Você está na página 1de 29

1005,

Block B, Level 10, Phileo Damansara 1,


No. 9 Jalan 16/11, Off Jalan Damansara, 46350 Petaling Jaya.

Client : Chong Hwa Independent School


Date : May 2016
Presenter :

Kok Soon

Green Earth
Concept
Sdn Bhd

Renosun (KL)
Sdn Bhd
Incorporated
in 2010

(1075655-U)

Renosun Sdn Bhd (921737-W)


Installation
over 300
sites

Principal
Business

Electricity Generation Sources in MY


Minerals

Natural

Our Offerings
Energy
Assessment

Energy Solutions

Solar
PV
Energy
Review

Post Installation
& Commissioning

Building

Solar

Thermal
Renewable
Energy

Automation

Energy

Monitoring

System

LED
Energy

Energy

Monitoring

Chiller

Cleaning

Service

Savings

Device

Usage

Benchmark
Monitoring

System

Solar PV Components
Data
Logger

Solar
Panel
Smart
Meter

Inverter
& DB
Box
TNB
Outgoing
Meter

Batteries
for Off
Grid

Solar Photovoltaic (PV) Schemes


Off Grid

On Grid
FiT Program
(Sell to TNB)
+ Residential
+ Land
+ Shoplots/
Factory

Own

Negotiated
(Sell to TNB)

Solar Farm

Consumption
+ Commercial/

Schemes

Factory

Standalone

1 kW = 3.6 ~ 3.7 h
= 3.7kWh/day
72kW = 3.7 h x 365days
x 72kW
= 97,236kWh/yr
Or 266 kWh/day

Good
day
6.6kWh

Raining
day
2.54kWh
Cloudy
day
5.03kWh


Own Cash

Bank Loan (up to 75%)

Investment

RM541,900

RM541,900

Cash Outlay Upfront

RM541,900

RM135,468

20% per annum

32% per annum

6 Years

1st Year

From RM53,302

RM53,302

Total Incentives (1st Year)

RM181,527

RM204,387

Total Incentives (6 years)

RM270,936

RM293,796

Return On Investment
Payback period
Electricity Savings Per
Annum

Notes:Bank loans available.


System can last beyond
25 years.
If Bank Loan is taken, first
year will recoup cash
outlay

Warranties:
Solar PV Modules 12
years product defect
Solar PV Modules 25
years performance
efficiency not < 80%

Warranties:
Inverter 7 years
Installation 1 year

SEDA Annoucement on Community Quota

Location Feasibility & Capacity


Facts:1. Red outline roof alone can fit 190 kW Solar PV
System.
2. Sun Direction is reasonable with no possible
shading.
3. Roof direction is East & West.

Possible Options:1. Install 48 kW system via Community Quota


under Feed-in-Tariff Scheme to Earn Superior
Return on Investment ie sale of electricity to
TNB.
2. Remaining capacity can be invested to generate
for own consumption (Caution: if there is no
afternoon school session, then we may only
consider office usage of electricity or areas
where electricity is used in the afternoon.
3. Due to availability of school holidays, installing
for own consumption is generally not advisable.

Latest Projects

When You Feel The Sun


Think Of Renosun

Solar Farm 1Borneo Shopping Complex Car


Park (Additional Income Source)

Recent Projects Roof Material

Car Porch/Test Field/Factory Roof

Off Grid System Arguably Largest Privately


Owned in Msia

WHY INVEST IN A SOLAR PV


ELECTRICITY GENERATION
SYSTEM???
Independent Source
Help Minimise Tax
Payments
Countering Inflation
Alternative Investments
Low Maintenance
Improving Underprivileged
Lifestyle
No Carbon Emission
Strong ROI & Payback
Period

WHY RENOSUN
???
When You Feel The Sun
Think Of Renosun

1. Financial Capability & Accuracy of Diagnosis


Own Consumption

ROI from FIT Scheme


1,400,000.00

Own Consumption Electricity Savings

1,200,000.00

Net Cash Flows


3,000,000

800,000.00

2,500,000

600,000.00
400,000.00
200,000.00
(200,000.00)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

(400,000.00)

Amount (MYR)

AMOUNT (MYR)

1,000,000.00

Cash Inflows From CA and ITA Effect

2,000,000
1,500,000
1,000,000
500,000
-

YEAR

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Year

Eletricity Cost
Stream of incomes after paying off electricity bill

Accumulated Net Cash Flow (FIT


Scheme vs Own Consumption)

Renewable Energy Fund Contributions 1.6% + Tax Pmts

1. FIT Rate is constant over 21 years but


inflationary effects on electricity cost as well
as the run off of CA & ITA Effects from 17th
year onwards will create a negative cash flow
situation
2. ROI for FIT is ranging from 12% - 17% per
annum whilst ROI for Own Consumption is
ranging from 22% to 45%.

ACCUMULATED AMOUNT (MYR)

Net CF Streams From FIT Scheme

25,000,000
20,000,000
15,000,000
10,000,000
5,000,000
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
YEAR
Accumulated Net Cash Flows (FIT Scheme)
Accumulated Net Cash Flows (Own Consumption)

2. Strategic Tie-Ups In Other Areas of Expertise

3. In-Depth Power Usage Diagnosis & Analysis


Comparison

Before implementation

After implementation, reverse of


Sun Irradiance curve

4. Technology Driven In Many Aspects of Our Work

5. Detailed Requirement Specifications


Probable Usage - Solar Grid-Tie / Power
Backup (24hrs daily usage with 1day
backup)
McValue 1 : Ground Floor Lightings
(Excluding Kitchen Lightings)

Power requirement *

Estimated power requirement for Watta Qua Total


specific area/equipment
ge
ntity (W)
(w)
at one
mome
nt
Ground Floor LED Lightings
L1 (LED 2 X 7W)
L2 (LED 2X 9W)
L2-S (16W)
L4 (LED 9W)
L5 (26W CFL or LED 1100 Lumen)

14
18
16
9
26

4
9
3
31
28

Total

83

75

56
162
48
279
728
0
1273

Grand Total

83

75

1273

Estimat Total
e daily Wh
usage (day)
(hours)*
*
24
24
24
24
24

1344
3888
1152
6696
17472
0
30552 Wh

30.552 kWh

Ground
Floor
Inverter Sizing
From the total wattage, the Inverter size must be able to accommodate maximum wattage at
one go.
Instantaneous power
1273
W
Factoring energy loss (1 to 1.5)
1.5
Minimum Inverter size
1.91
kW
Battery Sizing
Total daily power required
Factoring Efficiency loss of the system [1 to 1.5]
Power required daily

30552
1.5
45.828

Wh

Battery Bank Capacity (AH),


total kWh usage per day (power required)
Number of storage days needed
Depth of Discharge [50% = 2]

45.83
1
2

kWh
days

Power required for 2 days

91.66

kWh

Battery system volltage


Total battery capacity needed..

48
1910

Battery Configuration
Using Trojan Deep Cycle Flooded Lead Acid Batt.

AH
1110

kWh

V
AH
Voltage
2

Batteries setup to the equivalent battery system voltage (for a series


connection)
Number of batteries in series connection
24
Number of parallel connections needed (not more than 2)
2
Total battery capacity (equivalent or nearest to batt. cap)
2220
AH
Total numbers of batteries needed each system

48

batteries

Total batteries for whole system

48

batteries

6. Ability to Plan System Connectivity

7. Engineering Capability
300.00

340.00

7.5 kW
Kaco
Inverter

12kW Kaco
Inverter

810.00

690.00

420.00

Note: Every inverter require


a space of 30cm
surrounding it.

DB for
Inverter

DB for
Inverter
300.00

400.00

300.33
360.00

360.00

Piccolog

107.00

152.00

400.00

Spacing dimension for solar PV inverters and DBs

8. Government Regulation & Incentives

These Capabilities Won Us McDs Deal

Some of Our Key Clients


FIT Programme: Residential House Owners
Shoplots Owners
Churches.Schools
Factories Rooftops
1Borneo Shopping Complex
Own Consumption: McDonalds - Putrajaya
Big Tree Farm & Restaurant
Eko Metal Industries Sdn Bhd
Organic Farm @ Pahang Hill
Institute Technology Kedah
Residential Houses
Solar PV Test Fields: Hanwha Q-Cells SB
Energy Savings: OCBC Bank (M) Bhd

Deals-In-Progress
Own Consumption: Sabah Development Corp SB
Dynamic Mould SB
Latitude Tree Furniture SB
Beckers Industrial Coating Bhd
Bangsar Village Shopping Complex
Niro Granite Bhd
Bukit Ramai Holdings SB
Penang Skill Development Corporation
Sutramas Condominium
Shell Petrol Station Kota Kinabalu
McDonalds Y2017 15 outlets
Utility Scale Solar Farms : Kwantas-Nefin Consortium 36 Megawatt
Suria Technology-Renosun-Phoenix Solar
Consortium 7 Megawatt
Evacuated Vacumm Tubes Hot Water & Energy
Savings: Sungai Buloh Hospital
Gleneagles Hospital Kota Kinabalu

TouchPoints
www.renosun.my

Renosun KL Sdn Bhd

Assistance Appreciated
Ideal Customers:-

Ideal Investors, Networking Partners or


Business Partners

Export
based
Manufacturing
Companies
Owner Operated Factories
Golf Clubs
Owners of Standalone Buildings
such as Petrol Stations / Car
Showrooms / Restaurants (KFC)
Owners of Vacant Land

Private Equity Fund Managers


High Networth Individuals Solar
Farm Investment
Architects/M&E Consultants

Characteristics: Electricity per month >


RM30k
Operate at least 6 days a
week
Power usage is consistently
high over sunlight hours
Making Profits