SUNLINE HYDRO

Cassette

HKH - HKW

IR Remote control

035T70077-002

LIST OF CONTENTS
Page
1 - Safety ....................................................................................................................2
2 - Indoor units..........................................................................................................2
3 - Technical Specifications.....................................................................................3
4 - Cooling capacities...............................................................................................3
5 - Dimensions ..........................................................................................................4
6 - Installation............................................................................................................5
7 - Condensate Drainage .........................................................................................6
8 - Water Piping Connections..................................................................................6
9 - Front Panel Installation.......................................................................................7
10 - Wiring Diagram ..................................................................................................7
11 - Service and Maintenance..................................................................................8
Parts List : (Contact York)
Decommissioning, Dismantling and Disposal

1 - Safety

2 - Indoor Units

Installation and maintenance of this air conditioning system


should only be carried out by trained and qualified personnel.
Regular maintenance operations such as cleaning the coils and
air filters must be performed to keep the units in proper operating condition.

GENERAL PRECAUTIONS

CAUTION
Before undertaking any work on the unit, make sure that the
power supply has been disconnected.

ELECTRICAL CONNECTIONS
All electrical wiring and connections must comply with local standards.

Check that the power supply available agrees with nameplate


voltage.
Use adequate line protection.
The unit must be grounded.

2.1 - Indoor Units


Each unit is shipped with the following items :
- mounting brackets.
- a wireless remote controller de type P
- a condensate water pump installed inside the unit.
- a Technical Guide.
- a User's Guide.

3 - Technical Specifications

Indoor
unit
W
W
V/Ph/Hz
m3/h
dBA

Models
Cooling
Heating

Capacity
Power supply
Indoor air flow
Noise level
Unit controls

HKH-HKW
25
6 900
9 400

35
9 900
13 500

Indoor

220/240-1-50
1 260
1 800
39/42/44
39/42/44
Infrared remote control with LCD display
290
290
710
710
710
710
30
41
Male
1/2"
3/4"
1/2"
3/4"

The Nominal Cooling Capacity is based on :


- Indoor Air Temp. 27C DB / 19C WB
EWT = 7C LWT = 12C

The Nominal Heating Capacity is based on :


- Indoor Air Temp. 20C DB
EWT = 45C LWT = 40C

Indoor

H (mm)
W (mm)
D (mm)
Indoor
kgs
Type of connection
Diameter
Inlet
Outlet

Dimensions
Net weight
Piping

4 - Cooling capacities
HKH-HKW 25
Water entering temperature
5C
Water
temp.
diff. C

Total Sensible
capacity capacity
W
W

7C
Flow
l/h

Pressure Total
Sensible
drop
capacity capacity
kPa
W
W

10C
Flow
l/h

Pressure
Total Sensible
drop
capacity capacity
kPa
W
W

Flow Pressure
drop
l/h
kPa

Entering

6549

5689

1129

31

5589

5300

960

23

4215

4215

728

13

air temp.

6260

5564

897

20

5269

5137

753

14

3914

3914

558

25C DB

5909

5426

728

13

4905

4905

602

3582

3582

439

17C WB

5495

5275

590

4498

4498

483

3237

3425

351

Entering

7245

5928

1248

39

6254

5620

1079

29

4786

4786

822

17

air temp.

6913

5871

991

24

5903

5426

847

18

4429

4429

634

10
6

26C DB

6549

5727

803

16

5495

5238

677

11

4084

4084

502

18C WB

6141

5564

659

11

5068

5062

546

3732

3732

401

Entering

7954

6260

1367

47

6900*

5846*

1186*

35

5413

5125

935

22

air temp.

7603

6116

1091

30

6542

5689

941

22

5056

4930

728

13

27C DB

7239

5984

891

20

5495

5495

677

11

4654

4654

571

19C WB

6806

5790

734

13

5702

5282

615

4291

4291

464

Entering

8801

6486

1512

57

7603

6116

1311

43

5984

5407

1029

26

air temp.

8393

6392

1204

36

7189

5947

1029

26

5589

5213

803

16

28C DB

7960

6254

979

24

6762

5758

828

17

5162

4993

634

10

20C WB

7496

6768

809

16

6304

5558

677

11

4755

4755

508

Cooling capacities are given at high fan speed.


* Nominal capacity

4 - Cooling capacities (contd)


HKH-HKW 35
Water entering temperature
5C
Water
temp.
diff. C

Total Sensible
capacity capacity
W
W

7C

Flow
l/h

Pressure Total
Sensible
drop
capacity capacity
kPa
W
W

10C
Flow
l/h

Pressure
Total Sensible
drop
capacity capacity
kPa
W
W

Flow Pressure
drop
l/h
kPa

Entering

9396

8163

1620

43

8019

7605

1377

32

6048

6048

1044

18

air temp.

8982

7983

1287

28

7560

7371

1080

19

5616

5616

801

11

25C DB

8478

7785

1044

18

7038

7038

864

12

5139

5139

630

17C WB

7884

7569

846

12

6453

6453

693

4644

4914

504

Entering

10395

8505

1791

53

8973

8064

1548

40

6867

6867

1179

23

air temp.

9918

8424

1422

33

8469

7785

1215

25

6354

6354

909

14

26C DB

9396

8217

1152

22

7884

7515

972

16

5859

5859

720

18C WB

8811

7983

945

15

7272

7263

783

10

5355

5355

576

Entering

11412

8982

1962

64

9900*

8388*

1701*

48

7767

7353

1341

30

air temp.

10908

8775

1566

41

9387

8163

1350

30

7254

7074

1044

18

27C DB

10386

8586

1278

27

7884

7884

972

16

6678

6678

819

11

19C WB

9765

8307

1053

18

8181

7578

882

13

6156

6156

666

Entering

12627

9306

2169

78

10908

8775

1881

59

8586

7758

1476

36

air temp.

12042

9171

1728

49

10314

8532

1476

36

8019

7479

1152

22

28C DB

11421

8973

1404

33

9702

8262

1188

23

7407

7164

909

14

20C WB

10755

9711

1161

22

9045

7974

972

16

6822

6822

729

Cooling capacities are given at high fan speed.


* Nominal capacity

5 - Dimensions
Indoor Unit : HKH-HKW 25 - 35

25
880

35
880

B
C

880
290

880
290

710

710

710

710

6 - Installation
Make sure that the unit is level.
Ensure that the suspension bracket adjustment is such that
there is a 55 mm gap between the underside of the ceiling and
the top of the unit.

Unit installation entails:


- unit mounting
- water piping connections
- condensate water drainage connections
- unit wiring connections.

condensate drain connection

6.1 - Unit clearances

water piping
connections

A minimum of clearance is necessary around the units to ensure proper air circulation and easy access for maintenance.

Clearance required for indoor units


HKH-HKW unit
A

25
300

35
300

Cut the false ceiling materials to the dimensions of the unit.

38
electric cable entry

NOTE : The drainage piping side of the unit must be 3 to 5mm


lower than the other side of the unit.
1500

1500

3 5 mm
Condensate
drain
connection

6.2 Indoor unit installation


Mount the suspension brackets on the suspension rods and
level them with the nuts.
Lift the unit by its mounting brackets.
Place the unit on the suspension brackets, hanging the side
screws in the notches in the bracket. Fit the flat washers, spring
washers and nuts.

Condensate
drain piping
side of the unit.

Tighten all nuts on the suspension rods and unit mounting brackets once all adjustments have been made.

Nut

Washer

38

7 - Condensate Drainage
7.1 - Installation

Insulation
PVC tube
(field supplied).

The units are fitted with an internal condensate drainage pump.


The hose connection point on the unit is located 260 mm above
the level of the false ceiling. Drainage piping connected to the
unit must be installed with a downwards slope without any rises

Pipe clamp

115

260
Rise
!!!

1/25 1/100

260

Drainage piping must be installed with a 1/25 to 1/100 downward


slope and must be clamped.
Insulate the drainage line once it has been connected to the unit.
The drainage line must include an elbow trap (U bend).

Verification of condensate water drainage :


Fill the drain pan and observe evacuation.

7.2 - CAUTION (multiple cassette unit installations)


When a common drainage line is required, the connection point
of each unit to the line must be higher than the line itself. The
diameter of a common drainage line must be sufficient to accomodate the condensate flow from the units connected to it.

8 - Water Piping Connections


Water outlet

115
85

Water inlet

45

condensate drain connection

hanger

C
B

panel

water inlet

water outlet

HKH-HKW 25 170

220

260

1/2

1/2

HKH-HKW 35

220

260

3/4

3/4

170

40

cable entry 30x60

panel

9 - Front Panel Installation


Unpack the front panel and disassemble the grille and filter.
Fix the front panel with four screws to the hook plates provided on
the unit.
Make sure that there is no gap between the mounting surface on
the unit and the front panel. Gaps may cause air leakage and possible condensation.
Take care when installing the long screws in the front panel.
Check the installation height of the unit again (the front panel
should be flush with the ceiling, otherwise air leakage will occur at
the seal between the unt and the front panel).
Once the long screws are inserted and tightened, plug the access
holes with the rubber plugs provided. The outer end of the rubber
plugs is inclined and should be installed flush with the slope. Turn
the plugs to suit their location and press gently into place.

Unit
Air outlet
Hook plate

U-shaped wire

Control box

Cords and
connectors
from air
panel

Indoor unit
Long screw

Lower surface of indoor unit

Rubber plug

38

Air intake grille


Ceiling material
Front panel

Rubber plug

Push gently with thumb

10 - Wiring Diagram
HKH Units
E

2 way valve
Power Supply
220V/1Ph/50Hz

11 - Service and Maintenance


The units are designed to operate for long periods of time with a minimum of maintenance. However, the following operations must be
performed regularly.

COMPONENT
Air filter

MAINTENANCE OPERATIONS
1 - Clean with a vacuum cleaner or tap gently then
wash in warm water (40C) with a mild detergent.

RECOMMENDED
FREQUENCY
Every month or more
often if necessary.

2 - Rinse and dry before replacing on unit.


3 - Never use petrol, alcohol or any other chemical
product.
Unit casing

1 - Remove dust from the front panel with a soft duster


or wipe a damp cloth with a mild soap solution.

Every month or more


often if necessary.

2 - Never use petrol, alcohol or any other chemical


product.
Drain pan and
evacuation piping

1 - Clean and check for obstructions.

Each season before start up.

Coils

1 - Check condition and remove dust from between


coil fins.

Each season before start up.

ALL OTHER SERVICE AND MAINTENANCE OPERATIONS MUST BE PERFORMED


BY TRAINED AND QUALIFIED PERSONNEL APPROVED BY THE SUPPLIER

DE-COMMISSIONING DISMANTLING & DISPOSAL


This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause injury !
All work must only be carried out by competent persons using suitable protective clothing and safety precautions.

Read the Manual

Risk of electric shock

Unit is remotely controlled and


may start without warning

1. Isolate all sources of electrical supply to the unit including any control system supplies switched by the unit. Ensure that all points of electrical and gas
isolation are secured in the OFF position. The supply cables and gas pipework may then be disconnected and removed. For points of connection refer
to unit installation instructions.
2. Remove all refrigerant from each system of the unit into a suitable container using a refrigerant reclaim or recovery unit. This refrigerant may then be
re-used, if appropriate, or returned to the manufacturer for disposal. Under NO circumstances should refrigerant be vented to atmosphere. Where
appropriate, drain the refrigerant oil from each system into a suitable container and dispose of according to local laws and regulations governing disposal of oily wastes.
3. Packaged units can generally be removed in one piece after disconnection as above. Any fixing down bolts should be removed and then the unit lifted
from position using the points provided and equipment of adequate lifting capacity. Reference MUST be made to the unit installation instructions for unit
weight and correct methods of lifting. Note that any residual or spilt refrigerant oil should be mopped up and disposed of as described above.
4. After removal from position the unit parts may be disposed of according to local laws and regulations.

E - TEC - H0002

Europe
YORK INTERNATIONAL
Manufacturer reserves the right to change specifications without prior notice.