Operators Manual
D I G I T A L C O N T R O L L ER 5 0 0 2 U
Operators Manual
Page 1 of 20
masibus
CONTENTS
1. TECHNICAL DETAILS
2. SPECIFICATIONS
3. DIMENSIONS & PANEL CUTOUT
4. FRONT FASCIA
5. CONNECTIONS DETAIL
6. USER GUIDE
7. MODE OF OPERATION
8. MODBUS DETAIL (OPTIONAL)
9. COMMUNICATION PARAMETERS
10. TROUBLE SHOOTING
Operators Manual
Page 2 of 20
masibus
1.
TECHNICAL DETAILS
instrument is
user-friendly
Page 3 of 20
masibus
2.
SPECIFICATIONS
DISPLAY
INPUT
Calibration
-200 to 1000 C
-200 to 1200 C
-200 to 1372 C
-200 to 400 C
450 to 1820 C
0 to 1768
C
0 to 1768
C
-200 to 1300 C
0 to 2320
C
0 to 2320
C
-199.9 to 850.0 C
-1999 to 9999
-1999 to 9999
-1999 to 9999
-1999 to 9999
-1999 to 9999
0 to 2000
Operators Manual
GENERAL
RANGE
E
J
K
T
B
R
S
N
G
C
PT100
4-20 mA dc
0-20 mA dc
1-5 V dc
0-5 V dc
0-100 mV dc
+
0-2V dc
Power supply:
110V/230V ac 50Hz
(Internal Jumper selectable),
24V DC (optional) or
24V AC (optional)
Ambient Temperature:
0 to 55 C
Humidity:
20% to 95% RH non-condensing
Power consumption:
Less than 10 VA
PHYSICAL
Case:
M.S. powder coated with ABS
molded bezel
Terminals:
PCB type terminal block can accept
up to 2.5 mm wire
Bezel size:
96 X 96 mm
Depth behind Panel:
200 mm maximum including
Page 4 of 20
masibus
3.
terminals
Panel cutout:
92 X 92 mm
DIMENSIONS &
PANEL CUTOUT
No of Supply
:1
Voltage Rating : 24 V dc @ 20 mA
Isolated output
Isolation
: 500 V dc
Isolated
Serial
(Optional *)
Communication
Communication standard:
RS-485
Communication Protocol:
Modbus RTU
Distance of Communication:
1200 meter (Twisted pair cable as
per EIA 485 standard)
Maximum Slaves:
32 without repeaters
Isolation:
500 V dc
No of Output:
1.
Isolation:
500 VDC
*
Note: 5002u digital controller
will come with Isolated serial or
Isolated retransmission O/P.
**
Note: 5002u digital controller
with 0-2V input type only has
facility of configurable RX output.
User can set zero and span for RX
output in configuration mode.
Operators Manual
Page 5 of 20
masibus
4.
FRONT FASCIA
PV : Process Value
SV : Default Set-Point Value
RL1,RL2,RL3:Relay Status On/Off
Some application RL1 is not used,
RL2 is used for Alert Operation &
RL3 is used for danger Operation
RX,TX: Serial Data Transmit and
Receive Status
SP1, SP2,SP3:Default Set-points
Displayed on SV Window
SET: Indexing Parameter in Various
Modes
ENTER: Saves Desired Parameter in
Various Mode
INCR: Increments the Selected
Parameter Value to Desired Value
DECR: Decrements the Selected
Parameter Value to Desired Value
Note:
Operators Manual
5.
CONNECTIONS
DETAIL
Page 6 of 20
masibus
6.
6.1
USER GUIDE
INTRODUCTION
DTC 5002U is an on-off controller userfriendly key-pad and display for guiding
the
user
with
programming
and
calibration operation. The manual covers
all
aspects
of
operation
of
the
instrument. Users are requested to go
read the instructions carefully before
altering any configuration.
6.2
POWER SUPPLY
Before
connecting
power
to
the
instrument
ensure
that
you
are
connecting right input voltage to right
terminal. The instrument is having
terminals for both 110V ac and 230V ac
or 24V dc. On application of correct
power supply, the instrument will display
input type set, for five seconds.
Once the input is applied, its value will
be displayed in PV window and presently
selected set-points will be displayed in
the SV display along with appropriate
set-point LED.
6.3
KEY BOARD
Sp1
Hys1
Sp2
Hys2
Sp3
Hys3
ENTER
This key is used for entering into mode
(CALb Or ConF) and for entering the
value of the selected parameter. After
setting the data to proper value, if enter
key is pressed, the data will be
permanently stored in non-volatile
memory. On pressing of enter key,
display shows the parameter which you
have entered. Now data change is not
possible until Enter key pressed once
again. On pressing of Enter key decimal
point on last digit will glow and allow
changing data.
INC ()
DEC ()
This key is used to select the desired
operating mode and parameter in
various operating modes. On first press
of this key in RUN mode for 3 second, it
will display PASS in PV (Process value)
window.
PASS
Setpoint1
Operators Manual
Page 7 of 20
masibus
mode
By pressing INC/DEC Key, user can view
operating modes (CALb Or ConF) in
PV (Process value) window and by
pressing Enter key unit will enter into
that particular operating mode.
Conf
Calb
After Entering into operating mode
(CALb Or ConF), first parameter will be
displayed in SV window and by Pressing
select key subsequent parameter will be
displayed.
Corresponding
parameter
values will be displayed in PV window.
By pressing INC/DEC Key, user can
select desired value and by pressing
ENTER Key, user can store selected
value. After the last parameter is
displayed, pressing of SEL key for 3
second will bring the instrument in Run
mode.
This key will also decrement the selected
parameter value by one count in all
operation modes.
If the key is pressed continuously than
the rate of decrement will be made five
times faster. This facility is called dual
speed decrement facility to allow faster
data change for higher values. This key
is also used to move onto different mode
(calibration and configuration).
7.
There
MODE OF
OPERATION
SET-POINTS &
HYSTERESIS EFFECTS
For set-points selection, there are three
different options, which can be selected
for a particular set-point.
On-Above/On-Below Set-point
If user selects on above set-point option,
the relay will be energized when the
process variable is more than set
variable. In case of on below set-point
operation of relay is reverse.
Control/ Alarm Set-point
In the case of control set-point the
Hysteresis effect is different from alarm
type. In case of alarm set-point, the
relay can be acknowledged on pressing
of ENTER key in run mode. So, this
selection should be done carefully
according to application.
Absolute/ Deviation Set-point
Deviation option is applicable only for
second and third set-points. In case of
deviation set-point, it is added to the
first set-point to derive the actual setpoint.
This set-point selection can be done by
changing the configuration. Refer to
section on reconfiguration elsewhere in
this manual.
Now, let us see an example to illustrate
the effect of Hysteresis setting on relay
operation.
For control set-point and
alarm set-point the effect of Hysteresis
is little different so we will consider each
case separately.
Suppose you have selected a set-point
of 200 and Hysteresis of 5. Also the
setting is for control type and on below
set-point. So in this case the Hysteresis
effect is applicable while turning ON the
relay. The relay will turn off exactly at
200 after being turned on. But it will not
turn on once again until temperature
falls below 200 - 5 = 195. This provides
a band of 5 around the set-point. In
Page 8 of 20
masibus
RUN MODE
PASSWORD MODE
PROGRAM MODE
This mode is used for programming setpoints. In this mode set-points data can
be checked and reprogrammed.
For entering this mode press select key,
It will display first set-point parameter.
By pressing INC/DEC keys value of the
set-points and Hysteresis can be
changed as desired.
Operators Manual
Sp1
Hys1
Sp2
Hys2
Sp3
Hys3
Setpoint1
Hysteresis for first set-point
Setpoint2
Hysteresis for second set-point
Setpoint3
Hysteresis for Third set-point
CONFIGURATION MODE
Page 9 of 20
masibus
Inpt
zerO
SpaN
NOSP
Tsp1
Tsp2
Tsp3
D SP
dp
OPSE
PASS
init
SLOt
Byps
Zero setting
Span setting
Number of set-point
Type of first set-point
Type of second set-point
Type of third set-point
Default Display set-point
Decimal point position
Open sensor
Password
Initialization
Slot configuration
Bypass selection[used to
bypass 3rd Relay and
RL3 LED Indication in
front]
Serial No
7.6
srNo
baud
rt-Z
Baud Rate
RX zero setting [ Applicable
rt-S
Input Type
Inpt
E-tc
J-tc
K-tc
T-tc
B-tc
R-tc
S-tc
0 to 1768
input
0 to 1768
Operators Manual
zerO
spaN
Zero and span setting are used for
selecting range for all inputs.
This
allows selecting any value between
-1999 to 9999 for the range of the all.
Page 10 of 20
masibus
Operators Manual
Page 11 of 20
masibus
Retransmission o/p
NO output
rtrC
Serial communication
COMC
none
Serial Number
This parameter is basically used for
Modbus communication, to identify the
unit. Modbus communication is master
and slave communication, in which
master will send query and slave will
give response. If there are multiple
slaves connected, so to synchronies
communication,
slave
has
its
identification no (serial no) and it
responds to only those query, which
have its serial no. Range of serial no is
from 1 to 99.
Srno
0 to 99
This parameter is required while using
the Serial Communication facility. It
represents the serial number or the ID
number of the Unit. It can be configured
between 1 and 99 by using INC/DEC
keys.
Baud Rate
bd
9600 19.2k
Page 12 of 20
masibus
Cals
Cala
rtrz
Rt-z
Rt-s
This allows selecting any value between
0 to 2000. This range can be changed
any time, to make instrument usable for
any type of 4-20 mA output transmitters
or such other instrument.
CALIBRATION MODE
The
instrument
is
factory
calibrated for the specified range, but
due to long term drift of components,
recalibration may be necessary in some
cases. For calibrating the instrument a
reliable source is required. This source
should be at least ten times accurate
compared
to
the
range
of
the
instrument.
The unit can be calibrated
without opening it and without trimpots.
For entering this mode press select key,
PASS will be displayed, now enter
correct password and press enter key to
enter in menu mode and then
INCR/DECR to choose Calibration mode
and then press Enter key. It will display
first calibration parameter. Now the
subsequent calibration parameter can be
viewed by pressing the select key. The
parameters in sequence are as below.
Calz
- Zero Calibration
Operators Manual
-Span Calibration
-Ambient Calibration.
- Retransmission zero
Calibration [ Applicable for
Retransmission Option ]
-Retransmission span
rtrs
Calibration [ Applicable .
for Retransmission Option]
Page 13 of 20
masibus
ISOLATED
SIGNAL
RETRANSMISSION
7.7
masibus
8.
8.1
MODBUS DETAIL
INTRODUCTION
COMMUNICATION PROTOCOL
Operators Manual
Page 15 of 20
masibus
CRC to the message. The receiving
device recalculates a CRC during receipt
of the message, and compares the
calculated value to the actual value it
received in the CRC field. If the two
values are not equal, an error is
encountered.
The CRC is started by first pre loading a
16-bit register to all 1's. Then a process
begins of applying successive eight-bit
bytes of the message to the current
contents of the register. Only the eight
bits of data in each character are used
for generating the CRC. Start and stop
bits, and the parity bit, do not apply to
the CRC.
During generation of the CRC, each
eight-bit character is exclusive ORed
with the register contents. Then the
result is shifted in the direction of the
least significant bit (LSB), with a zero
filled into the most significant bit (MSB)
position. The LSB is extracted and
examined. If the LSB was a 1, the
register is then exclusive ORed with a
preset, fixed value. If the LSB was a 0,
no exclusive OR takes place.
This process is repeated until eight shifts
have been performed. After the last
(eighth) shift, the next eight-bit byte is
exclusive ORed with the register's
current value, and the process repeats
for eight more shifts as described above.
The final content of the register, after all
the bytes of the message have been
applied, is the CRC value.
When the CRC is appended to the
message,
the
low-order
byte
is
appended first, followed by the highorder byte.
8.2.9 MESSAGE RESPONSE
Page 16 of 20
masibus
Data Field
9.4
CHECKSUM COMPUTATION
9.
9.1
COMMUNICATION
PROTOCOL
DELAY AND ADDRESS
9.5
FUNCTION
Operators Manual
EXCEPTION RESPONSE
MEANING
Function code Invalid.
It must be 01, 05, 03 or
06.
Illegal data starting address.
The range is specified for
different functions in the
Table below.
Illegal data value. The range
is specified for different
Functions in the table below.
Check sum (CRC) error.
Garbled message.
Page 17 of 20
masibus
RELAY 2
Read
Bit
00002
RELAY 3
Read
Bit
00003
Analog
Paramete
r
Process
Value
Set-point 1
Set-point 2
Set-point 3
Read/
write
Int
40004
Set-point 1
Hysteresis
Set-point 2
Hysteresis
Set-point 3
Hysteresis
Read/
write
Read/
write
Read/
write
Int
40005
Int
40006
Int
40007
Input Type
Int
40008
No. of set
points
Read/
write
Read/
write
Int
40009
10
Act_zero
Read/
write
Int
40010
11
Act_span
Read/
write
Int
40011
12
Type of
Set-point 1
Read/
write
Int
40012
13
Type of
Set-point 2
Read/
write
Int
40013
14
Type of
Set-point 3
Read/
write
Int
40014
15
No. of Slot
configuration
Decimal
Point
Read/
write
Int
40015
Read/
write
Int
40016
Sr
No
1
6
7
16
Operators Manual
Access
Type
Typ
e
Add
Read
Int
40001
Read/
write
Read/
write
Int
40002
Int
40003
17
18
Open
Sensor
RX Zero
19
RX Span
Read/
write
Read/
write
Read/
write
Int
40017
Int
40018
Int
40019
Note:
1. Display on Digital controller 5002u
will show over when process value
is higher then 5 % of individual span,
at that time Digital controller 5002u
will send process value fed to it to
PC.
2. Same way when process value is
lower then 5 % of individual zero
Digital controllers 5002u will show
under on its display but it will send
process value fed to it to PC.
3. If Digital controller 5002u process
value is out of limit for particular I/P
type then Digital controller 5002u
will show Open on display but it will
send 10000 to PC
4. The serial no of Digital controller
5002u Indicators must be within 00
to 99.
5. Before starting the communication,
match the Baud rate and Sr. no. of
Master and Slave devices.
6. Analog Parameter RX Zero and RX
Span are writable only when input
type 0-2V and Retransmission card is
selected.
10.
1
TROUBLE SHOOTING
masibus
Operators Manual
Page 19 of 20
Operators Manual
masibus
Page 20 of 20