INSTALLATION AND MAINTENANCE INSTRUCTIONS

12 Clintonville Rd
Northford, CT 06472-1653
(203) 484-7161

FZM-1 Interface Module

Ripple Voltage:
Current:
Temperature Range:
Humidity:
Dimensions:
Accessories:

15 to 32 VDC
5.1 mA (LED on)
270A (LED flashing)
3.9K Ohms
25 Ohms
Terminals T3 and T4)
18-28 volts power limited (19 to 28VDC when used with MTL isolator model MTL3043 in
intrinsically safe applications)
0.1 Volts RMS maximum
90mA per module
32F to 120F (0C to 49C)
10% to 93% Noncondensing
41/2 H x 4 W x 11/4 D (Mounts to a 4 square by 21/8 deep box.)
SMB500 Electrical Box

Before Installing
This information is included as a quick reference installation guide. Refer to the control panel installation manual
for detailed system information. If the modules will be
installed in an existing operational system, inform the
operator and local authority that the system will be temporarily out of service. Disconnect power to the control panel
before installing the modules.

1. Install module wiring in accordance with the job drawings and appropriate wiring diagrams.
2. Set the address on the module per job drawings.
Note: Some panels support extended addressing. In
order to set the module above address 99 on compatible
systems, carefully remove the stop on the upper rotary
switch with thumb in the direction shown in Figure 1.
3. Secure module to electrical box (supplied by installer),
as shown in Figure 2A.

NOTICE: This manual should be left with the owner/user


of this equipment.

Figure 1. Removing
Rotary Switch Stop:

General Description
The FZM-1 Interface Module is intended for use in intelligent, two-wire systems, where the individual address of
each module is selected using the built-in rotary switches.
This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It transmits the
status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire
detectors being monitored must be UL compatible with this
module. The FZM-1 has a panel controlled LED indicator
and can be used to replace an MMX-2 module in existing
systems.

8
7
6
5
LOOP

ONES

1
2
3
4

ADDRESS

A78-2318-07

Figure 2B:
0

Wiring
NOTE: All wiring must conform to applicable local codes,
ordinances, and regulations. This module is intended for power-limited wiring only.

4 5 67
8
3
9
2
10
TE
NS 1
11
0
4 5 6 7 15 1 1 12
8 4 3
2
9
1
0

Mounting
The FZM-1 mounts directly to 4 square electrical boxes (see
Figure 2A). The box must have a minimum depth of 21/8 .
Surface mounted electrical boxes (SMB500) are available
from Notifier

www.PDF-Zoo.com

67 8 9
5
10
11
4
3
12
13
2
1 0 15 14
TENS
8
7
6
9
5
4
3
2
10

Figure 2A. Module mounting:

Compatibility Requirements
To ensure proper operation, this module shall be connected
to a compatible Notifier system control panel only (list
available from Notifier).

N500-49-00

S
ONE

4 5 67
8
3
9
2
10
TE
NS 1
11
0
5
1
4 6 7 5 1 1 12
3
8 4 3
2
9
1
0

Specifications
Normal Operating Voltage:
Maximum Current Draw:
Average Operating Current:
EOL Resistance:
Maximum IDC wiring resistance:
External Supply Voltage (between
DC Voltage:

ES
ON

4
ES

DR

AD

ES
DR
AD

A78-2611-12

A78-2610-10

I56-1172-06

Figure 3. Interface two-wire conventional


detectors, NFPA Style B:

COMMUNICATION LINE
32 VDC MAX.
TWISTED PAIR
IS RECOMMENDED

)(

TO NEXT

)+(

DEVICE

CONNECT MODULES TO LISTED


COMPATIBLE CONTROL PANELS ONLY.

)(
)+(

FROM PANEL OR
PREVIOUS DEVICE

INTERFACE
MODULE

TERMINAL WIRING MUST BE POWER LIMITED.

DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY,


OR SECURITY DEVICES ON THE SAME MODULE.

9
8
7
6
5

3.9K EOL
RESISTOR
(INCLUDED)
A2143-10

LOOP

67 8 9
5
10
11
4
3
12
13
2
1 0 15 14
TENS
6789
5
4
3
2
10

ONES

)(

)+(

)(

LISTED BATTERY-BACKUP SWITCHED


DC POWER SUPPLY.

)+(

ADDRESS

POWER TO THE INTERFACE MODULE


MUST BE EXTERNALLY SWITCHED TO
RESET THE DETECTORS. AN FRM-1
RELAY CONTROL MODULE CAN BE USED TO
SWITCH POWER FROM A STANDARD
POWER SUPPLY - SEE FIGURE 5.

DO NOT LOOP WIRE UNDER TERMINALS. BREAK WIRE


RUN TO PROVIDE SUPERVISION OF CONNECTIONS.
DETECTORS MUST BE UL LISTED COMPATIBLE WITH MODULE.
INSTALL DETECTORS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS.

OPTIONAL BRANCH CIRCUIT


TO NEXT INTERFACE MODULE.
MODULE SUPERVISES SUPPLY
VOLTAGE AND DETECTOR LOOP.

Figure 5. Relay control module


used to disconnect a power supply:

Figure 4. Interface two-wire conventional


detectors, NFPA Style D:
COMMUNICATION LINE CONNECT MODULES
TO LISTED COMPATIBLE
32 VDC MAX.
CONTROL PANELS ONLY.
TWISTED PAIR
IS RECOMMENDED

TERMINAL WIRING MUST BE POWER LIMITED.


DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY,
OR SECURITY DEVICES ON THE SAME MODULE.

A78-2394-14

TO NEXT
DEVICE

)(

)(

)+(

)+(

COMMUNICATION LINE
CONNECT MODULES
32 VDC MAX.
TO LISTED COMPATIBLE
TWISTED PAIR
IS RECOMMENDED CONTROL PANELS ONLY.

FROM PANEL
OR PREVIOUS
DEVICE

TO NEXT
DEVICE

)(

)(

)+(

)+(

RELAY
CONTROL
MODULE

INTERFACE
MODULE

9
8

3.9K EOL RESISTOR


REQUIRED AT TERMINALS
8 & 9 (INCLUDED)
A2143-10

7
6
5
LOOP

67 8 9
5
10
11
4
3
12
13
2
1 0 15 14
TENS
6789
5
4
3
2
10

ONES

POWER LIMITED
DC POWER SUPPLY,
LISTED FOR FIRE )+(
PROTECTION
WITH BATTERY )(
BACKUP

)(

)+(

)(
)+(

3
4

ADDRESS

)(

LISTED BATTERY-BACKUP,
SWITCHED DC POWER SUPPLY.

6
5

)+(
LOOP

)(
)+(

3
4
ADDRESS

POWER TO THE INTERFACE MODULE


MUST BE EXTERNALLY SWITCHED TO
RESET THE DETECTORS. AN FRM-1
RELAY CONTROL MODULE CAN BE USED
TO SWITCH POWER FROM A STANDARD
POWER SUPPLY - SEE FIGURE 5.

DO NOT LOOP WIRE UNDER TERMINALS. BREAK WIRE


RUN TO PROVIDE SUPERVISION OF CONNECTIONS.
DETECTORS MUST BE UL LISTED COMPATIBLE WITH MODULE.
INSTALL DETECTORS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS.

OPTIONAL BRANCH CIRCUIT


TO NEXT INTERFACE MODULE.
MODULE SUPERVISES SUPPLY
VOLTAGE AND DETECTOR LOOP.

FROM
PANEL OR
PREVIOUS
DEVICE

A78-2396-10

A78-2395-14

Figure 6. Interface two-wire intrinsically


safe conventional detectors, NFPA Style B:

)(

TO NEXT

COMMUNICATION LINE
32 VDC MAX.
TWISTED PAIR
IS RECOMMENDED

)+(

DEVICE

CONNECT MODULES TO LISTED


COMPATIBLE CONTROL PANELS ONLY.

)(
)+(

FROM PANEL OR

PREVIOUS DEVICE

INTERFACE
MODULE

TERMINAL WIRING MUST BE POWER LIMITED.


DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY,
OR SECURITY DEVICES ON THE SAME MODULE.

9
8
7
6
5

3.9K EOL
RESISTOR
(INCLUDED)
A2143-10

LOOP

67 8 9
5
10
11
4
3
12
13
2
1 0 15 14
TENS
6789
5
4
3
2
10

ONES

0
1
2

)(
)+(

RESET THE DETECTORS. AN FRM-1


RELAY CONTROL MODULE CAN BE USED TO
SWITCH POWER FROM A STANDARD

MTL3043 ISOLATOR

N500-49-00

LISTED BATTERY-BACKUP SWITCHED


DC POWER SUPPLY.

ADDRESS

POWER TO THE INTERFACE MODULE


MUST BE EXTERNALLY SWITCHED TO

POWER SUPPLY - SEE FIGURE 5.

DO NOT LOOP WIRE UNDER TERMINALS. BREAK WIRE


RUN TO PROVIDE SUPERVISION OF CONNECTIONS.
DETECTORS MUST BE UL LISTED COMPATIBLE WITH MODULE.
INSTALL DETECTORS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS.

www.PDF-Zoo.com

)(
)+(

OPTIONAL BRANCH CIRCUIT


TO NEXT INTERFACE MODULE.
MODULE SUPERVISES SUPPLY
VOLTAGE AND DETECTOR LOOP.

A78-2394-29

I56-1172-06
2001 Notifier