Escolar Documentos
Profissional Documentos
Cultura Documentos
FIME
ndice:
INTRODUCCION:............................................................................................. 2
PLANTEAMIENTO DEL PROBLEMA:..................................................................3
OBJETIVOS:..................................................................................................... 3
OBJETIVO GENERAL..................................................................................... 3
OBJETIVOS ESPECIFICOS..........................................................................3
METODOLOGIA............................................................................................... 3
MATERIALES Y EQUIPOS:................................................................................ 4
Elementos secundarios............................................................................ 4
PROCEDIMIENTO DE CLCULO:......................................................................5
RESULTADOS:................................................................................................. 6
AGRUPACIN EN SERIE:.............................................................................. 6
AGRUPACION EN PARALELO.........................................................................8
ENSAYO N 1:........................................................................................... 9
ENSAYO N 2:......................................................................................... 10
DISCUSION:.................................................................................................. 13
CONCLUSIONES:........................................................................................... 13
RECOMENDACIONES:.................................................................................... 14
BIBLIOGRAFIA............................................................................................... 14
INTRODUCCION:
ASOSIACIACION DE BOMBAS
2
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
ASOSIACIACION DE BOMBAS
3
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
OBJETIVOS:
OBJETIVO GENERAL
OBJETIVOS ESPECIFICOS
METODOLOGIA
Encender el panel
de control de la
Bomba con la
valvula
reguladora
totalmente
cerrada.
Verificar que
los
instrumentos
de medida
esten en cero.
Repetir el procedimiento
de variacion de caudal
con otras velocidades
yendo de una mayor a
otra menor, anotar las
lecturas .
MATERIALES Y EQUIPOS:
-
Vacuometro
Manmetro
Motor
Mando y control electrnico
Flujometro
Tacmetro
ASOSIACIACION DE BOMBAS
Poner en funcionamiento
la Bomba con la valvula de
paso abierta al maximo
y ajustar las RPM al
maximo.
4
UNIVERSIDAD NACIONAL DEL CALLAO
Elementos secundarios
o
o
o
o
o
o
o
PROCEDIMIENTO DE CLCULO:
Sabemos:
Z2 Z1 = 0.27m
= 9810 N/m3
D1= 2
D2= 1
P1, P2 (bar),
Q (m3/H)
ASOSIACIACION DE BOMBAS
FIME
5
UNIVERSIDAD NACIONAL DEL CALLAO
2
FIME
P1 V 1
P2 V 2
+
+Z 1 + H B = +
+Z 2 + H P
1 2 g
2 2 g
P2P 1 V 22 V 12
H B=
+
+ ( Z 2 Z 1 ) .. ( I )
2g
Adems:
V
Q 4Q
=
A D 2
V =
16Q 2
D 4
. (II)
N
m2
16Q 2104
1
1
H B=
( P 2P1 ) + 2
4 +( Z 2 Z 1 )
2
4
4
N
36 29.812.54
1.5 2
9810 3
m
105
N
m2
1617.0048 2104
1
1
H B=
( 10.15 ) + 2
4 m+ ( 0.27 m )
2
4
4
N
36 29.812.54
1.5 2
9810 3
m
5
10
H B =9.53270544 m
RESULTADOS:
AGRUPACIN EN SERIE:
Bomba 1 con 3290 rpm
N P1(ba P2(bar Q*
ASOSIACIACION DE BOMBAS
V(voltio A(am
Hb (m)
6
UNIVERSIDAD NACIONAL DEL CALLAO
r)
FIME
(m^3/hr) (m^3/hr) s)
p)
1 -0.6
0.21
6.2
17.0048
200
12
2 -0.4
0.8
5.6
15.2234
200
11
3 -0.49 0.95
4.8
12.8482
200
11
4 -0.3
1.4
10.473
200
10.5
5 -0.2
1.64
3.2
8.0978
200
10
6 -0.1
1.96
2.4
5.7226
200
9.12495
824
12.9817
493
15.2903
27
17.8261
152
19.1619
988
21.3367
138
25
20
21.34
19.16
15
Hb (m)
17.83
15.29
12.98
10
9.12
5
0
4
10
12
14
16
18
Q (m^3/hr)
Q
(m^3/hr)
1 0.15
6.2
17.0048
2 0.7
1.7
5.6
15.2234
3 0.8
2.1
4.8
12.8482
4 1.2
2.75
10.473
5 1.65
6 2
3.5
4
3.2
2.4
8.0978
5.7226
ASOSIACIACION DE BOMBAS
V
(voltios) A (amp) Hb (m)
9.5327054
200
12
4
10.943013
200
11.5
4
13.863211
200
11
8
16.297063
200
10.5
2
19.263935
200
10
6
200
9
20.725093
7
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
25
20
20.73
19.26
15
Hb (m)
16.3
13.86
10
10.94
9.53
5
0
4
10
12
14
16
18
Q (m^3/hr)
45
40
42.13
35
38.12
30
31.59
25
27.01
Hb (m) 20
22.16
15
17.18
10
5
0
4
10
12
Q (m^3/hr)
ASOSIACIACION DE BOMBAS
14
16
18
8
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
AGRUPACION EN PARALELO
TOMAMOS DATOS PARA DOS ENSAYOS, DE LOS CUALES NOS
ENFOCAREMOS EN EL SEGUNDO, PUESTO QUE NOTAMOS QUE
OBTENDREMOS ALTURAS NETAS SIMILARESPARA AMBAS BOMBAS (Hb)
Y ESTO NOS FACILITARA EL CLCULO:
ASOSIACIACION DE BOMBAS
9
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
ENSAYO N 1:
Bomba 1 con 3100 rpm
P1
N (bar)
P2
(bar) Q (LPM)
Q
(m^3/hr)
V
A
(voltios) (amperios)
1 -0.2
1.25
220
13.2
190
10
2 -0.2
1.4
190
11.4
198
3 -0.08
1.65
155
9.3
198
4 -0.08
1.7
130
7.8
198
5 -0.05 1.8
6 0.025 1.9
100
198
80
4.8
198
Hb (m)
15.411217
2
16.848684
7
18.083953
9
18.540585
9
19.202766
8
19.940487
6
25
20
15
10
5
0
60
80
100
120
140
160
180
200
220
240
V
A
Q (m^3/hr) (voltios) (amperios)
1 -0.1
1.2
3.6
9.2854
200
11
2 -0.05
3 -0.12
1.5
1.7
2.6
2.2
6.3164
5.1288
200
200
11
10.5
ASOSIACIACION DE BOMBAS
Hb (m)
13.70011
03
16.15272
28
18.87690
10
UNIVERSIDAD NACIONAL DEL CALLAO
4 -0.01
2.1
5 -0.01 2.3
6 0.001 2.4
FIME
4.535
200
9.5
1.8
3.9412
200
1.4
2.7536
200
8.5
33
21.82120
18
23.84952
77
24.76070
8
30
25
20
15
10
5
0
2
10
ENSAYO N 2:
Bomba 1 con 3180 rpm
P1
P2
Q
N (bar)
(bar)
(LPM)
Q
(m^3/hr)
V
A
(voltios) (amperios)
1 -0.2
1.1
210
12.6
185
8.5
2 -0.15
1.2
180
10.8
182
8.5
3 -0.1
1.38
160
9.6
182
4 -0.09
1.48
130
7.8
180
5 -0.02
1.6
100
185
7.9
80
4.8
182
7.9
6 -0.0009 1.7
ASOSIACIACION DE BOMBAS
Hb (m)
13.850147
9
14.272714
9
15.547261
2
16.399913
1
16.858220
4
17.656083
9
11
UNIVERSIDAD NACIONAL DEL CALLAO
20
17.66
18
FIME
16.86
16.4
16
14.27
15.55
14
13.85
12
Hb (m)
10
8
6
4
2
0
4
10
11
12
13
14
Q (m^3/hr)
Q
(m^3/hr)
V
A
(voltios) (amperios)
1 -0.1
1.05
4.5
11.9575
180
9.5
2 -0.09
1.2
10.473
180
3 -0.05
1.35
3.5
8.9885
180
4 -0.01
1.5
7.504
180
8.5
2.5
6.0195
180
4.535
180
5 -0.01 1.65
6 0.001 1.8
ASOSIACIACION DE BOMBAS
Hb (m)
12.28846
18
13.64670
64
14.70825
67
15.77892
29
17.26645
24
18.67135
47
12
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
20
18
18.67
16
17.27
15.78
14
14.71
13.65
12
Hb (m)
12.29
10
8
6
4
2
0
4
10
11
12
13
Q (m^3/hr)
N
1
2
3
4
5
6
Hb
prom
(m)
13.0693048
2
13.9597106
5
15.1277589
3
16.0894180
1
17.0623364
18.1637193
2
Q1
+
(m^3/hr)
Q2
24.5575
21.273
18.5885
15.304
12.0195
9.335
ASOSIACIACION DE BOMBAS
13
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
30
25
24.56
21.27
20
Hb (m)
18.59
15.3
15
12.02
10
9.34
5
0
12
13
14
15
16
17
18
19
Q (m^3/hr)
ASOSIACIACION DE BOMBAS
14
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
DISCUSION:
En la toma de datos en el laboratorio la bomba 2 arrojaba datos, que
faltaban ser convertidos. Ya q no estaba calibrada. En la toma de llaves en la
medicin de las presiones, la precisin de la toma de datos no fu tan buena
CONCLUSIONES:
ASOSIACIACION DE BOMBAS
15
UNIVERSIDAD NACIONAL DEL CALLAO
FIME
RECOMENDACIONES:
BIBLIOGRAFIA
http://es.slideshare.net/MonicaLopez2/bombas-centrifugas-en-serie-yparalelo
GUIA DE LAB DE ENERGIA I
ASOSIACIACION DE BOMBAS