Você está na página 1de 4

Appendix B: Dead Load

Table B-1: Roof Level (concrete slab)


Roof
Steel deck, 18 gage
Slab (150mm)
Cement finish
Waterproofing
Ceiling
Gypsum board
Suspended steel channel
Mechanical duct allowance
Plumbing/ Electrical
Total
Parapet (4 CHB)

Load

Unit

0.14
23.5(0.15) = 3.53
1.53
0.07

kPa
kPa
kPa
kPa

0.008(12.7) = 0.10
0.10
0.20
0.10
5.77
1.44(0.9) = 1.30

kPa
kPa
kPa
kPa
kPa
kN/m

Table B-2: All Floors


Uniform Load (kPa)
Floor and floor finishes
Steel deck, 18 gage
Slab (150mm)
Cement finish
Ceramic or quarry tile
Waterproofing

0.14
23.5(0.15) = 3.53
1.53
1.10
0.07

Ceiling
Gypsum board
Suspended steel channel
Mechanical duct allowance
Plumbing/ Electrical allowance

0.008(12.7) = 0.10
0.10
0.20
0.10
6.87

Total
Table B-3: All Floors
Floor and floor finishes
Steel deck, 18 gage
Slab (150mm)
Cement finish
Ceramic or quarry tile
Waterproofing

Ceiling
Gypsum board
Suspended steel channel

Uniform Load (kPa)

Unit

0.14
23.5(0.15) = 3.53
1.53
1.10
0.07

kPa
kPa
kPa
kPa
kPa

0.008(12.7) = 0.10
0.10

kPa
kPa

0.20
0.10
6.87
1.44(3.10) = 4.46

Mechanical duct allowance


Plumbing/ Electrical allowance
Total
Partition (4 CHB)

kPa
kPa
kPa
kN/m

Appendix C: Live load


Table C-1: Roof level
Uniform Load (kPa)
Roof live load (flat or rise less than
33.3% slope)
Deck

1.00
1.90

Table C-2: Third & Fourth Floors


Uniform Load (kPa)
2.40
0.50
Total
2.90

Office
Partitions and interior walls

Table C-3: Second floor


Uniform Load (kPa)
4.80
0.50
Total
5.30

Dining area
Partitions and interior walls

Table C-4: First floor


Basic floor area
Partitions and interior walls

Uniform Load (kPa)


4.80
0.50
Total
5.30

Appendix D: Earthquake Load


Design Considerations
*Based on actual Geotechnical Investigation Report provided by TERMS Concrete &
Materials Testing Laboratory.
Occupancy category = IV (Standard Occupancy); Importance factor, I = 1
Seismic zone = 4; Seismic zone factor, Z = 0.4
Distance to seismic zone = 6 km
Seismic source type = A (active and capable of producing magnitude 7.0)
Near source factor: Na = 1.2, Nv = 1.6

Soil profile type = SD (very dense soil and soft rock)


Seismic coefficient: Ca = 0.528Na; Cv = 1.024Nv
Ct = 0.0731 (for concrete)
Overstrength factor, R = 8.5 (special RC moment frames, NSCP 2010 table 208-11A)
Valley Fault System
Appendix D: Wind Load
Design Considerations
*The design shall conform to Section 207 WIND LOADS of NSCP 2010
Laguna Area (zone 2)
Basic wind speed, V = 200kph
Occupancy category = IV (Standard Occupancy); Importance factor, Iw = 1
Surface roughness = C (207.5.6.2 Surface Roughness Categories, NSCP 2010)
Exposure category = C (207.5.6.3 Surface Roughness Categories, NSCP 2010)
Appendix E: Load Combinations
U = 1.4D
U = 1.2D + 1.6L
U = 1.2D + 1.0L 1.0E
U = 0.9D 1.0E
U = 1.2D + 1.6W +1.0L
Where:
D = dead load
L = live load
E = earthquake load
W = wind load
Appendix E: Foundation Scheme
A. Settlement. The site has no issue on settlement.
B. Liquefaction.
o High water table and low SPT blowcount at the upper layers.
o The site may have an issue on liquefaction
C. Shallow foundation

Embedment Depth
Net Allowable Bearing Capacity
1.5 m
120 kPa
2.0 m
140 kPa
*above value already incorporates factor of safety of 3.0
Tie beams should be incorporated
= 26degrees
Poissons Ratio = 0.40
= 18 kN/m3
ES = 20 MN/m2
o c = 15 kPa
o
o
o
o
o

Você também pode gostar