Escolar Documentos
Profissional Documentos
Cultura Documentos
Page 1 of 5
7/2/2005
Page 2 of 5
isobars. The Coriolis force and frictional drag force then balance the pressure gradient, plus or minus
centrifugal force if path happens to curve.
Velocity Profile
The roughness of the earth's surface, which causes drag on wind, converts some of wind's energy into
mechanical turbulence. Since turbulence generates at the surface, surface wind speed is much less than
wind speed at higher levels. Turbulence includes vertical as well as horizontal air movement and hence
the effect of surface frictional drag is propagated upwards. Mechanical turbulence and effect of
frictional drag gradually decrease with height and at gradient level (around 1000 to 2000 feet) the
frictional effect is negligible. Pressure gradient at this level balance by the Coriolis force (and possibly
centrifugal force), and the wind blows almost parallel to the isobars. For strong winds, the shape of the
vertical profile of wind speed depends mainly on degree of roughness of surface, which means over-all
drag effect of buildings, trees and any other projections that impede flow of wind at the surface. Three
typical velocity profiles are shown in Fig. 1, where the effect of variable surface roughness on mean
wind speeds is shown for an arbitrarily selected gradient wind of 100mph. Velocity profiles have been
determined by fitting curves to observed mind speeds at several levels. It is convenient and sufficiently
accurate to describe these profiles by a power law of the form: vh = vr*(h/hr)k, where vh is mean wind
speed at height h above ground, vr is the mean speed at reference height hr, above ground; k is the
exponent for best-fitting curve. A reference height of 10 meters or about 30ft is internationally
recommended as the standard and anemometers are usually mounted as close to this height as is
practical. Exponents for mean wind speeds vary from about 1/7 for flat open country to about for
centers of large cities.
Figure 1 - Mean velocity profiles over terrain with 3 different roughness characteristics for gradient
wind of 100mph. Courtesy Meteorological Division, Dept of Transport
Turbulence in Surface Winds
Velocity profile (Figure 1) describes only
one aspect of wind at lower levels.
Superimposed on mean speed are gusts
and lulls, which are deviations above and
below the mean. These gusts have a
random distribution over a wide range of
frequencies and amplitudes, in both time
and space. Figure 2 shows clearly the
unsteady nature of wind speed measured
by an anemometer. Gusts are frequently
the result of the introduction of fast
moving parcels of air from higher levels
into slower moving strata of air. This
mixing or turbulence is produced by
surface roughness and thermal instability. In such cases dynamic instability of flow may result when
eddies separate first from one side and then form. Turbulence caused by surface roughness is similar to
the turbulent boundary layer flow at the walls of pipes. Flow near surface encounters small obstacles
that change wind speed and introduce random vertical and horizontal velocity components at right
angles to main direction of flow. Turbulence generated by obstacles may persist downwind from
projections as much as 100 times their height. Large scale topographical features are not included in the
above-mentioned surface roughness. They can influence the flow, so they are given special
consideration in design. For instance, wind is usually much stronger over the brow of a hill or ridge
because flow lines converge over the obstructing feature and to pass the same quantity of air a higher
speed is required. Large valleys often have a strong funnelling effect that increases wind speed along the
axis of the valley. Thermal stability of air has a considerable effect on the intensity of turbulence. Cold
surface air tends to damp out mechanical turbulence; heated surface air tends to rise and to increase
7/2/2005
Page 3 of 5
turbulence. When wind is strong, air near the surface becomes thoroughly mixed and thermal stability
becomes neutral. Under these conditions, temperature differences neither damp out nor increase
mechanical turbulence caused by surface roughness. Figure 2 - Typical pressure tube anemometer
record.
Dynamic effects
Every structure has a natural frequencyof
vibration, and should dynamic loading occur
at or near it, structural damage out of all
proportion to size of load may result. For
example, bridges capable of carrying far
greater loads than the weight of a company
of soldiers have been known to break down
under dynamic loading of men marching
over them in step. Similarly, certain periodic
gusts within the wide spectrum of gustiness
in wind may find resonance with natural
vibration frequency of a building, and
although the total force caused by that
particular gust frequency would be much less
than the static design load for the building,
dangerous oscillations may be set up. This
applies not only to the structure as a whole, but also to components such as curtain wall panels and
sheets of glass. A second dynamic effect is caused by instability of flow around certain structures. Long
narrow structures such as smoke stacks, light standards and suspension bridges are particularly
susceptible to this sort of loading the other side of the object, causing an alternating pattern of eddies to
form in its wake. A side thrust is thus exerted on the object similar to the lift on an aerofoil, and since
this thrust alternates in direction, a vibration may result. Side-to-side wobbling effect of a straight stick
pulled through water is an example of this phenomenon. As research gradually provides a better
understanding of the structure of wind and the complex interactions between wind and buildings, one
can look forward to greater economy in the use of building materials through greater precision in
estimating static load; and to greater safety because of the inclusion of dynamic load in design.
Minimum Wind Design Loads for Building & Other Structures
ASCE Standard A7-98, Minimum Design Loads for Buildings and Other Structures (A7 Standard)
provides a basis for determining wind loads and other loads on structures in the United States. All
model-building codes include this standard as a reference and the new International Building Code has
adopted the A7 Standard as the recommended design method. Evaluation of wind loads can be a very
complicated process and the A7 Standard has provided the best information currently available for
dealing with these problems for rigid structures and a limited class of flexible structures. Unfortunately,
complication of wind loading also can lead to a relatively complicated procedure for code-based
evaluation of wind loads. A full evaluation of the structure, parts and portion loadings for even a
relatively simple structure can lead to lengthy and tedious calculations using the A7 Standard. The Wind
Loads on Structures program recently released by the Standards Design Group removes much of the
tedious computation for manual analysis and reduces evaluation of A7-98 to relatively simple steps. All
buildings and other structures must be design to resist environmental loads. This is a wind load. Design
wind loads can determined using 3 procedures: Simplified procedure, Analytical procedure and Wind
tunnel procedure. There are definitions one must know in order to understand procedures of determining
wind loads. These definitions are based on a dynamic point of view:
Flexible building or structure: A building or other structure is considered flexible if it contains a
significant dynamic response. Resonant response depends on the gust structure contained in the
approaching wind, on wind loading pressures generated by the wind flow about the building, and on
dynamic properties of the building or structure. Gust energy in wind is smaller at frequencies about 1
7/2/2005
Page 4 of 5
Hz; therefore resonant response of most buildings and structures with lowest natural frequency above 1
Hz will be sufficiently small that resonant response can often be ignored. When buildings or other
structures have a height exceeding 4 times the least horizontal dimension or when there is reason to
believe that the natural frequency is less than 1 Hz (natural period greater than 1sec.), the natural
frequency should be investigated.
Rigid building or structure: Building or other structure whose fundamental frequency is greater or equal
than 1 Hz. A general guidance is that the most rigid buildings and structures have height to minimum
width less than 4.
Design Force, F: Equivalent static force is used in determination of wind loads for open buildings and
other structures.
Design pressure, P: Equivalent static pressure to be used in the determination of wind loads for
buildings.
Main wind-force resisting system: An assemblage of structural elements that provide stability and
support for overall structure.
Wind Load Design Analytical Procedure
Gust effect factor G
For rigid structures, gust effect factor shall be taken as 0.85 or calculated by: G = 0.925*[(1+1.7gQIzQ)/
(1+1.7gvIz)]. Iz = c(33/ )1/6, where Iz is the intensity of turbulence at height (equivalent height of
structure defined as 0.6h); gQ and gv shall be taken as 3.4. Refer to ASCE 7-98 for values. Background
response Q = SQRT(1/[1+0.63*((B+h)/Lz)0.63]), where Lz = l( /33)^
Flexible or Dynamically Sensitive Structures
For dynamically sensitive structures, gust factor shall be calculated by: Gf = 0.925*[(1+1.7*Iz*SQRT
(gQ2Q2+gR2R2))/(1+1.7gvIz)]
gQ and gv shall be taken as is given by: gR = SQRT(2*ln(3600n1))+[0.577/SQRT(2*ln(3600n1))],
where n1 = Building natural frequency (Hz). The resonant response factor = R = SQRT(RnRhRb
(0.53+0.47Rl)/B), where Rn = 7.47*N1/(1+10.3N1)5/3. Reduced the frequency, N1 = n1Lz/
. Rl = 1/n
( /33)^
*V(88/60),
7/2/2005
Page 5 of 5
of enclosed buildings. qi = qz for positive internal pressure evaluation in partially enclosed buildings. G
= Gust effect factor. Cp = External pressure coefficient. (GCpi) = Internal pressure coefficient.
Low Rise Buildings
Design wind pressures for main wind force resisting system of low-rise buildings shall be determined
using equation: p = qh[(GCpf) - (GCpi)] (psf), where (GCpf) = External pressure coefficient.
Flexible Buildings
Design wind pressures for main wind force resisting system of flexible buildings shall be determined
from following equation: p = qGfCp - qi(GCpi) (psf)
Wind Loads Commentary
Maximum Along-Wind Displacement
Maximum along-wind displacement as a function of height above ground surface is: Xmax(z) =
p*B*h*Cfx 2/[2m1(2*PI*n1)2]*KG, where fundamental model shape =
= (z/h)^ . =
Mode exponent. p = Air density. Cfx = Mean along-wind force coefficient. Modal mass =
, where (z) = Mass per unit height. K = 1.65^/(+ +1).
V(z/33)^, where V is 3-sec. gust speed in Exposure C at reference height; and are terrain
exposure constants given in tables.
RMS Along-Wind Acceleration
RMS Along-wind acceleration as a function of height above ground surface is:
.
Maximum Along-Wind Acceleration
Maximum along-wind acceleration as a function of height above ground surface is:
gx = SQRT(2*ln(n1T)) + 0.5772/SQRT(2*ln(n1T)), where T = time length over which minimum
acceleration is computed, usually taken to be 3600sec. to represent 1hr.
7/2/2005