on version

71
91

66
69

81
91

58
-

31
-

52
62
52
62
51
62

52
62
52
62
51
62

32
33
32
33
21
24

114
114

71
71

6
11,5
13

36
40
40

28
36
36

34
49
49

7
13,5
15

95
-

10,5
17,5
33
40
11
23
28

45
72
102
108
38
65
55

36
36
46
57
28
37
42

35
35
51
70
38
45
58

11,5
21
39
53
*
*
*

18
38
53

71
87
42
*
70
96

65
62
42
*
66
67

72
42
32
*
93
93

8
10,5
8
10,5
12,5
15

52
62
52
62
59
69

52
62
52
62
59
69

32
34
32
34
39
40

114
114

71
71

127
164

59
127
165

53

64
86

63
*
43
58
9
11,5
9
11,5
13,5
16,2
64
86

Você também pode gostar