Separation of the solids from the mixed liquor developed in the aeration tank takes
place in the settling compartment. The clarified effluent is withdrawn for reuse or
discharged into a receiving stream from the top of the settling tank. The settled solids
are rapidly pumped from the bottom of the settling tank back to the aeration system.
These Extended Aeration Plants are proven workhorses, providing excellent
Biochemical Oxygen Demand (BOD) and Total Suspended Solids (TSS) removal
efficiencies. Only minimal routine housekeeping and operational tasks are required
of the plant operator.
Key Features
Sample Applications
Economy
Ease of Installation
Simplicity of Operation &
Proven Reliability
Fulfils Regulatory
Requirements
Small Communities
Schools
Hotels and Resorts
Housing Developments
Hospitals
Shopping Malls
Industrial Parks & Factories
Screen (optional)
Oil & grease removal tank (optional)
Equalization tank
Primary settling tank (optional)
Aeration tank
Secondary clarifier
Disinfection tank
Pressure sand filters
Activated carbon filters
Treated water tank
Sludge drying beds or filter press for sludge disposal
SCREEN
1.
2.
3.
4.
5.
6.
7.
Inlet Pipe
Debris
Muck
Grill
Screened Sewage
Outlet Pipe
Platform With Weep Holes
2.
3.
4.
5.
6.
7.
EQUALIZATION TANK
1. Inlet Pipe
2. Sewage
3. Raw Sewage Lift Pumps
(1w + 1s)
4. Delivery Pipe
5. Course Bubble Diffusers
6. Air Supply Pipe Lines
1. Inlet Pipe
2. Center feed well
3. Steeply sloped walls of the
tank
4. Bacterial flocs
5. Sludge pipe
6. Sludge Pumps (1w + 1s)
7. Header Assembly
8. Clear water
9. Launders
10. Clarified water pipe
AERATION TANK
1. Inlet Pipe
2. Baffle Wall
3. Sewage Level (Which is Set
by Top of the Launder
4. Outlet Launder
5. Net (Prevents the Entry of
Debris)
6. Outlet Pipe
7. Fine Bubble Diffusers
8. Header Pipe (Air Supply)
9. Sludge Recirculation Pipe
Chlorine is Dosed in A
Controlled Manner for the
Disinfection of Treated
Water
Separate Dosing Tank
(HDPE) is Provided for
the Chlorine Solution
Disinfected Effluent is
Passed Through PSF And
ACF by Means of Pressure
Pumps
Parameters
pH
Inlet
Characteristics
(Values in mg/lit
except pH)
6.0 8.0
COD
Expected parameters of
wastewater after treatment
Sr. No.
Parameters
pH
Outlet
Characteristics
(Values in mg/lit
except pH)
6.5 8.5
350 - 450
COD
<100
BOD
250 - 350
BOD
<30
SS
150 - 250
SS
<10
10 - 20
<10
* Range mentioned for treated parameters are accepted by MOEF for Gardening and flushing purpose.
BLOCK DIAGRAM
Capital Cost
COSTING
FRP coating
Epoxy paint
Automation
Transportation
Scope of work
Degree of treatment
Running Cost
SPACE REQUIREMENT
Instrumentation
units
Pumps
MCC panel
Pipes
Level Switches
Air Blowers
Cabling
Valves
Flow meters
Filters
Switches
Gates
UV filters
Fabricated water
tanks
Elbows
Dosing pumps
Canopies
Bends
COMPUTERIZED MODEL