Jabal Al Ka'aba Hotel

( GF +MF+3Parking Floor+Restaurant Floor+Service Floor+Prayer Floor+17 floors+ roof )

Jabal Al-Ka'aba Hotle - KSA

Haret Al Bab, Jabal Al-Ka'aba - Kingdoaudi Arabiam of Saudi Arabia

Index

Bills of Quantities & Dayworks


Contents

Pages

Preambles

P/1 to P/20

General Requirements

B1/1 to B1/12

Site Work

B2/1 to B2/4

Concrete Work

B3/1 to B3/6

Masonry

B4/1 to B4/3

Metal Work

B5/1 to B5/3

Thermal & Moisture Protection

B6/1 to B6/5

Doors & Windows

B7/1 to B7/7

Finishes

B8/1 to B8/11

Specialists

B9/1 to B9/4

Mechanical Engineering Installations

B10/1 to B10/14

Electrical Engineering Installations

B11/1 to B11/1

Provisional Sums

B12/1 to B12/6

Grand Summary

GS/1 to GS/1

Dayworks

DW/1 to DW/6

Bills of Quantities and Dayworks

1/81

Index

Bills of Quantities and Dayworks

2/81

Jabal Al-Ka'aba Hotel

Item

Item Description

Quantity

Unit

Rate

GENERAL REQUIREMENTS
TENDER and CONTRACT
This is a fixed priced Lump sum contract as described in
the conditons of Tender & Contract, Rates filled in by the
tenderer againts items in this document deemed to include
for Escalation and all items of works required and so
necessary to complete the project, to the satisfaction of
Engineer and Employer based on the drawings,
specifications and all other guidance / documents provided.
Tenderer shall check and satisfy himself with the
correctness and completeness of the documents provided
and the accuracy of the quantities provided in the BOQ. No
claims for such an error or mistake in quantities will be
accepted except if such an item indicates an alterations and
modifications.

Note

Generally

Access to and possession or use of the site


Refer to Clause 42.1 of Tender and Contract Conditions

Item

500,000

Item

250,000

Item

100,000

Item

300,000

Item

250,000

Site Administration
The Contractor shall provide sufficient staff and equipment
to perform the administrative duties in executing the
Contract

Day

1,500

Site Supervision
The whole of the Works shall be under full time supervision
of the Contractor

Day

2,500

Limitations of Working Space


Working space on Site is subject to the reasonable
limitations imposed by the Engineer
Limitations of Working Hours
Refer to Clause 45.1 of Tender and Contract Conditions
Maintenance of existing services on, under or over the site

The Contractor shall be responsible for maintaining and


protecting all existing services as specified
Permits
The contractor shall be responsible for obtaining the
Necessary Permits from the Local Authorities including all
payment fees.
GENERAL REQUIREMENTS (Cont'd)
CONTRACTOR'S ADMINISTRATIVE

B1-General Requirements

Bills of Quantities and Dayworks

B1/3

Jabal Al-Ka'aba Hotel

Security
The Contractor shall protect the Site and works from
unauthorized entry and fire and shall control his labour
force to prevent nuisance or trespass onto adjacent
property

Day

1,500

Safety, Health and Welfare of Workpeople


The Contractor, and all persons employed by him on Site
shall comply with all Acts, Orders, Laws and regulations
concerning the safety, health or welfare of workpeople

Day

3,000

Transport of Workpeople
The Contractor shall make all necessary arrangements for
the transport of his own, and his sub-contractor's
employees for the duration of the Works

Day

5,000

CONSTRUCTIONAL PLANT
Generally
The Contractor shall allow for all necessary
Small plant and tools

Item

1,500,000

Scaffolding
Establishment

Item

10,000,000

Maintenance

Day

25,000

Removal & making good the site

Item

250,000

GENERAL REQUIREMENTS (Cont'd)

Cranes and lifting plant


Establishment

Item

5,000,000

Maintenance

Day

25,000

Removal & making good the site

Item

4,000

Site Transport
Establishment

Item

5,000

Maintenance

Day

3,000

Removal & making good the site

Item

250,000

Plant required for specific trades


Establishment

Item

1,500,000

Maintenance

Day

5,000

Removal & making good the site

Item

250,000

EMPLOYER'S / ENGINEER'S FACILITIES


The Contractor shall allow for the Employer's/Engineer's/
their representative's office facilities and services as per
Division 1 - General Requirement and the following.

B1-General Requirements

Bills of Quantities and Dayworks

B1/4

Jabal Al-Ka'aba Hotel

Provide temporary office accommodation including all


furnishings, fittings, shaded car parking spaces and related
facilities as per specification.
J

Establishment

Item

1,500,000

Maintenance

Day

5,000

Removal and making good the site

Item

250,000

GENERAL REQUIREMENTS (Cont'd)


EMPLOYER'S / ENGINEER'S FACILITIES
A

Provide computers, Printers & Photocopying machine for


the exclusive use of the Engineer and his representatives as
per Division 1 - General Requirement.

Item

500,000

Provide first aid cabinet with supplies

Item

50,000

Provide stationery consumables & other consumables as


per Division 1 - General Requirement.

Item

150,000

Provide Telephones, internet and facsimile for the exclusive


use of the Engineer and his representatives as per Division
1 - General Requirements.
D

Establishment

Item

250,000

Maintenance

Day

3,000

Removal & making good the site

Item

100,000

The contractor shall provide Mobile Internet Data Card


USB Modem and mobile telephone with sim card, for the
use of the Engineer's Representative, charges to be paid by
the Contractor. Telephones to have local dialing facility
only as specified.

Day

1,000

Day

1,500

Secretary
Provide full time office secretary for the use of the Engineer
& his Representative.

GENERAL REQUIREMENTS (Cont'd)


EMPLOYER'S / ENGINEER'S FACILITIES

Vehicle
Provide 2 Nos. four wheel drive vehicle including
maintenance and the like.

Day

2,500

Attendance of Staff
Provide a full time office attendant including cleaning for
the sole use of the Engineer and his representatives.

Day

1,000

B1-General Requirements

Bills of Quantities and Dayworks

B1/5

Jabal Al-Ka'aba Hotel

Equipment
Provide survey Instruments and protective clothings as
required by the Engineer and his representative.

Item

250,000

Progress Photographs
Supply and hand over set of progress photographs as per
Division 1 - General Requirements.

Item

150,000

Progress Reports
Provide weekly & monthly progress reports as per Division
1 - General Requirements

Item

300,000

Sign Boards
fabricate, erect and maintain sign boars as per specification
and drawings including removal from site.
F

Establishment

Item

50,000

Maintenance

Day

2,000

Removal & making good the site

Item

15,000

GENERAL REQUIREMENTS (Cont'd)


CONTRACTOR'S FACILITIES
Generally
The Contractor shall allow for the following Contractor's
facilities
Provide accommodation and buildings, including offices,
compounds, stores, mess rooms, laboratories and the like as
specified
A

Establishment

Item

2,000,000

Maintenance

Day

15,000

Removal & making good the site

Item

150,000

Note

1,000,000

Labor Camp
Labor Camp is not permitted within the Site area or within
the Contractor's site compound. Watchmen and security
staff only may be accommodated subject to the approval of
the Engineer.

Provide temporary roads, including hard standings and


crossings
D

Establishment

Item

400,000

Maintenance

Day

10,000

Removal & making good the site

Item

350,000

B1-General Requirements

Bills of Quantities and Dayworks

B1/6

Jabal Al-Ka'aba Hotel

H
I

Water for the works


The Contractor shall supply clean water for the Works and
pay all fees for connection and consumption.
Lighting and Power for the Works
The Contractor shall supply lighting and power for the
works and pay all fees for connection and consumption.
Provide temporary telephones for the works

Item

500,000

Item

800,000

Item

250,000

GENERAL REQUIREMENTS (Cont'd)


CONTRACTOR'S FACILITIES
Temporary Works
The Contractor shall allow for the following temporary
works, including:
A

Provide access roads as required and remove on completion

Item

300,000

Traffic Diversion
Provide all temporary diversions of vehicular and
pedestrian traffic if required

Item

100,000

Provide all temporary works, traffic control signals, signs,


marking and lighting required throughout the site

Item

60,000

Co-ordination with service authorities

Item

150,000

Fencing and Hoarding


Supply, install and maintain fencing and hording including
gates and barriers as per Master Developers requirements
and details provided and including removal from site.

Establishment

Item

650,000

Maintenance

Day

5,000

Removal & making good the site

Item

200,000

GENERAL REQUIREMENTS (Cont'd)


SUNDRY ITEMS
Generally
The Contractor shall allow for all necessary sundry items,
including:
A

The Contractor shall comply with all traffic regulations


and shall liaise with the Police and other authorities with
jurisdiction over traffic movement

Item

200,000

Maintain public and private roads, as specified

Item

50,000

B1-General Requirements

Bills of Quantities and Dayworks

B1/7

Jabal Al-Ka'aba Hotel


C

The Contractor shall provide for drying out the works


during construction; maintain the level of humidity of the
works as necessary for the proper incorporation of
materials

Item

1,500,000

The Contractor shall ensure that excessive noise and


pollution does not occur during the execution of the works.

Item

250,000

The Contractor shall provide all necessary attendance to


statutory authorities as may be required for the completion
of the works.

Item

200,000

The Contractor shall comply with all statutory obligations

Item

150,000

The Contractor shall allow for testing of materials to


include providing all testing, transportation and assistance
as specified in the contract for site inspection

Item

600,000

The Contractor shall remove rubbish at regular intervals,


provide protective casings and coverings and clean the
works at completion

Item

250,000

GENERAL REQUIREMENTS (Cont'd)


SUNDRY ITEMS (Cont'd)
A

The Contractor shall protect the works from inclement


weather

Item

150,000

The contractor shall allow for testing of works in


accordance with specification

Item

100,000

The contractor shall provide the engineer sample of goods /


materials and spares for maintenance as specified

Item

50,000

The Contractor shall provide shop drawings as specified

Item

250,000

The Contractor shall provide As-built drawings and O&M


manuals as specified

Item

250,000

Allow for QA/QC Engineer service and Quality Control


procedures

Item

300,000

As soon as the Contract has been signed, the Contractor


shall check and record the existing ground and / or made
up levels. Permanent datum point must be established
during this operation to the approval of the Engineer. A
Topographical Survey Report will be issued to Tenderers
before return of Tenders.

Item

200,000

B1-General Requirements

Bills of Quantities and Dayworks

B1/8

Jabal Al-Ka'aba Hotel


H

A full copy of the soil investigation report issued with the


tender for information only. The Contractor will be deemed
to have examined the report, familiarized himself with the
site, satisfied himself as to the nature of the ground and
subsoil and carried out ny test/investigation/design
necessary for the works.

Item

100,000

The contractor shall allow for complying with all local


authority regulations and NOC requirements and all
requirements of the project specifications.

Item

250,000

Item

50,000

GENERAL REQUIREMENTS (Cont'd)


SUNDRY ITEMS (Cont'd)
A

The Contractor shall provide a temporary first aid post


property equipped and manned by competent person. The
facility shall display a large red cresent and prominent
lettering "FIRST AID" in English & Arabic, in red on a
white background.
CONDITIONS OF CONTRACT
PERFORMANCE SECURITY / INSURANCE

Security
Performance Security in accordance with Conditions of
Contract, Clause 10.1

Item

100,000

Insurances
For the works in accordance with Conditions of Contract,
Clause 21

Item

500,000

Third party in accordance with Condition of Contract,


Clause 23

Item

200,000

Workers Compensation in accordance with Conditions of


Contract, Clause 24

Item

150,000

Item

200,000

Item

250,000

Conditions of Contract
The Contractor to list and price for all costs associated with
compliance with the Conditions of Contract and not
covered elsewhere (details to be provided).
1
2
3

Specification
The Contractor to list and price for all costs associated with
compliance with the Conditions of Contract and not
covered elsewhere (details to be provided).
1
2
3

B1-General Requirements

Bills of Quantities and Dayworks

B1/9

Jabal Al-Ka'aba Hotel


GENERAL REQUIREMENTS (Cont'd)
Additional Items
The tenderer is to detail below any additional items with
quantities and rates not previously included to complete the
build up of the lump sum tender price for this section of the
works. Should the tenderer fail to insert any items here, it
will be deeme

GENERAL REQUIRMENTS
Collection
Page B1/1
Page B1/2
Page B1/3
Page B1/4
Page B1/5
Page B1/6
Page B1/7
Page B1/8
Page B1/9
Page B1/10
Page B1/11

B1-General Requirements

Bills of Quantities and Dayworks

B1/10

Jabal Al-Ka'aba Hotel

Total of Bill No. 1 - GENERAL REQUIREMENTS


To The Grand Summary

B1-General Requirements

Bills of Quantities and Dayworks

SAR

B1/11

Jabal Al-Ka'aba Hotel

Amount : SAR

500,000
0
0
0
250,000
0
0
100,000
0
0
300,000
0
0
250,000

0
0
0
0
0
0
1,500

0
0
2,500
0
B1-General Requirements

Bills of Quantities and Dayworks

B1/12

Jabal Al-Ka'aba Hotel


0
1,500

0
0
3,000

0
0
5,000

0
0
0
0
1,500,000
0
0
10,000,000
0
25,000
0
250,000
0
0
0
0
5,000,000
0
25,000
0
4,000
0
0
5,000
0
3,000
0
250,000
0
0
1,500,000
0
5,000
0
250,000
0
0
0
0

B1-General Requirements

Bills of Quantities and Dayworks

B1/13

Jabal Al-Ka'aba Hotel


0
0

0
1,500,000
0
5,000
0
250,000
0
0
0
0
0
0
500,000

0
50,000
0
150,000
0
0

0
250,000
0
3,000
0
100,000
0
1,000

0
0
1,500
0
0
0
0
0
0
0
2,500
0
0
1,000
B1-General Requirements

Bills of Quantities and Dayworks

B1/14

Jabal Al-Ka'aba Hotel


0
0
250,000
0
0
150,000
0
0
300,000
0
0
0
0
50,000
0
2,000
0
15,000
0
0
0
0
0
0
0
0
0
0
0

0
2,000,000
0
15,000
0
150,000
0
0
1,000,000

0
0
0
400,000
0
10,000
0
350,000
B1-General Requirements

Bills of Quantities and Dayworks

B1/15

Jabal Al-Ka'aba Hotel


0
0
500,000
0
0
800,000
250,000
0
0
0
0
0
0
0
0
0
300,000
0
0
100,000
0
60,000
0
150,000
0
0
0

0
650,000
0
5,000
0
200,000
0
0
0
0
0
0
0
0
0
200,000

0
50,000
0
B1-General Requirements

Bills of Quantities and Dayworks

B1/16

Jabal Al-Ka'aba Hotel


1,500,000

0
250,000

0
200,000

0
150,000
0
600,000

0
250,000

0
0
0
0
0
150,000
0
100,000
0
50,000
0
250,000
0
250,000
0
300,000
0
200,000

B1-General Requirements

Bills of Quantities and Dayworks

B1/17

Jabal Al-Ka'aba Hotel


100,000

0
250,000

0
0
0
0
0
0
50,000

0
0
0
0
0
0
100,000
0
0
500,000
0
200,000
0
150,000
0
0
200,000

0
0
0
0
0
250,000

B1-General Requirements

Bills of Quantities and Dayworks

B1/18

Jabal Al-Ka'aba Hotel

37,051,500

Amount : SAR

B1-General Requirements

Bills of Quantities and Dayworks

B1/19

Jabal Al-Ka'aba Hotel

B1-General Requirements

Bills of Quantities and Dayworks

B1/20

Jabal Al-Ka'aba Hotel


Item

Item Description

Quantity

Unit

Rate

Item

100,000

Amount : SAR

SITE WORK
Site clearance
A

Allow for site clearance including removal of any


unsuitable material and obstructions.

Shoring
B

0
0

The Contractor shall be responsible for the design,


supplying, execution and maintenance for the shoring
system as per drawings and specification and local
authorities requirements. Further, the rate shall include
supply and install of any additional shoring
requirements considering the conditions of site works.
It is the Contractor's responsibility to carry out the
works for satisfactory completion in accordance with
applicable specification and local authorities
requirements all complete to the approval of the
Engineer.

Item 2,000,000

2,000,000
0
0
0

1 Item 2,000,000

2,000,000
0
00

Dewatering
C

The Contractor shall design, furnishing, installing,


testing and maintaining the dewatering system to
control ground water and surface water as required to
comply with the specification and local authorities
requirements, including water discharge to location
approval by authorities, price to include all
commissioning, maintenance and decommissioning to
the required period and to the Engineer approval.
Excavation

Excavation for foundation from existing zero level to


the required level and to the Engineer approval.
8,099

m3

250

2,024,750
0
0
0

8,099

m3

50

404,950
0
0
0
0
0
0
0

Disposal
E

100,000

Disposal of surplus excavated material from the site to


the approved location as directed by the Engineer and
local authorities.

SITE WORK (Cont'd)


Filling

B2 - Site Work

Bills of Quantities and Dayworks

B2/21

Allow for approved compacted filler (200mm thick


each layer) laid below foundation (if find Jabal
underAl-Ka'aba
any
Hotel
part of foundation that rock is very weak it must be
excavated, removed and filled with plain concrete) to
specification and soil investigation report.
1
Item

300,000

300,000
0
0
0

50

71,040
0

Top Soil Compaction


B

Allow for all necessary compaction, to top of


excavation below foundation, complete as per
specification.

1,421

m2

Anti-Termite Treatment
C

0
0

Allow for anti-termite treatment complete in


accordance with specifications and drawings. The
product should be registered with the Ministry of
Agriculture. The total quantity of chemical required for
testing should be reserved in advance at the site as per
the total area. The subcontractor should be operational
in this market for a minimum period of ten (10) years.
Certificate from the supplier confirming that the
product is non-hazardous to humans and environment.

Item

100,000

100,000
0
0
0

1,660

m3

100

166,000
0
0
0
0
0
0

Back Filling
D

Allow for approved compacted back filling material


laid ,in layers 250 mm thick maximum ,above raft up to
bottom of slab on grade to specification and soil
investigation report and to the Engineer's approval..

SITE WORK (Cont'd)


Additional Items
A

The Tenderer is requested to identify and list separately


in details and price any items of work not listed above
but shown in the drawings or mentioned in the
specification or required for satisfactory completion of
the work, any items not listed below shall be deemed to
be included.

1 Item

SITE WORK

Amount : SAR

Collection
Page B2/1
Page B2/2
Page B2/3
7,166,740

Total of Bill No. 2 - SITE WORK


To The Grand Summary
B2 - Site Work

SAR
Bills of Quantities and Dayworks

7,166,740
B2/22

Jabal Al-Ka'aba Hotel

B2 - Site Work

Bills of Quantities and Dayworks

B2/23

Jabal Al-Ka'aba Hotel


Item

Item Description

Quantity Unit

Rate

Amount : SAR

500

71,000
0

CONCRETE WORK
Sub-structure concrete
Plain Concrete
Plain concrete , in accordance with concrete
specification and mix design complete as shown on
drawings and as specified.
A

100mm thick under raft and tie beams.

142

m3

Reinforced Concrete

Reinforced concrete , in accordance with concrete


specification and mix design complete as shown on
drawings and as specified (reinforcement and
formwork measured separately).
B

Raft

0
0
2,486

m3

500

Columns

116

m3

700

Core walls.

49

m3

750

Shear walls

210

m3

750

Tie beams

m3

750

100mm/250mm thick solid slab

213

m3

700

Slab on grade

78

m3

500

Water tank walls and base slabs

510

m3

600

Steel Bar Reinforcement


Deformed high tensile steel bar reinforcement with
yield strength of 460 N/mm2 in accordance with
BS4483 and as specified, Qatar steel.

1,243,000
0
81,200
0
36,750
0
157,500
0
750
0
149,100
0
38,750
0
306,000
0
0

215,000

kg

5.00

To columns

7,212

kg

5.00

To core walls.

20,309

kg

5.00

To shear walls

39,035

kg

5.00

0
0
1,075,000
0
36,060
0
101,545
0
195,175
0

To tie beams

688

kg

5.00

3,440

To 100mm/250mm thick solid slab

42,300

Kg

5.00

To slab on grade.

5,500

Kg

5.00

To water tank wall and base slab.

120,000

kg

5.00

211,500
0
27,500
0
600,000
0
0

To raft

To Collection
B3 - Concrete Work

Bills of Quantities and Dayworks

B3/24

Jabal Al-Ka'aba Hotel

Formwork
A

To Raft

270

m2

200

To columns

108

m2

400

To core walls.

376

m2

400

To shear walls

462

m2

400

To tie beams

m2

400

To 100mm/250mm thick solid slab

950

m2

300

To slab on grade

39

m2

200

To water tank walls and slabs.

2,533

m2

400

Item

300,000

Item

200,000

Sundries
I

Allow for control construction and contraction joints


and the like as required all in accordance with the
drawings and specification.
Allow for filler materials of slab on grade.

Super-structure
Reinforced Concrete
Reinforced concrete , in accordance with concrete
specification and mix design complete as shown on
drawings and as specified (reinforcement and
formwork measured separately).
A

Columns.

2,125

m3

1,200

Core walls.

1,014

m3

1,200

Shear walls

441

m3

1,200

230mm thick post tension slabs.

10,723

m2

300

250mm thick post tension slabs.

12,368

m2

320

275mm thick post tension slabs.

976

m2

800

Ramp Slab

133

m3

800

200mm thick solid slab.

11

m3

800

Beams & PT Beams

80

m3

1,000

Stair cases steps, landing.

267

m3

1,000

Parapet, planters and decorative sections.

180

m3

1,200

B3 - Concrete Work

Bills of Quantities and Dayworks

150,400
0
184,800
0
3,300
0
285,000
0
7,700
0
1,013,200
0
0
0

CONCRETE WORK (Cont'd)

Steel Bar Reinforcement

0
0
0
0
54,000
0
43,200
0

300,000
0
200,000
0
0
0
0
0
0
0
0

0
0
2,550,000
0
1,216,800
0
529,560
0
3,216,900
0
3,957,760
0
780,800
0
106,400
0
8,800
0
80,000
0
267,000
0
216,000
0
0
0

B3/25

Deformed high tensile steel bar reinforcement with


yield strength of 460 N/mm2 in accordance
with
Jabal Al-Ka'aba
Hotel
BS4483 and as specified, Qatar steel.
L

Columns

22,340

kg

5.00

Core walls

176,109

kg

5.00

Shear walls

142,660

kg

5.00

Solid slab and Ramp.

17,252

kg

5.00

Post tension slabs.

282,980

kg

5.00

0
111,700
0
880,545
0
713,300
0
86,260
0
1,414,899

Beams & PT Beams

13,128

kg

5.00

65,640

Stair cases steps, landing.

85,440

kg

5.00

Parapet, planters and decorative sections.

19,200

kg

5.00

427,200
0
96,000

CONCRETE WORK (Cont'd)


Superstructure (Cont'd)
Post Tension slabs
A

Post Tension specialist design.

24,067

m2

300

7,220,100
0
7,220,100
0
0
0
0
282,600
0
3,923,500
0
1,623,600
0
9,342,200
0
390,600
0
709,200
0
600,000

Steel strands cable , complete casting , tendon duct


.,etc.
Formwork

24,067

m2

300

Sides of columns

471

m2

600

Sides of core wall.

7,847

m2

500

Sides of shear wall

2,706

m2

600

Sides and soffits of solid and post tension slabs and Ram 26,692

m2

350

Sides and soffits of beams & PT Beams

651

m2

600

Stair cases steps, landing.

1,182

m2

600

Parapet, planters and decorative sections.

1,000

m2

600

Allow for control construction and contraction joints or


the like as required all in accordance with the drawings
and specification.

Item

700,000

Allow for light weight concrete filling as per drawings.

Item

350,000

Allow for precast cover to top of shafts.

Item

300,000

Allow for Sub Station Concrete work including


concrete, steel and formwork all complete to the
Engineer approval.
Allow for planter edge ,steps.. including concrete, steel
and formwork all complete to the Engineer approval.

Item

350,000

350,000
0

Item

150,000

150,000

Sundries
J

B3 - Concrete Work

Bills of Quantities and Dayworks

700,000
0
350,000
0
300,000
0

B3/26

CONCRETE WORK (Cont'd)

Jabal Al-Ka'aba Hotel

Superstructure (Cont'd)
Wheel stopper
A

Precast concrete wheel stoppers, hydraulically pressed


to floors, bedded in epoxy resin mortar and fixed to
slab with 16mm dia anchor bolt 2 nos each finished
with epoxy paint.

Item

200,000

Item

500,000

500,000

1 Item

250,000

250,000

Civil works in connection with MEP installations


B

Allow for all necessary builder's work ,inertia bases


under MEP equipments and pumps and associated
works complete as shown on MEP drawings, general
notes on drawings, preambles and specifications.

200,000
0
0
0

Civil works in connection with Manholes


C

Allow for all necessary excavation , filling , pcc, solid


block and bituminous water proofing paint all complete
as shown on drawings, and specifications, covers
(measured separately).
Additional Items

The Tenderer is requested to identify and list separately


in details and price any items of work not listed above
but shown in the drawings or mentioned in the
specification or required for satisfactory completion of
the work , any items not listed below shall be deemed to
be included.

Item

CONCRETE WORK
Amount : SAR

Collection
Page B3/1
Page B3/2
Page B3/3
Page B3/4
Page B3/5

Total of Bill No. 3 - CONCRETE WORK


To The Grand Summary
B3 - Concrete Work

Bills of Quantities and Dayworks

57,413,334

SAR
B3/27

Jabal Al-Ka'aba Hotel

B3 - Concrete Work

Bills of Quantities and Dayworks

B3/28

Jabal Al-Ka'aba Hotel


Item

Item Description

Quantity

Unit

Rate

Amount : SAR

MASONRY
Light weight AAC Block
Supply & fix light weight AAC block bedded and
jointed as manufacture, tied to concrete columns and
beams with galvanized steel anchor as per specification.
A

100mm thick internally

7,708

m2

70

539,560
0

150mm thick internally

35

m2

85

2,975
0

200mm thick internally

13,606

m2

100

1,360,600
0

250mm thick internally

m2

120

720
0

300mm thick internally

637

m2

164

104,468
0

100mm thick externally

7,504

m2

120

900,480
0
0

Solid Block

0
0

Supply & fix Solid Block bedded and jointed in cement


sand mortar ( 1:3 ).
G

200mm thick solid block.

0
0

824

m2

150

123,600
0
0
0

Lintels
Allow for precast reinforced concrete lintels including
all bearing blocks isolation paper, metal supports, etc.

0
0

100 x 200mm.

1,678

30

200 x 200mm.

753

60

300 x 200mm.

135

90

B4 - Masonry

Bills of Quantities and Dayworks

50,340
0
45,180
0
12,150

B4/29

MASONRY (Cont'd)

Jabal Al-Ka'aba Hotel

Additional Items
A

The Tenderer is requested to identify and list separately


in details and price any items of work not listed above
but shown in the drawings or mentioned in the
specification or required for satisfactory completion of
the work , any items not listed below shall be deemed to
be included.

Item

MASONRY WORKS
Collection

Amount : SAR

Page B2/1

3,140,073
Page B2/2

Total of Bill No. 4 - MASONRY


To The Grand Summary

B4 - Masonry

Bills of Quantities and Dayworks

SAR

B4/30

Jabal Al-Ka'aba Hotel


Item

Item Description

Quantity Unit

Rate

Amount : SAR

METAL WORK
Aluminum Handrail & Balustrade
Supply & fix poder coated aluminum handrail &
balustrade as per drawings and specifications and to
the engineer's approval.
A

Staircase 1 (from P1 to Lower Roof)

80

1,000

Staircase 2

101

1,000

Staircase 3

101

1,000

80,000
0
101,000
0
101,000
0

Stainless Steel Handrail and Tempered glass


Balustrade(Staircase 1)
D

Supply & fix stainless steel handrail and and tempered


glass balustrade as per drawings, for Engineer's
approval.
Chequered plate covers
Supply & fix galvanized steel chequered plate
minimum (8+2mm) thick including 8mm square bar
welded to 50*50*5mm steel angel at perimeter with all
supports, epoxy paint cast into concrete with tang bars
to EWA approval, to electrical platform.

0
0
17

1,500

25,5000
0
0

Item

250,000

250,0000
00

Item 1,000,000

Access platform
F

Supply & fix access platforms for shaft, consisting of


heavy galvanized steel expanded mesh supported on
angel or T- sections clipped to plate and supported on Ibeam built into the structure, including paint all
complete.
Cat -ladder
Supply & fix aluminum powder coated cat ladder with
aluminum safety cage hoop comprising of aluminum
flat side stringers minimum 89*28 mm box section,
25mm dia aluminum rungs, fixed to concrete wall.

For roof.

Item

15,000

For inaccessible shafts.

Item

30,000

METAL WORK (Cont'd)

1,000,000
0
0
0
0
0
0
0
0
0
15,000
0
30,000
0
0
00

Ladder

00

Supply & fix aluminum ladder with all necessary


support, fixing, complete as on drawings to the
Engineer approval.

B5 - Metal Work

Bills of Quantities and Dayworks

B5/31

For water tank.

For lift pit, lift machine room

Item

25,494

Item

20,000

20,0000
00

Item

25,000

25,0000
0
0

Item

100,000

100,000
0
00

Item

Jabal Al-Ka'aba Hotel


1

Stainless steel access cover & ladder


C
D

Supply & fix access cover and ladder for the water
tanks, all complete as per drawings for Engineer
approval.
Canopy
Supply & fix stainless steel mirror finished grade 316
canopy including accessories, bolts, fixing elements all
complete as drawings, for Engineer's approval.

Additional Items
E

The Tenderer is requested to identify and list separately


in details and price any items of work not listed above
but shown in the drawings or mentioned in the
specification or required for satisfactory completion of
the work, any items not listed below shall be deemed to
be included.

0
25,4940

METAL WORK
Amount : SAR

Collection
Page B5/1

1,772,994

Page B5/2
Total of Bill No. 5 - METAL WORK
To The Grand Summary

B5 - Metal Work

Bills of Quantities and Dayworks

SAR

B5/32

Jabal Al-Ka'aba Hotel


Item

Item Description

Quantity

Unit

Rate

20

Amount : SAR

THERMAL & MOISTURE PROTECTION


Sub Structure Waterproofing
A

1000 gauge polythene sheet under plain concrete blindin

1,686

m2

Supply & apply 2 coats bituminous paint to receive


membrane.

5,663

m2

33,712
0

20

113,260
0

Supply & apply two layers 5mm SBS waterproofing


membrane torch applied for substructure concrete
foundation, neck columns/walls & exernal walls of
water tanks .

0
0

To Horizontal surface.

3,354

m2

80

268,320
0

To Vertical surface.

2,310

m2

100

231,000
0

Supply & apply protection board one layer 6mm thick


to be added to the vertical membrane system.

2,310

m2

Supply & apply 50 mm screed to be added above the


horizontal membrane system over one layer 1000 gauge
polythene sheet.

3,354

item

60

138,600
0

40
2

134,160
0
0
0

Water Stopper
G

Supply & fix PVC water stopper, to water tank,


retaining wall all complete to the Engineer approval.

40,000

40,000
0

Water tank
H

0
0

Supply & apply waterproofing system for internal


surfaces of water tank as per specification.

2,900

m2

100

290,000
00
0

Planters
I

00

Supply & apply waterproofing system for internal


surfaces of planters box as per specification.

43

m2

70

2,975
0
0
0

THERMAL & MOISTURE PROTECTION (Cont'd)

Roof & upper roof water proofing

0
0

Supply & install the following ;

0
0

Light weight concrete laid to slope, minimum 50mm


thick smoothly finished to receive waterproofing
membrane as shown on drawings and as specified.

B6 - Thermal. Mois. Protection

Bills of Quantities and Dayworks

70

763

53,410
0

B6/33

One layer 4mm APP waterproofing membrane torch


applied with primer, including the Jabal
same to
the corners,
Al-Ka'aba
Hotel
pipe penetration .etc.

60

763

m2

50mm thick extruded polystyrene board insulation with


lap joint.

763

m2

Slip sheet, 100g/m2 non woven synthetic geotextile, loose


laid over the polystyrene insulation with 200mm laps at
joints as specified.

763

Flexible woven polypropylene fabric 0.5mm thick


protection board.

763

m2

50mm thick layer of rounded Wadi gravel, upper roof.

763

m2

Cement and sand fillet to the perimeter corner, around


pipe penetration . etc.

312

Mastic sealant between parapet wall, pipe


penetration etc. and metal flashing as specified.

312

Aluminum pressure plate flashing as specified.

312

500*500*50mm thick precast concrete paving tiles loose


laid on sand layer and including PVC adjustable rings,
including skirting.

763

Item

C
D

Waterproofing to rain water outlets.

45,780
0
60

45,780
0

60
2

45,780
0
40

30,520
0

20

15,260
0

25

7,800
0

40

12,480
0

100

31,200
0

100
2

76,300
0
10,000

10,000
0
0
0
0

THERMAL & MOISTURE PROTECTION (Cont'd)


Terraces waterproofing

0
0

Supply & install the following ;

0
0

Light weight concrete laid to slope, minimum 50mm


thick smoothly finished to receive waterproofing
membrane.

253

m2

One layer 4mm thick APP modified bitumen


waterproofing membrane torch applied including
primer, including the same to the corners.

253

Extruded polystyrene board insulation, 50mm thick


with overlap joint.

253

m2

Slip sheet 100g/m2 non woven synthetic geotextile.

253

m2

60

15,180
0

Cement and sand fillet to the perimeter corner.

109

25

2,725
0

Mastic sealant between parapet wall and metal flashing


as specified.

109

Aluminum pressure plate flashing as specified.

109

B6 - Thermal. Mois. Protection

Bills of Quantities and Dayworks

70
17,710
0
60
2

15,180
0
60

15,180
0

40

4,360
0

100

10,900
0
B6/34

Wet areas waterproofing

0
0

Jabal
Al-Ka'aba
for kitchen/ restaurant/ baths/ toilets/
linens/
laundry/Hotel
ablution/ veg. wash /shaft/ pump/ garbageetc.
H

Supply & install liquid applied water proofing system


including 25mm screed over one layer 1000 gauge
polythene sheet.

0
0
75

4,207

Ditto, but perimeter of the wet areas, including


protection board.

m2

315,525
0

0
0
0

THERMAL & MOISTURE PROTECTION (Cont'd)

0
0

Anti fungus sealant


A

0
0

Supply & apply anti fungus sealant above false ceiling


of wet areas.

15,552

m2

100

1,555,200
0
0

Fire stopping
B

0
0

Allow for fire resisting foam/ sealant for closing


opening/ sealers for services and any other places as per
requirements of civil defense and other concern
authority.
Additional Items
The Tenderer is requested to identify and list separately
in details and price any items of work not listed above
but shown in the drawings or mentioned in the
specification or required for satisfactory completion of
the work, any items not listed below shall be deemed to
be included.

500,000

Item

500,000
0
0
0

Item

THERMAL & MOISTURE PROTECTION


Collection

Amount : SAR

Page B6/1

4,078,297
Page B6/2

Page B6/3

Page B6/4
Total of Bill No. 6 - THERMAL & MOISTURE PROTECTION
To The Grand Summary

B6 - Thermal. Mois. Protection

Bills of Quantities and Dayworks

SAR

B6/35

Jabal Al-Ka'aba Hotel


Item

Item Description

Quantity

Unit

Rate

Amount : SAR

DOORS & WINDOWS


The following works, glazed curtain walls, glazed panels,
aluminum doors, windows, timber doors, coating system all
by specialist sub contractor, including glass, glazing
accessories, spandrel units, insulation, rigid rock wool
insulation, ironmongery/ hardware, fire stops, angels, joints,
sealants, sub frames, cover plates and fittings including all
associated works complete as detailed on drawings,
specification to the Engineer approval.
All external aluminum sections to be thermally insulated as
per requirements of municipality.
Curtain walls
Supply & fix curtain walls double & single glazed 4 sided
structural glazing including hardware, accessories ...etc all
complete as per drawings and specifications and to the
Engineer's approval (aluminum sections to be super durable
powder coated).
A

Type -CW1.

No

520,000

520,0000
445,0000

Type -CW2.

No

445,000

Type -CW3.

No

80,000

Type -CW4.

No

70,000

80,0000
70,0000

Type -CW5.

No

Type -CW6.

No

35,000
31,000
31,000

35,0000
31,0000

Type -CW7.

No

50,000

Type -CW8.

No

45,000

50,0000
45,0000

Type -CW9.

11

No

40,000

Type -CW10.

23

No

25,000

Type -CW11.

13

No

20,000

440,0000
575,0000
260,0000
0

DOORS & WINDOWS (Cont'd)

0
0
00

Aluminum Doors, Windows


Supply & fix double glazed doors, windows with aluminum
frame including hardware, accessories.. Etc. all complete as
per drawings and specifications and to the Engineer's
approval. (super durable powder coated).

00

Type DA5, size 1500*2100 mm. (with automatic sliding door)


A
B

Type DA12, size 2000*2100 mm.

B7 - Doors Windows

Bills of Quantities and Dayworks

No

No

10,000

60,0000
25,2000

6,300
B7/36

Type WA1, size 2200*2200 mm.

205

No

7,500

Jabal Al-Ka'aba Hotel 218

No

3,000

1,537,5000
654,0000

Type WA2, size 900*2200 mm.

Type WA3, size 1500*2200 mm.

19

No

4,000

76,0000

Type WA4, size 7200*7150 mm (with automatic revolving


door)

1
1

No
No

No

20,000

75,000

75,0000
18,0000

18,000

G
H

Type WA5, size 6540*2300 mm.


Type WA6, size 7200*2300 mm.

Type WA7, size 2200*2200 mm.

16

No

6,000

Type WA8, size 1500*1100 mm.

No

2,000

Type WA9, size 3500*2000 mm.

No

8,500

20,0000
96,0000
12,0000
17,0000
0
0

Supply & fix 10mm thick clear heat tempered glass window
with aluminum frame including hardware, accessories.. Etc.
all complete as per drawings and specifications and to the
Engineer's approval. (super durable powder coated).
L

Type WA10, size 2200*2200 mm.

No

0
0
0
72,0000
0
0

8,000

Supply & fix 12mm thick frameless monolithic clear glass


door including hardware, accessories etc.... all complete as
per drawings and specifications and to the Engineer's
approval.

0
0
0

Type FGC1, size 1900*2300 mm.

No

7,000

Type FGC2, size 1950*2300 mm.

No

7,000

Type FGC3, size 1800*2300 mm.

No

6,500

7,0000
7,0000
13,000
0
0
0
0
0

DOORS & WINDOWS (Cont'd)


Aluminum Louver Doors

0
0

Supply & fix heavy gauge powder coated aluminum louver


doors with powder coated aluminum frame with PVC fly
mesh backing to internal face in aluminum frame including
hardware, accessoriesm.. etc all complete as per drawings
and specifications and to the Engineer's approval (super
durable powder coated).
A

Type -LA1, 3050 x 3250mm high.

No

12,000

Type -LA2, 3900 x 2650mm high.

No

12,500

Type -LA3, 3700 x 2650mm high.

No

12,000

Type -LA4, 1500 x 9200mm high.

No

17,000

Type -LA5, 2200 x 9200mm high.

No

24,500

Type -LA6, 900 x 9200mm high.

No

10,000

Type -LA7, 2300 x 9200mm high.

No

25,500

B7 - Doors Windows

Bills of Quantities and Dayworks

0
0
36,000
0
12,500
0
12,000
0
136,000
0
73,500
0
10,000
0
25,500
0
B7/37

Type -LA8, 3000 x 2100mm high.

Jabal Al-Ka'aba Hotel

No

8,000

No

11,500

Type -LA9, 1800 x 5200mm high.

Type -LA10, 1500 x 2100mm high.

No

4,000

Type -LA11, 2500 x 2400mm high.

No

7,500

Type -LA12, 5950 x 10950mm high.

No

80,000

DOORS & WINDOWS (Cont'd)


Sandwich Panel Doors

16,000
0
11,500
0
4,000
0
7,500
0
320,000
0
0
0
0
0
0

Supply & fix double skin aluminum sheet in aluminum


frame (super durable powder coated) with minimum 40mm
thick insulation in fill including hardware, accessories... etc
all complete as per drawings and specifications and to the
Engineer's approval (aluminum sections to be super durable
powder coated).
A

Type DA1, 1000 x 2100mm high.

No

3,200

Type DA2, 6800 x 2100mm high.

10

No

21,500

Type DA3, 1000 x 2100mm high.

No

3,200

Type DA4, 1600 x 2100mm high.

No

5,200

Type DA6, 1000 x 2100mm high.

No

3,200

Type DA7, 1600 x 2100mm high.

No

5,200

Type DA8, 1500 x 2100mm high.

No

4,800

Type DA9, 1800 x 2100mm high.

No

6,000

Type DA10, 1100 x 2100mm high.

No

4,000

Type DA11, 1100 x 2100mm high.

21

No

4,000

Type DA13, 1100 x 2100mm high.

No

4,000

No

200,000

Steel Door
Supply & fix steel door including hardware, accessories ...etc
all complete as per drawings and specifications and to the
Engineer's approval (PC rate for supply SAR 150,000.00)
L

DS1
Third Party Assurance Test for all Aluminum Works

Allow for third party assurance and testing as specified.

Item 250,000

Allow for all testing as specified.

Item 150,000

DOORS & WINDOWS (Cont'd)


Timber Doors
B7 - Doors Windows

Bills of Quantities and Dayworks

0
0
19,200
0
215,000
0
3,200
0
26,000
0
12,800
0
10,400
0
4,800
0
36,000
0
20,000
0
84,000
0
4,000
0
0
0
0
0
0
0
0
0
200,000
0
0
0
250,000
0
150,000
0
0
0
0
0
0
0
B7/38

Supply & fix timber doors as per drawings, specification


and to the Engineer approval, including
acoustic
insulation,
Jabal
Al-Ka'aba
Hotel
ironmongery (fix only).

0
0

For Fire Rated doors follow the latest civil defense


requirements, to the Engineer approval.

0
0
484,5000

Type DT1, 1000 x 2100mm high, to flats

285

No

1,700

Type DT2, 1100 x 2100mm high, to staircase

84

No

1,900

Type DT3, 1100 x 2100mm high, to staircase


Type DT4, 1000 x 2100mm high, to bedrooms
Type DT5, 900 x 2100mm high, to kitchen & store

No
No

1,900

D
E

4
84
6

No

1,550

Type DT6, 800 x 2100mm high, to bathroom

408

No

1,450

9,3000
591,6000

Type DT7, 1500 x 2100mm hig, service lift lobby & corr.

H
I

Type DT8, 1000 x 1600mm high, to elec/tel/house keeping


Type DT9, 1500 x 2100mm high, to majlis/dining/sh. Office

34
60

No
No

2,600
1,300

88,4000
78,0000

No

3,000

Type DT10, 1600 x 2100mm high, to men prayer/ rest.


Type DT11, 1800 x 2100mm high, to men/ women prayer
Type DT12, 800 x 2100mm high, to w.c.

No
No

2,400

K
L

3
4

15,0000
7,2000
12,4000

29

No

1,450

Type DT13, 1000 x 2100mm high, to toilet/ HC toilet


Type DT14, 1000 x 2100mm high, to offices/ restaurant
Type DT15, 1100 x 2100mm high, flat/ office entrance

No
No

1,700

N
O

11
10
5

No

1,900

Ite
m

500,000

1,700

159,6000
7,6000
142,8000

3,100

42,0500
18,7000
17,0000

1,700

9,5000
0
0
0
0

Sundries
P

Allow for sub-frame for timber doors 1.8mm marenti


plywood.
DOORS & WINDOWS (Cont'd)

Additional Items
A

The Tenderer is requested to identify and list separately in


details and price any items of work not listed above but
shown in the drawings or mentioned in the specification or
required for satisfactory completion of the work, any items
not listed below shall be deemed to be included.

Item

500,000
0
0
0
0
0
0
0

DOORS & WINDOWS


Collection

Amount : SAR

Page B7/1

9,124,250
B7 - Doors Windows

Bills of Quantities and Dayworks

B7/39

Page B7/2

Jabal Al-Ka'aba Hotel


Page B7/3

Page B7/4

Page B7/5

Page B7/6
Total of Bill No. 7 - DOORS & WINDOWS
To The Grand Summary

B7 - Doors Windows

SAR

Bills of Quantities and Dayworks

B7/40

Jabal Al-Ka'aba Hotel


Item

Quantity Unit

Item Description

Rate

Amount : SAR

FINISHES
Internal Flooring
Terrazzo tiles (to receive Carpet)
A

Supply & fix terrazzo tiles 300*300*25mm, including


cement sand mortar (1:3) jointing and pointing with
approved grout as drawings and to the Engineer
approval, to be 10mm below finish level.

11,606

m2

55

638,330
0
0
0

379

m2

600

227,400
0
0
0

778

m2

500

389,000
0
0
0

271

m2

110

29,810
0

1,670

m2

110

183,700
0

292

m2

110

32,120
0
0
0
0

Granite tiles
B

Supply & fix granite tiles including cement sand mortar


(1:3) jointing and pointing with approved grout as per
drawings and to the Engineer's approval. (PC rate SAR
500.00/m2)
Marble tiles

Supply & fix mable tiles including cement sand mortar


(1:3) jointing and pointing with approved grout as per
drawings and to the Engineer's approval. (PC rate SAR
400.00/m2)
Non-slip Graniti Ceramic tiles

Supply & fix non-slip graniti ceramic tiles, including


cement sand mortar (1:3) jointing and pointing with
approved grout as per drawings and to the Engineer's
approval. (PC rate SAR 60.00/m2)
Supply & fix non-slip graniti ceramic tiles, including
cement sand mortar (1:3) jointing and pointing with
approved grout as per drawings and to the Engineer's
approval. (PC rate SAR 60.00/m2)
Supply & fix non-slip graniti ceramic tiles, including
cement sand mortar (1:3) jointing and pointing with
approved grout as per drawings and to the Engineer's
approval. (PC rate SAR 60.00/m2)

FINISHES (Cont'd)
Internal Flooring (Cont'd)

0
0
0

Non-slip Ceranic tiles

B8 - Finishes

Bills of Quantities and Dayworks

B8/41

Supply & fix non-slip Ceramic Tiles, including cement


sand mortar (1:3) jointing and pointing
withAl-Ka'aba
approved Hotel
Jabal
grout as per drawings and to the Engineer's approval.
(PC rate SAR 30.00/m2)
830
Supply & fix non-slip Ceramic Tiles, including cement
sand mortar (1:3) jointing and pointing with approved
grout as per drawings and to the Engineer's approval.
(PC rate SAR 40.00/m2)
Supply & fix non-slip Ceramic Tiles, including cement
sand mortar (1:3) jointing and pointing with approved
grout as per drawings and to the Engineer's approval.
(PC rate SAR 40.00/m2)

m2

110

91,300
0

2,252

m2

110

247,720
0

253

m2

11,044

m2

250

2,761,000
0

562

m2

200

112,400
0
0
0
0
0
0
0
0

110

27,830
0
0
0

Carpet Flooring over terrazo tiles


D

Supply & fix Carpet Flooring over Terrazo Tiles as per


drawings and to the Engineer's approval. (PC rate for
Carpet SAR 250.00/m2)
Supply & fix Carpet Flooring over Terrazo Tiles as per
drawings and to the Engineer's approval. (PC rate for
Carpet SAR 150.00/m2)

FINISHES (Cont'd)
Internal Flooring (Cont'd)
Granite Tile for Staircase 1

Supply & fix Granite tiles for Staircase 1 at Ground &


Mezzanine Floor, including cement sand mortar (1:3)
jointing and pointing with approved grout as per
drawings and to the Engineer's approval. (PC supply
rate SAR 500/m2)

0
0

30mm thick for treads (with two non slip carborandum


grooves, chamfered edge)

62

400

20mm thick for riser

62

400

ditto, 30mm thick for landings

m2

600

24,800
0
24,800
0
3,000
0

Terrazo Tile for Staircases 2 & 3

0
0

Supply & fix Terrazo tiles, including cement sand


mortar (1:3) jointing and pointing with approved grout
as per drawings and to the Engineer's approval.
D
E

0
0

for treads (with two non slip carborandum grooves,


chamfered edge)

3,335

80

266,800
0

for riser

3,335

60

200,100
0

B8 - Finishes

Bills of Quantities and Dayworks

B8/42

for Landings.

404

m2

2,493

m2

Jabal Al-Ka'aba Hotel

100

40,400
0
0
0

Flooring for parking, driveways and ramps


G

Supply & apply 100% solids epoxy, flexible epoxy wear


coat system seeded into epoxy with manufacturer
approved aggregate, having a minimum hardness of six
on the Moh scale, at the recommended coverage, the
system should have A-1 fire rating ASTM E86, including
100mm skirting and all associated works. Top coat to be
Polyurethane for UV resistant. Rough surface for
ramps.
120

FINISHES (Cont'd)

299,160
0
0
0
0
0
0

Cement screed & epoxy paint


A
B

Supply & apply 50mm smooth cement screed + epoxy


resin based paint as per drawings and engineer's
approval.
Supply & fix Galvanized Expanded Mesh Plaform as
per drawings and engineer's approval.

123

m2

120

14,760
0

13

m2

2,000

26,000
0
0
0

123

250

30,750
0

Supply & fix 100mm high Timber skirting (PC supply


rate SAR 60/M)

7,104

100

710,400
0

Supply & fix 100mm high Ceramic skirting to match


flooring, including cement sand mortar (1:3).

4,112

40

1,316

30

164,480
0
39,480
0
0
0

Skirting
C
D
E
F

Supply & fix 100mm high Graniti skirting to match


flooring, including cement sand mortar (1:3).

Supply & fix 100mm high Terrazo skirting to match


flooring.
Threshold
Supply & fix approved first grade granite threshold
with rubber seal, 25mm thick bedded on and including
cement sand mortar (1:3) sealing backs and sides with
approved sealant / coating, polishing and cleaning upon
completion, with exposed pencil rounded set 15mm
above finished floor level, to the Engineer approval (P C
supply rate SAR 400/m2)

100mm width

366

250

200mm width

528

250

300mm width

98

250

FINISHES (Cont'd)
Ablution Sitting

B8 - Finishes

Bills of Quantities and Dayworks

0
0
91,500
0
132,000
0
24,500
0
0
0
0
0

B8/43

Supply & fix 40x40cm marble sitting in ablutions


including cement sand mortar (1:3) jointing
and
Jabal Al-Ka'aba
Hotel
pointing with approved grount, all complete to the
engineer's approval. (PC rate SAR 250/m2)
55

no.

2,500

137,500
0

Plaster Works

0
0

Supply & apply cement sand plaster to concrete and


block surfaces including all beads, angles, grooves as
required and specified /Note: plaster work not required
to soffit of slabs above false ceiling.
Internal wall
B

15mm thick, to receive paint finish.

44,311

m2

40

47

m2

50

Internal ceiling
C

10mm thick, to receive paint finish.


O.T.S and Shafts

15mm thick, to o.t.s wall.

1,988

m2

70

221

m2

150

m2

200

External Wall
E

20mm thick, to receive paint finish.


External Ceiling

10mm thick, to receive paint finish.


FINISHES (Cont'd)
Internal Walls (Cont'n)
Internal Walls:

0
0
0
0
1,772,440
0
0
0
2,350
0
0
0
0
139,160
0
0
0
33,150
0
0
0
1,600
0
0
0
0
0
0
0
0

Granite tiles
A

0
0

Supply & fix (dry fix) Granite Tiles including plaster


backing, tile adhesives grouting, jointing and pointing,
plastic corner beads as per drawings and to the
Engineer's approval, (PC Rate 500 SAR/ m2).

383

m2

650

248,950
0
0
0

6,382

m2

450

2,871,900
0
0
0

Marble tiles
B

Supply & fix Marble Tiles including plaster backing, tile


adhesives grouting, jointing and pointing, plastic corner
beads as per drawings and to the Engineer's approval,
(PC Rate 400 SAR/ m2).
Graniti Ceramic tiles

B8 - Finishes

Bills of Quantities and Dayworks

B8/44

Supply & fix Graniti Ceramic Tiles including plaster


backing, tile adhesives grouting, jointing
andAl-Ka'aba
pointing, Hotel
Jabal
plastic corner beads as per drawings and to the
Engineer's approval, (PC Rate 60 SAR/ m2).
8,788

m2

130

1,142,440
0
0
0

353

m2

130

45,890
0

1,165

m2

130

151,450
0
0
0
0

Glazed Ceramic tiles


D

Supply & fix Glazed Ceramic Tiles including plaster


backing, tile adhesives grouting, jointing and pointing,
plastic corner beads as per drawings and to the
Engineer's approval, (PC Rate 30 SAR/ m2).
Supply & fix Glazed Ceramic Tiles including plaster
backing, tile adhesives grouting, jointing and pointing,
plastic corner beads as per drawings and to the
Engineer's approval, (PC Rate 40 SAR/ m2).

FINISHES (Cont'd)
Painted walls
A
B
C
D

0
0

Supply & apply Stucco Paint over smooth finish cement


plaster.

19,737

m2

50

986,850
0

Supply & apply Synthetic Enamel Paint over smooth


finish cement plaster.

2,581

m2

35

90,335
0

10,062

m2

35

352,170
0

11,931

m2

100

1,193,100
0
0
0
0

m2
m2

150

Ditto, but for High Level

7,277
6,679

200

1,091,550
0
1,335,800
0

Supply and fix 600 x 600mm decorative gypsum fiber


acoustic tiles false ceiling with suspension system as per
drawings all complete to the Engineer's approval, including
emulsion paint.

1,112

m2

100

111,2000

303

m2

120

36,360
0

22

m2

150

3,300
0

Supply & apply Washable Emulsion Paint over smooth


finish cement plaster.
Supply & apply anti-carbonation coat on fair faced
concrete surfaces.
Internal Ceiling

F
G

Supply and fix 12 mm thick decorative suspended gypsum


board ceiling including emulsion paint, galvanized steel
concealed suspension system, supporting, fitting and all
necessary accessories including grooves, trim, access panels,
as per drawings all complete to the Engineer's approval.
(Low Level)

Supply and fix 600 x 600mm moisture resistance gypsum tiles


PVC laminated including suspension and grid system, fitting
and necessary accessories as per drawings all complete to the
Engineer's approval.
Supply and fix 600 x 600mm aluminum tiles false ceiling with
concealed suspension system as per drawings all complete to
the Engineer's approval, including emulsion paint.

B8 - Finishes

Bills of Quantities and Dayworks

B8/45

Supply and fix 600 x 1200mm aluminum tiles false ceiling


with concealed suspension system as per drawings
all
Jabal Al-Ka'aba
complete to the Engineer's approval, including emulsion
paint.

Hotel
159

m2

150

23,850
0
0

FINISHES (Cont'd)

0
0

Internal Ceiling (Cont'd)

0
0
0
0

Bulk heads
A

Supply and fix 12mm thick gypsum board bulk head


including emulsion paint, galvanized steel suspension
system, supporting, fitting, trim, groove and accessories
complete as per drawings and specifications and to the
Engineer's approval.
Access panels
Supply & fix aluminum powder coated access panel,
including all accessories and locking device, to the
Engineer approval.

Item 300,000

300,000
0
0
0

Item

250,000
0

250,000

Painted Ceiling
C
D

0
0

Supply & apply spray plaster smooth finishing ceiling


with washable emulsion paint.
Supply & apply anti-carbonation coat on fair face
concrete.

2,816

m2

80

225,280
0

2,533

m2

100

253,300
0
0
0
0
0
0
0
0

45

m2

700

600

31,332
0
4,920
0

FINISHES (Cont'd)
External Finishes
Floors
A

Supply & fix 30mm thick cut to size granite tiles with
patterns at the main entrance to the Engineer approval.
(PC supply rate SAR 500/ m2)
Ditto, but for entrance steps.

0
0
0
0

Interlocking
C

Supply & fix 60mm thick precast concrete interlocking


paving including 40mm thick approved graded
compacted crushed sand, at set back area as drawings
and to the Engineer approval ( PC Rate 45 SAR/m2)

102

m2

80

8,160
0
0
0

130

80

10,400
0

Curbstone
D

Supply & fix precast colored concrete hydraulically


pressed curbstone bedded in cement and sand mortar
and hunched up behind with lean mix concrete and
including forming curves to radius, expansion joint,
jointing , complete as shown on drawings to the
Engineer approval.

B8 - Finishes

Bills of Quantities and Dayworks

B8/46

0
0

Granite Cill
E

Jabal Al-Ka'aba Hotel

Supply and fix granite cill as per drawings and


engineer's approval. (PC supply rate SAR 500/m2)

30

600

18,000
0
0
0

221

m2

120

26,520
0

43

m2

700

44

m2

700

30,100
0
30,450
0
0
0
0
0
0
0
0
0
0

Wall
F
G

Supply & apply Epoxy paint over 20mm thick cement


plaster.
Supply & fix (dry fix) 20mm thick cut to size granite
tiles at the main entrance to the Engineer approval. (PC
supply rate SAR 500/ m2)
Ditto, but for flower box at main entrance.

FINISHES (Cont'd)
External Finishes (Cont'd)
Precast Panels (including concrete pyramid shape)
A

Design ,manufacture, supply, fixing and erection of prefinished, sand blasted, thermally insulated architectural
precast panels on elevations, including supply and
erection of all the required accessories, fittings, grooves,
sealant, plants, equipment, etc... required for the precast
panels stability, tidiness and acoustic insulation
including preparation of shop drawings.
1

Item 1,000,000

1,000,000
0
0
0

100

4,700
0
0
0
0

Ceiling
B

Supply & apply epoxy based paint medium textured


apllied over cement plaster smooth finish.

47

m2

Additional Items
C

The Tenderer is requested to identify and list separately


in details and price any items of work not listed above
but shown in the drawings or mentioned in the
specification or required for satisfactory completion of
the work , any items not listed below shall be deemed to
be included.

Item

FINISHES
Collection

Amount : SAR

Page B8/1

B8 - Finishes

Bills of Quantities and Dayworks

B8/47

Page B8/2

20,798,047

Jabal Al-Ka'aba Hotel


Page B8/3

Page B8/4

Page B8/5

Page B8/6

Page B8/7

Page B8/8

Page B8/9

Page B8/10

Total of Bill No. 8 - FINISHES

SAR

To The Grand Summary

B8 - Finishes

Bills of Quantities and Dayworks

B8/48

Jabal Al-Ka'aba Hotel


Item

Item Description

Quantity Unit

Rate

Amount : SAR

SPECIALISTS
Traffic Barriers
A

Supply & installation of automatic traffic barriers


including access remote control automatic system,
stationary post, etc. complete as shown on drawing
including electrical work and should be interfaced with
the fire alarm and as such the arms will open
automatically once the fire alarm set off, including the
required numbers of remotes.

No

60,000

120,000
0
0
0

Ite
m

20,000

20,000
0
0

Traffic Road marking


B

Allow for Solvent -borne coating based on Alkyd resin


& chlorinated rubber Traffic marking as per drawings
and specifications.
Convex traffic mirrors.

0
0

Allow for convex reflective sturdy surveillance mirror


600mm dia in poly carbonate 100% aluminum mirror
foil treated with anti-graffit product with hexagonal
layer reflexes for dipped lights, mounted with rugged
polymer frame featured with a white edging strip and
red short light reflectors, including hot dipped
galvanized fitting with adjustable ball joint and an
adjustable arm sciurid to ceiling/ wall, complete as
directed by the Engineer.

Item 100,000

100,000
0
0
0
0

Item 500,000

500,000
0
0
0

Item 100,000

100,000
0
0
0
0

Column guards
D

Allow for 1000 mm high proprietary heavy duty vinyl


corner guards mounted on galvanized steel plate
continuous retainers plugged and bolted to columns
and walls corners in accordance with the drawings.
Ramp Wall guards

Supply & fix wall guard manufactured from high


impact resistant rubber to be placed as per the
Engineer approval to protect walls in the ramp area.
SPECIALISTS (Cont'd)

B9 - Specialists

Bills of Quantities and Dayworks

B9/49

Pipe guards
A

0
0
0

Jabal Al-Ka'aba Hotel

Allow for pipe guards where ever exposed pipe found in


parking area to the Engineer satisfaction.

Item 500,000

500,000
0
0
0

Item 200,000

200,000
0
0
0
0
0

Speed hump
B

Allow for speed hump as per drawings.

Garbage Chute
Allow for supply, install , testing and commission of
Garbage Chute System as per drawings and
specifications and to the Engineer's approval.

No

SPECIALISTS (Cont'd)
Additional Items
A

The Tenderer is requested to identify and list separately


in details and price any items of work not listed above
but shown in the drawings or mentioned in the
specification or required for satisfactory completion of
the work, any items not listed below shall be deemed to
be included.

Item

500,000

500,000
0
0
0
0
0
0

0
0

SPECIALISTS
Collection

Amount : SAR

Page B9/1

2,040,000
Page B9/2

Page B9/3
Total of Bill No. 10- SPECIALISTS
To The Grand Summary

B9 - Specialists

Bills of Quantities and Dayworks

B9/50

Jabal Al-Ka'aba Hotel


Item

Item Description

Quantity

Unit

Rate

Amount : SAR

PROVISIONAL SUMS
Provisional sums for works to be executed by
nominated Sub-contractors/ Suppliers, to be expended
in whole or in part, or not at all at the direction of the
Engineer.
Window cleaning system
Allow for supply, installation, testing & commissioning
of window cleaning system / by nominated
subcontractor .
B Add: Main Contractor's Profit

Sum

C Add: Main Contractors attendance


D Allow for all associated builders work in connection with
these works.

350,000

20

70,000

Sum

50,000

50,000

Sum

Doors, Building & Traffic Signage


E

Allow for supply & fix of doors, building & traffic


signage/ by nominated subcontractor.

Sum

F Add: Main Contractor's Profit


1

G Add: Main Contractors attendance

250,000

30

75,000

Sum

50,000

50,000

Kitchen , Laundry Equipment (including Linen Chute)


H

Allow for supply, installation, testing & commissioning


of kitchen, laundry equipment/ by nominated
subcontractor.

Sum

I Add: Main Contractor's Profit


1

J Add: Main Contractors attendance


K Allow for all associated builders work in connection with
these works.

3,700,000

20

740,000

Sum

100,000

100,000

Sum

PROVISIONAL SUMS (Cont'd)


Lifts
A

Allow for supply, installation, testing & commissioning


of lifts (including finishes for lift car) / by nominated
subcontractor (6 passenger lifts + 2 service lift + cargo
lift).
Sum

B12 - Provisional Sums

Bills of Quantities and Dayworks

6,000,000
B12/51

B Add: Main Contractor's Profit

Jabal Al-Ka'aba Hotel


1

C Add: Main Contractors attendance


D Allow for all associated builders work in connection with
these works.

20

1,200,000

Sum

200,000

200,000

Sum

Faade Lighting
E Allow for Faade Lighting works to be carried out by
Specialist Nominated Contractor.

Sum

F Add: Main Contractor's Profit


1

G Add: Main Contractors attendance


H Allow for all associated builders work in connection with
these works.

350,000

20

70,000

Sum

100,000

100,000

Sum

Ironmongery Works
I Allow for supply only Ironmongery Works for wooden
doors to be carried out by nominated supplier.

Sum

J Add: Main Contractor's Profit


1

K Add: Main Contractors attendance

700,000

20

140,000

Sum

150,000

150,000

Light Fittings works


L Allow for supply Light Fittings works to be carried out
by nominated supplier.

Sum

M Add: Main Contractor's Profit


1

N Add: Main Contractors attendance

1,000,000

20

200,000

Sum

150,000

150,000

PROVISIONAL SUMS (Cont'd)


Sanitary Ware, Fixtures & Accessories works
A Allow for supply Sanitary Ware, Fixtures & Accessories
works to be carried out by nominated supplier.

Sum

B Add: Main Contractor's Profit


1

C Add: Main Contractors attendance

3,800,000

21

798,000

Sum

500,000

500,000

Kitchen Cabinets, Built-in Wardrobes, Shoes Racks,


Lockers..etc
D

Allow for supply, installation & maintenace of kitchen


cabinets, built-in wardrobes, shoes racksetc. to be
carried out by nominated sub-contractor

B12 - Provisional Sums

Bills of Quantities and Dayworks

Sum

1,700,000
B12/52

E Add: Main Contractor's Profit

Jabal Al-Ka'aba Hotel


1

F Add: Main Contractors attendance


G Allow for all associated builders work in connection with
these works.

25

425,000

Sum

200,000

200,000

Sum

Mirrors
H

Allow for supply, installation & maintenace of mirrors,


to be carried oud by nominated sub-contractor.
Sum

I Add: Main Contractor's Profit


1

J Add: Main Contractors attendance

500,000

25

125,000

Sum

50,000

50,000

Sum

K Allow for all associated builders work in connection with


these works.
PROVISIONAL SUMS (Cont'd)
Counter Tops
A

Allow for supply, installation & maintenace of counter


tops, to be carried oud by nominated sub-contractor.
Sum

B Add: Main Contractor's Profit


1

C Add: Main Contractors attendance

1,000,000

35

350,000

Sum

200,000

200,000

Sum

D Allow for all associated builders work in connection with


these works.
Interior Design Package
E

Allow for supply, installation and maintenance of


interior design package/ by nominated subcontractor.

Sum

F Add: Main Contractor's Profit


1

G Add: Main Contractors attendance


H Allow for all associated builders work in connection with
these works.

By Owner

20

Sum

300,000

300,000

Sum

Tenderer is not entitled to any overhead and profit to:


I

Electrical Appliances

By Owner

All furniture.

By Owner

Item
B12 - Provisional Sums

Item Description

Quantity
Bills of Quantities and Dayworks

Unit

Rate

Amount : SAR
B12/53

Jabal Al-Ka'aba Hotel

PROVISIONAL SUMS (Cont'd)


Prime Cost Sums

Prime cost sums for works to be carried out or materials


to be supplied or fees to be paid in respect of statutory
authority, to be expended in whole or in part or not at all
at the direction of the Engineer.
A

Supply, installation, testing, commissioning of substation equipment including transformers, ring main
units, power cables in between transformers & main
distribution boards/ air circuit breakers, from ring
main unit to EWA supply network, KWH meters,
electricity connection charges, power supply connection
charges.
Prime cost sum for the drainage, water supply
connection charges.

Item 3,000,000

3,000,000

Item

1,500,000

PROVISIONAL SUMS
Collection

Amount : SAR

Page B12/1

30,093,000

Page B12/2

Page B12/3

Page B12/4

Page B12/5
Total of Bill No. 12 - PROVISIONAL SUMS
To The Grand Summary

B12 - Provisional Sums

Bills of Quantities and Dayworks

SAR

B12/54

Jabal Al-Ka'aba Hotel

Item Description

Amount : SAR

Grand Summary

Jabal Al-Ka'aba Hotel - KSA

B1 General Requirements

Grand Summary

B2 Site Work

7,166,740

B3 Concrete Work

57,413,334

B4 Masonry

3,140,073

B5 Metal Work

1,772,994

B6 Thermal & Moisture Protection

4,078,297

B7 Doors & Windows

9,124,250

B8 Finishes

20,798,047

B9

2,040,000

Specialists

B10 Mechanical Engineering Installations

37,510,705

B11 Electrical Engineering Installations

56,862,560

B12 Provisional Sums

30,093,000

Bills of Quantities and Dayworks

GS/1

Jabal Al-Ka'aba Hotel

Grand Summary

Bills of Quantities and Dayworks

GS/1

Jabal Al-Ka'aba Hotel


Tenderers are advised to fill the next with the overhead and profit
Overhead

Profit

Total of Grand Summary


To the Form of Tender

Grand Summary

Bills of Quantities and Dayworks

230,000,000

SAR

total
230,000,000

GS/1

Jabal Al-Ka'aba Hotel

t : SAR

Grand Summary

Bills of Quantities and Dayworks

GS/1

Jabal Al-Ka'aba Hotel

Grand Summary

Bills of Quantities and Dayworks

GS/1

Jabal Al-Ka'aba Hotel

Grand Summary

Bills of Quantities and Dayworks

GS/1

Jabal Al-Ka'aba Hotel

Item

Item Description

A General Notes
Day works will be administered strictly in accordance with Clause 52.4 of the Conditions of Contract.
The Contractor will be paid for Day Works carried out during the course of the works, while other
operations are in progress, at the rates set out in this schedule. Profits and Overheads are not to be
included in the actual rates but stated as a percentag
The basic unit rates to be inserted in the Day Works Schedule shall be the rates, which the Contractor
has used in determining his unit rates inserted elsewhere in these Tender Documents.
Actual time engaged in the works only will be allowed. In the event of Labor or Plant having to be
brought to the site specifically for an item of Day work, then a reasonable allowance for traveling
time shall be considered. Any such allowance shall be ag
B General Notes on Rates for Labor
The Day Work rates quoted for labor are to be the net amount payable, including wages, bonuses and
all other allowances paid to the operatives directly engaged on Day Works. The Day Work rates shall
include for the use of hand tools and consumables, ordin
No special rates for working overtime will be admissible unless specifically authorized by the
Engineer in writing.
The cost of all supervisory and administrative staff, including Engineers, Foremen, Clerks, Store
men, Secretaries, Assistants etc. is to be included in the percentage addition for overheads and profits.
C General Notes on Rates for Material
Materials used in Day Works shall be as specified elsewhere for the works. The rates are to be the net
invoice price including the cost of delivery to the site. In the event of any material not included in the
Schedule is to be used in an item of Day Work
General Notes on Rates for Plant

Plant hire rates hall include for the cost of maintaining in proper working order, insurance, fuel and
all consumables, cleaning material, replacement and/or sharpening of tools and the like.
Idle time, maintenance or
traveling time to the site will not
The
actual cost of hiring plant not listed in the Schedule will be paid based on the Contractor's
be considered.
invoices. Competitive quotations must be obtained for all plant hired. In the event of Contractor's
own plant and equipment being used, a reasonable rate bas
E General Notes on Percentage Addition
The percentage inserted at the item provided at the end of each section shall, in addition to any item
referred to previously, include for the following: overheads and profits, supervisory and
administrative staff, establishment costs, all costs related t

Dayworks

Bills of Quantities and Dayworks

61/81

Jabal Al-Ka'aba Hotel

Item

Item Description

Quantity

Unit

Rate

A Laborers / helpers.

500

Hr

15.00

B Scaffolders.

150

Hr

25.00

C Steel fixers.

250

Hr

35.00

D Drainage layers.

100

Hr

25.00

E Carpenters and Joiners

250

Hr

35.00

F Plasterers.

250

Hr

30.00

G Block layers, masons and tie fixers

250

Hr

30.00

H Plumbers.

150

Hr

35.00

Painters.

150

Hr

30.00

Electricians./Ac mechanics

150

Hr

30.00

K Plant and machinery operators and drivers (Light D

100

Hr

30.00

L Plant and machinery operators and drivers (Heavy

100

Hr

40.00

M Welders.

100

Hr

25.00

N Pipe Fitter.

100

Hr

25.00

O Metal Worker.

100

Hr

30.00

P Attendant.

100

Hr

35.00

Q Charge hand.

100

Hr

30.00

R Non-supervisoury working foremen

100

Hr

40.00

Amount : SAR

Labor
7,500
0
3,750
0
8,750
0
2,500
0
8,750
0
7,500
0
7,500
0
5,250
0
4,500
0
4,500
0
3,000
0
4,000
0
2,500
0
2,500
0
3,000
0
3,500
0
3,000
0
4,000
0
0
0
0
0

Percentage Addition
S Allow for all other cost and charges.

Dayworks

Bills of Quantities and Dayworks

62/81

Material
A Building Sand

50
Jabal Al-Ka'aba Hotel

00
2,5000

m3

50.00

10

Ton

400.00

C Sulphate Resistant Cement.

10

Ton

500.00

D Coarse aggregate.

25

80.00

E Fine aggregate.

25

100.00

F Reinforcement bars (high yield, deformed).

Ton

5,000.00

G Reinforcement bars (Mild steel)

Ton

4,500.00

H Concrete grade 20.

10

250.00

Concrete grade 40.

10

400.00

Concrete grade 45.

10

450.00

K Concrete grade 50.

10

500.00

L GGBS (30%)

M GGBS (60%)

N Microsilica (5%)

250.00

250
0

O Form work.

20

m2

150.00

P Solid cement blocks 100 mm thick.

500

No.

3.00

3,0000
1,5000

Q Solid cement blocks 150 mm thick.

500

No.

4.00

R Solid cement blocks 200 mm thick.

500

No.

5.00

2,0000
2,5000

S Hollow cement blocks 100 mm thick.

500

No.

T Hollow cement blocks 150 mm thick.

500

No.

3.00
4.00
4.00

1,5000
2,0000

U Hollow cement blocks 200mm thick.

500

No.

5.00

2,5000

V AAC blocks 100 mm thick.

100

m2

00

W AAC blocks 150 mm thick.

100

m2

00

X AAC blocks200 mm thick.

100

m2

00

Y AAC blocks 250mm thick.

100

00

Z AAC blocks 300mm thick.

100

m2

00

AA 12mm Plywood

30

m2

300.00

9,0000

AB 18mm plywood

30

m2

400.00

AC Epoxy Paint

200

liter

50.00

12,0000
10,0000

AD Emulsion Paint

200

liter

40.00

AE Enamel Paint

200

liter

40.00

B Ordinary Portland Cement.

4,0000
5,0000
2,0000
2,5000
25,0000
9,0000
2,5000
4,0000
4,5000
5,0000
00
00

8,0000
8,000
0

Percentage Addition
AF Allow for all other costs and charges.

00
0
0
0
0
0
30,000
0
10,000
0

Plant
A Concrete mixer.

20

Hr

1,500.00

B Dump truck (10 tone).

50

Hr

200.00

Dayworks

Bills of Quantities and Dayworks

63/81

C Pneumatic breaker with hoses and fittings.


D Dumper 0.53 m3 capacity.

50

50
Jabal Al-Ka'aba Hotel

Hr

150.00

Hr

60.00

E Dumper 1 m3 capacity.

50

Hr

80.00

F Drill machines.

20

Hr

25.00

G Tower Crane.

50

Hr

20,000.00

H Mobile crane (10 Ton).

50

Hr

5,000.00

Mobile crane (50 Ton).

50

Hr

10,000.00

Mobile crane (100 Ton).

50

Hr

15,000.00

K Light Vehicle (2 Ton).

20

Hr

500.00

L Material hoist.

50

Hr

250.00

M Vibrator.

20

Hr

20.00

N Power float.

30

Hr

150.00

O Electric saw.

20

Hr

150.00

P Bar bending machine.

30

Hr

100.00

Q Excavator 1 m3 bucket capacity.

50

Hr

250.00

R Excavator 0.5 m3 bucket capacity.

50

Hr

200.00

S Heavy truck (20 Ton).

20

Hr

600.00

T Pneumatic compressor.

30

Hr

150.00

U Core cutting machine (2-12 inches).

20

Hr

250.00

V Bob cat.

20

Hr

100.00

W Welding plant.
X Electric Generator 50 KVA.
Y Electric Generator 10 KVA.

20

Hr

1,500.00

30

Hr

2,000.00

30

Hr

1,700.00

Z Concrete pump.

20

Hr

350.00

20

Hr

250.00

AA Truck mixer.
AB Water Pump 25 KW

7,500
0
3,000
0
4,000
0
500
0
1,000,000
0
250,000
0
500,000
0
750,000
0
10,000
0
12,500
0
400
0
4,500
0
3,000
0
3,000
0
12,500
0
10,000
0
12,000
0
4,500
0
5,000
0
2,000
0
30,000
0
60,000
0
51,000
0
7,000
0
5,000
0
0
0
0

Plant(Cont'd)
A Water tanker 4000 gal. capacity.

25

hr

150.00

B Ring hammer including the excavator.

20

hr

500.00

C Oxygen cutter.

20

hr

200.00

D Electric cutter.

20

hr

200.00

E Compactor.

30

hr

300.00

F Roller.

20

hr

150.00

Dayworks

Bills of Quantities and Dayworks

0
0
3,750
0
10,000
0
4,000
0
4,000
0
9,000
0
3,000
64/81

Percentage Addition

0
0
0
0

Jabal Al-Ka'aba Hotel

G Allow fro all other costs and charges.

Total of page 1
Total of page 2

3,035,400
Total of page 3
Total of page 4
Total of page 5
Total for Dayworks

Dayworks

Bills of Quantities and Dayworks

65/81

Preambles

B1- General Requirement

B2- Site Works

B3- Concrete Works

B4- Masonry Works

B5- Metal Works

B6- Thermal and Moisture Protection

B7- Doors and Windows

B8- Finishes

B9- Specialists

B10- Mechanical Works

B11- Electrical Works