HydraulicDesignManual:DesignFloodandCheckFloodStandards
Section6:DesignFloodandCheckFloodStandards
TxDOTsapproachtoselectingthedesignstandardforadrainagefacilityistouseareferencetablethat
specifiesarangeofdesignAEPsfordifferenttypesoffacilities.Table42providesthedesignfrequenciesfor
TxDOTprojects.Formosttypesoffacilitiesarangeofdesignfrequenciesispresented.Forthosetypesof
facilitieswitharangeofpossibledesignfrequencies,usuallyonedesignfrequencyintherangeis
recommended(indicatedbyanXwithsquarebracketsinTable42).Structuresandroadwaysshouldbe
serviceable(notinundated)uptothedesignstandard.
Table42:RecommendedDesignStandardsforVariousDrainageFacilities
DesignAEP
(DesignARI)
50%
20%
10%
4%
2%
(2yr)
(5yr)
(10yr)
(25yr)
(50yr)
Culverts
Bridges+
Culverts
[X]
Smallbridges+
[X]
Majorrivercrossings+
[X]
Functionalclassificationandstructuretype
Freeways(mainlanes):
Principalarterials:
Minorarterialsandcollectors(includingfrontageroads):
Culverts
[X]
Smallbridges+
[X]
Majorrivercrossings+
[X]
Culverts
Smallbridges+
Localroadsandstreets:
Offsystemprojects:
Culverts
Smallbridges+
FHWApolicyissameorslightlybetterthanexisting.
Stormdrainsystemsoninterstatesandcontrolledaccesshighways(mainlanes):
Inlets,drainpipe,androadsideditches
Inletsfordepressedroadways*
[X]
Stormdrainsystemsonotherhighwaysandfrontageroads:
Inlets,drainpipe,androadsideditches
http://onlinemanuals.txdot.gov/txdotmanuals/hyd/design_flood_and_check_flood_standards.htm
1/2
10/14/2016
HydraulicDesignManual:DesignFloodandCheckFloodStandards
Inlets,drainpipe,androadsideditches
[X]
Inletsfordepressedroadways*
[X]
Table42notes:
*Adepressedroadwayprovidesnowhereforwatertodrainevenwhenthecurbheightisexceeded.
[]BracketsindicaterecommendedAEP.Federaldirectivesrequireinterstatehighways,bridges,and
culvertsbedesignedforthe2%AEPfloodevent.Stormdrainsonfacilitiessuchasunderpasses,
depressedroadways,etc.,wherenooverflowreliefisavailableshouldbedesignedforthe2%AEPevent.
+Itmaybenecessarytocalculatethe4%(25yr),2%(50yr),0.5%(200yr),or0.2%(500yr)AEPfor
scourcomputations.SeetheTxDOTGeotechnicalManual.
Allfacilitiesmustbeevaluatedtothe1%AEPfloodevent.
Selectingadesignfloodisamatterofjudgmentitrequiresbalancingthefloodriskwithbudgetaryconstraints.
Whenconsideringthestandardforadrainagefacility,thedesignershouldfollowtheseguidelines:
Decideonthedesignstandardbyconsideringtheimportanceofthehighway,thelevelofservice,
potentialhazardtoadjacentproperty,futuredevelopment,andbudgetaryconstraints.
Developalternativesolutionsthatsatisfydesignconsiderationstovaryingdegrees.
Afterevaluatingeachalternative,selectthedesignthatbestsatisfiestherequirementsofthe
structure.
Consideradditionalfactorssuchasthedesignstandardsofotherstructuresalongthesamehighway
corridortoensurethatthenewstructureiscompatiblewiththerestoftheroadway.Alsoassessthe
probabilityofanypartofalinkofroadwaybeingcutoffduetoflooding.
Thedesignershoulddesignafacilitythatwilloperate:
Efficientlyforfloodssmallerthanthedesignflood.
Adequatelyforthedesignflood.
Acceptablyforgreaterfloods.
Inaddition,foralldrainagefacilities,includingstormdrainsystems,thedesignermustevaluatethe
performanceforthecheckflood(1%AEPevent).Thepurposeofthecheckfloodstandardistoensurethe
safetyofthedrainagestructureanddownstreamdevelopmentbyidentifyingsignificantrisktolifeorproperty
intheeventofcapacityexceedance.
Theintentofthecheckfloodisnottoforcethe1%AEPthroughthestormdrain,buttoexaminewherethe
overflowwouldtravelwhenthismajorstormdoesoccur.Forexample,thewatermaytraveldownthegutterto
thesamecreekastheoutfall,traveldownadrivewayanddirectlyintoahome,inundatethemainlanes,erodea
newdrainagepathtotheoutfall,orotherproblems.
Theexaminationofthecheckfloodshouldalsoincludeassessmentofthetailwater.Theremaybelocationson
theprojectthatarelowerthanthe100yearwatersurfaceelevation(ortailwater)ofthecreek.Thissituation
mayincreasethehydraulicgradelinethroughthestormdrainsystem,ormayevencausenegativeflow
throughthesystem.Thismaycauseblowoutswhichmayinturncauseanyofthesameproblemsasabove.
http://onlinemanuals.txdot.gov/txdotmanuals/hyd/design_flood_and_check_flood_standards.htm