Você está na página 1de 5

J120U

Engine JOHN DEERE , 6068TF220


Alternator LEROY SOMER , LSA442S7
<Debut>

120KW GENERATOR
120 KW / 150 KVA DIESEL GENERATOR SET, FULLY PACKAGED:
JOHN DEERE Heavy duty diesel engine, 4 stroke, 1800rpm, Turbo
LEROY SOMER brushless alternator. IP23 protection, Insulation class H
MERLIN GERIN, Main line circuit breaker, wired, maximum output rated
Digital auto-start control panel. CE and UL compliant
Incorporated metallic fuel tank for day use
Auto Start control feature included for interoperation with ATS/AMF
12V charging alternator and 12V DC electric starter motor
12V charged DC starting battery with electrolyte and cables
Dry type air filter, fuel filter and oil filter elements installed
Mechanically welded chassis with vibration isolators
Each unit prototype and individually factory load bank tested
The generator accepts 100% rated load in one step as per NFPA110
and meets ISO8528-5 class G-3 for transient response
Compliant with ISO3046, ISO8528, BS4999, BS5514, BS5000PT99,
AS1359, IEC34, UTE5100, VDE0530 and ISO9001:2000
AVAILABLE ACCESSORIES AND OPTIONS:
Steel or Aluminum weather proof, sound attenuated enclosures
UL142 listed, double wall fuel tanks from 50 to 10,000 Gal
UL1008 listed, automatic transfer switches from 50 to 3000 Amp
D.O.T. compliant heavy duty road trailers from 3000 to 30000 Lbs
Automatic battery chargers, Engine preheaters, Remote annunciators
and many more
Voltage
480/277
440/254
380/220
230/115
220/127
208/120
600/347

Power ESP
kWe/kVA
117 / 146
117 / 146
117 / 146
117 / 146
117 / 146
115 / 144
117 / 146

Power PRP
kWe/kVA
106 / 133
106 / 133
106 / 133
106 / 133
106 / 133
105 / 131
106 / 133

Standby Amps
176
192
222
367
383
400
140

Dimensions - Open

Weight - Open

Leng : 2370mm [93in]


Widt : 1114mm [44in]
Heig : 1480mm [58in]

1570kg [3461lbs] Net


1910kg [4211lbs] Gross

POWER DEFINITION
PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO
8528-1.
ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 85281. Overload is not allowed.

TERM OF USE
Standard reference conditions ESP/PRP 25 C/25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

WEATHER / SOUND PROOF ENCLOSURES


Model

dB(A)@1m

M226-DW

M226

80

80

dB(A)@7m
68.9

68.9

Dimensions - Enclosed
Leng : 3560mm [140in]
Widt : 1200mm [47in]
Heig : 2182mm [86in]
Leng : 3508mm [138in]
Widt : 1200mm [47in]
Heig : 1830mm [72in]

120KW GENERATOR
GENERAL POWER LIMITED, INC

Phone (305) 471 9566, Phone (888) POWER 58, Fax (305) 471 9568, Fax (305) 675 8033
www.dieselgeneratorsmiami.com
www.genpowerusa.com
info@genpowerusa.com
MIAMI, FLORIDA | TUSTIN, CALIFORNIA | PANAMA | FRANCE | COLOMBIA | U.K.

Weight - Enclosed
2560kg [5644lbs]
3443kg [7591lbs]

2160kg [4762lbs]
2500kg [5512lbs]

Tank
868 L
229 Gal

340 L
90 Gal

ENGINE SPECIFICATIONS
Engine model

DATA

GENERAL DATA

Cylinder arrangement
Displacement (C.I.)
Bore (mm) X Stroke (mm)
Compression ratio
Speed (RPM)
Pistons speed (m/s)
Maximum stand-by power at rated RPM (kW)
Frequency regulation (%)
BMEP (bar)
Governor type

JOHN DEERE 6068TF220 , 4-temps, TURBO , N/A


6X
L
6.72
106 X 127
17 : 1
1800
7.62
127
2.5
11.4
MECA

EXHAUST SYSTEM

Exhaust gas temperature (C)


Exhaust gas flow (L/s)
Max. exhaust back pressure (mm CE)

540
413
750

FUEL SYSTEM

Fuel consumption 110% load (gal/hr)


Fuel consumption 100% load (gal/hr)
Fuel consumption 75% (gal/hr)
Fuel consumption 50% (gal/hr)
Maximum fuel pump flow (gal/hr)

9.1
8.4
6.3
4.2
29.5

Oil capacity (L)


Min. oil pressure (bar)
Max. oil pressure (bar)
Oil consumption 100% load (L/h)
Carter oil capacity (L)

21.5
1
5
0.032
20.6

OIL

THERMAL BALANCE

AIR INTAKE

COOLANT SYSTEM

EMISSIONS

GENERAL POWER LIMITED, INC

Heat rejection to exhaust (kW)


Radiated heat to ambiant (kW)
Haet rejection to coolant (kW)

110
16
68

AIR INTAKE_entree_max%
Intake air flow (L/s)

625
179

Radiator & Engine capacity (L)


Max water temperature (C)
Outlet water temperature (C)
Fan power (kW)
Fan air flow w/o restriction (m3/s)
Available restriction on air flow (mm CE)
Type of coolant
Thermostat (C)

27.3
105
93
5
N/A
20
GENCOOL
82-94

Emissions PM (g/kWh)
Emission CO (g/kW.h)
Emissions HCNOx (g/kWh)

N/A
N/A
N/A

Emission HC (g/kW.h)

N/A

Phone (305) 471 9566, Phone (888) POWER 58, Fax (305) 471 9568, Fax (305) 675 8033
www.dieselgeneratorsmiami.com
www.genpowerusa.com
info@genpowerusa.com
MIAMI, FLORIDA | TUSTIN, CALIFORNIA | PANAMA | FRANCE | COLOMBIA | U.K.

ALTERNATOR SPECIFICATIONS

DATA

GENERAL DATA

OTHER

DATA

Alternator brand
Alternator
Number of phase
Power factor (Cos Phi)
Altitude (m)
Overspeed (rpm)
Number of pole
Excitation system
Insulation class / Temperature class
Regulation
Total harmonics TGH/THC
Wave form : NEMA=TIF-TGH/THC
Wave form : CEI=FHT-TGH/THC
Number of bearing
Coupling
Voltage regulation 0 to 100%
Recovery time (Delta U = 20% transitoire) (ms)
Continuous Nominal Rating 40C (kVA)
Standby Rating 27C (kVA)
Efficiencies 4/4 load (%)
Air flow (cfm)
Short circuit ratio (Kcc)
Direct axis synchro reactance unsaturated (Xd) (%)
Quadra axis synchro reactance unsaturated (Xq) (%)
Open circuit time constant (T'do) (ms)
Direct axis transient reactance saturated (X'd) (%)
Short circuit transient time constant (T'd) (ms)
Direct axis subtransient reactance saturated (X''d) (%)
Subtransient time constant (T"d) (ms)
Quadra axis subtransient reactance saturated (X"q) (%)
Zero sequence reactance unsaturated (Xo) (%)
Negative sequence reactance saturated (X2) (%)
Armature time constant (Ta) (ms)
No load excitation current (io) (ms)
Full load excitation current (ic) (A)
Full load excitation voltage (uc) (A)
Recovery time (Delta U = 20% transitoire) (ms)
Motor start (Delta U = 20% perm. or 50% trans.) (ms)
Transient dip (4/4 charge) - PF : 0,8 AR (%)
No load losses (kW)
Heat rejection (kW)

GENERAL POWER LIMITED, INC

Phone (305) 471 9566, Phone (888) POWER 58, Fax (305) 471 9568, Fax (305) 675 8033
www.dieselgeneratorsmiami.com
www.genpowerusa.com
info@genpowerusa.com
MIAMI, FLORIDA | TUSTIN, CALIFORNIA | PANAMA | FRANCE | COLOMBIA | U.K.

LEROY SOMER
LSA442S7
3
0.8
<1000
2250
4
SHUNT
H/H
R230
<2
<50
<2
1
DIRECT
0.5%
500
155
170
91.8
0.44
0.33
363
218
2734
13
100
8
10
9.6
0.7
8.8
15
0.5
1.9
36
500
301
16.6
2.96
10.68

CONTROL PANELS
#STD_COFFRET
Standard

Option

NEXYS
NEXYS
Specifications : Frequency meter, Ammeter, Voltmeter
Alarms and faults : Oil pressure, water temperature, Overcrank,
Overspeed ( >60 kVA), Min/max alternator, Low fuel level,
Emergency stop
Engine parameters : Hours counter, Engine speed, Battery voltage,
Fuel level, AIr preheating

TELYS 2
TELYS
Specifications : Frequency meter, Ammeter, Voltmeter
Alarms and faults : Oil pressure, water temperature, No start-up,
Overspeed, Min/max alternator, Min/max battery voltage, Low fuel
level, Emergency stop
Engine parameters : Hours counter, Oil pressure, Water
temperature, Engine speed, Battery voltage, Fuel level,
Remote monitoring and control

#OPT1#O

ACCESSORIES AND OPTIONS


Option

50 to 3000 AMP Automatic Transfer Switches, UL1008 listed


With a Series 300 transfer switch, you get a product backed by
ASCO Power Technologies, the industry leader
True double-throw operation: single solenoid design is inherently
interlocked & prevents contacts from stopping between sources
Easy-to-read flush-mounted control and display panel provides
LED indicators for switch position and source availability
Standard engine exerciser for weekly automatic testing with or
without load
UL 1008 listed for Transfer Equipment and CSA C22.2 listed
NFPA 110 for Emergency & Standby Power & the National
Electrical (NEC) Articles 700, 701 and 702

PT3
Option

50 to 10000 GAL fuel tanks, UL142 listed


UL listed. Secondary containment tank meeting UL 142 tank
requirements
NFPA compliant. Designed to comply with the installation
standards of NFPA 30 and NFPA 37
Emergency pressure relief vents. Meets UL requirements; ensures
adequate venting of inner and outer tank under extreme pressure
and/or emergency conditions
Electrical stub-up area with removable end channel
Normal vent Inner tank emergency vent sized to UL 142 specs
Direct reading mechanical fuel gauge Fuel in basin switch
Satin black paint finish

#OPT2

GENERAL POWER LIMITED, INC

Phone (305) 471 9566, Phone (888) POWER 58, Fax (305) 471 9568, Fax (305) 675 8033
www.dieselgeneratorsmiami.com
www.genpowerusa.com
info@genpowerusa.com
MIAMI, FLORIDA | TUSTIN, CALIFORNIA | PANAMA | FRANCE | COLOMBIA | U.K.

Weather / Soundproof
Enclosure

M226
STANDARD FEATURES

They protect stationary and mobile generator against the bad weather, against the theft and enables the reduction of
the noise level.
Enclosures are of 12 gauge steel. Steel sheet are electro zinc coated before painting (inside and outside) with a
polyester powder rust inhibiting coat .
High corrosion resistance: stainless covered with zinc and made in dichromate, bolts and rivets, anodized aluminium
alloy hinges flexible seals between body sections.
Soundfoam between 20 and 50 mm (1 to 2 in) acoustical sound treatment
Lifting eye(s) on top of the enclosure fixed to the skid
Large doors allow easy access to the generator set for service and monitoring purposes
Window in securit glass mounted on enclosure door for control viewing .
A critical silencer is mounted inside the enclosure
Emergency stop button is accessible from outside enclosure.

Model

J120U

Dimensions

Weight

Tank

dB(A)@1m

Sound level
dB(A)@7m

LWA

(mm)

(kgs)

(l)

80

68.9

N/A

3508 x 1200 x
1830

2160

340

#OPT3

GENERAL POWER LIMITED, INC

Phone (305) 471 9566, Phone (888) POWER 58, Fax (305) 471 9568, Fax (305) 675 8033
www.dieselgeneratorsmiami.com
www.genpowerusa.com
info@genpowerusa.com
MIAMI, FLORIDA | TUSTIN, CALIFORNIA | PANAMA | FRANCE | COLOMBIA | U.K.

Você também pode gostar