Current Transducer LA 55-P

50 A

For the electronic measurement of currents: DC, AC, pulsed...,


with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).

16019

Electrical data
IPN
IPM
RM

Primary nominal current rms


Primary current, measuring range
Measuring resistance @
with 12 V
with 15 V

ISN
KN
VC
IC
Vd

50
0 .. 70
TA = 70C
TA = 85C
RM min RM max RM min RM max

@ 50 A max
@ 70 A max
@ 50 A max
@ 70 A max

10
10
50
50

100
50
160
90

Secondary nominal current rms


Conversion ratio
Supply voltage ( 5 %)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min

A
A

Accuracy @ IPN , TA = 25C

@ 15 V ( 5 %)
@ 12 .. 15 V ( 5 %)

Linearity error

60 95
60 1) 601)
135 155
135 2) 135 2)

50
mA
1 : 1000
12 .. 15
V
10 (@ 15 V) + IS m A
2.5
kV

0.65
0.90
< 0.15
Typ

IO
IOM
IOT
tra
tr
di/dt
BW

%
%
%
Max
0.2

mA

0.3
0.5
0.6

mA
mA
mA

Offset current @ IP = 0, TA = 25C


Magnetic offset current 3) @ IP = 0 and specified RM
after an overload of 3 x I PN
Temperature variation of IO
0C .. + 70C
- 25C .. + 85C

0.1
0.1

Reaction time @ 10 % of IPN


Response time to 90 % of IPN step
di/dt accurately followed
Frequency bandwidth (- 1 dB)

< 500
<1
> 200
DC .. 200

Closed loop (compensated) current


transducer using the Hall effect

Accuracy - Dynamic performance data


X

Features

ns
s
A/s
kHz

Printed circuit board mounting


Isolated plastic case recognized
according to UL 94-V0.

Advantages

Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.

Applications
AC variable speed drives and servo
motor drives

Static converters for DC motor drives


Battery supplied applications
Uninterruptible Power Supplies
(UPS)

Switched Mode Power Supplies


(SMPS)

Power supplies for welding

General data

applications.

TA
TS
RS

Ambient operating temperature


Ambient storage temperature
Secondary coil resistance @

Mass
Standards

Notes:

1)
2)
3)

TA = 70C
TA = 85C

- 25 .. + 85
- 40 .. + 90
80
85
18
EN 50178: 1997

C
C

Application Domain
Industrial.

Measuring range limited to 60 A max


Measuring range limited to 55 A max
Result of the coercive field of the magnetic circuit.
page 1/2

080114/13

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.

w w w .lem.com

Dimensions LA 55-P

(in mm. 1 mm = 0.0394 inch)

Front view

Bottom view

Left view

Connection

Mechanical characteristics
General tolerance
Primary through-hole
Fastening & connection of secondary
Recommended PCB hole

Safety
0.2 mm
12.7 x 7 mm
3 pins
0.63 x 0.56mm
0.9 mm

This transducer must be used in electric/electronic


equipment with respect to applicable standards and
safety requirements in accordance with the
manufacturer's operating instructions.

Remarks
IS is positive when IP flows in the direction of the arrow.
Temperature of the primary conductor should not exceed
90C.
Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.

Caution, risk of electrical shock


When operating the transducer, certain parts of the module
can carry hazardous voltage (eg. primary busbar, power
supply).
Ignoring this warning can lead to injury and/or cause
serious damage.
This transducer is a built-in device, whose conducting
parts must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.

page 2/2

080114/13

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.