AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches
Software Release Notes
Please read this document before you begin to use the AT-9000 Series AlliedWare Plus
Version 2.4.1.7 CLI software. The document has the following sections:
Supported Platforms
Version 2.4.1.7 of the AlliedWare Plus CLI Management Software is supported on these
switches:
AT-9000/12POE
AT-9000/28
AT-9000/28POE
AT-9000/28SP
AT-9000/28SP-E
AT-9000/52
AT-SPEX
AT-SPSX
AT-SPFX/2
AT-SPFX/15
AT-SPLX10
AT-SPLX40
AT-SPZX/80
AT-SPBD10-13
AT-SPBD10-14
AT-SPFXBD-LC-13
AT-SPFXBD-LC-15
PN 613-002262 Rev B
Product Documentation
Refer to the Allied Telesis web site at www.alliedtelesis.com/support for the latest installation
and user guides.
Operational Notes
The AT-9000 Series switches behave in the following manner:
SFP Configuration - The speed of the AT-SPFX/2 and AT-SPFX/15 modules must be
manually set to 100Mbps with the SPEED command. The following example of the
command configures the speed of the AT-SPFX/2 or AT-SPFX/15 module in slot 1 of an
AT-9000/28SP Switch:
awplus> enable
awplus# configure terminal
awplus(config)# interface port1.0.1
awplus(config-if)# speed 100
Web Interface - You cannot use the web browser interface to configure the following
features:
Access control lists
Enhanced stacking
Quality of Service
SNMP
Voice VLANs
Use the command line interface to configure these features.
New Features
Version 2.4.1.7
None
Version 2.4.1.6
None
Version 2.4.1.5
None
Version 2.4.1.4
None
Version 2.4.1.3
When IGMP snooping is enabled, multicast UDP packets will not be flooded. If UDP
multicast traffic flooding is required, IGMP snooping must be disabled.
PN 613-002262 Rev B
An ACL applied on a port now filters traffic going to the switch management. Previously,
ACLs only filtered through data traffic.
Version 2.4.1.2
None
Version 2.4.1.1
None
Resolved Issues
Version 2.4.1.7
Temperature that triggers the fan to spin has been lowered on models with a fan module.
Version 2.4.1.6
On the AT-9000/28SP v2, after re-inserting an AT-SPSX SFP module, the port does not
link up. This issue is fixed.
On the AT-9000/28SP v2, the AT-SPSX Rev E module on a base port does not link up
after a reboot. This issue is fixed.
Version 2.4.1.5
Version 2.4.1.4
AT-9000/28SP v2 web GUI did not show Spanning Tree status. This issue has been
resolved.
A case where MAC authentication with multiple supplicants did not work. This issue has
been resolved.
Web GUI did not accept username with a dot character in it. This issue has been
resolved.
Version 2.4.1.3
Version 2.4.1.2
A case where an ARP entry might not have appeared in ARP table but communication
works. This issue is resolved.
Power-inline max 15440 was not written to running-config. This issue is resolved.
PN 613-002262 Rev B
Version 2.4.1.1
24/7 Online Support - Enter our interactive support center to search for
answers to your questions in our knowledge database, check support tickets,
learn about RMAs, and contact Allied Telesis technical experts.
USA and EMEA phone support - Select the phone number that best fits your
location and customer type.
Software Updates - Download the latest software releases for your product.
PN 613-002262 Rev B