Você está na página 1de 4

GL80AA.

02
PRODUCT SPECIFICATION
OPERATION:
Application:
Refrigerant:
Operation:
Cooling:

L.B.P.
R134a

Max. Ambient Temp:


(1) Max. Steady Discharge Temp:
(1,2) Max. Peak Discharge Temp:
Max. Steady Condensing Temp:
(2) Max. Peak Condensing Temp:
Max. Winding Temp:

Capillary
Static

Max. Impurities:
Max. Total Compressor Water Content:

43C
120C
135C
60C
70C
130C
30 mg
100 mg

COMPRESSOR:
Displacement:
Bore:
Stroke:

(3) Net Wt:


Case Size:
Oil Charge:

7.39 cc
24.29 mm
15.94 mm

Oil Type:
(4) Viscosity:
Suction Muffler:

9.0 kg
2 (h = 175 mm)
210 cc

Ester
15 cSt
Semi-direct

ELECTRICAL:
Power Supply:
Voltage Limits:
Frequency:
Phase:

220 - 240V
187 - 264V
50 Hz
1 ph

Motor Type:
Locked Rotor Current:

Main Winding Resistance at 25C:


Start Winding Resistance at 25C:

RSIR / RSCR *
12.0 / 7.1 A**

11.7
18,8

With Optional Run Capacitor

** Maximum current / Measured after 4 seconds


For rated performance,
(1) Measured 5cm. from the shell with insulated thermocouples

the suction line must be connected to the stub

(2) For transient conditions during 'Pull Down'

marked 'AS' on the attached drawing.

(3) Net weight is with oil but without electrics


(4) Measured at 40C

AE 0218.5

Aug '03

Page 1

Electrolux Compressors reserves the right to change the data without prior notice

GL80AA.02
PRODUCT SPECIFICATION
ELECTRICAL COMPONENTS:
ZEM Starting Device:
(1) ZEM Starting Device:
ZEM PTC Resistance:
Run Capacitor:

PTC- 8100
PTC - 7100D6

UH Starting Device:
UH PTC Resistance:
Alt. UH Starting Device:
ECC Starting Device:

14

PTC- 3003-x

14

PTC- 3001-x
K 100-xx

4.0 F
-x PTC code for different contact versions
-xx Protector short code

PROTECTORS:
PROTECTORS
Type
Open C
Close C
U.T.C
Time Check Current

Max. Current
Code (if any)
Alt. protectors:

BDG
AE 15 BW x
125 - 135 C
71 - 53 C
1.95 A 70 C
8.20 A
16.0 A

Electrica
T 0502 / kk
125 - 135 C
70 - 55 C
2.37 A 70 C
9.00 A
17.0 A

FQ

CE

AF 15 BW x
D6

BDG 'x' Codes: 6 for terminal boards Mod.89,90


8 for terminal board Mod.91
4 for UH protector with 6.3mm fast-on
5 for UH protector with M3.5 screw
Electrica 'kk' Codes: 05 for terminal boards Mod.89,90
07 for terminal board Mod.91
C5 for UH protector with M3.5 screw
C6 for UH protector with 6.3mm fast-on

Protectors with M 3.5 screws can be used on UH electric housings type SP-1454 (with connection board)
and SP-1821 (without connection board).
See drawings ELECTRICAL ASSEMBLY (FOR UH) number FTC15;16;17;18.
protectors with 6.3mm fast-on can only be used on UH electric housing type SP-1821 (without connection board).

AE 0218.5

Aug '03

Page 2

Electrolux Compressors reserves the right to change the data without prior notice

GL80AA.02

PROVISIONAL

PRODUCT SPECIFICATION
PERFORMANCE:
Amps

220V 50Hz Without run capacitor

(Graphs are at ASHRAE conditions)

1.50
1.30
1.10
0.90
0.70

Input
Watts

0.50
240
190
140
90

C.o.P.

40
2.00
1.80
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20

0.00
Capacity 400
kcal/h
350
300
250
200
Test Conditions:
Condensing Temp:
Liquid Temp:
Gas Return Temp:
Ambient Temp:

150
100

ASHRAE
55C
32C
32C
32C

CECOMAF
55C
55C
32C
32C

50
0
-35

-30

-25

-20
-15
Evaporating Temperature (C)

-10

-5

Evaporating Temperature C

-30

-25

-23.3

-20

-15

-10

ASHRAE:

Capacity
C.o.P.

Kcal/h
W/W

109
1.02

153
1.19

170
1.25

206
1.37

266
1.55

337
1.73

CECOMAF:

Capacity
C.o.P.

W
W/W

104
0.84

145
0.97

195
1.11

252
1.26

319
1.41

W
A

124
1.06

150
1.12

175
1.19

200
1.27

227
1.37

Input Power
Current

AE 0218.5

Aug '03

Page 3

158
1.14

Electrolux Compressors reserves the right to change the data without prior notice

GL80AA.02
PRODUCT SPECIFICATION
Mounting Accessories

Circuit Diagram for Mod.90 Terminal Board


N

Appliance,
Lights etc.
2

Motor
Protector

Thermostat
N

PTC
Relay

y
Wire Connection

Run Capacitor
where applicable

Fast-on
connectors

x
x = 26mm or 28.5mm
y = 9mm or 10.3mm
Other sizes available
1. Rubber grommet
2. Sleeve
3. Washer
4. Steel pin
5. Clip

Circuit Diagram for U.H. Terminal Board


N

Thermostat

Motor
Protector

PTC
Relay
Run Capacitor
where applicable

Appliance,
Lights etc.

Wire Connection

Recommended Transport
Positions when fitted into
appliances

Circuit Diagram for ECC Terminal Board Frontal Version


Appliance,
Lights etc.

Upright

Motor
Protector

Thermostat
1

Electrics Up
E

L
PTC

Tubes Down

5th
Optional

S
NL
Run Capacitor
where applicable

Compressor Label
PRODUCTION
DATE CODE
ELECTRICAL
CHARACTERISTICS

LOGO
MODEL
B
VARIANT CODE
REFRIGERANT

APPROVALS
MANUFACTURER
VERSION CODE
CHECK DIGIT

BAR CODE
SERIAL NUMBER

AE 0218.5

Aug '03

Page 4

Electrolux Compressors reserves the right to change the data without prior notice

Você também pode gostar