Você está na página 1de 254

PC-0003 Rev F

MEMS Pressure Sensors


PDF Catalog

Table of Contents
Help me Choose
Product Matrix

Section

0-1

Evaluation Kit

Section

0-2

ADCX Series Pressure Sensors (DS-0091)

Section

1-1

MLV Series Pressure Sensors (DS-0274)

Section

1-2

XHM Series (DS-0333)

Section

1-3

CPM 502 Series (DS-0347)

Section

1-4

CPM 602 Series (DS-0348)

Section

1-5

AXCX Series Low Pressure Sensors (DS-0090)

Section

1-6

AXCX Series C-Grade Pressure Sensors (DS-0094)

Section

1-7

AXCX Series H-Grade Pressure Sensors (DS-0095)

Section

1-8

AXCX Series Prime Grade Pressure Sensors (DS-0096)

Section

1-9

MDCX Series Miniature Low Pressure Sensors (DS-0108)

Section

1-10

Special Series Blood Pressure Millivolt Output Pressure Sensors (DS-0048)

Section

1-11

ACPC Series C-Grade Pressure Sensors (DS-0106)

Section

1-12

ACPC Series H-Grade Pressure Sensors (DS-0107)

Section

1-13

ACPC Series Prime Grade Pressure Sensors (DS-0110)

Section

1-14

ACPC Series Barometric Pressure Sensors (DS-0039)

Section

1-15

Millivolt Output (compensated)

Table of Contents
Digital Output
DLVR Series Pressure Sensors (DS-0300)

Section

2-1

DLV Series Pressure Sensors (DS-0336)

Section

2-2

FPS Series Pressure Sensors (DS-0329)

Section

2-3

ADO Series Digital Output Pressure Sensors (DS-0012)

Section

2-4

ADO Series Mil Spec Digital Pressure Sensors (DS-0009)

Section

2-5

ADO Series Barometric Digital Pressure Sensors (DS-0010)

Section

2-6

ADO Series Mil Spec Barometric Digital Pressure Sensors (DS-0011)

Section

2-7

CPA 502 Series (DS-0339)

Section

3-1

CPA 602 Series (DS-0340)

Section

3-2

ADCA Series Amplified Very Low Pressure Sensors (DS-0032)

Section

3-3

ADCA Series Amplified Low Pressure Sensors (DS-0024)

Section

3-4

ADCA Series Industrial Grade Amplified Pressure Sensors (DS-0025)

Section

3-5

ADCA Series Mil Spec Amplified Pressure Sensors (DS-0026)

Section

3-6

AXCA Series Amplified Middle Pressure Sensors (DS-0028)

Section

3-7

AXCA Series Prime Grade Amplified Middle Pressure Sensors (DS-0029)

Section

3-8

AXCA Series Mil Spec Amplified Middle Pressure Sensors (DS-0031)

Section

3-9

ASCX Series Compatible Amplified Pressure Sensors (DS-0023)

Section

3-10

MAMP Series Pressure Sensors (DS-0101)

Section

3-11

MAMP Series Prime Grade Pressure Sensors (DS-0102)

Section

3-12

SAMP Series Pressure Sensors (DS-0103)

Section

3-13

SAMP Series Barometric Pressure Sensors (DS-0040)

Section

3-14

AXCA Series Barometric Pressure Sensors (DS-0041)

Section

3-15

MAMP Series Medical Breathing Pressure Sensors (DS-0097)

Section

3-16

Special Series Respiratory Amplified Pressure Sensors (DS-0027)

Section

3-17

Amplified Output

Table of Contents
Basic Output (uncompensated)
BLV Series Pressure Sensors (DS-0275)

Section

4-1

BLVR Series Pressure Sensors (DS-0280)

Section

4-2

CSM Series Pressure Sensors (DS-0165)

Section

4-3

XHB Series (DS-0335)

Section

4-4

ADUX Series Pressure Sensors (DS-0105)

Section

4-5

BDS Series Pressure Sensors (DS-0266)

Section

4-6

A-Package

Section

5-1

E-Package, P-Package

Section

5-2

M-Package

Section

5-3

C-Package

Section

5-4

B-Package

Section

5-5

L-Package, N-Package, FA-Package

Section

5-6

FB-Package, FK-Package

Section

5-7

Definition of Terms

Section

6-1

Pressure Unit Conversation Constants Chart

Section

6-2

Appendix A: Packaging

Appendix B: Additional Resources

Product Matrix
Device
Family

Datasheet

Pressure Range
US Customary

Pressure Range
Metric

Grade

Compensated
Temperature Range C

Output

Measurement
Type

Package
Series

Media
Compatibility

Housing
Material

ADCX

DS-0091

0.5 to 30 inH2O

1 to 75 mbar

0 to 50 (70)

mV

MLV

DS-0274

1 inH2O to 150 PSI

2.5 to 10.5 bar

0 to 50

mV

D, A

A, E

DS-0090

2 to 30 inH2O

5 to 75 mbar

0 to 50 (70)

mV

AXCX

MDCX

Special

DS-0094

4 inH2O to 150 PSI

10 mbar to 10.5 bar

0 to 70

mV

D, A

DS-0095

4 inH2O to 150 PSI

10 mbar to 10.5 bar

0 to 70

mV

D, A

DS-0096

0.3 to 150 PSI

20 mbar to 10.5 bar

0 to 70

mV

D, A

DS-0108

2 to 30 inH2O

5 to 75 mbar

0 to 50 (70)

mV

D, G

DS-0048

160.5 inH2O

300 mmHg

10 to 50

mV, 4V

D, G

A, M

DS-0027

47 inH2O

120 cmH2O

5 (-25) to 50 (85)

4V

DS-0039

8.5 to 16 PSI

600 to 1100 mbar

0 to 70

mV

DS-0106

4 inH2O to 100 PSI

10 mbar to 7 bar

0 to 70

mV

D, A, G

DS-0107

4 inH2O to 100 PSI

10 mbar to 7 bar

0 to 50 (70)

mV

D, A, G

DS-0110

0.3 to 100 PSI

20 mbar to 7 bar

0 to 70

mV

D, A, G

DS-0039

8.5 to 16 PSI

600 to 1100 mbar

0 to 70

mV

DLVR

DS-0300

0.5 to 60 inH2O

1.2 to 150 mbar

0 (-20) to 70 (85)

Digital

D, G

FPS

DS-0329

0.1 to 2 inH2O

0.25 to 5 mbar

0 to 70

Digital, mV

D, G

ACPC

ADO

ADCA

AXCA

MAMP

SAMP

DS-0012

5 inH2O to 100 PSI

12.5 mbar to 7 bar

-20 to 85

Digital

D, A

DS-0009

5 inH20 to 100 PSI

12.5 mbar to 7 bar

-40 to 125

Digital

D, A

DS-0010

8.5 to 16 PSI

600 to 1100 mbar

-20 to 85

Digital

DS-0011

8.5 to 16 PSI

600 to 1100 mbar

-40 to 125

Digital

DS-0032

0.25 to 0.5 inH2O

0.6 to 1.2 mbar

5 to 50

4V

D, G

DS-0024

0.4 to 60 inH2O

1 to 150 mbar

5 to 50

4V

D, G

DS-0025

0.4 to 30 inH2O

1 to 75 mbar

-25 to 85

4V

D, G

DS-0026

0.4 to 30 inH2O

1 to 75 mbar

-40 to 125

4V

D, G

DS-0028

0.3 to 150 PSI

20 mbar to 10.5 bar

5 to 50

4V

D, A, G

DS-0029

0.3 to 100 PSI

20 mbar to 7 bar

-25 to 85

4V

D, A, G

DS-0031

0.3 to 15 PSI

20 mbar to 1 bar

-40 to 125

4V

D, A, G

DS-0023

1 to 100 PSI

68 mbar to 7 bar

0 to 70

4V

D, A

DS-0101

0.5 to 30 inH2O

1.2 to 75 mbar

5 to 50

4V

D, G

DS-0102

1 to 60 inH2O

2.5 to 150 mbar

-25 to 85

4V

D, G

DS-0097

5 to 120 cmH2O

5 to 117.5 mbar

5 (-25) to 50 (85)

4V

DS-0103

0.3 to 30 PSI

20 mbar to 2 bar

5 to 50

4V

D, A, G

DS-0040

8.5 to 16 PSI

600 to 1100 mbar

S/P/M

Special

4V

AXCA

DS-0041

8.5 to 16 PSI

600 to 1100 mbar

S/P/M

Special

4V

BLV

DS-0275

1 to 30 inH2O

2.5 to 75 mbar

Uncompensated

mV

BLVR

DS-0280

1 to 30 inH2O

2.5 to 75 mbar

Uncompensated

mV

CSM

DS-0165

5 inH2O to 100 PSI

12.5 mbar to 7 bar

Uncompensated

mV

G, A

ADUX

DS-0105

1 to 30 inH2O

2.5 to 75 mbar

0 to 70

mV

G, A

Measurement Units
(Pressure Range)

n Red
n Black

Specified
Converted

Package Series

Grade
SStandard
C
C-Grade, Good
H
H-Grade, Better
P
P-Grade, Best
MMilitary

Output
mVMillivolt
DigitalDigital
4VAmplified

Measurement Type
DDifferential
AAbsolute
GGauge

Housing
P Plastic

Media Compatibility
1
Non-Corrosive, Non-Condensing Dry Air and Gas

0-1

Summary: Sensor Evaluation Kit EK-01


General description
Sensor Type
Measurement
Data Display
Driver
Lab test equipment
Price

Easily evaluate Analog and Digital Sensors


ZF socket allows instant electrical connection
Analog, Digital
Display data from Digital parts in convenient units
Choice of 12 units of measurement
Capture data from Digital parts to CSV text le
Includes sample index and timestamp
Uses standard Windows in-box USB drivers
No separate download or CD needed
Standard terminals for Lab test equipment
Dual 4mm "banana" binding posts
$150 (globally)
Includes: evaluation board, software, 1 adapter of choice, USB

List of supported ASC product series and required


adapters.
EK-01 Product Series Adapter Cross Reference
Series
Adapter
ACPC
ANA-02
ADCA
ANA-04
ADCX
ANA-01
ADUX
ANA-03
ASCX
ANA-05
AXCA
ANA-04
AXCX
ANA-01
BLV
ANA-03
BLVR
ANA-03
DLV
DIG-01
DLVR
DIG-01
FPS
DIG-02
MAMP
ANA-06
MCI (DIP)
DIG-06
MCI (SIP)
DIG-04
MCS
DIG-05
MDCX
ANA-02
MLV (A Pkg)
ANA-01
MLV (E Pkg)
ANA-02
SAMP
ANA-06
XHI
DIG-03

0-2

Millivolt Output

Millivolt Output Pressure Sensors


Low Pressure (0.5 H2O to 30 H2O) Sensors

Features

all sensors

0 to 0.5 H2O to 0 to 30 H2O Pressure Ranges


Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
HVAC

The Millivolt Output pressure sensor is based upon a proprietary technology to reduce all output offset or common mode errors.
This model provides a calibrated millivolt output with superior output offset characteristics. Output offset errors due to change in
temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared
to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced
structure to provide a very linear output to measured pressure.

e www.allsensors.com

General Description

Physical Dimensions

p 408 225 4314

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +16 V is acceptable.

Equivalent Circuit

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

+Vs upply

-Vout

+Vout

Pin 1: N/C
Pin 2: +V supply
Pin 3: +Voutput

-Vs upply

Pin 4: -Vsupply
Pin 5: -Voutput
Pin 6: N/C

Input Resittance

4.5 k ohm

Output Resistance

1.5 k ohm

Approvals
MKT

As Is

DATE

With Change

All Sensors

MFG

As Is

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

f 408 225 2079

These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This
series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

DATE

With Change

DS-0091 Rev C
1-1

Pressure Sensor Ratings

Environmental Specifications
16 Vdc

Supply Voltage Vs, max

-10 to +10 psig

Common-mode pressure

270C

Lead Temperature, max


(soldering 2-4 sec.)

Temperature Ranges
Compensated

0 to 50(70) C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

0 - 0.5 H2O

10mV

100 H2O

200 H2O

1 INCH-D-MV

0 - 1 H2O

10 mV

100 H2O

200 H2O

2 INCH-D-MV

0 - 2 H2O

10mv

100 H2O

200 H2O

5 INCH-D-MV

0 - 5 H2O

20 mV

200 H2O

300 H2O

10 INCH-D-MV

0 - 10 H2O

20 mV

200 H2O

300 H2O

20 INCH-D-MV

0 - 20 H2O

20 mV

200 H2O

500 H2O

30 INCH-D-MV

0 - 30 H2O

20 mV

200 H2O

800 H2O

0.5 INCH-D-MV

Performance Characteristics for 0.5 INCH-D-MV


Minimum

Nominal

Maximum

Units

--

0 .5

--

H2O

9.0

10.0

11.0

mV

Offset Voltage @ zero differential pressure

--

--

500

uV

Offset Temperature Shift (0C-50C), note 2

--

--

250

uV

Offset Warm-up Shift, note 3

--

--

100

uV

Offset Position Sensitivity (1g)

--

--

5.0

uV

Offset Long Term Drift (one year)

--

--

200

uV

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Full Scale Shift (0C-50C), note 2

--

--

200

uV

Minimum

Nominal

Maximum

Units

--

1 .0

--

H2O

9.0

10.0

11.0

mV

Offset Voltage @ zero differential pressure

--

--

500

uV

Offset Temperature Shift (0C-50C), note 2

--

--

250

uV

Offset Warm-up Shift, note 3

--

--

100

uV

Offset Position Sensitivity (1g)

--

--

50

uV

Offset Long Term Drift (one year)

--

--

200

uV

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Full Scale Shift (0C-50C), note 2

--

--

200

uV

Parameter, note 1
Operating Range, differential pressure
Output Span, @ 0.5H2O, note 5

Performance Characteristics for 1 INCH-D-MV


Parameter, note 1
Operating Range, differential pressure
Output Span, @ 1H2O, note 5

Millivolt Low pressure sensors


1-1

Nominal

Maximum

Units

--

2.0

--

H2O

9.0

10.0

11.0

mV

Offset Voltage @ zero differential pressure

--

--

500

uV

Offset Temperature Shift (0C-50C), note 2

--

--

250

uV

Offset Warm-up Shift, note 3

--

--

100

uV

Offset Position Sensitivity (1g)

--

--

50

uV

Offset Long Term Drift (one year)

--

--

200

uV

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Full Scale Shift (0C-50C), note 2

--

--

200

uV

Minimum

Nominal

Maximum

Units

--

5.0

--

H2O

19.0

20.0

21.0

mV

Offset Voltage @ zero differential pressure

--

--

500

uV

Offset Temperature Shift (0C-50C), note 2

--

--

150

uV

Offset Warm-up Shift, note 3

--

--

50

uV

Offset Position Sensitivity (1g)

--

--

10

uV

Offset Long Term Drift (one year)

--

--

100

uV

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Full Scale Shift (0C-50C), note 2

--

--

200

uV

Minimum

Nominal

Maximum

Units

--

10.0

--

H2O

19.0

20.0

21.0

mV

Offset Voltage @ zero differential pressure

--

--

500

uV

Offset Temperature Shift (0C-70C), note 2

--

--

150

uV

Offset Warm-up Shift, note 3

--

--

50

uV

Offset Position Sensitivity (1g)

--

--

uV

Offset Long Term Drift (one year)

--

--

100

uV

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Full Scale Shift (0C-70C), note 2

--

--

200

uV

Operating Range, differential pressure


Output Span, note 5

e www.allsensors.com

Minimum

Parameter, note 1

all sensors

Performance Characteristics for 2 INCH-D-MV

Output Span, note 5

p 408 225 4314

Operating Range, differential pressure

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

f 408 225 2079

Performance Characteristics for 5 INCH-D-MV

Performance Characteristics for 10 INCH-D-MV


Parameter, note 1
Operating Range, differential pressure
Output Span, note 5

All Sensors

DS-0091 Rev C
1-1

Performance Characteristics for 20 INCH-D-MV


Parameter, note 1

Minimum

Nominal

Maximum

Units

--

20.0

--

H2O

19.0

20.0

21.0

mV

Offset Voltage @ zero differential pressure

--

--

500

uV

Offset Temperature Shift (0C-70C), note 2

--

--

150

uV

Offset Warm-up Shift, note 3

--

--

50

uV

Offset Position Sensitivity (1g)

--

--

uV

Offset Long Term Drift (one year)

--

--

100

uV

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Full Scale Shift (0C-70C), note 2

--

--

200

uV

Minimum

Nominal

Maximum

Units

--

30.0

--

H2O

19.0

20.0

21.0

mV

Offset Voltage @ zero differential pressure

--

--

500

uV

Offset Temperature Shift (0C-70C), note 2

--

--

150

uV

Offset Warm-up Shift, note 3

--

--

50

uV

Offset Position Sensitivity (1g)

--

--

uV

Offset Long Term Drift (one year)

--

--

100

uV

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Full Scale Shift (0C-70C), note 2

--

--

200

uV

Operating Range, differential pressure


Output Span, note 5

Performance Characteristics for 30 INCH-D-MV


Parameter, note 1
Operating Range, differential pressure
Output Span, note 5

Specification Notes
1: ALL PARAMETERS ARE MEASURED AT 12.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE.
NOTE

OTHERWISE SPECIFIED.

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of
any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Millivolt Low pressure sensors


1-1

MLV Series Low Voltage Pressure Sensors


Features
1 to 30 inH2O & 5 to 150 PSI Pressure Ranges
5V Operation
High Output
Low Power Consumption
Excellent Position Sensitivity
Low Warm-Up Shift
Enhanced Front to Back Linearity
Protective Parylene Coating Option

Applications

General Description

all sensors

Medical Breathing
Environmental Controls
HVAC
Industrial Controls
Portable/Hand-Held Equipment

e www.allsensors.com

The MLV Series Compensated Sensor is based on All Sensors CoBeam2 TM Technology *. The device provides a high output signal at a
low operating voltage while maintaining comparable output levels to traditional equivalent compensated millivolt sensors operating at higher voltages. This lower supply voltage gives rise to improved warm-up shift while the CoBeam2 Technology itself reduces
package stress susceptibility resulting in improved overall long term stability. The technology also vastly improves position sensitivity
compared to conventional single die devices.

Standard Pressure Ranges

Equivalent Circuit

Proof Pressure

Burst Pressure

Nominal Span

MLV-L01D

1 inH2O

100 inH2O

300 inH2O

7 mV

MLV-L02D

2 inH2O

100 inH2O

300 inH2O

10 mV

MLV-L05D

5 inH2O

200 inH2O

300 inH2O

15 mV

MLV-L10D

10 inH2O

200 inH2O

300 inH2O

20 mV

MLV-L20D

20 inH2O

200 inH2O

500 inH2O

20 mV

MLV-L30D

30 inH2O

200 inH2O

800 inH2O

20 mV

MLV-005D

5 PSI

10 PSI

30PSI

25 mV

MLV-015D

15 PSI

60 PSI

120 PSI

37.5 mV

MLV-015A

0 - 15 PSIA

60 PSI

120 PSI

37.5 mV

MLV-030D

30 PSI

90 PSI

150 PSI

37.5 mV

MLV-100D

100 PSI

200 PSI

250 PSI

37.5 mV

MLV-150D

150 PSI

200 PSI

250 PSI

37.5 mV

+Vsupply

-Vout

p 408 225 4314

Operating Range

+Vout

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Device

f 408 225 2079

These calibrated and compensated sensors give an acurate and stable output over a wide temperature range. This series is
intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. A protective parylene coating
is optionally available for moisture/harsh media protection. The output is also ratiometric to the suply voltage and designed to
operate at 5.0 volts DC.

-Vsupply

Approvals
MKT

As Is

DATE

With Change

MFG

As Is

All Sensors

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0274 Rev B
1-2

Pressure Sensor Maximum Ratings


Supply Voltage (Vs)

Environmental Specifications

12 Vdc

Common Mode Pressure


InH2O Devices (L01, L02, L05, L10, L20, L30)

10 psig

PSI Devices (005, 015, 030, 100, 150)

50 psig

Lead Temperature (soldering 2-4 sec.)

270 C

Temperature Ranges
Compensated
Operating
Storage

0C to 50C
-25C to 85 C
-40C to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Performance Characteristics for MLV Series (InH2O)

All parameters are measured at 5.0 volt excitation and room temperature unless otherwise specified. Pressure measurements are with positive
pressure applied to PORT B (the only port for the single port configuration packages).

Parameter

Min

Typ

Max

Units

Notes

Output Span
L01D @ 1 inH2O
L02D @ 2 inH2O
L05D @ 5 inH2O
L10D @ 10 inH2O
L20D @ 20 inH2O
L30D @ 30 inH2O

6.0
9.0
14.0
19.0
19.0
19.0

7.0
10.0
15.0
20.0
20.0
20.0

8.0
11.0
16.0
21.0
21.0
21.0

mV
mV
mV
mV
mV
mV

4
4
4
4
4
4

Span Temperature Shift (0C to 50C)

250

uV

Offset Voltage @ Zero Diff. Pressure

500

uV

Offset Temperature Shift (0C to 50C)


L01D, L02D, L05D

250

uV

L10D, L20D, L30D

200

uV

Offset Warm-up Shift

50.0

uV

L01D

20.0

uV

L02D

15.0

uV

L05D, L10D, L20D, L30D

10.0

uV

Offset Position Sensitivity (1g)

Offset Long Term Drift (One Year)


L01D, L02D, L05D

150

uV

L10D, L20D, L30D

100

uV

Linearity, Hysteresis Error

0.10

0.30

%FSS

Response Time (10% to 90% Pressure Response)

500

us

Front to Back Linearity

0.75

%FSS

Input Resistance

12.0

k ohm

Output Resistance

3.0

k ohm

MLV Series Low Voltage Pressure Sensors


1-2

Performance Characteristics for MLV Series (PSI)

All parameters are measured at 5.0 volt excitation and room temperature unless otherwise specified. Pressure measurements are with positive pressure applied
to PORT B (the only port for the single port configuration packages).

Parameter

Min

Typ

Max

Units

Notes

24.0
36.5
36.5
36.5
36.5
36.5

25.0
37.5
37.5
37.5
37.5
37.5

26.0
38.5
38.5
38.5
38.5
38.5

mV
mV
mV
mV
mV
mV

4
4
4
4
4
4

Span Temperature Shift (0C to 50C)

1.0

mV

Offset Voltage @ Zero Diff. Pressure

300

uV

Offset Temperature Shift (0C to 50C)

300

uV

Offset Warm-Up Shift

50

uV

Offset Long Term Draft (one year)

100

uV

Linearity, Hysteresis Error

0.20

0.50

%FSS

Response Time (10% to 90% Pressure Response)

500

us

Front to Back Linearity

0.75

%FSS

Input Resistance

12.0

k ohm

Output Resistance

3.0

k ohm

e www.allsensors.com

005D @ 5 PSI
015D @ 15 PSI
015A @ 15 PSIA
030D @ 30 PSI
100D @ 100 PSI
150D @ 150 PSI

all sensors

Output Span

f 408 225 2079

Specification Notes
note 1: Shift is relative to 25C.
note 2: Shift is within the first hour of excitation applied to the device.
note 3: Measured at one-half full scale rated pressure using best straight line curve fit.
note 4: The span is the algebraic difference between full scale output voltage and the offset voltage.

note

6: Parameter is characterized and not 100% tested.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

5: Front-Back Linerity computed as: Lin FB

p 408 225 4314

Span Front

1 100%

Span Back

note

All Sensors

DS-0274 Rev B
1-2

How To Order

A Package
Example: MLV-L02D-A6BBF-N

MLV-

Series

Pressure Range

-A6

Coating
Op on

L01D

1 i nH2O

L02D

2 i nH2O

Op on

L05D

5 i nH2O

No Port Cut

L10D

10 in H2O

Two Ports Cut 0.085"

L20D

20 in H2O

Two Ports Cut 0.100"

De sc rip on

L30D

30 in H2O

Two Ports Cut 0.150"

005 D

5 PSI

One Port (A) Cut 0.080"

015 D

15 PSI

One Port (A) Cut 0.370"

015 A

15 PSIA

030 D

30 PSI

100 D

100 PSI

150 D

150 PSI

No Coa ng

Paryle ne Coa ng

(See NOTE 1 below)

Port Fittings
Op on

De sc rip on

De sc rip on

No Fi ngs

Ba rb Fi ng Port A Only

Ba rb Fi ng Port B Only

Ba rb Fi ngs Ports A & B

Op on
F

De sc rip on
Fl at (Straig ht)

Ri ght Angl e 0.075"

Rig ht Angle 0.100"

Jogge d Be nd

E Package
Example: MLV-L02D-E1ND-N

MLV-

-E

Series
Pressure Range

Coating
Op on

Port Orientation
L01D

1 i nH2O

Op on

L02D

2 i nH2O

Du al Port Sam e Si de

L05D

5 i nH2O

Du al Port Oppo si te Sid e

L10D

10 in H2O

20 in H2O

Si ngle Port (Gag e)

L20D
L30D

30 in H2O

Lid Style

005 D

5 PSI

Op on

015 D

15 PSI

NN

Non-Barbed
on -Barbe d

015 A

15 PSIA

BB

Barbed
arbe d

030 D

30 PSI

De sc rip on

De sc rip on

No Coa ng

Paryle ne Coa ng

Lead Type
Op on
SS

De sc rip on

De sc rip on
SIP
IP

DD

DIP
IP

JJ

J-Lead
-Lea
d SMT
SMT

LL

Low
Profile
leDIP
DIP
ow Pro

TABLE 1: Available E-Series Package Configurations


Non-Barbed Lid
Lead Style

Port
SIP

DIP

Barbed Lid
Lead Style

J Lead SMT

Dual Port
Same Side

SIP

DIP

N/A

E1NS

E1ND

E1NJ

Dual Port
Opposite
Side

E1BS

E2ND

E2NJ

EGNS

EGND

EGNJ

N/A

N/A

N/A

N/A

EGBJ

EGBL

E1BD

N/A

E2NS

J Lead SMT

E2BS

E2BD

EGBS

EGBD

Single Port
(Gage)

EGNL

NOTE 1) Parylene Coating: Parylene coating provides a moisture barrier and protection from some harsh media. Consult factory for applicability of Parylene for the target application and sensor type.

MLV Series Low Voltage Pressure Sensors


1-2

Package Drawings
A6 Package (Without Options)

Pinout

1) N/C
2) Vs
3) +Out
4) Gnd
5) -Out
6) N/C

21.59
0.850
20.32
0.800

all sensors

5.33
0.210

10.67
0.420

Port B

10.67
0.420

27.43
1.080

4.81
0.189

2.40
0.094

4.42
0.174

3.56
0.140

Port A
[6.35]
0.250 (min)

0.25
0.010
8.74
0.344

Pin 1
Identifier

0.51
0.020

3.81
0.150
1.27
0.050

e www.allsensors.com

13.97
0.550

3.18
0.125

12.19
0.480

2.54
0.100

NOTES
1) Dimensions are in inches [mm].
2) For suggested pad layout,
see drawing: PAD-09

f 408 225 2079

Example: MLV-L10D-A6xAF-N

A-Package: Port Cut Options

A- No Port Cut Configuration

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

E- Port A cut 0.080" Configuration


4.50
0.177
9.40
0.370

2.54
0.100

B- Two Ports Cut 0.085" Configuration


4.74
0.187

4.76
0.187

2.03
0.080

D- Two Ports Cut 0.150" Configuration


2.16
0.085

4.75
0.187

p 408 225 4314

4.69
0.185

3.81
0.150

Port Cut Options

C- Two Ports Cut 0.100" Configuration

All Sensors

F- Port A Cut 0.370" Configuration

DS-0274 Rev B
1-2

Example: MLV-L10D-A6DxF-N

A-Package: Port Fitting Options

Port Fitting Options


1.13
0.045

4.75
0.187

A- No Fittings Configuration

2.37
0.093

1.20
0.047

NOTE: Port Cut Configuration "D" Shown As Reference.

2.06
0.081

C- Barb Fitting Port B Only Configuration

B- Barb Fitting Port A Only Configuration

1.13
0.045

2.37
0.093

4.73
0.186

2.06
0.081

4.71
0.185

2.06
0.081

2.37
0.093

1.24
0.049
1.12
0.044

1.20
0.047

D- Barb Fitting Ports A and B Configuration

Example: MLV-L10D-A6AAx-N

A-Package: Lead Bend Options

F- Flat (Straight) Configuration

R- Right Angle 0.100" Configuration

[2.60]
0.100

2.06
0.081

J- Jogged Bend Configuration

0.25
0.010

3.45
0.136

[5.72]
0.225 (min)

[4.70]
0.185

Q- Right Angle 0.075" Configuration

[3.81]
0.150 (min)

0.25
0.010

[4.45]
0.175 (min)

[6.35]
0.250 (min)

3.45
0.136

3.45
0.136

0.25
0.010

Lead Bend Options

0.25
0.010
[1.88]
0.075

MLV Series Low Voltage Pressure Sensors


1-2

E1NS Package

Pinout
1) Gnd
2) +Out
3) Vs
4) -Out

7.17
0.282

12.70
0.500

4.88
0.192

0.64
0.025

10.79
0.425

2.10
0.082

0.25
0.010

all sensors

2.04
0.080

10.79
0.425

Port A

2.73
0.107

[9.65]
0.380 (nom)

6.45
0.254

9.80
0.386

15.75
0.620

Port B

0.51
0.020

2.54
0.100

e www.allsensors.com

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

E1BS Package

Pinout

0.51
0.020

p 408 225 4314

Port A

2.73
0.107

[9.65]
0.380 (nom)
0.25
0.010

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

1.68
0.066

10.80
0.425

Port B

6.45
0.254

9.80
0.386

1.14
0.045

10.80
0.425

15.75
0.620

0.64
0.025

2.11
0.083

12.70
0.500

4.88
0.192

2.24
0.088

9.15
0.360

f 408 225 2079

1) Gnd
2) +Out
3) Vs
4) -Out

2.54
0.100

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

All Sensors

DS-0274 Rev B
1-2

E2NS Package

Pinout
1) Gnd
2) +Out
3) Vs
4) -Out

7.17
0.282

0.64
0.025
2.12
0.084

12.70
0.500
10.79
0.425

Port A

2.10
0.082

2.04
0.080

10.79
0.425
2.73
0.107

[9.65]
0.380 (nom)

9.80
0.386

15.75
0.620

Port B

0.25
0.010

2.54
0.100

0.51
0.020

Pin 1 2 3 4

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

E2BS Package

Pinout
1) Gnd
2) +Out
3) Vs
4) -Out

2.12
0.084

Port B

2.73
0.107

1.68
0.066

10.80
0.425

15.75
0.620
[9.65]
0.380 (nom)

9.80
0.386

1.14
0.045

10.80
0.425

Port A

0.25
0.010

2.11
0.083

12.70
0.500

2.24
0.088

9.15
0.360

0.64
0.025

0.51
0.020

2.54
0.100

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

MLV Series Low Voltage Pressure Sensors


1-2

EGNS Package

Pinout
1) Gnd
2) +Out
3) Vs
4) -Out

3.90
0.154

10.79
0.425

0.64
0.025

2.10
0.082

all sensors

2.54
0.100

0.51
0.020

e www.allsensors.com

0.25
0.010

2.04
0.080

10.79
0.425

Port B

2.73
0.107

8.13
0.320

9.80
0.386

0.81
0.032

12.70
0.500

15.75
0.620

Absolute devices
are without port hole.

2.12
0.084

[9.65]
0.380 (nom)

4.41
0.174

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

EGBS Package

Pinout

1.14
0.045

10.80
0.425

Port B

10.80
0.425
2.73
0.107
0.51
0.020

1.68
0.066

15.75
0.620
[9.65]
0.380 (nom)

8.13
0.320

9.80
0.386

0.81
0.032

0.25
0.010

p 408 225 4314

0.64
0.025

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Absolute devices are


without port hole

2.11
0.083

12.70
0.500

2.24
0.088

4.41
0.174

f 408 225 2079

1) Gnd
2) +Out
3) Vs
4) -Out

2.54
0.100

Pin 1 2 3 4

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

All Sensors

DS-0274 Rev B
1-2

E1ND Package

Pinout

0.46
0.018

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

5.72
0.225

Pin 8 7 6 5

7.17
0.282
0.64
0.025

12.70
0.500

4.88
0.192

10.79
0.425

2.10
0.082

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

2.04
0.080

10.79
0.425

15.75
0.620

6.45
0.254

Port A

2.73
0.107

0.25
0.010

1.48
0.058

9.80
0.386

16
0.630

Port B

2.54
0.100

8.89
0.350
(min)

Pin 1 2 3 4

E1BD Package

Pinout

0.46
0.018

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

5.72
0.225

Pin 8 7 6 5

9.15
0.360
0.64
0.025

12.70
0.500

4.88
0.192

2.11
0.083
1.14
0.045

10.80
0.425

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

8.89
0.350
(min)

1.68
0.066

2.24
0.088

10.80
0.425

15.75
0.620

16
0.630
6.45
0.254

Port A

2.73
0.107

0.25
0.010

1.48
0.058

9.80
0.386

Port B

2.54
0.100

Pin 1 2 3 4

MLV Series Low Voltage Pressure Sensors


1-2

E2ND Package

Pinout

0.46
0.018

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

5.72
0.225

7.17
0.282

Pin 8 7 6 5

0.64
0.025

12.70
0.500

2.12
0.084

10.79
0.425

Port A

2.10
0.082

e www.allsensors.com

2.54
0.100

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

Pin 1 2 3 4

E2BD Package

Pinout

Pin 8 7 6 5

9.15
0.360

12.70
0.500

0.64
0.025

f 408 225 2079


a 16035 Vineyard Blvd. Morgan Hill, CA 95037

1.68
0.066

10.80
0.425

Port B

2.73
0.107

15.75
0.620

16
0.630
0.25
0.010

9.80
0.386
1.48
0.058

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

8.89
0.350
(min)

1.14
0.045

10.80
0.425

Port A

2.11
0.083

2.24
0.088

2.12
0.084

p 408 225 4314

0.46
0.018

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

5.72
0.225

All Sensors

all sensors

2.04
0.080

10.79
0.425
2.73
0.107

8.89
0.350
(min)

1.48
0.058

15.75
0.620

0.25
0.010

9.80
0.386

16
0.630

Port B

2.54
0.100

Pin 1 2 3 4

DS-0274 Rev B
1-2

EGND Package

Pinout

0.46
0.018

5.72
0.225

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

Pin 8 7 6 5

3.90
0.154
2.12
0.084
4.41
0.174

Absolute devices
are without port hole.

12.70
0.500

0.64
0.025

10.79
0.425

2.10
0.082

Port B

2.04
0.080

10.79
0.425

15.75
0.620

2.73
0.107

8.89
0.350
(min)

0.25
0.010

1.48
0.058

8.13
0.320

9.80
0.386

16
0.630

0.81
0.032

2.54
0.100

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

Pin 1 2 3 4

EGBD Package

Pinout

0.46
0.018

5.08
0.200

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

Pin 8 7 6 5
2.12
0.084

Absolute devices
are without port hole.

12.70
0.500

0.64
0.025

2.11
0.083

10.80
0.425

Port B

1.68
0.066

10.80
0.425

15.75
0.620

16
0.630

9.80
0.386

8.13
0.320

0.81
0.032

2.24
0.088

4.41
0.174

4.28
0.169

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

2.73
0.107

0.25
0.010

1.14
0.045
8.89
0.350
(min)

2.54
0.100

Pin 1 2 3 4

MLV Series Low Voltage Pressure Sensors


1-2

E1NJ Package

Pinout

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

Pin 8 7 6 5

7.17
0.282

2.10
0.082

10.79
0.425

all sensors

0.64
0.025

12.70
0.500

4.88
0.192

1.27
0.050

e www.allsensors.com

15.75
0.620

2.04
0.080

Port A

2.73
0.107

DETAIL A
SCALE 4 : 1

6.45
0.254

9.80
0.386

1.51
0.059

3.94
0.155

0.81
R0.032

10.79
0.425

Port B
0.25
0.010

2.54
0.100

Pin 1 2 3 4

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-10

E2NJ Package

Pinout

p 408 225 4314

2.12
0.084

f 408 225 2079

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect
Pin 8 7 6 5

7.17
0.282

2.10
0.082

12.70
0.500
10.79
0.425

Port A

0.64
0.025

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

2.04
0.080

10.79
0.425

16
0.630

2.73
0.107

DETAIL A
SCALE 4 : 1

9.80
0.386

1.51
0.059

3.94
0.155

0.81
R0.032

15.75
0.620

Port B
0.25
0.010

1.27
0.050

2.54
0.100

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-10

All Sensors

DS-0274 Rev B
1-2

EGNJ Package

Pinout

0.25
0.010

0.81
R0.032

1.51
0.059

3.94
0.155

DETAIL A
SCALE 4 : 1

Pin 8 7 6 5

3.90
0.154

10.79
0.425

0.64
0.025

Absolute devices
are without port hole.

2.10
0.082

12.70
0.500

2.12
0.084
4.41
0.174

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

Port B

2.04
0.080

2.73
0.107

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-10

10.79
0.425

16
0.630

9.80
0.386

8.13
0.320

15.75
0.620

0.81
0.032

1.27
0.050

2.54
0.100

Pin 1 2 3 4

EGBJ Package

Pinout
0.25
0.010

0.81
R0.032

1.51
0.059

3.94
0.155

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

DETAIL A
SCALE 4 : 1
4.28
0.169

12.70
0.500

0.64
0.025

Absolute devices
are without port hole.

2.11
0.083
1.14
0.045

10.80
0.425

Port B

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-10

2.24
0.088

10.80
0.425
2.73
0.107

15.75
0.620

16
0.630

9.80
0.386

8.13
0.320

0.81
0.032

1.68
0.066

4.41
0.174

Pin 8 7 6 5
2.12
0.084

1.27
0.050

2.54
0.100

Pin 1 2 3 4

MLV Series Low Voltage Pressure Sensors


1-2

EGNL Package

Pinout

0.46
0.018

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

2.67
0.105

Pin 8 7 6 5

3.90
0.154
2.12
0.084
4.41
0.174

12.70
0.500

0.64
0.025

Absolute devices
are without port hole.

10.79
0.425

2.10
0.082

2.04
0.080

10.79
0.425

e www.allsensors.com

2.73
0.107

15.75
0.620

16
0.630
0.25
0.010

9.80
0.386

8.13
0.320

1.48
0.058

8.89
0.350
(min)

all sensors

Port B

0.81
0.032

2.54
0.100

Pin 1 2 3 4

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

EGBL Package

Pinout

2.03
0.080

f 408 225 2079


p 408 225 4314

0.46
0.018

1) Gnd
2) +Out
3) Vs
4) -Out
5) Do Not Connect
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

Pin 8 7 6 5

Absolute devices
are without port hole.

12.70
0.500

0.64
0.025

2.11
0.083

10.80
0.425

Port B

1.68
0.066

10.80
0.425

15.75
0.620

9.80
0.386

16
0.630

0.81
0.032

8.13
0.320

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

2.12
0.084

2.24
0.088

4.41
0.174

4.28
0.169

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

All Sensors

2.73
0.107

0.25
0.010

1.14
0.045
8.89
0.350
(min)

2.54
0.100

Pin 1 2 3 4

DS-0274 Rev B
1-2

Suggested Pad Layout

2.54
0.100
(typ.)

1.27
0.050

2.54
0.100
(typ.)

2.29
0.090

2.54
0.100
(typ.)

0.035~0.039 inch
(Finish Size)

0.035~0.039 inch
(Finished Size)

14.99
0.590

16
0.630

PAD-10

PAD-03

PAD-01

Package Characteristics

Package ID

Approximate Port Volume


Port A Port B Units

Notes

Weight

Units

Notes

A6AAx

132

33.6

mm3

9.3 Grams 2

A6BAx

119

20.3

mm3

8.7 Grams 2

A6CAx

119

20.5

mm3

8.8 Grams 2

A6DAx

120

21.3

mm3

8.8 Grams 2

A6EAx

119

33.6

mm3

8.9 Grams 2

A6FAx

125

33.6

mm3

9.2 Grams 2

E1Nx

174

168

mm3

1.2 Grams -

E2Nx

174

168

mm3

1.2 Grams -

EGNx

1.4

168

mm3

0.9 Grams -

Package Notes
Note 1: Add 4.5 mm3 per port with barb fitting.
Note 2: Add 0.15 gram per barb fitting.

Product Labeling

All Sensors
MLV-L02D
A6AAF-N
R9J21-3

Company
Part Number
Lot Number

Example Device Label


* 5 PSI to 150 PSI devices may not be assembled with CoBeam2 TM Technology.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.

MLV Series Low Voltage Pressure Sensors


1-2

XHM SERIES PRESSURE SENSOR


Features
5 inH2O to 30 PSI, absolute, gage or differential pressure.
Calibrated and Temperature compensated.
High Impedance for Low Power.
Small DIP packages.
RoHS compliant.

Media
Air and other non-corrosive gasses.

Applications

all sensors

Medical Devices.
Instrumentation.
HVAC / Environmental Controls.

General Description

e www.allsensors.com

The XHM Series Pressure Sensors provide a precision calibrated and temperature compensated millivolt output signal. A DIP package
allows for through-hole PCB mounting. The XHM Series is available from 5 inH2O to 30 PSI pressure ranges and is intended for use with
dry air and non-corrosive gases.

Operating Pressure

Proof Pressure11

Burst Pressure12

XHMH005

0-5 inH2O

40 inH2O

60 inH2O

XHMH010

0-10 inH2O

40 inH2O

60 inH2O

XHMP001

0-1 PSI

3.6 PSI

7.2 PSI

XHMP005

0-5 PSI

14.5 PSI

20 PSI

XHMP015

0-15 PSI

43.5 PSI

72.5 PSI

XHMP030

0-30 PSI

58 PSI

p 408 225 4314

Device

f 408 225 2079

Pressure Sensor Characteristics

87 PSI

Pressure Sensor Maximum Ratings


Supply Voltage (VS)
Lead Specifications
Average preheating temperature gradient
Soak time
Time above 217C
Time above 230C
Time above 250C
Peak Temperature
Cooling Temperature gradient

All Sensors

+20 Vdc

2.5 C/s
Approx. 3 min
50 s
40 s
15 s
260C
-3.5 C/s

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Specifications
Environmental Specifications
Temperature Ranges
Compensated
Operating
Storage
Humidity Limits

0C to 50C
-40C to 85 C
-40C to 125 C
100% RH
(non condensing)

DS-0333 Rev A

Page 1

1-3

Performance Characteristics1 for: XHM Prime Grade Devices

Characteristics

Min

Typ

Max

Units

Full Scale Span

Notes
2


XHMH005

19.7 20 20.3
mV


XHMH010

24.7 25 25.3
mV

XHMP001

17.82

18

18.8

mV

XHMP005

59.40

60

60.60

mV

XHMP015

89.10

90

90.90

mV

XHMP030

59.40

60

60.60

mV

- 0.25

+0.25

mV

0.1

0.25

%FSO

0.2

0.5

Span Temperature Shift (0 - 50C)

0.4

1.0

%FSO

Repeatability

0.2

0.5

%FSO

Input Impedance

>12

Zero Pressure Offset


Combined Linearity and Hysteresis

Offset Temperature Shift (0 - 50C)

Output Impedance
Common Mode Voltage
Response Time

Long Term Stability of Offset and Span

mV 4

4.8

7.2

100

sec

0.1

mV

10

Max

Units

VDC 8

Performance Characteristics1 for: XHM High Grade Devices

Characteristics

Min

Typ

Full Scale Span

Notes
2


XHMH005

19.5 20 20.5
mV


XHMH010

24.5 25 25.5
mV

XHMP001

17.37

18

18.63

mV

XHMP005

57.90

60

62.10

mV

XHMP015

86.85

90

93.15

mV

XHMP030

57.90

60

62.10

mV

- 0.75

+0.75

mV

-0.5

+0.5

mV

0.2

1.0

%FSO

0.2

1.0

Span Temperature Shift (0 - 50C)

0.4

2.0

%FSO

Repeatability

0.2

0.5

%FSO

Input Impedance

>12

Output Impedance

4.8

7.2

100

sec

0.1

mV

10

Zero Pressure Offset (0 to 10 inH2O)

Zero Pressure Offset (All Other Devices)


Combined Linearity and Hysteresis

Offset Temperature Shift (0 - 50C)

Common Mode Voltage


Response Time

Long Term Stability of Offset and Span

mV 4

VDC 8

XHM Series Pressure Sensor

Page 2

1-3

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

p 408 225 4314

f 408 225 2079

e www.allsensors.com

1. Reference conditions: supply voltage, VS=12 VDC; TA=25 C; RH=50 %; common mode line pressure = 0 bar; pressure applied
to high pressure port.
2. Span is the algebraic difference between the output voltage at full scale pressure and the output at zero pressure. Span is
ratiometric to the supply voltage.
3. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing
pressure.
4. Shift is relative to 25C.
5. Maximum difference in offset respectively maximum difference in span within the temperature range of 0...+50C after:
a) 100 temperature cycles, 0...+50C.
b) 1.0 million pressure cycles, 0 psi to full scale span.
6. Input impedance is the impedance between VS and ground.
7. Output impedance is the impedance between +Vout and -Vout.
8. This is the common mode voltage of the output arms for VS = 12 VDC.
9. Response time for a zero to full scale span pressure step change, 10 to 90 % rise time.
10. Long term stability over a one year period.
11. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters
of the sensing element.
12. Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to
the housing.

all sensors

Specification Notes

All Sensors

DS-0333 Rev A

Page 3

1-3

Package Drawings and Electrical Connections


+0,20

11,90 - 0,10

0,75 0,30

15

3,41

4,10 0,50

3,40 0,50

+0,20
- 0,10

2,30 0,30

Label

7 0,50

15,70 0,50

2,80
2,68
2,30

6,30 0,50

9,28 0,50

2,54

Pin
1
2
3
4
5
6

0,25

FB03 Package

* Internal connection.
Do not connect
for any reason

5,08

5,20 0,50
9,10 0,50

Pin
marking

0,46
19,50 0,50

3,90 0,50

1,90 0,50

11 0,50

0,70

18,75
11,15

9,64 0,50
5,80 0,30
3,35 0,50
R0
,40

Connection
+Vout
GND
-Vout
I / C*
+Vs
I / C*

Note:
The polarity indicated
is for pressure applied
to high pressure port
(forward gage).

low pressure port

high pressure port

All Sensors
TITLE:

SIZE

NOTES
1)Dimensions are in mm

FB-Series Package
FILE NAME

FB03 Package Rev A

FB04 Package
6,90 0,50
8

+0,20

+0,20

15 - 0,10

Pin
1
2
3
4
5
6

,
R0

15,70 0,50

2,69
3,03

11,90 - 0,10

80
high pressure
port

3,16

3,41
2,54

9,28 0,50

5,08

View X

0,

40

Note:
The polarity indicated
is for pressure applied
to high pressure port
(forward gage).

1
3 2

Label

All Sensors

0,75 0,30

TITLE:

SIZE

NOTES
1)Dimensions are in mm

* Internal connection.
Do not connect
for any reason

pin marking

2,30 0,30

16,90 0,50

0,70

8,90

0,50

5,80

3,10 0,50
3,80 0,50
2 0,50

0,46

0,30

6
4 5

Connection
+Vout
GND
-Vout
I / C*
+Vs
I / C*

FB-Series Package
FILE NAME

FB04 Package Rev A

XHM Series Pressure Sensor

Page 4

1-3

How To Order

XHM

Pressure Range

Pressure Mode

Housing

H005

5 inH2O

A1

Absolute

E2

H010

10 inH2O

Differential

Y3

P001

1 PSI

Gage

P005

5 PSI

P015

15 PSI

P030

30 PSI

H005

FB03
DIP 2 ports
same side
FB04
DIP 1 port
axial

Porting
8

Straight

Grade
H

High

Prime

all sensors

Example:

XHM

e www.allsensors.com

Notes:
1: Only available for 15 PSI.
2: Standard for differential devices, "D."
3: Standard for absolute and gage devices, "A and G".

Equivalent Circuit

p 408 225 4314

-Vout

f 408 225 2079

+Vs

+Vout

GND

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

All Sensors

DS-0333 Rev A

Page 5

1-3

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Series
Options

CPM 502
Piezoresistive ceramic pressure
sensor with flush membrane

Excellent chemical resistance

Easy mounting

Pressure ranges
7,5 to 750 psi gauge, absolute
1500 to 9000 psi sealed gauge

Standard Pressure Ranges


Proof pressure
PSI1)

Admissible negative
pressure
[PSI1) / bar]
- 0.15
-2
- 0.20
-3
- 0.40
-6
- 0.80
-11.5

bar
1)

7.5 2)
15
30
75
150
300
750
1500 3)
3000 3)
6000 3)
9000 3)

0.5 2)
1
2
5
10
20
50
100 3)
200 3)
400 3)
600 3)

[PSI / bar]
15
1
30
2
60
4
150
10
225
15
525
35
1500
100
2250
150
5250
350
7500
500
11250
750

vacuum resistant

Burst pressure

Output signal

Sensor thickness

[mV/V]
1.4 to 2.4
2.0 to 3.6
2.0 to 3.5
2.3 to 4.0
3.4 to 6.0
2.4 to 4.0
4.0 to 6.0
3.0 to 4.8
2.5 to 3.9
3.1 to 4.8
3.1 to 4.8

[mm]
6.15
6.17
6.23
6.30
6.35
6.55
6.70
6.70
7.05
7.32
7.55

1)

[PSI / bar]
30
2
45
3
90
6
180
12
300
20
750
50
1800
120
3000
200
7500
500
9750
650
14250
950

Reference Conditions
Supply voltage

2 to 30 VDC stabilized (Imax. = 4 mA)

Bridge resistance

11 k 30 %

Reference temperature

25 C

Measuring supply voltage

10 VDC

Performance Characteristics
Offset
Total error
(Nonlinearity, hysteresis, nonrepeatability)

- 0.1 0.1 mV/V (Other nominal values available on request)


Pressure ranges: 0,4 % FS (terminal based)

Long term stability

0,3 % FS / year (at reference conditions)

TC Offset (TC0)

0,02 % FS/C

TC Span (TCS)

- 0,013 % FS/C

4)
4)

Environmental Specification
Operating temperature range

- 40 to 135 C

Storage temperature range

- 50 to 150 C

Compensated temperature range

0 to 85 C

1)

PSI values around rounded and for reference only


only gauge available
only sealed gauge available
4)
over compensated temperature range
2)
3)

DS-0347 Rev A
Page 1 of 2

Tel:
Fax:

408.225.4314
408.225.2079

www.allsensors.com
info@allsensors.com

CPM-502
Ceramic Pressure Sensor

Specifications

Electrical connections
Standard

Solder pads tinned (Pitch 2.54 mm)

Miscellaneous
Media wetted parts

Ceramic Al2O3 96 %

Weight

approx. 7 g

Dimension

= 18 0.1 mm

d = 6.15 to 7.55 0.1 mm

Mechanical

Venting hole:
- open for gauge version
- closed for absolute and sealed gauge version

+ IN
+ OUT
- IN 1
- OUT
- IN 2
This data sheet contains product specification, properties are not guaranteed. Subject to be changed without notice.

1:
2:
3:
4:
5:

Ordering code

CPM - 502 -

Type of pressure
absolute
gauge
sealed gauge

A
G
S

Pressure range
7.5 psi / (only gauge) 0.5 bar
15 psi / 1 bar
30 psi / 2 bar
75 psi / 5 bar
150 psi / 10 bar
300 psi / 20 bar
750 psi / 50 bar
1500 psi / (only sealed gauge) 100 bar
3000 psi / (only sealed gauge) 200 bar
6000 psi / (only sealed gauge) 400 bar
9000 psi / (only sealed gauge) 600 bar
Electrical connection
Pitch 2,54 mm solder pads tinned
Others on request
Options
Standard

DS-0347 Rev A
Page 2 of 2

L
0
0
0
1
3
7
1
3
6
9

7
1
3
7
5
0
5
K
K
K
K

5
5
0
5
0
0
0
5
0
0
0
2 0 1
9 9 9
0 0 1

Tel:
Fax:

408.225.4314
408.225.2079

www.allsensors.com
info@allsensors.com

CPM 602
Piezoresistive Monolithic
Ceramic Pressure Sensor

Excellent chemical resistance

Easy mounting

Pressure ranges
30 to 6000 psi gauge

Standard Pressure Ranges


Proof pressure
PSI

1)

Admissible
negative pressure
[PSI1) / bar]

bar
[PSI1) / bar]

30
75
150
300
750
1500
3000
6000
other on request

2
5
10
20
50
100
200
400

60
150
300
600
1500
2250
4500
7500

4
10
20
40
100
150
300
500

vacuum
resistant

Burst pressure

Output signal

[PSI1) / bar]

[mV/V]
1.8 to 3.4
2.0 to 3.5
2.4 to 4.0
2.8 to 4.2
2.7 to 4.0
2.0 to 3.2
1.8 to 3.3
1.5 to 3.0

120
300
525
900
2100
4500
6000
9750

8
20
35
60
140
300
400
650

Reference Conditions
Supply voltage

2 to 30 VDC stabilized (Imax. = 4mA)

Bridge resistance

11 k 30 %

Reference temperature
Measuring supply voltage

25 C
10 VDC

Performance Characteristics
Offset
Total error

- 0.1 0.1 mV/V (Other nominal values available on request)

(non-linearity, hysteresis,
non-repeatability)

Pressure ranges: 750 psi: 0.4 % FS (terminal based)


Pressure ranges: > 750 psi: 0.8 % FS typ. (1.5 % FS max.) (terminal based)

Long term stability

0.3 % FS/ year (at reference conditions)

TC Offset (TC0)

0.02 % FS / C

TC Span (TCS)

- 0.012 % FS / C

2)
2)

Environmental Specification
Temperature range

- 40 to 135 C

Storage temperature range


Compensated temperature
range

- 50 to 150 C

1)
2)

0 to 85 C

PSI values around rounded and for reference only


over compensated temperature range

DS-0348 Rev A
Page 1 of 2

Tel:
Fax:

408.225.4314
408.225.2079

www.allsensors.com
info@allsensors.com

CPM-602
Ceramic Pressure Sensor

Specifications

Electrical connection
Standard

Solder pads tinned (pitch 2.54 mm)

Miscellaneous
Media wetted parts

Ceramic Al2O3 96 %

Weight

approx. 5 g

Dimension

= 18 0.1 mm

d = 6.35 0.1 mm

Mechanical

1
2
3
4

2 3 4
This data sheet contains product specifications, properties are not guaranteed. Subject to be change without notice.

+ IN
- OUT
GND
+ OUT

Ordering code

CPM - 602 -

Type of pressure
gauge

Pressure ranges
30 psi / 2 bar
75 psi / 5 bar
150 psi / 10 bar
300 psi / 20 bar
750 psi / 50 bar
1500 psi / 100 bar
3000 psi / 200 bar
6000 psi / 400 bar

0
0
1
3
7
1
3
6

Electrical connection
Pitch 2.54 mm solder pads tinned
Others on request
Options
Standard

DS-0348 Rev A
Page 2 of 2

3
7
5
0
5
K
K
K

0
5
0
0
0
5
0
0
2 0 1
9 9 9
0 0 1

Tel:
Fax:

408.225.4314
408.225.2079

www.allsensors.com
info@allsensors.com

Millivolt Output Prime Pressure Sensors


Low Pressure (2 H2O to 30 H2O) Sensors

Features
0 to 2 H2O to 0 to 30 H2O Pressure Ranges

all sensors

Temperature Compensated
Calibrated Zero and Span
Linearity error 0.1%

Applications
Medical Instrumentation
Environmental Controls

e www.allsensors.com

General Description
The Millivolt Output pressure sensors is based upon a proprietary technology to reduce all output offset or
common mode errors. This model provides a calibrated millivolt output with superior output offset characteristics.
Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position
sensitivity are all significantly reduced when compared to conventional compensation methods. In addition the
sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output

f 408 225 2079

to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to
+16 V is acceptable.

Physical Dimensions

0.25
(6.4)

0.10
Typical
(2.54)

Pin Size
0.010 x 0.020
(0.25 x 0.50)

Pin 1 2 3 4 5 6

0.174 to 0.190
(4.4 to 4.8)

pin 1: N/C
0.21
(5.3)

pin 2: +V supply
pin 3: +Voutput

A
1.08
(27.4)
0.66
(16.0)

0.42
(10.5)

pin 4: -Vsupply
pin 5: -Voutput
pin 6: N/C

0.48
(12.2)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

0.80
(20.3)
0.85
(21.6)
1.10
(27.9)

All Sensors

DS-0090 Rev A
1-6

Pressure Sensor Ratings

Environmental Specifications
Temperature Ranges

16 Vdc

Supply Voltage VS, max

Compensated

-10 to +10 psig

Common-mode pressure

Operating

250C

Lead Temperature, max


(soldering 2-4 sec.)

0 to 50(70) C
-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

2 INCH-D-PRIME-MV

0 - 2 H2O

10mv

100 H2O

200 H2O

5 INCH-D-PRIME-MV

0 - 5 H2O

20 mV

200 H2O

300 H2O

10 INCH-D-PRIME-MV

0 - 10 H2O

20 mV

200 H2O

300 H2O

20 INCH-D-PRIME-MV

0 - 20 H2O

20 mV

200 H2O

500 H2O

30 INCH-D-PRIME-MV

0 - 30 H2O

20 mV

200 H2O

800 H2O

Performance Characteristics for 2 INCH-D-PRIME-MV


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5

Nominal

Maximum

2.0
9.0

10.0

Units
H2O

11.0

mV

Offset Voltage @ zero differential pressure

100

uV

Offset Temperature Shift (0C-50C), note 2

50

uV

Offset Warm-up Shift, note 3

100

uV

Offset Position Sensitivity (1g)

50

uV

100

uV

0.10

%fs

Pressure Hysteresis error, note 4

0.10

%fs

Full Scale Shift (0C-50C), note 2

100

uV

Offset Long Term Drift (one year)


Linearity error, note 4

0.05

Millivolt Low PRIME pressure sensors


1-6

Performance Characteristics for 5 INCH-D-PRIME-MV

Operating Range, differential pressure


Output Span, note 5

Nominal

Maximum

5.0

H2O
21.0

mV

Offset Voltage @ zero differential pressure

100

uV

Offset Temperature Shift (0C-50C), note 2

50

uV

Offset Warm-up Shift, note 3

20

uV

Offset Position Sensitivity (1g)

10

uV

Offset Long Term Drift (one year)

50

uV

0.10

%fs

Pressure Hysteresis error, note 4

0.10

%fs

Full Scale Shift (0C-50C), note 2

100

uV

Maximum

Units

19.0

Linearity error, note 4

20.0

Units

0.05

all sensors

Minimum

e www.allsensors.com

Parameter, note 1

Performance Characteristics for 10 INCH-D-PRIME-MV

10.0

Operating Range, differential pressure


Output Span, note 5

Nominal

21.0

mV

Offset Voltage @ zero differential pressure

100

uV

Offset Temperature Shift (0C-70C), note 2

50

uV

Offset Warm-up Shift, note 3

50

uV

Offset Position Sensitivity (1g)

uV

100

uV

0.10

%fs

Pressure Hysteresis error, note 4

0.10

%fs

Full Scale Shift (0C-50C), note 2

200

uV

Maximum

Units

19.0

20.0

H2O

Offset Long Term Drift (one year)


Linearity error, note 4

0.05

f 408 225 2079

Minimum

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Parameter, note 1

Performance Characteristics for 20 INCH-D-PRIME-MV


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5

Nominal
5.0

21.0

mV

Offset Voltage @ zero differential pressure

100

uV

Offset Temperature Shift (0C-70C), note 2

50

uV

Offset Warm-up Shift, note 3

50

uV

Offset Position Sensitivity (1g)

uV

100

uV

0.10

%fs

Pressure Hysteresis error, note 4

0.10

%fs

Full Scale Shift (0C-50C), note 2

200

uV

19.0

20.0

H2O

Offset Long Term Drift (one year)


Linearity error, note 4

All Sensors

0.05

DS-0090 Rev A
1-6

Performance Characteristics for 30 INCH-D-PRIME-MV


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5

Nominal

Maximum

30.0

Units
H2O

21.0

mV

Offset Voltage @ zero differential pressure

100

uV

Offset Temperature Shift (0C-70C), note 2

50

uV

Offset Warm-up Shift, note 3

50

uV

Offset Position Sensitivity (1g)

uV

100

uV

0.10

%fs

Pressure Hysteresis error, note 4

0.10

%fs

Full Scale Shift (0C-50C), note 2

100

uV

19.0

20.0

Offset Long Term Drift (one year)


Linearity error, note 4

0.05

Specification Notes
1: ALL PARAMETERS ARE MEASURED AT 12.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE.
NOTE

OTHERWISE SPECIFIED.

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 100 useconds.

Optional 90 degree lead bend

Input Resittance

4.5 k ohm

Output Resistance

1.5 k ohm

Equivalent Circuit

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Millivolt Low PRIME pressure sensors


1-6

Millivolt Output Pressure Sensors


C-Grade
Pressure Sensors

Features

all sensors

0 to 0.3 PSI to 0 to 100 PSI Pressure Ranges


1 % linearity version
Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
HVAC

e www.allsensors.com

General Description
The Millivolt Output pressure sensors is based upon a proprietary packaging technology to reduce output offset or
common mode errors. This model provides a calibrated millivolt output with good output offset characteristics. In
addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very
linear output to measured pressure.

f 408 225 2079

These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like. The C-GRADE is a lowest cost version of the millivolt output pressure sensors.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

+16 V is acceptable.

Physical Dimensions

0.25
(6.4)

0.10
Typical
(2.54)

Pin Size
0.010 x 0.020
(0.25 x 0.50)
0.174 to 0.190
(4.4 to 4.8)

pin 1: N/C

Pin 1 2 3 4 5 6
0.21
(5.3)

pin 2: +V supply
pin 3: +Voutput

A
1.08
(27.4)
0.66
(16.0)

0.42
(10.5)

pin 4: -Vsupply
pin 5: -Voutput

pin 6: N/C
0.48
(12.2)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

0.80
(20.3)
0.85
(21.6)
1.10
(27.9)

All Sensors

DS-0094 Rev A
1-7

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Voltage ,Vs

16 Vdc

Temperature Ranges

Common-mode pressure

50 psig

Compensated

250C

Lead Temperature
(soldering 2-4 sec.)

0 to 70 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

4 INCH-D-CGRADE-MV

0 - 4 H2O

40 mV

1 PSI

5 PSI

0.3 PSI-D-CGRADE-MV

0 - O.3 PSI

20 mV

5 PSI

5 PSI

1 PSI-D-CGRADE-MV

0 - 1 PSI

18 mV

5 PSI

15 PSI

5 PSI-D-CGRADE-MV

0 - 5 PSI

60 mV

10 PSI

30 PSI

15 PSI-D-CGRADE-MV

0 - 15 PSI

90 mV

60 PSI

120 PSI

30 PSI-D-CGRADE-MV

0 - 30 PSI

90 mV

90 PSI

150 PSI

100 PSI-D-CGRADE-MV

0 - 100 PSI

100mV

200 PSI

250 PSI

150 PSI-D-CGRADE-MV

0 - 150 PSI

90 mV

200 PSI

250 PSI

15 PSI-A-CGRADE-MV

0 - 15 PSIA

60 mV

60 PSIA

120 PSI

Performance Characteristics for 4 INCH-D-CGRADE-MV


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5

Nominal

Maximum

4.0
38

H2O
42

mV

Offset Voltage @ zero differential pressure

1.5

mV

Offset Temperature Shift (0C-50C), note 2

1.5

mV

1.0

%fs

%fs

Maximum

Units

Linearity, hysteresis error, note 4

40.0

Units

0.5

Span Shift (0C-50C), note 2

Performance Characteristics for 0.3 PSI-D-CGRADE-MV


Parameter, note 1

Minimum

0.3

Operating Range, differential pressure


Output Span, note 5

Nominal

18

22

mV

Offset Voltage @ zero differential pressure

mV

Offset Temperature Shift (0C-70C), note 2

mV

%fs

%fs

Linearity, hysteresis error, note 4


Span Shift (0C-70C), note 2

20.0

PSI

0.5

Millivolt C-Grade Pressure Sensors


1-7

Performance Characteristics for 1 PSI-D-CGRADE-MV


Minimum

Nominal

Maximum

PSI

1.0

Operating Range, differential pressure

20

mV

Offset Voltage @ zero differential pressure

mV

Offset Temperature Shift (0C-70C), note 2

mV

1.0

%fs

%fs

Maximum

Units

Output Span, note 5

16

18

Units

0.5

Linearity, hysteresis error, note 4


Span Shift (0C-70C), note 2

all sensors

Parameter, note 1

Parameter, note 1

Minimum

Nominal
5.0

Operating Range, differential pressure


57

60

PSI
63

mV

Offset Voltage @ zero differential pressure

mV

Offset Temperature Shift (0C-70C), note 2

mV

1.0

%fs

%fs

Maximum

Units

Output Span, note 5

0.5

Linearity, hysteresis error, note 4

f 408 225 2079

Span Shift (0C-70C), note 2

e www.allsensors.com

Performance Characteristics for 5 PSI-D-CGRADE-MV

Parameter, note 1

Minimum

Nominal

PSI

15.0

Operating Range, differential pressure


86

94

mV

Offset Voltage @ zero differential pressure

mV

Offset Temperature Shift (0C-70C), note 2

mV

1.0

%fs

%fs

Maximum

Units

Output Span, note 5

90.0

0.5

Linearity, hysteresis error, note 4


Span Shift (0C-70C), note 2

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Performance Characteristics for 15 PSI-D-CGRADE-MV

Performance Characteristics for 30 PSI-D-CGRADE-MV


Parameter, note 1

Minimum

Nominal
30.0

Operating Range, differential pressure


86

94

mV

Offset Voltage @ zero differential pressure

mV

Offset Temperature Shift (0C-70C), note 2

mV

1.0

%fs

%fs

Output Span, note 5

0.5

Linearity, hysteresis error, note 4


Span Shift (0C-70C), note 2

All Sensors

90

PSI

DS-0094 Rev A
1-7

Performance Characteristics for 100 PSI-D-CGRADE-MV


Minimum

Parameter, note 1

Nominal

Maximum

100.0

Operating Range, differential pressure


96

Units
PSI

104

mV

Offset Voltage @ zero differential pressure

mV

Offset Temperature Shift (0C-70C), note 2

mV

1.0

%fs

%fs

Maximum

Units

Output Span, note 5

100

0.5

Linearity, hysteresis error, note 4


Span Shift (0C-70C), note 2

Performance Characteristics for 150 PSI-D-CGRADE-MV


Minimum

Parameter, note 1

Nominal
150.0

Operating Range, differential pressure


86

PSI
95

mV

Offset Voltage @ zero differential pressure

mV

Offset Temperature Shift (0C-70C), note 2

mV

1.0

%fs

%fs

Maximum

Units

Output Span, note 5

90

0.5

Linearity, hysteresis error, note 4


Span Shift (0C-70C), note 2

Performance Characteristics for 15 PSI-A-CGRADE-MV


Minimum

Parameter, note 1

Nominal
15.0

Operating Range, absolute pressure


86

PSIA
94

mV

Offset Voltage @ zero absolute pressure

mV

Offset Temperature Shift (0C-70C), note 2

mV

1.0

%fs

%fs

Output Span, note 5

90.0

0.5

Linearity, hysteresis error, note 4


Span Shift (0C-70C), note 2

Specification Notes
1: ALL PARAMETERS ARE MEASURED AT 12.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE.
NOTE

OTHERWISE SPECIFIED.

Equivalent Circuit
Input Resittance

5.0 k ohm

Output Resistance

3.0 k ohm

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Millivolt C-Grade Pressure Sensors


1-7

Millivolt Output Pressure Sensors


H-Grade
Pressure Sensors

Features

all sensors

0 to 4 H2O to 0 to 100 PSI Pressure Ranges


0.5 % linearity...high accuracy version
Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
HVAC

The Millivolt Output pressure sensors is based upon a proprietary packaging technology to reduce output offset or common mode
errors. This model provides a calibrated millivolt output with excellent output offset characteristics. In addition the sensor utilizes a
silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This
series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The H-GRADE is a high

e www.allsensors.com

General Description

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +16 V is acceptable.

Pin Size
0.010 x 0.020
(0.25 x 0.50)

Pinout (note 1)

0.10 Typical
(2.54)
0.174 to 0.190
(4.4 to 4.8)

pin 3: +Voutput

0.42
(10.5)

A
1.08
(27.4)
0.66
(16.0)

pin 2: +V supply

0.21
(5.3)

+Vs upply

pin 1: N/C

Pin 1 2 3 4 5 6

p 408 225 4314

0.25
(6.4)

Equivalent Circuit

pin 4: -Vsupply

-Vout

pin 5: -Voutput

+Vout

pin 6: N/C
0.48
(12.2)

0.55
(14.0)

0.80
(20.3)

NOTES:
1) Dimensions in inches (millimeters)

0.85
(21.6)
1.10
(27.9)

-Vs upply
Input Resittance

20 k ohm

Output Resistance

3.0 k ohm

Approvals
MKT

As Is

DATE

With Change

MFG

As Is

All Sensors

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0095 Rev C
1-8

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Physical Dimensions

f 408 225 2079

accuracy version of the millivolt output pressure sensors.

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Voltage, Vs

16 Vdc

Temperature Ranges

Common-mode pressure

50 psig

Compensated

Lead Temperature
(soldering 2-4 sec.)

250C

0 to 70 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

4 INCH-D-HGRADE-MV

0 - 4 H2O

40 mV

3 PSI

15 PSI

0.3 PSI-D-HGRADE-MV

0 - 0.3 PSI

20 mV

5 PSI

15 PSI

1 PSI-D-HGRADE-MV

0 - 1 PSI

18 mV

5 PSI

15 PSI

5 PSI-D-HGRADE-MV

0 - 5 PSI

60 mV

10 PSI

30 PSI

15 PSI-D-HGRADE-MV

0 - 15 PSI

90 mV

60 PSI

120 PSI

30 PSI-D-HGRADE-MV

0 - 30 PSI

90 mV

90 PSI

150 PSI

100 PSI-D-HGRADE-MV

0 - 100 PSI

100 mV

200 PSI

250 PSI

150 PSI-D-HGRADE-MV

0 - 150 PSI

90 mV

200 PSI

250 PSI

15 PSI-A-HGRADE-MV

0 - 15 PSIA

90 mV

60 PSIA

120 PSIA

30 PSI-A-HGRADE-MV

0 - 30 PSIA

90 mV

90 PSIA

150 PSIA

100 PSI-A-HGRADE-MV

0 - 100 PSIA

100 mV

200 PSIA

250 PSIA

Performance Characteristics for 4 INCH-D-HGRADE-MV


Minimum

Nominal

Maximum

Units

--

--

H2O

39.5

40.0

40.5

mV

Offset Voltage @ zero differential pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1
Operating Range, differential pressure
Output Span, note 5

Performance Characteristics for 0.3 PSI-D-HGRADE-MV


Minimum

Nominal

Maximum

Units

--

0.3

--

PSI

19.8

20.0

20.2

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1
Operating Range, differential pressure
Output Span, note 5

Millivolt H-Grade Pressure Sensors


1-8

Minimum

Nominal

Maximum

Units

--

1.0

--

PSI

17.82

18.0

18.18

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

5.0

--

PSI

59.4

60.0

60.6

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

15.0

--

PSI

89.1

90.0

90.9

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

30.0

--

PSI

89.1

90.0

90.9

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1
Operating Range, differential pressure
Output Span, note 5

all sensors

Performance Characteristics for 1 PSI-D-HGRADE-MV

Operating Range, differential pressure


Output Span, note 5

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 5 PSI-D-HGRADE-MV

Operating Range, differential pressure


Output Span, note 5

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for 15 PSI-D-HGRADE-MV

Performance Characteristics for 30 PSI-D-HGRADE-MV


Parameter, note 1
Operating Range, differential pressure
Output Span, note 5

All Sensors

DS-0095 Rev C
1-8

Performance Characteristics for 100 PSI-D-HGRADE-MV


Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

100.0

--

PSI

Output Span, note 5

99

100

101

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

150.0

--

PSI

Output Span, note 5

89

90

91

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1

Performance Characteristics for 150 PSI-D-HGRADE-MV


Parameter, note 1

Performance Characteristics for 15 PSI-A-HGRADE-MV


Minimum

Nominal

Maximum

Units

--

15.0

--

PSIA

89.1

90.0

90.9

mV

Offset Voltage @ zero absolute pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

30.0

--

PSIA

89.1

90.0

90.9

mV

Offset Voltage @ zero absolute pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1
Operating Range, absolute pressure
Output Span, note 5

Performance Characteristics for 30 PSI-A-HGRADE-MV


Parameter, note 1
Operating Range, absolute pressure
Output Span, note 5

Millivolt H-Grade Pressure Sensors


1-8

Minimum

Nominal

Maximum

Units

--

100.0

--

PSIA

99.0

100.0

101.0

mV

Offset Voltage @ zero absolute pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

500

uV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1
Operating Range, absolute pressure
Output Span, note 5

all sensors

Performance Characteristics for 100 PSI-A-HGRADE-MV

Specification Notes
1: All parameters are measured at 12.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure
Port B. For ABSOLUTE devices pressure is applied to Port A, and the output polarity is reversed.
note 2: Shift is relative to 25C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The voltage added to the offset voltage at full scale pressure.
note

e www.allsensors.com

measurements are with positive pressure applied to

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

p 408 225 4314

f 408 225 2079

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.

All Sensors

DS-0095 Rev C
1-8

Millivolt Output Pressure Sensors


Prime Grade
Pressure Sensors

Features
0 to 0.3 PSI to 0 to 150 PSI Pressure Ranges
Highest accuracy version
Temperature Compensated
Calibrated Zero and Span

Applications

all sensors

Medical Instrumentation
Environmental Controls
HVAC

General Description
The Millivolt Output pressure sensor is based upon a proprietary packaging technology to reduce output offset or common mode

e www.allsensors.com

errors. This model provides a calibrated millivolt output with excellent output offset characteristics. In addition the sensor utilizes a
silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series
is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The PRIME GRADE is the highest
accuracy version of the millivolt output pressure sensors.

p 408 225 4314

f 408 225 2079

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +16 V is acceptable.

Physical Dimensions
21.59
0.850

pin 1: N/C

20.32
0.800

2.40
0.094

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

pin 2: +V supply
pin 3: +Voutput

4.81
0.189

pin 4: -Vsupply
5.33
0.210

10.67
0.420

Port B

10.67
0.420

27.43
1.080

4.42
0.174

13.97
0.550

3.18
0.125

12.19
0.480

pin 5: -Voutput
pin 6: N/C

3.56
0.140

Port A
[6.35]
0.250 (min)

0.25
0.010
8.74
0.344

Pin 1
Identifier

0.51
0.020

3.81
0.150
1.27
0.050

2.54
0.100

Approvals
MKT DATE

As Is

With Change

MFG DATE

As Is

All Sensors

With Change

ENG DATE

As Is

With Change

QA DATE

As Is

With Change

DS-0096 Rev B
1-9

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Supply Voltage VS

16 Vdc

Temperature Ranges

Common-mode pressure

50 psig

Compensated

270C

Lead Temperature
(soldering 2-4 sec.)

0 to 70 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

0 - 0.3 PSI

20 mV

5 PSI

15 PSI

1 PSI-D-PRIME-MV

0 - 1 PSI

18 mV

5 PSI

15 PSI

5 PSI-D-PRIME-MV

0 - 5 PSI

60 mV

10 PSI

30 PSI

15 PSI-D-PRIME-MV

0 - 15 PSI

90 mV

60 PSI

120 PSI

15 PSI-A-PRIME-MV

0 - 15 PSIA

90 mV

60 PSIA

120 PSIA

30 PSI-D-PRIME-MV

0 - 30 PSI

90 mV

90 PSI

150 PSI

30 PSI-A-PRIME-MV

0 - 30 PSIA

90 mV

90 PSIA

150 PSIA

100 PSI-D-PRIME-MV

0 - 100 PSI

100 mV

200 PSI

250 PSI

100 PSI-A-PRIME-MV

0 - 100 PSIA

100 mV

200 PSIA

250 PSIA

150 PSI-D-PRIME-MV

0 - 150 PSI

90 mV

200 PSI

250 PSI

Part Number
0.3 PSI-D-PRIME-MV

Performance Characteristics for 0.3 PSI-D-PRIME-MV


Minimum

Nominal

Maximum

Units

19.8

20.0

20.2

mV

Offset Voltage @ zero differential pressure

0.3

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.1

0.25

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Minimum

Nominal

Maximum

Units

17.82

18.0

18.18

mV

Offset Voltage @ zero differential pressure

0.3

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.1

0.25

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Parameter, note 1
Output Span, note 4

Performance Characteristics for 1 PSI-D-PRIME-MV


Parameter, note 1
Output Span, note 4

millivolt output prime grade pressure sensors


1-9

Minimum

Nominal

Maximum

Units

59.4

60.0

60.6

mV

Offset Voltage @ zero differential pressure

0.3

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.1

0.25

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Minimum

Nominal

Maximum

Units

89.1

90.0

90.9

mV

Offset Voltage @ zero differential pressure

0.3

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Minimum

Nominal

Maximum

Units

89.1

90.0

90.9

mV

Offset Voltage @ zero absolute pressure

0.5

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Minimum

Nominal

Maximum

Units

89.1

90.0

90.9

mV

Offset Voltage @ zero differential pressure

0.3

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Parameter, note 1
Output Span, note 4

all sensors

Performance Characteristics for 5 PSI-D-PRIME-MV

Output Span, note 4

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 15 PSI-D-PRIME-MV

Output Span, note 4

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for 15 PSI-A-PRIME-MV

Performance Characteristics for 30 PSI-D-PRIME-MV


Parameter, note 1
Output Span, note 4

All Sensors

DS-0096 Rev B
1-9

Performance Characteristics for 30 PSI-A-PRIME-MV


Minimum

Nominal

Maximum

Units

89.1

90.0

90.9

mV

Offset Voltage @ zero absolute pressure

0.5

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Minimum

Nominal

Maximum

Units

99.0

100

101

mV

Offset Voltage @ zero differential pressure

0.3

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Minimum

Nominal

Maximum

Units

99.0

100

101

mV

Offset Voltage @ zero absolute pressure

0.5

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Minimum

Nominal

Maximum

Units

89.1

90.0

90.1

mV

Offset Voltage @ zero differential pressure

0.3

mV

Offset Temperature Shift (0C-70C), note 2

250

uV

Linearity, hysteresis error, note 3

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

1.0

%FSS

Parameter, note 1
Output Span, note 4

Performance Characteristics for 100 PSI-D-PRIME-MV


Parameter, note 1
Output Span, note 4

Performance Characteristics for 100 PSI-A-PRIME-MV


Parameter, note 1
Output Span, note 4

Performance Characteristics for 150 PSI-D-PRIME-MV


Parameter, note 1
Output Span, note 4

millivolt output prime grade pressure sensors


1-9

Specification Notes
1: All parameters are measured at 12.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure measurements are with
Port B.
note 2: Shift is relative to 25C.
note 3: Measured at one-half full scale rated pressure using best straight line curve fit.
note 4: The span is the algerbraic difference between full scale output voltage and the offset voltage.
note

positive pressure applied to

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 100 useconds.

Equivalent Circuit

-Vout

all sensors

+Vsupply

+Vout

Input Resistance

5.0 k ohm

Output Resistance

3.0 k ohm

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

p 408 225 4314

f 408 225 2079

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

e www.allsensors.com

-Vsupply

All Sensors

DS-0096 Rev B
1-9

MiniatureLowPressureSensors
Low Pressure (1 H2O to 30 H2O) Sensors

Features
0 to 1 H2O to 0 to 30 H2O Pressure Ranges
Matched pressure port volumes
Temperature Compensated
Calibrated Zero and Span

all sensors

Applications
Medical Instrumentation
Environmental Controls
HVAC

model provides a calibrated millivolt output with superior output offset characteristics. Output offset errors due to change in temperature,
stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional
compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very
linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series is
intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +16 V is acceptable.

Equivalent Circuit
+Vsupply
3

Input Resittance

4.5 k ohm

Output Resistance

1.5 k ohm

+ Voutput
2

-Voutput
4

-Vsupply
1

All Sensors

f 408 225 2079

The Millivolt Output pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This

e www.allsensors.com

General Description

DS-0108 Rev A
1-10

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Voltage, Vs

16 Vdc

Temperature Ranges

Common-mode pressure

10 psig

Compensated

250C

Lead Temperature
(soldering 2-4 sec.)

0 to 50(70) C

Operating

Standard Pressure Ranges

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Single in Line Packages-SIP


One Port
Part Number

Operating Pressure

Two Ports Same Side

Two Ports Opposite Side

Part Number

Part Number

0 - 1 H2O

1 INCH-D2-MV-MINI

2 INCH-G-MV-MINI

0 - 2 H2O

2 INCH-D1-MV-MINI

2 INCH-D2-MV-MINI

5 INCH-G-MV-MINI

0 - 5 H2O

5 INCH-D1-MV-MINI

5 INCH-D2-MV-MINI

10 INCH-G-MV-MINI

0 - 10 H2O

10 INCH-D1-MV-MINI

10 INCH-D2-MV-MINI

20 INCH-G-MV-MINI

0 - 20 H2O

20 INCH-D1-MV-MINI

20 INCH-D2-MV-MINI

30 INCH-G-MV-MINI

0 - 30 H2O

30 INCH-D1-MV-MINI

30 INCH-D2-MV-MINI

Dual in Line Packages


Two Ports Same Side

Two Ports Opposite Side

Operating Pressure

Part Number

Part Number

2 INCH-GDIP-MV-MINI

0 - 2 H2O

2 INCH-D1DIP-MV-MINI

2 INCH-D2DIP-MV-MINI

5 INCH-GDIP-MV-MINI

0 - 5 H2O

5 INCH-D1DIP-MV-MINI

5 INCH-D2DIP-MV-MINI

10 INCH-GDIP-MV-MINI

0 - 10 H2O

10 INCH-D1DIP-MV-MINI

10 INCH-D2DIP-MV-MINI

20 INCH-GDIP-MV-MINI

0 - 20 H2O

20 INCH-D1DIP-MV-MINI

20 INCH-D2DIP-MV-MINI

30 INCH-GDIP-MV-MINI

0 - 30 H2O

30 INCH-D1DIP-MV-MINI

30 INCH-D2DIP-MV-MINI

One Port
Part Number

Performance Characteristics for 1 INCH-D2-MV-MINI


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, @ 1 H2O, note 5

Nominal

Maximum

1.0
8.0

10

Units
H2O

12.0

mV

Offset Voltage @ zero differential pressure

500

mV

Offset Temperature Shift (0C-50C), note 2

250

uV

Offset Warm-up Shift, note 3

100

uV

Offset Position Sensitivity (1g)

50

uV

200

uV

0.25

%fs

300

uV

Offset Long Term Drift (one year)


Linearity, hysteresis error, note 4
Span Shift (0C-50C), @ 1 H2O, note 2

0.05

MiniatureLowPressureSensors
1-10

Performance Characteristics for 2 INCH-Dx-MV-MINI

9.0

Operating Range, differential pressure


Output Span, @ 4 H2O, note 5

Maximum

2.0

Operating Range, differential pressure


Output Span, @ 2 H2O, note 5

Nominal

10.0

H2O
11.0

4.0
18.0

20.0

Units

mV
mV

22.0

mV

Offset Voltage @ zero differential pressure

500

uV

Offset Temperature Shift (0C-50C), note 2

250

uV

Offset Warm-up Shift, note 3

100

uV

Offset Position Sensitivity (1g)

50

uV

200

uV

0.25

%fs

200

uV

Maximum

Units

Offset Long Term Drift (one year)


Linearity, hysteresis error, note 4

0.05

Span Shift (0C-50C), @ 2 H2O, note 2

all sensors

Minimum

e www.allsensors.com

Parameter, note 1

Performance Characteristics for 5 INCH-Dx-MV-MINI

Operating Range, differential pressure

Nominal
5.0

21.0

mV

Offset Voltage @ zero differential pressure

500

uV

Offset Temperature Shift (0C-50C), note 2

150

uV

Offset Warm-up Shift, note 3

50

uV

Offset Position Sensitivity (1g)

10

uV

100

uV

0.25

%fs

200

uV

Maximum

Units

Output Span, note 5

19.0

20.0

H2O

Offset Long Term Drift (one year)


Linearity, hysteresis error, note 4

0.05

Span Shift (0C-50C), note 2

f 408 225 2079

Minimum

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Parameter, note 1

Performance Characteristics for 10 INCH-Dx-MV-MINI


Parameter, note 1

Minimum

Nominal

H2O

10.0

Operating Range, differential pressure

21.0

mV

Offset Voltage @ zero differential pressure

500

uV

Offset Temperature Shift (0C-70C), note 2

150

uV

Offset Warm-up Shift, note 3

50

uV

Offset Position Sensitivity (1g)

uV

100

uV

0.25

%fs

200

uV

Output Span, note 5

19.0

20.0

Offset Long Term Drift (one year)


Linearity, hysteresis error, note 4

0.05

Span Shift (0C-70C), note 2

All Sensors

DS-0108 Rev A
1-10

Performance Characteristics for 20 INCH-Dx-MV-MINI


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5

Nominal

Maximum

5.0

Units
H2O

21.0

mV

Offset Voltage @ zero differential pressure

500

uV

Offset Temperature Shift (0C-70C), note 2

150

uV

Offset Warm-up Shift, note 3

50

uV

Offset Position Sensitivity (1g)

uV

100

uV

0.25

%fs

200

uV

Maximum

Units

19.0

20.0

Offset Long Term Drift (one year)


Linearity, hysteresis error, note 4

0.05

Span Shift (0C-70C), note 2

Performance Characteristics for 30 INCH-Dx-MV-MINI


Parameter, note 1

Minimum

Operating Range, differential pressure

Nominal
30.0

H2O
21.0

mV

Offset Voltage @ zero differential pressure

500

uV

Offset Temperature Shift (0C-70C), note 2

150

uV

Offset Warm-up Shift, note 3

50

uV

Offset Position Sensitivity (1g)

uV

100

uV

0.25

%fs

200

uV

Output Span, note 5

19.0

20.0

Offset Long Term Drift (one year)


Linearity, hysteresis error, note 4

0.05

Span Shift (0C-70C), note 2

Specification Notes
NOTE 1:

ALL PARAMETERS ARE MEASURED AT 12.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE B-PORT CONFIGURATION.
SHIFT IS RELATIVE TO 25C.
SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE.

OTHERWISE SPECIFIED.

2:
3:
NOTE 4:
NOTE 5:
NOTE
NOTE

MiniatureLowPressureSensors
1-10

Physical Dimensions
Dual in Line (SDXL)**

Two Pressure Port Same Side

all sensors

pin
pin
pin
pin

1: +Vout
2: gnd
3: -Vout
5: Vsupply
0.280
(7.1)

0.50
(12.7)
6 5 4
0.62
(15.7)

Pin 1 2 3
0.080 O.D.
(2.00)

e www.allsensors.com

0.10
Typical
(2.54)

Dual in Line (DIP)

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

f 408 225 2079

Two Pressure Port Two Sides

**SDXL ORDERING INFORMATION

Two Ports Same Side

Two Ports Opposite Side

Operating Pressure

Part Number

Part Number

2 INCH-GDIP-MV-SDXL

0 - 2 H2O

2 INCH-D1DIP-MV-SDXL

2 INCH-D2DIP-MV-SDXL

5 INCH-GDIP-MV-SDXL

0 - 5 H2O

5 INCH-D1DIP-MV-SDXL

5 INCH-D2DIP-MV-SDXL

10 INCH-GDIP-MV-SDXL

0 - 10 H2O

10 INCH-D1DIP-MV-SDXL

10 INCH-D2DIP-MV-SDXL

20 INCH-GDIP-MV-SDXL

0 - 20 H2O

20 INCH-D1DIP-MV-SDXL

20 INCH-D2DIP-MV-SDXL

30 INCH-GDIP-MV-SDXL

0 - 30 H2O

30 INCH-D1DIP-MV-SDXL

30 INCH-D2DIP-MV-SDXL

One Port
Part Number

All Sensors

DS-0108 Rev A
1-10

Millivolt Output Pressure Sensors


Features
Package A

all sensors

Temperature Compensated
Calibrated Zero and Span

Applications
Non Invasive Blood Pressure

e www.allsensors.com

Package M

General Description
This data sheet describes two package configuration of pressure sensors for use in non invasive blood pressure maeasurement.

0.30
(7.6)

0.50
(12.7)

pin 1: +V supply

A-port

pin 2: Ground
0.62
(15.7)

pin 3: +Voutput
pin 4: -N/C

Pin 1 2 3 4
0.10
Typical
(2.54)

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

B-port

0.380

f 408 225 2079

The output voltager is ratiometric to the supply voltage and is offered in either millivolt or amplified output configuration.

0.080 O.D.
(2.00)

pin 1: N/C
pin 2: +V supply
pin 3: +Voutput
pin 4: -Vsupply
pin 5: -Voutput
pin 6: N/C

All Sensors

DS-0048 Rev A
1-11

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

see below

Supply Supply Voltage VS

Temperature Ranges

1500mmHg

Proof Pressure

Compensated

250C

Lead Temperature
(soldering 2-4 sec.)

10 to 50 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH

Standard Package Types


Part Number-Side Port

(non condensing)
Package Type

Nominal Span

Supply Voltage

BP01-D-MV

15 mV

5 volts

BP01-G-4V-MINI

4.2 volts

5 volts

Performance Characteristics for BP01-D-MV


Minimum

Parameter, note 1
Operating Range, gage pressure

Nominal

Maximum

300
14.85

Units
mmHg

15.0

15.15

mV

05

mmHg

Offset Temperature Shift (10C-50C), note 2

0.2

mmHg/C

Linearity, hysteresis error 0 - 200 mmHg, note 3

0.1

%fs

Linearity, hysteresis error 0 - 300 mmHg, note 3

0.2

%fs

Span Shift (10C-50C), note 2

0.5

%fs

Maximum

Units

Output Span, note 4


Offset Voltage @ zero pressure

Performance Characteristics for BP01-G-4V-MINI


Minimum

Parameter, note 1

Nominal

Operating Range, gage pressure

mmHg

300
4.1

4.2

4.3

0.18

0.25

0.32

Offset Temperature Shift (10C-50C), note 2

0.2

mmHg/C

Linearity, hysteresis error 0 - 200 mmHg, note 3

0.1

%fs

Linearity, hysteresis error 0 - 300 mmHg, note 3

0.2

%fs

Span Shift (10C-50C), note 2

0.5

%fs

Output Span, note 4


Offset Voltage @ zero pressure

Specification Notes
NOTE

1: ALL

PARAMETERS ARE MEASURED AT ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED.

PORT B.
25C READINGS

PRESSURE

MEASUREMENTS ARE WITH

POSITIVE PRESSURE APPLIED TO


NOTE
NOTE
NOTE

2: SHIFT IS RELATIVE TO
3: MEASURED AT ONE-HALF FULL SCALE
4: THE VOLTAGE ADDED TO THE OFFSET

TAKEN AT

10C AND 50C.

RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.


VOLTAGE AT FULL SCALE PRESSURE.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Blood Pressure Sensors


1-11

Miniature Pressure Sensors


C-Grade
Pressure Sensors

Features

all sensors

0 to 4 H2O to 0 to 100 PSI Pressure Ranges


1 % linearity version
Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
HVAC

General Description
e www.allsensors.com

The Miniature series pressure sensors are based upon a proprietary technology to reduce the size of the sensor and
yet maintain a high level of performance. This model provides a calibrated millivolt output with superior output
offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time
period, and position sensitivity are all significantly reduced when compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a

f 408 225 2079

very linear output to measured pressure.


These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature
range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the
like. The C-GRADE is a lowest cost version of the millivolt output pressure sensors.

all dimensions in inches

Equivalent Circuit

Single Pressure Port

No Pressure Port
Marking:
right dot: Silver C-Grade
left dot:
L04: white
L10: yellow
0.3: pink
1.0: green
05: blue
15: purple
30: orange
100: brown

Input Resittance
Dual Pressure Port

5.0 k ohm

Output Resistance 3.0 k ohm

Approvals
MKT

As Is

DATE

With Change

MFG

As Is

All Sensors

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0106 Rev B
1-12

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Physical Dimensions

p 408 225 4314

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage.

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Supply Voltage VS

16 Vdc

Temperature Ranges

Common-mode pressure

50 psig

Compensated

Lead Temperature
(soldering 2-4 sec.)

250C

0 to 70 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


No Prssure Port
Part Number

Operating Pressure

Single Pressure Port

Dual Pressure Port

Part Number

Part Number

Proof Pressure

4 INCH-G-CGRADE-MINI

0 - 4 H2O

4 INCH-GF-CGRADE-MINI

4 INCH-D-CGRADE-MINI

3 PSI

0.3 PSI-G-CGRADE-MINI

0 - O.3 PSI

0.3 PSI-GF-CGRADE-MINI

0.3 PSI-D-CGRADE-MINI

3 PSI

10 INCH-GF-CGRADE-MINI

10 INCH-D-CGRADE-MINI

5 PSI

10 INCH-G-CGRADE-MINI

0 - 10 H2O

1 PSI-G-CGRADE-MINI

0 - 1 PSI

1 PSI-GF-CGRADE-MINI

1 PSI-D-CGRADE-MINI

10 PSI

5 PSI-G-CGRADE-MINI

0 - 5 PSI

5 PSI-GF-CGRADE-MINI

5 PSI-D-CGRADE-MINI

20 PSI

15 PSI-A-CGRADE-MINI

0 - 15 PSIA

15 PSI-AF-CGRADE-MINI

15 PSI-G-CGRADE-MINI

0-15 PSI

15 PSI-GF-CGRADE-MINI

30 PSI-A-CGRADE-MINI

0-30 PSIA

30 PSI-AF-CGRADE-MINI

30 PSI-G-CGRADE-MINI

0-30 PSI

30 PSI-GF-CGRADE-MINI

100 PSI-G-CGRADE-MINI

0-100 PSI

100 PSI-GF-CGRADE-MINI

60 PSI
60 PSI

15 PSI-D-CGRADE-MINI

60 PSI
60 PSI

30 PSI-D-CGRADE-MINI

150 PSI

Performance Characteristics for 4 INCH-G-CGRADE-MINI


Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

4.0

--

H2O

Output Span, note 5

23

25

27

mV

Offset Voltage @ zero differential pressure

--

--

1.5

mV

Offset Temperature Shift (0C-50C), note 2

--

--

1.5

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-50C), note 2

--

--

%fs

Parameter, note 1

Performance Characteristics for 10 INCH-G-CGRADE-MINI


Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

10.0

--

H2O

Output Span, note 5

18

20

22

mV

Offset Voltage @ zero differential pressure

--

--

1.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

1.5

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1

Miniature C-grade Pressure Sensors


1-12

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

0.3

--

PSI

Output Span, note 5

18

20.0

22

mV

Offset Voltage @ zero differential pressure

--

--

mV

Offset Temperature Shift (0C-70C), note 2

--

--

mV

Linearity, hysteresis error, note 4

--

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

1.0

--

PSI

Output Span, note 5

16

18

20

mV

Offset Voltage @ zero differential pressure

--

--

mV

Offset Temperature Shift (0C-70C), note 2

--

--

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

5.0

--

PSI

Output Span, note 5

57

60

63

mV

Offset Voltage @ zero differential pressure

--

--

mV

Offset Temperature Shift (0C-70C), note 2

--

--

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

Operating Range, gage pressure

--

15.0

--

PSI

Output Span, note 5

85

90.0

95

mV

Offset Voltage @ zero gage pressure

--

--

mV

Offset Temperature Shift (0C-70C), note 2

--

--

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1

all sensors

Performance Characteristics for 0.3 PSI-G-CGRADE-MINI

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 1 PSI-G-CGRADE-MINI

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for 5 PSI-G-CGRADE-MINI

Performance Characteristics for 15 PSI-G-CGRADE-MINI


Parameter, note 1

All Sensors

DS-0106 Rev B
1-12

Performance Characteristics for 15 PSI-A-CGRADE-MINI


Minimum

Nominal

Maximum

Units

Operating Range, absolute pressure

--

15.0

--

PSIA

Output Span, note 5

85

90.0

95

mV

Offset Voltage @ zero absolute pressure

--

--

mV

Offset Temperature Shift (0C-70C), note 2

--

--

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

Operating Range, gage pressure

--

30.0

--

PSI

Output Span, note 5

85

90.0

95

mV

Offset Voltage @ zero pressure

--

--

mV

Offset Temperature Shift (0C-70C), note 2

--

--

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

Operating Range, absolute pressure

--

30.0

--

PSIA

Output Span, note 5

85

90.0

95

mV

Offset Voltage @ zero absolute pressure

--

--

mV

Offset Temperature Shift (0C-70C), note 2

--

--

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1

Performance Characteristics for 30 PSI-G-CGRADE-MINI


Parameter, note 1

Performance Characteristics for 30 PSI-A-CGRADE-MINI


Parameter, note 1

Performance Characteristics for 100 PSI-G-CGRADE-MINI


Minimum

Nominal

Maximum

Units

Operating Range, gage pressure

--

100.0

--

PSI

Output Span, note 5

95

100.0

105

mV

Offset Voltage @ zero pressure

--

--

mV

Offset Temperature Shift (0C-70C), note 2

--

--

mV

Linearity, hysteresis error, note 4

--

0.5

1.0

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1

Specification Notes
note 1: All parameters are measured at 12.0 volt excitation, for the nominal full scale pressure and room temperature unless
otherwise specified. Pressure measurements are with positive pressure applied to Port B.
note 2: Shift is relative to 25C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The voltage added to the offset voltage at full scale pressure.

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 100 useconds.

Miniature C-grade Pressure Sensors


1-12

Miniature Pressure Sensors


H-Grade
Pressure Sensors

Features

all sensors

0 to 4 H2O to 0 to 100 PSI Pressure Ranges


0.5 % linearity...high accuracy version
Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
HVAC

General Description
The Miniature series pressure sensors are based upon a proprietary technology to reduce the size of the sensor and

e www.allsensors.com

yet maintain a high level of performance. This model provides a calibrated millivolt output with superior output
offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time
period, and position sensitivity are all significantly reduced when compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a
very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature

f 408 225 2079

range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the
like. The H-GRADE is a high accuracy version of the millivolt output pressure sensors.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage.

Single Pressure Port

Marking:
right dot: gold: H-Grade
left dot:
L04: white
L10: yellow
0.3: pink
1.0: green
05: blue
15: purple
30: orange
100: brown

Input Resittance

5.0 k ohm

Output Resistance

3.0 k ohm

Dual Pressure Port

Approvals
MKT

As Is

DATE

With Change

MFG

As Is

All Sensors

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0107 Rev B
1-13

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

No Pressure Port

p 408 225 4314

Equivalent Circuit

Physical Dimensions

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Supply Voltage VS

16 Vdc

Temperature Ranges

Common-mode pressure

50 psig

Compensated

Lead Temperature
(soldering 2-4 sec.)

250C

0 to (50)70 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


No Prssure Port
Part Number

Operating Pressure

Single Pressure Port

Dual Pressure Port

Part Number

Part Number

Proof Pressure

4 INCH-G-HGRADE-MINI

0 - 4 H2O

4 INCH-GF-HGRADE-MINI

4 INCH-D-HGRADE-MINI

3 PSI

0.3 PSI-G-HGRADE-MINI

0 - 0.3 PSI

0.3 PSI-GF-HGRADE-MINI

0.3 PSI-D-HGRADE-MINI

3 PSI

10 INCH-G-HGRADE-MINI

0 - 10 H2O

10 INCH-GF-HGRADE-MINI 10 INCH-D-HGRADE-MINI

5 PSI

1 PSI-G-HGRADE-MINI

0 - 1 PSI

1 PSI-GF-HGRADE-MINI

1 PSI-D-HGRADE-MINI

10 PSI

5 PSI-G-HGRADE-MINI

0 - 5 PSI

5 PSI-GF-HGRADE-MINI

5 PSI-D-HGRADE-MINI

20 PSI

15 PSI-A-HGRADE-MINI

0 - 15 PSIA

15 PSI-AF-HGRADE-MINI

15 PSI-G-HGRADE-MINI

0-15 PSI

15 PSI-GF-HGRADE-MINI

30 PSI-A-HGRADE-MINI

0 -30 PSIA

30 PSI-AF-HGRADE-MINI

30 PSI-G-HGRADE-MINI

0-30 PSI

30 PSI-GF-HGRADE-MINI

100 PSI-G-HGRADE-MINI

0-100 PSI

100 PSI-GF-HGRADE-MINI

60 PSI
60 PSI

15 PSI-D-HGRADE-MINI

60 PSI
60 PSI

30 PSI-D-HGRADE-MINI

150 PSI

Performance Characteristics for 4 INCH-G-HGRADE-MINI


Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

4.0

--

H2O

Output Span, note 5

24

25

26

mV

Offset Voltage @ zero differential pressure

--

--

0.5

mV

Offset Temperature Shift (0C-50C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-50C), note 2

--

--

%fs

Parameter, note 1

Performance Characteristics for 10 INCH-G-HGRADE-MINI


Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

10.0

--

H2O

Output Span, note 5

19

20

21

mV

Offset Voltage @ zero differential pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1

Miniature H-grade Pressure Sensors


1-13

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

0.3

--

PSI

Output Span, note 5

19

20

21

mV

Offset Voltage @ zero differential pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

1.0

--

PSI

17.82

18.00

18.18

mV

Offset Voltage @ zero differential pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

5.0

--

PSI

59.4

60.0

60.6

mV

Offset Voltage @ zero differential pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

15.0

--

PSI

89.1

90.0

90.9

mV

Offset Voltage @ zero gage pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1

all sensors

Performance Characteristics for 0.3 PSI-G-HGRADE-MINI

Operating Range, differential pressure


Output Span, note 5

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 1 PSI-G-HGRADE-MINI

Operating Range, differential pressure


Output Span, note 5

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for 5 PSI-G-HGRADE-MINI

Performance Characteristics for 15 PSI-G-HGRADE-MINI


Parameter, note 1
Operating Range, gage pressure
Output Span, note 5

All Sensors

DS-0107 Rev B
1-13

Performance Characteristics for 15 PSI-A-HGRADE-MINI


Minimum

Nominal

Maximum

Units

--

15.0

--

PSIA

89.1

90.0

90.9

mV

Offset Voltage @ zero differential pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

30.0

--

PSI

89.1

90.0

90.9

mV

Offset Voltage @ zero gage pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Minimum

Nominal

Maximum

Units

--

30.0

--

PSIA

89.1

90.0

90.9

mV

Offset Voltage @ zero differential pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1
Operating Range, absolute pressure
Output Span, note 5

Performance Characteristics for 30 PSI-G-HGRADE-MINI


Parameter, note 1
Operating Range, gage pressure
Output Span, note 5

Performance Characteristics for 30 PSI-A-HGRADE-MINI


Parameter, note 1
Operating Range, absolute pressure
Output Span, note 5

Performance Characteristics for 100 PSI-G-HGRADE-MINI


Minimum

Nominal

Maximum

Units

--

100.0

--

PSI

99.0

100.0

101.0

mV

Offset Voltage @ zero gage pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

0.5

mV

Linearity, hysteresis error, note 4

--

0.25

0.5

%fs

Span Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1
Operating Range, gage pressure
Output Span, note 5

Specification Notes
1: All parameters are measured at 12.0 volt excitation, for the nominal full scale pressure and room temperature unless
Pressure measurements are with positive pressure applied to Port B.
note 2: Shift is relative to 25C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The voltage added to the offset voltage at full scale pressure.
note

otherwise specified.

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Miniature H-grade Pressure Sensors


1-13

Miniature Pressure Sensors


Prime Grade
Pressure Sensors

Features
0 to 0.3 PSI to 0 to 100 PSI Pressure Ranges
Highest accuracy version
Temperature Compensated
Calibrated Zero and Span

Applications

General Description

all sensors

Medical Instrumentation
Environmental Controls
HVAC

The Miniature series pressure sensors are based upon a proprietary technology to reduce the size of the sensor and yet maintain a
high level of performance. This model provides a calibrated millivolt output with superior output characteristics. In addition the
sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pres-

e www.allsensors.com

sure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This
series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The PRIME GRADE is the
highest accuracy version of the millivolt output pressure sensors.

Supply Voltage, Vs

16 Vdc

Temperature Ranges

Common-mode pressure

50 psig

Compensated

270C

Lead Temperature
(soldering 2-4 sec.)

p 408 225 4314

Environmental Specifications

0 to 70 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Approvals
MKT DATE

As Is

With Change

MFG DATE

As Is

All Sensors

ENG DATE

With Change

As Is

With Change

QA DATE

As Is

With Change

DS-0110 Rev E
1-14

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Pressure Sensor Characteristics Maximum Ratings

f 408 225 2079

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage.

Standard Pressure Ranges


No Prssure Port: CFNS

Single Pressure Port: CPNS

Dual Pressure Port: CPPS

Part Number

Part Number

Part Number

0.3 PSI-G-PRIME-MINI

0.3 PSI-GF-PRIME-MINI

0.3 PSI-D-PRIME-MINI

10 INCH-G-PRIME-MINI

10 INCH-GF-PRIME-MINI

10 INCH-D-PRIME-MINI

1 PSI-G-PRIME-MINI

1 PSI-GF-PRIME-MINI

5 PSI-G-PRIME-MINI

5 PSI-GF-PRIME-MINI

15 PSI-A-PRIME-MINI

15 PSI-AF-PRIME-MINI

15 PSI-G-PRIME-MINI

15 PSI-GF-PRIME-MINI

30 PSI-A-PRIME-MINI

30 PSI-AF-PRIME-MINI

30 PSI-G-PRIME-MINI

30 PSI-GF-PRIME-MINI

100 PSI-A-PRIME-MINI
100 PSI-G-PRIME-MINI

Operating Pressure

Proof Pressure

0 to 0.3 PSI

3 PSI

0 to 10 inH2O

5 PSI

1 PSI-D-PRIME-MINI

0 to 1 PSI

10 PSI

5 PSI-D-PRIME-MINI

0 to 5 PSI

20 PSI

0 to 15 PSIA

60 PSIA

0 to 15 PSI

60 PSI

0 to 30 PSIA

60 PSIA

0 to 30 PSI

60 PSI

100 PSI-AF-PRIME-MINI

0 to 100 PSIA

150 PSIA

100 PSI-GF-PRIME-MINI

0 to 100 PSI

150 PSI

15 PSI-D-PRIME-MINI

30 PSI-D-PRIME-MINI

Performance Characteristics for: 0.3 PSI-G-PRIME-MINI , 0.3 PSI-GF-PRIME-MINI , 0.3 PSI-D-PRIME-MINI


Minimum

Nominal

Maximum

Units

19.0

20.0

21.0

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.1

0.25

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Parameter, note 1
Output Span, note 4

Performance Characteristics for: 10 INCH-G-PRIME-MINI , 10 INCH-GF-PRIME-MINI , 10 INCH-D-PRIME-MINI


Minimum

Nominal

Maximum

Units

19.0

20.0

21.0

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.1

0.25

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Parameter, note 1
Output Span, note 4

Performance Characteristics for: 1 PSI-G-PRIME-MINI , 1 PSI-GF-PRIME-MINI , 1 PSI-D-PRIME-MINI


Minimum

Nominal

Maximum

Units

17.82

18.0

18.18

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.1

0.25

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Parameter, note 1
Output Span, note 4

Miniature Prime Grade Pressure Sensors


1-14

Minimum

Nominal

Maximum

Units

59.4

60.0

60.6

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.1

0.25

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Parameter, note 1
Output Span, note 4

all sensors

Performance Characteristics for: 5 PSI-G-PRIME-MINI , 5 PSI-GF-PRIME-MINI , 5 PSI-D-PRIME-MINI

Nominal

Maximum

Units

89.1

90.0

90.9

mV

Offset Voltage @ zero absolute pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.1

0.3

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Output Span, note 4

f 408 225 2079

Minimum

Parameter, note 1

e www.allsensors.com

Performance Characteristics for: 15 PSI-A-PRIME-MINI , 15 PSI-AF-PRIME-MINI

Nominal

Maximum

Units

89.1

90.0

90.9

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Output Span, note 4

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Minimum

Parameter, note 1

p 408 225 4314

Performance Characteristics for: 15 PSI-G-PRIME-MINI , 15 PSI-GF-PRIME-MINI , 15 PSI-D-PRIME-MINI

Performance Characteristics for: 30 PSI-A-PRIME-MINI , 30 PSI-AF-PRIME-MINI


Minimum

Nominal

Maximum

Units

89.1

90.0

90.9

mV

Offset Voltage @ zero absolute pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Parameter, note 1
Output Span, note 4

All Sensors

DS-0110 Rev E
1-14

Performance Characteristics for: 30 PSI-G-PRIME-MINI , 30 PSI-GF-PRIME-MINI , 30 PSI-D-PRIME-MINI


Minimum

Nominal

Maximum

Units

89.1

90.0

90.9

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Parameter, note 1
Output Span, note 4

Performance Characteristics for: 100 PSI-A-PRIME-MINI, 100 PSI-AF-PRIME-MINI


Minimum

Nominal

Maximum

Units

99.0

100.0

101.0

mV

Offset Voltage @ zero absolute pressure

--

--

0.5

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Parameter, note 1
Output Span, note 4

Performance Characteristics for: 100 PSI-G-PRIME-MINI , 100 PSI-GF-PRIME-MINI


Minimum

Nominal

Maximum

Units

99.0

100.0

101.0

mV

Offset Voltage @ zero differential pressure

--

--

0.3

mV

Offset Temperature Shift (0C-70C), note 2

--

--

250

uV

Linearity, hysteresis error, note 3

--

0.15

0.30

%FSS

Span Temperature Shift (0C-70C), note 2

--

--

1.0

%FSS

Parameter, note 1
Output Span, note 4

Specification Notes
1: All parameters are measured at 12.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure measurements are with
Port B.
note 2: Shift is relative to 25C.
note 3: Measured at one-half full scale rated pressure using best straight line curve fit.
note 4: The span is the algerbraic difference between full scale output voltage and the offset voltage.
note

positive pressure applied to

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Equivalent Circuit
+Vsupply

-Vout

+Vout

-Vsupply

Input Resistance

5.0 k ohm

Output Resistance

3.0 k ohm

Miniature Prime Grade Pressure Sensors


1-14

Packages
CFNS Package
10.16
0.400
3.15
0.124

5.08
0.200

Absolute devices
are without port hole.

6.35
0.250

6.35
0.250

7.30
0.287

12.70
0.500

0.41
R0.016

0.79
0.031

10.17
0.400

Port B

1) Gnd
2) +Out
3) Vs
4) -Out

5.08
0.200

0.64
0.025

Part Marking

0.25
0.010

0.51
0.020 (typ)

2.54
0.100 (typ)

NOTES
1) Dimensions are in inches [mm].
2) For suggested pad layout, see drawing: PAD-01

Pin 1 2 3 4

Marking:
right dot: Red: Prime Grade
left dot:
L10: yellow
0.3: pink
1.0: green
05: blue
15: purple
30: orange
100: brown

all sensors

8.93
0.351

10.77
0.424

5.08
0.200

2.54
0.100 (typ)

5.08
0.200

0.64
0.025
0.41
R0.016

Absolute devices
are without port hole.

Marking:
right dot: Red: Prime Grade
left dot:
L10: yellow
0.3: pink
1.0: green
05: blue
15: purple
30: orange
100: brown

6.35
0.250

4.57
0.180
0.79
0.031

Port B

10.17
0.400

1) Gnd
2) +Out
3) Vs
4) -Out

1.27
0.050

4.35
0.171

6.35
0.250

7.30
0.287

12.70
0.500

Part Marking

3.15
0.124

0.51
0.020 (typ)

Pin 1 2 3 4

f 408 225 2079

8.93
0.351

0.25
0.010

p 408 225 4314

10.16
0.400

e www.allsensors.com

CPNS Package

NOTES
1) Dimensions are in inches [mm].
2) For suggested pad layout, see drawing: PAD-01

22.17
0.873

10.16
0.400

Part Marking

1.10
0.043

6.93
0.273

0.64
0.025

1) Gnd
2) +Out
3) Vs
4) -Out

0.51
0.020 (typ)

Pin 1 2 3 4

All Sensors

2.54
0.100 (typ)

Port A

1.27
0.050

6.35
0.250

7.30
0.287

12.70
0.500

1.52
0.060

Port B

3.05
0.120

8.93
0.351

4.35
0.171

5.08
0.200

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

CPPS Package

0.25
0.010

Marking:
right dot: Red: Prime Grade
left dot:
L10: yellow
0.3: pink
1.0: green
05: blue
15: purple
30: orange
100: brown

NOTES
1) Dimensions are in inches [mm].
2) For suggested pad layout, see drawing: PAD-01

DS-0110 Rev E
1-14

Miniature Pressure Sensors


Baromtric Pressure Sensors Prime Grade

Features

all sensors

600 to 1,100 mbar Pressure Range


0.25 % linearity
Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
Weather Station
Altimeters

General Description

e www.allsensors.com

The Miniature series pressure sensors are based upon a proprietary technology to reduce the size of the sensor and yet maintain a
high level of performance. This model provides a calibrated millivolt output with superior output characteristics. In addition the
sensor utilizes a silicon, micromachined (MEMS) structure to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This
series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The PRIME GRADE is

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Supply Voltage VS

Temperature Ranges

16 Vdc

Lead Temperature
(soldering 2-4 sec.)

270C

Compensated

0 to 70 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Equivalent Circuit
+Vsupply

-Vout

+Vout

Input Resittance

15.0 k ohm

Output Resistance

3.0 k ohm

-Vsupply

Approvals
MKT

As Is

DATE

With Change

All Sensors

MFG

As Is

DATE

With Change

ENG

As Is

DS-0039 Rev C

DATE

With Change

QA

As Is

DATE

With Change

01
1-15

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage to 16 volts.

p 408 225 4314

f 408 225 2079

the highest accuracy version of the millivolt output pressure sensors.

Standard Pressure Ranges


Part Number

Operating Range

Proof Pressure

Burst Pressure

BARO-A-PRIME-MINI

600 to 1100 mbar

45 PSI

60 PSI

BARO-AF-PRIME-DIP-MINI

600 to 1100 mbar

45 PSI

60 PSI

BARO-AF-PRIME-MINI

600 to 1100 mbar

45 PSI

60 PSI

Performance Characteristics
BARO-A-PRIME-MINI, BARO-AF-PRIME-DIP-MINI, BARO-AF-PRIME-MINI
Minimum

Nominal

Maximum

Units

Output Voltage @ 1100 mbar

94.7

95.7

96.7

mV

Output Voltage @ 600 mbar

51.2

52.2

53.2

mV

Output Voltage 0 to 1100 mbar

--

0.087

--

mV/mbar

Linearity, hysteresis error, note 3

--

0.05

0.25

%fs

Output Shift (0C-70C), note 2

--

--

%fs

Parameter, note 1

Specification Notes
1: ALL PARAMETERS ARE MEASURED AT 12.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE
PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE

MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.

Miniature Barometric Pressure Sensors


1-15

Physical Dimensions

CFNS Package

10.16
0.400
8.93
0.351

3.15
0.124

5.08
0.200

0.41
R0.016

all sensors

Absolute devices
are without port hole.

6.35
0.250

6.35
0.250

7.30
0.287

0.79
0.031

10.17
0.400
2.54
0.100 (typ)

0.25
0.010

0.51
0.020 (typ)

NOTES
1) Dimensions are in inches [mm].
2) For suggested pad layout, see drawing: PAD-01

Pin 1 2 3 4

e www.allsensors.com

PINOUT:
1: -Vs
2: +Vout
3: +Vs
4: -Vout

CPND Package
Pin 8 7 6 5
10.77
0.424

Port B

0.51
0.020 (typ)

10.16
0.400

10.77
0.424

5.08
0.200

2.54
0.100 (typ)

Pin 1 2 3 4

0.51
0.020 (typ)

3.15
0.124

5.08
0.200

0.64
0.025
0.41
R0.016

Absolute devices
are without port hole.

6.35
0.250

1.27
0.050

4.35
0.171

4.57
0.180

6.35
0.250
0.79
0.031

10.17
0.400

7.30
0.287

Part Marking

12.70
0.500

Absolute devices
are without port hole.

8.07
0.318

NOTES
1) Dimensions are in inches [mm].
2) For suggested pad layout, see drawing: PAD-03

8.93
0.351

All Sensors

15.67
0.617

0.34
0.013

Pin 1 2 3 4

CPNS Package

PINOUT:
1: -Vs
2: +Vout
3: +Vs
4: -Vout

1.12
0.044

p 408 225 4314

2.54
0.100 (typ)

5.08
0.200

6.35
0.250

1.52
0.060

0.64
0.025

0.25
0.010

6.35
0.250

7.30
0.287

PINOUT:
1: -Vs
Pin 1
2: +Vout
Identifier
3: +Vs
(Yellow Paint Dot)
4: -Vout
5: Do Not Connect
6: Do Not Connect
7: Do Not Connect
8: Do Not Connect

12.70
0.500

Part Marking

3.15
0.124

4.35
0.171

5.08
0.200

3.05
0.120

8.93
0.351

f 408 225 2079

10.16
0.400

Port B
0.25
0.010

NOTES
1) Dimensions are in inches [mm].
2) For suggested pad layout, see drawing: PAD-01

DS-0039 Rev C
1-15

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

12.70
0.500

5.08
0.200

0.64
0.025

Part Marking

Digital Output

DLVR Series Low Voltage Digital Pressure Sensors


Features
0.5 to 60 inH2O Pressure Ranges
3.3V Supply Voltage Standard / 5V Option
I2C Standard Interface / SPI Interface Option
Better than 1.0% Accuracy Over Temperature Typical

Applications

General Description

The DLVR Series Mini Digital Output Sensor is based on All Sensors CoBeam2 TM Technology. This reduces package stress
susceptibility, resulting in improved overall long term stability. The technology also vastly improves position sensitivity
compared to single die devices.
The supply voltage options ease integration of the sensors into a wide range of process control and measurement systems, allowing direct connection to serial communications channels. For battery-powered systems, the sensors can enter
very low-power modes between readings to minimize load on the power supply.

Standard Pressure Ranges

Equivalent Circuit

Operating Range

Proof Pressure

Burst Pressure

Nominal Span

DLVR-F50D

0.5 inH2O

100 inH2O

300 inH2O

6,553 counts

DLVR-L01D

1 inH2O

100 inH2O

300 inH2O

6,553 counts

DLVR-L02D

2 inH2O

100 inH2O

300 inH2O

6,553 counts

DLVR-L05D

5 inH2O

200 inH2O

300 inH2O

6,553 counts

DLVR-L10D

10 inH2O

200 inH2O

300 inH2O

6,553 counts

INT

DLVR-L20D

20 inH2O

200 inH2O

500 inH2O

6,553 counts

Gnd

DLVR-L30D

30 inH2O

200 inH2O

500 inH2O

6,553 counts

DLVR-L60D

60 inH2O

200 inH2O

800 inH2O

6,553 counts

DLVR-L01G

0 to 1 inH2O

100 inH2O

300 inH2O

13,107 counts

DLVR-L02G

0 to 2 inH2O

100 inH2O

300 inH2O

13,107 counts

DLVR-L05G

0 to 5 inH2O

200 inH2O

300 inH2O

13,107 counts

DLVR-L10G

0 to 10 inH2O

200 inH2O

300 inH2O

13,107 counts

DLVR-L20G

0 to 20 inH2O

200 inH2O

500 inH2O

13,107 counts

DLVR-L30G

0 to 30 inH2O

200 inH2O

500 inH2O

13,107 counts

DLVR-L60G

0 to 60 inH2O

200 inH2O

800 inH2O

13,107 counts

Pressure Sensor Maximum Ratings


Supply Voltage (Vs)
Common Mode Pressure
Lead Temperature (soldering 2-4 sec.)

SCL
SDA

p 408 225 4314

I2C

Vs
SPI
Option

SCLK
MISO
SS
Gnd

Environmental Specifications
6 Vdc

10 psig
270 C

Temperature Ranges
Compensated:

Commercial
Industrial

Operating
Storage

Humidity Limits (non condensing)

All Sensors

f 408 225 2079

Vs

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Device

e www.allsensors.com

These calibrated and compensated sensors provide accurate, stable output over a wide temperature range. This series
is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. A protective parylene
coating is optionally available for moisture/harsh media protection.

all sensors

Medical Breathing
Environmental Controls
HVAC
Industrial Controls
Portable/Hand-Held Equipment

0C to 70C
-20C to 85C

-25C to 85 C
-40C to 125 C
0 to 95% RH

DS-0300 Rev C

Page 1

2-1

Performance Characteristics for DLVR Series - Commercial and Industrial Temperature Range

All parameters are measured at 3.3V 5% or 5.0V 5% (depending on selected voltage option) excitation and room temperature unless otherwise specified.
Pressure measurements are with positive pressure applied to PORT B.

Parameter

Min

Typ

Max

Units

Output Span

Notes
1

LxxD, FxxD
LxxG

-
-

6,553
13,107

-
-

Dec count
Dec count

8,192
1,638

-
-

Dec count
Dec count

Offset Output @ Zero Diff. Pressure

LxxD, FxxD
LxxG

Total Error Band

F50D
L01x, L02x
L05x, L10x, L20x, L30x, L60x

-
-
-

2.0
1.5
1.0

2.5
2.0
1.5

%Span
%Span
%Span

Span Temperature Shift

F50D, L01x, L02x


L05x, L10x, L20x, L30x, L60x

-
-

0.5
0.2

-
-

%FSS
%FSS

Offset Temperature Shift

F50D, L01x, L02x


L05x, L10x, L20x, L30x, L60x

-
-

0.5
0.2

-
-

%FSS
%FSS

Offset Warm-up Shift

F50D, L01x, L02x


L05x, L10x, L20x, L30x, L60x

-
-

0.25
0.15

-
-

%FSS
%FSS

-
-

0.10
0.05

-
-

%FSS
%FSS

-
-

0.25
0.15

-
-

%FSS
%FSS

Offset Position Sensitivity (1g)

F50D, L01x, L02x


L05x, L10x, L20x, L30x, L60x

Offset Long Term Drift (One Year)

F50D, L01x, L02x


L05x, L10x, L20x, L30x, L60x

Linearity, Hysteresis Error

F50D
LxxD
LxxG

-
-
-

0.30
0.25
0.10

-
-
-

%FSS
%FSS
%FSS

-
-

0.40
1.10

0.50
1.40

ms
ms

-
-
-

0.40
1.30
6.5

1.0
3.1
9.5

ms
ms
ms

-
12

14
13

-
-

bit
bit

-
-

11
2

-
-

bit
C

-
-
-
-

3.5
3.6
0.72
0.5

4.3
4.5
0.90
5.0

mA
mA
mA
uA

-
-
-
-

5.0
5.2
1.1
0.5

6.0
6.2
1.3
5.0

mA
mA
mA
uA

Response Delay

Sleep - Wake Pressure


Sleep - Wake All

Update Rate

Fast
Noise Reduced
Low Power

Digital Resolution

Output Resolution
No Missing Codes

Temperature Output

Resolution
Overall Accuracy

Current Requirement (3.3V Option)

Fast
Noise Reduced
Low Power
Sleep (Idle)

Current Requirement (5.0 Option)


Fast
Noise Reduced
Low Power
Sleep (Idle)

See following page for performance characteristics table notes

DLVR Series Low Voltage Digital Pressure Sensors

Page 2

2-1

I2C / SPI Electrical Parameters for DLVR Series

Symbol

Min

Typ

Max

Units

Notes

Input High Level

80.0

100

% of Vs

Input Low Level

20.0

% of Vs

Output Low Level

10.0

% of Vs

I2C Pull-up Resistor

1000

I2C Load Capacitance on SDA, @ 400 kHz


I2C Input Capacitance (each pin)

- - 200 pF 5

CI2C_IN - - 10.0 pF 5

DLVRTransferFunctions

Specification Notes
note

CSDA

all sensors

Parameter

1: THE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN FULL SCALE DECIMAL COUNTS AND THE OFFSET DECIMAL COUNTS.

NOTE1:PressureOutputTransferFunction:


2
2

Isthesensor14bitdigitaloutput.

e www.allsensors.com

Where,

2 2

Isthespecifieddigitaloffset(gage=1,638anddifferential=8,192)
IsthesensorFullScaleSpanininH2O(gage=FullScalePressure,differential=2
xFullScalePressure)

note

2: TOTAL ERROR BAND COMPRISES OF OFFSET AND SPAN TEMPERATURE AND CALIBRATION ERRORS, LINEARITY AND PRESSURE HYSTERISIS ERRORS, OFFSET WARM-UP SHIFT,
NOTE2:TemperatureOutputTransferFunction:

OFFSET POSITION SENSITIVITY AND LONG TERM OFFSET DRIFT ERRORS.


note

3: SHIFT IS RELATIVE TO 25C.

200
0
2

7: TEMPERATURE
OUTPUT CONVERSION FUNCTION:

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

p 408 225 4314

note

f 408 225 2079

4: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.

note 5: PARAMETER IS CHARACTERIZED AND NOT 100% TESTED.

note 6: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STARIGHT LINE CURVE FIT.
note

All Sensors

DS-0300 Rev C

Page 3

2-1

Device Options
The following is a list of factory programmable options. Consult the factory to learn more about the options.

Interface

I2C and SPI interfaces are available. NOTE: SPI interface is only available with eight (8) lead packages.

Supply Voltage

Devices are characterized at either 3.3V or 5.0V depending on the options selected. It is suggested to select
the option that most closely matches the application supply voltage for best possible performance.

Speed/Power

There are four options of Speed/Power. These are Fast(F), Noise Reduced(N), Low Power(L) and Sleep mode(S).

Fast Mode(F) Is the fastest operating mode where the device operates with continuous sampling at the
fastest internal speed.
Noise Reduced(N): Also operates with continuous samples however the ADC is set for over sampling
for noise reduction. The conversion times are resultantly longer than the Fast(F) mode however, there is
approximately 1/2 bit reduction in noise.
Low Power(L): Is similar to the Fast(F) mode with exception that the device uses an internal timer to
delay between pressure conversions. The internal timer time-out triggers the next conversion cycle. The
update rate is commensurately lower for this mode as a result.
Sleep(S): Is similar to the Low Power(L) mode however the trigger to initiate a sample comes from the
user instead of an internal timer. This is ideal for very low update rate applications that requirelow
power usage. It is also ideal for synchronizing the data conversions with the host microprocessor.

Coating
Parylene Coating: Parylene coating provides a moisture barrier and protection form some harsh media. Consult factory for applicability of Parylene for the target application and sensor type.

DLVR Series Low Voltage Digital Pressure Sensors

Page 4

2-1

Operation Overview
The DLVR is a digital sensor with a signal path that includes a sensing element, a 14 bit analog to digital converter, a DSP and
an IO block that supports either an I2C or SPI interface (see Figure 1 below). The sensor also includes an internal temperature
reference and associated control logic to support the configured operating mode. The sensing element is powered down
while not being sampled to conserve power. Since there is a single ADC, there is also a multiplexer at the front end of the
ADC that selects the signal source for the ADC.
Figure 1 - DLVR Essential Model

Zero

To

1
0

Sensor

P/T/Z
Select

rawP/
rawT

A
D
Sample

Over
Sample
Enable

Pressure

DSP

Control
Logic

Temperature

I/O

I2C/SPI

all sensors

Vs

Wake

There are two effective operating modes of the sensor 1) Free Running and 2) Triggered. The control logic performs the
synchronization of the internal functions according the factory programmed Power/Speed option (see Table 1). The Control
Logic also determines the Delay between ADC samples, the regularity of the Special cycles and whether or not the ADC performs the Over Sampling. Refer to Figure 2 for the communication model associated with the operating modes listed below.
Free Running Mode: In the free running mode, conversion cycles are initiated internally at regular intervals. There are
three options available that operate in the Free Running mode (F, N and L). Two of these (F and N) run continuously while
the third option (L) has an approximate 6 ms delay between conversion cycles. All three options have Special cycles
inserted at regular intervals to accomplish the ADC zeroing and temperature measurements. Two of the options utilize
oversampling. Refer to Table 1 for specific option controls.
Triggered Mode: In the Triggered Mode, a conversion cycle is initiated by the user (or host uP). There are two availabe
methods to wake the sensor from sleep mode. The first method (Wake All) is to wake the sensor and perform all three
measurement cycles (Z, T and P). This provides completely fresh data from the sensor. The second method (Wake P) is
to wake the sensor from sleep and only perform the pressure measurement (P).When using this second method, it is up
to the user to interleave Wake All commands at regular intervals to ensure there is sufficiently up to date temperature
information. Also, the Wake Pressure method is only available from the I2C interface (not available using a SPI interface).

All Sensors

DS-0300 Rev C

Page 5

2-1

f 408 225 2079


p 408 225 4314

The DSP receives the converted pressure and temperature information and applies a multi-order transfer function to
compensate the pressure output. This transfer function includes compensation for span, offset, temperature effects of span,
temperature effects of offset and second order temperautre effects of both span and offset. There is also linearity compensation for gage devices and front to back linearity compensation for differential devices.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

The ADC performs conversions on the raw sensor signal (P), the temperature reference (T) and a zero reference (Z) during an
ADC zero cycle. It also has an oversampling mode for a noise reduced output. A conversion cycle that is mesuring pressure
is called a Normal cycle. A cycle where either a temperature measurement or zeroing is being performed is called a Special
cycle.

e www.allsensors.com

Gnd

Operation Overview (Contd)


Table 1 - DLVR Control Logic Detail
Control Logic
Power/
Speed
Option

Power/Speed
Description

Operating
Over
Mode
Sample

F
N
L

Fast
Noise Reduced
Low Power

Free
Running

Sleep(1) (Wake Pressure)


Sleep (Wake All)

Triggered

No
Yes
Yes
No
No

Delay
Between
Samples

Normal
ADC
Cycles

Special
ADC
Cycles

Special
ADC Cycle
Interval

No
No
Yes
User Defined
User Defined

1 (P)
1 (P)
1 (P)
1 (P)
1 (P)

1 (Z or T)
1 (Z or T)
1 (Z or T)
n/a
2 (Z + T)

255
255
31
Never
Always

Note 1) Wake from sleep with pressure only reading is not available with SPI interface (I2C only).

Figure 2 - DLVR Communication Model


Free Running Mode [(F)ast, (N)oise Reduced and (L)ow Power Option]
Normal Cycle

Cycle Type
Internal Operation DSP

Delay

ADC (P)

Normal Cycle
DSP

Delay

ADC (P)

Special Cycle (1)


DSP

Delay

ADC (P)

ADC (T or Z)

DSP

Delay

ADC (P)

New Data Available


Note 1: See Table 1 for frequency of Special Cycles

Triggered Mode - Wake All [(S)leep Option]


I2C
or
SPI (SS)
Internal Operation

Wake All

Read Data

Wake All

Read Data
Sleep

ADC (Z)

ADC (T)

ADC (P)

Sleep

DSP

ADC (Z)

ADC (T)

ADC (P)

DSP

Sleep

New Data Available

Triggered Mode - Wake Pressure [(S)leep Option]


I2C
Internal Operation

Wake P.
Sleep

Read Data
ADC (P)

DSP

Sleep

Wake P.
ADC (P)

DSP

Sleep

New Data Available

DLVR Series Low Voltage Digital Pressure Sensors

Page 6

2-1

Digital Interface Data Format


For either type of digital interface, the format of data returned from the sensor is the same. The first 16 bits consist of
the 2 Status bits followed by the 14-bit the pressure value. The third byte provides the 8 most significant bits of the measured temperature; the fourth byte provides the 3 least significant bits of temperature, followed by 5 bits of undefined
filler data. With either interface, the host may terminate the transfer after receiving the first two bytes of data from the
sensor, or following the third byte (if just the most-significant 8 bits of temperature are needed). Refer to Table 2 for the
overall data format of the sensor. Table 3 shows the Status Bit definition.

all sensors

Table 2 - Output Data Format

e www.allsensors.com

Bit Definitions:
Status (S): Normal/command / busy / diagnostic
Pressure (P): Digital pressure reading
Temperature (T): Compensated temperature reading
Table 3- Status Bit Definitions

f 408 225 2079

I2C Interface
I2C Communications Overview

p 408 225 4314

The I2C interface uses a set of signal sequences for communication. The following is a description of the supported
sequences and their associated pneumonic. Refer to Figure 3 for the associated usage of the following signal sequences.
Bus not Busy (I): During idle periods both data line (SDA) and clock line (SCL) remain HIGH.
START condition (ST): A HIGH to LOW transition of SDA line while the clock (SCL) is HIGH is interpreted as
START condition. START conditions are always set by the master. Each initial request for a pressure value has to
begin with a START condition.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Slave address (An): The IC-bus requires a unique address for each device. The DLVR sensor has a preconfigured slave address (0x28). After setting a START condition the master sends the address byte containing the
7 bit sensor address followed by a data direction bit (R/W). A "0" indicates a transmission from master to slave
(WRITE), a "1" indicates a datarequest (READ).
Acknowledge (A or N): Data is transferred in units of 8 bits (1 byte) at a time, MSB first. Each data-receiving
device, whether master or slave, is required to pull the data line LOW to acknowledge receipt of the data. The
Master must generate an extra clock pulse for this purpose. If the receiver does not pull the data line down, a
NACK condition exists, and the slave transmitter becomes inactive. The master determines whether to send
the last command again or to set the STOP condition, ending the transfer.
DATA valid (Dn): State of data line represents valid data when, after a START condition, data line is stable for
duration of HIGH period of clock signal. Data on line must be changed during LOW period of clock signal.
There is one clock pulse per data bit.
DATA operation: The sensor starts to send 4 data bytes containing the current pressure and temperature values. The transmission may be halted by the host after any of the bytes by responding with a NACK.
STOP condition (P): LOW to HIGH transition of the SDA line while clock (SCL) is HIGH indicates a STOP condition. STOP conditions are always generated by the master.

All Sensors

DS-0300 Rev C

Page 7

2-1

I2C Communications Overview (Contd)


Figure 3 - I2C Communication Diagram
I2C Communications Diagram
1. Start All ( to wake sensor from Sleep mode, Zero ADC, read Temperature and read Pressure )
SP I
Set by bus master: -I - - ST
- A6 A5 A4 A3 A2 A1 A0 R
Set by sensor: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A- - - - - - - - -

2. Start Pressure ( to wake sensor from Sleep mode and read Pressure only )
SP I
Set by bus master: -I - - ST
- A6 A5 A4 A3 A2 A1 A0 W
Set by sensor: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A- - - - - - - - -

3. Read Data ( with examples of reading pressure, pressure plus 8 bits of temperature and pressure plus 11 bits of temperature )
A
Set by bus master: -I - - ST
- A6 A5 A4 A3 A2 A1 A0 R
D23 D16
Set by sensor ( pressure plus status ): - - - - - - - - - - - -A- -D31
- - -- -D24
then, one of the following:
a) Set by bus master, to stop transfer after pressure data received: - - - - - - - - - - - - - -N- - -SP
- - - I- - - --OR-b) Set by bus master, to stop transfer after first temperature data byte received: - - - - -A- - - - - - - - - N SP I
Set by sensor ( high order 8 bits of temperature ): - - - - - - - - - - - - - - - - - - - - - - - - - - - D15
- - - -
- - -D8
--OR-A
N SP I
c) Set by bus master, to stop transfer after last temperature data byte received: - - - - - A- - - - - - - - D7 D0
Set by sensor ( all 11 bits of temperature plus padding bits ): - - - - - - - - - - - - - - - - - - - D15
- - - -
- - -D8
-

Bus states
Idle:
Start:
Stop:
Ack:
Nack:
Read bit (1):
Write bit (0):

I
ST
SP
A
N
R
W

Sensor Address
A6 A0

Default: 0x28

Data format
Status:
Pressure data:
Temperature data:
(padding bits:)

D31
D29
D15
D4

D30
D16
D5
D0

Figure 3 illustrates the sequence of signals set by both the host and the sensor for each command. Note that for the DataRead command, the host has the option of responding to the second or third bytes of data with a NACK instead of ACK.
This terminates the data transmission after the pressure data, or after the pressure data and upper byte of temperature,
have been transmitted. See Figure 6 for the I2C timing details.

DLVR Series Low Voltage Digital Pressure Sensors

Page 8

2-1

I2C Command Sequence


Depending on whether the Fast, Noise Reduced, Low-Power, or Sleep options have been selected, the command sequence differs slightly. See Figure 3 for details of the three I2C commands.

The part enters Triggered mode (see table 1) after power-up, and waits for a command from the bus master. If
the StartAll command is received, the temperature, ADC zero, and pressure readings are all measured, and correction calculations are performed. When valid data is written to the output registers, the INT pin is set high,
and the processing core goes back to sleep. The host processor then sends the DataRead command to shift
out the updated values. If the INT pin is not monitored, the host can poll the output registers by repeating
the DataRead command until the Status bits indicate that the values have been updated (see Tables 2 and 3).
The response time depends on configuration options (refer to Table 1 and Performance Characteristics).
Depending on the application, pressure measurements may be performed by sending the StartPressure command, which only measures the pressure value and uses previously measured temperature data in calculating
the compensated output value. This presents the result faster (in about 1/3 the delay time) than the StartAll
command. This can be a useful method to synchronize the sensor with the hose controller as well as attaining the fastest overall response time without Special cycles occuring at unwanted times. The system designer
should determine the interval required for sending StartAll commands, necessary to refresh the temperature

p 408 225 4314

I2C Exceptions
1. Sending a Start condition, then a Stop condition, without any transitions on the CLK line, creates a communication error for the next communication, even if the next start condition is correct and the clock pulse is
applied. A second Start condition must be set, which clears the error and allows communication to proceed.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

2. The Restart conditiona falling SDA edge during data transmission when the CLK clock line is still high
creates the same stall/deadlock. In the following data request, an additional Start condition must be sent for
correct communication.
3. A falling SDA edge is not allowed between the start condition and the first rising SCL edge. If using an I2C
address with the first bit 0, SDA must be held low from the start condition through the first bit.

All Sensors

DS-0300 Rev C

Page 9

e www.allsensors.com

Sleep Configuration

f 408 225 2079

The part enters Free Running mode (see table 1) after power-up: it performs an initial complete measurement,
writes the calculated data to the output registers, sets the INT pin high, then goes to sleep. After a delay determined by the update rate option, the part will wake up, perform measurements, update the output registers,
then go back to sleep. DataRead is the only command recognized; as with the Micropower configuration, if
the INT pin is ignored, the host processor can repeat this command until the Status bits indicate an updated
reading.

all sensors

Fast, Noise Reduced or Low-power Configuration

2-1

SPI Interface
SPI Command Sequence
DLVR sensors using the SPI interface option provide 3 signals for communication: SCLK, SS (Slave Select), and MISO.
This read-only signaling uses a hardware protocol to control the sensor, differing slightly with the speed/power option
selected as described below:
Fast(F), Noise Reduced(N) and Low-Power(L) Configurations: After power-up, the part enters Free Running
mode and begins its periodic conversion cycle, at the interval determined by the programmed Power/Speed
option. This is the simplest configuration. The only bus interaction with the host is the SPI DataRead operations. Polling the sensor at a rate slower than the internal update rate will minimize bus activity and ensure
that new values are presented with each transfer. Note that the Status bits should still be checked to verify
updated data and the absence of error conditions.
Sleep(S) Configuration: As with the I2C option, the part enters Triggered mode after power-up, and waits for
a command from the bus master. To wake the part and start a measurement cycle, the SS pin must be driven
low by the host for at least 8usec, then driven high. This can be done by shifting a dummy byte of 8 bits from
the sensor. This bus activity can be considered the SPI StartAll command, where the rising edge of SS is the
required input to start conversion. Updated conversion data is written to the output registers after a period
dependent on configuration options ( see Performance Characteristics). After this update of the registers, the
core goes to an inactive (sleep) state. The DataRead command simply consists of shifting out 2, 3, or 4 bytes
of data from the sensor. The host can check the Status bits of the output to verify that new data has been
provided. The part remains inactive following this read operation, and another StartAll operation is needed to
wake the part when the next conversion is to be performed.

SPI Bit Pattern


The sequence of bits and bus signals are shown in the following illustration (Figure 4). Refer to Figure 5 in the Interface
Timing Diagram section for detailed timing data. As previously described, the incoming data may be terminated by raising SS after 2, 3, or 4 bytes have been received as illustrated below.

Figure 4 - SPI Bit Pattern

DLVR Series Low Voltage Digital Pressure Sensors

Page 10

2-1

Interface Timing Diagrams

Figure 5 - SPI Timing Diagram


tSCLK
tLOW

tSSCLK

tHIGH

MISO

(HIZ)

all sensors

SCLK
(HIZ)

tCLKD

tCLKD

SS
tCLKSS
MIN

f SCLK
f SCLK

50
50
2.5
0.6
0.6
0
0.1
2

tSSCLK
tLOW
tHIGH
tCLKD
tCLKSS
tIDLE

TYP

MAX

UNITS

800
200

kHz
kHz

0.1

e www.allsensors.com

S YMBOL

us
us
us
us
us
us

f 408 225 2079

P ARAMETER

S CLK clock frequency (4MHz clock)


S CLK clock frequency (1MHz clock)
S S drop to firs t clock edge
Minimum S CLK clock low width
Minimum S CLK clock high width
Clock edge to data trans ition
Ris e of S S relative to las t clock edge
Bus free time between ris e and fall of S S

tIDLE

tH STA

tHIGH

p 408 225 4314

Figure 6 - I2C Timing Diagram

tLOW

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

SCL
SDA
tSUSTA

tSUDAT

P ARAMETER

S CL clock frequency
S tart condition hold time relative to S CL edge
Minimum S CL clock low width
Minim um S CL clock high width

S tart condition s etup time relative to S CL edge


Data hold time on S DA relative to S CL edge
Data s etup time on S DA relative to S CL edge
S top condition s etup time on S CL
Bus free time between s top condition and s tart cond .

All Sensors

tH DAT

tSUSTP

S YMBOL

MIN

fSCL
tHSTA
tLOW
tHIGH
tSUSTA
tHDA T
tSUDA T
tSUSTP
tIDLE

100
0.1
0.6
0.6
0.1
0
0.1
0.1
2

TYP

tIDLE
MAX

UNITS

400

kHz
us
us
us
us
us
us
us
us

DS-0300 Rev C

Page 11

2-1

How to Order
Refer to Table 4 for configuring a standard base part number which includes the pressure range, package and
temperature range. Table 5 shows the available configuring options. The option identifier is required to complete
the device part nubmer. Refer to Table 6 for the available devices packages.
Example P/N with options: DLVR-L02D-E1NS-C-NI3F
Table 4 - How to configure a base part number

ORDERING INFORMATION

SERIES

PRESSURE RANGE

ID
DLVR

ID
F50D
L01D
L02D
L05D
L10D
L20D
L30D
L60D
L01G
L02G
L05G
L10G
L20G
L30G
L60G

Description
0.5 inH2O
1 inH2O
2 inH2O
5 inH2O
10 inH2O
20 inH2O
30 inH2O
60 inH2O
0 to 1 inH2O
0 to 2 inH2O
0 to 5 inH2O
0 to 10 inH2O
0 to 20 inH2O
0 to 30 inH2O
0 to 60 inH2O

Example DLVR - L02D

Base
ID
E

- E

Port Orientation
ID Description
1 Dual Port Same Side
2 Dual Port Opposite Side

ID
N
B

PACKAGE
Lid Style
Description
Non-Barbed
Barbed

TEMPERATURE RANGE
ID
S
D
J

Lead Type
Description
SIP
DIP
J-Lead SMT

ID
C
I

Description
Commercial
Industrial

ORDERING
INFORMATION

Table 5 - How to configure an option identifier


COATING
ID Description
N No Coating
P Parylene Coating 8

Example N

INTERFACE
ID Description
I I2C
S SPI

SUPPLY VOLTAGE
ID Description
3 3.3V
5 5.0V

SPEED/POWER
ID Description
F Fast
N Noise reduced
L Low Power
S Sleep Mode

TABLE 6: Available E-Series Package Configurations


Port
Orientation

Non-Barbed Lid
Lead Style
SIP

DIP

J Lead SMT

Dual Port
Same Side

Low Prole DIP

SIP

DIP

N/A

E1NS

E1ND

E1NJ

Dual Port
Opposite
Side

Single Port
(Gage)

Barbed Lid
Lead Style

E1BS

E2ND

E2NJ

N/A

N/A

N/A

N/A

Low Prole DIP

N/A

N/A

N/A

N/A

N/A

N/A

E1BD

N/A

E2NS

J Lead SMT

E2BS

E2BD

N/A

N/A

Specification Notes (Cont.)


note 8: PARYLENE COATING NOT OFFERED IN J-LEAD SMT CONFIGURATION.

DLVR Series Low Voltage Digital Pressure Sensors

Page 12

2-1

Package Drawings
E1NS Package

Pinout
1) Gnd
2) Vs
3) SDA
4) SCL

7.17
0.282

12.70
0.500

0.64
0.025

10.79
0.425

2.10
0.082

all sensors

4.88
0.192

2.04
0.080

10.79
0.425

Port A

0.25
0.010

0.51
0.020

e www.allsensors.com

2.73
0.107

[9.65]
0.380 (nom)

6.45
0.254

9.80
0.386

15.75
0.620

Port B

2.54
0.100

Pin 1 2 3 4

E1BS Package

f 408 225 2079

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

Pinout

Port A

2.73
0.107

[9.65]
0.380 (nom)
0.25
0.010

0.51
0.020

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

1.68
0.066

10.80
0.425

Port B

6.45
0.254

9.80
0.386

1.14
0.045

10.80
0.425

15.75
0.620

0.64
0.025

2.11
0.083

12.70
0.500

4.88
0.192

2.24
0.088

9.15
0.360

p 408 225 4314

1) Gnd
2) Vs
3) SDA
4) SCL

2.54
0.100

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

All Sensors

DS-0300 Rev C

Page 13

2-1

Package Drawings (Contd)


E2NS Package

Pinout
1) Gnd
2) Vs
3) SDA
4) SCL

7.17
0.282

0.64
0.025
2.12
0.084

12.70
0.500
10.79
0.425

Port A

2.10
0.082

2.04
0.080

10.79
0.425
2.73
0.107

[9.65]
0.380 (nom)

9.80
0.386

15.75
0.620

Port B

0.25
0.010

2.54
0.100

0.51
0.020

Pin 1 2 3 4

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

E2BS Package

Pinout
1) Gnd
2) Vs
3) SDA
4) SCL

2.12
0.084

Port B

2.73
0.107

1.68
0.066

10.80
0.425

15.75
0.620
[9.65]
0.380 (nom)

9.80
0.386

1.14
0.045

10.80
0.425

Port A

0.25
0.010

2.11
0.083

12.70
0.500

2.24
0.088

9.15
0.360

0.64
0.025

0.51
0.020

2.54
0.100

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

DLVR Series Low Voltage Digital Pressure Sensors

Page 14

2-1

Package Drawings (Contd)


E1ND Package

Pinout

5.72
0.225

Pin 8 7 6 5

7.17
0.282
0.64
0.025

all sensors

0.46
0.018

1) Gnd
2) Vs
3) SDA/MISO
4) SCL/SCLK
5) INT/SS
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

12.70
0.500

4.88
0.192

10.79
0.425

2.10
0.082

e www.allsensors.com

2.04
0.080

10.79
0.425

15.75
0.620

6.45
0.254

2.73
0.107

Port A
2.54
0.100

8.89
0.350
(min)

Pin 1 2 3 4

E1BD Package

f 408 225 2079

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

0.25
0.010

1.48
0.058

9.80
0.386

16
0.630

Port B

Pinout

Pin 8 7 6 5

9.15
0.360
0.64
0.025

12.70
0.500

4.88
0.192

p 408 225 4314

5.72
0.225

2.11
0.083
1.14
0.045

10.80
0.425

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

0.46
0.018

1) Gnd
2) Vs
3) SDA/MISO
4) SCL/SCLK
5) INT/SS
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

All Sensors

8.89
0.350
(min)

2.24
0.088

1.68
0.066

10.80
0.425

15.75
0.620

16
0.630
6.45
0.254

Port A

2.73
0.107

0.25
0.010

1.48
0.058

9.80
0.386

Port B

2.54
0.100

Pin 1 2 3 4

DS-0300 Rev C

Page 15

2-1

Package Drawings (Contd)


E2ND Package

Pinout

0.46
0.018

1) Gnd
2) Vs
3) SDA/MISO
4) SCL/SCLK
5) INT/SS
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

5.72
0.225

7.17
0.282

Pin 8 7 6 5

0.64
0.025

12.70
0.500

2.12
0.084

10.79
0.425

Port A

2.10
0.082

2.04
0.080

10.79
0.425
2.73
0.107

8.89
0.350
(min)

1.48
0.058

15.75
0.620

0.25
0.010

9.80
0.386

16
0.630

Port B

2.54
0.100

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

Pin 1 2 3 4

E2BD Package

Pinout

0.46
0.018

1) Gnd
2) Vs
3) SDA/MISO
4) SCL/SCLK
5) INT/SS
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

5.72
0.225

Pin 8 7 6 5

9.15
0.360

12.70
0.500

0.64
0.025

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

1.68
0.066

10.80
0.425

15.75
0.620

Port B

2.73
0.107

0.25
0.010

1.48
0.058

9.80
0.386

16
0.630

Port A

8.89
0.350
(min)

1.14
0.045

10.80
0.425

2.24
0.088

2.12
0.084

2.11
0.083

2.54
0.100

Pin 1 2 3 4

DLVR Series Low Voltage Digital Pressure Sensors

Page 16

2-1

Package Drawings (Contd)


E1NJ Package

Pinout

Pin 8 7 6 5

7.17
0.282
0.64
0.025

all sensors

1) Gnd
2) Vs
3) SDA/MISO
4) SCL/SCLK
5) INT/SS
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

12.70
0.500

4.88
0.192

2.10
0.082

10.79
0.425

e www.allsensors.com

15.75
0.620

2.04
0.080

Port A

2.73
0.107

DETAIL A
SCALE 4 : 1

6.45
0.254

9.80
0.386

1.27
0.050

2.54
0.100

Pin 1 2 3 4

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-10

E2NJ Package

f 408 225 2079

1.51
0.059

3.94
0.155

0.81
R0.032

10.79
0.425

Port B
0.25
0.010

Pinout

Pin 8 7 6 5

7.17
0.282

2.10
0.082

12.70
0.500
10.79
0.425

Port A

0.64
0.025

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

2.12
0.084

p 408 225 4314

1) Gnd
2) Vs
3) SDA/MISO
4) SCL/SCLK
5) INT/SS
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

2.04
0.080

10.79
0.425

16
0.630

2.73
0.107

DETAIL A
SCALE 4 : 1

9.80
0.386

1.51
0.059

3.94
0.155

0.81
R0.032

15.75
0.620

Port B
0.25
0.010

1.27
0.050

2.54
0.100

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-10

All Sensors

DS-0300 Rev C

Page 17

2-1

2.29
0.090

2.54
0.100
(typ.)

0.035~0.039 inch
(Finish Size)

2.54
0.100
(typ.)

1.27
0.050

0.035~0.039 inch
(Finished Size)

2.54
0.100
(typ.)

Suggested Pad Layout

16
0.630

PAD-01

PAD-03

14.99
0.590

PAD-10

Product Labeling

All Sensors
DLVR-L02D
E1NS-C
NI3F
R9J21-3

Company
Part Number
Lot Number

Example Device Label

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

DLVR Series Low Voltage Digital Pressure Sensors

Page 18

2-1

DLV Series Low Voltage Digital Pressure Sensors


Features
5 to 60 psi Pressure Ranges
3.3V or 5.0V Supply Voltage
I2C or SPI Interface
Better than 0.5% Accuracy Over Temperature Typical
Die Sil-Gel Coating for Enhanced Media Protection

Applications
Medical Breathing
Environmental Controls
HVAC
Industrial Controls
Portable/Hand-Held Equipment

General Description

all sensors

The DLV Series Mini Digital Output Sensor is based on the already popular DLVR series pressure sensors. This series
offers excellent performance over middle pressure ranges of 5 psi to 60 psi compared to the DLVR low pressure
range products.
The supply voltage options ease integration of the sensors into a wide range of process control and measurement
systems, allowing direct connection to either I2C or SPI serial communications channels. For battery-powered systems, the sensors can enter very low-power modes between readings to minimize load on the power supply.

Standard Pressure Ranges


Proof Pressure

Burst Pressure

Nominal Span

DLV-005G

0 to 5 PSI

DLV-015G

0 to 15 PSI

20 PSI

40 PSI

13,107 counts

60 PSI

120 PSI

13,107 counts

DLV-015A

0 to 15 PSIA

60 PSI

120 PSI

13,107 counts

DLV-030G

0 to 30 PSI

120 PSI

200 PSI

13,107 counts

DLV-030A

0 to 30 PSIA

120 PSI

200 PSI

13,107 counts

DLV-060G

0 to 60 PSI

200 PSI

200 PSI

13,107 counts

DLV-060A

0 to 60 PSIA

200 PSI

200 PSI

13,107 counts

Vs

f 408 225 2079

Operating Range

Equivalent Circuit

SCL
I2C

SDA
INT

p 408 225 4314

Device

e www.allsensors.com

These calibrated and compensated sensors provide accurate, stable output over a wide temperature range. This
series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. A SIl-Gel
die coating is added for enhanced media protection.

Gnd
Vs

SPI

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

SCLK
MISO
SS
Gnd

Pressure Sensor Maximum Ratings


Supply Voltage (Vs)
Common Mode Pressure
Lead Temperature (soldering 2-4 sec.)

Environmental Specifications
6 Vdc

10 psig
270 C

Temperature Ranges
Compensated:

Commercial
Industrial

Operating
Storage

Humidity Limits (non condensing)

All Sensors

0C to 70C
-20C to 85C

-25C to 85 C
-40C to 125 C
0 to 95% RH

DS-0336 Rev B

Page 1

2-2

Performance Characteristics for DLV Series - Commercial and Industrial Temperature Range
All parameters are measured at 3.3V 5% or 5.0V 5% (depending on selected voltage option) excitation and room temperature unless
otherwise specified. Pressure measurements are with positive pressure applied to PORT B.

Parameter
Output Span

Min
-

Typ
13,107

Max
-

Units Notes
Dec Count

Offset Output
xxxG (at 0 PSIG)
-
1,638
-
Dec Count
xxxA (at 0 PSIA)
-
1,638
-
Dec Count
Total Error Band
-
0.5
1.0
%FSS
2
Span Temperature Shift
-
0.1
-
%FSS
3
Offset Temperature Shift

0.1

%FSS

Offset Warm-up Shift

0.1

%FSS

Offset Long Term Drift (One Year)


-
0.1
-
%FSS
Linearity, Hysteresis Error
0.1
0.25
%FSS
6
Response Delay
5
Sleep - Wake Pressure
-
0.40
0.50
ms
Sleep - Wake All
-
1.10
1.40
ms
Update Rate
5
Fast
Noise Reduced
Low Power
Start-up Time

-
-
-
-

0.40
1.30
6.5
-

1.0
3.1
9.5
10.0

ms
ms
ms
ms

5, 7

Digital Resolution
5
Output Resolution
-
14
-
bit
No Missing Codes
12
13
-
bit
Temperature Output
8

Resolution
- 11 - bit

Overall Accuracy
- 2 - C
Current Requirement (3.3V Option)
5
Fast
-
2.5
3.2
mA
Noise Reduced
-
2.5
3.1
mA
Low Power
-
0.6
0.7
mA
Sleep (Idle)
-
0.5
5.0
uA
Current Requirement (5.0 Option)
Fast
-
3.5
4.5
mA
Noise Reduced
-
3.6
4.4
mA
Low Power
-
0.8
1.0
mA
Sleep (Idle)
-
0.5
5.0
uA

See the following page for performance characteristics table notes.

DLV Series Low Voltage Digital Pressure Sensors

Page 2

2-2

I2C / SPI Electrical Parameters for DLV Series

Parameter

Symbol Min Typ Max Units Notes

Input High Level

80.0

100

% of Vs

Input Low Level

20.0

% of Vs

Output Low Level

10.0

% of Vs

I2C Pull-up Resistor

1000

I2C Load Capacitance on SDA, @ 400 kHz

- - 200 pF 5

CI2C_IN - - 10.0 pF 5

all sensors

I2C Input Capacitance (each pin)

CSDA

Specification Notes
note

1: THE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN FULL SCALE DECIMAL COUNTS AND THE OFFSET DECIMAL COUNTS.

Pressure Output Transfer

Where,

e www.allsensors.com

2
Is the sensor 14 bit digital output.
Is the

digital

(gage and absolute = 1,638)

Is the sensor Full Scale Span in psi.

note

2: TOTAL ERROR BAND COMPRISES OF OFFSET AND SPAN TEMPERATURE AND CALIBRATION ERRORS, LINEARITY AND PRESSURE HYSTERESIS ERRORS, OFFSET WARM-UP

note

3: SHIFT IS RELATIVE TO 25C.

note

4: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.

note

5: PARAMETER IS CHARACTERIZED AND NOT 100% TESTED.

note

6: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.

note

7: POWER-ON TIME IS TIME FROM POWER BEING APPLIED TO FIRST AVAILABLE PART COMMUNICATIONS.

note

8: TEMPERATURE OUTPUT CONVERSION FUNCTION:

p 408 225 4314

f 408 225 2079

SHIFT AND LONG TERM OFFSET DRIFT ERRORS.

Temperature Output Transfer


200

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

All Sensors

DS-0336 Rev B

Page 3

2-2

Device Options
The following is a list of factory programmable options. Consult the factory to learn more about the options.

Interface

I2C and SPI interfaces are available. NOTE: SPI interface is only available with eight (8) lead packages.

Supply Voltage

Devices are characterized at either 3.3V or 5.0V depending on the options selected. It is suggested to
select the option that most closely matches the application supply voltage for best possible performance.

Speed/Power

There are four options of Speed/Power. These are Fast(F), Noise Reduced(N), Low Power(L) and Sleep
mode(S).
Fast Mode(F) Is the fastest operating mode where the device operates with continuous sampling at
the fastest internal speed.
Noise Reduced(N): Also operates with continuous samples however the ADC is set for over sampling
for noise reduction. The conversion times are resultantly longer than the Fast(F) mode however, there
is approximately 1/2 bit reduction in noise.
Low Power(L): Is similar to the Fast(F) mode with exception that the device uses an internal timer to
delay between pressure conversions. The internal timer time-out triggers the next conversion cycle.
The update rate is commensurately lower for this mode as a result.
Sleep(S): Is similar to the Low Power(L) mode however the trigger to initiate a sample comes from the
user instead of an internal timer. This is ideal for very low update rate applications that require low
power usage. It is also ideal for synchronizing the data conversions with the host microprocessor.

Coating
Parylene Coating: Parylene coating provides a moisture barrier and protection form some harsh media.
The DLV Series includes a Sil-Gel die coating for enhanced media protection however for additional
protection, a Parylene coating may at times be beneficial. Consult factory for applicability of Parylene for
the target application and sensor type.

DLV Series Low Voltage Digital Pressure Sensors

Page 4

2-2

Operation Overview
The DLV is a digital sensor with a signal path that includes a sensing element, a 14 bit analog to digital converter, a DSP
and an IO block that supports either an I2C or SPI interface (see Figure 1 below). The sensor also includes an internal
temperature reference and associated control logic to support the configured operating mode. The sensing element is
powered down while not being sampled to conserve power. Since there is a single ADC, there is also a multiplexer at
the front end of the ADC that selects the signal source for the ADC.
Figure 1 - DLV Essential Model

Zero

To

1
0

Sensor

P/T/Z
Select

rawP/
rawT

A
D
Sample

Over
Sample
Enable

Pressure

DSP

Control
Logic

Temperature

I/O

I2C/SPI

all sensors

Vs

Wake

e www.allsensors.com

Gnd

f 408 225 2079

The ADC performs conversions on the raw sensor signal (P), the temperature reference (T) and a zero reference (Z) during an ADC zero cycle. It also has an oversampling mode for a noise reduced output. A conversion cycle that is mesuring pressure is called a Normal cycle. A cycle where either a temperature measurement or zeroing is being performed
is called a Special cycle.

p 408 225 4314

The DSP receives the converted pressure and temperature information and applies a multi-order transfer function to
compensate the pressure output. This transfer function includes compensation for span, offset, temperature effects of
span, temperature effects of offset and second order temperautre effects of both span and offset. There is also linearity
compensation for all devices.
There are two effective operating modes of the sensor 1) Free Running and 2) Triggered. The control logic performs the
synchronization of the internal functions according the factory programmed Power/Speed option (see Table 1). The
Control Logic also determines the Delay between ADC samples, the regularity of the Special cycles and whether or not
the ADC performs the Over Sampling. Refer to Figure 2 for the communication model associated with the operating
modes listed below.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Free Running Mode: In the free running mode, conversion cycles are initiated internally at regular intervals. There
are three options available that operate in the Free Running mode (F, N and L). Two of these (F and N) run continuously while the third option (L) has an approximate 6 ms delay between conversion cycles. All three options
have Special cycles inserted at regular intervals to accomplish the ADC zeroing and temperature measurements.
Two of the options utilize oversampling. Refer to Table 1 for specific option controls.
Triggered Mode: In the Triggered Mode, a conversion cycle is initiated by the user (or host uP). There are two
availabe methods to wake the sensor from sleep mode. The first method (Wake All) is to wake the sensor and
perform all three measurement cycles (Z, T and P). This provides completely fresh data from the sensor. The
second method (Wake P) is to wake the sensor from sleep and only perform the pressure measurement (P).When
using this second method, it is up to the user to interleave Wake All commands at regular intervals to ensure there
is sufficiently up to date temperature information. Also, the Wake Pressure method is only available from the I2C
interface (not available using a SPI interface).

All Sensors

DS-0336 Rev B

Page 5

2-2

Operation Overview (Contd)


Table 1 - DLV Control Logic Detail
Control Logic
Power/
Speed
Option

Power/Speed
Description

Operating
Over
Mode
Sample

F
N
L

Fast
Noise Reduced
Low Power

Free
Running

Sleep(1) (Wake Pressure)


Sleep (Wake All)

Triggered

No
Yes
Yes
No
No

Delay
Between
Samples

Normal
ADC
Cycles

Special
ADC
Cycles

Special
ADC Cycle
Interval

No
No
Yes
User Defined
User Defined

1 (P)
1 (P)
1 (P)
1 (P)
1 (P)

1 (Z or T)
1 (Z or T)
1 (Z or T)
n/a
2 (Z + T)

255
255
31
Never
Always

Note 1) Wake from sleep with pressure only reading is not available with SPI interface (I2C only).

Figure 2 - DLV Communication Model


Free Running Mode [(F)ast, (N)oise Reduced and (L)ow Power Option]
Normal Cycle

Cycle Type
Internal Operation DSP

Delay

ADC (P)

Normal Cycle
DSP

Delay

ADC (P)

Special Cycle (1)


DSP

Delay

ADC (P)

ADC (T or Z)

DSP

Delay

ADC (P)

New Data Available


Note 1: See Table 1 for frequency of Special Cycles

Triggered Mode - Wake All [(S)leep Option]


I2C
or
SPI (SS)
Internal Operation

Wake All

Read Data

Wake All

Read Data
Sleep

ADC (Z)

ADC (T)

ADC (P)

Sleep

DSP

ADC (Z)

ADC (T)

ADC (P)

DSP

Sleep

New Data Available

Triggered Mode - Wake Pressure [(S)leep Option]


I2C
Internal Operation

Wake P.
Sleep

Read Data
ADC (P)

DSP

Sleep

Wake P.
ADC (P)

DSP

Sleep

New Data Available

DLV Series Low Voltage Digital Pressure Sensors

Page 6

2-2

Digital Interface Data Format


For either type of digital interface, the format of data returned from the sensor is the same. The first 16 bits consist
of the 2 Status bits followed by the 14-bit the pressure value. The third byte provides the 8 most significant bits of
the measured temperature; the fourth byte provides the 3 least significant bits of temperature, followed by 5 bits of
undefined filler data. With either interface, the host may terminate the transfer after receiving the first two bytes of
data from the sensor, or following the third byte (if just the most-significant 8 bits of temperature are needed). Refer
to Table 2 for the overall data format of the sensor. Table 3 shows the Status Bit definition.

all sensors

Table 2 - Output Data Format

e www.allsensors.com

Bit Definitions:
Status (S): Normal/command / busy / diagnostic
Pressure (P): Digital pressure reading
Temperature (T): Compensated temperature reading
Table 3- Status Bit Definitions

f 408 225 2079

I2C Interface
I2C Communications Overview

p 408 225 4314

The I2C interface uses a set of signal sequences for communication. The following is a description of the supported sequences and their associated pneumonic. Refer to Figure 3 for the associated usage of the following signal
sequences.
Bus not Busy (I): During idle periods both data line (SDA) and clock line (SCL) remain HIGH.
START condition (ST): A HIGH to LOW transition of SDA line while the clock (SCL) is HIGH is interpreted
as START condition. START conditions are always set by the master. Each initial request for a pressure
value has to begin with a START condition.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Slave address (An): The IC-bus requires a unique address for each device. The DLV sensor has a preconfigured slave address (0x28). After setting a START condition the master sends the address byte containing
the 7 bit sensor address followed by a data direction bit (R/W). A "0" indicates a transmission from master
to slave (WRITE), a "1" indicates a datarequest (READ).
Acknowledge (A or N): Data is transferred in units of 8 bits (1 byte) at a time, MSB first. Each data-receiving device, whether master or slave, is required to pull the data line LOW to acknowledge receipt of the
data. The Master must generate an extra clock pulse for this purpose. If the receiver does not pull the data
line down, a NACK condition exists, and the slave transmitter becomes inactive. The master determines
whether to send the last command again or to set the STOP condition, ending the transfer.
DATA valid (Dn): State of data line represents valid data when, after a START condition, data line is stable
for duration of HIGH period of clock signal. Data on line must be changed during LOW period of clock
signal. There is one clock pulse per data bit.
DATA operation: The sensor starts to send 4 data bytes containing the current pressure and temperature
values. The transmission may be halted by the host after any of the bytes by responding with a NACK.
STOP condition (P): LOW to HIGH transition of the SDA line while clock (SCL) is HIGH indicates a STOP
condition. STOP conditions are always generated by the master.

All Sensors

DS-0336 Rev B

Page 7

2-2

I2C Communications Overview (Contd)

Figure 3 - I2C Communication Diagram


I2C Communications Diagram
1. Start All ( to wake sensor from Sleep mode, Zero ADC, read Temperature and read Pressure )
SP I
Set by bus master: -I - - ST
- A6 A5 A4 A3 A2 A1 A0 R
Set by sensor: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A- - - - - - - - -

2. Start Pressure ( to wake sensor from Sleep mode and read Pressure only )
SP I
Set by bus master: -I - - ST
- A6 A5 A4 A3 A2 A1 A0 W
Set by sensor: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A- - - - - - - - -

3. Read Data ( with examples of reading pressure, pressure plus 8 bits of temperature and pressure plus 11 bits of temperature )
A
Set by bus master: -I - - ST
- A6 A5 A4 A3 A2 A1 A0 R
D23 D16
Set by sensor ( pressure plus status ): - - - - - - - - - - - -A- -D31
- - -- -D24
then, one of the following:
a) Set by bus master, to stop transfer after pressure data received: - - - - - - - - - - - - - -N- - -SP
- - - I- - - --OR-b) Set by bus master, to stop transfer after first temperature data byte received: - - - - -A- - - - - - - - - N SP I
Set by sensor ( high order 8 bits of temperature ): - - - - - - - - - - - - - - - - - - - - - - - - - - - D15
- - - -
- - -D8
--OR-A
N SP I
c) Set by bus master, to stop transfer after last temperature data byte received: - - - - - A- - - - - - - - D7 D0
Set by sensor ( all 11 bits of temperature plus padding bits ): - - - - - - - - - - - - - - - - - - - D15
- - - -
- - -D8
-

Bus states
Idle:
Start:
Stop:
Ack:
Nack:
Read bit (1):
Write bit (0):

I
ST
SP
A
N
R
W

Sensor Address
A6 A0

Default: 0x28

Data format
Status:
Pressure data:
Temperature data:
(padding bits:)

D31
D29
D15
D4

D30
D16
D5
D0

Figure 3 illustrates the sequence of signals set by both the host and the sensor for each command. Note that for the
DataRead command, the host has the option of responding to the second or third bytes of data with a NACK instead
of ACK. This terminates the data transmission after the pressure data, or after the pressure data and upper byte of
temperature, have been transmitted. See Figure 6 for the I2C timing details.

DLV Series Low Voltage Digital Pressure Sensors

Page 8

2-2

I2C Command Sequence


Depending on whether the Fast, Noise Reduced, Low-Power, or Sleep options have been selected, the command
sequence differs slightly. See Figure 3 for details of the three I2C commands.

Fast, Noise Reduced or Low-power Configuration

all sensors

The part enters Free Running mode (see table 1) after power-up: it performs an initial complete measurement, writes the calculated data to the output registers, sets the INT pin high, then goes to sleep.
After a delay determined by the update rate option, the part will wake up, perform measurements,
update the output registers, then go back to sleep. DataRead is the only command recognized in this
Free Running Mode. If the INT pin is ignored, the host processor can repeat the DataRead command
until the Status bits indicate an updated reading. Note: The INT pin is not available on the SIP version
packages (ExBS versions).

Sleep Configuration

e www.allsensors.com

The part enters Triggered mode (see table 1) after power-up, and waits for a command from the bus
master. If the StartAll command is received, the temperature, ADC zero, and pressure readings are all
measured, and correction calculations are performed. When valid data is written to the output registers,
the INT pin is set high, and the processing core goes back to sleep. The host processor then sends the
DataRead command to shift out the updated values. If the INT pin is not monitored, the host can poll
the output registers by repeating the DataRead command until the Status bits indicate that the values
have been updated (see Tables 2 and 3). The response time depends on configuration options (refer to
Table 1 and Performance Characteristics).

p 408 225 4314

f 408 225 2079

Depending on the application, pressure measurements may be performed by sending the StartPressure
command, which only measures the pressure value and uses previously measured temperature data in
calculating the compensated output value. This presents the result faster (in about 1/3 the delay time)
than the StartAll command. This can be a useful method to synchronize the sensor with the host controller as well as attaining the fastest overall response time without Special cycles occuring at unwanted
times. The system designer should determine the interval required for sending StartAll commands, necessary to refresh the temperature and zero point data, in order to maintain accurate output values.

I2C Exceptions

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

1. Sending a Start condition, then a Stop condition, without any transitions on the CLK line, creates
a communication error for the next communication, even if the next start condition is correct and the
clock pulse is applied. A second Start condition must be set, which clears the error and allows communication to proceed.
2. The Restart conditiona falling SDA edge during data transmission when the CLK clock line is still
high creates the same stall/deadlock. In the following data request, an additional Start condition must
be sent for correct communication.
3. A falling SDA edge is not allowed between the start condition and the first rising SCL edge. If using
an I2C address with the first bit 0, SDA must be held low from the start condition through the first bit.

All Sensors

DS-0336 Rev B

Page 9

2-2

SPI Interface
SPI Command Sequence
DLV sensors using the SPI interface option provide 3 signals for communication: SCLK, SS (Slave Select), and MISO.
This read-only signaling uses a hardware protocol to control the sensor, differing slightly with the speed/power option selected as described below:
Fast(F), Noise Reduced(N) and Low-Power(L) Configurations: After power-up, the part enters Free Running mode and begins its periodic conversion cycle, at the interval determined by the programmed
Power/Speed option. This is the simplest configuration. The only bus interaction with the host is the SPI
DataRead operations. Polling the sensor at a rate slower than the internal update rate will minimize bus
activity and ensure that new values are presented with each transfer. Note that the Status bits should still
be checked to verify updated data and the absence of error conditions.
Sleep(S) Configuration: As with the I2C option, the part enters Triggered mode after power-up, and waits
for a command from the bus master. To wake the part and start a measurement cycle, the SS pin must be
driven low by the host for at least 8usec, then driven high. This can be done by shifting a dummy byte of 8
bits from the sensor. This bus activity can be considered the SPI StartAll command, where the rising edge
of SS is the required input to start conversion. Updated conversion data is written to the output registers
after a period dependent on configuration options ( see Performance Characteristics). After this update of
the registers, the core goes to an inactive (sleep) state. The DataRead command simply consists of shifting
out 2, 3, or 4 bytes of data from the sensor. The host can check the Status bits of the output to verify that
new data has been provided. The part remains inactive following this read operation, and another StartAll
operation is needed to wake the part when the next conversion is to be performed.

SPI Bit Pattern


The sequence of bits and bus signals are shown in the following illustration (Figure 4). Refer to Figure 5 in the Interface Timing Diagram section for detailed timing data. As previously described, the incoming data may be terminated
by raising SS after 2, 3, or 4 bytes have been received as illustrated below.

Figure 4 - SPI Bit Pattern

DLV Series Low Voltage Digital Pressure Sensors

Page 10

2-2

Interface Timing Diagrams

Figure 5 - SPI Timing Diagram

tSCLK
tLOW

tSSCLK

tHIGH

SCLK
(HIZ)

(HIZ)

all sensors

MISO

tCLKD

tCLKD

SS
tCLKSS
S YMBOL

MIN

f SCLK
f SCLK

50
50
2.5
0.6
0.6
0
0.1
2

MAX

UNITS

800
200

kHz
kHz

0.1

us
us
us
us
us
us

f 408 225 2079

tSSCLK
tLOW
tHIGH
tCLKD
tCLKSS
tIDLE

TYP

e www.allsensors.com

P ARAMETER

S CLK clock frequency (4MHz clock)


S CLK clock frequency (1MHz clock)
S S drop to firs t clock edge
Minimum S CLK clock low width
Minimum S CLK clock high width
Clock edge to data trans ition
Ris e of S S relative to las t clock edge
Bus free time between ris e and fall of S S

tIDLE

tH STA

tHIGH

p 408 225 4314

Figure 6 - I2C Timing Diagram

tLOW

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

SCL
SDA
tSUSTA

tSUDAT

P ARAMETER

S CL clock frequency
S tart condition hold time relative to S CL edge
Minimum S CL clock low width
Minim um S CL clock high width

S tart condition s etup time relative to S CL edge


Data hold time on S DA relative to S CL edge
Data s etup time on S DA relative to S CL edge
S top condition s etup time on S CL
Bus free time between s top condition and s tart cond .

All Sensors

tH DAT

tSUSTP

S YMBOL

MIN

fSCL
tHSTA
tLOW
tHIGH
tSUSTA
tHDA T
tSUDA T
tSUSTP
tIDLE

100
0.1
0.6
0.6
0.1
0
0.1
0.1
2

TYP

tIDLE
MAX

UNITS

400

kHz
us
us
us
us
us
us
us
us

DS-0336 Rev B

Page 11

2-2

How to Order
Refer to Table 4 for configuring a standard base part number which includes the pressure range, package and temperature range. Table 5 shows the available configuring options. The option identifier is required to complete the
device part number. Refer to Table 6 for the available options.
Example P/N with options: DLV-005G-E1BD-C-NI3F

ORDERING INFORMATION

Table 4 - How to Configure a Base Part Number


SERIES
ID
DLV

PRESSURE RANGE
ID
005G
015G
015A
030G
030A
060G
060A

Base
ID
E

Description
0 to 5 PSI
0 to 15 PSI
0 to 15 PSIA
0 to 30 PSI
0 to 30 PSIA
0 to 60 PSI
0 to 60 PSIA

Example DLV - 005G

- E

ID
1
2

Port Orientation
Description
Dual Port Same Side
Dual Port Opposite Side

ID
B

PACKAGE
Lid Style
Description
Barbed

TEMPERATURE RANGE
ID
S
D

Lead Type
Description
SIP
DIP

ID
C
I

Description
Commercial
Industrial

- C

ORDERING
INFORMATION

Table 5 - How to Configure an Option Identifier


COATING
ID Description
N No Coating
P Parylene Coating

Example N

INTERFACE

SUPPLY VOLTAGE

ID Description
I I2C
S SPI

ID Description
3 3.3V
5 5.0V

SPEED/POWER
ID
F
N
L
S

Description
Fast
Noise reduced
Low Power
Sleep Mode

TABLE 6: Available E-Series Package Configurations


Port
Orientation

DualPort
SameSide

NonBarbedLid
LeadStyle

BarbedLid
LeadStyle

SIP

DIP

JLeadSMT

LowProfileDIP

N/A

N/A

N/A

N/A

SIP

E1BS

DualPort
OppositeSide

SinglePort
(Gage)

N/A

N/A

N/A

N/A

N/A

N/A

DIP

LowProfileDIP

N/A

N/A

N/A

N/A

N/A

N/A

E1BD

N/A

N/A

JLeadSMT

E2BS

E2BD

N/A

N/A

DLV Series Low Voltage Digital Pressure Sensors

Page 12

2-2

Package Drawings
E1BS Package

Pinout
1) Gnd
2) Vs
3) SDA
4) SCL

0.51
0.020

e www.allsensors.com

Port A

2.73
0.107

[9.65]
0.380 (nom)
0.25
0.010

all sensors

1.68
0.066

10.80
0.425

Port B

6.45
0.254

9.80
0.386

1.14
0.045

10.80
0.425

15.75
0.620

0.64
0.025

2.11
0.083

12.70
0.500

4.88
0.192

2.24
0.088

9.15
0.360

2.54
0.100

Pin 1 2 3 4

E2BS Package

f 408 225 2079

NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

Pinout

1.68
0.066

10.80
0.425

Port B

2.73
0.107

15.75
0.620
[9.65]
0.380 (nom)

9.80
0.386
0.25
0.010

1.14
0.045

10.80
0.425

Port A

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

2.12
0.084

2.11
0.083

12.70
0.500

2.24
0.088

9.15
0.360

0.64
0.025

p 408 225 4314

1) Gnd
2) Vs
3) SDA
4) SCL

0.51
0.020

2.54
0.100

Pin 1 2 3 4
NOTES
1)Dimensions are in inches [mm]
2)For suggested pad layout, see drawing: PAD-01

All Sensors

DS-0336 Rev B

Page 13

2-2

Package Drawings (Contd)


E1BD Package

Pinout

0.46
0.018

1) Gnd
2) Vs
3) SDA/MISO
4) SCL/SCLK
5) INT/SS
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

5.72
0.225

Pin 8 7 6 5

9.15
0.360
0.64
0.025

2.11
0.083

12.70
0.500

4.88
0.192

1.14
0.045

10.80
0.425

2.24
0.088

1.68
0.066

10.80
0.425

15.75
0.620

2.54
0.100

8.89
0.350
(min)

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

Port A

2.73
0.107

1.48
0.058

0.25
0.010

6.45
0.254

9.80
0.386

16
0.630

Port B

Pin 1 2 3 4

E2BD Package

Pinout

0.46
0.018

1) Gnd
2) Vs
3) SDA/MISO
4) SCL/SCLK
5) INT/SS
6) Do Not Connect
7) Do Not Connect
8) Do Not Connect

5.72
0.225

Pin 8 7 6 5

9.15
0.360

12.70
0.500

0.64
0.025

NOTES
1) Dimensions are in inches [mm]
2) For suggested pad layout, see drawing: PAD-03

1.68
0.066

10.80
0.425

15.75
0.620

Port B

2.73
0.107

0.25
0.010

1.48
0.058

9.80
0.386

16
0.630

Port A

8.89
0.350
(min)

1.14
0.045

10.80
0.425

2.24
0.088

2.12
0.084

2.11
0.083

2.54
0.100

Pin 1 2 3 4

DLV Series Low Voltage Digital Pressure Sensors

Page 14

2-2

0.035~0.039 inch
(Finish Size)

2.54
0.100
(typ.)

0.035~0.039 inch
(Finished Size)

2.54
0.100
(typ.)

Suggested Pad Layout

PAD-03

e www.allsensors.com

PAD-01

all sensors

16
0.630

Product Labeling

f 408 225 2079

Company
Part Number
Lot Number

p 408 225 4314

All Sensors
DLV-005GE1BD-C
NI3F
R14N25-01

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Example Device Label

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.

All Sensors

DS-0336 Rev B

Page 15

2-2

FPS SERIES PRESSURE SENSOR


Features
Pressure Ranges from 0.1 to 2 inH2O (25 to 500 Pa)
Pressure Sensor based on thermal micro-flow measurement
Calibrated and Temperature compensated
Analog Output and Digital SPI Interface
High Flow Impedance
Very low flow-through leakage
High immunity to dust and humidity
No loss in sensitivity using long tubing
RoHS and REACH compliant

all sensors

Applications
HVAC
Medical

Media
Air and other non-corrosive gasses

Burst Pressure5

FPSS025U

0.1 inH2O

0 - 25 Pa

0 - 0.25 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS050U

0.2 inH2O

0 - 50 Pa

0 - 0.50 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS100U

0.4 inH2O

0 - 100 Pa

0 - 1.00 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS250U

1.0 inH2O

0 - 250 Pa

0 - 2.50 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS500U

2.0 inH2O

0 - 500 Pa

0 - 5.00 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS025B

0.1 inH2O

0 - 25 Pa

0 - 0.25 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS050B

0.2 inH2O

0 - 50 Pa

0 - 0.50 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS100B

0.4 inH2O

0 - 100 Pa

0 - 1.00 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS250B

1.0 inH2O

0 - 250 Pa

0 - 2.50 mbar

30 psi (2 bar)

30 psi (2 bar)

FPSS500B

2.0 inH2O

0 - 500 Pa

0 - 5.00 mbar

30 psi (2 bar)

30 psi (2 bar)

Gas Correction Factors10 (Page 7)


Gas Type
Dry Air
Oxygen (O2)
Nitrogen (N2)
Argon (Ar)
Carbon dioxide (CO2)

f 408 225 2079

Proof Pressure5

p 408 225 4314

Operating Pressure

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Device

e www.allsensors.com

Pressure Sensor Characteristics

Electrical Connection

Correction Factor
1.00
1.07
0.97
0.98
0.56

All Sensors

Pin
1, 10
2
3
4, 5
6
7
8
9

Connection
Do Not Connect
Vs
GND
Vout
SCLK
MOSI
MISO
/CS

Note: Pins 1 and 10 are internally connected.

DS-0329 Rev B

Page 1

2-3

Specifications
Pressure Sensor Maximum Ratings

Environmental Specifications

Supply Voltage (VS)


FPS 3V

2.70 to 3.30 Vdc

FPS 5V

4.75 to 5.25 Vdc

Output Current

1 mA

Lead Specifications
Average preheating temperature gradient
Soak time
Time above 217C
Time above 230C
Time above 250C
Peak Temperature
Cooling Temperature gradient

2.5 C/s
Approx. 3 min
50 s
40 s
15 s
260C
-3.5 C/s

Temperature Ranges
Compensated
Operating
Storage

0C to 70C
-20C to 80 C
-40C to 80 C

Humidity Limits

Vibration1
Mechanical Shock2

97% RH
(non condensing)
20 g
500 g

Specification Notes
note 1: Sweep 20 to 2000 Hz, 8 min, 4 cycles per axis, MIL-STD-883, Method
2007.
note 2: 5 Shocks, 3 axes, MIL-STD-883E, Method 2002.4.

Performance Characteristics4 for: FPSS025x, FPSS050x 5V Device

(Vs = 5.0 VDC , TA= 20 C , PAbs = 1 bara, calibrated in air, output signals analog and digital are non-ratiometric to Vs)

Common Characteristics

Min

Typ

Max

(1% of reading + 0.5 % FSS)

(1.5% of reading + 1.5 % FSS)

(3.5% of reading +1.5 %FSS)

0.03

%FSS

less than noise

0.0002

0.0004

inH2O/year

Current Consumption (no load)

mA

Response Time (t63)

ms

Power-On Time

25

ms

Characteristics

Min

Typ

Max

Units

Zero Pressure Offset

0.49

0.50

0.51

Full Scale Span

3.97

4.00

4.03

4.50

Offset @ 5 to 55C

20

mV

Offset @ 0 to 70C

40

mV

Span @ 5 to 55C

1.25

%FSS

Span @ 0 to 70C

1.75

2.75

%FSS

Non-Linearity9
Total Accuracy 5 to 55C
3

0 to 70C
Noise Level(RMS)
Offset Warm-Up Shift
Offset Long Term Stability
6

Units

Analog Output (Unidirectional Devices)

Full Scale Output


Thermal Effects
Thermal Effects

FPS Series Pressure Sensor

Page 2

2-3

Performance Characteristics4 (Contd)

Analog Output (Bidirectional Devices)

Min

Typ

Max

Units

Zero Pressure Offset

2.49

2.50

2.51

Full Scale Span

3.97

4.00

4.03

Output @ Max. Specified Pressure

4.50

Output @ Min. Specified Pressure

0.50

Offset @ 5 to 55C

15

mV

Offset @ 0 to 70C

30

mV

Span @ 5 to 55C

1.25

%FSS

Span @ 0 to 70C

1.75

2.75

%FSS

Min

Typ

Max

Units

Scale Factor (Digital Output)7 0.1 inH2O / 0.1 inH2O

300

counts/0.001 inH2O

0.2 inH2O / 0.2 inH2O

150

counts/0.001 inH2O

Zero Pressure Offset Tolerance

-0.2

+0.2

%FSS

Full Scale Span Tolerance

-0.75

+0.75

%FSS

Offset @ 5 to 55C

60

counts

Offset @ 0 to 70C

120

counts

Span @ 5 to 55C

1.75

%FSS

Span @ 0 to 70C

1.75

2.75

%FSS

Thermal Effects
Thermal Effects

Performance Characteristics4 for: FPSS100x, FPSS250x, FPSS500x 5V Device

(Vs = 5.0 VDC , TA= 20 C , PAbs = 1 bara, calibrated in air, output signals analog and digital are non-ratiometric to Vs)

Common Characteristics

Min

Typ

Max

(1% of reading + 0.5 % FSS)

(1.5% of reading + 1.5 % FSS)

(3.5% of reading +1.5 %FSS)

0.03

%FSS

less than noise

0.1

%FSS/year

Current Consumption (no load)

mA

Response Time (t63)

ms

Power-On Time

25

ms

Non-Linearity

Total Accuracy @ 5 to 55C


3

@ 0 to 70C
Noise Level(RMS)
Offset Warm-Up Shift
Offset Long Term Stability
6

All Sensors

e www.allsensors.com

Characteristics

p 408 225 4314

Digital Output

f 408 225 2079

Thermal Effects

Units

DS-0329 Rev B

Page 3

2-3

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Thermal Effects

all sensors

Characteristics

Performance Characteristics4 (Contd)

Analog Output (Unidirectional Devices)

Characteristics

Min

Typ

Max

Units

Zero Pressure Offset

0.49

0.50

0.51

Full Scale Span

3.97

4.00

4.03

4.50

Offset @ 5 to 55C

10

mV

Offset @ 0 to 70C

12

mV

Span @ 5 to 55C

1.75

%FSS

Span @ 0 to 70C

2.75

%FSS

Characteristics

Min

Typ

Max

Units

Zero Pressure Offset

2.49

2.50

2.51

Full Scale Span

3.97

4.00

4.03

Output @ Max. Specified Pressure

4.50

Output @ Min. Specified Pressure

0.50

Offset @ 5 to 55C

10

mV

Offset @ 0 to 70C

12

mV

Span @ 5 to 55C

1.75

%FSS

Span @ 0 to 70C

2.75

%FSS

Min

Typ

Max

Units

Scale Factor (Digital Output) 0.4 inH2O / 0.4 inH2O

75

counts/0.001 inH2O

1.0 inH2O / 1.0 inH2O

30

counts/0.001 inH2O

2.0 inH2O / 2.0 inH2O

15

counts/0.001 inH2O

Zero Pressure Offset Tolerance

-0.1

+0.1

%FSS

Full Scale Span Tolerance

-0.75

+0.75

%FSS

Offset @ 5 to 55C

30

counts

Offset @ 0 to 70C

60

counts

Span @ 5 to 55C

1.75

%FSS

Span @ 0 to 70C

2.75

%FSS

Full Scale Output


Thermal Effects
Thermal Effects

Analog Output (Bidirectional Devices)

Thermal Effects
Thermal Effects

Digital Output

Characteristics
7

Thermal Effects
Thermal Effects

FPS Series Pressure Sensor

Page 4

2-3

Performance Characteristics4 for: FPSS025x, FPSS050x 3V Device

(Vs = 3.0 VDC , TA= 20 C , PAbs = 1 bara, calibrated in air, output signals analog and digital are non-ratiometric to Vs)

@ 0 to 70C
Noise Level(RMS)

Typ

Max

Units

(1% of reading + 0.5 % FSS)

(1.5% of reading + 1.5 % FSS)

(3.5% of reading +1.5 %FSS)

0.03

%FSS

Offset Warm-Up Shift

less than noise

Offset Long Term Stability6

0.0002

0.0004

inH2O/year

Current Consumption (no load)8

14

16

mA

Response Time (t63)

ms

Power-On Time

25

ms

Characteristics

Min

Typ

Max

Units

Zero Pressure Offset

0.29

0.30

0.31

Full Scale Span

2.37

2.40

2.43

2.70

Offset @ 5 to 55C

20

mV

Offset @ 0 to 70C

40

mV

Span @ 5 to 55C

1.25

%FSS

Span @ 0 to 70C

1.75

2.75

%FSS

Characteristics

Min

Typ

Max

Units

Zero Pressure Offset

1.49

1.50

1.51

Full Scale Span

2.37

2.40

2.43

Output @ Max. Specified Pressure

2.70

Output @ Min. Specified Pressure

0.30

Offset @ 5 to 55C

15

mV

Offset @ 0 to 70C

30

mV

Span @ 5 to 55C

1.25

%FSS

Span @ 0 to 70C

1.75

2.75

%FSS

Thermal Effects
Thermal Effects

p 408 225 4314

Full Scale Output

f 408 225 2079

Analog Output (Unidirectional Devices)

Analog Output (Bidirectional Devices)

Thermal Effects
Thermal Effects

All Sensors

DS-0329 Rev B

Page 5

all sensors

Total Accuracy @ 5 to 55C


3

Min

e www.allsensors.com

Non-Linearity

2-3

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Common Characteristics

Performance Characteristics4 (Contd)

Digital Output

Characteristics

Min

Typ

Max

Scale Factor (Digital Output) 0.1 inH2O / 0.1 inH2O

300

counts/0.001 inH2O

0.2 inH2O / 0.2 inH2O

150

counts/0.001 inH2O

Zero Pressure Offset Tolerance

-0.2

+0.2

%FSS

Full Scale Span Tolerance

-0.75

+0.75

%FSS

Offset @ 5 to 55C

60

counts

Offset @ 0 to 70C

120

counts

Span @ 5 to 55C

1.75

%FSS

Span @ 0 to 70C

1.75

2.75

%FSS

Thermal Effects
Thermal Effects

Units

Performance Characteristics4 for: FPSS100x, FPSS250x, FPSS500x 3V Device

(Vs = 3.0 VDC , TA= 20 C , PAbs = 1 bara, calibrated in air, output signals analog and digital are non-ratiometric to Vs)

Common Characteristics

Min

Typ

Max

(1% of reading + 0.5 % FSS)

(1.5% of reading + 1.5 % FSS)

(3.5% of reading +1.5 %FSS)

0.03

%FSS

less than noise

0.1

%FSS/year

Current Consumption (no load)

14

16

mA

Response Time (t63)

ms

Power-On Time

25

ms

Characteristics

Min

Typ

Max

Units

Zero Pressure Offset

0.29

0.30

0.31

Full Scale Span

2.37

2.40

2.43

Non-Linearity

Total Accuracy 5 to 55C


3

0 to 70C
Noise Level(RMS)
Offset Warm-Up Shift
Offset Long Term Stability
6

Units

Analog Output (Unidirectional Devices)

Full Scale Output


Thermal Effects
Thermal Effects

2.70

Offset @ 5 to 55C

10

mV

Offset @ 0 to 70C

12

mV

Span @ 5 to 55C

1.75

%FSS

Span @ 0 to 70C

2.75

%FSS

FPS Series Pressure Sensor

Page 6

2-3

Performance Characteristics4 (Contd)

Analog Output (Bidirectional Devices)

Min

Typ

Max

Units

Zero Pressure Offset

1.49

1.50

1.51

Full Scale Span

2.37

2.40

2.43

Output @ Max. Specified Pressure

2.70

Output @ Min. Specified Pressure

0.30

Offset @ 5 to 55C

10

mV

Offset @ 0 to 70C

12

mV

Span @ 5 to 55C

1.75

%FSS

Span @ 0 to 70C

2.75

%FSS

Min

Typ

Max

Units

Scale Factor (Digital Output) 0.4 inH2O / 0.4 inH2O

75

counts/0.001 inH2O

1.0 inH2O / 1.0 inH2O

30

counts/0.001 inH2O

2.0 inH2O / 2.0 inH2O

15

counts/0.001 inH2O

Zero Pressure Offset Tolerance

-0.1

+0.1

%FSS

Full Scale Span Tolerance

-0.75

+0.75

%FSS

Offset @ 5 to 55C

30

counts

Offset @ 0 to 70C

60

counts

Span @ 5 to 55C

1.75

%FSS

Span @ 0 to 70C

2.75

%FSS

Thermal Effects
Thermal Effects

all sensors

Characteristics

Thermal Effects
Thermal Effects

Specification Notes (Contd)


note 3: Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis and temperature effects.
note 4: The sensor is calibrated with a common mode pressure of 1 bar absolute. Due to the mass flow based measuring principle, variations in absolute common mode pressure need to be compensated according to the following formula:

Peff
Psensor
Pabs

a 16035 Vineyard Blvd. Morgan Hill, CA 95037


Peff = Psensor x 14.5 psia
Pabs

f 408 225 2079

p 408 225 4314

Characteristics

e www.allsensors.com

Digital Output

= True differential pressure


= Differential pressure as indicated by output voltage
= Current absolute common mode pressure

5: The max. common mode pressure is 30 PSI


6: Figure based on accelerated lifetime test corresponding to 1 year of life.
Note 7: The digital output signal is a signed, twos complement integer. Negative pressures will result in a negative output.
Note 8: Please contact All Sensors Corporation for low power options.
Note 9: Non-linearity refers to a terminal based FSL (Fitting Straight Line) going through the actual zero pressure reading.
Note 10: For example with a FPSS500... sensor measuring CO2 gas, at full-scale output the actual pressure will be 2.00 inH2O x 0.56 = 1.12 inH2O.
note
note

Pe = Psensor x gas correction factor

Pe
Psensor

= True dierential pressure


= Dierential pressure as indicated by output voltage

Note 11: For correct operation of FPS 3V devices, the device driving the SPI bus must have a minimum drive capability of 2 mA.

All Sensors

DS-0329 Rev B

Page 7

2-3

SPI - SERIAL PERIPHERAL INTERFACE


Note: It is important to adhere to the communication protocol in order to avoid damage to the Sensor.

Introduction

Data read

The FPS serial interface is a high-speed data input


and output communication port that is asynchronous
to the internal conversion cycle. The serial interface
operates in 3-wire SPI mode. In this setup, the MOSI
and MISO pins are tied together, forming a bidirectional data line to the master microcontroller. The
remaining serial interface connections consist of chip
select (/CS) and serial clock (SCLK).

When powered on, the sensor begins to continuously measure pressure. To initiate data transfer from
the sensor, the following three unique bytes must be
written sequentially, MSB first, to the MOSI pin (see
Fig. 1):
Step Hexadecimal
Binary
Description
1
0x2D
B00101101 Poll current pressure measurement
2
0x14
B00010100 Send result to data register
3
0x98
B10011000 Read data register

Care should be taken to ensure that the sensor is


properly connected to the master microcontroller.
Refer to the manufacturer's datasheet for more information regarding physical connections.

The entire 16 bit content of the FPS register is then


read out on the MISO pin, MSB first, by applying 16
successive clock pulses to SCLK with /CS asserted
low. Note that the value of the FPS is held at zero
for internal signal processing purposes. This is
below the noise threshold of the sensor and thus its
fixed value does not affect sensor performance and
accuracy.

Signal control
The serial interface is enabled by asserting /CS low.
The serial input clock, SCLK, is gated internally to
begin accepting the input data at MOSI, or sending
the output data on MISO. When /CS rises, the data
clocked into MOSI is loaded into an internal register.

From the digital sensor output the actual pressure


value can be calculated as follows:

Note: If SPI communication is not required (i.e. only


analog output is being used) pins 6 to 8 must be
connected to ground and pin 9 to Vs. Failure to do so
may result in damage to the sensor.

Pressure [inH2O] = digital output [counts]


scale factor counts
inH2O

So for a 1.0 inH2O sensor (FPSS250B...) with a


scale factor of 120 a digital output of 30,000 counts
(7530h) calculates to a positive pressure of 1.0
inH2O. Similarly, a digital output of -30,000 counts
(8AD0h) calculates to a negative pressure of -1.0
inH2O.

Fig. 1 : Data Transfer

Step 1

Step 2

/CS
SCLK

(CPOL=0)
(CPAH=0)

MOSI

MISO
Step 3

Data from sensor

/CS
SCLK

(CPOL=0)
(CPAH=0)

MOSI

0
MSB

MISO

15

14

13

12

11

10

FPS Series Pressure Sensor

Page 8

2-3

Serial Interface Specification


Typ.

Max.

Units
MHZ

Internal Oscillator Clock Frequency

fICLK

OSC(4:0)=00000

3.3

4.15

5.3

External Clock Frequency

fECLK

VCKSEL=0 Min.

0.2

MHZ

40

60

%tECLK
%tECLK

fECLKIN LO

tECLK=1/fECLK

External Master Clock Input High Time

fECLKIN HI

tECLK=1/fECLK

40

60

SCLK Setup to Falling Edge /CS

tSC

30

ns

/CS Falling Edge to SCLK Rising Edge Setup Time

tCSS

30

ns

/CS Idle Time

tCSI

fCLK= 4 MHZ

1.5

SCLK Falling Edge to Data Valid Delay

tDO CLOAD=15 pF

Data Valid to SCLK Rising Edge Setup Time

tDS

Data Valid to SCLK Rising Edge Hold Time

tDH

SCLK High Pulse Width

tCH

80

ns

30

ns

30

ns

100

ns

SCLK Low Pulse Width

tCI

100

ns

/CS Rising Edge to SCLK Rising Edge Hold Time

tCSH

30

ns

/CS Falling Edge to Output Enable

tDV

CLOAD=15 pF

25

ns

/CS Rising Edge to Output Disable

tTR

CLOAD=15 pF

25

ns

FPS (5 V Supply)
Maximum Output Load Capacities
CLOAD

Input Voltage, Logic HIGH
VIH
Input Voltage, Logic LOW
VIL
Output Voltage, Logic HIGH
VOH

Output Voltage, Logic LOW
VOL

RLOAD= ,

200

pF

Phase Margin > 55

-
-
RLOAD= ,
RLOAD= 2 k ,
RLOAD= ,
RLOAD= 2 k ,

0.8 x Vs
-
Vs-0.1
Vs-0.15
-
-

-
-
-
-
-
-

-
0.2 x Vs
-
-
0.5
0.2

V
V
V
V
V
V

15
-
-
-
-

-
-
0.35 x Vs
-
0.4

pF
V
V
V
V

all sensors

Max.

External Master Clock Input Low Time

e www.allsensors.com

MHZ

f 408 225 2079

Symbol Conditions Min.

p 408 225 4314

Parameter

Maximum Output Load Capacities


Input Voltage, Logic HIGH
Input Voltage, Logic LOW
Output Voltage, Logic HIGH
Output Voltage, Logic LOW

CLOAD
VIH
VIL
VOH
VOL

RLOAD= 1 k ,
-
-
0.65 x Vs
-
-
IO= -20 A
Vs-0.4
IO=20 A
-

Fig. 2 : Timing Diagram


tCSI

/CS
tSC
SCLK

tDS

tCSS

tCL

tCSH

tCH

tDH

MOSI
tDV

tDO

tTR

MISO

All Sensors

DS-0329 Rev B

Page 9

2-3

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

FPS (3 V Supply)11

Package Drawings

FA01 Package
17.70
12.70
0.15

5.60
0.2
0.25

High pressure port

10 9 8 7 6

3.0
13.85 15.22

18.03

17.53
10.70
0.15

5.0

2.20

6.26
1 2 3 4 5

1.43
5.08

2.54
3.10
0.2

0.51
1.27

1.60
0.2

5.60

dimensions in mm
2.50

FA02 Package

17.70
12.70
0.15

5.60
0.2

High pressure port

10 9 8 7 6
3.0

0.25
14.97

18.03

17.53
10.70
0.15

5.0

2.20

6.26
1 2 3 4 5

7.85
8.95
0.5
15.65
16.05

10.16
2.54
0.46

3.10
0.2

1.60
0.2
5.60

dimensions in mm
2.50

FPS Series Pressure Sensor

Page 10

2-3

How To Order

Series
Options

FPS

Pressure Range

Calibration

Housing

S025

0.1 inH2O
(25 Pa)

Differential
(Bidirectional)

S050

0.2 inH2O
(50 Pa)

Gage
(Unidirectional)

S100

0.4 inH2O
(100 Pa)

S250

FA01
SMT, 2 ports
same side
FA02
DIP, 2 ports

Output
3

non-ratiometric,
3 V supply

non-ratiometric,
5 V supply

Grade
S

High

1 inH2O

S500

all sensors

(250 Pa)
2 inH2O
(500 Pa)

S250

e www.allsensors.com

FPS

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

p 408 225 4314

f 408 225 2079

Example:

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

All Sensors

DS-0329 Rev B

Page 11

2-3

DIGITAL OUTPUT PRESS U R E

SENSORS

Enhanced Digital Output Sensors

Features

all sensors

5 H2O to 100psi Pressure Ranges


All Combined Errors Over Temperature Less Than 0.1%, Typical
Wide -20 to 85C Compensated Temperature Range
Electrically Compatible to All Sensors GA142 Series
Enhanced Dual Serial Interface Mode

Applications

Medical Instrumentation
Environmental Controls
HVAC
Meteorology

e www.allsensors.com

General Description
The Digital Output pressure sensors are based upon a proprietary surface mapping technology to produce a fully digital
output that virtually eliminates all repeatable errors over temperature and pressure. This series provides a 12 bit digital
serial output (14 bit in High Resolution Mode) with superior offset, span and linearity characteristics. The output is SPI and
MICROWIRE/PLUS compatible as well as fully compatible with the All Sensors GA142 Series sensors.

f 408 225 2079

In addition to synchronous communications, the Digital Output pressure sensors incorporates a bi-directional, TTL level,
asynchronous serial interfaces mode (hardware selectable 9,600 or 19,200 baud). This mode includes a command set that
allows the host to interrogate the sensor for model information, pressure range, serial number, pressure units and
conversion factor. The command set also allows the host to select a high resolution output mode, make minor adjustments
to offset and has an addressable feature that alows multiple sensors to be tied to the same interface buss.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. All signals
are 5V TTL/CMOS compatible.

Physical Dimensions
0.25
(6.4)

Pin Descriptions

Pin Size
0.010 x 0.020
(0.25 x 0.50)

Pin 1 2 3 4 5 6

0.174 to 0.190
(4.4 to 4.8)

0.21
(5.3)

A
1.08
(27.4)
0.63
(16.0)

0.48
(12.2)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

0.80
(20.3)

Data/SI

Data output for synchronous


mode. Serial in for asynchronous mode.

Clock/SO

Clock output for synchronous


mode. Serial out for asynchronous mode.

Ready/Mode Ready output for synchronous


mode. Selects asynchronous
mode when held low during
reset.

Convert/BR

Convert input for synchronous


mode. Selects one of two
baud rates for asynchronous
mode (low=9,600,
high=19,200).

Ground

Ground for power and signals

0.414
(10.5)

0.85
(21.6)

DS-0012 Rev A

Description
+5V power supply input

1.10
(27.9)

All Sensors

Pin Label
1 Vcc

0.10 Typical
(2.54)

0 1
2-4

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Absolute Maximum Ratings

Environmental Specifications

Supply Voltage (Vcc)

7Vdc

Voltage on Any Pin with Respect to Gnd

Operating Voltage

-0.6 to Vcc+0.6V

Common-mode pressure

Compensated Temperature

50 psig

Lead Temperature (soldering 2-4 sec.)

+4.75Vdc to +5.25Vdc

250C

-20 C to +85 C

Operating Temperature

-25 to +90 C

Storage Temperature

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


(4)

Proof Pressure

Burst Pressure

200 inH2O

300 inH2O

inH2O

10

200 inH2O

300 inH2O

-1 to 1

PSI

200 inH2O

300 inH2O

-5 to 5

PSI

10 PSI

30 PSI

15 PSI-D-DO

-15 to 15

PSI

15

60 PSI

120 PSI

15 PSI-A-DO

0 to 15

PSIA

15

60 PSI

120 PSI

-30 to 30

PSI

30

90 PSI

150 PSI

0 to 30

PSIA

30

90 PSI

150 PSI

-100 to 100

PSI

100

200 PSI

250 PSI

0 to 100

PSIA

100

200 PSI

250 PSI

Operating Pressure

Units

-5 to 5

inH2O

-10 to 10

1 PSI-D-DO
5 PSI-D-DO

Part Number
5 INCH-D-DO
10 INCH-D-DO

30 PSI-D-DO
30 PSI-A-DO
100 PSI-D-DO
100 PSI-A-DO

FSO

(2)

Digital Span

General Performance Characteristics (All Models)


Parameter

(1)

Minimum

Nominal

Maximum

Units

12

--

--

Bit

Conversion Speed

--

16

mS

Supply Current

--

12

mA

Minimum

Nominal

Maximum

Units

--

0.25

0.5

%FSO

Long Term Drift (one year)

--

--

0.5

%FSO

Offset Position Sensitivity (1g)

--

--

0.05

%FSO

--

--

0.25

%FSO

Resolution

Performance Characteristics for 5 INCH-D-DO


Parameter

(1)

Overall Accuracy

(5)

Offset Warm-up Shift

(3)

Performance Characteristics for 10 INCH-D-DO and 1 PSI-D-DO


Parameter

(1)

Minimum

Nominal

Maximum

Units

--

0.25

0.5

%FSO

Long Term Drift (one year)

--

--

0.5

%FSO

Offset Position Sensitivity (1g)

--

--

0.03

%FSO

--

--

0.25

%FSO

Overall Accuracy

(5)

Offset Warm-up Shift

0 2

(3)

Digital Output Pressure Sensors


2-4

Performance Characteristics for 5 PSI-D-DO through 100 PSI-x-DO


Overall Accuracy

Minimum

Nominal

Maximum

Units

--

0.10

0.25

%FSO

--

--

0.25

%FSO

(5)

Long Term Drift (one year)

all sensors

Specification Notes
NOTE 1:
UNLESS OTHERWISE SPECIFIED, ALL PARAMETERS ARE MEASURED AT 5.0 VOLT SUPPLY, POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2: THE DIGITAL OUTPUT IS A 16 BIT SIGNED BINARY OUTPUT IN A TWOS COMPLIMENT FORMAT. T HE APPLIED PRESSURE IS COMPUTED USING THE PRESSURE
CONVERSION TABLE (BELOW). THE MODE COLUMN IDENTIFIES THE RESOLUTION OPERATING MODE OF THE DEVICE (A = STANDARD RESOLUTION, B =
HIGH RESOLUTION). FSO AND UNITS ARE SHOWN FOR EACH MODEL.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: DIGITAL SPAN IS DEPENDENT ON THE RESOLUTION OPERATING MODE. REFER TO THE DIGITAL SPAN TABLE (BELOW) TO IDENTIFY THE DIGITAL SPAN OF THE
SPECIFIC MODEL. IN THE EVENT OF AN OVER-PRESSURE OR UNDER-PRESSURE CONDITION, THE DIGITAL OUTPUT WILL ONE COUNT HIGHER OR ONE COUNT
LOWER (RESPECTIVELY) TO THE LISTED DIGITAL SPAN TO INDICATE THE CONDITION.
NOTE 5: O VERALL ACCURACY INCLUDES THE COMBINED EFFECTS OF OFFSET AND SPAN SHIFTS OVER TEMPERATURE, LINEARITY, HYSTERESIS, AND OFFSET AND SPAN
CALIBRATION .

Synchronous Timing Diagram (Note: Asynchronous mode timing is per RS-232. To use RS-232 requires the Maxim MA232
interface circuit for proper voltage level compatibility.)

READY [Output]
t1

t10
t2

t2

e www.allsensors.com

Parameter (1)

f 408 225 2079

CONVERT [Input]
t3
t4

t8

t9

t5
CLOCK [Output]
t6

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

t7
DATA [Output]
Bit
15
MSB

Ref
t1
t2
t3
t4
t5

Parameter
Conversion Time
Ready to Convert
Convert to Clock
Clock Period
Clock High Time

Min
-0
24
---

Typ
8
-32
24
12

Bit
14

Max
16
-39
---

Bit
13

Bit
12

Bit
11

Bit
10

Units
msec
usec
usec
usec
usec

Bit
9

Bit
8

Ref
t6
t7
t8
t9
t10

Bit
7

Bit
6

Bit
5

Parameter
Data Setup Time
Data Hold Time
Interbyte Delay
Clock to Ready
Data Transmission

Bit
4

Bit
3

Min
------

Bit
2

Typ
3
3
70
14
476

Bit
1

Bit
0
LSB

Max
------

Units
usec
usec
usec
usec
usec

Typical Configurations
Synchronous Communications

Asynchronous Communications

Typical synchronous communications

Typical asynchronous communications

configuration (compatible with All

configuration. The Mode pin is

Sensors GA142 Series Digital Output

interrogated at power up and if tied

Sensors).

low, will cause the sensor to enter

Sensor
Host
System

(1)

Clock/SO
Data/SI
Convert/BR
Ready/Mode

asynchronous communications mode.

Host
System

Sensor
Clock/SO
Data/SI
Convert/BR
Ready/Mode

All Sensors

This mode supports multiple sensors by


addressable commands. The Convert/
BR pin then serves to select one of two
available baud rates.

Sensor

(n)

Clock/SO
Data/SI
Convert/BR
Ready/Mode

DS-0012 Rev A
2-4

Command Summary Table:


Command
Description

Response

RA<cr>

Read Accuracy String

RA=[Accuracy String]<cr>

RC<cr>

Read Captured Pressure

RC=[hhhh]<sp>[eeee]<cr>

RH<cr>

Read High Resolution Pressure

RH=[hhhh]<sp>[eeee]<cr>

RL<cr>

Read Low Resolution Pressure

RL[llll]<sp>[eeee]<cr>

RM<cr>

Read Model

RM=[Model String]<cr>

RR<cr>

Read Pressure Range

RR=[pressure Range String]<cr>

RS<cr>

Read Serial Number

RS=[S/N String]<cr>

RT<cr>

Read Temperature

RT=[Temperature Range String]<cr>

U[S/N String][Command]<cr>

Unique Command

For Matching S/N

U[S/N String],sp>[Response String]

For Non-matching S/N {null}


WC<cr>

Capture Pressure

{null}

Notations:
<> indicates a single ascii character
[] indicates an ascii string
{} text within the braces describes the response (this is essentially a comment)

16-Mar-03

text within quotes represents a literal ascii text string

0 4

Definitions:
Term

Name

Description

<cr>

Carriage Return

ascii Carrage Return. This is a command/response delimiter

<sp>

Space

ascii Space Character

[Accuracy String]

Accuracy String

Part accuracy string. Given in % full scale output.


Example: 0.250 %FSO
Notes:
1.) There is a space between the numeric accuracy 0.250
and units %FSO.
2.) FSO stands for Full Scale Output (full scale output is
determined by the Pressure Range String.)

[hhhh]

High Resolution Output

This is a four character ascii string representing a


hexidecimal value.
Example: 3F7C
Represents an output count of 16,252
Note: the output is forced to 8000 upon an error.
except error bit 8, see error bit codes.

[llll]

Low Resolution Output

This is a four character ascii string representing a


hexidecimal value.
Example: 1D58
Represents an output count of 7,512
Note: the output is forced to 8000 upon an error.
except error bit 8, see error bit codes.

[Model String]

Model String

Part Model as given in the data sheet (also order number.)


The general model syntax is
[Full Scale Pressure]<sp>[Pressure Units]-[Pressure Model]-DO
Example: 100 PSI-D-DO
Where:
Full Scale Pressure=100
Pressure Units=PSI (inH2O, mbar or mmHg available)
DO represents Digital Output
Notes:
1.) Exception to this syntax is the Barometer.
2.) Custom models may be different.

Digital Output Pressure Sensors


2-4

Description

Pressure Range String

This is the compensated pressure range of the part.


Syntax: [low limit]<sp>to<sp>[high limit]<sp>[units}[mode]
Esample: 20 to 32 mmHgA
Where:
Low limit = 20
High limit = 32
Units = mmHg
Mode = A (absolute pressure) (D differential and G gage
pressure also available.)

[Response String]

A Fully Formed Response String

Example: RL=1E43<sp>0000<cr>

[S/N String]

Serial Number String

YMDD-NN-BSPP (12 character String)


Where:
Y : Year (0~9)
M : Month (A~M, excluding I)
DD: Day of Month
NN: Lot (lot sequence for a given day)
B : Lot Batch# (A~Z)
S : Test Oven Slot# (1~5)
P : Position on Slot (1~15)
Example: 3D23-03-A103

all sensors

Name

[Pressure Range String]

Month Codes

e www.allsensors.com

January : A
February : B
March
:C
April
:D
May
:E
June
:F
July
:G
August : H
September : J
October : K
November : L
December : M

[Temperature Range String]

Temperature Range String

This is the compensated temperature range of the part.


Syntax: [low limit]<sp>[high limit]<sp>C
Example: -20 to 85 C
-40 to 125 C and custom ranges also available.

[eeee]

Error Codes

The error codes are bits packed within a double byte.


The four character string is an ascii hex expression.
The error code bits are:
Bit 0 : Part not factory compensated
Bit 1 : Tdex Overflow
Bit 2 : Tdex Over-range
Bit 3 : Pdex Overflow
Bit 4 : Pdex Over-range
Bit 5 : PWL Overflow
Bit 6 : Scale Overflow
Bit 7 : High Resolution Overflow
Bit 8 : Pressure Output Limited to Specific Value
Bits 9 through 15 : Reserved

f 408 225 2079

April 23, 2003


3rd lot of the day
Batch A, Slot 1, Position 03
This allows traceability to original test data

Example: 0100
Represents erro bit 8 set and the Pressure Output Limited
Notes:
Bit 0 : This should not appear if the part has been calibrated
Bits 1 thru 7 : indicate computational error when compensated
Bit 8: indicates that the pressure applied to the part exceeds the
range of the part and is limit to either the high or low limit
{null}

Null Response

No response from the part. In the event of a serial number


mismatch the part will not respond (to avoid buss contention.)

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.
MICROWIRE/PLUS

IS A REGISTERED TRADEMARK OF

All Sensors

NATIONAL SEMICONDUCTOR.

DS-0012 Rev A
2-4

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Definitions:
Term

DIGITAL OUTPUT PRESSURE SENSORS


Enhanced Digital Output Sensors MILITARY GRADE

Features

all sensors

5 H2O to 100psi Pressure Ranges


All Combined Errors Over Temperature Less Than 0.1%, Typical
Wide -40 to 125C Compensated Temperature Range
Electrically Compatible to All Sensors GA142 Series
Enhanced Dual Serial Interface Mode

Applications
Medical Instrumentation
Environmental Controls
HVAC
Meteorology

e www.allsensors.com

General Description
The Digital Output pressure sensors are based upon a proprietary surface mapping technology to produce a fully digital
output that virtually eliminates all repeatable errors over temperature and pressure. This series provides a 12 bit digital
serial output (14 bit in High Resolution Mode) with superior offset, span and linearity characteristics. The output is SPI and
MICROWIRE/PLUS compatible as well as fully compatible with the All Sensors GA142 Series sensors.

asynchronous serial interfaces mode (hardware selectable 9,600 or 19,200 baud). This mode includes a command set that
allows the host to interrogate the sensor for model information, pressure range, serial number, pressure units and
conversion factor. The command set also allows the host to select a high resolution output mode, make minor adjustments
to offset and has an addressable feature that alows multiple sensors to be tied to the same interface buss.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. All signals
are 5V TTL/CMOS compatible.

Physical Dimensions
0.25
(6.4)

Pin Descriptions

Pin Size
0.010 x 0.020
(0.25 x 0.50)

Pin 1 2 3 4 5 6

0.174 to 0.190
(4.4 to 4.8)

0.21
(5.3)

A
1.08
(27.4)
0.63
(16.0)

0.48
(12.2)

Pin Label
1 Vcc

0.10 Typical
(2.54)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

Data/SI

Data output for synchronous


mode. Serial in for asynchronous mode.

Clock/SO

Clock output for synchronous


mode. Serial out for asynchronous mode.

Ready/Mode Ready output for synchronous


mode. Selects asynchronous
mode when held low during
reset.

Convert/BR

Convert input for synchronous


mode. Selects one of two
baud rates for asynchronous
mode (low=9,600,
high=19,200).

Ground

Ground for power and signals

0.85
(21.6)
1.10
(27.9)

All Sensors

0.414
(10.5)

0.80
(20.3)

Description
+5V power supply input

DS-0009 Rev A
2-5

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

f 408 225 2079

In addition to synchronous communications, the Digital Output pressure sensors incorporates a bi-directional, TTL level,

Absolute Maximum Ratings

Environmental Specifications

Supply Voltage (Vcc)

Operating Voltage

7Vdc

Voltage on Any Pin with Respect to Gnd

Compensated Temperature

-0.6 to Vcc+0.6V

Common-mode pressure

-40 C to +125 C

Operating Temperature

50 psig

Lead Temperature (soldering 2-4 sec.)

+4.75Vdc to +5.25Vdc

-40 to +125 C

Storage Temperature

250C

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Operating Pressure

Units

(4)

Proof Pressure

Burst Pressure

5 INCH-D-DO-MIL

-5 to 5

inH2O

200 inH2O

300 inH2O

10 INCH-D-DO-MIL

-10 to 10

inH2O

10

200 inH2O

300 inH2O

1 PSI-D-DO-MIL

-1 to 1

PSI

200 inH2O

800 inH2O

5 PSI-D-DO-MIL

-5 to 5

PSI

10 PSI

30 PSI

15 PSI-D-DO-MIL

-15 to 15

PSI

15

60 PSI

120 PSI

15 PSI-A-DO-MIL

0 to 15

PSIA

15

60 PSI

120 PSI

600 to 1100

mBar

1100

60 PSI

120 PSI

30 PSI-D-DO-MIL

-30 to 30

PSI

30

90 PSI

150 PSI

30 PSI-A-DO-MIL

0 to 30

PSIA

30

90 PSI

150 PSI

-100 to 100

PSI

100

200 PSI

250 PSI

0 to 100

PSIA

100

200 PSI

250 PSI

Part Number

BARO-DO-MIL

100 PSI-D-DO-MIL
100 PSI-A-DO-MIL

FSO

(2)

Digital Span

General Performance Characteristics (All Models)


Parameter

Minimum

Nominal

Maximum

Units

12

--

--

Bit

Conversion Speed

--

16

mS

Supply Current

--

12

mA

Minimum

Nominal

Maximum

Units

--

0.5

1.0

%FSO

Long Term Drift (one year)

--

--

0.5

%FSO

Offset Position Sensitivity (1g)

--

--

0.05

%FSO

Offset Warm-up Shift

--

--

0.25

%FSO

(1)

Resolution

Performance Characteristics for 5 INCH-D-DO


Parameter

(1)

Overall Accuracy

(5)

(3)

Performance Characteristics for 10 INCH-D-DO and 1 PSI-D-DO


Parameter

Minimum

Nominal

Maximum

Units

--

0.5

1.0

%FSO

Long Term Drift (one year)

--

--

0.5

%FSO

Offset Position Sensitivity (1g)

--

--

0.03

%FSO

Offset Warm-up Shift

--

--

0.25

%FSO

(1)

Overall Accuracy

(5)

(3)

DigitalOutputMilitaryGradePressureSensors
2-5

Performance Characteristics for BARO-DO


Parameter (1)
Overall Accuracy

Minimum

Nominal

Maximum

Units

--

1.0

2.5

mBar

--

--

2.0

mBar

(5)

Long Term Drift (one year)

Parameter (1)
Overall Accuracy

Minimum

Nominal

Maximum

Units

--

0.25

0.5

%FSO

--

--

0.25

%FSO

(5)

Long Term Drift (one year)

e www.allsensors.com

Synchronous Timing Diagram (Note: Asynchronous mode timing is per RS-232. To use RS-232 requires the Maxim MA232
interface circuit for proper voltage level compatibility.)

READY [Output]
t1

t10
t2

all sensors

Performance Characteristics for 5 PSI-D-DO through 100 PSI-x-DO (except BARO-DO)

t2

CONVERT [Input]
t3
t8

t5

t9

f 408 225 2079

t4
CLOCK [Output]
t6

t7

Bit
15
MSB

Ref
t1
t2
t3
t4
t5

Parameter
Conversion Time
Ready to Convert
Convert to Clock
Clock Period
Clock High Time

Min
-0
24
---

Typ
8
-32
24
12

Bit
14

Max
16
-39
---

Bit
13

Bit
12

Bit
11

Bit
10

Units
msec
usec
usec
usec
usec

Bit
9

Bit
8

Ref
t6
t7
t8
t9
t10

Bit
7

Bit
6

Bit
5

Parameter
Data Setup Time
Data Hold Time
Interbyte Delay
Clock to Ready
Data Transmission

Bit
4

Bit
3

Min
------

Bit
2

Typ
3
3
70
14
476

Bit
1

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

DATA [Output]
Bit
0
LSB

Max
------

Units
usec
usec
usec
usec
usec

Typical Configurations
Synchronous Communications

Asynchronous Communications

Typical synchronous communications

Typical asynchronous communications

configuration (compatible with All

configuration. The Mode pin is

Sensors GA142 Series Digital Output

interrogated at power up and if tied

Sensors).

low, will cause the sensor to enter

Host
System

Sensor
Clock/SO
Data/SI
Convert/BR
Ready/Mode

All Sensors

asynchronous communications mode.


This mode supports multiple sensors by
addressable commands. The Convert/
BR pin then serves to select one of two
available baud rates.

Sensor
Host
System

(1)

Clock/SO
Data/SI
Convert/BR
Ready/Mode

Sensor

(n)

Clock/SO
Data/SI
Convert/BR
Ready/Mode

DS-0009 Rev A
2-5

Command Summary Table:


Command
Description

Response

RA<cr>

Read Accuracy String

RA=[Accuracy String]<cr>

RC<cr>

Read Captured Pressure

RC=[hhhh]<sp>[eeee]<cr>

RH<cr>

Read High Resolution Pressure

RH=[hhhh]<sp>[eeee]<cr>

RL<cr>

Read Low Resolution Pressure

RL[llll]<sp>[eeee]<cr>

RM<cr>

Read Model

RM=[Model String]<cr>

RR<cr>

Read Pressure Range

RR=[pressure Range String]<cr>

RS<cr>

Read Serial Number

RS=[S/N String]<cr>

RT<cr>

Read Temperature

RT=[Temperature Range String]<cr>

U[S/N String][Command]<cr>

Unique Command

For Matching S/N

U[S/N String],sp>[Response String]

For Non-matching S/N {null}


WC<cr>

Capture Pressure

{null}

Notations:
<> indicates a single ascii character
[] indicates an ascii string
{} text within the braces describes the response (this is essentially a comment)

16-Mar-03

text within quotes represents a literal ascii text string

Definitions:
Term

Name

Description

<cr>

Carriage Return

ascii Carrage Return. This is a command/response delimiter

<sp>

Space

ascii Space Character

[Accuracy String]

Accuracy String

Part accuracy string. Given in % full scale output.


Example: 0.250 %FSO
Notes:
1.) There is a space between the numeric accuracy 0.250
and units %FSO.
2.) FSO stands for Full Scale Output (full scale output is
determined by the Pressure Range String.)

[hhhh]

High Resolution Output

This is a four character ascii string representing a


hexidecimal value.
Example: 3F7C
Represents an output count of 16,252
Note: the output is forced to 8000 upon an error.
except error bit 8, see error bit codes.

[llll]

Low Resolution Output

This is a four character ascii string representing a


hexidecimal value.
Example: 1D58
Represents an output count of 7,512
Note: the output is forced to 8000 upon an error.
except error bit 8, see error bit codes.

[Model String]

Model String

Part Model as given in the data sheet (also order number.)


The general model syntax is
[Full Scale Pressure]<sp>[Pressure Units]-[Pressure Model]-DO
Example: 100 PSI-D-DO
Where:
Full Scale Pressure=100
Pressure Units=PSI (inH2O, mbar or mmHg available)
DO represents Digital Output
Notes:
1.) Exception to this syntax is the Barometer.
2.) Custom models may be different.

DigitalOutputMilitaryGradePressureSensors
2-5

Description

Pressure Range String

This is the compensated pressure range of the part.


Syntax: [low limit]<sp>to<sp>[high limit]<sp>[units}[mode]
Esample: 20 to 32 mmHgA
Where:
Low limit = 20
High limit = 32
Units = mmHg
Mode = A (absolute pressure) (D differential and G gage
pressure also available.)

[Response String]

A Fully Formed Response String

Example: RL=1E43<sp>0000<cr>

[S/N String]

Serial Number String

YMDD-NN-BSPP (12 character String)


Where:
Y : Year (0~9)
M : Month (A~M, excluding I)
DD: Day of Month
NN: Lot (lot sequence for a given day)
B : Lot Batch# (A~Z)
S : Test Oven Slot# (1~5)
P : Position on Slot (1~15)
Example: 3D23-03-A103

all sensors

Name

[Pressure Range String]

Month Codes

e www.allsensors.com

January : A
February : B
March
:C
April
:D
May
:E
June
:F
July
:G
August : H
September : J
October : K
November : L
December : M

[Temperature Range String]

Temperature Range String

This is the compensated temperature range of the part.


Syntax: [low limit]<sp>[high limit]<sp>C
Example: -20 to 85 C
-40 to 125 C and custom ranges also available.

[eeee]

Error Codes

The error codes are bits packed within a double byte.


The four character string is an ascii hex expression.
The error code bits are:
Bit 0 : Part not factory compensated
Bit 1 : Tdex Overflow
Bit 2 : Tdex Over-range
Bit 3 : Pdex Overflow
Bit 4 : Pdex Over-range
Bit 5 : PWL Overflow
Bit 6 : Scale Overflow
Bit 7 : High Resolution Overflow
Bit 8 : Pressure Output Limited to Specific Value
Bits 9 through 15 : Reserved

f 408 225 2079

April 23, 2003


3rd lot of the day
Batch A, Slot 1, Position 03
This allows traceability to original test data

Example: 0100
Represents error bit 8 set and the Pressure Output Limited
Notes:
Bit 0 : This should not appear if the part has been calibrated
Bits 1 thru 7 : indicate computational error when compensated
Bit 8: indicates that the pressure applied to the part exceeds the
range of the part and is limit to either the high or low limit
{null}

Null Response

No response from the part. In the event of a serial number


mismatch the part will not respond (to avoid buss contention.)

Specification Notes
NOTE 1:
NOTE 2:

NOTE 3:
NOTE 4:

NOTE 5:

UNLESS OTHERWISE SPECIFIED, ALL PARAMETERS ARE MEASURED AT 5.0 VOLT SUPPLY, POSITIVE PRESSURE APPLIED TO PORT B.
THE DIGITAL OUTPUT IS A 16 BIT SIGNED BINARY OUTPUT IN A TWOS COMPLIMENT FORMAT. THE APPLIED PRESSURE IS COMPUTED USING THE PRESSURE CONVERSION
TABLE (BELOW). THE MODE COLUMN IDENTIFIES THE RESOLUTION OPERATING MODE OF THE DEVICE (A = STANDARD RESOLUTION, B = HIGH RESOLUTION). FSO AND
UNITS ARE SHOWN FOR EACH MODEL.
SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
DIGITAL SPAN IS DEPENDENT ON THE RESOLUTION OPERATING MODE. REFER TO THE DIGITAL SPAN TABLE (BELOW) TO IDENTIFY THE DIGITAL SPAN OF THE SPECIFIC
MODEL. IN THE EVENT OF AN OVER-PRESSURE OR UNDER-PRESSURE CONDITION, THE DIGITAL OUTPUT WILL ONE COUNT HIGHER OR ONE COUNT LOWER (RESPECTIVELY) TO
THE LISTED DIGITAL SPAN TO INDICATE THE CONDITION.
OVERALL ACCURACY INCLUDES THE COMBINED EFFECTS OF OFFSET AND SPAN SHIFTS OVER TEMPERATURE, LINEARITY, HYSTERESIS, AND OFFSET AND SPAN CALIBRATION.

All Sensors

DS-0009 Rev A
2-5

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Definitions:
Term

DIGITALOUTPUTBAROMETERSENSORS
Enhanced Digital Output Sensors: Industrial temperature range

Features

all sensors

All Combined Errors Over Temperature Less Than 0.1%, Typical


Wide -20 to 85C Compensated Temperature Range
Electrically Compatible to All Sensors GA142 Series
Enhanced Dual Serial Interface Mode

Applications
Medical Instrumentation
Environmental Controls
Meteorology

e www.allsensors.com

General Description
The Digital Output pressure sensors are based upon a proprietary surface mapping technology to produce a fully digital
output that virtually eliminates all repeatable errors over temperature and pressure. This series provides a 12 bit digital
serial output (14 bit in High Resolution Mode) with superior offset, span and linearity characteristics. The output is SPI and
MICROWIRE/PLUS compatible as well as fully compatible with the All Sensors GA142 Series sensors.

asynchronous serial interfaces mode (hardware selectable 9,600 or 19,200 baud). This mode includes a command set that
allows the host to interrogate the sensor for model information, pressure range, serial number, pressure units and
conversion factor. The command set also allows the host to select a high resolution output mode, make minor adjustments
to offset and has an addressable feature that alows multiple sensors to be tied to the same interface buss.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. All signals
are 5V TTL/CMOS compatible.

Physical Dimensions
0.25
(6.4)

Pin Descriptions

0.174 to 0.190
(4.4 to 4.8)

Pin 1 2 3 4 5 6
0.21
(5.3)

A
1.08
(27.4)
0.66
(16.0)

0.48
(12.2)

Pin Label
1 Vcc

0.10
Typical
(2.54)

Pin Size
0.010 x 0.020
(0.25 x 0.50)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

Data/SI

Data output for synchronous


mode. Serial in for asynchronous mode.

Clock/SO

Clock output for synchronous


mode. Serial out for asynchronous mode.

Ready/Mode Ready output for synchronous


mode. Selects asynchronous
mode when held low during
reset.

Convert/BR

Convert input for synchronous


mode. Selects one of two
baud rates for asynchronous
mode (low=9,600,
high=19,200).

Ground

Ground for power and signals

0.42
(10.5)

0.80
(20.3)
0.85
(21.6)
1.10
(27.9)

Description
+5V power supply input

Pressure Applied to Port B

All Sensors

DS-0010 Rev A
2-6

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

f 408 225 2079

In addition to synchronous communications, the Digital Output pressure sensors incorporates a bi-directional, TTL level,

Absolute Maximum Ratings

Environmental Specifications

Supply Voltage (Vcc)

7Vdc

Voltage on Any Pin with Respect to Gnd

-0.6 to Vcc+0.6V

Lead Temperature (soldering 2-4 sec.)

250C

Operating Voltage

+4.75Vdc to +5.25Vdc

Compensated Temperature

-20C to +85 C

Operating Temperature

-20 to +105 C

Storage Temperature

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Units

Digital Span (4)

600 to 1100

mBar

60 PSI

120 PSI

inches Hg

60 PSI

120 PSI

BARO-DO
BARO-INHG-DO

20 to 32

Proof Pressure Burst Pressure

General Performance Characteristics


Parameter

Minimum

Nominal

Maximum

Units

12

--

--

Bit

Conversion Speed

--

16

mS

Supply Current

--

12

mA

--

1.0

2.5

mBar

--

0.025

2.0

mBar

(1)

Resolution

Overall Accuracy

(5)

Long Term Drift (one year)

Specification Notes
NOTE 1:
UNLESS OTHERWISE SPECIFIED, ALL PARAMETERS ARE MEASURED AT 5.0 VOLT SUPPLY, POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2:
THE DIGITAL OUTPUT IS A 16 BIT SIGNED BINARY OUTPUT IN A TWOS COMPLIMENT FORMAT. THE APPLIED PRESSURE IS COMPUTED USING THE PRESSURE
CONVERSION TABLE (BELOW). THE MODE COLUMN IDENTIFIES THE RESOLUTION OPERATING MODE OF THE DEVICE (A = STANDARD RESOLUTION, B = HIGH
RESOLUTION). FSO AND UNITS ARE SHOWN FOR EACH MODEL.
NOTE 3:
SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4:
DIGITAL SPAN IS DEPENDENT ON THE RESOLUTION OPERATING MODE. REFER TO THE DIGITAL SPAN TABLE (BELOW) TO IDENTIFY THE DIGITAL SPAN OF THE
SPECIFIC MODEL. IN THE EVENT OF AN OVER-PRESSURE OR UNDER-PRESSURE CONDITION, THE DIGITAL OUTPUT WILL ONE COUNT HIGHER OR ONE COUNT LOWER
(RESPECTIVELY) TO THE LISTED DIGITAL SPAN TO INDICATE THE CONDITION.
NOTE 5:
OVERALL ACCURACY INCLUDES THE COMBINED EFFECTS OF OFFSET AND SPAN SHIFTS OVER TEMPERATURE, LINEARITY, HYSTERESIS, AND OFFSET AND SPAN
CALIBRATION.

BarometerDigitalOutputPressureSensors
2-6

Synchronous Timing Diagram (Note: Asynchronous mode timing is per RS-232. To use RS-232 requires the Maxim MA232

all sensors

interface circuit for proper voltage level compatibility.)

READY [Output]
t1

t10
t2

t2

CONVERT [Input]
t3
t8

t5

t9

e www.allsensors.com

t4
CLOCK [Output]
t6

t7

DATA [Output]

Parameter
Conversion Time
Ready to Convert
Convert to Clock
Clock Period
Clock High Time

Min
-0
24
---

Typ
8
-32
24
12

Max
16
-39
---

Bit
13

Bit
12

Bit
11

Bit
10

Units
msec
usec
usec
usec
usec

Bit
9

Bit
8

Ref
t6
t7
t8
t9
t10

Bit
7

Bit
6

Bit
5

Parameter
Data Setup Time
Data Hold Time
Interbyte Delay
Clock to Ready
Data Transmission

Bit
4

Bit
3

Min
------

Bit
2

Typ
3
3
70
14
476

Bit
1

Bit
0
LSB

Max
------

f 408 225 2079

Ref
t1
t2
t3
t4
t5

Bit
14

Units
usec
usec
usec
usec
usec

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Bit
15
MSB

Typical Configurations
Synchronous Communications

Asynchronous Communications

Typical synchronous communications

Typical asynchronous communications

configuration (compatible with All Sensors

configuration. The Mode pin is interrogated

GA142 Series Digital Output Sensors).

at power up and if tied low, will cause the


sensor to enter asynchronous communica-

Host
System

Sensor
Clock/SO
Data/SI
Convert/BR

tions mode. This mode supports multiple


sensors by addressable commands. The
Convert/BR pin then serves to select one of
two available baud rates.

Ready/Mode

All Sensors

Sensor
Host
System

(1)

Clock/SO
Data/SI
Convert/BR
Ready/Mode

Sensor

(n)

Clock/SO
Data/SI
Convert/BR
Ready/Mode

DS-0010 Rev A
2-6

Command Summary Table:


Command
Description

Response

RA<cr>

Read Accuracy String

RA=[Accuracy String]<cr>

RC<cr>

Read Captured Pressure

RC=[hhhh]<sp>[eeee]<cr>

RH<cr>

Read High Resolution Pressure

RH=[hhhh]<sp>[eeee]<cr>

RL<cr>

Read Low Resolution Pressure

RL[llll]<sp>[eeee]<cr>

RM<cr>

Read Model

RM=[Model String]<cr>

RR<cr>

Read Pressure Range

RR=[pressure Range String]<cr>

RS<cr>

Read Serial Number

RS=[S/N String]<cr>

RT<cr>

Read Temperature

RT=[Temperature Range String]<cr>

U[S/N String][Command]<cr>

Unique Command

For Matching S/N

U[S/N String],sp>[Response String]

For Non-matching S/N {null}


WC<cr>

Capture Pressure

{null}

Notations:
<> indicates a single ascii character
[] indicates an ascii string
{} text within the braces describes the response (this is essentially a comment)

16-Mar-03
16-Mar-03

text within quotes represents a literal ascii text string

Definitions:
Term

Name

Description

<cr>

Carriage Return

ascii Carrage Return. This is a command/response delimiter

<sp>

Space

ascii Space Character

[Accuracy String]

Accuracy String

Part accuracy string. Given in % full scale output.


Example: 0.250 %FSO
Notes:
1.) There is a space between the numeric accuracy 0.250
and units %FSO.
2.) FSO stands for Full Scale Output (full scale output is
determined by the Pressure Range String.)

[hhhh]

High Resolution Output

This is a four character ascii string representing a


hexidecimal value.
Example: 3F7C
Represents an output count of 16,252
Note: the output is forced to 8000 upon an error.
except error bit 8, see error bit codes.

[llll]

Low Resolution Output

This is a four character ascii string representing a


hexidecimal value.
Example: 1D58
Represents an output count of 7,512
Note: the output is forced to 8000 upon an error.
except error bit 8, see error bit codes.

[Model String]

Model String

Part Model as given in the data sheet (also order number.)


The general model syntax is
[Full Scale Pressure]<sp>[Pressure Units]-[Pressure Model]-DO
Example: 100 PSI-D-DO
Where:
Full Scale Pressure=100
Pressure Units=PSI (inH2O, mbar or mmHg available)
DO represents Digital Output
Notes:
1.) Exception to this syntax is the Barometer.
2.) Custom models may be different.

BarometerDigitalOutputPressureSensors
2-6

Description

Pressure Range String

This is the compensated pressure range of the part.


Syntax: [low limit]<sp>to<sp>[high limit]<sp>[units}[mode]
Esample: 20 to 32 mmHgA
Where:
Low limit = 20
High limit = 32
Units = mmHg
Mode = A (absolute pressure) (D differential and G gage
pressure also available.)

[Response String]

A Fully Formed Response String

Example: RL=1E43<sp>0000<cr>

[S/N String]

Serial Number String

YMDD-NN-BSPP (12 character String)


Where:
Y : Year (0~9)
M : Month (A~M, excluding I)
DD: Day of Month
NN: Lot (lot sequence for a given day)
B : Lot Batch# (A~Z)
S : Test Oven Slot# (1~5)
P : Position on Slot (1~15)
Example: 3D23-03-A103

all sensors

Name

[Pressure Range String]

Month Codes

e www.allsensors.com

January : A
February : B
March
:C
April
:D
May
:E
June
:F
July
:G
August : H
September : J
October : K
November : L
December : M

[Temperature Range String]

Temperature Range String

This is the compensated temperature range of the part.


Syntax: [low limit]<sp>[high limit]<sp>C
Example: -20 to 85 C
-40 to 125 C and custom ranges also available.

[eeee]

Error Codes

The error codes are bits packed within a double byte.


The four character string is an ascii hex expression.
The error code bits are:
Bit 0 : Part not factory compensated
Bit 1 : Tdex Overflow
Bit 2 : Tdex Over-range
Bit 3 : Pdex Overflow
Bit 4 : Pdex Over-range
Bit 5 : PWL Overflow
Bit 6 : Scale Overflow
Bit 7 : High Resolution Overflow
Bit 8 : Pressure Output Limited to Specific Value
Bits 9 through 15 : Reserved

f 408 225 2079

April 23, 2003


3rd lot of the day
Batch A, Slot 1, Position 03
This allows traceability to original test data

Example: 0100
Represents erro bit 8 set and the Pressure Output Limited
Notes:
Bit 0 : This should not appear if the part has been calibrated
Bits 1 thru 7 : indicate computational error when compensated
Bit 8: indicates that the pressure applied to the part exceeds the
range of the part and is limit to either the high or low limit
{null}

Null Response

No response from the part. In the event of a serial number


mismatch the part will not respond (to avoid buss contention.)

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.
MICROWIRE/PLUS

IS A REGISTERED TRADEMARK OF

All Sensors

NATIONAL SEMICONDUCTOR.

DS-0010 Rev A
2-6

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Definitions:
Term

DIGITAL OUTPUT BAROMETER SENSORS


Enhanced Digital Output Sensors: Extended temperature range

Features

all sensors

All Combined Errors Over Temperature Less Than 0.1%, Typical


Wide -40 to 125C Compensated Temperature Range
Electrically Compatible to All Sensors GA142 Series
Enhanced Dual Serial Interface Mode

Applications
Medical Instrumentation
Environmental Controls
Meteorology

e www.allsensors.com

General Description
The Digital Output pressure sensors are based upon a proprietary surface mapping technology to produce a fully digital
output that virtually eliminates all repeatable errors over temperature and pressure. This series provides a 12 bit digital
serial output (14 bit in High Resolution Mode) with superior offset, span and linearity characteristics. The output is SPI and
MICROWIRE/PLUS compatible as well as fully compatible with the All Sensors GA142 Series sensors.

asynchronous serial interfaces mode (hardware selectable 9,600 or 19,200 baud). This mode includes a command set that
allows the host to interrogate the sensor for model information, pressure range, serial number, pressure units and
conversion factor. The command set also allows the host to select a high resolution output mode, make minor adjustments
to offset and has an addressable feature that alows multiple sensors to be tied to the same interface buss.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. All signals
are 5V TTL/CMOS compatible.

Physical Dimensions
0.25
(6.4)

Pin Descriptions

0.174 to 0.190
(4.4 to 4.8)

Pin 1 2 3 4 5 6
0.21
(5.3)

A
1.08
(27.4)
0.66
(16.0)

0.48
(12.2)

Pin Label
1 Vcc

0.10
Typical
(2.54)

Pin Size
0.010 x 0.020
(0.25 x 0.50)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

Data/SI

Data output for synchronous


mode. Serial in for asynchronous mode.

Clock/SO

Clock output for synchronous


mode. Serial out for asynchronous mode.

Ready/Mode Ready output for synchronous


mode. Selects asynchronous
mode when held low during
reset.

Convert/BR

Convert input for synchronous


mode. Selects one of two
baud rates for asynchronous
mode (low=9,600,
high=19,200).

Ground

Ground for power and signals

0.42
(10.5)

0.80
(20.3)
0.85
(21.6)
1.10
(27.9)

Description
+5V power supply input

Pressure Applied to Port B

All Sensors

DS-0011 Rev A
2-7

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

f 408 225 2079

In addition to synchronous communications, the Digital Output pressure sensors incorporates a bi-directional, TTL level,

Absolute Maximum Ratings

Environmental Specifications

Supply Voltage (Vcc)

7Vdc

Voltage on Any Pin with Respect to Gnd

-0.6 to Vcc+0.6V

LeadTemperature (soldering 2-4 sec.)

250C

Operating Voltage

+4.75Vdc to +5.25Vdc

Compensated Temperature

-40C to +125 C

Operating Temperature

-40 to +125 C

Storage Temperature

-40 to 150 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Units

Digital Span (4)

Proof Pressure

Burst Pressure

600 to 1100

mBar

60 PSI

120 PSI

20 to 32

inches Hg

60 PSI

120 PSI

BARO-DO-MIL
BARO-INHG-DO-MIL
BARO-DO-MIL-PCB
BARO-INHG-DO-MIL-PCB

600 to 1100
20 to 32

mBar
inches Hg

60 PSI

120 PSI

60 PSI

120 PSI

General Performance Characteristics


Parameter

(1)

Minimum

Nominal

Maximum

Units

12

--

--

Bit

Conversion Speed

--

16

mS

Supply Current

--

12

mA

--

1.0

2.5

mBar

--

--

2.0

mBar

Resolution

Overall Accuracy

(5)

Long Term Drift (one year)

Specification Notes
NOTE
NOTE

NOTE
NOTE

NOTE

1: UNLESS OTHERWISE SPECIFIED, ALL PARAMETERS ARE MEASURED AT 5.0 VOLT SUPPLY, POSITIVE PRESSURE APPLIED TO P ORT B.
2: THE DIGITAL OUTPUT IS A 16 BIT SIGNED BINARY OUTPUT IN A TWOS COMPLIMENT FORMAT. THE APPLIED PRESSURE IS COMPUTED USING THE PRESSURE
CONVERSION TABLE (BELOW). THE MODE COLUMN IDENTIFIES THE RESOLUTION OPERATING MODE OF THE DEVICE (A = STANDARD RESOLUTION, B =
HIGH RESOLUTION). FSO AND UNITS ARE SHOWN FOR EACH MODEL.
3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
4: DIGITAL SPAN IS DEPENDENT ON THE RESOLUTION OPERATING MODE. REFER TO THE DIGITAL SPAN TABLE (BELOW) TO IDENTIFY THE DIGITAL SPAN OF THE
SPECIFIC MODEL. IN THE EVENT OF AN OVER- PRESSURE OR UNDER-PRESSURE CONDITION, THE DIGITAL OUTPUT WILL ONE COUNT HIGHER OR ONE COUNT
LOWER ( RESPECTIVELY) TO THE LISTED D IGITAL SPAN TO INDICATE THE CONDITION.
5: OVERALL ACCURACY INCLUDES THE COMBINED EFFECTS OF OFFSET AND SPAN SHIFTS OVER TEMPERATURE, LINEARITY , HYSTERESIS , AND OFFSET AND SPAN
CALIBRATION .
Pressure Conversion Table

Error Code Table (Asynchronous mode)


Bit 0 : Part not compensated
Bit 1 : Tdex Overflow
Bit 2 : Tdex Over-range
Bit 3 : Pdex Overflow
Bit 4 : Pdex Over-range
Bit 5 : PWL Overflow
Bit 6 : Scaling Overflow
Bit 7 : High resolution overflow
Bit 8 : Pressure Output Limited to Specified Value
Bit 9 through Bit 15 : Reserved

Mode

Pressure Output Equation

Pout = Digital Output x

FSO x Units
10,000

Pout = Digital Output x

FSO x Units
32,767

Digital Span Table


Span
1
2
3

Mode S (Standard)

Mode H (High Res)

-10,399 to 10,399
-399 to 10,399
5,054 to 10,399

-32,767 to 32,766
-999 to 32,766
17,501 to 32,766

Barometer Digital Output Pressure Sensors


2-7

all sensors

Option: PCB mounted compatible to GA-series and SMRT series

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

f 408 225 2079

e www.allsensors.com

Optional 90 degree lead bend

Typical Configurations
Synchronous Communications

Asynchronous Communications

Typical synchronous communications

Typical asynchronous communications

configuration (compatible with All

configuration. The Mode pin is

Sensors GA142 Series Digital Output

interrogated at power up and if tied

Sensors).

low, will cause the sensor to enter

Host
System

Sensor
Clock/SO
Data/SI
Conv ert/BR
Ready/Mode

Sensor (1)
Host
System

Clock/SO
Data/SI
Convert /BR
Ready/Mode

asynchronous communications mode.

Sensor (n)

This mode supports multiple sensors by

Clock/SO
Data/SI
Convert /BR
Ready/Mode

addressable commands. The Convert/


BR pin then serves to select one of two
available baud rates.

All Sensors

DS-0011 Rev A
2-7

Asynchronous Command Summary

(1,2)

Command

Description

Response

RD

Read Mode Setting

RD=<Mode>

RM

Read Model Information

RM=<Model String>

RO

Read User Offset Setting

RO=<hhhh>

RP

Read Pressure

RP=<hhhh>

RR

Read Device Pressure Range

RR=<Range String>

RS

Read Serial Number

RS=<Serial Number String>

WD<Mode>

Write Mode Setting (S = Standard, H = High Resolution)

WD=<Mode>

WO<Offset>

Write User Offset Setting

WO=<hhhh>

U<S/N><Cmd>

Select Unique Part for following command (for multidrop


configurations).

U<S/N><Cmd>

Asynchronous Command Notes


NOTE

1:

ALL

ASCII CHARACTER FORMAT AND ARE TERMINATED BY A CARRIAGE RETURN (CARRIAGE RETURNS ARE NOT SHOWN IN
EXAMPLE: THE READ HIGH RESOLUTION PRESSURE COMMAND (REPRESENTED BY: RH<CR>) IS GIVEN BY THE FOLLOWING
THREE BYTE SEQUENCE: 0X52 0X48 0X0D
<hhhh> IS A FOUR BYTE ASCII STRING REPRESENTING A 16-BIT SIGNED VALUE. EXAMPLE: RH=2B7D REPRESENTS THE RESPONSE OF AN RH COMMAND WITH
THE PRESSURE OUTPUT OF 0X2B7D (11,133 DECIMAL) VALUE.
<LLLL> IS A FOUR BYTE ASCII STRING REPRESENTING THE LOW RESOLUTION OUTPUT (SIMILAR TO THE HIGH RESOLUTION RESPONSE OF NOTE 2)
<eeee> IS A 16-BIT ERROR CODE. THE REPRESENTATION IS FOUR BYTE ASCII STRING (EXPRESSING A DOUBLE-BYTE OR 16-BITS). A NO ERROR CONDITION IS
EXPRESSED AS 0000 WHERE AN ERROR IS EXPRESSED BY SETTING AN INDIVIDUAL BIT OF THE ERROR WORD AND PRESENTING IT IN ASCII HEX FORMAT.
{NULL} IS A NULL RESPONSE (NO RESPONSE). THE INTENT UTILITY OF THE COMMAND IS TO APPLY THIS COMMAND IN A MULTIDROP CONFIGURATION (BUSSED
CONFIGURATION) AND SIMULANEOUSLY CAPTURE THE PRESSURE OF ALL OF THE DEVICES ON THE BUSS. THE CAPTURED READINGS CAN SUBSEQUENTLY BE READ USING
THE U COMMAND (SELECT UNIQUE PART) INCONJUNCTION WITH THE RC COMMAND. EXAMPLE: U<S/N>RC<CR>
COMMANDS AND RESPONSES ARE IN

COMMAND AND RESPONSE TABLE).

NOTE

2:

NOTE
NOTE

3:
4:

NOTE

5:

16-Mar-03

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
MICROWIRE/PLUS

IS A REGISTERED TRADEMARK OF

NATIONAL SEMICONDUCTOR.

Barometer Digital Output Pressure Sensors


2-7

CPA 502
Piezoresistive ceramic pressure
sensor with flush membrane

Digital calibrated

Ratiometric output signal (0.5 to 4.5 V)

Excellent chemical resistance

Easy mounting

Pressure ranges
7,5 to 750 psi gauge, absolute
1500 to 9000 psi sealed gauge

Standard Pressure Ranges


Proof pressure

PSI1)

bar
1)

7.5 2)
15
30
75
150
300
750
1500 3)
3000 3)
6000 3)
9000 3)

0.5 2)
1
2
5
10
20
50
100 3)
200 3)
400 3)
600 3)

[PSI /bar]
15
1
30
2
60
4
150
10
225
15
525
35
1500
100
2250
150
5250
350
7500
500
11250
750

Admissible negative
pressure
[PSI1)/bar]
-2
- 0.15
-3
- 0.20
-6
- 0.40
-11,5
- 0.80

vacuum resistant

Burst pressure

Output signal

Sensor thickness

1)

[V]

[mm]
6.13
6.20
6.25
6.30
6.35
6.55
6.70
6.70
7.05
7.35
7.55

[PSI /bar]
30
2
45
3
90
6
180
12
300
20
750
50
1800
120
3000
200
7500
500
9750
650
14250
950

0.5 to 4.5 V
(@ Vs = 5 VDC)

Reference Conditions
Supply voltage
Output signal /Supply

4.5 to 5.5 V
3-wire ratiometric: 10 to 90% of VS (V0 = 0.5 to 4.5 VDC @ Vs = 5.0 V)

Reference temperature

25 C

Measuring supply voltage

5 VDC

Performance Characteristics
Supply current

2.5 mA

Offset

0.5 V @ Vs = 5 V

Span

4.0 V @ Vs = 5 V

Output load resistance


Total error

5 k

(Nonlinearity, hysteresis, nonrepeatability)

Pressure ranges: 0.4 % FS (terminal based)

Calibration error

0.3 %FS

Long term stability

0.3 % FS / year (at reference conditions)

TC Offset (TC0)

0.02 % FS/ C

TC Span (TCS)

- 0.013 % FS/ C

4)
4)

1)

PSI values around rounded and for reference only


only gauge available
only sealed gauge available
4)
over compensated temperature range
2)
3)

DS-0339 Rev A
Page 1 of 2

Tel:
Fax:

408.225.4314
408.225.2079

www.allsensors.com
info@allsensors.com

CPA-502
Ceramic pressure sensor

Specifications

Enviromental Specification
Operating temperature range
Storage temperature range
Compensated temperature range

- 40 to 85 C
- 40 to 100 C
0 to 85 C

Electrical connections
on PCB of sensor
on connection wire

Mates with JST socket parts: B3B-ZR-SM4-TF


Connection housing: ZHR-3
Connection pin:

Applicable wire
Model No.

[mm ]

AWG#

SZH-002T-P0.5

0.08 ~ 0.13

28 ~ 26

Insulation
O.D.[mm]
0.8 ~ 1.1

SZH-003T-P0.5

0.032 ~ 0.08

32 ~ 28

0.5 ~ 0.9

Miscellaneous
Material in contact with the media

Ceramic Al2O3 96 %

Weight

approx. 9 g

Dimensions

= 18 0.1 mm

d = 6.13 to 7.55 0.1 (excl. signal conditioning board)

Mechanical
Drawing

Pinout information
JST socket B3B-ZR-SM4-TF
2

Pin Out
1: +5 V
2: GND
3: signal

This data sheet contains product specification, properties are not guaranteed. Subject to be changed without notice.

Ordering code

CPA - 502 -

Type of pressure
absolute
gauge
sealed gauge

A
G
S

Pressure range
7.5 psi / (only gauge) 0.5 bar
15 psi / 1 bar
30 psi / 2 bar
75 psi / 5 bar
150 psi / 10 bar
300 psi / 20 bar
750 psi / 50 bar
1500 psi / (only sealed gauge) 100 bar
3000 psi / (only sealed gauge) 200 bar
6000 psi / (only sealed gauge) 400 bar
9000 psi / (only sealed gauge) 600 bar
Electrical connection
JST socket
Others on request
Options
Standard

DS-0339 Rev A
Page 2 of 2

L
0
0
0
1
3
7
1
3
6
9

7
1
3
7
5
0
5
K
K
K
K

5
5
0
5
0
0
0
5
0
0
0
3 0 1
9 9 9
0 0 1

Tel:
Fax:

408.225.4314
408.225.2079

www.allsensors.com
info@allsensors.com

CPA 602
Piezoresistive Monolithic
Ceramic Pressure Sensor

Digital calibrated

Ratiometric output signal (0.5 to 4.5 V)

Excellent chemical resistance

Easy mounting

Pressure ranges
30 to 6000 psi gauge

Standard Pressure Ranges


Proof pressure
PSI

1)

bar
[PSI1)/bar]

30
75
150
300
750
1500
3000
6000
other on request

2
5
10
20
50
100
200
400

60
150
300
600
1500
2250
4500
7500

Admissible
negative pressure
[PSI1)/bar]

4
10
20
40
100
150
300
500

vacuum
resistant

Burst pressure

Output signal

[PSI1)/bar]
8
20
35
60
140
300
400
650

120
300
525
900
2100
4500
6000
9750

0.5 to 4.5
V
(@ Vs =
5VDC)

Reference Conditions
Supply voltage

4.5 to 5.5 VDC

Output signal / Supply


Reference temperature

3-wire ratiometric: 10 to 90% of Vs (V0 = 0.5 to 4.5 VDC @ VS = 5.0 V)


25 C

Measuring supply voltage

5 VDC

Performance Characteristics
Supply current

2.5 mA

Offset

0.5 V @ Vs = 5 V

Span

4.0 V @ Vs = 5 V

Output load resistance

5 k
Pressure ranges: 750 psi: 0.4 % FS (terminal based)
Pressure ranges: > 750 psi: 0.8 % FS typ. (1.5 % FS max.) (terminal based)

Total error
(non-linearity, hysteresis,
non-repeatability)

(reduced error upon costumer request)

Calibration error

0.3 % FS

Long term stability

0.3 % FS/year (at reference conditions)

TC Offset (TC0)

0.02 % FS / C

TC Span (TCS)

1)
2)

2)

- 0.012 % FS / C 2)

PSI values around rounded and for reference only


over compensated temperature range

DS-0340 Rev A
Page 1 of 2

Tel:
Fax:

408.225.4314
408.225.2079

www.allsensors.com
info@allsensors.com

CPA-602
Ceramic pressure sensor

Specifications

Environmental Specification
Operating temperature range

- 40 to 85 C

Storage temperature range

- 40 to 100 C

Compensated temperature range

0 to 85 C

Electrical connection
on PCB of sensor
on connection wire

Mates with JST socket parts: B3B-ZR-SM4-TF


Connection housing: ZHR-3
Connection pin:
Model No.
[mm]
SZH-002T-P0.5
SZH-003T-P0.5

Applicable wire
AWG#

0.08 ~ 0.13
0.032 ~ 0.08

28 ~ 26
32 ~ 28

Insulation
O.D.[mm]
0.8 ~ 1.1
0.5 ~ 0.9

Miscellaneous
Media wetted parts

Ceramic Al2O3 96 %

Weight

approx. 7 g

Dimension

= 18 0.1 mm

d = 6.35 0.1 mm (excl. signal conditioning board)

Mechanical
Drawing

Pinout information
JST socket B3B-ZR-SM4-TF
3

Pin Out
1: +5 V
2: GND
3: signal

CPA - 602 -

This data sheet contains product specification, properties are not guaranteed. Subject to be changed without notice.

Ordering code

Type of pressure
gauge

Pressure ranges
30 psi / 2 bar
75 psi / 5 bar
150 psi / 10 bar
300 psi / 20 bar
750 psi / 50 bar
1500 psi / 100 bar
3000 psi / 200 bar
6000 psi / 400 bar

0
0
1
3
7
1
3
6

3
7
5
0
5
K
K
K

0
5
0
0
0
5
0
0

Electrical connection
JST socket
Others on request

3 0 1
9 9 9

Options
Standard

DS-0340 Rev A
Page 2 of 2

0 0 1

Tel:
Fax:

408.225.4314
408.225.2079

www.allsensors.com
info@allsensors.com

Amplified Very Low Pressure Sensors


AMPLIFIED Pressure Sensors

Features
0.25 and 0.50 In H2O Pressure Ranges
Ratiometric 4V Output
Temperature Compensated
Calibrated Zero and Span

Applications

all sensors

Medical Breathing
HVAC

General Description
The Amplified line of low pressure sensor is based upon a proprietary technology to reduce all output offset or common mode errors.
This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to change in

e www.allsensors.com

temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to
conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure
to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series

f 408 225 2079

is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Physical Dimensions

Vs

1.27
0.050

0.020" x 0.010" Pin


0.30" minimum length

Gnd
27.43
1.080

5.33
0.210

Port B

Vout

+
10.67
0.420

10.67
0.420
3.56
0.140

Port A

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Pin 1 Identifier

3.18
0.125

Port 0.179"/0.189"

CL

p 408 225 4314

2.54
0.100
(Typ)

8.74
0.344

Equivalent Circuit

3.18
R0.125

pin 1: Vsupply
12.19
0.480

13.97
0.550

20.32
0.800

pin 2: Common

21.59
0.850

pin 3: Voutput
pin 4: do not connect

All Sensors

DS-0032 Rev B
3-3

Pressure Sensor Ratings


Supply Voltage, Vs
Common-mode pressure

Environmental Specifications
+4.5 to +5.5 Vdc

Temperature Ranges

-10 to +10 psig

Compensated

270C

Lead Temperature, max (soldering 2-4 sec.)

5 to 50 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Device

Operating Range

Proof Pressure

Burst Pressure

Nominal Span (5)

0.25 INCH-D-4V

0.25 inH2O

40 inH2O

80 inH2O

2.0 V

0.25 INCH-G-4V

0.25 inH2O

40 inH2O

80 inH2O

4.0 V

0.5 INCH-D-4V

0.5 inH2O

40 inH2O

80 inH2O

2.0 V

0.5 INCH-G-4V

0.5 inH2O

40 inH2O

80 inH2O

4.0 V

Performance Characteristics for: 0.25 INCH-D-4V


Parameter, note 1

note

Minimum

Nominal

Maximum

Units

Output Span note 5

1.90

2.0

2.1

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

60

mV

Offset Warm-up Shift, note 3

20

mV

Offset Position Sensitivity (1g)

20

mV

Offset Long Term Drift (one year)

20

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Temperature Shift, note 2

%FSS

Minimum

Nominal

Maximum

Units

Output Span note 5

3.9

4.0

4.1

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

60

mV

Offset Warm-up Shift, note 3

20

Offset Position Sensitivity (1g)

20

mV

Offset Long Term Drift (one year)

20

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Temperature Shift, note 2

%FSS

Performance Characteristics for: 0.25 INCH-G-4V note 1


Parameter, note 1

mV

Amplified Very Low Pressure Sensors


3-3

Parameter, note 1

Minimum

Nominal

Maximum

Units

Output Span note 5

1.90

2.0

2.1

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

60

mV

Offset Warm-up Shift, note 3

20

mV

Offset Position Sensitivity (1g)

20

mV

Offset Long Term Drift (one year)

20

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Temperature Shift, note 2

%FSS

Minimum

Nominal

Maximum

Units

Output Span note 5

3.9

4.0

4.1

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

60

mV

Offset Warm-up Shift, note 3

20

mV

Offset Position Sensitivity (1g)

20

mV

Offset Long Term Drift (one year)

20

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Temperature Shift, note 2

%FSS

all sensors

Performance Characteristics for: 0.5 INCH-D-4V note 1

f 408 225 2079

Specification Notes
note

1: All parameters are measured at 5.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified.
with positive pressure applied to

2:
3:
note 4:
note 5:
note
note

Port B.

Pressure measurements are

Shift is relative to 25C.


Shift is within the first hour of excitation applied to the device.
Measured at one-half full scale rated pressure using best straight line curve fit.
The span is the algebraic difference between full scale output voltage and the offset voltage.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

All Sensors

DS-0032 Rev B
3-3

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for: 0.5 INCH-G-4V note 1

Amplified Low Pressure Sensors


1 mbar (0.4 In H2O) to 60 In H2O Pressure Sensors

Features
0 to 1 mbar to 0 to 60 In H2O Pressure Ranges
Ratiometric 4V Output
Temperature Compensated
Calibrated Zero and Span

Applications

all sensors

Medical Instrumentation
Environmental Controls
HVAC

General Description
The Amplified line of low pressure sensors are based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to change in

e www.allsensors.com

temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to
conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure
to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series

f 408 225 2079

is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

Physical Dimensions

p 408 225 4314

The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Equivalent Circuit
2.54
0.100
(Typ)

8.74
0.344

1.27
0.050

0.020" x 0.010" Pin


0.30" minimum length

Vs

Port B

27.43
1.080

5.33
0.210

10.67
0.420

10.67
0.420

Port A

3.56
0.140

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Pin 1 Identifier

3.18
0.125

Port 0.179"/0.189"

CL

Vout

3.18
R0.125

Gnd
12.19
0.480

13.97
0.550

20.32
0.800

Pinout:
Pin 1: Vs
Pin 2: Gnd
Pin 3: Vout
Pin 4: Do Not Connect

21.59
0.850

Approvals
MKT DATE

As Is

With Change

MFG DATE

As Is

All Sensors

With Change

ENG DATE

As Is

With Change

QA DATE

As Is

With Change

DS-0024 Rev C
3-4

Pressure Sensor Ratings

Environmental Specifications
+4.5 to +5.5 Vdc

Supply Supply Voltage VS

Temperature Ranges

-10 to +10 psig

Common-mode pressure

Compensated

250C

Lead Temperature, max


(soldering 2-4 sec.)

5 to 50 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

1 MBAR-D-4V

1 mbar

1 INCH-D-4V

Nominal Span

Proof Pressure

Burst Pressure

4V

100 InH2O

200 InH2O

1 InH2O

4V

100 InH2O

200 InH2O

1 INCH-G-4V

0 - 1 InH2O

4V

100 InH2O

200 InH2O

2.5 INCH-D-4V

2.5 InH2O

4V

200 InH2O

300 InH2O

2.5 INCH-G-4V

0 - 2.5 InH2O

4V

200 InH2O

300 InH2O

5 INCH-D-4V

5 InH2O

4V

200 InH2O

300 InH2O

5 INCH-G-4V

0 - 5 InH2O

4V

200 InH2O

300 InH2O

10 INCH-D-4V

10 InH2O

4V

200 InH2O

300 InH2O

10 INCH-G-4V

0 - 10 InH2O

4V

200 InH2O

300 InH2O

20 INCH-D-4V

20 InH2O

4V

300 InH2O

500 InH2O

20 INCH-G-4V

0 - 20 InH2O

4V

300 InH2O

500 InH2O

30 INCH-D-4V

30 InH2O

4V

500 InH2O

800 InH2O

30 INCH-G-4V

0 - 30 InH2O

4V

500 InH2O

800 InH2O

40 INCH-G-4V

0 - 40 InH2O

4V

500 InH2O

800 InH2O

60 INCH-G-4V

0 - 60 InH2O

4V

500 InH2O

800 InH2O

Performance Characteristics for: 1 MBAR-D-4V


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal

Maximum

1.0

Units
mbar

1.80

2.0

2.20

2.00

2.25

2.50

120

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

20

mV

Offset Position Sensitivity (1g)

40

mV

Offset Long Term Drift (one year)

20

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

DS-0024 Rev C

0.25

%FSS

%FSS

Amplified Low Pressure Sensors


3-4

Performance Characteristics for 1 INCH-D-4V


Minimum

Operating Range, differential pressure

Nominal

Maximum

1.0

Output Span, note 5


Offset Voltage @ zero differential pressure

Units
inH2O

1.90

2.0

2.10

2.15

2.25

2.35

60

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

10

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

10

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

Maximum

Units

all sensors

Parameter, note 1

Operating Range, gage pressure

Nominal
1.0

inH2O

Output Span, note 5

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

60

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

10

mV

Offset Position Sensitivity (1g)

15

mV

Offset Long Term Drift (one year)

10

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

Maximum

Units

f 408 225 2079

Minimum

p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 1 INCH-G-4V

Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal
2.5

inH2O

1.90

2.0

2.10

2.15

2.25

2.35

60

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

All Sensors

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Performance Characteristics for 2.5 INCH-D-4V

0.25

%FSS

%FSS

DS-0024 Rev C
3-4

Performance Characteristics for 2.5 INCH-G-4V


Parameter, note 1

Minimum

Operating Range, gage pressure

Nominal

Maximum

2.5

Units
inH2O

Output Span, note 5

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

60

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

Performance Characteristics for 5 INCH-D-4V


Parameter, note 1

Minimum

Operating Range, differential pressure

Nominal

Maximum

5.0

Output Span, note 5

Units
inH2O

1.90

2.0

2.10

2.15

2.25

2.35

40

mV

Offset Voltage @ zero differential pressure


Offset Temperature Shift (5C-50C), note 2
Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

Maximum

Units

Performance Characteristics for: 5 INCH-G-4V


Parameter, note 1

Minimum

Operating Range, gage pressure

Nominal
5.0

inH2O

Output Span, note 5

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

40

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

DS-0024 Rev C

0.25

%FSS

%FSS

Amplified Low Pressure Sensors


3-4

Performance Characteristics for: 10 INCH-D-4V


Minimum

Operating Range, differential pressure

Nominal

Maximum

10.0

Output Span, note 5


Offset Voltage @ zero differential pressure

Units
inH2O

1.90

2.0

2.10

2.15

2.25

2.35

20

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

Maximum

Units

all sensors

Parameter, note 1

Operating Range, gage pressure

Nominal
10.0

inH2O

Output Span, note 5

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

20

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

Maximum

Units

f 408 225 2079

Minimum

p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for: 10 INCH-G-4V

Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal
20.0

inH2O

1.90

2.0

2.10

2.15

2.25

2.35

20

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

All Sensors

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Performance Characteristics for 20 INCH-D-4V

0.25

%FSS

%FSS

DS-0024 Rev C
3-4

Performance Characteristics for 20 INCH-G-4V


Parameter, note 1

Minimum

Operating Range, gage pressure

Nominal

Maximum

20.0

Units
inH2O

Output Span, note 5

3.90

4.0

4.1

Offset Voltage @ zero pressure

0.15

0.25

0.35

20

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

Performance Characteristics for 30 INCH-D-4V


Parameter, note 1

Minimum

Operating Range, differential pressure

Nominal

Maximum

30.0

Output Span, note 5

Units
inH2O

1.90

2.0

2.10

2.15

2.25

2.35

20

mV

Offset Voltage @ zero differential pressure


Offset Temperature Shift (5C-50C), note 2
Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

Maximum

Units

Performance Characteristics for 30 INCH-G-4V


Parameter, note 1

Minimum

Operating Range, gage pressure

Nominal
30.0

Output Span, note 5


Offset Voltage @ zero pressure

inH2O

3.9

4.0

4.1

0.15

0.25

0.35

20

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

DS-0024 Rev C

0.25

%FSS

%FSS

Amplified Low Pressure Sensors


3-4

Performance Characteristics for 40 INCH-G-4V


Maximum

40.0

Output Span, note 5


Offset Voltage @ zero pressure

Units
inH2O

3.9

4.0

4.1

0.15

0.25

0.35

20

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

0.25

%FSS

%FSS

all sensors

Operating Range, gage pressure

Nominal

Performance Characteristics for 60 INCH-G-4V


Operating Range, gage pressure

Maximum

60.0

Output Span, note 5


Offset Voltage @ zero pressure

Nominal

Units
inH2O

3.9

4.0

4.1

0.15

0.25

0.35

20

mV

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

Span Temperature Shift (5C-50C), note 2

e www.allsensors.com

Minimum

0.25

%FSS

%FSS

f 408 225 2079

Parameter, note 1

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds.
Specification Notes
note 1: All parameters are measured at 5.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure measurements are with
positive pressure applied to Port B.
note 2: Shift is relative to 25C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: THE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN FULL SCALE OUTPUT VOLTAGE AND THE OFFSET VOLTAGE.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

All Sensors

DS-0024 Rev C
3-4

p 408 225 4314

Minimum

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

Amplified Low Pressure Sensors


1 mbar (0.4 In H2O) to 30 In H2O Pressure Sensors

Industrial Temperature Grade


Features
0 to 1 mbar to 0 to 30 In H2O Pressure Ranges
Ratiometric 4V Output
Temperature Compensated (-25C to 85C)
Calibrated Zero and Span

Applications

all sensors

Medical Instrumentation
Environmental Controls
HVAC

General Description
The Amplified line of low pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to change

e www.allsensors.com

in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when
compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration
enhanced structure to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This

f 408 225 2079

series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Pin Size
0.010 x 0.020
(0.25 x 0.50)

pin 2: Common

Pin 1 2 3 4

0.174 to 0.190
(4.4 to 4.8)

pin 4: do not connect

0.42
(10.5)

A
1.08
(27.4)
0.66
(16.0)

pin 3: Voutput
0.21
(5.3)

0.48
(12.2)

pin 1: Vsupply

0.10 Typical
(2.54)

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

0.25
(6.4)

p 408 225 4314

Physical Dimensions

0.55
(14.0)

0.80
(20.3)

NOTES:
1) Dimensions in inches (millimeters)

0.85
(21.6)
1.10
(27.9)

Approvals
MKT

As Is

DATE

With Change

All Sensors

MFG

As Is

DATE

With Change

ENG

As Is

DATE

With Change

QA

DATE

As Is

With Change

DS-0025 Rev B
3-5

Pressure Sensor Ratings

Environmental Specifications

Supply Supply Voltage VS

+4.5 to +5.5 Vdc

Common-mode pressure

-10 to +10 psig

Temperature Ranges
Compensated

250C

Lead Temperature, max


(soldering 2-4 sec.)

-25 to 85 C

Operating

-40 to 125 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

1 MBAR-D-4V-PRIME

Nominal Span

Proof Pressure

Burst Pressure

1 mbar

4V

100 In H2O

200 In H2O

1 INCH-D-4V-PRIME

1 In H2O

4V

100 In H2O

200 In H2O

1 INCH-G-4V-PRIME

0 - 1 In H2O

4V

100 In H2O

200 In H2O

5 INCH-D-4V-PRIME

5 In H2O

4V

200 In H2O

300 In H2O

5 INCH-G-4V-PRIME

0 - 5 In H2O

4V

200 In H2O

300 In H2O

10 INCH-D-4V-PRIME

10 In H2O

4V

200 In H2O

300 In H2O

10 INCH-G-4V-PRIME

0 - 10 In H2O

4V

200 In H2O

300 In H2O

20 INCH-D-4V-PRIME

20 In H2O

4V

300 In H2O

500 In H2O

20 INCH-G-4V-PRIME

0 - 20 In H2O

4V

300 In H2O

500 In H2O

30 INCH-D-4V-PRIME

30 In H2O

4V

500 In H2O

800 In H2O

30 INCH-G-4V-PRIME

0 - 30 In H2O

4V

500 In H2O

800 In H2O

Performance Characteristics for: 1 MBAR-D-4V-PRIME


Minimum

Nominal

Maximum

Units

--

1.0

--

mbar

Output Span, NOTE 5

1.80

2.0

2.20

volt

Offset Voltage @ zero differential pressure

2.00

2.25

2.50

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

120

mvolt

Offset Warm-up Shift, NOTE 3

--

20.0

--

mvolt

Offset Position Sensitivity (1g)

--

40.0

--

mvolt

Offset Long Term Drift (one year)

--

20.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

4.0

%span

Parameter, NOTE 1
Operating Range, differential pressure

Amplified Low Pressure Sensors Industrial grade


3-5

Parameter, note 1

Minimum

Nominal

Maximum

Units

--

1.0

--

H2O

Output Span, note 5

1.90

2.0

2.10

volt

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

60.0

mvolt

Offset Warm-up Shift, NOTE 3

--

10.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

10.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

2.0

%span

Minimum

Nominal

Maximum

Units

--

1.0

--

H2O

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

60.0

mvolt

Offset Warm-up Shift, NOTE 3

--

10.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

10.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

2.0

%span

Minimum

Nominal

Maximum

Units

--

5.0

--

H2O

Output Span, note 5

1.90

2.0

2.10

volt

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

40.0

mvolt

Offset Warm-up Shift, NOTE 3

--

5.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

5.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

1.0

%span

Operating Range, differential pressure

all sensors

Performance Characteristics for 1 INCH-D-4V-PRIME

f 408 225 2079

Operating Range, gage pressure

p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 1 INCH-G-4V-PRIME

Parameter, note 1
Operating Range, differential pressure

All Sensors

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Performance Characteristics for 5 INCH-D-4V-PRIME

DS-0025 Rev B
3-5

Performance Characteristics for: 5 INCH-G-4V-PRIME


Parameter, NOTE 1

Minimum

Nominal

Maximum

Units

--

5.0

--

H2O

Output Span, NOTE 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

40.0

mvolt

Offset Warm-up Shift, NOTE 3

--

5.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

5.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

1.0

%span

Minimum

Nominal

Maximum

Units

--

10.0

--

H2O

Output Span, NOTE 5

1.90

2.0

2.10

volt

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

20.0

mvolt

Offset Warm-up Shift, NOTE 3

--

5.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

5.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

1.0

%span

Minimum

Nominal

Maximum

Units

--

10.0

--

H2O

Output Span, NOTE 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

20.0

mvolt

Offset Warm-up Shift, NOTE 3

--

5.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

5.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

1.0

%span

Operating Range, gage pressure

Performance Characteristics for: 10 INCH-D-4V-PRIME


Parameter, NOTE 1
Operating Range, differential pressure

Performance Characteristics for: 10 INCH-G-4V-PRIME


Parameter, NOTE 1
Operating Range, gage pressure

Amplified Low Pressure Sensors Industrial grade


3-5

Parameter, note 1

Minimum

Nominal

Maximum

Units

--

20.0

--

H2O

Output Span, note 5

1.90

2.0

2.10

volt

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

20.0

mvolt

Offset Warm-up Shift, NOTE 3

--

5.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

5.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

1.0

%span

Minimum

Nominal

Maximum

Units

--

20.0

--

H2O

Output Span, note 5

3.90

4.0

4.1

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

20.0

mvolt

Offset Warm-up Shift, NOTE 3

--

5.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

5.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

1.0

%span

Minimum

Nominal

Maximum

Units

--

30.0

--

H2O

Output Span, note 5

1.90

2.0

2.10

volt

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

20.0

mvolt

Offset Warm-up Shift, NOTE 3

--

5.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

5.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

1.0

%span

Operating Range, differential pressure

all sensors

Performance Characteristics for 20 INCH-D-4V-PRIME

f 408 225 2079

Operating Range, gage pressure

p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 20 INCH-G-4V-PRIME

Parameter, note 1
Operating Range, differential pressure

All Sensors

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Performance Characteristics for 30 INCH-D-4V-PRIME

DS-0025 Rev B
3-5

Performance Characteristics for 30 INCH-G-4V-PRIME


Parameter, NOTE 1

Minimum

Nominal

Maximum

Units

--

30.0

--

H2O

Output Span, NOTE 5

3.9

4.0

4.1

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-25C to 85C), NOTE 2

--

--

20.0

mvolt

Offset Warm-up Shift, NOTE 3

--

5.0

--

mvolt

Offset Position Sensitivity (1g)

--

5.0

--

mvolt

Offset Long Term Drift (one year)

--

5.0

--

mvolt

Linearity, hysteresis error, NOTE 4

--

0.05

0.25

%fs

Span Shift (-25C to 85C), NOTE 2

--

--

1.0

%span

Operating Range, gage pressure

Equivalent Circuit

Specification Notes
NOTE

1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED.
WITH POSITIVE PRESSURE APPLIED TO

2:
3:
NOTE 4:
NOTE 5:
NOTE
NOTE

PORT B.

PRESSURE MEASUREMENTS ARE

SHIFT IS RELATIVE TO 25C.


SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
THE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN FULL SCALE OUTPUT VOLTAGE AND THE VOLTAGE.

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

Amplified Low Pressure Sensors Industrial grade


3-5

Amplified Low Pressure Sensors


1 mbar (0.4 In H2O) to 30 In H2O Pressure Sensors

Military Temperature Grade


Features

all sensors

0 to 1 mbar to 0 to 30 In H2O Pressure Ranges


Ratiometric 4V Output
Temperature Compensated (-40C to 125C)
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
HVAC

e www.allsensors.com

General Description
The Amplified line of low pressure sensors is based upon a proprietary technology to reduce all output offset or
common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteristics.
Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position
sensitivity are all significantly reduced when compared to conventional compensation methods. In addition the
sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output

f 408 225 2079

to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Physical Dimensions

0.25
(6.4)

Pin Size
0.010 x 0.020
(0.25 x 0.50)

0.10 Typical
(2.54)
Pin 1 2 3 4

0.174 to 0.190
(4.4 to 4.8)

pin 1: Vsupply
0.21
(5.3)

pin 2: Common
pin 3: Voutput

A
1.08
(27.4)
0.66
(16.0)

0.48
(12.2)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

0.42
(10.5)

pin 4: do not connect

0.80
(20.3)
0.85
(21.6)
1.10
(27.9)

All Sensors

DS-0026 Rev A
3-6

Pressure Sensor Ratings

Environmental Specifications
+4.5 to +5.5 Vdc

Supply Supply Voltage VS

Temperature Ranges

-10 to +10 psig

Common-mode pressure

250C

Lead Temperature, max


(soldering 2-4 sec.)

Compensated

-40 to 125 C

Operating

-40 to 125 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

1 MBAR-D-4V-MIL

1 mbar

4V

100 In H2O

200 In H2O

1 INCH-D-4V-MIL

1 In H2O

4V

100 In H2O

200 In H2O

1 INCH-G-4V-MIL

0 - 1 In H2O

4V

300 In H2O

200 In H2O

5 INCH-D-4V-MIL

5 In H2O

4V

200 In H2O

300 In H2O

5 INCH-G-4V-MIL

0 - 5 In H2O

4V

200 In H2O

300 In H2O

10 INCH-D-4V-MIL

10 In H2O

4V

200 In H2O

300 In H2O

10 INCH-G-4V-MIL

0 - 10 In H2O

4V

200 In H2O

300 In H2O

20 INCH-D-4V-MIL

20 In H2O

4V

300 In H2O

500 In H2O

20 INCH-G-4V-MIL

0 - 20 In H2O

4V

300 In H2O

500 In H2O

30 INCH-D-4V-MIL

30 In H2O

4V

500 In H2O

800 In H2O

30 INCH-G-4V-MIL

0 - 30 In H2O

4V

500 In H2O

800 In H2O

Performance Characteristics for: 1 MBAR-D-4V-MIL


Parameter, NOTE 1

Minimum

Operating Range, differential pressure


Output Span,

NOTE

Offset Voltage @ zero differential pressure

Nominal
1.0

mbar

2.0

2.20

volt

2.00

2.25

2.50

volt

120

mvolt

20

mvolt

Offset Position Sensitivity (1g)

40

mvolt

Offset Long Term Drift (one year)

20

mvolt

Linearity, hysteresis error, NOTE 4

0.05

NOTE

Units

1.80

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift,

Maximum

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Amplified Low Pressure Sensors Military Grade


3-6

Performance Characteristics for 1 INCH-D-4V-MIL


Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal

Maximum

1.0

Units
H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

60

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

10

mvolt

mvolt

Offset Long Term Drift (one year)

10

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Offset Position Sensitivity (1g)

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Maximum

Units

all sensors

Parameter, note 1

Operating Range, gage pressure

Nominal
1.0

H2O

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

60

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

10

mvolt

Offset Position Sensitivity (1g)

15

mvolt

Offset Long Term Drift (one year)

10

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Maximum

Units

f 408 225 2079

Minimum

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 1 INCH-G-4V-MIL

Performance Characteristics for 5 INCH-D-4V-MIL


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal
5.0

H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

40

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

All Sensors

0.25

%fs

%span

DS-0026 Rev A
3-6

Performance Characteristics for: 5 INCH-G-4V-MIL


Minimum

Parameter, NOTE 1

Nominal

NOTE

Offset Voltage @ zero pressure

Units
H2O

5.0

Operating Range, gage pressure


Output Span,

Maximum

3.90

4.0

4.10

volt

0.15

0.25

0.35

volt

40

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Maximum

Units

Performance Characteristics for: 10 INCH-D-4V-MIL


Parameter, NOTE 1

Minimum

Nominal

Operating Range, differential pressure


Output Span, NOTE 5
Offset Voltage @ zero differential pressure

10.0

H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

20

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Maximum

Units

Performance Characteristics for: 10 INCH-G-4V-MIL


Parameter, NOTE 1

Minimum

Operating Range, gage pressure


Output Span,

NOTE

Offset Voltage @ zero pressure

Nominal
10.0

H2O

3.90

4.0

4.10

volt

0.15

0.25

0.35

volt

20

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Amplified Low Pressure Sensors Military Grade


3-6

Performance Characteristics for 20 INCH-D-4V-MIL


Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal

Maximum

20.0

Units
H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

20

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Maximum

Units

all sensors

Parameter, note 1

Operating Range, gage pressure

Nominal
20.0

H2O

Output Span, note 5

3.90

4.0

4.1

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

20

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Maximum

Units

f 408 225 2079

Minimum

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 20 INCH-G-4V-MIL

Performance Characteristics for 30 INCH-D-4V-MIL


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal
30.0

H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

20

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

All Sensors

0.25

%fs

%span

DS-0026 Rev A
3-6

Performance Characteristics for 30 INCH-G-4V-MIL


Parameter, NOTE 1

Minimum

Operating Range, gage pressure


Output Span,

NOTE

Offset Voltage @ zero pressure

Nominal

Maximum

30.0

Units
H2O

3.9

4.0

4.1

volt

0.15

0.25

0.35

volt

20

mvolt

Offset Temperature Shift (-40C-125C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-40C-125C), NOTE 2

0.25

%fs

%span

Equivalent Circuit

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 500 useconds.

Specification Notes
NOTE

1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS

OTHERWISE SPECIFIED.

PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.

2:
NOTE 3:
NOTE 4:
NOTE 5:

SHIFT IS RELATIVE TO 25C.


SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS
FOR MINUS TO PLUS FULL SCALE PRESSURE.

NOTE

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Amplified Low Pressure Sensors Military Grade


3-6

Amplified Middle Pressure Sensors


Features
0 to 0.3 to 0 to 150 psi Pressure Ranges
Ratiometric 4V Output
Temperature Compensated
Calibrated Zero and Span

Applications

all sensors

Medical Instrumentation
Environmental Instrumentation
HVAC Instrumentation

General Description
The Amplified line of middle pressure sensors are based upon a proprietary package technology to reduce errors. This model provides
induced parasitic stress and strain. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to
provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. Each sensor
is internally compensated using an ASIC compensation technique. This series is intended for use with non-corrosive, non-ionic working

f 408 225 2079

fluids such as air, dry gases and the like.


The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Equivalent Circuit

2.54
0.100
(Typ)

8.74
0.344

1.27
0.050

0.020" x 0.010" Pin


0.30" minimum length

27.43
1.080

5.33
0.210

Port B

10.67
0.420

10.67
0.420

Port A

3.56
0.140
3.18
R0.125

12.19
0.480

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Pin 1 Identifier

3.18
0.125

Port 0.179"/0.189"

CL

p 408 225 4314

Physical Dimensions

pin 1: Vsupply
pin 2: Common

20.32
0.800

13.97
0.550

pin 3: Voutput

21.59
0.850

pin 4: do not connect


Approvals
MKT DATE

As Is

With Change

MFG DATE

As Is

ENG DATE

All Sensors

With Change

TITLE:

pin, No Port Cut,


As A-Package,
Is Barb, Flat4With
No
LeadsChange

SIZE

FILE NAME

DS-0028 RevAD

All Sensors
5

e www.allsensors.com

a ratiometric 4-volt output with superior output characteristics. The sensor housing has been designed specifically to reduce package

QA DATE

As Is

With Change

A4AAF Rev B
1

3-7

Pressure Sensor Ratings

Environmental Specifications
+4.5 to +5.5 Vdc

Supply Voltage, Vs

-10 to +10 psig

Common-mode pressure

250C

Lead Temperature, max


(soldering 2-4 sec.)

Temperature Ranges
Compensated

5 to 50 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

0.3 PSI-D-4V

0.3 PSI

2 V

5 PSI

10 PSI

0.3 PSI-G-4V

0 - 0.3 PSI

4V

5 PSI

10 PSI

1 PSI-D-4V

1 PSI

2 V

5 PSI

10 PSI

1 PSI-G-4V

0 - 1 PSI

4V

5 PSI

10 PSI

2.5 PSI-D-4V

2.5 PSI

2 V

10 PSI

20 PSI

2.5 PSI-G-4V

0 - 2.5 PSI

4V

10 PSI

20 PSI

5 PSI-D-4V

5 PSI

2 V

15 PSI

30 PSI

5 PSI-G-4V

0 - 5 PSI

4V

15 PSI

30 PSI

15 PSI-A-4V

0 - 15 PSIA

4V

45 PSI

60 PSI

15 PSI-D-4V

15 PSI

2 V

45 PSI

60 PSI

15 PSI-G-4V

0 - 15 PSI

4V

45 PSI

60 PSI

30 PSI-A-4V

0 - 30 PSIA

4V

60 PSI

60 PSI

30 PSI-D-4V

30 PSI

2 V

60 PSI

60 PSI

30 PSI-G-4V

0 - 30 PSI

4V

60 PSI

100 PSI

100 PSI-A-4V

0 - 100 PSI

4V

150 PSI

150 PSI

100 PSI-D-4V

100 PSI

2 V

150 PSI

150 PSI

100 PSI-G-4V

0 - 100 PSI

4V

150 PSI

150 PSI

150 PSI-D-4V

150 PSI

2 V

200 PSI

200 PSI

150 PSI-G-4V

0 - 150 PSI

4V

200 PSI

200 PSI

600 - 1100 mbarA

4V

45 PSI

60 PSI

BARO-A-4V

Performance Characteristics for 0.3 PSI-D-4V


Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

--

--

40.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

2.0

%FSS

Parameter, note 1

Amplified Output Medium Pressure Sensor


3-7

Performance Characteristics for 0.3 PSI-G-4V


Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

40.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

2.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

--

--

40.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

40.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Parameter, note 1

e www.allsensors.com
f 408 225 2079

Parameter, note 1

all sensors

Performance Characteristics for 1 PSI-D-4V

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for: 1 PSI-G-4V

Performance Characteristics for 2.5 PSI-D-4V


Parameter, note 1

All Sensors

DS-0028 Rev D
3-7

Performance Characteristics for: 2.5 PSI-G-4V


Parameter, note 1

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero absolute pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Performance Characteristics for: 5 PSI-D-4V


Parameter, note 1

Performance Characteristics for: 5 PSI-G-4V


Parameter, note 1

Performance Characteristics for 15 PSI-A-4V


Parameter, note 1

Amplified Output Medium Pressure Sensor


3-7

Parameter, note 1

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero absolute pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

all sensors

Performance Characteristics for 15 PSI-D-4V

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 15 PSI-G-4V

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for 30 PSI-A-4V

Performance Characteristics for 30 PSI-D-4V


Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Parameter, note 1

All Sensors

DS-0028 Rev D
3-7

Performance Characteristics for 30 PSI-G-4V


Parameter, note 1

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero absolute pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Performance Characteristics for 100 PSI-A-4V


Parameter, note 1

Performance Characteristics for 100 PSI-D-4V


Parameter, note 1

Performance Characteristics for 100 PSI-G-4V


Parameter, note 1

Amplified Output Medium Pressure Sensor


3-7

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Span, note 4 (FSS)

3.90

4.0

4.10

Offset Voltage @ zero gage pressure

0.15

0.25

0.35

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

Minimum

Nominal

Maximum

Units

Output Voltage @ 1,100 mbar

4.20

4.25

4.30

Output Voltage @ 600 mbar

0.20

0.25

0.30

Offset Temperature Shift, note 2

--

--

20.0

mV

Linearity, hysteresis error, note 3

--

0.05

0.25

%FSS

Span Temperature Shift, note 2

--

--

1.0

%FSS

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 150 PSI-G-4V

Parameter, note 1

p 408 225 4314

Performance Characteristics for BARO-A-4V

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds.
Specification Notes
1: All parameters are measured at 5.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure measurements are with
Port B. Absolute devices require pressure to be applied to port A.
note 2: Shift is relative to 25C over the compensated temperature range.
note 3: Measured at one-half full scale rated pressure using best straight line curve fit.
note 4: The span is the algebraic difference between full scale output voltage and the offset voltage.
note

positive pressure applied to

All Sensors

DS-0028 Rev D
3-7

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

all sensors

Performance Characteristics for 150 PSI-D-4V

Amplified Middle Pressure Sensors


Industrial Temperature Grade
Features
0 to 0.3 psi to 0 to 100 psi Pressure Ranges
Ratiometric 4V Output
Temperature Compensated (-25C to 85C)
Calibrated Zero and Span

Applications

all sensors

Medical Instrumentation
Environmental Controls
HVAC

General Description
The Amplified line of middle pressure sensors is based upon a proprietary package technology to reduce errors. This model provides
induced parasitic stress and strain. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to
provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. Each sensor
is internally compensated using an ASIC compensation technique. This series is intended for use with non-corrosive, non-ionic working

f 408 225 2079

fluids such as air, dry gases and the like.

p 408 225 4314

The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Physical Dimensions

2.54
0.100
(Typ)

8.74
0.344

1.27
0.050

0.020" x 0.010" Pin


0.30" minimum length

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Pin 1 Identifier

3.18
0.125

Port B

3.56
0.140
3.18
R0.125

27.43
1.080

5.33
0.210

10.67
0.420

Port A

10.67
0.420

Port 0.179"/0.189"

CL

pin 1: Vs
pin 2: Gnd

12.19
0.480

20.32
0.800

13.97
0.550

pin 3: Vout

21.59
0.850

pin 4: do not connect

Approvals
MKT DATE

As Is

With Change

e www.allsensors.com

a ratiometric 4-volt output with superior output characteristics. The sensor housing has been designed specifically to reduce package

MFG DATE

As Is

All Sensors

With Change

ENG DATE

As Is

With Change

QA DATE

As Is

With Change

DS-0029 Rev C
3-8

Pressure Sensor Ratings

Environmental Specifications

Supply Supply Voltage VS

+4.5 to +5.5 Vdc

Common-mode pressure

-10 to +10 psig

Temperature Ranges
Compensated

250C

Lead Temperature, max


(soldering 2-4 sec.)

-25 to 85 C

Operating

-40 to 125 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

0.3 PSI-D-4V-PRIME

0.3 PSI

4V

5 PSI

10 PSI

0.3 PSI-G-4V-PRIME

0 - 0.3 PSI

4V

5 PSI

10 PSI

1 PSI-D-4V-PRIME

1 PSI

4V

5 PSI

10 PSI

1 PSI-G-4V-PRIME

0 - 1 PSI

4V

5 PSI

10 PSI

5 PSI-D-4V-PRIME

5 PSI

4V

15 PSI

30 PSI

5 PSI-G-4V-PRIME

0 - 5 PSI

4V

15 PSI

30 PSI

15 PSI-A-4V-PRIME

0 - 15 PSIA

4V

45 PSI

60 PSI

15 PSI-D-4V-PRIME

15 PSI

4V

45 PSI

60 PSI

15 PSI-G-4V-PRIME

0 - 15 PSI

4V

45 PSI

60 PSI

30 PSI-A-4V-PRIME

0 - 30 PSIA

4V

90 PSI

150 PSI

30 PSI-D-4V-PRIME

30 PSI

4V

90 PSI

150 PSI

30 PSI-G-4V-PRIME

0 - 30 PSI

4V

90 PSI

150 PSI

100 PSI-A-4V-PRIME

0 - 100 PSIA

4V

150 PSI

150 PSI

100 PSI-D-4V-PRIME

100 PSI

4V

150 PSI

150 PSI

100 PSI-G-4V-PRIME

0 - 100 PSI

4V

150 PSI

150 PSI

Performance Characteristics for 0.3 PSI-D-4V-PRIME


Minimum

Nominal

Maximum

Units

--

0.3

--

PSI

1.90

2.0

2.10

2.15

2.25

2.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

40

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Parameter, note 1
Operating Range, differential pressure
Output Span, note 4
Offset Voltage @ zero differential pressure

Amplified Middle Pressure Sensors Industrial Grade


3-8

Parameter, note 1

Minimum

Nominal

Maximum

Units

--

0.3

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

40

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

1.0

--

PSI

1.90

2.0

2.10

2.15

2.25

2.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

40

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

1.0

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

40

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

5.0

--

PSI

1.90

2.0

2.10

2.15

2.25

2.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Operating Range, gage pressure

all sensors

Performance Characteristics for 0.3 PSI-G-4V-PRIME

Operating Range, differential pressure


Output Span, note 4
Offset Voltage @ zero differential pressure

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 1 PSI-D-4V-PRIME

Operating Range, gage pressure

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for: 1 PSI-G-4V-PRIME

Performance Characteristics for: 5 PSI-D-4V-PRIME


Parameter, note 1
Operating Range, differential pressure
Output Span, note 4
Offset Voltage @ zero differential pressure

All Sensors

DS-0029 Rev C
3-8

Performance Characteristics for: 5 PSI-G-4V-PRIME


Parameter, note 1

Minimum

Nominal

Maximum

Units

--

5.0

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

15.0

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

15.0

--

PSI

1.90

2.0

2.10

2.15

2.25

2.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

15.0

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Operating Range, gage pressure

Performance Characteristics for 15 PSI-A-4V-PRIME


Parameter, note 1
Operating Range, absolute pressure

Performance Characteristics for 15 PSI-D-4V-PRIME


Parameter, note 1
Operating Range, differential pressure
Output Span, note 4
Offset Voltage @ zero differential pressure

Performance Characteristics for 15 PSI-G-4V-PRIME


Parameter, note 1
Operating Range, gage pressure

Amplified Middle Pressure Sensors Industrial Grade


3-8

Parameter, note 1

Minimum

Nominal

Maximum

Units

--

30.0

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Operating Range, absolute pressure

all sensors

Performance Characteristics for 30 PSI-A-4V-PRIME

Minimum

Nominal

Maximum

Units

--

30.0

--

PSI

1.90

2.0

2.10

2.15

2.25

2.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

30.0

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C, note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

100.0

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Operating Range, differential pressure


Output Span, note 4
Offset Voltage @ zero differential pressure

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 30 PSI-D-4V-PRIME

Operating Range, gage pressure

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for 30 PSI-G-4V-PRIME

Performance Characteristics for 100 PSI-A-4V-PRIME


Parameter, note 1
Operating Range, absolute pressure

All Sensors

DS-0029 Rev C
3-8

Performance Characteristics for 100 PSI-D-4V-PRIME


Parameter, note 1

Minimum

Nominal

Maximum

Units

--

100

--

PSI

1.90

2.0

2.10

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Minimum

Nominal

Maximum

Units

--

100

--

PSI

Output Span, note 4

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (-25C to 85C), note 2

--

--

20

mV

Linearity, hysteresis error, note 3

--

--

0.5

%FSS

Span Shift (-25C to 85C), note 2

--

--

%FSS

Operating Range, differential pressure


Output Span, note 4
Offset Voltage @ zero differential pressure

Performance Characteristics for 100 PSI-G-4V-PRIME


Parameter, note 1
Operating Range, gage pressure

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds.
Specification Notes
1: All parameters are measured at 5.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure measurements are with
Port B. Absolute devices require pressure to be applied to port A.
note 2: Shift is relative to 25C.
note 3: Measured at one-half full scale rated pressure using best straight line curve fit.
note 4: The span is the algebraic difference between full scale output voltage and the offset voltage
note

positive pressure applied to

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

Equivalent Circuit
Vs

Vout

+
Gnd

Amplified Middle Pressure Sensors Industrial Grade


3-8

Amplified Middle Pressure Sensors


Military Temperature Grade

0.3 psi to 15 psi Pressure Sensors

Features

all sensors

0 to 0.3 psi to 0 to 15 psi Pressure Ranges


Ratiometric 4V Output
Temperature Compensated (-40C to 125C)
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
HVAC

e www.allsensors.com

General Description
The Amplified line of middle pressure sensors is based upon a proprietary package technology to reduce errors.
This model provides a ratiometric 4-volt output with superior output characteristics. The sensor housing has been
designed specifically to reduce package induced parasitic stress and strain. In addition the sensor utilizes a
silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured

f 408 225 2079

pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. Each sensor is internally compensated using an ASIC compensation technique. This series is
intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Physical Dimensions

0.25
(6.4)

Pin Size
0.010 x 0.020
(0.25 x 0.50)

0.10 Typical
(2.54)
Pin 1 2 3 4

0.174 to 0.190
(4.4 to 4.8)

pin 1: Vsupply
0.21
(5.3)

pin 2: Common
pin 3: Voutput

A
1.08
(27.4)
0.66
(16.0)

0.48
(12.2)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

0.42
(10.5)

pin 4: do not connect

0.80
(20.3)
0.85
(21.6)
1.10
(27.9)

All Sensors

DS-0031 Rev A
3-9

Pressure Sensor Ratings

Environmental Specifications
+4.5 to +5.5 Vdc

Supply Supply Voltage VS

Temperature Ranges

-10 to +10 psig

Common-mode pressure

250C

Lead Temperature, max


(soldering 2-4 sec.)

Compensated

-40 to 125 C

Operating

-40 to 125 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

0.3 PSI-D-4V-MIL

0.3 PSI

4V

5 PSI

10 PSI

0.3 PSI-G-4V-MIL

0 - 0.3 PSI

4V

5 PSI

10 PSI

1 PSI-D-4V-MIL

1 PSI

4V

5 PSI

10 PSI

1 PSI-G-4V-MIL

0 - 1 PSI

4V

5 PSI

10 PSI

5 PSI-D-4V-MIL

5 PSI

4V

15 PSI

30 PSI

5 PSI-G-4V-MIL

0 - 5 PSI

4V

15 PSI

30 PSI

15 PSI-A-4V-MIL

0 - 15 PSIA

4V

45 PSI

60 PSI

15 PSI-D-4V-MIL

15 PSI

4V

45 PSI

60 PSI

15 PSI-G-4V-MIL

0 - 15 PSIG

4V

45 PSI

60 PSI

Performance Characteristics for 0.3 PSI-D-4V-MIL


Parameter, note 1

Minimum

Operating Range, differential pressure

Nominal

Maximum

0.3

Units
PSI

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

Offset Temperature Shift (-40C to 125C), note 2

40

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Output Span, note 5


Offset Voltage @ zero differential pressure

Span Shift (-40C to 125C), note 2

Performance Characteristics for 0.3 PSI-G-4V-MIL


Parameter, note 1

Minimum

Operating Range, gage pressure

Nominal
0.3

PSI

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-40C to 125C), note 2

40

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Span Shift (-40C to 125C), note 2

Amplified Middle Pressure Sensors Military Grade


3-9

Performance Characteristics for 1 PSI-D-4V-MIL


Minimum

Maximum

1.0

Operating Range, differential pressure


Output Span, note 5

Nominal

Units
PSI

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

Offset Temperature Shift (-40C to 125C), note 2

40

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Offset Voltage @ zero differential pressure

Span Shift (-40C to 125C), note 2

all sensors

Parameter, note 1

Minimum

Operating Range, gage pressure

1.0

PSI

3.90

4.0

4.10

volt

0.15

0.25

0.35

volt

Offset Temperature Shift (-40C to 125C), note 2

40

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Output Span,

NOTE

Nominal

Offset Voltage @ zero pressure

Span Shift (-40C to 125C), note 2

f 408 225 2079

Parameter, NOTE 1

e www.allsensors.com

Performance Characteristics for: 1 PSI-G-4V-MIL

Performance Characteristics for: 5 PSI-D-4V-MIL


Minimum

Output Span, NOTE 5


Offset Voltage @ zero differential pressure

Nominal

PSI

5.0
1.90

2.0

2.10

2.15

2.25

volt

2.35

volt

Offset Temperature Shift (-40C to 125C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Span Shift (-40C to 125C), note 2

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Parameter, NOTE 1
Operating Range, differential pressure

Performance Characteristics for: 5 PSI-G-4V-MIL


Parameter, NOTE 1

Minimum

Operating Range, gage pressure

Nominal
5.0

PSI

Output Span, NOTE 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-40C to 125C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Span Shift (-40C to 125C), note 2

All Sensors

DS-0031 Rev A
3-9

Performance Characteristics for 15 PSI-A-4V-MIL


Parameter, note 1

Minimum

Operating Range, absolute pressure

Nominal

Maximum

Units
PSI

15.0

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-40C to 125C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Span Shift (-40C to 125C), note 2

Performance Characteristics for 15 PSI-D-4V-MIL


Parameter, note 1

Minimum

Nominal
15.0

Operating Range, differential pressure

PSI

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

Offset Temperature Shift (-40C to 125C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Output Span, note 5


Offset Voltage @ zero differential pressure

Span Shift (-40C to 125C), note 2

Performance Characteristics for 15 PSI-G-4V-MIL


Parameter, note 1

Minimum

Operating Range, gage pressure

Nominal
15.0

PSI

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (-40C to 125C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Span Shift (-40C to 125C), note 2

Equivalent Circuit
Pressure Response: for any pressure applied the
response time to get to 90% of pressure applied is
typically less than 500 useconds.

Specification Notes
1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS
FOR MINUS TO PLUS FULL SCALE PRESSURE.
NOTE

OTHERWISE SPECIFIED.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Amplified Middle Pressure Sensors Military Grade


3-9

ASCX Series Compatible Pressure Sensors


COMPATIBLE TO SENSYM ASCX SERIES

Features
5 Vdc Supply
High Level Voltage Output
Ratiometric 4.5 V Span
Temperature Compensated
Calibrated Zero and Span
MULTIPLE Pressure Ranges

all sensors

Applications

General Description

e www.allsensors.com

Medical Instrumentation
Environmental Instrumentation
HVAC Instrumentation
Pneumatic Controls

The Amplified line of middle pressure sensors is based upon a proprietary package technology to reduce errors. This model provides a
In addition the sensor utilizes a silicon, micromachined, stress

concentration enhanced structure to provide a very linear output to measured pressure.


These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range.
Each sensor is internally compensated using an ASIC compensation technique. This series is intended for use with non-

p 408 225 4314

corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Physical Dimensions
0.25
(6.4)

Equivalent Circuit

Pin Size
0.010 x 0.020
(0.25 x 0.50)
Pin 1 2 3 4

0.174 to 0.190
(4.4 to 4.8)

0.21
(5.3)

A
1.08
(27.4)
0.66
(16.0)

0.48
(12.2)

Pin 1: Vsupply

0.10 Typical
(2.54)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

Pin 2: Voutput

0.42
(10.5)

Pin 3: Common

0.80
(20.3)
0.85
(21.6)

Pin
Pin
Pin
Pin

1: Vsupply
2: Voutput
3: Common
4: Do not connect

1.10
(27.9)

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.

All Sensors

06/20/2006

ASCX Series Compatible Rev A

DS-0023 Rev A

3-10

a 16035 Vineyard Blvd., Morgan Hill, CA 95037

reduce package induced parasitic stress and strain.

f 408 225 2079

ratiometric 4.5-volt output span with superior output characteristics. The sensor housing has been designed specifically to

Maximum Ratings

Environmental Specifications

Supply Voltage, Vs

+4.5 to +5.5 Vdc

Lead Soldering Temperature (2-4 sec.)


Quiescent Current

(6)

Compensated Temperature

0 to 70C

250 C

Operating Temperature

-25 to 105C

7.5 mA

Storage Temperature

-55 to 125C

Humidity Limits (non condensing)

0 to 95% RH

Pressure Ranges
Part Number

Operating Pressure

Proof Pressure

Burst Pressure

1 PSI-D-4V-ASCX

0 - 1 PSID

5 PSI

10 PSI

5 PSI-D-4V-ASCX

0 - 5 PSID

15 PSI

30 PSI

15 PSI-D-4V-ASCX

0 - 15 PSID

45 PSI

75 PSI

15 PSI-A-4V-ASCX

0 - 15 PSIA

45 PSI

75 PSI

30 PSI-D-4V-ASCX

0 - 30 PSID

100 PSI

150 PSI

30 PSI-A-4V-ASCX

0 - 30 PSIA

100 PSI

150 PSI

100 PSI-D-4V-ASCX

0 - 100 PSID

150 PSI

150 PSI

100 PSI-A-4V-ASCX

0 - 100 PSIA

150 PSI

150 PSI

Performance Characteristics for 1/5 PSI-D-4V-ASCX


Parameter

(1)

Output Span

(5)

Span Shift (0 C to 70 C)
Offset Voltage @ zero pressure
Offset Shift (0 C to 70 C)

(2)

Combined Linearity and Hysteresis Error

(4)

(7)

Repeatability

Response Time

(8)

Minimum

Nominal

Maximum

Units

4.43

4.50

4.57

Volt

0.2

1.5

%Span

0.18

0.25

0.32

Volt

0.5

1.5

%Span

0.1

0.5

%Span

0.2

0.5

% Span

100

uSec

Performance Characteristics for 15/30/100 PSI-x-4V-ASCX


Parameter

(1)

Output Span

(5)

Span Shift (0 C to 70 C)
Offset Voltage @ zero pressure
Offset Shift (0 C to 70 C)

(2)

Combined Linearity and Hysteresis Error


Repeatability

(7)

Response Time

(8)

(4)

Minimum

Nominal

Maximum

Units

4.45

4.50

4.55

Volt

0.2

1.0

%Span

0.20

0.25

0.30

Volt

0.5

1.0

%Span

0.1

0.5

%Span

0.2

0.5

% Span

100

uSec

Specification Notes
1) ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED .
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO P ORT B. ABSOLUTE DEVICES ARE WITH PRESSURE APPLIED TO PORT A.
2) SHIFT IS RELATIVE TO 25C.
4) MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT FOR THE SPAN INDICATED.
5) THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.75 VOLTS FOR MINUS TO
PLUS FULL SCALE PRESSURE .
6) PARAMETER IS COMPUTED AS MAXIMUM FOR DESIGN REFERENCE AND IS NOT TESTED.
7) MAXIMUM DIFERENCE IN OUTPUT AT ANY PRESSURE WITHIN THE OPERATING PRESSURE RANGE AND COMPENSATED TEMPERATURE RANGE AFTER: A) 1000
TEMPERATURE CYCLES AND B) 1.0 MILLION PRESSURE CYCLES .
8) RESPONSE TIME FOR A ZERO TO FULL SCALE PRESSURE STEP CHANGE, 10% TO 90% RISE TIME.

ASCX Series Compatible Rev A

DS-0023 Rev A

3-10

Miniature Amplified Low Pressure Sensors


Low Pressure (0.5 H2O to 30 H2O) Sensors

Features
0 to 0.5 H2O to 0 to 30 H2O Pressure Ranges
Temperature Compensated
Calibrated Zero and Span

General Description
The Miniature Amplified Output pressure sensor is based upon a proprietary technology to reduce all output offset or common
mode errors. This model provides a calibrated amplified output with superior output offset characteristics. Output offset errors
due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly
reduced when compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress
concentration enhanced structure to provide a very linear output to measured pressure.

These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This

f 408 225 2079

series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage between 4.5 and 5.5

7.17
0.282
1.78
0.070

2.12
0.084

Vs

12.70
0.500

0.64
0.025

2.09
0.082

10.79
0.425

2.12
0.084

Port B

2.04
0.080
2.14
0.084

2.73
0.108

[9.65]
0.380 (nom)

D1 version, D2 version, G verison

Gnd

Port A

0.51
0.020

0.25
0.010

NOTES
1) Dimensions are in inches [mm].
2) For suggested pad layout, see drawing: PAD-01

Vout

6.45
0.254

9.81
0.386

1.01
0.040

10.79
0.425

15.75
0.620

1.16
0.046

2.54
0.100

Pin 1 2 3 4

Pin 1: Vs
Pin 2: Gnd
Pin 3: Vout
Pin 4: Do Not Connect

Approvals
MKT

As Is

All Sensors

DATE

With Change

MFG

As Is

DATE

ENG

With Change

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0101 Rev B

3-11

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Product Label Placement on Backside Lid

p 408 225 4314

Equivalent Circuit

Physical Dimensions

e www.allsensors.com all

Medical Instrumentation
Environmental Controls
HVAC

sensors

Applications

Pressure Sensor Characteristics Maximum Ratings


+4.5 to +5.5 Vdc

Supply Voltage, Vs

10 psig

Common-mode pressure

250C

Lead Temperature
(soldering 2-4 sec.)

Environmental Specifications
Temperature Ranges
Compensated

5 to 50 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

0.5 inH2O

4V

100 inH2O

200 inH2O

1 INCH-Dx-4V-MINI

1 inH2O

4V

100 inH2O

200 inH2O

1 INCH-G-4V-MINI

0 - 1 inH2O

4V

100 inH2O

200 inH2O

5 INCH-Dx-4V-MINI

5 inH2O

4V

200 inH2O

300 inH2O

5 INCH-G-4V-MINI

0 - 5 inH2O

4V

200 inH2O

300 inH2O

10 INCH-Dx-4V-MINI

10 inH2O

4V

200 inH2O

300 inH2O

10 INCH-G-4V-MINI

0 - 10 inH2O

4V

200 inH2O

300 inH2O

20 INCH-Dx-4V-MINI

20 inH2O

4V

300 inH2O

500 inH2O

20 INCH-G-4V-MINI

0 - 20 inH2O

4V

300 inH2O

500 inH2O

30 INCH-Dx-4V-MINI

30 inH2O

4V

500 inH2O

800 inH2O

30 INCH-G-4V-MINI

0 - 30 inH2O

4V

500 inH2O

800 inH2O

0.5 INCH-Dx-4V-MINI

For differential pressure D1 is the package with two pressure ports the same side, D2 has two ports the opposite sides.

Performance Characteristics for 0.5 INCH-Dx-4V-MINI


Parameter, note 1

Minimum

Nominal

Maximum

Units

0.5

inH2O

Output Span, note 5

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift (5C-50C), note 2

120

mV

Offset Warm-up Shift, note 3

10

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

10

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Shift (5C-50C), note 2

%FSS

Operating Range, differential pressure

Miniature Amplified Low Pressure Sensors


3-11

Performance Characteristics for 1 INCH-Dx-4V-MINI


Minimum

Nominal

Maximum

Units

1.0

inH2O

Output Span, note 5

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift (5C-50C), note 2

60

mV

Offset Warm-up Shift, note 3

10

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

10

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Shift (5C-50C), note 2

%FSS

Minimum

Nominal

Maximum

Units

1.0

inH2O

Output Span, note 5

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (5C-50C), note 2

60

mV

Offset Warm-up Shift, note 3

10

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

10

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Shift (5C-50C), note 2

%FSS

Minimum

Nominal

Maximum

Units

5.0

inH2O

Output Span, note 5

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift (5C-50C), note 2

40

mV

Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Shift (5C-50C), note 2

%FSS

Operating Range, differential pressure

sensors

Parameter, note 1

f 408 225 2079

Operating Range, gage pressure

p 408 225 4314

Parameter, note 1

e www.allsensors.com all

Performance Characteristics for 1 INCH-G-4V-MINI

Parameter, note 1
Operating Range, differential pressure

All Sensors

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Performance Characteristics for 5 INCH-Dx-4V-MINI

DS-0101 Rev B

3-11

Performance Characteristics for: 5 INCH-G-4V-MINI


Parameter, NOTE 1

Minimum

Nominal

Maximum

Units

5.0

inH2O

Output Span, NOTE 5

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (5C-50C), NOTE 2

40

mV

Offset Warm-up Shift, NOTE 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, NOTE 4

0.05

0.25

%FSS

Span Shift (5C-50C), NOTE 2

%FSS

Minimum

Nominal

Maximum

Units

10.0

inH2O

Output Span, NOTE 5

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift (5C-50C), NOTE 2

20

mV

Offset Warm-up Shift, NOTE 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, NOTE 4

0.05

0.25

%FSS

Span Shift (5C-50C), NOTE 2

%FSS

Minimum

Nominal

Maximum

Units

10.0

inH2O

Output Span, NOTE 5

3.90

4.0

4.10

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (5C-50C), NOTE 2

20

mV

Offset Warm-up Shift, NOTE 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, NOTE 4

0.05

0.25

%FSS

Span Shift (5C-50C), NOTE 2

%FSS

Operating Range, gage pressure

Performance Characteristics for: 10 INCH-Dx-4V-MINI


Parameter, NOTE 1
Operating Range, differential pressure

Performance Characteristics for: 10 INCH-G-4V-MINI


Parameter, NOTE 1
Operating Range, gage pressure

Miniature Amplified Low Pressure Sensors


3-11

Minimum

Nominal

Maximum

Units

20.0

inH2O

Output Span, note 5

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift (5C-50C), note 2

20

mV

Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Shift (5C-50C), note 2

%FSS

Minimum

Nominal

Maximum

Units

20.0

inH2O

Output Span, note 5

3.90

4.0

4.1

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (5C-50C), note 2

20

mV

Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Shift (5C-50C), note 2

%FSS

Minimum

Nominal

Maximum

Units

30.0

inH2O

Output Span, note 5

1.90

2.0

2.10

Offset Voltage @ zero differential pressure

2.15

2.25

2.35

Offset Temperature Shift (5C-50C), note 2

20

mV

Offset Warm-up Shift, note 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, note 4

0.05

0.25

%FSS

Span Shift (5C-50C), note 2

%FSS

Operating Range, differential pressure

e www.allsensors.com all

Parameter, note 1

sensors

Performance Characteristics for 20 INCH-Dx-4V-MINI

Operating Range, gage pressure

p 408 225 4314

Parameter, note 1

f 408 225 2079

Performance Characteristics for 20 INCH-G-4V-MINI

Parameter, note 1
Operating Range, differential pressure

All Sensors

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Performance Characteristics for 30 INCH-Dx-4V-MINI

DS-0101 Rev B

3-11

Performance Characteristics for 30 INCH-G-4V-MINI


Parameter, NOTE 1

Minimum

Nominal

Maximum

Units

30.0

inH2O

Output Span, NOTE 5

3.9

4.0

4.1

Offset Voltage @ zero pressure

0.15

0.25

0.35

Offset Temperature Shift (5C-50C), NOTE 2

20

mV

Offset Warm-up Shift, NOTE 3

mV

Offset Position Sensitivity (1g)

mV

Offset Long Term Drift (one year)

mV

Linearity, hysteresis error, NOTE 4

0.05

0.25

%FSS

Span Shift (5C-50C), NOTE 2

%FSS

Operating Range, gage pressure

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than
500 useconds.
Specification Notes
1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED.
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE B-PORT.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS FOR MINUS TO PLUS
FULL SCALE PRESSURE.
NOTE

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Miniature Amplified Low Pressure Sensors


3-11

MiniatureAmplifiedLowPressureSensors
Low Pressure (1 H2O to 30 H2O) Sensors

PRIME GRADE

Features

all sensors

0 to 1 H2O to 0 to 30 H2O Pressure Ranges


Matched pressure port volumes
Temperature Compensated ( -25 to 85 C)
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
HVAC

General Description

e www.allsensors.com

The Miniature Amplified Output pressure sensors is based upon a proprietary technology to reduce all output
offset or common mode errors. This model provides a calibrated amplified output with superior output offset
characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time
period, and position sensitivity are all significantly reduced when compared to conventional compensation
methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to
provide a very linear output to measured pressure.

f 408 225 2079

These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage between

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

4.5 and 5.5 volts.

Physical Dimensions
0.30
(7.6)

0.50
(12.7)
B-port
A-port

0.380

0.62
(15.7)

Pin 1 2 3 4
0.10
Typical
(2.54)

0.080 O.D.
(2.00)

Equivalent Circuit

All Sensors

D1 version

D2 version

or G verison

DS-0102 Rev A
3-12

Pressure Sensor Characteristics Maximum Ratings


+4.5 to +5.5

Supply Supply Voltage VS

Temperature Ranges

Vdc

Common-mode pressure

Compensated

10 psig

Lead Temperature
(soldering 2-4 sec.)

Environmental Specifications

250C

-25 to 85 C

Operating

-40 to 125 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

1 INCH-Dx-P4V-MINI

1 In H2O

4V

100 In H2O

200 In H2O

1 INCH-G-P4V-MINI

0 - 1 In H2O

4V

300 In H2O

200 In H2O

5 INCH-Dx-P4V-MINI

5 In H2O

4V

200 In H2O

300 In H2O

5 INCH-G-P4V-MINI

0 - 5 In H2O

4V

200 In H2O

300 In H2O

10 INCH-Dx-P4V-MINI

10 In H2O

4V

200 In H2O

300 In H2O

10 INCH-G-P4V-MINI

0 - 10 In H2O

4V

200 In H2O

300 In H2O

20 INCH-Dx-P4V-MINI

20 In H2O

4V

300 In H2O

500 In H2O

20 INCH-G-P4V-MINI

0 - 20 In H2O

4V

300 In H2O

500 In H2O

30 INCH-Dx-P4V-MINI

30 In H2O

4V

500 In H2O

800 In H2O

30 INCH-G-P4V-MINI

0 - 30 In H2O

4V

500 In H2O

800 In H2O

60 INCH-Dx-P4V-MINI

60 In H2O

4V

500 In H2O

800 In H2O

For differential pressure D1 is the package with two pressure ports the same side, D2 has two ports the opposite sides.

Equivalent Circuit

MiniatureAmplifiedLowPressureSensors
3-12

Performance Characteristics for 1 INCH-Dx-P4V-MINI


Minimum

Offset Voltage @ zero differential pressure

Maximum

1.0

Operating Range, differential pressure


Output Span, note 5

Nominal

Units
H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

60

mvolt

Offset Temperature Shift (-25C-85C), note 2


Offset Warm-up Shift, note 3

10

mvolt

mvolt

Offset Long Term Drift (one year)

10

mvolt

Linearity, hysteresis error, note 4

0.05

Offset Position Sensitivity (1g)

Span Shift (-25C-85C), note 2

0.25

%fs

%span

Maximum

Units

all sensors

Parameter, note 1

Nominal

H2O

1.0

Operating Range, gage pressure


Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

60

mvolt

Offset Temperature Shift (-25C-85C), note 2


Offset Warm-up Shift, note 3

10

mvolt

Offset Position Sensitivity (1g)

15

mvolt

Offset Long Term Drift (one year)

10

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (5C-50C), note 2

0.25

%fs

%span

Maximum

Units

f 408 225 2079

Minimum

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 1 INCH-G-P4V-MINI

Performance Characteristics for 5 INCH-Dx-P4V-MINI


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal
5.0

H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

40

mvolt

Offset Temperature Shift (-25C-85C), note 2


Offset Warm-up Shift, note 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (-25C-85C), note 2

All Sensors

0.25

%fs

%span

DS-0102 Rev A
3-12

Performance Characteristics for: 5 INCH-G-P4V-MINI


Parameter, NOTE 1

Minimum

Operating Range, gage pressure

Nominal

Maximum

Units
mbar

5.0

Output Span, NOTE 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

40

mvolt

Offset Temperature Shift (-25C-85C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-25C-85C), NOTE 2

0.25

%fs

%span

Maximum

Units

Performance Characteristics for: 10 INCH-Dx-P4V-MINI


Parameter, NOTE 1

Minimum

Operating Range, differential pressure


Output Span, NOTE 5
Offset Voltage @ zero differential pressure

Nominal
10.0

mbar

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

20

mvolt

Offset Temperature Shift (-25C-85C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-25C-85C), NOTE 2

0.25

%fs

%span

Maximum

Units

Performance Characteristics for: 10 INCH-G-P4V-MINI


Parameter, NOTE 1

Minimum

Operating Range, gage pressure

Nominal
10.0

mbar

Output Span, NOTE 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

20

mvolt

Offset Temperature Shift (-25C-85C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

Span Shift (-25C-85C), NOTE 2

0.25

%fs

%span

MiniatureAmplifiedLowPressureSensors
3-12

Performance Characteristics for 20 INCH-Dx-P4V-MINI

Offset Voltage @ zero differential pressure

Maximum

20.0

Operating Range, differential pressure


Output Span, note 5

Nominal

Units
H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

20

mvolt

Offset Temperature Shift (-25C-85C), note 2


Offset Warm-up Shift, note 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (-25C-85C), note 2

0.25

%fs

%span

Maximum

Units

all sensors

Minimum

e www.allsensors.com

Parameter, note 1

Performance Characteristics for 20 INCH-G-P4V-MINI


Nominal

H2O

20.0

Operating Range, gage pressure


Output Span, note 5

3.90

4.0

4.1

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

20

mvolt

Offset Temperature Shift (-25C-85C), note 2


Offset Warm-up Shift, note 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (-25C-85C), note 2

0.25

%fs

%span

Maximum

Units

f 408 225 2079

Minimum

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Parameter, note 1

Performance Characteristics for 30 INCH-Dx-P4V-MINI


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal
30.0

H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

20

mvolt

Offset Temperature Shift (-25C-85C), note 2


Offset Warm-up Shift, note 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (-25C-85C), note 2

All Sensors

0.25

%fs

%span

DS-0102 Rev A
3-12

Performance Characteristics for 30 INCH-G-P4V-MINI


Parameter, NOTE 1

Minimum

Operating Range, gage pressure


Output Span, NOTE 5
Offset Voltage @ zero pressure

Nominal

Maximum

Units
H2O

30.0
3.9

4.0

4.1

volt

0.15

0.25

0.35

volt

20

mvolt

Offset Temperature Shift (-25C-85C), NOTE 2


Offset Warm-up Shift, NOTE 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, NOTE 4

0.05

0.25

%fs

%span

Maximum

Units

Span Shift (-25C-85C), NOTE 2

Performance Characteristics for 60 INCH-Dx-P4V-MINI


Parameter, note 1

Minimum

Operating Range, differential pressure


Output Span, note 5
Offset Voltage @ zero differential pressure

Nominal
60.0

H2O

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

20

mvolt

Offset Temperature Shift (-25C-85C), note 2


Offset Warm-up Shift, note 3

mvolt

Offset Position Sensitivity (1g)

mvolt

Offset Long Term Drift (one year)

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (-25C-85C), note 2

0.25

%fs

%span

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is
typically less than 100 useconds.

Specification Notes
NOTE 1:

ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE FRONT PORT.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS
FOR MINUS TO PLUS FULL SCALE PRESSURE.
OTHERWISE SPECIFIED.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

MiniatureAmplifiedLowPressureSensors
3-12

M iniature Amplified Pressure Sensors


0.3 psi to 100 psi Pressure Sensors

Features

all sensors

0 to 0.3 to 0 to 30 psi Pressure Ranges


Ratiometric 4V Output
Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Instrumentation
HVAC Instrumentation

The Miniature Amplified line of pressure sensors is based upon technology developed over years of development in the pressure sensor
industry. This model provides a ratiometric 4-volt output with superior output characteristics. The sensor housing has been designed
specifically to reduce package induced parasitic stress and strain. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.

e www.allsensors.com

General Description

internally compensated using an ASIC compensation technique. This series is intended for use with non-corrosive, non-ionic working fluids
such as air, dry gases and the like.

a 16035 Vineyard Blvd. Moragtn Hill, CA 95037 p 408 225 4314

The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Physical Dimensions
0.30
(7.6)

0.50
(12.7)
B-port
A-port

0.380

0.62
(15.7)

Pin 1 2 3 4
0.10
Typical
(2.54)

0.080 O.D.
(2.00)

D1 version

D2 version

or G verison

Equivalent Circuit

All

Sensors

f 408 225 2079

These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. Each sensor is

DS-0103 Rev A
3-13

Pressure Sensor Ratings

Environmental Specifications
+4.5 to +5.5 Vdc

Supply Voltage, Vs

Temperature Ranges

-10 to +10 psig

Common-mode pressure

Compensated

250C

Lead Temperature, max


(soldering 2-4 sec.)

5 to 50 C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Nominal Span

Proof Pressure

Burst Pressure

0.3 PSI-Dx-4V-MINI

0.3 PSI

4V

5 PSI

10 PSI

0.3 PSI-G-4V-MINI

0 - 0.3 PSI

4V

5 PSI

10 PSI

1 PSI-Dx-4V-MINI

1 PSI

4V

5 PSI

10 PSI

1 PSI-G-4V-MINI

0 - 1 PSI

4V

5 PSI

10 PSI

5 PSI-Dx-4V-MINI

5 PSI

4V

15 PSI

30 PSI

5 PSI-G-4V-MINI

0 - 5 PSI

4V

15 PSI

30 PSI

15 PSI-A-4V-MINI

0 - 15 PSIA

4V

45 PSI

60 PSI

15 PSI-Dx-4V-MINI

15 PSI

4V

45 PSI

60 PSI

15 PSI-G-4V-MINI

0 - 15 PSI

4V

45 PSI

60 PSI

30 PSI-A-4V-MINI

0 - 30 PSIA

4V

60 PSI

60 PSI

30 PSI-Dx-4V-MINI

30 PSI

4V

60 PSI

60 PSI

30 PSI-G-4V-MINI

0 - 30 PSI

4V

60 PSI

100 PSI

BARO-A-4V-MINI

600 - 1100 mbar

4V

45 PSI

60 PSI

Performance Characteristics for 0.3 PSI-Dx-4V-MINI


Parameter, note 1

Minimum

Operating Range, differential pressure

Nominal

Maximum

0.3

Units
PSI

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

Offset Temperature Shift (5C-50C), note 2

40

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Output Span, note 5


Offset Voltage @ zero differential pressure

Span Shift (5C-50C), note 2

Specification Notes
NOTE 1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS
ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS FOR MINUS TO PLUS FULL SCALE PRESSURE.

M iniature Amplified Output Medium Pressure Sensor


3-13

Performance Characteristics for 0.3 PSI-G-4V-MINI


Minimum

Operating Range, gage pressure

Nominal

Maximum

0.3

Units
PSI

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (5C-50C), note 2

40

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Span Shift (5C-50C), note 2

all sensors

Parameter, note 1

Minimum

Operating Range, differential pressure

Nominal
1.0

PSI

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

Offset Temperature Shift (5C to 50C), note 2

40

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Output Span, note 5


Offset Voltage @ zero differential pressure

Span Shift (5C to 50C), note 2

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 1 PSI-D-4V-MINI

Performance Characteristics for: 1 PSI-G-4V-MINI

Operating Range, gage pressure

PSI

1.0
3.90

4.0

4.10

volt

0.15

0.25

0.35

volt

Offset Temperature Shift (5C to 50C), note 2

40

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Output Span,

NOTE

Nominal

Offset Voltage @ zero pressure

Span Shift (5C to 50C), note 2

a 16035 Vineyard Blvd. Moragtn Hill, CA 95037 p 408 225 4314

Minimum

Parameter, NOTE 1

Performance Characteristics for: 5 PSI-D-4V-MINI


Parameter, NOTE 1

Minimum

Operating Range, differential pressure


Output Span, NOTE 5

Nominal
5.0

PSI

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Offset Voltage @ zero differential pressure

Span Shift (5C to 50C), note 2

All

Sensors

DS-0103 Rev A
3-13

Performance Characteristics for: 5 PSI-G-4V-MINI


Parameter, NOTE 1

Minimum

Units
PSI

3.90

4.0

4.10

volt

0.15

0.25

0.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

15

psia

NOTE

Maximum

5.0

Operating Range, gage pressure


Output Span,

Nominal

Offset Voltage @ zero pressure

Span Shift (5C to 50C), note 2

Performance Characteristics for 15 PSI-A-4V-MINI


Parameter, note 1

Minimum

Operating Range, absolute pressure

Nominal

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Span Shift (5C to 50C), note 2

Performance Characteristics for 15 PSI-Dx-4V-MINI


Parameter, note 1

Minimum

Operating Range, differential pressure

Nominal
15.0

PSI

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

1100

mBar

Output Span, note 5


Offset Voltage @ zero differential pressure

Span Shift (5C to 50C), note 2

Performance Characteristics for BARO-A-4V-MINI


Parameter, note 1

Minimum

Nominal

Operating Range, absolute pressure

600

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Span Shift (5C to 50C), note 2

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

M iniature Amplified Output Medium Pressure Sensor


3-13

Performance Characteristics for 15 PSI-G-4V-MINI


Operating Range, gage pressure

Nominal

Maximum

Units

15.0

PSI

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Span Shift (5C to 50C), note 2

all sensors

Minimum

Performance Characteristics for 30 PSI-Dx-4V-MINI


Minimum

Operating Range, differential pressure

Nominal
30.0

Output Span, note 5

PSI

1.90

2.0

2.10

volt

2.15

2.25

2.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Offset Voltage @ zero differential pressure

Span Shift (5C to 50C), note 2

e www.allsensors.com

Parameter, note 1

Minimum

Parameter, note 1

Nominal

PSI

30.0

Operating Range, gage pressure

f 408 225 2079

Performance Characteristics for 30 PSI-G-4V-MINI

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Maximum

Units

Span Shift (5C to 50C), note 2

Performance Characteristics for 30 PSI-A-4V-MINI


Parameter, note 1

Minimum

Operating Range, absolute pressure

Nominal

PSI

30.0

Output Span, note 5

3.90

4.0

4.10

volt

Offset Voltage @ zero pressure

0.15

0.25

0.35

volt

Offset Temperature Shift (5C to 50C), note 2

20

mvolt

Linearity, hysteresis error, note 4

0.5

%fs

%span

Span Shift (5C to 50C), note 2


Specification Notes
NOTE

1: ALL

PARAMETERS ARE MEASURED AT

5.0

VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED.

MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO

SHIFT IS RELATIVE TO 25C.


SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE
MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE
THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT
SCALE PRESSURE.
NOTE
NOTE

2:
3:
4:
5:

All

Sensors

PRESSURE

PORT B.

VOLTAGE RANGE IS

0.25

TO

4.25

VOLTS FOR MINUS TO PLUS FULL

DS-0103 Rev A
3-13

a 16035 Vineyard Blvd. Moragtn Hill, CA 95037 p 408 225 4314

Parameter, note 1

barometric amplified pressure sensors


600 to 1,100 mbar Barometric Pressure Sensor

Features

all sensors

Barometric Pressure Range


Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Monitoring
Altimeters
Chemical Analysis

e www.allsensors.com

General Description
The Miniature Amplified Output pressure sensors is based upon a proprietary technology to reduce all output
offset or common mode errors. This model provides a calibrated amplified output with superior output offset
characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time
period, and position sensitivity are all significantly reduced when compared to conventional compensation
methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to

These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage between
4.5 and 5.5 volts.

Physical Dimensions

Approvals
MKT

As Is

DATE

With Change

all sensors

MFG

As Is

DATE

With Change

ENG

As Is

DS-0040 Rev C

DATE

With Change

QA

As Is

DATE

With Change

01
3-14

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

f 408 225 2079

provide a very linear output to measured pressure.

Pressure Sensor Characteristics Maximum Ratings


Supply Supply Voltage VS
Lead Temperature
(soldering 2-4 sec.)

+4.5 to +5.5Vdc
250C

Environmental Specifications
Temperature Ranges
Compensated
Operating

see specification
-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Compensated Range

BARO-A-4V-MINI

600 to 1,100 mbar

5 to 50 C

BARO-A-4V--MINI-PRIME

600 to 1,100 mbar

-25 to 85 C

BARO-A-4V-MINI-MIL

600 to 1,100 mbar

-40 to 125 C

Equivalent Circuit

02

barometric amplified miniature pressure sensors


3-14

Parameter, note 1

Minimum

Nominal

Maximum

Units

1100

mBar

Operating Range, absolute pressure

600

Output Voltage @1,100 mbar

4.15

4.25

4.35

volt

Output Voltage @ 600 mbar

0.15

0.25

0.35

volt

20

mvolt

0.50

%fs

%span

Maximum

Units

1100

mBar

Offset Temperature Shift (5C to 50C), note 2


Linearity, hysteresis error, note 4

0.05

Span Shift (5C to 50C), note 2

all sensors

Performance Characteristics for BARO-A-4V-MINI

Parameter, note 1

Minimum

Nominal

Operating Range, absolute pressure

600

Output Voltage @1,100 mbar

4.15

4.25

4.35

volt

Output Voltage @ 600 mbar

0.15

0.25

0.35

volt

20

mvolt

0.50

%fs

%span

Offset Temperature Shift (-25C to 85C), note 2


Linearity, hysteresis error, note 4

0.05

f 408 225 2079

Span Shift (-25C to 85C), note 2

e www.allsensors.com

Performance Characteristics for BARO-A-4V-MINI-PRIME

Parameter, note 1

Minimum

Nominal

Maximum

Units

1100

mBar

Operating Range, absolute pressure

600

Output Voltage @1,100 mbar

4.15

4.25

4.35

volt

Output Voltage @ 600 mbar

0.15

0.25

0.35

volt

20

mvolt

0.50

%fs

%span

Offset Temperature Shift (-40C to 125C), note 2


Linearity, hysteresis error, note 4

0.05

Span Shift (-40C to 125C), note

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Performance Characteristics for BARO-A-4V-MINI-MIL

Specification Notes
1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE B-PORT.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: MEASURED AT ONE- HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE

OTHERWISE SPECIFIED.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

all sensors

DS-0040 Rev C
3-14

barometric pressure sensors


Barometrici Pressure Sensors

600 to 1,100 mbar Barometric Pressure


Options:

all sensors

Ratiometric Output
Fixed 4V Output with internal Voltage Reference
Temperature Compensated (-25C to 85C, -40C to 125C, 5 C
to 50C)
Calibrated Zero and Span

Applications
Medical Instrumentation
Environmental Controls
Chemical Analysis

e www.allsensors.com

General Description
These Barometric pressure sensors are based upon a proprietary package technology to reduce errors. This
model provides a fixed 4-volt output with superior output characteristics. The sensor housing has been designed
specifically to reduce package induced parasitic stress and strain. In addition the sensor utilizes a silicon,
micromachined (MEMS) structure to provide a very linear output to measured pressure. The sensor embodies a

f 408 225 2079

vacuum reference.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. Each sensor is internally compensated using an ASIC compensation technique. This series is

a 16035 Vineyard Blvd. Morgan HIll, CA 95037 p 408 225 4314

intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

Physical Dimensions

all sensors

DS-0041 Rev A

01
3-15

Pressure Sensor Ratings

Environmental Specifications

Lead Temperature, max


(soldering 2-4 sec.)

250C

Burst Pressure

60 psi

Temperature Ranges
Compensated

see below

Operating

-40 to 125 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Supply Voltage

Compensated Temperature Range

BARO-A-4V

600 - 1100 mbar

4.5 to 5.5 V

5C to 50C

BARO-A-4V-PRIME

600 - 1100 mbar

4.5 to 5.5 V

-25C to 85C

BARO-A-4V-MIL

600 - 1100 mbar

4.5 to 5.5 V

-40C to 125C

BARO-A-4V-PRIME-REF

600 - 1100 mbar

5.5 to 16 V

-25C to 85C

Performance Characteristics for BARO-A-4V


Parameter, note 1

Minimum

Nominal

Maximum

Units

Operating Range, absolute pressure

600

1100

mBar

Output Voltage @1,100 mbar

4.20

4.25

4.30

volt

Output Voltage @ 600 mbar

0.20

0.25

0.30

volt

20

mvolt

0.05

0.25

%fs

%span

Maximum

Units

1100

mBar

Offset Temperature Shift (5C to 50C), note 2


Linearity, hysteresis error, note 4
Span Shift (5C to 50C), note 2

Performance Characteristics for BARO-A-4V-PRIME


Parameter, note 1

Minimum

Nominal

Operating Range, absolute pressure

600

Output Voltage @ 1,100 mbar

4.20

4.25

4.30

volt

Output Voltage @ 600 mbar

0.20

0.25

0.30

volt

20

mvolt

0.25

%fs

%span

Offset Temperature Shift (-25C to 85C), note 2


Linearity, hysteresis error, note 4
Span Shift (-25C to 85C), note 2

02

0.05

barometric pressure sensors amplified output


3-15

Minimum

Nominal

Maximum

Units

1100

mBar

Operating Range, absolute pressure

600

Output Voltage @ 1,100 mbar

4.20

4.25

4.30

volt

Output Voltage @ 600 mbar

0.20

0.25

0.30

volt

20

mvolt

0.25

%fs

%span

Maximum

Units

1100

mBar

Offset Temperature Shift (-40C to 125C), note 2


Linearity, hysteresis error, note 4

0.05

Span Shift (-40C to 125C), note 2

e www.allsensors.com

Parameter, note 1

all sensors

Performance Characteristics for BARO-A-4V-MIL

Parameter, note 1

Minimum

Nominal

600

Output Voltage @ 1,100 mbar

4.20

4.25

4.30

volt

Output Voltage @ 600 mbar

0.20

0.25

0.30

volt

20

mvolt

0.25

%fs

%span

Offset Temperature Shift (-25C to 85C), note 2


Linearity, hysteresis error, note 4

0.05

Span Shift (-25C to 85C), note 2

a 16035 Vineyard Blvd. Morgan HIll, CA 95037 p 408 225 4314

Operating Range, absolute pressure

f 408 225 2079

Performance Characteristics for BARO-A-4V-PRIME-REF

Equivalent Circuit with


Internal Voltage Reference

Equivalent Circuit

Specification Notes
NOTE 1:

ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION FOR RATIOMETRIC PARTS AND 12.0 FOR PARTS WITH INTERNAL REFERENCE, FOR

THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED.

2: SHIFT IS RELATIVE TO 25C.


3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE
NOTE

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

all sensors

DS-0041 Rev A

03
3-15

MiniatureAmplifiedPressureSensors
cm H2O calibrated for Medical applications

Features

all sensors

cm H2O Pressure Ranges


Matched pressure port volumes
Temperature Compensated
Calibrated Zero and Span

Applications
Medical Instrumentation
Respiratory Breathing

e www.allsensors.com

General Description
The Miniature Amplified Output pressure sensors is based upon a proprietary technology to reduce all output
offset or common mode errors. This model provides a calibrated amplified output with superior output offset
characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time
period, and position sensitivity are all significantly reduced when compared to conventional compensation
methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to

f 408 225 2079

provide a very linear output to measured pressure.


These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage between
4.5 and 5.5 volts.

Physical Dimensions

0.30
(7.6)

0.50
(12.7)
B-port
A-port

0.380

0.62
(15.7)

Pin 1 2 3 4
0.10
Typical
(2.54)

All Sensors

0.080 O.D.
(2.00)

DS-0097 Rev A
3-16

Pressure Sensor Characteristics Maximum Ratings


+4.5 to

Supply Supply Voltage VS

+75.5Vdc

Common-mode pressure

10 psig

Lead Temperature
(soldering 2-4 sec.)

250C

Environmental Specifications
Temperature Ranges
Compensated

see specification

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number

Operating Pressure

Compensated Range

Proof Pressure

Burst Pressure

5 cmH2O-D1-4V-MINI

-0.2 to 5 cmH2O

5 to 50 C

50 cmH2O

200 cmH2O

20 cmH2O-D1-4V-MINI

-0.2 to 20 cmH2O

5 to 50 C

100 cmH2O

300 cmH2O

120 cmH2O-D1-4V-MINI

-10 to 120 cm H2O

5 to 50 C

300 cmH2O

600 cmH2O

5 cmH2O-D1-P4V-MINI

-0.2 to 5 cmH2O

-25 to 85 C

50 cmH2O

200 cmH2O

20 cmH2O-D1-P4V-MINI

-0.2 to 20 cmH2O

-25 to 85 C

100 cmH2O

300 cmH2O

120 cmH2O-D1-P4V-MINI

-10 to 120 cm H2O

-25 to 85 C

300 cmH2O

600 cmH2O

Specification Notes
NOTE 1:

ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE FRONT PORT.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS
FOR MINUS TO PLUS FULL SCALE PRESSURE.
OTHERWISE SPECIFIED.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Equivalent Circuit

MiniatureAmplifiedMedicalRangePressureSensors
3-16

Parameter, note 1

Minimum

Nominal

Maximum

Units

cmH2O

Operating Range, pressure

-0.2

Output Voltage, @5 cmH2O

4.40

4.5

4.6

volt

Output Voltage @ zero pressure

0.30

0.35

0.40

volt

Output Voltage @-0.2 cmH2O

0.13

0.18

0.23

volt

1.0

%span

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

15

mvolt

Offset Position Sensitivity (1g)

15

mvolt

Offset Long Term Drift (one year)

20

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (5C-50C), note 2

0.25

%fs

1.0

%span

Maximum

Units

20

cmH2O

all sensors

Performance Characteristics for 5 cmH2O-D1-4V-MINI

Nominal

Operating Range, pressure

-0.2

Output Voltage, @20 cmH2O

4.40

4.5

4.6

volt

Output Voltage @ zero pressure

0.30

0.35

0.40

volt

Output Voltage @-0.2 cmH2O

0.25

0.30

0.35

volt

1.0

%span

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

10

mvolt

Offset Position Sensitivity (1g)

10

mvolt

Offset Long Term Drift (one year)

10

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (5C-50C), note 2

0.25

%fs

1.0

%span

Maximum

Units

120

cmH2O

f 408 225 2079

Minimum

a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 20 cmH2O-D1-4V-MINI

Performance Characteristics for 120 cmH2O-D1-4V-MINI


Parameter, note 1
Operating Range, pressure

Minimum

Nominal

-10

Output Voltage, @120 cmH2O

4.40

4.5

4.6

volt

Output Voltage @ zero pressure

0.30

0.35

0.40

volt

Output Voltage @-10 cmH2O

0.23

0.28

0.33

volt

1.0

%span

Offset Temperature Shift (5C-50C), note 2


Offset Warm-up Shift, note 3

15

mvolt

Offset Position Sensitivity (1g)

15

mvolt

Offset Long Term Drift (one year)

20

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (5C-50C), note 2

All Sensors

0.25

%fs

1.0

%span

DS-0097 Rev A
3-16

Performance Characteristics for 5 cmH2O-D1-P4V-MINI


Parameter, note 1

Minimum

Nominal

Maximum

Units

cmH2O

Operating Range, pressure

-0.2

Output Voltage, @5 cmH2O

4.40

4.5

4.6

volt

Output Voltage @ zero pressure

0.30

0.35

0.40

volt

Output Voltage @-0.2 cmH2O

0.13

0.18

0.23

volt

1.0

%span

Offset Temperature Shift (-25 to 85C), note 2


Offset Warm-up Shift, note 3

15

mvolt

Offset Position Sensitivity (1g)

15

mvolt

Offset Long Term Drift (one year)

20

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (-25 to 85C), note 2

0.25

%fs

1.0

%span

Maximum

Units

20

cmH2O

Performance Characteristics for 20 cmH2O-D1-P4V-MINI


Parameter, note 1

Minimum

Nominal

Operating Range, pressure

-0.2

Output Voltage, @20 cmH2O

4.40

4.5

4.6

volt

Output Voltage @ zero pressure

0.30

0.35

0.40

volt

Output Voltage @-0.2 cmH2O

0.25

0.30

0.35

volt

1.0

%span

Offset Temperature Shift (-25 to 85C), note 2


Offset Warm-up Shift, note 3

10

mvolt

Offset Position Sensitivity (1g)

10

mvolt

Offset Long Term Drift (one year)

10

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (-25 to 85C), note 2

0.25

%fs

1.0

%span

Maximum

Units

120

cmH2O

Performance Characteristics for 120 cmH2O-D1-P4V-MINI


Parameter, note 1
Operating Range, pressure

Minimum

Nominal

-10

Output Voltage, @120 cmH2O

4.40

4.5

4.6

volt

Output Voltage @ zero pressure

0.30

0.35

0.40

volt

Output Voltage @-10 cmH2O

0.23

0.28

0.33

volt

1.0

%span

Offset Temperature Shift (-25 to 85C), note 2


Offset Warm-up Shift, note 3

15

mvolt

Offset Position Sensitivity (1g)

15

mvolt

Offset Long Term Drift (one year)

20

mvolt

Linearity, hysteresis error, note 4

0.05

Span Shift (-25 to 85C), note 2

0.25

%fs

1.0

%span

MiniatureAmplifiedMedicalRangePressureSensors
3-16

Amplified Pressure Sensors


-10 cm H2O to120 cm H2O Pressure Sensor

Features

all sensors

4 Volt ratiometric output


Temperature Compensated
Calibrated Zero and Span

Applications

e www.allsensors.com

Medical Instrumentation
Respiratory Breathing

General Description
This Amplified Output pressure sensor is based upon a proprietary technology to compensate all errors. This model
provides a calibrated amplified output with superior output characteristics. Output characteristics are tested at
pressure and temperature and then digitally compensated using a proprietary 3D mapping scheme. In addition the
sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to

f 408 225 2079

measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature
range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the

p 408 225 4314

like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

Physical Dimensions
Pin Size
0.010 x 0.020
(0.25 x 0.50)

0.10 Typical
(2.54)
0.174 to 0.190
(4.4 to 4.8)

Pin 1 2 3 4

0.66
(16.0)

0.21
(5.3)

Vout

0.42
(10.5)

A
1.08
(27.4)

Vs

Gnd

pin 1: Vs
0.48
(12.2)

0.55
(14.0)

NOTES:
1) Dimensions in inches (millimeters)

0.80
(20.3)

pin 2: Gnd

0.85
(21.6)

pin 3: Vout

1.10
(27.9)

pin 4: do not connect

Approvals
MKT

As Is

DATE

With Change

MFG

As Is

All Sensors

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0027 Rev B
3-17

a 6296 San Ignacio, Suite E & F, San Jose, CA 95119

0.25 MIN
(6.4)

Equivalent Circuit

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

+4.5 to +5.5 Vdc

Supply Supply Voltage VS


Common-mode pressure

Temperature Ranges
Compensated

10 psig

Lead Temperature
(soldering 2-4 sec.)

250C

see specification

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Part Number
120 CMH2O-D-4V
120 CMH2O-D-4V-PRIME

Operating Pressure

Compensated Range

Proof Pressure

Burst Pressure

-10 to 120 cm H2O

5 to 50 C

300 cmH2O

600 cmH2O

-10 to 120 cm H2O

-25 to 85 C

300 cmH2O

600 cmH2O

Performance Characteristics for 120 CMH2O-D-4V


Parameter, note 1

Minimum

Nominal

Maximum

Units

Operating Range, pressure

-10

--

120

cmH2O

Output Voltage, @120 cmH2O

4.40

4.5

4.6

volt

Output Voltage @ zero pressure

0.30

0.35

0.40

volt

Output Voltage @-10 cmH2O

0.23

0.28

0.33

volt

Offset Temperature Shift (5C-50C), note 2

--

--

1.0

%span

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Span Shift (5C-50C), note 2

--

--

1.0

%span

Performance Characteristics for 120 CMH2O-D-4V-PRIME


Parameter, note 1

Minimum

Nominal

Maximum

Units

Operating Range, pressure

-10

--

120

cmH2O

Output Voltage, @120 cmH2O

4.40

4.5

4.6

volt

Output Voltage @ zero pressure

0.30

0.35

0.40

volt

Output Voltage @-10 cmH2O

0.23

0.28

0.33

volt

Offset Temperature Shift (-25 to 85C), note 2

--

--

1.0

%span

Linearity, hysteresis error, note 4

--

0.05

0.25

%fs

Span Shift (-25 to 85C), note 2

--

--

1.0

%span

Specification Notes
1: All parameters are measured at 5.0 volt excitation, for the nominal full scale pressure and room temperature unless
Pressure measurements are with positive pressure applied to PORT B.
note 2: Shift is relative to 25C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 0.35V to 4.5V
volts for minus to plus full scale pressure.
note

otherwise specified.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of
any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Amplified Pressure Sensors


3-17

Basic Output

BLV Series Low Voltage Pressure Sensors


Features

all sensors

0 to 1 H2O to 0 to 30 H2O Pressure Ranges


uPower Low Supply Voltage (0.9V to 1.8V)
90% Less Power Than Mini-Basic Series
0.3% Linearity
Improved Front to Back Linearity
Excellent Position Sensitivity
Improved Warm-Up Shift Distribution
Parylene Coating Available Upon Request

Applications
Medical Instrumentation
Environmental Controls
HVAC
Portable / Hand Held Devices

The BLV Series Basic Sensor is based on All Sensors CoBeam2 TM Technology. The device provides a high output signal at a low
operating voltage and reduces the overall supply voltage while maintaining comparable output levels to traditional equivalent basic
sensing elements. This lower supply voltage gives rise to improved warm-up shift while the CoBeam2 Technology itself reduces
package stress susceptibility resulting in improved overall long term stability. The technology also vastly improves position sensitivity compared to conventional single die devices.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The output is also

Equivalent Circuit

Standard Pressure Ranges


Proof Pressure

Burst Pressure

BLV-L01D

1 inH2O

100 inH2O

300 inH2O

BLV-L05D

5 inH2O

200 inH2O

300 inH2O

BLV-L10D

10 inH2O

200 inH2O

300 inH2O

BLV-L20D

20 inH2O

200 inH2O

500 inH2O

BLV-L30D

30 inH2O

200 inH2O

800 inH2O

Vs

-Out

p 408 225 4314

Operating Range

+Out

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Device

f 408 225 2079

ratiometric to the suply voltage and is operable from 0.9 to 1.8 volts DC.

Gnd

Pressure Sensor Maximum Ratings

Environmental Specifications

Supply Voltage (Vs)

6 Vdc

Common Mode Pressure

5 psig

Lead Temperature (soldering 2-4 sec.)

Temperature Ranges
Operating
Storage

270 C

-25 to 85 C
-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Approvals
MKT

As Is

DATE

With Change

All Sensors

MFG

As Is

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

e www.allsensors.com

General Description

DATE

With Change

DS-0275 Rev A
4-1

Performance Characteristics for BLV Series


ALL PARAMETERS ARE MEASURED AT 1.8 VOLT EXCITATION AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE
PRESSURE APPLIED TO PORT B (THE ONLY PORT FOR THE SINGLE PORT CONFIGURATION).

Parameter

Min

Typ

Max

Units

Notes

4.5
13.5
18.0
22.0
25.0

8.0
24.0
32.0
38.0
42.0

11.5
34.5
46.0
55.0
60.0

mV
mV
mV
mV
mV

4
4
4
4
4

Offset Voltage @ Zero Diff. Pressure

10

mV

Offset Temperature Shift (0C-70C)

-25.0

uV/C

Offset Warm-up Shift

20.0

100

uV

Offset Position Sensitivity (1g)

20.0

uV

Offset Long Term Drift (One Year)

120

uV

Linearity, Hysteresis Error

0.10

0.30

%FSS

Response Time (10% to 90% Pressure Response)

100

uS

Front to Back Linearity

0.25

%FSS

Temperature Effect on Resistance (0C-70C)

2800

ppm/C

Temperature Effect on Span (0C-70C)

-1900

ppm/C

Input Resistance

3.0

k ohm

Output Resistance

3.0

k ohm

Output Span
L01D @ 1 inH2O
L05D @ 5 inH2O
L10D @ 10 inH2O
L20D @ 20 inH2O
L30D @ 30 inH2O

Specification Notes
NOTE 1: SHIFT IS RELATIVE TO 25C.
NOTE 2: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 3: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 4: THE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN FULL SCALE OUTPUT VOLTAGE AND THE OFFSET VOLTAGE.
NOTE

5: FRONT-BACK LINERITY COMPUTED AS: Lin FB

Span Front

1 100%

Span Back

How To Order

BLV-

Series
Pressure Range
Option

Description

L01D

1 inH2O

L05D

5 inH2O

L10D

10 inH2O

L20D

20 inH2O

L30D

30 inH2O

Coating

Package
Option

Option
Description

B1NS

Two Ports Same Direction

B2NS

Two Ports Opposite Direction

BGNS

One Port

Description

No Coating

Parylene Coating

(Consult with factory for parylene coating)

Example: BLV-L10D-B1NS-N
BLV Series Low Voltage Pressure Sensors
4-1

Package Drawings

all sensors

B1NS Package

Pinout

e www.allsensors.com

1) Gnd
2) -Out
3) Vs
4) +Out

f 408 225 2079

B2NS Package

Pinout

p 408 225 4314

1) Gnd
2) -Out
3) Vs
4) +Out

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

BGNS Package

Pinout
1) Gnd
2) -Out
3) Vs
4) +Out

All Sensors

DS-0275 Rev A
4-1

Suggested Pad Layout

2.54
0.100
(typ.)

0.035~0.039 inch
(Finished Size)

PAD-01

Package Characteristics

Package ID

Approximate Port Volume


Port A Port B Units

Weight

Units

B1NS

181

176

mm3

1.2

Grams

B2NS

181

176

mm3

1.2

Grams

BGNS

1.5

176

mm3

0.9

Grams

Product Labeling

All Sensors
BLV-L01D
B1NS-N
R9J21-3

Company
Part Number
Lot Number

Device Label

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.

BLV Series Low Voltage Pressure Sensors


4-1

BLVR Series Low Voltage Pressure Sensors


Features

all sensors

0 to 1 H2O to 0 to 30 H2O Pressure Ranges


Low Supply Voltage (1.8V to 3.3V)
40% Less Power Than Mini-Basic Series
0.3% Linearity
Improved Front to Back Linearity
Offset Compensated
Superior Position Sensitivity
Improved Warm-Up Shift Distribution
Parylene Coating Available Upon Request

Applications
Medical Instrumentation
Environmental Controls
HVAC
Portable / Hand Held Devices

e www.allsensors.com

General Description
The BLVR Series Basic Sensor is based on a Dual Die Reference technology to reduce all output offset or common mode errors. It
also incorporates All Sensors CoBeam2 TM Technology to reduce the overall supply voltage while maintaining comparable output
levels to traditional equivalent basic sensing elements. This lower supply voltage gives rise to improved warm-up shift while the
CoBeam2 Technology itself reduces package stress susceptibility resulting in improved overall long term stability. The technology
also vastly improves position sensitivity to nearly unmeasurable levels.

f 408 225 2079

This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The output is also
ratiometric to the suply voltage and is operable from 1.8 to 3.3 volts DC.

Operating Range

Proof Pressure

Burst Pressure

BLVR-L01D

1 inH2O

100 inH2O

300 inH2O

BLVR-L05D

5 inH2O

200 inH2O

300 inH2O

BLVR-L10D

10 inH2O

200 inH2O

300 inH2O

BLVR-L20D

20 inH2O

200 inH2O

500 inH2O

BLVR-L30D

30 inH2O

200 inH2O

800 inH2O

Vs

-Out

+Out

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Device

p 408 225 4314

Equivalent Circuit

Standard Pressure Ranges

Gnd

Pressure Sensor Maximum Ratings

Environmental Specifications

Supply Voltage (Vs)

6 Vdc

Common Mode Pressure

5 psig

Lead Temperature (soldering 2-4 sec.)

Temperature Ranges
Operating
Storage

270 C

-25 to 85 C
-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Approvals
MKT

As Is

DATE

With Change

All Sensors

MFG

As Is

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0280 Rev A
4-2

Performance Characteristics for BLVR Series


ALL PARAMETERS ARE MEASURED AT 3.3 VOLT EXCITATION AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE
PRESSURE APPLIED TO PORT B (THE ONLY PORT FOR THE SINGLE PORT CONFIGURATION).

Parameter

Min

Typ

Max

Units

Notes

4.5
13.5
18.0
22.0
25.0

8.0
24.0
32.0
38.0
42.0

11.5
34.5
46.0
55.0
60.0

mV
mV
mV
mV
mV

4
4
4
4
4

Offset Voltage @ Zero Diff. Pressure

8.0

mV

Offset Temperature Shift (0C-70C)

0.1

mV

Offset Warm-up Shift

10

80

uV

Offset Position Sensitivity (1g)

0.2

uV

Offset Long Term Drift (One Year)

80

uV

Linearity, Hysteresis Error

0.1

0.3

%FSS

Response Time (10% to 90% Pressure Response)

100

uS

Front to Back Linearity

0.25

%FSS

Temperature Effect on Resistance (0C-70C)

2800

ppm/C

Temperature Effect on Span (0C-70C)

-1900

ppm/C

Input Resistance

1.5

k ohm

Output Resistance

1.5

k ohm

Output Span
L01D @ 1 inH2O
L05D @ 5 inH2O
L10D @ 10 inH2O
L20D @ 20 inH2O
L30D @ 30 inH2O

Specification Notes
NOTE 1: SHIFT IS RELATIVE TO 25C.
NOTE 2: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 3: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 4: THE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN FULL SCALE OUTPUT VOLTAGE AND THE OFFSET VOLTAGE.
NOTE

5: FRONT-BACK LINERITY COMPUTED AS: Lin FB

Span Front

1 100%

Span Back

How To Order

Series

BLVR-

Pressure Range
Option

Description

L01D

1 inH2O

L05D

5 inH2O

L10D

10 inH2O

L20D

20 inH2O

L30D

30 inH2O

Coating

Package

Option

Option
B1NS

Description
Two Ports Same Direction

B2NS

Two Ports Opposite Direction

BGNS

One Port

Description

No Coating

Parylene Coating

(Consult with factory for parylene coating)

Example: BLVR-L10D-B1NS-N
BLVR Series Low Voltage Pressure Sensors
4-2

Package Drawings

all sensors

B1NS Package

Pinout

e www.allsensors.com

1) Gnd
2) -Out
3) Vs
4) +Out

f 408 225 2079

B2NS Package

Pinout

p 408 225 4314

1) Gnd
2) -Out
3) Vs
4) +Out

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

BGNS Package

Pinout
1) Gnd
2) -Out
3) Vs
4) +Out

All Sensors

DS-0280 Rev A
4-2

Suggested Pad Layout

2.54
0.100
(typ.)

0.035~0.039 inch
(Finished Size)

PAD-01

Package Characteristics

Package ID

Approximate Port Volume


Port A Port B Units

Weight

Units

B1NS

181

173

mm3

1.2

Grams

B2NS

181

173

mm3

1.2

Grams

BGNS

1.5

173

mm3

0.9

Grams

Product Labeling

All Sensors
BLVR-L01D
B1NS-N
R9J21-3

Company
Part Number
Lot Number

Device Label

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.

BLVR Series Low Voltage Pressure Sensors


4-2

Surface Mount Basic Pressure Sensors


Features
5 inH2O Full Sacale to 100 psi Full ScalePressures
0.5 % linearity
Small LCC Footprint
ROHS Compliant

Applications

General Description

all sensors

Medical Instrumentation
Environmental Controls
HVAC

The BASIC Serices of pressure sensors use a silicon micromachined (MEMS) pressure sensor in the most basic configuration. The
package is a ceramic surface mount configuration to provide the smallest footprint possible. Best temperature compensation is
realized when the sensor has a constant current excitation. This series is intended for use with non-corrosive, non-ionic working fluids

e www.allsensors.com

such as air, dry gases and the like. Specifications are written for constant voltage of 3.0 volts. The output of the device is ratiometric to
the supply voltage.

-Out

+Out

Gnd

Part Marking

Solder pads are pre-tinned

7.62
.300 SQ.

a 16035 Vineyard Blvd Morgan Hill, CA 95037

LF Package

p 408 225 4314

Vs

PART MARKING
L05G - 5 inH2O
L10G - 10 inH2O
001G - 1 PSIG
005G - 5 PSIG
015G - 15 PSIG
015A - 15 PSIA
030G - 30 PSIG
060G - 60 PSIG
100G - 100 PSIG

LP Package

f 408 225 2079

Equivalent Circuit

Physical Dimensions

Dimensions: inch [mm]


3.81
.150
3.68
.145

CL

Pin 1

0.89
.035
1.4
.055

Port on Gage
devi ces only
0.89
2X .035

Part Marking

0.89
2X .035
2X
Pin 2 1 8 74.19
.165
Back Side (Common to LP and LF Packages)

PINOUT
Pin 1: Vs
Pin 2: +out
Pin 3: N.C. Reserved
Pin 4: N.C. Reserved
Pin 5: N.C. Reserved
Pin 6: N.C. Reserved
Pin 7: -out
Pin 8: Gnd

Approvals
MKT DATE

As Is

With Change

All Sensors

MFG DATE

As Is

With Change

ENG DATE

As Is

With Change

QA DATE

As Is

With Change

DS-0165 Rev C
4-3

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Voltage VS

6 Vdc

Temperature Ranges

Lead Temperature
(soldering 2-4 sec.)

270C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Standard Pressure Ranges


Ported

Non-ported

Part Number

Part Number

CSM-L05G-LP

CSM-L05G-LF

CSM-L10G-LP

Sensitivity (1)
Nominal

Std Dev.

Units

Proof Pressure

0 - 5 inH2O

8.40

1.10

mV/inH2O

3 PSI

CSM-L10G-LF

0 - 10 inH2O

1.65

0.19

mV/inH2O

3 PSI

CSM-001G-LP

CSM-001G-LF

0 - 1 PSI

22.8

2.60

mV/PSI

5 PSI

CSM-005G-LP

CSM-005G-LF

0 - 5 PSI

12.0

1.50

mV/PSI

15 PSI

CSM-015G-LP

CSM-015G-LF

0 - 15 PSI

4.40

0.58

mV/PSI

45 PSI

CSM-015A-LP

CSM-015A-LF

0 - 15 PSIA

4.40

0.58

mV/PSI

30 PSI

CSM-030G-LP

CSM-030G-LF

0 - 30 PSI

2.30

0.30

mV/PSI

100 PSI

CSM-100G-LP

CSM-100G-LF

0 - 100 PSI

0.96

0.13

mV/PSI

200 PSI

Operating Pressure

Common Performance Characteristic


Parameter (1)

Minimum

Nominal

Maximum

Units

Offset Voltage

--

1.0

5.0

mv

Temperature Effect on Offset (2)

--

--

uV/V/C

2300

2600

3300

ppm/C

-1700

-2200

-2700

ppm/C

Linearity error (4,6)

--

0.2

0.5

% FSS

Hysteresis error (6)

--

0.01

0.05

% FSS

Position Sensitivity (BST-L10G-xx) (6)

--

0.01

0.03

% FSS

Input Resistance (6)

2.7

3.3

4.0

kohms

Output Resistance (6)

2.7

3.3

4.0

kohms

--

0.1

--

% FSS

Temperature Effect on Resistance (2,6)


Temperature Effect on Span (2,6)

Long term stability of span (3)

Specification Notes
1: All parameters are measured at 3.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure measurements are with
positive pressure to the single port configuration.
note 2: Shift is relative to 25C.
note 3: Shift is within the first year of operation.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The span is the algebraic difference between full scale output voltage and the offset voltage.
note 6: Parameter is characterized and not 100% tested. Minimum and Maximum values indicated as a design reference.
note

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

DS-0165 Rev C


4-3

XHB SERIES PRESSURE SENSOR


Features
1 to 70 PSI, Absolute, Gage or Differential Pressure.
DIP Package.
RoHS compliant.

Media
To be used with non-corrosive, non-ionic working fluids such as clean dry
air, dry gases and the like.

Applications
Industrial and Pneumatic Controls.
Instrumentation and Medical Devices.

all sensors

General Description
The XHB pressure sensor provides uncalibrated and uncompensated analog millivolt output signal and is intended to be used with dry
air and non-corrosive gases. The sensors offer a wide selection of standard pressure ranges. Miniature DIP housing allows for spacesaving PCB-mounting and maximum OEM design flexibility.

Pressure Sensor Characteristics

XHBP001

Proof Pressure1 Full-Scale Span2


Min.

Typ.

Max.

41 mV

83 mV

1 PSI

30 PSI

20 mV

XHBP005

5 PSI

30 PSI

39 mV

98 mV

158 mV

XHBP015

15 PSI

75 PSI

61 mV

103 mV

145 mV

XHBP030

30 PSI

100 PSI

49 mV

83 mV

116 mV

XHBP070

70 PSI

100 PSI

58 mV

96 mV

136 mV

e www.allsensors.com

Operating Pressure

f 408 225 2079

Device

Specifications
Pressure Sensor Maximum Ratings

2.5 C/s
Approx. 3 min
50 s
40 s
15 s
260C
-3.5 C/s

Humidity Limits

p 408 225 4314

Lead Specifications
Average preheating temperature gradient
Soak time
Time above 217C
Time above 230C
Time above 250C
Peak Temperature
Cooling Temperature gradient

Temperature Ranges
Operating
Storage

+12 VDC

-40C to 85C
-40C to 125C
0 to 95% RH
(non condensing)

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Supply Voltage (VS)

Environmental Specifications

Equivalent Circuit
+Vs

-Vout

+Vout

GND1

All Sensors

GND2

Note:
GND1 & GND2 are internally
connected.

DS-0335 Rev B

Page 1

4-4

Performance Characteristics

(Vs = 5.0 VDC , TA= 25 C ,RH = 50%, common mode line pressure = 0 PSI, pressure applied to high pressure port)

Characteristics

Min

Typ

Max

Units

Zero Pressure Offset


P001
P005, P015, P030, P070

-40
-30

0
0

40
30

P001

-0.45

-0.22

%FSS/C

P005
P015, P030, P070

-0.20
-0.1

-0.07
0.02

0
0.1

%FSS/C
%FSS/C

Temperature Span Effects (25C to 85C)


-0.35
-0.25
-0.18
%FSS/C
-0.21
-0.20
-0.17
%FSS/C
0.20 0.26 0.31 %/C

Temperature Effects (25C to 85C) - Bridge Impedance


Non-Linearity
P001
P005, P015, P030, P070

Hysteresis
Repeatability
Long Term Stability
Bridge Resistance
Response Time

-
-
-
-
-
2.8
-

0.5
0.1
0.1
0.5
0.1
3.3
100

1.1
0.5
-
-
-
3.8
-

mV
mV

Temperature Offset Effects (25C to 85C)

P001
P005, P015, P030, P070

Notes

%FSS
%FSS
%FSS 4
%FSS
%FSS 5
k
sec 6

Specification Notes
1.

2.
3.
4.
5.
6.

Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the
sensing element.
Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.
Non-linearity refers to the Best Straight Line fit, measured for offset pressure, full scale pressure and 1/2 full scale pressure.
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
Long term stability over a one year period.
Response time for a zero to full scale span pressure step change, 10 to 90 % rise time.

XHB Series Amplified Pressure Sensor

Page 2

4-4

Package Drawings

vent hole
2,69
3,03

15,70

Note:
The polarity indicated
is for pressure applied
to high pressure port
(forward gage).

80

3,41
2,54

3,16

9,28 0,50

5,08

GND1 & GND2 are


internally connected. It
is acceptable to connect
either or both grounds to
application ground.

high pressure port

View X

+Vs1 & +Vs2 are


internally connected. It
is acceptable to connect
either or both supply pins
to application supply.

2,30 0,30

Label
16,90 0,50

0,70

8,90 0,50

5,80 0 ,30

3,10 0,50
3,80 0,50
2 0,50

0,46

Connection
+Vout
GND1
-Vout
+Vs1
GND2
+Vs2

all sensors

0,50

+0,20

15 - 0,10

0,
R

3 2 1

Pin
1
2
3
4
5
6

6,90 0,50
8

4 5 6

e www.allsensors.com

+0,20

11,90 - 0,10

0,

40

0,75 0,30

All Sensors
TITLE:

Dimensions are in mm

SIZE

FK-Series Package
FILE NAME

FK04 Package Rev A

f 408 225 2079

FK04

3 2 1

Note:
The polarity indicated
is for pressure applied
to high pressure port
(forward gage).

3,16

0,75 0,30

9,28 0,50

GND1 & GND2 are


internally connected. It
is acceptable to connect
either or both grounds to
application ground.

high pressure port


+0,20

11,90 - 0,10

+0,20

+Vs1 & +Vs2 are


internally connected. It
is acceptable to connect
either or both supply pins
to application supply.

3,10 0,50

15 - 0,10

0,46

2 0,50
3,80 0,50

5,80 0,30

16,90 0,50
8,90 0,50

0,70

0,

40

View X

p 408 225 4314

ve n t hole
0

Connection
+Vs1
GND1
+Vs2
-Vout
GND2
+Vout

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Label

8
R0
,8

Pin
1
2
3
4
5
6

6,90 0,50

15,70 0,50

3,03

4 5 6

2,69

2,30 0,30

FK06

3,41
2,54
5,08

All Sensors
Dimensions are in mm

TITLE:

SIZE

All Sensors

FK-Series Package
FILE NAME

FK06 Package Rev A

DS-0335 Rev B

Page 3
4-4

Package Drawings (Contd)

+0,20

11,90 - 0,10

6,30 0,50

2,68
2,30

15 - 0,10

+0,20

15,70 0,50

4 5 6

3,41
2,54

0,25

3 2 1

Pin
1
2
3
4
5
6

7 0,50
3,40 0,50

4,10 0,50

FK02

Note:
The polarity indicated
is for pressure applied
to high pressure port
(forward gage).

9,28 0,50

GND1 & GND2 are


internally connected. It
is acceptable to connect
either or both grounds to
application ground.

1,90 0,50
3,90 0,50

high pressure port


View X

Label

2,30 0,30

9,10 0,50

11,15
18,75
19,50 0,50

+Vs1 & +Vs2 are


internally connected. It
is acceptable to connect
either or both supply pins
to application supply.

0,75 0,30

5,20 0,50

R0

,40

0,70

11 0,50
9,64 0,50
8,90 0,50

5,80 0,30
3,35 0,50

5,08

0,46

Connection
+Vs1
GND1
+Vs2
-Vout
GND2
+Vout

All Sensors
TITLE:

Dimensions are in mm

SIZE

FK-Series Package
FILE NAME

FK02 Package Rev A

How To Order
Options

Example:

Series
XHB

XHB

Pressure Range

Pressure Mode

Package

P001

1 PSI

A1

Absolute

F2

FK02
DIP, 2 ports
same side

P005

5 PSI

Differential
(Bidirectional)

Z3

FK04, FK06
DIP, 1 port
axial

P015

15 PSI

Gage
(Unidirectional)

P030

30 PSI

P070

70 PSI

P001

Options
P

Prime Grade

Notes:
1: Only available from 15 PSI and higher.
2: Standard for differential devices, "D".
3: FK04 is standard for Absolute devices. FK06 is standard
for gage devices.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described
herein, neither does it convey any license under its patent rights nor the rights of others.

XHB Series Amplified Pressure Sensor

Page 4

4-4

Miniature Basic Pressure Sensors


Offset Compensated
Pressure Sensors

Features

all sensors

0 to 1 H2O to 0 to 30 H2O Pressure Ranges


0.5 % linearity
Offset Compensated

Applications
Medical Instrumentation
Environmental Controls
HVAC

General Description

The Miniature BASIC series pressure sensors are based upon a proprietary technology to reduce the size of the sene www.allsensors.com

sor and yet maintain a high level of performance. The technology is currently being patented. Output offset errors
due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all
significantly reduced when compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.
These offset compensated sensors give an accurate and stable output over a wide temperature range. This series is

f 408 225 2079

intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +6V
is acceptable.

Physical Dimensions

Input Resittance

1.66 k ohm

Output Resistance

1.66 k ohm

TCR

2600 ppm/C

TCS

-2200 ppm/C.

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

p 408 225 4314

Equivalent Circuit

Approvals
MKT

As Is

DATE

With Change

MFG

As Is

All Sensors

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0105 Rev B
4-5

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Supply Voltage VS

6 Vdc

Temperature Ranges

Common-mode pressure

5 psig

Compensated

Lead Temperature
(soldering 2-4 sec.)

250C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH

0 to 70 C

(non condensing)

Standard Pressure Ranges


Single in Line Packages-SIP
One Port

Two Ports Same Side

Two Ports Opposite Side

Operating Pressure

Part Number

Part Number

1 INCH-G-BASIC

0 - 1 H2O

1 INCH-D1-BASIC

1 INCH-D2-BASIC

5 INCH-G-BASIC

0 - 5 H2O

5 INCH-D1-BASIC

5 INCH-D2-BASIC

10 INCH-G-BASIC

0 - 10 H2O

10 INCH-D1-BASIC

10 INCH-D2-BASIC

20 INCH-G-BASIC

0 - 20 H2O

20 INCH-D1-BASIC

20 INCH-D2-BASIC

30 INCH-G-BASIC

0 - 30 H2O

30 INCH-D1-BASIC

30 INCH-D2-BASIC

Part Number

Performance Characteristics for 1 INCH-x-BASIC


Minimum

Nominal

Maximum

Units

--

1.0

--

H2O

4.0

7.0

14.0

mV

Offset Voltage @ zero differential pressure

--

--

10

mV

Offset Temperature Shift (0C-70C), note 2

--

0.1

--

mV

Offset Warm-up Shift, note 3

--

10

--

uV

Offset Position Sensitivity (1g)

--

15

--

uV

Offset Long Term Drift (one year)

--

80

--

uV

Linearity, hysteresis error, note 4

--

0.1

0.5

%fs

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

5.0

--

H2O

Output Span, @ 5 H2O, note 5

15

22.5

30

mV

Offset Voltage @ zero differential pressure

--

--

10

mV

Offset Temperature Shift (0C-70C), note 2

--

0.1

--

mV

Offset Warm-up Shift, note 3

--

10

--

uV

Offset Position Sensitivity (1g)

--

15

--

uV

Offset Long Term Drift (one year)

--

80

--

uV

Linearity, hysteresis error, note 4

--

0.1

0.5

%fs

Parameter, note 1
Operating Range, differential pressure
Output Span, @ 1 H2O, note 5

Performance Characteristics for 5 INCH-x-BASIC


Parameter, note 1

Miniature Basic Pressure Sensors


4-5

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

10.0

--

H2O

Output Span, @ 10 H2O, note 5

15

30

45

mV

Offset Voltage @ zero differential pressure

--

--

10

mV

Offset Temperature Shift (0C-70C), note 2

--

0.1

--

mV

Offset Warm-up Shift, note 3

--

10

--

uV

Offset Position Sensitivity (1g)

--

10

---

uV

Offset Long Term Drift (one year)

--

80

--

uV

Linearity, hysteresis error, note 4

--

0.1

0.5

%fs

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

20.0

--

H2O

Output Span, @ 20 H2O, note 5

15

30

45

mV

Offset Voltage @ zero differential pressure

--

--

10

mV

Offset Temperature Shift (0C-70C), note 2

--

0.1

--

mV

Offset Warm-up Shift, note 3

--

10

--

uV

Offset Position Sensitivity (1g)

--

--

uV

Offset Long Term Drift (one year)

--

80

--

uV

Linearity, hysteresis error, note 4

--

0.1

0.5

%fs

Minimum

Nominal

Maximum

Units

Operating Range, differential pressure

--

30.0

--

H2O

Output Span, @ 30 H2O, note 5

15

30

45

mV

Offset Voltage @ zero differential pressure

--

--

10

mV

Offset Temperature Shift (0C-70C), note 2

--

0.1

--

mV

Offset Warm-up Shift, note 3

--

10

---

uV

Offset Position Sensitivity (1g)

--

---

uV

Offset Long Term Drift (one year)

--

80

--

uV

Linearity, hysteresis error, note 4

--

0.05

0.5

%fs

Parameter, note 1

all sensors

Performance Characteristics for 10 INCH-x-BASIC

f 408 225 2079

Parameter, note 1

e www.allsensors.com

Performance Characteristics for 20 INCH-x-BASIC

a 16035 Vineyard Blvd. Morgan Hill, CA 95037

Parameter, note 1

p 408 225 4314

Performance Characteristics for 30 INCH-x-BASIC

Specification Notes
note 1: All parameters are measured at 4.5 volt excitation, for the nominal full scale pressure and room temperature unless
otherwise specified. Pressure measurements are with negative pressure applied to the TOP-PORT (the only port for the
single port) configuration.
note 2: Shift is relative to 25C.
note 3: Shift is within the first hour of excitation applied to the device.
note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
note 5: The voltage added to the offset voltage at full scale pressure.
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of
any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

All Sensors

DS-0105 Rev B
4-5

BDS Series Pressure Sensor


Features
Dual Sensing Elements (Absolute & Differential)
Top constraint absolute sensing element for helium applications
Parylene coating available upon request
RoHS Compliant

all sensors

Applications
Gas Flow Measurement

General Description
The BDS Basic Pressure Sensor was designed with the idea of combining two sensing elements into one package. This sensor is
designed to provide a precise flow measurement by combining a differential and absolute sensing element in the same package.

e www.allsensors.com

By combining the differential and absolute sensing element, engineers can save cost and space in todays smaller devices.
The BASIC series pressure sensors are based upon a proprietary technology to reduce the size of the sensor and yet maintain a
high level of performance. Output offset errors due to position sensitivity; packaging stress and long term drift are all significantly
reduced when compared to conventional silicon sensors. In addition, the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

f 408 225 2079

The output of the device is ratiometric to the supply voltage.

Physical Dimensions

5.08
0.200

0.36
0.014

0.18
0.007 (typ)

1.27
0.050 (typ)

0.46
0.018

CL
Pin 1
14.43
0.569

3.81
0.150

10.80
0.425

Port A

Port B

4.83
0.190

6.35
0.250

4.83
0.190

7.11
0.280

3.19
0.126

19.94
0.785

9.53
0.375

9.53
0.375

3.18
R0.125

PINOUT
Pin 1: DP_Gnd +
Pin 2: DP_Gnd Pin 3: DP_+Out
Pin 4: AP_Gnd
Pin 5: DP_Vs
Pin 6: AP_-Out
Pin 7: DP_-Out
Pin 8: AP_Vs
Pin 9: AP_+Out

p 408 225 4314

1.02
0.040

16.51
0.650

a 16035 Vineyard Blvd Morgan Hill, CA 95037

10.16
0.400

22.86
0.900

Approvals
MKT

As Is

DATE

With Change

All Sensors

MFG

As Is

DATE

With Change

ENG

As Is

DATE

With Change

QA

As Is

DATE

With Change

DS-0266 Rev A
4-6

Pressure Sensor Characteristics Maximum Ratings

Environmental Specifications

Supply Voltage VS

6 Vdc

Temperature Ranges

Lead Temperature
(soldering 2-4 sec.)

270C

Operating

-25 to 85 C

Storage

-40 to 125 C

Humidity Limits

0 to 95% RH
(non condensing)

Equivalent Circuit

Differential Sensor (DP)

Absolute Sensor (AP)

Standard Pressure Range


Sensitivity (1)
Nominal

Std Dev.

Units

Proof Pressure

Burst Pressure

--

--

--

--

--

--

0 - 30 PSIA

7.5

1.25

mV/PSI

90 PSI

150 PSI

0 - 10 inH2O

3.0

0.40

mV/inH2O

15 PSI

30 PSI

--

--

--

--

--

--

Absolute

0 - 100 PSIA

3.0

0.28

mV/PSI

150 PSI

150 PSI

Differential

0 - 10 inH2O

3.0

0.40

mV/inH2O

15 PSI

30 PSI

Device Type

Operating Pressure

BDS-L10D030A
Absolute
Differential
BDS-L10D100A

Performance Characteristic: BDS-L10D030A


Absolute Element
Parameter (1)

Minimum

Nominal

Maximum

Units

+25

--

+125

mv

--

--

uV/V/C

Temperature Effect on Resistance (2,5)

1700

2600

3100

ppm/C

Temperature Effect on Span (2,5)

-1500

-1900

-2400

ppm/C

Linearity error (4,5)

--

0.2

0.5

% FSS

Hysteresis error

--

0.01

--

% FSS

Input Resistance

2.0

2.5

3.0

kohms

Output Resistance

2.0

2.5

3.0

kohms

Long term stability (3)

--

0.1

--

% FSS

Offset Voltage (@1 atm)


Temperature Effect on Offset (2)

DS-0266 Rev A

All Sensors
4-6

Nominal

Maximum

Units

--

5.0

25.0

mv

--

3.0

--

uV/V/C

2300

2600

3300

ppm/C

-1700

-2200

-2700

ppm/C

--

0.5

1.0

% FSS

--

0.01

--

% FSS

--

0.01

0.03

% FSS

Warm Up Shift

--

10.0

--

uV

Input Resistance

1.3

1.6

2.5

kohms

1.3

1.6

2.5

kohms

--

0.1

--

% FSS

Minimum

Nominal

Maximum

Units

-20.0

--

+120

mv

--

3.0

--

uV/V/C

Temperature Effect on Resistance (2,5)

1200

2600

3100

ppm/C

Temperature Effect on Span (2,5)

-1500

-1900

-2400

ppm/C

Linearity error (4,5)

--

0.2

0.5

% FSS

Hysteresis error

--

0.01

--

% FSS

Input Resistance

2.0

2.5

3.0

kohms

Output Resistance

2.0

2.5

3.0

kohms

Long term stability(3)

--

0.1

--

% FSS

Minimum

Nominal

Maximum

Units

--

5.0

25.0

mv

--

3.0

--

uV/V/C

2300

2600

3300

ppm/C

-1700

-2200

-2700

ppm/C

--

0.5

1.0

% FSS

--

0.01

--

% FSS

--

0.01

0.03

% FSS

Warm Up Shift

--

10

--

uV

Input Resistance

1.3

1.6

2.5

kohms

1.3

1.6

2.5

kohms

--

0.1

--

% FSS

Offset Voltage
Temperature Effect on Offset

(2)

Temperature Effect on Resistance


Temperature Effect on Span
Linearity error

(2,5)

(2,5)

(4,5)

Hysteresis error
Position Sensitivity

(5)

Output Resistance
Long term stability

(3)

e www.allsensors.com

Minimum

Parameter (1)

all sensors

Differential Element

Offset Voltage (@1 atm)


Temperature Effect on Offset (2)

p 408 225 4314

Parameter (1)

f 408 225 2079

Performance Characteristic: BDS-L10D100A


Absolute Element

Parameter (1)
Offset Voltage
Temperature Effect on Offset

(2)

Temperature Effect on Resistance


Temperature Effect on Span
Linearity error

(4,5)

Hysteresis error
Position Sensitivity

(5)

Output Resistance
Long term stability

All Sensors

(3)

(2,5)

(2,5)

a 16035 Vineyard Blvd Morgan Hill, CA 95037

Differential Element

DS-0266 Rev A
4-6

Ordering Information
Part Number

Configuration
Differential

Absolute

Sensor

Sensor

Package

BDS-L10D030A-N9

10 inH2O

30 PSIA

N9

BDS-L10D100A-N9

10 inH2O

100 PSIA

N9

Specification Notes
1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE TO PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25C.
NOTE 3: SHIFT IS WITHIN THE FIRST YEAR OF OPERATION.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: PARAMETER IS CHARACTERIZED AND NOT 100% TESTED. MINIMUM AND MAXIMUM VALUES INDICATED AS A DESIGN REFERENCE.
NOTE

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.

DS-0266 Rev A

All Sensors
4-6

Packaging

5-1

(millivolt, amplified, digital device)

A6 A-Package

A-Package
Six (6) leads
Two (2) ports cut 0.100
Barb fitting, port A only
Jogged lead bend

A 6C B J

Semi-Custom Example A6CBJ

D Cut 0.370
Port A Only

R Right Angle 0.100

Q Right Angle 0.075

J Jogged Bend

F Flat (Straight)

Lead Bend Options

Series Identifier

Number of Leads

Cut Option

A 6C B J
Fitting Options

Lead Bend Options

Semi Custom Extension

Local stock and delivery


Local stock and customization (additional charges apply)
Overseas customization (longer lead times, additional charges and minimum lot size apply)
Special tooling required (longer lead times, tooling charges and minimum lot size apply)

Standard Package Identifier

Notes
Standard :
Semi Custom :
Custom :
Full Custom :

D Barb Fitting
Port A and B

D Cut 0.150
Port A and B

E Cut 0.080
Port A Only

C Barb Fitting
Port B Only

B Barb Fitting
Port A Only

B Cut 0.085
Port A and B

C Cut 0.100
Port A and B

A No Fitting
Port A and B

Port Fitting Options

A No Cut
Port A and B

Port Cut Options

5-1

(amplified output device)

A4 A-Package

A-Package
Four (4) leads
Two (2) ports cut 0.100
Barb fitting, port A only
Jogged lead bend

A 4C B J

Semi-Custom Example A4CBJ

D Cut 0.370
Port A Only

R Right Angle 0.100

Q Right Angle 0.075

J Jogged Bend

F Flat (Straight)

Lead Bend Options

Series Identifier

Number of Leads

Cut Option

A 4C B J
Fitting Options

Lead Bend Options

Semi Custom Extension

Local stock and delivery


Local stock and customization (additional charges apply)
Overseas customization (longer lead times, additional charges and minimum lot size apply)
Special tooling required (longer lead times, tooling charges and minimum lot size apply)

Standard Package Identifier

Notes
Standard :
Semi Custom :
Custom :
Full Custom :

D Barb Fitting
Port A and B

D Cut 0.150
Port A and B

E Cut 0.080
Port A Only

C Barb Fitting
Port B Only

B Barb Fitting
Port A Only

B Cut 0.085
Port A and B

C Cut 0.100
Port A and B

A No Fitting
Port A and B

Port Fitting Options

A No Cut
Port A and B

Port Cut Options

All Sensors

E-Package

(millivolt, digital output device)

EGNS

EGNL

EGNJ

EGND

EGBS

EGBL

EGBJ

EGBD

E2NS

E2NJ

E2ND

E2BS

E2BD

E1NS

E1NJ

E1ND

E1BS

E1BD

P-Package
(amplified output device)

PTNS

PTNR

PTNQ

PTBS

PTBR

P2NS

P2NR

P2NQ

P2BS

P2BR

P1NS

P1NR

P1NQ

P1BS

P1BR
5-2

All Sensors

M-Package
(millivolt output device)

MTNT

MTNS

MTNR

MTNQ

MTND

MTBS

MTBR

MTBD

MLNT

MLNS

MLNR

MLNQ

MLND

MLBT

MLBS

MLBR

MLBQ

MLBD

MGNT

MGNS

MGNR

MGNQ

MGND

MGBT

MGBS

MGBR

MGBQ

MGBT

M2NT

M2NS

M2NR

M2NQ

M2ND

M2BS

M2BR

M2BD

M1NT

M1NS

M1NR

M1NQ

M1ND

M1BS

M1BR

M1BD
5-3

All Sensors

C-Package
(millivolt output device)

CPPT

CPPS

CPPR

CPPQ

CPPD

CPNT

CPNS

CPNR

CPNQ

CPND

CPFT

CPFS

CPFR

CPFQ

CPFD

CFNW

CFNT

CFNS

CFNR

CFNQ

CFND

CFFT

CFFS

CFFR

CFFQ

CFFD

5-4

All Sensors

B-Package
(basic output device)

BTNS

BTNR

BTNQ

BTBS

BTBR

BLNS

BLNR

BLNQ

BLBS

BLBR

BLBQ

BGNS

BGNR

BGNQ

BGBS

BGBR

BGBQ

B2NS

B2NR

B2NQ

B2BS

B2BR

B1NS

B1NR

B1NQ

B1BR

B1BS

5-5

All Sensors

L-Package

LP

LF

N-Package

N1BS

FA-Package

FA01

FA02
5-6

All Sensors

FB-Package

FB03

FB04

FK-Package

FK02

FK04

FK06

5-7

Additional Resources

Definition of Terms
Absolute Pressure: Pressure measured relative to a vacuum. Usually expressed in pounds per
square inch absolute (psia).
Altimetric Pressure Transducer: A barometric pressure transducer used to determine altitude
from the pressure altitude profile.
Auto-Referencing: A technique for eliminating errors by sampling one or more reference
pressures, then correcting the output signal function.
Barometric Pressure Transducer: An absolute pressure transducer measuring the local
ambient pressure.
Best Straight Line (BSL): The best straight line chosen such that the true transducer response
curve contains three points of equal maximum deviation.
Burst Pressure: The maximum pressure that may be applied to the sensor without causing the
sensor catastrophic failure.
Common-Mode Error: An error that is independent of the major input variable (input pressure).
For All Sensors transducers, all offset errors are common-mode errors.
Common Mode Pressure: The maximum pressure that may be applied to both sides of the
diaphragm simultaneously with causing changes in performance to the specifications. Patent US
6,023,978 (Dauenhauer et al.): some of the products manufactured by All Sensors Corporation
are licensed for use of the Honeywell US patent.6.023.978. This patent describes a technique for
compensating piezo resistive pressure sensors using dual die compensation with electrical cross
coupling and pneumatic cross coupling.
Differential Pressure: The pressure difference measured between two pressure sources. Usually
expressed in pounds per square inch differential (psid). When one source is a perfect vacuum, the
pressure difference is called absolute pressure. When one source is the local ambient, the
pressure is called gage pressure.
Differential Pressure Transducer: A device that measures the differential pressure between
two pressure sources piped to its inputs.
Error Band: The deviation of transducer response from its BSL, defined by lines on either side
of its BSL and including the maximum deviation measured for a given normal mode or common
mode error.
Full-Scale: The algebraic difference between endpoints. Where one endpoint is actual offset
voltage and the other endpoint is the upper limit of the range.

6-1

Full Scale Shift: The shift in sensor output voltage sensitivity to pressure over the temperature
range specified. This is equivalent to temperature coefficient of sensitivity. The characteristic of
this transfer curve is very close to a second order equation for the basic piezo resistive sensing
element. For the millivolt output devices, this is compensated with passive resistors; and for
amplified output device, it is ASIC compensated with a second order curve fit to the data taken
for each part over the pressure and temperature ranges specified. The characteristic of this
transfer curve does not change with any other conditions.
Gage Pressure: Pressure measured relative to ambient pressure (psig).
Hysteresis of Pressure: Pressure hysteresis is measured as the maximum difference between the
output at reference conditions before and after a pressure cycle.
Interchangeability: The error band defined by the maximum signal deviation obtained when a
transducer is replaced by any other transducer of the same type with equivalent pressure inputs
and temperature ranges.
Linearity: The maximum deviation of measured output at constant temperature (25C) from
"best straight line" determined by three points (offset pressure, full-scale pressure, and one-half
full-scale pressure) where Y= measured value for each device
Linearity, Hysteresis Error: The error in the output voltage response to pressure over the full
operating pressure range relative to the ideal output voltage response; the deviation from a first
order transfer curve response of output signal to pressure. This error is a function of pressure and
not a function of temperature. This error is computed by measuring pressure at three pressure
points; zero pressure. Full scale pressure and one half full scale pressure and computed on the
basis of a "best straight line" curve fit to the measured data.
Minimum/Maximum: Are the guaranteed limits for the specification. These limits are generally
one hundred percent tested with a guard band between the test limits and the specification limits.
Most Probable Error: The error band obtained by computing the square root of the sum of the
squares of all applicable errors specified for the transducer.
Nominal: It is the average value for a specification from product manufactured during the first
production run.
Normal Mode Error: An error that is a function of (and usually assumed to be proportional to)
the major input variable (input pressure). For All Sensors transducers, all span errors are normal
mode errors.
Offset Calibration: The error band defined by the maximum error in calibrating the offset
voltage.

6-1

Offset Error: The common-mode error band defined by the maximum deviation of offset
voltage from its specified value. It may include calibration, temperature, repeatability and
stability errors.
Offset Long Term Drift: The change in offset voltage that may occur over the time specified.
Possible causes to this characteristic for piezo resistive pressure sensors have been studied for
decades. There is, to date, no conclusive single cause or main causes to the error. Because most
of All Sensors low pressure sensors use dual die electrical cross coupling compensation, there is
inherent offset long term drift compensation. Products All Sensors tests for warm-up shift will
generally identify any offset long term drift problems and would be rejected.
Offset Position Sensitivity: The change in offset voltage due to a change in position of the
sensor. Sensors for measuring pressure exceeding 15 psi have virtually no position sensitivity.
Because the diaphragm of the sensor has mass, and because the mass to diaphragm thickness
ratio increases as the pressure range decreases, the sensitivity to position increases as the
pressure range decreases. Because most of All Sensors low pressure sensors use dual die
electrical cross coupling compensation there is inherent offset position sensitivity compensation
in even the most basic sensors.
Offset Repeatability: The error band expressing the ability of the transducer to reproduce the
offset voltage, measured at 25C, after exposure to any other temperature and pressure within the
specified range.
Offset Stability: The error band expressing the ability of the transducer to maintain the offset
voltage with constant pressure and temperature.
Offset Temperature Coefficient: The error band defined by the maximum deviation in offset
voltage as the temperature is varied from 25C to any other temperature within the specified
range.
Offset Temperature Shift: The change in output offset voltage over the specified temperature
range. For non amplified sensors the specification limits are tested at three temperature points;
25C, temperature maximum, temperature minimum, and back to 25C. For amplified pressure
sensors there are many more data points measured and the compensation is mathematically fit to
the data points. There is generally no consistent equation to describe the offset temperature shift
characteristic. Because most of All Sensors low pressure sensors use dual die electrical cross
coupling compensation there is inherent offset temperature shift compensation in even the most
basic sensor.
Offset Voltage: The output voltage when the sensor has zero differential pressure across the
diaphragm. For absolute pressure sensors there is zero differential pressure across the diaphragm
when the sensor is at absolute pressure of zero. For gage or differential pressure sensors there is
zero differential pressure when both sides of the diaphragm are subject to the same pressure.
Offset Warm-up Shift: The change in output offset voltage that may occur when power is
applied to the sensor during the first hour of operation. All Sensors tests all low pressure sensors

6-1

for this parameter. Because most of the companies low pressure sensors use dual die electrical
cross coupling compensation there is inherent offset warm-up shift compensation in even the
most basic sensors.
Operating Range: The pressure range over which the sensor has been tested. For sensors with
millivolt output this range can generally be extended to at least twice the range specified with
only minor degradation to specifications. For amplified output sensors the range can be extended
only ten percent before the output is "railed" to the output voltage limit.
Output Span: Is the output voltage for the specified operating pressure range. For sensors
without internal voltage reference the span is ratiometric to the supply voltage of the sensor.
Changes in the supply voltage to the sensor with result in a change in output span for the
pressure applied. The span is the difference in output voltage at full scale pressure from the
offset voltage.
Over-Pressure Maximum: The maximum normal mode (measured) pressure that can be
applied without changing the transducer's performance or accuracy beyond the specified limits.
This would be applied to either port of a differential transducer. This is also called "proof
pressure".
Overall Accuracy Calibrated: The combined error band relative to the BSL with forced
reference unique to one specific transducer. It excludes offset and sensitivity calibration errors. It
includes all other offset and span errors: temperature, repeatability, stability, linearity and
hysteresis.
Overall Accuracy Interchangeable: The combined error band relative to an ideal transducer
response characteristic. It excludes stability errors because stability error is already included in
specified calibration error. It includes all other offset and span errors: calibration, temperature,
repeatability, linearity and hysteresis.
Proof Pressure: is the maximum pressure that may be applied to the sensor without causing any
changes in performance to the specifications.
Reference Pressure: The pressure used as a reference in measuring transducer errors.
Reference Temperature: The temperature used as reference in measuring transducer errors.
Repeatability: The error band expressing the ability of the transducer to reproduce an output
signal parameter (such as offset or span), at specified pressures and temperature, after exposure
to any other pressure and temperature within the specified range.
Sensitivity: The ratio of output signal voltage change to the corresponding input pressure
change. Sensitivity is determined by computing the ratio of span to the specified input pressure
range.
Sensitivity Calibration: The error band defined by the maximum error in calibrating sensitivity.

6-1

Span: The arithmetic difference in transducer output signal measured at the specified minimum
and maximum operating pressures.
Span Error: The normal mode error band defined by the maximum deviation of span from its
specified value. It may include sensitivity calibration temperature, linearity, hysteresis,
repeatability and stability deviations.
Span Repeatability: The error band expressing the ability of a transducer to reproduce its span,
measured at 25C, after exposure to any other pressure and temperature within the specified
range.
Span Temperature Coefficient: The error band defined by the maximum deviation of the span
as the temperature is varied from 25C to any other temperature within the specified range.
Span Stability: The error band expressing the ability of the transducer to maintain the span
voltage at any pressure within the specified range with temperature held constant.
Stability: The error band expressing the ability of a transducer to maintain the value of an output
parameter (such as offset or span) with constant temperature and pressure inputs.
Temperature Coefficient (TC): The error band resulting from maximum deviation of a
transducer output parameter (such as offset or span) as temperature is varied from 25C to any
other temperature within the specified range. It is usually measured in (ppm/C or V/V/C).
Vacuum: A perfect vacuum is the absence of gaseous fluid.
Vacuum Range: The range of absolute pressures between a perfect vacuum (0 psia) and one
standard atmosphere (14.697 psia).
Vacuum Transducer: A transducer scaled for pressure measurement in the vacuum range. This
is usually an absolute transducer, but sometimes a gage transducer.
Worst-Case Error: The error band obtained by simple addition of all applicable errors specified
for the transducer.

6-1

0.3937

0.53525

1.4223 x 10-2

1.9337 x 10-2

14.696

406.79

393.71

0.40147

0.01450

14.223

4.0147

0.14504

408.225.4314

Atmosphere
(standard)

kgf/cm2

13.595

1.000

27.681

in. H2O
(at 39.2F)

0.4912

3.6126 x 10-2

in. H2O
(at 39.2F)

in. Hg
u
(at
32F)
M
Kilopascal
U
(Pa = N/m2)
L
T
Millibar
I
P
cm H2O
L
(at 4C)
Y mm Hg (at 0C)
u
(Torr)

1.000

Pounds Per
Square Inch

Pounds Per
Square Inch

TO OBTAIN u

1.0133 x 102

98.0665

0.13332

0.09806

0.100*

1.000

3.3864

0.2491

6.8948

Kilopascal
(Pa = N/m2)

1.0133 x 103

9.8067 x 102

1.3332

0.9806

1.000

10.000*

33.864

2.491

68.948

Millibar

info@allsensors.com

29.921

28.959

3.9370 x 10-2

2.8958 x 10-2

0.02953

0.2953

1.000

7.3554 x 10-2

2.036

in. Hg
(at 32F)

(Most commonly used - per international conventions; * = exact conversion factor)

Pressure Unit Conversion Constants

6-2

7.600 x 102

7.3556 x 102

1.000

0.7355

0.75006

7.5006

25.400*

1.8683

51.715

mm Hg (at 0C)
(Torr)

1.0332

1.000

1.3595 x 10-3

1.0 x 10-3

1.0197 x 10-3

1.0197 x 10-2

3.4531 x 10-2

2.54 x 10-3 *

7.0307 x 10-2

kgf/cm2

www.allsensors.com

1.033 x 103

1.000 x 103

1.3595

1.000

1.01973

10.1973

34.532

2.5400*

70.309

cm H2O
(at 4C)

1.000

0.9678

1.3158 x 10-3

9.678 x 10-4

9.8692 x 10-4

9.8692 x 10-3

3.342 x 10-2

2.458 x 10-3

6.805 x 10-2

Atmosphere
(standard)

all sensors

Você também pode gostar