Description: Dry-rot repair and stucco on front left corner (1st and 2nd floor) of SFD including installing new water proofing material on
front porch. ZW1500423
Date Opened: 10/14/2015
Record Status: Final
Record Status Date: 12/21/2015
Job Value: $5,500.00
Requestor:
:
Business Name: HOUSE REPAIR EXTRAORDINAIRE
License #: 911189
Inspection Date
Inspector Name
Inspection Type
Status / Result
Result Comments
10/26/2015
Robert Bernal
Frame
Pass
10/29/2015
11/20/2015
Robert Bernal
Anthony Harbaugh
Anthony Harbaugh
Frame
Final Building
Frame
Pass
Pass
Cancelled
Description: Zoning ok for dry-rot repairs on the first and second stories (front "north east side corner) of an existing SFD. no change in floor
area, foot print, design or density. this is an in-kind, like- for- like repair job only.
Date Opened: 10/14/2015
Record Status: Counter Discussion Only
Record Status Date: 10/14/2015
Job Value:
Requestor:
:
Business Name: House Repair Extraordinaire / Rolf Bell
License #:
Inspection Date
Inspector Name
Inspection Type
Status / Result
Result Comments
Description: Retaining wall failure and west side of garage unstable. Note: Please view from 3400 Calandria side.
Date Opened: 6/9/2015
Record Status: Violation Verified
Record Status Date: 10/22/2015
Job Value: $0.00
Requestor:
https://adhoc1.accela.com/AdHocReportweb/Report/AdapterToReportViewer.aspx?rn=Re... 7/28/2016
Page 2 of 4
:
Business Name:
License #:
Inspection Date
Inspector Name
Inspection Type
Status / Result
10/22/2015
Ed Labayog
Ed Labayog
Ed Labayog
Ivan G Ramirez
1st Inspection
Follow-up Inspection
Monitoring Inspection
1st Inspection
Violation Verified
Cancelled
Scheduled
Cancelled
Result Comments
Inspection Date
Inspector Name
Inspection Type
Status / Result
Result Comments
Inspection Date
Inspector Name
Inspection Type
Status / Result
Result Comments
Description: Residential SFD--Voluntary Non-Engineered Residential Sub- Structural Strengthening: Install holdowns, 3/4" anchor bolts and
5/8" plywood panels.
Date Opened: 3/30/2001
Record Status: Final
Record Status Date: 4/17/2001
Job Value: $9,768.00
Requestor: EARTHQUAKE SAFETY INC
:
Business Name:
License #: 519461
Inspection Date
4/9/2001
4/10/2001
4/11/2001
4/12/2001
4/17/2001
Inspector Name
Inspection Type
Status / Result
Result Comments
INSP CANCELLED
INSP CANCELLED
PARTIAL APPROVAL
APPROVED
APPROVED
INSPECTION CANCELLED
CONTRACTOR CANCELLED WILL RESCHEDULE
NEEDED TREATED WOOD WITHING 6" TO GRADE
BOLTS AND HOLD DOWNS OK
DAVID C MILES
ROUGH 03P
ROUGH 03P
ROUGH 03P
ROUGH 03P
FINAL BUILDING 04P
https://adhoc1.accela.com/AdHocReportweb/Report/AdapterToReportViewer.aspx?rn=Re... 7/28/2016
Page 3 of 4
Inspection Date
Inspector Name
3/27/2001
3/27/2001
Inspection Type
Status / Result
Result Comments
FINAL OK *UTILITY RELEASE 200A SFD
Description: Remodel kitchen - demo to studs and new drywall. No Structural Work
Date Opened: 6/4/1997
Record Status: Final
Record Status Date: 7/18/1997
Job Value: $17,706.00
Requestor: PAUL CARL SCHMIDT GEN'L CNTRCR
:
Business Name:
License #: 199758
Inspection Type
Status / Result
Result Comments
6/19/1997
Inspection Date
Inspector Name
ROUGH 03P
R OK PENDING E & M
6/27/1997
WALLBRD/SHINGLE
03N
FINAL BUILDING 04P
CORRECTION
NOTICE
APPROVED
APPROVED
FINALLED
7/18/1997
Description: Remodel kitchen - Remove and replace electrical fixtures. Chg subpanel to code.
Date Opened: 6/4/1997
Record Status: Final
Record Status Date: 7/18/1997
Job Value: $0.00
Requestor: PAUL CARL SCHMIDT GEN'L CNTRCR
:
Business Name:
License #: 199758
Inspection Date
Inspector Name
6/19/1997
Inspection Type
Status / Result
ROUGH 03P
CORRECTION
NOTICE
ROUGH 03P
APPROVED
FINAL ELECTRICAL 04P APPROVED
6/23/1997
7/18/1997
Result Comments
TWO KITCH CIRCUITS
ROUGH OK PANEL T/C
FINALLED
Inspection Type
Status / Result
Result Comments
6/19/1997
Inspection Date
Inspector Name
ROUGH 03P
2B GA DUCT
6/23/1997
7/18/1997
ROUGH 03P
FINAL MECHANICAL
04P
CORRECTION
NOTICE
APPROVED
APPROVED
https://adhoc1.accela.com/AdHocReportweb/Report/AdapterToReportViewer.aspx?rn=Re... 7/28/2016
Page 4 of 4
License #: 199758
Inspection Date
6/19/1997
7/18/1997
Inspector Name
Inspection Type
Status / Result
Result Comments
ROUGH 03P
FINAL PLUMBING 04P
APPROVED
APPROVED
ROUGH OK
FINALLED
For real-time, direct access to information via the Internet, 24 hours a day - https://aca.accela.com/oakland
https://adhoc1.accela.com/AdHocReportweb/Report/AdapterToReportViewer.aspx?rn=Re... 7/28/2016
Page 1 of 4
Update Results
Description: Dry-rot repair and stucco on front left corner (1st and 2nd floor) of SFD including installing new water proofing material on
front porch. ZW1500423
Date Opened: 10/14/2015
Record Status: Final
Record Status Date: 12/21/2015
Job Value: $5,500.00
Requestor:
:
Business Name: HOUSE REPAIR EXTRAORDINAIRE
License #: 911189
Comment Date
Commenter
Comment
Description: Zoning ok for dry-rot repairs on the first and second stories (front "north east side corner) of an existing SFD. no change in
floor area, foot print, design or density. this is an in-kind, like- for- like repair job only.
Date Opened: 10/14/2015
Record Status: Counter Discussion Only
Record Status Date: 10/14/2015
Job Value:
Requestor:
:
Business Name: House Repair Extraordinaire / Rolf Bell
License #:
Comment Date
Commenter
Comment
Description: Retaining wall failure and west side of garage unstable. Note: Please view from 3400 Calandria side.
Date Opened: 6/9/2015
Record Status: Violation Verified
Record Status Date: 10/22/2015
Job Value: $0.00
Requestor:
:
Business Name:
License #:
Comment Date
Commenter
Comment
https://adhoc1.accela.com/AdHocReportweb/Report/AdapterToReportViewer.aspx?rn=Re... 7/28/2016
Page 2 of 4
6/11/2015 8:49:27
AM
IRAMIREZ
6/12/2015 8:37:56
AM
10/26/2015 1:52:36
PM
2/17/2016 12:20:36
PM
2/18/2016 8:07:57
AM
3/2/2016 1:05:11 PM
IRAMIREZ
ELABAYOG
ELABAYOG
JWANG
ELABAYOG
3/29/2016 1:44:01
PM
ELABAYOG
4/8/2016 11:26:31
AM
ELABAYOG
6/5/15 Spoke with Zola 632-9425 about the follow up inspections on 6/11. Said that Dana, 395-0682, the tenant has
intentions of moving out and that she never received a copy of the NOV. I informed her that if the unit is vacant we can
re-schedule inspections but a new tenant cannot move in until the violation have been addressed. She confirmed the
copy was sent to corporate address. She gave me her email ecreemsapartments@cbhpm.com for which I immediately
sent a copy. 6/11/15 Left a message to Dana Webster. Zola said he suspects she has already moved but did not turn in
her keys. She also said she never received a copy of the NOV I sent previously. She changed the email to
ecreemsapts@cbhpm.com. I double confirmed the address with her. She attempted to send me an email for which she
said 2 attempts failed. I gave her my phone contact info so she could reach me if she doesn't receive it. I sent the NOV
again at the new email and called back after 15 min to confirm she had received it. No Answering machine to leave a
message called a second time same result.
Previous comment an error. Inspection postponed by Marie Taylor. All inspections on Calandria Ave are to be reviewed
by management prior to inspections.
10-22-15 Site inspected, verified that the right side wall of the garage is leaning outward at the base and there is a
crack on the stucco at the corner of the garage door opening. Will review pictures in the office.
Re-visited site on 1-29-16 Sending NOV dated 2-17-16. Re-inspection scheduled for 3-24-16
2-18-16 -Address verified via county assessor website, NOV sent w/ appeal forms and pictures via reg & cert mail, cert
# 7015 1660 0000 0859 6851
3-3-16 Spoke with the property owner Doreen Hazel 510 636-1559 she will start looking for an engineer to evaluate the
garage.
3-24-16 Received the Engineer's report and reviewed with City engineer Shafi Refai, the report states that the
foundation/retaining wall is safe. He recommended repairing the garage wall and installing a trench drain. Notified
owner to request an extension to complete repairs. E. Labayog
4-2-16 Received e-mail from the property owner requesting an extension to do the recommended repairs by the
engineer. Completion is expected by October 1, 2016. I will monitor their plans submittal and permit issuance.
Comment Date
Commenter
Comment
Comment Date
Commenter
Comment
Description: Residential SFD--Voluntary Non-Engineered Residential Sub- Structural Strengthening: Install holdowns, 3/4" anchor bolts
and 5/8" plywood panels.
Date Opened: 3/30/2001
Record Status: Final
Record Status Date: 4/17/2001
Job Value: $9,768.00
Requestor: EARTHQUAKE SAFETY INC
:
Business Name:
License #: 519461
Comment Date
Commenter
Comment
https://adhoc1.accela.com/AdHocReportweb/Report/AdapterToReportViewer.aspx?rn=Re... 7/28/2016
Page 3 of 4
APN: 043A469101801
Unit #:
Comment Date
Commenter
Comment
Description: Remodel kitchen - demo to studs and new drywall. No Structural Work
Date Opened: 6/4/1997
Record Status: Final
Record Status Date: 7/18/1997
Job Value: $17,706.00
Requestor: PAUL CARL SCHMIDT GEN'L CNTRCR
:
Business Name:
License #: 199758
Comment Date
Commenter
Comment
Description: Remodel kitchen - Remove and replace electrical fixtures. Chg subpanel to code.
Date Opened: 6/4/1997
Record Status: Final
Record Status Date: 7/18/1997
Job Value: $0.00
Requestor: PAUL CARL SCHMIDT GEN'L CNTRCR
:
Business Name:
License #: 199758
Comment Date
Commenter
Comment
Comment Date
Commenter
Comment
Comment Date
Commenter
Comment
https://adhoc1.accela.com/AdHocReportweb/Report/AdapterToReportViewer.aspx?rn=Re... 7/28/2016
Page 4 of 4
For real-time, direct access to information via the Internet, 24 hours a day - https://aca.accela.com/oakland
https://adhoc1.accela.com/AdHocReportweb/Report/AdapterToReportViewer.aspx?rn=Re... 7/28/2016