Escolar Documentos
Profissional Documentos
Cultura Documentos
REB500 /
REB500sys
Technology
REB500_basics / 2005-04-14 / RW
BASICS
ABB
Block diagram
Internal Communication
User Tool HMI500 (REBWIN)
(Pre-) Configuration and addressing Tool REBLOAD
ABB
Definitions / Features
REB500sys
REB500
System
REB500_basics / 2005-04-14 / RW
CU01 / CU02
ABB
Development
Central Unit
REB500_basics / 2005-04-14 / RW
Central Unit 01
Central Unit 02
1994 - 2003
Central Unit 03
since 2004
Bay Unit
Firmware Version
BU01
1994 - 2000
V4.xx
BU02
2000 - 2003
V5.xx
BU03
since 2001
V6.xx
since
2004
V7.xx
ABB
Single Busbar
Double Busbar
Triple Busbar
Quadruple Busbar
1 Breaker
System
Transfer Bus
Functionality
BBP
REB500_basics / 2005-04-14 / RW
DR
I0
EFP
OC
U<
PD
ER
COM
HMI
Central Unit
12 Binary Inputs
9 Binary Outputs
Bay Unit
(BU02)
16 Binary Inputs,
16 Binary Outputs
4 Current Transformer (1A & 5A)
Maximum
Configuration
ABB Switzerland Ltd. - 5
BFP
Abbreviations:
OC = Overcurrent Protection
PD = Pole discrepancy Protection
I0 = Neutral Current Detection
Com = Communication
HMI = Human Maschine Interface
ABB
BBP
DR
1.5 sec
ER
(Remote)
HMI
REB500_basics / 2005-04-14 / RW
Test
generator
Option
BFP
EFP
I>
I>
Logik
U>
U<
OC
PD
COM
SA
DR
10 sec
I>>
50
T
49
Z<
U<
EF
WE
I
87T
SYN
ABB
REB500_basics / 2005-04-14 / RW
TP since FW
I>
I>
U>
Logik
U<
Basic functions
Version
7.20
T
49
I
87T
I>>
50
ABB
Hardware Distribution
Fibre Optical
connection
one CENTRAL
UNIT (CU)
C
E
REB500_basics / 2005-04-14 / RW
Units
Bay
Units
Bay
Units
Bay
Units
Bay
ABB
Hardware Distribution
= decentralised system
general In- and Outputs
(e.g. reset, alarms)
C
E
REB500_basics / 2005-04-14 / RW
Units
Bay
Units
Bay
Units
Bay
Units
Bay
ABB
CU
C
E
BU
C
REB500_basics / 2005-04-14 / RW
Units
Bay
BU
BU
E
Units
Bay
BU
C
Units
Bay
Units
Bay
ABB
REB500_basics / 2005-04-14 / RW
Busbar Protection
Intertripping
Event Recording
Monitoring
Supervision
Selfsupervision
Local indication
PC interface
BU01 /
Signal processing
(filtering etc.)
BU02
Breaker Failure Protection
End Fault Protection
Event Recording
Disturbance Rec.
Monitoring
Supervision
Selfsupervision
Local indication
PC interface
CU
C
E
Units
Bay
BU
BU
C
Units
Bay
BU
C
Units
Bay
Units
Bay
ABB
REB500_basics / 2005-04-14 / RW
Busbar Protection
Intertripping
Event Recording
Monitoring
Supervision
Selfsupervision
Local indication
PC interface
CU
C
E
Units
Bay
BU
BU
C
Units
Bay
BU
C
Units
Bay
BU03
Signal processing
(filtering etc.)
Breaker Failure Protection
End Fault Protection
Line Protection
Cable Protection
Auto-reclosure
Synchrocheck
Tripping (logic)
Transformer Protection
Event Recording
Disturbance Rec.
Monitoring
Supervision
C
Selfsupervision
E
Local indication
PC interface
Units
Bay
ABB
(for FW Vers. 6)
1/3 19 Rack
REB500_basics / 2005-04-14 / RW
Rear view
Front view
ABB
(for FW Vers. 6)
Current
Transformers
Optical Connection
to Central Unit
Inputs
1
2
3
2
OC01
3
OC02
6
7
OPTION
OC03
11
14
15
18
OC05
10
5
7
Inputs
OC07
1
2
3
4
OC09
OC10
CR01
OC12
CR02
5
6
8
9
OC13
12
13
14
OC15
17
18
CR08
CR09
CR10
OC16
OC18
CR04
5
CR05
9
10
11
12
CR14
13
CR15
14
CR16
15
11
12
13
CR06
CR13
OC20
20 Binary Inputs
24 250 VDC
Adjustable via SW
CR07
14
15
12
I0
U4
0
11
Power Supply
13
P
U5
10
CR12
OC19
CR03
7
CR11
11
10
OC17
15
16
OC14
10
11
Outputs
I3
U3
2
3
OC11
I2
U2
Outputs
OC06
REB500_basics / 2005-04-14 / RW
6
7
16
17
U1
OC04
OC08
I1
12
13
Voltage
Transformers
10
4
5
14
Redundant Power
Supply (option)
4 CTs 1 or 5 A
Ratio adjustable
2
via SW
&
5 VTs
Power supply
Ratio adjustable
via SW
&
Red. Power Supply
R
16 Binary Outputs
+
-
ABB
1/3 19 Rack
REB500_basics / 2005-04-14 / RW
Rear view
Front view
ABB
2
3
Current
Transformers
1/3 19 Rack
6
7
2
3
OC02
11
1
2
OC03
OC04
15
Outputs
Inputs
OC07
1
2
3
17
7
8
9
CR01
OC11
OC12
Outputs
CR02
OC13
11
12
13
14
OC15
17
18
2
CR08
CR09
CR10
OC16
I2
I5
I3
OC18
20 Binary Inputs
24 250 VDC
Adjustable via SW
13
14
15
9
10
CR04
7
8
CR12
CR13
10
11
OC20
12
12
CR14
13
CR15
14
CR16
15
CR05
11
12
13
CR06
CR07
14
15
I6
0
11
CR11
OC19
CR03
10
OC17
15
16
OC14
10
REB500_basics / 2005-04-14 / RW
OC10
5
6
OC09
16
18
I4
OC06
OC08
I1
OC05
12
14
Current Transformer
1
13
10
OC01
4
5
I7
0
1
5
I8
0
Power Supply
16
17
18
I9
0
3 CTs 1 or 5 A
Ratio adjustable
via SW
&
6 CTs 1 or 5 A
Power supply
Ratio adjustable
via SW
&
Power supply
R
1
+
_
16 Binary Outputs
ABB
1/3 19 Rack
REB500_basics / 2005-04-14 / RW
Rear view
Front view
ABB
Optical Connection
to Central Unit
A1
OC01
2
3
A2
OC02
1
5
A3
A4
Voltage Transformers
OPTION
A5
U 1
OC03
UL1
A6
OC04
A8
A9
1
A10
CR01
OC06
B1
A12
CR02
OC08
B5
OC11
CR09
CR10
B6
CR04
OC12
B7
OC14
B11
11
CR11
CR06
12
CR12
CR13
13
CR07
14
10
CR08
15
B12
B13
OC15
11
12
B14
OC16
B15
16 Binary Inputs
24 250 VDC
Adjustable via SW
CR14
13
CR15
14
CR16
15
UL0
11
CR05
OC13
B10
B9
12
I0
10
Power Supply
Redundant
Power Supply
10
B8
7
CR03
11
5
6
B4
UL3
8
B2
B3
A14
REB500_basics / 2005-04-14 / RW
I3
4
OC10
2
3
A13
A15
OC09
OC07
10
UL2
OC05
I2
A7
A11
I1
R 1
4 CTs 1 or 5 A
Ratio adjustable
500UTM01
via SW
&
4 VTs
Power supply
Ratio adjustable
via SW
&
Red. Power Supply
16 Binary Outputs
ABB
1/2 19 Rack
REB500_basics / 2005-04-14 / RW
Rear view
Front view
ABB
1
2
3
I1
4 CTs 1 or 5 A
Ratio adjustable
via SW
OPTION
Binary Inputs
Binary Outputs
8
9
10
1
5
I3
2
3
11
12
4
I0
500MTM01
Voltage
Transformers
U 1
5
6
8
9
10
11
12
500PSM01
UL2
5
REB500_basics / 2005-04-14 / RW
Optical Connection
to Central Unit on
15
500AIP01
UL3
8
13
14
OC01
OC02
OC03
OC04
CR01
4
CR02
5
7
8
16
17
18
OC05
OC06
OC07
OC01
OC021
2
OC03
OC044
CR01
CR02
CR03
CR03
CR04
UL1
+
Binary Outputs
I2
1
Binary Inputs
10
CR05
11
12
OC08
13
CR06
14
OC09
OC10
CR04
OC05
OC06
OC07
CR05
10
9
10
OC089
11
CR06
12
13
OC0911
12
14
OC1013
15
15
OC1114
CR07
16
15
CR08
CR09
OC12
OC11
17
CR07
OC12
CR08 500BIO01 17
CR09
18
18
16
16
17
18
500BIO01
500BIO01
10
UL0
11
500MTM01
12 Binary Inputs
24 250 VDC
Adjustable via SW
9 Binary
Outputs
ABB
BU02
BU03 - LP
V.4.xx
V.5.xx
12 + 12 (as
Option)
16
20 with other
ground conn.
20 with other
ground conn.
9 + 9 (as Option)
16
16
16
CT
VT
no
yes
yes
yes
20
20
Power of P
++
+++
+++
FW Version
OC Inputs
REB500_basics / 2005-04-14 / RW
CR Outputs
BU03 - TP
V.7.20
ABB
ABB
REB500_basics / 2005-04-14 / RW
progammable LEDs
Front view
(without modules)
ABB
REB500_basics / 2005-04-14 / RW
16
17
18
19
20
21
PSM
CPU CPC
CPU MBA
Bus Administrator
(for 20 BUs)
CIM
Communication Interface
Modul (for SAS / SMS)
SCM
BIO
PSM
15
CIM
14
BIO
13
BIO
12
SCM
11
SCM
10
CPU CPC
SCM
CPU MBA
SCM
SCM
CPU MBA
SCM
CPU CPC
PSM
SLOT: 1
CPU CPC
CPU Module
ABB
REB500_basics / 2005-04-14 / RW
16
17
18
19
20
21
PSM
15
CIM
14
BIO
13
BIO
12
SCM
11
SCM
10
CPU CPC
SCM
CPU MBA
SCM
SCM
CPU MBA
SCM
CPU CPC
PSM
SLOT: 1
CPU CPC
01 05 BUs
06 10 BUs
11 15 BUs
16 20 BUs
21 25 BUs
25 30 BUs
Option
ABB
REB500_basics / 2005-04-14 / RW
ABB
6)
19 Rack
REB500_basics / 2005-04-14 / RW
Rear view
Front view
(without modules)
ABB
6)
Rear view
(equipped with Modules for 4 BUs)
PSM
CMP
CSP
16
17
18
19
20
TRM
MBA
SBA
CIM
Communication Interface
Modul (for SAS / SMS)
SCM
BIO
21
PSM
15
BIO
14
BIO
13
SCM
12
SCM
11
SCM
10
TRM
CIM +
SCM
SBA
MBA
CSP +
TRM
CMP +
PSM
REB500_basics / 2005-04-14 / RW
SLOT: 1
TRM
(fr BU 10-18)
CPU Module
ABB
16
17
18
19
20
21
PSM
15
BIO
14
BIO
13
SCM
12
SCM
11
SCM
10
TRM
CIM +
SCM
SBA
MBA
CSP +
TRM
CMP +
PSM
REB500_basics / 2005-04-14 / RW
SLOT: 1
TRM
01 04 BUs
05 9 BUs
10 13 BUs
14 18 BUs
Option
ABB
REB500_basics / 2005-04-14 / RW
40 - 59 Bay Units
ABB
Local HMI
Monitoring of
Alarms
Events
Settings / Adjustments
Measurements
Reset possibility
for trips & alarms
Interface to PC (with user
program HMI500)
REB500_basics / 2005-04-14 / RW
3 Status indications
(in service, alarm, trip)
20 free programmable LEDs
(only at BU for REB500sys)
ABB
REB500_basics / 2005-04-14 / RW
flexible installation
(for central
installation)
ABB
Central unit
REB500_basics / 2005-04-14 / RW
Bay unit
Central Version
De-central Version
ABB
mage
Isolator I
Q1
Q2
rip
CB T
Q0
REB500_basics / 2005-04-14 / RW
T1
T5
ection
n
n
o
C
CT
ection
n
n
o
C
VT
Front views
ABB
REB500_basics / 2005-04-14 / RW
Line Protection
BU 1
Transformer Protection
BU 2
Line Protection
BU 3
ABB
BU 1 3
CU
BU 4 6
REB500_basics / 2005-04-14 / RW
BU 7 9
BU 10 12
ABB
BU 1 3
CU
REB500_basics / 2005-04-14 / RW
BU 4 6
Spare
Feeder
BU 7 8
+ Spare Feeder
ABB
REB500_basics / 2005-04-14 / RW
Spare
Feeder
Dummy
ABB
REB500_basics / 2005-04-14 / RW
Push- Button
Blocking- Switch
Reset of TRIP /
ALARM
Accept isolator
image alarm
ABB
REB500_basics / 2005-04-14 / RW
Panel Wiring
ABB
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
T1
Q0
Q0
Q0
T1
T1
T1
Q0
Q0
Q0
Q0
Q0
T1
T1
T1
T1
HMI500
with TCP/IP
Substation
Automation or
Monitoring Systems
e.g.: SAS5xx or SMS530
HMI500
with LON
1
2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
T1
Q0
Q0
Q0
T1
T1
T1
Q0
1
2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
REB500_basics / 2005-04-14 / RW
T1
Q0
Q0
Q0
T1
T1
T1
Q0
Q0
Q0
Q0
Q0
T1
T1
T1
T1
Q0
Q0
Q0
Q0
T1
T1
T1
T1
12
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
Q1
Q2
T1
Modem
Local Connection
on BU or CU
Q0
Q0
Q0
T1
T1
T1
Q0
Q0
Q0
Q0
Q0
T1
T1
T1
T1
Modem
ABB
Bay unit
Central unit
Optical
Interface
DC
Real
time
clock
DC
Database
stored in
EEPROM
SCS/SMS
Interface
RS 232
Interface
DC
DC
CPU
Local
HMI
DSP
A/D
MUX
S/H
CPU
Modul
DP
Mem.
CIM
Binary In-/Out
registers
C
E
Filter
Datenbank
gespeichert
im EEPROM
Filter
REB500_basics / 2005-04-14 / RW
Star
coupler
Electrical
insulation
CPU
Modul
Binary
In/Out
CPU
Modul
Bus
admin.
Star
coupler
FO connection to
other Bay Units
ABB
Bay unit
Central unit
Optical
Interface
DC
Real
time
clock
DC
Database
stored in
EEPROM
SCS/SMS
Interface
RS 232
Interface
DC
DC
CPU
Local
HMI
DSP
A/D
MUX
S/H
CPU
Modul
DP
Mem.
CIM
Binary In-/Out
registers
C
E
Filter
Datenbank
gespeichert
im EEPROM
Filter
Bus
REB500_basics / 2005-04-14 / RW
admin.
Electrical
insulation
Star
coupler
CPU
Modul
Binary
In/Out
CPU
Modul
Bus
admin.
Star
coupler
FO connection to
other Bay Units
ABB
Bay unit
Central unit
Optical
Interface
DC
Real
time
clock
DC
Database
stored in
RAM
SCS/SMS
Interface
RS 232
Interface
DC
DC
CPU
Local
HMI
DSP
A/D
MUX
S/H
CPU
Modul
DP
Mem.
CIM
Binary In-/Out
registers
C
E
Filter
Datenbank
gespeichert
im EEPROM
Filter
Bus
REB500_basics / 2005-04-14 / RW
admin.
Electrical
insulation
Star
coupler
CPU
Modul
Binary
In/Out
CPU
Modul
Bus
admin.
Star
coupler
FO connection to
other Bay Units
ABB
Bay unit
Optical
Interface
500AIP01
500BIO01
500BIO01
Central unit
Real
time
clock
Prozessbus
Bus
Interface
C
E
Bus
Interface
Bus
Interface
SCS/SMS
Interface
RS 232
Interface
DC
DC
CPU
Modul
Local
HMI
CIM
DSP
A/D
MUX
S/H
CPU
CPU
CPU
Database
stored in
RAM
Filter
Binary In-/Out
registers
Filter
Binary In-/Out
registers
Datenbank
gespeichert
im EEPROM
CPU
Modul
CPU
Modul
Filter
Bus
admin.
Star
coupler
Binary
In/Out
Bus
admin.
Star
coupler
REB500_basics / 2005-04-14 / RW
DC
DC
500PSM01
Electrical
insulation
500MTM01
FO connection to
other Bay Units
ABB
Standalone Operation
BU01
BU02
BU03
BU03
V.4.xx
V.5.xx
V.6.xx
V.7.xx
100% Standalone
no
no
no
yes
Standalone with
CommunicationAlarm (e.g. for
commissioning)
no
no
yes
yes
Standalone after
start- up on the CU
(with
CommunicationAlarm )
yes
yes
yes
yes
REB500_basics / 2005-04-14 / RW
FW Version
ABB
Communication
fibre
optical
cable
BU
C
Units
Bay
BU
BU
E
Units
Bay
BU
C
Units
Bay
Units
Bay
REB500_basics / 2005-04-14 / RW
synchron bus
guaranteed maximum signal running time
defined maximum reactions time
FAST & SAVE
ABB
Communication
MVB Bus
Source address - sender information
Periodic Phase
Sporadic Phase
Base Periode
REB500_basics / 2005-04-14 / RW
Periodic Phase
Process data
- Analogue Values
- Busbar Replica
- Trip commands
Periodic Phase
Sporadic Phase
Base Periode
Sporadic Phase
Information Data
- Disturbance Recorder
- Events
Supervision Data
- Self- Supervision
- Diagnosis
- Synchronisation
ABB
Communication - Addressing
REB500_basics / 2005-04-14 / RW
Device ID:
address of the Device (MVB)
ABB
Communication - Addressing
Node ID:
Device ID:
MVB
Optical
Interface
DC
Real
time
clock
DC
Database
stored in
EEPROM
SCS/SMS
Interface
DC
RS 232
Interface
DC
CPU
C
E
4
Local
HMI
DSP
A/D
MUX
S/H
CPU
Modul
DP
Mem.
Binary In-/Out
registers
C
Filter
Database
stored in
EEPROM
REB500_basics / 2005-04-14 / RW
admin.
Electrical
insulation
VME
CPU
Modul
CPU
Modul
2
1
MVB
MVB
Bus
Bay unit
CIM
Filter
Star
coupler
Binary
In/Out
Bus
Star
coupler
admin.
Central unit
FO connection
to other Bay
Units
1
5 - x
1st BIO
2nd
BIO
2 - x
ABB
Q1 Q2
T1
Q0
Q0
T1
Q0
T1
REB500_basics / 2005-04-14 / RW
Bay unit
local
connection on
the
Bay Unit
Bay unit
local
connection
on the
Central Unit
ABB
REB500_basics / 2005-04-14 / RW
ABB
Exception !!!
REB500_basics / 2005-04-14 / RW
Bay unit
Bay unit
local connection
on the
Bay Unit
ABB
REB500_basics / 2005-04-14 / RW
Bay unit
local
connection on
the
Bay Unit
Bay unit
ABB
Bay unit
Bay unit
REB500_basics / 2005-04-14 / RW
local connection
on the
Central Unit
local
connection on
the
Bay Unit
ABB
REB500_basics / 2005-04-14 / RW
ABB
REB500_basics / 2005-04-14 / RW
ABB