Scope
The scope of this document is to give a detail procedure for the commissioning of the
Huawei DBS3900 base station. The document will provide the required tools, contacts
and procedures to be followed.
Document Revision
Version
Author
Draft
V1.0
V1.1
V1.2
S Perkins
Pan Fei
Pan Fei
Pan Fei
Reviewer
Date
Approver
02/11/2009
04/20/2009
04/27/2009
05/15/2009
Change Log
Initial Draft
V1.0
V1.1
V1.2
1. Tools List
Tools
Compass
Digital Camera
GPS Navigation (Optional)
Laptop
Mobile Phone (For
communication)
Test Data Card
Test Mobile Phone and SIM
USB Flash Memory Stick
UTP Network Cable
Vehicle
Multi meter
Sub Contractor
Huawei
X
X
X
X
X
X
X
X
X
X
X
2. Site Awareness
There are a number of site in Canada that are in remote location that require
situational awareness therefore when travelling to and from remote site locations it is
important that the engineer is equipped for travel to remote sites
Engineers must also be aware that Tower work takes precedent over any other site
work; therefore if tower work is in progress then the tower crew is in control of the site.
2009-05-15
HUAWEI Confidential
Page2, Total30
Security Level:
If required the engineer may have to remain off site until tower crews have finished
any ongoing operations. If tower work is in progress then hard hats are required to be
worn onsite.
3. Commissioning Process
The commissioning process for the Huawei DBS3900 will follow the flow shown below.
The following section will provide a breakdown of the activities required for successful
commissioning of the base station.
2009-05-15
HUAWEI Confidential
Page3, Total30
Security Level:
4. NTP Report
The NTP report is a report that details which sites have received Notice to Proceed
(NTP) from the customer. This report then provides the basis for scheduling activities
for commissioning preparation and commissioning activities. From this report a
forecasting schedule will then be produced to initiate the site configuration data to be
prepared and the scheduling of engineers to attend site for commissioning.
The details of this process are not covered in this document and is only included for
informational purposes.
5. Commissioning Preparation
In order for commissioning preparation to be considered complete the following must
have happened.
1. Confirmed NTP report released, hardware installation completed, NodeB was
powered on and IP connectivity is available (Telus)
2. Iub data and cell data for the NodeB is downloaded to RNC (Huawei)
3. Cells were correctly declared on Core Network side (NSN)
4. NodeB was created on OSS (Huawei)
5. IPCLK links were created on 2 IPCLK servers
6. Sub-contractor team got the correct NodeB software and Script from Huawei.
7. Sub-contractor team got the special USB memory stick with LED available and
kept the NodeB software and script with the correct name, file format in the
correct path as following:
NodeB software: \\NodeB\Software\Software.cspBoot
BootROM: \\NodeB\Software\Firmware.csp
Data configuration file: \\NodeB\Configuration\NodeBCfg.xml
Make sure that each USB stick is only kept with 3 files above dedicatedly for one
NodeB, its better to label the USB stick with the site Name before commissioning to
avoid the USB sticks mixing if more than 1 site will be integrated for one team.
2009-05-15
HUAWEI Confidential
Page4, Total30
Security Level:
All employees must have a hard hat, hard hat must be worn at all times
when a tower crew is on site
Upon entry into the site one person must immediately call the security control
center and report what site you have entered, provide your name and you are
from Huawei, report site name and site number, report what your work order is
to be on site.
The security control center phone number, site name and site ID is posted
on the wall beside the phone
When you are last person in the site you must call security control and sign out
from the site before leaving.
You must take care and ensure that the lights are turned off, the shelter door is
locked and properly closed, shut the gate and close the gate lock.
HUAWEI Confidential
Page5, Total30
Security Level:
2009-05-15
HUAWEI Confidential
Page6, Total30
Security Level:
ALM LED
ON WMPT
HUAWEI Confidential
Page7, Total30
Security Level:
USB LED remains solidly ON. It will take about 10 minutes to activate the
software.
4. The DBS3900 will carry out a reset after the software and the data
configuration has been activated. During this process the LED on the USB will
transition from ON->OFF->Blinking; the RUN LED on WMPT transitions:
ON->OFF->Blinking (ON for 0.125s, OFF for 0.125s); RUN LED on the 2
WBBPb will blink respectively; CPRI LED on WBBPb will flash once RED
and then become Green. The full reset will take about 5 minutes.
5. After the reset is complete, DBS3900 runs normally, the status should now be:
LED on USB is OFF; RUN LED on WMPT blinks (ON for 1s, OFF for 1s);
ALM LED on WMPT stays OFF (If there are no alarms); RUN LED on
WBBPb blinks (ON for 1s, OFF for 1s);CPRI LED on WBBPb stays GREEN
2009-05-15
HUAWEI Confidential
Page8, Total30
Security Level:
During
Time
ON
Blinking
about 2sec
about
15min
ON
about
10min
about 5min
NodeB Running
ON->OFF>Blinking
Software Level
Dependant
Software Level
C01B051
C01B052
C01B053
2009-05-15
Page9, Total30
Security Level:
Note: WMPT always blinks slowly (ON for 1s, OFF for 1s) in 30 seconds, please plug
it again.
2009-05-15
HUAWEI Confidential
Page10, Total30
Security Level:
Connect
2. Set the IP address for laptop. You can log in to the NodeB on the LMT only
when the IP address of the LMT PC is correctly set. For local maintenance on
the LMT, the IP addresses of the LMT PC and the NodeB local maintenance
channel stay within the same network segment. You need set IP Address is
17.21.2.33 and mask is 255.255.0.0 in your laptop.
2009-05-15
HUAWEI Confidential
Page11, Total30
Security Level:
5. Click Add and Fill the table. The Office name is NODEB, the IP Address is
17.21.2.15 and the NE type is NodeB then click [Close].
6. Input the User Name: admin Password: NodeB. Click the Login
7. Once you are logged in successfully you should see the following.
2009-05-15
HUAWEI Confidential
Page12, Total30
Security Level:
2. The Software Update dialog box is now displayed, select Upgrade BOOTROM
and click [Next].
2009-05-15
HUAWEI Confidential
Page13, Total30
Security Level:
Note: NodeB Bootrom must be upgraded before upgrading NodeB Software; the
reversed procedure may cause the NodeB breakdown.
1. Select the Maintenance tab and choose Service > Software Management.
Then double-click Software Update, as before.
2. The Software Update dialog box is now displayed, this time select Upgrade
NodeB Software and click [Next]
2009-05-15
HUAWEI Confidential
Page14, Total30
Security Level:
3. The Upgrade NodeB software dialog box will not be displayed. Select
[Download NodeB Software Package], [Download By Configuration] and
[Activate NodeB Software] and then use the [Browse] button to set the location
of the NodeB Software Package, then click the [Next] button.
After the upgrade the software is complete, system will automatically reset
NodeB, this will take about 5 minutes.
2009-05-15
HUAWEI Confidential
Page15, Total30
Security Level:
Use the [Browse] button to set the location of the configuration file
(NodeBCfg.xml) and click [Start].
2. Once the progress bar reaches 100% click [Close]. Go to the MML command
window for the NodeB and type the command RST NODEB. Once the
NodeB has reset the new configuration will take effect. Please wait 5-10
minutes.
2009-05-15
HUAWEI Confidential
Page16, Total30
Security Level:
Then open the extra command file on your hard disk. Excution type is All
and dont select the prompt when error occurs.
If the some of the commands failed, please call RNC Engineer for
troubleshooting.
To finalize the commissioning of the NodeB and make it ready for call testing it is
necessary to notify the RNC engineer that the software upgrade and the
commissioning is complete. The RNC engineer will need to unlock the cells and load
the appropriate license keys for the NodeB configuration.
HUAWEI Confidential
Page17, Total30
Security Level:
LST VER
LST SOFTWARE
Pleae make sure the version is V200R010C01B053 and then you can make
callp. If it is not the right version, please do Item 10 Local Commissioning
again.
Log the results of the commands to a file and name it <Site
ID>_<SW_Version.txt>. This file will become part of the site
documentation package.
LED Status
Comments
WMPT
LED
WMPT Act LED
WBBPb Run LED
ON
Blinking (ON for 1s, OFF
for 1s)
Unless alarms are present
Alarm OFF
WBBPb
LED
WBBPb Act
CPRI LED
ON
ON
HUAWEI Confidential
Page18, Total30
Security Level:
this will form part of the site documentation to be submitted. Record the Primary
Scrambling Code for each cell in <Site ID>_CallP_Register.xls for Call_P test.
11.7 Troubleshooting
For assistance in troubleshooting any problems that arise during the commissioning
of the NodeB the first point of contact will be the RNC engineer for the area. If the
RNC engineer is not able to provide the necessary support the local engineer will
need to contact Huawei technical support.
2009-05-15
HUAWEI Confidential
Page19, Total30
Security Level:
Beta
Once the cell orientation has been verified then call testing can begin. ( Telus has
some special sites, which are not defined like this, Huawei will provide a list of these
kind of sites)
Call P testing is to be carried out with co-ordination with the RNC Engineer; there are
3 sections to the Call P process, which are:
Handover Tests
Please call RNC Engineer to check all cells are available. And then ask them to
block 800 Cells, you can make all the 1900 Calls and Handover
2009-05-15
HUAWEI Confidential
Page20, Total30
Security Level:
After you finish the 1900 call test, please call RNC Engineer to unblock 800 cells
and block 1900 cells, you can make 800 calls and Handover
After you finish the callp, please call RNC Engineer to unblock all cells and tell
them the Callp on site finished.
Record the all of the test results to <Site ID>_Telus_CallP Record after finished
each test.
PS: When you make the PS handover test, please remember to record the
average download speed to Telus_CallP Record spreadsheet.
Mobile to Fix line using 11 digits (Local Site telephone can be used for this
purpose)
Mobile to Fix line using 10 digits (Local Site telephone can be used for this
purpose)
Fix line to Mobile using 11 digits (Local Site telephone can be used for this
purpose)
Fix line to Mobile using 10 digits (Local Site telephone can be used for this
purpose)
13.3 Basic Service Tests and handover test (For you reference)
This section of call tests deals with testing the services on each cell of the Site, one of
each of the following tests is required in order to achieve a pass grade for the cells
(unless know conditions exist to prevent one or more of the tests, details of these
conditions must be detailed in the Call P documentation).
1. Call RNC Engineer to block all 850 cells. Then make Voice call and video call in
each 1900 cell. Make sure the PSC is right in each cell.
2. Make a call and walk around the site, to make sure there is no call drop. And then
reverse to make sure there is no call drop
2009-05-15
HUAWEI Confidential
Page21, Total30
Security Level:
3. 3. Call RNC Engineer to unblock 850 cells and block all 1900 Cells. Then make
Voice call and video call in each 850 cells. Make sure the PSC is right in each cell.
4. Make a PS download and walk around the site, to make sure there is no call drop.
And then reverse to make sure there is no call drop
Voice call to be held for 1 minute and checked for call quality.
Video Call to be held for 1 minute and checked for video and voice quality.
Initiate the internet connection and make sure connection is set up.
2.
3.
4.
2009-05-15
HUAWEI Confidential
Page22, Total30
Security Level:
2009-05-15
HUAWEI Confidential
Page23, Total30
Security Level:
Folder/Naming
Convention
Purpose
NodeB configuration
//<Site
ID>/Configuration/NodeBCf
g.xml
Check/<Site ID>_BBU
SN_<Serial Number>.txt
2009-05-15
HUAWEI Confidential
Page24, Total30
Security Level:
Site Software
versions
//<Site ID>/Commissioning
Log/<Site
ID>_SW_Version.txt
//<Site ID>/Commissioning
Log/<Site
ID>_Localcell_Status.txt
Cell Configuration
//<Site ID>/Commissioning
Log/<Site ID>_
Cells_Config.txt
Topology Snapshot
//<Site ID>/Commissioning
Log/<Site ID>_Topology.jpg
Alarm Snapshot
//<Site ID>/Commissioning
Log/<Site ID>_Alarms.jpg
Alarm Log
//<Site ID>/Commissioning
Log/<Site ID>_Alarms.csv
//<Site ID>/CallP
Register/<Site
ID>_Telus_CallP Record
//<Site ID>_Commissioning
Report
Call-p Result
Commissioning
Report
HUAWEI Confidential
Page25, Total30
Security Level:
2009-05-15
HUAWEI Confidential
Page26, Total30
Security Level:
Intra-Frequency Handover
S111:
1. [RNC engineer] Unblock the 3 cells of each sector.
2. [Site Engineer] Make sure mobile phone camp on the cell of sector Alpha,
originate a voice call to the 2nd mobile phone.
3. [Site Engineer] Hold on the call proceeding and move to the cell of sector Beta
and Gamma sequently in clockwise, then move to cell of sector Alpha.
4. [Site Engineer] Make sure the voice call is clear and without drop.
5. [Site Engineer] Hold on the call, move back to cell of sector Gamma and Beta
sequently in anti-clockwise, finally back to cell of sector Alpha.
6. [Site Engineer] Make sure the voice call is clear and without drop.
7. [Site Engineer] Terminate the call and confirm with RNC engineer for the test
results.
8. [Site Engineer] Record the test results in callp register table.
step3
step5
S222:
1. [RNC engineer] Unblock the 3 cells of F1 (850MHZ) of each sector, block the
other 3 cells of F2 (1900MHZ).
2. [Site Engineer]Follow the step2~8 for S111 handover test.
3. [RNC engineer] Block the 3 cells of F1 (850MHZ) of each sector, unblock the
other 3 cells of F2 (1900MHZ).
2009-05-15
HUAWEI Confidential
Page27, Total30
Security Level:
1. [RNC engineer] Unblock 850M cell (Alpha), 1900M cell (Beta) and
850M cell (Gamma).
2. [Site Engineer] Make sure mobile phone camp on the 850M cell (Alpha),
originate a voice call to the 2nd mobile phone.
3. [Site engineer] Hold on the call proceeding and move to the 1900M cell (Beta)
in clockwise.
4. [Site Engineer] Make sure the voice call is clear and without drop.
5. [Site Engineer] Confirm with RNC engineer for the successful handover to
1900M cell (Beta) and move to 850M cell (Gamma).
6. [RNC Engineer] Block 850M cell (Alpha), unblock 1900M cell (Alpha).
7. [Site Engineer] Confirm with RNC engineer for the successful handover to
850M cell (Gamma) and move to 1900M cell (Alpha).
8. [RNC Engineer] Block 1900M cell (Beta), unblock 850M cell (Beta).
9. [Site Engineer] Confirm with RNC engineer for the successful handover to
1900M cell (Alpha) and move to 850M cell (Beta).
10. [RNC Engineer] Block 850M cell (Gamma), unblock 1900M cell (Gamma).
11. [Site Engineer] Confirm with RNC engineer for the successful handover to
850M cell (Beta) and move to 1900M cell (Gamma).
12. [RNC Engineer] Block 1900M cell (Alpha), unblock 850M cell (Alpha).
13. [Site Engineer] Confirm with RNC engineer for the successful handover to
1900M cell (Gamma) and move to 850M cell (Alpha).
14. [Site Engineer] Confirm with RNC engineer for the successful handover to
850M cell (Alpha) and move back to1900M cell (Gamma) in anti-clockwise.
15. [Site Engineer] Confirm with RNC engineer for the successful handover to
1900M cell (Gamma) and move to 850M cell (Beta) in anti-clockwise.
16. [RNC Engineer] Block 850M cell (Alpha), unblock 1900M cell (Alpha).
17. [Site Engineer] Confirm with RNC engineer for the successful handover to
850M cell (Beta) and move to 1900M cell (Alpha) in anti-clockwise.
18. [RNC Engineer] Block 1900M cell (Gamma), unblock 850M cell (Gamma).
19. [Site Engineer] Confirm with RNC engineer for the successful handover to
1900M cell (Alpha) and move to 850M cell (Gamma) in anti-clockwise.
20. [RNC Engineer] Block 850M cell (Beta), unblock 1900M cell (Beta).
2009-05-15
HUAWEI Confidential
Page28, Total30
Security Level:
21. [Site Engineer] Confirm with RNC engineer for the successful handover to
850M cell (Gamma) and move to 1900M cell (Beta) in anti-clockwise.
22. [RNC Engineer] Block 1900M cell (Alpha), unblock 85M cell (Alpha).
23. [Site Engineer] Confirm with RNC engineer for the successful handover to
1900M cell (Beta) and move to 850M cell (Alpha) in anti-clockwise.
24. [Site Engineer] Confirm with RNC engineer for the successful handover to
850M cell (Alpha).
25. [Site Engineer] Terminate the call and confirm with RNC engineer for the test
results.
26. [Site Engineer] Record the test results in Callp register table.
2009-05-15
HUAWEI Confidential
Page29, Total30
2009-05-15
HUAWEI Confidential
Security Level:
Page30, Total30