(a)
(b)
Q
2
Calculate the diameter and depth of a circular clarifier for a design flow of 3800
m3/d and an overflow rate of 0.00024 m/s and a detention time of 3 h. Calculate
the weir loading rate by assuming the total effluent weir is 20 m.
(5 marks)
The following data were reported on the operation of primary sedimentation tank and
activated sludge system in treating a wastewater
Primary Sedimentation Tank
BOD
Suspended Solid
Influent
150mg/L
275 mg/L
Removal Efficiency
35%
60%
Calculate:
(i)
(ii)
(iii)