Escolar Documentos
Profissional Documentos
Cultura Documentos
Disclaimer
THIS PRESENTATION IS PROTECTED BY U.S. AND INTERNATIONAL COPYRIGHT LAWS.
REPRODUCTION, DISTRIBUTION, DISPLAY AND USE OF THE PRESENTATION WITHOUT WRITTEN
PERMISSION OF THE SPEAKER IS PROHIBITED.
THE INFORMATION IN THIS DOCUMENT IS BELIEVED TO ACCURATELY DESCRIBE THE
TECHNOLOGIES ADDRESSED HEREIN AND IS MEANT TO CLARIFY AND ILLUSTRATE TYPICAL
SITUATIONS, WHICH MUST BE APPROPRIATELY ADAPTED TO INDIVIDUAL CIRCUMSTANCES.
THESE MATERIALS WERE PREPARED TO BE USED IN CONJUNCTION WITH A FREE EDUCATIONAL
PROGRAM AND ARE NOT INTENDED TO PROVIDE LEGAL ADVICE OR ESTABLISH LEGAL
STANDARDS OF REASONABLE BEHAVIOR. NEITHER PACIFIC GAS & ELECTRIC (PG&E), SOUTHERN
CALIFORNIA EDISON (SCE) NOR ANY OF ITS EMPLOYEES AND AGENTS:
(1) MAKES ANY WRITTEN OR ORAL WARRANTY, EXPRESSED OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE;
(2) ASSUMES ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS
OF ANY INFORMATION, APPARATUS, PRODUCT, PROCESS, METHOD, OR POLICY CONTAINED
HEREIN; OR
(3) REPRESENTS THAT ITS USE WOULD NOT INFRINGE ANY PRIVATELY OWNED RIGHTS,
INCLUDING BUT NOT LIMITED TO PATENTS, TRADEMARKS OR COPYRIGHTS. FURTHERMORE,
THE INFORMATION, STATEMENTS, REPRESENTATIONS, GRAPHS AND DATA PRESENTED IN
THIS REPORT ARE PROVIDED BY PG&E AND SCE AS A SERVICE TO OUR CUSTOMERS. PG&E
AND SCE DO NOT ENDORSE PRODUCTS OR MANUFACTURERS. MENTION OF ANY PARTICULAR
PRODUCT OR MANUFACTURER IN THIS COURSE MATERIAL SHOULD NOT BE CONSTRUED AS
AN IMPLIED ENDORSEMENT.
INTRODUCTION
INTRODUCTION
US Department of Energy
INTRODUCTION
FOUNDING ORGANIZATIONS
UTILITIES
MANUFACTURERS
LARGE END-USERS
Course Topics
Part 1: Technology Overview
Common lighting terminology
Residential lighting technologies
Part 2: Background and Policy
Why Title 24?
Savings opportunities
Benefits and results
Part 3: Technology & the Code
Lamps, luminaires and controls
Part 4: Lighting Design Guide
Title 24 residential lighting regulation
Design examples to reach or exceed code
Part 5: Compliance Process
Step-by-step: the Title 24 compliance process
corporate.honda.com/smarthome/
INTRODUCTION
Learning Objectives
1. Effectively apply the residential Title 24 Building Energy Efficiency Standards
requirements specific to lighting.
2. Apply Title 24 Building Energy Efficiency Standards compliance methodology
and procedures in professional practice.
3. Identify current lighting technologies, including LED luminaires, that are
available to fulfill code requirements.
4. Prepare for the major lighting-related updates in the 2013 Title 24 Building
Energy Efficiency Standards code.
5. Access resources through utility and lighting technology training centers for
continued professional development.
INTRODUCTION
INTRODUCTION
EnergyCodeAce.com
INTRODUCTION
2.
3.
Luminous Flux
Lux
Footcandle
Illuminance
Efficiency
Efficacy
CCT
CRI
TECHNOLOGY OVERVIEW
Terminology
Luminous flux: rate of flow of
visible light emitted from a light source
over time, measured in lumens (lm).
TECHNOLOGY OVERVIEW
Terminology
TECHNOLOGY OVERVIEW
Terminology
Efficiency: the ratio between the useful output
of energy and the input of energy.
Luminous Efficacy compares the amount of light
produced by a lamp (lumens), to amount of power
consumed to produce it (watts).
TECHNOLOGY OVERVIEW
Terminology
Luminous Intensity: the concentration of light emitted from a given source in a
particular direction, measured in candela (cd) (1 cd = 1 lm per steradian).
TECHNOLOGY OVERVIEW
Space
Illuminance
Public spaces
B (5fc)
C (10fc)
D (30fc)
E (50fc)
F (100fc)
Terminology
Correlated Color Temperature (CCT)
A specification of the color appearance
of light emitted by a lamp, relating its
color to the color of light from a source
when heated to a particular temperature.
TECHNOLOGY OVERVIEW
TECHNOLOGY OVERVIEW
CCT
TECHNOLOGY OVERVIEW
CRI
Photo: Soraa
TECHNOLOGY OVERVIEW
CRI
Color Rendering Index (CRI)
Color rendering is defined as Effect
of an illuminant on the color
appearance of objects by conscious
or subconscious comparison
with their color appearance under a
reference illuminant
(CIE 17.41987)
It is the only color rendering metric
with wide spread acceptance
It is calculated by comparing the
color appearance of the test source
to a reference source for 8 reflective
samples (Score from 1100)
All other aspects of the source for a
true comparison should be the same
Photo: Soraa
TECHNOLOGY OVERVIEW
CRI
8 SAMPLES USED IN CALCULATION
6 ADDITIONAL SAMPLES
TECHNOLOGY OVERVIEW
Work Shopping
TECHNOLOGY OVERVIEW
TECHNOLOGY OVERVIEW
12,000
10,000
8,000
6,000
4,000
2,000
California
United States
2008
2006
2004
2002
2000
1998
1996
1994
1992
1990
1988
1986
1984
1982
1980
1978
1976
1974
1972
1970
1968
1966
1964
1962
1960
Note: This guide is not intended to be used in lieu of the Title 24 Building Energy Efficiency Standards.
Please visit www.energy.ca.gov/title24 to download the official Title 24 Building Energy Efficiency Standards
as well as the Nonresidential Compliance Manual. To obtain a printed copy of the standards, contact the
California Energy Commissions publications unit: (916) 654-5200.
Lighting in Title 24
Lighting is the largest electrical load
in both homes and businesses,
accounting for
35%
of commercial annual electricity use and
22%
of residential annual use.1
Performance Standards
Allows the builder more freedom,
but the standards are more complex
and involved
Detailed accounting of energy trade-offs
between measures is possible
Uses Energy Commission-approved
computer software to calculate energy
trade-offs based on Title 24 guidelines
Sources
Controls
Sensors
Occupancy/vacancy sensors and daylight
sensors are all devices that automatically turn
lights off (or dim them) in response to conditions
that they sense or see.
Dimmers
Dimmers, which are already common in many
residential applications, allow room occupants
to lower lighting levels (and thus energy use)
as desired.
TECHNOLOGY & THE CODE
5W or less
30 lm/W
5W 15W
40 lm/W
15W 40W
50 lm/W
Over 40W
60 lm/W
Lamp Power
5W or less
30 lm/W
5W 15W
40 lm/W
15W 40W
50 lm/W
Over 40W
60 lm/W
5W or less
30 lm/W
5W 15W
45 lm/W
15W 40W
60 lm/W
Over 40W
90 lm/W
In the 2013 code: Table 150.0-A and 150.0-B and Section 150(k) 1
No Permanent Adaptors
If a luminaire has a screw-base socket, or an adaptor with a screw-base socket, it
is NOT high efficacy, regardless of manufacturer claims.
High-Efficacy Luminaires
Typically Compliant
High-efficacy fixtures with
electronic ballasts
Photo: Permlight
Not Compliant
Any fixture with incandescent
replacement lamps
Appendix JA8-1
Requirements include:
Indoor:
CRI 90 or above
CCT: 2700K 4000K
Outdoor:
CCT: 2700K 5000K
Exception:
Monochromatic LEDs that are only
for decorative purposes
Quality control:
Each integral LED luminaire or
LED light engine tested shall
produce the same quantity and quality of light.
http://www.appliances.energy.ca.gov/AdvancedSearch.aspx
Electronic ballasts
Certified to the Energy
Commission
Mandated in all high-efficacy
luminaires of 13W or higher
Output frequency of no less than
20 kHz
IC applications:
Ballasts that are rated for higher
operating ranges
Photo: Cree
Recessed Luminaires
Have a minimum rated life of
30,000 hours when operated at or
below a specified maximum case
temperature
Must not exceed maximum ballast
case temperature
Have a ballast factor of not less
than 0.90 for non-dimming ballasts
Have a ballast factor of not less
than 0.85 for dimming ballasts
Allow ballast maintenance and
replacement from below the ceiling
without cutting holes in ceiling
Airtight Label: ASTM E283
The ASTM E283 label certifies a
fixture as being airtight in accordance
with ASTM E283 testing and Title 24.
In the 2008 code: 119 (n) and 150 (k)12
In the 2013 code: 110.9 (f) and 150 (k)8
Photo: Lutron
Dimmer Requirements
Dimmer Requirements
Photo: Lutron
Dimmer Requirements
Comply with Title 20
Very subtle differences in language
The dimmer shall:
Photo: Lutron
Dimmer Specifications
Specify the correct load amount
Line voltage
Low voltage
Photo: Lutron
High efficacy or
Manual-on vacancy sensor
High efficacy or
Manual-on vacancy sensor or
Dimmer
Outdoor Lighting
High efficacy or
Low efficacy controlled by a manual on/off switch and both:
Motion sensor without bypass switch and
One of the following: integral photocontrol, astronomical time
clock, energy management control system
Common Areas
Residential Parking
Bathroom
High efficacy or
Manual-on vacancy sensor or
Dimmer
Outdoor Lighting
High efficacy or
Low efficacy controlled by a manual on/off switch and both:
Motion sensor without bypass switch and
One of the following: integral photocontrol, astronomical time
clock, energy management control system
Common Areas
Residential Parking
Lighting Controls
High-efficacy and low-efficacy light
fixtures must be controlled
separately
Nook lighting must be on a
separate switch in order to be
counted as an other space and
not part of the kitchen
Recommended to separately
switch different layers of the
kitchen lighting
Special Circumstances
Appliances
Lighting that is part of an appliance is
not regulated by the code
Blank Electrical Boxes
Calculated and treated as 180 watts of
low-efficacy lighting
Internal Cabinet Lighting
Not considered part of the kitchen
lighting for calculating 50%
No more than 20W per linear foot
of illuminated cabinet
Photo: CLTC, UC Davis
Photo: Lutron
Bathroom Requirements
Lighting
At least one luminaire has to be
high efficacy.
Controls
Low efficacy controlled with a
vacancy sensor
High-efficacy and low-efficacy light
fixtures must be controlled
separately.
Quantity
The quantity of light fixtures is not
regulated by the code.
In the 2013 code: see 150(k) 5
Vacancy Sensor
Vacancy sensors must be manual
on/off and automatic off
Sensors cannot have an override
allowing the light fixture to be
continuously on
The maximum time delay to turn
off is 30 minutes after the last
detected motion
Bedrooms
High efficacy, vacancy sensor, or dimmer
High-efficacy and low-efficacy light fixtures must be controlled separately
Vacancy sensors must be manual on/off and automatic off
Switched outlets (half-hots) do not require special controls
Ceiling fans with incandescent light kits need one switch for the fan and one
dimmer/vacancy sensor for the lights.
High-efficacy: only one switch is needed, two are shown for flexibility
Photo: Maxlite
Photo: Hunter
Hallways
High efficacy, vacancy sensor or dimmer
Vacancy sensors must view the entire space (this application may require
three-way switching as shown)
Override Switch
Low-efficacy outdoor luminaires may have a
temporary override switch which bypasses
the motion sensing function for up to six
hours, provided that the override switch
automatically reactivates the motion sensor.
LEDs lifespan is significantly longer than other lamp sources, requiring less
maintenance.
Although not required by the standards when using a high-efficacy fixture,
including a motion sensor will provide light to occupants upon entering the
space when no immediate access to a switch is available.
For outdoor areas close to bedroom windows, high-efficacy luminaires are
preferred over low-efficacy luminaires with motion sensors that may be
triggered in the middle of the night.
Although not required by the standards when using a high-efficacy fixture, including a
motion sensor (as shown) will provide light to occupants where there is not immediate
access to a switch in a transitional space.
Motion sensor coverage should not be too large, or lights will be triggered by street traffic
or a neighbors motion. Most sensors have a sensitivity control to adjust the degree of
motion and light that triggers them.
In addition to the motion sensor and one of the three other lighting control options, the
owner also must be provided with a manual on/off switch for low-efficacy luminaires.
Low-rise
Multi-family
Common Areas
A multi-family complex consists of four
or more dwelling units. A low-rise is
considered a building with three or
fewer stories.
If the building has more than three
stories the common areas must comply
with the non-residential code.
Low-rise
Multi-family
Common Areas
In buildings where common areas
constitute > 20% of the floor space:
Permit Application
Design teams must make sure that the plans contain all the information that the building official will need to
verify that the building or system satisfies the requirements.
Plan Check
The plans examiner of the local building department must verify that the building or system satisfies the
requirements of the standards and that the plans (not just the compliance forms) contain the information to
be verified during field inspection.
Construction
Contractors must carefully follow the approved plans and specifications, and the building department field
inspector(s) must verify that the building or system is constructed according to the plans and specifications.
Acceptance Commissioning
After completion of construction, the contractor and/or the design team must properly commission the
building and its systems and provide information and/or training to the building operators on maintenance and
operation of the building and its equipment.
Operation
After occupancy, the building and its systems must be correctly operated and properly maintained.
COMPLIANCE PROCESS
Mandatory Measures
Mandatory measures required
by both prescriptive and
performance approaches include
the following areas:
Building envelope
Space conditioning, water heating
and plumbing
Ducts and fans
Pools and spas
Fireplaces
Lighting
COMPLIANCE PROCESS
COMPLIANCE PROCESS
Outdoor Lighting
Controls (Switching)
What the BI
Is Looking For
Cabinet lighting
Recessed luminaires
CLTC Website
cltc.ucdavis.edu