14'-8"

3'

6'-2"

NOTES:

5'-6"

1. INSTALL 3 5 /8'' (20 GA) METAL STUD BRACING RUNNING


DIAGONAL FROM BOTH SIDES OF EVERY OTHER STUD TO
BOTTOM TRACK. SEE SKETCH BELOW:

MTL ANGLE AT EACH BRACE


ATTACHED TO DECK ABOVE WITH
1/2'' SELF-TAPPING SCREWS

NEW

1''

ACOUSTICAL BATT
INSULATION

CONTINUES METAL STUD TRACK


5/8'' GYPSUM BOARD ON EACH SIDE OF 3
5/8'' METAL STUDS AT 16 O.C.
CONT. METAL STUD TRACK FASTENED
TO FLOOR SLAB WITH 1 1/4''
CONCRETE SCREWS AT 16'' O.C.
FASTEN METAL STUDS ONTO BOTTOM AND
TOP TRACK WITH (2) 1 /2'' SELF-TAPPING
SCREWS ON EACH SIDE OF THE TRACK.

135''

MTL ANGLE AT EACH


BRACE FASTENED
TO MTL STUD
TRACK WITH 1/2''
SELF-TAPPING
SCREWS

11'-3"

3 5/8'' MTL STUD BRACE @ 48'' O.C.


ATTACHED TO MTL ANGLES WITH 1/2''
SELF-TAPPING SCREWS
EXISTING CEILING

FE

11'-3"

4"

32''

131''

5''

3. INSTALL DOUBLE STUDS AT ALL WALL CORNERS.


9''

4''

4"

EXISTING CONCRETE SLAB

2. INSTALL WIDE (6'' MIN.) DIAGONAL 20 GA FLAT METAL


STRAPS RUNNING FROM BOTTOM TO TOP TRACK ON EACH SIDE
OF PARTITION. FASTEN THE STRAPS TO EACH STUD AND
BOTTOM & TOP TRACKS WITH SCREWS AS REQUIRED.

NEW

32''

TYP. FULL HEIGHT


PARTITION DETAIL

4. USE FASTENERS RECOMMENDED BY STUD MANUFACTURER.

4"

10'-1"

SCALE 1''=1'-0''

121''

EXISTING SUSPENDED CEILING ABOVE

4''

42''

4''

122''

4''

CORNER BEAD (TYP.)


93''

LIFE SAFETY NOTES:

5/8'' GYPSUM BOARD ON EACH SIDE OF


3 5/8'' (20 GA) METAL STUDS AT 16 O.C.

4''

9'-0''

1. ALL WORK AND MATERIALS SHALL CONFORM TO


THE 2010 FBC, EXISTING BUILDING AND ALL OTHER
APPLICABLE CODES AND ORDINANCES.

20 GA METAL STRUD TRACK

4"

7'-6'' OR 3'-0''
SEE FLOOR PLAN

SD

4"

4"

ALTERNATE BRACE ORIENTION


WHERE POSSIBLE
METAL DECK ABOVE

32''

2. THE PROJECT TOTAL FLOOR AREA: 806,7 S.F.


3. BUSINESS TYPE: TATTOO SHOP

TYP. PARTIAL HEIGHT


PARTITION DETAIL

4''

THE TATTOO SHOP SHALL BE CLASSIFIED AS A


BUSINESS OCCUPANCY.
-1150 SF/100 GROOS=12 PERSONS

SCALE 1''=1'-0''
32''

4"

5. TRAVEL DISTANCE; PER 2010 FBC TABLE 1016.1;


DISTANCE TO EXIT IN BUSINESS OCCUPANCY WITHOUT
SPRINKLER SYSTEM
-PERMITTED 200 FT
-PROVIDED 61 FT

FASTEN METAL STUDS ONTO FLOOR TRACK


WITH (2) SCREWS ON EACH SIDE OF THE
TRACK.
EXISTING FLOOR SLAB

35'-9"

93''

55'

121''

55'
10'-1"

4. OCCUPANCY PER 2010 FBC, SECTION 304 AND


TABLE 1004.1.1;

20 GA METAL STUD TRACK GLUED AND


FASTENED TO FLOOR SLAB AT 12'' 0.C.

1. ALL WORK AND MATERIALS SHALL CONFORM TO


THE 2010 FBC, EXISTING BUILDING AND ALL OTHER
APPLICABLE CODES AND ORDINANCES.

88''

6. PLUMBING FIXTURES PER 2010 FBC-PLUMBING


TABLE 403.1;
-REQUIRED
WATER CLOSET: MALE/ FEMALE; 1 PER 25 FOR THE
FIRST 50 AND 1 PER 50 FOR THE REMAINDER
EXCEEDING 50.

121''

10'-1"

PROJECT GENERAL NOTES:

122''

0"

4''

2. THE PROJECT CLASSIFICATION IS ALTERATION


LEVEL 2.
3. THE PROJECT WORK AREA IS 806,7 S.F.
4. GENERAL SCOPE OF WORK: TATTOO SHOP
- RENOVATION & ENLARGEMENT OF ACCESSIBLE
RESTROOM.
- RELOCATION OF ELECTRICAL PANEL
- INSTALLATION OF TWO NEW SINKS
- INSTALLATION OF NEW TANKLESS WATER HEATER
- INSTALLATION OF NEW 3FT HIGH KNEW WALLS
AND PARTIAL HEIGHT PARTITIONS (7'-6'' HIGH)

4''

56''

4''

4"
6'' 30''

24''

6. WALL AND FLOOR FINISHES PER OWNER (SHALL


COMPLY WITH FBC 2010).

4"

44''

5. ALL NEW PLUMBING FIXTURES SHALL BE


COMPLIANT WITH THE 2010 FBC: PLUMBING

6'-8"

80''

-PROVIDED
WATER CLOSET: 1 AS REQUIRED.
LAVATORIES: 1 AS REQUIRED.

138''

11'-6"

DRINKING FOUNTAIN: NOT REQUIRED FOR OCCUPANT


LOAD OF 15 OR FEWER.

4''

54''

LAVATORIES: 1 PER 40 FOR THE FIRST 80 AND 1


PER 80 FOR THE REMAINDER EXCEEDING 80

4"

7.ALL EXISTING HVAC SYSTEM TO REMAIN.

4"

403.2 SEPARATE FACILITIES EXCEPTIONS:


SEPARATE FACILITIES SHALL NOT BE REQUIRED IN
BUSINESS AND MERCANTILE OCCUPANCIES WITH A
TOTAL FLOOR AREA OF 3,OOO SF OR LESS.

4" 3'-8"

4"

4'-8"
14'-8"

4"

5'

8.ALL EXISTING CEILING TILES, GRID & LIGHTS TO


REMAIN.

4"

9. FIELD VERIFY ALL DIMENSIONS.

LIFE SAFETY PLAN


SCALE 1/4''=1'-0''

FLOOR PLAN
SCALE 1/4''=1'-0''

LEGEND:
NEW CEILING MOUNTED
DIRECTIONAL EMERGENCY EXIT SIGN
EXISTING EMERGENCY EXIT SIGN/LIGHT

PLAN NOTES:
1

INSTALL NEW VANITY WITH SINK AND FAUCET.

EXISITING WALL TO REMAIN

INSTALL NEW FULL HEIGHT PARTITION (1/2'' GYPSUM BOARD


ON EACH SIDE OF 6'' METAL STUDS AT 16'' O.C.). USE
WATER - RESISTANT GYP. BOARD ON BATHROOM SIDE.

NEW FULL HEIGHT PARTITION

NEW

NEW EMERGENCY EXIT SIGN/LIGHT

FE

SD

NEW FIRE EXTINGUISHER

INSTALL NEW PARTIAL HEIGHT (7'-6'' H.) PARTITION (5/8'' GYP, BOARD
ON EACH SIDE OF 3 5/8'' METAL STUDS AT 16'' O.C.). SEE TYP. DETAIL.

INSTALL NEW KNEE WALL, 3'-0'' HIGH (5/8'' GYP, BOARD


ON EACH SIDE OF 3 5/8'' METAL STUDS AT 16'' O.C.). SEE TYP. DETAIL.

NEW PARTIAL HEIGHT PARTITION,


7'-6'' HIGH

INSTALL NEW FULL HEIGHT PARTITION (1/2'' GYPSUM BOARD


ON EACH SIDE OF 3 5/8'' METAL STUDS AT 16'' O.C.). USE
WATER - RESISTANT GYP. BOARD ON BATHROOM SIDE.

EXISTING SMOKE DETECTOR


TRAVEL DISTANCE

LEGEND:

NEW KNEE WALL, 3'-0'' HIGH

INSTALL NEW 36'' MIN. GRAB BAR AT REAR WALL.

10

REPAIR/REPLACE EXISTING CEILING IN BATHROOM.

11

INSTALL NEW ADA COMPLIANT SINGLE BATHROOM


DOOR (3'-0'' X 6'-8'') AND FRAME.

12

INSTALL NEW TANKLESS WATER HEATER


UNDER THE SINK.

NEW HEADER AT 7'-0'' MINIMUM HEIGHT.

RELOCATED ELECTRICAL PANEL AND ALARM BOX ABOVE


(SEE ELECTRICAL PLAN)

RELOCATED WALL HUNG SINK AND FAUCET.