Escolar Documentos
Profissional Documentos
Cultura Documentos
HIGHLIGHTS :
MAKE : SIEMENS
MODEL :HIPATH - 4000
CAPACITY : 3000 Lines expandable up to 5760 lines
CONFIGURATION :
ANALOG SUBSCRIBER LINES : 3000 ( 1200 ohms)
DIGITAL LINES
: 48
ANALOG LONG LINES
: 104 ( 3000 ohms)
LD TIE LINE TRUNKS
: 110
E1 IN COMING TRUNKS
: 30 Channel
HOT LINES
: 50
PRI- TRUNKS
:4 x 30 =120
FEATURES :
IP- COMPATIBLE
ISDN EXCHANGE
OFC ADAPTABILITY
E1- ADAPTABILITY
REMOTE MAINTENACE INTERFACE
LAN CONNECTIVITY
IVR SYSTEM
CALL BILLING SYSTEM
REDUNDANCY
SINGLE CONTROL UNIT
UNIVERSAL SLOTS
PENTIUM PROCESSOR
FACILITIES :
AUTO CALL BACK ON BUSY / NO ANSWER
WAKE-UP / REMINDER ALARM
CALL PICK-UP
DO NOT DISTURB
CALL FORWARD
CALL TRANSFER
3- PARTY CONFERENCE
TOWNSHIP
EXCHANGE
PLANT
EXCHANGE
120- PRI + 60 LD Tie
30-E1-Channel ( I/C)
BSNL
EXCHANGE
SECOTR-VIII
Township Telephone Exchange is physically located
in sector-7 area of township and is connected to Plant
Exchange(PLX) through 120 numbers of PRI and 60 numbers of LD
tie / trunk lines. These two exchanges are connected through 4-PRI
channels 60- both way auto-auto type LD trunk lines. The
numbering scheme used in these two exchanges is a closed
numbering scheme and consists of 5 digits . There is no need to dial
any prefix or suffix for dialing any number in township and plant
areas. The telephone numbers in township exchange are in 8600088999 range and in Plant exchange it is 21000Township Exchange is also connected to BSNL
network by a 30 channel Incoming E1 stream. Through this is E-1
stream subscribers of BSNL network can land onto Township
Exchange telephone numbers by adding a prefix of 288 before their
five digit 8-series numbers of the township exchange.
440 V OLTS 3
PHASE
INCOMING
POWER SUPPLY
CUBICLE
SWITCH MODE
RECTIFIERUNIT-1
DC SWITCHING
SWITCH MODE
RECTIFIERUNIT-2
CUBICLE
VRLA -BATTERY
BANK -I
VRLA -BATTERY
BANK -2
48 V DC VOLTAGE
SWITCH
ADMIN &
MAINTENANCECONSOLE
existing power plant and battery banks. In the supplied Manual Switching
Cubicle unit , provision is there to connect / disconnect SMP1,
SMP2,Battery bank-1 & Battery bank-2 using simple knife edge switches in
any combination. The Load terminal of the supplied Manual Switching Cubicle
unit is permanently connected to the exchange load . Also the
supplied Manual Switching Cubicle unit is housed in a separate
compartment and segregated from others.
In the event of mains power failure the Exchange will be be
automatically connected to battery supply without any interruption.
1 no of Manual Switching cubicle
units and batteries as and when required . All the connections from the
SMP1&2 ,Battery 1&2 and the load (Exchange) are terminated in this
unit. Selection of SMPs and Battery can be done by using two switches
provided on the front panel.
2 nos of VRLA Battery banks
Standby .The PSU s in the sub racks derives the different voltages of
+5V DC , -5V DC,+12 V DC and 12 V DC from the available 48V DC.
CALL PROCESSING :
The total call processing or communication between any two
subscribers is basically divided into two parts :
a) Signaling
b) Speech transfer
The processor continuously monitors all the lines for any loop in a
pre-determined time intervals ( milli seconds). The various sequence
operations that takes place during signaling are :
When any of the subscriber lifts his telephone hand set, the loop
will be detected by the exchange and the dial tone will be
switched .
The analog electrical voice signals from the telephone hand set
transmitter of the originator number / destination number
reaches the SLMA card in the switch.
The analog speech signals are then converted into digital form
by using A/D converters.
CCB
MTSCG
SICOE
ADP
CC A / B
DPC-5
QDCL
SICOE
MTSCG
LTU
QDCL
DPC-5
MTSCG
SICOE
QDCL
DPC-5
ADP
CCA
LTU-1
LTU-2
LTU-12
LTU-15
Acronyms :
FUNCTION
24 port analog subscriber line card
8 port long line card
2 port LD trunk card
8 port CO trunk card
Ringer card
Tones card
LTU interface card
Processor card
Tones & DTMF card
Clock generator
LAN connectivity card
Hard disk drive / Magneto optical disk
4. MAC-Consoles
: for MAN MACHINE INTERFACE :
Time of origination
All the dial tones from the exchange are available in the Krone MDF
which are provided with IPM s so as to protect the exchange
equipment from the external high currents and voltage. The dial tones
are extended to the field side MDF via IPMs and jumper wires .Similarly
all the trunk circuits are available in the Krone MDF and these trunks
are further connected to PLEX trunks / BSNL trunks in the MDF.
Main Distribution Frame (MDF) is of four thousand (4000)
port capacity and equipped with 40 nos.of 100 pair CT blocks with 11
way back mount frame and 2/10 disconnection modules mounted on a
painted ,prefabricated steel structured frame and seamless interface
for termination exchange cables & field cables, provided with hooks &
rings for jumpers ,with
Integrated Protection Modules (IPM)s which
consists of PTCs and Gas Discharge Tubes for all the ports (Lines,
Trunks)of KRONE-make.
The MDF is provided with cable connections in the rear,
channels for running the cables, twin insulation Displacement type
contacts, test plugs, front access to jumper connection tags/ferrules,
replaceable contacts ,rubber floor mat covering entire MDF area etc.
Check
Check the DT at the
DIAGNOSIS
Fault may be in the
complaint
IPM/jumper/field MDF
If the DT is there in
the previous number
and next
number,SLMA24 card
may be faulty. Replace
the card .
Fault in junction lines.
getting / plant
continuously ..
working
card
MDF
( 30 numbers ) If YES
If NO
To be informed to the
BSNL exchange
LIST OF ABBREVATIONS :
SLMA
SLMAR
SLMO
Analog
Subscriber Line Module Rural 8 port Long Line card
Subscriber Line Module , U
24 port -Digital Card
DIUC
LTUCX
p/o interface
Digital Interface Unit Card
Line Trunk Unit Control
E1-connectivity card
LTU interface card
RGE
MTSCG
Extended
Ring Generator
Memory Time Switch and
Ringer card
Control Card for Clock generation and
SICOE
Clock Generator
Signaling Unit and
memory
Tones, MOH, DTMF etc.,
HUB
CC
ADP
LAN card
Control Processor Sub rack
Administration Control
QDCL
Processor
Quad Data Communication..
Link
Data Processor & Common
Power Supply Unit
DPC-5
PSU
BLOCK DIAGRAM :
Line1
HDSL Pair-1
Line-1
RT-1
Line-15
Line 15
COT
Line 1
HDSL Pair-2
RT-2
Line-1
Line-15
Line 15
Dail tones from the
Cable pairs of
WORKING
exchangePRINCIPLE
are fed to:
existing cable
COT on the source/
sender side
The system consists of 2 major components :
The RT which is located at a remote location gets the HDSL pair as its
input and decodes the channel and derives the original dial tones that
are fed on the COT side as it is. The dial tones those are out putted
from the RT can be further distributed as per the requirement in the
site.
ADVANTAGES :