The Red Book

FIRE & ACOUSTIC DESIGN GUIDE

Including Green Building Systems


November 2011

You can be sure with CSR


CSR is a leading diversified manufacturing company with operations throughout
Australia as well as Asia and New Zealand. For more than 150 years, CSR has
been famous for the certainty built in to the companys range of leading products
and services.
Gyprock plasterboard and Cemintel fibre cement sheet products are proudly
made in Australia.

Sustainability
CSR produces a range of energy efficient building products and systems which
have the potential to reduce heating and cooling costs of homes and buildings,
essentially saving tonnes of greenhouse gases each year. Many of these
products are also produced from recycled materials thus:
Reducing the demand for raw materials
Lowering emissions and pollution during manufacturing
Saving land-fill space.

CSR Guarantee
CSR Building Products guarantees its Gyprock products to be free of defects
in materials and manufacture.
If a CSR product does not meet our standard, we will, at our option, replace or
repair it, supply an equivalent product, or pay for doing one of these.
CSR recommends that only products, components and systems recommended
by it be used. If this is not done, CSR will need to be satisfied that any defect
in its product is attributable to our failure to meet our standard (and not another
cause) before this guarantee applies.
This guarantee excludes all other guarantees and liability for damage or loss
in connection with defects in CSR's product, other than those imposed by
legislation.

A2

The Red Book

Introduction

Steel Stud Wall Systems

Timber Stud Wall Systems

Masonry Wall Systems

Ceiling Systems

Services Systems

Flanking Path Systems

Junctions & Penetrations

Index

The Red Book

IN
A3

How to Use The Red Book

System Index
Inside back cover

Section Index Page A3


A section index is provided
on page A3. The Red
Book is divided into
9 sections with colour
coded stripes at the side
and bottom of each page.
The section letter and
section page number is
provided at the bottom of
each page.

Introduction

Steel Stud Wall Systems

Timber Stud Wall Systems

Masonry Wall Systems

Ceiling Systems

Service Systems

Flanking Path Systems

Junctions & Penetrations

Index to Systems
System
N
005
010
015
025
032
035
039
040
043
044
045
046
050
055
060
061
062
075
080
089
090
091
092
093
110
121
122
123
125
126
127
128
129
131
135
150
152
155
165
167
168
170
171
175
178
179
180
185
186
192
193
194
195
196
197
198
206
207
208
212
216
217
218
222
223
225

An index of all systems


is provided on the inside
back cover and adjacent
page. Here all systems
are listed in numerical
order with a page number
reference.

IN

Index

A3

The Red Book

Page
N
B10
B10
B10
B10
B10
B10
B11
B12
B14
B14
B14
B14
B12
B12
B27
B27
B27
B12
B12
B29
B29
B29
B29
B29
B22
B33
B33
B33
B22
B34
B34
B34
B34
B22
B22
B23
B23
B23
B36
B36
B36
B37
B37
B23
B37
B37
B23
B35
B35
B38
B38
B38
B38
B38
B38
B38
B15
B15
B15
B16
B16
B15
B15
B17
B17
B17

System
N
226
230
231
235
240
241
243
244
248
249
250
255
275
280
290
291
292
293
294
295
296
297
298
305
310
315
320
325
330
335
350
352
354
355
375
380
390
391
392
393
403
410
411
415
419
425
430
450
455
475
480
493
494
495
496
497
498
500
501
502
503
506
507
508
509
510

Page
N
B17
B18
B18
B18
B19
B19
B19
B19
B31
B31
B15
B16
B16
B16
B24
B24
B24
B24
B25
B25
B26
B25
B26
C6
C6
C6
C6
C6
C6
C7
C7
C7
C7
C7
C8
C8
C16
C16
C16
C16
C15
C15
C15
C15
C15
C13
C13
C13
C13
C13
C13
C23
C23
C23
C23
C23
C23
C11
C11
C11
C11
C12
C12
C12
C12
B20

System
N
512
513
515
516
520
521
522
523
526
527
528
530
531
532
533
534
535
540
541
542
543
544
545
548
549
550
551
555
575
580
582
600
601
605
606
610
611
613
614
630
631
632
652
653
654
660
661
662
663
664
665
670
671
672
674
675
677
678
680
681
682
690
693
694
695
696

Page
N
B20
B20
B20
B20
B21
B21
B21
B21
D12
D12
D12
D12
D12
D12
D12
D12
D12
D10
D10
D10
D10
D11
D11
D10
D11
C9
D11
C9
C9
C9
C9
B11
B11
B11
B11
B13
B13
B13
B13
B23
B22
B22
C7
C8
C8
C8
C14
C14
C14
C14
C8
C14
C14
C14
C10
C10
C9
C9
C10
C10
C10
C21
C21
C22
C22
C21

System
N
697
698
722
723
724
730
731
732
737
738
739
760
761
762
763
764
765
766
767
768
769
774
775
776
777
778
779
780
781
783
784
787
788
795
796
797
798
801
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
829
831
832

Page
N
C22
C22
D16
D16
D16
D16
D16
D16
D6
D7
D7
D6
D6
D6
D6
D6
D6
D6
D7
D7
D7
D8
D8
D8
D8
D9
D9
D8
D8
D8
D8
D9
D9
D17
D17
D17
D17
E6
E6
E6
E6
E6
E6
E6
E6
E7
E7
E7
E7
E7
E7
E7
E7
E7
E7
E6
E8
E8
E8
E8
E8
E8
E8
E8
E9
E9

System
Page
N
N
833
E9
834
E9
835
E9
836
E9
837
E9
838
E9
839
E9
841
E10
845
E10
846
E10
847
E10
848
E10
849
E10
851
E14
852
E14
853
E14
856
E14
857
E14
858
E14
859
E14
860
E15
862
E13
863
E13
864
E13
865
E16
866
E16
867
E13
868
E13
870
E12
871
E12
874
E13
875
E13
876
E13
877
E16
878
E16
890
E19
891
E15
892
E15
893
E15
894
E15
900
C17
901
C17
902
C17
903
C17
911
C18
912
C18
915
C18
916
C18
920
C20
921
C20
923
C20
924
C20
925
C20
927
C20
928
C20
940
B32
940+
B32
ExpressWall
941
B32
942
B32
945
B28
946
B28
947
B28
950
E12
951
E12
952
E12

System
N
953
955
958
959
967
968
969
970
971
972
981
982
983
985
986
987
992
993
994
995
997
75PP
75PP-DC
75SS
75SS-DC
Hebel
Powerwall
001
Hebel
Powerwall
Hebel
Powerwall
PF-001
SS01
SS02
SS04
SS08
SS09
SS10
SS11
SS12
SS13
SS17
SS18
SS19
SS20
SS21
SS22
SS23
SS24
SS26
SS30
SS31
SS32
SS33
SS34
SS38
SS39
SS40
SS41
SS42
SS44
SS45
SS46

IN1

System Tables Sections B, C, d, e & F

Page
N
E12
E12
E11
E11
B31
B31
B31
B30
B30
B30
E17
E17
E17
E17
E17
E18
E18
E18
E18
E18
E18
D13
D13
D14
D14
D15
B35
C19
E11
F4
F4
F4
F5
F5
F5
F5
F5
F5
F5
F6
F6
F6
F6
F6
F6
F6
F6
F7
F7
F7
F7
F7
F7
F7
F8
F8
F8
F4
F4
F4

The Red Book

Steel Frame Internal Wall Systems Single Stud


SYSTEM SPECIFICATION

System number and icon illustration.

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 010a shown)

PKA-052

Lining material as per system table.


Steel Studs at 600mm maximum centres.

Check for appropriate fire rating (FRL) if required.

NOTES:

Lining material as per system table.

Acoustic performance valid for studs 0.50 BMT.

Check for appropriate acoustic performance (Rw/Rw+Ctr) if required.


Acoustic performance values are provided via a matrix of options.

FRL

STUD DEPTH mm

SYSTEM
N

Report/Opinion

WALL LININGS

51

BOTH SIDES

//

1 x 10mm GYPROCK
Plasterboard CD.

CSR 010

Check System Specifications for elements common to the systems.

BOTH SIDES

//

1 x 13mm GYPROCK
Plasterboard CD.

SIDE ONE
1 x 13mm GYPROCK
AQUACHEK Plasterboard.

//

Check the typical layout illustration for the basic system format.

CSR 015

Acoustic Opinion or Test references information.

//

(c) 75 GW Partition 11kg

(d) TSB3/ASB3 Polyester

Check for alternative systems on the same and adjacent pages.

SYSTEM SPECIFICATION

Relevant selection and design information is provided at the beginning of each


section. Installation layouts are shown at the back of sections (where applicable).

200mm minimum cavity.

(c) 75 GW Partition 11kg

(d) TSB3/ASB3 Polyester

90

102

118

176

35/27 37/30 37/30 38/31 41/34

(b) 50 GW Partition 11kg

39/29 41/32 42/33 43/34 45/36

(c) 75 GW Partition 14kg

44/35 44/35 45/36 47/38

39/31 40/33 41/34 42/35 44/37

WALL THICKNESS mm

42/32 43/33 44/34 46/36

77

90

102

118

176

(a) Nil

38/30 39/32 40/33 42/35 45/38

(b) 50 GW Partition 11kg

43/33 44/35 45/36 47/38 49/40

2 x 13mm GYPROCK
Plasterboard CD.

(e) 60 Soundscreen 1.6

46/37 46/37 48/39 50/41

43/35 43/36 44/37 46/39 48/41

WALL THICKNESS mm

45/35 46/36 48/38 50/40

90

103

115

131

189

(a) Nil

35/28 37/30 38/31 40/33 43/37

(b) 50 GW Partition 11kg

40/31 42/33 43/34 45/36 47/39

(c) 75
GW Partition
11kg
TYPICAL
LAYOUT
(d) TSB3/ASB3 Polyester

44/35 44/35 ACOUSTIC


46/37 48/40
OPINION
40/33 41/34 42/35 44/37
46/40

(e) 60 Soundscreen 1.6

43/33 44/34 46/36 48/39


PKAA031

WALL THICKNESS mm
84
96
112
170
Rondo71
DUO Two-way
Steel angle to
Steel Grid Ceiling
support ceiling grid
(a) Nil
37/30 38/31 40/33 41/34 44/38
System
100mm
min 11kg
42/33insulation
43/34 45/36 46/37 48/40
System insulation (b) 50 GW Partition
System

1x 13mm GYPROCK
50mm
/ / Bradford Glasswool Partition batts
SOUNDCHEK
11kg/m3 to extent specified in table.
plasterboard.

Wall with required sound rating.

The Red

41/31 42/32 43/33 45/35

77

(a) Nil

(d) TSB3/ASB3 Polyester

Ceiling lining as per system table.

170

42/33 42/33 43/34 45/36

39/31 39/32 40/33 41/34 43/36

(e) 60 Soundscreen 1.6

SIDE TWO

BOTH SIDES

112

39/29 40/31 41/32 42/33 44/35

(c) 75 GW Partition 14kg

CSR 032
Floor or roof structure.

96

(b) 50 GW Partition 11kg

(e) 60 Soundscreen 1.6

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

84

34/26 35/28 36/29 37/30 40/33

1 x 13mm GYPROCK
Plasterboard CD.

BOTH SIDES

38/27 39/29 41/31 43/33

71

(a) Nil

1 x 13mm GYPROCK
Plasterboard CD.

CSR 025

39/29 39/30 41/32 43/34

36/28 36/28 37/30 39/32 41/34

(e) 60 Soundscreen 1.6

(d) TSB3/ASB3 Polyester

Flanking Paths via Ceiling

150

36/26 37/27 38/29 40/31 42/33

SIDE TWO

SIDE ONE

92

31/23 32/24 33/26 35/28 38/31

(b) 50 GW Partition 11kg

WALL THICKNESS mm

CSR 011

76

Rw / Rw+Ctr

(a) Nil

WALL THICKNESS mm

Check System Lining details.

64

CAVITY INFILL
(Refer to Section A)

CSR 005

(c) 75 GW Partition 11kg

(d) TSB3/ASB3 Polyester

45/36 46/37 47/38 49/41

42/35 42/35 44/37 45/38 47/41

(e) 60 Soundscreen 1.6

GYPROCK
Panel
Ceiling
System

WALL THICKNESS mm

44/34 46/36 47/37 49/40

77

90

102

118

176

B9

Book
EXTENT OF INSULATION

SYSTEM N

CEILING LININGS

1200mm each side


of the wall

Nil

Entire Ceiling

Rw

CSR FP01

Flanking Path Systems Section G

(a) Gyprock plasterboard panel 10mm

38

44

(b) Ecophon 20mm Focus A, Ds or E 20mm

21

24

25

(c) Ecophon 20mm Focus Glasswool Panels + plasterboard


panels 10mm

42

48

49

(d) Ecophon Master A 40mm

30

31

31

(ef) USG Radar, Impressions, Olympia Micro 15mm


(f) USG Mars, Millenia 19mm

System number details.

SYSTEM SPECIFICATION

45

30-35

30-36

30-36

35

35-36

35-36

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

Check the typical layout illustration for the appropriate system format.

System insulation

Floor or roof structure.


200mm minimum cavity.

100mm
min

System insulation

Ceiling Framing

50mm Bradford Glasswool Partition batts


11kg/m3 to extent specified in table.
Ceiling lining as per system table.
Wall with required sound rating.

Check for appropriate acoustic performance (Rw/Rw+Ctr if required).


Acoustic performance values are provided via a matrix of options.
Check System Lining details.

Acoustic Opinion or Test references information.

NOTE: Junction may be


finished square, with
stopping bead or with
cornice. Do not rigidly
fix cornice to walls
where friction joints are
used

Refer to typical wall and ceiling junction details.


Refer to typical penetration details.

Fix track at each


main runner

(b) 1 x 13mm GYPROCK Plasterboard panel.

43/34

(c) 1 x 13mm GYPROCK FYRCHECK Plasterboard

46/38

1500mm max.

Entire Ceiling

48/39

53/45

55/47

59/51

60/52

Promaseal IBS backing58/50


54/46

59/51

55/47

60/52

rod 20% larger diameter


than gap (gap 15-30mm)

59/51

G3

J-Track

10mm dia. MS rod


fixed to slab and
support angle

1400mm max.

Stud

50/41

52/44

(e) 2 x 13mm GYPROCK FYRCHECK Plasterboard

RONDO P50 or P60


Shadowline Stopping
Bead (finish as
required)
Fix wall sheets at 10
to15mm below head
track flanges

(f) 2 x 16mm GYPROCK FYRCHECK Plasterboard

Mechanical fire
damper tested and
approved for
AS1530.4

Track section with


32mm flange fastened
to soffit at 600mm
centres max.

47/38

49/40

J-Track fixed to studs

(d) 1 x 13mm + 1 x 16mm


GYPROCK FYRCHECK Plasterboard

The Red Book

Main Runner

6 10mm
clearance to
GYPROCK
plasterboard

Damper seal angles


75mm x 50mm x
1.2mm MS

NOTE: This method of


construction is not
recommended for studs
adjacent to windows or
doors or studs carrying
loads greater than
0.25kPa.

Support angle 50mm


x 50mm x 5mm MS
1 or 2 layers GYPROCK
FYRCHEK Plasterboard
as per FRL
GYPROCK Shaft
Liner Panel

FIG Z002: DEFLECTION HEAD

FIG Z005: HEAD FOR SUSPENDED CEILING


Additional Furring Channel
where wall runs parallel to
setout

Suspended Ceiling
Top Cross Rail

FIG Z028: TYPICAL INTUMESCENT FIRE DAMPER


Refer to manufacturer for assessment number and installation details.
20mm gap
100mm max.
(do not fix
through track)
NOTE: Stopping bead
or cornice finish as
required. Do not rigidly
fix cornice to walls
where friction joints are
used

Fix cornice to
ceiling only with
Gyprock Cornice
Cement

Furring
Channel

Stud

Fix Head Track to Furring


Channel at 600mm max.
centres

Fix wall sheets at 10


to15mm below head
track flanges

Deflection Head Track


fastened at 600mm
centres max.

Stud

Where wall runs


perpendicular to furring
channel fix track to furring
at each intersection

Steel studs at
600mm centres

FIG Z006: WALL BASE DETAIL


STEEL STUD WALL SYSTEM

Fix track at 600mm max.


centres. With 150mm width
track, use 2 fixings
approximately 20mm in
from each side of track
Fill gap with CSR Gyprock
Sealant for acoustic
integrity

Stud

Rondo angles
mechanically
fixed to studs

GYPROCK
FYRCHEK
plasterboard

Proprietary
intumescent
damper

Spigot to terminate
with break joint

Proprietary extruded
aluminium track

Stud

Steel studs
at 600mm
centres

Finish as required

Fix extruded track at


each furring channel

GYPROCK plasterboard
ceiling fixed to furring
channel at appropriate
centres

Z2

Furring Channel in
normal setout position

Flexible Mastic

FIG Z003: HEAD USING ALUMINIUM HEAD TRACK

A4

CSR FP02

Fill gap with CSR


Gyprock Sealant for
acoustic integrity

1200mm each side


of the wall
Rw / Rw+Ctr

FIG Z004: HEAD FOR


SUSPENDED TEE-LOCK CEILING

Stud
6mm
clear
of
soffit

Nil

41/32

FIG Z027: INSTALLATION DETAIL FOR FIRE DAMPER IN SHAFT WALL SYSTEM APPRAISAL: CSIRO FCO 2109

Note: Wall/ceiling intersection details require engineers approval where seismic loads are expected.

100mm max.
to first fastener
(Do not fix
through track)

CEILING LININGS

(a) 1 x 10mm GYPROCK Plasterboard panel.

Non-Fire Rated Applications

Check System Specifications for elements common to the systems.

Junctions & Penetrations Section Z

EXTENT OF BUILDING BLANKET


SYSTEM N

Head & Base Details


FIG Z001: FRICTION FIT HEAD

Tape and set or


cornice finish

GYPROCK
plasterboard
ceiling

GYPROCK
plasterboard
Perimeter gaps sealed

Studs bottomed
in track

Steel studs
at 600mm
centres

10mm max. gap


at bottom of sheet

The Red Book

Z22

The Red Book

The Red Book

Section A
Introduction

Contents

The Red Book

An Introduction to The Red Book

A6

Components

A6 A15

Product Properties

A15 A16

Material & Construction Standards

A16

Fire Testing

A17

Lining Design

A18 A20

Building Acoustics

A21

Building Acoustics in Practice

A22 A23

Definitions

A24

A5

Introduction to
The Red Book

The Red Book Fire & Acoustic Design Guide provides a


ready reference to the performance of an extensive range of
CSR Gyprock and Cemintel fire and acoustic systems.
Over the last 60 years, CSR has developed effective,
practical and cost effective fire and acoustic systems for
most applications. Fire, acoustic and structural testing
has been carried out for all plasterboard and fibre cement
products, as well as those of CSR Bradford Insulation,
CSR Hebel and Rondo Building Products. To complement
this extensive testing program, CSR has obtained certified
assessments from appropriate authorities on the likely
performance of some systems. These assessments are
based on test results and expert opinion.
CSR Gyprock and Cemintel fire rated systems have been
tested or assessed to AS1530.4 : 1997 or 2005 at approved
testing laboratories.
CSR has developed systems with Fire Resistance
Levels (FRL) up to /180/180 (3 hours). The systems and
performance specifications detailed in this manual are
guaranteed only for the construction specified. Any variation
or substitution of materials or assembly requirements, or
any compromise in assembly may result in failure under
critical conditions. It is recommended that only accredited
plasterboard fixers install fire rated systems.
CSR Gyprock and Cemintel are continuously developing
products, which may result in changes to product
specifications, range and performance. The systems and
products in this Fire and Acoustic Design Guide are current
at the publication date.
Gyprock plasterboard lining products are manufactured
to AS2588 - Gypsum Plasterboard, and Cemintel fibre
cement products are made to AS2908.2 - Cellulose Cement
Products.

Components
CSR manufactures and supplies a diverse range of
plasterboard and fibre cement sheets, acoustic panels
and accessories to suit a multitude of wall, ceiling and
encasement applications.
Gyprock Plasterboard Cd is composed of a gypsum
core encased in a heavy duty linerboard. Available with long
edges recessed (RE) to assist in producing a smooth, even
and continuous surface once jointed, in square edge (SE),
and in combination RE/SE. Gyprock Plasterboard CD
incorporates Controlled Density (CD) technology. Gyprock
Plasterboard CD is suitable for internal walls and ceilings.
Gyprock Supaceil is a 10mm thick sheet designed
to span up to 600mm in ceiling applications. Gyprock
Supaceil is composed of a gypsum core encased in a
heavy duty linerboard. Long edges are recessed for flush
jointing. Gyprock Supaceil incorporates CD (Controlled
Density) technology.
Gyprock Soundchek has been designed to provide
increased acoustic resistance in wall and ceiling systems.
Gyprock Soundchek is composed of a high density
gypsum core encased in a heavy duty linerboard. Long
edges are recessed to assist in producing a smooth, even
and continuous surface once jointed. Gyprock Soundchek
is suitable for internal walls and ceilings.
Gyprock Impactchek is high strength plasterboard
designed for impact areas. It is composed of a glass fibre
reinforced gypsum core plus a fibreglass mesh bonded to
the inside of the back face. 13mm IMPACTCHEK is encased
in a violet linerboard and has equivalent fire and acoustic
performance to 13mm Fyrchek. The long edges of both
are recessed for flush jointing.
Gyprock Aquachek is designed for use in lining the
walls of wet areas of residential and commercial buildings.
It is a gypsum plasterboard with a core treated to make it
resistant to moisture and humidity. It is manufactured to
satisfy the requirements of AS2588 Gypsum Plasterboard.
It is encased with light blue linerboard and the long edges
are recessed.
Gyprock Fyrchek can be used in wall and ceiling
systems where an FRL is to be achieved, or where acoustic
performance is required. Gyprock Fyrchek is composed
of a specially processed glass fibre reinforced gypsum core
encased in a heavy duty pink liner board.
Gyprock FyrchekMR is primarily intended for walls and
ceilings in wet area rooms and for soffits and external walls
that must achieve fire resistance. Gyprock Fyrchek MR is
composed of a specially processed glass fibre reinforced
gypsum core which is treated in manufacture to withstand
the effects of moisture, and encased in a heavy duty light
blue liner board.

A6

The Red Book

Superchek
Gyprock Superchek is 10mm plasterboard with a very
dense core and heavy duty facing. It has an impact resistance
designed to withstand the knocks typical of residential
buildings, and has excellent sound resistance. It spans
600mm on ceilings and has a white paper face to assist
paint coverage.

Gyprock Plasterboard Panels


Gyprock Plasterboard Panels have a gypsum core and
various face treatments. Gyprock Panels are produced
to fit metric grid specifications of (600 x 1200mm nominal).
Perforated Panel has a white vinyl face finish, and a regular
grid of 6mm full depth holes. Perforations are approximately
10% of the panel area, and combined with suitable insulation,
provide a medium level of acoustic absorption.
FIG A2: GYPRoCk PeRFoRATed PANeL dIMeNSIoNS.

EC08 Partition is an economical, non-fire rated board for


general areas where acoustic requirements are not high.
EC08 Fire is the original GECA certified EC08 board with
fire and acoustic rating for party walls and meeting rooms.
EC08 Impact is fire and acoustic rated with impact resistance
for high traffic areas such as hallways and stairs in education
and health facilities. All products in the range have been
certified by GECA as meeting the requirements of their
environmental standard for Panel Boards.
Gyprock Flexible Plasterboard has been designed
for curved wall and ceiling systems and has an enhanced
core to enable bending to a small radius. It is composed of
a gypsum core encased in a heavy duty linerboard. Long
edges are recessed to assist in producing a smooth, even
and continuous surface once jointed. Gyprock Flexible
Plasterboard is 6.5mm thick and is installed in two layers.
CeminSeal Wallboard is an autoclaved, cellulose fibre
reinforced cement sheet that is immune to permanent
water damage and has high impact resistance. Ceminseal
Wallboard is suitable for internal walls as well as internal
and external ceiling applications. It has a recess on both
long edges so that sheets may be flush jointed, using CSR
jointing materials.
Gyprock Perforated Plasterboard has been designed for
use on walls and ceilings where additional sound absorption
is required. It is composed of a gypsum core encased in a
heavy duty linerboard and incorporates CD technology. Long
edges are recessed for flush jointing. Perforations total 8.2%
of the sheet area. For detailed pattern information, refer to
Section E.

530mm

eC08 Range

590mm

Gyprock Shaft Liner Panel is a 25mm thick sheet


composed of a glass fibre reinforced gypsum core encased
in a heavy duty linerboard. Gyprock Shaft Liner Panel is
used to enclose lift shafts, stairwells and service shafts in
multistorey construction. Gyprock Shaft Liner Panel can be
used to achieve fire resistance in wall and ceiling systems.

1130mm
1191mm

Supatone is a paper faced white ceiling tile suited to basic


commercial ceilings. A low maintenance bright white panel,
it can be wiped clean with a damp cloth.
Freshtone diamond White has a lightly textured vinyl
surface which resists fading and mould growth. With a white
finish, it is suitable for shopping centres, factories and offices.
Acoustic Wall and Ceiling Panels
CSR provides a range of acoustic ceiling and wall products
through the Fricker Comprador division. The range includes
mineral fibre and glasswool ceiling panels, metal pan ceiling
panels, and glasswool wall panels. Brands include Ecophon,
USG, Daiken, Fricker and Comprador.
The products have a variety of physical properties to assist
in their specification, including Noise Reduction Coefficient
(NRC), Ceiling Attenuation Class (CAC), Light Reflectance
(LR), colour and edge profile. These and other properties
are listed in Section E.
CSR Fricker Comprador supplies fully integrated ceiling
solutions including suspension systems, ceiling tiles, lights,
diffusers and perimeter trims.
For more information call 1300 374 253.

1200mm

FIG A1: PeRFoRATIoN PATTeRN

3600mm

The Red Book

A7

Gyprock Cornice
CSR Gyprock manufactures six popular machine made
cornice profiles to cater for many styles and applications.
Please refer to Table A1 in this section for general product
information.

eclipse ClimaPlus
19mm thick mineral
fibre panels with three
edge options.

GYPRoCk
CoVe CoRNICe

GYPRoCk
JAZZ CoRNICe

GYPRoCk
SYMPhoNY CoRNICe

GYPRoCk
CoNCeRTo CoRNICe

GYPRoCk
TeMPo CoRNICe

GYPRoCk
CLASSIC CoRNICe

Impressions
ClimaPlus
15mm thick mineral
fibre panels with three
edge options.

Mars ClimaPlus
19mm thick mineral
fibre/glasswool
panels with three
edge options.

olympia Micro
ClimaPlus
15mm thick mineral
fibre panels with three
edge options.
GYPRoCk ShAdoWSeT

A8

The Red Book

Gyprock Plasterboard Range

CeminSeal Wallboard Range

TABLe A1: GYPRoCk PRoduCT WeIGhTS

TABLe A2: CeMINSeAL WALLBoARd PRoduCTIoN


SIZeS ANd ToLeRANCeS

Colour shading behind each product approximates the


colour of the product face liner sheets. For detailed sheet
sizes and availability, contact the CSR Gyprock Sales Centre
in your region.
Thickness

Mass

mm

kg/m2

10
13
10
13
10
10
13
10
13
13
10
13
13
13
6.5
13
16
13

6.5
8.5
6.5
8.5
6.5
7.2
13.0
8.0
10.4
10.3
10.4
9.3
10.5
12.1
4.25
10.5
12.5
10.7

16

13.5

PERFORATED SHEET

13

10.0

SHAFT LINER PANEL

25

19.8

Gyprock Cornice Products

Size

Gyprock Lining Products


CD RECESSED EDGE
CD SQUARE EDGE
CD RECESSED EDGE/SQUARE EDGE
SUPACEIL
SOUNDCHEK
AQUACHEK
IMPACTCHEK
SUPERCHEK
EC08 PARTITION
EC08 FIRE
EC08 IMPACT
FLEXIBLE
FYRCHEK
FYRCHEK MR

COVE CORNICE
CLASSIC CORNICE
TEMPO

CORNICE

CeminSeal Wallboard has two long edges recessed to


allow seamless jointing.
Thickness
(6mm RE = ) (9mm RE = ) (12mm RE = )
Length
(mm)

Width (mm)
900

1800
2400

1350

2700
3000

1200

3600

4200

Mass 6mm thickness (nominal)

9.7kg/m2

Mass 9mm thickness (nominal)

14.3kg/m2

Mass 12mm thickness (nominal)

18.8kg/m2

Length

+0 to -4mm

Width

+0 to -3mm

Thickness

+0.25 to -0.25mm

Diagonals Difference (max)

3mm

Mass
kg/m2

55

0.7kg/m

70

0.9kg/m

90

1.3kg/m

90

1.2kg/m

90

1.8kg/m

SYMPHONY CORNICE

75

0.9kg/m

CONCERTO CORNICE

90

1.6kg/m

JAZZ CORNICE

75

1.8kg/m

SHADOWSET

105

1.0kg/m

The Red Book

CeminSeal Wallboard is manufactured in the following sizes


and available in all states.

A9

Steel Components

Stud Adhesive

CSR recommends steel building elements manufactured by


Rondo Building Services Pty Ltd, for our systems.

Gyprock Acrylic Stud Adhesive is coloured blue for easy


identification. It can be used on both timber and steel in
temperatures not less than 5C.

General information on Rondo steel building components is


provided throughout this manual. Additional information can
be obtained from the Rondo Building Services Pty Ltd office
in your state, or telephone 1300 367 663.

CSR Gyprock Resilient Mount


The CSR Gyprock Resilient Mount is a proprietary
component used in conjunction with Rondo steel sections for
fastening Gyprock
plasterboard
to a supporting
structure while
simultaneously
i s o l a t i n g i t f ro m
structure bor ne
vibration.
This significantly reduces the amount of impact noise, speech
and low frequency sound filtering through to rooms above,
below or alongside the noise generating room. The resilient
mount has been design for use on ceilings and can be
used on walls provided plasterboard with minimum mass of
12.5kg/m2 is fixed on the resilient mount side of the wall. The
mount can be used in fire rated and non-fire rated systems.

A10

Contact surfaces must be free of oil, grease or other foreign


materials before application. The adhesive is applied with a
broad knife to form 25mm diameter by 15mm high walnuts.
T h i s p ro d u c t
is suitable for
use with prepainted metal
battens and
some treated
t i m b e r s .
Always follow
directions on
packaging
when using
CSR stud
adhesive.

Masonry Adhesive
Gyprock Masonry Adhesive is used to adhere Gyprock
plasterboards to concrete and all masonry substrates.

The Red Book

Jointing Accessories & Compounds

Mastics & Sealants

CSR has a wide range of compounds, cements and


accessories for finishing plasterboard installations.

Gyprock Fire Mastic must be used in fire rated systems


where caulking is indicated and is recommended for caulking
acoustic systems.

Refer to the Gyprock Residential Installation Guide,


NGYP547 for detailed jointing and finishing information.

Gyprock Wet Area Acrylic Sealant is recommended for


sealing non-fire rated wet area systems.

Fasteners
CSR Gyprock distributes a comprehensive range of ring
shank nails, hot-dip galvanised clouts, and screws for
use with timber and steel framing to accommodate most
installation applications. For exterior applications, refer to the
appropriate installation guide.

The Red Book

A11

TABLe A3: FIxING PLASTeRBoARd To SoFTWood


Plasterboard
Thickness

1st Layer

2nd Layer

3rd Layer

6.5mm
Plasterboard

2.8x40mm Gal Clout or


2.8x25mm Ring Shank Nail or
Type S #6-18 x 25mm NP Screw

2.8x40mm Gal Clout or


2.8x30mm Ring Shank Nail or
Type S #6-18 x 32mm NP
Screw

10mm
Plasterboard

2.8x40mm Gal Clout or


2.8x30mm Ring Shank Nail or
Type S #6-18 x 25mm NP Screw (on wall)
Type S #6-18 x 30mm NP Screw (on ceiling)

2.8x50mm Gal Clout or


Type S #6-18 x 40mm NP
Screw

13mm
Plasterboard

2.8x40mm Gal Clout or


2.8x30mm Ring Shank Nail or
Type S #6-18 x 32mm NP Screw

2.8x50mm Gal Clout or


Type S #6-18 x 45mm NP
Screw

3.75x75mm Gal Clout or


Type S #8-15 x 65mm NP Screw or
#10x40mm Laminating Screw

16mm
Plasterboard

2.8x50mm Gal Clout or


Type S #6-18 x 32mm NP Screw

3.15x65mm Gal Clout or


Type S #6-18 x 50mm NP
Screw

3.75x75mm Gal Clout or


Type S #8-15 x 65mm NP Screw or
#10x40mm Laminating Screw

13mm + 16mm
Plasterboard

2.8x40mm Gal Clout or


2.8x30mm Ring Shank Nail or
Type S #6-18 x 32mm NP Screw

2.8x50mm Gal Clout or


Type S #6-18 x 45mm NP
Screw

TABLe A4: FIxING PLASTeRBoARd To hARdWood


Plasterboard
Thickness

1st Layer

2nd Layer

3rd Layer

6.5mm
Plasterboard

2.8x30mm Gal Clout or


2.8x25mm Ring Shank Nail or
Type S #6-18 x 25mm NP Screw

2.8x30mm Gal Clout or


2.8x25mm Ring Shank Nail or
Type S #6-18 x 32mm NP
Screw

10mm
Plasterboard

2.8x30mm Gal Clout or


2.8x25mm Ring Shank Nail or
Type S #6-18 x 25mm NP Screw (on wall)
Type S #6-18 x 30mm NP Screw (on ceiling)

2.8x40mm Gal Clout or


Type S #6-18 x 32mm NP
Screw

13mm
Plasterboard

2.8x30mm Gal Clout or


2.8x25mm Ring Shank Nail or
Type S #6-18 x 32mm NP Screw

2.8x40mm Gal Clout or


Type S #6-18 x 45mm NP
Screw

3.15x65mm Gal Clout or


Type S #8-15 x 65mm NP Screw or
#10x40mm Laminating Screw

16mm
Plasterboard

2.8x40mm Gal Clout or


Type S #6-18 x 32mm NP Screw

2.8x50mm Gal Clout or


Type S #6-18 x 45mm NP
Screw

3.15x65mm Gal Clout or


Type S #8-15 x 65mm NP Screw or
#10x40mm Laminating Screw

13mm + 16mm
Plasterboard

2.8x30mm Gal Clout or


2.8x25mm Ring Shank Nail or
Type S #6-18 x 32mm NP Screw

2.8x50mm Gal Clout or


Type S #6-18 x 45mm NP
Screw

TABLe A5: FIxING FIBRe CeMeNT ANd PLASTeRBoARd To TIMBeR


Lining Thickness

1st Layer

6mm Wallboard

2.8x40mm Gal Clout or


Type S #8-15 x 20mm NP Screw

2nd Layer

9mm Wallboard

2.8x40mm Gal Clout or


Type S #8-15 x 30mm NP Screw

13mm Plasterboard +
6/9mm Wallboard over

2.8x40mm Gal Clout or


2.8x30mm Ring Shank Nail or
Type S #6-18 x 32mm NP Screw

2.8x50mm Gal Clout or


Type S #8-15 x 40mm NP Screw

16mm Plasterboard +
6/9mm Wallboard over

2.8x50mm Gal Clout or


Type S #6-18 x 32mm NP Screw

2.8x50mm Gal Clout or


Type S #8-15 x 40mm NP Screw

6mm Wallboard +
13/16mm Plasterboard over

2.8x40mm Gal Clout or


Type S #8-15 x 20mm NP Screw

2.8x50mm Gal Clout or


Type S #6-18 x 45mm NP Screw

9mm Wallboard +
13/16mm Plasterboard over

2.8x40mm Gal Clout or


Type S #8-15 x 30mm NP Screw

2.8x50mm Gal Clout or


Type S #6-18 x 45mm NP Screw

NOTES:
Type 'W' screws of equivalent length may be used as an alternative to Type S NP when fixing to timber only.
Predrill 9mm and 12mm Wallboard for easier fixing.
Fixings are suitable for internal applications only.
NP
= Needle Point Screws.
DP
= Drill Point Screws.
GAL = Galvanised.

A12

The Red Book

TABLe A6: FIxING PLASTeRBoARd To STeeL 0.5 0.8mm BMT


Plasterboard Thickness

1st Layer

2nd Layer

6.5mm Plasterboard

Type S #6-18 x 25mm NP Screw

Type S #6-18 x 25mm NP Screw

3rd Layer

10mm Plasterboard

Type S #6-18 x 25mm NP Screw

Type S #6-18 x 40mm NP Screw

13mm Plasterboard

Type S #6-18 x 25mm NP Screw

Type S #6-18 x 40mm NP Screw

Type S #8-15 x 65mm NP Screw or


#10x40mm Laminating Screw

16mm Plasterboard

Type S #6-18 x 30mm NP Screw

Type S #6-18 x 45mm NP Screw

Type S #8-15 x 65mm NP Screw or


#10x40mm Laminating Screw

13mm + 16mm
Plasterboard

Type S #6-18 x 25mm NP Screw

Type S #6-18 x 45mm NP Screw

TABLe A7: FIxING PLASTeRBoARd To STeeL 0.8 2.4mm BMT


Plasterboard Thickness

1st Layer

2nd Layer

3rd Layer

6.5mm Plasterboard

Type S #6-18 x 25mm DP Screw

Type S #6-18 x 25mm DP Screw

10mm Plasterboard

Type S #6-18 x 25mm DP Screw

Type S #6-18 x 40mm DP Screw

13mm Plasterboard

Type S #6-18 x 25mm DP Screw

Type S #6-18 x 40mm DP Screw

#10x40mm Laminating Screw

16mm Plasterboard

Type S #6-18 x 30mm DP Screw

Type S #6-18 x 45mm DP Screw

#10x40mm Laminating Screw

13mm + 16mm
Plasterboard

Type S #6-18 x 25mm DP Screw

Type S #6-18 x 45mm DP Screw

TABLe A8: FIxING FIBRe CeMeNT ANd PLASTeRBoARd To STeeL 0.5 0.8mm BMT
Lining Thickness

1st Layer

6mm Wallboard

Type S #8-15 x 20mm NP Screw or


FibreZIPS M5-18 x 20mm

2nd Layer

9mm Wallboard

Type S #8-15 x 30mm NP Screw or


FibreZIPS M5-18 x 30mm

6mm Wallboard +
13/16mm Plasterboard over

Type S #8-15 x 20mm NP Screw or


FibreZIPS M5-18 x 20mm

Type S #6-18 x 40mm NP Screw

9mm Wallboard +
13/16mm Plasterboard over

Type S #8-15 x 30mm NP Screw or


FibreZIPS M5-18 x 30mm

Type S #6-18 x 40mm NP Screw

13mm Plasterboard +
6/9mm Wallboard over

Type S #6-18 x 25mm NP Screw

Type S #8-15 x 40mm NP Screw

16mm Plasterboard +
6/9mm Wallboard over

Type S #6-18 x 30mm NP Screw

Type S #8-15 x 40mm NP Screw

TABLe A9: FIxING FIBRe CeMeNT ANd PLASTeRBoARd To STeeL 0.8 2.4mm BMT
Lining Thickness

1st Layer

2nd Layer

6mm Wallboard

Type S #8-15 x 20mm DP Screw

9mm Wallboard

Type S #8-15 x 30mm DP Screw

6mm Wallboard +
13/16mm Plasterboard over

Type S #8-15 x 20mm DP Screw

Type S #6-18 x 40mm DP Screw

9mm Wallboard +
13/16mm Plasterboard over

Type S #8-15 x 30mm DP Screw

Type S #6-18 x 40mm DP Screw

13mm Plasterboard +
6/9mm Wallboard over

Type S #6-18 x 25mm DP Screw

Type S #8-15 x 40mm DP Screw

16mm Plasterboard +
6/9mm Wallboard over

Type S #6-18 x 30mm DP Screw

Type S #8-15 x 40mm DP Screw

NOTES:
Predrill 9mm and 12mm Wallboard for easier fixing.
Fixings are suitable for internal applications only.
NP
= Needle Point Screws.
DP
= Drill Point Screws.
GAL = Hot-Dip Galvanised.

The Red Book

A13

Insulation Materials

Wall System Thermal Performance

CSR Fire and Acoustic Systems incorporate CSR Bradford


glasswool and rockwool insulation. These products
have undergone significant acoustic testing and have
a proven track record of performance and durability in
service. Additional information on CSR Bradford Insulation
materials is available by telephoning CSR Bradford on
1300 850 305.

Timber and steel stud external walls in this manual include


thermal ratings expressed as Rt(win) and Rt(sum), to represent
Total R-values for the Winter and Summer design conditions
as required by the BCA.

Although insulation materials are often specified for


thermal resistance, they can contribute significantly to the
acoustic performance of wall and ceiling systems. CSR
only recommends materials that have been tested for fire
and acoustic applications, have proven durability, and are
supported by their manufacturer for these applications.
Should other insulation materials be used, the manufacturer
of those materials must verify the performance of the
complete system, CSR will not support the performance of
substitute materials.
Acoustic Polyester insulation manufactured by Tontine and
Autex have been tested in acoustic applications by the
manufacturer and are specifically made for that purpose. CSR
accepts the use of Tontine and Autex Polyester insulation.

The Total R-values presented are based on assessments


c a r r i e d o u t i n a c c o rd a n c e w i t h t h e m e t h o d s o f
AS/NZS4859.1 amdt 1:2006 (Materials for thermal
insulation of buildings - Part 1: General criteria and technical
provisions). Any included bulk insulation is a CSR Bradford
product that has a material R-Value compliant with the
standard, and building elements have thermal values sourced
from the AIRAH handbook. No allowance has been made
for thermal bridging from the structural members. Thermal
performances quoted are based on an assessment through
the insulation path.
The contribution to Total R-values depends on installation,
workmanship and environmental conditions and it is
assumed that cavities that are ventilated.

TABLe A10: SPeCIFIed INSuLATIoN ANd ABBReVIATIoNS


(Abbreviated names have been used in system tables).
Product

Abbreviation

25mm Bradford Fibertex 450 80kg/m3

25 Fibertex 450

45mm Bradford Rockwool Partition batts 38kg/m3


60mm Bradford

Soundscreen

45 Rockwool Partition batts

R1.6 wall batts (Rockwool)

35kg/m3

75mm Bradford Soundscreen R2.0 wall batts (Rockwool) 32.5kg/m3


88mm Bradford

Soundscreen

R2.5 wall batts (Rockwool)

40kg/m3

60 Soundscreen 1.6
75 Soundscreen 2.0
88 Soundscreen 2.5

120mm Bradford Soundscreen R3.0 floor / ceiling batts (Rockwool) 30kg/m3

120 Soundscreen 3.0

50mm Bradford Glasswool Partition batts 11kg/m3

50 GW Partition 11kg

75mm Bradford Glasswool Partition batts 11kg/m3

75 GW Partition 11kg

110mm Bradford Glasswool Partition batts 11kg/m3

110 GW Partition 11kg

11kg/m3

165 GW Partition 11kg

165mm Bradford Glasswool Partition batts

50mm Bradford Glasswool Partition batts 14kg/m3

50 GW Partition 14kg

14kg/m3

75 GW Partition 14kg

75mm Bradford Glasswool Partition batts

100mm Bradford Glasswool Partition batts 14kg/m3

100 GW Partition 14kg

75mm Bradford Gold Batt R1.5 wall batts (Glasswool) 8.8kg/m3

75 Gold Batts 1.5

75mm Bradford Gold Batt R2.0 wall batts (Glasswool) 18.0kg/m3

75 Gold Batts 2.0

90mm Bradford Gold Batt R2.0 wall batts (Glasswool 10.5kg/m3

90 Gold Batts 2.0

34.0kg/m3

90 Gold Batts 2.7

90mm Bradford Gold

Batt

R2.7 wall batts (Glasswool)

140mm Bradford ceiling Gold Batt R2.5 (Glasswool) 6.4kg/m3

140 Gold Batts 2.5

Batt

6.7kg/m3

165 Gold Batts 3.0

215mm Bradford ceiling Gold Batt R4.0 (Glasswool) 6.9kg/m3

215 Gold Batts 4.0

Tontine TSB 2 (50mm) / Autex ASB 2 (50mm) Polyester Insulation

TSB2/ASB2 Polyester

Tontine TSB 3 (65mm) / Autex ASB 3 (60mm) Polyester Insulation

TSB3/ASB3 Polyester

Tontine TSB 4 (75mm) / Autex ASB 4 (70mm) Polyester Insulation

TSB4/ASB4 Polyester

Tontine TSB 5 (85mm) Polyester Insulation

TSB5 Polyester

Tontine Blanket (25mm) 10kg/m3 Polyester Insulation

TBL/1025 Polyester

38mm Bradford Masonry Wall Blanket (HP Glasswool)

Masonry Wall Blanket R1.2

165mm Bradford ceiling Gold

A14

R3.0 (Glasswool)

The Red Book

TYPICAL BRAdFoRd INSuLATIoN PRoduCTS

For wet area walls and external ceilings subject to intermittent


high humidity where plasterboard is specified, Gyprock
Aquachek or Gyprock FyrchekMR or CeminSeal
Wallboard are recommended. In all cases follow product
installation brochures.

Thermal Performance
Gyprock and Cemintel products have been tested to
ASTM C518 for thermal performance.
The R values for Gyprock plasterboards are:
10mm plasterboard = 0.04 0.05 m2K/W.
13mm plasterboard = 0.05 0.07 m2K/W.
16mm plasterboard = 0.07 0.09 m2K/W.
The R values for Cemintel products are:
6mm fibre cement = 0.02 m2K/W.
7.5mm fibre cement = 0.03 m2K/W.
9mm fibre cement = 0.03 m2K/W.

Product
Properties
Thermal & Moisture Stability
Gyprock plasterboard and Cemintel fibre cement
products are stable building materials when subjected to the
normal range of interior temperature and humidity conditions.
Thermal coefficient of Linear Expansion ().
Plasterboard: =16.2 x 10 -6 mm (mm/C) in the
temperature range 4C to 38C.
Fibre cement: = 7.5 x 10-6/C.
Final length is calculated as follows:
Lf = Li (1 + T).
The hygrometric coefficient of expansion ().
P l a s t e r b o a rd : = 7 . 2 x 1 0 -6 m m / m m / % R . H .
(5% 90% R.H.). Final length is calculated as follows:
Lf = Li (1 + RH).
Fibre cement: = 0.18% (expansion from equilibrium to
saturated). Final length is calculated Lf = Li x x (% of
saturation).

Internal Moisture
Gyprock plasterboard must not be used where it will be
in contact with liquid water or an atmosphere of constant
relative humidity above 90%.
Gyprock Plasterboard CD, Gyprock Supaceil and
Gyprock Soundchek are designed for use in dry areas only.

The Red Book

A15

Fire hazard Properties

Combustibility

The BCA limits the materials used in Class 2 to 9 buildings


by controlling the Fire Hazard properties of linings. These
properties are assessed using AS/NZS3837 cone calorimeter
test.

In accordance with BCA Clause C1.12, plasterboard and


fibre cement sheet may be used wherever a non-combustible
material is required by the Code.

Please refer to Table A11 for Gyprock plasterboard and


Cemintel product performance details. Contact Fricker
Comprador for properties of other acoustic wall and ceiling
products.
TABLe A11: FIRe hAZARd PRoPeRTIeS

Material &
Construction
Standards

CSR Product

ASEA
m2/kg

Group
Number

Report

10 13mm Plasterboard CD

<250

10mm SUPACEIL

<250

All materials and procedures shall comply with the following


standards where applicable, and all additional details
contained in Gyprock and Cemintel Technical Literature.

10 13mm SOUNDCHEK

<250

Plasterboard Manufacture:

10 13mm AQUACHEK

<250

AS/NZS2588 : Gypsum plasterboard.

6.5mm FLEXIBLE

<250

Plasterboard Installation:

13mm Perforated Sheet

<250

13 16mm FYRCHEK

<250

MR

<250

25mm SHAFT LINER PANEL

<250

10mm SUPERCHEK

<250

13mm

IMPACTCHEK

<250

13mm

ECO8

<250

13mm ECO8 Fire

<250

13mm ECO8 Impact

<250

CeminSeal Wallboard

<250

13mm Perforated Panels

<250

10mm
Diamond White

<250

10mm SUPATONE

<250

10 13mm Unpainted Panel

<250

Ecophon ADVANTAGE

<250

Ecophon FOCUS

<250

Mars

<250

Eclipse

<250

Impressions

<250

Olympia Micro

<250

13 16mm FYRCHEK

Partition

FRESHTONE

AS/NZS2589 : Gypsum linings in residential and light


commercial construction Application and Finishing.
Plasterboard and Fibre Cement in Wet Areas:
AS3740 : Waterproofing of Wet Areas Within Residential
Buildings.

NOTES:
ASEA = Average Specific Extinction Area
WFRA 45759
FAR 2781
FH 3619
FH 3621
FH 3623

A16

The Red Book

Fire Testing
Fire resistance testing is conducted to the Australian
Standard AS1530 part 4 Fire Resistance Tests of Elements
of Building Construction.
This standard gives the test method and criteria of failure for
the various elements of construction such as partition walls,
floor/ceilings and roof/ceilings.

The common regulatory FRL requirements are:


Non-Loadbearing

Loadbearing

/30/30

30/30/30

/60/60

60/60/60

/90/90

90/90/90

/120/120

120/120/120

/180/180

180/180/180

For Example: /120/120.

The specimen assemblies are built into the test furnace


and subjected to furnace temperatures in accordance with
AS1530.4 Standard Time vs Temperature Curve.

The dash indicates no requirement for Structural


Adequacy, which applies to all non-loadbearing systems.

FIG A3: STANdARd TIMe vs TeMPeRATuRe CuRVe

The second 120 indicates Insulation for 120 minutes.


For any specified FRL, a system having equal or higher
respective criteria may be used. Some systems have
multiple FRLs stated. FRLs expressed as /y/z relate to
non-loadbearing walls; FRLs expressed as x/y/z relate to
loadbearing walls; or FRLs expressed as x/y/z* relate to walls
with additional design limits.

1200
1100

TEMPERATURE (C)

The first 120 indicates Integrity for 120 minutes.

1000
900
800

What is Resistance to the Incipient


Spread of Fire?

700
600

Ceiling systems may be required to achieve a Resistance to


the Incipient Spread of Fire.

500
0

30

60

90

120 150 180 210 240 270 300 330 360


TIME (minutes)

how the Specimen is Assessed


The test specimen is heated in the prescribed manner until
the failure criteria has been reached, or is terminated by
agreement between parties.
Assessment criteria are represented by three performance
measurements known as Fire Resistance Levels (FRL).

This requires the ceiling to provide adequate thermal


insulation to prevent combustibles in a roof/ceiling or floor/
ceiling cavity from igniting for the specified time.
The Building Code of Australia requirement for some ceiling
systems is to provide Resistance to the Incipient Spread of
Fire (RISF), into the space above itself, for not less than 60
minutes. Systems that meet this requirement are indicated
in the system tables.

Structural Adequacy

Fire hazard Properties

Failure occurs when the specimen collapses under load.

Fire hazard properties of wall and ceiling linings in some


classes of building are specified by the BCA. Refer to Table
A11 for fire hazard properties of CSR products.

Integrity
Failure occurs when the specimen develops cracks or
openings through which flames or hot gases can pass.
Insulation

Smoke Proof Walls

Failure occurs when the average temperature of the


unexposed surface of the specimen increases by more than
140C above the initial temperature, or the temperature at
any point of the unexposed surface increases by more than
180C above the initial temperature.

Smoke proof walls are required in some Class 9a


buildings, and they must be built from non-combustible
materials where they do not require an FRL. Steel framed
wall systems clad with Gyprock Plasterboard CD
(eg. CSR 010) may be used.

The test performance of the specimen is expressed as a Fire


Resistance Level, which indicates the number of minutes for
which the specimen fulfils the requirements of the three fire
test criteria. These numbers are then rounded down to the
nearest regulatory requirement.

Fire rated smoke proof walls should be selected from the


steel framed systems (refer to Section B) with an appropriate
FRL.

All systems in this guide with a stated FRL have been


assessed by Registered Testing Authorities, including CSIRO,
BRANZ and Exova Warrington Fire.

The Red Book

Smoke proof walls required for Class 9c buildings may use


steel or timber framing with linings of 13mm Gyprock
Plasterboard CD or CeminSeal Wallboard. Refer to systems
CSR 010, 654 and 310.

A17

Lining Design
There are a number of methods for ensuring that plasterboard
linings meet end user expectations. For best results, these
should be considered in the planning stages of a project and
be clearly set out in specifications and contract documents.
It is noted in the plasterboard standard AS/NZS2589.1
Gypsum linings Application and Finishing that it is good
practice to construct a reference area of decorated work
to aid in judging quality of walls and ceilings throughout a
project.

Levels of Finish
A Level of Finish sets out the minimum specifications for
installation processes from framing preparation to lining
decoration. The levels are defined in AS/NZS 2589.1, and are
intended to provide builders, installers and their customers
with defined methods and practices necessary to meet the
customers expectations in terms of the Level of Finish.
It is essential to determine the level of finish required before
the frame construction begins, as specific tolerances are
required for frame alignment as well as for plasterboard fixing
and finishing for each of the levels of finish. Unless these
requirements are met throughout construction, it may not be
possible to attain the desired finish level without extensive
corrective measures.

In general, walls and ceilings should be specified to Level


4 Finish unless a higher or lower level of finish is required.
Complete details for a Level 4 Finish are set out in Gyprock
Residential Installation Guide No. GYP 547.
A Level 5 Finish should be used wherever gloss or semi-gloss
paints are to be used, where paint is mid or dark coloured, or
where critical light conditions occur such as from windows,
skylights, or silhouette and spot lighting.
Installation is similar to Level 4 Finish with the addition of
a skim coat which is used to remove differential surface
textures and porosity. Skim coating refers to a thin finish
coat, rolled, trowelled or airless sprayed and then possibly
sanded, to achieve a smooth and even finish. It is normally
less than 1mm in thickness and is applied over the entire
surface to fill imperfections in the joint work, smooth the
paper texture and provide a uniform surface for decorating.

Critical Light
The impression of flatness of plasterboard is influenced by
factors such as the accuracy of the substrate, the fixing
methods, joint formation and finishing textures. A surface
that appears perfectly flat in one lighting condition can
seem uneven in another. Any imperfection or undulation in
a completed lining installation can become obvious under
critical or glancing light, where the incident light from an
artificial or natural source is nearly parallel to the surface.

FIG A4: PRoCeSS FoR deTeRMINING APPRoPRIATe LeVeL oF FINISh

DECORATION

Finish Not Important


or Undecorated

Wall covering,
Wallpaper or Texture

Paint

Flat/Matt/Satin/
Low Sheen

Pastel/
Mid-tones

Critical & Non-critical


Lighting

Level 3 Finish

A18

Level 4 Finish

Non-critical
Lighting

Semi-gloss/Gloss

Dark tones

Critical
Lighting

Critical & Non-critical


Lighting

Level 5 Finish

The Red Book

To minimise the effect of critical lighting from artificial lighting


sources:
Locate fluorescent lights about 450mm below the ceiling
to give a more even distribution of light.
Use more lights at regular spacings to give an even,
diffused light.
Recess light fittings into a ceiling.
Allow a generous angle of incidence to the surface for
feature lighting, such as spotlights, to minimise the
highlighting of imperfections.
Do not use up-lights or unshaded light sources close to a
wall or ceiling.
To minimise natural lighting problems, particularly from direct
sunlight:
Avoid placing windows immediately adjacent to the end
of a wall.
Do not take window glazing up to ceiling level.
Provide sun shades over windows.

FIG A5: TYPICAL GLANCING LIGhT SITuATIoNS

Applied Finish Specification


Finishes applied to plasterboard surfaces can have a
significant effect on the perceived quality of the installation,
particularly where critical lighting conditions exist. The
difference in texture and absorption characteristics between
the body of the sheet and joints may show through thin and
low quality paint coatings. Recommended paint systems
consist of one coat of a plasterboard sealer followed by two
coats of finishing paint.
Always follow the manufacturers instructions for application
and recoating. For best results, specify that coatings are
applied with a roller to achieve a full even coat and a light,
uniform texture over the entire surface.
General rules when specifying an applied finish are:
Textured or heavy patterned finishes tend to hide
imperfections.
Matt finishes minimise imperfection visibility.
Semi-gloss and gloss finishes highlight imperfections.
Light colours are less likely to show imperfections and
impact damage. They are also more effective at diffusing
light and reducing shadow effects, particularly in smaller
rooms.
Gloss paints tend to highlight paint application variations
(e.g. where a good wet edge has not been maintained
when painting).
Paint applied with a longer pile roller tends to mask
imperfections better than those applied with a short pile
roller.

Glancing light

Jointing

Shadow zone

Shadow zone

Jointing

Glancing light

Wall mounted light

The Red Book

A19

Resistance to Impact

Curved Walls and Ceilings

Wall lining materials may be selected for properties relating


to resistance to damage. These properties include bending
strength (resistance to static load), soft body impact
resistance (resistance to damage from people impact,
measured with a swung sand bag), and surface damage
resistance (resistance to indent from small, solid objects).
Refer to Table A12 for a selection of linings and relative
performance for the various properties.

Gyprock plasterboard can be curved for installation


on walls and ceilings that have appropriately designed
framing. Maximum frame spacing for curved walls is reduced
compared to straight walls, and can be found in the relevant
installation manuals.

TABLe A12: STReNGTh ANd IMPACT PRoPeRTIeS

TABLe A13: MINIMuM RAdIuS FoR CuRVed WALLS

Lining

Bending
Strength

Soft Body
Impact
Resistance

Surface
Damage
Resistance

10mm Superchek

13mm Impactchek

10mm Gyprock
plasterboard CD

13mm EC08
Impact
6mm CeminSeal
Wallboard

Note: More s indicates higher performance.

Gyprock plasterboard of 10mm and 13mm thickness


provide adequate resistance to soft body impacts likely in
domestic or light commercial use respectively.
Walls lined with Gyprock Fyrchek , Impactchek and
CeminSeal Wallboard can meet various requirements of
Specification C1.8 of the Building Code of Australia 2004.
This clause specifies resistance to Uniform Distributed Loads
(UDLs), surface indentation and impact from a weighted
sand bag that is dropped from a specified height.

The minimum curvatures for a range of products are listed


in Table A13. Note that Gyprock Flexible plasterboard is
6.5mm thick and is always used in two layers.

Plasterboard Lining

Minimum Radius
(Concave)

Minimum Radius
(Convex)

6.5mm Flexible
Plasterboard

450 mm

250 mm

10mm plasterboard
CD

900 mm

900 mm

13mm plasterboard
CD and 10mm
Supaceil

1000 mm

1000 mm

13 & 16mm Fyrchek

3m

3m

13mm Perforated
Plasterboard sheet

20m

20m

FIG A6: FRAMING PRePARATIoN FoR CuRVed WALL


uSING RoNdo FLexI-TRACk
Refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide for
maximum stud spacings.

Rondo Flexi-Track

Minimum curving radius for


Rondo Flexi-Track.
Track
Minimum
Depth
Radius
51mm
180mm
64mm
200mm
76mm
230mm
92mm
285mm
150mm
475mm

FIG A7: CuRVed CeILING FRAMING


Curved Furring Channel

Ceiling Framing

Curved Gyprock plasterboard

A20

The Red Book

Building
Acoustics
Building acoustics can be separated into sound absorption
and sound transmission.
Sound absorption relates to control of sound that is generated
within a room and how it affects people in that room.
Sound transmission relates to sound that passes through a
dividing element (direct sound, controlled by the elements
sound insulation), and through the surrounding structure
(indirect or flanking transmission).
Methods of controlling noise in buildings can be based on
systems, structure and lining materials and their absorption
and transmission properties.
CSR recommends that an acoustic engineer be consulted
for all projects where acoustics are important.

Flanking Transmission

Sound Impact Ratings


The BCA has performance requirements relating to sound
impact for floors and some walls.
For floors, this is specified as a maximum value such as:
Lnw+CI = 62. Note that lower values of Lnw+CI indicates
better acoustic impact performance. Queensland and
Northern Territory have no requirements for impact rating
of floors.
Walls may be required to meet the definition of Discontinuous
Construction. This means that wall leaves must be separated
by at least 20mm and no mechanical connection is permitted,
except that masonry may have resilient ties.
Systems that meet this specification are noted in the
appropriate system specifications.
FIG A8: CoMMoN FLANkING TRANSMISSIoN PAThS
1. Ceiling plenums, floors, walls.
2. Poor seals between structural
elements and around service
penetrations.
3. External air-borne paths.

Flanking sounds reach adjoining areas by indirect paths,


rather than through the dividing element. The perimeter
junction of walls, floors and ceilings that surround the
dividing element are the main paths for flanking transmission.
Other paths include open windows, ducts, doorways and
suspended ceilings.
Noise sources that have a high degree of low frequency
noise such as traffic, aircraft and DVD sound systems have
potential for transmission through the building structure.
Transmission of this type of noise follows structural load
paths and can be controlled by breaking these load paths
or providing complete separation of the structure.

4. Heating and ventilation ducting.


5. Rigid plumbing connections and
penetrations.
6. Back-to-back cabinets and
switches/power outlets.

1
1

4
2

2
3

6
4

2
3

6
5
1

Noise sources that generate a high amount of mid and


high frequency noise, such as services and speech, tend to
transmit via air paths and direct transmission in lightweight
construction.
Typical problem areas for this type of transmission include
doors and door frames, glazing, suspended ceiling cavities
and ductwork. Practical methods for addressing common
situations within buildings can be seen in Section Z.

The Red Book

A21

Building
Acoustics in
Practice
System Performance
The Rw, Rw + Ctr and Ln,w + CI values in this manual refer to
expected results of a laboratory test on an element.
Extensive testing over many years has been carried out
by CSR at laboratories including the Commonwealth
Experimental Building Station (later CSIRO) at North Ryde
NSW, National Acoustic Laboratory at Lindfield NSW, CSIRO
Laboratories at Highett, Victoria and even, up to 1978, at
our own NATA registered laboratory. Extensive development
testing has been carried out at Rintoul Laboratories, Seven
Hills NSW since 1995, and some of the systems subsequently
validated at other laboratories.
Performance values provided by PKA Acoustic Consulting
use a prediction system based on these tests, and the
system has been updated to include the most current CSR
sponsored testing. The prediction system has been calibrated
against the round robin European test of a standard
plasterboard wall in 24 European acoustic laboratories, and
has successfully predicted the performance of a calibration
wall for an acoustic laboratory in Brisbane.
As testing from different laboratories can vary (the European
24 laboratory test of the standard plasterboard wall was
Rw47 to Rw52), it is possible that laboratory tests may be 1
to 2 Rw points above a prediction.
All care has been taken with preparation of these predictions
and it is assumed that construction is strictly in accordance
with this manual and relevant Gyprock and Cemintel
installation guides.

Acoustic Integrity
The acoustic integrity of a system can be influenced by the
combination of elements that make up the system. Single
leaf and uninsulated systems are more dependant on high
quality installation, as relatively minor defects can cause
major degradation of the system performance.
Building systems that allow defects to be hidden from view
have a higher chance of gaps being left unsealed, making
them more vulnerable to performance degradation.
The likelihood and effect of defects occurring with typical
systems is shown in Table A14.
TABLe A14: ACouSTIC INTeGRITY
Wall System

The BCA specifies deemed to satisfy acoustic values that


are laboratory results, and in some cases allows lower values
when site tested. For example, in a Class 2 building the
separating wall can have Rw + Ctr = 50 (a laboratory result),
or DnT,w + Ctr = 45 (tested on site). The difference of 5 is that
expected between site and laboratory, although it might not
always be the case. CSR recommends that where designers
are selecting systems based on expected site performance,
an acoustic engineer be consulted.

A22

Effect of
Defects on
Performance

High

High Degradation

High

High Degradation

Low

High Degradation

Low

Moderate
Degradation

Low

Low Degradation

Single skin masonry wall

Masonry with stud,


uninsulated

Single stud, uninsulated

Site Performance vs. Laboratory


Performance
As houses are not built like laboratories, it is unlikely that
performance measured in ideal test conditions will be
achieved in a building. Designers should take care to select
systems compatible with the support structure to provide the
desired level of insulation.

Chance of
Gaps Being Left
Unsealed

Single stud, insulated

Double stud, insulated

The Red Book

Background Noise
Low levels of noise transmitted from other areas can be
partially obscured by background noise.
Where the background noise level is low, such as in remote
areas, consideration should be given to providing a higher
than standard level of sound insulation.

Variation in occupant Perception of


Noise
Tolerance for noise varies greatly between people, and
variations of up to 15dB can be considered acceptable.
This means consideration should be given to the occupants
expectation of the internal acoustic environment. Users of
concert halls and practice rooms may have higher acoustic
expectations than guests of inner city hotels.

Minimum Performance Levels for


Internal Walls and Ceilings
The BCA sets out minimum performance levels for internal
walls and ceilings based on acceptable standards for
affordable housing. The performance requirements are in
terms of Rw, Rw+Ctr and Ln,w+CI.
These levels may need to be increased for:
Va r i a t i o n i n o c c u p a n t p e r c e p t i o n s o f n o i s e ,
e.g. high, medium or low cost housing.

Va r i a t i o n i n o c c u p a n t p e r c e p t i o n s o f n o i s e ,
e.g. high, medium or low cost housing.
Background noise levels may be very low.
The lack of simplicity in construction could reduce actual
performance.

Minimum Performance Levels


for external Walls
The BCA does not set minimum performance levels of
transmission for external walls. Guidance should be sought
from an acoustic consultant or local authority for setting
the design requirements of these elements, as they may be
affected by road or aircraft noise.
Issues that may affect the design levels for external walls are:
Va r i a t i o n i n o c c u p a n t p e r c e p t i o n s o f n o i s e ,
e.g. high, medium or low cost housing.
Background noise levels are low.
Flanking transmission of the surrounding structure,
particularly at windows and doors.
The lack of simplicity in construction could reduce actual
performance.

Gaps, Crack and holes

Background noise levels are low.

Small openings allow airborne sound to pass through


an element and can significantly reduce sound insulation
performance. For optimum sound insulation, the element
must be airtight.

Flanking transmission of the surrounding structure.


Lightweight structures can be more prone to low frequency
flanking.

Perimeters and penetrations for services must be sealed with


an acoustic sealant that is capable of accommodating the
expected building movement.

The presence of services will vary which BCA provisions


are applicable, and could mean separate construction is
required.

For systems that are multi-layered, such as masonry


composite systems, each layer must be air tight, as services
such as power points and switches can act as airborne
flanking paths. To remedy this, consider using acoustic rated
power boxes, the Gyprock Silencer, and insulation in the
cavity. Refer to flanking details, Section Z.

Local authorities have higher or additional requirements.

The lack of simplicity in construction could reduce actual


performance.

Minimum Performance Levels


for Services
The BCA sets out minimum performance levels for isolation
of noise from services based on acceptable standards for
affordable housing. The performance levels are in terms of
Rw and Rw+Ctr.
These levels may need to be increased for:
The nature of the noise source and adjacent occupant
activity. Some noises are particularly annoying to
occupants.
Systems that meet the new BCA minimum Rw+Ctr
requirements may have lower performance than systems
that meet the corresponding Rw requirements.

The Red Book

A23

Definitions
Rw Weighted Sound Reduction Index. A measure of
the sound insulation performance of a building element. Rw
is a laboratory measurement similar to STC.
Rw is measured and calculated using the procedures from
AS1276 and AS1191. The related field measurement is
abbreviated as DnT,w.
The higher the number the better the insulation
performance.
dnT,w Weighted Standardised Field Level difference.
A measurement of the sound insulation performance of a
building element. It describes the difference in noise level on
each side of a wall or floor, and indicates the level of speech
privacy between spaces. It is measured in the field and is
therefore subject to the inherent inaccuracies involved in
such a measurement.
The higher the number the better the insulation
performance.
Ctr A spectrum adaptation value used to modify the sound
insulation performance of a wall or floor. Sound insulation
performance can be described by Rw or the DnT,w but these
are not accurate for all noises, especially for low frequency
bass noise from modern stereo systems. Ctr values are
negative value which is added to either the Rw or DnT,w.
AS/NZS1276 - sets out testing methodologies for the sound
insulation properties of building elements and incorporates
these factors and explains their use.
Smaller negative Ctr values are more favourable than large
negative values.
dB(A) The A-scale and dB(A) noise level are used to
degrade the performance of a sound level meter to simulate
what humans hear. The human ear is not a perfect listening
device, it is poor at hearing low frequency noise. dB(A) is
used to compare measured sound with perceived sound.
A number of noise criteria refer to, and are measured in
dB(A). The larger the dB(A) level the louder the noise.
Ln,w Weighted Normalised Impact Sound Pressure
Level. A measure of the noise impact performance of a
floor/ceiling. It is measured in very controlled conditions
in a laboratory and is characterised by how much impact
sound reaches the receiving room via the ceiling/floor from
a standard tapping machine test.

LnT,w Weighted Standardised Field Impact Sound


Pressure Level. A measure of the noise impact performance
of a floor/ceiling. It is similar to Ln,w except it is measured in
the field and is therefore subject to the inherent inaccuracies
involved in such a measurement.
The lower the number the better the performance.
C I A spectrum adaptation term used to modify the
measured impact sound pressure level, Ln,w or LnT,w.
Impact sound is generated by a laboratory grade tapping
machine placed on the floor to be tested. This tapping machine
does not accurately simulate the noise of a persons foot steps
on the floor above, so the CI term was developed to more
closely simulate foot step noise.
The term is defined in ISO717-2. The Ln,w or LnT,w alone
is sufficient to characterise concrete floors covered with
carpet. Other types of floors such as timber joist floors, bare
concrete floors or polished timber or tiles laid on concrete
floors require the CI term to properly characterise footstep
noise.
Timber joist floors can have a CI value slightly positive.
Concrete floors with an effective covering such as carpet
have CI terms approximately equal to 0dB. Concrete floors
with a hard, or less effective covering, can have CI terms
varying between 15dB and 0dB.
NRC Noise Reduction Coefficient. A measure of the
ability of a material to absorb sound.
NRC is generally a number between 0 and 1. A material with
an NRC rating of 1 absorbs 100 % of incoming sound, that
is, no sound is reflected back from the material.
STC Sound Transmission Class. A measure of the
sound insulation performance of a building element used
in the BCA prior to 2000. It is measured in very controlled
conditions in a laboratory.
CAC Ceiling Attenuation Class A single number rating
from a laboratory test to measure sound reduction between
rooms via the ceiling.
dnc,w Weighted Suspended Ceiling Normalised Level
difference. Similar to CAC.
Source: Building Code of Australia, Sound Insulation
Guideline.

The lower the number the better the performance.

A24

The Red Book

Section B

Steel Stud Wall Systems

Contents

The Red Book

Stud Selection Tables


Introduction
Design Considerations
Installation
Components

B2 B4
B4
B4 B6
B6 B7
B7 B8

Internal Wall System Specifications


Single Stud
Rondo Quiet Stud
Staggered Stud
Double Stud
StrataWall
Party Wall
SecurityWall
Resilient Mount
Cinema Wall
Studs Lined One Side
Shaft Wall
Laminated Services

B9 B12
B13
B14 B16
B17 B19
B20 B22
B23 B24
B25 B27
B28
B29
B30 B31
B32
B33 B36

External Wall System Specifications


Steel Cladding
ExpressWall
RendaLine
Cladding On Battens
Texture Base Sheet For Houses
Concrete
Hebel Powerpanel
Masonry

B37
B38 B39
B39 B41
B42
B43
B44
B44
B45

Columns & Beams

B46

ECO8 Internal Wall System Specifications

B47 B52

System Installation Details

B53 B65

B1

Stud Selection Tables


Tables B1 to B8 provide stud selection information suitable for all CSR Gyprock & Cemintel non-fire rated and fire rated
non-loadbearing internal wall systems that are to be designed for a Uniform Distributed Load (UDL) of 0.25kPa, 0.35kPa or
0.50kPa as detailed in each table.
Refer to Rondo for other design pressures and for loadbearing walls.
TABLE B1: MAXIMUM WALL HEIGHT WITH RONDO LIPPED STEEL STUDS NON-LOADBEARING WALLS
WALLS GENERALLY (LOAD = 0.25kPa)
Wall Frame and
Lining Configuration
600mm max. cts

600mm max. cts

300mm 300mm
max. cts max. cts
300mm 300mm
max. cts max. cts
Boxed

Studs

Stud Size
BMT
Linings (mm)
10
13
16
CSR 080(-/180/180)
10
13

0.5

51
0.75

0.5

64
0.75

1.15

2.77
3.20
3.38
2.60
2.32
2.32

2.91
3.32
3.52
2.60
2.60
2.60

3.33
3.72
3.91
3.30
2.72
2.72

3.93
4.22
4.35
3.60
3.13
3.25

4.17
4.43
4.52
4.30
3.53
3.58

16

2.32

2.60

2.75

3.28

3.59

10

2.37

2.83

3.51

10

2.93

3.61

76
0.55 0.75 1.15
Maximum Wall Height (m)
3.70 4.43 4.65
4.13 5.02 5.22
4.30 5.25 5.42
3.80 4.10 5.00
3.20 3.58 4.05
3.24 3.82 4.05
3.25

3.87

4.05

0.55

92
0.75

1.15

150
0.75 1.15

4.54
4.94
5.18
4.40
3.61
3.61

4.83
5.50
5.71
4.80
4.13
4.18

5.11
5.75
5.92
5.00
4.69
4.69

6.55
6.99
7.19
7.00
5.33
5.37

7.22
7.54
7.65
7.65
6.81
6.81

3.61

4.20

4.69

5.37

6.81

TABLE B2: MAXIMUM WALL HEIGHT WITH RONDO LIPPED STEEL STUDS NON-LOADBEARING WALLS
WALLS OF SHAFTS AND FIRE ISOLATED EXITS (LOAD = 0.35kPa)
Wall Frame and
Lining Configuration
600mm max. cts

600mm max. cts

300mm 300mm
max. cts max. cts
300mm 300mm
max. cts max. cts
Boxed

Studs

Stud Size
BMT
Linings (mm)

0.5

51
0.75

0.5

64
0.75

1.15

10

2.42

2.55

2.93

3.49

3.70

3.25

3.81

3.81

13

2.81

2.92

3.29

3.75

3.94

3.65

4.43

16

3.00

3.12

3.45

3.84

3.99

3.78

4.62

92
0.75

1.15

150
0.75 1.15

3.81

3.81

3.81

3.81

3.81

4.60

4.39

4.84

5.06

5.71

5.71

4.77

4.60

5.01

5.20

6.37

6.89

CSR 080(-/180/180)

2.60

2.60

3.30

3.60

4.30

3.78

4.10

4.77

4.40

4.80

5.00

6.37

6.89

10

2.07

2.34

2.34

2.80

3.15

2.76

3.20

3.62

3.06

3.70

3.81

3.81

3.81

13

2.07

2.34

2.34

2.80

3.17

2.76

3.37

3.62

3.06

3.70

4.20

4.83

5.53

16

2.07

2.34

2.34

2.90

3.18

2.76

3.41

3.62

3.06

3.70

4.20

4.83

5.53

10

2.14

2.59

3.15

10

2.65

3.26

NOTES:
Deflection Limit is span/240 to a maximum of 30mm, in accordance
with BCA Specification C1.8.
Tabulated heights do not include axial loads (except self weight) or
shelf loading.
Loadings: Table B1 Pultimate = 0.375 kPa, Pservice = 0.25 kPa.
Loadings: Table B2 Pultimate = 0.525 kPa, Pservice = 0.35 kPa.
Walls are not for external applications.
All loadings in accordance with AS1170:2002.
Walls analysed in accordance with AS4600:1996.
Noggings in accordance with Table B3.
Staggered stud walls use 64mm lipped studs in 92mm track with
Gyprock Staggered Stud Clip.
Tables have been prepared by Rondo Building Services Pty Ltd.

B2

76
0.55 0.75 1.15 0.55
Maximum Wall Height (m)

TABLE B3: MINIMUM NUMBER OF NOGGINGS


Lining Configuration
Lined Both Sides

Lined One Side*


Staggered Studs

Wall Height (m)


0 - 4.4
4.4 - 8.8
0.0 - 3.0
3.0 - 6.0
6.0 - 8.0
All

Number of Noggings
(equally spaced)
0
1
1
2
3
0

NOTE: * Plus noggings at head. Refer to details in Section Z.

The Red Book

TABLE B4: MAXIMUM WALL HEIGHT FOR RONDO QUIET STUD WALLS GENERALLY (UDL = 0.25kPa)
Wall Frame and Lining Configuration

Stud Spacing (m)

Minimum Plasterboard
Thickness (mm)

600

450

10

3.70

4.02

13

4.13

4.41

16

4.30

4.58

Spacing

TABLE B5: MAXIMUM WALL HEIGHT FOR GYPROCK SECURITYWALL SYSTEMS (UDL = 0.25kPa)
Wall Frame and Lining Configuration

Security Panel

Minimum Lining Thickness (mm)

Maximum Wall Height (m)

13mm GYPROCK Plasterboard CD

3.0

13mm GYPROCK FYRCHEK or EC08 FIRE / IMPACT

4.0

13mm GYPROCK Plasterboard CD

3.0

13mm GYPROCK FYRCHEK or EC08 FIRE / IMPACT

5.2

27

50

TABLE B6: MAXIMUM WALL HEIGHT FOR GYPROCK STRATAWALL WITH H-STUDS AT 600mm CENTRES
Wall Type

or

Wind Loading
Pservice
kPa

Maximum Wall Height (m)


25H55 H-Studs at 600mm ctrs

50H55 H-Studs at 600mm ctrs

0.25

3.0

0.25

3.0

or

TABLE B7: MAXIMUM WALL HEIGHT FOR GYPROCK STRATAWALL WITH C-STUDS AT 600mm CENTRES WALL
SYSTEM FRL /60/60
Wall Type
FRL/60/60

Wind
Loading
Pservice
kPa

0.25

0.35

0.50

Maximum Wall Height (m with Rondo C-Studs at 600mm centres


Wall Lining
(both sides)

Stud C64

Stud C76

Stud C92

0.50

0.75

1.15

0.55

0.75

0.55

0.75

13mm GYPROCK
plasterboards

2.72

3.13

3.53

3.20

3.30*

3.30*

3.30*

13mm FYRCHEK

2.72

3.13

3.53

3.20

3.58

3.60*

3.60*

6 or 9mm
CeminSeal
Wallboard

2.72

3.00*

3.00*

3.00*

3.00*

3.00*

3.00*

13mm GYPROCK
plasterboards

2.34

2.80

3.15

2.76

3.20

3.06

3.30*

13mm FYRCHEK

2.34

2.80

3.15

2.76

3.20

3.06

3.60*

6 or 9mm
CeminSeal
Wallboard

2.34

2.80

3.00*

2.76

3.00*

3.00*

3.00*

13mm GYPROCK
plasterboards

1.95

2.47

2.80

2.32

2.73

2.56

2.96

13mm FYRCHEK

1.95

2.47

2.80

2.32

2.73

2.56

2.96

6 or 9mm
CeminSeal
Wallboard

1.95

2.47

2.80

2.32

2.73

2.56

2.96

NOTE: * Height limits apply for FRL /90/90 and FRL 120/120. Refer to N GYP949 Gyprock StrataWall Installation Guide.

The Red Book

B3

TABLE B8:
MAXIMUM PERMITTED WALL HEIGHT/WIDTH FOR
LAMINATED SERVICES SYSTEMS (0.35 kPa)
Wall Height (maximum)
System N

2400

3000

3600

7200

Wall Width (maximum)


CSR967-S

Structural Design

1200

1200

1200

NA

1200

1200

1200

1200

2200

2100

2000

NA

CSR968-SA

3100

2700

2600

1200

CSR969-SA

4200

3200

3000

NA

CSREC 031-S
CSR968-S
CSR967-SA
CSREC 031-SA

Design
Considerations

-S = Screw Only Plasterboard Fixing


-SA = Screw and Adhesive Plasterboard Fixing
NA = Not Applicable

All walls must be designed for the applied loads. Guidance


is given for the selection of Rondo studs for non-loadbearing
internal walls only.
Loadbearing walls and walls subject to wind pressures shall
be appropriately designed to meet the relevant Australian
Standards or construction manuals.
Non-Loadbearing Walls
Maximum wall heights are shown in Tables B1 to B8. These
walls are designed for lateral loads only, using the composite
action of the frame and sheeting.
Non-loadbearing walls in this manual have been designed
as follows:

Introduction
CSR Gyprock and Cemintel steel frame wall systems
use zinc coated steel components with one or more layers
of Gyprock plasterboard and/or Cemintel fibre cement
linings fixed to one or both sides. A wide choice of systems
is available for both fire rated and non-fire rated applications
in non-loadbearing and loadbearing situations.
These wall systems are most often used in internal nonloadbearing applications, including commercial, industrial,
institutional, residential and high-rise residential construction.
Systems are also available for external walls.

Minimum design pressure of 0.25kPa and a maximum


deflection of (height 240) or 30mm maximum. (Based
on BCA Specification C1.8, 3.4 (b))
Fire rated walls have been designed to meet the
requirements of BCA Specification C1.8 Clause 3.4
Walls generally.
Internal wall studs are friction fitted into tracks with no
clearance at the bottom and a minimum allowance for
vertical expansion of 15mm at the top. Where vertical building
movement is expected an additional gap is required. In this
case deflection head tracks must be used.
Staggered stud walls using Rondo C studs must use the
CSR staggered stud clip to restrain the stud from twisting.
Insulation may need to be cut to fit between studs at 300mm
centres.
Wall tracks must be fixed to floors and ceilings at 600mm
maximum centres. Each plate fixing is required to withstand
a shear load of 0.75kN for a UDL of 0.25kPa and 1.1kN for
UDL of 0.35kPa.
Tall residential buildings often have exterior operable doors
and windows, resulting in internal walls being subject to
wind pressure. In these cases, walls must be designed for
the appropriate loads.

B4

The Red Book

Loadbearing Walls

Framing must be made from steel of up to 2.4mm BMT.

Walls designed as loadbearing and lined with GYPROCK


FYRCHEK meet the requirements of BCA Specification C1.8
Clause 3.4 Walls generally.

Wall plates must be fixed to the fire rated support structure


with steel fasteners such as expansion anchors, easy drive
masonry anchors and power driven fasteners.

The building designer must ensure loadbearing walls have


been designed:

Fyrchek and Cemintel fibre cement products must be


screw fixed only, adhesive is not permitted. Linings that
do not contribute to the system FRL may use adhesive.

To resist all applied loads.


To be in accordance with AS4600.
Assuming no contribution to axial strength is required of
the wall linings.
To meet the stated Fire Resistance Level (FRL), the axial load
capacity of some wall systems is reduced. This is a result of
the steel weakening at high temperature during a fire test.
The systems are noted with an Axial Capacity Reduction
percentage (ACR%). For these systems, the designer must
increase the applied loads before selecting stud size to
compensate for the axial capacity reduction percentage, as
shown in the system specification.
The capacity of head and base tracks for walls subject to
wind loads must be checked. Typically, studs are cleated
at head and base with a Rondo angle bracket. Contact
Rondo for more information on designing walls subject to
wind loads.

Fire Resistance
The steel frame wall systems in this manual are suitable
for the stated FRL when designed in accordance with the
structural considerations above. Wall system ratings apply
in either direction, unless noted otherwise.
CSR fire rated steel stud wall systems have been designed
with fire protection that limits the temperature of the
steel framing to a maximum of 450C at the FRL stated.
Therefore the structural design of the framing need only
provide for normal temperature conditions, and no additional
consideration of fire rating is required. In some systems this
temperature is exceeded and the axial capacity of the stud
must be reduced to compensate for the loss of strength. The
percentage reduction is noted for each affected systems.
To protect structural steel beams and columns that are
entirely within a wall, the FRL of the wall system must be at
least equivalent to that required by the structural member.
For example, a wall system with FRL 90/90/90 provides FRL
90// for a steel column within the wall.
Framing & Lining
Steel framed walls required to have an FRL must comply
with the following:

In wet areas, Gyprock Fyrchek MR must be used in lieu


of Gyprock Fyrchek.
For single layer systems and the first layer of multi-layer
systems, butt joints must be backed by either a stud or
nogging.
For multi-layer vertically sheeted applications, outer layer
butt joints may be reinforced using laminating screws
without the need for framing support.
Joints in the outer layer of all systems lined with
plasterboard or Wallboard must be set with Gyprock
paper tape. As a minimum, a single coat finish may be
used.
All joints in Texture Base Sheets must be formed on
framing.
Joints in external systems lined with Cemintel Texture
Base Sheet must be set with the tape and compound
recommended for the texture coating system.
For additional information on frame design and detailing,
including treatment at junctions, sub floor and roof areas,
cavity barriers and penetrations, refer to brochure NGYP544,
Gyprock Steel Frame Wall Systems.
The Fire Resistance Level (FRL) of the systems detailed in
this section will not be detrimentally affected by:
Increasing the thickness of the wall.
Increasing the cross-sectional dimensions of the framing
elements.
Decreasing the stud spacing.
Decreasing the fixing centres of wall sheet materials.
The inclusion of bulk cavity insulation materials such as
Glasswool, Rockwool and Polyester.
The use of Fyrchek MR, Impactchek, EC08 Fire or
EC08 Impact plasterboard in lieu of Fyrchek plasterboard
of the same thickness.
Additional layers of plasterboard or Cemintel fibre cement.
Wall curved in plan with a radius of curvature no less than
3m.
The attachment of light weight fixtures through to the framing.
The addition of an exterior cladding.

The Red Book

B5

Caulking
To attain the specified FRL, all perimeter gaps and
penetrations must be carefully and completely filled with
appropriate caulking material. CSR Gyprock Fire Mastic or
other tested fire and acoustic rated material of equivalent or
better performance must be used.
Vermiculite plaster has no capacity to accommodate building
movement and may not be suitable for use as a general purpose
fire rated caulking. Its use is specified in some wall/ceiling
junctions, refer to brochure NGYP570, Gyprock Ceiling
Systems Installation Guide.

Acoustic Performance
The acoustic performance of wall systems is expressed in
terms of Rw and Rw+Ctr where appropriate. The performance
of the as-built system may be affected by sound flanking, the
effectiveness of workmanship and caulking, the presence
and treatment of penetrations, and the inclusion of structural
elements and bridging items. Refer to Section A for detailed
information on addressing these issues.
General Notes.
The acoustic performance of systems may be adversely
affected by the use of studs with higher BMT or closer
spacings than those specified, or by the use of additional
linings fixed with battens.
In non-fire rated systems, to attain the stated acoustic
performance, use Gyprock Wet Area Acrylic Sealant,
Gyprock Fire Mastic or other tested acoustic rated material
of equivalent or better performance.
The acoustic performance of CSR wall systems is not
adversely affected by:
The order of lining sheets that are fixed direct to framing.
The substitution of Aquachek for Gyprock Plasterboard
CD of the same thickness.
The substitution of Gyprock Fyrchek MR for Fyrchek of
the same thickness.

Installation
Framing
CSR recommends steel components manufactured by
Rondo Building Services Pty Ltd. Additional information
on the steel components can be obtained from the Rondo
Building Services Pty Ltd, telephone 1300 367 663. Other
steel components of equivalent performance may be used,
however, it is the responsibility of the manufacturer of the
component to substantiate equivalent performance with the
recommended component.
For detailed information on wall junctions, intersections, frame
attachments and penetrations, refer to guide NGYP544,
Gyprock Steel Frame Wall Systems.
Shaftwall , SecurityWall , Party Wall, Cinema Wall,
Laminated systems and StrataWall systems have additional
installation details. Refer to the relevant installation guide.
Walls curved in plan may be built with steel stud frames.
Selection information on stud centres and plasterboard
thickness for various curvatures can be found in brochure
NGYP544, Gyprock Steel Frame Wall Systems.

Wallboard & Plasterboard Fixing


Walls may be built to achieve a particular Level of Finish
as defined in AS/NZS2589.1. The Level of Finish specified
can have requirements for frame alignment, jointing and
back blocking methods, and sheet orientation. CeminSeal
and Gyprock plasterboard may be installed vertically or
horizontally, although for some Levels of Finish horizontal
sheeting must be used.
Walls lined with Gyprock plasterboard or CeminSeal
Wallboard may be finished with tiles. For tiles greater than
32kg/m 2 or over 6.5mm thickness, specific installation
details apply. Refer to the appropriate installation manual.

Plasterboard Jointing & Finishing


Refer to the Gyprock Residential Installation Guide,
NGYP547 and Cemintel Wet Area Lining Systems,
NFC101 for detailed jointing and finishing information.
It should be noted that:
Multi-layered systems only require jointing and finishing of
the outer layer.
It is recommended that a water resistant taping
compound, such as Gyprock Wet Area Base Coat be
used at horizontal and vertical joints within wet areas such
as showers.

B6

The Red Book

Control Joints
Control joints must be installed to allow for structural
movement. Allowance for movement must be made through
the frame, lining and any tiles.

Components
Lining & Fixing Materials

Control joints must be installed at all construction joints in


the building and at the following locations:

Refer to Section A for detailed information on CSR lining


products, fixings, adhesive and accessories.

Non-tiled internal walls with fibre cement outer layer at


7.2m maximum centres.

For details on Cemintel Texture Base Sheet, refer to


brochure NFC122, Cemintel Texture Base Sheet & Texture
Coating System.

Tiled internal walls with fibre cement outer layer at 4.2m


maximum centres.
Walls with plasterboard outer layer at 12m maximum
centres.
External walls refer to the appropriate installation
manual.
At junctions with other building elements.
At changes of lining material.
At changes of structural support systems.
At each storey or rise of studs.

Framing
CSR recommends steel components manufactured by
Rondo Building Services Pty Ltd. Additional information
on the steel components can be obtained from the Rondo
Building Services Pty Ltd.
Other steel components of equivalent performance may be
used, however, it is the responsibility of the manufacturer of
the component to substantiate equivalent performance with
the recommended component.

External Walls
CSR external wall systems rely on a range of cladding
systems to provide weather resistance. There is a range of
effectiveness of these systems, and CSR recommends the
cladding be installed with a drained cavity. Cavity systems
allow drainage and drying of any water that penetrates, and
are known to have good long-term performance.
Sarking is also recommended to provide additional weather
protection to framing and lining.
External walls require specific design for condensation
control and energy efficiency, depending on the climate and
internal environment. Contact CSR Bradford for information
on thermal insulation systems and products.

TABLE B9: RONDO STEEL STUD AVAILABILITY


Stud Depth (mm)

Stud
BMT (mm)

51

64

76

92

150

0.50*

0.55*

0.75

1.15

NOTE: * Rondo Hemmed Stud

TABLE B10: QUIET STUD


Stud Depth 92mm

Stud
BMT (mm)
0.55

Length (mm)
2700

3000

3600

Stud BMT

Stud Depth

Length

TABLE B11: RONDO C-H STUD


Component

The Red Book

(mm)

(mm)

(mm)

64CH55

0.55

64

3000 / 3600

64CH90

0.90

64

4500

102CH90

0.55

102

3600 / 4300

102CH90

0.90

102

5500

B7

RONDO LIPPED STUD PROFILES

RONDO 501 CONTINUOUS


NOGGING BRACKET

35.0

35.5

Supplied in 2400mm lengths for


on-site cutting to length
8.15

8.0

30

37

Depth

Depth

30
BMT
0.75

BMT
1.15

18

8.0

6.35
35.0

33.5

RONDO STUD CLIP 126

RONDO QUIET STUD


45mm

6mm

GYPROCK STAGGERED STUD CLIP

92mm

Rondo
64mm
Lipped
Steel
Stud

Rondo
92mm
Track
6mm
43mm

CSR Gyprock
Staggered Stud Clip

RONDO HEMMED STUD


32.8

5.0

Depth

BMT
0.50/0.55

5.0
35.4

RONDO C-H STUD


35mm

64 or 102mm

25mm
35mm

B8

The Red Book

Steel Frame Internal Wall Systems Single Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 010a shown)

PKA-052

Lining material as per system table.


Steel Studs at 600mm maximum centres.
Lining material as per system table.
NOTES:
Acoustic performance valid for studs 0.50 BMT.

FRL
Report/Opinion

SYSTEM
N

STUD DEPTH mm
WALL LININGS

BOTH SIDES
1 x 10mm GYPROCK
Plasterboard CD.

BOTH SIDES
1 x 13mm GYPROCK
Plasterboard CD.

//

SIDE ONE
1 x 13mm GYPROCK
AQUACHEK Plasterboard.

//

CSR 015

36/26 37/27 38/29 40/31 42/33

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

//

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

WALL THICKNESS mm

42/33 42/33 43/34 45/36

39/31 39/32 40/33 41/34 43/36

77

41/31 42/32 43/33 45/35


90

102

118

176

44/35 44/35 45/36 47/38

39/31 40/33 41/34 42/35 44/37

77

42/32 43/33 44/34 46/36


90

102

118

176

(a) Nil

38/30 39/32 40/33 42/35 45/38

(b) 50 GW Partition 11kg

43/33 44/35 45/36 47/38 49/40

(c) 75 GW Partition 14kg

WALL THICKNESS mm

46/37 46/37 48/39 50/41

43/35 43/36 44/37 46/39 48/41

90

45/35 46/36 48/38 50/40


103

115

131

189

(a) Nil

35/28 37/30 38/31 40/33 43/37

(b) 50 GW Partition 11kg

40/31 42/33 43/34 45/36 47/39

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

44/35 44/35 46/37 48/40

40/33 41/34 42/35 44/37 46/40

71

43/33 44/34 46/36 48/39


84

96

112

170

(a) Nil

37/30 38/31 40/33 41/34 44/38

(b) 50 GW Partition 11kg

42/33 43/34 45/36 46/37 48/40

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6
WALL THICKNESS mm

The Red Book

170

39/29 41/32 42/33 43/34 45/36

(c) 75 GW Partition 14kg

(e) 60 Soundscreen 1.6

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

112

(b) 50 GW Partition 11kg

WALL THICKNESS mm

//

96

35/27 37/30 37/30 38/31 41/34

2 x 13mm GYPROCK
Plasterboard CD.

BOTH SIDES

84

(a) Nil

(d) TSB3/ASB3 Polyester

CSR 032

71

38/27 39/29 41/31 43/33

39/29 40/31 41/32 42/33 44/35

SIDE TWO

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

34/26 35/28 36/29 37/30 40/33

(e) 60 Soundscreen 1.6

BOTH SIDES

39/29 39/30 41/32 43/34

(b) 50 GW Partition 11kg

(d) TSB3/ASB3 Polyester

CSR 025

36/28 36/28 37/30 39/32 41/34

(a) Nil

1 x 13mm GYPROCK
Plasterboard CD.

1 x 13mm GYPROCK
Plasterboard CD.

150

31/23 32/24 33/26 35/28 38/31

SIDE TWO

SIDE ONE

92

(b) 50 GW Partition 11kg

WALL THICKNESS mm

CSR 011

76

(a) Nil

WALL THICKNESS mm

CSR 010

64

Rw / Rw+Ctr

(Refer to Section A)

CSR 005

//

51

CAVITY INFILL

45/36 46/37 47/38 49/41

42/35 42/35 44/37 45/38 47/41

77

44/34 46/36 47/37 49/40


90

102

118

176

B9

Steel Frame Internal Wall Systems Single Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 600a shown)

PKA-052

Lining material as per system table.


Steel Studs at 600mm maximum centres.
Lining material as per system table.
NOTES:
Acoustic performance valid for studs 0.50 BMT.

FRL
Report/Opinion

SYSTEM
N

STUD DEPTH mm
WALL LININGS

BOTH SIDES
2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 039

43/36 44/37 46/40 47/41 49/43

(b) 50 GW Partition 11kg

48/39 49/40 51/43 52/44 53/45

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

91

50/40 52/43 53/44 54/45


104

116

132

190

46/37 48/39 49/40 50/41 52/44

SIDE TWO

(d) TSB3/ASB3 Polyester

2 x 13mm GYPROCK
SOUNDCHEK
Plasterboard.

(e) 60 Soundscreen 1.6

SIDE ONE

(c) 75 GW Partition 11kg

WALL THICKNESS mm

WALL THICKNESS mm

90

49/39 50/40 51/41 53/44


103

115

131

189

44/35 43/34 44/35 46/37

39/31 41/34 41/34 42/35 44/37

77

43/33 43/33 44/34 46/36


90

102

118

176

(a) Nil

34/27 36/29 37/30 38/31 41/34

(b) 50 GW Partition 11kg

39/30 41/32 42/33 43/34 45/36

(c) 75 GW Partition 14kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

44/35 44/35 45/36 47/38

39/32 40/33 41/34 42/35 44/37

63

42/32 43/33 44/34 46/36


76

88

104

162

(a) Nil

39/32 40/33 41/34 42/35 45/39

(b) 50 GW Partition 11kg

44/35 45/36 46/37 47/38 49/41

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6
WALL THICKNESS mm

1 x 6mm CeminSeal
Wallboard.

39/29 42/33 42/33 43/34 45/36

(c) 75 GW Partition 11kg


(e) 60 Soundscreen 1.6

SIDE ONE

46/39 47/40 48/41 49/42 51/45

(b) 50 GW Partition 11kg


(d) TSB3/ASB3 Polyester

1 x 9mm CeminSeal
Wallboard.

50/41 50/41 51/42 53/45

34/26 37/30 37/30 38/31 41/34

1 x 13mm GYPROCK
Plasterboard CD.

BOTH SIDES

(a) Nil

SIDE TWO

CSR 601

B10

(b) 50 GW Partition 11kg

WALL THICKNESS mm

//

51/42 52/44 53/45 54/46

41/34 43/36 44/37 45/38 48/42

1 x 6mm CeminSeal
Wallboard.

CSR 605

48/41 48/41 50/44 51/45 52/46

(a) Nil

BOTH SIDES

//

150

1 x 13mm GYPROCK
SOUNDCHEK
Plasterboard.

CSR 600

//

92

SIDE ONE

1 x 13mm GYPROCK
IMPACTCHEK.

//

76

(a) Nil

WALL THICKNESS mm

CSR 033

64

Rw / Rw+Ctr

(Refer to Section A)

CSR 035

//

51

CAVITY INFILL

47/38 47/38 48/39 50/42

44/37 44/37 45/38 46/39 48/42

69

46/36 47/37 48/38 50/41


82

94

110

168

(a) Nil

34/26 35/28 37/30 37/30 41/34

(b) 50 GW Partition 11kg

39/29 40/31 42/33 42/33 45/36

(c) 75 GW Partition 14kg

SIDE TWO

(d) TSB3/ASB3 Polyester

1 x 13mm GYPROCK
Plasterboard CD.

(e) 60 Soundscreen 1.6


WALL THICKNESS mm

43/34 44/35 44/35 47/38

39/31 39/32 41/34 41/34 44/37

70

41/31 43/33 43/33 46/36


83

95

111

169

The Red Book

Steel Frame Internal Wall Systems Single Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 615a shown)

PKA-052

Lining material as per system table.


Steel Studs at 600mm maximum centres.
Lining material as per system table.
NOTES:
Acoustic performance valid for studs of 0.50 BMT.
*ACR = Axial Capacity Reduction

FRL
Report/Opinion

SYSTEM
N

CSR 606

STUD DEPTH mm
WALL LININGS

SIDE ONE

/60/60
30/30/30
60/60/60*

41/31 43/34 44/35 45/36 48/39

(c) 75 GW Partition 11kg


(e) 60 Soundscreen 1.6

FAR2357

WALL THICKNESS mm

/90/90
60/60/60
FAR2357

114

172

36/29 38/31 38/31 40/33 43/37


42/33 44/35 44/35 46/37 48/40

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

45/36 44/35 46/37 48/40

41/34 42/35 42/35 44/37 46/40

77

44/34 44/34 46/36 48/39


90

102

118

176

45/36 47/38 47/38 48/39 50/42

SIDE TWO

(c) 75 GW Partition 11kg

1 x 16mm GYPROCK
FYRCHEK plasterboard
(against studs).

(d) TSB3/ASB3 Polyester


(e) 60 Soundscreen 1.6
WALL THICKNESS mm

SIDE ONE

45/38 46/39 46/39 47/40 49/43

89

48/38 48/38 49/39 51/42


102

114

130

188

(b) 50 GW Partition 11kg

41/32 42/33 44/35 45/36 47/39

(c) 75 GW Partition 14kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

45/36 46/37 47/38 49/41

41/34 41/34 43/36 44/37 46/40

83

43/33 45/35 46/36 48/39


96

108

124

182

(a) Nil

40/33 42/35 43/36 44/37 47/41

(b) 50 GW Partition 11kg

45/36 47/38 48/39 49/40 51/43

SIDE TWO

(d) TSB3/ASB3 Polyester

FAR2357

2 x 13mm GYPROCK
FYRCHEK Plasterboard.

(e) 60 Soundscreen 1.6

1 x 16mm GYPROCK
FYRCHEK Plasterboard.

49/40 48/39 49/40 51/43

36/29 37/30 39/32 40/33 43/37

1 x 13mm GYPROCK
FYRCHEK Plasterboard.

SIDE ONE

(a) Nil

/90/90
and
30/30/30

The Red Book

98

(b) 50 GW Partition 14kg

WALL THICKNESS mm

*ACR 5%
From Fyrchek
lined side ONLY

86

(b) 50 GW Partition 11kg

1 x 16mm GYPROCK
FYRCHEK plasterboard.

CSR 038

73

44/34 45/35 46/36 49/39

1 x 16mm GYPROCK
FYRCHEK Plasterboard.

FAR2357

/60/60
30/30/30
60/60/60*

40/33 42/35 42/35 43/36 46/40

BOTH SIDES

CSR 040

41/33 42/35 43/36 44/37 47/40

(a) Nil

CSR 055

*ACR15%

45/36 45/36 46/37 49/40

SIDE ONE

1 x 6mm CeminSeal
Wallboard.

/90/90
60/60/60
90/90/90*

(a) Nil

WALL THICKNESS mm

CSR 615

150

(b) 50 GW Partition 11kg


(d) TSB3/ASB3 Polyester

1 x 13mm GYPROCK
FYRCHEK plasterboard.

*ACR15%

92

36/28 38/31 39/32 40/33 44/37

1 x 13mm GYPROCK
Plasterboard CD.

BOTH SIDES

76

(a) Nil

SIDE TWO

CSR 050

64

Rw / Rw+Ctr

(Refer to Section A)

1 x 9mm CeminSeal
Wallboard.

//

51

CAVITY INFILL

(c) 75 GW Partition 14kg

WALL THICKNESS mm

50/41 50/41 51/42 53/45

45/38 46/39 47/40 48/41 50/44

90

48/38 49/39 50/40 52/43


103

115

131

189

(a) Nil

35/27 37/30 37/30 39/32 42/35

(b) 50 GW Partition 11kg

40/30 42/33 42/33 44/35 46/37

(c) 75 GW Partition 11kg

SIDE TWO

(d) TSB3/ASB3 Polyester

1 x 13mm GYPROCK
Plasterboard CD.

(e) 60 Soundscreen 1.6


WALL THICKNESS mm

44/35 43/34 45/36 47/38

40/32 41/34 41/34 43/36 45/38

80

43/33 43/33 45/35 47/37


93

105

121

179

B11

Steel Frame Internal Wall Systems Single Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 075a shown)

PKA-052

Lining material as per system table.


Steel Studs at 600mm maximum centres.
Lining material as per system table.
NOTES:
Acoustic performance valid for studs of 0.50 BMT.
*ACR = Axial Capacity Reduction

FRL
Report/Opinion

SYSTEM
N

STUD DEPTH mm
WALL LININGS

*ACR15%
FAR2357

CAVITY INFILL

CSR 614

43/36 44/37 46/40 46/40 49/43


48/39 49/40 51/43 51/43 53/45

1 x 6mm CeminSeal
Wallboard.

(c) 75 GW Partition 11kg

1 x 13mm GYPROCK
FYRCHEK plasterboard.

(e) 60 Soundscreen 1.6

BOTH SIDES

FAR2357

1 x 6mm CeminSeal
Wallboard.

CSR 611
BOTH SIDES
CeminSeal

1 x 6mm
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR2357

(d) TSB3/ASB3 Polyester

CSR 075

*ACR10%

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6
WALL THICKNESS mm

130

188

52/43 52/44 53/45 54/46

49/42 49/42 50/44 51/45 52/46

95

51/41 52/43 53/44 54/45


108

120

136

194

44/37 45/38 46/40 47/41 49/43


49/40 50/41 51/43 52/44 53/45

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

52/43 52/44 53/45 54/46

49/42 49/42 50/44 51/45 52/46

95

51/41 52/43 53/44 54/45


108

120

136

194

(a) Nil

44/37 45/38 46/40 47/41 49/43

(b) 50 GW Partition 11kg

49/40 50/41 51/43 52/44 53/45

(d) TSB3/ASB3 Polyester


(e) 60 Soundscreen 1.6

52/43 52/44 53/45 54/46

49/42 49/42 50/44 51/45 52/46

103

51/41 52/43 53/44 54/45


116

128

144

202

(a) Nil

45/38 47/41 48/42 49/43 51/45

BOTH SIDES (ANY ORDER)

(b) 50 GW Partition 11kg

50/41 52/44 53/45 54/46 55/47

1 x 9mm CeminSeal
Wallboard.

(c) 75 GW Partition 11kg

1 x 16mm GYPROCK
FYRCHEK plasterboard.

(d) TSB3/ASB3 Polyester


(e) 60 Soundscreen 1.6

54/46 54/46 55/47 56/48

50/43 51/45 52/46 53/47 54/48

101

53/44 54/45 55/46 56/47


114

126

142

200

(a) Nil

43/36 45/39 46/40 47/41 49/43

(b) 50 GW Partition 11kg

48/39 50/42 51/43 52/44 53/45

BOTH SIDES

(c) 75 GW Partition 11kg

2 x 16mm GYPROCK
FYRCHEK plasterboard.

(d) TSB3/ASB3 Polyester


(e) 60 Soundscreen 1.6
WALL THICKNESS mm

B12

114

(b) 50 GW Partition 11kg

2 x 13mm GYPROCK
FYRCHEK plasterboard.

CSR 080

FAR2357

102

(a) Nil

WALL THICKNESS mm

/180/180
and
120/120/120

89

50/40 52/43 52/43 54/45

49/40 50/41 51/43 52/44 53/45

(c) 75 GW Partition 11kg

CSR 613

FAR2357

44/37 45/38 46/40 47/41 49/43

WALL THICKNESS mm

/120/120
90/90/90

51/42 52/44 52/44 54/46

(b) 50 GW Partition 11kg

BOTH SIDES

FAR2357

48/41 48/41 50/44 50/44 52/46

(a) Nil

WALL THICKNESS mm

/120/120
90/90/90
120/120/120*

150

(b) 50 GW Partition 11kg

*ACR15%

*ACR15%

92

(a) Nil

1 x 16mm GYPROCK
FYRCHEK plasterboard
(against studs).

/120/120
60/60/60
90/90/90*

76

BOTH SIDES (ANY ORDER)

WALL THICKNESS mm

/90/90
60/60/60
90/90/90*

64

Rw / Rw+Ctr

(Refer to Section A)

CSR 610
/90/90
30/30/30
60/60/60*

51

52/44 52/44 53/45 54/46

48/41 49/43 50/44 51/45 52/46

115

51/42 52/43 53/44 54/45


128

140

156

214

The Red Book

Steel Frame Internal Wall Systems Rondo Quiet Stud


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 043a shown)

ACOUSTIC
OPINION
PKA-052

Lining material as per system table.


Rondo Quiet Studs at 600mm maximum centres.
Lining material as per system table.
NOTES:
*ACR = Axial Capacity Reduction

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CSR 043
BOTH SIDES
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

STUD DEPTH mm
CAVITY INFILL (Refer to Section A)
(a) Nil

42/35

(b) 50 GW Partition 11kg

50/41

(c) 75 GW Partition 11kg

51/42

(d) TSB3/ASB3 Polyester

49/42

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

CSR 048
BOTH SIDES
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

CSR 044
/60/60
30/30/30
60/60/60*

BOTH SIDES
1 x 13mm GYPROCK
FYRCHEK plasterboard.

*ACR15%
FAR2357

CSR 045
/90/90
and
30/30/30

SIDE ONE (ANY ORDER)


1 x 13mm GYPROCK
FYRCHEK Plasterboard.
1 x 13mm GYPROCK
Plasterboard CD.
SIDE TWO

FAR2357

49/43

(b) 50 GW Partition 11kg

57/49

(c) 75 GW Partition 11kg

58/50

(d) TSB3/ASB3 Polyester

56/50

(e) 60

Soundscreen

2.0 batts

58/49

WALL THICKNESS mm

144

(a) Nil

41/34

(b) 50 GW Partition 11kg

49/40

(c) 75 GW Partition 14kg

51/42

(d) TSB3/ASB3 Polyester

48/41

(e) 60

Soundscreen

2.0 batts

51/41

WALL THICKNESS mm

118

(a) Nil

48/42

(b) 50 GW Partition 11kg

56/48

(c) 75 GW Partition 14kg

58/50

(d) TSB4/ASB4 Polyester batts

56/50

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

/90/90
60/60/60
FAR2357

The Red Book

144
48/42

(b) 50 GW Partition 11kg

59/48

1 x 16mm GYPROCK
FYRCHEK Plasterboard.

(c) 75 GW Partition 14kg

58/50

(d) TSB4/ASB4 Polyester batts

56/50

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

CSR 049

57/48

(a) Nil

1 x 6mm CeminSeal
Wallboard.

FAR2357

118

BOTH SIDES (ANY ORDER)

CSR 046

*ACR15%

51/41

(a) Nil

2 x 13mm GYPROCK
FYRCHEK Plasterboard.

/90/90
60/60/60
90/90/90*

92
Rw / Rw+Ctr

57/48
136

(a) Nil

45/38

(b) 50 GW Partition 11kg

53/44

(c) 75 GW Partition 11kg

54/45

SIDE TWO

(d) TSB4/ASB4 Polyester batts

52/45

2 x 16mm GYPROCK
FYRCHEK Plasterboard.

(e) 60 Soundscreen 1.6

54/44

SIDE ONE
1 x 16mm GYPROCK
FYRCHEK Plasterboard.

WALL THICKNESS mm

140

B13

Steel Frame Internal Wall Systems Staggered Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 110a shown)

PKA-052
NOT
Deemed
Discontinuous
Construction

Lining material as per system table.


Staggered Steel Studs at 600mm maximum centres
each side. Studs restrained in track or angle at top and
bottom with minimum 22mm clearance between stud and
opposing lining.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CSR 110
BOTH SIDES
1 x 13mm GYPROCK
Plasterboard CD.

//

CAVITY WIDTH mm
CAVITY INFILL (Refer to Section A)

BOTH SIDES
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

BOTH SIDES
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

38/31

41/34

46/37

48/39

(c) 75 GW Partition 11kg

47/38

49/40

(d) TSB3/ASB3 Polyester

45/38

47/40

47/37

49/39

(e) 60

Soundscreen

1.6

118

176

(a) Nil

41/34

44/38

(b) 50 GW Partition 11kg

49/40

51/43

(c) 75 GW Partition 11kg

50/41

52/44

(d) TSB3/ASB3 Polyester

48/41

50/44

(e) 60 Soundscreen 1.6

50/40

52/43

112

170

(a) Nil

42/35

45/39

(b) 50 GW Partition 11kg

50/41

52/44

(c) 75 GW Partition 11kg

51/42

53/45

(d) TSB3/ASB3 Polyester

49/42

51/45

(e) 60 Soundscreen 1.6

51/41

53/44

118

176

WALL THICKNESS mm

CSR 135

//

SIDE ONE

(a) Nil

44/37

47/40

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(b) 50 GW Partition 11kg

52/43

54/45

(c) 75 GW Partition 11kg

53/44

55/46

(d) TSB3/ASB3 Polyester

51/44

53/46

1.6

53/43

55/45

WALL THICKNESS mm

118

176

(a) Nil

38/31

42/35

(b) 50 GW Partition 11kg

46/37

49/40

(c) 75 GW Partition 11kg

47/38

50/41

SIDE TWO

(d) TSB3/ASB3 Polyester

45/38

48/41

1 x 6mm CeminSeal
Wallboard.

(e) 60 Soundscreen 1.6

47/37

50/40

111

169

(a) Nil

39/32

42/35

(b) 50 GW Partition 11kg

47/38

49/40

(c) 75 GW Partition 11kg

48/39

50/41

(d) TSB3/ASB3 Polyester

46/39

48/41

1.6

48/38

50/40

WALL THICKNESS mm

118

176

SIDE TWO
1 x 6mm CeminSeal
Wallboard.

CSR 631

CSR 632

//

SIDE ONE
1 x 13mm GYPROCK
Plasterboard CD.

//

SIDE ONE
1 x 13mm GYPROCK
Plasterboard CD.
SIDE TWO
1 x 13mm GYPROCK
IMPACTCHEK.

B14

Rw / Rw+Ctr

(b) 50 GW Partition 11kg

WALL THICKNESS mm

CSR 131

150

(a) Nil

WALL THICKNESS mm

CSR 125

92

(e) 60

Soundscreen

WALL THICKNESS mm

(e) 60

Soundscreen

The Red Book

Steel Frame Internal Wall Systems Staggered Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 132a shown)

PKA-052
NOT
Deemed
Discontinuous
Construction

Lining material as per system table.


Staggered Steel Studs at 600mm maximum centres
each side. Studs restrained in track or angle at top and
bottom with minimum 22mm clearance between stud and
opposing lining.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CSR 132
BOTH SIDES
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

CAVITY WIDTH mm
CAVITY INFILL (Refer to Section A)

/60/60
30/30/30
60/60/60*

BOTH SIDES
1 x 13mm GYPROCK
FYRCHEK plasterboard.

*ACR15%
FAR2357

CSR 153

49/43

51/45

58/50

59/51

(c) 75 GW Partition 11kg

58/50

59/51

(d) TSB3/ASB3 Polyester

56/50

57/51

58/49

59/50

(e) 60

Soundscreen

1.6

144

202

(a) Nil

41/34

44/38

(b) 50 GW Partition 11kg

49/40

51/43

(c) 75 GW Partition 11kg

50/41

52/44

(d) TSB3/ASB3 Polyester

48/41

50/44

(e) 60 Soundscreen 1.6

50/40

52/43

118

176

(a) Nil

50/44

52/46

(b) 50 GW Partition 11kg

58/50

59/51

(c) 75 GW Partition 11kg

59/51

60/52

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

(d) TSB3/ASB3 Polyester

57/51

58/52

(e) 60 Soundscreen 1.6

59/50

60/51

150

208

SIDE ONE

(a) Nil

45/38

48/42

2 x 13mm GYPROCK
FYRCHEK plasterboard.

(b) 50 GW Partition 11kg

53/44

55/47

(c) 75 GW Partition 11kg

54/45

56/48

(d) TSB3/ASB3 Polyester

52/45

54/48

1.6

54/44

56/47

WALL THICKNESS mm

131

189

(a) Nil

41/34

44/38

(b) 50 GW Partition 11kg

49/40

51/43

(c) 75 GW Partition 11kg

50/41

52/44

(d) TSB3/ASB3 Polyester

48/41

50/44

(e) 60 Soundscreen 1.6

50/40

52/43

124

182

BOTH SIDES
1 x 16mm GYPROCK
FYRCHEK plasterboard.

*ACR15%
FAR2357

CSR 152
/90/90
30/30/30

SIDE TWO
1 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR2357

CSR 155
/90/90
60/60/60
90/90/90*

BOTH SIDES
1 x 16mm GYPROCK
FYRCHEK plasterboard.

*ACR15%
FAR2357

WALL THICKNESS mm

(e) 60

Soundscreen

WALL THICKNESS mm
(a) Nil

47/41

50/44

BOTH SIDES (ANY ORDER)

(b) 50 GW Partition 11kg

55/47

57/49

1 x 6mm CeminSeal
Wallboard.

(c) 75 GW Partition 11kg

56/48

58/50

(d) TSB3/ASB3 Polyester

54/48

56/50

1.6

56/47

58/49

WALL THICKNESS mm

130

188

CSR 630
/90/90
30/30/30
60/60/60*
*ACR15%
FAR2357

The Red Book

Rw / Rw+Ctr

(b) 50 GW Partition 14kg

WALL THICKNESS mm

/90/90
60/60/60
90/90/90*

150

(a) Nil

WALL THICKNESS mm

CSR 150

92

1 x 13mm GYPROCK
FYRCHEK plasterboard.

(e) 60

Soundscreen

B15

Steel Frame Internal Wall Systems Staggered Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 175a shown)

PKA-052

Lining material as per system table.

TEST
TL461

Staggered Steel Studs at 600mm maximum centres


each side. Studs restrained in track or angle at top and
bottom with minimum 22mm clearance between stud and
opposing lining.

NOT
Deemed
Discontinuous
Construction

Lining material as per system table.


NOTES:
*ACR = Axial Capacity Reduction

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CSR 175
/120/120
90/90/90
120/120/120*

BOTH SIDES
2 x 13mm GYPROCK
FYRCHEK plasterboard.

*ACR10%
FAR2357

CAVITY WIDTH mm
CAVITY INFILL (Refer to Section A)

/180/180
120/120/120
FAR2357

B16

BOTH SIDES
2 x 16mm GYPROCK
FYRCHEK plasterboard.

150
Rw / Rw+Ctr

(a) Nil

48/42

50/44

(b) 50 GW Partition 11kg

56/48

57/49

(c) 75 GW Partition 14kg

58/50

59/51

(d) TSB4/ASB4 Polyester

56/50

57/51

(e) 60 Soundscreen 1.6

58/50

58/49

144

202

(a) Nil

48/42

50/44

(b) 50 GW Partition 11kg

56/48

57/49

(c) 75 GW Partition 14kg

58/50

59/51

(d) TSB4/ASB4 Polyester

56/50

57/51

1.6

57/48

58/49

WALL THICKNESS mm

156

214

WALL THICKNESS mm

CSR 180

92

(e) 60

Soundscreen

The Red Book

Steel Frame Internal Wall Systems Double Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 207a shown)

Lining material as per system table.

PKA-052

2 Rows of Steel Studs at 600mm maximum centres with


20mm minimum gap.

Discontinuous
Construction

Lining material as per system table.


NOTES:
Unless otherwise specified cavity infill is required in one
stud row only.
*ACR = Axial Capacity Reduction

FRL
Report/Opinion

SYSTEM
N

CAVITY WIDTH mm
WALL LININGS

CAVITY INFILL

BOTH SIDES
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

CSR 250
BOTH SIDES
1 x 13mm GYPROCK
FYRCHEK plasterboard.

*ACR15%
FAR2357

*ACR15%

46/40

47/41

48/42

(b) 50 GW Partition 11kg

53/45

54/46

55/47

56/48

(c) 75 GW Partition 11kg

55/47

55/47

56/48

57/49

(d) TSB3/ASB3 Polyester

52/46

53/47

54/48

55/49

(e) 60 Soundscreen 1.6

54/45

55/46

56/47

57/48

174

226

276

326

(a) Nil

44/38

45/39

46/40

47/41

(b) 50 GW Partition 11kg

52/44

53/45

54/46

55/47

(c) 75 GW Partition 11kg

54/46

54/46

55/47

56/48

(d) TSB3/ASB3 Polyester

51/45

52/46

53/47

54/48

(e) 60 Soundscreen 1.6

53/44

54/45

55/46

56/47

174

226

276

326

(a) Nil

50/44

51/45

52/46

53/47

BOTH SIDES (ANY ORDER)

(b) 50 GW Partition 11kg

58/50

59/51

60/52

61/53

1 x 13mm GYPROCK
FYRCHEK plasterboard.

(c) 75 GW Partition 11kg

60/52

60/52

61/53

62/54

(d) TSB3/ASB3 Polyester

57/51

58/52

59/53

60/54

59/50

60/51

61/52

62/53

186

238

288

338

1 x 6mm CeminSeal
Wallboard.

FAR2357

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

CSR 204
/90/90
30/30/30
FAR2357

SIDE ONE

(a) Nil

50/44

51/45

52/46

53/47

2 x 13mm GYPROCK
FYRCHEK plasterboard.

(b) 50 GW Partition 11kg

58/50

59/51

60/52

61/53

(c) 75 GW Partition 11kg

60/52

60/52

61/53

62/54

(d) TSB3/ASB3 Polyester

57/51

58/52

59/53

60/54

(e) 60 Soundscreen 1.6

59/50

60/51

61/52

62/53

193

245

295

345

SIDE TWO (ANY ORDER)


1 x 13mm GYPROCK
FYRCHEK plasterboard.
1 x 6mm CeminSeal
Wallboard.

The Red Book

300

45/39

WALL THICKNESS mm

CSR 207
/90/90
30/30/30
60/60/60*

250

(a) Nil

WALL THICKNESS mm

/60/60
30/30/30
60/60/60*

200

Rw / Rw+Ctr

(Refer to Section A)

CSR 208

//

148

WALL THICKNESS mm

B17

Steel Frame Internal Wall Systems Double Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 218a shown)

Lining material as per system table.

PKA-052

2 Rows of Steel Studs at 600mm maximum centres with


20mm minimum gap.

Discontinuous
Construction

Lining material as per system table.


NOTES:
Unless otherwise specified cavity infill is required in one
stud row only.
CSR 217 and 218 require batts in each stud row.
*ACR = Axial Capacity Reduction
FRL
Report/Opinion

SYSTEM
N

CSR 217

CAVITY WIDTH mm
WALL LININGS

SIDE ONE

FAR2357

(a) Nil

48/42

49/43

50/44

51/45

(b) 2 x 50 GW Partition 11kg

60/52

60/52

61/53

62/54

61/53

62/54

63/55

63/55

(d) 2 x TSB3/ASB3 Polyester

59/53

60/54

60/54

61/55

1 x 13mm GYPROCK
FYRCHEK plasterboard.

(e) 2 x 60 Soundscreen 1.6

61/52

62/53

62/53

63/54

187

239

289

339

(a) Nil

44/38

45/39

46/40

47/41

(b) 2 x 50 GW Partition 11kg

56/48

56/48

57/49

58/50

(c) 2 x 75 GW Partition 11kg

57/49

58/50

59/51

59/51

(d) 2 x TSB3/ASB3 Polyester

55/49

56/50

57/51

57/51

57/48

58/49

58/49

59/50

180

232

282

332

49/43

51/45

52/46

52/46

1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR2357

WALL THICKNESS mm

(e) 2 x 60

Soundscreen

1.6

WALL THICKNESS mm
(a) Nil

CSR 206
/90/90
60/60/60
90/90/90*
*ACR15%
FAR2357

BOTH SIDES (ANY ORDER)

(b) 50 GW Partition 11kg

57/49

59/51

60/52

60/52

1 x 10mm GYPROCK
Plasterboard CD.

(c) 75 GW Partition 11kg

59/51

60/52

61/53

61/53

1 x 16mm GYPROCK
FYRCHEK plasterboard.

(d) TSB3/ASB3 Polyester

56/50

58/52

59/53

59/53

(e) 60 Soundscreen 1.6

58/49

60/51

61/52

61/52

200

252

302

352

(a) Nil

44/38

45/39

46/40

47/41

(b) 50 GW Partition 11kg

52/44

53/45

54/46

55/47

(c) 75 GW Partition 11kg

54/46

54/46

55/47

56/48

(d) TSB3/ASB3 Polyester

51/45

52/46

53/47

54/48

53/44

54/45

55/46

56/47

180

232

282

332

WALL THICKNESS mm

CSR 255
/90/90
60/60/60
90/90/90*
*ACR15%
FAR2357

BOTH SIDES
1 x 16mm GYPROCK
FYRCHEK plasterboard.

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

B18

300

(c) 2 x 75 GW Partition 11kg

BOTH SIDES

*ACR15%

250

SIDE TWO

CSR 218
/90/90
60/60/60
90/90/90*

200

Rw / Rw+Ctr

(Refer to Section A)

2 x 13mm GYPROCK
FYRCHEK plasterboard.

/90/90
30/30/30

148

CAVITY INFILL

The Red Book

Steel Frame Internal Wall Systems Double Stud


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 212a shown)

Lining material as per system table.

PKA-052

2 Rows of Steel Studs at 600mm maximum centres with


20mm minimum gap.

TEST
ATF 1740

Lining material as per system table.

Discontinuous
Construction

NOTES:
Unless otherwise specified cavity infill is required in one
stud row only.
CSR 216 requires batts in each stud row.
*ACR = Axial Capacity Reduction
FRL
Report/Opinion

SYSTEM
N

CAVITY WIDTH mm
WALL LININGS

BOTH SIDES
2 x 13mm GYPROCK
FYRCHEK plasterboard

*ACR10%
FAR2357

FAR2357

50/44

51/45

52/46

53/47

(b) 50 GW Partition 11kg

58/50

59/51

60/52

61/53

(c) 75 GW Partition 11kg

60/52

60/52

61/53

62/54

(d) TSB3/ASB3 Polyester

57/51

58/52

59/53

60/54

1.6

59/50

60/51

61/52

62/53

(e) 60

Soundscreen

200

252

302

352

50/44

52/46

53/47

53/47

BOTH SIDES

(b) 50 GW Partition 11kg

58/50

60/52

61/53

61/53

1 x 6mm CeminSeal
Wallboard (against studs).

(c) 75 GW Partition 11kg

60/52

61/53

62/54

62/54

1 x 16mm GYPROCK
FYRCHEK plasterboard.

(d) TSB3/ASB3 Polyester

57/51

59/53

60/54

60/54

(e) 60 Soundscreen 1.6

59/50

61/52

62/53

62/53

192

244

294

344

(a) Nil

50/44

51/45

52/46

53/47

(b) 50 GW Partition 11kg

58/50

59/51

60/52

61/53

(c) 75 GW Partition 11kg

60/52

60/52

61/53

62/54

(d) TSB3/ASB3 Polyester

57/51

58/52

59/53

60/54

(e) 60 Soundscreen 1.6

59/50

60/51

61/52

62/53

212

264

314

364

WALL THICKNESS mm

CSR 280
/180/180
120/120/120

BOTH SIDES
2 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR2357

WALL THICKNESS mm

FRL
Report/Opinion

SYSTEM
N

CSR 216
/60/60
30/30/30
60/60/60*

CAVITY WIDTH mm
WALL LININGS

CAVITY INFILL
(Refer to Section A)

SIDE ONE
1 x 13mm GYPROCK
FYRCHEK Plasterboard.

(*ACR15%)

SIDE TWO

FAR 2357

1 x 16mm GYPROCK
FYRCHEK Plasterboard.

The Red Book

300

(a) Nil

WALL THICKNESS mm

*ACR15%

250

(a) Nil

CSR 212
/120/120
60/60/60
90/90/90*

200

Rw / Rw+Ctr

(Refer to Section A)

CSR 275
/120/120
90/90/90
120/120/120*

148

CAVITY INFILL

2x64 studs + 44 gap = 172


Rw / Rw+Ctr

(a) 165 GW Partition 11kg


+

55/50

50 GW Partition 11kg
WALL THICKNESS mm

201

B19

Steel Frame Internal Wall Systems StrataWall Single Cavity


SYSTEM SPECIFICATION

ACOUSTIC
OPINION
or
TEST

TYPICAL LAYOUT (CSR 222a shown)

Test
ATF 1912

Lining material as per system table laminated to Shaft


Liner Panel.

Test
ATF 19322

2 x 25mm GYPROCK Shaft Liner Panel in H-Studs at


600mm maximum centres.
Minimum 12mm gap.

Opinion
RP 02267S

Steel studs at 600mm maximum centres.


Cavity insulation as per system table.

Discontinuous
Construction

Lining material as per system table, fixed to studs.

FRL
Report/Opinion

SYSTEM
N

CSR 222
/120/120
WFRA
21241

WALL LININGS

WFRA
21241

(a) Nil

52/44

53/45

(b) 75 GW Partition 11kg

56/48

(c) 100 GW Partition 14kg

59/51

56/48

153

177
54/46

WALL THICKNESS mm
(a) Nil

53/45

1 x 13mm GYPROCK
plasterboard CD.

(b) 75 GW Partition 11kg

58/50

(c) 100 GW Partition 14kg

59/51

58/50

153

177

(a) Nil

53/45

53/45

SHAFT LINER PANEL SIDE


1 x 13mm GYPROCK
plasterboard CD.

WFRA
21241

(d) TSB5 Polyester batts

SHAFT LINER PANEL SIDE

1 x 13mm GYPROCK
SOUNDCHEK.

/120/90

(d) TSB5 Polyester batts


WALL THICKNESS mm

(b) 75 GW Partition 11kg

58/50

STUD SIDE

(c) 100 GW Partition 14kg

58/50

1 x 6mm CeminSeal
Wallboard.

(d) TSB5 Polyester batts

58/50

146

170

WALL THICKNESS mm

CSR 226
/120/90
WFRA
21241

B20

Rw / Rw+Ctr

1 x 13mm GYPROCK
plasterboard CD.

STUD SIDE

CSR 225

100

SHAFT LINER PANEL SIDE

1 x 13mm GYPROCK
plasterboard CD.

/120/120

76

CAVITY INFILL (Refer to Section A)

STUD SIDE

CSR 223

GAP + STUD DEPTH mm

SHAFT LINER PANEL SIDE

(a) Nil

54/46

55/47

1 x 13mm GYPROCK
plasterboard CD.

(b) 75 GW Partition 11kg

59/51

STUD SIDE
1 x 9mm CeminSeal
Wallboard.

(c) 100 GW Partition 14kg


(d) TSB5 Polyester batts
WALL THICKNESS mm

60/52

59/51

149

173

The Red Book

Steel Frame Internal Wall Systems StrataWall Services Cavity


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 230 shown)

Lining material as per system table fixed to furring


channels.

ACOUSTIC
OPINION
or
TEST
Opinion
RP 02267S

Cavity insulation as per system table.

Discontinuous
Construction

Furring channel fixed to all H-studs with Rondo Beta Fix


Clips at 600mm max.vertical centres, in 50mm cavity.
2 x 25mm GYPROCK Shaft Liner Panel in H-Studs at
600mm maximum centres.
20mm gap.
Steel studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table, fixed to studs.

FRL
Report/Opinion

SYSTEM
N

CSR 230
/120/120
WFRA
21241

WFRA
21241

WFRA
21241

Rw / Rw+Ctr
60/50

60/50

1 x 13mm GYPROCK
plasterboard CD.

(b) 100 GW Partition 14kg 50 GW Partition 11kg

61/51

61/51

(c) TSB5 Polyester batts

60/50

60/50

211

239

TSB2 Polyester batts

MINIMUM WALL THICKNESS mm

STUD SIDE

(a) 75 GW Partition 11kg

50 GW Partition 11kg

62/53

62/53

1 x 13mm GYPROCK
SOUNDCHEK.

(b) 100 GW Partition 14kg 50 GW Partition 11kg

62/53

62/53

(c) TSB5 Polyester batts

61/52

62/53

211

239

50 GW Partition 11kg

60/50

60/50

(b) 100 GW Partition 14kg 50 GW Partition 11kg

61/51

61/51

(c) TSB5 Tontine Polyester TSB2 Tontine Polyester 60/50

60/50

1 x 13mm GYPROCK
SOUNDCHEK.

STUD SIDE
1 x 13mm GYPROCK
AQUACHEK.

TSB2 Polyester batts

MINIMUM WALL THICKNESS mm


(a) 75 GW Partition 11kg

FURRING CHANNEL SIDE


1 x 13mm GYPROCK
AQUACHEK.

MINIMUM WALL THICKNESS mm

The Red Book

92

50 GW Partition 11kg

FURRING CHANNEL SIDE

CSR 235

64

(a) 75 GW Partition 11kg

1 x 13mm GYPROCK
plasterboard CD.

/120/120

CAVITY INFILL (Refer to Section A)


STUD CAVITY
FURRING CAVITY

STUD SIDE

FURRING CHANNEL SIDE

CSR 231

/120/120

STUD DEPTH mm
WALL LININGS

211

239

B21

Steel Frame Internal Wall Systems StrataWall Double Cavity


SYSTEM SPECIFICATION

ACOUSTIC
OPINION
or
TEST

TYPICAL LAYOUT (CSR 240a shown)

Lining material as per system table fixed to studs - Side 1.

Opinion
RP 02267S

Steel studs at 600mm maximum centres.


Cavity insulation as per system table.

Discontinuous
Construction

20mm gap.
2 x 25mm GYPROCK Shaft Liner Panel in H-Studs at
600mm maximum centres.
20mm gap.
Cavity insulation as per system table.
Steel studs at 600mm maximum centres
Lining material as per system table fixed to studs - Side 2.

FRL
Report/Opinion

SYSTEM
N

CAVITY INFILL (Refer to Section A)

CSR 240
/120/120

SIDE 1 AND 2

64

76

Rw / Rw+Ctr

(a) Nil

58/47

58/47

(b) 75 GW Partition 11kg - both sides

62/53

62/53

63/54

62/53

62/53

245

269

(a) Nil

59/48

60/49

SIDE 1 AND 2

(b) 75 GW Partition 11kg - both sides

64/55

65/56

1 x 13mm GYPROCK
SOUNDCHEK.

(d) TSB5 Polyester - both sides

63/54

63/54

245

269

1 x 13mm GYPROCK
plasterboard CD.

WFRA
21241

STUD DEPTH mm

WALL LININGS

(c) 100 GW Partition 14kg - both sides


(d) TSB5 Polyester - both sides
MINIMUM WALL THICKNESS mm

CSR 241
/120/120
WFRA
21241

MINIMUM WALL THICKNESS mm

CSR 243
/120/120

SIDE 1 AND 2
1 x 13mm GYPROCK
AQUACHEK.

WFRA
21241

(a) Nil

58/47

58/47

(b) 75 GW Partition 11kg - both sides

62/53

63/54

(c) 100 GW Partition 14kg - both sides

63/54

62/53

63/54

245

269

(b) 75 GW Partition 11kg - both sides

62/53

62/53

(c) 100 GW Partition 14kg - both sides

63/54

237

261

(d) TSB5 Polyester - both sides


MINIMUM WALL THICKNESS mm

CSR 244
/60/60

SIDE 1 AND 2

SF 45743

1 x 9mm CeminSeal
Wallboard.

MINIMUM WALL THICKNESS mm

B22

The Red Book

Steel Frame Internal Wall Systems Party Wall 25mm Fire Barrier
SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 100 shown)

Lining material as per system table.

ACOUSTIC
OPINION
PKA-052

Steel studs at 600mm maximum centres.


Discontinuous
Construction

Cavity insulation as per system table.


20-40mm separation between frame and GYPROCK
SHAFT LINER PANEL.
25mm GYPROCK SHAFT LINER PANEL between steel HStuds at 600mm maximum centres.
20-40mm separation between frame and GYPROCK
SHAFT LINER PANEL.
Cavity insulation as per system table.
Steel studs at 600mm maximum centres.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

STUD DEPTH mm
WALL LININGS

CAVITY INFILL (Both Sides)


(Refer to Section A)

64

76

Rw / Rw+Ctr

CSR 100
(a) 75 GW Partition 14kg

60/48

61/49

60/60/60

BOTH SIDES

(b) 110 GW Partition 11kg

62/50

62/50

EWFA 45743

2 x 10mm GYPROCK
Plasterboard CD.

(c) 88 RW Soundscreen R2.5

61/49

62/50

257

289

MINIMUM WALL THICKNESS mm

CSR 101
(a) 75 GW Partition 14kg

62/50

62/51

60/60/60

BOTH SIDES

(b) 110 GW Partition 11kg

63/52

63/52

EWFA 45743

2 x 13mm GYPROCK
Plasterboard CD.

(c) 88 RW Soundscreen R2.5

63/51

63/52

269

301

MINIMUM WALL THICKNESS mm

CSR 102
(a) 75 GW Partition 14kg

60/48

61/49

60/60/60

BOTH SIDES

(b) 110 GW Partition 11kg

62/50

62/50

EWFA 45743

1 x 13mm GYPROCK
SOUNDCHEK.

(c) 88 RW Soundscreen R2.5

61/49

62/50

243

275

MINIMUM WALL THICKNESS mm

CSR 103
60/60/60
EWFA 45743

BOTH SIDES

(a) 75 GW Partition 11kg

61/49

61/50

1 x 6mm CeminSeal
Wallboard.

(b) 75 GW Partition 14kg

62/50

62/51

(c) 88 RW Soundscreen R2.5

63/51

63/52

249

281

1 x 10mm GYPROCK
AQUACHEK.

MINIMUM WALL THICKNESS mm

The Red Book

B23

Steel Frame Internal Wall Systems Party Wall 41mm Fire Barrier
SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 111a shown)

Lining material as per system table.

PKA-052

Steel studs at 600mm maximum centres.

Discontinuous
Construction

Cavity insulation as per system table.


20-40mm separation between frame and GYPROCK
SHAFT LINER PANEL.
25mm GYPROCK SHAFT LINER PANEL between steel Hstuds at 600mm maximum centres.
16mm GYPROCK FYRCHEK screw laminated to SHAFT
LINER
20-40mm separation between frame and GYPROCK
FYRCHEK.
Cavity insulation as per system table.
Steel studs at 600mm maximum centres.
Lining material as per system table.
FRL
Report/Opinion

SYSTEM
N

STUD DEPTH mm
WALL LININGS

64

CAVITY INFILL (Both Sides)

76

92

Rw / Rw+Ctr

(Refer to Section A)

CSR 111
(a) 50 GW Partition 11kg

61/48

61/48

62/50

90/90/90

BOTH SIDES

(b) 75 GW Partition 14kg

63/50

63/50

64/52

EWFA 45743

1 x 13mm GYPROCK
Plasterboard CD.

(c) 60 RW Soundscreen R1.6

62/48

62/48

63/50

235

259

291

(a) 50 GW Partition 11kg

61/48

61/48

62/50

(b) 75 GW Partition 14kg

63/50

63/50

64/52

(c) 88 RW Soundscreen R2.5

64/51

64/51

65/53

228

252

284

MINIMUM WALL THICKNESS mm

CSR 113

SIDE ONE
1 x 6mm CeminSeal
Wallboard.

90/90/90

SIDE TWO

EWFA 45743

1 x 13mm GYPROCK
Plasterboard CD.

MINIMUM WALL THICKNESS mm

CSR 114
(a) 50 GW Partition 11kg

61/48

61/49

62/50

90/90/90

BOTH SIDES

(b) 75 GW Partition 14kg

63/50

63/51

64/52

EWFA 45743

1 x 6mm CeminSeal
Wallboard.

(c) 60 RW Soundscreen R1.6

62/48

62/49

63/50

221

245

277

MINIMUM WALL THICKNESS mm

CSR 115
(a) 50 GW Partition 11kg

62/50

62/50

63/51

90/90/90

BOTH SIDES

(b) 75 GW Partition 11kg

63/51

63/51

64/52

EWFA 45743

1 x 13mm GYPROCK
AQUACHEK.

(c) 60 RW Soundscreen R1.6

63/50

63/50

64/51

235

259

291

MINIMUM WALL THICKNESS mm

B24

The Red Book

Steel Frame Internal Wall Systems SecurityWall


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 292a shown)

PKA-054
Discontinuous
Construction

Lining material as per system table.


Gyprock SecurityWall Panel 27.
Cavity determined by track width.
Gyprock SecurityWall Panel 27.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CSR 290
BOTH SIDES
1 x 13mm GYPROCK
Plasterboard CD.

//

TRACK WIDTH mm

51

CAVITY INFILL (Refer to Section A)


(a) Nil

46/37

47/39

(b) 50 GW Partition 11kg

53/44

54/46

(c) 75 GW Partition 11kg

54/45

55/47

(d) TSB4/ASB4 Polyester

53/44

54/46

131

144

(a) Nil

47/39

48/40

(b) 50 GW Partition 11kg

54/46

55/47

(c) 75 GW Partition 11kg

55/47

56/48

(d) TSB4/ASB4 Polyester

54/46

55/47

131

144

WALL THICKNESS mm

CSR 291
BOTH SIDES

/60/60

1 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR2039

WALL THICKNESS mm

CSR 292
BOTH SIDES
1 x 16mm GYPROCK
FYRCHEK plasterboard.

/90/90
FAR2039

1 x 10mm GYPROCK
plasterboard CD.

(a) Nil

51/43

53/45

(b) 50 GW Partition 11kg

58/50

60/52

(c) 75 GW Partition 11kg

59/51

61/53

(d) TSB4/ASB4 Polyester

58/50

60/52

157

170

WALL THICKNESS mm
SYSTEM SPECIFICATION

64
Rw / Rw+Ctr

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 293a shown)

PKA-054
Discontinuous
Construction

Lining material as per system table.


Gyprock SecurityWall Panel 27.
Cavity width as per system table.
Steel Studs at 600mm maximum centres with minimum
20mm gap to Security Wall Panel.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CAVITY WIDTH mm
CAVITY INFILL (Refer to Section A)

84

96
Rw / Rw+Ctr

CSR 293
/90/90
FAR2039

The Red Book

BOTH SIDES

(a) Nil

50/42

51/43

1 x 16mm GYPROCK
FYRCHEK plasterboard.

(b) 50 GW Partition 11kg

57/49

58/50

(c) TSB4/ASB4 Polyester

57/49

58/50

163

175

1 x 10mm GYPROCK
plasterboard CD.

WALL THICKNESS mm

B25

Steel Frame Internal Wall Systems SecurityWall


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 295a shown)

PKA-054

Lining material as per system table.


Gyprock SecurityWall Panel 50.

Discontinuous
Construction

Cavity determined by track width.


Gyprock SecurityWall Panel 50.
Lining material as per system table.
NOTES:
^ SecurityWall Panel ribs offset to enable insulation to fit.

FRL
Report/Opinion

SYSTEM
N

TRACK WIDTH mm
WALL LININGS

/60/60

BOTH SIDES

FCO 2039

1 x 13mm GYPROCK
FYRCHEK plasterboard.

BOTH SIDES

/90/90

1 x 16mm GYPROCK
FYRCHEK plasterboard.

FCO 2039

1 x 10mm GYPROCK
plasterboard CD.

48/40

50/42

51/43

(b) 50 GW Partition 11kg

55/47^

57/49

58/50

(c) 75 GW Partition 11kg

58/50^

59/51

(d) TSB2/ASB2 Polyester

53/45^

55/47

56/48

154

177

190

(a) Nil

52/45

54/47

55/48

(b) 50 GW Partition 11kg

59/52^

61/54

62/55

(c) 75 GW Partition 11kg

62/55^

63/56

(d) TSB2/ASB2 Polyester

57/50^

59/52

60/53

180

203

216

(a) Nil

49/41

51/43

52/44

(b) 50 GW Partition 11kg

56/48^

58/50

59/51

(c) 75 GW Partition 11kg

59/51^

60/52

(d) TSB2/ASB2 Polyester

54/46^

56/48

57/49

160

183

196

WALL THICKNESS mm

CSR 297
/90/90

BOTH SIDES

FCO 2039

1 x 16mm GYPROCK
FYRCHEK plasterboard.

64

(a) Nil

WALL THICKNESS mm

CSR 295

51
Rw / Rw+Ctr

(Refer to Section A)

CSR 294

WALL THICKNESS mm

B26

28

CAVITY INFILL

The Red Book

Steel Frame Internal Wall Systems SecurityWall


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 296a shown)

PKA-054

Lining material as per system table.

Discontinuous
Construction

Gyprock SecurityWall Panel 50.


Cavity width as per system table.
Steel Studs at 600mm maximum centres with minimum
20mm gap to Security Wall Panel.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CAVITY WIDTH mm

84

96

CAVITY INFILL (Refer to Section A)

112

Rw / Rw+Ctr

CSR 296
/90/90
FCO 2039

BOTH SIDES

(a) Nil

52/44

53/46

54/47

1 x 16mm GYPROCK
FYRCHEK plasterboard.

(b) 75 GW Partition 11kg

60/52

61/54

62/55

(c) TSB4/ASB4 Polyester

59/51

60/53

61/54

186

198

214

1 x 10mm GYPROCK
plasterboard CD.
WALL THICKNESS mm

CSR 298
(a) Nil

48/40

49/41

50/42

/90/90

BOTH SIDES

(b) 75 GW Partition 11kg

56/48

57/49

58/50

FCO 2039

1 x 16mm GYPROCK
FYRCHEK plasterboard.

(c) TSB4/ASB4 Polyester

55/47

56/48

57/49

166

178

194

WALL THICKNESS mm

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 285 shown)

Lining material as per system table.


Gyprock SecurityWall Panel 27 or
SecurityWall Panel 50.
Cavity determined by track width.
Gyprock SecurityWall Panel 27 or
SecurityWall Panel 50.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

TRACK/PANEL

27

CAVITY INFILL (Refer to Section A)

50
Rw / Rw+Ctr

CSR 284
BOTH SIDES

FRL
//

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(a) Nil

WALL THICKNESS mm

49

71

55

77

CSR 285

FRL
//

BOTH SIDES

(a) Nil

1 x 13mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm

The Red Book

B27

Steel Frame Internal Wall Systems Resilient Mount


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 061a shown)

Lining material as per system table.


PKA-052

Steel Studs at 600mm maximum centres.


Continuous nogging aligned with every Gyprock Resilient
Mount.

NOT
Deemed
Discontinuous
Construction

Gyprock Resilient Mounts screw fixed to one side of


stud
RONDO N308 or N129 Furring Channel clipped to
resilient mounts.
Lining material as per system table.
NOTES:
*ACR = Axial Capacity Reduction.
FRL
Report/Opinion

SYSTEM
N

CSR 060

STUD DEPTH mm
WALL LININGS

SIDE ONE (MOUNT SIDE)


2 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR2357

1 x 13mm GYPROCK
FYRCHEK plasterboard.

SIDE TWO

CSR 061
BOTH SIDES
2 x 13mm GYPROCK
FYRCHEK plasterboard.

*ACR10%

CAVITY INFILL

FAR2357

/180/180
and
120/120/120
FAR2357

BOTH SIDES
2 x 16mm GYPROCK
FYRCHEK plasterboard.

150

45/38

45/38

47/40

48/42

(b) 50 GW Partition 11kg

53/44

52/43

54/45

55/47

(c) 75 GW Partition 11kg

54/45

54/45

56/47

56/48

(d) TSB3/ASB3 Polyester

52/45

52/45

53/46

54/48

54/44

54/45

55/45

56/47

131

143

159

217

(a) Nil

48/42

49/43

49/43

51/45

(b) 50 GW Partition 11kg

56/48

56/48

56/48

58/50

(c) 75 GW Partition 11kg

57/49

58/50

58/50

59/51

(d) TSB3/ASB3 Polyester

55/49

56/50

55/49

57/51

57/48

58/49

57/48

59/50

144

156

172

230

(a) Nil

48/42

48/42

49/43

50/44

(b) 50 GW Partition 11kg

56/48

55/47

56/48

57/49

(c) 75 GW Partition 14kg

57/49

57/49

58/50

58/50

(d) TSB3/ASB3 Polyester

55/49

55/49

55/49

56/50

57/48

57/48

57/48

58/49

156

168

184

242

(e) 60

Soundscreen

1.6

MIN. WALL THICKNESS mm

(e) 60

Soundscreen

1.6

(e) 60

Soundscreen

1.6

MIN. WALL THICKNESS mm

B28

92

(a) Nil

MIN. WALL THICKNESS mm

CSR 062

76

Rw / Rw+Ctr

(Refer to Section A)

/90/90
and
30/30/30

/120/120
90/90/90
120/120/120*

64

The Red Book

Steel Frame Internal Wall Systems Cinema Wall


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 945 shown)

ACOUSTIC
OPINION
PKA-201001

Lining material as per system table.


Steel columns, to engineers design.

NOT
Deemed
Discontinuous
Construction

Girts fixed to columns with GYPROCK CINEMA WALL


MOUNTS.
Top hat sections at 900mm maximum centres to
engineers design.
2 x layers glasswool or polyester insulation. Refer to
insulation specification.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CAVITY INFILL (Refer to Section A)

Rw

CSR 945
120/120/120
FAR2357

(a) 2 x Tontine Acoustisorb-1

77

BOTH SIDES

(b) 2 x 110 Bradford Glasswool Building Blanket

77

3 x 16mm GYPROCK
FYRCHEK plasterboard

(c) 2 x Autex AAB32-100

77

MINIMUM WALL THICKNESS mm

CSR 946

SIDE ONE
3 x 16mm GYPROCK
FYRCHEK plasterboard

120/120/120

SIDE TWO

FAR2357

4 x 16mm GYPROCK
FYRCHEK plasterboard

471

(a) 2 x Tontine Acoustisorb-1

79

(b) 2 x 110 Bradford Glasswool Building Blanket

79

(c) 2 x Autex AAB32-100

79

MINIMUM WALL THICKNESS mm

487

CSR 947
120/120/120
FAR2357

(a) 2 x Tontine Acoustisorb-1

81

BOTH SIDES

(b) 2 x 110 Bradford Glasswool Building Blanket

81

4 x 16mm GYPROCK
FYRCHEK plasterboard

(c) 2 x Autex AAB32-100

81

MINIMUM WALL THICKNESS mm

The Red Book

503

B29

Steel Frame Internal Wall Systems Lined One Side


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 089a shown)

ACOUSTIC
OPINION
PKA-052

Steel Studs at 600mm maximum centres.


Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CAVITY INFILL
(Refer to Section A)

Rw / Rw+Ctr

CSR 085

//

1 x 13mm GYPROCK CD
plasterboard.

(a) Nil

24/22

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(a) Nil

25/22

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

(a) Nil

31/28

2 x 13mm GYPROCK
FYRCHEK plasterboard.

(a) Nil

33/30

2 x 16mm GYPROCK
FYRCHEK plasterboard.

(a) Nil

33/30

CSR 086

//

CSR 089

//

Fire rated from


lined side only

CSR 090

/30/30
and
30/30/30
FAR2357

Fire rated from


lined side only

/60/60
and
60/60/60

CSR 091

FAR2357

B30

The Red Book

Steel Frame Internal Wall Systems Lined One Side


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 092a shown)

ACOUSTIC
OPINION
PKA-052

Steel Studs at 600mm maximum centres.


Lining material as per system table.

FRL
Report/Opinion
Fire rated from
lined side only

SYSTEM
N

STUD DEPTH mm
WALL LININGS

CAVITY INFILL
(Refer to Section A)

ALL
Rw / Rw+Ctr

CSR 092

/90/90
and
90/90/90

3 x 13mm GYPROCK
FYRCHEK plasterboard.

(a) Nil

36/33

3 x 16mm GYPROCK
FYRCHEK plasterboard.

(a) Nil

36/33

FAR2357
Fire rated from
lined side only

/120/120
and
120/120/120

CSR 093

FAR2357

The Red Book

B31

Steel Frame Internal Wall Systems Shaft Wall


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 971 shown)

PKA-052

Lining material as per system table.


64 or 102mm C-H Metal Studs at 600mm maximum
centres.
Lining material as per system table.
NOTE:
Acoustic performance valid for studs of 0.5mm BMT

FRL
Report/Opinion

SYSTEM
N

CSR 970

BRANZ
LOP 493

CSR 971

Test SI 1517

B32

38/31

42/35

43/34

47/38

(c) 75 GW Partition 14kg

49/40

(d) TSB3/ASB3 Polyester

42/35

46/39

48/38

80

118

(a) Nil

41/34

46/40

(b) 50 GW Partition 11kg

46/37

51/43

(c) 75 GW Partition 14kg

53/45

SIDE ONE

(d) TSB3/ASB3 Polyester

45/38

50/44

2 x 13mm GYPROCK
FYRCHEK plasterboard.

(e) 60 Soundscreen 1.6

52/43

90

128

(a) Nil

41/34

46/40

(b) 50 GW Partition 11kg

46/37

51/43

(c) 75 GW Partition 14kg

53/45

SIDE ONE

(d) TSB3/ASB3 Polyester

45/38

50/44

2 x 16mm GYPROCK
FYRCHEK plasterboard.

(e) 60 Soundscreen 1.6

52/43

96

134

BETWEEN STUDS
1 x 25mm GYPROCK
SHAFT LINER PANEL.

FAR3637

Rw / Rw+Ctr

(b) 50 GW Partition 11kg

1 x 16mm GYPROCK
FYRCHEK plasterboard.

/90/90

CAVITY INFILL

102

(a) Nil

BETWEEN STUDS

SIDE ONE

CSR 977

64

(Refer to Section A)

1 x 25mm GYPROCK
SHAFT LINER PANEL.

/60/60

/120/120

STUD DEPTH mm
WALL LININGS

BETWEEN STUDS
1 x 25mm GYPROCK
SHAFT LINER PANEL.

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

WALL THICKNESS mm

WALL THICKNESS mm

The Red Book

Steel Frame Internal Wall Systems Laminated Services


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 967 shown)

PKA-052

Perimeter framing 25/50 x 50 x 0.7 BMT steel angle.


3 x GYPROCK FYRCHEK/SHAFT LINER PANEL
laminated with screws (S), or screws and full cover
adhesive (SA).

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CAVITY INFILL
(Refer to Section A)

Rw

CSR 967S
/90/90
WFRA 21898

3 x 13mm GYPROCK
FYRCHEK plasterboard
(screw fixing).

(a) Nil

35

3 x 13mm GYPROCK
FYRCHEK plasterboard
(screw & adhesive fixing).

(a) Nil

35

3 x 16mm GYPROCK
FYRCHEK plasterboard
(screw fixing).

(a) Nil

36

3 x 16mm GYPROCK
FYRCHEK plasterboard
(screw & adhesive fixing).

(a) Nil

36

(a) Nil

37

CSR 967SA
/90/90
WFRA 21898

CSR 968S
/120/120
WFRA 21898

CSR 968SA
/120/120
WFRA 21898

CSR 969SA

1 x 16mm GYPROCK
FYRCHEK plasterboard.

/120/120

1 x 25mm GYPROCK
SHAFT LINER PANEL.

WFRA 21898

1 x 16mm GYPROCK
FYRCHEK plasterboard
(screw & adhesive fixing).

The Red Book

B33

Steel Frame Internal Wall Systems Laminated Services


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 136a shown)

PKA-052

Perimeter framing 25/50 x 50 x 0.7 BMT steel angle.


Shaft lining as per system table, laminated with screws or
screws and full cover adhesive.
12mm gap.
Steel Studs at 600mm maximum centres.
Wall lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

CSR 136

STUD SIZE mm
WALL LININGS

SHAFT SIDE

WALL SIDE

WFRA 21898

CSR 137
/90/90

/90/90
WFRA 21898

54/45

(c) 75 GW Partition 11kg

55/46

55/46

56/47

(d) TSB3/ASB3 Polyester

53/46

53/46

54/47

55/45

55/45

56/46

128

140

156

47/40

48/41

49/42

(b) 50 GW Partition 11kg

55/46

56/47

56/47

(c) 75 GW Partition 11kg

56/47

57/48

58/49

(d) TSB3/ASB3 Polyester

54/47

55/48

56/49

1.6

56/46

57/47

58/48

128

140

156

(a) Nil

46/39

47/40

49/42

(b) 50 GW Partition 11kg

54/45

55/46

56/47

(c) 75 GW Partition 11kg

55/46

56/47

58/49

(d) TSB3/ASB3 Polyester

53/46

54/47

56/49

55/45

56/46

58/48

128

140

156

(a) Nil

46/39

47/40

47/40

(b) 50 GW Partition 11kg

54/45

55/46

54/45

(c) 75 GW Partition 11kg

55/46

56/47

56/47

(d) TSB3/ASB3 Polyester

53/46

54/47

54/47

55/45

56/46

56/46

121

133

149

SHAFT SIDE

SHAFT SIDE
3 x 13mm GYPROCK
FYRCHEK plasterboard.
WALL SIDE
1 x 6mm CeminSeal
Wallboard.

B34

47/40

54/45

(a) Nil

1 x 13mm GYPROCK
AQUACHEK.

CSR 139

46/39

54/45

3 x 13mm GYPROCK
FYRCHEK plasterboard.

WALL SIDE

WFRA 21898

46/39

(b) 50 GW Partition 11kg

SHAFT SIDE

3 x 13mm GYPROCK
FYRCHEK plasterboard.

/90/90

(a) Nil

(e) 60

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

CSR 138

92

1 x 13mm GYPROCK
plasterboard CD.

WALL SIDE

WFRA 21898

76
Rw / Rw+Ctr

(Refer to Section A)

3 x 13mm GYPROCK
FYRCHEK plasterboard.

/90/90

64

CAVITY INFILL

Soundscreen

1.6

WALL THICKNESS mm

(e) 60

Soundscreen

WALL THICKNESS mm

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

The Red Book

Steel Frame Internal Wall Systems Laminated Services


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 142a shown)

PKA 052

Perimeter framing 25/50 x 50 x 0.7 BMT steel angle.


Shaft lining as per system table, laminated with screws or
screws and full cover adhesive.
12mm gap.
Steel Studs at 600mm maximum centres.
Wall lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

CSR 140

STUD SIZE mm
WALL LININGS

SHAFT SIDE

WALL SIDE

WFRA 21898

CSR 141
/120/120

/120/120
WFRA 21898

The Red Book

47/40

55/46

54/45

(c) 75 GW Partition 11kg

55/46

56/47

56/47

(d) TSB3/ASB3 Polyester

53/46

54/47

54/47

55/45

56/46

56/46

137

149

165

(a) Nil

47/40

49/42

49/42

(b) 50 GW Partition 11kg

55/46

57/48

56/47

(c) 75 GW Partition 11kg

56/47

58/49

58/49

(d) TSB3/ASB3 Polyester

54/47

56/49

56/49

1.6

56/46

58/48

58/48

137

149

165

(a) Nil

46/39

47/40

49/42

(b) 50 GW Partition 11kg

54/45

55/46

56/47

(c) 75 GW Partition 11kg

55/46

56/47

58/49

(d) TSB3/ASB3 Polyester

53/46

54/47

56/49

55/45

56/46

58/48

137

149

165

(a) Nil

46/39

47/40

49/42

(b) 50 GW Partition 11kg

54/45

55/46

56/47

(c) 75 GW Partition 11kg

55/46

56/47

58/49

(d) TSB3/ASB3 Polyester

53/46

54/47

56/49

1.6

55/45

56/46

58/48

130

142

158

SHAFT SIDE

1 x 13mm GYPROCK
AQUACHEK.

CSR 143

47/40

54/45

3 x 16mm GYPROCK
FYRCHEK plasterboard.

WALL SIDE

WFRA 21898

46/39

(b) 50 GW Partition 11kg

SHAFT SIDE

3 x 16mm GYPROCK
FYRCHEK plasterboard.

/120/120

(a) Nil

(e) 60

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

CSR 142

92

1 x 13mm GYPROCK
plasterboard CD.

WALL SIDE
WFRA 21898

76
Rw / Rw+Ctr

(Refer to Section A)

3 x 16mm GYPROCK
FYRCHEK plasterboard.

/120/120

64

CAVITY INFILL

SHAFT SIDE
3 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL SIDE
1 x 6mm CeminSeal
Wallboard.

Soundscreen

1.6

WALL THICKNESS mm

(e) 60

Soundscreen

WALL THICKNESS mm

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

(e) 60

Soundscreen

WALL THICKNESS mm

B35

Steel Frame Internal Wall Systems StrataWall Services


SYSTEM SPECIFICATION

ACOUSTIC
OPINION
or
TEST

TYPICAL LAYOUT (CSR 248 shown)

RP 02267S

2 x 25mm GYPROCK SHAFT LINER PANEL between


steel H-Studs at 600mm maximum centres.
Lining material as per system table laminated to Shaft
Liner Panel.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CAVITY INFILL

Rw / Rw + Ctr

(Refer to Section A)

CSR 248
FACE SIDE

/90/30

(a) Nil

36/33

1 x 13mm GYPROCK
Plasterboard CD.

WFRA 21241

WALL THICKNESS mm

64

CSR 249
/120/90
WFRA 21241

FACE SIDE

(a) Nil

36/33

1 x 13mm GYPROCK
FYRCHEK.
WALL THICKNESS mm

B36

64

The Red Book

Steel Frame External Wall Systems Steel Cladding


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 940 Shown)

ACOUSTIC
OPINION
PKA-055

Structural steel girts to engineers detail. Maximum


spacing as per system table.
GYPROCK FYRCHEK MR plasterboard, as per system
table.
Sarking
Galvanised steel battens (20mm min.) fixed through
plasterboard to steel girts.
External cladding.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

MAXIMUM GIRT
SPACING (mm)

CAVITY INFILL

600

(a) Nil

33

900

(a) Nil

34

1200

(c) Nil

36

(Refer to Section A)

Rw

CSR 940
EXTERNAL SIDE

60/60/60

2 x 16mm GYPROCK
FYRCHEK MR
plasterboard

(from outside only)


FAR2357

CSR 941
EXTERNAL SIDE

90/90/90

3 x 13mm GYPROCK
FYRCHEK MR
plasterboard

(from outside only)


FAR2357

CSR 942
120/120/120
(from outside only)
FAR2357

The Red Book

EXTERNAL SIDE
3 x 16mm GYPROCK
FYRCHEK MR
plasterboard

B37

Steel Frame External Wall Systems ExpressWall


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 934 Shown)

ACOUSTIC
OPINION
PKA-055

Cemintel Commercial ExpressWall facade system.


Sarking
Lining material to external side of structural frame, as per
system table.
Structural steel girts to engineers detail. Maximum
spacing as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

MAXIMUM GIRT
SPACING (mm)

CAVITY INFILL
(Refer to Section A)

Rw

CSR 933
EXTERNAL SIDE

//

Nil

(a) Nil

35

600

(a) Nil

38

CSR 934
60/60/60
(from outside only)
FAR2357

B38

EXTERNAL SIDE
2 x 16mm GYPROCK
FYRCHEK MR
plasterboard

The Red Book

Steel Frame External Wall Systems ExpressWall


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 932 Shown)

PKA-055

Cemintel Commercial ExpressWall facade system.


Sarking.
Lining material to external side of structural frame, as per
system table.
Steel studs at 600mm maximum centres.
Lining Material to internal side as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

STUD DEPTH mm

92

150

CAVITY INFILL (Refer to Section A)

Rw / Rw + Ctr

EXTERNAL SIDE

(a) Nil

43/36

Nil

(b) 75 Gold Batts 1.5


(c) 75 Soundscreen 2.0

CSR 932

THERMAL
Rt(WIN)

Rt(SUM)

44/38

1.8

1.5

50/43

51/45

2.5

2.3

51/43

52/45

3.1

2.8

149

207

(a) Nil

43/30

43/32

1.3

1.2

(b) 75 Gold Batts 1.5

50/37

51/39

2.7

2.4

(c) 75 Soundscreen 2.0

51/37

52/39

3.2

2.9

168

226

INTERNAL SIDE

//

1 x 13 GYPROCK
Plasterboard CD.

TYPICAL WALL THICKNESS mm

CSR 935

EXTERNAL SIDE
1 x 16mm GYPROCK
FYRCHEK MR
plasterboard

/90/90
60/60/60

INTERNAL SIDE

FAR2357

1 x 16mm GYPROCK
FYRCHEK plasterboard

TYPICAL WALL THICKNESS mm

Steel Frame External Wall Systems RendaLine


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 166 Shown)

PKA-055

External lining as per system table on 35mm top hats at


600mm max. centres.
Sarking
Structural steel girts to engineers detail.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

GIRT DEPTH mm
CAVITY INFILL (Refer to Section A)

150
Rw / Rw + Ctr

CSR 166
EXTERNAL SIDE

//

(a) Nil

TYPICAL WALL THICKNESS mm

The Red Book

27/24

1 x 8mm Cemintel
RendaLine.
193

B39

Steel Frame External Wall Systems RendaLine


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 165a shown)

PKA-055

Cemintel RendaLine sheet on timber or steel battens.


Sarking.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

STUD DEPTH mm
CAVITY INFILL (Refer to Section A)

76

THERMAL

Rw / Rw+Ctr

Rt(WIN)

Rt(SUM)

(a) Nil

38/31

1.7

1.5

INTERNAL WALL SIDE

(b) 75 Gold Batts 2.0

46/37

3.1

2.8

1 x 10mm GYPROCK
Plasterboard CD.

(c) 60 Soundscreen 1.6

45/35

2.6

2.4

CSR 165

//

WALL THICKNESS mm

SYSTEM SPECIFICATION

129

TYPICAL LAYOUT (CSR 167a shown)

ACOUSTIC
OPINION
PKA-055

Cemintel RendaLine sheet on timber or steel battens.


Sarking.
Lining material to external side as per system table.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

FRL
Report/Opinion

SYSTEM
N

CSR 167

WALL LININGS
EXTERNAL SIDE
1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.

60/60/60
(from outside only)

INTERNAL SIDE

FAR2357

STUD DEPTH mm

76

CAVITY INFILL (Refer to Section A)

Rw

Rt(WIN)

Rt(SUM)

(a) Nil

40

1.2

1.1

(b) 75 Gold Batts 1.5

46

2.6

2.4

(c) 60 Soundscreen 1.6

47

2.7

2.5

1 x 10mm GYPROCK
Plasterboard CD.

CSR 168
60/60/60
FAR2357

EXTERNAL SIDE
1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.
INTERNAL SIDE
1 x 16mm GYPROCK
FYRCHEK plasterboard.

B40

WALL THICKNESS mm

THERMAL

142

(a) Nil

42

1.2

1.1

(b) 75 Gold Batts 1.5

48

2.6

2.4

(c) 60 Soundscreen 1.6

49

2.7

2.5

WALL THICKNESS mm

148

The Red Book

Steel Frame External Wall Systems RendaLine


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 170a shown)

ACOUSTIC
OPINION
PKA-055

Cemintel RendaLine sheet on timber or steel battens.


25mm Bradford Fibertex Rockwool.
Wire mesh.
Sarking
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

FRL
Report/Opinion

SYSTEM
N

CSR 170
60/60/60
(from outside only)
FAR2357

WALL LININGS

STUD DEPTH mm
CAVITY INFILL (Refer to Section A)

60/60/60
FAR2357

THERMAL

Rw / Rw+Ctr

Rt(WIN)

Rt(SUM)

EXTERNAL SIDE

(a) Nil

40/32

1.8

1.5

As per system
specification

(b) 75 Gold Batts 1.5

45/36

2.6

2.3

INTERNAL SIDE

(c) 75 Soundscreen 2.0

45/35

3.1

2.8

1 x 10mm GYPROCK
Plasterboard CD.

CSR 171

76

WALL THICKNESS mm

129

EXTERNAL SIDE

(a) Nil

43/35

1.8

1.6

As per system
specification

(b) 75 Gold Batts 1.5

47/38

2.6

2.4

INTERNAL SIDE

(c) 75 Soundscreen 2.0

48/38

3.1

2.9

1 x 16mm GYPROCK
FYRCHEK plasterboard.

SYSTEM SPECIFICATION

WALL THICKNESS mm

135

TYPICAL LAYOUT (CSR 179a shown)

ACOUSTIC
OPINION
PKA-055

Cemintel RendaLine sheet fixed to tophats.


25mm Bradford Fibertex 450 Rockwool.
Sarking.
1 x 6mm CeminSeal Wallboard.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

FRL
Report/Opinion

SYSTEM
N

CSR 179
90/90/90
FAR2357

STUD DEPTH mm

76

CAVITY INFILL (Refer to Section A)

Rw

Rt(WIN)

Rt(SUM)

EXTERNAL SIDE

(a) Nil

45

1.3

1.2

As per system
specification

(b) 75 Gold Batts 1.5

51

2.7

2.5

INTERNAL WALL SIDE

(c) 75 Soundscreen 2.0

52

3.2

2.9

WALL LININGS

2 x 13mm GYPROCK
FYRCHEK plasterboard.

CSR 178
90/90/90
FAR2357

151

EXTERNAL SIDE
As per system
specification
INTERNAL WALL SIDE
1 x 6mm CeminSeal
Wallboard (to stud).
1 x 16mm GYPROCK
FYRCHEK plasterboard.

The Red Book

WALL THICKNESS mm

THERMAL

(a) Nil

45

1.2

1.2

(b) 75 Gold Batts 1.5

51

2.6

2.4

(c) 60 Soundscreen 1.6

52

2.7

2.5

WALL THICKNESS mm

147

B41

Steel Frame External Wall Systems Cladding On Battens


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 121a shown)

External cladding material on timber or steel battens.

PKA-055

Sarking.
Lining material to external side as per system table.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.
NOTES:
Acoustic performance valid for studs of 0.80 BMT.
*ACR = Axial Capacity Reduction.
FRL
Report/Opinion

SYSTEM
N

CSR 118

WALL LININGS
EXTERNAL SIDE OF STUD
1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.

30/30/30
(from outside only)
FAR2357

INTERNAL SIDE
1 x 10mm GYPROCK
Plasterboard CD.

CSR 121

EXTERNAL SIDE OF STUD


1 x 16mm GYPROCK
FYRCHEK MR
plasterboard.

60/60/60*
(from outside only)
*ACR 5%
FAR2357

INTERNAL SIDE
1 x 10mm GYPROCK
Plasterboard CD.

CSR 119

EXTERNAL SIDE OF STUD


2 x 13mm GYPROCK
FYRCHEK MR
plasterboard.

90/90/90
(from outside only)
FAR2357

INTERNAL SIDE
1 x 10mm GYPROCK
Plasterboard CD.

CSR 122

EXTERNAL SIDE OF STUD


1 x 16mm GYPROCK
FYRCHEK MR
plasterboard.

60/60/60
90/90/90*
*ACR 15%

INTERNAL SIDE

FAR2357

1 x 16mm GYPROCK
FYRCHEK plasterboard.

CSR 123

EXTERNAL SIDE OF STUD


2 x 16mm GYPROCK
FYRCHEK MR
plasterboard.

120/120/120
(from outside only)

INTERNAL SIDE

FAR2357

1 x 10mm GYPROCK
Plasterboard CD.

CSR 120
120/120/120
/180/180
FAR2357

EXTERNAL SIDE OF STUD


2 x 16mm GYPROCK
FYRCHEK MR
plasterboard.
INTERNAL SIDE
2 x 16mm GYPROCK
FYRCHEK plasterboard.

B42

STUD DEPTH mm
CAVITY INFILL (Refer to Section A)

76

THERMAL

Rw

Rt(WIN)

Rt(SUM)

(a) Nil

33 37

1.0

1.0

(b) 75 Gold Batts 1.5

39 43

2.4

2.2

(c) 75 Soundscreen 2.0

40 44

2.9

2.7

36 40

1.0

1.0

39 43

2.4

2.2

40 44

3.0

2.7

37 41

1.1

1.0

43 47

2.4

2.2

44 48

2.9

2.7

38 42

1.1

1.0

41 45

2.5

2.3

42 46

3.0

2.8

TYPICAL WALL THICKNESS mm


(a) Nil
(b) 75 Gold

Batts

1.5

(c) 75 Soundscreen 2.0


TYPICAL WALL THICKNESS mm
(a) Nil
(b) 75 Gold

Batts

1.5

(c) 75 Soundscreen 2.0


TYPICAL WALL THICKNESS mm
(a) Nil
(b) 75 Gold

Batts

1.5

(c) 75 Soundscreen 2.0


TYPICAL WALL THICKNESS mm

129

132

142

138

(a) Nil

37 41

1.1

1.1

(b) 75 Gold Batts 1.5

43 47

2.4

2.2

(c) 75 Soundscreen 2.0

44 48

3.0

2.7

TYPICAL WALL THICKNESS mm

148

(a) Nil

42 46

1.3

1.2

(b) 75 Gold Batts 1.5

48 52

2.6

2.4

(c) 75 Soundscreen 2.0

49 53

3.1

2.8

TYPICAL WALL THICKNESS mm

140

The Red Book

Steel Frame External Wall Systems Texture Base Sheet For Houses
SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 127a shown)

PKA-052

1 x 7.5mm Cemintel Texture Base Sheet to exterior face.


Sarking.
Lining material to external side as per system table.
Steel studs at 600mm maximum centres.
Lining material to internal side of steel studs as per system
table.
NOTES:
Acoustic performance valid for studs 0.80 BMT.
*ACR = Axial Capacity Reduction.

FRL
Report/Opinion

SYSTEM
N

CSR 127

WALL LININGS
EXTERNAL SIDE OF STUD
1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.

60/60/60
(from outside only)

INTERNAL SIDE

FAR2357

STUD DEPTH mm

EXTERNAL SIDE OF STUD


1 x 13mm GYPROCK
FYRCHEK MR
plasterboard.

60/60/60*
*ACR 15%
FAR2357

INTERNAL SIDE

(a) Nil

40/33

(b) 75 Gold Batts 1.5


(c) 75 Soundscreen 2.0

EXTERNAL SIDE OF STUD


1 x 16mm GYPROCK
FYRCHEK MR
plasterboard.

60/60/60
(from outside only)

INTERNAL SIDE

FAR2357

Rt(SUM)

42/35

0.5

0.5

46/37

48/39

1.9

1.8

47/37

49/39

2.4

2.2

107

123

41/34

42/35

0.5

0.5

47/38

48/39

1.9

1.8

48/38

49/39

2.5

2.3

113

129

(a) Nil

41/34

42/35

0.5

0.5

(b) 75 Gold Batts 1.5

47/38

48/39

1.9

1.8

(c) 75 Soundscreen 2.0

48/38

49/39

2.4

2.2

110

126

(a) Nil

42/35

44/37

0.6

0.5

(b) 75 Gold Batts 1.5

48/39

50/41

2.0

1.8

(c) 75 Soundscreen 2.0

49/39

51/41

2.5

2.3

116

132

WALL THICKNESS mm
(a) Nil
(b) 75 Gold Batts 1.5
(c) 75

60/60/60
90/90/90*
*ACR 15%
FAR2357

EXTERNAL SIDE OF STUD


1 x 16mm GYPROCK
FYRCHEK MR
plasterboard.
INTERNAL SIDE
1 x 16mm GYPROCK
FYRCHEK plasterboard.

The Red Book

Soundscreen

2.0

WALL THICKNESS mm

1 x 10mm GYPROCK CD
plasterboard.

CSR 129

THERMAL
Rt(WIN)

1 x 16mm GYPROCK
FYRCHEK plasterboard.

CSR 126

92

Rw / Rw + Ctr

1 x 10mm GYPROCK
Plasterboard CD.

CSR 128

76

CAVITY INFILL (Refer to Section A)

WALL THICKNESS mm

WALL THICKNESS mm

B43

Steel Frame External Wall Systems Concrete


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 937a Shown)

PKA-055

150mm concrete wall min 2400kg/m3.


Rondo furring channel No.129
66mm cavity.
Cavity infill as per system table.
Lining as per system table.
Notes:
Foil side to plasterboard.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CAVITY INFILL (Refer to Section A)

Rw / Rw + Ctr

THERMAL
Rt(WIN)

Rt(SUM)

CSR 937
(a) Nil

60/51

(b) Bradford Masonry Wall Blanket R1.2

65/56

2.5

2.3

INTERNAL SIDE
1 x 13mm GYPROCK
Plasterboard CD.

//

WALL THICKNESS mm

229

Steel Frame External Wall Systems Hebel Powerpanel


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

2010675.1/
2401A/R1/JH

CSR Hebel Powerpanel AAC (75mm) screw fixed to


battens spaced at 900mm maximum.
Steel studs at 600mm maximum centres.
Lining material to internal side as per system table.

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

STUD DEPTH mm

70

90

THERMAL

CAVITY INFILL (Refer to Section A)

Rw / Rw+Ctr

(a) Nil

46/40

(b) 90 Gold Batts 2.0

Rt(WIN)

Rt(SUM)

46/40

0.9

0.9

53/44

53/45

2.8

2.6

177

197

HEBEL 1401
240/180/180
(from outside only)
FSV0356

INTERNAL SIDE
1 x 10mm GYPROCK
Plasterboard CD.

WALL THICKNESS mm

B44

The Red Book

Steel Frame External Wall Systems Masonry


SYSTEM SPECIFICATION

TYPICAL LAYOUT (CSR 185a shown)

ACOUSTIC
OPINION
PKA-055

Fire rated masonry veneer wall.


Steel studs at 600mm maximum centres with 40mm
minimum gap to masonry.
Lining material as per system table.
Notes:
Masonry to be minimum 90mm thick and 170kg/m2

FRL
Report/Opinion

SYSTEM
N

CSR 184
FRL
60/60/60
from outside only
refer to
Masonry
Manufacturer

FAR 2357
and refer to
Masonry
Manufacturer

CSR 186

FAR 2357
and refer to
Masonry
Manufacturer

The Red Book

(b) 75 Gold Batts 1.5


(c) 88

Soundscreen

2.5

TYPICAL WALL THICKNESS mm

92

THERMAL

Rw / Rw+Ctr

Rt(WIN)

Rt(SUM)

52/44

0.5

0.5

59/51

2.1

2.0

59/50

3.2

2.9

252

EXTERNAL WALL SIDE

(a) Nil

55/48

0.6

0.6

Masonry veneer wall with


FRL 60/60/60.

(b) 75 Gold Batts 1.5

62/55

2.2

2.0

INTERNAL WALL SIDE

(c) 88 Soundscreen 2.5

62/54

3.2

2.9

TYPICAL WALL THICKNESS mm

258

EXTERNAL WALL SIDE

(a) Nil

55/48

0.6

0.6

Masonry veneer wall with


FRL 90/90/90.

(b) 75 Gold Batts 1.5

62/55

2.2

2.0

INTERNAL WALL SIDE

(c) 88 Soundscreen 2.5

62/54

3.3

3.0

58/51

0.7

0.7

65/58

2.2

2.1

65/57

3.3

3.0

2 x 13mm GYPROCK
FYRCHEK plasterboard.

CSR 187

FAR 2357
and refer to
Masonry
Manufacturer

(a) Nil

1 x 16mm GYPROCK
FYRCHEK plasterboard.

FRL
90/90/90

CAVITY INFILL (Refer to Section A)

Masonry veneer wall with


FRL 60/60/60.
1 x 10mm GYPROCK
plasterboard CD.

CSR 185

STUD DEPTH mm

EXTERNAL WALL SIDE

INTERNAL WALL SIDE

FRL
60/60/60

FRL
120/120/120

WALL LININGS

EXTERNAL WALL SIDE

TYPICAL WALL THICKNESS mm


(a) Nil

Masonry veneer wall with


FRL 90/90/90.

(b) 75 Gold

INTERNAL WALL SIDE

(c) 88 Soundscreen 2.5

2 x 16mm GYPROCK
FYRCHEK plasterboard.

Batts

1.5

TYPICAL WALL THICKNESS mm

268

274

B45

Column or Beam Systems

FIG B1: TYPICAL CONSTRUCTION DETAILS


(CSR 195 SHOWN)
Metal Angle fixed to soffit at
600mm maximum centres and
100mm maximum from each end

SYSTEM SPECIFICATION

Steel angle fixed to the soffit or wall junction.


CSR Gyprock Universal Encasement Clips friction fitted
to the remaining column/beam flanges.
Wall Furring Track (Rondo N140/142) is held in the back
tongue of the clip.

6-20mm gap

Noggings at each end of the column/beam and behind


plasterboard butt joints in single layer systems.

Caulk all gaps


with Gyprock Fire
Mastic/FB1

Lining material as per system table.


FRL
Report/Opinion

SYSTEM
N

CSR Gyprock
Universal
Encasement Clips

PLASTERBOARD
LINING

Rondo Wall Furring


Track clipped along
flanges of beam

CSR 192
30//

1 x 13mm GYPROCK
FYRCHEK
plasterboard.

CSIRO
FCO 1494

Each layer of
GYPROCK
FYRCHEK
plasterboard fixed at
200mm maximum
centres to all
framing

CSR 193
60//

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

CSIRO
FCO 1494

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

CSIRO
FCO 1494

Apply External
Corner Bead and
set all corners
Rondo Track
fixed to column
at ends and
800mm max.
centres

CSR 195
90//

FIXING TO STEEL HOLLOW SECTION

RHS/SHS
Steel Column
18mm

Each layer of
GYPROCK FYRCHEK
plasterboard fixed at
200mm maximum
centres to all tracks

CSR 196
120//
CSIRO
FCO 1494

3 x 13mm GYPROCK
FYRCHEK
plasterboard.

FIXING TO STEEL UNIVERSAL BEAM


CSR Gyprock Universal
Encasement Clips at
800mm maximum centres
along column flanges and
150mm maximum from
each end of column

Rondo Wall Furring


Track held in back
tongue of CSR
Gyprock Universal
Encasement Clips

Screw fix each


layer at 200mm
maximum centres
to all steel framing

Offset Butt Joints in


consecutive layers by
300mm minimum
Fasten at butt joints
with laminating screws
at 200mm max centres

200mm max.

Apply External Angle


Bead to all corners and
set

B46

The Red Book

EC08 Plasterboard Systems


The growth in recent years of more sustainable development,
the Green Building Council Australia and Green Star ratings
for buildings has fuelled the demand for more environmentally
responsible building materials.
In the plasterboard market, Gyprock has led the way
with reCore technology and the Gyprock EC08 range
of Good Environmental Choice Australia (GECA) certified
plasterboards.
CSR Lightweight Systems manufactures and supplies a
diverse range of plasterboard and fibre cement sheets,

acoustic panels and accessories to suit a multitude of wall,


ceiling and encasement applications.
The Gyprock EC08 range of plasterboard has been
developed using Gyprocks reCore technology which
enables the use of higher levels of recycled content over
20% for EC08 Impact.
All products in the range have been certified by GECA as
meeting the requirements of their environmental standard
for Panel Boards.

EC08 Partition

EC08 Fire

EC08 Impact

An economical, non-fire rated


board for general requirements
where fire and acoustics
are not required.

The original, GECA certified


EC08 board with fire and
acoustic rating for party walls
and meeting rooms.

Fire and acoustic rated with


impact resistance for high traffic
areas such as in education
and health facilities.

The Red Book

B47

Steel Frame Internal Wall Systems Single Stud ECO8


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR EC105a shown)

PKA-056

Lining material as per system table.


Steel studs at 600mm maximum centres.
Lining material as per system table.
NOTES:
Acoustic performance valid for 0.5 BMT.

FRL
Report/Opinion

SYSTEM
N

STUD DEPTH mm
WALL LININGS

BOTH SIDES
1 x 13mm GYPROCK
ECO8 Partition.

SIDE ONE
1 x 6mm CeminSeal
Wallboard.

//

CSR EC110

//

39/30 41/32 42/33 43/34 45/36

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester

CSR EC620

//

B48

90

102

118

176

39/30 41/32 42/33 43/34 45/36

(c) 75 GW Partition 11kg

WALL THICKNESS mm

43/34 43/34 44/35 46/37

38/31 40/33 41/34 42/35 44/37

70

42/32 43/33 44/34 46/36


83

95

111

169

(a) Nil

39/32 40/33 42/35 43/36 46/39

(b) 50 GW Partition 11kg

44/35 45/36 47/38 48/39 50/41

(c) 75 GW Partition 11kg

SIDE TWO

(d) TSB3/ASB3 Polyester


(e) 60 Soundscreen 1.6

47/38 48/39 49/40 51/42

44/37 44/37 46/39 47/40 49/42

46/36 48/38 49/39 51/41

WALL THICKNESS mm
(a) Nil

42/35 43/36 44/37 46/40 48/42

(b) 50 GW Partition 11kg

47/38 48/39 49/40 51/43 52/44

(c) 75 GW Partition 14kg


(d) TSB3/ASB3 Polyester

50/41 50/41 52/44 53/45

46/39 47/40 48/41 50/44 51/45

(e) 60 Soundscreen 1.6

103

49/39 50/40 52/43 53/44


116

128

144

202

(a) Nil

37/27 37/30 38/31 40/33 43/36

(b) 50 GW Partition 11kg

40/30 42/33 43/34 45/36 47/38

(c) 75 GW Partition 11kg

SIDE TWO

(d) TSB3/ASB3 Polyester

40/32 41/34 42/35 44/37 46/39

1 x 13mm GYPROCK
ECO8 Impact

(e) 60 Soundscreen 1.6

SIDE ONE
1 x 13mm GYPROCK
Plasterboard CD.

//

77

42/32 43/33 44/34 46/36

34/27 36/29 37/30 38/31 41/34

WALL THICKNESS mm

CSR EC305

(b) 50 GW Partition 11kg

2 x 13mm GYPROCK
ECO8 Partition

2 x 13mm GYPROCK
ECO8 Partition

//

43/34 43/34 44/35 46/37

(a) Nil

(e) 60 Soundscreen 1.6

BOTH SIDES

38/31 40/33 41/34 42/35 44/37

(e) 60 Soundscreen 1.6

1 x 13mm GYPROCK
ECO8 Partition.

CSR EC115

150

34/27 36/29 37/30 38/31 41/34

(d) TSB3/ASB3 Polyester

1 x 13mm GYPROCK
ECO8 Partition

92

(b) 50 GW Partition 11kg

SIDE TWO

SIDE ONE

76

(a) Nil

WALL THICKNESS mm

CSR EC605

64

Rw / Rw+Ctr

(Refer to Section A)

CSR EC105

//

51

CAVITY INFILL

WALL THICKNESS mm

77

44/35 44/35 46/37 48/39


43/33 44/34 46/36 48/38
90

102

118

176

(a) Nil

36/29 38/31 38/31 40/33 43/36

(b) 50 GW Partition 11kg

41/32 43/34 43/34 45/36 47/38

(c) 75 GW Partition 14kg

SIDE TWO

(d) TSB3/ASB3 Polyester

40/33 42/35 42/35 44/37 46/39

1 x 13mm GYPROCK
ECO8 Impact

(e) 60 Soundscreen 1.6

SIDE ONE
1 x 6mm CeminSeal
Wallboard.

WALL THICKNESS mm

70

46/37 45/36 47/38 49/40


44/34 44/34 46/36 48/38
83

95

111

169

The Red Book

Steel Frame Internal Wall Systems Single Stud ECO8


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR EC310a shown)

PKA-056

Lining material as per system table.


Steel studs at 600mm maximum centres.
Lining material as per system table.
NOTES:
Acoustic performance valid for 0.5 BMT.

FRL
Report/Opinion

SYSTEM
N

STUD DEPTH mm
WALL LININGS

BOTH SIDES
1 x 13mm GYPROCK
ECO8 Impact.

FAR 2357
&
EWFA 24040

- /60/60

BOTH SIDES
1 x 13mm GYPROCK
ECO8 Fire.

FAR 2357
&
BWA 23035

CSR EC615
- /60/60
FAR 2357
&
BWA 23035

1 x 13mm GYPROCK
ECO8 Fire.

CSR EC210

43/34 44/35 45/36 46/37 48/40

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

- /90/90
FAR 2357
&
BWA 23035

- /120/120

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

FAR 2357
&
BWA 23035

2 x 13mm GYPROCK
ECO8 Fire.

(d) TSB3/ASB3 Polyester

WALL THICKNESS mm

176

45/36 44/35 46/37 48/40

41/34 42/35 42/35 44/37 46/40

77

44/34 44/34 46/36 48/39


90

102

118

176

48/39 48/39 49/40 51/43

44/37 45/38 46/39 47/40 49/43

83

47/37 48/38 49/39 51/42


96

108

124

182

(a) Nil

40/33 42/35 43/36 44/37 47/41

(b) 50 GW Partition 11kg

45/36 47/38 48/39 49/40 51/43

(c) 75 GW Partition 14kg

WALL THICKNESS mm

50/41 50/41 51/42 53/45

44/37 46/39 47/40 48/41 50/44

90

48/38 49/39 50/40 52/43


103

115

131

189

(a) Nil

45/38 47/41 48/42 48/42 50/44

(b) 50 GW Partition 11kg

50/41 52/44 53/45 53/45 54/46

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6

54/46 54/46 54/46 55/47

49/42 51/45 52/46 52/46 53/47

103

53/44 54/45 54/45 55/46


116

128

144

202

(a) Nil

44/37 45/38 46/40 47/41 49/43

(b) 50 GW Partition 11kg

49/40 50/41 51/43 52/44 53/45

(c) 75 GW Partition 11kg


(d) TSB3/ASB3 Polyester
(e) 60 Soundscreen 1.6
WALL THICKNESS mm

The Red Book

118

45/36 46/37 47/38 48/39 50/42

(e) 60 Soundscreen 1.6

BOTH SIDES

102

(b) 50 GW Partition 11kg

WALL THICKNESS mm

- /120/120

90

40/33 41/34 42/35 43/36 46/40

(d) TSB3/ASB3 Polyester

CSR EC215

77

45/35 46/36 47/37 49/40

(a) Nil

SIDE TWO

2 x 13mm GYPROCK
ECO8 Impact.

FAR 2357
&
EWFA 24040

42/33 44/35 44/35 46/37 48/40

2 x 13mm GYPROCK
ECO8 Fire.

BOTH SIDES

42/35 43/36 44/37 45/38 47/41

36/29 38/31 38/31 40/33 43/37

(e) 60 Soundscreen 1.6

CSR EC315

46/37 46/37 47/38 49/41

(b) 50 GW Partition 14kg

SIDE TWO

1 x 13mm GYPROCK
ECO8 Fire.

(a) Nil

1 x 6mm CeminSeal
Wallboard.

SIDE ONE

150

(b) 50 GW Partition 11kg

(c) 75 GW Partition 11kg

1 x 13mm GYPROCK
ECO8 Fire.

92

38/31 39/32 40/33 41/34 44/38

WALL THICKNESS mm
SIDE ONE

76

(a) Nil

WALL THICKNESS mm

CSR EC205

64

Rw / Rw+Ctr

(Refer to Section A)

CSR EC310
- /60/60

51

CAVITY INFILL

52/43 52/44 53/45 54/46

48/41 49/42 50/44 51/45 52/46

103

51/41 52/43 53/44 54/45


116

128

144

202

B49

Steel Frame Internal Wall Systems Staggered Stud ECO8


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR EC220a shown)

PKA-056

Lining material as per system table.


Staggered Steel Studs at 600mm max. centres each side.
64mm Rondo lipped steel stud, located in 92mm track
top and bottom, using the Gyprock Staggered Stud Clip.
Lining material as per system table.

FRL
Report/Opinion

SYSTEM
N

CAVITY WIDTH mm
WALL LININGS

FAR 2357
&
BWA 23035

39/32

41/34

44/38

(b) 50 GW Partition 11kg

47/38

49/40

51/43

BOTH SIDES

(c) 75 GW Partition 11kg

48/39

50/41

52/44

1 x 13mm GYPROCK
ECO8 Fire

(d) TSB3/ASB3 Polyester

46/39

48/41

50/44

(e) 60 Soundscreen 1.6

48/38

50/40

52/43

102

118

176

(a) Nil

41/34

42/35

45/39

(b) 50 GW Partition 11kg

49/40

50/41

52/44

BOTH SIDES

(c) 75 GW Partition 11kg

50/41

51/42

53/45

1 x 13mm GYPROCK
ECO8 Impact

(d) TSB3/ASB3 Polyester

48/41

49/42

51/45

1.6

50/40

51/41

53/44

102

118

176

CSR EC320

FAR 2357
&
EWFA 24040

(e) 60

Soundscreen

WALL THICKNESS mm

B50

150

(a) Nil

WALL THICKNESS mm

- /60/60

92
Rw / Rw+Ctr

(Refer to Section A)

CSR EC220
- /60/60

76

CAVITY INFILL

The Red Book

Steel Frame Internal Wall Systems Double Stud ECO8


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR 325a shown)

PKA-056

Lining material as per system table.


Discontinuous
Construction

2 Rows of Steel Studs at 600mm maximum centres with


20mm minimum gap.
Lining material as per system table.
NOTES:
Unless otherwise specified, cavity infill is required in one
stud row only.

FRL
Report/Opinion

SYSTEM
N

CAVITY WIDTH mm
WALL LININGS

BOTH SIDES
2 x 13mm GYPROCK
ECO8 Impact.

FAR 2357
&
EWFA 24040

CAVITY INFILL

CSR EC225
BOTH SIDES

FAR 2357
&
BWA 23035

2 x 13mm GYPROCK
ECO8 Fire.

250

300

Rw / Rw+Ctr

(a) Nil

51/45

53/47

54/48

54/48

(b) 50 GW Partition 11kg

59/51

61/53

62/54

62/54

(c) 75 GW Partition 11kg

61/53

62/54

63/55

63/55

(d) TSB3/ASB3 Polyester

58/52

60/54

61/55

61/55

60/51

62/53

63/54

63/54

200

252

302

352

(a) Nil

50/44

51/45

52/46

53/47

(b) 50 GW Partition 11kg

58/50

59/51

60/52

61/53

(c) 75 GW Partition 11kg

60/52

60/52

61/53

62/54

(d) TSB3/ASB3 Polyester

57/51

58/52

59/53

60/54

(e) 60 Soundscreen 1.6

59/50

60/51

61/52

62/53

200

252

302

352

(e) 60

Soundscreen

1.6

WALL THICKNESS mm

/120/120

200

(Refer to Section A)

CSR EC325
/120/120

148

WALL THICKNESS mm

Steel Frame Internal Wall Systems SecurityWall ECO8


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR EC230a shown)

PKA-054

Lining material as per system table.

Discontinuous
Construction

Gyprock SecurityWall Panel 50.


Cavity determined by track width.
Gyprock SecurityWall Panel 50.
Lining material as per system table.
NOTES:
^ SecurityWall Panel ribs offset to enable insulation to fit.

FRL
Report/Opinion

SYSTEM
N

TRACK WIDTH mm
WALL LININGS

FAR 2039
&
BWA 23035

BOTH SIDES
1 x 13mm GYPROCK
ECO8 Fire.

64

(a) Nil

48/40

50/42

51/43

(b) 50 GW Partition 11kg

55/47^

57/49

58/50

(c) 75 GW Partition 11kg

58/50^

59/51

(d) TSB2/ASB2 Polyester

53/45^

55/47

56/48

WALL THICKNESS mm

The Red Book

51
Rw / Rw+Ctr

(Refer to Section A)

CSR EC230
- /60/60

28

CAVITY INFILL

154

177

190

B51

Steel Frame Internal Wall Systems Laminated Services ECO8


SYSTEM SPECIFICATION EC08 Systems

ACOUSTIC
OPINION

TYPICAL LAYOUT (CSR EC031 shown)

PKA-056

Perimeter Framing 25/50 x 50 x 0.8 BMT steel angle.


3 x Gyprock EC08 Fire laminated with screws(S) or
screws and full cover adhesive (SA)

FRL
Report/Opinion

SYSTEM
N

WALL LININGS

CAVITY INFILL
(Refer to Section A)

Rw

(a) Nil

35

CSR EC031
- /90/90
FC0 1786
&
BWA 23035

B52

LINING
3 x 13mm GYPROCK
ECO8 Fire.

The Red Book

FIG B2: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS


HORIZONTAL SHEETING ADHESIVE/FASTENER FIXING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
NON-FIRE RATED
Fixing Specifications

For Level 4 finish, form butt


joints between framing

Screw
along sheet
centreline
at every
second
stud
200mm
min.

One layer of Gyprock


plasterboard to each side
of wall

Daubs of CSR Gyprock


Acrylic Stud Adhesive

300mm
max.

Screws
Adhesive

Refer to Section A

Location

Fixing & Spacing

Field
Sheet
Width
900mm
1200mm
1350mm

Adhesive Daubs at
300mm max. centres
and 200mm min.
from fastener points
3 daubs
4 daubs
5 daubs
Screw at every
second stud along
sheet centreline

Recessed
Edges

Screw at each stud

Butt joints

Screws at 200mm
centres

Corners &
Openings

Screws at 300mm
max. centres

SUITABLE FOR:

200mm
max.

300mm
max.

300mm
max.

CSR Bradford Acoustic


Insulation if required

200mm
min.

Refer to perimeter details

Noggings may not be permitted


in staggered stud systems

FIG B3: FASTENER FIXING SINGLE LAYER HORIZONTAL SHEETING NON-TILED AREAS

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
NON-FIRE RATED
Fixing Specifications
For Level 4 finish, form butt
joints between framing

400mm
max.

300mm
max.

One layer of Gyprock


plasterboard to each side
of wall

Screws

Refer to Section A

Location

Fixing & Spacing

Field

Screws at 400mm
max. centres

Sheet
Width
900mm
1200mm
1350mm

4 Screws
4 Screws
5 Screws

Recessed
Edges

Screw at each stud

Butt joints

Screws at 200mm
max. centres

Corners &
Openings

Screws at 300mm
max. centres

SUITABLE FOR:
200mm
max.

CSR Bradford Acoustic


Insulation if required
Refer to perimeter
details

Noggings may not be permitted


in staggered stud systems

The Red Book

B53

FIG B4: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS


VERTICAL SHEETING ADHESIVE/FASTENER FIXING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
NON-FIRE RATED
Fixing Specifications
Screws
Adhesive

Refer to Section A

Location

Fixing & Spacing

Field

Adhesive Daubs at
300mm max. centres
and 200mm min.
from fastener points
Screw at top and
bottom and 1200mm
max. cts

Recessed
Edges

Screw at top and


bottom and 400mm
max. cts

Corners &
Openings

Screws at
300mm max. centres

300mm
max.
400mm
max.
300mm
max.

200mm
min.

CSR Bradford Acoustic


Insulation if required

Screw at
1200mm
max.
vertical
centres

Daubs of CSR Gyprock


Acrylic Stud Adhesive

One layer of Gyprock


plasterboard to each side
of wall

SUITABLE FOR:

300mm
max.

Refer to perimeter details

200mm
min.
Noggings may not be permitted
in staggered stud systems

FIG B5: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS


VERTICAL SHEETING ADHESIVE/FASTENER FIXING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
NON-FIRE RATED
Fixing Specifications
200mm
max.

Two layers of Gyprock


plasterboard to each side
of wall

300mm
max.

400mm
max.
CSR Bradford Acoustic
Insulation if required

Daubs of CSR Gyprock


Acrylic Stud Adhesive

400mm
max.

200mm
min.
Screw at
1200mm
max.
vertical
centres

Screws
Adhesive

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges &
Field

Screws at top and


bottom and at
400mm max. centres

2nd Layer

Fixing & Spacing

Field

Adhesive Daubs at
300mm max. centres
and 200mm min.
from fastener points.
Screw at top and
bottom and 1200mm
max.cts

Recessed
Edges

Screw at top and


bottom and 400mm
max. cts

Corners &
Openings

Screws at 300mm
max. centres

SUITABLE FOR:
300mm
max.

400mm
max.

Refer to perimeter details

Noggings may not be permitted


in staggered stud systems

B54

The Red Book

FIG B6: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS CEMINSEAL WALLBOARD NON-TILED AREAS
HORIZONTAL SHEETING ADHESIVE/FASTENER FIXING

For additional information, refer to FC101, Cemintel Wet Area Systems.


Temporary fastener through
block at every second stud
until adhesive sets

One layer of CeminSeal


wallboard to each side of
wall

200mm
max.

NON-FIRE RATED
Fixing Specifications
Screws
Adhesive

Refer to Section A

Location

Fixing & Spacing

Field
Sheet
Width
900mm
1200mm
1350mm

Adhesive Daubs at
230mm max. centres
and 200mm min.
from fastener points
3 daubs
4 daubs
5 daubs
Screw through
temporary block
at every second
stud along sheet
centreline

Recessed
Edges

Screw at each stud

Butt joints

Screws at 200mm
centres

Corners &
Openings

Screws at 200mm
max. centres

Daubs of GYPROCK
Acrylic Stud Adhesive

200mm
max.

230mm
max.

SUITABLE FOR:

230mm
max.

CSR Bradford Acoustic


Insulation if required

200mm
min.

Refer to perimeter details

Fasteners at 12mm min. from


sheet edges and 50mm min.
from sheet corners

Noggings may not be permitted


in staggered stud systems

FIG B7: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS CEMINSEAL WALLBOARD NON-TILED AREAS
HORIZONTAL SHEETING FASTENER FIXING

For additional information, refer to FC101, Cemintel Wet Area Systems.


NON-FIRE RATED
Fixing Specifications

One layer of CeminSeal


wallboard to each side of
wall

200mm
max.
300mm
max.

Screws

Refer to Section A

Location

Fixing & Spacing

Field

Screws at 300mm
max. centres

Sheet
Width
900mm
1200mm
1350mm

4 Screws
5 Screws
6 Screws

Recessed
Edges

Screw at each stud

Butt joints

Screws at 200mm
max. centres

Corners &
Openings

Screws at 300mm
max. centres

SUITABLE FOR:
200mm
max.

CSR Bradford Acoustic


Insulation if required
Refer to perimeter details

Noggings may not be permitted


in staggered stud systems
Fasteners at 12mm min. from
sheet edges and 50mm min.
from sheet corners

The Red Book

B55

FIG B8: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS SINGLE LAYER VERTICAL SHEETING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
200mm max.

Fixing Specifications

Noggings behind but joints


staggered 600mm min.

Screws

CSR Bradford Acoustic


Insulation if required

300mm
max.

600mm
min.

Refer to Section A

Location

Fixing & Spacing

Field

Screws at 300mm
max. centres

Recessed
Edges

Screws at
300mm max. centres

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

SUITABLE FOR:

300mm
max.

300mm
max.

One layer of GYPROCK


FYRCHEK plasterboard
to each side of wall in
accordance with system
specifications

Noggings may not be permitted


in staggered stud systems

Refer to perimeter
details

FIG B9: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS SINGLE LAYER HORIZONTAL SHEETING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.

FIRE RATED
Fixing Specifications
Screws

300mm
max.
300mm
max.

Recessed joints to be
offset a minimum 300mm
in opposing sides when not
backed by nogging

One layer of GYPROCK


FYRCHEK plasterboard to
each side of wall

Refer to Section A

Location

Fixing & Spacing

Field

Screws at 300mm
max. centres

Recessed
Edges

Screw at
each stud

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

SUITABLE FOR:
200mm
max.

200mm
max.

CSR Bradford Acoustic


Insulation if required

Refer to perimeter
details

B56

Noggings may not be permitted


in staggered stud systems

The Red Book

FIG B10: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS TWO LAYER VERTICAL SHEETING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
Fixing Specifications

300mm
max.
CSR Bradford Acoustic
Insulation if required

600mm
max.

200mm max.
laminating screws

Two layers of GYPROCK


FYRCHEK plasterboard
to each side of wall in
accordance with system
specifications

Screws

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges
& Field

Screws at 600mm
max. centres

2nd Layer

Fixing & Spacing

Field

Screws at 300mm
max. centres

Recessed
Edges

Screws at
300mm max. centres

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

SUITABLE FOR:

200mm
max.
300mm
max.

300mm
max.

Noggings behind but joints


staggered 600mm min.

Refer to perimeter
details
Noggings may not be permitted
in staggered stud systems

FIG B11: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS TWO LAYER VERTICAL+HORIZONTAL SHEETING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
Fixing Specifications
200mm
max.

CSR Bradford Acoustic


Insulation if required

300mm
max.
300mm
max.

600mm
max.

600mm
max.

The Red Book

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges
& Field

Screws at 600mm
max. centres

2nd Layer

Fixing & Spacing

Field

Screws at 300mm
max. centres

Recessed
Edges

Screw at
each stud

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

SUITABLE FOR:

Two layers of GYPROCK


FYRCHEK plasterboard
to each side of wall in
accordance with system
specifications

Refer to perimeter
details

Screws

Where butt
joints are
formed off
studs, laminate
to first layer
with laminating
screws at
200mm max.

Noggings may not be permitted


in staggered stud systems

B57

FIG B12: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS TWO LAYER HORIZONTAL SHEETING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
Stagger fasteners
at butt joints

FIRE RATED
Fixing Specifications

Stagger horizontal joints


300mm minimum between
1st and 2nd layer
200mm
max.
300mm
max.
300mm min.

CSR Bradford Acoustic


Insulation if required

Studs at 600mm maximum


centres

300mm
max.

600mm
max.
Two layers of GYPROCK
FYRCHEK plasterboard
to each side of wall in
accordance with system
specifications

Stagger butt joints in


adjacent sheets and
between 1st and 2nd
layers by one stud
minimum

Refer to perimeter
details

B58

Screws

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges &
Field

Screws at 600mm
max. centres

2nd Layer

Fixing & Spacing

Field

Screws at 300mm
max. centres

Recessed
Edges

Screw at
each stud

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

SUITABLE FOR:

Where butt
joints are
formed off
studs,
laminate to
first layer
with
laminating
screws at
200mm
max.
Noggings may not be permitted
in staggered stud systems

The Red Book

FIG B13: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS


THREE LAYER VERTICAL OR HORIZONTAL SHEETING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.
FIRE RATED
Fixing Specifications for
Vertical Sheeting (shown)

600mm

Offset all joints 300mm


min. from previous
layer

300mm

600mm

300mm

Screws

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges,
Field,
Corners &
Openings

Screws at 600mm
max. centres on
studs

2nd Layer

Fixing & Spacing

Recessed
Edges
Field

Screws at 300mm
max. centres on
studs

Butt Joints

Laminating Screws at
200mm max. centres

Corners &
Openings

Screws at 300mm
max. centres

3rd Layer

Fixing & Spacing

Recessed
Edges,
Field, Butt
Joints
Corners &
Openings

Laminating screws
at 400x400mm max.
grid

FIRE RATED
400mm

400mm
Refer to perimeter
details
400mm

Fixing Specifications for


Horizontal Sheeting
Screws

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges,
Field,
Butt Joints,
Corners &
Openings

Screws at 600mm
max. centres on
studs

2nd Layer

Fixing & Spacing

Recessed
Edges

Screws at 600mm
max. centres on
studs

Field

Screws at 300mm
max. centres on
studs

Corners &
Openings

Screws at 300mm
max. centres

Butt Joints

Screws at 200mm
max. centres on
studs

3rd Layer

Fixing & Spacing

Recessed
Edges,
Field, Butt
Joints
Corners &
Openings

Laminating screws
at 400x400mm max.
grid

SUITABLE FOR:

The Red Book

B59

FIG B14: INSTALLATION DETAIL FOR STEEL FRAME EXTERNAL WALL SYSTEM
TWO OR THREE LAYER VERTICAL SHEETING

For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide.

200mm

400mm
200mm

Refer to
system table
for girt spacing
200mm

Offset all joints by


300mm minimum
200mm

400mm

200mm

FIRE RATED
Fixing Specifications for
Vertical Sheeting (shown)
Screws

B60

SUITABLE FOR:

Refer to Section A

1st Layer

Fixing & Spacing

Field &
Butt Joints

Screws at 200mm
max. centres to all
girts

2nd & 3rd


Layers

Fixing & Spacing

Recessed
Edges &
Butt Joints

Laminating Screws at
200mm max. centres

Field

Laminating Screws at
400 x 400mm max.
grid

The Red Book

FIG B15: INSTALLATION DETAIL FOR INTERNAL WALL SYSTEMS


ONE, TWO OR THREE LAYER VERTICAL OR HORIZONTAL SHEETING

For additional information, refer to GYP546, Gyprock Shaft Systems.


FIRE RATED
Set Joints in at
least one layer

Lost
studs

Fixing Specifications for


Vertical Sheeting (shown)

35 x 35 x 0.8mm
angle screw fixed at
400mm centres to
each stud

First layer

600mm
Nogging as required

600mm

Fix first side as for


second side
300mm

Screws

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges,
Field,
Corners &
Openings

Screws at 600mm
max. centres on
studs

2nd Layer

Fixing & Spacing

Recessed
Edges
Field

Screws at 300mm
max. centres on
studs

Butt Joints

Laminating Screws at
200mm max. centres

Corners &
Openings

Screws at 300mm
max. centres

3rd Layer

Fixing & Spacing

Recessed
Edges,
Field, Butt
Joints
Corners &
Openings

Laminating screws
at 400x400mm max.
grid

300mm

FIRE RATED
Fixing Specifications for
Horizontal Sheeting

400mm

Refer to
perimeter
details

400mm

400mm

Offset all joints


300mm min. from
previous layer

SUITABLE FOR:

Set outer
layer joints
from
accessible
side

Screws

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges,
Field,
Butt Joints,
Corners &
Openings

Screws at 600mm
max. centres on
studs

2nd Layer

Fixing & Spacing

Recessed
Edges

Screws at 600mm
max. centres on
studs

Field

Screws at 300mm
max. centres on
studs

Corners &
Openings

Screws at 300mm
max. centres

Butt Joints

Screws at 200mm
max. centres on
studs

3rd Layer

Fixing & Spacing

Recessed
Edges,
Field, Butt
Joints
Corners &
Openings

Laminating screws
at 400x400mm max.
grid

NOTE: Fix single layer systems as


shown for 2nd layer

Alternative stud
type for in-line
stud framing

The Red Book

B61

FIG B16: INSTALLATION DETAIL FOR SHAFTWALL SYSTEMS

For additional information, refer to GYP546, Gyprock Shaft Systems.


Staggered Joints

FIRE RATED
Fixing Specifications for
Vertical Sheeting (shown)

J Track
C-H Studs

300mm
max.

25mm GYPROCK
Shaft Liner Panels

600mm
max.

300mm
max.

Screws

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges, &
Field

Screws at 600mm
max. centres on
studs

2nd Layer

Fixing & Spacing

Field

Screws at 300mm
max. centres

Recessed
Edges

Screws at
300mm max. centres

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

IMPORTANT
300mm
max.

1st layer of
GYPROCK FYRCHECK
plasterboard

Walls enclosing lift shafts MUST


have both layers of GYPROCK
FYRCHEK separately fastened to the
top and bottom J tracks with screws
at 300mm maximum spacings.

600mm
max.

Refer to perimeter details

2nd layer of GYPROCK


FYRCHECK plasterboard
J Track

FIG B17: INSTALLATION DETAIL FOR LAMINATED SERVICE SYSTEMS

For additional information, refer to GYP546, Gyprock Shaft Systems.


CSR Gyprock Fire Mastic at
head of 2nd layer

FIRE RATED

75mm

IBS Backing
Rod at head
of 1st layer

Steel Angle
internal
framing

400mm
max.

Fix 1st layer to vertical


steel angles only
NOTE: * Adhesive required for
systems CSR967-SA, CSR968-SA
and CSR969-SA only.

75mm

600mm max.

400mm
max.

Apply adhesive*
and screw fix
2nd layer to
vertical steel
angles with
25/45mm
Gyprock screws.
Fix body with
laminating
screws at
600mm max.
horizontal x
400mm max.
vertical centres

Apply adhesive*
and screw fix
body of 3rd
layer with
laminating
screws only at
600mm max.
horizontal x
400mm max.
vertical centres

CSR Gyprock Fire Mastic


at base of 3rd layer
Steel angle frame installed over
first layer of plasterboard at floor,
soffit and vertical corners

B62

The Red Book

FIG B18: INSTALLATION DETAIL STEEL FRAME SECURITYWALL SYSTEM

For additional information, refer to GYP560, Gyprock SecurityWall Systems.

SecurityWall
Track 27

FIRE RATED
300mm
max.

Gyprock
SecurityWall
Panel 27

1x 13mm
GYPROCK
FYRCHEK
plasterboard

Fixing Specifications for


Vertical Sheeting (shown)
Screws

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges, &
Field

Screws at 600mm
max. vertical centres
x 300mm max.
horizontal centres

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

600mm
max.

Cavity
Insulation
Blanket

Base Track

300mm
max.

Caulk all perimeter gaps


with Gyprock Fire Mastic

FIG B19: INSTALLATION DETAIL STEEL FRAME SECURITYWALL SYSTEM

For additional information, refer to GYP560, Gyprock SecurityWall Systems.

FIRE RATED

Security Wall
Track 27

Fixing Specifications for


Vertical Sheeting (shown)

Steel Stud Profiles as


per system table at
600mm centres or
Gyprock SecurityWall
Panel 50

Screws
Adhesive

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges, &
Field

Screws at 600mm
max. vertical centres
to all stud profiles
OR
Screws at 600mm
max. vertical centres
and 300mm max.
horizontal centres to
steel sheeting

200mm
min.

2nd Layer

Fixing & Spacing

Recessed
Edges

Screws at corners
and 600mm max. cts

300mm
max.

Field

Rows of Adhesive
Daubs at 600mm
max. horizontal cts x
300mm max. vertical
cts and 200mm min.
from fastener points
Screw along
centreline at 1200mm
max. cts

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

300mm
max.

Gyprock
SecurityWall
Panel 27

200mm
max.

1x 10mm
GYPROCK
plasterboard CD
1x 16mm
GYPROCK
FYRCHEK
plasterboard

600mm
max.

Cavity
Insulation
Blanket

Base Track

300mm
max.

Caulk all perimeter gaps


with Gyprock Fire Mastic

The Red Book

600mm
max.

Screw along sheet


centreline at
1200mm max. cts

B63

FIG B20: INSTALLATION DETAIL STEEL FRAME SECURITYWALL SYSTEM

For additional information, refer to GYP560, Gyprock SecurityWall Systems.

FIRE RATED
Security Wall
Track 50

Fixing Specifications for


Vertical Sheeting (shown)
Refer to Section A

1st Layer

Fixing & Spacing

Top, Bottom Screws at 600mm


& Field
max. vertical centres
x 300mm max.
horizontal centres to
all steel ribs

Gyprock
SecurityWall
Panel 50

216mm
typical.

1x 13mm
GYPROCK
FYRCHEK
plasterboard

Screws

Butt
Joints

Screws at
216mm max. centres

Corners &
Openings

Screws at
300mm max. centres

600mm
max.

Cavity
Insulation
Blanket

300mm
max.

Base Track

Caulk all perimeter gaps


with Gyprock Fire Mastic

FIG B21: INSTALLATION DETAIL STEEL FRAME SECURITYWALL SYSTEM

For additional information, refer to GYP560, Gyprock SecurityWall Systems.


Head Angle

FIRE RATED
Security Wall
Track 50

Fixing Specifications for


Vertical Sheeting (shown)

Steel Stud Profiles as


per system table at
600mm centres or
Gyprock SecurityWall
Panel 50
200mm
max.

Gyprock
SecurityWall
Panel 50
1x 10mm
GYPROCK
plasterboard CD
1x 16mm
GYPROCK
FYRCHEK
plasterboard

200mm min.
600mm
max.

300mm max.

600mm
max.

433mm
typical

Caulk all perimeter gaps


with Gyprock Fire Mastic

B64

Refer to Section A

1st Layer

Fixing & Spacing

Recessed
Edges
& Field

Screws at 600mm
max. vertical centres
to all stud profiles
OR
Screws at 600mm
max. vertical centres
x 300mm max.
horizontal centres to
all steel ribs

2nd Layer

Fixing & Spacing

Recessed
Edges

Screws at 450mm
max. cts

Field

Rows of Adhesive
Daubs at 600mm
max. horizontal cts x
300mm max. vertical
cts and 200mm min.
from fastener points
Screw along
centreline at 1300mm
max.cts

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

216mm
typical

Cavity
Insulation
Batts

Base Angles

Screws
Adhesive

300mm
max.

433mm
typical
Screw along sheet
centreline at
1200mm max. cts

The Red Book

FIG B22: INSTALLATION DETAIL FOR CINEMA WALL FOUR LAYER


HORIZONTAL SHEETING FRL 120/120/120 ONLY

For additional information, refer to GYP512, Gyprock Cinema Wall Systems.

Studs at 600mm max. cts. for 2 layers x 16mm GYPROCK Fyrchek


Studs at 900mm max. cts. for 3 layers x 16mm GYPROCK Fyrchek
Studs at 1200mm max. cts. for 4 layers x 16mm GYPROCK Fyrchek
Stud centres

400mm
max. ctrs

450mm
max. ctrs

400mm
max. ctrs

450mm
max. ctrs

Fix 1st layer


to all studs
at 400mm
max. centres

Butt Joints
in 3rd/4th
layers offset
600mm min.

Stagger joints
300mm min.

400mm
max. ctrs

Stagger joints
300mm min.

450mm
max. ctrs

Install outer layer with 10mm


max. gap around wall perimeter
and fill with Gyprock Fire Mastic

Install all covered layers in


contact with the floor

1st layer position fasteners 10


to 16mm from sheet edges

Butt joints in 3rd and 4th


layers offset from
previous layer 300mm
minimum, offset from
adjacent sheets in same
layer 600mm minimum,
and fixed with
laminating screws

FIRE RATED
Fixing Specifications
Screws

The Red Book

SUITABLE FOR:

Refer to Section A

1st Layer

Fixing & Spacing

At all studs

Screws at 400mm
max. centres

2nd, 3rd &


4th Layers

Fixing & Spacing

Recessed
Edges,
Field &
Butt Joints

Laminating screws at
450mm max.
horizontal centres
and 400mm max.
vertical centres

B65

Notes

B66

The Red Book

Section C

Timber Stud Wall Systems

Contents
Timber Stud Height Tables

C2

Introduction

C3

Design Considerations

C3 C4

Installation

C5

Components

C5

System Specifications Internal Walls


Single Stud

C6 C9

Double Stud

C10 C12

Party Wall

C13 C14

Staggered Stud

C15 C17

Resilient Mount

C18 C19

Studs Lined One Side

C20 C21

System Specifications External Walls


Cladding on Battens

C22 C23

Texture Base Sheet for Houses

C24

Hebel Powerpanel

C25

Masonry

C26 C27

Rendaline

C28 C29

Commercial ExpressWall

C30

Column & Beam

C31

System Installation Details

The Red Book

C32 C37

C1

TABLE C1: mAximum TimBER sTud hEighT


NoN-LoAdBEARiNg WALLs shEETEd WiTh gYPRoCK NoN-FiRE gRAdE PLAsTERBoARd
uNiFoRm disTRiBuTEd LoAd (udL) = 0.25kPa.
Wall Frame

Timber Grade

and Sheeting

Stud Thickness (mm)

Configuration

Stud Depth (mm)

600mm cts.

450mm
cts.

70

F5
35

F8
45

35

F11
45

35

MGP 10
45

35

45

MGP 12

MGP 15

35

45

35

45

3.5

3.9

3.8

4.1

Maximum Stud Height (m)


2.9

3.1

3.2

3.3

3.3

3.6

3.0

3.6

90

3.7

4.0

4.1

4.4

4.3

4.7

4.2

4.6

4.6

5.0

4.9

5.3

120

5.0

5.4

5.5

5.9

5.7

6.0

5.6

6.0

6.0

6.0

6.0

6.0

70

3.2

3.5

3.5

3.8

3.7

4.0

3.6

3.9

3.9

4.3

4.1

4.5

90

4.1

4.5

4.5

4.9

4.7

5.1

4.6

5.1

5.0

5.5

5.3

5.8

120

5.5

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

70

2.7

2.9

2.9

3.2

3.1

3.3

3.0

3.3

3.3

3.6

3.5

3.8

90

3.4

3.7

3.8

4.1

4.0

4.3

3.9

4.2

4.2

4.6

4.5

4.9

120

4.6

5.0

5.0

5.5

5.3

5.8

5.2

5.7

5.6

6.0

6.0

6.0

600mm cts.

600mm max. cts

300mm 300mm
cts.
cts.

TABLE C2: mAximum TimBER sTud hEighT


NoN-LoAdBEARiNg WALLs shEETEd WiTh gYPRoCK FiRE gRAdE PLAsTERBoARd
uNiFoRm disTRiBuTEd LoAd (udL) = 0.25kPa
Wall Frame

Timber Grade

and Sheeting

Stud Thickness (mm)

Configuration

Stud Depth (mm)

600mm cts.

450mm
cts.

F5
35

F8
45

35

F11
45

35

MGP 10
45

35

45

MGP 12
35

MGP 15

45

35

45

Maximum Stud Height (m)

70

3.1

3.4

3.4

3.7

3.6

3.9

3.5

3.8

3.8

4.2

4.1

4.4

90

4.0

4.4

4.4

4.8

4.6

4.8

4.5

5.0

4.9

5.4

5.2

5.7

120

5.4

5.8

5.9

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

70

3.4

3.7

3.8

4.1

3.9

4.3

3.9

4.2

4.2

4.6

4.5

4.9

90

4.4

4.8

4.9

5.3

5.1

5.5

5.0

5.5

5.4

5.9

5.8

6.0

120

5.9

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

70

2.9

3.1

3.2

3.3

3.6

3.9

3.0

3.6

3.5

3.9

3.8

4.1

90

3.7

4.0

4.1

4.4

4.3

4.7

4.2

4.6

4.6

5.0

4.9

5.3

120

5.0

5.4

5.5

5.9

5.7

6.0

5.6

6.0

6.0

6.0

6.0

6.0

600mm cts.

600mm max. cts

300mm 300mm
cts.
cts.

NOTES FOR TABLE C1 AND C2.


Stud heights have been determined based on a maximum deflection of H240 or 30mm maximum.
Noggings at 1350mm maximum centres, measured vertically. No noggings in staggered stud walls. No connection between wall frames in double
stud walls.

C2

The Red Book

Introduction
CSR Gyprock & Cemintel timber frame wall systems are
assemblies constructed from timber components with one
or more layers of Gyprock plasterboard and/or Cemintel
linings fixed to one or both sides.
A wide range of systems is available including fire rated walls,
internal and external walls, and for loadbearing applications.
Timber frame wall systems are typically used in multiresidential applications.

Design
Considerations
structural design
All walls must be designed for the applied loads. Guidance
is given for the selection of studs in non-loadbearing internal
walls only. For loadbearing walls and walls subject to wind
pressures, walls shall be designed to the appropriate
Australian Standards or construction manuals.
Non-Loadbearing Walls
Maximum wall height and the required stud size may be
selected from Table C1 or C2 appropriate for the selected
system. These walls are designed for lateral loads only, using
the composite action of the frame and sheeting.
Non-loadbearing walls in this manual have been designed
as follows for a minimum design pressure of 0.25kPa and a
maximum deflection of (height 240) or 30mm maximum.
(Based on BCA Specification C1.8, 3.4 (b)).
Wall plates must be fixed to floors and ceilings at 600mm
maximum centres. Each plate fixing is required to withstand
a shear load of 0.75kN for a UDL of 0.25kPa
Tall multi-residential buildings often have exterior operable
doors and windows, resulting in internal walls being subject
to wind pressure. In these cases, walls must be designed
for the appropriate loads.

The Red Book

Loadbearing Walls
Walls designed as loadbearing, with studs at 600mm
maximum centres and lined with GYPROCK FYRCHEK,
meet the requirements of BCA Specification C1.8 Clause
3.4 Walls generally.
The building designer must ensure loadbearing walls have
been designed:
To resist all applied loads.
To be in accordance with AS1720.1 or AS1684.
Assuming no contribution to axial strength is required of
the wall linings.
To meet the stated Fire Resistance Level (FRL), the axial load
capacity of some wall systems is reduced. This is a result
of loss of stud section from charring during a fire test. The
systems are noted with an Axial Capacity Reduction (ACR)
Group number. In these systems, the designer must increase
the applied loads to compensate for the axial capacity
reduction percentage, as shown in Table C3.
TABLE C3: AxiAL CAPACiTY REduCTioN (%) duE To
ThE EFFECT oF TimBER ChAR
Timber Size

Group 1

Group 2

Group 3

90x45

0%

0%

25%

90x35

0%

10%

30%

70x45

3%

25%

40%

70x35

8%

35%

45%

Fire Resistance
The timber frame wall systems in this manual are suitable
for the stated FRL when designed in accordance with the
structural considerations above. Wall system ratings apply
in either direction unless noted otherwise.
The fire design of timber framing is based on the principle that
a particular level of char is acceptable without compromising
the performance of the wall. CSR has carried out testing to
verify the char limit, and where it is exceeded, the allowable
axial capacity of the stud is reduced to account for the loss
of section.
To protect structural timber and steel beams and columns
within a wall, the FRL of the wall system must be at least
equivalent to that required by the structural member. For
example, a wall system with FRL 90/90/90 provides FRL
90// for a steel column within the wall.

C3

Framing & Lining


Timber stud walls required to have an FRL must comply with
the following:
Studs must be minimum 70 x 35mm and spaced at
600mm maximum centres.
Wall plates must be fixed to the fire rated support structure
with steel fasteners such as expansion anchors, easy drive
masonry anchors and power driven fasteners.

Curved walls (in plan) with a radius of curvature no less


than 3m.
The addition of any cladding.
The attachment of light weight fixtures through to the
framing.
Caulking

Fyrchek plasterboard and Cemintel fibre cement


products must be screw or nail fixed only, adhesive is not
permitted.

To attain the specified FRL, all perimeter gaps and


penetrations must be carefully and completely filled with
appropriate caulking material. CSR Gyprock Fire Mastic
or other tested fire and acoustic rated material of equivalent
or better performance must be used.

In wet areas, Gyprock Fyrchek MR should be used in


lieu of Gyprock Fyrchek.

Details for fire sealing of penetrations are shown later in this


section.

For single layer systems and first layer of multi-layer


systems, butt joints must be backed by either a stud or
nogging. Horizontal recessed joints must be backed by a
nogging or offset at least 300mm on opposite sides of the
wall.

Vermiculite plaster has no capacity to accommodate building


movement, and may not be suitable for use as a general
purpose fire rated caulking. Its use is specified in some
wall/ceiling junctions; refer to Gyprock Ceiling Systems
Installation Guide, NGYP 570.

For multi-layer vertically sheeted applications, Fyrchek


outer layer butt joints may be reinforced using laminating
screws without the need for framing support.

Acoustic Performance

Joints in the outer layer of all systems lined with


plasterboard or Wallboard must be set with Gyprock
paper tape. As a minimum, a single coat finish may be
used.
Joints in external systems lined with Cemintel Texture
Base Sheet must be set with the tape and compound
recommended for the texture coating system.
All joints in Cemintel Texture Base Sheet must be formed
on framing.
For additional information on frame design and detailing,
including treatment at junctions, sub floor and roof areas,
cavity barriers and penetrations, refer to Forest and Wood
Products publication Timber Framed Construction for MultiResidential Buildings.

The acoustic performance of wall systems is expressed in


terms of Rw and Rw+Ctr where appropriate. The performance
of the as-built system may be affected by: sound flanking,
the effectiveness of workmanship and caulking, the presence
and treatment of penetrations, and the inclusion of structural
elements and bridging items. Refer to Section A for detailed
information on addressing these issues.
general Notes
The acoustic performance of systems may be adversely
affected by the use of wider studs or closer spacings than
that specified.
In non-fire rated systems, to attain the stated acoustic
performance, use Gyprock Wet Area Acrylic Sealant,
Gyprock Fire Mastic or other tested acoustic rated
material of equivalent or better performance.

The Fire Resistance Level (FRL) of the systems detailed in


this section will not be detrimentally affected by;

The acoustic performance of CSR wall systems is not


adversely affected by:

Increasing the thickness of the wall.

the order of lining sheets that are fixed direct to framing.

Increasing the cross-sectional dimensions of the framing


elements.

the substitution of Aquachek for Gyprock Plasterboard


CD of the same thickness.

Decreasing the stud spacing.

the substitution of Gyprock Fyrchek MR for Fyrchek of


the same thickness.

Decreasing the fixing centres of wall sheet materials.


The inclusion of bulk cavity insulation materials such as
Glasswool, Rockwool and Polyester.
The use of Fyrchek MR, Impactchek, EC08 Fire or
EC08 Impact plasterboard in lieu of Fyrchek plasterboard
of the same thickness.
Additional layers of plasterboard or fibre cement.

C4

The Red Book

Installation
Framing
For detailed information on wall junctions, intersections,
frame attachments and penetrations, refer to Section Z of
this guide and Woods & Forests publication, Timber Framed
Construction for Mult-Residential Buildings.
Walls curved in plan may be built with timber stud frames.
Table for stud centres and plasterboard thickness for various
curvatures can be found in CSR Gyprock Residential
Installation, Guide NGYP547.
Gyprock Party Wall systems have additional installation
requirements. Refer to brochure NGYP513 Gyprock Party
Wall Systems.

Wallboard & Plasterboard Fixing


Interior walls may be built to achieve a particular Level of
Finish as defined in AS/NZS2589.1. The Level of Finish
specified can have requirements for frame alignment,
jointing and back blocking methods, and sheet orientation.
CeminSeal Wallboard and Gyprock plasterboard may be
installed vertically or horizontally, although for some Levels of
Finish horizontal sheeting must be used.

Walls with plasterboard outer layer: 12m maximum


centres.
External walls: Refer to the appropriate installation
manual.
At junctions with other building elements.
At junctions with different lining materials.
At change of structural support system.
At each storey or rise of studs.

External Walls
Gyprock timber frame external wall systems rely on a
range of cladding systems to provide weather resistance.
There is a range of effectiveness of these systems, and
CSR Gyprock recommends the cladding be installed with
a drained cavity. Cavity systems allow drainage and drying
of any water that penetrates, and are known to have good
long-term performance.
Sarking is also recommended to provide additional weather
protection to framing and lining.
External walls require specific design for condensation
control and energy efficiency, depending on the climate and
internal environment. Contact CSR Bradford for information
on thermal insulation systems and products.

Interior walls lined with Gyprock plasterboard or


CeminSeal Wallboard may be finished with tiles. Refer to
the relevant installation manual for details.

Components

Plasterboard Jointing & Finishing

Lining & Fixing materials

Refer to the Gyprock Residential Installation Guide,


NGYP547 and Cemintel Wet Area Lining Systems,
NFC101 for detailed jointing and finishing information.

Refer to Section A for detailed information on CSR


Gyprock and Cemintel lining products, fixings, adhesive
and accessories.

It should be noted that:


Multi-layered systems only require jointing and finishing of
the outer layer.

For details on Cemintel Texture Base Sheet, refer to manual


NFC122, Cemintel Texture Base Sheet for Applied Finish
Systems.

It is recommended that a water resistant taping compound,


such as Gyprock Wet Area Base Coat be used at vertical
wall junctions and horizontal and vertical joints within wet
areas such as showers.

For details on Cemintel RendaLine Faades, refer to CSR


guides FC945, Commercial RendaLine (using steel top
hat framing), and FC133, Residential RendaLine (using
timber battens

Control Joints

Framing

Control joints must be installed to allow for structural


movement. Allowance for movement must be made through
the frame, lining and any tiles.

Timber sizes indicated are nominal. For kiln-dried timber,


protect frames from wetting prior to and during construction
by wrapping exposed sections as soon as practicable
after erection. The timber should have a maximum of 16%
moisture content at the time of lining.

Control joints must be installed at all construction joints in


the building and at the following locations:
Non-tiled internal walls with fibre cement outer layer: 7.2m
maximum centres.
Tiled internal walls with fibre cement outer layer: 4.2m
maximum centres.

The Red Book

Accurate setting-out is required where 35mm wide framing


is used as the narrower member width is less able to
accommodate poor alignment.

C5

Timber Frame internal Wall systems single stud


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 305a shown)

PKA-051

Lining material as per system table.


Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table.
NOTES:
Acoustic performance valid for 35mm wide studs at
600mm centres.

FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

(a) Nil
Both SideS
1 x 10mm GYPROCK
Plasterboard CD.

Both SideS

//

1 x 13mm GYPROCK
Plasterboard CD.

Side one
1 x 13mm GYPROCK
Plasterboard CD.

//

Side two
1 x 13mm GYPROCK
AQUACHEK plasterboard.

CsR 315
Both SideS

//

2 x 10mm GYPROCK
Plasterboard CD.

33/26

35/28

34/25

36/27

37/28

39/30

2.0

35/25

37/27

38/28

40/30

(d) TSB3/ASB3 Polyester

32/25

34/27

34/27

36/29

90

110

140

160

(a) Nil

33/26

34/27

36/29

37/30

(b) 75 Gold Batts 1.5

37/28

38/29

40/31

41/32

(c) 75 Soundscreen 2.0

38/28

39/29

41/31

42/32

(d) TSB3/ASB3 Polyester

35/28

36/29

37/30

38/31

96

116

146

166

(a) Nil

34/27

35/28

37/30

38/31

(b) 75 Gold Batts 1.5

38/29

39/30

41/32

42/33

(c) 75 Soundscreen 2.0

39/29

40/30

42/32

43/33

(d) TSB3/ASB3 Polyester

36/29

37/30

38/31

39/32

96

116

146

166

(a) Nil

38/31

39/32

41/35

42/36

(b) 75 Gold Batts 1.5

42/33

43/34

45/37

46/38

(c) 75 Soundscreen 2.0

43/33

44/34

46/37

47/38

(d) TSB3/ASB3 Polyester

40/33

41/34

42/36

43/37

110

130

160

180

(a) Nil

40/33

42/36

43/37

44/38

(b) 75 Gold Batts 1.5

44/35

46/38

47/39

48/40

(c) 75 Soundscreen 2.0

45/35

47/38

48/39

49/40

(d) TSB3/ASB3 Polyester

42/35

44/38

44/38

45/39

122

142

172

192

(b) 75 Gold Batts 1.5


(c) 75

Soundscreen

WALL THICKNESS mm

WALL THICKNESS mm

CsR 320
Both SideS

//

2 x 13mm GYPROCK
Plasterboard CD.

WALL THICKNESS mm

CsR 322

//

C6

140

32/25

WALL THICKNESS mm

CsR 311

120

30/23

WALL THICKNESS mm

CsR 310

90

Rw / Rw+Ctr

(Refer to Section A)

CsR 305

//

70

CAViTY iNFiLL

Side one

(a) Nil

34/27

35/28

37/30

38/31

1 x 13mm GYPROCK
Plasterboard CD.

(b) 75 Gold Batts 1.5

38/29

39/30

41/32

42/33

Side two

(c) 75 Soundscreen 2.0

39/29

40/30

42/32

43/33

1 x 13mm GYPROCK
IMPACTCHEK
plasterboard.

(d) TSB3/ASB3 Polyester

36/29

37/30

38/31

39/32

96

116

146

166

WALL THICKNESS mm

The Red Book

Timber Frame internal Wall systems single stud


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 354a shown)

PKA-051

Lining material as per system table.


Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table.
NOTES:
Acoustic performance valid for 35mm wide studs at
600mm centres.

FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

(a) Nil
Both SideS
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

37/30

38/31

39/32

39/30

41/32

42/33

43/34

2.0

40/30

42/32

43/33

44/34

(d) TSB3/ASB3 Polyester

37/30

39/32

39/32

40/33

90

110

140

160

(b) 75 Gold Batts 1.5


(c) 75

Soundscreen

(a) Nil

34/27

35/28

38/30

38/31

1 x 10mm GYPROCK
AQUACHEK plasterboard.

(b) 75 Gold Batts 1.5

38/29

39/30

41/32

42/33

Side two

(c) 75 Soundscreen 2.0

39/26

40/30

42/32

43/33

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(d) TSB3/ASB3 Polyester

36/29

37/30

38/31

39/32

90

110

140

160

(a) Nil

37/30

38/31

40/34

41/35

Both SideS

(b) 75 Gold Batts 1.5

41/32

42/33

44/36

45/37

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

(c) 75 Soundscreen 2.0

42/32

43/33

45/36

46/37

(d) TSB3/ASB3 Polyester

39/32

40/33

41/35

42/36

96

116

146

166

(a) Nil

42/35

44/38

45/39

46/40

Both SideS

(b) 75 Gold Batts 1.5

46/37

48/40

49/41

50/42

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(c) 75 Soundscreen 2.0

47/37

49/40

50/41

51/42

(d) TSB3/ASB3 Polyester

44/37

46/40

46/40

47/41

110

130

160

180

(a) Nil

33/26

34/27

37/30

37/30

(b) 75 Gold Batts 1.5

37/28

38/29

41/32

41/32

(c) 75 Soundscreen 2.0

38/28

39/29

42/32

42/32

(d) TSB3/ASB3 Polyester

35/28

36/29

39/32

38/31

89

119

139

159

(a) Nil

35/28

37/30

39/32

39/32

(b) 75 Gold Batts 1.5

39/30

41/32

43/34

43/34

(c) 75 Soundscreen 2.0

40/30

42/32

44/34

44/34

(d) TSB3/ASB3 Polyester

37/30

39/32

41/34

40/33

92

112

142

162

WALL THICKNESS mm

WALL THICKNESS mm

CsR 335

//

WALL THICKNESS mm

CsR 326

Side one
1 x 13mm GYPROCK
Plasterboard CD.

//

Side two
1 x 6mm CeminSeal
Wallboard.

CsR 327

//

Side one
1 x 13mm GYPROCK
Plasterboard CD.
Side two
1 x 9mm CeminSeal
Wallboard.

The Red Book

140

Side one

CsR 354

//

120

35/28

WALL THICKNESS mm

CsR 330

90

Rw / Rw+Ctr

(Refer to Section A)

CsR 325

//

70

CAViTY iNFiLL

WALL THICKNESS mm

WALL THICKNESS mm

C7

Timber Frame internal Wall systems single stud


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 660a shown)

PKA-051

Lining material as per system table.


Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table.
NOTES:
Acoustic performance valid for 35mm wide studs at
600mm centres.

FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

(a) Nil

37/30

38/31

38/29

39/30

41/32

42/33

2.0

39/29

40/30

42/32

43/33

(d) TSB3/ASB3 Polyester

36/29

37/30

38/31

39/32

82

102

132

152

(a) Nil

41/34

43/37

45/39

45/39

(b) 75 Gold Batts 1.5

45/36

47/39

49/41

49/41

(c) 75 Soundscreen 2.0

46/36

48/39

50/41

50/41

1 x 6mm CeminSeal
Wallboard.

(d) TSB3/ASB3 Polyester

43/36

45/39

46/40

46/40

102

122

152

172

(b) 75 Gold Batts 1.5


(c) 75

Soundscreen

WALL THICKNESS mm
Both SideS (Any order)
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

CsR 352
/60/60
and
30/30/30
FAR 2303

WALL THICKNESS mm

Side one (Any order)

(a) Nil

38/31

39/32

42/35

42/36

1 x 10mm GYPROCK
Plasterboard CD.

(b) 75 Gold Batts 1.5

42/33

43/34

46/37

46/38

1 x 13mm GYPROCK
FYRCHEK plasterboard.

(c) 75 Soundscreen 2.0

43/33

44/34

47/37

47/38

Side two

(d) TSB3/ASB3 Polyester

40/33

41/34

43/36

43/37

106

126

156

176

(a) Nil

35/28

37/30

38/31

39/33

(b) 75 Gold Batts 1.5

39/30

41/32

42/33

43/35

(c) 75 Soundscreen 2.0

40/30

42/32

43/33

44/35

(d) TSB3/ASB3 Polyester

37/30

39/32

39/32

40/34

96

116

146

166

(a) Nil

34/27

36/29

39/33

39/33

(b) 75 Gold Batts 1.5

38/29

40/31

43/35

43/35

(c) 75 Soundscreen 2.0

39/29

41/31

44/35

44/35

(d) TSB3/ASB3 Polyester

36/29

39/32

40/34

40/34

102

122

152

172

(a) Nil

41/34

43/37

45/39

45/39

(b) 75 Gold Batts 1.5

45/36

47/39

49/41

49/41

(c) 75 Soundscreen 2.0

46/36

48/39

50/41

50/41

(d) TSB3/ASB3 Polyester

43/36

45/39

46/40

46/40

108

128

158

178

1 x 13mm GYPROCK
FYRCHEK plasterboard.

CsR 350
/60/60
and
30/30/30

Both SideS
1 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

WALL THICKNESS mm

WALL THICKNESS mm

CsR 355
/60/60
and
60/60/60

Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

WALL THICKNESS mm

CsR 660
/60/60
and
60/60/60
FAR 2303

Both SideS
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 13mm GYPROCK
FYRCHEK plasterboard.

WALL THICKNESS mm

C8

140

35/28

1 x 6mm CeminSeal
Wallboard.

//

120

34/27

Both SideS

CsR 653

90

Rw / Rw+Ctr

(Refer to Section A)

CsR 654

//

70

CAViTY iNFiLL

The Red Book

Timber Frame internal Wall systems single stud


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 375a shown)

PKA-051

Lining material as per system table.


Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3)
Acoustic performance valid for 35mm wide studs at
600mm centres.

FRL
Report/Opinion

sYsTEm
N

CsR 652
/90/90
and
60/60/60

Side one

Side Two
2 x 16mm GYPROCK
FYRCHEK plasterboard.

CsR 665
Both SideS
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.

* ACR Group 3
FAR 2303

/90/90
and
60/60/60
FAR 2303

(a) Nil

39/32

41/34

42/36

43/37

43/34

45/36

46/38

47/39

2.0

44/34

46/36

47/38

48/39

(d) TSB3/ASB3 Polyester

41/34

43/36

43/37

44/38

118

138

168

188

(a) Nil

43/37

44/38

45/39

46/40

(b) 75 Gold Batts 1.5

47/39

48/40

49/41

50/42

(c) 75 Soundscreen 2.0

48/39

49/40

50/41

51/42

(d) TSB3/ASB3 Polyester

45/39

46/40

46/40

47/41

114

134

164

184

(b) 75 Gold Batts 1.5


(c) 75

Soundscreen

WALL THICKNESS mm

(a) Nil

43/37

44/38

45/39

46/40

(b) 75 Gold Batts 1.5

47/39

48/40

49/41

50/42

1 x 16mm GYPROCK
FYRCHEK plasterboard.

(c) 75 Soundscreen 2.0

48/39

49/40

50/41

51/42

Side two

(d) TSB3/ASB3 Polyester

45/39

46/40

46/40

47/41

124

144

174

194

42/36

44/38

45/39

46/40

46/38

48/40

49/41

50/42

(c) 75 Soundscreen 2.0

47/38

49/40

50/41

51/42

(d) TSB3/ASB3 Polyester

44/38

46/40

46/40

47/41

122

142

172

192

42/36

44/39

45/39

45/39

46/38

48/40

49/41

49/41

2.0

47/38

49/40

50/41

50/41

(d) TSB3/ASB3 Polyester

44/38

46/40

46/40

46/40

134

154

184

204

WALL THICKNESS mm
(a) Nil

Both SideS
2 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

(b) 75 Gold

Batts

1.5

WALL THICKNESS mm

CsR 380

FAR 2303

(a) Nil
Both SideS
2 x 16mm GYPROCK
FYRCHEK plasterboard.

(b) 75 Gold Batts 1.5


(c) 75

Soundscreen

WALL THICKNESS mm

The Red Book

140

Side one (Any order)

CsR 375

/120/120
and
120/120/120

120

1 x 6mm CeminSeal
Wallboard.

2 x 16mm GYPROCK
FYRCHEK plasterboard.

/120/120
and
90/90/90

90

Rw / Rw+Ctr

WALL THICKNESS mm

CsR 667

70

CAViTY iNFiLL
(Refer to Section A)

1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

/90/90
60/60/60
90/90/90*

sTud dEPTh mm
WALL LiNiNgs

C9

Timber Frame internal Wall systems double stud


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 550a shown)

Lining material as per system table.

ACousTiC
oPiNioN
PKA-051

2 rows Timber studs at 600mm maximum centres


in each row.

Discontinuous
Construction

Cavity insulation as per system table.


20mm minimum gap between wall frames.
No connection between wall frames.
Lining material as per system table.
NOTES:
Unless otherwise specified, cavity infill is required in one stud row
only.
FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

CAViTY iNFiLL

48/42

49/43

50/44

Both SideS

(b) 75 Gold Batts 1.5

55/47

57/49

58/50

59/51

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

(c) 75 Soundscreen 2.0

56/47

58/49

59/50

60/51

(d) TSB3/ASB3 Polyester

54/48

56/50

57/51

58/52

186

226

286

326

(a) Nil

44/37

45/39

48/42

49/43

(b) 75 Gold Batts 1.5

53/44

54/46

57/49

58/50

(c) 75 Soundscreen 2.0

54/44

55/46

58/49

59/50

(d) TSB3/ASB3 Polyester

52/45

53/47

56/50

57/51

172

212

272

312

(a) Nil

48/42

49/43

50/44

51/45

(b) 75 Gold Batts 1.5

57/49

58/50

59/51

60/52

(c) 75 Soundscreen 2.0

58/49

59/50

60/51

61/52

(d) TSB3/ASB3 Polyester

56/50

57/51

58/52

59/53

178

213

278

318

(a) Nil

45/39

47/41

49/43

50/44

(b) 75 Gold Batts 1.5

54/46

56/48

58/50

59/51

(c) 75 Soundscreen 2.0

55/46

57/48

59/50

60/51

(d) TSB3/ASB3 Polyester

53/47

55/49

57/51

58/52

186

226

286

326

(a) Nil

50/44

52/46

53/47

54/48

(b) 75 Gold Batts 1.5

59/51

61/53

62/54

63/55

(c) 75 Soundscreen 2.0

60/51

62/53

63/54

64/55

(d) TSB3/ASB3 Polyester

58/52

60/54

61/55

62/56

212

252

312

352

(a) Nil

45/39

46/40

48/42

49/43

(b) 75 Gold Batts 1.5

54/46

55/47

47/49

58/50

(c) 75 Soundscreen 2.0

55/46

56/47

58/49

59/50

(d) TSB3/ASB3 Polyester

53/47

54/48

56/50

57/51

192

232

292

332

Both SideS
1 x 6mm CeminSeal
Wallboard .

WALL THICKNESS mm

CsR 675
Both SideS
1 x 9mm CeminSeal
Wallboard.

WALL THICKNESS mm

CsR 550
/60/60
and
30/30/30

Both SideS
1 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

WALL THICKNESS mm

CsR 677
Both SideS (Any order)

/60/60
and
30/30/30

1 x 13mm GYPROCK
Plasterboard CD.
1 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

WALL THICKNESS mm

CsR 555
/60/60
and
60/60/60
FAR 2303

Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.

WALL THICKNESS mm

C10

140

46/40

CsR 674

//

120

(a) Nil

WALL THICKNESS mm

//

90

Rw / Rw+Ctr

(Refer to Section A)

CsR 553

//

70

The Red Book

Timber Frame internal Wall systems double stud


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 680a shown)

Lining material as per system table.

ACousTiC
oPiNioN
PKA-051

2 rows Timber studs at 600mm maximum centres


in each row.

Discontinuous
Construction

Cavity insulation as per system table.


20mm minimum gap and no connection between wall frames.
Lining material as per system table.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3)
Unless otherwise specified, cavity infill is required in one stud row
only.
CSR 556 requires one row of batts in each stud row.
FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

CAViTY iNFiLL

Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

Both SideS

/60/60
and
60/60/60

1 x 10mm GYPROCK
Plasterboard CD.
1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

/60/60
and
60/60/60

46/40

48/42

49/43

(b) 2 x 75 Gold Batts 1.5

58/50

59/51

61/53

61/53

(c) 2 x 75 Soundscreen 2.0

59/50

60/51

62/53

62/53

(d) 2 x TSB3/ASB3 Polyester

57/51

58/52

59/53

60/54

192

232

292

332

(a) Nil

50/44

52/46

53/47

54/48

(b) 75 Gold Batts 1.5

59/51

61/53

62/54

63/55

(c) 75 Soundscreen 2.0

60/51

62/53

63/54

64/55

(d) TSB3/ASB3 Polyester

58/52

60/54

61/55

62/56

212

252

312

352

Side one

(a) Nil

48/42

50/44

51/45

52/46

1 x 16mm GYPROCK
FYRCHEK plasterboard.

(b) 75 Gold Batts 1.5

57/49

59/51

60/52

61/53

(c) 75 Soundscreen 2.0

58/49

60/51

61/52

62/53

(d) TSB3/ASB3 Polyester

56/50

58/52

59/53

60/54

198

238

298

338

(a) Nil

51/45

52/46

53/47

54/48

(b) 75 Gold Batts 1.5

60/52

61/53

62/54

63/55

(c) 75 Soundscreen 2.0

61/52

62/53

63/54

64/55

(d) TSB3/ASB3 Polyester

59/53

60/54

61/55

62/56

198

238

298

338

(a) Nil

51/45

52/46

54/48

55/49

(b) 75 Gold Batts 1.5

60/52

61/53

63/55

64/56

(c) 75 Soundscreen 2.0

61/52

62/53

64/55

65/56

(d) TSB3/ASB3 Polyester

59/53

60/54

62/56

63/57

204

244

304

344

(a) Nil

51/45

52/46

54/48

55/49

(b) 75 Gold Batts 1.5

60/52

61/53

63/55

64/56

(c) 75 Soundscreen 2.0

61/52

62/53

64/55

65/56

(d) TSB3/ASB3 Polyester

59/53

60/54

62/56

63/57

204

244

304

344

Side Two (Any order)


1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

1 x 6mm CeminSeal
Wallboard

CsR 680
Both SideS

/60/60
and
60/60/60

1 x 6mm CeminSeal
Wallboard (against studs).
1 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

WALL THICKNESS mm

WALL THICKNESS mm

CsR 681
/60/60
and
60/60/60

Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard
(against studs).
1 x 6mm CeminSeal
Wallboard.

FAR 2303

CsR 682
/90/90
60/60/60
90/90/90*
* ACR Group 3
FAR 2303

Both SideS
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.

WALL THICKNESS mm

WALL THICKNESS mm

The Red Book

140

45/39

WALL THICKNESS mm

CsR 579

120

(a) Nil

WALL THICKNESS mm

CsR 678

90

Rw / Rw+Ctr

(Refer to Section A)

CsR 556
/60/60
and
60/60/60

70

C11

Timber Frame internal Wall systems double stud


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 580a shown)

Lining material as per system table.

PKA-051

2 rows Timber studs at 600mm maximum centres


in each row.

Discontinuous
Construction

Cavity insulation as per system table.


20mm minimum gap between wall frames.
No connection between wall frames.
Lining material as per system table.
NOTES:
Unless otherwise specified, cavity infill is required in one
stud row only.
FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

CAViTY iNFiLL

Both SideS
2 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

/120/120
and
120/120/120

Both SideS
2 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

/120/120
and
120/120/120
FAR 2303

Both SideS
3 x 16mm GYPROCK
FYRCHEK plasterboard.

52/46

54/48

54/48

(b) 75 Gold Batts 1.5

60/52

61/53

63/55

63/55

(c) 75 Soundscreen 2.0

61/52

62/53

64/55

64/55

(d) TSB3/ASB3 Polyester

59/53

60/54

62/56

62/56

212

252

312

352

(a) Nil

51/45

52/46

53/47

54/48

(b) 75 Gold Batts 1.5

60/52

61/53

62/54

63/55

(c) 75 Soundscreen 2.0

61/52

62/53

63/54

64/55

(d) TSB3/ASB3 Polyester

59/53

60/54

61/55

62/56

224

264

324

364

(a) Nil

54/48

55/49

56/50

57/51

(b) 75 Gold Batts 1.5

63/55

64/56

65/57

66/58

(c) 75 Soundscreen 2.0

64/55

65/56

66/57

67/58

(d) TSB3/ASB3 Polyester

62/56

63/57

64/58

65/59

256

296

356

396

WALL THICKNESS mm

C12

140

51/45

WALL THICKNESS mm

CsR 582

120

(a) Nil

WALL THICKNESS mm

CsR 580

90

Rw / Rw+Ctr

(Refer to Section A)

CsR 575
/120/120
and
90/90/90

70

The Red Book

Timber Frame internal Wall systems Party Wall with 25mm Fire Barrier
sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 362a shown)

Lining material as per system table.

PKA-018

Timber studs at 600mm maximum centres.

Discontinuous
Construction

Cavity insulation as per system table.


20-40mm separation between frame and GYPROCK
SHAFT LINER PANEL.
25mm GYPROCK SHAFT LINER PANEL between steel HStuds at 600mm maximum centres.
20-40mm separation between frame and GYPROCK
SHAFT LINER PANEL.
Cavity insulation as per system table.
Timber studs at 600mm maximum centres.
Lining material as per system table.
NOTES: Refer to GYP513 Gyprock Party Wall System for
design considerations.
FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

CsR 360

CAViTY iNFiLL
Both sides (Refer to section A)

70

90

Rw / Rw+Ctr

(a) 75 Gold Batts 2.0

60/47

61/49

60/60/60

Both SideS

(b) 90 Gold Batts 2.7

61/48

62/50

EWFA 45743

1 x 10mm GYPROCK
SUPERCHEK.

(c) 88 Soundscreen 2.5

61/48

62/50

225

265

(a) 75 Gold Batts 2.0

61/49

62/50

WALL THICKNESS mm

CsR 361
60/60/60

Both SideS

(b) 90 Gold Batts 2.7

62/50

63/51

EWFA 45743

2 x 10mm GYPROCK
Plasterboard CD.

(c) 88 Soundscreen 2.5

62/50

63/51

245

285

(a) 75 Gold Batts 2.0

61/49

62/50

WALL THICKNESS mm

CsR 362
60/60/60

Both SideS

(b) 90 Gold Batts 2.7

62/50

63/51

EWFA 45743

1 x 13mm GYPROCK
SOUNDCHEK.

(c) 88 Soundscreen 2.5

62/50

63/51

231

271

(a) 75 Gold Batts 2.0

62/50

63/51

WALL THICKNESS mm

CsR 363
Both SideS (Any order)

60/60/60

1 x 6mm CeminSeal
Wallboard.

(b) 90 Gold Batts 2.0

62/50

63/51

EWFA 45743

1 x 10mm GYPROCK
AQUACHEK plasterboard.

(c) 88 Soundscreen 2.5

63/51

64/52

237

277

WALL THICKNESS mm

CsR 364
60/60/60
EWFA 45743

The Red Book

Both SideS (Any order)

(a) 75 Gold Batts 1.5

61/49

62/50

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(b) 90 Gold Batts 2.0

62/50

63/51

(c) 88 Soundscreen 2.5

63/51

64/52

245

285

1 x 10mm GYPROCK
plasterboard CD.

WALL THICKNESS mm

C13

Timber Frame internal Wall systems Party Wall with 41mm Fire Barrier
sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 370a shown)

Lining material as per system table.

PKA-018

Timber studs at 600mm maximum centres.

Discontinuous
Construction

Cavity insulation as per system table.


20-40mm separation between frame and GYPROCK
SHAFT LINER PANEL.
25mm GYPROCK SHAFT LINER PANEL between steel Hstuds at 600mm maximum centres.
16mm GYPROCK FYRCHEK screw laminated to SHAFT
LINER
20-40mm separation between frame and GYPROCK
FYRCHEK.
Cavity insulation as per system table.
Timber studs at 600mm maximum centres.
Lining material as per system table.
NOTES: Refer to GYP513 Gyprock Party Wall System for
design considerations.
FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

CAViTY iNFiLL
Both sides (Refer to Section A)

CsR 368

70

90

Rw / Rw+Ctr

(a) 75 Gold Batts 1.5

63/51

64/52

90/90/90

Both SideS

(b) 90 Gold Batts 2.0

64/52

65/53

EWFA 45743

1 x 10mm GYPROCK
SUPERCHEK

(c) 60 Soundscreen 1.6

63/50

64/51

241

281

(a) 75 Gold Batts 1.5

64/52

65/53

WALL THICKNESS mm

CsR 369
90/90/90

Both SideS

(b) 90 Gold Batts 2.0

65/53

66/54

EWFA 45743

2 x 10mm GYPROCK
Plasterboard CD

(c) 60 Soundscreen 1.6

64/51

65/52

261

301

(a) 75 Gold Batts 1.5

64/52

65/53

WALL THICKNESS mm

CsR 370
90/90/90

Both SideS

(b) 90 Gold Batts 2.0

65/53

66/54

EWFA 45743

1 x 13mm GYPROCK
SOUNDCHEK

(c) 60 Soundscreen 1.6

64/51

65/52

247

287

(a) 75 Gold Batts 1.5

63/50

64/52

WALL THICKNESS mm

CsR 371
90/90/90

Both SideS

(b) 90 Gold Batts 2.0

64/51

65/53

EWFA 45743

1 x 6mm CeminSeal
Wallboard

(c) 75 Soundscreen 2.0

64/50

65/52

233

273

(a) 75 Gold Batts 1.5

63/51

64/52

WALL THICKNESS mm

CsR 372
90/90/90

Both SideS

(b) 90 Gold Batts 2.0

64/52

65/53

EWFA 45743

1 x 13mm GYPROCK
AQUACHEK Plasterboard

(c) 60 Soundscreen 1.6

63/50

64/51

247

287

WALL THICKNESS mm

C14

The Red Book

Timber Frame internal Wall systems staggered stud


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 425a shown)

ACousTiC
oPiNioN
PKA-051

Lining material as per system table.


Staggered timber studs at 600mm maximum centres each
side.

NOT
Deemed
Discontinuous
Construction

Minimum 20mm clearance between stud and opposing


lining.
No noggings or any connection between studs.
Cavity insulation as per system table. (Insulation may need
to be cut and placed between studs).
Lining material as per system table.

FRL
Report/Opinion

sYsTEm
N

WALL LiNiNgs

CsR 425

(a) Nil
Both SideS
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

PLATE WidTh mm

Both SideS

//

1 x 13mm GYPROCK
Plasterboard CD.

Side one
1 x 10mm GYPROCK
Plasterboard CD.

//

Side two
1 x 6mm CeminSeal
Wallboard.

CsR 662

//

Side one
1 x 10mm GYPROCK
SUPERCHEK.
Side two
1 x 6mm CeminSeal
Wallboard.

The Red Book

140

43/36

44/37

50/41

52/43

53/44

2.0

51/41

53/43

54/44

(d) TSB3/ASB3 Polyester

48/41

49/42

50/43

110

140

160

(a) Nil

40/33

41/34

43/36

(b) 75 Gold Batts 1.5

49/40

50/41

52/43

(c) 75 Soundscreen 2.0

50/40

51/41

53/43

(d) TSB3/ASB3 Polyester

47/40

47/40

49/42

116

146

166

(a) Nil

38/31

40/33

41/34

(b) 75 Gold Batts 1.5

47/38

49/40

50/41

(c) 75 Soundscreen 2.0

48/38

50/40

51/41

(d) TSB3/ASB3 Polyester

45/38

46/39

47/40

106

136

156

(a) Nil

41/34

43/36

44/37

(b) 75 Gold Batts 1.5

50/41

52/43

53/44

(c) 75 Soundscreen 2.0

51/41

53/43

54/44

(d) TSB3/ASB3 Polyester

48/41

49/42

50/43

106

136

156

(b) 75 Gold Batts 1.5


(c) 75

Soundscreen

WALL THICKNESS mm

CsR 661

120
Rw / Rw+Ctr

41/34

WALL THICKNESS mm

CsR 422

90

CAViTY iNFiLL (Refer to Section A)

WALL THICKNESS mm

WALL THICKNESS mm

C15

Timber Frame internal Wall systems staggered stud


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 666a shown)

PKA-051

Lining material as per system table.


Staggered timber studs at 600mm maximum centres each
side.

NOT
Deemed
Discontinuous
Construction

Minimum 20mm clearance between stud and opposing


lining.
No noggings or any connection between studs.
Cavity insulation as per system table. (Insulation may need
to be cut and placed between studs).
Lining material as per system table.

FRL
Report/Opinion

sYsTEm
N

PLATE WidTh mm
WALL LiNiNgs

CAViTY iNFiLL
40/33

42/35

43/36

(b) 75 Gold Batts 1.5

49/40

51/42

52/43

(c) 75 Soundscreen 2.0

50/40

52/42

53/43

(d) TSB3/ASB3 Polyester

47/40

48/41

49/42

102

132

152

(a) Nil

44/37

45/39

47/41

(b) 75 Gold Batts 1.5

53/44

54/46

56/48

(c) 75 Soundscreen 2.0

54/44

55/46

57/48

(d) TSB3/ASB3 Polyester

51/44

51/45

53/47

108

138

158

(a) Nil

40/33

41/34

43/36

(b) 75 Gold Batts 1.5

49/40

50/41

52/43

(c) 75 Soundscreen 2.0

50/40

51/41

53/43

(d) TSB3/ASB3 Polyester

47/40

47/40

49/42

109

139

159

(a) Nil

49/43

50/44

51/45

Both SideS

(b) 75 Gold Batts 1.5

58/50

59/51

60/52

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(c) 75 Soundscreen 2.0

59/50

60/51

61/52

(d) TSB3/ASB3 Polyester

56/50

56/50

57/51

130

160

180

(a) Nil

41/34

44/37

44/38

(b) 75 Gold Batts 1.5

50/41

53/44

53/45

(c) 75 Soundscreen 2.0

51/41

54/44

54/45

(d) TSB3/ASB3 Polyester

48/41

50/43

50/44

116

146

166

(a) Nil

42/35

43/37

44/38

(b) 75 Gold Batts 1.5

51/42

52/44

53/45

(c) 75 Soundscreen 2.0

52/42

53/44

54/45

(d) TSB3/ASB3 Polyester

49/42

49/43

50/44

122

152

172

1 x 6mm CeminSeal
Wallboard.

WALL THICKNESS mm

CsR 664
Both SideS
1 x 9mm CeminSeal
Wallboard.

WALL THICKNESS mm

CsR 666

Side one
1 x 13mm GYPROCK
Plasterboard CD.

//

Side two
1 x 6mm CeminSeal
Wallboard.

CsR 430

//

WALL THICKNESS mm

WALL THICKNESS mm

CsR 450
/60/60
and
30/30/30

Both SideS
1 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

WALL THICKNESS mm

CsR 455
/60/60
and
60/60/60
FAR 2303

Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.

WALL THICKNESS mm

C16

140

(a) Nil
Both SideS

//

120
Rw / Rw+Ctr

(Refer to Section A)

CsR 663

//

90

The Red Book

Timber Frame internal Wall systems staggered stud


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 670a shown)

PKA-051

Lining material as per system table.


Staggered timber studs at 600mm maximum centres each side.

NOT
Deemed
Discontinuous
Construction

Minimum 20mm clearance between stud and opposing lining.


No noggings or any connection between studs.
Cavity insulation as per system table. (Insulation may need to be
cut and placed between studs).
Lining material as per system table.
NOTES: *ACR = Axial Capacity Reduction. (Refer to Table C3).

FRL
Report/Opinion

sYsTEm
N

PLATE WidTh mm
WALL LiNiNgs

Both SideS
1 x 6mm CeminSeal
Wallboard.(against studs).
1 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

CAViTY iNFiLL

/60/60
and
60/60/60

Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard
(against studs).
1 x 6mm CeminSeal
Wallboard.

FAR 2303

CsR 672
/90/90
and
90/90/90*

Both SideS
1 x 6mm CeminSeal
Wallboard (against studs).

* ACR Group 3

1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

48/42

49/43

50/44

(b) 75 Gold Batts 1.5

57/49

58/50

59/51

(c) 75 Soundscreen 2.0

58/49

59/50

60/51

(d) TSB3/ASB3 Polyester

55/49

55/49

56/50

128

158

178

(a) Nil

49/43

50/44

51/45

(b) 75 Gold Batts 1.5

58/50

59/51

60/52

(c) 75 Soundscreen 2.0

59/50

60/51

61/52

(d) TSB3/ASB3 Polyester

59/50

56/50

57/51

134

164

184

(a) Nil

49/43

50/44

51/45

(b) 75 Gold Batts 1.5

58/50

59/51

60/52

(c) 75 Soundscreen 2.0

59/50

60/51

61/52

(d) TSB3/ASB3 Polyester

59/50

56/50

57/51

134

164

184

(a) Nil

49/43

50/44

51/45

(b) 75 Gold Batts 1.5

58/50

59/51

60/52

(c) 75 Soundscreen 2.0

59/50

60/51

61/52

(d) TSB3/ASB3 Polyester

56/50

56/50

57/51

142

172

192

(a) Nil

48/42

49/43

50/44

(b) 75 Gold Batts 1.5

57/49

58/50

59/51

(c) 75 Soundscreen 2.0

58/49

59/50

60/51

(d) TSB3/ASB3 Polyester

55/49

55/49

56/50

154

184

204

WALL THICKNESS mm

WALL THICKNESS mm

CsR 475
/120/120
and
90/90/90

Both SideS
2 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

WALL THICKNESS mm

CsR 480
/120/120
and
120 /120/120
FAR 2303

Both SideS
2 x 16mm GYPROCK
FYRCHEK plasterboard.

WALL THICKNESS mm

The Red Book

140

(a) Nil

WALL THICKNESS mm

CsR 671

120
Rw / Rw+Ctr

(Refer to Section A)

CsR 670
/60/60
and
60/60/60

90

C17

Timber Frame internal Wall systems Resilient mount


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 403a shown)

PKA-051
NOT
Deemed
Discontinuous
Construction

Lining material as per system table.


Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Gyprock Resilient Mounts and RONDO N308 or 129
Furring Channel clipped to resilient mounts.
Lining material as per system table.

FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

CAViTY iNFiLL

44/38

45/39

46/40

Both SideS

(b) 75 Gold Batts 1.5

50/41

52/44

53/45

53/45

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

(c) 75 Soundscreen 2.0

51/41

53/44

54/45

54/45

(d) TSB3/ASB3 Polyester

48/41

50/44

50/44

51/45

124

144

174

194

42/35

43/36

45/38

45/39

50/41

51/42

53/44

52/44

2.0

51/41

52/42

54/44

53/44

(d) TSB3/ASB3 Polyester

48/41

49/42

50/43

50/44

117

137

167

187

Side one (Mount Side)

Side two
1 x 6mm CeminSeal
Wallboard.

CsR 403

//

47/40

48/42

48/42

(b) 75 Gold Batts 1.5

53/44

55/46

56/48

55/47

(c) 75 Soundscreen 2.0

54/44

56/46

57/48

56/47

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(d) TSB3/ASB3 Polyester

51/44

53/46

53/47

53/47

128

148

178

198

Side one (Mount Side)

(a) Nil

44/37

45/38

47/40

47/40

(b) 75 Gold Batts 1.5

52/43

53/44

55/46

54/45

(c) 75 Soundscreen 2.0

53/43

54/44

56/46

55/45

(d) TSB3/ASB3 Polyester

50/43

51/44

52/45

52/45

128

148

178

198

44/37

46/39

47/40

48/42

52/43

54/45

55/46

55/47

(c) 75 Soundscreen 2.0

53/43

55/45

56/46

56/47

(d) TSB3/ASB3 Polyester

50/43

52/45

52/45

53/47

124

144

174

194

Side one (Mount Side)


2 x 10mm GYPROCK
SUPERCHEK
plasterboard.
Side two
1 x 6mm CeminSeal
Wallboard.

C18

MIN. WALL THICKNESS mm

45/38

1 x 10mm GYPROCK
AQUACHEK plasterboard.

//

(c) 75

Soundscreen

(a) Nil

Side two

CsR 411

(b) 75 Gold Batts 1.5

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

(a) Nil

Side One (Mount Side)

Side Two

CsR 410

140

42/35

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

120

(a) Nil

MIN. WALL THICKNESS mm

CsR 407

90

Rw / Rw+Ctr

(Refer to Section A)

CsR 406

//

70

MIN. WALL THICKNESS mm

MIN. WALL THICKNESS mm


(a) Nil
(b) 75 Gold

Batts

1.5

MIN. WALL THICKNESS mm

The Red Book

Timber Frame internal Wall systems Resilient mount


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 414a shown)

PKA-051
NOT
Deemed
Discontinuous
Construction

Lining material as per system table.


Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Gyprock Resilient Mounts and RONDO N308 or 129
Furring Channel clipped to resilient mounts.
Lining material as per system table.

FRL
Report/Opinion

sYsTEm
N

sTud dEPTh mm
WALL LiNiNgs

CAViTY iNFiLL

Both SideS
1 x 16mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

/120/120
and
90/90/90

2 x 13mm GYPROCK
FYRCHEK plasterboard.

FAR 2303

43/37

44/38

44/38

(b) 75 Gold Batts 1.5

49/40

51/43

52/44

51/43

(c) 75 Soundscreen 2.0

50/40

52/43

53/44

52/43

(d) TSB3/ASB3 Polyester

47/40

49/43

49/43

49/43

130

150

180

200

48/42

49/43

50/44

51/45

56/48

57/49

58/50

58/50

2.0

57/48

58/49

59/50

59/50

(d) TSB3/ASB3 Polyester

54/48

55/49

55/49

56/50

150

170

200

220

(a) Nil

48/42

49/43

50/44

50/44

(b) 75 Gold Batts 1.5

56/48

57/49

58/50

57/49

(c) 75 Soundscreen 2.0

57/48

58/49

59/50

58/49

(d) TSB3/ASB3 Polyester

54/48

55/49

55/49

55/49

162

182

212

232

(b) 75 Gold Batts 1.5


(c) 75

Soundscreen

MIN. WALL THICKNESS mm

CsR 419
/120/120
and
120/120/120
FAR 2303

Both SideS
2 x 16mm GYPROCK
FYRCHEK plasterboard.

MIN. WALL THICKNESS mm

The Red Book

140

41/34

(a) Nil
Both SideS

120

(a) Nil

MIN. WALL THICKNESS mm

CsR 415

90

Rw / Rw+Ctr

(Refer to Section A)

CsR 414
/60/60
and
60/60/60

70

C19

Timber Frame internal Wall systems Lined one side


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 388a shown)

ACousTiC
oPiNioN
PKA-051

Timber studs at 600mm maximum centres.


Cavity insulation as per system table.
Lining material as per system table.

FRL
Report/Opinion

sYsTEm
N

WALL LiNiNgs

sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)

70
Rw / Rw+Ctr

CsR 386
one Side only
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

(a) Nil

26/24

WALL THICKNESS mm

80

CsR 387
one Side only

//

(a) Nil

26/24

1 x 13mm GYPROCK
Plasterboard CD.
WALL THICKNESS mm

83

CsR 388
one Side only
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

(a) Nil

30/28

WALL THICKNESS mm

83

CsR 389
one Side only

//

(a) Nil

29/27

1 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm

C20

86

The Red Book

Timber Frame internal Wall systems Lined one side


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 393a shown)

ACousTiC
oPiNioN
PKA-051

Timber studs at 600mm maximum centres.


Cavity insulation as per system table.
Lining material as per system table.

FRL
Report/Opinion

/30/30
and
30/30/30

sYsTEm
N

one Side only

Fire rated from


lined side only
FAR 2303

The Red Book

(a) Nil

Rw / Rw+Ctr

35/32

WALL THICKNESS mm

96

CsR 391
one Side only

(a) Nil

35/32

2 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm

102

CsR 392
one Side only

(a) Nil

38/35

3 x 13mm GYPROCK
FYRCHEK plasterboard.

Fire rated from


lined side only
FAR 2303

/120/120
and
120/120/120

CAViTY iNFiLL (Refer to Section A)

70

2 x 13mm GYPROCK
FYRCHEK plasterboard.

Fire rated from


lined side only
FAR 2303

/90/90
and
90/90/90

sTud dEPTh mm

CsR 390

Fire rated from


lined side only
FAR 2303

/60/60
and
60/60/60

WALL LiNiNgs

WALL THICKNESS mm

109

CsR 393
one Side only

(a) Nil

38/35

3 x 16mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm

118

C21

Timber Frame External Wall systems Cladding on Battens


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 900a shown)

External cladding material on battens.

PKA-055

Sarking.
Lining material as per system table to external side.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at
600mm centres.
FRL
Report/Opinion

sYsTEm
N

CsR 906

WALL LiNiNgs

from outside only

Rt(sum)

(a) Nil

35

1.0

0.9

(b) 75 Gold Batts 1.5

38

2.4

2.2

(c) 75 Soundscreen 2.0

39

2.9

2.7

TYPICAL WALL THICKNESS mm

154

externAl wAll Side

(a) Nil

36

1.0

1.0

1 x 16mm GYPROCK
FYRCHEK MR plasterboard.

(b) 75 Gold Batts 1.5

39

2.4

2.2

(c) 75 Soundscreen 2.0

40

3.0

2.7

TYPICAL WALL THICKNESS mm

157

externAl wAll Side

(a) Nil

38

1.1

1.0

1 x 16mm GYPROCK
FYRCHEK MR plasterboard.

(b) 75 Gold Batts 1.5

41

2.5

2.3

(c) 75 Soundscreen 2.0

42

3.0

2.8

TYPICAL WALL THICKNESS mm

163

externAl wAll Side

(a) Nil

38

1.1

1.0

2 x 13mm GYPROCK
FYRCHEK MR plasterboard.

(b) 75 Gold Batts 1.5

41

2.4

2.2

(c) 75 Soundscreen 2.0

42

2.9

2.7

TYPICAL WALL THICKNESS mm

167

(a) Nil

40

1.1

1.1

(b) 75 Gold Batts 1.5

43

2.4

2.2

(c) 75 Soundscreen 2.0

44

3.0

2.7

TYPICAL WALL THICKNESS mm

173

(a) Nil

44

1.3

1.2

(b) 75 Gold Batts 1.5

47

2.6

2.4

(c) 75 Soundscreen 2.0

48

3.1

2.8

TYPICAL WALL THICKNESS mm

195

externAl wAll Side

1 x 6mm CSR CeminSeal


Wallboard.

CsR 900
60/60/60*
from outside only
* ACR Group 2

internAl wAll Side


1 x 10mm GYPROCK
Plasterboard CD.

FAR 2303

CsR 901
60/60/60

internAl wAll Side

FAR 2303

1 x 16mm GYPROCK
FYRCHEK plasterboard.

CsR 907
90/90/90
from outside only

internAl wAll Side

FAR 2303

1 x 10mm GYPROCK
Plasterboard CD.

CsR 908

internAl wAll Side

FAR 2303

1 x 10mm GYPROCK
Plasterboard CD.

CsR 909
120/120/120
FAR 2303

externAl wAll Side


2 x 16mm GYPROCK
FYRCHEK MR plasterboard.

120/120/120
from outside only

externAl wAll Side


2 x 16mm GYPROCK
FYRCHEK MR plasterboard.
internAl wAll Side
2 x 16mm GYPROCK
FYRCHEK plasterboard.

C22

ThERmAL
Rt(win)

internAl wAll Side

FAR 2303

90
Rw

1 x 16mm GYPROCK
FYRCHEK MR plasterboard.

30/30/30

sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)

The Red Book

Timber Frame External Wall systems Cladding on Battens


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 911a shown)

ACousTiC
oPiNioN

External cladding material on battens.


PKA-055

Sarking.
Lining material as per system table to external side.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at
600mm centres.
FRL
Report/Opinion

sYsTEm
N

WALL LiNiNgs
externAl wAll Side

60/60/60
and
(90/90/90*

CsR 911

1 x 6mm
CSR CeminSeal
Wallboard (against studs)
1 x 16mm GYPROCK
FYRCHEK MR
plasterboard.

from outside only)


* ACR Group 3

1 x 16mm GYPROCK
FYRCHEK plasterboard.
externAl wAll Side

CsR 912

* ACR Group 3
FAR 2303

90

ThERmAL

Rw

Rt(win)

Rt(sum)

(a) Nil

40

1.1

1.0

43

2.5

2.3

44

3.0

2.8

(b) 75 Gold Batts 1.5

(c) 75 Soundscreen 2.0

internAl wAll Side

FAR 2303

90/90/90*

sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)

1 x 6mm
CSR CeminSeal
Wallboard (against studs)
1 x 16mm GYPROCK
FYRCHEK MR
plasterboard.

TYPICAL WALL THICKNESS mm

169

(a) Nil

44

1.2

1.1

48

2.5

2.3

49

3.0

2.8

(b) 75 Gold Batts 1.5

(c) 75 Soundscreen 2.0

internAl wAll Side


2 x 13mm GYPROCK
FYRCHEK plasterboard.

The Red Book

TYPICAL WALL THICKNESS mm

179

C23

Timber Frame External Wall systems Texture Base sheet for houses
sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 915a shown)

External cladding of 1 x 7.5mm CSR Cemintel Texture Base Sheet.


PKA-051

Sarking.
Lining material as per system table to external side.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at 600mm
centres.
FRL
Report/Opinion

sYsTEm
N

CsR 902
60/60/60*
from outside only

60/60/60*
* ACR Group 1
FAR 2303

60/60/60
and
90/90/90*
* ACR Group 3
FAR 2303

C24

0.5

1 x 13mm GYPROCK
FYRCHEK MR plasterboard.

(b) 90 Gold Batts 2.7

46/37

3.2

2.9

(c) 75 Soundscreen 2.0

45/35

2.4

2.2

120

(a) Nil

40/33

0.5

0.5

1 x 13mm GYPROCK
FYRCHEK MR plasterboard.

(b) 90 Gold Batts 2.7

46/37

3.2

2.9

(c) 75 Soundscreen 2.0

45/35

2.5

2.3

WALL THICKNESS mm

126

externAl wAll Side

(a) Nil

45/39

0.6

0.6

1 x 16mm GYPROCK
FYRCHEK MR plasterboard.

(b) 90 Gold Batts 2.7

51/43

3.3

3.0

(c) 75 Soundscreen 2.0

50/41

2.5

2.3

2 x 13mm GYPROCK
FYRCHEK plasterboard.

CsR 916

WALL THICKNESS mm

externAl wAll Side

internAl wAll Side

FAR 2303

Rt(sum)

0.5

1 x 16mm GYPROCK
FYRCHEK plasterboard.

* ACR Group 3

ThERmAL
Rt(win)

40/33

internAl wAll Side

CsR 915

90
Rw / Rw+Ctr

(a) Nil

1 x 10mm GYPROCK
Plasterboard CD.

CsR 903

sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)

externAl wAll Side

internAl wAll Side

* ACR Group 1
FAR 2303

60/60/60
and
90/90/90*

WALL LiNiNgs

externAl wAll Side


1 x 16mm GYPROCK
FYRCHEK MR plasterboard.
internAl wAll Side
1 x 6mm CSR CeminSeal
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.

WALL THICKNESS mm

139

(a) Nil

45/39

0.6

0.6

(b) 90 Gold Batts 2.7

51/43

3.2

3.0

(c) 75 Soundscreen 2.0

50/41

2.5

2.3

WALL THICKNESS mm

135

The Red Book

Timber Frame External Wall systems hebel Powerpanel


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (hEBEL 1400)

2010675.1/
2401A/R1/Jh

CSR Hebel Powerpanel AAC (75mm) screw fixed to


22mm battens installed at 1200mm maximum vertical
centres.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
Refer to CSR Hebel for design considerations and panel
installation details.

FRL
Report/Opinion

sYsTEm
N

WALL LiNiNgs

hEBEL 1400
240/180/180
from outside only
FSV 0536

sTud dEPTh mm

90

Rw / Rw+Ctr

(a) Nil

46/40

(b) 90 Gold Batts 2.0

ThERmAL
Rt(win)

Rt(sum)

46/40

0.9

0.9

53/44

53/45

2.8

2.6

177

197

internAl wAll Side


1 x 10mm GYPROCK
Plasterboard CD.

TYPICAL WALL THICKNESS mm

The Red Book

70

CAViTY iNFiLL (Refer to Section A)

C25

Timber Frame External Wall systems masonry


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 920a shown)

Fire rated masonry veneer wall.

PKA-055

Timber studs at 600mm maximum centres with 40mm


minimum gap to masonry.
Cavity insulation as per system table.
Lining material as per system table.
NOTES:
To achieve stated acoustic performance masonry must be
a minimum of 90mm thick and 170kg/m2.
*ACR = Axial Capacity Reduction. (Refer to Table C3).
FRL
Report/Opinion

sYsTEm
N

CsR 923
60/60/60
from outside only

WALL LiNiNgs

60/60/60
from outside only

CsR 925
60/60/60
from outside only

CsR 920
60/60/60
FAR 2303

60/60/60*

Masonry veneer wall with


FRL 60/60/60.

(b) 75 Gold Batts 1.5

59/50

2.1

2.0

(c) 88 Soundscreen 2.5

60/51

3.2

2.9

* ACR Group 1
FAR 2303
Refer to masonry
manufacturer

C26

WALL THICKNESS mm

250

externAl Side

(a) Nil

53/46

0.5

0.5

Masonry veneer wall with


FRL 60/60/60.

(b) 75 Gold Batts 1.5

60/53

2.1

2.0

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(c) 88 Soundscreen 2.5

61/54

3.2

2.9

externAl Side

(a) Nil

56/49

0.6

0.6

Masonry veneer wall with


FRL 60/60/60.

(b) 75 Gold Batts 1.5

63/56

2.2

2.0

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

(c) 88 Soundscreen 2.5

64/57

3.2

3.0

externAl Side

(a) Nil

54/46

0.6

0.6

Masonry veneer wall with


FRL 60/60/60.

(b) 75 Gold Batts 1.5

61/53

2.2

2.0

(c) 88 Soundscreen 2.5

62/54

3.2

2.9

1 x 16mm GYPROCK
FYRCHEK plasterboard.

CsR 927

Rt(sum)
0.5

internAl Side

Refer to masonry
manufacturer

Rt(win)
0.5

internAl Side
Refer to masonry
manufacturer

Rw / Rw+Ctr
52/44

internAl Side
Refer to masonry
manufacturer

ThERmAL

(a) Nil

1 x 10mm GYPROCK
Plasterboard CD.

CsR 924

CAViTY iNFiLL (Refer to Section A)

90

externAl Side

internAl Side

Refer to masonry
manufacturer

sTud dEPTh mm

externAl Side
Masonry veneer wall with
FRL 60/60/60.
internAl Side
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 13mm GYPROCK
FYRCHEK plasterboard.

WALL THICKNESS mm

WALL THICKNESS mm

WALL THICKNESS mm

250

260

256

(a) Nil

54/46

0.6

0.6

(b) 75 Gold Batts 1.5

61/53

2.2

2.0

(c) 88 Soundscreen 2.5

62/54

3.2

2.9

WALL THICKNESS mm

259

The Red Book

Timber Frame External Wall systems masonry


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 921a shown)

Fire rated masonry veneer wall.

ACousTiC
oPiNioN
PKA-055

Timber studs at 600mm maximum centres with 40mm


minimum gap to masonry.
Cavity insulation as per system table.
Lining material as per system table.
NOTES:
To achieve stated acoustic performance masonry must be
a minimum of 90mm thick and 170kg/m2.
*ACR = Axial Capacity Reduction. (Refer to Table C3).
FRL
Report/Opinion

sYsTEm
N

CsR 921
90/90/90

internAl Side

Refer to masonry
manufacturer

* ACR Group 3
FAR 2303
Refer to masonry
manufacturer

The Red Book

externAl Side
Masonry veneer wall with
FRL 90/90/90.

FAR 2303

90/90/90*

WALL LiNiNgs

2 x 13mm GYPROCK
FYRCHEK plasterboard.

CsR 928

externAl Side
Masonry veneer wall with
FRL 90/90/90.
internAl Side
1 x 6mm CeminSeal
Wallboard (against studs).
1 x 16mm GYPROCK
FYRCHEK plasterboard.

sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)

90

ThERmAL

Rw / Rw+Ctr

Rt(win)

Rt(sum)

(a) Nil

56/49

0.6

0.6

(b) 75 Gold Batts 1.5

63/56

2.2

2.0

(c) 88 Soundscreen 2.5

64/57

3.3

3.0

WALL THICKNESS mm

266

(a) Nil

56/49

0.6

0.6

(b) 75 Gold Batts 1.5

63/56

2.2

2.0

(c) 88 Soundscreen 2.5

64/57

3.2

3.0

WALL THICKNESS mm

262

C27

Timber Frame External Wall systems RendaLine


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 690a shown)

1 x Cemintel RendaLine sheet on timber battens.

ACousTiC
oPiNioN
PKA-051

Sarking.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
Acoustic performance valid for 35mm wide studs at 600mm
centres.
FRL
Report/Opinion

sTud dEPTh mm

90

CAViTY iNFiLL (Refer to Section A)

Rw

Rt(win)

Rt(sum)

(a) Nil

39

1.7

1.5

internAl Side

(b) 75 Gold Batts 1.5

45

2.5

2.3

1 x 10mm GYPROCK
Plasterboard CD.

(c) 88 Soundscreen 2.5

45

3.6

3.3

sYsTEm
N

WALL LiNiNgs

CsR 690

//

WALL THICKNESS mm

sYsTEm sPECiFiCATioN

ThERmAL

143

TYPiCAL LAYouT (CsR 693a shown)

ACousTiC
oPiNioN

1 x Cemintel RendaLine sheet on timber battens.


PKA-055

Sarking.
1 x 13mm GYPROCK FYRCHEK MR plasterboard.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at 600mm
centres.
FRL
Report/Opinion

sYsTEm
N

CsR 693
60/60/60

sTud dEPTh mm

90

CAViTY iNFiLL (Refer to Section A)

Rw

Rt(win)

Rt(sum)

externAl Side

(a) Nil

45

1.2

1.1

As per system
specification.

(b) 75 Gold Batts 1.5

51

2.6

2.4

(c) 88 Soundscreen 2.5

53

3.7

3.4

WALL LiNiNgs

internAl Side

FAR 2303

1 x 16mm GYPROCK
FYRCHEK plasterboard.

CsR 696
60/60/60*
From outside only
* ACR Group 2
FAR 2303

C28

WALL THICKNESS mm

ThERmAL

162

externAl Side

(a) Nil

43

1.2

1.1

As per system
specification.

(b) 75 Gold Batts 1.5

49

2.6

2.4

(c) 88 Soundscreen 2.5

51

3.7

3.3

internAl Side
1 x 10mm GYPROCK
Plasterboard CD.

WALL THICKNESS mm

156

The Red Book

Timber Frame External Wall systems RendaLine


sYsTEm sPECiFiCATioN

TYPiCAL LAYouT (CsR 694a shown)

1 x Cemintel RendaLine sheet on timber battens.

ACousTiC
oPiNioN
PKA-051

25mm Bradford Fibertex 450 Rockwool (80kg/m3) between battens.


Wire mesh and sarking.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at 600mm centres.
FRL
Report/Opinion

sTud dEPTh mm

90

CAViTY iNFiLL (Refer to Section A)

Rw

Rt(win)

Rt(sum)

externAl Side

(a) Nil

48

1.8

1.6

As per system
specification.

(b) 75 Gold Batts 1.5

50

2.6

2.4

(c) 88 Soundscreen 2.5

50

3.6

3.3

sYsTEm
N

CsR 694

60/60/60

WALL LiNiNgs

internAl Side

FAR 2303

1 x 16mm GYPROCK
FYRCHEK plasterboard.

CsR 697
60/60/60
From outside only

149

externAl Side

(a) Nil

45

1.8

1.5

As per system
specification.

(b) 75 Gold Batts 1.5

47

2.6

2.3

(c) 88 Soundscreen 2.5

47

3.6

3.3

internAl Side

FAR 2303

WALL THICKNESS mm

ThERmAL

1 x 10mm GYPROCK
Plasterboard CD.

WALL THICKNESS mm

sYsTEm sPECiFiCATioN

143

TYPiCAL LAYouT (CsR 695a shown)

1 x Cemintel RendaLine sheet on timber battens.

ACousTiC
oPiNioN
PKA-055

25mm Bradford Fibertex 450 Rockwool (80kg/m3) between battens


1 x 6mm CeminSeal Wallboard.
Timber studs at 600mm maximum centres.
Cavity insulation as per system table.
Lining material as per system table to internal side.
NOTES:
*ACR = Axial Capacity Reduction. (Refer to Table C3).
Acoustic performance valid for 35mm wide studs at 600mm centres.
FRL
Report/Opinion

sYsTEm
N

CsR 695

internAl Side

* ACR Group 3

1 x 6mm CeminSeal
Wallboard (against studs).

FAR 2303

90

CAViTY iNFiLL (Refer to Section A)

Rw

Rt(win)

Rt(sum)

(a) Nil

51

1.2

1.2

(b) 75 Gold Batts 1.5

54

2.6

2.4

(c) 88 Soundscreen 2.5

55

3.7

3.4

WALL THICKNESS mm

ThERmAL

161

externAl Side

(a) Nil

50

1.3

1.2

As per system
specification.

(b) 75 Gold Batts 1.5

53

2.7

2.5

(c) 88 Soundscreen 2.5

54

3.7

3.4

internAl Side
2 x 13mm GYPROCK
FYRCHEK plasterboard.

The Red Book

sTud dEPTh mm

1 x 16mm GYPROCK
FYRCHEK plasterboard.

CsR 698

FAR 2303

externAl Side
As per system specification.

90/90/90*

90/90/90

WALL LiNiNgs

WALL THICKNESS mm

165

C29

Timber Frame External Wall systems Commercial ExpressWall


sYsTEm sPECiFiCATioN

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 905a shown)

PKA-055

Cemintel Commercial ExpressWall system.


Sarking.
1 x 16mm GYPROCK FYRCHEK MR plasterboard fixed to
framing.
Timber stud framing as required.
1 layer x 10mm GYPROCK plasterboard CD fixed to framing.
NOTES: *ACR = Axial Capacity Reduction. (Refer to Table C3).

FRL
Report/Opinion

sYsTEm
N

WALL LiNiNgs

CsR 905

sTud dEPTh mm

90

CAViTY iNFiLL (Refer to Section A)

Rw

Rt(win)

ThERmAL
Rt(sum)

(a) Nil

41

1.2

1.1

(b) 75 Gold Batts 1.5

46

2.6

2.4

(c) TSB4/ASB4 Polyester

45

externAl Side of frAMing


1 layer x 16mm
GYPROCK FYRCHEK MR
plasterboard.

60/60/60*
from outside only
* ACR Group 2

internAl Side of frAMing


1 layer x 10mm
GYPROCK plasterboard
CD fixed to framing.

FAR 2303

WALL THICKNESS mm

sYsTEm sPECiFiCATioN

160

ACousTiC
oPiNioN

TYPiCAL LAYouT (CsR 936a shown)

Cemintel Commercial ExpressWall system.

PKA-055

150mm thick hollow block masonry wall.


Timber studs at 600mm maximum centres with 40mm
minimum gap and no ties to masonry.
Cavity insulation as per system table.
Lining material as per system table.
NOTES:
To achieve stated acoustic performance masonry must be
a minimum of 140mm thick and 180kg/m2 laid.
FRL
Report/Opinion

sYsTEm
N

WALL LiNiNgs

CsR 936
externAl Side

//

Masonry veneer
block wall with 1 x
9mm. CSR Cemintel
ExpressWall cladding
system.
internAl Side
1 x 13mm GYPROCK
Plasterboard CD.

C30

sTud dEPTh mm
CAViTY iNFiLL (Refer to Section A)

90

ThERmAL

Rw / Rw+Ctr

Rt(win)

Rt(sum)

(a) Nil

53/39

0.8

0.8

(b) 75 Gold Batts 1.5

59/45

2.4

2.2

(c) 75 Soundscreen 2.0

59/45

2.9

2.7

WALL THICKNESS mm

345

The Red Book

Column and Beam systems


Fig C1: TimBER BEAm ENCAsEmENT sYsTEm
(Third layer must be fixed to second layer specifications)

sYsTEm sPECiFiCATioN

The CSR Gyprock Timber Column and Beam Encasement


Systems provide up to 120 minutes structural fire resistance
to timber column and beam sections.

Fix ceiling layer


before applying
layer to beam

All nails must have a minimum penetration into the timber


of 20mm minimum for FRL up to 90// and a minimum
penetration of 30mm for FRL 120//.

Tape and set


external angle

Fix External Angle


Bead and set corners

FRL
Report/Opinion

sYsTEm
N

75mm
max.

WALL LiNiNgs

CsR 493
1 x 13mm
GYPROCK
FYRCHEK
plasterboard.

30/ /
CSIRO
FCO 1494

CsR 494
2 x 13mm
GYPROCK
FYRCHEK
plasterboard.

60/ /
CSIRO
FCO 1494

75mm
max.

CsR 496
2 x 16mm
GYPROCK
FYRCHEK
plasterboard.

90/ /
CSIRO
FCO 1494

CsR 498

120/ /
CSIRO
FCO 1494

3 x 13mm
GYPROCK
FYRCHEK
plasterboard.

Nail fix each layer


at 200mm max.
horizontal and
vertical centres
200mm max.

300mm max.

Offset Butt Joints in


consecutive layers
by 300mm min.

Nail fix butt


joints at 200mm
max. centres
200mm max.

Apply External
Angle Bead to all
corners and set

The Red Book

200mm
max.

C31

Fig C2: iNsTALLATioN dETAiL gYPRoCK PLAsTERBoARd


TimBER sTud hoRiZoNTAL shEETiNg AdhEsiVE/FAsTENER FixiNg
For additional information, refer to GYP547, Gyprock Residential Installation Guide

NoN-FiRE RATEd
Temporary fastener through
block at every second stud

Form butt joints on or


between studs as required by
level of finish (back-block butt
joints formed between studs)
Stagger butt joints on
adjacent sheets and on
opposite sides of wall by
one stud space minimum

200mm
min. from fastener
Nails 150mm max.
Screws 200mm max.

300mm
max.

Stagger fasteners at butt


joints

300mm
max.

200mm
min. from
fastener
CSR Gyprock Acrylic
Stud Adhesive

Fixing specifications
Nails,
Screws &
Adhesive

Refer to Section A

Location

Fixing & spacing

Field

Sheet
Width
900mm
1200mm
1350mm

Adhesive Daubs at
300mm max. centres
and 200mm min. from
fastener points
Adhesive
Daubs across board
3 daubs
4 daubs
5 daubs

Recessed
Edges

Nail or screw
at each stud

Butt
Joints on
studs

Nails at 150mm max. or


Screws at 200mm max.

Corners &
Openings

Nails or screws at
300mm max. centres

SUITABLE FOR:

300mm
max.

One layer of GYPROCK


Plasterboard to each side
of wall
CSR Bradford Insulation
where applicable
Refer to Section Z for
perimeter details

Fasteners at 10 to 16mm
from sheet edges

Fig C3: iNsTALLATioN dETAiL gYPRoCK PLAsTERBoARd


TimBER sTud hoRiZoNTAL shEETiNg FAsTENER FixiNg
For additional information, refer to GYP547, Gyprock Residential Installation Guide

Form butt joints on or


between studs as required by
level of finish (back-block butt
joints formed between studs)
Stagger butt joints on
adjacent sheets and on
opposite sides of wall by
one stud space minimum

NoN-FiRE RATEd
Fixing specifications
Double Nails
50mm apart
at 300mm
max.
centres
OR
Screws
at
400mm
max.
centres

300mm
max.

One layer of GYPROCK


Plasterboard to each side of wall

Nails or
Screws

Refer to Section A

Location

Fixing & spacing

Field

2 Nails 50mm apart at


300mm max. centres
or
1 screw at 400mm
max. centres

Recessed
Edges

1 Nail or 1 Screw
at each stud

Butt
Joints on
studs

Nails at 150mm max. or


Screws at 200mm max.

Butt joints
between
studs

Back-block and fix with


adhesive only

Corners &
Openings

Nails or screws at
300mm max. centres

SUITABLE FOR:

CSR Bradford Insulation


where applicable

Refer to Section Z for


perimeter details

C32

Fasteners at 10 to 16mm
from sheet edges

The Red Book

Fig C4: iNsTALLATioN dETAiL gYPRoCK FYRChEK siNgLE LAYER


TimBER sTud hoRiZoNTAL FAsTENER FixiNg

Nails at 150mm max.


Screws at 300mm max.
One layer of GYPROCK
FYRCHEK Plasterboard
to each side of wall

Nails at 150mm max.


Screws at 300mm max.

FiRE RATEd
Fixing specifications for
horizontal sheeting
Fasteners

Refer to Section A

Location

Fixing & spacing

Field

2 Nails 50mm apart at


300mm max. centres
or
1 Screw at
300mm max. centres

Recessed
Edges

Fasten at each stud

Butt
Joints

Nails at
150mm max. centres
or
Screws at
200mm max. centres.

Corners,
Openings,
Top &
Bottom

Nails at
150mm max. centres
or
Screws at
300mm max. centres

Where horizontal joints are


not backed by noggings,
stagger all horizontal joints
300mm minimum

300mm min.

300mm
max.

2 Nails
50mm
apart or
1 Screw

Studs at 600mm maximum


centres

SUITABLE FOR:

CSR Bradford Insulation


where applicable
Stagger butt joints in
adjacent sheets one stud
minimum

Nails at 150mm max.


Screws at 200mm max.

Refer to Section Z for


perimeter details

Fasteners at 10 to 16mm
from sheet edges

Fig C5: iNsTALLATioN dETAiL gYPRoCK FYRChEK siNgLE LAYER


TimBER sTud VERTiCAL shEETiNg FAsTENER FixiNg
Nails at 150mm max.
Screws at 300mm max.
One layer of GYPROCK
FYRCHEK Plasterboard
to each side of wall

FiRE RATEd
Nails at 150mm max.
Screws at 300mm max.
300mm
max.

2 Nails
50mm
apart or
1 Screw

Studs at 600mm maximum


centres
CSR Bradford Insulation
where applicable

300mm
max.

Fixing specifications for


Vertical sheeting
Fasteners

Refer to Section A

Location

Fixing & spacing

Field

2 Nails 50mm apart


or 1 Screw at 300mm
max. centres

Recessed
Edges

Nails or Screws at
300mm max. centres

Butt
Joints on
noggings

Nails at
150mm max. centres
or
Screws at
200mm max. centres

Corners,
Openings,
Top &
Bottom

Nails at
150mm max. centres
or
Screws at
300mm max. centres

SUITABLE FOR:

Refer to Section Z for


perimeter details
Fasteners at 10 to 16mm
from sheet edges

The Red Book

C33

Fig C6: iNsTALLATioN dETAiL gYPRoCK FYRChEK TWo LAYER


TimBER sTud hoRiZoNTAL shEETiNg FAsTENER FixiNg
Stagger fasteners
at butt joints

FiRE RATEd
Fixing specifications
Nails at 150mm max.
Screws at 300mm max.

Stagger horizontal joints


300mm minimum between
1st and 2nd layer

Nails at 150mm max.


Screws at 300mm max.
300mm
max.

Studs at 600mm maximum


centres

300mm min.

One or two layers of


GYPROCK FYRCHEK
Plasterboard to each side
of wall

2 Nails
50mm
apart or
1 Screw

Fasteners

Refer to Section A

1st Layer

Fixing & spacing

Edges &
Field

Nails or Screws at
600mm max. centres

2nd Layer Fixing & spacing


Field

2 Nails 50mm apart at


300mm max. centres
or
1 Screw at
300mm max. centres

Recessed
Edges

Fasten at each stud

Butt
Joints

Nails at
150mm max. centres
or
Screws at
200mm max. centres.

Corners &
Openings

Nails at
150mm max. centres
or
Screws at
300mm max. centres

NOTE:
Second layer butt joints may
be formed between studs with
laminating screws at 200mm max.
centres each side of joint.

600mm
max.

CSR Bradford Insulation


where applicable
Nails at 150mm max.
Screws at 200mm max.

Stagger butt joints in


adjacent sheets and
between 1st and 2nd
layers by one stud
minimum

SUITABLE FOR:

Refer to Section Z for


perimeter details

Fasteners at 10 to 16mm
from sheet edges

Fig C7: iNsTALLATioN dETAiL TimBER sTud WiTh REsiLiENT mouNTEd FuRRiNg ChANNEL
gYPRoCK FYRChEK TWo LAYER hoRiZoNTAL shEETiNg sCREW FixiNg
Rondo Track or Angle
fixed to ceiling frame

FiRE RATEd

Rondo Furring Channel at


600mm maximum centres

Fixing specifications

One or two layers of


GYPROCK FYRCHEK
Plasterboard to each side
of wall

300mm
max.

Stagger horizontal joints


300mm minimum between
1st and 2nd layer

300mm min.
600mm
max.

Stagger butt joints by


one stud minimum
300mm
max.

CSR Bradford Insulation


where applicable

Refer to Section Z for


perimeter details

Refer to Section A

1st Layer

Fixing & spacing

Edges &
Field

Screws at 600mm max.


centres

2nd Layer Fixing & spacing

CSR Gyprock Resilient


Mounts to each stud at
1200mm max. from tracks
and 1200mm max. centres

Studs at 600mm maximum


centres

Fasteners

Field

Screws at 300mm max.


centres

Recessed
Edges

Screw at each stud

Butt
Joints

Screws at
200mm max. centres

Corners &
Openings

Screws at
300mm max. centres

NOTE:
Single layer systems are fixed to the
same specifications as detailed for
the 2nd layer.
Second layer butt joints may
be formed between studs with
laminating screws at 200mm max.
centres each side of joint.

200mm
max.
SUITABLE FOR:

Rondo Track or
Angle fixed to floor

C34

Fasteners at 10 to 16mm
from sheet edges

The Red Book

Fig C8: iNsTALLATioN dETAiL gYPRoCK FYRChEK ThREE LAYER


TimBER sTud hoRiZoNTAL oR VERTiCAL shEETiNg FAsTENER FixiNg
FiRE RATEd
Fixing specifications for
Vertical sheeting (shown)

600mm

600mm

Fasteners

Nails or Screws
Refer to Section A

1st Layer

Fixing & spacing

Recessed
Edges,
Field,
Corners &
Openings

Screws or Nails at
600mm max. centres
on studs

2nd Layer Fixing & spacing

300mm

300mm

Recessed
Edges

Screws or Nails at
300mm max. centres
on studs

Field

1 Screw or 2 Nails at
300mm max. centres
on studs

Butt Joints Laminating Screws at


200mm max. centres
Corners &
Openings

Studs at 600mm maximum


centres
400mm

Offset all joints 300mm


min. from previous layer

400mm

Screws at 300mm max.


centres
or
Nails at 150mm max.
centres

3rd Layer

Fixing & spacing

Recessed
Edges,
Field,
Corners &
Openings

Laminating screws at
400x400mm max. grid

Butt Joints Laminating screws at


200mm max. centres

400mm
Refer to Section Z for
perimeter details

FiRE RATEd
Fixing specifications for
horizontal sheeting

SUITABLE FOR:

Fasteners

Nails or Screws
Refer to Section A

1st Layer

Fixing & spacing

Recessed
Edges,
Field,
Corners &
Openings

Screws or Nails at
600mm max. centres
on studs

2nd Layer Fixing & spacing


Recessed
Edges

Screws or Nails at
600mm max. centres
on studs

Field

1 Screw or 2 Nails at
300mm max. centres
on studs

Butt Joints Laminating Screws at


200mm max. centres
Corners &
Openings

Screws at 300mm max.


centres
or
Nails at 150mm max.
centres

3rd Layer

Fixing & spacing

Recessed
Edges,
Field,
Corners &
Openings

Laminating screws at
400x400mm max. grid

Butt Joints Laminating screws at


200mm max. centres

The Red Book

C35

Fig C9: iNsTALLATioN dETAiL CEmiNsEAl WALLBoARd


TimBER sTud hoRiZoNTAL shEETiNg AdhEsiVE/FAsTENER FixiNg
For additional information, refer to FC101, Cemintel Wet Area Systems guide
Temporary fastener through
block at every second stud
until adhesive sets

NoN-FiRE RATEd
Fixing specifications

Stagger butt joints in


adjacent sheets and on
opposite sides of wall by
one stud minimum

200mm
max.

200mm
max.

200mm
max.

Daubs of CSR Gyprock


Acrylic Stud Adhesive

Nails &
Adhesive

Refer to Section A

Location

Fixing & spacing

Field

Adhesive Daubs at
230mm max. centres
and 200mm min. from
fastener points
3 daubs
4 daubs
5 daubs

Sheet
Width
900mm
1200mm
1350mm
Top &
Bottom
Plates

Nails at 200mm
maximum centres

Recessed
Edges

Nails at
each stud

Butt
Joints

Nails at
200mm max. centres.

Corners &
Openings

Nails at
200mm max. centres

Studs at 600mm maximum


centres

SUITABLE FOR:

One layer of CSR Fibre


Cement Wallboard to
each side of wall

230mm
max.

CSR Bradford Insulation


where applicable

200mm
min.

Refer to Section Z for


perimeter details

Fasteners at 12mm min.


from sheet edges and
50mm min. from sheet
corners

Fig C10: iNsTALLATioN dETAiL gYPRoCK FYRChEK + CEmiNsEAL WALLBoARd


TimBER sTud hoRiZoNTAL shEETiNg FAsTENER FixiNg
For additional information, refer to FC101, Cemintel Wet Area Systems guide

FiRE RATEd
Studs at 600mm maximum
centres

Fixing specifications
200mm
max.

Stagger horizontal joints


300mm minimum between
1st and 2nd layer
300mm
max.

Fasten GYPROCK
FYRCHEK plasterboard
at 600mm maximum
centres and 10 to 16mm
from sheet edges
CSR Bradford Insulation
where applicable
One layer of GYPROCK
FYRCHEK plasterboard
and one layer of CSR
Fibre Cement Wallboard
to each side of wall

Refer to Section A

1st Layer

Fixing & spacing

Edges &
Field

Nails or Screws at
600mm max. centres

2nd Layer Fixing & spacing


Field

Nails at 300mm max.


centres
For tiled areas Nails
at 200mm max. centres

Top &
Bottom
Plates

Nails at
200mm max. centres

Recessed
Edges

Nails at
each stud

Butt
Joints

Nails at
200mm max. centres

Corners &
Openings

Nails at
200mm max. centres

200mm
max.

600mm max.

300mm min.

Stagger butt joints in


adjacent sheets and
between 1st and 2nd layer
by one stud minimum

Fasteners

SUITABLE FOR:
200mm
max.

Refer to Section Z for


perimeter details
Fasteners at 12mm min. from
sheet edges and 50mm min.
from sheet corners

C36

The Red Book

Fig C11: iNsTALLATioN dETAiL. CsR CEmiNsEAL TExTuRE BAsE shEET


ExTERNAL sidE oF WALL TimBER sTud
For additional information, refer to FC122, Cemintel Texture Base Sheet & Texture Coating System guide

200mm max.

Fasteners 50mm
min. from sheet
corners

One layer of GYPROCK


FYRCHEK MR
Plasterboard fixed to
studs

FiRE RATEd
Fixing specifications

Joint and finish outer


layer only (refer to
Jointing specification).
All joints to be formed on
framing

200mm
max.

200mm
max.

Noggings at 1350mm max

CSR Bradford Insulation


where applicable

Refer to Section A

1st Layer

Fixing & spacing

Edges &
Field

Nails or Screws at
600mm max. centres

2nd Layer Fixing & spacing

Sarking

Studs at 600mm maximum


centres

Fasteners

Recessed
Joints,
Field,
Top &
Bottom
Plates

Nails to framing at
200mm max. centres

Corners &
Openings

Nails at
200mm max. centres

SUITABLE FOR:

600mm
max.

200mm
max.

One layer of CSR Fibre


Cement Texture Base
Sheet

Fasteners 12mm min.


from sheet edges

Fasteners 50mm min.


from sheet corners

NOTE: Fixing spacings for Cemintel Texture Base Sheet may need to be reduced to meet wind loadings. Refer to
publication NFC122, Cemintel Texture Base Sheet & Texture Coating System guide.

The Red Book

C37

Notes

C38

The Red Book

Section D

Masonry Wall Systems

Contents
Stud Selection Tables

D2 D3

Introduction

D3

Design Considerations

D3 D4

Installation

D5

Components

D5

System Specifications
Stud One Side

D6 D8

Stud Both Sides

D9 D11

Stud and Furring Channel

D12 D13

Resilient Mount/Furring Channel

D14 D15

CSR Hebel Systems

D16 D18

FRL Upgrade

D19 D20

Concrete Column Encasement

D21

System Installation Details

The Red Book

D22 D23

D1

Stud Selection Tables


Table D1 and D5 provide stud selection information suitable for Gyprock non-fire rated and fire rated non-loadbearing internal
wall systems that are to be designed for a Uniform Distributed Load (UDL) of 0.25kPa.
Table D2 provides stud selection information suitable for specialised fire rated non-loadbearing wall systems that are required
to be designed for a UDL of 0.35kPa. Refer to Rondo for other design pressures and for loadbearing walls.
TABLE D1: mAximum WALL hEighT WiTh RONDO LiPPED STEEL STuDS NON-LOADBEARiNg WALLS
WALLS gENERALLy (LOAD uDL = 0.25kPa)
Stud Size
Wall Frame and
Lining Configuration

BMT

51
0.5

64
0.75

0.5

0.75

76
1.15

Linings (mm)
600mm max. cts

0.55

0.75

92
1.15

150

0.55

0.75

1.15

0.75

1.15

Maximum Wall Height (m)

10

2.32

2.60

2.72

3.13

3.53

3.20

3.58

4.05

3.61

4.13

4.69

5.33

6.81

13

2.32

2.60

2.72

3.25

3.58

3.24

3.82

4.05

3.61

4.18

4.69

5.37

6.81

16

2.32

2.60

2.75

3.28

3.59

3.25

3.87

4.05

3.61

4.20

4.69

5.37

6.81

TABLE D2: mAximum WALL hEighT WiTh RONDO LiPPED STEEL STuDS NON-LOADBEARiNg WALLS
WALLS Of ShAfTS AND fiRE iSOLATED ExiTS (LOAD uDL = 0.35kPa)
Stud Size
Wall Frame and
Lining Configuration

51

BMT

0.5

64
0.75

0.5

0.75

76
1.15

Linings (mm)
600mm max. cts

0.55

0.75

92
1.15

150

0.55

0.75

1.15

0.75

1.15

Maximum Wall Height (m)

10

2.07

2.34

2.34

2.80

3.15

2.76

3.20

3.62

3.06

3.70

3.81

3.81

3.81

13

2.07

2.34

2.34

2.80

3.17

2.76

3.37

3.62

3.06

3.70

4.20

4.83

5.53

16

2.07

2.34

2.34

2.90

3.18

2.76

3.41

3.62

3.06

3.70

4.20

4.83

5.53

NOTES:
Deflection Limit is span/240 to a maximum of 30mm, in accordance with BCA Specification C1.8.
Tabulated heights do not include axial loads (except self weight) or shelf loading.
Loadings: Table D1 Pultimate = 0.375 kPa, Pservice = 0.25 kPa.
Loadings: Table D2 Pultimate = 0.525 kPa, Pservice = 0.35 kPa.
Walls are not for external applications.
All loadings in accordance with AS1170:2002.
Walls analysed in accordance with AS4600:1996.
Noggings in accordance with Table D3.
Tables have been prepared by Rondo Building Services Pty Ltd.

TABLE D3: NOggiNgS fOR STEEL fRAmiNg


Lining Configuration

Lined One Side*

Wall Height (m)

Number of Noggings
(equally spaced)

0.0 - 3.0

3.0 - 6.0

6.0 - 8.0

NOTES: * Plus noggings at head. Refer to details.

D2

TABLE D4. mAximum SPAciNg Of WALL SuPPORT


cLiPS fOR fuRRiNg chANNELS.
(LOAD uDL = 0.35kPa)
Rondo Furring Channel Part N

Maximum Spacing of Clips (mm)

308 (16mm)

900

129 (28mm)
NOTES: Support clips include
direct fixing clips.

1200
Gyprock

Resilient Mounts and Rondo

The Red Book

TABLE D5: mAximum TimBER STuD hEighT


NON-LOADBEARiNg WALLS ShEETED WiTh gyPROcK PLASTERBOARD OR cEmiNSEAL WALLBOARD
uNifORm DiSTRiBuTED LOAD (uDL) = 0.25kPa
Wall Frame

Timber Grade

and Sheeting

Stud Thickness (mm)

Configuration

Stud Depth (mm)

600mm cts.

F5
35

F8
45

35

F11
45

35

MGP 10
45

35

45

MGP 12

MGP 15

35

45

35

45

Maximum Stud Height (m)

70

2.7

2.9

2.9

3.2

3.1

3.3

3.0

3.3

3.3

3.6

3.5

3.8

90

3.4

3.7

3.8

4.1

4.0

4.3

3.9

4.2

4.2

4.6

4.5

4.9

120

4.6

5.0

5.0

5.5

5.3

5.8

5.2

5.7

5.6

6.0

6.0

6.0

NOTES:
Stud heights have been determined based on a maximum deflection of H240 or 30mm maximum.
Noggings at 1350mm maximum centres, measured vertically.

Introduction
Gyprock plasterboard and CeminSeal Wallboard can
be used with masonry walls for effective fire and acoustic
solutions. These linings can eliminate the need for render,
increase the fire rating of the masonry, or provide an acoustic
performance to meet sound transmission and sound impact
ratings.
Systems incorporating masonry and an insulated cavity are
generally used where there is a requirement for excellent
acoustic performance and discontinuous construction. The
provision of a cavity also allows the inclusion of services.
Gyprock plasterboard may be directly applied to the
masonry substrate, screw fixed to metal furring channels
that are fixed to the masonry, or may be fixed to separate
stud framing. CeminSeal Wallboard may be fixed to furring
channels or studs.
Systems in this section are suitable for a wide range of
masonry products. These are typically clay and concrete
blocks, autoclaved aerated concrete blocks and panels, and
may include cast concrete elements. Minimum performance
conditions apply to the substrates to achieve the system
performance values, and these are stated in the system
specifications. Specific fixing details apply to each type of
substrate.
These wall systems are generally used in internal applications
in commercial, industrial, institutional, domestic and high-rise
domestic construction, or in the renovation of older buildings.
A number of systems for external masonry veneer walls can
be found in Section B and Section C.

The Red Book

Design
Considerations
Structural Performance
All wall elements must be designed for the applied loads.
Vertical loads may be supported by the masonry element
of the wall, or for non-fire rated walls, by the stud framing.
Lateral loads should be considered separately for framed
and masonry parts of a wall. To achieve the specified sound
performance, ties from masonry to the stud framing must
not be used.
framed Wall Elements
Guidance is given in Tables D1, D2, & D5 for the selection of
Rondo studs and for timber studs in non-loadbearing internal
walls only for 0.25kPa and 0.35kPa. For other brands of
studs, studs that are required to be loadbearing, and studs
subject to higher lateral pressures, contact the manufacturer
for design information. Maximum spans for Rondo furring
channels are given in Table D4.
Tall multi-residential buildings often have exterior operable
doors and windows, resulting in internal walls being subject
to wind pressure. In these cases, walls must be designed
for the appropriate loads.
Stud frames that are part of a masonry wall system may be
loadbearing. A qualified person must complete the structural
design of loadbearing wall systems. Walls with shelving
attached are considered loadbearing.

D3

Further information on the design of stud walls is given in


Sections B and C.
Walls lined with GYPROCK plasterboard designed as
loadbearing, and non-loadbearing walls selected from Tables
D1, D2 and D5, meet the requirements of BCA Specification
C1.8 Clause 3.4 Walls generally.
masonry Wall Elements
All brick and block wall elements are to be designed in
accordance with AS3700 Masonry Structures. Concrete
walls must be designed to AS3600: Concrete Structures, and
CSR Hebel Powerpanel must be designed in accordance
with CSR Hebel literature.

fire Resistance
For systems without a stated Fire Resistance Level (FRL),
the system FRL is equal to the FRL of the masonry wall
element. The FRL of masonry walls is dependant on the
height and width of the wall; contact the manufacturer for
more information.
To achieve the required fire performance of a wall, it is
essential that installation is in accordance with the masonry
manufacturers details and relevant installation standards. This
should include fire sealing at the wall head and perimeters,
and filling of mortar joints. All gaps and penetrations should
be effectively fire sealed.
Vermiculite plaster has no capacity to accommodate building
movement and may not be suitable for use as a general
purpose fire rated caulking. Its use is specified in some wall/
ceiling junctions. Refer to the Gyprock Ceiling Systems
Installation Guide, NGYP570.
In systems with Gyprock Fyrchek plasterboard fixed to
furring channels, fixing, jointing and fire sealing must be
in accordance with Section B of this manual. FYRCHEK
plasterboard must be fully screw fixed, and Gyprock Acrylic
Stud Adhesive must not be relied on.

Systems that use only resilient mounts with furring


channels to create a cavity do not meet the requirements
of discontinuous construction, although may be used in the
Northern Territory where an impact rating is required. The
installation of services in these systems is not recommended
as they can bridge the gap between the masonry and the
linings.
The acoustic performance of wall systems may be affected
by:
Sound flanking.
The effectiveness of workmanship and caulking.
The presence and treatment of penetrations.
The inclusion of structural elements and bridging items
such as ties.
Reducing the stated or implied cavity sizes.
The acoustic performance of wall systems will not be reduced
by:
The addition of Gyprock plasterboard or Cemintel
linings.
The use of deeper studs or larger cavities.
The use of timber studs of at least equal depth in lieu of
steel studs.
Omitting the lining direct fixed to masonry (except in Hebel
systems).
Refer to Section A for detailed acoustic information.
Perimeter Sealing
To attain the stated R w in systems that do not rely on
plasterboard for the fire rating, use Gyprock Wet Area
Acrylic Sealant, Gyprock Fire Mastic or other tested
acoustic rated material of equivalent or better performance.

Acoustic Performance
The acoustic performance of some systems is dependant
on a minimum Rw of the masonry wall element. This is to
be the tested performance of the masonry without render
or sheet linings, and must be verified by the masonry unit
manufacturer.
Installation of the masonry element of the wall must be in
accordance with the manufacturers details for the tested
product.
Systems that meet the BCA requirements for discontinuous
construction are noted in the system specifications. These
have studs that are separated from the masonry by at least
12mm. The plasterboard lining on the studs (the wall leaf)
therefore has a separation of at least 12mm plus the depth
of the stud, which exceeds the BCA minimum of 20mm.
Ties between masonry and stud framing must not be used.

D4

The Red Book

Installation
masonry

For masonry with any direct fixed lining or lining fixed to


furring channels:
At control joints in masonry (Refer to masonry
manufacturer.)

All brick and block walls are to be installed in accordance


with AS3700 Masonry Structures. CSR Hebel Powerpanel
must be installed in accordance with CSR Hebel literature.

At 12m maximum centres.

framing

Non-tiled internal walls with fibre cement outer layer: at


7.2m maximum centres.

For detailed information on wall junctions, intersections,


frame attachments and penetrations, refer to relevant
installation manuals.

At change of substrate material.


For stud framed wall elements:

Tiled internal walls with fibre cement outer layer: at 4.2m


maximum centres.

Manual NGYP544, Gyprock Steel Frame Wall Systems


Installation Guide has detailed information on the installation
of steel stud framing.

Walls with plasterboard outer layer: at 12m maximum


centres.

Wallboard & Plasterboard fixing

At changes of lining material.

Walls may be built to achieve a particular Level of Finish


as defined in AS/NZS2589.1. The Level of Finish specified
can have requirements for frame alignment, jointing, back
blocking methods and sheet orientation. CeminSeal
Wallboard and Gyprock plasterboard may be installed
vertically or horizontally, although for some Levels of Finish
horizontal sheeting must be used.

At junctions with other wall elements.

Components
Lining & fixing materials
Refer to Section A of this manual for detailed information
on Gyprock and Cemintel lining products, masonry
adhesive, and for fastener specifications for fixing GYPROCK
plasterboard to steel studs and furring channel.

Except for fire grade plasterboard, fixing to framing may be


fastener only or combination fastener/adhesive. Plasterboard
fixed direct to masonry may be adhesive daub fixed, full bed
adhesive fixed, or mechanically fixed. A nominal 5mm has
been allowed for adhesive thickness.

Gyprock Masonry Adhesive is a fast and convenient


method of fixing GYPROCK plasterboard systems to
masonry substrates. Gyprock Acrylic Stud Adhesive is
used for fixing non-fire grade linings to framing.

Jointing & finishing

framing

Refer to the Gyprock Residential Installation Guide,


NGYP547 and Cemintel Wet Area Lining Systems,
NFC101 for detailed jointing and finishing information.

CSR recommends steel components manufactured by


Rondo Building Services Pty Ltd. Additional information
on the steel components can be obtained from the Rondo
Building Services Pty Ltd, telephone 1300 367 663.

It should be noted that:


Multi-layered systems only require jointing and finishing of
the outer layer.
It is recommended that a water resistant taping
compound, such as Gyprock Wet Area Base Coat be
used at horizontal and vertical joints within wet areas such
as showers.

control Joints
Control joints must be installed to allow for structural
movement. Allowance for movement must be made through
the masonry and any direct fixed lining, and through framed
wall elements.

Fixing clips include CSR Resilient Mount, Rondo direct fixing


clips N237, Beta-Fix and STSC clips. Furring channels part
N308 or N129 are to be fitted into wall track part N142 or
N140 respectively at top and bottom.

masonry
For systems in this section, masonry may include clay or
concrete blocks, autoclaved aerated concrete blocks and
panels, and reinforced concrete. Brick and block substrates
shall comply with AS3700.

Control joints must be installed at all construction joints in


the building, and at the following locations:

The Red Book

D5

masonry Wall Systems - Stud One Side


SySTEm SPEcificATiON

AcOuSTic
OPiNiON

TyPicAL LAyOuT (cSR 760 shown)

PKA-053
Discontinuous
Construction

Lining as per table, fixed to studs.


Steel stud framing, as per table, at 600mm max. centres.
Cavity infill as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
Plasterboard as per system table, direct fixed to masonry.

masonry
Wall
Requirements

SySTEm
N

cSR 737

STuD DEPTh (mm)


WALL LiNiNgS

56/46

57/47

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

57/47

58/48

(c) TSB4/ASB4 Polyester

55/45

56/46

100

128

(a) 75 GW Partition 11kg

56/48

58/50

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

57/49

59/51

(c) TSB4/ASB4 Polyester

55/47

57/49

107

135

1 x 13mm GYPROCK
plasterboard CD.

Refer to Masonry
Wall Manufacturer
for FRL Details

(a) 75 GW Partition 11kg

58/50

59/52

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

59/51

60/53

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

(c) TSB4/ASB4 Polyester

57/49

58/51

107

135

Masonry side

(a) 75 GW Partition 11kg

61/54

62/55

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

62/55

63/56

(c) TSB4/ASB4 Polyester

60/53

61/54

120

148

stud side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

D6

ADDITIONAL WALL THICKNESS mm

Masonry side

stud side

cSR 762

ADDITIONAL WALL THICKNESS mm

Masonry side

stud side

cSR 761

Rw / Rw+ctr

(a) 75 GW Partition 11kg

1 x 6mm CeminSeal
Wallboard.

Tested
Brick,
Block or
concrete
Wall with Rw
> 41

92

Masonry side

stud side

cSR 760

cAViTy iNfiLL (Refer to Section A)

64

ADDITIONAL WALL THICKNESS mm

ADDITIONAL WALL THICKNESS mm

The Red Book

masonry Wall Systems - Stud One Side


SySTEm SPEcificATiON

AcOuSTic
OPiNiON

TyPicAL LAyOuT (cSR 765 shown)

PKA-053
Discontinuous
Construction

Lining as per table, fixed to studs.


Steel stud framing, as per table, at 600mm max. centres.
Cavity infill as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
Plasterboard as per system table, direct fixed to masonry.

masonry
Wall
Requirements

SySTEm
N

cSR 763

STuD DEPTh (mm)


WALL LiNiNgS

59/49

60/50

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

60/50

61/51

(c) TSB4/ASB4 Polyester

58/48

59/49

100

128

(a) 75 GW Partition 11kg

59/51

61/53

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

60/52

62/54

(c) TSB4/ASB4 Polyester

58/50

60/52

107

135

1 x 13mm GYPROCK
plasterboard CD.

Refer to Masonry
Wall Manufacturer
for FRL Details

(a) 75 GW Partition 11kg

61/53

62/55

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

62/54

63/56

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

(c) TSB4/ASB4 Polyester

60/52

61/54

107

135

Masonry side

(a) 75 GW Partition 11kg

64/57

65/58

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

65/58

66/59

(c) TSB4/ASB4 Polyester

63/56

64/57

120

148

stud side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

The Red Book

ADDITIONAL WALL THICKNESS mm

Masonry side

stud side

cSR 766

ADDITIONAL WALL THICKNESS mm

Masonry side

stud side

cSR 765

Rw / Rw+ctr

(a) 75 GW Partition 11kg

1 x 6mm CeminSeal
Wallboard.

Tested
Brick,
Block or
concrete
Wall with Rw
> 44

92

Masonry side

stud side

cSR 764

cAViTy iNfiLL (Refer to Section A)

64

ADDITIONAL WALL THICKNESS mm

ADDITIONAL WALL THICKNESS mm

D7

masonry Wall Systems - Stud One Side


SySTEm SPEcificATiON

AcOuSTic
OPiNiON

TyPicAL LAyOuT (cSR 738 shown)

PKA-053
Discontinuous
Construction

Lining as per table, fixed to studs.


Steel stud framing, as per table, at 600mm max. centres.
Cavity infill as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
Plasterboard as per system table, direct fixed to masonry.

masonry
Wall
Requirements

SySTEm
N

cSR 738

STuD DEPTh (mm)


WALL LiNiNgS

61/51

62/53

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

62/52

63/54

(c) TSB4/ASB4 Polyester

60/50

61/52

100

128

(a) 75 GW Partition 11kg

60/51

62/54

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

61/52

63/55

(c) TSB4/ASB4 Polyester

59/50

61/53

104

132

1 x 10mm GYPROCK
plasterboard CD.

Refer to Masonry
Wall Manufacturer
for FRL Details

(a) 75 GW Partition 11kg

61/53

63/55

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

62/54

64/56

(c) TSB4/ASB4 Polyester

60/52

62/54

107

135

1 x 13mm GYPROCK
plasterboard CD.

(a) 75 GW Partition 11kg

63/55

64/57

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

64/56

65/58

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

(c) TSB4/ASB4 Polyester

62/54

63/56

107

135

Masonry side

(a) 75 GW Partition 11kg

66/59

67/60

1 x 13mm GYPROCK
plasterboard CD

(b) 90 Gold Batts 2.0

67/60

68/61

(c) TSB4/ASB4 Polyester

65/58

66/59

120

148

stud side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

D8

ADDITIONAL WALL THICKNESS mm

Masonry side

stud side

cSR 769

ADDITIONAL WALL THICKNESS mm

Masonry side

stud side

cSR 768

ADDITIONAL WALL THICKNESS mm

Masonry side

stud side

cSR 767

Rw / Rw+ctr

(a) 75 GW Partition 11kg

1 x 6mm CeminSeal
Wallboard.

Tested
Brick,
Block or
concrete
Wall with Rw
> 46

92

Masonry side

stud side

cSR 739

cAViTy iNfiLL (Refer to Section A)

64

ADDITIONAL WALL THICKNESS mm

ADDITIONAL WALL THICKNESS mm

The Red Book

masonry Wall Systems - Stud Both Sides


SySTEm SPEcificATiON

AcOuSTic
OPiNiON

TyPicAL LAyOuT (cSR 775 shown)

PKA-053

Lining as per table, fixed to studs.

Discontinuous
Construction

Steel stud framing, as per table, at 600mm max. centres.


Cavity infill, as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
12mm minimum cavity between masonry and framing.
Steel stud framing, as per table, at 600mm max. centres.
Cavity infill, as per table.
Lining as per table, fixed to studs.

masonry
Wall
Requirements

SySTEm
N

STuD DEPTh (mm)


WALL LiNiNgS

cAViTy iNfiLL (both sides)


(Refer to Section A)

cSR 774

61/46

Both sides

(b) 90 Gold Batts 2.0

61/46

62/47

1 x 6mm CeminSeal
Wallboard.

(c) TSB4/ASB4 Polyester

58/43

59/44

164

220

(a) 75 GW Partition 11kg

59/45

60/47

Both sides

(b) 90 Gold Batts 2.0

60/46

61/48

1 x 10mm GYPROCK
plasterboard CD.

(c) TSB4/ASB4 Polyester

57/43

58/45

172

228

(a) 75 GW Partition 11kg

60/47

62/49

Both sides

(b) 90 Gold Batts 2.0

61/48

63/50

1 x 13mm GYPROCK
plasterboard CD.

(c) TSB4/ASB4 Polyester

58/45

60/47

178

234

(a) 75 GW Partition 11kg

62/49

63/50

(b) 90 Gold Batts 2.0

63/50

64/51

(c) TSB4/ASB4 Polyester

60/47

61/48

178

234

ADDITIONAL WALL THICKNESS mm

cSR 780

ADDITIONAL WALL THICKNESS mm

cSR 781
Both sides
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

ADDITIONAL WALL THICKNESS mm

The Red Book

Rw / Rw+ctr
60/45

cSR 775

Refer to Masonry
Wall Manufacturer
for FRL Details

92

(a) 75 GW Partition 11kg

ADDITIONAL WALL THICKNESS mm

Tested
Brick,
Block or
concrete
Wall with Rw
> 41

64

D9

masonry Wall Systems - Stud Both Sides


SySTEm SPEcificATiON

AcOuSTic
OPiNiON

TyPicAL LAyOuT (cSR 784 shown)

PKA-053

Lining as per table, fixed to studs.

Discontinuous
Construction

Steel stud framing, as per table, at 600mm max. centres.


Cavity infill, as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
12mm minimum cavity between masonry and framing.
Steel stud framing, as per table, at 600mm max. centres.
Cavity infill, as per table.
Lining as per table, fixed to studs.

masonry
Wall
Requirements

SySTEm
N

STuD DEPTh (mm)


WALL LiNiNgS

cAViTy iNfiLL (both sides)


(Refer to Section A)

cSR 776

63/48

Both sides

(b) 90 Gold Batts 2.0

63/48

64/49

1 x 6mm CeminSeal
Wallboard.

(c) TSB4/ASB4 Polyester

60/45

61/46

164

220

(a) 75 GW Partition 11kg

62/48

63/50

Both sides

(b) 90 Gold Batts 2.0

63/49

64/51

1 x 10mm GYPROCK
plasterboard CD.

(c) TSB4/ASB4 Polyester

60/46

61/48

172

228

(a) 75 GW Partition 11kg

63/50

64/51

Both sides

(b) 90 Gold Batts 2.0

64/51

65/52

1 x 13mm GYPROCK
plasterboard CD.

(c) TSB4/ASB4 Polyester

61/48

62/49

178

234

(a) 75 GW Partition 11kg

64/51

66/53

(b) 90 Gold Batts 2.0

65/52

67/54

(c) TSB4/ASB4 Polyester

62/49

64/51

178

234

ADDITIONAL WALL THICKNESS mm

cSR 783

ADDITIONAL WALL THICKNESS mm

cSR 784
Both sides
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

ADDITIONAL WALL THICKNESS mm

D10

Rw / Rw+ctr
62/47

cSR 777

Refer to Masonry
Wall Manufacturer
for FRL Details

92

(a) 75 GW Partition 11kg

ADDITIONAL WALL THICKNESS mm

Tested
Brick,
Block or
concrete
Wall with Rw
> 44

64

The Red Book

masonry Wall Systems - Stud Both Sides


SySTEm SPEcificATiON

AcOuSTic
OPiNiON

TyPicAL LAyOuT (cSR 778 shown)

PKA-053

Lining as per table, fixed to studs.

Discontinuous
Construction

Steel stud framing, as per table, at 600mm max. centres.


Cavity infill, as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
12mm minimum cavity between masonry and framing.
Steel stud framing, as per table, at 600mm max. centres.
Cavity infill, as per table.
Lining as per table, fixed to studs.

masonry
Wall
Requirements

SySTEm
N

STuD DEPTh (mm)


WALL LiNiNgS

cAViTy iNfiLL (both sides)


(Refer to Section A)

cSR 778

66/51

Both sides

(b) 90 Gold Batts 2.0

66/51

67/52

1 x 6mm CeminSeal
Wallboard.

(c) TSB4/ASB4 Polyester

63/48

64/49

164

220

(a) 75 GW Partition 11kg

64/50

66/53

Both sides

(b) 90 Gold Batts 2.0

65/51

67/54

1 x 10mm GYPROCK
plasterboard CD.

(c) TSB4/ASB4 Polyester

62/48

64/51

172

228

(a) 75 GW Partition 11kg

65/52

67/54

Both sides

(b) 90 Gold Batts 2.0

66/53

68/55

1 x 13mm GYPROCK
plasterboard CD.

(c) TSB4/ASB4 Polyester

63/50

65/52

178

234

(a) 75 GW Partition 11kg

67/54

68/55

(b) 90 Gold Batts 2.0

68/55

69/56

(c) TSB4/ASB4 Polyester

65/52

66/53

178

234

ADDITIONAL WALL THICKNESS mm

cSR 787

ADDITIONAL WALL THICKNESS mm

cSR 788
Both sides
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

ADDITIONAL WALL THICKNESS mm

The Red Book

Rw / Rw+ctr
65/50

cSR 779

Refer to Masonry
Wall Manufacturer
for FRL Details

92

(a) 75 GW Partition 11kg

ADDITIONAL WALL THICKNESS mm

Tested
Brick,
Block or
concrete
Wall with Rw
> 46

64

D11

masonry Wall Systems - Stud and furring channel


SySTEm SPEcificATiON

TyPicAL LAyOuT (cSR 540 shown)

AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction

Lining as per table, fixed to studs.


Steel stud framing, as per table, at 600mm max. centres.
Cavity infill, as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
28mm furring channel, fixed to masonry with 40mm
cavity.
Furring cavity infill, as per table.
Lining as per table, fixed to furring.

masonry
Wall
Requirements

STuD DEPTh (mm)


SySTEm
N

WALL LiNiNgS

cSR 540
Both sides

Tested
Brick,
Block or
concrete
Wall with
Rw > 41

1 x 13mm
GYPROCK
plasterboard CD.

cSR 541

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

57/45

59/47

(b) 75 GW Partition 11kg

(b) 50 GW Partition 11kg

58/46

60/48

(c) TSB4/ASB4 Polyester

(c) TBL1025

55/43

57/45

142

170

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

59/47

60/49

(b) 75 GW Partition 11kg

(b) 50 GW Partition 11kg

60/48

61/50

(c) TSB4/ASB4 Polyester

(c) TBL1025

57/45

58/47

142

170

Both sides
1 x 13mm
GYPROCK
SOUNDCHEK
plasterboard.

cSR 542
Both sides
1 x 13mm
GYPROCK
plasterboard CD.

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

60/48

62/50

(b) 75 GW Partition 11kg

(b) 50 GW Partition 14kg

62/50

64/52

(c) TSB4/ASB4 Polyester

(c) TBL1025

58/46

60/48

142

170

ADDITIONAL WALL THICKNESS mm

Refer to
Masonry Wall
Manufacturer
for FRL Details

cSR 543

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

62/50

63/52

(b) 75 GW Partition 11kg

(b) 50 GW Partition 11kg

63/51

64/53

(c) TSB4/ASB4 Polyester

(c) TBL1025

60/48

61/50

142

170

Both sides
1 x 13mm
GYPROCK
SOUNDCHEK
plasterboard.

ADDITIONAL WALL THICKNESS mm

cSR 548

stud side
1 x 13mm
GYPROCK
plasterboard CD.
Furring side
1 x 6mm
CeminSeal
Wallboard.

D12

Rw / Rw+ctr

(Refer to Section A)

ADDITIONAL WALL THICKNESS mm

Tested
Brick,
Block or
concrete
Wall with
Rw > 44

92

(Refer to Section A)

STuD cAViTy iNfiLL

ADDITIONAL WALL THICKNESS mm

Refer to
Masonry Wall
Manufacturer
for FRL Details

64

fuRRiNg cAViTy
iNfiLL

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

60/48

62/50

(b) 75 GW Partition 11kg

(b) 50 GW Partition 14kg

62/50

64/52

(c) TSB4/ASB4 Polyester

(c) TBL1025

58/46

60/48

135

163

ADDITIONAL WALL THICKNESS mm

The Red Book

masonry Wall Systems - Stud and furring channel


SySTEm SPEcificATiON

TyPicAL LAyOuT (cSR 551 shown)

AcOuSTic
OPiNiON
PKA-053
Discontinuous
Construction

Lining as per table, fixed to studs.


Steel stud framing, as per table, at 600mm max. centres.
Cavity infill, as per table.
12mm minimum cavity between masonry and framing.
Single Brick, Block or Concrete wall with Rw as stated.
28mm furring channel, fixed to masonry with 40mm
cavity.
Furring cavity infill, as per table.
Lining as per table, fixed to furring.

masonry
Wall
Requirements

STuD DEPTh (mm)


SySTEm
N

WALL LiNiNgS

cSR 549
Both sides
1 x 10mm
GYPROCK
plasterboard CD.

Both sides

Tested
Brick,
Block or
concrete
Wall with
Rw > 46

1 x 13mm
GYPROCK
plasterboard CD.

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

61/48

63/51

(b) 75 GW Partition 11kg

(b) 50 GW Partition 14kg

63/50

65/53

(c) TSB4/ASB4 Polyester

(c) TBL1025

59/46

61/49

136

164

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

62/50

64/52

(b) 75 GW Partition 11kg

(b) 50 GW Partition 11kg

63/51

65/53

(c) TSB4/ASB4 Polyester

(c) TBL1025

60/48

62/50

142

170

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

64/52

65/54

(b) 75 GW Partition 11kg

(b) 50 GW Partition 11kg

65/53

66/55

(c) TSB4/ASB4 Polyester

(c) TBL1025

62/50

63/52

142

170

Both sides

Refer to
Masonry Wall
Manufacturer
for FRL Details

1 x 13mm
GYPROCK
SOUNDCHEK
plasterboard.

ADDITIONAL WALL THICKNESS mm

cSR 551

stud side
1 x 13mm
GYPROCK
plasterboard CD.
Furring side
1 x 6mm
CeminSeal
Wallboard.

The Red Book

Rw / Rw+ctr

(Refer to Section A)

ADDITIONAL WALL THICKNESS mm

cSR 545

92

(Refer to Section A)

STuD cAViTy iNfiLL

ADDITIONAL WALL THICKNESS mm

cSR 544

64

fuRRiNg cAViTy
iNfiLL

(a) 50 GW Partition 11kg

(a) 50 GW Partition 11kg

62/50

64/52

(b) 75 GW Partition 11kg

(b) 50 GW Partition 11kg

63/51

65/53

(c) TSB4/ASB4 Polyester

(c) TBL1025

60/48

62/50

135

163

ADDITIONAL WALL THICKNESS mm

D13

masonry Wall Systems - Resilient mount/furring channel


SySTEm SPEcificATiON

TyPicAL LAyOuT (cSR 530/532 shown)

AcOuSTic
OPiNiON
PKA-053
NOT
Deemed
Discontinuous
Construction

Lining as per table, direct fixed to furring.


28mm furring channel at 600mm max. centres, fixed to
masonry with CSR Gyprock Resilient Mounts.
Cavity infill, as per table.
Single Brick, Block or Concrete wall with Rw as stated.
Plasterboard as per system table, direct fixed to masonry.

masonry
Wall
Requirements

SySTEm
N

cSR 530

WALL LiNiNgS
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

Tested
Brick,
Block or
concrete
Wall with Rw
> 41
Refer to Masonry
Wall Manufacturer
for FRL Details

cSR 531

Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

cSR 526

Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 9mm CeminSeal
Wallboard.

cSR 532

Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

Tested
Brick,
Block or
concrete
Wall with Rw
> 44
Refer to Masonry
Wall Manufacturer
for FRL Details

cSR 533

Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

cSR 527

Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 9mm CeminSeal
Wallboard.

D14

cAViTy iNfiLL (Refer to Section A)

Rw / Rw+ctr

(a) 50 GW Partition 11kg

55/42

(b) TSB2/ASB2 Polyester

53/40

ADDITIONAL WALL THICKNESS mm

71

(a) 50 GW Partition 11kg

58/45

(b) TSB2/ASB2 Polyester

56/43

ADDITIONAL WALL THICKNESS mm

84

(a) 50 GW Partition 11kg

55/42

(b) TSB2/ASB2 Polyester

53/40

ADDITIONAL WALL THICKNESS mm

67

(a) 50 GW Partition 11kg

58/45

(b) TSB2/ASB2 Polyester

56/43

ADDITIONAL WALL THICKNESS mm

71

(a) 50 GW Partition 11kg

61/48

(b) TSB2/ASB2 Polyester

59/46

ADDITIONAL WALL THICKNESS mm

84

(a) 50 GW Partition 11kg

58/45

(b) TSB2/ASB2 Polyester

56/43

ADDITIONAL WALL THICKNESS mm

67

The Red Book

masonry Wall Systems - Resilient mount/furring channel


SySTEm SPEcificATiON

TyPicAL LAyOuT (cSR 535 shown)

AcOuSTic
OPiNiON
PKA-053
NOT
Deemed
Discontinuous
Construction

Lining as per table, direct fixed to furring.


28mm furring channel at 600mm max. centres, fixed to
masonry with CSR Gyprock Resilient Mounts.
Cavity infill, as per table.
Single Brick, Block or Concrete wall with Rw as stated.
Plasterboard as per system table, direct fixed to masonry.

masonry
Wall
Requirements

SySTEm
N

cSR 534

WALL LiNiNgS
Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

Tested
Brick,
Block or
concrete
Wall with Rw
> 46
Refer to Masonry
Wall Manufacturer
for FRL Details

cSR 535

Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
2 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

cSR 528

Masonry side
1 x 13mm GYPROCK
plasterboard CD
Furring side
1 x 9mm CeminSeal
Wallboard.

The Red Book

cAViTy iNfiLL (Refer to Section A)

Rw / Rw+ctr

(a) 50 GW Partition 11kg

60/47

(b) TSB2/ASB2 Polyester

58/45

ADDITIONAL WALL THICKNESS mm

71

(a) 50 GW Partition 11kg

63/50

(b) TSB2/ASB2 Polyester

61/48

ADDITIONAL WALL THICKNESS mm

84

(a) 50 GW Partition 11kg

60/47

(b) TSB2/ASB2 Polyester

58/45

ADDITIONAL WALL THICKNESS mm

67

D15

masonry Wall Systems - cSR hebel Powerpanel


SySTEm SPEcificATiON

TyPicAL LAyOuT (hEBEL 1030/1031 shown)

AcOuSTic
TEST
OR
OPiNiON
ATf-1023
Discontinuous
Construction

Plasterboard as per table, fixed to panels.


75mm CSR Hebel Powerpanel.
30mm minimum gap with cavity infill, as per table.
75mm Hebel Powerpanel.
Plasterboard as per table, fixed to panels.

fRL
Report/Opinion

SySTEm
N

WALL LiNiNgS

cAViTy iNfiLL

(Refer to Section A)

Rw / Rw+ctr

hEBEL 1030/1031
up to
/240/240

(a) 50 GW Partition 11kg

Both sides

64/59

1 x 10mm GYPROCK
plasterboard CD.

FCO 2073

WALL THICKNESS mm

SySTEm SPEcificATiON

TyPicAL LAyOuT (hEBEL 1000/1001 shown)

200

AcOuSTic
TEST
OR
OPiNiON
2010861.1/
0505A/
R2/Vf

Plasterboard as per table, fixed to studs.


64mm steel studs at 600mm max. centres.

Discontinuous
Construction

Cavity infill, as per table.


35mm minimum gap.
75mm CSR Hebel Powerpanel.
Plasterboard as per table, fixed to panel.

fRL
Report/Opinion

SySTEm
N

WALL LiNiNgS

cAViTy iNfiLL (Refer to Section A)

Rw / Rw+ctr

hEBEL 1000/1001
up to
/180/180
FCO 2073

Both sides

(a) 75 GW Partition 11kg

1 x 13mm GYPROCK
FYRCHEK plasterboard.
WALL THICKNESS mm

D16

62/54

200

The Red Book

masonry Wall Systems - cSR hebel Powerpanel


SySTEm SPEcificATiON

TyPicAL LAyOuT (hEBEL 1006/1007 shown)

AcOuSTic
TEST
OR
OPiNiON
2010861.1/
0505A/
R2/Vf

Plasterboard as per table, fixed to furring.


Rondo N129 furring channel at 600mm max. centres
with 50mm Glasswool Partition batts 11kg.
75mm CSR Hebel Powerpanel

Discontinuous
Construction

35mm minimum gap.


64mm steel studs at 600mm max. centres with 50mm
Glasswool Partition batts 11kg.
Plasterboard as per table, fixed to studs.

fRL
Report/Opinion

SySTEm
N

WALL LiNiNgS

cAViTy iNfiLL (Refer to Section A)

Rw / Rw+ctr

hEBEL 1006/1007
up to
/180/180

Both sides

(a) Insulation as per system specification

62/51

1 x 13mm GYPROCK
FYRCHEK plasterboard

FCO 2073

WALL THICKNESS mm

SySTEm SPEcificATiON

TyPicAL LAyOuT (hEBEL 1032/1033 shown)

228

AcOuSTic
TEST
OR
OPiNiON

Plasterboard as per table, fixed to furring.


2010861.1/
0505A/
R2/Vf

Rondo N129 furring channel at 600mm max. centres


with 50mm Glasswool Partition batts 11kg.
75mm CSR Hebel Powerpanel

Discontinuous
Construction

30mm minimum gap with 50mm Glasswool Partition


batts 11kg.
75mm CSR Hebel Powerpanel
Rondo N129 furring channel at 600mm max. centres
with 50mm Glasswool Partition batts 11kg.
Plasterboard as per table, fixed to furring.

fRL
Report/Opinion

SySTEm
N

WALL LiNiNgS

cAViTy iNfiLL

(Refer to Section A)

Rw / Rw+ctr

hEBEL 1032/1033
up to
/240/240
FCO 2073

Both sides

(a) Insulation as per system specification

1 x 10mm GYPROCK
plasterboard CD.
WALL THICKNESS mm

The Red Book

64/59

256

D17

cSR hebel Low-Rise multi-Residential intertenancy Party Walls


SySTEm SPEcificATiON

AcOuSTic
OPiNiON

TyPicAL LAyOuT (hEBEL 1302)

Lining as per table, fixed to studs.

PKA-A073

Timber studs at 450mm max. centres (10mm GYPROCK


plasterboard CD) or 600mm max. centres.

Discontinuous
Construction

Cavity infill as per table.


10-20mm minimum cavity between Powerpanel and
framing.
75mm thick Hebel Powerpanel.
10-20mm minimum cavity between Powerpanel and
framing.
Cavity infill as per table.
Timber studs at 450mm max. centres (10mm GYPROCK
plasterboard CD) or 600mm max. centres.
Lining as per table, fixed to studs.

fRL
Report/Opinion

SySTEm
N

STuD DEPTh (mm)


WALL LiNiNgS

cAViTy iNfiLL (both sides)


(Refer to Section A)

hEBEL 1302
Both sides
1 x 10mm GYPROCK
plasterboard CD.

Both sides
1 x 13mm GYPROCK
plasterboard CD.

Both sides

/90/90
90/90/90

1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

WFRA 45771-3

49/38

(b) 90 Gold Batts 2.0 both sides

61/48

63/51

(c) TSB4 Polyester both sides

56/43

(d) TSB5 Polyester both sides

59/47

255

295

(a) Nil

49/38

50/39

(b) 90 Gold Batts 2.0 both sides

63/51

64/52

(c) TSB4 Polyester both sides

58/46

(d) TSB5 Polyester both sides

60/48

261

301

(a) Nil

52/41

53/42

(b) 90 Gold Batts 2.0 both sides

66/54

67/56

(c) TSB4 Polyester both sides

61/49

(d) TSB5 Polyester both sides

63/52

261

301

(a) Nil

48/37

50/39

(b) 90 Gold Batts 2.0 both sides

62/49

63/51

(c) TSB4 Polyester both sides

57/44

(d) TSB5 Polyester both sides

59/47

255

295

(a) Nil

50/39

51/40

(b) 90 Gold Batts 2.0 both sides

65/52

66/55

(c) TSB4 Polyester both sides

60/47

(d) TSB5 Polyester both sides

62/51

253

293

MINIMUM WALL THICKNESS mm

hEBEL 1305
Both sides
1 x 10mm GYPROCK
AQUACHEK
plasterboard.

MINIMUM WALL THICKNESS mm

hEBEL 1306
Both sides
1 x 9mm CeminSeal
Wallboard.

MINIMUM WALL THICKNESS mm

D18

Rw / Rw+ctr
47/36

MINIMUM WALL THICKNESS mm

hEBEL 1304

90

(a) Nil

MINIMUM WALL THICKNESS mm

hEBEL 1303

70

The Red Book

masonry Wall Systems - fRL upgrade


SySTEm SPEcificATiON

TyPicAL LAyOuT (cSR 730 shown)

AcOuSTic
TEST
OR
OPiNiON
N/A

Plasterboard lining as per table, fixed to furring channels.


Rondo furring channels or studs at 600mm maximum
centres.
Masonry wall with FRL X/Y/Z.
Rondo furring channel or studs at 600mm maximum
centres.
Plasterboard lining as per table, fixed to furring channels.

fRL
Report/Opinion

SySTEm
N

WALL LiNiNgS

ADDiTiONAL fRL

cSR 730
Both sides
1 x 16mm GYPROCK
FYRCHEK plasterboard

X+30 / Y+60 / Z+60

cSR 731
masonry
Wall

Both sides
2 x 13mm GYPROCK
FYRCHEK plasterboard.

x/y/Z

X+60 / Y+120 / Z+120

FCO 382

cSR 732
Both sides
2 x 16mm GYPROCK
FYRCHEK plasterboard.

The Red Book

X+90 / Y+180 / Z+180

D19

masonry Wall Systems - fRL upgrade


SySTEm SPEcificATiON

AcOuSTic
TEST
OR
OPiNiON

TyPicAL LAyOuT (cSR 722 shown)

N/A

Plasterboard lining as per table, fixed to furring channels.


Rondo furring channels or studs at 600mm maximum
centres.
Masonry wall with FRL X/Y/Z.

fRL
Report/Opinion

SySTEm
N

WALL LiNiNgS

ADDiTiONAL fRL
Lining on fire side

Lining on non-fire side

X+30 / Y+30 / Z+30

X+0 / Y+20 / Z+30

X+60 / Y+60 / Z+60

X+0 / Y+40 / Z+60

X+90 / Y+90 / Z+90

X+0 / Y+60 / Z+90

cSR 722
one side
1 x 16mm GYPROCK
FYRCHEK plasterboard

cSR 723
masonry
Wall

one side
2 x 13mm GYPROCK
FYRCHEK plasterboard.

x/y/Z
FCO 382

cSR 724
one side
2 x 16mm GYPROCK
FYRCHEK plasterboard.

D20

The Red Book

concrete column Encasement Systems


SySTEm SPEcificATiON

Reinforced concrete column with FRL X/-/-.

fig D2: cONcRETE cOLumN ENcASEmENT SySTEm


fiRE RATED PLASTERBOARD fixED TO fuRRiNg

Plasterboard lining as per table fixed direct to column.


OR
Rondo furring channel at 600mm maximum centres with
plasterboard lining as per table fixed to Rondo furring
channel.
fRL

SySTEm
N

FCO 1356

Fix External Angle


Bead and set all
external angles

PLASTERBOARD
LiNiNg

Steel reinforced
concrete column

cSR 795
1 x 16mm
GYPROCK
FYRCHEK
plasterboard.

x+30/ /

cSR 796
2 x 13mm
GYPROCK
FYRCHEK
plasterboard.

x+60/ /

2 x 16mm
GYPROCK
FYRCHEK
plasterboard.

cSR 798
1 x 25mm
GYPROCK
SHAFT LINER
PANEL.

x+120/ /

fig D1: cONcRETE cOLumN ENcASEmENT SySTEm


fiRE RATED PLASTERBOARD DiREcT fixED
Fix External Angle
Bead and set all
external angles

Steel reinforced
concrete column

Furring Channel
N308 or Centre
Fix Batten N333
at 600mm max.
centres

50mm
600mm max.
max.
Anchor Clip N237 fixed with metal fasteners at 100mm max.
from each end and 1200mm max. centres along column

fig D3: cONcRETE cOLumN ENcASEmENT SySTEm


fiRE RATED PLASTERBOARD fixED TO fuRRiNg

cSR 797

x+120/ /

GYPROCK
FYRCHEK
plasterboard fixed
at 200mm
maximum centres
to all framing

Direct fasten
each layer of
GYPROCK
FYRCHEK
plasterboard with
Tapcon 10g
screws (or
equivalent) at 400
x 400mm max.
horizontal and
vertical centres

Track cut and fixed to


furring channels at top
and bottom of column

GYPROCK FYRCHEK fixed


to furring channel at 200mm
max. centres
Anchor Clips
N237 at
1200mm
maximum
vertical centres
and N308
Furring
Channel at
600mm
maximum
horizontal
centres or
Centre Fix
Batten N333
directly fixed at
600mm
maximum
horizontal
centres
Offset Butt
Joints in
consecutive
layers by
300mm
minimum
Fasten at
butt joints with
laminating
screws at
200mm max
centres

Screw fix each layer


at 200mm
maximum centres
to steel framing

200mm max.

Apply
External
Angle
Bead to
all
corners
and set
Note: Butt joints in single layer systems to be
backed by furring channel or nogging

75mm
max.

400mm max.

The Red Book

D21

fig D4: iNSTALLATiON DETAiL mASONRy WALL (ExcEPT AAc) VERTicAL ShEETiNg ADhESiVE fixiNg
For additional information, refer to GYP547, Gyprock Residential Installation Guide
Adhesive daubs
50mm max.
from sheet
edge

Adhesive daubs
at 230mm max.
centres

Adhesive daubs
100mm max from
top edge of sheet

Adhesive daubs
50mm max.
from sheet
edge

NON-fiRE RATED
fiRE RATED
fixing Specifications
Adhesive

Adhesive daubs
at 460mm max.
centres
Adhesive
daubs
at 460mm
max.
centres

GYPROCK
Plasterboard

Adhesive daubs
100mm max from
bottom edge of
sheet

Refer to Section A

Location

fixing & Spacing

Field

Adhesive at 460mm
max. centres
beginning 100mm
max. from top and
bottom sheet edges
and 50mm max.
from recessed sheet
edges

Butt Joints,
Corners &
Openings

Adhesive at 460mm
max. centres 50mm
max. from sheet
edges

Daubs of GYPROCK Masonry Adhesive.


6mm min. gap

fig D5: iNSTALLATiON DETAiL mASONRy WALL WiTh fuRRiNg chANNEL


hORiZONTAL ShEETiNg ScREW fixiNg
For additional information, refer to GYP544, Gyprock Steel Frame Wall Systems Installation Guide
Rondo Track or
Angle fixed to ceiling
frame

NON-fiRE RATED
fiRE RATED

One or two layers


of GYPROCK
FYRCHEK
Plasterboard to
each side of wall

300mm min.

300mm
max.

CSR Gyprock
Resilient Mounts or
Furring Anchor Clips
at 1200mm max.
from tracks and
1200mm max.
centres between

600mm
min

600mm
min

600mm
max.
300mm
max.

Rondo Furring
Channel at 600mm
maximum
horizontal centres
Caulk all perimeter
gaps with CSR
Gyprock Fire Mastic
to achieve stated fire
rated and acoustic
performance
Rondo Track or
Angle fixed to floor

D22

fixing Specifications
Screws

Refer to Section A

1st Layer

fixing & Spacing

Edges &
Field

Screws at 600mm
max. centres

2nd Layer

fixing & Spacing

Field

Screws at 300mm
max. centres

Recessed
Edges

Screw at
each furring

Butt
Joints

Screws at
200mm max. centres

Angles &
Openings

Screws at
300mm max. centres

NOTE:
Single layer systems using fire
rated or non-fire rated Gyprock
plasterboard are fixed to the same
specifications as detailed for the 2nd
layer.

200mm
max.

Fasteners at 10 to 16mm
from sheet edges

The Red Book

fig D6: iNSTALLATiON DETAiL hEBEL AAc WALL VERTicAL ShEETiNg ScREW fixiNg
For additional information, refer to CSR Hebel Design Guide Acoustic Wall Systems

NON-fiRE RATED
fiRE RATED

10-16mm
max.

fixing Specifications

GYPROCK
Plasterboard

Fixings

50mm x 10g bugle


head screws

Location

fixing & Spacing

Field, Butt
Joints &
Edges

Screws at 600mm
max. horizontal
centres x 300mm
max. vertical centres

CSR Hebel AAC Panel


300mm
max.

6mm min.
gap
600 mm
max.

fig D7: iNSTALLATiON DETAiL hEBEL AAc WALL hORiZONTAL ShEETiNg ScREW fixiNg
For additional information, refer to CSR Hebel Design Guide Acoustic Wall Systems

NON-fiRE RATED
fiRE RATED
fixing Specifications
CSR Hebel AAC Panel

Fixings

50mm x 10g bugle


head screws

Location

fixing & Spacing

Field, Butt
Joints &
Edges

Screws at 600mm
max. horizontal
centres x 300mm
max. vertical centres

CSR Hebel AAC Panel

GYPROCK
Plasterboard
300mm
max.

6mm min.
gap

10-16mm
min. from
each edge

The Red Book

600mm
max.

D23

Notes

D24

The Red Book

Section E
Ceiling Systems

Contents
Introduction

E2

Design Considerations

E2 E3

Installation

E4

Components

E4 E5

System Specifications







loor/Ceiling Systems
F
(Timber Flooring)

E6 E15

loor/Ceiling Systems
F
(Concrete Flooring)

E16 E23

oof/Ceiling Systems
R
(Pitched Roofing)

E24 E29

oof/Ceiling Systems
R
(Steel Sheet Roofing)

E30 E33

eiling Systems
C
Fire Rated from Above

E34

eiling Systems Fire Rated


C
from Above and/or Below

E35

ebel PowerFloor Fire Rated


H
from Above and/or Below

E36

Acoustic Tile Ceiling Systems

E37 E38

System Installation Details

The Red Book

E39 E43

E1

Introduction
CSR has developed a wide range of floor/ceiling and
roof/ceiling systems to meet specific fire and acoustic
requirements. The systems include ratings for sound
transmission, sound impact and sound absorption, for fire
resistance up to FRL 120/120/120, and for up to 60 minutes
Resistance to Incipient Spread of Fire (RISF).
Generally, the fire resistance of floor and roof/ceiling systems
is assessed from below, in accordance with the standard
fire test of AS1530.4. This is the requirement of the BCA
where lightweight construction is used for compartmentation
and separation. Some elements such as fire-isolated
passageways are required to have an FRL when tested from
outside. A number of ceiling systems are available that offer
fire resistance from above to meet this requirement.
CSR ceiling systems use various fixing techniques for the
attachment of linings. These include:
a) Direct fixing to timber and steel joists or truss bottom
chords.
b) Screw fixing to steel furring channels.
c) Screw fixing to resilient or resiliently mounted furring
channels.
d) Screw fixing to suspended concealed metal grid.
e) Lay-in tiles in suspended exposed metal grid or Fricker
Easy Access System.

Design
Considerations
Structural
All floor, roof and ceiling framing must be designed for
the applied loads. Guidance for the selection of Rondo
suspension and grid components is given in brochure
NGYP570 Gyprock Ceiling Systems Installation Guide.
For other elements, refer to the appropriate design standards
or handbooks, or contact the manufacturer for design
information.
CSR recommends a minimum design pressure of 0.25kPa
(downward) for the ceiling framing. Other wind pressures may
be applicable; the designer should refer to AS/NZS1170.
Wind loads on external ceilings can be similar to those on
adjacent walls. Pressures can be positive or negative and
the lining, grid and structure should be designed to resist
the loads. Internal suspension components, even with down
struts, may not be suitable.

loads greater than 0.5kPa and for some FRLs.


CSR Ceiling systems have been designed for timber or steel
framing as noted in the system specification. Timber framing
shall be solid timber or engineered floor joist such as LVL
Glulam, plyweb joists, or trusses made from solid timber
framing must be designed in accordance with AS1720.1.
or AS1684
Steel framing for direct fixing of linings shall have maximum
base metal thickness (BMT) 1.6mm. Framing may be trusses,
top hats, C sections, furring channels, or similar members.
in all cases they should be designed in accordance with
AS4600.
For steel components in external environments, in heavy
industrial areas or coastal areas, additional coatings may be
required. Refer to AS/NZS2785 for guidance
Direct-Fix Framing Systems
Ceiling linings may be fixed directly to primary timber or steel
framing, or to secondary members such as furring channels
and battens.
Timber members to which plasterboard will be fixed
must comply with AS1684 Residential Timber-Framed
Construction, or be designed in accordance with AS1720.1
Timber Structures: Design Methods.
Steel framing to which plasterboard will be fixed must comply
with AS/NZS4600, Cold Formed Steel Structures.
Suspended Ceiling Systems
Ceiling suspension systems must be designed to
AS/NZS2785 Suspended Ceilings Design and Installation.
Ceilings in this manual are not trafficable. Trafficable systems
shall be designed in accordance with AS1657 Fixed
Platforms, Walkways, Stairways and Ladders.
Ceilings Rated from Above
Ceiling systems with plasterboard linings on top of joists
are not trafficable or intended to be used for storage. The
joists should be designed for all imposed loads including
construction loads where fixing of sheets is required from
above. Appropriate barriers and signage should be installed
to prevent access.

Fire Performance
Gyprock fire rated ceiling systems have been designed with
fire protection that protects the framing. This means that no
consideration of steel or timber framing design need be given
for the fire rating.

The maximum spacing of ceiling framing is 600mm. Closer


spacing may be required for some lining materials, for design

E2

The Red Book

To protect structural beams that are entirely within the ceiling


space, the structural adequacy component of the ceiling
system FRL must be at least equivalent to that required by
the structural member. For example, a ceiling system with
FRL 90/90/90 provides FRL 90/-/- for a steel beam within
the ceiling. Systems are available for beams that are not
entirely enclosed.
Framing and Lining
Plasterboard must be screw fixed only, adhesive is not
permitted. Joints in the outer layer of all systems must be
set with Gyprock paper tape. As a minimum, a single coat
finish may be used.
For general installation information refer to FIG E3 to E10.
Detailed fixing information is provided in brochures: Gyprock
Ceiling Systems Installation Guide NGYP570, CSR Gyprock
Shaft Systems NGYP546, Cemintel Ceiling Systems
NFC129, Cemintel ExpressWall Facade System NFC126
and CSR Hebel PowerFloor Design Guide, NHBL751-LRPF.
Ceiling systems are generally shown in a horizontal orientation.
The system FRL and RISF will not be reduced if ceilings are
built on a rake. The support framing, including lateral bracing,
must be designed considering the slope of the ceiling.
Alternative support framing members may be used where
timber joists are shown without reducing the system FRL
and RISF. These members include, but are not limited to,
steel, composite steel/timber joists, laminated timber joists,
and trussed or plywood web joists.
System specifications for minimum cavity depths and floor
surface finishes relate to acoustic performance only.
Roof Materials
Roof/ceiling systems may include options for roof tiles
and steel roof sheeting. Where steel sheeting is used, the
specified Anticon insulation must be installed to achieve
the stated FRL.
Caulking
To attain the specified fire rating, all perimeter gaps and
penetrations must be carefully and completely filled with
appropriate caulking material. In fire rated systems, to
attain the stated fire rating use CSR Gyprock Fire Mastic
or other tested fire rated material of equivalent or better
performance. Details for fire sealing of penetrations is given
in Section Z.
Vermiculite plaster is not to be used as a general purpose
fire rated caulking. Its use is specified in some wall/ceiling
junctions; refer to Gyprock Ceiling Systems Installation
Guide NGYP570. Vermiculite plaster has no capacity to
accommodate building movement.

The Red Book

Acoustic Performance
Sound Transmission
Sound flanking, the effectiveness of workmanship and
caulking, the presence and treatment of penetrations, and
the inclusion of structural elements and bridging items, may
affect the acoustic performance of ceiling systems. Refer to
Section A for detailed information.
Alternative structural framing systems including steel, and
composite steel/timber joists, laminated timber joists, and
trussed or plywood web joists may be used without reducing
the system rating. The stated or implied minimum cavity
depth must also be maintained.
For effective control of sound in the flanking path of a floor
or roof space, acoustically rated walls should continue to
the underside of the floor or roof above. Alternatively, select
a detail from section G equivalent to the required Rw or
Rw + Ctr performance of the wall.
Ceilings systems beneath concrete slabs are unlikely to
achieve greater than DnT,w 65 due to the number of flanking
paths and variations in building construction.
Rw and Rw+Ctr values published are estimated performance
in a laboratory, and the higher values may be beyond the
limits of some laboratories to measure.
In non-fire rated systems, to attain the stated sound
transmission performance, use a tested acoustic sealant.
All penetrations should be treated to maintain the acoustic
integrity of the system.
The values given for roofs assume that there are no vents,
skylights or similar penetrations, and that the eaves are not
vented. Note that the effect of such penetrations will be lower
for ceilings lined with multiple layers of plasterboard.
Sound impact performance is stated as Ln,w + CI. Note that
a lower value of Ln,w + CI has a higher impact performance.
Values refer to expected laboratory performance, and
assume relatively stiff floor joists. Installations with joists of
lower stiffness may reduce the impact performance.
Floors finished with carpet and underlay achieve better
impact performance than those with hard surfaces such as
floorboards and tiles. If carpet is subsequently removed (from
a system that uses it in its performance value), the floor may
no longer meet the BCA impact requirements.
Sound Absorption
Gyprock Perforated Plasterboard, Ecophon, Fricker and
USG ceiling products have sound absorption qualities. These
products may be used to influence the reverberation time of
a room in order to improve the sound quality.
Product performance is expressed as NRC, and values vary
from 0 (total reflection) to 1.00 (total absorption). NRC values
can be found in system CSR 890

E3

Plasterboard & Fibre Cement Fixing


Ceilings may be built to achieve a particular Level of Finish
as defined in AS/NZS2589.1. The Level of Finish specified
can have requirements for frame alignment, jointing and back
blocking methods.
Lining sheets must be installed with the long edge at right
angles to the direction of the framing to which they are fixed.
Refer to FIG E3 to E10 for general fixing information using
fastener and fastener/adhesive fixing methods. Detailed fixing
information is provided in Gyprock Residential Installation
Guide, NGYP547, Cemintel Ceiling Systems NFC129 and
Gyprock Ceiling Systems Installation Guide, NGYP570.
Fire rated systems MUST NOT rely on adhesive fixing of
linings.

Lining & Fixing Materials


Refer to Section A of this manual for detailed information
on Gyprock plasterboard products, Cemintel products,
adhesive and fastener specifications.
Details of the performance and range of acoustic ceiling tiles
can be found in specific product manuals. Please contact
CSR Fricker Comprador for more information.

Steel Grid & Suspension


Components
CSR recommends components manufactured by CSR
Fricker Comprador and Rondo Building Services Pty Ltd.
Additional information on the steel components can be
obtained from CSR Fricker, telephone 1300 374 253, or
Rondo 1300 367 663.

GYPROCK ReSiLienT MOunT

Jointing

24mm
4.5mm

Gyprock
Resilient
Mount

Refer to the Gyprock Residential Installation Guide,


NGYP547 for detailed jointing and finishing of ceilings
lined with plasterboard. In multi-layer systems, jointing
and finishing is required on the visible outer layer only. As
a minimum, one base coat with paper tape may be used.

20mm

For detailed information on junctions with walls, access


hatches, light fixtures, control joints and penetrations, refer
to Section Z of this manual.

Components

Furring Channel
N129 or N308

Expressed joints are recommended for ceilings lined with


Cemintel products. Refer to Cemintel Ceiling Systems
NFC129 for more information.

40mm (N129)
28mm (N308)

Installation

GYPROCK Plasterboard

Control Joints
Control joints are used to reduce the possibility of cracks
forming from structural movement, thermal and moisture
movement and the like. Locations for joints should be chosen
by the designer with regard to building shape, structural
breaks, changes of substrate, and joint appearance.

Top Cross Rail

Ceiling systems with plasterboard linings must have control


joints at 12m maximum spacing in both directions. Ceilings
lined with CeminSeal Wallboard should have joints at 3.6m
in most cases. For additional information, refer to Cemintel
Ceiling Systems NFC129.

Gyprock
Resilient
Mount

NOTE: For fire rated systems with single layer lining fixed
direct to joists, no control joint detail is available. Use a
double layer system or furring channels where control joints
are required.

Suspended Ceilings
For detailed information on installation and maintenance of
suspension systems, contact CSR Fricker Comprador on
1300 374 253.

E4

Resilient Mount to
Top Cross Rail Clip
Gyprock Screw

Furring Channel

Other
Sarking with mass at least 350g/m2 is specified in some
roof/ceiling systems to achieve the acoustic value. Suitable
products are Bradford Thermofoil 733 and Thermotuff SS.

The Red Book

FiG e1: PeRFORATiOn PATTeRn.

FiG e2: GYPROCK PeRFORATeD


PLASTeRBOARD SHeeT 8.2% OPen AReA

1200mm

80mm

1040mm
440mm

160mm

1200mm

3600mm

440mm

Overall 3600mm

TABLe e1: MAXiMuM SPAn OF PLASTeRBOARD/WALLBOARD in CeiLinG APPLiCATiOnS


Maximum Spacing of Framing Members

GYPROCK/CEMINTEL Product

General Applications

Areas of High Humidity

Thickness

(mm)

(mm)

6.5mm Flexible Plasterboard used in two layers

350

NA

10mm GYPROCK Plasterboard CD

450

NA

6mm CeminSeal Wallboard

450

450

10mm All types of plasterboard except CD

600

450

600

450

13mm plasterboard all types except Perforated


9mm CeminSeal Wallboard
13mm Perforated Sheet

600

NA

16mm FYRCHEK

600

450

NOTE: NA = Not Applicable

TABLe e2: MAXiMuM SPAnS FOR MeTAL BATTen/FuRRinG CHAnneL uSeD in CeiLinGS

Gyprock Plasterboard
Layers x Thickness

N581*

N308*

N129*

Resilient Furring

Furring Channel

Furring Channel

Spacing of Furring

Spacing of Furring

450

600

600

600

450

600

Spacing of Furring
450

600

Maximum Permissible Spans for Metal Batten/Furring


1 x 10mm all products

1000

900

1550

1400

except CD and SUPERCHEK


1 x 10mm Gyprock CD

600

1000

1550

1 x 10mm SUPERCHEK

600

600

1100

1000

1550

1400

1 x 16mm FYRCHEK

600

600

1100

1050

1550

1400

2 x 13/16mm FYRCHEK

600

600

1100

900

1400

1300

900

800

1300

1200

1 x 13mm all products

3 x 16 FYRCHEK

NOTE: Furring to be continuous over 2 or more spans. Dead load deflection Span360. * Includes Internal UDL of 0.25kPa.

The Red Book

E5

Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 803a shown)

PKA056

Floor finished bare or with carpet and underlay, as per


system table.
1 x 19mm or 22mm particleboard, or timber flooring of at
least 15kg/m2.
Timber or steel joists at 600mm maximum centres.
Minimum 190mm cavity depth.
Cavity infill as per system table.
Ceiling lining as per system table, direct fixed to framing.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

40/34

80-85

60-65

(b) 90 Gold Batts 2.0

43/36

80-85

60-62

(c) 75 Soundscreen 2.0

43/36

80-85

60-62

(a) Nil

39/32

60 65

(b) 90 Gold Batts 2.0

42/34

60 65

(c) 75 Soundscreen 2.0

42/34

60 65

(a) Nil

37/30

60 65

(b) 90 Gold Batts 2.0

40/32

60 65

(c) 75 Soundscreen 2.0

40/32

60 65

(a) Nil

43/37

55 60

(b) 90 Gold Batts 2.0

46/39

80 85

55 60

(c) 75 Soundscreen 2.0

46/39

80 85

55 60

CAViTY inFiLL
(Refer to Section A)

CSR 799
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 801
1 x 13mm GYPROCK
Plasterboard CD.

//

CSR 803
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

//

CSR 804

//

E6

2 x 10mm GYPROCK
SUPERCHEK.

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 808a shown)

PKA056

Floor finished bare or with carpet and underlay, as per


system table.
1 x 19mm or 22mm particleboard, or timber flooring of at
least 15kg/m2.
Timber or steel joists at 600mm maximum centres (except
where noted in system table).
Minimum 190mm cavity depth.
Cavity infill as per system table.
Ceiling lining as per system table, direct fixed to framing.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

40/34

55 60

(b) 90 Gold Batts 2.0

43/36

55 60

(c) 75 Soundscreen 2.0

43/36

55 60

(a) Nil

40/34

55 60

(b) 90 Gold Batts 2.0

43/36

55 60

(c) 75 Soundscreen 2.0

43/36

55 60

(a) Nil

43/37

55 60

(b) 90 Gold Batts 2.0

46/39

80 85

55 60

(c) 75 Soundscreen 2.0

46/39

80 85

55 60

(a) Nil

43/37

55 60

(b) 90 Gold Batts 2.0

46/39

80 85

55 60

(c) 75 Soundscreen 2.0

46/39

80 85

55 60

(a) Nil

42/36

55 60

(b) 90 Gold Batts 2.0

45/38

80 85

55 60

(c) 75 Soundscreen 2.0

45/38

80 85

55 60

(a) Nil

45/39

80 85

50 55

(b) 90 Gold Batts 2.0

48/41

80 85

50 55

(c) 75 Soundscreen 2.0

48/41

80 85

50 55

CAViTY inFiLL
(Refer to Section A)

CSR 805
1 x 13mm GYPROCK
FYRCHEK
Plasterboard.

30/30/30
EWFA 26162

NOTE: Framing at
450mm max. centres.

CSR 820
1 x 16mm GYPROCK
FYRCHEK
Plasterboard.

30/30/30
EWFA 26162

CSR 806
60/60/60

2 x 13mm GYPROCK
FYRCHEK
Plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 809
60/60/60
+RISF 60
minutes
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 807
90/90/90

2 x 16mm GYPROCK
FYRCHEK
Plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 808
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
Plasterboard.

E7

Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 811a shown)

PKA056

Floor finished bare or with carpet and underlay, as per


system table.
1 x 19mm or 22mm particleboard, or timber flooring of at
least 15kg/m2.
Timber or steel joists.
Minimum 205mm cavity depth.
RONDO Furring Channels.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

39/32

60 65

(b) 90 Gold Batts 2.0

44/35

60 65

(c) 75 Soundscreen 2.0

44/35

60 65

(a) Nil

39/32

80-85

60-65

(b) 90 Gold Batts 2.0

44/37

75-80

60-62

(c) 75 Soundscreen 2.0

44/37

75-80

60-62

(a) Nil

42/36

80-85

60-62

(b) 90 Gold Batts 2.0

47/41

75-80

55-60

(c) 75 Soundscreen 2.0

47/41

75-80

55-60

(a) Nil

40/34

80-85

60-62

(b) 90 Gold Batts 2.0

45/39

75-80

55-60

(c) 75 Soundscreen 2.0

45/39

75-80

55-60

(a) Nil

41/34

55 60

(b) 90 Gold Batts 2.0

46/37

80 85

55 60

(c) 75 Soundscreen 2.0

46/37

80 85

55 60

(a) Nil

45/39

75-80

55-60

(b) 90 Gold Batts 2.0

50/44

70-75

50-55

(c) 75 Soundscreen 2.0

50/44

70-75

50-55

CAViTY inFiLL
(Refer to Section A)

CSR 810
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

//

CSR 886
1 x 10mm GYPROCK
Plasterboard CD.

//

CSR 885
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 811
1 x 13mm GYPROCK
Plasterboard CD.

//

CSR 812
1 x 6mm CeminSeal
Wallboard.

//

CSR 888

//

E8

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 815a shown)

Floor finished bare or with carpet and underlay, as per


system table.

PKA056

1 x 19mm or 22mm particleboard, or timber flooring of at


least 15kg/m2.
Timber or steel joists.
Minimum 205mm cavity depth.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.
FRL
Report/Opinion

SYSTeM
n

CSR 815
30/30/30

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.

EWFA 26162

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

42/36

55 60

(b) 90 Gold Batts 2.0

47/39

80 85

55 60

(c) 75 Soundscreen 2.0

47/39

80 85

55 60

(a) Nil

42/36

55 60

(b) 90 Gold Batts 2.0

47/39

80 85

55 60

(c) 75 Soundscreen 2.0

47/39

80 85

55 60

(a) Nil

45/39

80 85

55 60

(b) 90 Gold Batts 2.0

50/42

75 80

55 60

(c) 75 Soundscreen 2.0

50/42

75 80

55 60

(a) Nil

45/39

80 85

55 60

(b) 90 Gold Batts 2.0

50/42

75 80

55 60

(c) 75 Soundscreen 2.0

50/42

75 80

55 60

(a) Nil

44/38

80 85

55 60

(b) 90 Gold Batts 2.0

49/41

80 85

55 60

(c) 75 Soundscreen 2.0

49/41

80 85

55 60

(a) Nil

47/41

80 85

55 60

(b) 90 Gold Batts 2.0

52/44

75 80

55 60

(c) 75 Soundscreen 2.0

52/44

75 80

55 60

CAViTY inFiLL
(Refer to Section A)

CSR 816
1 x 16mm GYPROCK
FYRCHEK
plasterboard.

30/30/30
EWFA 26162

CSR 814
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 819
60/60/60
+RISF 60
minutes

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

EWFA 26162

CSR 817
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 818
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E9

Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 823a shown)

Floor finished bare or with carpet and underlay, as per


system table.

PKA056

1 x 19mm or 22mm particleboard, or timber flooring of at


least 15kg/m2.
Timber or steel joists.
Minimum 230mm cavity depth.
RONDO Furring Channel clipped to Gyprock
Resilient Mounts
OR
RONDO Resilient Furring Channel (N581).
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.
FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

46/37

75 80

55 60

(b) 90 Gold Batts 2.0

55/46

65 70

50 55

(c) 75 Soundscreen 2.0

54/44

65 70

50 55

(a) Nil

46/40

75 80

55 60

(b) 90 Gold Batts 2.0

55/47

65 70

50 55

(c) 75 Soundscreen 2.0

54/45

65 70

50 55

(a) Nil

49/43

75 80

55 60

(b) 90 Gold Batts 2.0

58/50

65 70

50 55

(c) 75 Soundscreen 2.0

57/48

65 70

50 55

CAViTY inFiLL
(Refer to Section A)

CSR 821
1 x 13mm GYPROCK
Plasterboard CD.

//

CSR 823
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 824

//

E10

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 828a shown)

Floor finished bare or with carpet and underlay, as per


system table.

PKA056

1 x 19mm or 22mm particleboard, or timber flooring of at


least 15kg/m2.
Timber or steel joists.
Minimum 230mm cavity depth.
RONDO Furring Channel clipped to Gyprock
Resilient Mounts.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.
FRL
Report/Opinion

SYSTeM
n

CSR 825
30/30/30

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.

EWFA 26162

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

47/41

75 80

55 60

(b) 90 Gold Batts 2.0

56/48

65 70

50 55

(c) 75 Soundscreen 2.0

55/46

65 70

50 55

(a) Nil

46/40

75 80

55 60

(b) 90 Gold Batts 2.0

55/47

65 70

50 55

(c) 75 Soundscreen 2.0

54/45

70 75

50 55

(a) Nil

50/44

70 75

50 55

(b) 90 Gold Batts 2.0

59/51

60 62

45 50

(c) 75 Soundscreen 2.0

58/48

60 62

45 50

(a) Nil

50/44

70 75

50 55

(b) 90 Gold Batts 2.0

59/51

60 65

45 50

(c) 75 Soundscreen 2.0

58/48

60 65

45 50

(a) Nil

50/44

70 75

50 55

(b) 90 Gold Batts 2.0

59/51

60 62

45 50

(c) 75 Soundscreen 2.0

58/48

60 62

45 50

(a) Nil

49/43

70-75

35-40

(b) 90 Gold Batts 2.0

59/53

60-62

35-40

(c) 75 Soundscreen 2.0

59/52

60-62

35-40

CAViTY inFiLL
(Refer to Section A)

CSR 826
1 x 16mm GYPROCK
FYRCHEK
plasterboard.

30/30/30
EWFA 26162

CSR 829
60/60/60
+RISF 60
minutes

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

EWFA 26162

CSR 822
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 827
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 828
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E11

Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 833a shown)

PKA056

Floor finished bare or with carpet and underlay, as per


system table.
1 x 19mm or 22mm particleboard, or timber flooring of at
least 15kg/m2.
Timber or steel joists.
Minimum 340mm cavity depth.
RONDO Suspended Ceiling System.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

46/39

80 85

60 65

(b) 90 Gold Batts 2.0

52/45

75 80

55 60

(c) 75 Soundscreen 2.0

52/45

75 80

55 60

(a) Nil

46/40

80 85

60 65

(b) 90 Gold Batts 2.0

52/46

75 80

55 60

(c) 75 Soundscreen 2.0

52/46

75 80

55 60

(a) Nil

48/42

80 85

60 65

(b) 90 Gold Batts 2.0

54/48

75 80

55 60

(c) 75 Soundscreen 2.0

54/48

75 80

55 60

(d) 165 GW Partition

56/50

70 75

55 60

(a) Nil

49/43

80 85

60 65

(b) 90 Gold Batts 2.0

54/49

75 80

55 60

(c) 75 Soundscreen 2.0

54/49

75 80

55 60

(d) 165 GW Partition

56/51

70 75

55 60

CAViTY inFiLL
(Refer to Section A)

CSR 831

1 x 13mm GYPROCK
Plasterboard CD.

//

CSR 833

1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 832

2 x 13mm GYPROCK
Plasterboard CD.

//

CSR 834

//

E12

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 837a shown)

Floor finished bare or with carpet and underlay, as per


system table.

PKA056

1 x 19mm or 22mm particleboard, or timber flooring of at


least 15kg/m2.
Timber or steel joists.
Minimum 340mm cavity depth.
RONDO Suspended Ceiling System.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.
FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

46/40

80 85

60 65

(b) 90 Gold Batts 2.0

52/46

75 80

55 60

(c) 75 Soundscreen 2.0

52/46

75 80

55 60

(a) Nil

49/43

80 - 85

55 - 60

(b) 90 Gold Batts 2.0

55/49

70 - 75

50 - 55

(c) 75 Soundscreen 2.0

55/49

70 - 75

50 - 55

(a) Nil

50/44

75 80

55 60

(b) 90 Gold Batts 2.0

56/50

70 75

50 55

(c) 75 Soundscreen 2.0

56/50

70 75

50 55

(d) 165 GW Partition

58/52

70 75

50 55

(a) Nil

49/43

80 85

55 60

(b) 90 Gold Batts 2.0

55/49

70 75

50 55

(c) 75 Soundscreen 2.0

55/49

70 75

50 55

(d) 165 GW Partition

57/51

70 75

50 55

(a) Nil

52/46

75 80

55 60

(b) 90 Gold Batts 2.0

58/52

70 75

50 55

(c) 75 Soundscreen 2.0

58/52

70 75

50 55

(d) 165 GW Partition

60/54

65 70

50 55

CAViTY inFiLL
(Refer to Section A)

CSR 835
1 x 13mm GYPROCK
FYRCHEK
plasterboard.

30/30/30
EWFA 26162

Furring channel at
450mm maximum
centres.

CSR 836
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 839
1 x 13mm GYPROCK
FYRCHEK
plasterboard.

60/60/60
+RISF 60
minutes
EWFA 26162

1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 837
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 838
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E13

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 841a shown)

Floor finished bare or with carpet and underlay, as per


system table.

PKA056

1 x 19mm or 22mm particleboard, or timber flooring of at


least 15kg/m2.
Timber or steel joists.
Minimum 340mm cavity depth.
RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.
FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

48/41

75 80

55 60

(b) 90 Gold Batts 2.0

54/47

70 75

50 55

(c) 75 Soundscreen 2.0

54/47

70 75

50 55

(d) 165 GW Partition

56/49

65 70

50 55

(a) Nil

48/42

75 80

55 60

(b) 90 Gold Batts 2.0

54/48

70 75

50 55

(c) 75 Soundscreen 2.0

54/48

70 75

50 55

(d) 165 GW Partition

56/50

65 70

50 55

(a) Nil

51/45

70 - 75

50 - 55

(b) 90 Gold Batts 2.0

57/51

60 - 62

45 - 50

(c) 75 Soundscreen 2.0

57/51

60 - 62

45 - 50

CAViTY inFiLL
(Refer to Section A)

CSR 841

1 x 13mm GYPROCK
Plasterboard CD.

//

CSR 845
1 x 13mm GYPROCK
FYRCHEK
plasterboard.

30/30/30
EWFA 26162

Furring channels at
450mm maximum
centres.

CSR 846
60/60/60
+RISF 30
minutes
EWFA 26162

E14

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 847a shown)

Floor finished bare or with carpet and underlay, as per


system table.

PKA056

1 x 19mm or 22mm particleboard, or timber flooring of at


least 15kg/m2.
Timber or steel joists.
Minimum 340mm cavity depth.
RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.
FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

52/46

70 75

50 55

(b) 90 Gold Batts 2.0

58/52

60 62

45 50

(c) 75 Soundscreen 2.0

58/52

60 62

45 50

(d) 165 GW Partition

60/54

60 62

40 45

(a) Nil

51/45

70 75

50 55

(b) 90 Gold Batts 2.0

57/51

60 62

45 50

(c) 75 Soundscreen 2.0

57/51

60 62

45 50

(d) 165 GW Partition

59/53

60 62

45 50

(a) Nil

54/48

70 75

45 50

(b) 90 Gold Batts 2.0

60/54

60 62

40 45

(c) 75 Soundscreen 2.0

60/54

60 62

40 45

(d) 165 GW Partition

62/56

60 62

40 45

CAViTY inFiLL
(Refer to Section A)

CSR 849
1 x 13mm GYPROCK
FYRCHEK
plasterboard.

60/60/60
+RISF 60
minutes
EWFA 26162

1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 847
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 848
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E15

Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 258a shown)

PKA056

150mm concrete slab.


RONDO furring channel.
Cavity infill as per system table in 45mm cavity.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

56/46

70-75

35-40

(b) 50 GW Partition 11kg

60/50

65-70

35-40

(c) TSB3/ASB3 Polyester

59/49

65-70

35-40

(a) Nil

57/47

70-75

35-40

(b) 50 GW Partition 11kg

61/53

65-70

35-40

(c) TSB3/ASB3 Polyester

60/52

65-70

35-40

(a) Nil

56/46

70-75

35-40

(b) 50 GW Partition 11kg

60/50

65-70

35-40

(c) TSB3/ASB3 Polyester

59/49

65-70

35-40

(a) Nil

58/49

65-70

35-40

(b) 50 GW Partition 11kg

62/54

65-70

35-40

(c) TSB3/ASB3 Polyester

61/53

65-70

35-40

(a) Nil

59/50

65-70

35-40

(b) 50 GW Partition 11kg

64/56

60-65

35-40

(c) TSB3/ASB3 Polyester

63/55

60-65

35-40

(a) Nil

60/52

65-70

35-40

(b) 50 GW Partition 11kg

65/57

60-65

35-40

(c) TSB3/ASB3 Polyester

64/56

60-65

35-40

CAViTY inFiLL
(Refer to Section A)

CSR 257
Refer to
AS3600

1 x 10mm GYPROCK
Plasterboard CD.

CSR 258
Refer to
AS3600

1 x 13mm GYPROCK
Plasterboard CD.

CSR 259
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

Refer to
AS3600

CSR 260
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

Refer to
AS3600

CSR 261
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

Refer to
AS3600

CSR 262
Refer to
AS3600

E16

2 x 10mm GYPROCK
SUPERCHEK.

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 265a shown)

PKA056

150mm concrete slab.


RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table in 45mm cavity.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CSR 263
30/30/30
EWFA 26162

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

58/49

65-70

35-40

(b) 50 GW Partition 11kg

63/55

65-70

35-40

(c) TSB3/ASB3 Polyester

62/54

65-70

35-40

(a) Nil

59/50

65-70

35-40

(b) 50 GW Partition 11kg

62/54

60-65

40-45

(c) TSB3/ASB3 Polyester

61/53

60-65

40-45

(a) Nil

61/53

65-70

35-40

(b) 50 GW Partition 11kg

66/58

60-65

35-40

(c) TSB3/ASB3 Polyester

65/57

60-65

35-40

(a) Nil

62/54

65-70

35-40

(b) 50 GW Partition 11kg

66/58

60-65

35-40

(c) TSB3/ASB3 Polyester

65/57

60-65

35-40

(a) Nil

63/56

65-70

35-40

(b) 50 GW Partition 11kg

68/61

60-65

35-40

(c) TSB3/ASB3 Polyester

67/60

60-65

35-40

CAViTY inFiLL
(Refer to Section A)

CSR 264
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 265
60/60/60
+RISF 60
minutes
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 266
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 267
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E17

Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 339a shown)

PKA056

150mm concrete slab.


Gyprock Resilient Mounts direct fixed to concrete slab
at 600 x 1200mm maximum centres.
RONDO furring channel.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

57/47

70-75

40-45

(b) 50 GW Partition 11kg

61/51

65-70

40-45

(c) TSB3/ASB3 Polyester

60/50

65-70

40-45

(a) Nil

58/48

65-70

40-45

(b) 50 GW Partition 11kg

62/54

60-62

40-45

(c) TSB3/ASB3 Polyester

61/53

60-62

40-45

(a) Nil

57/47

70-75

40-45

(b) 50 GW Partition 11kg

61/51

65-70

40-45

(c) TSB3/ASB3 Polyester

60/50

65-70

40-45

(a) Nil

59/50

62-66

40-45

(b) 50 GW Partition 11kg

63/55

60-62

40-45

(c) TSB3/ASB3 Polyester

62/54

60-62

40-45

(a) Nil

60/51

62-66

40-45

(b) 50 GW Partition 11kg

65/56

60-62

40-45

(c) TSB3/ASB3 Polyester

64/55

60-62

40-45

(a) Nil

61/53

62-66

40-45

(b) 50 GW Partition 11kg

66/58

55-60

40-45

(c) TSB3/ASB3 Polyester

65/57

55-60

40-45

CAViTY inFiLL
(Refer to Section A)

CSR 337
Refer to
AS3600

1 x 10mm GYPROCK
Plasterboard CD.

CSR 959
Refer to
AS3600

1 x 13mm GYPROCK
Plasterboard CD.

CSR 339
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

Refer to
AS3600

CSR 340
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

Refer to
AS3600

CSR 341
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

Refer to
AS3600

CSR 342
Refer to
AS3600

E18

2 x 10mm GYPROCK
SUPERCHEK.

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 346a shown)

PKA056

150mm concrete slab.


Gyprock Resilient Mounts direct fixed to concrete slab
at 600 x 1200mm maximum centres.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CSR 343
30/30/30
EWFA 26162

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

59/50

62-66

40-45

(b) 50 GW Partition 11kg

64/55

58-62

40-45

(c) TSB3/ASB3 Polyester

63/54

58-62

40-45

(a) Nil

60/52

62-66

40-45

(b) 50 GW Partition 11kg

67/59

55-60

40-45

(c) TSB3/ASB3 Polyester

66/58

55-60

40-45

(a) Nil

62/54

60-64

40-45

(b) 50 GW Partition 11kg

67/59

55-60

40-45

(c) TSB3/ASB3 Polyester

66/58

55-60

40-45

(a) Nil

63/55

60-64

40-45

(b) 50 GW Partition 11kg

66/58

55-60

40-45

(c) TSB3/ASB3 Polyester

65/57

55-60

40-45

(a) Nil

64/57

60-62

40-45

(b) 50 GW Partition 11kg

68/61

55-60

40-45

(c) TSB3/ASB3 Polyester

68/61

55-60

40-45

CAViTY inFiLL
(Refer to Section A)

CSR 344
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 345
60/60/60
+RISF 60
minutes
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 346
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 347
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E19

Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 461a shown)

PKA056

125mm concrete slab.


RONDO Suspended Ceiling System.
Minimum 150mm cavity.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CSR 457
Refer to
AS3600

1 x 10mm GYPROCK
Plasterboard CD.

CSR 458
Refer to
AS3600

1 x 13mm GYPROCK
Plasterboard CD.

CSR 459
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

Refer to
AS3600

CSR 460
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

Refer to
AS3600

CSR 461
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

Refer to
AS3600

CSR 462
Refer to
AS3600

E20

2 x 10mm GYPROCK
SUPERCHEK.

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

60/53

65-70

40-45

(b) 50 GW Partition 11kg

65/58

60-65

40-45

(c) 75 GW Partition 11kg

66/59

60-65

40-45

(d) TSB4/ASB4 Polyester

65/58

60-65

40-45

(a) Nil

61/54

65-70

40-45

(b) 50 GW Partition 11kg

66/59

60-65

40-45

(c) 75 GW Partition 11kg

67/60

60-65

40-45

(d) TSB4/ASB4 Polyester

66/59

60-65

40-45

(a) Nil

60/53

65-70

40-45

(b) 50 GW Partition 11kg

65/58

60-65

40-45

(c) 75 GW Partition 11kg

66/59

60-65

40-45

(d) TSB4/ASB4 Polyester

65/58

60-65

40-45

(a) Nil

62/55

65-70

40-45

(b) 50 GW Partition 11kg

67/60

60-65

40-45

(c) 75 GW Partition 11kg

68/61

60-65

40-45

(d) TSB4/ASB4 Polyester

67/60

60-65

40-45

(a) Nil

63/56

60-65

40-45

(b) 50 GW Partition 11kg

68/61

55-60

40-45

(c) 75 GW Partition 11kg

69/62

55-60

40-45

(d) TSB4/ASB4 Polyester

68/61

55-60

40-45

(a) Nil

65/58

60-65

40-45

(b) 50 GW Partition 11kg

70/63

55-60

40-45

(c) 75 GW Partition 11kg

71/64

55-60

40-45

(d) TSB4/ASB4 Polyester

70/63

55-60

40-45

CAViTY inFiLL
(Refer to Section A)

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 463a shown)

PKA056

125mm concrete slab.


RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Minimum 150mm cavity.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CSR 463
30/30/30
EWFA 26162

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channel at
450mm maximum
centres.

CSR 464
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 465
60/60/60
+RISF 60
minutes
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 466
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 467
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

62/55

60-65

40-45

(b) 50 GW Partition 11kg

67/60

55-60

40-45

(c) 75 GW Partition 11kg

68/61

55-60

40-45

(d) TSB4/ASB4 Polyester

67/60

55-60

40-45

(a) Nil

65/58

60-62

40-45

(b) 50 GW Partition 11kg

70/63

55-60

40-45

(c) 75 GW Partition 11kg

71/64

55-60

40-45

(d) TSB4/ASB4 Polyester

70/63

55-60

40-45

(a) Nil

67/61

60-65

40-45

(b) 50 GW Partition 11kg

72/66

55-60

40-45

(c) 75 GW Partition 11kg

73/67

55-60

40-45

(d) TSB4/ASB4 Polyester

72/66

55-60

40-45

(a) Nil

67/61

60-65

40-45

(b) 50 GW Partition 11kg

72/66

55-60

40-45

(c) 75 GW Partition 11kg

73/67

55-60

40-45

(d) TSB4/ASB4 Polyester

72/66

55-60

40-45

(a) Nil

69/63

55-60

40-45

(b) 50 GW Partition 11kg

74/68

50-55

40-45

(c) 75 GW Partition 11kg

75/69

50-55

40-45

(d) TSB4/ASB4 Polyester

74/68

50-55

40-45

CAViTY inFiLL
(Refer to Section A)

E21

Floor/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 557a shown)

PKA056

125mm concrete slab.


RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
Minimum 150mm cavity.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CSR 557
Refer to
AS3600

1 x 10mm GYPROCK
Plasterboard CD.

CSR 958
Refer to
AS3600

1 x 13mm GYPROCK
Plasterboard CD.

CSR 559
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

Refer to
AS3600

CSR 560
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

Refer to
AS3600

CSR 561
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

Refer to
AS3600

CSR 562
Refer to
AS3600

E22

2 x 10mm GYPROCK
SUPERCHEK.

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

61/53

60-65

40-45

(b) 50 GW Partition 11kg

66/58

55-60

40-45

(c) 75 GW Partition 11kg

67/59

55-60

40-45

(d) TSB4/ASB4 Polyester

66/58

55-60

40-45

(a) Nil

62/55

60-65

40-45

(b) 50 GW Partition 11kg

67/60

55-60

40-45

(c) 75 GW Partition 11kg

68/61

55-60

40-45

(d) TSB4/ASB4 Polyester

67/60

55-60

40-45

(a) Nil

61/53

60-65

40-45

(b) 50 GW Partition 11kg

66/58

55-60

40-45

(c) 75 GW Partition 11kg

67/59

55-60

40-45

(d) TSB4/ASB4 Polyester

66/58

55-60

40-45

(a) Nil

63/56

60-62

40-45

(b) 50 GW Partition 11kg

68/61

55-60

40-45

(c) 75 GW Partition 11kg

69/62

55-60

40-45

(d) TSB4/ASB4 Polyester

68/61

55-60

40-45

(a) Nil

64/57

60-62

40-45

(b) 50 GW Partition 11kg

69/62

55-60

40-45

(c) 75 GW Partition 11kg

70/63

55-60

40-45

(d) TSB4/ASB4 Polyester

69/62

55-60

40-45

(a) Nil

66/60

60-62

40-45

(b) 50 GW Partition 11kg

71/65

55-60

40-45

(c) 75 GW Partition 11kg

72/66

55-60

40-45

(d) TSB4/ASB4 Polyester

71/65

55-60

40-45

CAViTY inFiLL
(Refer to Section A)

The Red Book

Floor/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 565a shown)

PKA056

125mm concrete slab.


RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
Minimum 150mm cavity.
Cavity infill as per system table.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CSR 563
30/30/30
EWFA 26162

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.

CSR 564
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 565
60/60/60
+RISF 60
minutes
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 566
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 567
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

Rw / Rw+Ctr

Bare Floor
Ln,w+Ci

Carpet +
underlay
Ln,w+Ci

(a) Nil

63/56

60-62

40-45

(b) 50 GW Partition 11kg

68/61

55-60

40-45

(c) 75 GW Partition 11kg

69/62

55-60

40-45

(d) TSB4/ASB4 Polyester

68/61

55-60

40-45

(a) Nil

66/59

60-62

40-45

(b) 50 GW Partition 11kg

71/64

55-60

40-45

(c) 75 GW Partition 11kg

72/65

55-60

40-45

(d) TSB4/ASB4 Polyester

71/64

55-60

40-45

(a) Nil

68/62

60-62

40-45

(b) 50 GW Partition 11kg

73/67

55-60

40-45

(c) 75 GW Partition 11kg

74/68

55-60

40-45

(d) TSB4/ASB4 Polyester

73/67

55-60

40-45

(a) Nil

68/62

60-62

40-45

(b) 50 GW Partition 11kg

73/67

55-60

40-45

(c) 75 GW Partition 11kg

74/68

55-60

40-45

(d) TSB4/ASB4 Polyester

73/67

55-60

40-45

(a) Nil

70/64

55-60

40-45

(b) 50 GW Partition 11kg

75/69

50-55

40-45

(c) 75 GW Partition 11kg

76/70

50-55

40-45

(d) TSB4/ASB4 Polyester

75/69

50-55

40-45

CAViTY inFiLL
(Refer to Section A)

E23

Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 953 shown)

PKA056

A pitched tiled roof with or without 350g/m2 sarking.


OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses at 600mm maximum centres
(except where noted in system table).
Cavity infill as per system table.
Ceiling lining as per system table, fixed to framing.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CAViTY inFiLL

Steel Roofing
with Anticon

(Refer to Section A)

Tiled Roof
without Sarking

Tiled Roofing
with Sarking

Rw / Rw+Ctr

CSR 948
1 x 10mm GYPROCK
Plasterboard CD.

//

NOTE: Framing at
450mm max. centres.

(a) 165 Gold Batts 3.0

42/32

40/35

42/36

(b) 215 Gold Batts 4.0

43/34

41/36

43/38

(c) 120 Soundscreen 3.0

42/32

40/35

42/36

(a) 165 Gold Batts 3.0

43/33

41/36

43/37

(b) 215 Gold Batts 4.0

44/35

42/37

44/39

(c) 120 Soundscreen 3.0

43/33

41/36

43/37

(a) 165 Gold Batts 3.0

42/32

40/35

42/36

(b) 215 Gold Batts 4.0

43/34

41/36

43/38

(c) 120 Soundscreen 3.0

42/32

40/35

42/36

(a) 165 Gold Batts 3.0

44/35

45/39

46/40

(b) 215 Gold Batts 4.0

46/37

46/40

48/41

(c) 120 Soundscreen 3.0

44/35

45/39

46/40

(a) 165 Gold Batts 3.0

47/38

46/41

48/42

(b) 215 Gold Batts 4.0

49/40

47/43

49/44

(c) 120 Soundscreen 3.0

47/38

46/41

48/42

(a) 165 Gold Batts 3.0

49/40

50/44

51/45

(b) 215 Gold Batts 4.0

51/42

51/45

53/46

(c) 120 Soundscreen 3.0

49/40

50/44

51/45

CSR 952
1 x 13mm GYPROCK
Plasterboard CD.

//

CSR 949
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

//

CSR 950
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 953
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

CSR 951

//

E24

2 x 10mm GYPROCK
SUPERCHEK.

The Red Book

Roof/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 870 shown)

PKA056

A pitched tiled roof with or without 350g/m2 sarking.


OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses at 600mm maximum centres
(except where noted in system table).
Cavity infill as per system table.
Ceiling lining as per system table, fixed to framing.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CAViTY inFiLL

Steel Roofing
with Anticon

(Refer to Section A)

Tiled Roof
without Sarking

Tiled Roofing
with Sarking

Rw / Rw+Ctr

CSR 954
30/30/30
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.

(a) 165 Gold Batts 3.0

44/35

42/38

45/39

(b) 215 Gold Batts 4.0

46/38

43/39

46/40

NOTE: Framing at
450mm max. centres.

(c) 120 Soundscreen 3.0

44/35

42/38

45/39

(a) 165 Gold Batts 3.0

49/40

47/43

50/44

(b) 215 Gold Batts 4.0

51/42

48/44

51/45

(c) 120 Soundscreen 3.0

49/40

47/43

50/44

(a) 165 Gold Batts 3.0

49/40

47/43

50/44

(b) 215 Gold Batts 4.0

51/42

48/44

51/45

(c) 120 Soundscreen 3.0

49/40

47/43

50/44

(a) 165 Gold Batts 3.0

51/42

50/45

52/46

(b) 215 Gold Batts 4.0

52/44

51/45

53/47

(c) 120 Soundscreen 3.0

51/42

50/45

52/46

(a) 165 Gold Batts 3.0

54/45

53/48

55/49

(b) 215 Gold Batts 4.0

55/47

54/49

56/50

(c) 120 Soundscreen 3.0

54/45

53/48

55/49

CSR 956
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 870
60/60/60
+RISF 60
minutes
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 871
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 955
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E25

Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 843 shown)

PKA056

A pitched tiled roof with or without 350g/m2 sarking.


OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses.
RONDO Furring Channel.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CAViTY inFiLL

Steel Roofing
with Anticon

(Refer to Section A)

Tiled Roof
without Sarking

Tiled Roofing
with Sarking

Rw / Rw+Ctr

CSR 862
1 x 10mm GYPROCK
Plasterboard CD.

//

(a) 165 Gold Batts 3.0

44/34

42/37

44/38

(b) 215 Gold Batts 4.0

45/36

43/38

45/40

(c) 120 Soundscreen 3.0

44/34

42/37

44/38

(a) 165 Gold Batts 3.0

45/35

43/38

45/39

(b) 215 Gold Batts 4.0

46/37

44/39

46/41

(c) 120 Soundscreen 3.0

45/35

43/38

45/39

(a) 165 Gold Batts 3.0

45/35

43/38

45/39

(b) 215 Gold Batts 4.0

46/37

44/39

46/41

(c) 120 Soundscreen 3.0

45/35

43/38

45/39

(a) 165 Gold Batts 3.0

46/37

47/41

48/42

(b) 215 Gold Batts 4.0

48/39

48/42

50/43

(c) 120 Soundscreen 3.0

46/37

47/41

48/42

(a) 165 Gold Batts 3.0

49/40

48/43

50/44

(b) 215 Gold Batts 4.0

51/42

49/45

51/46

(c) 120 Soundscreen 3.0

49/40

48/43

50/44

(a) 165 Gold Batts 3.0

47/37

45/40

47/41

(b) 215 Gold Batts 4.0

48/39

46/41

48/43

(c) 120 Soundscreen 3.0

47/37

45/40

47/41

CSR 842
1 x 13mm GYPROCK
Plasterboard CD.

//

CSR 868
1 x 6mm CeminSeal
Wallboard.

//

CSR 863
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 864
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

CSR 843

//

E26

2 x 10mm GYPROCK
Plasterboard CD.

The Red Book

Roof/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 876 shown)

PKA056

A pitched tiled roof with or without 350g/m2 sarking.


OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CSR 844
30/30/30
EWFA 26162

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.

CAViTY inFiLL

Steel Roofing
with Anticon

(Refer to Section A)

Tiled Roof
without Sarking

Tiled Roofing
with Sarking

Rw / Rw+Ctr

(a) 165 Gold Batts 3.0

46/37

44/40

47/41

(b) 215 Gold Batts 4.0

48/40

45/41

48/42

(c) 120 Soundscreen 3.0

46/37

44/40

47/41

(a) 165 Gold Batts 3.0

51/42

49/45

52/46

(b) 215 Gold Batts 4.0

53/44

50/46

53/47

(c) 120 Soundscreen 3.0

51/42

49/45

52/46

(a) 165 Gold Batts 3.0

51/42

49/45

52/46

(b) 215 Gold Batts 4.0

53/44

50/46

53/47

(c) 120 Soundscreen 3.0

51/42

49/45

52/46

(a) 165 Gold Batts 3.0

53/44

52/47

54/48

(b) 215 Gold Batts 4.0

54/46

53/47

55/49

(c) 120 Soundscreen 3.0

53/44

52/47

54/48

(a) 165 Gold Batts 3.0

56/47

55/50

57/51

(b) 215 Gold Batts 4.0

57/49

56/51

58/52

(c) 120 Soundscreen 3.0

56/47

55/50

57/51

CSR 874
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 875
60/60/60
+RISF 60
minutes
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 876
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 867
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E27

Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 850 shown)

PKA056

A pitched tiled roof with or without 350g/m2 sarking.


OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses.
RONDO Furring Channel clipped to Gyprock Resilient
Mounts.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CAViTY inFiLL

Steel Roofing
with Anticon

(Refer to Section A)

Tiled Roof
without Sarking

Tiled Roofing
with Sarking

Rw / Rw+Ctr

CSR 850
1 x 13mm GYPROCK
Plasterboard CD.

//

(a) 165 Gold Batts 3.0

47/37

44/40

47/41

(b) 215 Gold Batts 4.0

48/39

46/41

48/43

(c) 120 Soundscreen 3.0

47/37

44/40

47/41

(a) 165 Gold Batts 3.0

46/36

44/39

46/40

(b) 215 Gold Batts 4.0

47/38

45/40

47/42

(c) 120 Soundscreen 3.0

46/36

44/39

46/40

(a) 165 Gold Batts 3.0

48/39

49/43

50/44

(b) 215 Gold Batts 4.0

50/41

50/44

52/45

(c) 120 Soundscreen 3.0

48/39

49/43

50/44

(a) 165 Gold Batts 3.0

51/42

50/45

52/46

(b) 215 Gold Batts 4.0

53/44

51/47

53/48

(c) 120 Soundscreen 3.0

51/42

50/45

52/46

(a) 165 Gold Batts 3.0

53/44

54/48

55/49

(b) 215 Gold Batts 4.0

55/46

55/49

58/50

(c) 120 Soundscreen 3.0

53/44

54/48

55/49

CSR 854
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

//

CSR 851
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 853
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

CSR 852

//

E28

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

The Red Book

Roof/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 857 shown)

PKA056

A pitched tiled roof with or without 350g/m2 sarking.


OR
A steel sheet roof minimum 0.42mm with minimum
Bradford Anticon 55 insulation over battens.
Ceiling Joists or Trusses.
RONDO Furring Channel clipped to Gyprock Resilient
Mounts. Furring Channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CSR 855
30/30/30
EWFA 26162

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.

CAViTY inFiLL

Steel Roofing
with Anticon

(Refer to Section A)

Tiled Roof
without Sarking

Tiled Roofing
with Sarking

Rw / Rw+Ctr

(a) 165 Gold Batts 3.0

48/39

46/42

49/43

(b) 215 Gold Batts 4.0

50/42

47/43

50/44

(c) 120 Soundscreen 3.0

48/39

46/42

49/43

(a) 165 Gold Batts 3.0

53/44

51/47

54/48

(b) 215 Gold Batts 4.0

55/46

52/48

55/49

(c) 120 Soundscreen 3.0

53/44

51/47

54/48

(a) 165 Gold Batts 3.0

53/44

51/47

54/48

(b) 215 Gold Batts 4.0

55/46

53/48

55/49

(c) 120 Soundscreen 3.0

53/44

51/47

54/48

(a) 165 Gold Batts 3.0

55/46

54/49

56/50

(b) 215 Gold Batts 4.0

56/48

55/49

57/51

(c) 120 Soundscreen 3.0

55/46

54/49

56/50

(a) 165 Gold Batts 3.0

58/49

57/52

59/53

(b) 215 Gold Batts 4.0

59/51

58/53

60/54

(c) 120 Soundscreen 3.0

58/49

57/52

59/53

CSR 856
60/60/60

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

+RISF 30
minutes
EWFA 26162

CSR 857
60/60/60
+RISF 60
minutes
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 858
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 859
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E29

Roof/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 891a shown)

PKA056

Steel sheet roof


Bradford Anticon 55 over timber or steel purlins.
RONDO Suspended Ceiling System.
Cavity infill as per system table.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CAViTY inFiLL
(Refer to Section A)

Rw / Rw+Ctr

CSR 891
1 x 13mm GYPROCK
Plasterboard CD.

//

(a) 140 Gold Batts 2.5

46/37

(b) 120 Soundscreen 3.0

46/37

(a) 140 Gold Batts 2.5

45/36

(b) 120 Soundscreen 3.0

45/36

(a) 140 Gold Batts 2.5

47/38

(b) 120 Soundscreen 3.0

47/38

CSR 896
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

//

CSR 898
30/30/30

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.

EWFA 26162

CSR 892
60/60/60
+RISF 30
minutes
EWFA 26162

CSR 893
60/60/60
+RISF 60
minutes
EWFA 26162

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

(a) 140 Gold Batts 2.5

48/39

(b) 120 Soundscreen 3.0

48/39

1 x 13mm GYPROCK
FYRCHEK
plasterboard.

(a) 140 Gold Batts 2.5

50/42

(b) 120 Soundscreen 3.0

50/42

(a) 140 Gold Batts 2.5

52/44

(b) 120 Soundscreen 3.0

52/44

1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 894
120/120/120
+RISF 60
minutes
EWFA 26162

E30

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

The Red Book

Roof/Ceiling Systems
SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 068a shown)

PKA056

Steel sheet roof


Bradford Anticon 55 over timber or steel purlins.
RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CAViTY inFiLL
(Refer to Section A)

Rw / Rw+Ctr

CSR 065
1 x 10mm GYPROCK
Plasterboard CD.

//

(a) 140 Gold Batts 2.5

45/36

(b) 120 Soundscreen 3.0

45/36

(a) 140 Gold Batts 2.5

46/36

(b) 120 Soundscreen 3.0

46/36

(a) 140 Gold Batts 2.5

45/36

(b) 120 Soundscreen 3.0

45/36

(a) 140 Gold Batts 2.5

47/38

(b) 120 Soundscreen 3.0

47/38

(a) 140 Gold Batts 2.5

48/39

(b) 120 Soundscreen 3.0

48/39

(a) 140 Gold Batts 2.5

49/40

(b) 120 Soundscreen 3.0

49/40

CSR 860
1 x 13mm GYPROCK
Plasterboard CD.

//

CSR 066
1 x 10mm GYPROCK
SUPACEIL
plasterboard.

//

CSR 067
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 068
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

//

CSR 069

//

The Red Book

2 x 10mm GYPROCK
SUPERCHEK
plasterboard.

E31

Roof/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 073a shown)

PKA056

Steel sheet roof


Bradford Anticon 55 over timber or steel purlins.
RONDO Suspended Ceiling System with Gyprock
Resilient Mounts.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CSR 070
30/30/30
EWFA 26162

CeiLinG LininGS

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.

CAViTY inFiLL
(Refer to Section A)

Rw / Rw+Ctr

(a) 140 Gold Batts 2.5

47/38

(b) 120 Soundscreen 3.0

47/38

CSR 071
60/60/60
+RISF 30
minutes
EWFA 26162

CSR 072
60/60/60
+RISF 60
minutes
EWFA 26162

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

(a) 140 Gold Batts 2.5

51/41

(b) 120 Soundscreen 3.0

51/41

1 x 13mm GYPROCK
FYRCHEK
plasterboard.

(a) 140 Gold Batts 2.5

51/43

(b) 120 Soundscreen 3.0

51/43

(a) 140 Gold Batts 2.5

51/43

(b) 120 Soundscreen 3.0

51/43

1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 073
90/90/90
+RISF 60
minutes
EWFA 26162

E32

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

The Red Book

Roof/Ceiling Systems

RISF = Resistance to Incipient Spread of Fire

SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn

TYPiCAL LAYOuT (CSR 865a shown)

PKA056

A low slope metal roof with Bradford Anticon 55.


150mm Timber or Steel Purlins.
RONDO Furring channel at 600mm max. centres except
where noted in system table.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to furring channel.

FRL
Report/Opinion

SYSTeM
n

CeiLinG LininGS

CAViTY inFiLL (Refer to Section A)

Rw / Rw+Ctr

CSR 873
1 x 13mm GYPROCK
Plasterboard CD.

//

(a) 140 Gold Batts 2.5

46/37

(b) 120 Soundscreen 3.0

46/37

(a) 140 Gold Batts 2.5

47/38

(b) 120 Soundscreen 3.0

47/38

(a) 140 Gold Batts 2.5

45/36

(b) 120 Soundscreen 3.0

45/36

CSR 877
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

//

CSR 872
30/30/30
EWFA 26162

1 x 13mm GYPROCK
FYRCHEK
plasterboard.
Furring channels at
450mm maximum
centres.

CSR 878
60/60/60
+RISF 30
minutes
EWFA 26162

CSR 880
60/60/60
+RISF 60
minutes
EWFA 26162

2 x 13mm GYPROCK
FYRCHEK
plasterboard.

(a) 140 Gold Batts 2.5

51/42

(b) 120 Soundscreen 3.0

51/42

1 x 13mm GYPROCK
FYRCHEK
plasterboard.

(a) 140 Gold Batts 2.5

52/43

(b) 120 Soundscreen 3.0

52/43

(a) 140 Gold Batts 2.5

50/42

(b) 120 Soundscreen 3.0

50/42

(a) 140 Gold Batts 2.5

52/44

(b) 120 Soundscreen 3.0

52/44

1 x 16mm GYPROCK
FYRCHEK
plasterboard (any
order).

CSR 865
90/90/90

2 x 16mm GYPROCK
FYRCHEK
plasterboard.

+RISF 60
minutes
EWFA 26162

CSR 866
120/120/120
+RISF 60
minutes
EWFA 26162

The Red Book

3 x 16mm GYPROCK
FYRCHEK
plasterboard.

E33

Ceiling Fire Rated from Above


SYSTeM SPeCiFiCATiOn

TYPiCAL LAYOuT (CSR 983a shown)

ACOuSTiC
OPiniOn
PKA052

Ceiling lining as per system table, fixed to framing.


Steel framing maximum 1.6 BMT at 600mm maximum
centres.
Minimum cavity depth 150mm.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to framing.

FRL
Report/Opinion

60/60/60
from top
only

SYSTeM
n
Above

CSR 981

FAR 2358

60/60/60
from top
only

CeiLinG LininGS

1 x 16mm GYPROCK FYRCHEK.


below
1 x 10mm GYPROCK Plasterboard CD.

CSR 982

2 x 16mm GYPROCK FYRCHEK.


below

FAR 2358

E34

38/31

(b) 50 GW Partition 11kg/m3

42/33

(c) 90 Gold Batts 2.0

45/36

(a) Nil

33/30

(a) Nil

44/37

(b) 75 GW Partition 14kg/m3

50/41

(a) Nil

36/33

(a) Nil

36/33

1 x 10mm GYPROCK Plasterboard CD.


Above

CSR 986

3 x 13mm GYPROCK FYRCHEK.


below
Nil.

Above
120/120/120
3 x 16mm GYPROCK FYRCHEK.
from top
CSR 985
below
only
FAR 2358

(a) Nil

Nil.

Above
120/120/120
2 x 16mm GYPROCK FYRCHEK.
from top
CSR 983
below
only

FAR 2358

Rw / Rw+Ctr

Above

FAR 2358

90/90/90
from top
only

CAViTY inFiLL (Refer to Section A)

Nil.

The Red Book

Ceilings Fire Rated from Above and/or Below


SYSTeM SPeCiFiCATiOn

TYPiCAL LAYOuT (CSR 992a shown)

ACOuSTiC
OPiniOn
PKA052

Ceiling lining as per system table, fixed to framing.


Steel framing maximum 1.6mm BMT at 600mm maximum
centres.
Minimum cavity depth 150mm.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to framing.

FRL
Report/Opinion

60/60/60
FAR 2358

SYSTeM
n

CeiLinG LininGS
Above & below

CSR 994 1 x 16mm GYPROCK FYRCHEK


plasterboard.

90/90/90
Above & below
from below
120/120/120 CSR 992 2 x 16mm GYPROCK FYRCHEK
plasterboard.
from above
FAR 2358

Rw / Rw+Ctr

CAViTY inFiLL (Refer to Section A)


(a) Nil

41/35

(b) 50 GW Partition 11kg/m3

45/37

(a) Nil

47/41

(b) 50 GW Partition 11kg/m3

51/43

(a) Nil

49/43

(b) 50 GW Partition 11kg/m3

53/45

Above

120/120/120 CSR 993


FAR 2358

2 x 16mm GYPROCK FYRCHEK


plasterboard.
below
3 x 16mm GYPROCK FYRCHEK
plasterboard.

SYSTeM SPeCiFiCATiOn

TYPiCAL LAYOuT (CSR 995a shown)

ACOuSTiC
OPiniOn
PKA052

Shaftwall C-H studs at 600mm maximum centres.


Lining to top side as per system table, in framing.
Cavity infill as per system table.
Ceiling lining as per system table, fixed to framing.

FRL
Report/Opinion

60/60/60
from top
only

SYSTeM
n

CeiLinG LininGS
Above

CSR 987

FAR 2358

1 x 25mm GYPROCK SHAFT LINER PANEL.


below
1 x 16mm GYPROCK FYRCHEK plasterboard.
Above

90/90/90
FAR 2358

CSR 995

1 x 25mm GYPROCK SHAFT LINER PANEL.


below
2 x 16mm GYPROCK FYRCHEK plasterboard.
Above

120/120/120 CSR 997 1 x 25mm GYPROCK SHAFT LINER PANEL.


FAR 2358
below

3 x 16mm GYPROCK FYRCHEK plasterboard.

The Red Book

CAViTY inFiLL (Refer to Section A)


STuD DePTH

Rw / Rw+Ctr
64

102

(a) Nil

38/31

42/35

(b) 50 GW Partition 11kg/m3

43/34

47/38

(a) Nil

41/34

46/40

(b) 50 GW Partition 11kg/m3

46/37

51/43

(a) Nil

44/37

48/42

(b) 50 GW Partition 11kg/m3

49/40

53/45

E35

Floor/Ceiling Fire Rated from Above and/or Below


SYSTEM SPECIFICATION Hebel PowerFloor

TYPICAL LAYOUT (Hebel 1635 shown)

Carpet and medium duty underlay.

ACOUSTIC
OPINION
PKA-A071

CSR Hebel PowerFloor.


Timber or steel joists at 600mm maximum centres.

=TL413

RONDO Furring Channel at 600mm maximum centres


fixed to joists with fixing clips (N226).

=TLi413

Cavity infill as per system table.


Ceiling lining as per system table.
Note: Refer to CSR Hebel for design considerations.
FRL
Report/Opinion

SYSTEM
N

CEILING LININGS

CAVITY INFILL

Rw / Rw+Ctr

Ln,w+CI

Hebel 1600
240/240/240
from above
FCO 1303

//
from below

240/240/240
from above
FCO 1303

120/120/120
from below

Nil

(a) Nil

33/30

45

3 x 16mm GYPROCK
FYRCHEK plasterboard

(a) 75 Gold Batts 1.5

58/54

34

Hebel 1635

EWFA 26162

E36

The Red Book

Acoustic Tile Ceiling Systems


SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn
OR
TeST

TYPiCAL LAYOuT

Fricker Suspension Clip


and 5mm hanging rod
staggered at 1200mm
centres

Rondo Duo suspended ceiling system with appropriate


acoustic ceiling tiles.

Refer to
CSR Fricker

Fricker Top Hat Cross


Runner every third tile

OR
Fricker Easy Access System with appropriate acoustic
ceiling tiles
OR
Fricker Ceiling Tile

Plasterboard ceiling or timber battens with


Ecophon Focus F acoustic ceiling tiles.

Fricker Top Hat


Main Runner
Fricker hidden C splines
(back-to-back) not fixed
to system

System CSR 890 with acoustic


ceiling tile options as per below

Material &
Thickness
Mineral Fibre
19mm

USG Mars ClimaPlus


USG Radar ClimaPlus
USG Impressions ClimaPlus
USG Olympia Micro ClimaPlus
USG Millennia ClimaPlus
Daiken Exceltone New NDF

Daiken Exceltone Travertine Delica

Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
19mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
15mm
Mineral Fibre
15mm

Fricker 610-A
Fricker 611-A
Fricker 616-A

Ceiling System

Edge
Details

Colour

NRC

CAC
(db)

LR

SQ
SLT
FLB
SQ
SLT
SQ
SLT
SQ
SLT

White
White
White
White
White
White
White
White
White

.70-.80
.75-.85
.70-.80
.50-.60
.50-.60
.55
.55
.50
.50

35
35
35
33-35
33-35
33-35
33-35
30-35
30-35

89%
89%
89%
84%
84%
84%
84%
87%
87%

SQ

White

.70

35

87%

SQ
TB
AK
SQ
TB
AK
SQ
SBK
SQ
SBK
SQ
SBK

White
White
White
White
White
White
White
White
White
White
White
White

.55-.60
.55-.60
.55-.60
.55-.60
.55-.60
.55-.60
.70
.70
.55
.55
.70
.70

36-40
36-40
36-40
36-40
36-40
36-40
33-39
33-39
33-39
33-39
33-39
33-39

87%
87%
87%
87%
87%
87%
88%
88%
88%
88%
88%
88%

TWE

TWA

OWE

FC

WP

notes:
edge Details

Ceiling System

SQ = Square,
SLT = Shadowline Tapered
FLB = Fineline Bevel
TB = Tegular
SBK = Kerfed, Bevelled and Cut Back
AK = Shiplap
AK (F) = Tongue & Groove direct fix

TWE = Two Way Exposed


TWA = Two Way Access
OWE = One Way Exposed
FC = Fully Concealed
WP = Wall Panel
NRC = Noise Reductionj Coefficient
CAC = Ceiling Attenuation Class
LR = Light Reflectance

Custom tile options, metal pan perforations and module sizes are available. Please contact your local CSR Fricker Comprador sales office on
1300 FRICKER (1300 374 253) for further information or detailed technical data sheets on individual products.

CeiLinG TiLe eDGe DeTAiLS


Square

The Red Book

Shadowline
tapered

Tegular /
Fineline Bevel

Kerfed, Bevelled
and Cut Back

Shiplap

Shiplap (F)

E37

Acoustic Tile Ceiling Systems


SYSTeM SPeCiFiCATiOn

ACOuSTiC
OPiniOn
OR
TeST

TYPiCAL LAYOuT

Fricker Suspension Clip


and 5mm hanging rod
staggered at 1200mm
centres

Rondo Duo suspended ceiling system with appropriate


acoustic ceiling tiles.

Refer to
CSR Fricker

Fricker Top Hat Cross


Runner every third tile

OR
Fricker Easy Access System with appropriate acoustic
ceiling tiles
OR
Fricker Ceiling Tile

Plasterboard ceiling or timber battens with


Ecophon Focus F acoustic ceiling tiles.

Fricker Top Hat


Main Runner
Fricker hidden C splines
(back-to-back) not fixed
to system

System CSR 890 with acoustic


ceiling tile options as per below

Ceiling System

Edge
Details

Colour

NRC

CAC
(db)

LR

SQ
AK
TB
AK (F)
SQ
AK (F)

White Frost
White Frost
White Frost
White Frost
White Frost
White Frost

.85
.80
.80
.75
.95
.95

21
25
23
n/a
30
n/a

85%
85%
85%
85%
85%
85%

Ecophon Solo S

Glasswool
40mm

SQ

White Frost

n/a

n/a

85%

Ecophon Hygiene Meditec

Glasswool
20mm

SQ

White Frost

.80

n/a

84%

SQ

White Frost

.85-.95

n/a

84%

SQ

Turquoise

.95-1.0

n/a

49%

Glasswool
40mm

SQ
SQ
SQ

Brown 610
Cerise 810
Med Grey 920

.95-1.0
.95-1.0
.95-1.0

n/a
n/a
n/a

14%
16%
34%

Plasterboard
13mm

SQ

.49

n/a

n/a

SQ
TB
SQ
TB

.70
.70
.85
.85

13
13
30
30

68%
68%
68%
68%

Ecophon Focus A
Ecophon Focus Ds
Ecophon Focus E
Ecophon Focus F
Ecophon Master A
Ecophon Master F

Material &
Thickness
Glasswool
20mm
Glasswool
40mm

Ecophone Hygiene Performance A


Ecophon Wall Panel A
Ecophon Wall Panel C
Perforated Plasterboard (with
Bradford Anticon 55, foil face up)
Perforated Metal Pan (1820 perf
with black fleece backing)
Perforated Metal Pan (1820 perf
with 18mm x 80kg/m insulation)

Glasswool
20mm
Glasswool
40mm

Steel 0.7mm
Steel 0.7mm

TWE

TWA

OWE

FC

WP

notes:
edge Details

Ceiling System

SQ = Square,
SLT = Shadowline Tapered
FLB = Fineline Bevel
TB = Tegular
SBK = Kerfed, Bevelled and Cut Back
AK = Shiplap
AK (F) = Tongue & Groove direct fix

TWE = Two Way Exposed


TWA = Two Way Access
OWE = One Way Exposed
FC = Fully Concealed
WP = Wall Panel
NRC = Noise Reductionj Coefficient
CAC = Ceiling Attenuation Class
LR = Light Reflectance

Custom tile options, metal pan perforations and module sizes are available. Please contact your local CSR Fricker Comprador sales office on
1300 FRICKER (1300 374 253) for further information or detailed technical data sheets on individual products.

CeiLinG TiLe eDGe DeTAiLS


Square

E38

Shadowline
tapered

Tegular /
Fineline Bevel

Kerfed, Bevelled
and Cut Back

Shiplap

Shiplap (F)

The Red Book

FiG e3: inSTALLATiOn DeTAiL SinGLe LAYeR ADHeSiVe & nAiL/SCReW FiXinG

For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
For 1350mm width sheets, hold
sheet with temporary fastener
through block at every second joist
until adhesive sets

Timber or steel
framing

Adhesive Daubs

nOn-FiRe RATeD
Fixing Specifications

230mm
max.
centres
2 Nails 50 to
75mm apart
or 1 screw

200mm
min. cts
200mm
min. cts

300mm max.
for cornice finish
150mm max.
for set finish

Fasteners
Adhesive

Refer to Section A
Gyprock Stud Adhesive

Location

Fixing & Spacing

Field
Sheet
Width
900mm
1200mm
1350mm

Adhesive Daubs at
230mm max. centres
and 200mm min. from
fastener points
2 daubs
4 daubs
4 daubs

Recessed
Joints

Nail/screw fix at each


frame member

Centreline
of
Sheet

2 nails at 50 to 75mm
apart or 1 screw at each
frame member

Butt
Joints
between
framing

Joint within 50mm of


centre line between
framing and adhesive fix
back-block
Nail fix at 150mm or
screw fix at 200mm
max. centres

Butt
Joints on
framing

For Level of Finish 4 and


5, where Butt Jointing is
unavoidable, joint centrally
between members and
back-block.
Nail at 150mm
or screw at 200mm max.

Openings

Nail fix at 150mm or


screw fix at 200mm
max. centres.

Sheet
Ends

For cornice finish, fasten


at 300mm max. cts.
For set finish, fasten at
150mm max. centres

Where permitted, Butt Joint on


member (Levels of Finish 0 to 3)

Offset butt joints in


adjoining sheets by
600mm minimum

FiG e4: inSTALLATiOn DeTAiL TWO LAYeR ADHeSiVe & SCReW FiXinG

For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.

2nd Layer
Fasteners
Adhesive
1st Layer
Body
Sheet
Width
900mm
1200mm
1350mm
Butt Joints
on framing
Sheet
Ends &
Openings
2nd Layer
Body

200mm max.
230mm
max.

300mm
max.

300mm max.
for cornice finish
150mm max.
for set finish

200mm min.

Adhesive
Daubs

For Levels of Finish 0 to


3, Butt Joint on member
and screw fix at 200mm
max. centres
For Level of Finish 4 and 5,
where Butt Jointing is
unavoidable, joint centrally
between members, fix with
laminating screws at 200mm
Offset Butt Joints in 2nd
layer 600mm min. in
adjoining sheets and
between layers

The Red Book

nOn-FiRe RATeD
Fixing Specifications
1st Layer Refer to Section A
Gyprock Stud Adhesive
Screws

Timber or Steel Framing


at 600mm max. centres

230mm max.
200mm min.

Temporary block

Butt Joints in 1st


layer may be on
same member

Begin 1st layer


with a half
width sheet

Begin 2nd layer with a full width sheet


and offset recessed joint 300mm
minimum between 1st and 2nd layer

Refer to Section A
Gyprock Stud Adhesive
Fixing & Spacing
Screw fix to each
framing member at
300mm max. centres
4 screws equally spaced
5 screws equally spaced
6 screws equally spaced
Screw fix at 200mm
max. centres
Screw fix at 300mm
max. centres

Fixing & Spacing


Adhesive Daubs at
230mm max. centres
Sheet
and 200mm min. from
Width
fastener points
900mm
2 daubs
1200mm 4 daubs
1350mm 4 daubs
Recessed Screw fix at each
Joints
frame member
Centreline Screw fix at each frame
of Sheet
member
Butt Joints Screw fix at 200mm
on framing max. centres
Butt Joints Laminating screws at
between
200mm max. centres
framing
Openings Screws at 200mm max.
centres
Sheet
For cornice finish, screw
Ends
fix at 300mm max. cts.
For set finish, screw fix
at 150mm max. centres

E39

FiG e5: inSTALLATiOn DeTAiL SinGLe LAYeR SCReW FiXinG

For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.

nOn-FiRe RATeD
Practical
minimum 150mm

Structural support
of timber, steel or
concrete

Fixing Specifications
Screws

Suspended Grid at
600mm maximum
centres

Fixing & Spacing

Recessed
Joints
& Body
Sheet
Width
900mm
1200mm
1350mm

Screw fix to each frame


at 10 to 16mm from
sheet edges and at
300mm max. centres
between.
4 screws equally spaced
5 screws equally spaced
6 screws equally spaced

Butt Joints Joint within 50mm of


between
centre line between
framing
framing. Back-block
and fix with laminating
screws at 200mm max.
centres.

300mm
max.

300mm max. for cornice finish


150mm max. for set finish

Refer to Section A

Location

Butt Joints Screw fix at 200mm


on framing max. centres
200mm max.

Openings

Screw fix at 200mm


max. centres

Sheet
Ends

For cornice finish, screw


fix at 300mm max. cts.
For set finish, screw fix
at 150mm max. centres

For Level of Finish 4 and


5, where Butt Jointing is
unavoidable, support
plasterboard with additional
framing
200mm max.
Where permitted, Butt Joint
on member and screw fix at
200mm max. centres
(Levels of Finish 0 to 3)
Offset butt joints in
adjoining sheets by
600mm minimum

FiG e6: inSTALLATiOn DeTAiL PeRFORATeD PLASTeRBOARD SHeeTS

For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
Framing at 600mm centres

nOn-FiRe RATeD
Fixing Specifications

25mm GYPROCK screws


at 300mm centres

Screws

At butt joints, screw at


200mm centres opposed

Refer to Section A

Location

Fixing & Spacing

Recessed
Joints &
Body

Screw fix to each frame


at 10 to 16mm from
sheet edges and at
300mm max. centres
between

Butt Joints Screw fix at 200mm


on framing max. centres
Sheet
Ends

Screw fix at 200mm


max. centres

Openings

Screw fix at 200mm


max. centres

Staggered butt joints


GYPROCK Perforated Plasterboard
(perforations not shown)
Border of standard GYPROCK plasterboard
or finish with wall angle trim

E40

The Red Book

FiG e7: inSTALLATiOn DeTAiL SinGLe LAYeR nAiL OR SCReW FiXinG


FOR SYSTeMS WiTH LininG ABOVe OR BeLOW FRAMinG

For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
FiRe RATeD

Refer to system
specifications

Fixing Specifications
Fasteners

Fixing & Spacing

Body of
Sheet

Fasten to each framing


member at 25mm
from sheet edges and
at 200mm maximum
centres

Butt
Joints

Butt Joint on framing


and fasten at 40mm
from sheet edges,
15mm from sheet ends
and at 150mm max.
centres (offset fasteners)

Openings

Fasten at
150mm max. centres

Sheet
Ends

Fasten at 15mm min.


from sheet edges and at
150mm max. centres

15mm

40mm
25mm

150mm
max.

40mm
15mm
min.

Refer to Section A

Location

200mm max.
150mm max.

Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Details)

Stagger butt joints


in adjacent sheets
and offset fasteners

FiG e8: inSTALLATiOn DeTAiL One OR TWO LAYeR nAiL OR SCReW FiXinG
FOR SYSTeMS WiTH LininG ABOVe OR BeLOW FRAMinG

For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
FiRe RATeD

Refer to system
specifications

Fixing Specifications
Fasteners

40mm
25mm
40mm

40mm 40mm

200mm
max.

150mm
max.
15mm

15mm
min.

25mm

Butt Joints must be offset


600mm minimum in adjoining
sheets and between layers
Perimeter track/angle
required in fire rated
ceiling systems (refer
to Junction Details)
Begin 2nd layer with full width sheet
and offset recessed joint 300mm
minimum between 1st and 2nd layer

The Red Book

Fixing & Spacing

Body of
Sheet
1st & 2nd
Layer

Fasten to each framing


member at 25mm from
sheet edges and at
200mm max. centres

Butt
Joints
1st Layer

Butt Joint on framing


and fasten at 40mm
from sheet edges,
15mm from sheet ends
and at 150mm max.
centres (offset fasteners)

Butt
Joints
2rd layer

Butt Joint within 50mm


of centre line between
framing and fix to 1st
layer with Laminating
Screws at 25mm from
sheet edges, 40mm
from sheet ends and at
200mm max. centres

Sheet
Ends

Fasten at 40mm from


sheet edges, 15mm min.
from sheet ends and at
150mm max. centres

Openings

Fasten at 15mm min.


from sheet edges and at
150mm max. centres

200mm max.

Butt Joints in 2nd


layer must be centred
between framing members
and fixed with laminating
screws

Stagger butt joints


in adjacent sheets
and offset fasteners

Refer to Section A

Location

Begin 1st
layer with half
width sheet

E41

FiG e9: inSTALLATiOn DeTAiL THRee LAYeR FiXinG TO STeeL OR TiMBeR FRAMinG nAiL OR SCReW FiXinG

For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
FiRe RATeD

Suspended Grid, Steel


Framing or Timber Framing at
600mm maximum centres

Fixing Specifications
Fasteners

25mm

40mm

25mm

40mm

40mm
150mm
max.

150mm
40mm
40mm

15mm

15mm
min.

Fixing & Spacing

Body of
Sheet
1st & 2nd
Layers

Fasten to each framing


member at 25mm from
sheet edges and at
200mm max. centres

Butt
Joints
1st & 2nd
Layers

Butt Joint on framing


and fasten at 40mm
from sheet edges,
15mm from sheet
ends and 150mm max.
centres (offset fasteners)

Butt
Joints
3rd layer

Butt Joint within


50mm of centre line
between framing and
fix to previous layer
with Laminating Screws
at 40mm from sheet
edges, 40mm from
sheet ends and 200mm
max. centres

Sheet
Ends all
Layers

Fasten at 40mm from


sheet edges, 15mm min.
from sheet ends and at
150mm max. centres

Body of
Sheet 3rd
Layer

Laminating screws at
400mm max. in each
direction

Openings

Fasten at 15mm min.


from sheet edges and at
150mm max. centres

200mm max.

150mm
max.

15mm

40mm

1st and 2nd layer


Butt Joints on framing
members, offset 600mm
minimum between layers
25mm

Butt Joints in 3rd layer


must be placed centrally
between framing, offset
600mm minimum in adjoining
sheets and from previous layers

400mm
max.

Perimeter track/angle
required in fire rated
ceiling systems (refer
to Perimeter Framing
& Caulking)

200mm
max.
400mm
max.

Refer to Section A

Location

Begin 1st layer with 400mm width sheet


Begin 2nd layer with 800mm width sheet
Begin 3rd layer with full width sheet

FiG e10: inSTALLATiOn DeTAiL PLASTeRBOARD FiXinG TO STeeL FRAMinG


FiRe RATeD FROM ABOVe AnD/OR BeLOW

For additional information, refer to GYP570, Gyprock Ceiling Systems Installation Guide.
FiRe RATeD
Top Layers Fixing Specifications
Fasteners

300mm
max.
150mm
max.

Refer to Section A

Location

Fixing & Spacing

Body of
Sheet
All Layers

Fix to upper framing at


max. 300 centres.
Fix lower framing
through to upper
framing at 200mm max.
centres

Butt
Joints

Fix to upper framing at


300mm max. centres.
Fix lower framing
through to upper
framing at 150mm max.
centres

Sheet
Ends

Fix at 150mm max.


centres

200mm
max.

150mm
max.

FiRe RATeD
150mm
max.

200mm
max.

150mm
max.

Bottom Layers
Fixing Specifications
Fasteners

Refer to Section A

Sheet
fixing

Refer to 1, 2 and 3 layer


installation details
SUITABLE FOR:

E42

The Red Book

FiG e11: TYPiCAL inSTALLATiOn DeTAiL ROnDO DuO eXPOSeD GRiD SuSPenDeD CeiLinG SYSTeM

Practical minimum
150mm

Wall Angle
Trim

1200mm max.
between suspension
points

Main
Tee

300mm
Tile Hold Down Clip
N703 (optional)

Cross Tee

600mm

300mm
GYPROCK plasterboard
or accoustic tile
1200mm

600mm

Cross Tee
Duo 4

Main Tee
Duo 1/Duo 3

FiG e12: TYPiCAL inSTALLATiOn DeTAiL FRiCKeR eASY ACCeSS SYSTeM WiTH ACOuSTiC CeiLinG TiLeS
Fricker Suspension Clip
and 5mm hanging rod
staggered at 1200mm
centres
Fricker Top Hat Cross
Runner every third tile

Modules of
1000 x 1000mm to
1500 x 1500mm
Tiles can be
rotated 90 in
modules

Fricker Ceiling Tile


Fricker Top Hat
Main Runner
Fricker hidden C splines
(back-to-back) not fixed
to system

The Red Book

E43

notes

E44

The Red Book

Section F
Services Systems

Contents
Introduction

F2

Fire Resistance

F2

Acoustic Performance

F2

Framing & Lining

F3

Components

F3

System Specifications

Services Systems with Timber


Framing Rw + Ctr

F4

Services Systems with Steel


Framing Rw + Ctr

F5

Services Systems with Timber


Framing Rw

F6

Services Systems with Steel


Framing Rw

F7

Services Systems with Cavity

Timber or Steel Framing Rw/Rw + Ctr F8

Acoustic Separation Details

The Red Book

F9

F1

Introduction
Gyprock Services Systems are ducts, risers, bulkheads
and ceilings that provide protection from noise generated by
building services. These services include water supply pipes,
waste and storm water pipes, and air conditioning ducts.
The BCA has deemed to satisfy performance requirements
that vary depending on the room use adjacent to the service,
and there are some State variations. The requirements are
R w + Ctr = 25 to a kitchen or non-habitable room, and
Rw + Ctr = 40 for habitable rooms other than kitchens. The
State variations are for Rw = 30 and Rw = 45 for the same
respective room types.
For services located within separating walls, refer to
Section Z for details and performance information.

Fire Resistance
The services systems in this section have no Fire Resistance
Level. They may be used in conjunction with fire rated
wall and ceiling systems selected from elsewhere in this
manual.

Acoustic
Performance
The acoustic transmission performance of the services
systems is dependent on the type of support framing. In
some systems, higher ratings can be achieved with timber
framing compared to light steel framing. In cavity systems,
this does not apply.
Services systems used as bulkheads or ceilings may
incorporate downlights. The distribution of downlights in
a services system is specified as the maximum number
permitted in a 5m 2 area. The lights shall be evenly
distributed and no closer than 900mm apart. Where higher
concentrations of lights are required, an acoustic engineer
should be consulted.
Penetrations for downlights must be neat and tight to the
fitting. No additional sealing is required. Ensure insulation
material is kept clear of fittings and that transformers are
supported separately from the plasterboard lining.
The installation of exhaust grilles and ducting may reduce the
performance of the systems. The building designer should
contact the exhaust system manufacturer for performance
details.
Similarly, access panels might be required. Contact the panel
manufacturer for suitable products.
Lagging of pipes or ducts is specified in some services
systems. Lagging must provide complete coverage for the
full extent of the pipe or duct.

FIG F1: FlooR/CeIlInG oR RooF/CeIlInG wITh downlIGhTs


Bradford Glasswool
batts

Maximum
number of
downlights as
per system
specification

F2

Locally remove
insulation

The Red Book

Framing &
Lining
Framing shown in the system layout is indicative only. The
designer should ensure that framing elements are suitable for
the application. For systems specified with timber framing,
linings must be fixed directly to solid timber joists or studs of
minimum dimension 70 x 35mm that are spaced at 600mm
maximum centres. For all other framing construction, select
services systems that are specified for steel framing.
Except for fire grade plasterboard, fixing to framing may be
fastener only or combination fastener/adhesive. Refer to the
Gyprock Residential Installation Guide, NGYP547 and
Cemintel Wet Area Lining Systems, NFC101 for detailed
fixing, jointing and finishing information.
It should be noted that for all systems, setting joints is only
required for the outer layer.
For walls and ceilings, insulation must not be compressed
between the lining and any lagging or the service being
protected.
FIG F2: InsulaTIon CompRessIon

Components
Refer to Section A of this manual for detailed information on
CSR Gyprock plasterboard and Cemintel lining products,
jointing compounds, and fastener specifications.
CSR recommends steel components manufactured by
Rondo Building Services Pty Ltd. Additional information
on the steel components can be obtained from the Rondo
Building Services Pty Ltd, telephone 1300 367 663.
Downlights may be of any non-gimbal type with glass cover,
suitable for a circular cut-out of up to 80mm diameter. Lights
weighing more than 250g must be supported separately
from the plasterboard lining.
Acoustilag 45 consists of 25mm Bradford glasswool
bonded to 4.5kg/m2 loaded vinyl. The glasswool side is to
be installed facing the service pipe or duct.
Lagging is to completely cover the service duct or pipe. Remove
a 50mm wide strip of glasswool and overlap at joints. Tape with
a quality aluminium tape.

FIG F3: FIRe RaTed ReGal haloGen downlIGhT

75mm 25mm
Insulation

Service

lagging

The Red Book

F3

services systems with Timber Framing Rw + Ctr


sYsTem speCIFICaTIon

aCousTIC
opInIon

TYpICal laYouT (CsR ss44 shown)

pKa058

Service Shaft or Ceiling


Timber studs or joists (min. 70 x 35mm) with direct fixed lining as
per system table.
Cavity insulation 75mm Bradford Glasswool
Partition batts 11kg/m3.
Pipe with Bradford Acoustilag 45 as per system table.

system n

linings

CsR ss44

Insulation
(Refer to System Specification)

pipe lagging

maximum n
downlights
per 5m2

Rw + Ctr

(a) 75 GW Partition 11kg

Nil

26

(b) 75 GW Partition 11kg

Acoustilag 45

40

(a) 75 GW Partition 11kg

Nil

30

(b) 75 GW Partition 11kg

Acoustilag 45

42

(a) Nil

Nil

25

(b) 75 GW Partition 11kg

Nil

28

(a) 75 GW Partition 11kg

Nil

28

(b) 75 GW Partition 11kg

Acoustilag 45

42

(a) Nil

Nil

26

(b) 75 GW Partition 11kg

Acoustilag 45

43

(a) Nil

Nil

31

(b) Nil

Acoustilag 45

45

1 x 10mm GYPROCK
AQUACHEK plasterboard.

CsR ss45
1 x 6mm CeminSeal
Wallboard.

CsR ss01
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

CsR ss02
1 x 13mm GYPROCK
plasterboard CD.

CsR ss04
2 x 10mm GYPROCK
plasterboard CD.

CsR ss46
2 x 16mm GYPROCK
FYRCHEK plasterboard.

F4

The Red Book

services systems with steel Framing Rw + Ctr


sYsTem speCIFICaTIon

aCousTIC
opInIon

TYpICal laYouT (CsR ss10 shown)

pKa058

Service Shaft or Ceiling


Steel studs, joists or furring channels with direct fixed lining as
per system table.
Cavity insulation 75mm Bradford Glasswool
Partition batts 11kg/m3.
Pipe with Bradford Acoustilag 45 as per system table.

system n

linings

Insulation
(Refer to System Specification)

pipe lagging

maximum n
downlights Rw + Ctr
per 5m2

CsR ss08
(a) 75 GW Partition 11kg

Nil

25

(b) 75 GW Partition 11kg

Acoustilag 45

38

(a) 75 GW Partition 11kg

Nil

27

(b) 75 GW Partition 11kg

Acoustilag 45

41

(a) 75 GW Partition 11kg

Nil

26

(b) Nil

Acoustilag 45

36

(c) 75 GW Partition 11kg

Acoustilag 45

40

(a) Nil

Nil

27

(b) Nil

Acoustilag 45

41

(c) 75 GW Partition 11kg

Acoustilag 45

43

Nil

Nil

25

75 GW Partition 11kg/90 Gold Batts

Acoustilag 45

42

Nil

Nil

31

75 GW Partition 11kg/90 Gold Batts

Acoustilag 45

44

1 x 10mm GYPROCK
AQUACHEK plasterboard.

CsR ss10
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

CsR ss11
1 x 13mm GYPROCK
plasterboard CD.

CsR ss12
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

CsR ss13
2 x 10mm GYPROCK
plasterboard CD.

CsR ss17
2 x 16mm GYPROCK
FYRCHEK plasterboard.

The Red Book

F5

services systems with Timber Framing Rw


sYsTem speCIFICaTIon

aCousTIC
opInIon

TYpICal laYouT (CsR ss23 shown)

pKa058

Service Shaft or Ceiling


Timber studs or joists (min. 70 x 35mm) with direct fixed lining as
per system table.
Cavity insulation 75mm Bradford Glasswool
Partition batts 11kg/m3.
Pipe with Bradford Acoustilag 45 as per system table.

system n

linings

CsR ss20

Insulation
(Refer to System Specification)

pipe lagging

maximum n
downlights
per 5m2

Rw

(a) 75 GW Partition 11kg

Nil

30

(b) 75 GW Partition 11kg

Acoustilag 45

50

(a) 75 GW Partition 11kg

Nil

31

(b) 75 GW Partition 11kg

Acoustilag 45

52

(a) 75 GW Partition 11kg

Nil

31

(b) 75 GW Partition 11kg

Acoustilag 45

52

(a) 75 GW Partition 11kg

Nil

31

(b) 75 GW Partition 11kg

Acoustilag 45

52

(a) Nil

Nil

31

(b) 75 GW Partition 11kg

Acoustilag 45

54

(a) Nil

Nil

34

(b) 75 GW Partition 11kg

Nil

40

1 x 10mm GYPROCK
AQUACHEK plasterboard.

CsR ss18
1 x 6mm CeminSeal
Wallboard.

CsR ss21
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

CsR ss22
1 x 13mm GYPROCK
plasterboard CD.

CsR ss23
1 x 13mm GYPROCK
SOUNDCHEK
plasterboard.

CsR ss19
2 x 16mm GYPROCK
FYRCHEK plasterboard.

F6

The Red Book

services systems with steel Framing Rw


sYsTem speCIFICaTIon

aCousTIC
opInIon

TYpICal laYouT (CsR ss39 shown)

pKa058

Service Shaft or Ceiling


Steel studs, joists or furring channels with direct fixed lining as
per system table.
Cavity insulation 75mm Bradford Glasswool
Partition batts 11kg/m3.
Pipe with Bradford Acoustilag 45 as per system table.

system n

linings

CsR ss30

Insulation
(Refer to System Specification)

pipe lagging

maximum n
downlights
per 5m2

Rw

(a) Nil

Nil

22

(b) 75 GW Partition 11kg

Acoustilag 45

48

(a) 75 GW Partition 11kg

Nil

30

(b) 75 GW Partition 11kg

Acoustilag 45

51

(a) 75 GW Partition 11kg

Nil

30

(b) 75 GW Partition 11kg

Acoustilag 45

51

(a) 75 GW Partition 11kg

Nil

30

(b) 75 GW Partition 11kg

Acoustilag 45

50

(a) 75 GW Partition 11kg

Nil

31

(b) 75 GW Partition 11kg

Acoustilag 45

52

(a) Nil

Nil

34

(b) Nil

Acoustilag 45

55

1 x 10mm GYPROCK
AQUACHEK plasterboard.

CsR ss38
1 x 6mm CeminSeal
Wallboard.

CsR ss31
1 x 10mm GYPROCK
SUPERCHEK
plasterboard.

CsR ss32
1 x 13mm GYPROCK
plasterboard CD.

CsR ss34
2 x 10mm GYPROCK
plasterboard CD.

CsR ss39
2 x 16mm GYPROCK
FYRCHEK plasterboard.

The Red Book

F7

services systems with Cavity Timber or steel Framing Rw/Rw+Ctr


sYsTem speCIFICaTIon

aCousTIC
opInIon

TYpICal laYouT (CsR ss40 shown)

pKa052

Service Shaft or Ceiling


Inner layer lining (as per system table) direct fixed to timber
or steel framing, to encase services.
Cavity of 70mm minimum.
Cavity insulation as per system table. For ceiling, minimum
1200mm each side of pipe or duct.
Outer layer/ceiling lining (as per system table) direct fixed
to timber or steel framing. 12mm minimum gap between
framing and inner linning.

system n

linings

CsR ss40

Insulation
(Refer to System Specification)

maximum n
downlights Rw/Rw+Ctr
per 5m2

(a) 50 GW Partition 11kg

Nil

46/37

1 x 10mm GYPROCK Plasterboard CD.

(b) TSB4 Polyester

Nil

46/39

Inner Layer

(a) 50 GW Partition 11kg

Nil

49/40

1 x 10mm GYPROCK Plasterboard CD.

(b) TSB4 Polyester

Nil

49/42

Inner Layer

(a) 50 GW Partition 11kg

Nil

53/44

(b) TSB4 Polyester

Nil

53/46

Inner Layer
1 x 13mm GYPROCK SOUNDCHEK plasterboard.
Outer Layer/CeILIng

CsR ss41
2 x 13mm GYPROCK FYRCHEK.
Outer Layer/CeILIng

CsR ss42
2 x 13mm GYPROCK FYRCHEK.
Outer Layer/CeILIng
2 x 13mm GYPROCK Plasterboard CD.

F8

The Red Book

FIG F4: aCousTIC sepaRaTIon BeTween Room and wasTe pIpe


Rw 45 through wall. (estimate pKa acoustic Consulting).
Rw 30 through ceiling. (CsR ss32a)
Gyprock Wet Area Acrylic Sealant
for acoustic integrity

1 x 13mm
GYPROCK
Plasterboard CD
Waste Pipe
75mm Bradford
Glasswool
Partition Batts 11kg/m3

75mm min.
clearance
75 Partition Batts - 11kg/m3

1 x 10mm
GYPROCK
Plasterboard CD
each side of steel
studs
Habitable room

1 x 13mm GYPROCK
Plasterboard CD
Non-habitable room

FIG F5: aCousTIC sepaRaTIon BeTween Room and wasTe pIpe


Rw+Ctr 40 through wall. (CsR ss11c).
Rw+Ctr 36 through ceiling. (CsR ss11b).
Gyprock Wet Area Acrylic Sealant
for acoustic integrity

Waste
Pipe
75mm Bradford
Glasswool
Partition Batts 11kg/m3

Acoustilag 45
Timber or
steel framing

1 x 13mm
GYPROCK
Plasterboard CD
each side of steel
studs
Habitable room

The Red Book

1 x 13mm GYPROCK
Plasterboard CD
600mm min.

Non-habitable room

F9

notes

F10

The Red Book

Section G

Flanking Path Systems

Contents

The Red Book

Introduction

G2

Flanking Paths via Ceiling

G3 G12

Flanking Paths via Floor

G13 G15

Flanking Paths via Wall

G16 G18

G1

Introduction
Acoustic Performance
Flanking sounds reach adjoining areas by indirect paths,
rather than through the dividing element. The components
and cavities of the walls, floors and ceilings that surround the
dividing element are the main paths for flanking transmission.
When designing for room-to-room performance, all flanking
paths should be considered, as well as the dividing element
itself.
The flanking path values in this section are a guide to the
maximum sound transmission values that would be achieved
in a laboratory test. The rating assumes that the dividing
wall that is being flanked has an equivalent or higher sound
transmission performance (Rw or Rw + Ctr) than the flanking
value. Where a flanking system has a rating higher than that
of the dividing wall, the room-to-room transmission should
be taken as the wall value.
Each flanking path system is represented by a typical layout,
and is associated with one or more details. The details
show an example of the construction required, but must be
amended to suit the system specification and lining. Dividing
walls shown as single studs may be substituted with other
construction such as staggered studs, double studs and
masonry walls to achieve the same results.
Panel ceiling systems must have no lights or penetrations
within 600mm of dividing wall and plasterboard ceilings
must have no acoustically untreated penetrations in rooms
adjacent to dividing wall.
Building systems and construction methods can vary greatly
from site to site. CSR recommends that where acoustic
performance is important, an acoustic engineer be consulted
to assess the suitability of the flanking system values detailed
in this section.

G2

The Red Book

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031
Steel angle to
support ceiling grid

Floor or roof structure.

100mm
min

System insulation

200mm minimum cavity.

Rondo DUO Two-way


Steel Grid Ceiling
System
System insulation

50mm Bradford Glasswool Partition batts


11kg/m3 to extent specified in table.
Ceiling lining as per system table.
Wall with required sound rating.

GYPROCK
Panel
Ceiling
System

EXTENT OF INSULATION
SYSTEM N

CEILING LININGS

1200mm each side


of the wall

Nil

Entire Ceiling

Rw

CSR FP01

(a) Gyprock plasterboard panel 10mm

38

44

45

(b) Ecophon 20mm Focus A, Ds or E 20mm

21

24

25

(c) Ecophon 20mm Focus Glasswool Panels + plasterboard


panels 10mm

42

48

49

(d) Ecophon Master A 40mm

30

31

31

30-35

30-36

30-36

35

35-36

35-36

(ef) USG Radar, Impressions, Olympia Micro 15mm


(f) USG Mars, Millenia 19mm

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031
System insulation

Floor or roof structure.


200mm minimum cavity.

100mm
min

System insulation

Ceiling Framing

50mm Bradford Glasswool Partition batts


11kg/m3 to extent specified in table.
Ceiling lining as per system table.
Wall with required sound rating.

Tape and set or


cornice finish

GYPROCK
plasterboard
ceiling

EXTENT OF BUILDING BLANKET


SYSTEM N

CEILING LININGS

Nil

1200mm each side


of the wall

Entire Ceiling

Rw / Rw+Ctr

CSR FP02

(a) 1 x 10mm GYPROCK Plasterboard panel.

41/32

47/38

48/39

(b) 1 x 13mm GYPROCK Plasterboard panel.

43/34

49/40

50/41

(c) 1 x 13mm GYPROCK FYRCHECK Plasterboard

46/38

52/44

53/45

(d) 1 x 13mm + 1 x 16mm


GYPROCK FYRCHECK Plasterboard

55/47

59/51

60/52

(e) 2 x 13mm GYPROCK FYRCHECK Plasterboard

54/46

58/50

59/51

(f) 2 x 16mm GYPROCK FYRCHECK Plasterboard

55/47

59/51

60/52

The Red Book

G3

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
Fix wall track to ceiling
frame with Rondo 704
Partition Clip

System
insulation

PKAA031

Floor or roof structure.


200mm minimum cavity.
50mm Bradford Glasswool Partition batts
11kg/m3 to extent specified in table.
Ceiling lining as per system table.
Wall with required sound rating, to underside
of ceiling.

Finish Bead as
required

GYPROCK Panel
Ceiling System
continuous over
wall in Rondo
DUO Two-way
Steel Grid

Continuous bead of
CSR Gyprock
Sealant or a closed
cell foam tape
above wall track

EXTENT OF BUILDING BLANKET


SYSTEM N

CEILING LININGS

Nil

1200mm each side


of the wall

Entire Ceiling

Rw
(a) 1 x 10mm GYPROCK Plasterboard panel.

CSR FP03

35

40

42

(b) Ecophon Focus A, Ds or E 20mm

18-21

18-24

18-25

(c) Ecophon Master A 40mm

25-30

25-31

25-31

(d) USG Radar, Impressions, Olympia Micro 15mm

30-35

30-36

30-36

(e) USG Mars, Millenia 19mm

30-35

30-36

30-36

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
System insulation

Ceiling framing

PKAA031

Floor or roof structure.


200mm minimum cavity.
50mm Bradford Glasswool Partition batts
11kg/m3 to extent specified in table.
Ceiling lining as per system table.
Wall with required sound rating, to underside
of ceiling.

Tape and
set or
cornice
finish

GYPROCK
plasterboard
ceiling system
continuous
over wall

EXTENT OF BUILDING BLANKET


SYSTEM N

CEILING LININGS

Nil

1200mm each side


of the wall

Entire Ceiling

Rw

CSR FP04

G4

(a) 1 x 10mm GYPROCK Plasterboard CD.

37

42

42

(b) 1 x 13mm GYPROCK Plasterboard CD.

39

45

45

(c) 1 x 16mm GYPROCK FYRCHECK Plasterboard.

43

48

50

(d) 1 x 13mm + 1 x 16mm


GYPROCK FYRCHECK Plasterboard.

47

48

50

(e) 2 x 13mm GYPROCK FYRCHECK Plasterboard

47

48

50

(f) 2 x 16mm GYPROCK FYRCHECK Plasterboard

48

48

50

The Red Book

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

600mm

Floor or roof structure.


200mm minimum cavity.
600mm wide barrier of Bradford Glasswool
Partition batts 11kg/m3, compressed 30%.
Ceiling lining as per system table.
Wall with required sound rating, to underside
of ceiling.

Finish Bead as
required

GYPROCK Panel
Ceiling System
continuous over
wall in Rondo
DUO Two-way
Steel Grid

Continuous bead of
CSR Gyprock
Sealant or a closed
cell foam tape
above wall track

Bradford
Glasswood 11kg/m3
compressed 30%

SYSTEM N

CSR FP10

CEILING LININGS

Rw

(a) 1 x 10mm GYPROCK Plasterboard panel.

45

(b) USG Radar, Impressions, Olympia Micro 15mm

42

(a) USG Mars, Millenia 19mm

42

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

Ceiling
framing

600mm

Floor or roof structure.


200mm minimum cavity.
600mm wide barrier of Bradford Glasswool
Partition batts 11kg/m3, compressed 30%.
Ceiling lining as per system table.
Wall with required sound rating, to underside
of ceiling.

GYPROCK
plasterboard
ceiling system
continuous
over wall

Tape and
set or
cornice
finish

Bradford
Glasswood 11kg/m3
compressed 30%

SYSTEM N

CSR FP11

The Red Book

CEILING LININGS

Rw

(a) 1 x 10mm GYPROCK Plasterboard CD.

50

(b) 1 x 13mm GYPROCK Plasterboard CD.

50

(c) 1 x 16mm GYPROCK FYRCHEK plasterboard.

50

(d) 1 x 13mm + 1 x 16mm GYPROCK FYRCHEK plasterboard.

50

(e) 2 x 13mm GYPROCK FYRCHEK plasterboard.

50

(f) 2 x 16mm GYPROCK FYRCHEK plasterboard.

50

G5

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031
50mm Glasswool
seal continuous over
wall, held in place
with track or angle

10mm GYPROCK
plasterboard min.
continuous over wall
and fixed to soffit

Floor or roof structure.


200mm minimum cavity.
10mm GYPROCK Plasterboard CD barrier
with 50mm Glasswool seal.
Ceiling lining as per system table.
Wall with required sound rating, to underside
of ceiling.

GYPROCK Panel
Ceiling System in
Rondo DUO
Two-way Steel Grid

Finish Bead as
required
Fix track to ceiling
frame with Rondo
N704

Screw fix ceiling


tile to wall track
Wall with required
sound rating

SYSTEM N

Continuous bead of
CSR Gyprock
Sealant above wall
track

CEILING LININGS

Rw

(a) 1 x 10mm GYPROCK Plasterboard CD.

48

(b) Ecophon Focus A, Ds or E 20mm

35-40

(c) USG Radar, Impressions, Olympia Micro 15mm

40-45

(d) USG Mars, Millenia 19mm

40-45

CSR FP16

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031
50mm Glasswool
seal continuous over
wall, held in place
with track or angle

Floor or roof structure.

10mm GYPROCK
plasterboard min.
continuous over wall
and fixed to soffit

Ceiling frame

200mm minimum cavity.


10mm GYPROCK Plasterboard CD barrier
with 50mm Glasswool seal.
Ceiling lining as per system table.
Wall with required sound rating, to underside
of ceiling.

GYPROCK
plasterboard
ceiling system
continuous
over wall
Wall with required
sound rating

SYSTEM N

CSR FP17

G6

CEILING LININGS

Tape and set or


cornice finish

Fix wall track to


ceiling framing

Rw

(a) 1 x 10mm GYPROCK Plasterboard CD.

50

(b) 1 x 13mm GYPROCK Plasterboard CD.

50

(c) 1 x 16mm GYPROCK FYRCHEK plasterboard.

50

(d) 1 x 13mm + 1 x 16mm GYPROCK FYRCHEK plasterboard.

50

(e) 2 x 13mm GYPROCK FYRCHEK plasterboard.

50

(f) 2 x 16mm GYPROCK FYRCHEK plasterboard.

50

The Red Book

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031
Bradford Wavebar Quadzero
(4.0kg/m2) continuous over
wall and fixed to soffit

Floor or roof structure.

300mm min.

200mm minimum cavity.

600mm min.

Bradford Wavebar Quadzero (4.0kg/m2)


continuous over wall and fixed to soffit with
50mm Glasswool seal.
Ceiling lining as per system table.
Wall with required sound rating, to underside
of ceiling.

GYPROCK Panel
Ceiling System in
Rondo DUO
Two-way Steel Grid

Finish Bead as
required
Continuous bead of
CSR Gyprock Sealant
or closed cell foam
tape above wall track

Fix track to ceiling


frame with Rondo
part 704

Wall with required


sound rating

Screw fix ceiling


tile to wall track

SYSTEM N

50mm Glasswool
Blanket continuous
over wall

CEILING LININGS

Rw

(a) 1 x 10mm GYPROCK Plasterboard CD.

48

(b) Ecophon Focus A, Ds or E 20mm

35-40

(c) USG Radar, Impressions, Olympia Micro 15mm

40-45

(d) USG Mars, Millenia 19mm

40-45

CSR FP20

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031
Bradford Wavebar Quadzero
(4.0kg/m2) continuous over
wall and fixed to soffit

Floor or roof structure.

300mm min.

200mm minimum cavity.

50mm Glasswool
Blanket continuous
over wall

600mm min.

Bradford Wavebar Quadzero (4.0kg/m2)


continuous over wall and fixed to soffit with
50mm Glasswool seal.
Ceiling lining as per system table.
Wall with required sound rating, to underside
of ceiling.

GYPROCK
plasterboard
ceiling system
continuous
over wall
Wall with required
sound rating

SYSTEM N

CSR FP21

The Red Book

CEILING LININGS

Tape and set or


cornice finish
Fix wall track to
ceiling framing

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

50/40

(b) 1 x 13mm GYPROCK Plasterboard CD.

50/40

(c) 1 x 16mm GYPROCK FYRCHEK plasterboard.

50/41

(d) 1 x 13mm + 1 x 16mm GYPROCK FYRCHEK plasterboard.

50/42

(e) 2 x 13mm GYPROCK FYRCHEK plasterboard.

50/42

(f) 2 x 16mm GYPROCK FYRCHEK plasterboard.

50/42

G7

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
Floor or roof structure

PKAA031

Floor or roof structure.


50mm Bradford Glasswool Partition batts
11kg/m3 to 1200mm min. each side of wall.
Ceiling lining as per system table.

GYPROCK panel
ceiling system

Wall with required sound rating.

50mm Bradford
Partition batts
11kg/m3 1200mm
each side of wall
Wall system with
required rating

SYSTEM N

CEILING LININGS

Rw

(a) 1 x 10mm GYPROCK Plasterboard CD.

48

(b) Ecophon Focus A, Ds or E 20mm

40

(c) USG Radar, Impressions, Olympia Micro 15mm

45

(d) USG Mars, Millenia 19mm

45

CSR FP025

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
Floor or roof structure

PKAA031

50mm Bradford
Partition batts
11kg/m3 1200mm
each side of wall

Floor or roof structure.


50mm Bradford Glasswool Partition batts
11kg/m3 to 1200mm min. each side of wall.
GYPROCK
plasterboard ceiling
system

Ceiling lining as per system table.


Wall with required sound rating.

Tape and set or


cornice finish or
shadowline bead
Wall system with
required rating

SYSTEM N

CEILING LININGS

Rw

(a) 1 x 10mm GYPROCK Plasterboard CD.

50

(b) 1 x 13mm GYPROCK Plasterboard CD.

52

(c) 1 x 10mm GYPROCK SUPERCHEK Plasterboard.

54

(d) 1 x 13mm GYPROCK SOUNDCHEK Plasterboard.

55

CSR FP26

G8

The Red Book

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

Roof structure.
500mm minimum average cavity height.

Roof framing
with 500mm
min. average
cavity

R2.5 Glasswool
Gold Batts

Bradford Gold Batts R2.5.


Upper Ceiling 1 x 13mm + 1 x 16mm
GYPROCK FYRCHEK plasterboard.
Cavity 150mm minimum height with 50mm
Bradford Partition Batts 11kg/m3.
Lower Ceiling Lining as per system table.

13mm + 16mm
GYPROCK FYRCHEK
Plasterboard

150mm min. cavity

Wall with required sound rating, to underside


of upper ceiling.

50mm Bradford
partition batts 11kg/m3

Lower ceiling

Tape and set or


cornice finish

Wall system with


required rating

SYSTEM N

LOWER CEILING LININGS

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

65/53

(b) 1 x 13mm GYPROCK Plasterboard CD.

66/54

(c) 1 x 10mm GYPROCK SUPERCHEK Plasterboard.

66/54

(d) 1 x 13mm GYPROCK SOUNDCHEK Plasterboard.

67/55

CSR FP31

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031
Sheet metal or
tiled roof
Roof framing with 500mm
min. average cavity

Roof structure.

Bradford Gold
batts R2.5

500mm minimum average cavity height.


Bradford Gold Batts R2.5.
Ceiling lining as per system table fixed with
28mm furring channel and clips to framing.
Wall with required sound rating.

GYPROCK
plasterboard ceiling

Wall system with


required rating

SYSTEM N

CSR FP35

The Red Book

CEILING LININGS

Furring channel
and min. 40mm
cavity
Tape and set or
cornice finish

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

47/39

(a) 1 x 13mm GYPROCK Plasterboard CD.

51/43

(a) 1 x 10mm GYPROCK SUPERCHEK Plasterboard.

52/44

(a) 1 x 13mm GYPROCK FYRCHEK Plasterboard.

53/45

(a) 1 x 13mm + 1 x 16mm GYPROCK FYRCHEK Plasterboard.

59/51

G9

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
Sheet metal or tiled roof

PKAA031

Roof structure.
Bradford Rockwool insulation between
battens.

Roof framing with


min. 200mm cavity

Bradford Gold
batts R2.5

200mm minimum average cavity height.


Bradford Gold Batts R2.5.
Ceiling lining as per system table fixed to
framing.
Wall with required sound rating. Masonry
wall 110mm min.. thickness, extending to
underside of roof battens.

GYPROCK
plasterboard ceiling
(no acoustically
untreated lights,vents
or similar penetrations)

Tape and set or


cornice finish
Wall system with
required rating

Masonry wall min.


110mm thick

SYSTEM N
CSR FP40

CEILING LININGS

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

65/55

(b) 1 x 10mm GYPROCK SUPACEIL Plasterboard.

65/55

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

20mm
0mm clearance
to stud and
GYPROCK
plasterboard

100mm max.
to first fastener
(Do not fix through
track)

Concrete soffit with thickness as per system


table.

Fill gap with CSR


Gyprock Sealant for
acoustic integrity

Wall with required sound rating.


Stud

SYSTEM N

CSR FP45

G10

CONCRETE SOFFIT THICKNESS

Deflection Head Track


fastened at 600mm
centres max.

Rw / Rw+Ctr

(a) 100mm

55/50

(b) 125mm

55/52

(c) 150mm

56/53

(d) 175mm

57/54

(e) 200mm

58/55

(f) 225mm.

58/56

(g) 250mm.

58/56

The Red Book

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

TYPICAL LAYOUT (Refer to detail below table)

ACOUSTIC
OPINION
PKAA031

Roof structure.
500mm minimum average cavity height.
Bradford Gold Batts R1.5.
Ceiling lining as per system table fixed to framing.
CSR Party Wall system with required sound rating.
Central barrier extending to underside of roof battens.

SYSTEM N

CEILING LININGS

CSR FP50

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

66/54

(b) 1 x 10mm GYPROCK SUPACEIL Plasterboard.

66/54

Non-combustible roofing

Roof battens
Roof framing

Nominal 10mm gap to top of GYPROCK


SHAFT LINER PANEL (track optional)

Fill void between


battens with Rockwool
cavity seal, 300mm
min. width

Battens may be continuous over party


wall. Refer to BCA requirements

Wall Clips at
each H-Stud
both sides of wall

Roof sarking.
For roofs without sarking,
protect Rockwool with
damp course under tiles

16mm GYPROCK FYRCHECK


laminated to GYPROCK SHAFT
LINER PANEL laminating screws at
400mm x 400mm max. centres

Required acoustic insulation


minimum 75mm Bradford
R1.5 Gold batts

600mm max.

Blocking to support
ceiling lining

No acoustically
untreated lights,
vents or similar
penetrations

Tape and set or


cornice finish

200mm min.

Wall Clips at
each H-Stud
both sides of wall

Required acoustic insulation


minimum 75mm Bradford
R1.5 Gold batts

No acoustically
untreated lights,
vents or similar
penetrations

4mm minimum gap

Refer to Party Wall


System Table for wall
lining and insulation

GYPROCK SHAFT
LINER PANEL

20-40mm gap
each side of wall

The Red Book

G11

Flanking Paths via Ceiling


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
Continuously
fill gap with
Gyprock
sealant

PKAA031

Wall with required


sound rating

System insulation

Timber framed floor/ceiling.


75mm Bradford Gold Batts R1.5 in floor/
ceiling system.
Ceiling lining, material and fixing as per
system table.
Double stud wall with required sound rating,
above and below floor/ceiling.

Continuously
fill gap with
Gyprock
sealant

GYPROCK
plasterboard ceiling
system direct fixed to
joists or to furring/batten

Tape and set or


cornice finish

Wall with required


sound rating

PLASTERBOARD FIXING SYSTEM


SYSTEM N

CEILING LININGS

DIRECT FIXED TO TRUSS


OR JOIST

FIXED TO FURRING OR
BATTEN

Rw / Rw+Ctr

CSR FP55

G12

(a) 1 x 13mm GYPROCK Plasterboard CD.

53/47

53/47

(b) 1 x 16mm GYPROCK FYRCHEK plasterboard.

55/49

55/49

(c) 1 x 13mm + 1 x 16mm GYPROCK FYRCHEK


plasterboard.

58/52

58/52

(d) 2 x 13mm GYPROCK FYRCHEK plasterboard.

57/51

57/51

(e) 2 x 16mm GYPROCK FYRCHEK plasterboard.

58/52

58/52

The Red Book

Flanking Paths via Floor


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
Wall with required
sound rating

Timber frame floor with separate joists and


discontinuous flooring.

Discontinuous
flooring

PKAA031

Continuously
fill gap with
Gyprock
sealant

Double stud wall with required sound rating.

SYSTEM N

Rw / Rw+Ctr

CSR FP60

60/55

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

Wall with required


sound rating

Timber frame floor with separate joists and


discontinuous flooring.

Continuously
fill gap with
Gyprock
sealant

Seal skirting with 3mm


polyethylene tape

Single stud wall with required sound rating.


Discontinuous
flooring

The Red Book

SYSTEM N

Rw / Rw+Ctr

CSR FP61

48/42

G13

Flanking Paths via Floor


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

Wall with required


sound rating

Timber framed floor with common joists and


discontinuous flooring.

PKAA031

Continuously
fill gap with
Gyprock
sealant

Seal skirting with 3mm


polyethylene
tape
y

Single stud wall with required sound rating.


Discontinuous
flooring

SYSTEM N

Rw / Rw+Ctr

CSR FP62

45/39

SYSTEM SPECIFICATION

TYPICAL LAYOUT

Wall with required


sound rating

Timber frame floor with common joists and


continuous flooring.

ACOUSTIC
OPINION
PKAA031

Continuously
fill gap with
Gyprock
sealant

Double stud wall with required sound rating.

G14

SYSTEM N

Rw / Rw+Ctr

CSR FP63

45/39

The Red Book

Flanking Paths via Floor


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

Stud

Concrete slab with thickness as per system


table.
Wall with required sound rating.

GYPROCK
plasterboard
Fill gap with CSR Gyprock
Sealant for acoustic
integrity

Studs bottomed
in track
10mm max. gap
at bottom of sheet

SYSTEM N

CSR FP75

The Red Book

CONCRETE SLAB THICKNESS

Rw / Rw+Ctr

(a) 100mm

55/50

(b) 125mm

55/52

(c) 150mm

56/53

(d) 175mm

57/54

(e) 200mm

58/55

(f) 225mm.

58/56

(g) 250mm.

58/56

G15

Flanking Paths via Wall


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

Stud frame wall system with min.


75mm Bradford Gold batts
Fix end stud at
500mm maximum
vertical centres

GYPROCK
plasterboard as
per system table

Timber or steel stud continuous wall system


with 75mm Bradford Gold Batts R1.5.
Plasterboard lining to flanking path side, as
per system table.
Intersecting stud wall system, with required
sound rating.

Tape and
set corners

Intersecting wall with


required sound rating

SYSTEM N

CSR FP80

WALL LININGS

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

45/40

(b) 1 x 10mm GYPROCK SUPERCHEK plasterboard.

48/43

(c) 1 x 13mm GYPROCK SOUNDCHEK plasterboard.

50/45

(d) 1 x 13mm GYPROCK FYRCHEK plasterboard.

50/45

(e) 1 x 16mm GYPROCK FYRCHEK plasterboard.

50/45

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
Stud frame wall system with min.
75mm Bradford Gold batts

PKAA031

GYPROCK
plasterboard as
Steel Angle (75 x 75 x
per system table
0.7mm BMT) fixed to
stud with panhead screw
at 600mm max. cts

Timber or steel stud continuous wall system


with 75mm Bradford Gold Batts R1.5.
Plasterboard lining to flanking path side, as
per system table.
Intersecting stud wall system, with required
sound rating.

Intersecting wall with


required sound rating

Tape and
set corners
CSR Gyprock
Staggered Studs
and Clips

SYSTEM N

CSR FP82

G16

WALL LININGS

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

51/43

(b) 1 x 10mm GYPROCK SUPERCHEK plasterboard.

53/45

(c) 1 x 13mm GYPROCK SOUNDCHEK plasterboard.

54/46

(d) 1 x 13mm GYPROCK FYRCHEK plasterboard.

53/45

(e) 1 x 16mm GYPROCK FYRCHEK plasterboard.

54/46

The Red Book

Flanking Paths via Wall


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT (Refer to detail Z207)


Stud frame wall system with min.
75mm Bradford Gold batts

PKAA031

Fix end stud at 500mm


maximum vertical
centres
Tape and
set corners
Caulk gaps with
Gyprock sealant

Timber or steel stud wall with 75mm Bradford


Gold Batts R1.5.
Plasterboard lining to flanking path side, as
per system table.

Intersecting wall with


required sound rating
Continuous
bead of
sealant

Intersecting wall system of masonry and


separate stud framing, with required sound
rating.

10mm
nom. gap
from
masonry
to lining

Fix end stud to masonry


at 500mm maximum
vertical centres
GYPROCK
plasterboard as
per system table

SYSTEM N

CSR FP84

WALL LININGS

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

51/43

(b) 1 x 10mm GYPROCK SUPERCHEK plasterboard.

52/44

(c) 1 x 13mm GYPROCK SOUNDCHEK plasterboard.

54/46

(d) 1 x 13mm GYPROCK FYRCHEK plasterboard.

53/45

(e) 1 x 16mm GYPROCK FYRCHEK plasterboard.

54/46

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT
Stud frame wall system with min.
75mm Bradford Gold batts

PKAA031

Sealant
GYPROCK
plasterboard as
per system table

Timber or steel stud wall system with 75mm


Bradford Gold Batts R1.5.

Fix end stud at


500mm maximum
vertical centres

Plasterboard lining to flanking path side, as


per system table.
Intersecting stud wall system, with required
sound rating.

Intersecting wall with


required sound rating

Tape and
set corners
Sealant

SYSTEM N

CSR FP86

The Red Book

WALL LININGS

Rw / Rw+Ctr

(a) 1 x 10mm GYPROCK Plasterboard CD.

58/50

(e) 1 x 16mm GYPROCK FYRCHEK plasterboard.

58/50

G17

Flanking Paths via Wall


SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

Intersecting wall with


required sound rating

Finish corners
as required

Continuous masonry wall, with mass as per


system table.
Intersecting stud wall system, with required
sound rating.
CSR Gyprock Fire Mastic to
depth of first layer minimum
CSR Gyprock
Staggered Studs
and Clips

SYSTEM N

CSR FP88

Wall track fixed to


masonry at 600mm
max. centres

MASONRY WALL MASS

Rw / Rw+Ctr

(a) 90kg/m2

53/48

(b) 150kg/m2

55/50

(c) 200kg/m2

56/51

SYSTEM SPECIFICATION

ACOUSTIC
OPINION

TYPICAL LAYOUT

PKAA031

Wall system insulation


Dampcourse
6mm Cemintel Wallboard barrier
full height of wall and fixed to stud

External masonry veneer and continuous stud


wall system with 75mm Bradford Gold Batts
R1.5.

GYPROCK
plasterboard as
per system table

Cemintel Wallboard barrier (as per table).


Plasterboard lining to flanking path side, as
per table.
Intersecting stud wall system, with required
sound rating.

Intersecting wall with


required sound rating

Tape and
set corners

BARRIER
SYSTEM N

WALL LININGS

Nil

6mm Cemintel Wallboard


Rw / Rw+Ctr

CSR FP90

G18

(a) 1 x 10mm GYPROCK Plasterboard CD.

39/30

59/50

(b) 1 x 10mm GYPROCK SUPERCHEK plasterboard.

41/32

60/51

(c) 1 x 13mm GYPROCK SOUNDCHEK plasterboard.

45/37

60/52

(d) 1 x 13mm GYPROCK FYRCHEK plasterboard.

43/35

60/52

(e) 1 x 16mm GYPROCK FYRCHEK plasterboard.

45/37

60/52

The Red Book

Section Z

Junctions & Penetrations

Contents
Junctions

Head & Base Details

Z2 Z6

Wall Junction Details

Z7 Z8

Wall Control Joints

Z9

Ceiling Control Joints

Z10 Z11

Ceiling Perimeter Details

Z12 Z16

Penetrations

The Red Book

Service Penetrations
Acoustic & Fire Performance

Z17 Z18

Penetration Details

Z19 Z24

Z1

Head & Base Details


Non-Fire Rated Applications
Note: Wall/ceiling intersection details require engineers approval where seismic loads are expected.
FIG Z001: FRICTION FIT HEAD

FIG Z004: HEAD FOR


SUSPENDED TEE-LOCK CEILING
Fix track at each
main runner
Main Runner

6 10mm
clearance to
GYPROCK
plasterboard

100mm max.
to first fastener
(Do not fix
through track)

NOTE: Junction may be


finished square, with
stopping bead or with
cornice. Do not rigidly
fix cornice to walls
where friction joints are
used

Fill gap with CSR


Gyprock Sealant for
acoustic integrity

Stud
6mm
clear
of
soffit

Track section with


32mm flange fastened
to soffit at 600mm
centres max.

RONDO P50 or P60


Shadowline Stopping
Bead (finish as
required)
Fix wall sheets at 10
to15mm below head
track flanges

Stud

NOTE: This method of


construction is not
recommended for studs
adjacent to windows or
doors or studs carrying
loads greater than
0.25kPa.

FIG Z005: HEAD FOR SUSPENDED CEILING

FIG Z002: DEFLECTION HEAD

Additional Furring Channel


where wall runs parallel to
setout

Suspended Ceiling
Top Cross Rail

20mm gap
100mm max.
(do not fix
through track)
NOTE: Stopping bead
or cornice finish as
required. Do not rigidly
fix cornice to walls
where friction joints are
used

Fix cornice to
ceiling only with
Gyprock Cornice
Cement

Stud

Deflection Head Track


fastened at 600mm
centres max.

Fix Head Track to Furring


Channel at 600mm max.
centres

Fix wall sheets at 10


to15mm below head
track flanges
Stud

Where wall runs


perpendicular to furring
channel fix track to furring
at each intersection

FIG Z006: WALL BASE DETAIL


STEEL STUD WALL SYSTEM

Fix extruded track at


each furring channel

GYPROCK plasterboard
ceiling fixed to furring
channel at appropriate
centres

Proprietary extruded
aluminium track

Fix track at 600mm max.


centres. With 150mm width
track, use 2 fixings
approximately 20mm in
from each side of track
Fill gap with CSR Gyprock
Sealant for acoustic
integrity

Stud

Z2

Finish as required

Flexible Mastic

FIG Z003: HEAD USING ALUMINIUM HEAD TRACK


Furring
Channel

Furring Channel in
normal setout position

Stud

GYPROCK
plasterboard
Studs bottomed
in track
10mm max. gap
at bottom of sheet

The Red Book

FIG Z007: WALL/CEILING JUNCTION PLASTERBOARD


LINING
System insulation

System
insulation

Ceiling framing

Tape and
set or
cornice
finish

GYPROCK
plasterboard
ceiling system
continuous
over wall

FIG Z008: WALL/CEILING JUNCTION PLASTERBOARD


LINING

100mm
min

System insulation

FIG Z010: WALL/CEILING JUNCTION PANEL LINING

System insulation

Ceiling Framing

Tape and set or


cornice finish

FIG Z009: WALL/CEILING JUNCTION PLASTERBOARD


LINING

Finish Bead as
required

GYPROCK Panel
Ceiling System
continuous over
wall in Rondo
DUO Two-way
Steel Grid

Continuous bead of
CSR Gyprock
Sealant or a closed
cell foam tape
above wall track

FIG Z011: WALL/CEILING JUNCTION PANEL LINING

Steel angle to
support ceiling grid
System insulation

GYPROCK
plasterboard
ceiling

Fix wall track to ceiling


frame with Rondo 704
Partition Clip

100mm
min

Rondo DUO Two-way


Steel Grid Ceiling
System
System insulation

GYPROCK Panel
Ceiling System

FIG Z012: WALL/CEILING JUNCTION PANEL LINING

Floor or roof structure

Floor or roof structure

50mm Bradford
Partition batts
11kg/m3 1200mm
each side of wall

GYPROCK
plasterboard ceiling
system

Tape and set or


cornice finish or
shadowline bead
Wall system with
required rating

The Red Book

GYPROCK panel
ceiling system

50mm Bradford
Partition batts
1200mm each
side of wall
Wall system with
required rating

Z3

CSR Gyprock
Staggered Stud Clip

FIG Z014: STAGGERED STUD BASE WITH RONDO


P140 SPACER (HEAD SIMILAR)

FIG Z016: PREFORMED SHOWER BASE


(Maintains the FRL of the wall system in which it is installed).In many
applications, FRL /60/60 can be achieved using single layer systems.
However, in order to satisfy acoustic requirements between rooms
and corridors, double layer systems or double stud systems are
commonly used..

Plasterboard lining not shown


(minimum 1 x 13mm
GYPROCK FYRCHEK required)

FIG Z013: STAGGERED STUD BASE WITH CSR


GYPROCK STAGGERED STUD CLIP (HEAD SIMILAR)

10mm GYPROCK
AQUACHEK or
FYRCHEK MR
1 or 2 layers of GYPROCK
FYRCHEK MR

Single
or
double
stud
wall
system

Waterproofing sealer
applied to face of
plasterboard behind
tiled area
Vertical Corner
Angle Flashing
Ceramic Tiles
Nogging for
plasterboard fixing
Flashing Tape
(25mm min.)
Flexible Sealant

Screw fix
J-track to
stud

6mm
Preformed
Shower Base
Mortar Bed

Rondo P140 J-track


(100mm length
nominal)

Wet Area Applications

FIG Z017: BATH INSTALLATION


(Maintains the FRL of the wall system in which it is installed).

FIG Z015 INSITU-FORMED SHOWER RECESS CERAMIC


TILED

Single
or
double
stud
wall
system

(Maintains the FRL of the wall system in which it is installed).


1 or 2 layers of
GYPROCK FYRCHEK
MR each side of wall

10mm GYPROCK
AQUACHEK
1 or 2 layers of
GYPROCK
FYRCHEK MR
Ceramic Tiles
Flashing Tape
(25mm min.)

Vertical Corner
Angle Flashing
Ceramic Tiles
Timber Stud
Insitu Internal Membrane
applied to face of
wall lining and floor
Approved Flashing
when required by
building regulations
Masking Tape
Foam plastic rod
used as essential
bond breaker
Mortar Bed

Flexible Sealant

Plasterboard lining not shown


(minimum 1 x 13mm
GYPROCK FYRCHEK required)

Plasterboard lining not shown


(minimum 1 x 13mm
GYPROCK FYRCHEK required)

Single
or
double
stud
wall
system

Approved Flashing when


required by building
regulations
Structural
Sheet Flooring

Continuously
fill 6mm gap
with CSR
Gyprock Fire
Mastic to
13mm
minimum
depth

6mm

Bath
Support Batten
fixed to framing

Mortar Bed

Continuously fill 6mm gap with


CSR Gyprock Fire Mastic to
13mm minimum depth

Z4

Continuously fill 6mm gap with


CSR Gyprock Fire Mastic to
13mm minimum depth

The Red Book

Fire Rated Applications


NOTE: Wall/ceiling intersection details require engineers approval where seismic loads are expected.
FIG Z021: HEAD/BASE STUDS LINED ONE SIDE ONLY

FIG Z018: FRICTION FIT HEAD


(Maintains the FRL of the wall system in which it is installed).

Track section with


32mm flange fastened
to ceiling at 600mm
maximum centres

Continuously fill gap


with CSR Gyprock
Fire Mastic

6 10mm
clearance to
plasterboard

100mm max. to
first fastener. Do
not fix through
head track

NOTE: Junction may


be finished square,
with stopping bead or
with cornice. Do not
rigidly fix cornice to
walls where friction
joints are used

Stud
15mm
clear
of
soffit

Continuously fill gap


with CSR Gyprock
Fire Mastic to 13mm
minimum depth
Track section with
32mm flange fastened
to ceiling at 600mm
maximum centres
GYPROCK
FYRCHEK
plasterboard
1, 2 or 3 layers

100mm
max. to
Nogging
track

60mm
max.

Stud 15mm
clear of soffit
N8 Tek
screw one
side only

GYPROCK
FYRCHEK
plasterboard
1, 2 or 3 layers

NOTE: Junction may be


finished square, with
stopping bead or with
cornice. Do not rigidly fix
cornice to walls where
friction joints are used

Continuously fill gap


with CSR Gyprock
Fire Mastic

N8 Tek
screw both
sides

FIG Z019: DEFLECTION HEAD


(Maintains the FRL of the wall system in which it is installed).

FIG Z022: CEILING/WALL JUNCTION


Furring Channel
over wall
20mm clearance
to stud and
GYPROCK
plasterboard

100mm max. to
first fastener. Do
not fix through
head track

NOTE: Stopping bead


or cornice finish as
required. Do not rigidly
fix cornice to walls
where friction joints
are used

Suspended Ceiling
Top Cross Rail

Continuously fill gap


with CSR Gyprock
Fire Mastic to 13mm
minimum depth

Stud

Deflection Head Track


fastened to ceiling at
600mm maximum
centres
GYPROCK
FYRCHEK
plasterboard
1, 2 or 3 layers

FIG Z020: WALL BASE

10mm Gap

6mm Gap

Gyprock Fire
Mastic

Tape and set if


required

Rondo P50
2 or 3 layers
GYPROCK
FYRCHEK
plasterboard

Stud

1, 2 or 3 layers
GYPROCK
FYRCHEK
plasterboard

FIG Z023: CEILING/WALL JUNCTION

(Maintains the FRL of the wall system in which it is installed).

Metal track fixings at


600mm max. centres.
With 150mm width track,
use 2 fixings
approximately 20mm in
from each side of track
Continuously fill gap
with CSR Gyprock
Fire Mastic to 13mm
minimum depth

The Red Book

Stud

GYPROCK
FYRCHEK
plasterboard
1, 2 or 3 layers
Studs bottomed
in track

10mm Gap

10mm Gap
Continuously fill gap
with CSR Gyprock
Fire Mastic to 13mm
minimum depth
Backing Rod
2 or 3 layers
GYPROCK
FYRCHEK
plasterboard

Continuously fill gap


with CSR Gyprock
Fire Mastic to 13mm
minimum depth

Stud

1, 2 or 3 layers
GYPROCK
FYRCHEK
plasterboard

Z5

FIG Z024: RECESSED SKIRTING DETAIL

FIG Z026: STAGGERED STUD HEAD AND BASE


DETAILS

FRL 90/90/90

Steel track fixed to soffit


16mm GYPROCK
FYRCHEK plasterboard

16mm GYPROCK
FYRCHEK
plasterboard
13mm GYPROCK
FYRCHEK
plasterboard

13mm GYPROCK
FYRCHEK plasterboard
Stud

GYPROCK
Staggered
Stud Clip

Stopping bead
and set finish
1.0mm steel strip
with 50mm min.
overlap

Neat butt joint


6mm Cemintel
Wallboard

400mm
max.

Continuously fill gap


with CSR Gyprock
Fire Mastic

75mm max.

Rebate 12mm
wide max. x 5mm
deep max.
12mm MDF skirting
with 1.0mm steel strip
behind. Separately fix
skirting and steel with
two screws per stud

Staggered
stud profiles
NOTE: Wall/ceiling
junction may be
finished square, with
stopping bead or with
cornice.

15mm
Continuously fill gap
with CSR Gyprock
Fire Mastic to depth
of first layer

GYPROCK
plasterboard

Staggered
stud profiles
bottomed in
track/angle
GYPROCK
plasterboard
GYPROCK
Staggered
stud clip

FIG Z025: RECESSED SKIRTING DETAIL


FRL 120/120/120

16mm GYPROCK
FYRCHEK
plasterboard

75mm max. to
first fastener.

Stud

16mm GYPROCK
FYRCHEK
plasterboard

Continuously fill gap


with CSR Gyprock
Fire Mastic

FIG Z027: STAGGERED STUD WITH RONDO P140


SPACER

Stopping bead
and set finish
1.0mm steel strip
with 50mm min.
overlap

Neat butt joint


9mm Cemintel
Wallboard
Continuously fill gap
with CSR Gyprock
Fire Mastic

400mm
max.

Rebate 10mm
wide max. x 6mm
deep max.
12mm MDF skirting
with 1.0mm steel strip
behind. Separately fix
skirting and steel with
two screws per stud

75mm max.

15mm
Continuously fill gap
with Gyprock Fire
Mastic/FB1 to depth
of first layer

Staggered
studs
NOTE: Wall/ceiling
junction may be
finished square, with
stopping bead or with
cornice.

GYPROCK
plasterboard

GYPROCK
plasterboard

Rondo P140 track


100mm nominal
length fixed to stud

75mm max. to
first fastener.

Z6

Caulk 10mm max.


gap under outer
plasterboard layer
with Gyprock Fire
Mastic/FB1

The Red Book

Wall Junction Details


Fire Rated Applications
NOTE: Wall intersection details require engineers approval where seismic loads are expected. These details are also suitable
for non fire rated applications. Where acoustic integrity is required, refer to Flanking Details.
FIG Z028: CORNER DETAIL PLASTERBOARD WALL

FIG Z030: WALL END DETAIL PLASTERBOARD WALL

Set corner with external angle


bead and cement

Extent of FRL
600mm max.

Screw fix studs


at 600mm max.
vertical centres

100mm max.

Track

Set corner with


paper tape and
cement

100mm max.
to first track
fixing

Set corners
Bottom track
fastened to floor
with metal fasteners

Stud

GYPROCK
FYRCHEK
plasterboard

FIG Z031: PLASTERBOARD TO MASONRY WALL


INTERSECTION
GYPROCK
FYRCHEK
plasterboard

Fix at 600mm
max. centres
along track

Metal track
fixings
Track

(Maintains the FRL of the wall system in which it is installed).


Caulk gap with CSR
Gyprock Fire Mastic equal
to thickness of 1st layer of
plasterboard minimum
GYPROCK
FYRCHEK
plasterboard

Fix end stud to masonry at 6-20mm


500mm maximum vertical
centres

Track

FIG Z029: INTERSECTION DETAIL PLASTERBOARD


WALL
Stud at wall
intersection

Fix studs at 600mm


max. vertical centres

100mm max.

Metal track
fixings

FIG Z032: ANGLED WALL INTERSECTION DETAIL

ax

Provide full height


sheet support when
wall angle is more
than 25

Track

10

0m

Track

Track fixing 100mm


max. from wall
intersection

Set corners with


paper tape and
cement

100mm max.
to first track
fixing

Metal track
fixings
GYPROCK
FYRCHEK
plasterboard

Fix at 600mm
max. centres
along track
Track

Metal track
fixings

Set corner with


external angle
bead and cement

Set corner with


internal angle
bead and cement
Track

GYPROCK
FYRCHEK
plasterboard

The Red Book

Z7

FIG Z033: WALL/WALL JUNCTION

FIG Z035: TYPICAL LAYOUT FOR STAGGERED STEEL


STUD SYSTEM

Stud frame wall system with min.


75mm Bradford Gold batts

GYPROCK
plasterboard

64 mm x 0.75mm
BMT Steel stud

Steel Angle (75 x 75 x


0.7mm BMT) fixed to
stud with panhead screw
at 600mm max. cts
GYPROCK
Plasterboard
92 mm Stud

Wall with required


sound rating

Attach with
plasterboard
laminating screws at
600 mm centres

Tape and
set corners
CSR Gyprock
Staggered Studs
and Clips

FIG Z034: STAGGERED STUD SYSTEM


JUNCTION DETAILS

Intersecting wall with


required sound rating

Finish corners
as required

CSR Gyprock Fire Mastic to


depth of first layer minimum
CSR Gyprock
Staggered Studs
and Clips

Z8

Wall track fixed to


masonry at 600mm
max. centres

The Red Book

Wall Control Joints


Non-Fire Rated Applications

Fire Rated Applications

FIG Z036: CONTROL JOINT STEEL OR TIMBER STUD


WALLS WITH GYPROCK PLASTERBOARD LININGS

FIG Z039: CONTROL JOINT FOR SINGLE LAYER WALL


SYSTEMS, STEEL OR TIMBER STUD FRAME

For Rw up to 40, use backing rod only detail.


For Rw greater than 40, use backing rod and sealant detail.

(Maintains the FRL of the wall system in which it is installed).

15-20mm
gap

Finish surface
as per external angles

CSR Gyprock Flexible


Sealant (depth equal to
wall lining thickness) for
acoustic integrity

Additional stud to
form control joint

Stud in
normal
position

RONDO P35
Control Joint

16mm GYPROCK FYRCHEK


plasterboard

RONDO P35
Control Joint
or alternative

Backing Rod
non fire rated 22mm dia.

Tracks discontinuous
at control joint

Additional stud to
form control joint
15mm min.

Finish surface
as per external angles
Finish surface
as per external angles

Backing Rod
non fire rated
22mm dia. for
acoustic integrity

15-20mm
gap

FIG Z037: CONTROL JOINT STEEL OR TIMBER STUD


WALLS WITH CSR FIBRE CEMENT WALLBOARD
LINING
For Rw up to 40, use backing rod only detail.
For Rw greater than 40, use backing rod and sealant detail.

Finish surface
as per external angles

RONDO P35
Control Joint

15mm min.

Stud in
normal
position

GYPROCK
Plasterboard

RONDO P35
Control Joint

15-20mm
gap

CSR Gyprock Flexible


Sealant (depth equal to
wall lining thickness) for
acoustic integrity

Additional stud to
form control joint
Stud in
normal
position

15-20mm

(Maintains the FRL of the wall system in which it is installed).

CSR Gyprock Fire Mastic


(depth 20mm min.)

2 x 16mm GYPROCK
FYRCHEK plasterboard

20mm min.
RONDO P35
Control Joint
or alternative

Backing Rod
non fire rated
22mm dia.

Stud in
normal
position

Tracks discontinuous
at control joint

Additional stud to
form control joint

Cemintel
Wallboard

Backing Rod
non fire rated
22mm dia. for
acoustic integrity

15-20mm
gap

13mm GYPROCK
FYRCHEK plasterboard

FIG Z040: CONTROL JOINT FOR DOUBLE LAYER WALL


SYSTEMS STEEL OR TIMBER STUD FRAME

20mm min.
Finish surface
as per external angles

Finish surface
as per external angles

CSR Gyprock Fire Mastic


(depth 15mm min.)

15-20mm

2 x 13mm GYPROCK
FYRCHEK plasterboard

FIG Z041: CONTROL JOINT FOR COMPOSITE WALL


SYSTEMS STEEL OR TIMBER STUD FRAME
(Maintains FRL of the wall system in which it is installed).

FIG Z038: CONTROL JOINT AT INTERSECTION OF


MASONRY AND STEEL STUD WALL
Fill gap with CSR
Gyprock Flexible
sealant for acoustic
integrity

CSR Gyprock Sealant


(full depth of wall lining
materials)

Stud in normal
position

RONDO Stopping
Bead and set over

Additional stud to
form control joint

IBS Rod 22mm dia.

Track

Backing Rod 22mm dia.


non fire rated

Do not fix
plasterboard
to end stud

10mm

100 to 150mm

The Red Book

13 or 16mm GYPROCK
FYRCHEK plasterboard

Tracks discontinuous
at control joint

10mm

Cemintel
Wallboard

CSR Gyprock Fire


Mastic (full depth of wall
lining materials)

Z9

Ceiling Control Joints


FIG Z042: CONTROL JOINT PARALLEL TO STEEL
FRAMING 1 LAYER

FIG Z045: CONTROL JOINT PERPENDICULAR TO


STEEL FRAMING 1 LAYER

(Maintains FRL of the ceiling system in which it is installed).

(Maintains FRL of the ceiling system in which it is installed).

Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet

Fix one side of back-block


with laminating screws at
600mm max. centres or
plaster based adhesive

60 to 70mm

Furring
Channel

Fix one side of back-block


with laminating screws at
600mm max. centres or
plaster based adhesive

Back-block between furring


channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet
Rondo N140 Track
200mm min.

Furring Channel

RONDO P35
Control Joint
with set finish

15 to 20mm gap

1 layer GYPROCK
FYRCHEK
plasterboard screw
fixed to furring
channel each side of
joint at 200mm max.
centres

RONDO P35
Control Joint
with set finish

15 to 20mm gap

GYPROCK FYRCHEK
plasterboard fixed to
N140 Track at 200mm
max. centres

FIG Z043: CONTROL JOINT PARALLEL TO STEEL


FRAMING 2 LAYERS

FIG Z046: CONTROL JOINT PERPENDICULAR TO


STEEL FRAMING 2 LAYERS

(Maintains FRL of the ceiling system in which it is installed).

(Maintains FRL of the ceiling system in which it is installed).

Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
Furring
Channel

Continuously fill gap


with CSR Gyprock
Fire Mastic to depth
of first layer minimum

60 to 70mm

Back-block between furring


channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive

Continuously fill gap


with CSR Gyprock
Fire Mastic to depth
of first layer minimum
Furring Channel
Joiner N138
200mm min.

Furring Channel

RONDO P35
Control Joint
with set finish

15 to 20mm gap

2 layers GYPROCK
FYRCHEK
plasterboard screw
fixed to furring each
side of joint at 200mm
max. centres

RONDO P35
Control Joint
with set finish

15 to 20mm gap

GYPROCK FYRCHEK
plasterboard fixed with
laminating screws to
layer above at 200mm
max. centres

FIG Z044: CONTROL JOINT PARALLEL TO STEEL


FRAMING 3 LAYERS

FIG Z047: CONTROL JOINT PERPENDICULAR TO


STEEL FRAMING 3 LAYERS

(Maintains FRL of the ceiling system in which it is installed).

(Maintains FRL of the ceiling system in which it is installed).

Continuous back-block of
GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix one side of back-block
with laminating screws at
600mm max. centres or
plaster based adhesive
Furring
Channel
each side
of joint

RONDO P35
Control Joint
with set finish

Continuously fill gap


with CSR Gyprock
Fire Mastic to depth
of first layer minimum
60 to 70mm

Fix one side of back-block


with laminating screws at
600mm max. centres or
plaster based adhesive

Continuously fill gap


with CSR Gyprock
Fire Mastic to depth
of first layer minimum
200mm min.

Furring Channel

15 to 20mm gap
3rd layer of GYPROCK
FYRCHEK plasterboard
fixed with laminating screws
at 200mm max. centres

Z10

Back-block between furring


channel with GYPROCK
FYRCHEK same thickness
as ceiling sheet

1st and 2nd layers of


GYPROCK FYRCHEK
plasterboard fixed to
furring at 200mm max.
centres

RONDO P35
Control Joint
with set finish

15 to 20mm gap

2nd and 3rd layers of


GYPROCK FYRCHEK
plasterboard fixed with
laminating screws to
layer above at 200mm
max. centres

The Red Book

FIG Z048: CONTROL JOINT PARALLEL OR


PERPENDICULAR TO TIMBER OR STEEL FRAMING
2 LAYERS

FIG Z051: CONTROL JOINT PARALLEL OR


PERPENDICULAR TO TIMBER OR STEEL FRAMING
3 LAYERS

(Maintains FRL of the ceiling system in which it is installed).

(Maintains FRL of the ceiling system in which it is installed).

Continuously and
completely fill gap
with CSR Gyprock
Fire Mastic

NOTE: Control Joint must be


placed centrally between joists
when installed parallel to framing

1 layer GYPROCK
FYRCHEK plasterboard
continuous across joint

Laminating screws at
200mm max. centres

RONDO
Stopping Bead
with set finish

NOTE: Control Joint must be


placed centrally between joists
when installed parallel to framing

10 to 12mm gap

NOTE: Aluminium Foil


must be placed under
joist where control joint is
perpendicular to framing.
Refer to FIG Z041.

Continuously and
completely fill gap
with CSR Gyprock
Fire Mastic
2 layers GYPROCK
FYRCHEK plasterboard
continuous across joint

Laminating screws at
200mm max. centres

NOTE: Aluminium Foil must


be placed under joist where
control joint is perpendicular
10 to 12mm gap to framing. Refer to FIG Z044.

RONDO
Stopping Bead
with set finish

FIG Z049: CONTROL JOINT PARALLEL TO TIMBER


FRAMING 2 LAYERS

FIG Z052: CONTROL JOINT PERPENDICULAR TO


TIMBER FRAMING 2 LAYERS

(Maintains FRL of the ceiling system in which it is installed).

(Maintains FRL of the ceiling system in which it is installed).

Back-block between trimmers


with GYPROCK FYRCHEK same
thickness as ceiling sheet
Laminating screws at
200mm max. centres

Back-block between trimmers


with GYPROCK FYRCHEK same
thickness as ceiling sheet

Continuously fill gap


with CSR Gyprock
Fire Mastic to depth
of first layer minimum

Laminating screws at
200mm max. centres

Trimmers at 450mm
max. centres

Joist
Joist

RONDO P35
Control Joint
with set finish

200mm min.

GYPROCK
FYRCHEK
plasterboard

15 to 20mm gap

300mm min.

Joist

200mm min.

Continuously fill gap


with CSR Gyprock
Fire Mastic to depth
of first layer minimum

GYPROCK
FYRCHEK
plasterboard

15 to 20mm gap
RONDO P35
Control Joint
with set finish

Laminating screws at
200mm max. centres

Laminating screws at
200mm max. centres

Aluminium Foil under joist,


300 x 150 x 0.15mm

FIG Z050 CONTROL JOINT PARALLEL TO TIMBER


FRAMING 3 LAYERS

FIG Z053: CONTROL JOINT PERPENDICULAR TO


TIMBER FRAMING 3 LAYERS

(Maintains FRL of the ceiling system in which it is installed).

(Maintains FRL of the ceiling system in which it is installed).

Back-block between trimmers


with GYPROCK FYRCHEK same
thickness as ceiling sheet
Fix back-block to ceiling sheet
with plaster based adhesive
or laminating screws

Back-block between trimmers


with GYPROCK FYRCHEK same
thickness as ceiling sheet

Continuously fill gap


with CSR Gyprock
Fire Mastic to depth
of first layer minimum

Continuously fill gap with CSR


Gyprock Fire Mastic to depth
of one layer minimum

Fix back-block to ceiling sheet


with plaster based adhesive
or laminating screws

Trimmers at 450mm
max. centres

300mm min.
Joist

RONDO P35
Control Joint
with set finish

200mm min.

15 to 20mm gap

Joist

GYPROCK
FYRCHEK
plasterboard

Fix 2nd and 3rd layers to


preceeding layer with
laminating screws at 200mm
max. centres

The Red Book

Joist

200mm min.

15 to 20mm gap
RONDO P35
Control Joint
with set finish
Aluminium Foil under joist,
300 x 150 x 0.15mm

GYPROCK
FYRCHEK
plasterboard

Fix 2nd and 3rd layers to


preceeding layer with
laminating screws at
200mm max. centres

Z11

Ceiling Perimeter Details


Fire Rated Details
At fire rated ceiling/wall junctions, ceiling framing is required to support the plasterboard as detailed in FIG Z101 to FIG Z130.
To seal the junction between the ceiling and wall, one of the caulking details FIG Z140 to FIG Z147 must be used. The junction
detail should be selected with regard to appearance and acoustic integrity.
FIG Z100: CEILING PERIMETER FRAMING AND CAULKING SELECTION

Step 1:

Step 2:

Choose a suitable
ceiling perimeter
framing detail.
Refer to
FIG Z101
to
FIG Z130

Choose a suitable
perimeter caulking
detail.
Refer to
FIG Z140
to
FIG Z147

CEILING PERIMETER FRAMING AT JUNCTION WITH TIMBER FRAMED WALL


FIG: Z101

FIG: Z102
600mm max.

Ceiling Joist

Angle may be
required as backing
for caulking

1 or 2 layers of
GYPROCK FYRCHEK

Refer to FIG Z100


NOTE: Caulking of the
ceiling perimeter may
be necessary before
fixing wall linings

GYPROCK
Plasterboard

1 or 2 layers of
GYPROCK FYRCHEK

Packer to suit
Non fire
rated or
lower
rated
timber
wall
system

Rondo Wall Track fixed at


600mm max. centres
Blocking to suit FRL. Refer to 'National
Association of Forest Industries Ltd'
publication 'MRTFC'
GYPROCK
Plasterboard

FIG: Z103

FIG: Z104

600mm max.

200mm max.

Ceiling Joist

1, 2 or 3 layers of
GYPROCK FYRCHEK

50x50mm Plasterers Steel


Angle or Wall Track fixed at
600mm max. centres

Refer to FIG Z100


NOTE: Caulking of the
ceiling perimeter may
be necessary before
fixing wall linings

Z12

GYPROCK
Plasterboard

1, 2 or 3 layers of
GYPROCK FYRCHEK

Non fire
rated or
lower
rated
timber
wall
system

Rondo Wall Track fixed at


600mm max. centres
Blocking to suit FRL up to 90/90/90
Refer to 'National Association of Forest
Industries Ltd' publication 'MRTFC'
GYPROCK
Plasterboard

The Red Book

CEILING PERIMETER FRAMING AT JUNCTION WITH FIRE RATED STEEL FRAMED WALL
FIG: Z111

FIG: Z112

600mm max.

200mm max.

1, 2 or 3 layers of
GYPROCK FYRCHEK
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners

Rondo Wall Track fixed at


600mm max. centres with
metal fasteners

1, 2 or 3 layers of
GYPROCK FYRCHEK

Fire rated
wall system
Refer to FIG Z100

FIG: Z113

FIG: Z114

600mm max.

1, 2 or 3 layers of
GYPROCK FYRCHEK

Steel Track fixed at


600mm max. centres
with metal fasteners

Refer to FIG Z100

Steel Angle or Track fixed


at 600mm max. centres
with metal fasteners
Fire rated
wall system

FIG: Z115

FIG: Z116

200mm max.

600mm max.

1, 2 or 3 layers of
GYPROCK FYRCHEK
Steel Angle fixed at
600mm max. centres with
metal fasteners
Refer to FIG Z100

The Red Book

1, 2 or 3 layers of
GYPROCK FYRCHEK

Steel Angle fixed at


600mm max. centres with
metal fasteners

1, 2 or 3 layers of
GYPROCK FYRCHEK

Fire rated
wall system

Z13

CEILING PERIMETER FRAMING AT JUNCTION WITH MASONRY WALL


FIG: Z121

FIG: Z122

Wall track or angle fixed at


600mm max. centres with
metal fasteners

1, 2 or 3 layers of
GYPROCK FYRCHEK

Masonry
wall system

600mm max.

1, 2 or 3 layers of
GYPROCK FYRCHEK

Refer to FIG Z100

FIG: Z123

FIG: Z124
600mm max.
Refer to FIG Z100

Ceiling Joist

Angle may be required


as backing for caulking

1, 2 or 3 layers of
GYPROCK FYRCHEK

Packer to suit
Continuous strip of 16mm
GYPROCK FYRCHEK

1, 2 or 3 layers of
GYPROCK FYRCHEK

Rondo Wall Track


Masonry
wall system

FIG: Z125

FIG: Z126
600mm max.
Refer to FIG Z100

Ceiling Joist

1, 2 or 3 layers of
GYPROCK FYRCHEK

Angle may be
required as backing
for caulking
Wire Mesh (galvanised)
nailed to wall plate
Render

Z14

Packer to suit
Masonry
wall system

1, 2 or 3 layers of
GYPROCK FYRCHEK

Rondo Wall Track


Render

The Red Book

CEILING PERIMETER FRAMING AT JUNCTION WITH MASONRY WALL

FIG: Z127

FIG: Z128
600mm max.

Refer to FIG Z100

Ceiling Joist

1, 2 or 3 layers of
GYPROCK FYRCHEK

Angle may be
required as backing
for caulking
Gyprock Masonry Adhesive
(large daubs to bridge cavity)

Packer to suit
Masonry
wall system

GYPROCK
Plasterboard CD

1, 2 or 3 layers of
GYPROCK FYRCHEK

Rondo Wall Track


GYPROCK
Plasterboard CD

FIG: Z129

FIG: Z130

600mm max.

200mm max.
Masonry
wall system

1, 2 or 3 layers of
GYPROCK FYRCHEK

1, 2 or 3 layers of
GYPROCK FYRCHEK
Rondo Wall Track fixed at
600mm max. centres with
metal fasteners
Refer to FIG Z100

The Red Book

Rondo Wall Track fixed at


600mm max. centres with
metal fasteners

Z15

Caulking Details for Fire Rated Ceilings


P e r i m e t e r c a u l k i n g d e t a i l s Z 1 4 0 t o Z 1 4 7 w i l l m a i n t a i n t h e F R L o f t h e C S R G y p ro c k c e i l i n g s y s t e m s
in which they are installed. Assessment FCO 0609
FIG: Z143

Suitable for 2 and 3 layer plasterboard ceiling systems.

Suitable for 2 and 3 layer plasterboard ceiling systems.


6mm gap min.

Framing to appropriate detail

10mm
min.

Wall System

Wall System

FIG: Z140

Backing rod
(non fire rated)
Continuously fill gap at
edge of sheet with
CSR Gyprock Fire Mastic
min. 16mm depth

Framing to appropriate detail

Continuously fill gap at


edge of all sheets with
CSR Gyprock Fire Mastic

FIG: Z141

FIG: Z144

Suitable for 2 and 3 layer plasterboard ceiling systems.

Suitable for 1, 2 and 3 layer plasterboard ceiling systems.

Wall System

Wall System

6mm gap min.


Framing to appropriate detail

Shadowline stopping bead


Rondo P50

Framing to appropriate detail

Continuously fill gap at


edge of all sheets with
vermiculite plaster

Continuously fill gap at


edge of sheet with
CSR Gyprock Fire Mastic
min. 16mm depth

Tape and set joint

FIG: Z145

Suitable for 1, 2 and 3 layer plasterboard ceiling systems.

Suitable for 1, 2 and 3 layer plasterboard ceiling systems.


6mm gap min.

Framing to appropriate detail


Wall System

Wall System

FIG: Z142

6mm max. gap


Trowel on a continuous
25 x 25mm fillet
of Vermiculite plaster

Framing to appropriate detail

Timber moulding
Continuously fill gap at
edge of all sheets with
Vermiculite plaster

FIG: Z146

FIG: Z147

Suitable for 1, 2 and 3 layer plasterboard ceiling systems.


NOTE: This detail is not suitable were acoustic integrity is required.

Suitable for 2 and 3 layer plasterboard ceiling systems.


NOTE: This detail is not suitable were acoustic integrity is required.

70mm max.

Masonry
wall system

Z16

Wall Angle Trim


Rondo DUO 5 fixed to
wall with metal
fasteners at 600mm
max. centres

Wall System

6mm gap
max.

Framing to appropriate detail

Shadowline stopping bead


Rondo P50
22mm IBS rod

NOTE: Wall surface


behind angle must be
flush. Fill any raked
joints behind angle.

The Red Book

Service Penetrations
Acoustic Performance
The acoustic performance of walls and ceilings can be
reduced by penetrations for plumbing, electrical switches,
light fittings, etc. For construction that is acoustically
sensitive, it is recommended that, wherever possible, such
penetrations are avoided. In other cases, rated proprietary
sealants and products should be used.
There is a wide range of services and materials that may
be required to penetrate sound rated walls and ceilings,
and in varied configurations and concentrations. CSR
recommends that an acoustic engineer be consulted for
advice on all details for projects with specific acoustic
objectives.
Fire and acoustic rated switch boxes are available from
manufacturers such as PROMAT, CLIPSAL and HPM to
assist in maintaining the acoustic integrity of wall systems.
Wall system CSR 075 has been tested without penetrations,
and also in the configuration shown in FIG Z201, using
PROMAT fire rated switch boxes. An acoustic performance
of Rw52 was recorded in both cases. (CSIRO Nth Ryde Test
N HAS 029). Designers should contact the manufacturer
for performance in other walls and configurations. CSR
recommends that wherever electrical penetrations are
made, 75mm CSR Bradford Glasswool Partition batts be
incorporated in the wall cavity to assist acoustic integrity.
Refer to FIG Z201 & Z203.

As an alternative to fire and acoustic rated power boxes,


standard power points can be installed using the Gyprock
Silencer. This reduces the labour intensive cutting and
caulking requirements of many other systems. Refer to FIG
Z202.
The acoustic performance of four power points back to
back in CSR 295(b) was evaluated by testing at CSIRO
and no reduction in Rw occurred up to Rw 60. Refer to FIG
Z204.
Plumbing penetrations such as taps and shower roses in
walls can also be contained in the Gyprock Silencer. This
can maintain the acoustic separation of the wall as above,
and provides effective rating of plumbing noise to adjacent
areas. Refer to FIG Z205.

FIG Z201: ACOUSTIC TEST CONFIGURATION USING


FIRE RATED SWITCH BOXES
Fire rated Switch Boxes
(Test conducted with
Fyreguard electrical
switch boxes)

75mm Bradford Glasswool


Partition Batts

2 x 13mm GYPROCK FYRCHEK


plasterboard each side of 64mm steel
studs at 600mm centres

FIG Z200: GOOD ACOUSTIC DESIGN PRACTICE FOR SERVICES


Concrete Slab
Water supply

Gyprock
Silencer

Gyprock
Silencer

Gyprock
Silencer

Where possible, run plumbing


services vertically from outlets
into ceiling or floor space

Mixer
only

Water supply

The Red Book

Concrete Slab

Power supply

Z17

For bulkhead and ceiling systems to protect against


noise generated by services, refer to Section F Service
Systems. These systems may incorporate a number of
standard downlights equally spaced over any 5m2 area.
Where a higher concentration of downlights is required,
sound rated downlights such as Regal R1012/FRD can
be used. Designers should contact the manufacturer for
performance and installation details. Refer to FIG Z224.

FIG Z203: TYPICAL POWER OUTLET/LIGHT SWITCH


INSTALLATION USING FIRE RATED SWITCH BOX
Stud

Fire Rated Switchbox


Seal cable penetration as
per switch box
manufacturers requirements
Seal around cutout
with CSR Gyprock
Fire Mastic

FIG Z202: GYPROCK SILENCER

CSR Bradford Insulation


(recommended to assist
acoustic integrity of wall
system)

Deflection
gap

Silencer inside
track and held by
Rondo clip

GYPROCK FYRCHEK
plasterboard (number of
layers and thickness in
accordance with wall
system specifications)

Head
Track

Fire Performance

Gyprock
Silencer

Service penetrations in fire rated walls and ceilings that


can be effectively rated include electrical and data cables,
switches and GPOs, hydraulic pipes, vents and mechanical
ducts. Access panels and control joints can also be installed
with appropriate fire resistance levels.
Power outlets and light switches can be installed in fire
rated walls using either fire rated switch boxes or with
standard switches within a Gyprock Silencer . When
installed correctly, these methods can maintain the FRL of
the wall system in which they are installed.

Base Track
or Angle

Gyprock
Silencer

Screw fix Gyprock Silencer


to base track or angle

50mm

200mm

50mm

The fire resistance of electrical penetrations was tested at


the CSR Research NATA Laboratory. Standard power points
were positioned back to back within Gyprock Silencers
without degrading the fire resistance of the wall system up
to /120/120. (CSIRO assessment FCO 2039). Taps and
similar plumbing penetrations can also be installed in the
Silencer for the same rating.
Where fire and acoustic rated switch boxes are specified,
refer to the manufacturer for appropriate products and
installation details.
Metal pipe penetrations may be treated as per BCA
deemed-to-satisfy details or in accordance with a
proprietary assessed detail. These details typically involve
mastic sealants. Plastic pipes, and pipes with insulation
lagging, are usually treated with fire collars in accordance
with manufacturers details, in both walls and ceilings.
Some assessed details and typical details for proprietary
treatment of penetrations are included. Additional
information can be found in relevant Gyprock installation
manuals, and refer to the appropriate product manufacturer.

Z18

The Red Book

Penetration Details
FIG Z204: TYPICAL ELECTRICAL SERVICES
INSTALLATION WITH GYPROCK SILENCER

FIG Z206: PIPE PENETRATION THROUGH WALL


(Up to FRL /120/. Appraisal: WRFA C91409)

Up To FRL /120/120. Appraisal: FCO 2039

GYPROCK
Plasterboard CD

General purpose
power outlet
CSR Gyprock
Fire Mastic
thickness 15mm
min.

Where wall
system has only
one layer of
GYPROCK
FYRCHEK,
provide extra
200mm wide
border and fix
with laminating
screws

20mm

25mm
150mm max.

Gyprock
SecurityWall
Panel

CSR Gyprock
Fire Mastic

GYPROCK FYCHECK
Plasterboard

Gyprock
Silencer

Steel or copper
metal pipe
system, 1.5mm
min. wall
thickness
2 layer
GYPROCK
FYRCHEK
wall system

FIG Z205: TYPICAL PLUMBING SERVICES


INSTALLATION WITH GYPROCK SILENCER
Up To FRL /120/120. Appraisal: FCO 2039
10mm GYPROCK plasterboard
strip (600 x 200mm) to one side.
Screw fix to Silencer, centered
on penetration with screws at
300mm centres.
Omit for FRL /90/90

GYPROCK
FYCHECK MR
Plasterboard

FIG Z207: ACCESS PANEL IN WALL

Wall studs and noggings


around cutout

Fire rated access


panel installed to
manufacturers
details

One layer 16mm


GYPROCK FYRCHEK
fixed to studs and
noggings around cutout

GYPROCK
AQUACHEK
plasterboard

The Red Book

Mixer
tap set

Gyprock
Silencer

GYPROCK FYRCHEK
fixed to studs and
noggings around cutout
at 150mm maximum
centres

Set over stopping bead


around opening

Z19

FIG Z208: CABLE TRAY AND CABLES

FIG 210: TYPICAL PVC PIPE PENETRATION

FRL /120/120. Appraisal: FSP 0087 (PROMAT)

Refer to manufacturer for assessment number and installation details.


GYPROCK
Plasterboard
wall with
required fire
rating

GYPROCK
FYRCHEK

Electrical
Cables

Cable
Tray

PVC pipe

CSR Gyprock Fire


Mastic 3mm
minimum thickness
and 30mm overlap
on board face
16mm

Proprietary
Fire Collar

IBS strips
50 x 19mm

16mm

16mm

CSR Gyprock Fire Mastic


overlapping face of board
minimum 30mm around
penetration

FIG 211: TYPICAL PVC PIPE PENETRATION RETROFIT


FIRE COLLAR

16mm

Fill all gaps with CSR


Gyprock Fire Mastic

Refer to manufacturer for assessment number and installation details.


Fire rated wall
to system
specification
Fire rated
sealant as per
system
specification

PROMAT
Fyre Collar
fixed to support
framing

GYPROCK
FYRCHEK
wall lining

Cable Tray

PVC Pipe

PROMAT
Fyre Collar
fixed to support
framing

IBS strips
50 x 19mm

FIG Z209: CABLING (UP TO 3 CORE + EARTH)


FRL /120/60. Appraisal: WFRA C91409
Where wall system has only
one layer of FYCHEK, provide
extra 200mm wide border and
fix with laminating screws
25mm

25mm

GYPROCK
FYRCHEK
1 or 2
layers

10-30mm
CSR Gyprock
Fire Mastic

Z20

The Red Book

Fire Damper Penetrations in Walls


Detail FIG Z212 is suitable for dampers rated up to FRL /120/. Duct weight must not be supported by the wall. For full
specifications and installation details, refer to the appropriate damper manufacturer.

FIG Z212: INSTALLATION DETAIL FOR FIRE DAMPER IN STUD WALL SYSTEM
Appraisal: PROMAT FCO 2106
Boxed studs
Deflection Head
Track fixed to studs
Promaseal IBS backing
rod 20% larger diameter
than gap (gap 15-30mm).
Promaseal Acrylic Mastic
over (5mm min. depth)

Caulk between
plasterboard and
damper body sides
with Promaseal
Acrylic Mastic 5mm
min. depth

Mechanical fire
damper tested and
approved for
AS1530.4

1 or 2 layers
GYPROCK
FYRCHEK
Plasterboard as
per FRL
Damper seal angles
75 x 50 x 1.2mm MS
Boxed studs

Deflection Head
Track fixed to studs

FIG Z213: INSTALLATION DETAIL FOR LORIENT LVH44 FIRE DAMPER


FRL /120/. Appraisal: FCO 1869/2276 LORIENT
Ductwork branch
mechanically fixed to
sheetmetal riser with
rivets or tek screws

CSR Gyprock Laminated


Service System
Duct breakaway connection
in accordance with AS1682.2

Perimeter of fire damper


sealed with Lorient
Intumescent Mastic

Lorient LVH44 Intumescent Fire


Damper unit (nom. 300 x 300mm)

Sheetmetal
Riser
Sheetmetal ductwork
Perimeter of duct sealed with
Lorient Intumescent Mastic

The Red Book

Z21

FIG Z214: INSTALLATION DETAIL FOR FIRE DAMPER IN SHAFT WALL SYSTEM
FRL /120/. Appraisal: CSIRO FCO 2109

1500mm max.

J-Track fixed to studs

Promaseal IBS backing


rod 20% larger diameter
than gap (gap 15-30mm)

J-Track
Mechanical fire
damper tested and
approved for
AS1530.4

10mm dia. MS rod


fixed to slab and
support angle

1400mm max.

Damper seal angles


75mm x 50mm x
1.2mm MS

Support angle 50mm


x 50mm x 5mm MS
1 or 2 layers GYPROCK
FYRCHEK Plasterboard
as per FRL
GYPROCK Shaft
Liner Panel

FIG Z215: TYPICAL INTUMESCENT FIRE DAMPER


Refer to manufacturer for assessment number and installation details.

Steel studs
at 600mm
centres

Rondo angles
mechanically
fixed to studs

GYPROCK
FYRCHEK
plasterboard

Steel studs at
600mm centres

Proprietary
intumescent
damper

Spigot to terminate
with break joint

Perimeter gaps sealed


Steel studs
at 600mm
centres

Z22

The Red Book

FIG Z216: TYPICAL FIRE HATCH IN CEILING

FIG Z219: BACK-BLOCKING OF ELECTRICAL


PENETRATION ON CEILING
FRL 60/60/60. Appraisal: FCO 0609

Ceiling Joists/Trimmers around


all sides of opening
Fire rated access panel installed
to manufacturers specifications

Two 100 x 100mm


blocks of 16mm
GYPROCK
FYRCHEK

Ceiling cut-out equal


to hatch frame size
GYPROCK FYRCHEK
plasterboard ceiling lining

Recess 1st block


to accommodate
wiring

FIG Z217: TYPICAL AIR CONDITIONING DAMPER TO


CEILING
Refer to manufacturer for assessment number and installation details.
AC Duct and Damper
supported independently
to ceiling system

Ceiling
suspension
system

FIG Z220: RECESSED LIGHT CAVITY IN TIMBER FRAME


FRL 60/60/60. Appraisal: FCO 0609
Timber flooring

Fire Damper
Floor Joist

Fire Damper
Frame

GYPROCK FYRCHEK
plasterboard layers
and thickness
appropriate for system

Trimmers
50 x 50mm min.

Top Cross Rail


Part N128

Air Diffuser
Volume Dampers

Furring Channel
Part N129

1 or 2 layers of GYPROCK
FYRCHEK plasterboard

FIG Z218: PROMAT FIRE SPRING CEILING


INSTALLATION.
60 minutes RISF. Appraisal: WRFA C91409

FIG Z221: RECESSED LIGHT BOX IN SUSPENDED


STEEL FRAME CEILING
FRL 60/60/60. FCO 0609
(*Components not supplied by CSR)
CSR Gyprock
Fire Spring
*Protection box
CSR Gyprock
Fire Mastic

Stirrup fabricated
from stud or furring
*Cup head bolts and N226 clips
85 x 7mm
*Light fitting
support
450mm

141mm

127mm

50 50

7mm
Two layers
16mm
GYPROCK
FYRCHEK

*Support
250 x 50 x 3mm

285mm

2 layer x 16mm
GYPROCK FYRCHEK

*Light trim

The Red Book

Z23

FIG Z222: COPPER PIPE PENETRATION THROUGH


CEILING.

FIG Z225: HANDRAIL ATTACHMENT

PROMAT. FRL 60/60/60. Appraisal: WRFA 1606

Wall Studs

IBS Strip
50 x 20mm

Timber
support
plate

520mm high
wire mesh
Shield,
200mm
diameter

1, 2 or 3 layers
of GYPROCK
FYRCHEK
plasterboard

6mm
15mm min.

100mm max.

Gyprock Fire
Mastic

GYPROCK Fyrchek lining


to system requirements

Wafer head
screw

Fix with max. 10g


screws to timber
support plate

Hand rail or similar light


weight attachment

FIG Z226: HANDRAIL ATTACHMENT ALTERNATIVE


METHOD
FIG Z223: TYPICAL PVC PIPE PENETRATION
THROUGH CEILING

Wall Studs

Installation must be to fire rated collar manufacturers specifications.


Timber
support
plate
Additional support
framing if required

Rondo Nogging
Bracket No.501

PVC Pipe

Wafer head
screw

Fix with max. 10g


screws to timber
support plate

GYPROCK Fyrchek lining


to system requirements

Hand rail or similar light


weight attachment

1, 2 or 3 layers
of GYPROCK
FYRCHEK
plasterboard
Fire collar
fixed to
support
framing

FIG Z224: TYPICAL FIRE RATED DOWNLIGHT

Z24

The Red Book

Section IN
Index

Contents
Index to Systems

The Red Book

IN2 IN3

IN1

Index to System Numbers


System N

Page N

System N

Page N

System N

Page N

System N

Page N

System N

Page N

005

B9

126

B43

248

B36

362

C13

535

D15

010

B9

127

B43

249

B36

363

C13

540

D12

011

B9

128

B43

250

B17

364

C13

541

D12

015

B9

129

B43

255

B18

368

C14

542

D12

025

B9

131

B14

257

E16

369

C14

543

D12

032

B9

132

B15

258

E16

370

C14

544

D13

033

B10

135

B14

259

E16

371

C14

545

D13

035

B10

136

B34

260

E16

372

C14

548

D12

038

B11

137

B34

261

E16

375

C9

549

D13

039

B10

138

B34

262

E16

380

C9

550

C10

040

B11

139

B34

263

E17

386

C20

551

D13

043

B13

140

B35

264

E17

387

C20

553

C10

044

B13

141

B35

265

E17

388

C20

555

C10

045

B13

142

B35

266

E17

389

C20

556

C11

046

B13

143

B35

267

E17

390

C21

557

E22

048

B13

150

B15

275

B19

391

C21

559

E22

049

B13

152

B15

280

B19

392

C21

560

E22

050

B11

153

B15

284

B27

393

C21

561

E22

055

B11

155

B15

285

B27

403

C18

562

E22

060

B28

165

B40

290

B25

406

C18

563

E23

061

B28

166

B39

291

B25

407

C18

564

E23

062

B28

167

B40

292

B25

410

C18

565

E23

065

E31

168

B40

293

B25

411

C18

566

E23

066

E31

170

B41

294

B26

414

C19

567

E23

067

E31

171

B41

295

B26

415

C19

575

C12

068

E31

175

B16

296

B27

419

C19

579

C11

069

E31

178

B41

297

B26

422

C15

580

C12

070

E32

179

B41

298

B27

425

C15

582

C12

071

E32

180

B16

305

C6

430

C16

600

B10

072

E32

184

B45

310

C6

450

C16

601

B10

073

E32

185

B45

311

C6

455

C16

605

B10

075

B12

186

B45

315

C6

457

E20

606

B11

080

B12

187

B45

320

C6

458

E20

610

B12

085

B30

192

B46

322

C6

459

E20

611

B12

086

B30

193

B46

325

C7

460

E20

613

B12

089

B30

195

B46

326

C7

461

E20

614

B12

090

B30

196

B46

327

C7

462

E20

615

B11

091

B30

204

B17

330

C7

463

E21

630

B15

092

B31

206

B18

335

C7

464

E21

631

B14

093

B31

207

B17

337

E18

465

E21

632

B14

100

B23

208

B17

339

E18

466

E21

652

C9

101

B23

212

B19

340

E18

467

E21

653

C8

102

B23

216

B19

341

E18

475

C17

660

C8

103

B23

217

B18

342

E18

480

C17

661

C15

110

B14

218

B18

343

E19

493

C31

662

C15

111

B24

222

B20

344

E19

494

C31

663

C16

113

B24

223

B20

345

E19

496

C31

664

C16

114

B24

225

B20

346

E19

498

C31

665

C9

115

B24

226

B20

347

E19

526

D14

666

C16

118

B42

230

B21

350

C8

527

D14

667

C9

119

B42

231

B21

352

C8

528

D15

670

C17

120

B42

235

B21

354

C7

530

D14

671

C17

121

B42

240

B22

354

C8

531

D14

672

C17

122

B42

241

B22

355

C8

532

D14

674

C10

123

B42

243

B22

360

C13

533

D14

675

C10

125

B14

244

B22

361

C13

534

D15

677

C10

IN2

The Red Book

System N

Page N

System N

Page N

System N

Page N

System N

Page N

System N

Page N

678

C11

816

E9

876

E27

680

C11

817

E9

877

E33

959

E18

FP62

G14

967

B33

FP63

681

C11

818

E9

878

G14

E33

968

B33

FP75

682

C11

819

E9

G15

880

E33

969

B33

FP80

690

C28

820

G16

E7

885

E8

970

B32

FP82

693

C28

G16

821

E10

886

E8

971

B32

FP84

694

G17

C29

822

E11

888

E8

977

B32

FP86

G17

695

C29

823

E10

890

E37

981

E34

FP88

G18

696

C28

824

E10

891

E30

982

E34

G17

697

C29

825

E11

892

E30

983

E34

698

C29

826

E11

893

E30

985

E34

722

D20

827

E11

894

E30

986

E34

723

D20

828

E11

896

E30

987

E35

724

D20

829

E11

898

E30

992

E35

730

D19

831

E12

900

C22

993

E35

731

D19

832

E12

901

C22

994

E35

732

D19

833

E12

902

C24

995

E35

FP90
HEBEL
1000/1001
HEBEL
1006/1007
HEBEL
1030/1031
HEBEL
1032/1033
HEBEL 1302

E35

HEBEL 1303

D18

B52

HEBEL 1304

D18

B48

HEBEL 1305

D18

B48

HEBEL 1306

D18

HEBEL 1400

C25

737
738
739
760

D6
D8
D8
D6

834
835
836
837

E12
E13
E13
E13

903
905
905
906

C24
C24
C30
C22

997
EC031
EC105
EC110

D16
D17
D16
D17
D18

761

D6

838

E13

906

C24

EC115

B48

762

D6

839

E13

907

C22

EC205

B49

Hebel 1404

B44

B49

HEBEL 1600

E36
E36

763

D7

841

E14

908

C22

EC210

764

D7

842

E26

909

C22

EC215

B49

HEBEL 1635

765

D7

843

E26

911

C23

EC220

B50

SS01

F4

766

D7

844

E27

912

C23

EC225

B51

SS02

F4

767

D8

845

E14

920

C26

EC230

B51

SS04

F4

768

D8

846

E14

921

C27

EC305

B48

SS08

F5

769

D8

847

E15

923

C26

EC310

B49

SS10

F5

774

D9

848

E15

924

C26

EC315

B49

SS11

F5

775

D9

849

E15

925

C26

EC320

B50

SS12

F5

776

D10

850

E28

927

C26

EC325

B51

SS13

F5

777

D10

851

E28

928

C27

EC605

B48

SS17

F5

778

D11

852

E28

932

B39

EC615

B49

SS18

F6

779

D11

853

E28

933

B38

EC620

B48

SS19

F6

780

D9

854

E28

934

B38

FP01

G3

SS20

F6

781

D9

855

E29

935

B39

FP02

G3

SS21

F6

783

D10

856

E29

936

C30

FP03

G4

SS22

F6

784

D10

857

E29

937

B44

FP04

G4

SS23

F6

787

D11

858

E29

940

B37

FP10

G5

SS30

F7

788

D11

859

E29

941

B37

FP11

G5

SS31

F7

795

D21

860

E31

941

B37

FP16

G6

SS32

F7

796

D21

862

E26

945

B29

FP17

G6

SS34

F7

797

D21

863

E26

946

B29

FP20

G7

SS38

F7

798

D21

864

E26

947

B29

FP21

G7

SS39

F7

805

E7

865

E33

948

E24

FP25

G8

SS40

F8

806

E7

866

E33

949

E24

FP26

G8

SS41

F8

807

E7

867

E27

950

E24

FP31

G9

SS42

F8

808

E7

868

E26

951

E24

FP35

G9

SS44

F4

809

E7

870

E25

952

E24

FP40

G10

SS45

F4

810

E8

871

E25

953

E24

FP45

G10

SS46

F4

811

E8

872

E33

954

E25

FP50

G11

812

E8

873

E33

955

E25

FP55

G12

814

E9

874

E27

956

E25

FP60

G13

815

E9

875

E27

958

E22

FP61

G13

The Red Book

IN3

GYP500 | November 2011

The Red Book

Health & Safety

Contact Details

Information on any known health risks of our products and


how to handle them safely is on their package and/or the
documentation accompanying them.

CSR Gyprock Web Site

Additional information is listed in the Material Safety Data


sheet. To obtain a copy, telephone 1800 807 668.

Disclaimer
This guide is current at September 2011 and supersedes
all previous versions of the Fire and Acoustic Design Guide.
CSR has taken all reasonable care in producing this guide,
however CSR makes no representations or warranties,
express or implied, as to the accuracy, reliability or
completeness of the guide, and disclaims all liability, direct
or indirect (and whether or not arising out of the negligence,
default or lack of care of CSR) for any loss or damage
(whether foreseeable or not) suffered by the recipient or
any other person arising out of, or in connection with, any
use or reliance by any of them on the guide. Liability which
cannot legally be excluded is limited to the maximum extent
possible.
Information including acoustic and fire rating has been
sourced from recognised third parties and is current at
the time of printing. Systems, Standards and Building
Codes are subject to change. To ensure the information
is current, check the websites www.gyprock.com.au and
www.cemintel.com.au or contact CSR.
The guide is copyright CSR Limited (A.B.N 90 000 001 276)
and its related bodies corporate (CSR). Copyright 2011.

www.gyprock.com.au
CSR Cemintel Web Site
www.cemintel.com.au
CSR Gyprock Sales Support
Telephone: 13 17 44
Facsimile: 1800 646 364
CSR designLINk Technical Support Service
Telephone: 1800 621 117
Facsimile: 1800 069 904
Email: designlink@csr.com.au
New South Wales and ACT
376 Victoria Street, Wetherill Park NSW 2164
Queensland
768 Boundary Road, Coopers Plains QLD 4108
Victoria
277 Whitehall Street, Yarraville VIC 3013
South Australia
Lot 100 Sharp Court, Mawson Lakes SA 5095
Western Australia
21 Sheffield Road, Welshpool WA 6106
Tasmania
PO Box 61, Glenorchy TAS 7010
Northern Territory
Cnr Stuart Hwy & Angliss St, Berrimah NT 0828

The following are trade marks of CSR Limited and are under license. CSR,
Gyprock, Supaceil, Soundchek, Aquachek, Impactchek, Superchek,
Fyrchek, FyrchekMR, ECO8, Bradford, designLINK, Cemintel,
SeminSeal, RendaLine, StrataWall, ExpressWall.
Publication GYP500.BMS9600.1111

Você também pode gostar