Você está na página 1de 13

eNodeB commissioning guide (LMT)

1. LMPT- Connect the ethernet cable on your laptop


NIC and the other end on the LMPT, ETH port.

OR
UMPT- Connect the ethernet cable on your laptop
NIC and the other end on the RJ45-to-USB
adapter then the other end of the adapter on the
UMPT, USB port.

2. Configure your laptops IP


- Your IP address should be in the same subnet
as the eNodeBs Local Maintenance IP
(192.168.0.49 mask 255.255.255.0)
- E.g. 192.168.0.50

By Alan Letswele

3. Login the eNodeB using the LMT


- Open your web browser and on the address
bar type in the eNodeBs Local Maintenance IP
(192.168.0.49)
- User Name: admin
- Password: hwbs@com
- Enter the Verify Code as it apears on the right
side of the text box.

By Alan Letswele

4. Click on the MML tab.

5. Check the software version.


- Command: LST VER
- Current software version must be
V100R005C00SPC340

By Alan Letswele

6.Saving the eNodeB scripts in your PC


- Create a folder on your desktop
- Download and save the eNodeB script in the
folder you just created.
- Rename the eNodeB configuration data file
(script) to LMT.XML
7. Configure your FTP server as follows. If you

dont have it then double click and run this


SFTPServer.exe

file:
- User name: admin
- Password: admin
By Alan Letswele

- Working directory: (path to the folder where you


saved the eNodeB script)

8.Download the configuration script into the


eNodeB
-

Command: DLD CFGFILE


IP Mode: IPV4(IPv4)
Server IP: 192.168.0.50
FTP user name: admin
FTP password: admin

By Alan Letswele

9.Activate the CFGFILE


- Command: ACT CFGFILE
- Effect mode: IMMEDIATELY

By Alan Letswele

- After this the eNodeB is going to reset and you


will be logged out of the LMT. Login again!

10.
Confirm that the CFGFILE was
successfully activated
- Command: LST ENODEB
- Confirm that the eNodeB ID and the eNodeB
name are the same as the ones on the planned
data

By Alan Letswele

Check transmission

11.
-

Command: DSP S1INTERFACE


S1Interface State must be NORMAL!
S1 SCTP Link State must be NORMAL!
If any of the above is ABNORMAL please
contact your support engineer.

By Alan Letswele

12.

Check the OML (Operation and

Maintenance Link)
- NB: If the OM Channel status is Abnormal
then the OML is DOWN. Contact the OMC
engineer for assistance

By Alan Letswele

13. Check GPS antenna State


- DSP GPS
- The GPS card state must be Normal
- The number of GPS antennas traced must be
greater than 4!
- If either one of the two above statements is
not so then contact the support engineer for
troubleshooting.

14. Loading the License


-

If OM is UP then run this command:


INS
LICENSE:DIR="/export/home/backup/ne/eNodeB/License",FN="Demo_LTE_V100R005_ALL_2
0120910.dat",FLG=YES,MODE=IPV4,IP="10.148.18.134",USR="root",PWD="root";

If OM is NOT UP then follow the below


procedure:

- Save this file in a folder on your PC

Demo_LTE_V100R005_ALL_20120910.dat

By Alan Letswele

- Command: INS LICENSE


- Directory name: (Directory path where you
saved this file)
- File name:
Demo_LTE_V100R005_ALL_20120910.dat
- Force flag: YES
- IP mode: IPV4(Pv4)
- FTPServer IP: 192.168.0.50
- User name: admin
- User password: admin

15. LTE RET configuration


LTE - RET CONFIGURATION SCRIPT.txt

******************************************************************************************
*********************** RET Configuration data file loading ********************************
******************************************************************************************
!!! PREREQUISITE(S)
- OM must be UP
!!! INSTRUCTIONS
-

COPY AND PASTE THIS ON YOUR LMT AND RUN (F9)


DO IT ONE COMMAND AT A TIME
WHEN ALL COMMANDS ARE SUCCESSFUL, CALIBRATE THE RETs (CLB RET)
SET RET TILTS
VERIFY (DSP RETSUBUNIT)

---------------CHOOSE ONLY ONE WHICH MATCHES WITH THE TARGET HARDWARE PLEASE--------------//ANDREW'S (TRIBAND and SINGLEBAND) ANTENNA
DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=0,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/HWXXX-6516DS-VTM.dat";
DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=1,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/HWXXX-6516DS-VTM.dat";
DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=2,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/HWXXX-6516DS-VTM.dat";
//AGGISON FOUR PORT (SINGLE BAND) ANTENNA

By Alan Letswele

DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=0,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/Aggisson 4 ports.bin";
DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=1,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/Aggisson 4 ports.bin";
DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=2,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/Aggisson 4 ports.bin";
//AGGISON TWO PORT (SINGLE BAND) ANTENNA
DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=0,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/Aggisson 2 ports.bin";
DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=1,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/Aggisson 2 ports.bin";
DLD
RETCFGDATA:OPMODE=SUBUNIT,DEVICENO=2,SUBUNITNO=1,IP="10.148.18.134",USR="root",PWD="root
",SRCF="/Aggisson 2 ports.bin";

LTE Site Commission Self-check Report (Date:2012-09-22)


Checking Engineer:

Site Name:
N
Item
o
Software and License
1
Status Check

Configuration Check

Transmission
Configuration
Transmission Status

Description
Version Check
License Check
Site name is same as
planed?
Site ID is same as planed?
Cell name is same as
planed?
Cell ID is same as planed?
PCI is same as planed?
Cell Downlink earfcn is
same as planed?
Cell Root sequence index
is same as planed
Cell TAC is same as
planed?
Devip Ip is the same as
planed?
Route is the same as
planed?
Control plan and User plan
normal or abnormal?

MML Command for Check


LST VER:;
LST LICENSE:;
LST ENODEB:;

LST CELL:;

LST CNOPERATORTA:;
LST DEVIP:;
LST IPRT:;
DSP
DSP
DSP
DSP

S1INTERFACE:;
SCTPLNK: SCTPNO=0
IPPATH: PATHID=0;
IPPATH: PATHID=1;;

By Alan Letswele

Resu
lt

RET
HardwareConfigurati
on and Status Check

Alarm Check and


Service Status Check

Info Record and Update


in iSite

DLD BINFile for different


Antenna and RCU type.

DLD RETCFGDATA:
OPMODE=SUBUNIT,
DEVICENO=0,
SUBUNITNO=1,
IP="10.149.104.43",
USR="ftpuser",
PWD="ftpuser",
SRCF="Correct BIN File
name according to
Antenna or RCU type";

Check RET Motor


Connection or Hardware

CLB RET: OPMODE=SITE;

RET Tilt&Azimuth is the


same as planed or not?

LST RETSUBUNIT:;
LST RETDEVICEDATA:;

RET Equipment Status


RET port status and
current value

DSP RET:;
DSP RETSUBUNIT:;

VSWR Threshold Change


to 1.5

MOD RRU: CN=0,


SRN=60, SN=0,
ALMTHRHLD=15;
MOD RRU: CN=0,
SRN=61, SN=0,
ALMTHRHLD=15;
MOD RRU: CN=0,
SRN=62, SN=0,
ALMTHRHLD=15;

eNodeB Alarm
check(Hardware and
Software Alarm)

LST ALMAF:;

All sectors VSWR are less


than 1.3?

STR VSWRTEST:;
DSP VSWR:;

Cell Status is normal or


abnormal?
Service test passed by
Supervior or not?
Update the info in iSite or
not?

DSP CELL:;
Info from Supervior on
site

PS:1.This checklist is based on the status that OMCH is ok and we can maintain the site from
M2000.
2.For site configuration check,you must have the planning data from Mars and compare
the planning data with the data inside the eNodeB
3.We must confirm that the eNodeB has no hardware alarm before the subcontractors
leave the site.

By Alan Letswele