1
2

DISCRIPTION
KVA Rating
Input

600 VA to 3 KVA
Nominal:
Variation:

12 to 48 V D.C

Frequency Variation

50Hz +/- 0.1 % (Crystal controlled)

Output Voltage Regulation

+/- 2 % for total input variation range & No load


to full load

5
6
7
8
9

Topology.
Efficiency
Isolation between Input to output
PWM Switching Frequency
Output Distortion

True Sine Wave Off-Line


>85%
500VDC for 1 Min
24Khz
< 5% for any type of load

10

Total power Factor

0.8 lag to 0.8 lead

11

EMI / RFI

As per International Standard for the Subsequent


Clause

12

No Load Current

750mA to 1Amp

ZERO DROP SOLAR CHARGE CONTROLLER:


SN

DISCRIPTION

Charger Amp Rating

30 Amp

Nominal battery Voltage

12 to 48 V

PV Open Circuit Voltage

21 V Per Batt

Charging Regulation Methods

Boost & Float

Power Conversion Efficiency

> 98%

COMPLETE SYSTEM
o
o
o
o
o
o
o

Protection

Battery Under Voltage


Battery Over Voltage
Mains Input Under Voltage
Battery Reverse(Optional)
Mains Input Over Voltage
Output short Circuit
Output Over Voltage

Display

Operating Temperature

o Input Voltage
o Output Voltage
o Load Percentage
o Battery Voltage
o Solar Generation(In Wattage)
o Load on inverter/UPS
0C to 50C

Storage Temperature

-20C to 80C

Overall Audio able Noise

< -60 db

Bill Reduction Protocol (BRP) for Solar Inverters


Considering the need of the Indian Customers, Kripa Solar Inverters have introduced a unique feature of
the Inverter Battery Power Management using a specific pattern of electricity utilization from Solar
Panel and Mains Supply Lines.
This pattern is developed after rigorous surveys conducted across the country, both in rural and urban
areas, to understand the power demands, availability of electricity supply and average solar energy
available from moderately efficient solar panels.
The protocol thus developed, when bundled with the Pure Sine wave Inverters, renders a major benefit
to the customer in achieving considerable reduction in his electricity bill.
What follows is a brief explanation of this protocol:
When the single battery voltage is between 10.5 V to 12 V, the inverter unit selects the Mains or Solar
Power as the source of charging.
Even if the Mains supply is available. But solar power is strong inv will charge batteries on solar only &
the load is connected to the Mains (if present) in this mode.

1. Between 12V to 14V, the battery is charged using the Solar Supply (if present), even if the Mains
is present. The load is on Mains in this mode.

2. When the battery voltage reaches 14.2V, the unit switches over to the Inverter mode, charging
continues from the solar supply and the load gets shifted from Mains to the Battery(the INV ON
indicator lights up) , even if the Mains is present (the Mains Indicator starts flashing to show the
presence of Mains). The unit is then supposed to have entered into SOLAR ZONE. In this zone,
the solar energy stored in the battery is utilized, saving the electricity.

3. At battery voltage 14.2 V, the charging(either from Solar or from Mains) stops, then starts again
when it falls down to 13.8V(when Solar present), again stops at 14.2 V. This is the trickle
charging operation.

4. If Mains supply cuts off during the solar zone, the unit maintains its solar-zone mode.
Therefore, when the Mains supply resumes, the unit continues to operate in Inverter mode and
the load is supplied by the battery.

5. When the battery voltage reaches 11.5V per battery during the solar zone, the unit switches
back to the Mains Supply, the charging continues from solar supply and the load gets shifted
back on Mains Supply.
6. When Mains & Solar Power both are not available inv will start working on battery mode
7. When the battery voltage is below 10.5V, the unit enters a shut down.

Our Solar Inverter System which include Indian Panel, Solar/Tubular Battery, Battery Tray,
Surge Protector, Solar Inverter, Charger Controller, Automatic Change over, Solar/Grid Charger
Selection etc....

The wattage of panels and battery capacity will be determined with consultation of the customer
and again depend on type of usage.
The design of solar inverter system it is not a one line answer hence a discussion is required. so
you may contact with your requirement so that we can design your system Our range is also
customized as per clients specification and delivered within stipulated time.
At last but not least only genuine buyer's please
Kripa Solar Inverter UPS
Punalur & Cochin
Phone +91 475 2230926
Mob: +91 94470 95128
Email: kripainverterups@gmail.com
Website: www.kripainverterups.com

Você também pode gostar