Air-Cooled Reciprocating Chiller
AGR
055-100
Vintage A

To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Index
Page(s)
Heading
Description

2, 3
Index

4
Revision History
Parts List Revisions

5, 6
Nomenclature
Unit Serial Number and Unit Model Number Definitions
7- 12
Compressors

7
Unit Compressors
208V

8
Unit Compressors
230V

9
Unit Compressors
460V

10
Unit Compressors
575V

11
Diagram
Compressor Common Parts

12
Components
Unloader Valves, Oil Pressure Control, High Pressure Control, Shrader
13- 29
Power Panel

13
Diagrams
Panel Layout, Latches, Catches and Hinges

14
Components- All Sizes
Latches, Catches, Hinges, Ground Screw, Unit % Amp Draw,

Ground Fault

15
Components- 055- 070
Speedtrol Transformer, Phase Voltage Monitor, Fan Contactors and

Fuses, Control Transformer and Fuses, Part Winding TD

16
Components- 075- 100
Speedtrol Transformer, Phase Voltage Monitor, Fan Contactors and

Fuses, Control Transformer and Fuses, Part Winding TD

17
Components- AGR055
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub

18
Components- AGR060
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub

19
Components- AGR065
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub
20, 21
Components- AGR070
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub
22, 23
Components- AGR075
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub
24, 25
Components- AGR080
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub

26
Components- AGR085
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub

27
Components- AGR090
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub

28
Components- AGR095
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub

29
Components- AGR100
Contactors, Circuit Breakers, Power Block, Disconnect, Power Hub
30- 36
Control Panel- UNT Controls (C11= J**)

30
Diagram
UNT Control Panel- Left Side

31
Components
UNT Control Panel- Left Side

32
Diagram
UNT Control Panel- Right Side

33
Components
UNT Control Panel- Right Side

34
Zone Terminal Display
All Sizes- Diagram and Components

35
Diagrams
Unit Sensors, L.L. Soldenoid Valve Junction Box, Pressure Controls

36
Components
Unit Sensors, L.L. Soldenoid Valve Junction Box, Pressure Controls
37- 43
Control Panel- MicroTech Controls (C11= M**)

37
Diagram
MicroTech Control Panel- Left Side

38
Components
MicroTech Control Panel- Left Side

39
Diagram
MicroTech Control Panel- Right Side

40
Components
MicroTech Control Panel- Right Side

41
Keypad Display
All Sizes- Diagram and Components

42
Diagrams
Unit Sensors, L.L. Soldenoid Valve Junction Box, Pressure Controls

43
Components
Unit Sensors, L.L. Soldenoid Valve Junction Box, Pressure Controls

44
Speedtrol Components, Convenience Outlet Components, Gauges

44
Components & Diagram
All Sizes
45- 51
Condenser Components

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 2

Index

Continued


45
Diagrams

46
Diagrams

47
Components

48
Components

49
Components

50
Components

51
Components
52- 58
Cabinet

52
Diagram

53
Components

54
Diagram
55- 58
Components
59- 64
Piping Components

59
Diagrams

60
Components

61
Components

62
Components

63
Components

64
Components

65 Evaporator

65
Diagrams & Components

66
Vibration Isolators

66
Flow Switch

66
Alarm Bell Kit
CPL1 CPL3 Critical Parts List

AGR055A- 060A
AGR065A- 100A
Condenser Fan Deck
Condenser Fan Motors
Sheet Metal & Hardware: AGR055A- 070A
Sheet Metal & Hardware: AGR075A- 100A
Condenser Coils
Panels, Control/Power Doors, Hardware
Panels, Control/Power Doors, Hardware
Coil Guards, Base Frame Guards, Hardware
Coil Guards, Base Frame Guards, Hardware
Suction, Discharge and Liquid Lines
AGR055, 060A
AGR065, 070A
AGR075A
AGR080A
AGR085, 090, 095, 100A
All Sizes
All Sizes
Field Installed Accessory
Field Installed Accessory
Critical Parts List

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 3

Parts List Revision History



Revision
Date Description
NEW
12/97
New

A
9/98
Change made to Page 48: Corrected part numbers for size 070A and

075-100A Totally-Enclosed 2.0 hp Motors.

B
5/01
Page 33 - Added Relay/Base Socket part #074805901.

Page 34 - Removed Zone Terminal Display Only part #074805501.

Page 36 - Part #047609001 was corrected to read #074609001.

C
10/01
Pages 36 & 43-Bub. #830 pn was changed from 735026315 to
735048015.

D
12/01
Page 15 - Bub 661A (460V, AGR055/065 & AGR070) pn 042763120

was changed to 042753120.

E
10/02
Page 47 - Bub. #708; Fan Prop 28", 1.5 HP part number 072941301 was
incorrect, the correct number is 072941302.

F
10/2004
Pages 7 thru 10 - Removed Copeland Compressor information.

G
4/2005
Page 65 - Added note (**) to 'Components' table about replacing the

evaporator.

H
10/2005
Page 44 - Bub #2 strap Capacitor pn 028765100 was changed to
330577701.

Page 51 - Description of bub #6 on all tables changed from LH to RH.

Description of bub #7 on all tables changed from RH to LH.

J
05/06
Pages 45 & 46 - Control box diagram heading has word 'opposite' added.
Added notes/info on discharge header connection, bubbles #6 & 7

were switched and bubbles #8 & 9 were switched.

Page 51 - Added- Note: The coil hand (left or right) is based on the
discharge header connection point.

K
8/06
Page 9 - Compressor 2, 6 Step (08 = 5) was changed to (08 = 6).

L
12/08
Page 65 - Add Heater p/n 735079719 to model #s E1204D1, E1204D2,

E1255D1 and E1455D1.

M
5/09
Page 48 - Ref 701 change Motors-AGR 045-065A p/n from 072941302 to

046744200.

N
10/09
Updated the Cover and Revision pages with current logo design.

Page 36- Changed the qty. of Ref # 751 p/n 073074003 from 1pc. to 2pc.

Page 37- Changed the fourth MHPR from the left (Ref Bub 260) from

MHPR1 to MHPR2.

P
06/11
Page 38 - Correct MT Controller part number to 065487306 (was

065487311).

Q
08/2014
Page 44: Corrected heading in lower chart, was "Gauges (Code23=B)".

Corrected descr. for Suct and Disch Gauges, they were reversed.

Page 48: Corrected heading for Motors, was AGR 045, 065A.

R
07/2015
Pages 7,8,9,10: Corrected heading for Compr 1, 6-Step, was 08=4.

Pages CPL1 - CPL3: Added CPL pages.

Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 4

Nomenclature
Serial Number
5 7A 12345 01
Engineering Revision
Serial Number
Factory
5= Staunton,VA

Year and Month of Manufacture:


Year
Month
6= 1996
A= Jan.
7= 1997
B= Feb.
8= 1998
C= Mar.
9= 1999
D= Apr.

E= May

F= Jun

G= Jul

H= Aug

J= Sep.

K= Oct.

L= Nov.

M= Dec.

Unit Model Number


AGR 100 A S
Application
S= Standard Cooling
E= High Efficiency
Vintage
Nominal Tonnage
ex. 100 = 100 Tons
Unit Type:
AGR= Air- Cooled Global
Reciprocating Compressor Chiller

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 5

Nomenclature
Continued

Unit Model Number- Complete


AGR***A
Code

S 27 AL P

03

04

05

06

C 04 2 A JYY D C R F S 11 1 B B E

07

08

09 10

11

12 13

03 Application

S= Standard Cooling
04 Voltage

12= 208/60/3

27= 460/60/3

29= 230/60/3

37= 575/60/3
05 Starting Option

AL= Across-The-Line

PW= Part Winding
06 Power Connection

P= Single Point Power Block

D= Non-Fused Disconnect (Unit Mounted)
07 Compressor Short Circuit Protection

Y= None

C= Circuit Breakers
08 Capacity Control

04= 4 Steps Capacity Control

06= 6 Steps Capacity Control

14 17 18

19

20 22 23 24

1 EYA

25

26

17 Protective Guard

Y= Not Required

A= Base Frame Guard around Entire Unit

F= Vertical Condenser Coil Fin Guard

and Option "A"

G= Vertical Condenser Coil Fin Guard

Only
18 Head Pressure Control

F= FanTrol w/ Low Ambient T-Stat

S= SpeedTrol w/ Low Ambient Start
19 Condenser Coil Fin Material

11= Aluminum

21= Copper

31= Aluminum w/ Baked Phenolic Coat

41= Copper w/ Baked Phenolic Coat
20 Condenser Fan Motors

1= Open Drip-Proof

2= Totally Enclosed

(SpeedTrol Motors are ALWAYS ODP)

09 Hot Gas Bypass



Y= None

2= HGBP Circuits 1 & 2

22 High Return Water/High Ambient Unload



Y= Not Required

R= High Water Return Unloader

A= High Ambient Unloader

B= Both R & A

10 Control Circuit Transformer



Y= None

A= Control Circuit Transformer

23 Gauges

Y= None

A= Suction, Discharge, Oil Gauge- Ckts 1 & 2

11 Control Thermostat Options



J** = UNT Johnson Controls

J*D = UNT w/ Zone Terminal Display

M** = MicroTech Controls

24 & 25 Approval Listing and Packaging Options

12 Phase Failure, Reversal



D= Phase Failure, Reversal with

Under/Over Voltage and LED Lights

V= Phase Failure, Reversal with

Under/Over Voltage

Y= Not Required
13 Miscellaneous Options

Y= Not Required

C= 115V Convenience Outlet

G= Ground Fault
14 Replaceable Core Filter Drier

Y= None

R= Replaceable Core Filter Driers

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

26 Sensor Options

UNT (example: EYA)

E**= English Units

M**= Metric Units

*Y*= Modem (Not Available)

**A= Outside Air Temp

**E= Entering Water Temp.

**U= Limited UNT Sensor Package

MicroTech (example: EMR)

E**= English Units

M**= Metric Units

*Y*= No Modem

*M*= Modem

**R= Standard Package

**B= Refrigerant Temp. Package

**D= % of Unit Amp. Draw Package

**C= "R" + "B" + "D"

Rev. R 07/15

RPL 571180 / Page 6

Compressors

Compressor Arrangements
Top View

Control Box

1
Evap

Compressor Part Numbers


208/60/3 (04= 12), Across-the-Line (C05= AL) or Part Winding (C05= PW)
Unit Model No. Compressor 1
4 Step (08=4)

Compressor 1
6 Step (08=6)

Compressor 2
4 Step (08=4)

Compressor 2
6 Step (08=6)

055............... 071846201................... 071838301...................... 071846201..................071838301




060............... 071846201................... 071838301...................... 071846701..................071846801

065............... 071846701................... 071846801...................... 071846701..................071846801

070............... 071846701................... 071846801...................... 071835901..................071838001


075............... 071835901................... 071838001...................... 071835901..................071838001
080............... 071835901................... 071838001...................... 074554901..................074554901
085............... 074554901................... 074554901...................... 074554901..................074554901
090............... 074554901................... 074554901...................... 074554901..................074554901
095............... 074554901................... 074554901...................... 074556901..................074556901
100............... 074556901................... 074556901...................... 074556901..................074556901

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 7

Compressors
Continued

Compressor Part Numbers


230/60/3 (04= 29), Across-the-Line (C05= AL) or Part Winding (C05= PW)
Unit Model No. Compressor 1

4 Step (08=4)

Compressor 1
6 Step (08=6)

Compressor 2
4 Step (08=4)

Compressor 2
6 Step (08=6)

055..................071846201....................... 071838301.......................... 071846201......................071838301




060..................071846201....................... 071838301.......................... 071835401......................071836801

065..................071835401....................... 071836801.......................... 071835401......................071836801

070..................071835401....................... 071836801.......................... 071835701......................071837601


075..................071835701....................... 071837601.......................... 071835701......................071837601
080..................071835701....................... 071837601.......................... 074554901......................074554901
085..................074554901....................... 074554901.......................... 074554901......................074554901
090..................074554901....................... 074554901.......................... 074554901......................074554901
095..................074554901....................... 074554901.......................... 074556901......................074556901
100..................074556901....................... 074556901.......................... 074556901......................074556901

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 8

Compressors
Continued

Compressor Part Numbers


460/60/3 (04= 27), Across-the-Line (C05= AL) or Part Winding (C05= PW)
Unit Model No. Compressor 1

4 Step (08=4)

Compressor 1
6 Step (08=6)

Compressor 2
4 Step (08=4)

Compressor 2
6 Step (08=6)

055..................071846101....................... 071838401.......................... 071846101......................071838401




060..................071846101....................... 071838401.......................... 071835501......................071836901

065..................071835501....................... 071836901.......................... 071835501......................071836901

070..................071835501....................... 071836901.......................... 071835801......................071837701


075..................071835801....................... 071837701.......................... 071835801......................071837701
080..................071835801....................... 071837701.......................... 074555101......................074555101
085..................074555101....................... 074555101.......................... 074555101......................074555101
090..................074555101....................... 074555101.......................... 074555101......................074555101
095..................074555101....................... 074555101.......................... 074557101......................074557101
100..................074557101....................... 074557101.......................... 074557101......................074557101

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 9

Compressors
Continued

Compressor Part Numbers


575/60/3 (04= 37), Across-the-Line (C05= AL) or Part Winding (C05= PW)
Unit Model No. Compressor 1

4 Step (08=4)

Compressor 1
6 Step (08=6)

Compressor 2
4 Step (08=4)

Compressor 2
6 Step (08=6)

055..................071846601....................... 071838501.......................... 071846601......................071838501




060..................071846601....................... 071838501.......................... 071835601......................071837001

065..................071835601....................... 071837001.......................... 071835601......................071837001

070..................071835601....................... 071837001.......................... 071837801......................071837801


075..................071837801....................... 071837801.......................... 071837801......................071837801
080..................071837801....................... 071837801.......................... 074555501......................074555501
085..................074555501....................... 074555501.......................... 074555501......................074555501
090..................074555501....................... 074555501.......................... 074555501......................074555501
095..................074555501....................... 074555501.......................... 074557501......................074557501
100..................074557501....................... 074557501.......................... 074557501......................074557501

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 10

Compressors
Continued

Compressor Common Parts


Diagrams
3

4
19

18

4
5

14 16
17 20
27 12

21 26

28
15

25
10 11

13

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 11

Compressors
Continued

Compressor Common Parts


Components
Part
Ref.
Qty.*
Description
Number
No.

3
Unloader Valve
046497300
2

4
Gasket- Unloader Valve
072927901 2

5
Conduit
017817820 1

9
ValveNo
Core
047135501
1

10
T- .25FL X .25MPT
001373200
1

11
Flare
Cap
000540900 2

12
T- .25 X.25 X .25


30HP, 35HP, 40HP Compressors
070229302
5

50HP, 60HP Compressors
070229301
1
13
Elbow- .25FL X .25P
001124300
1

14
Nut.25"
000028600
2

15
Oil Control Bracket


30HP, 35HP, 40HP Compressors 074804101 1


50HP, 60HP Compressors
074804201 1
16
Oil Switch Enclosure
071240301
1

17
Oil Switch Cover
071240201 1

18
Screw
735032742
2

19
Screw
038990807
2

20
Oil
Switch
Grommet
074635001
1

21
OP1/OP2 Cable


UNT Control
074642102
1


MicroTech
074642101
1
25
Gasket
027017035
1
26
Oil Pressure Control (OP1/OP2)

UNT Control
001354900
1

MicroTech
070971801 1
27
High
Pressure
Control
(HP1/HP2)


MicroTech Units Only
073074002
1
28
Conduit for HP1/HP2


MicroTech Units Only
073238630
1
*Quantities are for ONE compressor. Each unit has two compressors.

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 12

Power Panel
Panel Diagram
991

993
992
990

356
FB5

T1

GRD

671
290

674 660A 670


661A

660
661

FB7

550

660

PB 1

553

690

FB8

CB2

CB6

ON

ON

OFF

OFF

664

TD1

CB2

CB6

ON

ON

OFF

OFF

DS 1

TD2

M11

M12

346

M13

CT

4 plcs.
(055- 070)
6 plcs.
(075- 100

552

551

661

T10
FB6

G
F
P

701

PVM

M21

M22

M23

M1

M5

M2

M6

534

536

535

999

980
986

533

989

SC

RES1

Latches, Catches, Hinges


170 171
133
170
171
170 171
132

952

8 plcs.

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 13

Power Panel

AGR 055, 060, 065, 070, 075, 080, 085, 090, 095, 100 Common Components
Latches, Catches, Hinges, Ground Screw,
Unit Amp Draw % Option, Ground Fault Relay & Sensor

Schem.
Ref.
Description
Sym.
No.


Latches, Catches, Hinges

132
Bracket- Magnet

133
Door Catch

170
Fastener- Magnet

171
Catch Bracket

952 Hinge




Ground Screw

701
GRD
Ground
Screw




Unit % Amps (C26= **D or **C)

980
CT
Transformer- MicroTech Units (C11= M**)

986
RES1
ResistorMicroTech Units (C11= M**)

989
SC
Signal
ConverterMicroTech Units (C11=M**)

999
Signal Converter Spacer


990
GFP
991
992
993

Ground Fault
Ground Fault Protection Relay
Ground Fault Relay Sensor
Ground Fault Sensor Mount
Ground Fault Relay Mount

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

Part
Number
070753601
039962900
034905200
034905000
032457700

Qty.
1
2
4
4
8

028798500 1

735076511
735003223
049264901
048166702

1
1
1
4

736017401
736017402
048837101
048844301

1
1
1
1

RPL 571180 / Page 14

Power Panel

AGR 055, 060, 065, 070 Common Components


Speedtrol Transformer, Phase Voltage Monitor,
Fan Contactors and Fuses, Control Transformer and Fuses, Part Winding TD
Schem.
Ref.
Description
Sym.
No.

290
T10
Transformer- Speedtrol (C18= S)


T10
TransformerSpeedtrol (C18= S)


346
TD1, TD2


356
PVM


PVM


PVM


356
PVM


PVM

660A


660


661A













661










664

670


671
674

208/ 460V 575V


Part
230V
Number
046738109
1
1
046738103
1

Part Winding Time Delay (C05= PW)

028210101
2 2 2

Phase Voltage Monitor (C12= D)


Phase Voltage Monitor (C12= D)
Phase Voltage Monitor (C12= D)

070269963
1
070269965
1
070269966

Phase Voltage Monitor (C12= V)


Phase Voltage Monitor (C12= V)

070269930
1
1
070269966

FB6
FB6

Fuse Block- Speedtrol Units (C18= S)


Fuse Block- Fantrol Units (C18= F)

046500002
1
1
1
070989801
1 1 1

FB7

Fuse Block

070989801
1 1 1

F6
F6
F6
F6
F6
F6
F6
F6

Fuse- Speedtrol Units (C18= S)


Fuse- Speedtrol Units (C18= S)
Fuse- Fantrol Units (C18= F): AGR055 - 065
Fuse- Fantrol Units (C18= F): AGR055 - 065
Fuse- Fantrol Units (C18= F): AGR055 - 065
Fuse- Fantrol Units (C18= F): AGR070
Fuse- Fantrol Units (C18= F): AGR070
Fuse- Fantrol Units (C18= F): AGR070

042753121
2
042753116
2
042753122
3
042753120
3
042753117
042753123
3
042753120
3
042753117

F7
F7
F7
F7
F7
F7

Fuse: AGR055 - 065


Fuse: AGR055 - 065
Fuse: AGR055 - 065
Fuse: AGR070
Fuse: AGR070
Fuse: AGR070

042753122
3
042753120
3
042753117
042753123
3
042753120
3
042753117

Fan Motor Contactor


Fuse- 5A
Fuse- 4.5A
Fuse Block (C10= A)

041769601
4
4
4
049759811
2 2
049759819 2
070971001
1 1 1

Control Transformer (C10= A)

073191103

M11,12,21,22

F5
F5
FB5
T1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 15

Power Panel

AGR 075, 080, 085, 090, 100 Common Components


Speedtrol Transformer, Phase Voltage Monitor,
Fan Contactors and Fuses, Control Transformer and Fuses, Part Winding TD
Schem.
Ref.
Description
Sym.
No.

290
T10
Transformer- Speedtrol (C18= S)


T10
TransformerSpeedtrol (C18= S)


346
TD1, TD2


356
PVM


PVM


PVM


PVM


PVM


660A
FB6

FB6

208/ 460V 575V


Part
230V
Number
046738109
1
1
046738103
1

Part Winding Time Delay (C05= PW)

028210101
2 2 2

Phase Voltage Monitor (C12= D)


Phase Voltage Monitor (C12= D)
Phase Voltage Monitor (C12= D)
Phase Voltage Monitor (C12= V)
Phase Voltage Monitor (C12= V)

070269963
1
070269965
1
070269966
070269930
1
1
070269966

Fuse Block- Speedtrol Units (C18= S)


Fuse Block- Fantrol Units (C18= F)

046500002
1
1
1
070989801
1 1 1

Fuse Block

070989801
2 2 2

F6
F6

Fuse- Speedtrol Units (C18= S)


Fuse- Speedtrol Units (C18= S)

042753121
2
042753116
2

1
1

660


661A








FB7, FB8

F6
F6

Fuse- Fantrol Units (C18= F)


Fuse- Fantrol Units (C18= F)

042753123
3
042753120

661

F7, F8
F7, F8

Fuse
Fuse

042753123
6
042753120

M11- 23

Fan Motor Contactor

041769601

F5
F5
F5

Fuse- 8A
Fuse- 3.5A
Fuse- 5A

049759814 2
049759820 2
049759811 2

FB5

Fuse Block (C10= A)

070971001
1 1 1

Control Transformer (C10= A)


Control Transformer (C10= A)

073191104
1
1
038253929


664



670





671


674

T1
T1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 16

Power Panel

AGR 055A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 250A


DS1
Disconnect Switch- 150A


DS1
Disconnect Switch- 100A

N/S
Power Hub- 2"

N/S
Power Hub- 1"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372706
1
1
1
047442104 1
047442102 1
047442101 1
038683000
1
038682700
1
1

Across- the - Line Start (C05= AL)


Ref.
No.

Schem.
Sym.

Description

533
M1
Compressor Contactor- Compressor 1

534
M5
Compressor Contactor- Compressor 1

535
M2
Compressor Contactor- Compressor 2

536
M6
Compressor Contactor- Compressor 2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit
Breaker- Compressor 1 (C07= C)

552
CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
BreakerCompressor 2 (C07= C)


CB2
Circuit
BreakerCompressor 2 (C07= C)

553
CB6
Circuit Breaker- Compressor 2 (C07= C)

027514405
1 1 1
027514405
1
N/A
N/A
027514405
1 1 1
027514405
1
N/A
N/A
047359312
1
047359332
1
047359346
1
047359312
1
N/A
N/A
047359312
1
047359332
1
047359346
1
047359312
1
N/A
N/A

Part Winding Start (C05= PW)


Ref.
No.

Schem.
Sym.

Part
Number

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)
552
CB2
Circuit Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)

553
CB6
Circuit
Breaker- Compressor 2 (C07= C)


CB6
Circuit
BreakerCompressor 2 (C07= C)


CB6
Circuit Breaker- Compressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

208/ 460V 575V


230V

027514405 1
027514403
1
027514405 1
027514403
1
027514405 1
027514403
1
027514405 1
027514403
1
047359312
1
047359332
047359346
047359312
1
047359332
1
047359346
047359312
1
047359332
1
047359346
047359312
1
047359332
1
047359346

Rev. R 07/15

1
1
1
1
1
1

RPL 571180 / Page 17

Power Panel

AGR 060A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 400A


DS1
Disconnect
Switch- 150A

N/S
Power
Hub2.5"

N/S
Power
Hub1.5"

N/S
Power
Hub1"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372706
1
1
1
072937501
1
047442102 1 1
041769300
1
038682900
1
038682700
1

Across- the - Line Start (C05= AL)


Ref.
No.

Schem.
Sym.

Description

533
M1
Compressor Contactor- Compressor 1

534
M5
Compressor Contactor- Compressor 1

535
M2
Compressor Contactor- Compressor 2

536
M6
Compressor Contactor- Compressor 2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit
Breaker- Compressor 1 (C07= C)

552
CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
BreakerCompressor 2 (C07= C)


CB2
Circuit
BreakerCompressor 2 (C07= C)

553
CB6
Circuit Breaker- Compressor 2 (C07= C)

027514405
1 1 1
027514405
1
N/A
N/A
027514406
1
1
1
027514406
1
N/A
N/A
047359312
1
047359332
1
047359346
1
047359312
1
N/A
N/A
047359313
1
047359332
1
047359346
1
047359313
1
N/A
N/A

Part Winding Start (C05= PW)


Ref.
No.

Schem.
Sym.

Part
Number

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)
552
CB2
Circuit Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)

553
CB6
Circuit
Breaker- Compressor 2 (C07= C)


CB6
Circuit
BreakerCompressor 2 (C07= C)


CB6
Circuit Breaker- Compressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

208/ 460V 575V


230V

027514405 1
027514403
1
027514405 1
027514403
1
027514406
1
027514404
1
027514406
1
027514404
1
047359312
1
047359332
047359346
047359312
1
047359332
1
047359346
047359313
1
047359344
1
047359346
047359313
1
047359344
1
047359346

Rev. R 07/15

1
1
1
1
1
1

RPL 571180 / Page 18

Power Panel

AGR 065A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 400A


DS1
Disconnect Switch- 250A


DS1
Disconnect Switch- 150A

N/S
Power Hub- 2.5"

N/S
Power Hub- 1.5"

N/S
Power Hub- 1.2"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372706
1
1
1
072937501
1
047442104 1
047442102 1
041769300
1
038682900
1
038682800
1

Across- the - Line Start (C05= AL)


Ref.
No.

Schem.
Sym.

Description

533
M1
Compressor Contactor- Compressor 1

534
M5
Compressor Contactor- Compressor 1

535
M2
Compressor Contactor- Compressor 2

536
M6
Compressor Contactor- Compressor 2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit
Breaker- Compressor 1 (C07= C)

552
CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
BreakerCompressor 2 (C07= C)


CB2
Circuit
BreakerCompressor 2 (C07= C)

553
CB6
Circuit Breaker- Compressor 2 (C07= C)

027514406
1
1
027514406
1
N/A
027514406
1
1
027514406
1
N/A
047359313
1
047359332
1
047359346
047359313
1
N/A
047359313
1
047359332
1
047359346
047359313
1
N/A

1
N/A
1
N/A

1
N/A

1
N/A

Part Winding Start (C05= PW)


Ref.
No.

Schem.
Sym.

Part
Number

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)
552
CB2
Circuit Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)

553
CB6
Circuit
Breaker- Compressor 2 (C07= C)


CB6
Circuit
BreakerCompressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

208/ 460V 575V


230V

027514406
1
027514404
1
027514406
1
027514404
1
027514406
1
027514404
1
027514406
1
027514404
1
047359313
1
047359344
047359346
047359313
1
047359344
1
047359346
047359313
1
047359344
1
047359346
047359313
1
047359344
1

Rev. R 07/15

1
1
1
1
1
1

RPL 571180 / Page 19

Power Panel

AGR 070A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 400A


DS1
Disconnect
Switch- 250A


DS1
Disconnect
Switch- 150A

N/S
Power
Hub2.5"

N/S
Power
Hub1.5"

N/S
Power Hub- 1.2"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372706
1
1
1
072937501
1
047442104 1
047442102 1
041769300
1
038682900
1
038682800
1

Across- the - Line Start (C05= AL)


Ref.
No.

Schem.
Sym.

Description

533
M1
Compressor Contactor- Compressor 1

534
M5
Compressor Contactor- Compressor 1

535
M2
Compressor Contactor- Compressor 2


M2
Compressor
Contactor- Compressor 2

536
M6
Compressor
Contactor- Compressor 2

550
CB1
Circuit
BreakerCompressor 1 (C07= C)


CB1
Circuit
BreakerCompressor
1 (C07= C)


CB1
Circuit
BreakerCompressor
1 (C07= C)

551
CB5
Circuit
BreakerCompressor
1 (C07= C)

552
CB2
Circuit
BreakerCompressor
2 (C07= C)


CB2
Circuit
BreakerCompressor
2
(C07= C)


CB2
Circuit
BreakerCompressor
2
(C07= C)

553
CB6
Circuit Breaker- Compressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

027514406
1
1
027514406
1
N/A
027514407 1
027514406
1
027514407
1
N/A
047359313
1
047359332
1
047359344
047359313
1
N/A
047359314
1
047359333
1
047359346
047359314
1
N/A

Rev. R 07/15

1
N/A
1
N/A

1
N/A

1
N/A

RPL 571180 / Page 20

Power Panel

AGR 070A Components, Continued

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Part Winding Start (C05= PW)


Ref.
No.

Schem.
Sym.

Part
Number

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)
552
CB2
Circuit Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)

553
CB6
Circuit
Breaker- Compressor 2 (C07= C)


CB6
Circuit
BreakerCompressor 2 (C07= C)


CB6
Circuit Breaker- Compressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

208/ 460V 575V


230V

027514406
1
027514404
1
027514406
1
027514404
1
027514407 1
027514404
1
027514407 1
027514404
1
047359313
1
047359344
047359346
047359313
1
047359344
1
047359346
047359314
1
047359345
1
047359348
047359314
1
047359345
1
047359348

Rev. R 07/15

1
1
1
1
1
1

RPL 571180 / Page 21

Power Panel

AGR 075A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 400A


DS1
Disconnect
Switch- 250A


DS1
Disconnect
Switch- 150A

N/S
Power
Hub3"

N/S
Power
Hub1.5"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372706
1
1
1
072937501
1
047442104 1
047442102 1
041769100
1
038682900
1
1

Across- the - Line Start (C05= AL)


Ref.
No.

Schem.
Sym.

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1

535
M2
Compressor
Contactor- Compressor 2


M2
Compressor
ContactorCompressor 2

536
M6
Compressor
ContactorCompressor 2

550
CB1
Circuit
BreakerCompressor
1 (C07= C)


CB1
Circuit
BreakerCompressor
1
(C07= C)


CB1
Circuit
BreakerCompressor
1
(C07= C)

551
CB5
Circuit
BreakerCompressor
1
(C07= C)

552
CB2
Circuit
BreakerCompressor
2
(C07= C)


CB2
Circuit
BreakerCompressor
2
(C07=
C)


CB2
Circuit Breaker- Compressor 2 (C07= C)
553
CB6
Circuit Breaker- Compressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

027514407 1
027514406
1
027514407
1
N/A
027514407 1
027514406
1
027514407
1
N/A
047359314
1
047359333
1
047359346
047359314
1
N/A
047359314
1
047359333
1
047359346
047359314
1
N/A

Rev. R 07/15

1
N/A
1
N/A

1
N/A

1
N/A

RPL 571180 / Page 22

Power Panel

AGR 075A Components, Continued

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Part Winding Start (C05= PW)


Ref.
No.

Schem.
Sym.

Part
Number

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)
552
CB2
Circuit Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)

553
CB6
Circuit
Breaker- Compressor 2 (C07= C)


CB6
Circuit
BreakerCompressor 2 (C07= C)


CB6
Circuit Breaker- Compressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

208/ 460V 575V


230V

027514407 1
027514404
1
027514407 1
027514404
1
027514407 1
027514404
1
027514407 1
027514404
1
047359314
1
047359345
047359348
047359314
1
047359345
1
047359348
047359314
1
047359345
1
047359348
047359314
1
047359345
1
047359348

Rev. R 07/15

1
1
1
1
1
1

RPL 571180 / Page 23

Power Panel

AGR 080A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 840MA


PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 400A


DS1
Disconnect
Switch- 250A

N/S
Power
Hub 2"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372724
1
030372706
1
1
072937501
1
047442104 1 1
038683000
1
1
1

Across- the - Line Start (C05= AL)


Ref.
No.

Schem.
Sym.

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1

535
M2
Compressor
Contactor- Compressor 2


M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor 2

536
M6
Compressor
ContactorCompressor 2


M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2

550
CB1
Circuit
BreakerCompressor
1
(C07=
C)


CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit Breaker- Compressor 1 (C07= C)

551
CB5
Circuit Breaker- Compressor 1 (C07= C)

552
CB2
Circuit Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)

553
CB6
Circuit
Breaker- Compressor 2 (C07= C)


CB6
Circuit Breaker- Compressor 2 (C07= C)

CB6
Circuit Breaker- Compressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

027514407 1
027514406
1
1
027514407
1
N/A
N/A
072288701 1
027514407
1
027514406
1
072288701 1
027514407
1
027514406
1
047359314
1
047359333
1
047359346
1
047359314
1
N/A
N/A
047359315
1
047359330
1
047359346
1
047359315
1
047359330
1
047359346
1

Rev. R 07/15

RPL 571180 / Page 24

Power Panel

AGR 080A Components, Continued

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Part Winding Start (C05= PW)


Ref.
No.

Schem.
Sym.

Description


533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2


M6
Compressor Contactor- Compressor 2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit Breaker- Compressor 1 (C07= C)

CB1
Circuit Breaker- Compressor 1 (C07= C)
551
CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)

CB5
Circuit Breaker- Compressor 1 (C07= C)
552
CB2
Circuit Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)


CB2
Circuit
Breaker- Compressor 2 (C07= C)

553
CB6
Circuit
Breaker- Compressor 2 (C07= C)


CB6
Circuit
BreakerCompressor 2 (C07= C)


CB6
Circuit Breaker- Compressor 2 (C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Part
Number

208/ 460V 575V


230V

027514407 1
027514404
1
027514407 1
027514404
1
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
047359314
1
047359345
047359348
047359314
1
047359345
1
047359348
047359315
1
047359330
1
047359346
047359315
1
047359330
1
047359346

Rev. R 07/15

1
1

1
1
1

RPL 571180 / Page 25

Power Panel

AGR 085A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 840MA


PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 600A


DS1
Disconnect
Switch- 250A

N/S
Power
Hub2"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372724
1
030372706
1
1
072937503
1
047442104 1 1
038683000
1
1
1

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description


533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2


M6
Compressor Contactor- Compressor 2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit
Breaker- Compressor 1 (C07= C)


CB5
Circuit
BreakerCompressor 1 (C07= C)


CB5
Circuit
BreakerCompressor 1 (C07= C)

552
CB2
Circuit
BreakerCompressor 2 (C07= C)


CB2
Circuit
BreakerCompressor
2 (C07= C)


CB2
Circuit
BreakerCompressor
2 (C07= C)

553
CB6
Circuit
BreakerCompressor
2 (C07= C)


CB6
Circuit
BreakerCompressor
2
(C07= C)


CB6
Circuit
BreakerCompressor
2
(C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
047359315
1
047359330
1
047359346
047359315
1
047359330
1
047359346
047359315
1
047359330
1
047359346
047359315
1
047359330
1
047359346

Rev. R 07/15

RPL 571180 / Page 26

Power Panel

AGR 090A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 840MA


PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 600A


DS1
Disconnect
Switch- 250A

N/S
Power
Hub2"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372724
1
030372706
1
1
072937503
1
047442104 1 1
038683000
1
1
1

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description


533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2


M6
Compressor Contactor- Compressor 2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit
Breaker- Compressor 1 (C07= C)


CB5
Circuit
BreakerCompressor 1 (C07= C)


CB5
Circuit
BreakerCompressor 1 (C07= C)

552
CB2
Circuit
BreakerCompressor 2 (C07= C)


CB2
Circuit
BreakerCompressor
2 (C07= C)


CB2
Circuit
BreakerCompressor
2 (C07= C)

553
CB6
Circuit
BreakerCompressor
2 (C07= C)


CB6
Circuit
BreakerCompressor
2
(C07= C)


CB6
Circuit
BreakerCompressor
2
(C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
047359315
1
047359330
1
047359346
047359315
1
047359330
1
047359346
047359315
1
047359330
1
047359346
047359315
1
047359330
1
047359346

Rev. R 07/15

RPL 571180 / Page 27

Power Panel

AGR 095A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 840MA


PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 600A


DS1
Disconnect
Switch- 250A

N/S
Power
Hub2"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372724
1
030372706
1
1
072937503
1
047442104 1 1
038683000
1
1
1

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2


M6
Compressor Contactor- Compressor 2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit
Breaker- Compressor 1 (C07= C)


CB5
Circuit
BreakerCompressor 1 (C07= C)


CB5
Circuit
BreakerCompressor 1 (C07= C)

552
CB2
Circuit
BreakerCompressor 2 (C07= C)


CB2
Circuit
BreakerCompressor
2 (C07= C)


CB2
Circuit
BreakerCompressor
2 (C07= C)

553
CB6
Circuit
BreakerCompressor
2 (C07= C)


CB6
Circuit
BreakerCompressor
2
(C07= C)


CB6
Circuit
BreakerCompressor
2
(C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
047359315
1
047359330
1
047359346
047359315
1
047359330
1
047359346
047359317
1
047359332
1
047359346
047359317
1
047359332
1
047359346

Rev. R 07/15

RPL 571180 / Page 28

Power Panel

AGR 100A Components

Compressor Contactors, Compressor Circuit Breakers, Power Block, Disconnect Switches, Hubs

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

690
PB1
Power Block (C06= P)- 840MA


PB1
Power Block (C06= P)- 335MA

690
DS1
Disconnect Switch- 600A


DS1
Disconnect Switch- 250A

N/S
Power Hub- 2"

Part
Number

208/ 460V 575V


230V

Part
Number

208/ 460V 575V


230V

030372724
1
030372706
1
1
072937503
1
047442104 1 1
038683000
1
1
1

Either Starting Option (C05= AL or PW)


Ref.
No.

Schem.
Sym.

Description

533
M1
Compressor Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1


M1
Compressor
Contactor- Compressor 1

534
M5
Compressor
Contactor- Compressor 1


M5
Compressor
ContactorCompressor 1


M5
Compressor
ContactorCompressor 1

535
M2
Compressor
ContactorCompressor 2


M2
Compressor
ContactorCompressor
2


M2
Compressor
ContactorCompressor
2

536
M6
Compressor
ContactorCompressor
2


M6
Compressor
ContactorCompressor
2


M6
Compressor Contactor- Compressor 2

550
CB1
Circuit Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)


CB1
Circuit
Breaker- Compressor 1 (C07= C)

551
CB5
Circuit
Breaker- Compressor 1 (C07= C)


CB5
Circuit
BreakerCompressor 1 (C07= C)


CB5
Circuit
BreakerCompressor 1 (C07= C)

552
CB2
Circuit
BreakerCompressor 2 (C07= C)


CB2
Circuit
BreakerCompressor
2 (C07= C)


CB2
Circuit
BreakerCompressor
2 (C07= C)

553
CB6
Circuit
BreakerCompressor
2 (C07= C)


CB6
Circuit
BreakerCompressor
2
(C07= C)


CB6
Circuit
BreakerCompressor
2
(C07= C)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
072288701 1
027514407
1
027514406
047359317
1
047359332
1
047359346
047359317
1
047359332
1
047359346
047359317
1
047359332
1
047359346
047359317
1
047359332
1
047359346

Rev. R 07/15

RPL 571180 / Page 29

Control Panel Components

UNT Control Panel Diagram- Left Side


(Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD)
System
Switch

Setpoint

Circuit
No. 1

Control Band

Auto

Auto
Alarm

S1

Circuit
No. 2

102

Status

Emergency
Stop

102

100

100

Pumpdown
and Stop

101

RPS- 1

T2

Freezestat Reset

PS1

Auto

PS2

Pumpdown
and Stop

128

Wireway

F1

MPR1 MPR2 CRR1 CRR2

127

126

TC 11

Switch
Plate

UNT

F2
CB1
129

249

130 131

125

366

R9

R 10

R 21

R 22

TB 3

365

Wireway

TB 7

TB 2

TB 4

155

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Ground Bus

Rev. R 07/15

RPL 571180 / Page 30

Control Panel Components


UNT Control Panel Components- Left Side
(Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD)

Ref#
Schematic
Symbol
100 S1 / PS1 / PS2

Description

Part Number Qty.

Switch

074804401

101

Freezestat Reset Button

074804501 1

102

Potentiometer: Setpoint and Control Band

074805401 2

125

UNT

Main Controller- Johnson Controls Central Processor 074804901

126

T2

Control Circuit Transformer- 120V- 24V

074804601

127

RPS-1

Reg. Power Supply: 120VA- 5VDC

074804701 1

128 MPR1,2 / CRR1,2



129
CB1

Relay

074804801 4

Circuit Breaker

074805001 1

130

F1

Fuse- 15A

025954700 1

131

F2

Fuse- 10A

018961400

155

Ground Bus

037530800

249

R9, R10

Relay- Hot Gas Bypass

072937402

365

R21, R22

Relay- Hi Ambient Unloading

072937402

366

TC11

Temperature Control- HiWater Unloading w/bulb 074805101 1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 31

Control Panel Components

UNT Control Panel Diagram- Right Side

B08

Wireway

(Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD)

B07

B06

B05

TB 7

B04
180

B02

Wireway

Wireway

B03

TB 6

B01

Neutral Bus

156

Wireway
MPH-1
PC 12

MPH-2

PC 22
270

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

150

Rev. R 07/15

RPL 571180 / Page 32

Control Panel Components


UNT Control Panel Components- Right Side
(Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD)

Ref#
Schematic
Symbol

Description

150

Mechanical Pressure Switch

074805301

156

Neutral Bus

037530700

180
B01- B08


Output Relays
Units with 4- Stage Capacity Control (C08= 04)
Units with 6- Stage Capacity Control (C08= 06)
(note: B05, B06 are only used on 6- stage units)

074805801
074805801

6
8

270

Pressure Control- FanTrol Head Pressure

074805201 2

Zone Terminal Display Only

074805501

MPH-1, 2

PC12, PC22

N/S

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Part Number Qty.

Rev. R 07/15

RPL 571180 / Page 33

Control Panel Components


UNT Zone Terminal Display
(Code 11= J*D)

930

128

931

Ref#

Description

128

Channel w/o Convenience Outlet (C13= Y) 074710202 1


Channel with Convenience Outlet (C13= C) 074710201 1

930

Mounting Bracket- Zone Terminal

074712801 1

931


Zone Terminal Kit


(kit includes- Zone Terminal, Cable and Bracket)
Zone Terminal Cable
Terminal Bracket

074690001

074805601
074805701

1
1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Part Number

Rev. R 07/15

Qty.

RPL 571180 / Page 34

Control Panel Components


UNT Control Panel Components
Unit Mounted Sensors & Controls, Solenoid Valve Junction Box
(Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD)

Diagrams

Top View
S09

OAT

See Detail 2

LP1 (circuit 1)
S08

S01

EWT (optional)

See Detail 3

See Detail 1

LP2 (circuit 2)
S02
See Detail 1

S00 LWT (standard)

Detail 1

See Detail 3

S01 or S02

Detail 3

Evaporator
Water Temperature
Sensor

750
S08 or S00

Shrader fitting on
compressor

830
SV1

SV2

834
Detail 2
(Back of Control Box)

793

793

Junction BoxSV1, SV2,


Evap. Heater
788

841

841

S09

791

789

831

From Control Box


PC22- see control panel for PN

PC12- see control panel for PN

840
751
High Pressure
Staging Control
View from back of control box

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 35

Control Panel Components


UNT Control Panel
Unit Mounted Sensors & Controls, Solenoid Valve Junction Box
(Code 11= JYY, JZY, JRY, JDY, JYD, JZD, JRD, or JDD)

Components

Controls and Hardware


Ref#
Description
Part Number Qty.
751
Hi-Pressure Fan Staging Control
073074003
2
N/S
Pressure Control- Hi Ambient Unloading 073074005
2
788
Junction Box
047359001
1
789
Junction Box Cover
047359002
1
791
Conduit Fitting- 1/2"
001127500 1
793
Conduit Fitting- 3/8"
001127600
2
830
Fitting- .25"
735048015
1
831
Well- Evap Nozzle
047441506
1
834
Bulb Paste
735026315
N/A
840
Bushing
028387000
6
841
Outside Air Sensor Clamp
735045630
2

Sensors
Ref#
S01, S02




750

Description
Part Number
L.P. Transducer @ Compressor
Sensor Cable Assembly
074667501
Includes wires, boot, terminals, connector
Connector only
074609001
Transducer Boot
071583301
Low Pressure Transducer
065816801

S08 or S00

Leaving or Entering Water


Temperature Sensor

070312401

S09

Outdoor Air Temperature Sensor

070312401

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

Qty.
2
1
1
2

RPL 571180 / Page 36

Control Panel Components


MicroTech Control Panel Diagram- Left Side
(Code 11= MAY, MCY, MDY, MYY)

MHPR

260

MPR

MPR

MPR

MHPR

R9

MPR

R 10

249

Wireway
TB4

231

905

M250 10BT

ADI

970
971
972

904

974
976

903
902
215

912

F1 CB

T4

212

F2

T2

NB

211
179 210

TB7

244

213

231

Wireway
TB2
231

TB3
NB

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

231

243

Rev. R 07/15

RPL 571180 / Page 37

Control Panel Components


MicroTech Control Panel Components- Left Side
(Code 11= MAY, MCY, MDY, MYY)

Ref#
Schematic
Symbol
179
210
F1
211
212
F2
213
T2
215
T4
231 TB2, TB3, TB4, TB7
243
NB
244
NB
249
R9, R10
260 MHPR1,2, MPR1,2,3,4
902
M250
903
904
ADI
905
N/S

912
CB
970


971
972
974
976
N/S

Description

Part Number

Bracket for F1, F2, CB


Fuse- 15A
Fuse Holder for F1, F2
Fuse- 10A
Transformer: 120V- 24V
Transformer: 24V- 18V
Terminal Block- 16 Terminals
Neutral Block- 7 Pole
Neutral Block- NE16P
Relay- SPDT 30A Hot Gas Bypass (C09= 2)
Relay- 1PDT, 30A
Controller M250 (must be programmed)
M250 Mounting Channel
ADI Board
Ribbon Cable
Varistor Ass'y- 30V
Varistor Only
Circuit Breaker
Modem Kit (w/cord set) (C26= *M*)
Modem Only
Cord Set Only
Modem Interface Cable
Gasket
Modem Bracket
Modem Bracket- Vertical
Alarm Bell (Mounted on Outside of Control Box)

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

Qty.

072969701
1
025954700 1
018690600
2
018961400
1
060630801
1
046738114
1
022431216
4
037530800
1
037530700
1
072937402
2
072937402
6
065487306
1
055727201 1
065816001
1
065499704
1
072119410
1
049759701
1
735073301
1
063585005
1
059476901
1
059476701
1
074355603
1
070199207 1
073043505
1
073014701
1
017809400
1

RPL 571180 / Page 38

Control Panel Components


MicroTech Control Panel Diagram- Right Side
(Code 11= MAY, MCY, MDY, MYY)

900
901

TB8

251

907

TB5

231

Wireway
TB6

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

231

Rev. R 07/15

RPL 571180 / Page 39

Control Panel Components


MicroTech Control Panel Components- Right Side
(Code 11= MAY, MCY, MDY, MYY)

Ref#
Schematic
Symbol
231
TB5, TB6

Description

Part Number

Qty.

Terminal Block- 16 Terminals

022431216

251

Terminal Block- 9 Terminals

022431209

Output Board

049265501

901
Output Board Relays
AGR055- 070: 6 Steps Capacity (C08= 06)
AGR055- 070: 4 Steps Capacity (C08= 04)
AGR075- 100: 6 Steps Capacity (C08= 06)
AGR075- 100: 4 Steps Capacity (C08= 04)

049265601
049265601
049265601
049265601

14
12
16
14

907

049265201

TB8

900

Ribbon Cable

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 40

Control Panel Components


MicroTech Control Panel Keypad Display
(Code 11= MAY, MCY, MDY, MYY)

959

959

CIRCUIT
NO. 1

SYSTEM
SWITCH

CIRCUIT
NO. 2

ALARM

PUMPDOWN
AND STOP

STOP

960

PUMPDOWN
AND STOP

955

956


Part
Ref. No.
Description
Number
Qty.
955
Keypad Label
071742502 1

956
Keypad
Display
065497201
1

959
Switch125V
071995301
3

960
Red LED Lamp
065810801
1

N/S
Mounting
Channel
with
Outlet
(C13=C)
074705402
1

N/S
Mounting Channel w/o Outlet (C13=Y)
074705401
1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 41

Control Panel Components


MicroTech Control Panel Components
Unit Mounted Sensors & Controls, Solenoid Valve Junction Box
(Code 11= MAY, MCY, MDY, MYY)

Diagrams

Top View

S14

See Detail 4

S12

S13
S15

S09

S03

See Detail 2

See Detail 1

S08

S01

See Detail 3

See Detail 1

S04
See Detail 1

S02
See Detail 1

S00
See Detail 3

S03 or S04

Detail 1

Detail 3

S01 or S02
Detail 4

750 or 749
Shrader fitting on
compressor

S12

563 834

S14

S13

S15

Detail 2
(Back of Control Box)

841

Evaporator
Water Temperature
Sensor

S08 or S00

841

830
834

831

S09
Junction BoxSV1, SV2,
Evap. Heater
SV1
793

SV2
793

View from back of control box

840
788
789

791
From Control Box

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 42

Control Panel Components


MicroTech Control Panel
Unit Mounted Sensors & Controls, Solenoid Valve Junction Box
(Code 11= MAY, MCY, MDY, MYY)

Components

Controls and Hardware


Ref#
Description
Part Number Qty.
563
Sensor Tube- Suction and Liquid Tube Sensors 070228901
4
788
Junction Box
047359001
1
789
Junction Box Cover
047359002
1
791
Conduit Fitting- 1/2"
001127500 1
793
Conduit Fitting- 3/8"
001127600
2
830
Fitting- .25"
735048015
1
831
Well- Evap Nozzle
047441506
1
834
Bulb Paste
735026315 N/A
840
Bushing
028387000
6
841
Outside Air Sensor Clamp
735045630
2

Sensors
Ref#
S00
S01 (750)
S02 (750)
S03 (749)
S04 (749)
S08
S09
S10 (N/S)
S12
S13
S14
S15

Description
Part Number Qty.
Evap. Leaving Water Temp. 30' Lead
073012003 1
Low Pressure Transducer: Circuit #1
065816801 1
Low Pressure Transducer: Circuit #2
065816801 1
High Pressure Transducer: Circuit #1
065816802 1
High Pressure Transducer: Circuit #2
065816802 1
Evap. Entering Water Temp. 10' Lead
073012001 1
Outside Air Temp. 10' Lead
073012001 1
Unit % Amps (See SC Control in Control Box- Left Side)
Suction Line Temp. Circuit #1 10' Lead
073012001 1
Suction Line Temp. Circuit #2 10' Lead
073012001 1
Liquid Line Temp. Circuit #1 10' Lead
073012001 1
Liquid Line Temp. Circuit #2 10' Lead
073012001 1

Cables
Cable Cable
Cable Sensors
Type
Part Number
Terminus
Included
J13
074355601
1, 2
None
POWER
074355602
3, 5
None
COM
074355610
4, 5
None
ADI- AH1
074355604
1, 2
S00, 01, 02, 03
ADI- AH2
074355605
1, 2
S04
ADI- AH3
074355606 (Code 26= **R or **B) 1, 2
S08, S09
ADI- AH3
074355616 (Code 26= **D or **C) 1, 2
S08, S09, S10
ADI- AH4
074355607 (Code 26= **B or **C) 1, 2
S12, S13, S14, S15
ADI- DH1
074355618
1, 2
None
ADI- DH2
074355619
1, 2
None
Terminus Key: 1= 9 pole Terminal block pn: 065499909; 2= Terminal block cover
pn: 065500009; 3= Terminal Hsg, Female 4-Pin pn: 049264502; 4= Terminal Hsg.
Female 6-Pin pn: 049264502; 5= Terminal Pin (qty. 3) pn: 049264702.
Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 43

Control Panel Components


Speedtrol Components (C18= S)
UNT or MicroTech Controls
807

820

811
809

806
3

822


Part
Ref. No.
Description
Number
Qty.
1
P66 Speedtrol Control
048445202
2*

2
Strap- Capacitor
330577701
2*

3
Capacitor- 30MFD, 440V
037516429
2*
806
Speedtrol Box- Circuit One
074308951
1

807
Speedtrol
BoxCircuit
Two
074308952
1

809
Transformer- 575V Only (C04= 37)
037533619
1

811
Bracket575V
Only
(C04=
37)
074717401 1

820
Angle- Speedtrol Boxes
074716301
1

822
Bottom Support Bracket
074891301
1

N/S
Weather Cover- Speedtrol Boxes
074716401
1

*Included in Speedtrol Boxes (806 & 807). Quantity is one per box.

Convenience Outlet (C13= C) and Gauges (C23= A)


UNT or MicroTech Controls


Part
Ref. No.
Description
Number
Qty.
N/S
Convenience
Outlet
Receptacle
025283700
1

N/S
Convenience Outlet Fuse- 10A
018961400
1

N/S
Convenience Outlet Fuse Holder- 15A
018690600
1


N/S
Discharge Gauge- 800#
040159300
1

N/S
Suction
and
Oil
Gauges150#
017503500
2

N/S
Gauge
Shutoff
Valve
046742601
6

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 44

Condenser Section
AGR055, 060A

Fan and Motor


Cross Section- Typical

709

708

713

See Detail 'A'

648

680
679
679

Detail 'A'

B50

B84

700

B93

704

Motor Mount

B50

679
B93

679
705

701
B83 B14

B03
Fan Deck

680

707

676

673

671
677

674

672
Coil Blockoff Panels
055- 070
Side ViewL.H. Shown

Coils
End View- Opposite
Control Box End

691

690
687

688

6
*

Circuit 2

Circuit 1

*
9

693

694

8
695

692

* Discharge header connection


NOTE: The coil hand (left or right) is based on the discharge header connection point.
Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 45

Condenser Section

AGR065, 070, 075, 080, 085, 090, 095, 100A


Fan and Motor
Cross Section- Typical

708

713

709

See Detail One

648

680
679

Detail One

B50

B84

679
B93

B50

Motor Mount

Fan Deck

704

679
705

701

700

B03

680

707

B83 B14

679
B93

676

673

671
677

674

672

Coil Blockoff Panels


075- 100
Side ViewL.H. Shown
Coils
End View- Opposite
Control Box End

690

691

6
728

Circuit 2

Circuit 1

*
8

726

C.B. end

693

9
694

727

opp.
C.B. end

695

692

* Discharge header connection


NOTE: The coil hand (left or right) is based on the discharge header connection point.
Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 46

Condenser Section

Components- Condenser Fan Deck (less motors)


Condenser Fan Components- AGR055, 060, 065A

Ref#
Qty. Description
Part Number

648
4 Fan Deck Panel 074702701

679
16
Venturi Plate
074680301

680
8
Venturi
Angle
074680401

1
704
Motor Mount- 1.5 HP Motors
074711601

1
705

Motor
Mount1.0
HP
Motors 074711501

707
4 Rain Slinger 027471200

2
708
Fan Prop 28"- 1.5 HP Motors
072941302

2
709

Fan
Prop
28"1.0
HP
Motors 072972201

713
4 Fan Grille 32"
071755601

1.5HP is the standard motor, 1.0 HP is the Speedtrol Motor. For Units with
Speedtrol (C18= S) use 2- 1.5 HP motors and 2- 1.0 HP motors. Units without
Speedtrol (C18= F) use 4- 1.5 HP motors. Quantity is 2 per motor.
2
709 Fan Prop. is used with Speedtrol Motors. 708 is used with standard 1.5 HP
motor. See note one for quantity information.
1

Condenser Fan Components- AGR070A

Ref#
Qty. Description
Part Number

648
4
Fan
Deck
Panel 074702701

679
16 Venturi Plate
074680301

680
8 Venturi Angle
074680401

1
704

Motor
Mount2.0
HP
Motors
074711601

1
705
Motor Mount- 1.0 HP Motors 074711501

707
4
Rain Slinger 027471200

2
708

Fan Prop 28"- 2.0 HP Motors
073061401

2
709
Fan Prop 28"- 1.0 HP Motors 072972201

713
4
Fan Grille 32"
071755601

2.0HP is the standard motor, 1.0 HP is the Speedtrol Motor. For Units with
Speedtrol (C18= S) use 2- 2.0 HP motors and 2- 1.0 HP motors. Units without
Speedtrol (C18= F) use 4- 2.0 HP motors. Quantity is 2 per motor.
2
709 Fan Prop. is used with Speedtrol Motors. 708 is used with standard 2.0 HP
motor. See note one for quantity information
1

Condenser Fan ComponentsAGR075, 80, 085, 090, 095, 100A

Ref#
Qty. Description
Part Number

648
6
Fan
Deck
Panel 074702701

679
24 Venturi Plate
074680301

680
12 Venturi Angle
074680401

1
704

Motor
Mount2.5
HP
Motors
074711601

1
705
Motor Mount- 1.0 HP Motors 074711501

707
4 Rain Slinger 027471200

2
708
Fan Prop 28"- 2.0 HP Motors
073061401

2
709
Fan Prop 28"- 1.0 HP Motors 072972201

713
6
Fan Grille 32"
071755601

2.0HP is the standard motor, 1.0 HP is the Speedtrol Motor. For Units with
Speedtrol (C18= S) use 4- 2.0 HP motors and 2- 1.0 HP motors. Units without
Speedtrol (C18= F) use 6- 2.0 HP motors. Quantity is 2 per motor.
2
709 Fan Prop. is used with Speedtrol Motors. 708 is used with standard 2.0 HP
motor. See note one for quantity information
1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 47

Condenser Section

Components- Condenser Fan Motors

Motors- AGR 055- 065A

Ref#
Qty. Description
Part Number

1
701
Standard 1.5 HP Motor (C20= 1)


208/230/460V
072937601


575V
046744200

1
701
Totally- Enclosed 1.5 HP Motor (C20= 2)


208/230/460V
073000501


575V
N/A

700 1 Speedtrol 1.0 HP Motor

All Voltages
070989600

When Speedtrol is used (C18= S) Quantity of Motors is 2 of each type. Standard


Units (C18= F) use 4 each of the 1.5 HP Motor.

Motors- AGR 070A

Ref#
Qty. Description
Part Number

1
701
Totally- Enclosed 2.0 HP Motor (C20= 2)


208/230/460V
073018701


575V
N/A


1
700
Speedtrol 1.0 HP Motor


All Voltages
070989600

When Speedtrol is used (C18= S) Quantity of Motors is 2 of each type. Standard
Units (C18= F) use 4 each of the 2.0 HP Motor. 2.0 HP motors are only available
in Totally Enclosed form.

Motors- AGR 075- 100A

Ref#
Qty. Description
Part Number

1
701

TotallyEnclosed
2.0
HP
Motor
(C20=
2)


208/230/460V
073018701


575V
N/A


1
700
Speedtrol 1.0 HP Motor


All Voltages
070989600

When Speedtrol is used (C18= S) Quantity of Motors is 2 Speedtrol and 4 standard motors. Standard Units (C18= F) use 6 each of the 2.0 HP Motor. 2.0 HP
motors are only available in Totally Enclosed form.

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 48

Condenser Section

Components- Sheet Metal and Hardware


Sheet Metal- AGR055, 060A
Ref#
Qty.

671
1

672
1

673
1

674
1

676
1

677
1

687
1

688
1

690
1

691
1

692
1

693
1

694
2

695
2

Description
Part Number
Rear Blockoff Panel- R.H. Coil 074592701
Rear Blockoff Panel- L.H. Coil 074592702
Front Blockoff Panel- R.H. Coil 074592501
Front Blockoff Panel- R.H. Coil 074592502
Middle Blockoff Panel- R. H. Coil
074592601
Middle Blockoff Panel- L. H. Coil
074592602
Top Coil Support- R.H. Coil 074592401
Top Coil Support- L.H. Coil 074592402
Cable Trough- R.H. Coil 074591701
Cable Trough- L.H. Coil 074591702
Side Rail- R.H. Coil
074591601
Side Rail- L.H. Coil
074591602
Cross Brace 074591801
Cross Brace
074591602

Sheet Metal- AGR065, 070A


Ref#
Qty.

671
1

672
1

673
1

674
1

676
1

677
1

690
1

691
1

692
1

693
1

694
2

695
2

726
1

727 1
728 2

Description
Part Number
Rear Blockoff Panel- R.H. Coil
074596701
Rear Blockoff Panel- L.H. Coil
074596702
Front Blockoff Panel- R.H. Coil
074596501
Front Blockoff Panel- R.H. Coil
074596502
Middle Blockoff Panel- R. H. Coil
074596601
Middle Blockoff Panel- L. H. Coil
074596602
Cable Trough- R.H. Coil 074591701
Cable Trough- L.H. Coil 074591702
Side Rail- R.H. Coil
074591601
Side Rail- L.H. Coil
074591602
Cross Brace 074591801
Cross Brace
074591602
Coil Support Bracket- C.B. End 074718001
Coil Support Bracket- Opp. C.B.End 074718101
Angle/Coil Support Bracket 074884401

Hardware- 055, 060, 065, 070A


Ref#
Qty. Description

B03 * Screw
B14
16 Screw

B50
16 Flat Washer

B83
16 Lock Nut

B84
16 Lock Nut

B93 48 Washer
*varies

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Part Number
046093807
040499035
040500316
074635402
074635403
074635301

Rev. R 07/15

RPL 571180 / Page 49

Condenser Section

Components- Sheet Metal and Hardware


Sheet Metal- AGR075, 080, 085, 090, 095, 100A
Ref#
Qty.

671
1

672
1

673
1

674
1

676
2

677
2

690
1

691
1

692
1

693
1

694
2

695
2

726
1

727
1

728
2

Description
Part Number
Rear Blockoff Panel- R.H. Coil
074596701
Rear Blockoff Panel- L.H. Coil
074596702
Front Blockoff Panel- R.H. Coil
074596501
Front Blockoff Panel- R.H. Coil
074596502
Middle Blockoff Panel- R. H. Coil
074596601
Middle Blockoff Panel- L. H. Coil
074596602
Cable Trough- R.H. Coil 074591701
Cable Trough- L.H. Coil 074591702
Side Rail- R.H. Coil 074597801
Side Rail- L.H. Coil 074597802
Cross Brace 074591801
Cross Brace 074591802
Coil Support Bracket- C.B. End 074718001
Coil Support Bracket- opp. end 074718101
Angle/Coil Support 071884401

Hardware- 075, 080, 085, 090, 095, 100A


Ref#
Qty. Description

B03 * Screw
B14
32 Screw

B50
48 Flat Washer

B83
32 Lock Nut

B84
24 Lock Nut

B93 72 Washer
*varies

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Part Number
046093807
040499035
040500308
074635402
074635403
074635301

Rev. R 07/15

RPL 571180 / Page 50

Condenser Section
Components- Coils

Condenser Coils
AGR055, 060A
Aluminum Fin (C19= 11)
Ref#

6
7
8
9

Description
Coil- RH
Coil- LH
Coil- LH
Coil- RH

Part No.
074356003
074356013
074356013
074356003

Condenser Coils
AGR065, 070A
Aluminum Fin (C19= 11)
Ref#

6
7
8
9

Description
Coil- RH
Coil- LH
Coil- LH
Coil- RH

Part No.
074356004
074356014
074356014
074356004

Condenser Coils
AGR075, 080, 085, 090, 095, 100A
Aluminum Fin (C19= 11)
Ref#

6
7
8
9

Description
Coil- RH
Coil- LH
Coil- LH
Coil- RH

Part No.
074356005
074356015
074356015
074356005

Condenser Coils
AGR055, 060A
Copper Fin (C19= 21)
Ref#

6
7
8
9

Description
Coil- RH
Coil- LH
Coil- LH
Coil- RH

Part No.
074356023
074356033
074356033
074356023

Condenser Coils
AGR065, 070A
Copper Fin (C19= 21)
Ref#

6
7
8
9

Description
Coil- RH
Coil- LH
Coil- LH
Coil- RH

Part No.
074356024
074356034
074356034
074356034

Condenser Coils
AGR075, 080, 085, 090, 095, 100A
Copper Fin (C19= 21)
Ref#

6
7
8
9

Description
Coil- RH
Coil- LH
Coil- LH
Coil- RH

Part No.
074356025
074356035
074356035
074356025

NOTE: The coil hand (left or right) is based on the discharge header connection point.

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 51

Cabinet

Panels, Control/Power Doors, Hardware- All Unit Sizes


Diagrams
(Four Fan Unit shown)

870

874

B03

B03

875

B04 B03

B03
871

B04 B91 B03 887

886
B03 873

43
891

896
895

58

894

both
sides

889
890

B01
888

893

B03

896
42

895
880

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 52

Cabinet

Panels, Control/Power Doors, Hardware


Components
Ref.
No.



Part
Number

Description

Qty.

B01
Screw
046093802

B03
Screw
046093807

B04
Screw
046093809

B91
Gasket
070199201

48
200+
16
6 ft.


42

43

58


870


Front Corner Post- Right Hand


Front Corner Post- Left Hand
Rear Corner Post- L.H. & R.H.

074702501
1
074702401 1
074702301
2

Corner Panel, Back- L.H. AGR055, 060A


Corner Panel, Back- L.H. AGR065- 100A

074594302
074598602

1
1

871

Corner Panel, Back- R.H. AGR055, 060A


Corner Panel, Back- R.H. AGR065- 100A

074594301
074598601

1
1


873


Corner Panel, Front- L.H. AGR055, 060A 074593702


Corner Panel, Front- L.H. AGR065- 100A 074599402

1
1

Top Panel, Rear AGR065- 100A only


874


875

074714601

Louvered Back Panel AGR055, 060A 074594201 1


Louvered Back Panel AGR065- 100A 074598701 1

880
886


887




888

889

890
891
893


R.H. Power Panel Door


074707801 1
Top Panel, Front AGR065- 100A only 074714701 1

894
895
896

Hinge- 2"
Fastener- Door
Lock w/Key

Front Panel
Front Panel

AGR055, 060A
AGR065- 100A

074593801
074599301

1
1

L.H. Power Panel Door


074707701 1
Dead Door Reinforcement
074708801 1
Control Panel Dead Door
074708701 1
Control Panel Door
074707101 1
Corner Panel, Front- R.H. AGR055, 060A 074593701
1
Corner Panel, Front- R.H. AGR065- 100A 074599401
1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

032457700
2
047135602
3
001157200 2

Rev. R 07/15

RPL 571180 / Page 53

Cabinet

Coil Guards, Base Frame Guards, Hardware


Diagram
(AGR 055- 070A Shown)

903

925

905 B03
54
55

B03

56

B03

B03

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

901

907

Rev. R 07/15

B03

B03

RPL 571180 / Page 54

Cabinet

Coil Guards, Base Frame Guards, Hardware


Components
AGR 055, 060, 065, 070A
Base Frame Guards (C17= A)
With Gauges (C23=B)
Ref.
No.







Part
Number

Description

Qty.

B03
Screw
046093807 8/guard

54
BracketRear
Grille
Support
074710501 1

55
Support- Base Grille
074715001 1

56
Support- Base Grille with Gauge Holes 074714801 1

901
Grille- Base, Unit Sides
046739301
4

905
Grille Filler Channel
074710701 4

907
GrilleBase,
Rear
w/90
Bend
074514201 2

925
Back Rail
074593901
1

Base Frame Guards (C17= A)


Without Gauges (C23=Y)
Ref.
No.






Part
Number

Description

Qty.

B03
Screw
046093807 8/guard

54
BracketRear
Grille
Support
074710501 1

55
Support- Base Grille
074715001 2

901
Grille- Base, Unit Sides
046739301
4

905
Grille
Filler
Channel
074710701 4

907
Grille- Base, Rear w/90 Bend
074514201 2

925
Back
Rail
074593901
1

Vertical Condenser Coil Guards (C17= G)


With or Without Gauges (C23= B or Y)
Ref.
No.

Description

Part
Number

Qty.

903
Coil Guard- AGR055, 060A
049119301
4


Coil
GuardAGR065,
070A
074711401 4

925
Back Rail
074593901
1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 55

Cabinet

Coil Guards, Base Frame Guards, Hardware


Components
AGR 055, 060, 065, 070A
Base Frame Guards and Vertical Coil Guards (C17= F)
With Gauges (C23=B)
Ref.
No.

Description

Part
Number

Qty.

B03
Screw
046093807 8/guard

54
Bracket- Rear Grille Support
074710501 1

55
SupportBase
Grille
074715001 1

56
Support- Base Grille with Gauge Holes 074714801 1

901
Grille- Base, Unit Sides
046739301
4

903
Coil
GuardAGR055,
060A
049119301
4


Coil Guard- AGR065, 070A
074711401 4

905
Grille Filler Channel
074710701 4

907
Grille- Base, Rear w/90 Bend
074514201 2
925
Back Rail
074593901
1

Base Frame Guards and Vertical Coil Guards (C17= F)


Without Gauges (C23=Y)
Ref.
No.

Description

Part
Number

Qty.

B03
Screw
046093807 8/guard

54
BracketRear
Grille
Support
074710501 1

55
Support- Base Grille
074715001 2

901
GrilleBase,
Unit
Sides
046739301
4

903
Coil
GuardAGR055,
060A
049119301
4


Coil Guard- AGR065, 070A
074711401 4

905
Grille
Filler
Channel
074710701 4

907
Grille- Base, Rear w/90 Bend
074514201 2

925
Back Rail
074593901
1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 56

Cabinet

Coil Guards, Base Frame Guards, Hardware


Components
AGR 075, 080, 085, 090, 095, 100A
Base Frame Guards (C17= A)
With Gauges (C23=B)
Ref.
No.







Part
Number

Description

Qty.

B03
Screw
046093807 8/guard

54
BracketRear
Grille
Support
074710501 1

55
Support- Base Grille
074715001
3

56
SupportBase
Grille
with
Gauge
Holes 074714801
1

901
GrilleBase,
Unit
Sides
046739301
6

905
Grille Filler Channel
074710701
6

907
GrilleBase,
Rear
w/90
Bend
074514201 2

925
Back Rail
074593901
1

Base Frame Guards (C17= A)


Without Gauges (C23=Y)
Ref.
No.






Part
Number

Description

Qty.

B03
Screw
046093807 8/guard

54
BracketRear
Grille
Support
074710501 1

55
Support- Base Grille
074715001 4

901
Grille- Base, Unit Sides
046739301
6

905
Grille
Filler
Channel
074710701
6

907
Grille- Base, Rear w/90 Bend
074514201 2

925
Back
Rail
074593901
1

Vertical Condenser Coil Guards (C17= G)


With or Without Gauges (C23= B or Y)
Ref.
No.

Description

Part
Number

Qty.

903
Coil Guard
049119301



925
Back Rail
074593901

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

6
1

RPL 571180 / Page 57

Cabinet

Coil Guards, Base Frame Guards, Hardware


Components
AGR 075, 080, 085, 090, 095, 100A
Base Frame Guards and Vertical Coil Guards (C17= F)
With Gauges (C23=B)
Ref.
No.








Description

Part
Number

Qty.

B03
Screw
046093807 8/guard

54
Bracket- Rear Grille Support
074710501 1

55
SupportBase
Grille
074715001 5

56
Support- Base Grille with Gauge Holes 074714801 1

901
Grille- Base, Unit Sides
046739301
6

903
Coil
Guard
074711401
6

905
Grille Filler Channel
074710701
6

907
Grille- Base, Rear w/90 Bend
074514201 2

925
Back Rail
074593901
1

Base Frame Guards and Vertical Coil Guards (C17= F)


Without Gauges (C23=Y)
Ref.
No.







Description

Part
Number

Qty.

B03
Screw
046093807 8/guard

54
BracketRear
Grille
Support
074710501 1

55
Support- Base Grille
074715001 4

901
GrilleBase,
Unit
Sides
046739301
6

903
Coil Guard
049119301
6

905
Grille Filler Channel
074710701
6

907
GrilleBase,
Rear
w/90
Bend
074514201 2

925
Back Rail
074593901
1

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 58

Piping Components
Diagrams

Discharge Lines
D53

D07

D39

D07

D53

D09

D51

Suction Lines
L07
L06

S04

L05
TXV
Line Detail

L04
L01

L02

L13

Liquid Lines

L12
L11

L14

L13
L12

L14

See TXV
Line Detail

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

L11

L01 L02

Rev. R 07/15

RPL 571180 / Page 59

Piping Components
Components

AGR 055A, 060A


Ref.
No.

Description

Part
Number

Qty.

D07
Relief Valve
039441300
2

D09
Muffler- 1.625" Connection
047664305
2

D39
Muffler
Bracket
074684501
2

D51
Hot Gas Valve- Electronic 120V
074696802*
2

D53
Hot Gas Shutoff Valve- 1.125"
019282100 2


L01
Valve Core
026541100
2

L02
Valve
Cap
039242300
2

L04
Sight
Glass
Saddle
025329600
2

L05
Sight Glass
022427700 2

L06
Expansion
Valve30
Ton
030569103
2

L07
Solenoid
Valve.875"
047931303
2

L11
Filter Drier
001360700 +
2

L12
Filter
Drier
Core
070339101+
2

L12
Filter Drier Gasket Kit
074783601 +
2
L13
Shut Off Valve- .875"
032193502
2
L14
Charge
Valve.375"
X
.375"
038689900
2

S04

Shut Off Valve

735039918

* Note: This valve is only used when Hot Gas Bypass is installed (C09= 2).
+ Note: These components are only used when Replaceable Core Filter Driers
are selected (C14= R).

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 60

Piping Components
Components

AGR 065A, 070A


Ref.
No.

Description

Part
Number

Qty.

D07
Relief Valve
039441300
2

D09
Muffler- 1.625" Connection
047664305
2

D39
Muffler
Bracket
074684501
2

D51
Hot Gas Valve- Electronic 120V
074696802*
2

D53
Hot Gas Shutoff Valve- 1.125"
019282100 2


L01
Valve Core
026541100
2

L02
Valve
Cap
039242300
2

L04
Sight
Glass
Saddle
025329600
2

L05
Sight Glass
022427700 2

L06
Expansion
Valve36
Ton
074539201
2

L07
Solenoid
Valve.875"
047931303
2

L11
Filter Drier
001360700 +
2

L12
Filter
Drier
Core
070339101+
2

L12
Filter Drier Gasket Kit
074783601 +
2
L13
Shut Off Valve- .875"
032193502
2
L14
Charge
Valve.375"
X
.375"
038689900
2

S04

Shut Off Valve

735039918

* Note: This valve is only used when Hot Gas Bypass is installed (C09= 2).
+ Note: These components are only used when Replaceable Core Filter Driers
are selected (C14= R).

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 61

Piping Components
Components

AGR 075A
Ref.
No.

Description

Part
Number

Qty.

D07
Relief Valve
039441300
2

D09
Muffler- 1.625" Connection
047664305
2

D39
Muffler
Bracket
074684501
2

D51
Hot Gas Valve- Electronic 120V
074696802*
2

D53
Hot Gas Shutoff Valve- 1.125"
019282100 2


L01
Valve Core
026541100
2

L02
Valve
Cap
039242300
2

L04
Sight
Glass
Saddle
025329600
2

L05
Sight Glass
022427700 2

L06
Expansion
Valve40
Ton
030569001
2

L07
Solenoid
Valve.875"
047931303
2

L11
Filter Drier
001360700 +
2

L12
Filter
Drier
Core
070339101+
2

L12
Filter Drier Gasket Kit
074783601 +
2
L13
Shut Off Valve- .875"
032193502
2
L14
Charge
Valve.375"
X
.375"
038689900
2

S04

Shut Off Valve

735039918

* Note: This valve is only used when Hot Gas Bypass is installed (C09= 2).
+ Note: These components are only used when Replaceable Core Filter Driers
are selected (C14= R).

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 62

Piping Components
Components

AGR 080A
Ref.
No.




Description

Part
Number

Qty.

D07
Relief Valve
039441300
2

D09
Muffler- 1.625" Connection
047664305
2

D39
Muffler
Bracket
074684501
2

D51
Hot Gas Valve- Electronic 120V
074696802*
2

D53
Hot Gas Shutoff Valve- 1.125"
019282100 2


L01
Valve Core
026541100
2

L02
Valve
Cap
039242300
2

L04
Sight
Glass
Saddle
025329600
2

L05
Sight Glass
022427700 2

L06
Expansion
Valve

Circuit One: 40 Ton
030569001
1

Circuit One: 55 Ton
030569006
1
L07
Solenoid
Valve.875"
047931303
2

L11
Filter Drier- Circuit #1
001360700 +
1

L12
Filter
Drier
CoreCircuit
#1
070339101+
1

L12
Filter Drier Gasket Kit- Circuit #1
074783601 +
1
L11
Filter Drier- Circuit #2
019190500 +
1

L12
Filter Drier Core- Circuit #2
070339101+
2
L12
Filter Drier Gasket Kit- Circuit #2
074783601 +
2
L13
Shut Off Valve- .875"
032193502
2

L14
Charge Valve- .375" X .375"
038689900
2
S04

Shut Off Valve

735039918

* Note: This valve is only used when Hot Gas Bypass is installed
(C09= 2).
+ Note: These components are only used when Replaceable Core Filter Driers
are selected (C14= R).

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 63

Piping Components
Components

AGR 085A, 090A, 095A, 100A


Ref.
No.

Description

Part
Number

Qty.

D07
Relief Valve
039441300
2

D09
Muffler1.625"
Connection
047664305
2

D39
Muffler Bracket
074684501
2

D51
Hot Gas Valve- Electronic 120V
074696802*
2

D53
Hot
Gas
Shutoff
Valve1.125"
019282100 2


L01
Valve Core
026541100
2

L02
Valve
Cap
039242300
2

L04
Sight Glass Saddle
025329600
2

L05
Sight
Glass
022427700 2

L06
Expansion Valve- 55 Ton
030569006
2

L07
Solenoid Valve- .875"
047931303
2

L11
Filter
Drier
019190500
+
2

L12
Filter Drier Core
070339101+
4

L12
Filter Drier Gasket Kit
074783601 +
4
L13
Shut Off Valve- .875"
032193502
2
L14
Charge Valve- .375" X .375"
038689900
2

S04

Shut Off Valve

735039918

* Note: This valve is only used when Hot Gas Bypass is installed (C09= 2).
+ Note: These components are only used when Replaceable Core Filter Driers
are selected (C14= R).

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 64

Evaporator

Complete Assemblies and Components


Shell and Tube Evaporators- Complete Assemblies
Unit
Model
Assembly
Suction
Liquid
Water
Size
Number
Part Number
O.D.
O.D.
Nozzle
O.D.

055, 060, 065
E1204D2
074676401
2.125"
1.375"
4"
070

E1204D1

074676501

2.125"

1.375"

5"

075, 080, 085

E1255D1

074714301

2.625"

1.375"

5"

090, 095, 100

E1455D1

074714201

2.625"

1.375"

5"

All Evaps have 300 Psig. Refrigerant Design Pressure and


175 Psig. Water Design Pressure

Components
Model Head Conn. Cond. Water Water Heater
Number Gaskets
Head
Tube
Connection Coupling 420W, 120V

Coupling Gasket
E1204D2
**
070193904 070194004 735079719
(2) (2) (1)
E1204D1
**
735049324 070194008 735079719
(2) (2) (1)

E1255D1
**
735049324 070194008 735079719
(2) (2) (1)
(1)
E1455D1
**
735049324 070194008 735079719
(2) (2) (1)

**The tubes in this evaporator are internally rolled and cannot be replaced in the field. The
evaporator must be replaced.
Water Connections

Connection
Head
Suction
Connection
Liquid
Connection

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 65

Vibration Isolators
Part Numbers- Location

Control Box

AGR 055- 100A


4
1

3
2

Ref# Qty.
1 1

Description
Spring Isolator

Part Number
047792932

2 1
Spring Isolator

3 1
Spring Isolator
4 1

047792932
047792932

Spring Isolator

047792932

Flow Switch
Description
Part Number
Flow Switch- 150PSI, Paddle Type 017503300
May be used in pipe sizes 3" to 8"

Field Installed Accessory

Flow

Alarm Bell

Mounting Plate

Control Box- Side

Alarm Bell Kit


Field Installed Accessory
Description
Part Number
Alarm Bell Kit Includes:
Alarm Bell, Mounting Plate, Hardware 058090100

Air Cooled Global Recip.Chiller, AGR 055-100 Vintage A

Rev. R 07/15

RPL 571180 / Page 66

Critical Daikin Applied OEM Parts


Are What Your HVAC Unit Needs!

McQuay Global Air-Cooled Reciprocating Chiller


AGR
055-100 Vintage A
Critical Components
Control
Control, Speedtrol (P66)
Transducer, Pressure 1-150 PSI
UNT Control Panel
Main Controller UNT
Switch, Presssure 100-425 PSI
Switch, Presssure 170-290 PSI
Switch, Presssure 300-375 PSI
MicroTech Control Panel
ADI Board
Output Board
MicroTech Controller M250
Keypad Display
Ribbon Cable, 50 Conductor 48"
Ribbon Cable, 26 Conductor 72"
Compressor
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step, 6 Step
CMPR #1, 4 Step, 6 Step
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step, 6 Step
CMPR #1, 4 Step, 6 Step

UNIT SIZE

Voltage

Part Number

All
All

All
All

048445202
065816801

All
All
All
All

All
All
All
All

074804901
074805301
073074003
073074005

All
All
All
All
All
All

All
All
All
All
All
All

065816001
049265501
065487306
065497201
049265201
065499704

055-060
055-060
065-070
065-070
065-070
065-070
075-080
075-080
075-080
075-080
085-095
100
055-060
055-060
065-070
065-070
075-080
075-080
085-095
100

208-230/60/3
208-230/60/3
208/60/3
208/60/3
230/60/3
230/60/3
208/60/3
208/60/3
230/60/3
230/60/3
208-230/60/3
208-230/60/3
460/60/3
460/60/3
460/60/3
460/60/3
460/60/3
460/60/3
460/60/3
460/60/3

071846201
071838301
071846701
071846801
071835401
071836801
071835901
071838001
071835701
071837601
074554901
074556901
071846101
071838401
071835501
071836901
071835801
071837701
074555101
074557101

Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.
To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS
571180 Rev. R 07/2015

CPL Page 1 of 3

Critical Daikin Applied OEM Parts


Are What Your HVAC Unit Needs!

McQuay Global Air-Cooled Reciprocating Chiller


AGR
055-100 Vintage A

Critical Components
Compressor, continued
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step
CMPR #1, 6 Step
CMPR #1, 4 Step, 6 Step
CMPR #1, 4 Step, 6 Step
CMPR #1, 4 Step, 6 Step
CMPR #2, 4 Step
CMPR #2, 4 Step
CMPR #2, 4 Step
CMPR #2, 6 Step
CMPR #2, 6 Step
CMPR #2, 6 Step
CMPR #2, 4 Step
CMPR #2, 6 Step
CMPR #2, 4 Step
CMPR #2, 6 Step
CMPR #2, 4 Step, 6 Step
CMPR #2, 4 Step, 6 Step
CMPR #2, 4 Step
CMPR #2, 6 Step
CMPR #2, 4 Step
CMPR #2, 6 Step
CMPR #2, 4 Step
CMPR #2, 6 Step
CMPR #2, 4 Step, 6 Step
CMPR #2, 4 Step, 6 Step
CMPR #2, 4 Step
CMPR #2, 6 Step
CMPR #2, 4 Step
CMPR #2, 6 Step
CMPR #2, 4 Step, 6 Step
CMPR #2, 4 Step, 6 Step
CMPR #2, 4 Step, 6 Step

UNIT SIZE

Voltage

Part Number

055-060
055-060
065-070
065-070
075-080
085-095
100
055
060-065
060-065
055
060-065
060-065
070-075
070-075
070-075
070-075
080-090
095-100
055
055
060-065
060-065
070-075
070-075
080-090
095-100
055
055
060-065
060-065
070-075
080-090
095-100

575/60/3
575/60/3
575/60/3
575/60/3
575/60/3
575/60/3
575/60/3
208-230/60/3
208/60/3
230/60/3
208-230/60/3
208/60/3
230/60/3
208/60/3
208/60/3
230/60/3
230/60/3
208-230/60/3
208-230/60/3
460/60/3
460/60/3
460/60/3
460/60/3
460/60/3
460/60/3
460/60/3
460/60/3
575/60/3
575/60/3
575/60/3
575/60/3
575/60/3
575/60/3
575/60/3

071846601
071838501
071835601
071837001
071837801
074555501
074557501
071846201
071846701
071835401
071838301
071846801
071836801
071835901
071838001
071835701
071837601
074554901
074556901
071846101
071838401
071835501
071836901
071835801
071837701
074555101
074557101
071846601
071838501
071835601
071837001
071837801
074555501
074557501

Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.
To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS
571180 Rev. R 07/2015

CPL Page 2 of 3

Critical Daikin Applied OEM Parts


Are What Your HVAC Unit Needs!

McQuay Global Air-Cooled Reciprocating Chiller


AGR
055-100 Vintage A

Critical Components
Sensor
Evaporator Leaving Water Temp, 30FT
Evaporator Entering Water Temp, 10FT
Pressure Transducer Low
Pressure Transducer High
TSTAT (PC12, PC22)
TSTAT (TC11)
Temperature Sensor
Fan Motor and Components
Fan Prop, 28" X 3.92-3.00" Blade
Fan Prop, 28" X 4.45-3.52" Blade
Fan Prop, 28" X 3.53-2.40" Blade Speedtrol
Motor, 1.5HP
Motor, 1.5HP TE
Motor, 1.0HP Speedtrol
Motor, 2.0HP TE

UNIT SIZE

Voltage

Part Number

ALL
ALL
ALL
ALL
ALL
ALL
ALL

ALL
ALL
ALL
ALL
ALL
ALL
ALL

073012003
073012001
065816801
065816802
074805201
074805101
330386401

055-065
070-100
055-100
055-065
055-065
055-100
070-100

ALL
ALL
ALL
208-230/460/60/3
208-230/460/60/3
208-230/460/60/1
208-230/460/60/3

072941302
073061401
072972201
072937601
073000501
070989600
073018701

Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.
To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS
571180 Rev. R 07/2015