design a residential project which contains of 11 storey apartment type F, 4 storey apartment
type G, 40 houses and 1 mosque. For this project apartment type G is chosen for the design.
The total area for this apartment is 1984m 2 and it consist of 3 block of 4 storey residential
building. The height of the floor to another floor is 3.0 m and roof height is 1.2 m. Total
height of the apartment is 13.2m. The location of the project is in Sungai Buluh, Selangor
Malaysia.
Flexible joint will be used to prevent thermal cracking due to the thermal moving of the
building. Structural material will consists of reinforced concrete. The whole structure design
must suit and fulfils architect design criteria. Basically structure design should satisfy four
concepts:a) Achievement of the designed intended life of the structure.
b) Consideration of accepted theory, experiment and experience and the need to
design for durability. Suitable materials, quality control and good supervision are
important.
c) Ensuring that the quality of the structural materials is adequate in terms of
durability, usage and serviceability.
d) Design, construction and use in service should be considered as a whole. The
realization of design objectives, production, workmanship and maintenance and
use of the structure in service.
2.0
Objectives
3.0
Design Criteria
The main criteria to design the structure based this following Euro code 2:
CODE
DEFINITION
BS EN 1992-1-1:2004 Eurocode 2
BS EN 1992-1-2:2004 Eurocode 2
BS EN 1991-1-1:2002 Eurocode 1
3.1
Structural system:
6570
=252.67 m=260 mm Where minor beams will be = (300 X 200) mm.
26
4100
=157.7 m=160 mm Where minor beams will be = (300X 200) mm.
26
Advantages:
Cheaper than other options.
Structural envelope is shallower than option 1.
Increase the gravity and lateral load resistance.
Disadvantages:
Head room affected.
More formwork is required comparing to option 1.
M&E services are affected and restricted especially at the beams
areas.
Recommended by Engineer: Option 2
4.0
Justification
Criteria
Time
Option 1
Concrete can be cast on-site or pre
Option 2
Concrete can be cast on-site or pre cast,
material delivery
material delivery
L/M/H
Reinforcement will incur more cost
L/M/H
Economical system
L/M/H
L/M/H
L/M/H
L/M/H
Technical
Durability
Cost
Sustainability
Social, Culture
& Politic
disabled user
user
L/M/H
L/M/H
Safety &
Health
L/M/H
L/M/H
5.0
2.0
2.1
2.2
Advantage:
An economical system
Ease of construction with less formwork for beams
Disadvantage:
system
It will cost more and will impose higher deflections for larger spans of beam
2.2.2
Advantage:
Disadvantage:
Required skilled laborers as reinforcement must be placed properly to get the required
3.0 Justification
Criteria
Time
Cost
Sustainability
Option 1
Concrete can be cast on-site or pre
Option 2
Concrete can be cast on-site or pre cast,
material delivery
material delivery
L/M/H
Economical system
L/M/H
Reinforcement will incur more cost
L/M/H
L/M/H
L/M/H
L/M/H
Technical
Durability
loads
L/M/H
L/M/H
Social,
Culture &
Politic
disabled user
user
L/M/H
L/M/H
Safety &
Health
L/M/H
L/M/H