Você está na página 1de 2

Attached sheet 2-1

Purchase scope list (General 1/2)

B: Buyer
ST: Supplier of terminal equipment
SF: Supplier of furnace equipment
Basic data

Design

Supply

Transportation

Erection

ST
ST
ST
SF
SF
SF
SF
ST
ST
ST
ST
ST
ST
SF

ST
ST
ST
SF
SF
SF
SF
ST
ST
ST
ST
ST
ST
SF

ST
ST
ST
SF
SF
SF
SF
ST
ST
ST
ST
ST
ST
SF

ST
ST
ST
SF
SF
SF
SF
ST
ST
ST
ST
ST
ST
SF

SF
ST
SF
ST
SF
B
B
ST,SF,B
ST,SF
ST,SF
SF

SF
ST
SF
ST
SF
SF
ST
SF
SF
SF
SF

SF
ST
SF
ST
SF
SF
ST
SF
SF
SF
SF

Instrumentation equipment
Instrumentation for terminal
Instrumentation for furnace

ST
SF

ST
SF

Level 2 Computer

SF

Level 3 Computer

Commissioning Commissioning

Operation and
Remarks
Maintenance SV

(No load test)

(Cold run & Hot run)

ST
ST
ST
SF
SF
SF
SF
ST
ST
ST
ST
ST
ST
SF

ST
ST
ST
SF
SF
SF
SF
ST
ST
ST
ST
ST
ST
SF

ST *1
ST *1
ST *1
SF *1
SF *1
SF *1
SF *1
ST *1
ST *1
ST *1
ST *1
ST *1
ST *1
SF *1

*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1

Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total

coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination

is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer

SF
ST
SF
ST
SF
SF
ST
SF
SF
SF
SF

SF
ST
SF
ST
SF
SF
ST
SF
SF
SF
SF

SF *1
ST
SF
ST
SF
SF
ST
SF
SF
ST,SF
SF

SF *1
ST *1
SF *1
ST *1
SF *1
SF *1
ST *1
SF *1
SF *1
SF *1
SF *1

*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1

Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total

coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination
coordination

is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer
is buyer

ST
SF

ST
SF

ST
SF

ST
SF

ST *1
SF *1

*1 Total coordination is buyer


*1 Total coordination is buyer

SF

SF

SF

SF

SF

SF *1

*1 Total coordination is buyer

Special tools for terminal


Special tools for furnace
General tools

ST
SF
B

ST
SF
B

ST
SF
B

ST
SF
B

ST
SF
B

ST
SF
B

ST
SF
B

Piping for turminal


Piping for furnace

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST,SF

EI construction material for terminal


EIC construction material for furnace

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

Lighting for terminal


Lighting for furnace

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

GAPL
Mechanical and Furnace equipment
Entry section
Cleaning section
Entry looper section
No.1 Furnace section
Galvanizing section
No.2 Furnace section
No.1 Post treatment section
Skinpass mill section
No.2 Post treatment section
Delivery looper section
Trimmer section
Delivery section
Auxiliary system for terminal
Auxiliary system for furnace
Electrical equipment
Master controller (General)
Master controller for terminal
Master controller for furnace
Electrical equipment for terminal
Electrical equipment for furnace
Electrical equipment for Aux. power
Electrical equipment for Aux. power
DG for GAPL (emergency)
Power incoming panel
ITV for GAPL
Intercom for GAPL

Main piping in the building

(terminal)
(terminal)
(terminal)
(furnace)
(furnace)
(furnace)
(furnace)
(terminal)
(terminal)
(terminal)
(terminal)
(terminal)

Attached sheet 2-1

Purchase scope list (General 2/2)

B: Buyer
ST: Supplier of terminal equipment
SF: Supplier of furnace equipment
Basic data

Design

Supply

Transportation

Erection

Grouding for terminal


Grouding for furnace

ST
SF

ST
SF

ST
SF

ST
SF

Pot compornents maintenance equipment

SF

SF

SF

Scrap bucket

ST

ST

Bottom dross remover

SF

Dust cover for center and delivery section

Commissioning Commissioning

Operation and
Remarks
Maintenance SV

(No load test)

(Cold run & Hot run)

ST
SF

ST
SF

ST
SF

SF

SF

SF

SF

ST

ST

ST

ST

ST

SF

SF

SF

SF

SF

SF

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

Foundation bolts

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

Drainage pumps

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

ST, SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

ST
SF

Auxiliary
Over head crane
equipment
Hoist

ST, SF

ST, SF

Building

Main building
Entry pulpit
Center pulpit
Delivery pulpit
Entry electrical room
Center electrical room
Delivery electrical room
Skinpass mill and No.2 post treatment sub building

ST, SF
ST, (SF)
SF, (ST)
ST, (SF)
ST, (SF)
SF, (ST)
ST, (SF)
ST

B
B
B
B
B
B
B
B

B
B
B
B
B
B
B
B

B
B
B
B
B
B
B
B

B
B
B
B
B
B
B
B

B
B
B
B
B
B
B
B

B
B
B
B
B
B
B
B

Civil

Civil work for GAPL equipment


Civil work for building
Embedded type anchor frame

ST, SF
B
ST, SF

B
B
ST, SF

B
B
ST, SF

B
B
ST, SF

B
B
B

B
B
-

B
B
-

Utility

Power supply system


Water supply system
Cooling water system
Natural gas supply system
N2 gas supply system
H2 gas supply system
Compressed air supply system

ST, SF
ST, SF
ST, SF
SF
SF
SF
ST, SF

B
B
B
B
B
B
B

B
B
B
B
B
B
B

B
B
B
B
B
B
B

B
B
B
B
B
B
B

B
B
B
B
B
B
B

B
B
B
B
B
B
B

Water
treatment

Waste water treatment system

ST, SF

Others

Initial charge oil and grease


Chemicals
Ingot for coating pot

ST, SF
B
B

B
B
B

B
B
B

ST, SF
B
B

GAPL

Commissioning tools for terminal


Commissioning tools for furnace

excluding spare and/or exchange