ONLINE UPS

A11J

Highly Reliable and Efcient Online UPS

A11J

ONLINE UPS

UL1778-4th (E226092), CE
Input

Output

100 V AC

100 V/200 V AC

single-phase 2-wire

single-phase 3-wire

or

or

200 V AC

100 V AC

single-phase 2-wire

single-phase 2-wire

Output capacity

Battery backup time

5/10 kVA

5min

min

*1

*2

*13U type with a load factor of 0.8.


*24U type with a load factor of 0.75.

Optional battery

200 V AC

*3

single-phase 2-wire

100 V/200 V AC

200 V AC
single-phase 2-wire

single-phase 3-wire

5/10/15/20 kVA

min

or

100 V AC

*3

*3

15min 25min 35min 45min


min

*3

min

*3There are some restrictions on the combination with the


installation method and output capacity.

single-phase 2-wire

*UL/CE certified models are available only for 200 V AC input and output and 5-minute backup time.
See the model list on page 6.

Parallel redundant operation

Single unit operation and parallel operation

Output capacity

Output capacity

5 kVA

10 kVA

15 kVA

5 kVA

10 kVA

15 kVA

(4.5 kW)

(9 kW)

(13.5 kW)

(4.5 kW)

(9 kW)

(13.5 kW)

20 kVA
(18 kW)
ULCE certified UPS unit17 kW

Highly Reliable Online UPS Achieved a High Efciency of 93%.*4

1 High Efciency
2 High Reliability

5 kVA

3 Expandable Capacity
4 Space-saving Design

10 kVA

5 Able to Supply Power to High Power Factor Devices

20 kVA

6 Easy Maintenance
7 LCD Display Panel for Monitoring Operational Status
*4In case of 5 kVA single unit type

Mounting examples

Vertical mounting.

19-inch rack mounting.

You can change the orientation of the front LCD display panel.

Optional rack support rails are available.

1 High Efciency
High 93% efciency (with the 5 kVA single unit model).
Reduces running cost and helps conserve energy.

Efciency of

93

Commercial
power supply

Device

2 High Reliability
Periodic automatic battery operation tests ensure reliable operation during a power outage.
*You can select the frequency of the battery operation test from 1, 3 and 6 months. The factory setting is 6 months.
Start operation test

Normal operation

Commercial
power supply

Rectier
Booster

Check battery power supply

Inverter

Device

Periodic
check

Commercial
power supply

Rectier
Booster

Inverter

Device

Battery

Battery

Return to normal operation

*If deterioration in battery performance is detected during


the battery operation test, normal operation is resumed.

3 Expandable Capacity
You can connect up to four 5 kVA UPS units in parallel to expand capacity up to 20 kVA.

Single unit/parallel operation


(N-unit setting)
Parallel redundant operation
(N+1-unit setting)

5 kVA/4.5 kW

Collection unit

Collection unit

10 kVA/9 kW

15 kVA/13.5 kW

5 kVA/4.5 kW

10 kVA/9 kW

Collection unit

20 kVA/18 kW
ULCE certified UPS unit17 kW

15 kVA/13.5 kW

4 Space-saving Design
The compact 3U size of the 5 kVA UPS unit (for 5-minute backup) allows you to mount it in an

EIA 19-inch rack.

3U size
(130 mm)
(5.12 inch)

5 Able to Supply Power to High Power Factor Devices


A 0.9 load power factor enables the unit to supply power to high power factor devices such as

servers.
Output capacity of 5

kVA

4.5 kW max.

Output capacity of 20

kVA

18 kW max.
UL/CE certified unit: 17 kW max.

6 Easy Maintenance
Front removable battery pack and inverter provide easy

maintenance.
*You can replace the battery pack without interrupting inverter power
supply operation.

A built-in maintenance bypass circuit allows you to

perform maintenance when power is being supplied.


*The maintenance bypass circuit is not available for UL/CE certied
models.

7 LCD Display Panel for Monitoring Operational Status


A back light LCD display panel allows you to easily monitor

the operational status and perform operation.

Options

LAN Interface Card

SANUPS SOFTWARE

A LAN interface card (10 0BaseTX) can be inserted in the optional


card slot. This allows for continuous
monitoring and reporting of
power supply conditions and quick
response during power failures.
Po w e r p r o b l e m s c a n a l s o b e
reported to the system manager via
e-mail when the card is installed.

The optional software increases


the reliability and manageability
of the entire system, including the
network and the server. It provides
UPS information to the system
manager, and flexible settings for
handling power-related problems.
Supported operating systems
Model: PRLANIF001

Windows (Japanese / English)


Linux (Japanese / English)
Unix (Japanese / English)

Battery Box, Battery Board, Rack Support Rails, and Transformer Box see the models and dimensional drawings on page 11.

External View

5kVA Front

20kVA Front

Model: A11J502****T/N

Model: A11J203S****

Input LED
Backup LED
LCD

Inverter ON/OFF
Switch

Warning LED

Input LED
Output LED
Alarm LED

Input Switch
Menu Operation Switch

Inverter ON/OFF Switch


Maintenance Bypass
Switch (Inside Cover)
* This is not available for
UL/CE certified units

Output LED

5kVA Back

Model: A11J502****T Terminal Block Type


Optional Battery Connector
Output Receptacle
(NEMA L6-30R)

External Control
Terminal
(EPO and Remote ON/OFF)
Card Interface

20kVA Back

Model: A11J203S****

Optional Battery
Connector

Cooling Fan
I/O Connector

Unit-to-Unit Interface

Output Receptacle Breaker


(for IEC-C13)

Optional Slot

Output Receptacle
(IEC-C132)

Contact
Signal Interface

External Control
Terminal
(EPO and Remote
ON/OFF)
Card Interface

PC Interface
I/O Terminal Block
Maintenance Bypass Switch
Output Receptacle Breaker (for L6-30R)

PC Interface
Contact Signal Interface
Optional Slot
I/O Connector
x 4 Sets

Cooling Fan
Unit-to-Unit Interface B
Unit-to-Unit Interface A
I/O Terminal Block

5kVA UL/CE Certified Unit Back

20kVA UL/CE Certified Unit Back

Model: A11J502****T Terminal Block Type

Model: A11J203S****
Cooling Fan

External Control Terminal (EPO and Remote ON/OFF)

Card Interface

I/O Connector

Unit-to-Unit Interface

Optional Slot

External Control
Terminal
(EPO and Remote
ON/OFF)

Contact
Signal Interface
PC Interface

Card Interface
I/O Terminal Block
Cooling Fan
Unit-to-Unit Interface B

PC Interface
Contact Signal Interface
I/O Terminal Block

I/O Connector
x 4 Sets

Unit-to-Unit Interface A

Optional Slot

Specication
Model A11J502A002T

Item
Feature
Rated output capacity
(Apparent power/Active power)

N unit setting

Single / Terminal block

Single / NEMA Plug

5 kVA 4.5 kW

5 kVA 4.5 kW

N+1 unit setting

Capacity increasable (with 20 kVA Power Distribution Unit)


System

5 kVA 4.5 kW

A11J203SA002

10 kVA 9 kW

15 kVA 13.5 kW

20 kVA18 kW*7

5 kVA 4.5 kW

10 kVA 9 kW

15 kVA 13.5 kW

*2

True online power supply synchronized with commercial power source


Forced air cooling
High-frequency PWM
VFI-SS-111

Rated voltage

200 V, 208V, 220V, 230V, 240V (User settable. Factory setting: 200V) (Acceptable voltage range: -40% to +15%) *3

Rated frequency

50Hz / 60Hz (Selectable Auto-detect or Constant frequency *4 Factory setting: Auto-detect)

Number of phase

Single-phase 2 wires

Power factor

Min. 0.95 (At rated input voltage and input voltage distorsion rate under 1%)

Max. capacity (at battery N unit setting


recovery charging)

5.5 kVA or less

N+1 unit setting

Number of phase

5.5 kVA or less

5.5 kVA or less

11 kVA or less

16.5 kVA or less

22 kVA or less

6.2 kVA or less

11.7 kVA or less

17.2 kVA or less

Single-phase 2 wires

Rated voltage (same as input)

200V, 208V, 220V, 230V, 240V (User settable. Factory setting: 200V) (Acceptable voltage range: -40%~+15%) *3

Voltage accuracy

Within 2% of rated voltage

Rated frequency (same as input)

50Hz / 60Hz

Frequency accuracy

Within 1, 3, 5% of rated frequency (Within 0.5% at UPS free running ) *5

Distortion factor of voltage

Linear load: 3% or less / Rectier load: 8% or less (at rated output)

Transient
voltage
variation

Rapid load factor change

Within 5% of rated voltage (0 100% rapid change)

Power outage / recovery

Within 5% of rated voltage

Rapid input voltage change

Load power factor

Within 5% of rated voltage ( 10% rapid change)


0.9 (lag)

N unit setting

110% or more (Automatic swith to bypass) *6

Overcurrent
protection

N+1 unit setting

N unit setting
Inverter
Overload
Bypass

220% or more
165% or more
147% or more
(Automatic switch (Automatic switch (Automatic switch
to bypass)*6
to bypass)*6
to bypass)*6

220% (1 minute)
165% (1 minute)
147% (1 minute)
236% (immediately) 177% (immediately) 157% (immediately)

400% (30 seconds) 300% (30 seconds) 267% (30 seconds)


1600% (2 cycles)
1200% (2 cycles)
1067% (2 cycles)

110% (1 minute) / 118% (immediately)

N+1 unit setting


N unit setting

capacity

Battery

A11J153SA002

Capacity increasable / Parallel redundantable*1

Cooling system

IEC Standard

AC
output

A11J103SA002
A11J103A002T

A11J502SA002

Power supply system


Inverter system

AC
input

A11J502A002N

200% (30 seconds) / 800% (2 cycles)

N+1 unit setting

Type

Small-sized sealed lead-acid battery

Battery runtime

5 minutes (3U type, Ambient temperature 25 degree C, load power factor 0.8, Default value)
10 minutes (4U type, Ambient temperature 25 degree C, load power factor 0.75, Default value)

Expected service life

5 years (Ambient temperature 25 degree C)

Acoustic noise (1m from front of equipment, A characterictics )

45 dB or less

45 dB or less

45 dB or less

50 dB or less

50 dB or less

50 dB or less

Heating value (at rated output after full recharged)

339 W or less

339 W or less

339 W or less

678 W or less

1062 W or less

1355 W or less

Operating
environment

Ambient Temperature

0 to 40 degree C

Relative humidity

20 to 90% no dew condensation

*1: A11J103(T) is not a capacity increasable.


*2: A11J103(T) does not have 20 kVA power distribution unit.
*3: AC input voltage range changes by load factor. Load factor 70% or less: -40% to +15% / More than 70%: -20% to +15%
A11J502(N) (NEMA plug type) is as follows. Load factor 70% or less: -40% to +15% / More than 70%: -10% to +15%
*4: Input frequency range is 8% at auto-detect setting. At constant frequency setting, the acceptable range is from 40Hz to 120Hz.
*5: At auto-detect frequency setting, the synchronized frequency range is selectable as 1%, 3% or 5% (factory setting: 3%).
At constant frequency setting, output frequency is xed to 50Hz or 60Hz without regard to input frequency.
*6: A conditions to switch to bypass synchronously are as follows.
Frequency auto-detect setting is selected. Input frequency is in the synchronized range and input voltage is in the rated voltage range.
*7 Reted active power of UL and CE approval model is 17 kW.

Model List
Model
Backup time 5
Backup time 10
minutes (3U type) minutes (4U type)

Input
voltage

Output
Capacity expansion/
Output
capacity parallel redundant
voltage
(kVA)
operation

Vertical
mounting

Rackmounting

UL/CE certied
unit

Optional battery
Remark
(min) *9

A11J502A002T

A11J502A002T-4U

200 V

200 V

Available (backup
time: 5 min only)

15253545
3060180

Terminal
block type

A11J502A002N

A11J502A002N-4U

200 V

200 V

15253545
3060180

NEMA plug
type

200 V

200 V

10

Only parallel redundant


operation is possible,
and capacity cannot be
expanded

152535
3060180

Available (backup
time: 5 min only)

3060180

A11J103A002T

A11J502SA002

A11J502SA002-4U

200 V

200 V

A11J103SA002

A11J103SA002-4U

200 V

200 V

10

A11J153SA002

A11J153SA002-4U

200 V

200 V

15

A11J203SA002

A11J203SA002-4U

200 V

200 V

20

A11J502SA002RM

A11J502SA002RM-4U

200 V

200 V

A11J103SA002RM

A11J103SA002RM-4U

200 V

200 V

10

A11J153SA002RM

A11J153SA002RM-4U

200 V

200 V

15

A11J203SA002RM

A11J203SA002RM-4U

200 V

200 V

20

15253545

Available (backup
time: 5 min only)

152535
1525
15

*9: The optional battery pack is used in conjunction with a UPS with a backup time of 5 minutes (3U type). When using an optional battery pack, the model number will
change. Please contact Sanyo Denki.

Specication
Model A11J502WA001

Item
Rated output capacity
(Apparent power/Active power)

N unit setting
N+1 unit setting

True online power supply synchronized with commercial power source


Forced air cooling

Inverter system

High-frequency PWM

A11J203WA002
20 kVA 18 kW

10 kVA 9 kW

15 kVA 13.5 kW

VFI-SS-111

Rated voltage

100 V or 200 V (Swith at terminal)


Acceptable voltage range: -35% to +15% *1

Rated frequency

50Hz / 60Hz (Selectable Auto-detect or Constant frequency *2 Factory setting: Auto-detect)

200 V
Acceptable voltage range: -40% to +15% *1

Number of phase

Single-phase 2 wires

Power factor

Min. 0.95 (At rated input voltage and input voltage distorsion rate under 1%)

Max. capacity (at battery N unit setting


recovery charging)
N+1 unit setting

6 kVA or less

Number of phase

Single-phase 2 wires or single-phase 3 wires

12 kVA or less

6 kVA or less

6.7 kVA or less

12 kVA or less

18 kVA or less

24 kVA or less

6.7 kVA or less

12.7 kVA or less

18.7 kVA or less

Rated voltage (same as input)

100 V (Single-phase 2 wiries), 100 V/200 V (Single-phase 3 wires) (Switch at terminal)

Voltage accuracy

Within 5% of rated voltage

Rated frequency (same as input)

50Hz / 60Hz

Frequency accuracy

Within 1, 3, 5% of rated frequency (Within 0.5% at UPS free running)

Distortion factor of voltage

Linear load: 3% or less

Rapid load factor change

Within 5% of rated voltage (0 100% rapid change)

Power outage / recovery

Within 5% of rated voltage

Rapid input voltage change

Within 5% of rated voltage ( 10% rapid change)

Load power factor

0.9 (lag) (Fractuation range at linear load: 0.7 (lag) to 1.0)

N unit setting
Overcurrent
protection
N+1 unit setting

104% or more (Automatic swith to bypass) *3

Overload
capacity

208% or more
156% or more
138% or more
(Automatic switch (Automatic switch (Automatic switch to
to bypass) *3
to bypass) *3
bypass) *3

208%(1 minute)/
224% (immediately)

156% (1 minute)/
168% (immediately)

138% (1 minute)/
149% (immediately)

400%
(30 seconds)/
1600% (2 cycles)

300%
(30 seconds)/
1200% (2 cycles)

267%
(30 seconds)/
1067% (2 cycles)

104% (1 minute) / 112% (immediately)

N+1 unit setting


N unit setting

Bypass

208% or more
(Automatic switch
to bypass) *3

N unit setting
Inverter

Battery

5 kVA 4.5 kW

A11J153WA002
15 kVA 13.5 kW

Cooling system

Transient
voltage
variation
AC
output

A11J103WA002

Power supply system

IEC Standard

AC
input

A11J502WA002

5 kVA 4.5 kW 10 kVA 9 kW

5 kVA 4.5 kW

Capacity increasable (with 20 kVA Power Distribution Unit)


System

A11J103WA001

5 kVA 4.5 kW 10 kVA 9 kW

208% (1minute)/
224% (immediately)

200% (30 seconds) / 800% (2 cycles)

N+1 unit setting

400%
(30 seconds)/
1600% (2 cycles)

Type

Small-sized sealed lead-acid battery

Battery runtime

5 minutes (3U type, Ambient temperature 25 degree C, load power factor 0.8, Default value)
10 minutes (4U type, Ambient temperature 25 degree C, load power factor 0.75, Default value)

Expected service life

5 years (Ambient temperature 25 degree C)

Acoustic noise (1m from front of equipment, A characterictics)

50 dB or less

55 dB or less

50 dB or less

55 dB or less

55 dB or less

55 dB or less

Heating value (at rated output after full recharged)

556 W or less

1112 W or less

556 W or less

1112 W or less

1669 W or less

2225 W or less

Ambient Temperature
Operating
environment Relative humidity

0 to 40 degree C
20 to 90% no dew condensation

*1: AC input voltage range changes by load factor.


AC input 100 V Load factor 70% or less: -35% to +15% / More than 70%: -15% to +15%, AC input 200 V Load factor 70% or less: -40% to +15% / More than 70%: -20% to +15%
*2: At auto-detect frequency setting, synchronized frequency range is selectable as 1%, 3% or 5% (factory setting: 3%).
Input frequency range is 8% at this setting. At constant frequency setting, output frequency is xed to 50Hz or 60Hz without regard to input frequency. Acceptable
range is from 40Hz to 120Hz at this setting.
*3 : A conditions to switch to bypass synchronously are as follows.
Frequency auto-detect setting is selected. Input frequency is in the synchronized range and input voltage is in the rated voltage range.

Model List
Model
Backup time 5
minutes (3U type)

Backup time 10
minutes (4U type)

A11J502WA001

A11J502WA001-4U

A11J103WA001
A11J502WA002

Input
voltage

Output
voltage

Output
capacity
(kVA)

A11J103WA001-4U

100 V
or
200 V

10

A11J502WA002-4U

200 V

Capacity expansion/
parallel redundant
operation

Vertical
mounting

Rackmounting

UL/CE certied
unit

Optional
battery (min)*5

3060180

3060180

3060180

Remark

100 V
or
100/200 V

A11J103WA002

A11J103WA002-4U

200 V

A11J502WA002Z

A11J502WA002Z-4U

200 V

A11J103WA002Z

A11J103WA002Z-4U

200 V

10

A11J153WA002Z

A11J153WA002Z-4U

200 V

15

A11J203WA002Z

A11J203WA002Z-4U

200 V

A11J502WA002DX

A11J502WA002DX-4U

200 V

100/200 V

A11J103WA002DX

A11J103WA002DX-4U

200 V

100/200 V

10

A11J153WA002DX

A11J153WA002DX-4U

200 V

100/200 V

15

A11J203WA002DX

A11J203WA002DX-4U

200 V

100/200 V

20

10

Only parallel redundant


operation is possible,
while capacity cannot be
expanded

20
With
receptacle
output

*5: The optional battery pack is used in conjunction with a UPS with a backup time of 5 minutes (3U type). When using an optional battery pack, the model number will
change. Please contact Sanyo Denki.

Specications of External Connection Terminal, Wiring Wire, etc.


Model
Backup time 5 min.

Backup time 10 min.

A11J502A002T

A11J502A002T-4U

A11J502A002N

A11J502A002N-4U

A11J103A002T
A11J502SA002

I/O connection
terminal/plug

Input wire *1

Input: M6
Output: NEMA L6-30R
8 mm2
IEC-C13 ( 2 )
Input: NEMA L6-30P
Output: NEMA L6-30R 2

NEMA L6-20R 2
Input: M6
Output: M6
NEMA L6-30R 2
NEMA L6-20R 2

A11J502SA002-4U

Output wire *1

Grounding
wire *1

Input breaker
capacity *1

8 mm2

5.5 mm2

40 A or more

30 A or more

22 mm2

22 mm2

14 mm2

80 A or more

8 mm2

8 mm2

8 mm2

40 A or more

mm2

mm2

mm2

A11J103SA002

A11J103SA002-4U

22

A11J153SA002

A11J153SA002-4U

38 mm2

38 mm2

14 mm2

120 A or more

A11J203SA002

60 mm2

60 mm2

14 mm2

160 A or more

mm2

mm2

mm2

40 A or more

A11J103SA002RM

Input: M8
Output: M8
A11J502SA002RM-4U
NEMA L6-30R 4
A11J103SA002RM-4U

22 mm2

22 mm2

14 mm2

80 A or more

A11J153SA002RM

A11J153SA002RM-4U

38 mm2

38 mm2

14 mm2

120 A or more

A11J203SA002RM

A11J203SA002RM-4U

60 mm2

60 mm2

14 mm2

160 A or more

A11J502WA001-4U

8 mm2 (200 V ) 8 mm2 ( s i ze A A ) ,


22mm2 (100 V ) 14 mm2 ( s i ze C )

8 mm2

40 A(200 V
80 A(100 V

A11J103WA001

A11J103WA001-4U

22mm2 (200 V) 14 mm2 (size AA),


38mm2 (100 V ) 38 mm2 ( s i ze C )

14 mm2

A11J502WA002

A11J502WA002-4U

8 mm2

A11J103WA002

A11J103WA002-4U

22 mm2

A11J502SA002RM

A11J502WA001

A11J203SA002-4U

I/OM8

22

14

8 mm2 ( s i ze A A ) ,
14 mm2 ( s i ze C )
14 mm2 (size AA),
38 mm2 ( s i ze C )
mm2

8 mm2

60 A or more

14 mm2

125 A or more

8
( s i ze A A ) ,
14 mm2 ( s i ze C )

mm2

40 A or more

14 mm2

80 A or more

A11J502WA002Z-4U

A11J103WA002Z

A11J103WA002Z-4U

22 mm2

14 mm2 (size AA),


38 mm2 ( s i ze C )

A11J153WA002Z

A11J153WA002Z-4U

38 mm2

38mm2 ( s i ze A A ) ,
14 mm2
22mm2x2 ( s i ze C )

125 A or more

A11J203WA002Z

A11J203WA002Z-4U

60 mm2

60mm2 ( s i ze A A ) ,
14 mm2
38mm2x2 ( s i ze C )

160 A or more

A11J502WA002DX

A11J502WA002DX-4U Input: M8

8 mm2

8 mm2

8 mm2

40 A or more

A11J103WA002DX

A11J103WA002DX-4U Output: M8

22 mm2

14 mm2

14 mm2

80 A or more

mm2

mm2

125 A or more

14 mm2

160 A or more

A11J153WA002DX

A11J153WA002DX-4U

A11J203WA002DX

A11J203WA002DX-4U

38

60 mm2

14

200 V

100 V
or
80 A(200 V 200 V
160 A(100 V

mm2

NEMA L6-30R 10
2
NEMA 5-15R-dual- 38 mm
unit2
60 mm2

200 V

80 A or more

A11J502WA002Z

Input
Output
voltage voltage

100 V
or
100 V/200 V

200 V

100 V/200
V

Transfer signal: (1) Contact signal: DSUB15 (female) xing screw M3 (2) PC interface: DSUB9 (male) xing screw #4-40UNC
Remote control: Spring clamp terminal block Applicable wires: Single wire: AWG28 to 18, twisted wire: AWG22 to 20

UL/CE certied unit


Model
Backup time 5 min.

A11J502A002T

A11J153SA002RM
A11J203SA002RM

35 A (UL489
certied unit)

35 A (UL489
certied unit)

35 A (UL489
certied unit)

35 A (UL489
certied unit)

70 A (UL489
certied unit)
100 A (UL489
certied unit)
125 A (UL489
certied unit)
35 A (UL489
certied unit)
70 A (UL489
certied unit)
100 A (UL489
certied unit)
125 A (UL489
certied unit)

70 A (UL489
certied unit)
100 A (UL489
certied unit)
125 A (UL489
certied unit)
35 A (UL489
certied unit)
70 A (UL489
certied unit)
100 A (UL489
certied unit)
125 A (UL489
certied unit)

8 mm2
(8 AWG

8 AWG

14 mm2
(6 AWG

14 mm2

14 mm2

6 AWG

6 AWG

A11J153SA002

A11J103SA002RM

5.5 mm2

Field wireless terminal


block:Applicable wire 20 to 4 AWG

A11J103SA002

A11J502SA002RM

Input breaker Output breaker


capacity *1
capacity *1

Input wire *1 Output wire *1

A11J502SA002

A11J203SA002

Grounding
wire *1

I/O connection terminal / plug

Field wireless terminal


block:Applicable wire 6 to 1/0 AWG

22 mm2
(4 AWG
50 mm2
(1 AWG
60 mm2
(1/0 AWG
14 mm2
(6 AWG
22 mm2
(4 AWG
50 mm2
(1 AWG
60 mm2
(1/0 AWG

8 mm2

10 AWG

22 mm2

14 mm2

4 AWG

6 AWG

38 mm2

22 mm2

1 AWG

4 AWG

60 mm2
1/0 AWG

38 mm2
2 AWG

14 mm2

14 mm2

6 AWG

6 AWG

22 mm2

14 mm2

4 AWG

6 AWG

38 mm2
1 AWG
60 mm2
1/0 AWG

22 mm2
4 AWG
38 mm2
2 AWG

Input
voltage

Output
voltage

200 V

200 V

Transfer signal: (1) Contact signal: DSUB15 (female) xing screw M3 (2) PC interface: DSUB9 (male) xing screw #4-40UNC
Remote control: Spring clamp terminal block Applicable wires: Single wire: AWG28 to 18, twisted wire: AWG22 to 20
*1: When planning to add one or more UPS units, use a wire size and an input breaker capacity that is applicable to the UPS capacity after one or more UPS units
are added. When using a UL/CE certied unit, use a wire size and an I/O breaker capacity that are applicable to the current UPS capacity.

External Dimensions
Backup Time 5 Minutes, Single Unit/Rack Mounting/Floor Type
Model
Dimensions
Width
Size Dipth*1
Height
Mass*3

A11J502A002T

A11J502A002N

Fig.1
435 mm (17.13 in)
700+30 mm (27.56+1.18 in)
130 mm (5.12 in)
61(26) kg [134(57) lbs]

Fig.1
435 mm (17.13 in)
700+30 mm (27.56+1.18 in)
130 mm (5.12 in)
61(26) kg [134(57) lbs]

Model
Dimensions
Width
Size Dipth*1
Height
Mass*3

A11J153SA002
Fig.5
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
671 mm (26.42 in)
223(118)kg [492(260) lbs]

A11J203SA002
A11J502WA001
A11J103WA001
A11J502WA002
Fig.6
Fig.7
Fig.8
Fig.7
435 mm (17.13 in)
435 mm (17.13 in)
435 mm (17.13 in)
435 mm (17.13 in)
700+80 mm (27.56+3.15 in) 700+80 mm (27.56+3.15 in) 700+80 mm (27.56+3.15 in) 700+80 mm (27.56+3.15 in)
803 mm (31.61 in)
541 mm (21.30 in)
673 mm (26.50 in)
541 mm (21.30 in)
284(144) kg [626(317) lbs] 211(176) kg [465(388) lbs] 322(252)kg[710(556) lbs]
181(146) kg [399(322) lbs]

Model
Dimensions
Width
Size Dipth*1
Height
Mass*3

A11J103WA002

A11J502WA002Z
Fig.9
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
718 mm (28.27 in)
266(231) kg [586(509) lbs]

A11J103WA002Z
Fig.10
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
850 mm (33.46 in)
327(257) kg [721(567) lbs]

A11J153WA002Z
Fig.11
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
981 mm (38.62 in)
388(283) kg [855(624) lbs]

A11J103WA002DX
Fig.10
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
850 mm (33.46 in)
332(262)kg [732(578) lbs]

A11J153WA002DX
Fig.11
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
981 mm (38.62 in)
393(288)kg [866(635) lbs]

A11J203WA002DX
Fig.12
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
1113 mm (43.82 in)
454(314)kg [1001(692) lbs]

Model
Dimensions
Width
Size Dipth*1
Height
Mass*3

Fig.8
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
673 mm (26.50 in)
272(202)kg [600(445) lbs]
A11J502WA002DX

Fig.9
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
718 mm (28.27 in)
271(236)kg [597(520) lbs]

A11J103A002T
Fig.2
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
262 mm (10.30 in)
125(55) kg [276(121) lbs]

A11J502SA002
Fig.3
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
408 mm (16.06 in)
101(66) kg [223(146) lbs]

A11J103SA002
Fig.4
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
540 mm (21.26 in)
162(92) kg [357(203) lbs]

A11J203WA002Z
Fig.12
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
1113 mm (43.82 in)
449(309) kg [990(681) lbs]

Backup Time 5 Minutes, Rack Mounting


A11J153SA002RM
Fig.13 3unit*2+Fig.14

A11J203SA002RM
Fig.13 4unit*2+Fig.14

435 mm (17.13 in)


700+80 mm (27.56+3.15 in)
436 mm (17.17 in)
155 kg (342 lbs)

435 mm (17.13 in)


700+80 mm (27.56+3.15 in)
566 mm (22.28 in)
216 kg (476 lbs)

435 mm (17.13 in)


700+80 mm (27.56+3.15 in)
696 mm (27.40 in)
277 kg (611 lbs)

ALARM

ALARM

OUTPUT

MAIN
MCCB

MAIN
MCCB

480 (18.90)

731 (28.78)

190 (7.48)

Fig.3

ALARM

OUTPUT
ALARM

ALARM

ALARM

322 (12.66)

OUTPUT

INPUT

OUTPUT

731 (28.78)

INPUT

MAIN
MCCB

OUTPUT

700 (27.56)

INPUT

435 (17.13)

700 (27.56)

MAIN
MCCB

480 (18.90)

Fig.4

Fig.5

Fig.6
435 (17.13)

435 (17.13)

ALARM

OUTPUT
ALARM

MAIN
MCCB

Fig.7

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

Fig.8

INPUT
OUTPUT
ALARM

ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

10

Fig.10

435 (17.1

435 (17.13)

435 (17.13)
435 (17.13)

MAIN
MCCB

ALARM

OUTPUT

Fig.9

ALARM

OUTPUT

INPUT

1.6

OUTPUT

OUTPUT

INPUT

MAIN
MCCB

671 (26.42)

INPUT

700 (27.56)

INPUT

540 (21.26)

408 (16.06)

700 (27.56)

700 (27.56)
INPUT

803 (31.61)

435 (17.13)
435 (17.13)

700 (27.56)

435 (17.13)

700 (27.56)

700 (27.56)

700 (27.56)
INPUT
OUTPUT
ALARM

700 (27.56)

MAIN
MCCB

INPUT

INPUT

OUTPUT

OUTPUT
ALARM

ALARM

981 (38.62)

OUTPUT

262 (10.30)
262 (10.30)

130 (5.12)

700 (27.56)

INPUT

2
Vertically
Mounting

700 (27.56)

443 (17.44)
435 (17.13)

INPUT

130 (5.12)
435 (17.13)

Fig.22Rack Mounting

Vertically
1 Mounting

INPUT

Rack
Fig.1
1 Mounting

MAIN
MCCB

Unit: mm (inch)

*1: UPS unit + cable cover/terminal block


*2: The second and the following UPS
units are not equipped with an LCD
display panel.
*3: Figures in parentheses indicate the
weights of the 30-min, 60-min, and 180min UPS units (without a battery pack).

MAIN
MCCB

Fig.13+Fig.14
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
306 mm (12.05 in)
94 kg (207 lbs)

A11J103SA002RM
Fig.13 2unit*2+Fig.14

435 (17.13)

A11J502SA002RM

443 (17.44)

Model
Dimensions
Width
Size Dipth*1
Height
Mass*3

INPUT
OUTPUT

850 (33.46)

ALARM

MAIN
MCCB

541 (21.30)

ALARM

MAIN
MCCB

Fig.11

718 (28.27)

OUTPUT

673 (26.50)

MAIN
MCCB

INPUT

INPUT
OUTPUT
ALARM

MAIN
MCCB

Fig.12

Fig.13
13

MAIN
MCCB

Fig.1414

435 (17.13)
435 (17.13) 700 (27.56)
700 (27.56)

435 (17.13)
435 (17.13) 700 (27.56)
700 (27.56)

43

INPUT
OUTPUT
ALARM
INPUT
OUTPUT
ALARM

INPUT

OUTPUT

OUTPUT

ALARM

ALARM

MAIN
MCCB

MAIN
MCCB

MAIN
MCCB

MAIN
MCCB

INPUT

OUTPUT

OUTPUT

ALARM

ALARM
INPUT

INPUT

OUTPUT

OUTPUT

OUTPUT
ALARM
INPUT
OUTPUT

981 (38.62)

ALARM

MAIN
MCCB

ALARM

1113 (43.82)

MAIN
MCCB

INPUT

MAIN
MCCB

1113 (43.82)

ALARM

MAIN
MCCB

MAIN
MCCB

MAIN
MCCB

INPUT
OUTPUT
ALARM
INPUT
OUTPUT
ALARM

MAIN
MCCB

MAIN
MCCB

130 (5.12)

INPUT

700 (27.56)

INPUT
OUTPUT
ALARM

MAIN
MCCB

480 (18.90)

731 (28.78)

175 (6.89)

ALARM
INPUT

981 (38.62)

435 (17.13)

OUTPUT

ALARM

435 (17.13)

700 (27.56)

480 (18.90)

731 (28.78)

354
309

MAIN
MCCB

INPUT

OUTPUT

MAIN
MCCB

INPUT

External Dimensions
Backup Time 10 Minutes, Single Unit/Rack Mounting/Floor Type
Model
Dimensions
Width
Size Dipth*1
Height
Mass

Fig.18
435 mm (17.13 in)
700+30 mm (27.56+1.18 in)
175 mm (6.89 in)
80 kg (176 lbs)

A11J502A002N-4U
Fig.18
435 mm (17.13 in)
700+30 mm (27.56+1.18 in)
175 mm (6.89 in)
80 kg (176 lbs)

A11J502SA002-4U
Fig.19
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
453 mm (17.83 in)
120 kg (265 lbs)

A11J103SA002-4U
Fig.20
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
629 mm (24.76 in)
200 kg (441 lbs)

A11J153SA002-4U
Fig.21
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
805 mm (31.69 in)
280 kg (617 lbs)

Model

A11J203SA002-4U

A11J502WA001-4U

A11J103WA001-4U

A11J502WA002-4U

A11J103WA002-4U

435 (17.13)

A11J502WA002Z-4U
700 (27.56)
A11J502WA002DX-4U

435 (17.13)

Model

A11J103WA002Z-4U
A11J103WA002DX-4U
INPUT

OUTPUT
ALARM

MAIN
MCCB

OUTPUT

ALARM

ALARM

763 (30.04)

939 (36.97)

INPUT
INPUT

OUTPUT

Dimensions
Width
Size Dipth*1
Height
Mass

Fig.25
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
763 mm (30.04 in)
290 kg (639 lbs)

INPUT

OUTPUT
ALARM

MAIN
MCCB

700 (27.56)

INPUT

MAIN
MCCB

Fig.24
Fig.23
Fig.24
435 mm (17.13 in)
435 mm (17.13 in)
435 mm (17.13 in)

in)
700+80 mm
(27.56+3.15
700+80 mm (27.56+3.15
in) 700+80 mm (27.56+3.15 in)
435 (17.13)
700 (27.56)
762 mm (30.00 in)
586 mm (23.07 in)
762 mm (30.00
in)
435
(17.13)
700
(27.56)
360 kg (794 lbs)
200 kg (441 lbs)
310 kg (683 lbs)

Fig.26
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
939 mm (36.97 in)
370 kg (816 lbs)
MAIN
MAIN
MCCB
MCCB

INPUT

INPUT

OUTPUT

OUTPUT

ALARM

ALARM

A11J153WA002Z-4U
A11J153WA002DX-4U

A11J203WA002Z-4U
A11J203WA002DX-4U

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

Fig.27
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
1115 mm (43.90 in)
450 kg (992 lbs)

MAIN
MCCB

1291 (50.83)

Dimensions Fig.22
Fig.23
W2

Width 435 mm (17.13 in)


435 mm (17.13 in)

mm (27.56+3.15 in)
700+80
Size
Dipth*1 700+80 mm (27.56+3.15 in)
Height 981 mm (38.62 in)
586 mm (23.07 in)
Mass
360 kg (794 lbs)
230 kg (507 lbs)

1115 (43.90)

A11J502A002T-4U

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

Fig.28
435 mm (17.13 in)
700+80 mm (27.56+3.15 in)
1291 mm (50.83 in)
530 kg (1168 lbs)

MAIN
MCCB

MAIN
MCCB

Backup Time 5 Minutes, Rack Mounting


Model
A11J502SA002RM-4U
A11J103SA002RM-4U

Dimensions
Fig.17+Fig.14
Fig.17
2unit*2+Fig.14
Width
(W)
435
mm
(17.13
in)
435
mm
(17.13 in)

Size
Dipth(D)*1 700+80 mm (27.56+3.15 in) 700+80 mm (27.56+3.15 in)
(mm)
Height (H) 351 mm (13.82 in)
525 mm (20.67
in)
435 (17.13)
700 (27.56)
Mass
113 kg (249 lbs)
193 kg (425 lbs)
435 (kg)
(17.13)
700 (27.56)

*1: UPS unit + cable cover/terminal


block
*2: The second and the following
UPS units are not equipped
with an LCD display panel.

A11J153SA002RM-4U
A11J203SA002RM-4U
Fig.17 3unit*2+Fig.14 Fig.17 4unit*2+Fig.14

435 mm (17.13 in)


700+80 mm (27.56+3.15 in)
700 mm (27.56 in)
273 kg (602 lbs)

435 mm (17.13 in)


700+80 mm (27.56+3.15 in)
874 mm (34.41 in)
353 kg (778 lbs)

INPUT

OUTPUT
ALARM

INPUT
OUTPUT
ALARM

731 (28.78)

INPUT
OUTPUT
ALARM

MAIN
MCCB

480 (18.90)

435 (17.13)

435 (17.13)
700 (27.56)

731 (28.78)
700 (27.56)

INPUT
OUTPUT
ALARM

OUTPUT

763 (30.04)

MAIN
MCCB

435 (17.13)

INPUT
INPUT
OUTPUT

MAIN
MAIN
MCCB
MCCB

MAIN
MCCB

Fig.23

OUTPUT

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

480 (18.90)
435 (17.13)

731 (28.78)
700 (27.56)

435 (17.13)

700 (27.56)

ALARM

234 (9.21)
INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

Fig.22

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

435 (17.13)

700 (27.56)

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

435 (17.13)

700 (27.56)

MAIN
MCCB

INPUT
OUTPUT
ALARM

INPUT

INPUT

OUTPUT

OUTPUT

ALARM

ALARM

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

MAIN
MCCB

Fig.24
435 (17.13)

435 (17.13)

MAIN
MCCB

MAIN
MCCB

INPUT

629 (24.76)

453 (17.83)

ALARM

ALARM

700 (27.56)

ALARM

OUTPUT

OUTPUT

700 (27.56)

MAIN
MCCB

435 (17.13)

700 (27.56)

INPUT

700 (27.56)
INPUT

Fig.21

MAIN
MCCB

ALARM

939 (36.97)

ALARM

1115 (43.90)

Fig.20

INPUT

435 (17.13)

805 (31.69)

Fig.19

175 (6.89)

981 (38.62)

480 (18.90)

700
700 (27.56)

OUTPUT

435
W2

435 (17.13)
700 (27.56)
435 (17.13)

Vertically Mounting

700

INPUT

435

MAIN
MCCB

Fig.18 Rack Mounting

435 (17.13)

Fig.17

1291 (50.83)

MAIN
MCCB

443 (17.44)

MAIN
MCCB

175 (6.89)
354
309

175 (6.89)

586 (23.07)

ALARM

487

Unit: mm (inch)
14
Fig.14
OUTPUT

175 (6.89)531

762 (30.00)

MAIN
MCCB

INPUT

700 (27.56)

700 (27.56)
INPUT
OUTPUT
ALARM

762 (30.00)

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

W2

Fig.26

Fig.25

435 (17.13)

435 (17.13)
435 (17.13)

INPUT
OUTPUT
ALARM

MAIN
MCCB

OUTPUT
ALARM

763 (30.04)

939 (36.97)

INPUT
INPUT

MAIN
MAIN
MCCB
MCCB

435 (17.13)

700 (27.56)

INPUT
OUTPUT

MAIN
MCCB

629 (24.76)

453 (17.83)

10

ALARM

INPUT
OUTPUT
ALARM

435 (17.13)

MAIN
MCCB

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

700 (27.56)

INPUT

OUTPUT

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

INPUT
OUTPUT
ALARM

435 (17.13)

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

OUTPUT

ALARM

INPUT

OUTPUT

INPUT

OUTPUT

ALARM

700 (27.56)

INPUT

MAIN
MCCB

MAIN
MCCB

MAIN
MCCB

ALARM

OUTPUT

ALARM

ALARM

ALARM

INPUT

OUTPUT

OUTPUT

OUTPUT

700 (27.56)

INPUT

INPUT

INPUT

435 (17.13)

700 (27.56)

700 (27.56)

MAIN
MCCB

700 (27.56)

MAIN
MCCB

Fig.28

1291 (50.83)

435 (17.13)

Fig.27

ALARM

981 (38.62)

586 (23.07)

ALARM

1115 (43.90)

OUTPUT

805 (31.69)

INPUT

MAIN
MCCB

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

INPUT
OUTPUT
ALARM

MAIN
MCCB

700 (27.56)

Options
Battery BoxDimensions, Mass (Rackmounting exclusive use)
Dimensions

Size
Width

Dipth

Capacity of Optional battery composition


battery
A11J502
A11J103
A11J153
A11J203
(Ahcell) 15min. 25min. 35min. 45min. 15min. 25min. 35min. 45min. 15min. 25min. 35min. 45min. 15min. 25min. 35min. 45min.

Mass

Height

Fig.1

435 mm 700+80 mm 130 mm 49 kg


480
17.13 in 27.56+3.15 in 5.12 in
108 lbs

1unit -

Fig.1

435 mm 700+80 mm 130 mm 84 kg


960
17.13 in 27.56+3.15 in 5.12 in
185 lbs

1unit -

2unit -

1unit -

1unit 1unit 2unit 1unit 2unit 2unit -

1unit 3unit -

2unit -

Battery BoardDimensions, Mass


Mass

Capacity of Optional battery composition


battery
A11J502
A11J103
A11J153
A11J203
(Ahcell) 30min. 60min. 180min. 30min. 60min. 180min. 30min. 60min. 180min. 30min. 60min. 180min.

700+12 mm 544 mm
27.56+0.47 in 21.42 in

215 kg
474 lbs

2688

1unit

1unit

440 mm
17.32 in

700+12 mm 988 mm
27.56+0.47 in 38.90 in

415 kg
915 lbs

5376

1unit

1unit

2unit

Fig.4

440 mm
17.32 in

870+12 mm 544 mm
34.25+0.47 in 21.42 in

320 kg
705 lbs

4224

1unit

1unit

Fig.5

440 mm
17.32 in

870+12 mm 988 mm
34.25+0.47 in 38.90 in

620 kg
8448
1367 lbs

1unit

1unit

2unit

1unit

3unit

2unit

4unit

Dimensions

Size
Width

Dipth

Fig.2

440 mm
17.32 in

Fig.3

Height

Unit: mm (inch)

Fig.1

Fig.2
440 (17.32)

440 (17.32)

700 (27.56)
544 (21.42)

544 (21.42)

Fig.3

Fig.5
440 (17.32)

700 (27.56)

Model No.RM028

Model No.RMA11JWA00

654 to 798 (25.75 to 31.42)

48 (1.89)

Rack mounting dimension


A set of left and right rails
The figure shows the left rail

654 to 798 (25.75 to 31.42)

Rack mounting dimension

175 (6.89)

135 (5.31)

180 (7.09)

480 (18.90)

Rack mounting dimension


688 to 798 (27.09 to 31.42)

Model No.RM030
88 (3.46)

988 (38.90)

Rack Support Rails


Dimensions
Model No.RM027

870 (34.25)

988 (38.90)

440 (17.32)

48 (1.89)

870 (34.25)

700 (27.56)

130 (5.12)

435 (17.13)

Fig.4

48 (1.89)

555 to 913 (21.85 to 35.94)

Rack mounting dimension


A set of left and right rails
The figure shows the left rail

A set of left and right rails


The figure shows the left rail

Transformer Box
This is a rack-mounting transformer unit that can be mounted in a 19-inch rack and that can convert the voltage from 200 V to 100 V.
A transformer, a breaker, and a receptacle are integrated into the unit to save space so that the 2U size can be achieved.

Dimensions
Model No.: TRA11J502A00NRM

Model No.: TRA11J502A00TRM


577 (22.72)

480 (18.90)

607 (23.90)

435 (17.13)

577 (22.72)

480 (18.90)

607 (23.90)

86 (3.39)

86 (3.39)

435 (17.13)

I/O terminal block: M6, output receptacle: 5-15R-dual-unit x 4 circuits


Mass: Approx. 42 kg

Input plug: L6-30P, output terminal block: M6, output receptacle: 5-15R-dual-unit x 4 circuits
Mass: Approx. 42 kg

* The battery box, battery board, and transformer box are not UL/CE certified.

11

Eco Products
Sanyo Denki's ECO PRODUCTS are designed with the concept of lessening impact on the environment in the process from product development to waste.The product units
and packaging materials are designed for reduced environmental impact.We have established our own assessment criteria on the environmental impacts applicable to all
processes,ranging from design to manufacture.Those products that satisfy the criteria are accredited as ECO PRODUCTS.

Notes when investigating use of this product in your applications


Before starting installation, assembling and use, read the Operation
Manual carefully and use the product correctly in your applications.
When you are going to use this product in the following application, the
special considerations are required for operation, running, maintenance
and control. Be sure to consult with our company as a part of your
investigations.
(a) Medical equipment and other equipment that are related directly to
human life.
(b) Train or elevator that can give injury to human body.
(c) Socially and publicly important computer systems.

(d) And other equipment that are related to safety of human life and that
can affect severe effects on maintenance of public functions.
For the applications that undergo vibration such as vehicles, ships and
transportation facilities, please consult with our company.
Never modify this product or give additional processing to this product.
For the installation andmaintenance work, please consult with our
company or with specialized company.
For any inquiry or consultation, please contact our sales representative.

http://www.sanyodenki.com
1-15-1, Kita-Otsuka, Toshima-ku, Tokyo 170-8451, Japan

Phone: +81 3 3917 5157

468 Amapola Avenue Torrance, CA 90501 U.S.A.

Phone: +1 310 783 5400

P.A. Paris Nord ll 48 Alle des Erables-VILLEPINTE BP.57286 F-95958 ROISSY CDG Cedex France

Phone: +33 1 48 63 26 61

Frankfurter Strasse 63-69 65760 Eschborn Germany

Phone: +49 6196 76113 0

9F 5-2, Sunwha-dong Jung-gu Seoul, 100-130, Korea

Phone: +82 2 773 5623

Rm2108-2109, Bldg A, Far East International Plaza, No.319, Xianxia Rd., Shanghai, 200051, China

Phone: +86 21 6235 1107

Room 1208, 12F, No.96 Chung Shan N, Rd., Sec.2, Taipei 104, Taiwan, R.O.C.

Phone: +886 2 2511 3938

Room 2305, 23/F, South Tower, Concordia Plaza, 1 Science Museum Rd., TST East, Kowloon, Hong Kong

Phone: +852 2312 6250

10 Hoe Chiang Road #14-03A/04 Keppel Towers Singapore 089315

Phone: +65 6223 1071

The names of companies and/or their products specied in this catalogue are the trade names, and/or trademarks and/or registered trademarks of such respective companies.
*Remarks : Specications Are SubjectTo Change Without Notice.
CATALOG No.953-1 10.9

Você também pode gostar