Você está na página 1de 4

Cytospin 4 Cytocentrifuge

Product Description

Processes 12 specimens at one time


Accepts all protocols from Cytospin 1, 2 and 3
Allows for one-handed opening and closing with a redesigned lidrelease mechanism
Enables viewing of the sealed head through the polycarbonate window
during operation
Protects mechanical and electronic components from damage due to
accidental fluid spills
Designed for easy disinfection
Meets stringent IEC 61010 safety standards

Protects Users and Specimens

Allows loading of the sealed head inside a microbiological cabinet for


ultimate safety
Features an auto-locking, plastic outer lid
Operates only when lid is locked and keeps lid locked during rotation
Includes disposable sample chambers with caps and a wipe-clean
control panel
Sounds an audible alarm when the cytocentrifuge is out of balance,
outside the speed tolerance or if the lid is not properly locked
Uses specimen safety alarms at one-minute intervals to remind users
to remove specimens to prevent air drying and ensure consistent
results

Provides Excellent Presentation

The cytocentrifuge deposits cells onto a clearly defined area of a glass


slide and allows for the absorption of the residual fluid into the sample
chamber's filter card
Cytocentrifugation constructively flattens cells for excellent nuclear
presentation
During operation, the instrument's spinning action tilts the Shandon
Cytofunnels upright and centrifuges cells onto the deposition area of
the slide, giving all cell types equal opportunity for presentation
In the Load or Stop position, the tilting feature reduces cell loss by
preventing residual fluid from coming into contact with the prepared
slide
Offers Simple and Precise Controls

Pull-out program card logs up to nine programs for fast, convenient


retrieval
Protected program memory stores up to 23 routines for instant recall
and protects from power loss
Easy-touch program keypad allows for easier keystrokes and more
intuitive programming
Speed window displays programmed spinning speeds from 200 to
2000rpm
Three acceleration-control buttons allow the operator the flexibility to
protect fragile samples
Time window displays the programmed and remaining run time from 1
to 99
Control feature has a standby power-saving mode; displays are also
turned on and off by the standby key

Physical Specifications
Dimensions (W x D x H):

With closed lid: 16 x 9.5 x 24.5 in. (40.5 x 24 x 62cm)


With open lid: 16 x 25 x 24.5 in. (40.5 x 62.5 x 62cm)
Weight: 26.5 lb. (12kg)
Power Requirements: 100-240 VAC, 50/60Hz, 1Ph, 150VA Max.

ANALYSIS OF
URINE AND BODY
FLUIDS

Bless Marie B. Andaya

BSMT 3-2
Maam Isolde M. Quitan
F2

Você também pode gostar