BASIC PERFORMANCE DATA (Return Air Ceiling Diffusers)

SIZE

NECK
AREA

9 X 21

1.31

9 x 24

1.5

12 x15

1.25

12 x 18

1.5

12 x 21

1.75

12 x 24

2.0

15 x 18

1.875

15 x 21

2.185

15 x 24

2.5

18 x 21

2.625

18 x 24

3.0

21 x 24

3.5

NECK VELOCITY 250


P( R )
0.021
CFM
328
R.NC
21
CFM
375
R.NC
21
CFM
312
R.NC
20
CFM
375
R.NC
22
CFM
438
R.NC
23
CFM
500
R.NC
25
CFM
469
R.NC
21
CFM
548
R.NC
22
CFM
628
R.NC
24
CFM
655
R.NC
21
CFM
748
R.NC
23
CFM
871
R.NC
24

300
0.031
394
25
450
26
375
24
450
26
525
27
600
29
562
26
655
26
748
28
788
27
901
28
1053
28

400
0.055
525
31
600
33
500
31
600
32
700
33
800
35
750
32
875
32
1000
33
1050
33
1200
34
1400
33

500
0.086
656
36
750
38
624
36
750
36
875
36
1000
40
938
37
1095
38
1252
39
1313
39
1500
40
1748
38

600
0.125
788
41
900
44
750
39
900
41
1050
42
1200
43
1125
42
1312
43
1499
44
1575
44
1800
45
2100
43

700
0.170
918
44
1050
48
876
43
1050
46
1224
48
1400
48
1312
46
1529
47
1746
48
1838
48
2100
49
2452
49

800
0.220
1050
48
1200
53
1000
48
1200
51
1400
52
1600
53
1500
50
1750
51
2000
53
2138
54
2400
55
2800
54

NOTES:
SIZE
: Is the nominal neck size in inches.
NECK AREA : Is in square feet.

P( R ) :
R.N.C. :

Return pressure drop in inches W.G


Room NC for return based on 8db room effect.

For Square / Rectangular core styles with 1,2,3 or 4way airflow patterns

Performance Data

BALANCING PROCEDURE
To determine the CFM, follow up the following procedure:
1. Use measuring tools for air velocity like
ALNOR 2220-A lip or 2200 probe, or
Anemotherm air meter.
2. Take number of measuring points (should be
not less than 4) with the probe so located and adjusted as to measure the maximum air velocity to the
air flow direction on the face of the diffuser as shown.
3. Calculate the average measure velocity by using :

23

DIMENSIONAL DATA
A = Duct Size
Listed Size A-1/4 (6mm)

H*

22

V ( average ) = ( V1 + V2 + .. + Vk )
k
4. Determine the area factor Ak from table (6) considering the proper size .
5. Calculate CFM :
CFM = Ak x Vk

CEILING OPENING = LISTED SIZE +3 (76mm)


LISTED SIZE +5 5/8 (143mm)

CEILING DIFFUSERS DD-6


* NOTE:

H = 2 7/16 (62mm) WITHOUT DAMPER


H = 3 13/16 (97mm) WITH DAMPER

Balancing Procedure

PERFORATED CEILING DIFFUSERS


GENERAL
DASCO perforated ceiling diffusers DDP-6 are
designed especially for installation where a smooth
air flow as well as asymmetrical air diffusion is
required to meet with a certain HVAC application,
and yet with a pleasing appearance to suit
architectural requirements to flush outlets and
concealed fixing method.

DESCRIPTION

Perforated Ceiling Diffuser


(DDP - 64S)

DASCO perforated ceiling diffuser DDP- 6 is a multi-vane type with a fully and easily removable perforated
face with 4 mm diameter holes, 6 mm pitches and 40% of its face open, with square or round neck and
can be supplied in 1,2,3&4 way airflow patterns for all air distribution requirements. The diffuser can
also be supplied with an opposed blade damper section ( for supply diffusers only ) which in turns is
fixed to the outer frame of the diffuser and is lever operated from the face of the diffuser. Key operated
opposed blades damper can also be supplied upon request. The damper frame is separated from its blades
by using nylon bushings to eliminate corrosion and vibration. DDP-6 perforated ceiling diffuser is available
in square and rectangular patterns for supply air as well as for return-air and which in turn is supplied
without opposed blade damper as standard.

MATERIAL AND FINISH


High quality extruded aluminium in sliver anodized matt finish. Perforated face is of aluminium sheet
1.5 mm thickness.
White polyester powder coating finish or any other RAL standard colour are also available upon your
requirement.

Perforated Diffusers

ORDERING CODE
Supply Air Perforated Ceiling Diffuser

DDP - 6 a -

WxH

1,2,3,or 4 way airflow


patterns
S : Square type
L : Rectangular type
C: Corner type
WxH = Neck size, inch (mm)
NOTE:
When specifying a return air diffuser, use the symbol DDPR instead of DDP.

24
25

LISTED SIZES AVAILABLE


(24 X 24 perforated face module ).

Neck size (inch)

Neck size (inch)

6x6
9x9

12 x 12
15 x 15

Table ( 7 ) : Listed sizes available ( W x H )


for Perforated Ceiling Diffusers

Perforated Ceiling Diffuser (DDP - 64S)

Perforated Diffusers

BASIC PERFORMANCE DATA


PERFORATED SUPPLY AIR CEILING DIFFUSERS
B
A

NECK
A B
VELOCITY 250
P(s)
0.015

SIZE NECK PATTERN


AREA
6
X

0.25

X
9

SIZE NECK

X
12

1.0

A
B
800
0.172

CFM

63

75

100

125

150

175

200

S.NC

< 18

20

22

25

29

34

38

2-4

3-5

4-6

5-7

6-8

7-9

8-10

DDP-63S

THROW

2-4

3-5

4-6

5-7

6-7

6-8

7-9

DDP-62S

THROW

2-3

2-4

3-5

4-6

5-6

5-7

6-8

DDP-61S

THROW

2-3

3-4

3-5

4-5

5-6

6-7

CFM

140

169

225

281

338

394

450

S.NC

< 18

20

23

26

31

36

42

DDP-64S

THROW

3-5

5-7

7-9

8-11

10-12

11-14

13-16

DDP-63S

THROW

3-5

4-6

5-8

7-10

9-11

10-12

11-14

DDP-62S

THROW

2-4

4-5

5-7

6-9

8-10

9-11

10-12

DDP-61S

THROW

2-3

3-5

4-6

5-7

7-9

8-10

9-11

PATTERN

CFM

250

300

400

500

600

700

800

S.NC

19

22

25

28

34

39

45

DDP-64S

THROW

4-6

6-8

8-11

10-14

12-16

14-19

16-22

DDP-63S

THROW

4-6

5-7

7-10

9-13

11-14

12-17

14-19

DDP-62S

THROW

3-5

4-6

6-8

8-11

10-13

11-15

12-17

DDP-61S

THROW

3-4

4-5

5-7

7-9

8-11

10-14

11-15

AREA
12

A
B A
B
600
700
0.94
0.13

THROW

AREA
0.56

A
B
500
0.066

DDP-64S

SIZE NECK PATTERN

A
B A
B
300
400
0.023 0.041

Performance Data

SIZE

6
X
6

SIZE

9
X
9

SIZE

12
X
12

BASIC PERFORMANCE DATA


PERFORATED SUPPLY AIR CEILING DIFFUSERS
B
A

NECK
A B
VELOCITY 250
P(s)
0.015

SIZE NECK

PATTERN

1.56

15

A
B
500
0.066

A
B A
B
600
700
0.94
0.13

A
B
800
0.172

CFM

390

469

625

781

938

1095

S.NC

20

23

27

32

38

44

50

DDP-64S

THROW

5-7

8-10

10-13

12-16

15-20

18-23

20-26

DDP-63S

THROW

5-6

7-9

9-11

11-14

13-18

16-21

18-23

DDP-62S

THROW

4-5

6-8

8-10

10-12

11-16

14-18

16-20

DDP-61S

THROW

3-4

5-7

7-9

9-11

10-14

12-16

14-18

AREA
15

A
B A
B
300
400
0.023 0.041

1250 SIZE

15
X
15

26
27

PERFORATED RETURN AIR CEILING DIFFUSERS


SIZE

NECK
AREA

6x6

0.25

9x9

0.56

12 x12

1.0

15 x 15

1.56

NOTES:
SIZE
NECK AREA
PATTERN
P(s)

:
:
:
:

NECK VELOCITY
P( R )
CFM
R.NC
CFM
R.NC
CFM
R.NC
CFM
R.NC

250
0.019
63
<18
140
19
250
20
390
21

Is the nominal neck size in inches.


Is in square feet.
Is flow pattern as detailed previously.
Supply pressure drop in inches W.G.

300
0.032
75
20
169
21
300
23
469
24

400
0.059
100
23
225
24
400
26
625
29

500
0.091
125
26
281
27
500
30
781
35

600
0.115
150
30
338
32
600
35
938
40

700
0.148
175
36
394
37
700
40
1095
46

800
0.198
200
39
450
43
800
47
1250
52

SIZE

6x6
9X9
12 x12
15 x 15

P(R)
: Return pressure drop in inches W.G.
THROW : In feet corresponding to 100 & 50 FPM terminal
velocity.
S.NC
: Room NC for supply based on 8 db room effect.
R.N.C. : Room NC for return based on 8 db room effect.

Performance Data

ACCESSORIES
SQUARE TO ROUND ADAPTER - AD

Listed Sizes Available

Square to Round Adapter - AD

Square
Neck

Dia
D

Square
Neck

Dia
D

6x6
9x9
9x9
12 x 12
12 x 12
15 x 15
15 x 15
15 x 15
18 x 18

5
6
8
8
10
10
12
14
12

18 x 18
18 x 18
21 x 21
21 x 21
21 x 21
21 x 21
24 x 24
24 x 24
24 x 24

14
16
14
16
18
20
16
18
20

Table 8. Listed sizes available of


Square to Round Adapters

D-1/4

SQUARE NECK

The AD is designed as transition adapter permitting the attachement of round flexible or rigid duct to a
square neck diffuser.
The AD is recommended as an accessory for the DD-6/DDP-6 series square neck diffuser.
Galvanized steel construction . With polyster powder coating finish as optional.

Accessories

EQUALIZING GRID - EG

EG is made of extruded aluminium construction.


The blades are fitted in Nylon bushing to prevent
noise.
The EG is designed to assure precision control
and distribution of air flow, through stub duct
and into the neck of the diffuser, The EG are
bracket mounted to ducts.
Equalizing Grid - EG

The blades are easy adjustable at any desired


28

degree individually.
29

Single Element

Multi Elements

Ceiling Diffusers with Round Plastic Cores

Accessories

CONVERSION TABLE

Quantity

Area

Density

Imperial Unit

Metric Unit

From Imperial To

From Metric To

Metric Multiply By

Imperial Multiply By

Square foot

Square meter (m2)

0.0929

10.764

Square inch

Square millimeter (mm2)

645.16

0.00155

Pounds per cubic foot

Kilograms per cubic

16.018

0.624

meter (kg/m )
Length

Pressure

inch

millimeter (mm)

25.4

0.0394

foot

millimeter (mm)

304 .8

0.00328

foot

meter (m)

0.3048

3.2808

yard

meter (m)

0.9144

1.0938

inch of water column

Kilopascal (kPa)

0.2486

4.0219

foot of water column

Kilopascal (kPa)

2.9837

0.3252

inch of mercury column

Kilopascal (kPa)

3.3741

0.2964

ounces per square inch

Kilopascal (kPa)

0.4309

2.3206

pounds per square inch

Kilopascal (kPa)

6.8948

0.145

5/9 (F-32)

(9/5 C) +32

Temperature fahrenheit

celcius (C)

Velocity

feet per second

meters per second (m/s)

0.3048

3.2808

feet per minute ( fpm)

meters per second (m/s)

0.00508

196.85

miles per hour

meters per second (m/s)

0.44704

2.2369

0.4719

2.119

0.0004719

2119.0

Volume Flow Cubic feet per minute (cfm)

Liters per second (L/s)


3

Cubic feet per minute (cfm)

Cubic meters per second (m /s)

Cubic feet per hour ( cfh)

Milliliters per second( ml/s)

7.8658

0.127133

Gallons per minute(U.S.)

Liters per second( L/s)

0.6309

15.850

Gallons per minute(imperial) Liters per second( L/s)

0.7577

13.198

Table 9. Metric guide conversion factors

Conversion Table

TESTING AND APPROVAL


Different samples from DASCO air terminal devices (Ceiling Diffusers)
were tested at ITS (Intertek Testing Services) labs in accordance with:

Air diffusion council test code for Ceiling diffusers No.

ISO 5219 Air distribution and air diffusion laboratory

aerodynamic testing and rating of air terminal devices.


ANSI/ASHRAE 70-1991, Method of testing for rating the
performance of air outlets and inlets.

30
31

CEILING DIFFUSERS WERE TESTED FOR:


A)
B)
C)
D)

Sound (NC Noise Criteria).


Static pressure in inches W.G.
Throw, feet.
Ak (Area factor).

Testing & Approval

COATING WITH POWDER


NOW YOU CAN ACHIEVE OPTIMAL COATING PERFORMANCE
ON ALL PRODUCTS YOU PAINT!

DASCO offers a first class service by introducing a wide range of perfect


polyester powder coating on all of its aluminium products of air terminal
devices.
The best quality of polyester powder Corro-Coat are used in according to the
international standards (BS,ISO,DIN,ASTM). PE-F architectural grade polyester
powders are used perfectly with pre-treatment, electrostatic spray and curing
in accordance with the above standards recommendations.
A complete range of RAL-Standard colours are always available in addition
to a vast range of special compound colours as per our customers request.
RAL Standerd Colour Chart Swatch

Now producing relief knots as in natural wood

New Technology Excellence


32
33

1.
2.

Resistance to high radiation and extreme climatic conditions.


It can be used in painting elaborate geometrical shapes producing
perfect quality and aesthetic results.

3.

It is the only technology that can replace wood in traditional areas.

New Mahogany - 21

New Mahogany - 22

Você também pode gostar