SN
1
2
DISCRIPTION
KVA Rating
Input
600 VA to 3 KVA
Nominal:
Variation:
12 to 48 V D.C
Frequency Variation
5
6
7
8
9
Topology.
Efficiency
Isolation between Input to output
PWM Switching Frequency
Output Distortion
10
11
EMI / RFI
12
No Load Current
750mA to 1Amp
DISCRIPTION
30 Amp
12 to 48 V
21 V Per Batt
> 98%
COMPLETE SYSTEM
o
o
o
o
o
o
o
Protection
Display
Operating Temperature
o Input Voltage
o Output Voltage
o Load Percentage
o Battery Voltage
o Solar Generation(In Wattage)
o Load on inverter/UPS
0C to 50C
Storage Temperature
-20C to 80C
< -60 db
1. Between 12V to 14V, the battery is charged using the Solar Supply (if present), even if the Mains
is present. The load is on Mains in this mode.
2. When the battery voltage reaches 14.2V, the unit switches over to the Inverter mode, charging
continues from the solar supply and the load gets shifted from Mains to the Battery(the INV ON
indicator lights up) , even if the Mains is present (the Mains Indicator starts flashing to show the
presence of Mains). The unit is then supposed to have entered into SOLAR ZONE. In this zone,
the solar energy stored in the battery is utilized, saving the electricity.
3. At battery voltage 14.2 V, the charging(either from Solar or from Mains) stops, then starts again
when it falls down to 13.8V(when Solar present), again stops at 14.2 V. This is the trickle
charging operation.
4. If Mains supply cuts off during the solar zone, the unit maintains its solar-zone mode.
Therefore, when the Mains supply resumes, the unit continues to operate in Inverter mode and
the load is supplied by the battery.
5. When the battery voltage reaches 11.5V per battery during the solar zone, the unit switches
back to the Mains Supply, the charging continues from solar supply and the load gets shifted
back on Mains Supply.
6. When Mains & Solar Power both are not available inv will start working on battery mode
7. When the battery voltage is below 10.5V, the unit enters a shut down.
Our Solar Inverter System which include Indian Panel, Solar/Tubular Battery, Battery Tray,
Surge Protector, Solar Inverter, Charger Controller, Automatic Change over, Solar/Grid Charger
Selection etc....
The wattage of panels and battery capacity will be determined with consultation of the customer
and again depend on type of usage.
The design of solar inverter system it is not a one line answer hence a discussion is required. so
you may contact with your requirement so that we can design your system Our range is also
customized as per clients specification and delivered within stipulated time.