Evaluation of a Chiller Plant


Sizing and selecting a replacement chiller based on sustainability considerations
for a high-base-load cooling application
By ARVIND AKELA, PE, CEM, LEED AP BD+C; CDM Smith Inc.; Walnut Creek, Calif. |
HPAC Engineering
SHARE

Sep 10, 2013

COMMENTS 0

TWEET

The recommendations offer a solution that meets the


clients corporate sustainability goals and reduces
energy costs significantly.

What is in this article?:


Evaluation of a Chiller Plant
Methodology
Chilled-Water Distribution System
Control Strategy for Variable Flow

Blogs & Opinions


Blogs

Conclusions

A client with a commitment to sustainability operates a three-story, 108,000-sq-ft


commercial building in San Jose, Calif. The majority of the buildings cooling load comes
from computers and high-power workstations that run continuously. The building is
served by a chiller plant consisting of three chillers:
The new 160-ton-nominal-capacity Chiller 1, which was installed to replace a 150-ton
chiller.
The 150-ton-nominal-capacity Chiller 2, which dates from the buildings late 1980s
construction.
The 190-ton-nominal-capacity Chiller 3, which was installed approximately 10 years ago
to increase chiller-plant capacity. It shows wear and tear, but is reported to be in good
working condition.
Three 15-hp chilled-water pumps, each rated for 350 gpm, serve a closed-loop
chilled-water distribution system. In normal operation, two pumps and two chillers
(chillers 1 and 2) run to circulate an average of 700 gal. of chilled water per minute to
meet the buildings cooling load. In the pump room, a pressure-controlled bypass valve
between the supply and return pipes maintains constant flow through the pumps and
chillers. An override selector switch in the pump room provides three operating
combinations: chillers 1 and 2, chillers 2 and 3, and chillers 1 and 3.

Columns

Saluting Green-Building, HVACR


Industries Efforts to Employ Veterans
by Lawrence (Larry) Clark, QCxP,
GGP, LEED AP+
Posted 6 days ago
in Clark's Remarks

Where Is the Value in HVAC Value


Engineering?
by Lawrence (Larry) Clark, QCxP,
GGP, LEED AP+
Posted 2 weeks ago
in Clark's Remarks

Refrigerant Additives Revisited


by Lawrence (Larry) Clark, QCxP,
GGP, LEED AP+
Posted 4 weeks ago
in Clark's Remarks

Because of its age and wear, Chiller 2 was targeted for replacement by the owner.
A recommendation that Chiller 2 be replaced with sustainable equipment that surpasses
code-mandated levels of efficiency and provides control strategies to improve chilledwater-plant energy efficiency was made. This article describes the analysis behind that
recommendation.
Methodology

Tweets by @HPACEng
1 2 3 4 5 Next
SHARE

Discuss this Article

POSTING AS:

Advertisement

TWEET

kamal_haziq

(Sign Out)
YOUR COMMENT: *

SUBMIT COMMENT

Newsletter Signup
Sign-up to receive our free newsletters
HPAC Engineering Fastrack - (Bi-Weekly) View Sample
E-MAIL*
COUNTRY*
Enter your email above to receive messages about offerings by Penton, its brands, affiliates and/or third-party partners,
consistent with Pentons Privacy Policy.

Related Articles
Rethinking Central Utility Plants
Canada's First Ultraefficient Chiller Plant

27/4/2015 11:24 AM

Você também pode gostar