BOILER PREFERENCES
Modern design
High efficient tubular exchanger „flue gas - water“
High combustion efficiency - up to 90% - low fuel
consumption - low production of emissions and ash
Wide output range of the manufactured boilers
15-45kW
Combustion of the soft and hard wood
Voluminous boiler hopper, which ensures longer
heating duration of one fuel portion
Possiblity to fire big wood logs
Minimum of waste
Easy attendance and simple cleaning
Automatic boiler stop after the fuel burn - out
Automatic control of the heat - up flap related with
opening and closing of the feeding door
Suction fan ensures continuos and efficient
combustion and dustfree operation
Continually modulated fan rotations
Equipped with the aftercooling circuit against
overheating of water in the boiler
High quality boiler steel of 8mm thickness is used
at boiler manufacturing
Refractory adapting pieces are heat resistant up
to the temperatures of 1350°C
The boiler fulfils criteria of the highest class under
the European norm EN303-5
ATTACK DPX
www.attack.sk
The wood gasifying boiler ATTACK DPX in the Standard, Profi and Lambda versions is intended for
economical and ecological heating of dwelling houses, cottages, small plants, work rooms and similar
objects. Prescribed fuel for the ATTACK DPX is dry wood. At full utilization of the feed hopper there is a
possibility of burning for 8 - 12 hours.
The ATTACK, s.r.o company as the largest Slovak manufacturer of heat technology, is specialized and
focused only on the heat technology of the following product lines:
- Floor standing solid fuel boilers - wood gasifying, pellet, universal
- Floor standing cast iron boilers
- Wall hung condensing boilers - with tank d.h.w. heating,
instantaneous d.h.w. heating, with possiblility of d.h.w. heating
in the external tank
- Wall hung atmospherical boilers -with tank d.h.w. heating,
instantaneous d.h.w. heating, with possiblility of d.h.w. heating
in the external tank
- Tanks for d.h.w. heating - directly and indirectly heated
- Accumulation tanks
- Solar technique
The ATTACK, s.r.o. company´s product portfolio is characterized by the wide assortment of the
ATTACK® products, classified by concrete product type, output and kind of fuel - solid fuel or biomass in
the nature of wood or wood pellets, natural gas, LPG-propane.
All the ATTACK, s.r.o. company´s products are manufactured under the trademark of ATTACK® and they
belong to the top of their class.
With their parameters, high efficiency and low negative effect to the enviroment, they reach parameters of the
best European products.
The ATTACK, s.r.o. company is the holder of the quality certificate ISO 9001 for manufacturing, service,
namagement and development of boilers. All the products are approved and tested
by the CE and GOST certificates.
The ATTACK, s.r.o. company achieved plenty of awards
by aggregate committee of specialists - from honourable
mentions to gold medals - at domestic and international
exhibitions.
Rudolf Bakala
Rudolf Bakala General Director ATTACK, s.r.o.
General Director
All the operations during the boiler body production are provided intro-plant,i.e. we do not work in
cooperation. By this system we can control the high standard of produced boilers.
Turbulators also enable easy exchanger cleaning.The clean exchanger reaches the most effective operation parameters - high
efficiency.Technically, the new boiler line is typical with high efficiency, low flue gas temperature and the most effective combustion
Wood is favourite kind of fuel, because it gives cosy warmth and it grows practically beyond the door.
BOILER CHARACTERISTICS
The ecological warm water ATTACK DPX boilers are intended
for heating of dwelling houses and industrial objects. The
boilers are constructed for combustion of wood pieces. It is
possible to use any kind of dry wood for heating, e.g. wood logs
adequate to the boiler length.
The boiler body cooled by water is the basis of the ATTACK
DPX boilers. The welded boiler piece is made from the steel
plates of 6mm thickness.
The boiler is equipped with high efficient tubular heat
exchanger, with the special movable turbulators installed to
increase its efficiency and to clean it.
The primary air flows into the boiler hopper, the secondary air
goes into the combustion nozzle. The manufacturer makes the
basic flap settings to divide primary and secondary air.
By the ATTACK DPX LAMBDA version is this setting made
automatically by electrical servogears following evaluation of
data from the lambda probe during the boiler operation.
The combustion control system with Lambda probe ensures
optimal operation conditions for the highest boiler efficiency
and also for minimum harmful emissions in the flue gas.
The wood gasification with following combustion of the wood
gas in the combustion space ensures optimum burning of all
combustible substances. The burning process is controlled by
the suction fan. The boiler body and exchanger are isolated
with mineral wool and the boiler design is completed with the powder-covered coat.
BOILER DESCRIPTION
Boiler is constructed for combustion of wood, on principle of wood gasification by usage of the suction fan, which exhausts
flue gas from the boiler and makes underspressure in the boiler hopper. The underpressure in the
hopper ensures, that in the moment of opening of the feeding door, the clean air is sucted from the enviroment to avoid of
small elements elusion from the boiler hopper into the boiler room. Boiler room with this kind of boiler is significantly less
dusty.
Boiler consits of two chambers divided by nozzle. The boiler fuel hopper is in the bottom part equipped with the heatproof
adapting piece with longitudinal opening for transfer of the gas and
flue gas.
Quality heatproof nozzle is the essential part of the boiler. It
guarantees reliable functioning at extremely high operation
temperatures, approximately of 1100°C.The refractory adapting
pieces are resistant up to the temperatures of 1350°C. The
adapting pieces of the boiler´s ashtray part accumulate the heat
from flue gas. Thereby, their surface temperature increases and
they serve as the combustion „catalyzer“ that ensures burning out
of the harmflul emissions in the boiler and prevents their elusion
through chimney into the surrounding atmosphere.
The refractory pieces have been chosen and manufactured under very strict
view. Shape of these adapting pieces has been developed following the
long-year experiences with the purpose of reaching the best combustion
parameters of the boiler. Adapting pieces are thermally strained during the
boiler operation and thereby they are suitably divided into several parts to
enable their dilatation without the following damage.
The refractory ashtray is placed in the burning-out space under the nozzle in
the boiler rear part.The tubular exchanger with the heat-up flap above is in
the rear part of the boiler. There is also the exhaust connection for chimney. It is possible to turn this connection horizontally or
vertically, following requirements at installation.
In the upper part of the front wall, there are feeding door and in the bottom
part are ashtray door.
The boiler body is from external side thermally isolated with mineral wool, fitted
under coverings of the external coating. The controll panel for electromechanical
regulation is placed in the upper part of the boiler. The channel for primary and
secondary air inlet is in the front part of the boiler.
Boiler is equipped with the heat-up flap. This flap opens automatically, when the
feeding door is opened and shuts automatically, when the feeding door is closed.
The heat up flap ensures direct flue gas exhaust from the boiler hopper into the
chimney and eases the heating up in the boiler.
Boiler is equipped with all functional and security elements. Boiler thermostat
provides operation and keeping the adjusted temperature of the heating water.
Boiler is equipped with the safety thermostat, that turns the ventilator electrically
off in the state of emergency when the temperature exceeds 95°C.
FUEL
Prescribed fuel is dry cleft wood -
wood logs with humidity of 12-20%
and heat value of 15-17 MJ/kg.
1 2 3 4 5 6
2 - Fuse
3 - Main switch
5 - Boiler thermostat
6 - Thermomanometer
Description:
11
1 2 3 4 5 6
9 8 7 10
1 - Switch of connection 7 - Control light of operation of the Backward view of electronic regulator
central heating pump
2 - Display indicating boiler
temperature
8 - Control light of fuel insufficiency Intensity of fan operation after reaching adjusted temperature of heating water
3 - Control light of heat up
process 9 - Knob of the room thermostat Output level of Fuse
flue gas fan 2A
4 - Control light of boiler 10 - TEST button (by pressing it, at heating up
overheating appears the temperature adjusted by
the knob „6“ and at the same time, the of boiler
5 - Control light of the room
thermostat flue gas fan is switched off for
a moment)
Connection for
6 - Knob of the flue gas thermostat mixing valve
11 - Thermomanometer (12 V)
Connection for room temperature sensor
3 2 1 4 8 5 6 7
1 - Control light of the boiler operation
2 - Control light of error messages
3 - Control light of warning messages
4 - Multiline LCD dispay
5 - Button for boiler start and for change of
parameters
6 - Button for boiler stop and for change of
parameters
7 - Enter (button to confirm and to enter
the menu)
8 - Reset
9 - Thermomanometer
9
Description:
1: Lights by the boiler start with the „+“ (5) button, expires after burning out of fuel or after manual boiler stop by the „-“ (6)
button.
2: Lights in case of the following faults: - wrong value of the flue gas temperature
3: Lights or flickers following fault importance:
Reset - lights, wrong boiler temperature - lights, too high temperature - flickers, boiler overheating - do not open (tboiler
temperature over 90°C) - flickers
4: Displays operation data and enables browsing the menu. If the boiler is out of operation for longer than 15min. and does
not display any error, the display illumination is turned off automatically.
5: Turns on display illumination. After repeated pressing turns the boiler on or enables fuel feeding
6: Serves for emergency boiler stop - only in case, that there is no water in the system or if the sensor for overheating does
not work.
7: Serves for entering the menu and confirmation of the required value.
8: Button of the boiler´s safety protection against overheating. If the temperature of the boiler´s water exceeds 95°C, the
boiler stops. The boiler can be started by unmounting the cover and pressing the button, after temperature decrease to 85°C.
PYROLYSIS OF WOOD
Wood gasification is traditional technology, that improves efficiency of wood combustion. Combustion means rapid oxidation of
material, when warmth is released.
Operation of the pyrolysing boiler can be divided into three processes - warming and drying of wooden material in the hopper,
emission of water steams and gas elements and combustion of solid content (charcoal).
Each of this phases requires different conditions. However, by usual devices, there is the only possibility of regulation - closing of
the air inlet. Thereby, there is lack of air for one process and too much air for another one and also the temperature is sometimes
sufficient and sometimes not. Because of unperfect combustion, many combustible contents wastely flow out through the
chimney or react with other products of combustion and make tar.
Warming
Emission of gas contents
Gas combustion
After-combustion of gas,
Reduction of CO
BOILER FUNCTION
By feeding of new fuel - at the temperature under 200°C - it comes to drying of wood .
Near to the nozzle, at temperature of 200-700°C and limited air inlet, the wood is scanned, the wood gas is emitted and the solid
elements are produced. Emitted gas flows into the combustion chamber, burns and emits heat under the sufficient air inlet.
It reacts with air and emits combustible CO, that is immediately burned.
Incombustible waste goes through the nozzle to the ashtray.
Advantage of this approach is, that every combustion phase has ideal
conditions - in the regulated amount of primary and secondary air, as well
as in optimum differentiation of temperatures for individual phases of
combustion.
Wood gas:
- 20% of hydrogene - 0-10% of methane
- 20% of combustible CO - 50-60% of non-combustible nitrogen
Chimney installation
Chimney can be horizontally or vertically oriented by turning the
flange for 180°.
1950 mm
DP
as
K
AC
K
AC
T
AT
T
AT
150
0m m
m 2000 m
DESCRIPTION OF THE ATTACK Dpx BOILER
Regumat ATTACK-OVENTROP
Calibre DN25 DN32
Max. pressure 10 bar 10bar
Max. temperature 120°C 120°C
Value of kvs 3,9 5,3
Constructive height of isolation 365 mm 472 mm
Width of isolation 250 mm 250 mm
Axial distance 125 mm 125 mm
®
ACCESSORIES TO THE ATTACK DPX BOILERS
®
ACCUMULATION TANKS ATTACK
The accumulation tanks ATTACK are intended for accumulation and following distribution of
the heat energy from the solid fuel boiler.
ATTACK AK
Description of device
Tank for accumulation and following distribution of heat energy from solid fuel boiler, heat
pumps, electroboilers, etc.
Type
Type line of tanks with volume of 500, 800, 1000 litres, also with possibility to install electrical
heating device .
Thermal isolation
The accumulation tanks are delivered with detachable isolation of 100mm width, soft
polyurethane with leatherette covering.
Specification
Max. operation pressure of the accumulation tank: 6 bar
Max. operation temperature of the accumulation tank: 95 °C
Technical data
Description:
Accumulation tank „ATTACK AK“ is permanently connected to the closed heating system. Internal walls are not enameled. Tanks
can be accessorized with electrical heating devices with thread of G 6/4“ up to the output of 12 kW (suitable output of device is
adequate to its length and diameter of tank). Fitting of individual outlets of tank is made according to the connected circuits.
ATTACK AS
Description of device
Tank for accumulation of heating water with single heating coil (e.g. solar system), accessorized with welded flange to fit the tubular
exchanger of appropriate size, following concrete application and required output.
Type
Type line of tanks with volume of 500, 800, 1000 litres, also with possibility to install electrical heating device.
Thermal isolation
The accumulation tanks are delivered with detachable isolation of 100mm width, soft polyurethane with leatherette covering.
Specification
Max. operation pressure in the accumulation tank: 6 bar, max. operation temperature in the tank: 95 °C
Technical data
Description:
Accumulation tank is permanently connected to the closed heating system. The accumulation tanks "ATTACK AS" are
3
delivered with welded flanges for exchangers with threads of G1“ or G /4“. If the welded part on the exchanger is not used, the
6
blinding flange has to be used. Tanks can be accessorized with electrical heating devices with thread of G /4“ up to the output of
12 kW (suitable output of device is adequate to its length and diameter of tank).
®
ACCESSORIES TO THE ATTACK DPX BOILERS
®
EQUITHERMICAL CONTROLLER ATTACK SMILE
Equithermical controller ATTACK SMILE is the top
regulation element for all modifications of wood
gasifying boilers ATTACK DPX and DP. Controller
ATTACK is intended for regulation of heating
systems, including regulation of heating water. It is
used for regulation of low-temperature and warm-
water systems. it is possible to connect the
regulator with two types of room units ( with and
without display).
The equithermical regulator ATTACK SMILE includes easy installation and wide possibilities of usage.With the ATTACK SMILE it is
possible to control these aspects of the heating system :
- primary boiler circuit of the wood gasifying boiler
- recharging and discharging of accumulation storage devices
- solar system for heating of D.H.W. or additional warming of C.H.
- several heating circuits of different temperature levels
- alternative source of heat
- warming of D.H.W.
- free programmable inputs
SIMPLE INSTALLATION
Simple and quick installation is enabled via connection terminal or connection module with spring terminal for installation to the
wall.
Multifunctional display with illumination
CONTROL PANEL and simply displayed data
Multifunctional buton -
simple setting by turning and pressing
*Manual control
Buttons for quick enter
CLOCK FUNCTION
Heating with own time program, D.H.W. warming with
week time program, 15 holiday periods.
TECHNICAL DATA
( so zabudovaným
čerpadlom )