Você está na página 1de 252

Product Guide

Roadway

Edition Three
Decorative

Security

Area

Flood

Controls

Poles

The AEL Advantage


For more than 50 years, American Electric Lighting (an Acuity Brands Company) has produced the highest
quality outdoor, utility, and infrastructure lighting products. Continuing in our tradition of excellence, Edition
Three of the AEL Product Guide offers a complete package of products for these applications, including
Roadway, Decorative, Area, Security, and Floodlighting luminaires, as well as Poles and Photocontrols.
However the real AEL Advantage extends beyond our product breadthits the quality and innovation in
our productsits our knowledgeable sales, service and support teams and its the reliability of our
delivery and product performance. Read on for more about the AEL Advantage.

Nighttime FriendlyTM
In response to the increased demand for products that reduce light pollution, Acuity Brands Lighting
established the Nighttime Friendly designation to recognize products across our brands that
minimize light pollution. Nighttime Friendly products provide superior optical control consistent with
the goals of USGBC LEED and Green Globes product criteria for light pollution reduction. Products
marked as Nighttime Friendly must meet stringent photometric requirementsat a minimum, these products are full
cutoff and emit no more than 10% of their total lumens above 80 degrees from nadir. Look for the Nighttime Friendly
logo throughout this edition of the AEL catalog.

Preferred Selection Catalog Numbers


Not sure what to order? These numbers (visible throughout the catalog) represent our most popular product
configurationsmany are available for immediate shipment. Look to these numbers for a quick-reference ordering guide.

Utility-Friendly Features
AEL products are designed with several utility-friendly features in mind, such as tool-less entry, tool-less adjustable
photocontrol receptacles, terminal blocks, breathing seal gaskets, interchangeable optics, and wildlife shields.
Check individual product pages for more details, or visit us at www.americanelectriclighting.com to view our
Specification Sheets.

Dark-to-Light (DTL) Photocontrols


The AEL product offering includes Dark-to-Light Photocontrols, the leader in electronic
photocontrol technology. DTL controls are available in combination with AEL products (where
noted) or in stand-alone configurations.

Dedicated Sales and Service


Our products are marketed through a combination of sales agents and a dedicated factory sales force that targets
utilities, municipalities and specifiers. Each of our sales representatives (many of whom are Lighting Certified) has
intimate knowledge of their particular market, as well as our products. Our outstanding Customer Service and Tech
Support teams are equally knowledgeable and friendly, and more importantly, never outsourced.

Industry-Leading Warranty
AEL was the first to offer a 6-year warranty on luminaire electrical components* across our entire product line and
remains the industry leader on product warranties. How are we able to offer longer coverage than the competition?
Put simply, we build products that perform reliably, and we stand behind the products we build.
* See Terms & Conditions for full warranty information.

American
Electric
Lighting
Product Guide
Edition Three
We are pleased to present the third edition of the American Electric Lighting (AEL) and Dark to Light (DTL) product guide. AEL is a
company on the move in the public infrastructure and utility lighting market, with products that have been successful for over 55
years in roadway, security, area, flood and decorative outdoor lighting. DTL has been a large part of that success by offering topof-the-line photocontrols. Our goal is to continue to provide the superior design, quality and reliability that our customers demand.
On each product page, AEL has identified a selection of products designated as Preferred Selection. Products shown as
Preferred Selection catalog numbers are frequently ordered, standard products that will be quickly shipped to satisfy your
application requirements. Included in each section are ballast and optical matrices for each product. Use them to help
determine the best ballast and optical configurations for your needs. Also, a selection guide has been added to the DTL pages to
help you choose the best photocontrols for your application.
For the most up-to-date product information, photometric files, specification sheets and other technical data that AEL and DTL
have to offer, visit our website, www.americanelectriclighting.com.
We at American Electric Lighting are confident this catalog will be a useful tool for you. We look forward to working with you to
satisfy your lighting requirements. Thank you for your continued support.
Sincerely,
The AEL Team

AEL Preferred Selection Program

Preferred Selection Program

AEL products are offered with an extensive list of source, ballast,


optical and option choices for customers with specific
application requirements. For most applications a listing
of Preferred Selection catalog numbers is provided for
each product. These products are frequently
ordered and can be shipped in as little as 1
week in many cases. Consult with your AEL
sales representative for actual lead time.

For more information, contact


Customer Service at:

1-800-754-0463

American Electric Lighting


Roadway Lighting
TA B L E O F C O N T E N T S
ROADWAY LIGHTING
Product Overview ...............................10
Ordering Information ..........................11

Roadway Cobrahead Series 125


Product Overview ...............................26
Ordering Information ..........................27

Product Overview ...............................12


Ordering Information ..........................13

Roadway Cutoff Cobrahead Series 125


Product Overview ...............................28
Ordering Information ..........................29

DuraStar Roadway Lighting System Series 20


Product Overview ...............................14
Ordering Information ..........................15

Roadway Cobrahead Series 325


Product Overview ...............................30
Ordering Information ..........................31

DuraStar Roadway Lighting System Series 30


Product Overview ...............................16
Ordering Information ..........................17

Roadway Cutoff Cobrahead Series 325


Product Overview ...............................32
Ordering Information ..........................33

Roadway Cobrahead Series 115


Product Overview ...............................18
Ordering Information ..........................19

Roadway Cobrahead Series 327


Product Overview ...............................34
Ordering Information ..........................35

Roadway Cutoff Cobrahead Series 115


Product Overview ...............................20
Ordering Information ..........................21

Multi-Mount Series 285


Product Overview ...............................36
Ordering Information ..........................37

Roadway Cobrahead Series 315


Product Overview ...............................22
Ordering Information ..........................23

InterState II Luminaire Series 775


Product Overview ...............................38
Ordering Information ..........................39

Roadway Cutoff Cobrahead Series 315


Product Overview ...............................24
Ordering Information ..........................25

LPS Roadway/Area Luminaire Series SRX


Product Overview ...............................40
Ordering Information ..........................41

CVM

CVL

Product Guide

American Electric Lighting


Roadway Lighting, Decorative Post Top Lighting
TA B L E

LPS Roadway/Area Luminaire Series SP2


Product Overview ...............................42
Ordering Information ..........................43

Georgian Series

Underpass Series 581/681


Product Overview ...............................44
Ordering Information ..........................45

Bainbridge Series

Wallpack Series 882


Product Overview ...............................46
Ordering Information ..........................47

Marietta Series

SignLite Series 875


Product Overview ...............................48
Ordering Information ..........................49

Sumter Series

Accessories..........................................................................50

Cresthill Classic

O F

C O N T E N T S

Product Overview................................66
Ordering Information ..........................67

Product Overview................................68
Ordering Information ..........................69

Product Overview................................70
Ordering Information ..........................71

Product Overview................................72
Ordering Information ..........................73

Product Overview................................74
Ordering Information ..........................75

Ballast Matrices ..................................................................52

DECORATIVE AND POST-TOP LIGHTING


Cresthill Sphere
Product Overview................................76
Ordering Information ..........................77

Valiant
Product Overview ...............................60
Ordering Information ..........................61

American Revolution Deluxe Series


Product Overview ...............................62
Ordering Information ..........................63

Cresthill Centennial
Product Overview................................78
Ordering Information ..........................79

Cresthill Glass
American Revolution Series 247
Product Overview................................64
Ordering Information ..........................65

Product Overview................................80
Ordering Information ..........................81

Product Guide

American Electric Lighting


Decorative Post Top Lighting, Security Lighting, Area Lighting
TA B L E

O F

C O N T E N T S
SECURITY LIGHTING

Lexington
Product Overview................................82
Ordering Information ..........................83

NEMA Head Series 11


Product Overview..........................108
Ordering Information.....................109

Product Overview................................84
Ordering Information ..........................85

NEMA Head Package Series 11 PKG


Product Overview..........................110
Ordering Information.....................111

Contemporary Series 245


Product Overview................................86
Ordering Information ..........................87

Series 11 L Package
Product Overview..........................112
Ordering Information.....................113

TwistPack Series TWT


Product Overview................................88
Ordering Information ..........................89

Dusk to Dawn Series DTD


Product Overview..............................114
Ordering Information ........................115

Branson

Series 165

Decorative Poles

Product Overview..............................116
Ordering Information ........................117

Chadsworth Series
Product Overview................................90
Ordering Information ..........................91
New Albany Series
Product Overview................................92
Ordering Information ..........................93
Statesboro Series
Product Overview................................94
Ordering Information ..........................95

Accessories .......................................................................118
Ballast Matrices ................................................................119

AREA LIGHTING
ASA
Product Overview..............................122
Ordering Information ........................123

Waycross Series
Product Overview................................96
Ordering Information ..........................97
Weatherproof Receptacles .............................................98
Ballast Matrices ..............................................................100

Product Guide

PES
Product Overview..............................124
Ordering Information ........................125

American Electric Lighting


Area Lighting, Floodlighting
TA B L E

PEM
Product Overview..............................126
Ordering Information ........................127

O F

C O N T E N T S

LuxMaster Classic Series LM


Product Overview..............................142
Ordering Information ........................143

Accessories.......................................................................144

VMR
Product Overview..............................128
Ordering Information ........................129

Ballast Matrices ...............................................................148

FLOODLIGHTING
ACP Series

VLR
Product Overview..............................130
Ordering Information ........................131

Product Overview..............................154
Ordering Information ........................155

Product Overview..............................132
Ordering Information ........................133

UltraFloodTM Series 75
Product Overview..............................156
Ordering Information ........................157

Product Overview..............................134
Ordering Information ........................135

UltraFloodTM Series 77
Product Overview..............................158
Ordering Information ........................159

LuxMaster Luminaire 53
Product Overview..............................136
Ordering Information ........................137

Energy Saver Series CES


Product Overview..............................160
Ordering Information ........................161

LuxMaster Luminaire 153


Product Overview..............................138
Ordering Information ........................139

Quartz Flood Series 570


Product Overview..............................162
Ordering Information ........................162

LuxMaster Classic Series LS


Product Overview..............................140
Ordering Information ........................141

Quartz Flood Series 474


Product Overview..............................163
Ordering Information ........................163

AVL-BIA

AVL

Product Guide

American Electric Lighting


Floodlighting, Photocontrols
TA B L E

O F

C O N T E N T S

AmeriSport Series ASP


Product Overview .............................164
Ordering Information ........................165

D7790 Series

Sportslighting Series SPF


Product Overview .............................166
Ordering Information ........................167

DD Series Diagnostic
Product Overview .............................182
Ordering Information ........................182

Accessories.......................................................................168

DPN Series Part Night


Product Overview .............................183
Ordering Information ........................183

Ballast Matrices ...............................................................173

Product Overview .............................181


Ordering Information ........................181

ELECTRONIC PHOTOCONTROLS
DP Series Silicon

DBE Series Button


Product Overview .............................176
Ordering Information ........................176

Product Overview .............................184


Ordering Information ........................184

DE Series Filtered Silicon


Product Overview .............................177
Ordering Information ........................177

Shorting and Open Caps


Product Overview .............................185
Ordering Information ........................185

DP 1704 Utility Premium


Product Overview .............................178
Ordering Information ........................178

Accessories ........................................................................186
Recommendation Chart ......................................................186
ANSI Color Chart..................................................................186

DX Series Basic
Product Overview .............................179
Ordering Information ........................179

DUX Series Basic


Product Overview .............................180
Ordering Information ........................180

Product Guide

American Electric Lighting


Poles, Options & Accessories
TA B L E

POLES

O F

C O N T E N T S

TECHNICAL DATA

Illustrated Samples .........................................................188

HPS Replacement Starters............................................232

Wind Map .........................................................................189

Lamp Selection ................................................................233

Florida Wind Rating ........................................................190

Fuse Ratings.....................................................................234

General Information........................................................191

Luminaire Classification Systems. ...............................240

RSA ...................................................................................192

Floodlighting Applications. ............................................241

RTA ...................................................................................193

Floodlight Calculations...................................................242

RSAH .................................................................................194

Roadway Lighting Application Design.........................243

SSA ...................................................................................195

Terms & Conditions.........................................................244

SSAH .................................................................................196

Index..................................................................................246

RSS ...................................................................................197
RTS ...................................................................................198
SSS ...................................................................................199
STS ...................................................................................200
STSH..................................................................................201
Pole Options .....................................................................202
Aluminum Mounting Brackets ......................................203
Steel Mounting Brackets...............................................204
RTF ...................................................................................205
RTFDB ...............................................................................206
SSF ...................................................................................207
STC ...................................................................................208
SPRTC ...............................................................................209
SPRTS ...............................................................................213
RTAU..................................................................................216
RTSU..................................................................................220
AMAW / SMAW...............................................................222
AMAC / SMAC .................................................................224
SMAWL.............................................................................226
Traditional Wood Pole Arms..........................................228
Traditional Concrete Pole Arms....................................229

Product Guide

NOTES

Product Guide

ROADWAY LIGHTING
Corvus CVM Series ..............................................10
Corvus CVL Series ................................................12
DuraStar Series 20 ................................................14
DuraStar Series 30 ................................................16
Roadway 115 ............................................................18
Roadway 115 Cutoff .................................................20
Roadway 315 ............................................................22
Roadway 315 Cutoff .................................................24
Roadway 125 ............................................................26
Roadway 125 Cutoff .................................................28
Roadway 325 ............................................................30
Roadway 325 Cutoff .................................................32
Roadway 327 .............................................................34
Multi-Mount 285.....................................................36
InterState II 775 ....................................................38
LPS Roadway - SRX .................................................40
LPS Roadway - SP2..................................................42
Underpass 581/681 ...................................................44
Heavy-Duty Wallpack 882.......................................46
SignLite 875 ...............................................................48
Accessories ..............................................................50
Ballast Matrices .......................................................52

American Electric Lighting


9

Corvus Series CVM


Roadway Lighting
70-250W HPS, 70-250W MH

P R O D U C T

O V E R V I E W

Features:

NEW

The contemporary style of the CorvusTM CVM combines superior mechanical


construction, a choice of light distributions, lamp types, and mounting options
to make it a truly flexible luminaire for a variety of applications
Die-cast aluminum body has direct access to the lamp and electrical
components from the top
Universal mounting system can be secured on a 2-3/8" to 3" O.D. vertical tenon,
or on a 1-7/8 to 2-3/8 O.D. horizontal arm
Using a single door entry and a standard hood support brace; full access to
fixture interior including electrical gear and the optical chamber is
straighforward, reducing maintenance time
Tool-less lamp access and a removable power pad with quick disconnects
allow for ease of gear and lamp replacement
Hydroformed anodized aluminum reflector is enclosed by tempered shock
resistant curved glass. The luminaire is sealed with a silicone gasket.
Photocontrol receptacle is adjustable without tools reducing installation time

Applications:

Ambient rated 40C outdoor

City streetscapes
Residential streets
City streets
Parking lots
Campuses

Optical chamber is IP66 rated standard, gear compartment is IP44 rated


All electrical components warranted by American Electric Lighting's 6-year
guarantee

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

CVM 10S RN 120 R2


CVM 10S CA MT1 R2
CVM 17M SC MT1 R2
CVM 25M SC MT1 R3

Effective Projected Area (EPA)


The EPA for the Corvus Medium is .74 sq. ft.
Approx. Wt. = 34 lbs.

10

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Corvus Series CVM


Roadway Lighting
70-250W HPS, 70-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: C V M 1 0 S C A M T 1 R 2

Wattage / Source

Series
CVM Corvus Medium
Architectural
Cobrahead

07 70W
10 100W
13 100/150W
Wired 100W
14 100W
Wired 150W
15 150W
17 175W
20 200W
25 250W

Voltage

Distribution

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V

R2 Roadway Type II
R3 Roadway Type III

Ballast

S HPS
M MH

Refer to the ballast matrix on


page 52 for compatibility.

RN

Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)1

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Refer to optic distribution


matrix below for compatibility.

Options
Paint
(blank)
BK
BZ
WH

Gray (standard)
Black
Bronze
White

Terminal Block2
(blank) Terminal Block (standard)
T2
Wired to L1 to L2 Position
T3
3 Wire Operation
(L1, N, L2 Position)
Fusing3
SF
Single Fuse (120, 277, 347V)
DF
Double Fuse (208, 230, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR
No Photocontrol Receptacle4

Lamp
LC
LD
Misc.
BL
PC
SS
LA
5H
NN
SH
SC2

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Bubble Level
Photocontrol Included per
Voltage Specified4
Stainless Steel Fasteners
Lightning Arrestor
50 Hertz Ballast Cycle5
No NEMA Label on Housing
Shorting Cap4
Cutoff optics for R2 Distribution Only

Notes:
1 150W maximum
2 T3 option only available with 240, 480, DT2, DT4, MT2
3 Not available in MT, TT, DT voltages
4 PC and SH not available with NR
5 Limited availability, consult factory

Optic Distribution
07S
10S
10M
15S
17M
25S
25M

R2
N
N
N
N
N
N
N

R3
N
N
N
N
N
N
N

R2 SC2
N
N
N
N
N
N
N

Product Guide

11

Corvus Series CVL


Roadway Lighting
100-400W HPS, 100-400W MH

P R O D U C T

O V E R V I E W

Features:

NEW

The contemporary style of the CorvusTM CVL combines superior mechanical


construction, a choice of light distributions, lamp types, and mounting options
to make it a truly flexible luminaire for a variety of applications
Die-cast aluminum body with access to the lamp from the bottom, and a gear
access canopy made of precision die-cast aluminum on the top
The tool-less top-entry captive hood allows for full access to the removable
electrical power pad, with quick disconnects for user-friendly gear
replacement
Separate tool-less optical chamber access reduces time spent during lamp
exchange
Universal mounting system can be secured on a 2-3/8" vertical tenon, or on a
1-5/8 to 2-3/8 O.D. horizontal arm
Hydroformed anodized aluminum reflector is enclosed by tempered shock
resistant curved glass. The luminaire is sealed with a silicone gasket.
Photocontrol receptacle is adjustable without tools reducing installation time

Applications:

Optical chamber is IP66 rated standard, gear compartment is IP44 rated

Roadways
Residential streets
City streets
Parking lots
Campuses

Ambient rated 40C outdoor, except for Mag Reg.


All electrical components warranted by American Electric Lighting's 6-year
guarantee

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

CVL 25M SC MT1 R3


CVL 40M SC MT1 R3
CVL 25S CA MT1 R3
CVL 40S CA MT1 R3

Effective Projected Area (EPA)


The EPA for the Corvus Large is 1.03 sq. ft.
Approx. Wt. = 43 lbs.

12

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Corvus Series CVL


Roadway Lighting
100-400W HPS, 100-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: C V L 4 0 S C A M T 1 R 3

Wattage / Source

Series
CVL Corvus Large
Architectural
Cobrahead

Voltage

Distribution

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V

R2 Roadway Type II
R3 Roadway Type III

Ballast

10 100W
S HPS
13 100/150W
M MH
Wired 100W
14 100W
Wired 150W
15 150W
17 175W
20 200W
25 250W
23 250/400W
Wired 250W
24 250/400W
Wired 400W
31 310W
40 400W
Refer to the ballast matrix on
page 52 for compatibility.

RN

Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Refer to optic distribution


matrix below for compatibility.

Options
Mounting
(blank) Mast Arm (standard)
TT
Tenon Top
Paint
(blank)
BK
BZ
WH

Gray (standard)
Black
Bronze
White

Terminal Block1
(blank) Terminal Block (standard)
T2
Wired to L1 to L2 Position
T3
3 Wire Operation
(L1, N, L2 Position)
Listing
UL
UL Listed
CS
CSA Certified
MX
NOM Listed
Fusing2
SF
Single Fuse (120, 277, 347V)
DF
Double Fuse (208, 230, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR
No Photocontrol Receptacle4
Lamp
LC
LD
Misc.
5H
BL
PC
SS
LA
NN
SH

Notes:
1 T3 option only available with 240, 480, DT2, DT4, MT2
2 Not available in MT, TT, DT voltages
3 Limited availability - consult factory
4 PC and SH not available with NR

Lamp Included, Clear


Lamp Included, Deluxe/Coated

50 Hertz Ballast Cycle3


Bubble Level
Photocontrol Included per
Voltage Specified4
Stainless Steel Fasteners
Lightning Arrestor
No NEMA Label on Housing
Shorting Cap4

Optic Distribution
17M
25S
25M
31S
40S
40M

R1
N
N
N

R2
N
N
N
N
N
N

R3
N
N
N

Product Guide

13

DuraStar Series 20
Roadway Lighting
50-150W HPS, 175W MH

P R O D U C T

O V E R V I E W

Features:
Revolutionary DuraLock docking system provides modular installation and
interchangeability for easy maintenance. Rugged die-cast, powder-coated
docking station mounts securely to mast-arm to ensure secure wiring and
long-lasting stability. Durable lightweight lighting fixture positively docks by
plugging in with a 20 locking twist
High-efficiency optical system maximizes light output while minimizing glare
Starter component is externally accessible for easy maintenance and is fully
encapsulated for long life
Wildlife shield is cast into the docking station (not a separate piece) and is
easily adjustable for 1-1/4" to 2" (1-5/8 to 2-3/8 O.D.) mast arms
Cam-latch doorframe allows easy re-lamping without tools
Large surface area "breathing seal" gasket, seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture
Photocontrol receptacle is adjustable without tools

Applications:
Roadways
Residential areas
Coastal areas salt/corrosive environments
Parking lots
Storage areas

All electrical components warranted by American Electric Lighting's 6-year


guarantee
E39 mogul base socket standard
Suitable for -30C MH / -40C HPS
Optical chamber is IP64 rated standard
Complies with ANSI: C136.2, C136.10, C136.15, C136.31

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

20 10S RN 120 R2 FG
20 10S RN 120 R3 FG
20 15S RN 120 R2 FG
Horizontal Arm Mount

Vertical Tenon Mount

Effective Projected Area (EPA)


The EPA for the DuraStar is .56 sq. ft.
The EPA for the DuraStar sag lens, is .70 sq. ft.
Approx. Wt. = 14 lbs.

14

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

DuraStar Series 20
Roadway Lighting
50-150W HPS, 175W MH

O R D E R I N G

I N F O R M AT I O N

Example: 2 0 1 0 S R N 1 2 0 R 3 F G L C P C

Wattage / Source

Series
20 DuraStar
Cobrahead

05
07
10
15
17

50W
70W
100W
150W
175W

S HPS
M MH3

RN
RH
XN

Refer to the ballast matrix on


page 52 for compatibility.

Voltage

Ballast

XH

CA
CT

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance
(Lag) Normal
Power Factor
High Reactance
(Lag) High
Power Factor
CWA
CWI

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Distribution

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V

R2 Roadway Type II
R3 Roadway Type III

Refer to optic distribution


matrix below for compatibility.
Optics
SA Sag Acrylic Lens
SP Sag Polycarbonate Lens
FG Flat Glass Clear Tempered4

Options
Mounting
(blank) Duralock Docking Station Set
for 1-1/4 Mast Arm
M2
2-bolt Internal 2 Setting, for
Duralock Docking Station
for 2 Mast Arm
ML
Less Duralock Docking Station
VT
Vertical Tenon Docking Station

Misc.
PC
PK

SS
PL

Paint
(blank)

Gray (standard)

Listing
UL
CS

UL Listed
CSA Certified

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
NR
No Photocontrol Receptacle1
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

5H
SH
LCU

Photocontrol Included per


Voltage Specified1
Package (includes lamp,
photocontrol, 5 supply-wire,
mast arm, hardware)
Stainless Steel Fasteners
(external)
Distribution Pattern
Indicator Label
50 Hertz Ballast Cycle2
Shorting Cap1
Low Copper Alloy Content
Docking Station (less than 1%)

Notes:
1 PC, SH not available with NR option
2 Limited availability, please contact your local
American Electric Lighting representative
3 175W MH available standard, other wattages please
contact your local American Electric Lighting
representative
4 Nighttime FriendlyTM optic

Optic Distribution
05S
07S
10S
15S
17M

R2SA
N
N
N
N
-

R3SA R2SP
N
N
N
N
N
N
N
N
N

R3SP
N
N
N
N
N

R2FG
N
N
N
N
-

R3FG
N
N
N
N
-

Product Guide

15

DuraStar Series 30
Roadway Lighting
200-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
Revolutionary DuraLock docking system provides modular installation and
interchangeability for easy maintenance. Rugged die-cast, powder-coated
docking station mounts securely to mast-arm to ensure secure wiring and
long-lasting stability. Durable lightweight lighting fixture positively docks by
plugging in with a 20 locking twist
High-efficiency optical system maximizes light output while minimizing
objectionable glare
Starter component is externally accessible for easy maintenance and is fully
encapsulated for long life
Wildlife shield is cast into the docking station (not a separate piece) and is
easily adjustable for 1-1/4" to 2" (1-5/8 to 2-3/8 O.D.) mast arms
Die-cast trigger latch on door frame enables easy and secure one-hand
opening for re-lamping and maintenance
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture

Applications:

Photocontrol receptacle is adjustable without tools

Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

All electrical components warranted by American Electric Lighting's 6-year


guarantee
E39 mogul base socket standard
Suitable for -30C MH / -40C HPS
Optical chamber is IP64 rated standard
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
DIMENSIONS
PREFERRED SELECTION CATALOG NUMBERS

30 25S CA MT1 R2 FG
30 40S CA MT1 R3 FG

Horizontal Arm Mount

Vertical Tenon Mount

Effective Projected Area (EPA)


The EPA for the DuraStar Series 30 is 1.24 sq. ft. flat glass
The EPA for the DuraStar Series 30 is 1.43 sq. ft. sag glass
Approx. Wt. = 30 lbs.

16

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

DuraStar Series 30
Roadway Lighting
200-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 3 0 2 5 S C A M T 1 R 3 F G L C P C

Wattage / Source

Series
30 DuraStar
Cobrahead

17
20
25
31
40
23

175W
200W
250W
310W
400W
250/400W
Wired 250W1
24 250/400W
Wired 400W1

S HPS
M MH

Refer to the ballast matrix on


page 53 for compatibility.

Voltage

Ballast
RN

Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap wired 480V2

Distribution
R2 Roadway Type II
R3 Roadway Type III

Refer to optic distribution


matrix below for compatibility.
Optics
SG Sag Glass Clear Tempered
FG Flat Glass Clear Tempered6

Options
Mounting
(blank) Duralock Docking Station Set
for 1-1/4 Mast Arm
M2
2-bolt Internal 2 Setting, for
Duralock Docking Station
ML
Less Duralock Docking Station
VT
Vertical Tenon Docking Station
Color
(blank)
Listing
UL
CS

Misc.
PC
SS

Gray (standard)
PK
PL
UL Listed
CSA Certified

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
NR
No Photocontrol Receptacle3
Lamp
LC
LD

Starter4
(blank) Externally Mounted Encapsulated
Plug-In
OB Open Board Internal

Lamp Included, Clear


Lamp Included, Deluxe/Coated

5H
SH
LCU

Photocontrol Included per


Voltage Specified3
Stainless Steel Fasteners
(external)
Includes Lamp, LC, PC, Arm
Distribution Pattern
Indicator Label
50 Hertz Ballast Cycle5
Shorting Cap3
Low Copper Alloy Content
Docking station (less than 1%)

Notes:
1 Not available in 5-tap
2 250W and 400W only
3 PC, SH not available with NR option
4 Available in HPS only
5 Limited availability, please contact your local
American Electric Lighting representative
6 Nighttime FriendlyTM optic

Optic Distribution
20S
25S
31S
40S
17M
25M
40M

R2SG R3SG R2FG R3FG


N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Product Guide

17

Roadway Series 115


Roadway Lighting
35-400W HPS, 175-250W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (1-5/8 to 2-3/8 O.D.) diameter. Optional four-bolt
mounting provides extra security in high-vibration applications
Die-cast trigger latch on doorframe enables easy and secure one-hand
opening for re-lamping and maintenance
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) on the two-bolt
unit and is easily adjustable for 1-1/4" to 2" (1-5/8 to 2-3/8 O.D.) mast arms
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution with
borosilicate glass, acrylic, or polycarbonate refractor

Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard
All electrical components warranted by American Electric Lighting's 6-year
guarantee
E39 mogul base socket standard
Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31

DIMENSIONS
27"
(686)

PREFERRED SELECTION CATALOG NUMBERS

115 10S RN 120 R2 DA


115 15S CA MT1 R2 DA EC
115 15S RH 120 R2 DA
115 25S CA MT1 R3 DG EC

10.1"
(257)

10.1"
(257)

13"
(330)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 115 is 0.9 sq. ft.
Approx. Wt. = 19 lbs.

18

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 115


Roadway Lighting
35-400W HPS, 175-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: 1 1 5 1 5 S R N 1 2 0 R 2 D G L C P C

Series
115 Single Door
Cobrahead

Ballast

Wattage / Source
03
05
07
10
13
14
15
17
20
25
40

35W
50W
70W
100W
100/150W
Wired 100W
100/150W
Wired 150W
150W
175W
200W
250W
400W1

S
M

HPS
MH

Refer to the ballast matrix on


page 53 for compatibility.

RN

Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

Distribution

Voltage
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT3
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 208V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V

R2
R3
RX

Roadway Type II
Roadway Type III
Roadway Type II
4-way3

Refer to optic distribution


matrix below for compatibility.
Optics
DA
DP
DG

Drop Acrylic
Prismatic Refractor
Drop Polycarbonate
Prismatic Refractor
Drop Glass
Prismatic Refractor

Options
Mounting
(blank) 2-bolt Internal
EF
External Fitter (2-bolt only)
4B
4-bolt Internal
M2
2-bolt Internal 2 Setting
E2
External Fitter 2 Mast Arm
(2-bolt only)
Paint4
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2
Wired to L1 to L2 Position
T3
3 Wire Operation
(L1, N, L2 Position)5
Listing
UL
CS

UL Listed
CSA Certified

Fusing6
SF
Single Fuse (120, 277, 347V)
DF
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR
No Photocontrol Receptacle7

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter1
(blank) Open Board (standard)
EC
Encapsulated Plug-in
OP
Open Plug-in
Misc.
PC
BL
SS
CF
PL
LA
5H
SH
HK
BF
RG

Photocontrol Included per


Voltage Specified7
Bubble Level
Stainless Steel Fasteners
(external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle2
Shorting Cap7
Hinge Keeper
3G Vibration8
Rubber Silicone Optical Gasket

Notes:
1 For HPS products only
2 Limited availability, please contact your local
American Electric Lighting representative
3 DG option only
4 Other colors available, please contact your local
American Electric Lighting representative
5 T3 option only available with 240, 480, DT2, DT4, MT2
6 Not available in MT, TT, DT voltages
7 SH, and PC not available with NR option
8 Tested to withstand 3G vibration, 4B option required

Optic Distribution
03S
05S
07S
10S
15S
20S
25S
40S
17M
25M

R2DA R3DA R2DP R3DP R2DG R3DG RXDG


N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Product Guide

19

Roadway Series 115


Roadway Lighting Cutoff Style
35-250W HPS, 175-250W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (1-5/8 to 2-3/8 O.D.) diameter. Optional four-bolt
mounting provides extra security in high-vibration applications
Die-cast trigger latch on doorframe enables easy and secure one-hand
opening for re-lamping and maintenance
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) on the two-bolt
unit and is easily adjustable for 1-1/4" to 2" (1-5/8 to 2-3/8 O.D.) mast arms.
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution with either
flat or sag clear tempered glass

Applications:

NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard

Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

All electrical components warranted by American Electric Lighting's 6-year


guarantee
E39 mogul base socket standard
Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31
DIMENSIONS
PREFERRED SELECTION CATALOG NUMBERS

115 10S CA MT1 R2 FG EC


27"
(686)
6-1/2"
(165)

13"
(330)
6-1/2"
(165)

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire Series 115 with cutoff is .74 sq. ft.
Approx. Wt. = 19 lbs.

20

Product Guide

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire Series 115 with sag glass is .82 sq. ft.

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 115


Roadway Lighting Cutoff Style
35-250W HPS, 175-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: 1 1 5 1 5 S C A M T 1 R 3 F G L C P C H P

Wattage / Source

Series
115 Single Door
Cobrahead

03
05
07
10
13
14
15
17
20
25

35W
50W
70W
100W
100/150W
Wired 100W
100/150W
Wired 150W
150W
175W
200W
250W

S
M

HPS
MH

Refer to the ballast matrix on


page 53 for compatibility.

Voltage

Ballast
RN

Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)

Distribution

R2 Roadway Type II
120V
R3 Roadway Type III
208V
240V
Refer to optic distribution
277V
matrix below for compatibility.
347V
480V
Multi-tap Wired 120V
Optics
Multi-tap Wired 240V
Multi-tap Wired 277V
FG Flat Glass Clear Tempered9
Tri-tap Wired 347V
SG Sag Glass Clear Tempered
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V
120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Options
Mounting
(blank) 2-bolt Internal
EF
External Fitter (2-bolt only)
4B
4-bolt Internal
M2
2-bolt Internal 2 Setting
E2
External Fitter 2 Mast Arm
(2-bolt only)
Paint2
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2
Wired to L1 & L2 Positions
T3
3 Wire Operation
(L1, N, L2 Position)3
Listing
UL
CS

UL Listed
CSA Certified

Fusing4
SF
Single Fuse (120, 277, 347V)
DF
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR
No Photocontrol Receptacle5

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter6
(blank) Open Board (standard)
EC
Encapsulated Plug-in
OP
Open Plug-in
Misc.
PC
BL
SS
CF
PL
LA
5H
SH
HK
HP
BF
RG

Photocontrol Included per


Voltage Specified5
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle1
Shorting Cap5
Hinge Keeper
High Performance7
3G Vibration8
Rubber Silicone Optical Gasket

Notes:
1 Limited availability, please contact your local
American Electric Lighting representative
2 Other colors available, please contact your local
American Electric Lighting representative
3 T3 option only available with 240, 480, DT2, DT4, MT2
4 Not available in MT, TT, DT voltages
5 PC and SH not available with NR option
6 For HPS products only
7 FG optics only
8 Tested to withstand 3G vibration, 4B option required
Refer to accessory section for shield options
9 Nighttime FriendlyTM optic

Optic Distribution
03S
05S
07S
10S
15S
20S
25S
17M
25M

R2 SG
N
N
N
N
N
N
N
N
N

R3 SG
N
N
N
N
N
N
N

R2 FG
N
N
N
N
N
N
N
N1
N1

R3 FG R2 FG HPR3 FG HP
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N1
N1
-

Notes:
1 Use deluxe/coated lamp LD option

Product Guide

21

Roadway Series 315


Roadway Lighting with Power Door
35-400W HPS, 175-250W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Die-cast secondary Power Pad door places all electrical components on one
easily interchangeable module with quick disconnects to main fixture housing
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Optional four-bolt
mounting provides extra security in high-vibration applications
Die-cast trigger latch on lens frame enables easy and secure one-hand
opening for re-lamping
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) on the two-bolt
unit and is easily adjustable for 1-1/4" to 2" (1-5/8 to 2-3/8 O.D.) mast arms
Photocontrol receptacle is adjustable without tools

Applications:

Anodized aluminum reflectors provide uniform lighting distribution with


borosilicate glass, acrylic or polycarbonate refractor

Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard
All electrical components warranted by American Electric Lighting's 6-year
guarantee
E39 mogul base socket standard
Suitable for -30C MH / -40C HPS
DIMENSIONS

Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31

PREFERRED SELECTION CATALOG NUMBERS

315 10S CA MT1 R2 DA EC


315 10S RN 120 R2 DA EC
315 15S RN 120 R2 DA EC

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire Series 315 is 0.9 sq. ft.
Approx. Wt. = 19 lbs.

22

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 315


Roadway Lighting with Power Door
35-400W HPS, 175-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: 3 1 5 1 0 S M R D T 2 R 3 D G N R B L

Wattage / Source

Series
315 Power Door
Cobrahead

03
05
07
10
13

35W
S HPS
50W
M MH
70W
100W
100/150W
Wired 100W
14 100/150W
Wired 150W
15 150W
17 175W
20 200W
25 250W
40 400W
Refer to the ballast matrix on
page 54 for compatibility.

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

120
208
220
240
277
347
480
MT1
MT2
MT7
TT3
DT2

120V
208V
220V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V

Distribution
R2 Roadway Type II
R3 Roadway Type III
RX Roadway Type II
4-way2

Refer to optic distribution


matrix below for compatibility.
Optics
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor
DG Drop Glass
Prismatic Refractor

Options
Mounting
(blank) 2-bolt Internal
EF External Fitter (2-bolt only)
4B 4-bolt Internal
M2 2-bolt Internal 2 setting
E2 External Fitter 2 Mast Arm
(2-bolt only)
Paint3
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)4
Listing
UL
CS
Fusing5
SF
DF

UL Listed
CSA Certified

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle6
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
PC
BL
SS
CF
PL
LA
5H
NN
SH
HK
BF
RG

Photocontrol Included per


Voltage Specified6
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle1
No NEMA Label on Housing
Shorting Cap6
Hinge Keeper
3G Vibration8
Rubber Silicone Optical Gasket

Notes:
1 Limited availability, please contact your local
American Electric Lighting representative
2 DG option only
3 Other colors available, please contact your local
American Electric Lighting representative
4 T3 option only available with 240, 480, DT2, DT4, MT2
5 Not available in MT, TT, DT voltages
6 SH, PC not available with with NR option
7 Available in HPS only
8 Tested to withstand 3G vibration, 4B option required

Optic Distribution
03S
05S
07S
10S
15S
20S
25S
31S
40S
17M
25M

R2DA R3DA R2DP R3DP R2DG R3DG RXDG


N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Product Guide

23

Roadway Series 315


Roadway Lighting Cutoff Style with Power Door
35-400W HPS, 175-250W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance. Die-cast secondary Power Pad door places all electrical
components on one easily interchangeable module with quick disconnects to
main fixture housing
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Optional four-bolt
mounting provides extra security in high-vibration applications
Die-cast trigger latch on lens frame enables easy and secure one-hand
opening for re-lamping
Large surface area breathing seal gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) on the two-bolt
unit and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms
Photocontrol receptacle is adjustable without tools

Applications:

Anodized aluminum reflectors provide uniform lighting distribution with either


flat or sag clear tempered glass

Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard
All electrical components warranted by American Electric Lighting's 6-year
guarantee
E39 mogul socket standard
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31
Suitable for -30C MH / -40C HPS

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS


27"
(686)

315 10S CA MT1 R2 FG EC


315 25S CA MT1 R2 FG EC
315 15S CA MT1 R2 FG EC

6-1/2"
(165)

13"
(330)
6-1/2"
(165)

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire Series 315
with Cutoff is 0.98 sq. ft.
Approx. Wt. = 19 lbs.

24

Product Guide

Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315
with sag glass is 1.06 sq. ft.

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 315


Roadway Lighting Cutoff Style with Power Door
35-400W HPS, 175-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: 3 1 5 1 0 S C A D T 2 R 3 F G N R H P

Wattage / Source

Series
315 Power Door
Cobrahead

03
05
07
10
13

35W
S HPS
50W
M MH
70W
100W
100/150W
Wired 100W
14 100/150W
Wired 150W
15 150W
17 175W
20 200W
25 250W
40 400W
Refer to the ballast matrix on
page 54 for compatibility.

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

Distribution

R2 Roadway Type II
120V
208V
R3 Roadway Type III
240V
277V
Refer to optic distribution
347V
matrix below for compatibility.
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Optics
Multi-tap Wired 277V
Tri-tap Wired 277V
FG Flat Glass Clear Tempered9
Tri-tap Wired 347V
SG Sag Glass Clear Tempered
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V

120
208
240
277
347
480
MT1
MT2
MT7
TT7
TT3
DT2

Options
Mounting
(blank) 2-bolt Internal 1-1/4 Setting
(standard)
EF External Fitter (2-bolt only)
4B 4-bolt Internal
M2 2-bolt Internal 2 Setting
E2 External Fitter 2 Mast Arm
(2-bolt only)

Lamp
LC
LD

Paint2
(blank)
BK
BZ
WH
UP

Misc.
PC

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)3
Listing
UL
CS

UL Listed
CSA Certified

Fusing4
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle5

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter6
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in

BL
SS
CF
PL
LA
5H
NN
SH
HK
HP
BF
RG

Photocontrol Included per


Voltage Specified5
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle1
No NEMA Label on Housing
Shorting Cap5
Hinge Keeper
High Performance7
RG Vibration8
Rubber Silicone Optical Gasket

Notes:
1 Limited availability, please contact your local
American Electric Lighting representative
2 Other colors available, please contact your local
American Electric Lighting representative
3 T3 option only available with 240, 480, DT2, DT4, MT2
4 Not available in MT, TT, DT voltages
5 PC, SH, not available in NR option
6 Available in HPS only
7 FG Optics only
8 Tested to withstand 3G vibration, 4B option required
9 Nighttime FriendlyTM optic
Refer to accessory section for shield options

Optic Distribution
03S
05S
07S
10S
15S
20S
25S
40S
17M
25M

R2SG R3SG R2FG R3FG R2FGHP R3FGHP


N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N1
N1
N
N1
N1
-

Notes:
1 Use deluxe/coated lamp LD option

Product Guide

25

Roadway Series 125


Roadway Lighting
200-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Optional two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standard
four-bolt mounting provides extra security in high-vibration applications
Die-cast trigger latch on doorframe enables easy and secure one-hand
opening for re-lamping and maintenance
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) with 2B option
and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-2/8" O.D.) mast arms
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution with either
borosilicate glass, or polycarbonate refractor

Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard
All electrical components warranted by American Electric Lighting's 6-year
guarantee
E39 mogul socket standard
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
Suitable for -30C MH / -40C HPS

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

125 25S CA MT1 R3 DG EC


125 40S CA MT1 R3 DG EC
125 40M SC MT1 R3 DG

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire series 125 is 1.30 sq. ft.
Approx. Wt. = 35 lbs.

26

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 125


Roadway Lighting
200-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 1 2 5 4 0 S C A M T 1 R 3 D G L C P C

Wattage / Source

Series
125 Single Door
Cobrahead

17
20
25
31
40
23

175W
200W
250W
310W
400W
250/400W
Wired 2501
24 250/400W
Wired 4001

S HPS
M MH

Refer to the ballast matrix on


page 54 for compatibility.

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

Distribution

R2 Roadway Type II
120V
R3 Roadway Type III
208V
R4 Roadway Type IV
240V
277V
Refer to optic distribution
347V
matrix below for compatibility.
480V
Multi-tap Wired 120V
Optics
Multi-tap Wired 240V
Multi-tap Wired 277V
DP Drop Polycarbonate
Tri-tap Wired 347V
Prismatic Refractor
Dual Tap 120/240
DG Drop Glass
Wired 240V
Prismatic Refractor
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap Wired 480V2
120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Options
Mounting
(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2 Setting
2B 2-bolt Internal 1-1/4 Setting
Paint3
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)4

Lamp
LC
LD

Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
PC
BL
SS
CF
PL
LA

Listing
UL
CS

UL Listed
CSA Certified

Fusing5
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle6

Lamp Included, Clear


Lamp Included, Deluxe/Coated

5H
NN
SH
HK
RG

Photocontrol Included per


Voltage Specified6
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle8
No NEMA Label on Housing
Shorting Cap6
Hinge Keeper
Rubber Silicone Optical Gasket

Notes:
1 5-tap not available
2 Available in 250W and 400W
3 Other colors available, please contact your local
American Electric Lighting representative
4 T3 option only available with 240, 480, DT2, DT4, MT2
5 Not available with MT, TT, DT voltages
6 PC and SH not available in NR option
7 Available in HPS only
8 Limited availability, please contact your local
American Electric Lighting representative

Optic Distribution
20S
25S
31S
40S
17M
25M
40M

R2DP R3DP R2DG R3DG R4DG


N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-

Product Guide

27

Roadway Series 125


Roadway Lighting Cutoff Style
200-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Optional two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standard
four-bolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on doorframe enables easy and secure one-hand
opening for re-lamping and maintenance
Large surface area breathing seal gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture
Wildlife shield is cast into the housing (not a separate piece) with 2B option
and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms
Photocontrol receptacle is adjustable without tools
Anodized aluminum reflectors provide uniform lighting distribution with either
flat or sag clear tempered glass

Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

NEMA wattage label, terminal block, and photocontrol receptacle are standard
All electrical components warranted by American Electric Lighting's 6-year
guarantee
E39 mogul socket standard
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31
Suitable for -30C MH / -40C HPS
DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

125 25S CA MT1 R3 FG EC


125 40S CA MT1 R3 FG EC

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire series 125 Cutoff is 1.14 sq. ft.
Approx. Wt. = 35 lbs

28

Product Guide

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire Series 125 with sag glass is 1.22 sq. ft.

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 125


Roadway Lighting Cutoff Style
200-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 1 2 5 4 0 S C A M T 1 R 3 F G L C P C

Wattage / Source

Series
125 Single Door
Cobrahead

17
20
25
31
40
23

175W
S HPS
200W
M MH
250W
310W
400W
250/400W
Wired 2501
24 250/400W
Wired 4001
Refer to the ballast matrix on
page 54 for compatibility.

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Distribution

R2 Roadway Type II
120V
R3 Roadway Type III
208V
240V
Refer to optic distribution
277V
matrix below for compatibility.
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Optics
Multi-tap Wired 277V

Tri-tap Wired 347V


Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap Wired 480V2

FG Flat Glass Clear Tempered10


SG Sag Glass Clear Tempered

Options
Mounting
(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2 Setting
2B 2-bolt Internal 1-1/4 Setting
Paint3
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)4

Lamp
LC
LD

Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
PC
BL
SS
CF
PL
LA

Listing
UL
CS

UL Listed
CSA Certified

Fusing5
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle6

Lamp Included, Clear


Lamp Included, Deluxe/Coated

5H
SH
HK
HP
RG

Photocontrol Included per


Voltage Specified6
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle9
Shorting Cap6
Hinge Keeper
High Performance8
Rubber Silicone Optical Gasket

Notes:
1 Not available in 5-tap
2 Available in 250W and 400W
3 Other colors available, please contact your local
American Electric Lighting representative
4 T3 option only available with 240, 480, DT2, DT4, MT2
5 Not available with MT, TT, DT voltages
6 PC, SH, not available in NR option
7 Available in HPS only
8 FG Optics only
9 Limited availability, please contact your local
American Electric Lighting representative
10 Nighttime FriendlyTM optic

Optic Distribution
20S
25S
31S
40S
17M
25M
40M

R2SG R3SG R2FG R3FG R2FGHP R2FGHP


N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-

Product Guide

29

Roadway Series 325


Roadway Lighting with Power Door
200-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Die-cast secondary Power Pad door places all electrical components on one
easily interchangeable module with quick disconnects to main fixture housing.
Optional two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standard
four-bolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on lens frame enables easy and secure one-hand
opening for re-lamping.
Large surface area breathing seal gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) with 2B option
and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms.

Applications:

Photocontrol receptacle is adjustable without tools.

Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

Anodized aluminum reflectors provide uniform lighting distribution with either


borosilicate glass or polycarbonate refractor.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee
E39 mogul socket standard
DIMENSIONS

Suitable for -30C MH / -40C HPS


Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31

PREFERRED SELECTION CATALOG NUMBERS

325 25S CA MT1 R3 DG EC


325 40M SC MT1 R3 DG
325 40S CA MT1 R3 DG EC
325 40M SC 480 R3 DG

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire Series 325 is 1.30 sq. ft.
Approx. Wt. = 35 lbs.

30

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 325


Roadway Lighting with Power Door
200-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 3 2 5 4 0 M C A M T 7 R 3 D G B K L C

Series
325 Power Door
Cobrahead

Wattage / Source
17
20
25
31
40
23

175W
S HPS
200W
M MH
250W
310W
400W
250/400W
Wired 250W1
24 250/400W
Wired 400W1
Refer to the ballast matrix on
page 55 for compatibility.

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

Distribution

R2 Roadway Type II
120V
R3 Roadway Type III
208V
R4 Roadway Type IV
240V
277V
Refer to optic distribution
347V
matrix below for compatibility.
480V
Multi-tap Wired 120V
Optics
Multi-tap Wired 240V
Multi-tap Wired 277V
DP Drop Polycarbonate
Tri-tap Wired 347V
Prismatic Refractor
Dual Tap 120/240
DG Drop Glass
Wired 240V
Prismatic Refractor
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap wired 480V2
120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Options
Mounting
(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2 Setting
2B 2-bolt Internal 1-1/4 Setting
Paint3
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)4

Lamp
LC
LD

Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
PC
BL
SS
CF
PL
LA

Listing
UL
CS

UL Listed
CSA Certified

Fusing5
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle6

Lamp Included, Clear


Lamp Included Deluxe/Coated

5H
SH
HK
RG
TL

Photocontrol Included per


Voltage Specified6
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle8
Shorting Cap6
Hinge Keeper
Rubber Silicone Optical Gasket
Tool-less Entry to Power Pad

Notes:
1 Not available in 5-tap
2 Available in 250W and 400W
3 Other colors available, please contact your local
American Electric Lighting representative
4 T3 option only available with 240, 480, DT2, DT4, MT2
5 Not available with MT, TT, DT voltages
6 PC and SH, not available in NR option
7 Available in HPS only
8 Limited availability, please contact your local
American Electric Lighting representative

Optic Distribution
20S
25S
31S
40S
17M
25M
40M

R2DP R3DP R2DG R3DG R4DG


N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-

Product Guide

31

Roadway Series 325


Roadway Lighting Cutoff Style with Power Door
200-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Die-cast secondary Power Pad door places all electrical components on one
easily interchangeable module with quick disconnects to main fixture housing.
Optional two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standard
four-bolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on lens frame enables easy and secure one-hand
opening for re-lamping.
Large surface area breathing seal gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) with 2B option
and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms.

Applications:

Photocontrol receptacle is adjustable without tools.

Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

Anodized aluminum reflectors provide uniform lighting distribution with either


flat or sag clear tempered glass.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee
E39 mogul socket standard

DIMENSIONS

Suitable for -30C MH / -40C HPS


Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31

PREFERRED SELECTION CATALOG NUMBERS

325 25S CA MT1 R3 FG EC


325 40S CA MT1 R3 FG EC

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire Series 325 is 1.14 sq. ft.
Approx. Wt. = 35 lbs

32

Product Guide

Effective Projected Area (EPA) The EPA for the Horizontal Luminaire
Series 325 with sag glass is 1.22 sq. ft.

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 325


Roadway Lighting Cutoff Style with Power Door
200-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 3 2 5 3 1 S C A M T 1 R 3 F G S F B L

Wattage / Source

Series
325 Power Door
Cobrahead

17
20
25
31
40
23

175W
200W
250W
310W
400W
250/400W
Wired 250W1
24 250/400W
Wired 400W1

S HPS
M MH

Refer to the ballast matrix on


page 55 for compatibility.

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
SC SCWA

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2
DT4
5T1
5T2
5T7
5T4

Distribution

R2 Roadway Type II
120V
R3 Roadway Type III
208V
240V
Refer to optic distribution
277V
matrix below for compatibility.
347V
480V
Multi-tap Wired 120V
Optics
Multi-tap Wired 240V
Multi-tap Wired 277V
FG Flat Glass Clear Tempered9
Tri-tap Wired 347V
SG Sag Glass Clear Tempered
Dual Tap 120/240
Wired 240V
Dual Tap 240/480
Wired 480V
5-tap Wired 120V8
5-tap Wired 240V8
5-tap Wired 277V8
5-tap Wired 480V8

Options
Mounting
(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2 Setting
2B 2-bolt Internal 1-1/4 Setting
Paint2
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)3

Lamp
LC
LD

Starter6
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
PC
BL
SS
CF
PL
LA

Listing
UL
CS

UL Listed
CSA Certified

Fusing4
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Lamp Included, Clear


Lamp Included, Deluxe/Coated

5H
SH
HK
HP
TL

Photocontrol Included per


Voltage Specified5
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle8
Shorting Cap5
Hinge Keeper
High Performance7
Tool-less Entry to Power Pad

Notes:
1 Not available in 5-tap
2 Other colors available, please contact your local
American Electric Lighting representative
3 T3 option only available with 240, 480, DT2, DT4, MT2
4 Not available with MT, TT, DT voltages
5 PC and SH, not available in NR option
6 Available in HPS only
7 Available with FG optics only
8 Limited availability, please contact your local
American Electric Lighting representative
9 Nighttime FriendlyTM optic

Optic Distribution
20S
25S
31S
40S
17M
25M
40M

R2SG R3SG R2FG R3FG R2FGHP R2FGHP


N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle5

Product Guide

33

Roadway Series 327


Roadway Lighting
1000W HPS, 1000W MH

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Four-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter and extra security in
high-vibration applications.
Die-cast trigger latch on doorframe enables easy and secure one-hand
opening for re-lamping and maintenance
Large surface area breathing seal gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Anodized aluminum reflectors provide uniform lighting distribution with
standard borosilicate glass refractor.
Photocontrol receptacle is adjustable without tools
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.

Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks

All electrical components warranted by American Electric Lighting's 6-year


guarantee
E39 mogul socket standard
Complies with ANSI: C136.2, C136.10, C136.14, C136.15
Suitable for -30C MH / -40C HPS

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

327 X1S CA MT1 R3 DG


327 X1M CA MT1 R3 DG

38.3"
(973)

16-1/4"
(413)

17-1/2"
(445)

16-1/4"
(413)

Effective Projected Area (EPA)


The EPA for the Horizontal Luminaire Series 327 is 1.96 sq. ft.
Approx. Wt. = 60 lbs

34

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 327


Roadway Lighting
1000W HPS, 1000W MH

O R D E R I N G

I N F O R M AT I O N

Example: 3 2 7 X 1 M C A M T 1 R 3 D G L C P C

Wattage / Source

Series
327 Single Door
Cobrahead

X1 1000W

S HPS
M MH

Voltage

Ballast
CA CWA
SC SCWA

Refer to the ballast matrix on


page 55 for compatibility.

120
208
240
277
480
MT1
MT2
MT7
5T4

120V
208V
240V
277V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
5-tap Wired 480V1

Distribution
R1 Roadway Type I
R2 Roadway Type II
R3 Roadway Type III

Refer to optic distribution


matrix below for compatibility.

Optics
DG Drop Glass
Prismatic Refractor

Options
Paint2
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)3
Fusing4
SF
DF

Single Fuse (120, 277V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle5

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Notes:
1
2

Misc.
PC
BL
SS
PL
LA
SH

Photocontrol Included per


Voltage Specified5
Bubble Level
Stainless Steel Fasteners (external)
Distribution Pattern
Indicator Label
Lightning Arrestor
Shorting Cap5

3
4
5

Limited availability, please contact your local


American Lighting representative
Other colors available, please contact your local
American Electric Lighting representative
T3 option only available with 240, 480, DT2, DT4, MT2
Not available with MT voltages
PC and SH not available with NR option

Optic Distribution
X1S
X1M

R1DG R2DG
N
N

R3DG
N
N

Product Guide

35

Roadway Series 285


Roadway Lighting Set-Back
200-400W HPS, 250-400W MH

P R O D U C T

O V E R V I E W

Features:
Unique optical design allows set-back of mounting poles away from traffic
areas, while still delivering superior performance.
Light pattern allows exceptional spacing to mounting height ratios, permitting
fewer luminaries per mile
Anodized aluminum reflector provides uniform lighting distribution with drop
acrylic prismatic refractor.
Adjustable and locking knuckle mount provides for precise and secure aiming
of the luminaire
Suitable for 2-3/8 to 3 O.D. tenons
Latch on lens frame enables easy and secure one-handed opening for
re-lamping
Photocontrol receptacle is adjustable without tools
All electrical components warranted by American Electric Lighting's 6-year
guarantee

Applications:

Suitable for -30C MH / -40C HPS

Interstate roadways
Broad commercial and residential roadways
Large parking areas

Complies with ANSI: C136.2, C136.10, C136.15, C136.31

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

285 25S CA MT1 R3 DA GY


285 40S CA MT1 R3 DA GY

Effective Projected Area (EPA)


The EPA for the MultiMount Luminaire Series 285 is 2.8 sq. ft.
Approx Wt. = 42 lbs

36

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Series 285


Roadway Lighting Set-Back
200-400W HPS, 250-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 2 8 5 4 0 S C A M T 1 R 3 D A L C

Wattage / Source

Series
285 Multi-Mount
Roadway

S HPS
M MH

20
25
31
40
23

200W
250W
310W
400W1
250/400W
Wired 250
24 250/400W
Wired 4001

Voltage

Ballast

Refer to the ballast matrix on


page 56 for compatibility.

RN Reactor Normal Power Factor


RH Reactor High Power Factor
XN High Reactance (Lag)
Normal Power Factor
XH High Reactance (Lag)
High Power Factor
CA CWA
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2
DT4

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240 Wired 240V
Dual Tap 240/480 Wired 480V

Distribution
R3 Roadway
Type III2

Optics
DA Drop Acrylic
Prismatic
Refractor

Options
Paint3
(blank)
BK
WH
UP
GY

Bronze (standard)
Black
White
Unpainted
Gray

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 and L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)4
Fusing5
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle6

Lamp
LC
LD

Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated

Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
PC
HK
SS
PL
LA
NL
SH

1
2
3
4
5
6
7

400 MH requires reduced jacket ED-28 lamp


Distribution depends on tilt angle of fixture
Other colors available, please contact your local
American Electric Lighting representative
T3 option only available with 240, 480, DT2, DT4, MT2
Not available with MT, TT, DT voltages
PC and SH not available with NR option
For HPS only

Photocontrol Included
per Voltage Specified6
Hinge Keeper
Stainless Steel Fasteners (external)
Distribution Pattern Indicator Label
Lightning Arrestor
NEMA Label
Shorting Cap6

Product Guide

37

InterState II Series 775


Roadway Lighting Interstate with Contemporary Style
200-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
Unique optical design allows set-back of mounting poles away from traffic
areas, while still delivering superior performance
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Slim profile provides a low EPA
Door is hinged and easily removable for quick maintenance
Anodized aluminum reflector provides uniform lighting distribution with sag or
flat glass clear tempered refractor
Adjustable and locking knuckle mount provides for precise and secure aiming
of the luminaire
Suitable for 2-3/8 to 3 O.D. tenons
Photocontrol receptacle is adjustable without tools
For fast relamping optional tool-less access is available
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard

Applications:

All electrical components warranted by American Electric Lighting's 6-year


guarantee

Interstate roadways
Expressways
Railway switchyards
Shipping docks
Large parking lots

Suitable for -30C MH / -40C HPS


Complies with ANSI: C136.2, C136.3, C136.10, C136.15, C136.31

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

Yoke Mount

775 25S CA MT1 R3 FG


775 25S CA MT1 R3 SG
775 40M SC MT1 R3 SG
775 40S CA MT1 R3 SG

Vertical Tenon Mount

19.5"
(495)

1" (25)
2" (51)

.44" (11) Dia.


1" (25)
.78" (20) Dia.

Effective Projected Area (EPA)


The EPA for the InterState II is 2.75 sq. ft.
Approx. Wt. = 37 lbs

38

Product Guide

2" (51)

For photometric information, visit our website,


www.americanelectriclighting.com

InterState II Series 775


Roadway Lighting Interstate with Contemporary Style
200-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 7 7 5 4 0 S C A 4 8 0 R 3 S G

Wattage / Source

Series
775 InterState
Roadway
Offset

Voltage

Distribution

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap Wired 480V3

R3 Roadway
Type III4

Ballast
RN
RH
XN

17
20
25
31
40
23

175W
S HPS
200W
M MH
250W
310W
400W
250/400W
Wired 250W1
24 250/400W
Wired 400W1

XH

Refer to the ballast matrix on


page 56 for compatibility.

CA
CT
MR
SC

Reactor Normal Power Factor


Reactor High Power Factor
High Reactance (Lag)
Normal Power Factor
High Reactance (Lag)
High Power Factor
CWA
CWI
Mag Reg (3 Coil)
SCWA2

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Optics
SG Sag Glass
Clear Tempered
FG Flat Glass
Clear Tempered

Options
Mounting
(blank) Tenon Slipfitter (standard)4
YG Yoke Galvanized
YP Yoke Painted5

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle9

Paint6
(blank)
BK
BZ
WH
UP

Lamp
LC
LD

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 and L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)7
Standard Listing
(blank) UL Listed (standard)
CS CSA Certified
Fusing8
SF
DF

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter10
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
PC
TL
SS
PL
LA
5H
SH

Notes:
1
2
3
4
5
6
7
8
9
10

Not available in 5-tap


Limited availability, please contact your local
American Electric Lighting representative
250W and 400W only
Distribution depends on tilt angle of fixture
Painted to match specified color of fixture
Other colors available, please contact your local
American Electric Lighting representative
T3 option only available with 240, 480, DT2, DT4, MT2
Not available with MT, TT, DT voltages
PC, SH not available with NR option
For HPS Products only

Photocontrol Included
per Voltage Specified9
Tool-less Entry
Stainless Steel Fasteners (external)
Distribution Pattern Indicator Label
Lightning Arrestor
50 Hertz Ballast Cycle2
Shorting Cap9

Single Fuse (120, 277, 347V)


Double Fuse (208, 240, 480V)

Product Guide

39

LPS Roadway Series SRX


Roadway Lighting
35-90W LPS

P R O D U C T

O V E R V I E W

Features:
Designed for maximum energy savings with efficient light distribution
Vandal resistant, rugged and corrosion resistant die cast aluminum housing
Drop polycarbonate prismatic refractor allows for maximum control of light
distribution
Large surface area "breathing seal," gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heatresistant gasket material remains effective over the life of the fixture.
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Complies with ANSI: C136.2, C136.10

Applications:
Roadways
Highways
Transportation terminals

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

SRX 55L XH DT1 R4 DP LC


SRX 55L XH 480 R4 DP NR

4-1/2"
(114)

4"
(102)
27"
(686)

7-1/2"
(191)

9"
(229)

Effective Projected Area (EPA)


The EPA for the Roadway Luminaire Series SRX is 1.00 sq. ft.
Approx. Wt. = 20 lbs.

40

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

LPS Roadway Series SRX


Roadway Lighting
35-90W LPS

O R D E R I N G

I N F O R M AT I O N

Example: S R X 0 9 L R H 4 8 0 R 4 D P L C

Wattage / Source

Series
SRX Low Pressure
Sodium Roadway

03 35W
55 55W
09 90W

L LPS

Refer to the ballast matrix on


page 57 for compatibility.

Voltage

Ballast
RH Reactor High Power
Factor
XH High Reactance (Lag)
High Power Factor

120
208
240
277
347
480
DT1

120V
208V
240V
277V
347V
480V
Dual Tap 120/240
Wired 120V
DT2 Dual Tap 120/240
Wired 240V
DT5 Dual Tap 208/277
Wired 208V
DT6 Dual Tap 208/277
Wired 277V

Distribution
R4 Roadway
Type IV

Optics
DP Drop Polycarbonate
Prismatic Refractor

Options
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle (standard)
NR No Photocontrol Receptacle1
Lamp
LC

Lamp Included, Clear

Listing
UL

UL Listed

Misc.
PC
SH

Photocontrol Included per Voltage Specified1


Shorting Cap1

Notes:
1

PC and SH not available with NR option

Product Guide

41

LPS Roadway Series SP2


Roadway Lighting
90-180W LPS

P R O D U C T

O V E R V I E W

Features:
Designed for maximum energy savings with efficient light distribution
Outside housing constructed of non-corrosive ABS plastic with UV
inhibiting coating
Drop acrylic or polycarbonate prismatic refractor allows for maximum
control of light distribution
All electrical components warranted by American Electric Lighting's 6-year
guarantee

Applications:
Roadways
Highways
Security lighting
Transportation terminals

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

SP2 09L XH DT1 R4 DP LC


SP2 13L XH DT1 R4 DP LC
SP2 18L XH DT1 R4 DP LC

SERIES

LENGTH (L)

EPA (Sq. Ft.)

SP290

397/16''

1.00

SP213

497/16''

1.20

SP218

637/16''

1.45

Approx. Wt. = 31 lbs

42

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

LPS Roadway Series SP2


Roadway Lighting
90-180W LPS

O R D E R I N G

I N F O R M AT I O N

Example: S P 2 1 8 L X H 4 8 0 R 4 D P L C

Series

Wattage / Source
09 90W
13 135W
18 180W

SP2 Low Pressure


Sodium
Roadway

L LPS

Refer to the ballast matrix on


page 57 for compatibility.

Voltage

Ballast
RH Reactor High
Power Factor
XH High Reactance
(Lag) High Power
Factor

120
208
240
277
347
480
DT1

120V
208V
240V
277V
347V
480V
Dual Tap Wired
120/240 Wired 120V
DT2 Dual Tap Wired
120/240 Wired 240V
DT5 Dual Tap 208/277
Wired 208V
DT6 Dual Tap 208/277
Wired 277V

Distribution
R4 Roadway
Type IV

Optics
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor

Options
Listing
UL
CS

UL Listed
CSA Certified

Notes:
1 PC and SH not available with NR option

Photocontrol Receptacle
(blank) With Photocontrol Receptacle
NR No Photocontrol Receptacle1
Lamp
LC

Lamp Included, Clear

Misc.
PC
SH

Photocontrol Included per Voltage 1


Shorting Cap1

Product Guide

43

Underpass Series 581/681


Roadway Lighting
50-250W HPS, 175-250W MH

P R O D U C T

O V E R V I E W

Features:
Low profile design for unobtrusive surface mounting
Die-cast aluminum back housing with choice of die-cast front housing with
borosilicate glass lens, or one-piece polycarbonate front housing and lens
Designed for easy access to electrical compartment and optical assembly
for installation and maintenance ease
All exterior hardware is captive
UL and CSA listed for wet locations
All electrical components warranted by American Electric Lighting's 6-year
guarantee
E39 mogul socket standard
Suitable for -30C MH / -40C HPS

Applications:
Office complexes
Shopping centers and malls
Schools and hospitals
Parking garages
Tunnel and underpasses
Parks

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

581 15S CA 120


581 15M XN MT1
681 10S RN 120
681 15S RN 120
681 15M XN MT1

Approx. Wt. = 30 lbs

44

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Underpass Series 581/681


Roadway Lighting
50-250W HPS, 175-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: 5 8 1 2 5 S C A M T 1 G Y

Wattage / Source

Series
581 Wallpack w/
Die-cast and
Glass Front
housing
681 Wallpack w/
Polycarbonate
Front Housing1

S HPS
05 50 W
M MH
07 70 W
10 100 W
15 150 W
17 175 W
20 200 W
25 250 W
Refer to the ballast matrix on
page 57 for compatibility.

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance (Lag)
Normal Power Factor
XH High Reactance (Lag)
High Power Factor
CA CWA
CT CWI

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2
DT4

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240 Wired 240V
Dual Tap 240/480 Wired 480V

Options
Mounting
(blank) Wall Mount (standard)
Paint2
(blank)
BK
WH
GY
UP

Bronze (standard)
Black
White
Gray
Unpainted

Listing
(blank)
CS

UL Listing (standard)
CSA Certified

Fusing3
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 240, 480V)

Photocontrol Receptacle
(blank) Button Control (standard)
(multi-volt options not available)
NC No Photocontrol

Notes:
1
2
3
4

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc.
SE
SS
5H
NL

Side Entry
Stainless Steel Fasteners (external)
50 Hertz Ballast Cycle4
NEMA Label

Max Wattage 175W, only available in bronze


Other colors available, please contact your local
American Electric Lighting representative
Not available with MT, TT, DT voltages
Limited availability, please contact your local
American Electric Lighting representative

Product Guide

45

Heavy Duty Wallpack Series 882


Roadway Lighting Building Mounted
200-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
Designed for easy access to electrical compartment and optical assembly
for installation and maintenance ease
Heavy duty, two piece, die cast aluminum housing with hinged, captive
bezel and corrosion resistant hardware
Completely sealed with high temperature silicone gasket
High impact and heat resistant borosilicate glass refractor
One piece, stippled, asymmetric anodized aluminum reflector designed to
produce a wide pattern of efficient illumination
UL and CSA certified for wet locations
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30C MH / -40C HPS

Applications:
Parking areas
Perimeter lighting
Entrances and walkways
Waterfront areas
Loading platforms
Recreational areas

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

882 25S CA MT7


882 40M CA 5T4

Approx. Wt. = 36 lbs

46

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Heavy Duty Wallpack Series 882


Roadway Lighting Building Mounted
200-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 8 8 2 2 5 S C A M T 1

Wattage / Source

Series
882 Wallpack

17
20
25
31
40

175W
200W
250W
310W
400W

S HPS
M MH

Voltage

Ballast
CA CWA
CT CWI
MR Mag Reg

480
MT1
MT2
MT7
MT8
5T4

480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Multi tap Wired 208V
5-tap Wired 480V

Refer to the ballast matrix on


page 58 for compatibility.

Options
Listing
(blank)
CS

UL Listed (standard)
CSA Certified

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Product Guide

47

SignLite Series 875


Roadway Lighting Sign Light
175-400W MH, 200-400W HPS

P R O D U C T

O V E R V I E W

Features:
Die cast low copper aluminum housing offers light weight and corrosion
resistance with excellent durability
Hinged door is easily removable for quick maintenance, tool-less option
makes relamping easy
Anodized aluminum reflector provides uniform lighting distribution with sag
or flat clear tempered glass lens
Rotatable optics
UL listed for wet locations
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.10, C136.15

Applications:
Interstate highways
Outdoor advertising signs
Traffic flow signs
Building facades
Security lighting
Corporate and building lighting
Other vertical surfaces, watts
DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

Yoke Mount

875 25M SC 120 56 SG

Vertical Tenon Mount

19.5"
(495)

1" (25)
2" (51)

.44" (11) Dia.


1" (25)
.78" (20) Dia.
2" (51)

Effective Projected Area (EPA)


The EPA for the Signlite Luminaire, Series 875 is 2.75 sq. ft.
Approx. Wt. = 37 lbs

48

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

SignLite Series 875


Roadway Lighting Sign Light
175-400W MH, 200-400W HPS

O R D E R I N G

I N F O R M AT I O N

Example: 8 7 5 4 0 M C A 4 8 0 6 6 S G

Wattage / Source

Series
875 Sign Light

17
20
25
31
40
23

175W
200W
250W
310W
400W
250/400W
Wired 250W1
24 250/400W
Wired 400W1

Voltage

Ballast

S HPS
M MH

Refer to the ballast matrix on


page 58 for compatibility.

RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor
CA CWA Auto Reg
CT CWI
MR Mag Reg (3 Coil)
SC SCWA

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2
DT4
5T4

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240 Wired 240V
Dual Tap 240/480 Wired 480V
5-tap Wired 480V2

Distribution3
56 5H X 6V NEMA
distribution
66 6H X 6V NEMA
distribution

Optics
SG Sag Glass
Clear Tempered
FG Flat Glass
Clear Tempered

Options
Mounting
(blank) Tenon Mount (standard)4
YG Yoke Galvanized
YP Yoke Painted3
Paint5
(blank)
BK
BZ
WH
UP

Gray (standard)
Black
Bronze
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 and L2 Position
T3 3 Wire Operation (L1, N, L2
Position)6
Listing
(blank)
CS
Fusing7
SF
DF

UL Listed (standard)
CSA Certified

Single Fuse (120, 277, 347V)


Double Fuse (208, 240, 480V)

Photocontrol Receptacle
(blank) Photocontrol Receptacle (standard)
NR No Photocontrol Receptacle8
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter9
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
TL
BT
SS
CF
LA
PC
5H
NL
SH

Tool-less Entry
Ballast Tray
Stainless Steel Fasteners (external)
Charcoal Filter
Lightning Arrestor
(Void UL/CSA Listed Options)
Photocontrol Included per
Voltage Specified8
50 Hertz Ballast Cycle10
NEMA Label
Shorting Cap8

Notes:
1
2
3
4
5

6
7
8
9
10

Not available in 5-tap


250W and 400W only
Distribution depends on tilt angle of fixture
Painted to match specified color of fixture
Other colors available, please contact
your local American Electric Lighting
representative
T3 option only available with 240, 480, DT2, DT4, MT2
Not available with MT, TT, DT voltages
PC, and SH not available with NR option
Available in HPS only
Limited availability, please contact your local
American Electric Lighting representative

Product Guide

49

Accessories
AVA I L A B I L I T Y
115
Glare Shield
House Side Shield, Cutoff
House Side Shield, Drop
Polycarbonate Vandal Shield1
Ballistic Shield for Flat Lens
Ballistic Shield for Flat Lens with Side Protection
Ballistic Shield for Drop Lens
Wireguard1

RK115 GS

315
-

RK125-GS

125

115 HS SHLD EXTERNAL FG/SG

315 HS SHLD EXTERNAL FG/SG

125 HS SHLD EXTERNAL FG/SG

115 HS SHLD EXTERNAL DG

315 HS SHLD EXTERNAL DG

125 HS SHLD EXTERNAL DG

325
-325 HS SHLD EXTERNAL DG

581/681
-

882

RK581 VS

115 PGS FL 25W2

315 PGS FL 25W2

125 PGS FL 40W3

325 PGS FL 40W3

115 PGS FL 25W SPS2

315 PGS FL 25W SPS2

115 PGS DL 25W2

315 PGS DL 25W2

125 PGS DL 40W3

325 PGS DL 40W3

RK581/681 WG

RK882 WG

325 HS SHLD EXTERNAL FG/SG

NOTES:
1 Polycarbonate Vandal shield and Wireguard can not be used simultaneously
2 250W lamp maximum
3 400W lamp maximum

50

Product Guide

Description

Catalog Number

SERIES 115 GLARE SHIELD

RK115 GS

HOUSE SIDE SHIELD FOR FLAT/SAG GLASS


HOUSE SIDE SHIELD FOR DROP GLASS
HOUSE SIDE SHIELD FOR FLAT/SAG GLASS
HOUSE SIDE SHIELD FOR DROP GLASS
HOUSE SIDE SHIELD FOR FLAT/SAG GLASS
HOUSE SIDE SHIELD FOR DROP GLASS
HOUSE SIDE SHIELD FOR FLAT/SAG GLASS
HOUSE SIDE SHIELD FOR DROP GLASS

115 HS SHLD EXTERNAL FG/SG


115 HS SHLD EXTERNAL DG
315 HS SHLD EXTERNAL FG/SG
315 HS SHLD EXTERNAL DG
125 HS SHLD EXTERNAL FG/SG
125 HS SHLD EXTERNAL DG
325 HS SHLD EXTERNAL FG/SG
325 HS SHLD EXTERNAL DG

POLYCARBONATE SHIELD
FOR SIDELITE 581

RK581 VS

For photometric information, visit our website,


www.americanelectriclighting.com

Accessories
S H I E L D S
Description

BALLISTIC SHIELDS

W I R E

G U A R D S

Catalog Number

RK115 or 315 PGS FL 25W


RK115 or 315 PGS FL 25W SPS
RK115 or 315 PGS DL 25W
RK115 or 315 PGS DL 25W SPS
RK125 or 325 PGS FL 40W
RK125 or 325 PGS DL 40W

6.25"
(159)

8.67"
(220)

WIRE GUARDS

RK581/681 WG
RK882 WG

6.50"
(194)
17"
(432)

16.63"
(422)

6.50"
(165)

Product Guide

51

Roadway Lighting
B A L L A S T

M AT R I C E S

Corvus CVM
Watts
07S
10S
15S
13S
14S
17M
20S
25S
25M
40S

120
CA,CT,MR,RH,RN
CA,CT,MR,RH,RN
CA,CT,MR,RH,RN
RN,RH
RN,RH
CA
CA,CT,XN,XH
CA,CT,XN,XH
CA,CT
-

208
XH,CA,XN
CA,CT,XN,XH
CA,CT,XN,XH
CA
CA,CT
CA,CT
CA
RN,RH

240
CA,MR,XH,XN
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA
CA,XN,XH
CA,CT,XN,XH
CA,CT
RN,RH

277
XH,CA,CT,XN
CA,XH,XN
XN,XH,CA,CT
CA
CA,CT
CA,CT
CA,CT
-

347
XH,XN
CT,XH,XN
CA, CT,XH,XN
CA
CA
CA,CT

480
DT2
XH,XN
CA,CT,MR,XH,XN
CA,CT,XN CA,CT,MR,XH,XN
CA,MR,XN,XH CA,CT,MR,XH,XN
CA
CA
CA,CT
CA,CT,XN,XH
CA
CA,CT,XN,XH
CA,CT
CA,CT
-

DT4
MR
MR
CT
-

Corvus CVM continued


Watts
07S
10S
15S
13S
14S
17M
20S
25S
25M
40S

MT1
CA,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA,CT
CA,CT
CA
-

MT2
CA,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA,CT
CA,CT
CA
-

MT7
CA,XH,XN
CA,CT,XN,XH
CA,CT,XH,XN
CA
CA,CT
CA,CT
CA
-

TT3
CT,XH,XN
CT,XH,XN
XH,XN
CA
CA,CT
CA,CT
-

Corvus CVL
Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

120
CA
CA,CT,MR,XN,XH
CA,CT,MR,XN,XH
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT,SC
CA,CT,
CA

208
CA
CA, CT
CA,CT,MR
CA,SC
CA
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT,
CA

240
CA
CA,CT,RN,RH,MR
CA,CT,RN,RH,MR
CA,CT,SC
CA,MR
CA,CT,MR,RN,RH,
CA,CT,SC
CA,CT
CA

277
CA
CA,CT
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

347
CA
CA
CA,CT,SC
CA
CA,CT,SC
-

480
CA
CA,CT,MR
CA,MR
CA,CT
CA,MR
CA,MR
CA
CA
CA

DT2
CA
CA,CT,MR,XN,XH
XN,XH,MR
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT
CA,CT
CA

Corvus CVL continued


Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

MT1
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT2
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT7
CA
CT,CA
CA,CT
CA,SC
CA
CA,CT
CA,SC
CA,CT
CA

TT3
CA
CA,CT
CA,CT,SC
CA
CA,CT,SC
-

5T4
CA
CA
CA
CA
-

DuraStar Series 20
Watts
05S
07S
10S
15S
17M

120
RH,RN
CA,CT,RN,RH,XN,XH
CA,CT,RN,RH,XN,XH
CA,CT,RN,RH,XN,XH
CA,CT

208
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,

240
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,RN,RH,XN,XH
CA,CT

277
XN
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT

480
XH,XN
CA,XN,XH
CA,CT
CA,CT

DT2
CA
CA,CT,XH
CA,CT,XH,XN
CA,CT

DuraStar Series 20 continued


Watts
05S
07S
10S
15S
17M

52

MT1
XN,XH
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN

Product Guide

MT2
XN,XH
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN

MT7
XN,XH
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN

TT3
XN,XH
XN,XH
XN,XH
CA

For photometric information, visit our website,


www.americanelectriclighting.com

DT4
CA
-

DT4
MR
MR
MR
CT
-

Roadway Lighting
B A L L A S T

M AT R I C E S

DuraStar Series 30
Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

120
CA
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA,CT,SC
CA,MR
CA,CT,MR,XH,XN
CA,CT,SC
CA
CA

208
CA,CT
CA,CT
CA,CT
CA,SC
CA,MR
CA,CT,RH,RN
CA,SC
CA
CA

240
CA
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA,CT,SC
CA,MR
CA,CT,MR,XH,XN,RH,RN
CA,CT,SC
CA
CA

277
CA
CA,CT
CA,CT
CA,SC
MR,CA
CA,CT
SC,CA,CT
CA
CA

347
CA
CA
CA
CA,CT,SC
-

480
CA
CA,CT
CA,MR
CA,SC
CA,MR
CA,MR
CA,CT
-

DT2
CA,CT
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA
CA,MR
MR
CA,CT,SC
CA
CA

5T4
CA
CA
CA
CA
-

DuraStar Series 30 continued


Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

DT4
MR
MR
-

MT1
CA
CA,CT
CA,CT
CA,SC
CA
CA,CT
SC,CA
CA
CA

MT2
CA
CA,CT
CA,CT
CA,SC
CA
CA,CT
SC,CA
CA
CA

MT7
CA
CA,CT
CA,CT
CA,SC
CA
CA,CT
CA,SC
CA

TT3
CA
CA
CA
CA
-

Roadway 115
Watts
03S
05S
07S
10S
15S
13S
14S
17M
20S
25S
25M
40S

120
RN
RH,RN
CA,CT,MR,RH,RN
CA,CT,MR,RH,RN
CA,CT,MR,RH,RN
RN,RH
RN,RH
CA
CA,CT,XN,XH
CA,CT,XN,XH
CA,CT
-

208
XH,CA,XN
CA,CT,XN,XH
CA,CT,XN,XH
CA
CA,CT
CA,CT
CA
RN,RH

240
CA,MR,XH,XN
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA
CA,XN,XH
CA,CT,XN,XH
CA,CT
RN,RH

277
XN
XH,CA,CT,XN
CA,XH,XN
XN,XH,CA,CT
CA
CA,CT
CA,CT
CA,CT
-

347
XH,XN
CT,XH,XN
CA, CT,XH,XN
CA
CA
CA,CT

480
DT2
XH,XN
CA,CT,MR,XH,XN
CA,CT,XN CA,CT,MR,XH,XN
CA,MR,XN,XH CA,CT,MR,XH,XN
CA
CA
CA,CT
CA,CT,XN,XH
CA
CA,CT,XN,XH
CA,CT
CA,CT
-

DT4
MR
MR
CT
-

Roadway 115 continued


Watts
03S
05S
07S
10S
15S
13S
14S
17M
20S
25S
25M
40S

MT1
CA,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA,CT
CA,CT
CA
-

MT2
CA,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA,CT
CA,CT
CA
-

MT7
CA,XH,XN
CA,CT,XN,XH
CA,CT,XH,XN
CA
CA,CT
CA,CT
CA
-

TT3
CT,XH,XN
CT,XH,XN
XH,XN
CA
CA,CT
CA,CT
-

Product Guide

53

Roadway Lighting
B A L L A S T

M AT R I C E S

Roadway 315
Watts
03S
05S
07S
10S
15S
13S
14S
17M
20S
25S
25M
40S

120
RN
RH,RN
CA,CT,MR,RH,RN
CA,CT,MR,RH,RN
CA,CT,MR,RH,RN
RN,RH
RN,RH
CA
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,SC
CA,XH,XN

208
CA,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA,CT
CA,CT
CA,SC
CA

240
CA,MR,XH,XN
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA
CA,CT,RH,RN,XH,XN
CA,CT,RH,RN
CA,CT,SC
CA,RH,RN

277
XN
XH,CA,CT,XN
CA,CT,XH,XN
XH,CA,XN
CA
CA,CT
CA,CT
CA,CT,SC
-

480
XH,XN
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA
CA,CT
CA
CA,CT,SC
CA

DT2
XH,XN
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,SC
-

Roadway 315 continued


Watts
03S
05S
07S
10S
15S
13S
14S
17M
20S
25S
25M
40S

DT4
MR
-

MT1
XH,XN,CA
CA,CT,XN,XH
CA,CT,XN,XH
CA
CA,CT
CA,CT,SC
CA,SC
CA,XN,XH

MT2
CA, XN,XH
CA,CT,XN,XH
CA,CT,XN,XH
CA
CA,CT
CA,CT,SC
CA,SC
CA,XN,XH

MT7
CA, XN,XH
CA,CT,XN,XH
CA,CT,XN,XH
CA
CA,CT
CA,CT,SC
CA,SC
CA,XN,XH

TT3
CT,XN,XH
CT,XN,XH
XN,XH
CA
CA,CT
CA,CT,SC
-

347
XN,XH
CT,XN,XH
XN,XH
CA
CA
CA,CT,SC
-

Roadway 125
Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

120
CA
CA,CT,MR,XN,XH
CA,CT,MR,XN,XH
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT,SC
CA,CT,
CA

208
CA
CA, CT
CA,CT,MR
CA,SC
CA
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT,
CA

240
CA
CA,CT,RN,RH,MR
CA,CT,RN,RH,MR
CA,CT,SC
CA,MR
CA,CT,MR,RN,RH,
CA,CT,SC
CA,CT
CA

277
CA
CA,CT
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

347
CA
CA
CA,CT,SC
CA
CA,CT,SC
-

480
CA
CA,CT,MR
CA,MR
CA,CT
CA,MR
CA,MR
CA
CA
CA

DT2
CA
CA,CT,MR,XN,XH
XN,XH,MR
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT
CA,CT
CA

Roadway 125 continued


Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

54

MT1
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

Product Guide

MT2
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT7
CA
CT,CA
CA,CT
CA,SC
CA
CA,CT
CA,SC
CA,CT
CA

TT3
CA
CA,CT
CA,CT,SC
CA
CA,CT,SC
-

5T4
CA
CA
CA
CA
-

For photometric information, visit our website,


www.americanelectriclighting.com

DT4
MR
MR
MR
CT
-

Roadway Lighting
B A L L A S T

M AT R I C E S

Roadway 325
Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

120
CA
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
CA,CT,SC
CA,MR
CA,CT,MR,XH,XN
CA,CT,SC
CA,CT,
CA

208
CA
CA, CT
CA,CT,MR
CA,SC
CA
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT,
CA

240
CA
CA,CT,MR,RN,RH
CA,CT,MR,RN,RH
CA,CT,SC
CA,MR
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT
CA

277
CA
CA,CT
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

347
CA
CA
CA,CT,SC
CA
CA,CT,SC
-

480
CA
CA,CT,MR
CA,MR
CA,CT
CA,MR
CA,MR
CA
CA
CA

DT2
CA
CA,CT,MR,XH,XN
XN,XH,MR
CA,CT,SC
CA,MR
CA,CT,MR,XH,XN
CA,CT
CA,CT
CA

MT2
CA
CA

MT7
CA
CA

DT4
MR
MR
MR
CT
-

Roadway 325 continued


Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

MT1
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT2
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT7
CA
CT,CA
CA,CT
CA,SC
CA
CA,CT
CA,SC
CA,CT
CA

TT3
CA
CA,CT
CA,CT,SC
CA
CA,CT,SC
-

5T4
CA
CA
CA
CA
-

Roadway 327
Watts
X1S
X1M

120
CA,CT
CA

208
CA,CT
CS

240
CA,CT
CA,SC

277
CA,CT
CA

480
CA,CT
CA

MT1
CA
CA

5T4
CA
XA

Product Guide

55

Roadway Lighting
B A L L A S T

M AT R I C E S

Multi-Mount 285
Watts
20S
25S
25M
31S
40S
40M
23/24S
23/24M

120
CA,CT,MR,XN,XH
CA,CT,MR,XN,XH
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT,SC
CA,CT,
CA

208
CA, CT
CA,CT,MR
CA,SC
CA
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT,
CA

240
CA,CT,MR,RN,RH
CA,CT,MR,RN,RH
CA,CT,SC
CA,MR
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT
CA

277
CA,CT
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

480
CA,CT,MR
CA,MR
CA,CT
CA,MR
CA,MR
CA
CA
CA

DT2
CA,CT,MR,XN,XH
XN,XH,MR
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT
CA,CT
CA

DT4
MR
MR
MR
CT
-

DT2
CA
CA,CT,MR,XN,XH
XN,XH,MR
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT
CA,CT
CA

DT4
MR
MR
MR
CT
-

Multi-Mount 285 continued


Watts
20S
25S
25M
31S
40S
40M
23/24S
23/24M

MT1
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT2
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT7
CT,CA
CA,CT
CA,SC
CA
CA,CT
CA,SC
CA,CT
CA

TT3
CA,CT
CA,CT,SC
CA
CA,CT,SC
-

347
CA
CA,CT,SC
CA
CA,CT,SC
-

5T1
CA
CA
CA
CA
-

Interstate II 775
Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

120
CA
CA,CT,MR,XN,XH
CA,CT,MR,XN,XH
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT,SC
CA,CT,
CA

208
CA
CA, CT
CA,CT,MR
CA,SC
CA
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT,
CA

240
CA
CA,CT,MR,RN,RH
CA,CT,MR,RN,RH
CA,CT,SC
CA,MR
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT
CA

277
CA
CA,CT
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

480
CA
CA,CT,MR
CA,MR
CA,CT
CA,MR
CA,MR
CA
CA
CA

Interstate II 775 continued


Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

56

MT1
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

Product Guide

MT2
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT7
CA
CT,CA
CA,CT
CA,SC
CA
CA,CT
CA,SC
CA,CT
CA

TT3
CA
CA,CT
CA,CT,SC
CA
CA,CT,SC
-

347
CA
CA
CA,CT,SC
CA
CA,CT,SC
-

5T1
CA
CA
CA
CA
-

For photometric information, visit our website,


www.americanelectriclighting.com

Roadway Lighting
B A L L A S T

M AT R I C E S

LPS Roadway SRX


Watts
03L
55L
09L

120
XH
XH
XH

208
XH
XH
XH

240
XH
XH
XH

277
XH
XH
XH

347
XH
XH
XH

480
RH
RH
RH

240
XH
XH
XH

277
XH
XH
XH

347
XH
XH
XH

480
XH
RH,XH
XH

DT1
XH
XH
XH

DT2
XH
XH
XH

DT5
XH
XH
XH

DT6
XH
XH
XH

LPS Roadway SP2


Watts
09L
13L
18L

120
XH
XH
XH

208
XH
XH
XH

DT1
XH
XH
XH

DT2
XH
XH
XH

DT5
XH
XH
XH

DT6
XH
XH
XH

UnderPass Series 581/681


Watts
05S
07S
10S
15S
17M
20S
25S
25M

120
RN
CA,CT,MR,RN RH
CA,CT,RN,RH
CA,MR,RN,RH
CA
XN,XH
XN,XH
CA

208
CA,CT,XN,XH
CA,CT,XN,XH
CA,XN,XH
CA
CA

240
CA,CT,MR,XN,XH
CA,CT,XN,XH
CA,MR,XN,XH
CA
XN,XH
XN,XH
CA

277
CA,XN,XH
CA,CT,XN,XH
CA,XN,XH
CA
CA

480
CA
CA
CA,MR
CA
-

DT2
CA,CT,MR,XN,XH
CA,CT
CA,MR
CA
XN,XH
XN,XH
CA

UnderPass Series 581/681 continued


Watts
05S
07S
10S
15S
17M
20S
25S
25M

DT4
MR
MR
-

MT1
CA
CA,CT
CA
CA
CA

MT2
CA
CA,CT
CA
CA
CA

MT7
CA
CA,CT
CA
CA
CA

MT8
CA
CA,CT
CA
CA
CA

TT1
XN,XH
XN,XH
XN,XH
CA
-

TT3
XN,XH
XN,XH
XN,XH
CA
-

TT7
XN,XH
XN,XH
XN,XH
CA
-

347
XN,XH
CT,XN,XH
XN,XH
CA
-

Product Guide

57

Roadway Lighting
B A L L A S T

M AT R I C E S

Heavy Duty Wallpack 882


Watts
17M
20S
25S
25M
31S
40S
40M

120
CA
CA,CT,MR,XN,XH
CA,CT,MR,XN,XH
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT,SC

208
CA
CA, CT
CA,CT,MR
CA,SC
CA
CA,CT,MR,RN,RH
CA,CT,SC

240
CA
CA,CT,MR,RN,RH
CA,CT,MR,RN,RH
CA,CT,SC
CA,MR
CA,CT,MR,RN,RH
CA,CT,SC

277
CA
CA,CT
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC

480
CA
CA,CT,MR
CA,MR
CA,CT
CA,MR
CA,MR
CA

DT2
CA
CA,CT,MR,XN,XH
MR,XN,XH
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT

DT4
MR
MR
MR
CT

DT2
CA
CA,CT,MR,XN,XH
XN,XH,MR
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT
CA,CT
CA

DT4
MR
MR
MR
CT
-

Heavy Duty Wallpack 882 continued


Watts
17M
20S
25S
25M
31S
40S
40M

MT1
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC

MT2
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC

MT7
CA
CT,CA
CA,CT
CA,SC
CA
CA,CT
CA,SC

TT3
CA
CA,CT
CA,CT,SC
CA
CA,CT,SC

347
CA
CA,CT
CA,CT,SC
CA
CA,CT,SC

5T4
CA
CA
CA
CA

SignLite 875
Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

120
CA
CA, CT, XN, XH MR
XH,XN,CA,CT,MR
CA,CT,SC
CA,MR
CA,CT,XN,XH,MR
CA,CT,SC
CA,CT,
CA

208
CA
CA, CT
CA,CT,MR
CA,SC
CA
CA,CT,MR,RN,RH
CA,CT,SC
CA,CT,
CA

240
CA
CA,CT,RN,RH,MR
CA,CT,RN,RH,MR
CA,CT,SC
CA,MR
CA,CT,RN,RH,MR
CA,CT,SC
CA,CT
CA

277
CA
CA,CT
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

480
CA
CA,CT,MR
CA,MR
CA,CT
CA,MR
CA,MR
CA
CA
CA

SignLite 875 continued


Watts
17M
20S
25S
25M
31S
40S
40M
23/24S
23/24M

58

MT1
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

Product Guide

MT2
CA
CT,CA
CA,CT,MR
CA,SC
CA
CA,CT,MR
CA,SC
CA,CT
CA

MT7
CA
CT,CA
CA,CT
CA,SC
CA
CA,CT
CA,SC
CA,CT
CA

TT3
CA
CA,CT
CA,CT,SC
CA
CA,CT,SC
-

347
CA
CA
CA,CT,SC
CA
CA,CT,SC
-

5T4
CA
CA
CA
CA
-

For photometric information, visit our website,


www.americanelectriclighting.com

DECORATIVE AND POST TOP LIGHTING


Valiant ........................................................................60

Decorative Poles ......................................................90

American Revolution Deluxe Series ....................62

Chadsworth Series................................................90

American Revolution Series 247............................64

New Albany Series ...............................................92

Georgian Series GRP ...............................................66

Statesboro Series..................................................94

Bainbridge Series 870 .............................................68

Waycross Series ...................................................96

Marietta Series.........................................................70

Weatherproof Receptacles .................................98

Sumter Series ...........................................................72

Ballast Matrices .....................................................100

Cresthill Classic ........................................................74


Cresthill Sphere ........................................................76
Cresthill Centennial..................................................78
Cresthill Glass ...........................................................80
Lexington ...................................................................82
Branson......................................................................84
Contempo Series 245 ..............................................86
TwistPack Series TWT ............................................88

American Electric Lighting


59

Valiant

TM

Series AVP
50-250W HPS, 70-250W MH

P R O D U C T

O V E R V I E W

Features:

NEW

Die-cast aluminum housing and hood for long-life performance


Optical assembly designed for maximum performance
Hinged hood and captive screw provision afford quick, easy access to
electrical and optical area for relamping or servicing. Trigger latch (TL) optional
Slipfitter with three set screws allows secure installation to pole sizes 2-3/8"
or 3" O.D.
E39 mogul base socket standard
Tool-less cupola for easy photocontrol adjustment
Tooled cupola lens to prevent wildlife entry into luminaire
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.3.1
Suitable for -30C MH / -40C HPS
40C Rated

Applications:

Encapsulated plug-in starter, standard

Streetscapes
Walkways
Pathways
Parks

Stainless steel fasteners (external), standard


Terminal block, standard

DIMENSIONS
FULL CUTOFF

PREFERRED SELECTION CATALOG NUMBERS


VIEUX OPTION

AVP 13S RH 120 R3 FC NL TL


AVP 10S CA MT1 R3 AY LC PC LDR PA30
AVP 10S CA MT1 R5 AY VX LC PC LDR PA30
AVP 10S RN 120 R3 AY TL
AVP 10S RN 120 R5 AY TL
AVP 13S RH 120 R3 AY NL HS TL

Effective Projected Area (EPA)


The EPA for the Valiant 2.4 sq. ft.
The EPA for the Valiant Vieux is 2.4 sq. ft.
The EPA for the Valiant Full Cutoff is 1.5 sq. ft.
Approx. Wt. = 36 lbs.

60

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Valiant

TM

Series AVP
50-250W HPS, 70-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: A V P 1 7 M C A M T 1 R 3 A Y L C P C L D R P A 3 0

Series
AVP

Valiant Post Top

05
07
10
13
15
17
20
25

Wattage / Source

Ballast

S HPS
50W
M MH
70W
100W
100/150W
150W
175W
200W1
250W

CA CWA
Autotransformer
CT CWI
Autotransformer
SC SCWA2
RH Reactor High
Power Factor
RN Reactor Normal
Power Factor
XH High Reactance/Lag
High Power Factor
XN High Reactance/Lag
Normal Power Factor

Voltage

Refer to ballast matrix on


page 100 for compatibility.

120
208
240
277
347
480
DT1
DT2
MT1
MT2
MT7
MT8
TT3

Distribution

Optics

AY Acrylic
R2 Type II
120V
PY Polycarbonate3
R3 Type III
208V
FC Full Cutoff8
R5 Type V
240V
277V
Refer to optical matrix
347V
below for compatibility
480V
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Multi-tap Wired 120
Multi-tap Wired 240
Multi-tap Wired 277
Multi-tap Wired 208
Tri-tap Wired 347

Options
Post Top Design
VX Valiant Vieux4
Paint
(blank)
GY
WH
Fusing
SF
DF

Black Textured (standard)


Gray
White

Single Fuse (120, 277, 347V)


Double Fuse (208, 240, 480)

Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR PECR with Shorting Cap Installed
Lamp
LC

Listing
UL
CS
Misc.
PC
NL
HS
SH
TL
HP
LDR
PA30
PB30
PC30

Lamp Included, Clear

Notes:
UL Listed
CSA Certified

1
2
3
4
5
6
7
8

Photocontrol Included per


Voltage Specified5
NEMA Label Attached
Houseside Shield4
Shorting Cap5
Tool-less Trigger Latch Entry
High Performance Optics6
Ladder Rest7
Terminal Block Pre-wired 30
# 10 CU Solid B/W/G
Terminal Block Pre-wired 30
# 10 CU Solid B/B/G
Terminal Block Pre-wired 30
# 10 CU Solid B/B/W/G

Available in HPS only


Contact factory for availability
PY available in 175W max
Full cutoff not available
Not available with NR option
Not available with VX or FC options
Ships with unit, field installed
Nighttime FriendlyTM optic

Optic Distribution
05S
07S
10S
15S
20S
25S
17M
25M

R2 AY
N
N
N
N
N
N
N
N

R3 AY
N
N
N
N
N
N
N
N

R5 AY
N
N
N
N
N
N
N
N

R3 AY VX R5 AY VX
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

R3 FC
N
N
N
N
N
N

R2 AY HP R5 AY HP
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Product Guide

61

American Revolution Deluxe


Series ARD and ARD Cutoff
50-150W HPS, 70-175W MH

P R O D U C T

O V E R V I E W

Features:

NEW

Die-cast aluminum housing and hood for long-life performance


Die-cast trigger latch (TL) option available for easy access to internal
components
Optical assembly designed for maximum performance
Hinged hood and captive screw provision afford quick, easy access to
electrical and optical area for relamping or servicing
Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or
3" O.D.
E39 Mogul base socket standard
Meets IESNA Full Cutoff classification
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30C MH / -40C HPS
Tool-less cupola for easy photocontrol adjustment

Applications:

Tooled cupola lens to prevent wildlife entry into luminaire


Complies with ANSI: C136.2, C136.10, C136.15, C136.3.1

Streetscapes
Walkways
Pathways
Parks

40C Rated
Stainless steel fasteners (external), standard
Terminal block, standard
Full cutoff version is Nighttime FriendlyTM
DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

ARD 10S RN 120 R3 AY EC TL


ARD 10S RN 120 R5 AY EC TL
ARD 10M XN MT1 R3 AY TL
ARD 10S CA MT1 R2 FC EC TL

Effective Projected Area (EPA)


The EPA for the American Revolution Series 247 is 1.6 sq. ft.
Approx. Wt. = 36 lbs.

62

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

American Revolution Deluxe


Series ARD and ARD Cutoff
50-150W HPS, 70-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: A R D 1 5 S R N 1 2 0 R 5 A Y E C

Wattage / Source

Series
ARD American
Revolution
Deluxe
Post Top

05
07
10
15
17

50W
70W
100W
150W
175W

S HPS
M MH

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor
CA CWA Autotransformer

120
208
240
277
480
MT1
MT8
MT2
MT7

120V
208V
240V
277V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V

Distribution
R2
R3
R5
RV

Type II
Type III11
Type V2,11
Type V3.11

Optics
AY Acrylic*
PY Polycarbonate*
FC Full Cutoff12

Refer to ballast matrix on


page 100 for compatibility.

*Refer to optical matrix


below for compatibility

Options
Paint4
(blank)
GY
WH
BZ

Black (standard)
Gray
White
Bronze

Lamp
LC
LD

Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated

Starter6
(blank) Open Board (standard)
EC Encapsulated Plug-in11
OP Open Plug-in11

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Position
T3 3 Wire Operation (L1, N, L2 Position)11 Misc.
PC
Listing11
UL UL Listed
SH
SS
CS CSA Certified
5H
NL
Fusing10
HS
SF Single Fuse (120, 277, 347V)
TL
DF Double Fuse (208, 240, 480V)
LDR
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle5

1
2
3
4
5
6
7

Photocontrol Included per


Voltage Specified5
Shorting Cap5
Stainless Steel Hardware
50 Hertz Ballast Cycle7
NEMA Label (2x2)
House Side Shield9
Tool-less Entry
Ladder Rest13

8
9
10
11
12
13

Voids UL/CSA Listing


Four white panels
Four clear panels
Other colors available, please contact your local
American Electric Lighting representative
PC, SH not available with NR option
HPS only
Limited availability, please contact your local
American Electric Lighting representative
T3 option only available with 240, 480, DT2, DT4, MT2
Acrylic only
Not available in MT voltage
Not available on FC version
Nighttime FriendlyTM optic
Ships with unit, field installed

Optic Distribution
05S
07S
10S
15S
07M
10M
15M
17M

R2 AY R3 AY R5 AY RV AY R2 PY
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

R3 PY R5 PY RV PY R2 FC
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Product Guide

63

American Revolution
Series 247 and 247 Cutoff
50-150W HPS, 70-175W MH

P R O D U C T

O V E R V I E W

Features:

SERIES 247

Die-cast aluminum housing and hood for long-life performance


Die-cast trigger latch (TL) option available for easy access to internal
components
Optical assembly designed for maximum performance
Hinged hood and captive screw provision afford quick, easy access to
electrical and optical area for relamping or servicing
Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or
3" O.D.
E39 mogul base socket standard
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31 (regular only), C136.16
(FC only)
Suitable for -30C MH & / -40C HPS
Full cutoff version is Nighttime FriendlyTM
SERIES 247 CUTOFF

Applications:
Streetscapes
Walkways
Pathways
Parks

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

Series 247
247 10S RN 120 R3 AY
247 15S RN 120 R3 AY
247 10S RN 120 R5 AY
247 15S RN 120 R5 AY
Series 247 Cutoff
247 10S RN 120 R2 FC TL
247 10M XN MT1 R2 FC TL

64

Product Guide

Effective Projected Area (EPA)


The EPA for the American Revolution Series 247 is 1.6 sq. ft.
Approx. Wt. = 36 lbs.

For photometric information, visit our website,


www.americanelectriclighting.com

American Revolution
Series 247 and 247 Cutoff
50-150W HPS, 70-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: 2 4 7 1 5 S R N 1 2 0 R 5 A Y E C

Wattage / Source

Series
247 American
Revolution
Post Top

05
07
10
15
17

50W
70W
100W
150W
175W

S HPS
M MH

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor
CA CWA Autotransformer
CT CWI Autotransformer

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Refer to ballast matrix on


page 101 for compatibility.

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V

Distribution
R2
R3
R5
RV

Type II
Type III11
Type V2,11
Type V3.11

Optics
AY Acrylic*
PY Polycarbonate*
FC Full Cutoff12

*Refer to optical matrix


below for compatibility

Options
Paint4
(blank)
GY
WH
BZ

Black (standard)
Gray
White
Bronze

Lamp
LC
LD

Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated

Starter6
(blank) Open Board (standard)
EC Encapsulated Plug-in11
OP Open Plug-in11

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Position
T3 3 Wire Operation (L1, N, L2 Position)11 Misc.
PC
Listing11
UL UL Listed
SH
SS
CS CSA Certified
5H
NL
Fusing10
HS
SF Single Fuse (120, 277, 347V)
TL
DF Double Fuse (208, 240, 480V)
LDR
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle5

1
2
3
4
5
6
7

Photocontrol Included per


Voltage Specified5
Shorting Cap5
Stainless Steel Hardware
50 Hertz Ballast Cycle7
NEMA Label (2x2)
House Side Shield9
Tool-less Entry
Ladder Rest13

8
9
10
11
12
13

Voids UL/CSA Listing


Four white panels
Four clear panels
Other colors available, please contact your local
American Electric Lighting representative
PC, SH not available with NR option
HPS only
Limited availability, please contact your local
American Electric Lighting representative
T3 option only available with 240, 480, DT2, DT4, MT2
Acrylic only
Not available in MT, TT, DT voltages
Not available on FC version
Nighttime FriendlyTM optic
Ships with unit, field installed

Optic Distribution
05S
07S
10S
15S
07M
10M
15M
17M

R2 AY R3 AY R5 AY RV AY R2 PY
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

R3 PY R5 PY RV PY R2 FC
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Product Guide

65

Georgian
Series GRP
50-150W HPS, 70-175W MH

P R O D U C T

O V E R V I E W

Features:
Two (2) piece cast aluminum housing
Castings are hinged and open with a simple 1/4 turn thumb screw for easy
maintenance
Choice of two (2) mounting arrangements: side entry or post top
Lenses are sealed with neoprene gaskets to prevent ingress of dirt or
moisture in luminaire. Bottom lens is sealed with a felt gasket for proper
breathing of luminaire (top entry and side entry units only)
All ballasts are mounted on a ballast plate with quick disconnect, for easy
replacement
All exposed screws are stainless steel
Cast aluminum slipfitter accepts 3 to 3-1/2 O.D. X 4 long tenon or pole.
Mounting hardware included
A photocell cupola is supplied when ordering the photocell receptacle
Mogul base socket
Certified by CSA and UL standards

Applications:

All electrical components warranted by American Electric Lighting's 6-year


guarantee

Residential areas
Architectural landscape lighting
Parks, walkways
Recreational areas
Commercial environments

Complies with ANSI: C136.2, C136.10, C136.15, C136.16

DIMENSIONS
POST TOP

PREFERRED SELECTION CATALOG NUMBERS


SIDE MOUNT

GRS 10S CT DT1 R2 RD SB CS EC NL PC PY


GRS 15S CT DT1 R3 RD CS EC NL PC PY
GRP 10S CT DT1 R3 RD SB CS EC NL PC CD PY
GRP 15S CT DT1 R3 RD SB CS EC PC NL PY

Effective Projected Area (EPA)


The EPA for the Georgian is 2.93 sq. ft.
Approx. Wt. = 46 lbs.

66

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Georgian
Series GRP
50-150W HPS, 70-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: G R P 1 0 S R H 1 2 0 R 3 R D P Y

GRP Post Top


GRS Side Mount
GRL Post Top w/
ladder rest

Ballast

Wattage / Source

Series
05
07
10
15
17

50W
70W
100W
150W
175W

M MH
S HPS

CA CWA Autotransformer
CT CWI Autotransformer
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor

Refer to ballast matrix on


page 102 for compatibility.

Voltage
120
208
240
277
347
480
DT1
DT2
MT1
MT2
MT7
TT3

120V
208V
240V
277V
347V
480V
Dual Tap 120/240 Wired 120
Dual Tap 120/240 Wired 240
Multi-tap Wired 120
Multi-tap Wired 240
Multi-tap Wired 277
Tri-tap Wired 347

Distribution
R2 Roadway Type II
R3 Roadway Type III
R5 Type 51

Optics
RD High Performance
Roadway Reflector
OA Open Bottom Acrylic2
CR Cone Reflector

Options
Paint
(blank)
BZ
GY
WH
SB

Black (standard)
Bronze
Gray
White
Shibui Brown

Terminal Block
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2 Position)3
Listing
(blank)
CS

UL Listing (standard)
CSA Certified

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
NR No Receptacle
Misc.
PC
SH
NL
CH
CD
CB

Photocontrol Included
Shorting Cap
NEMA Label
Decorative Chimney2
Decorative Candle2
Century Base

Notes:
1
2
3
4

Available only with OA optics


Cannot be used together with other optics
T3 option only available with 240, 480, DT2, DT4, MT2
HPS only

Side Panels
GL Glass
PY Polycarbonate
AY Acrylic
PE Pebbled Glass

Starter4
EC Encapsulated Plug-in
OP Open Plug-in

Product Guide

67

Bainbridge
Series 870
50-150W HPS,175W MH

P R O D U C T

O V E R V I E W

Features:
Architecturally complimentary design
Powdercoated, paint finish
Terminal block for ease of wiring
A variety of wattages and ballast types
Available in HPS and MH
Easy access to electrical components
Available in a variety of IES distributions
E39 mogul base socket standard
All electrical components warranted by American Electric Lightings 6-year
guarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30C MH / -40C HPS

Applications:
Office buildings
Shopping centers
Malls
Apartment/condominium complexes
Commercial developments
DIMENSIONS

16-1/2
(419)

27
(686)
37
(940)

Effective Projected Area (EPA)


The EPA for the Bainbridge Series 870 is 3.7 sq. ft.
Approx. Wt. = 28 lbs.

68

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Bainbridge
Series 870
50-150W HPS,175W MH

O R D E R I N G

I N F O R M AT I O N

Example: 8 7 0 1 0 S C A M T 1 R 3 A Y L C

Series
870

Bainbridge

Wattage / Source
05
07
10
15
17

50W
70W
100W
150W
175W

S HPS
M MH

Voltage

Ballast
CA CWA Autotransformer
RH Reactor High
Power Factor
RN Reactor Normal
Power Factor
XH High Reactance / Lag
High Power Factor
XN High Reactance / Lag
Normal Power Factor

120
208
240
277
480
DT2
MT1
MT2
MT7

120V
208V
240V
277V
480V
Dual Tap 120/240
Wired 240
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V

Refer to ballast matrix on page 102


for compatibility.

Distribution
R3 Type III1
R5 Type V1
R0 No Internal
Refractor

Optics
AY Acrylic
PY Polycarbonate
WC White
Polycarbonate

Options
Paint
(blank)
BZ

Black (standard)
Bronze

Photocontrol
(blank) None
BC Button-photocontrol

Terminal Block
Misc.
T2 Wired to L1 & L2 Positions
SS
T3 3 Wire Operation (L1, N, L2 Position)2
NL
Lamp
LC
LD

Notes:
1 Achieved with internal glass refractor
2 T3 option only available with 240, 480, DT2, DT4, MT2

Stainless Steel Hardware


NEMA Label

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Product Guide

69

Marietta
Series LMD
50-250W HPS, 50-250W MH

PP RR O
OD
DU
U CC TT O
O VV EE RR VV II EE W
W

Features:
Available in solid or clear top prismatic globe
Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Available in Semi-Cutoff IES classification
Injection-molded, high-impact acrylic or polycarbonate
Excellent uniformity, light distribution and efficiency
Maximizes pole spacing
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket for
quick access
Quick disconnect plug for easy maintenance
Easy access component door

Applications:

Photocontrol and terminal block available and located with easy access from
component door

Streetscapes
Walkways
Pathways
Parks

Uplight shield is standard


E39 mogul base socket standard
Mounts to 3 x 3 pole top tenons
DIMENSIONS

All electrical components warranted by American Electric Lighting's 6-year


guarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30C MH / -40C HPS
PREFERRED SELECTION CATALOG NUMBERS

LMD 10S RN 120 R3 PA PR


LMD 10S RN 120 R5 PA PR
LMD 10M XN MT1 R3 PA PR
LMD 10M XN MT1 R5 PA PR

Effective Projected Area (EPA)


The EPA for the Marietta Series is 2.7 sq. ft.
Approx. Wt. = 24lbs.

70

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Marietta
Series LMD
50-250W HPS, 50-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: L M D 1 7 M C A M T 1 R 5 P A P R P C

Wattage / Source

Series
LMD

Marietta

05
07
10
15
17
25

S
M

50W
70W
100W
150W
175W
250W2

Voltage

Ballast
HPS
MH

RN
RH
XN
XH
CA
CT

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI

Refer to ballast matrix on page 102


for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
DT2
TT3

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Dual Tap 120/240
Wired 240V
Tri-tap Wired 347V

Distribution
R3 Type III
R5 Type V

Options
Globe
PA
PT
PN

Prismatic Acrylic SolidTop (optical)


Prismatic Clear Top Polycarbonate
(optical)
Prismatic Clear Top Acrylic
(optical)

Paint3
(blank) Black
VG Verde Green
BZ Bronze

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc
PC
SH
SS
BD
F5
TL
US

Locking Type Photocontrol1


Shorting Cap1
Stainless Steel Fasteners (external)
Without Decorative Cage
Spike Finial5
Tool-less Entry
Uplight Shield

Notes:
1 For use with PR option
2 250W adds 3 to housing height
3 Other colors available, please contact your local
American Electric Lighting representative
4 T3 option only available with 240, 480, DT2, DT4, MT2
5 Standard with PA optic

Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operations (L1, N, L2 Position)4

Receptacle
(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle

Product Guide

71

Sumter
Series LSH
50-250W HPS, 50-250W MH

P R O D U C T

O V E R V I E W

Features:
Solid top prismatic globe
Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Available in Semi-Cutoff IES classification
Injection-molded, high-impact acrylic or polycarbonate
Excellent uniformity, light distribution and efficiency
Maximizes pole spacing
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket for
quick access
Quick disconnect plug for easy maintenance
Easy access component door

Applications:

Photocontrol and terminal block available and located with easy access from
component door

Streetscapes
Walkways
Pathways
Parks

E39 mogul base socket standard


Mounts to 3 x 3 pole top tenons
All electrical components warranted by American Electric Lighting's 6-year
guarantee
DIMENSIONS

Complies with ANSI: C136.2, C136.10, C136.15, C136.31


Suitable for -30C MH / -40C HPS

Effective Projected Area (EPA)


The EPA for the Sumter Series is 2.7 sq. ft.
Approx. Wt. = 24 lbs.

72

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Sumter
Series LSH
50-250W HPS, 50-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: L S H 1 7 M C A 1 2 0 R 5 P A P R L C P C

Wattage / Source

Series
LSH

Sumter

05
07
10
15
17
25

S
M

50W
70W
100W
150W
175W
250W1

Voltage

Ballast
HPS
MH

RN
RH
XN
XH
CA
CT

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI

Refer to ballast matrix on page 103


for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
DT2
TT3

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Dual Tap 120/240
Wired 240
Tri-tap Wired 347V

Distribution
R3 Type III
R5 Type V

Options
Globe
PP
PA

Prismatic Polycarbonate (optical)


Prismatic Acrylic (optical)

Paint
(blank) Black
VG Verde Green
BZ Bronze

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc
PC
SH
SS

Locking Type Photocontrol3


Shorting Cap3
Stainless Steel Fasteners (external)

Notes:
1 250W adds 3 to housing height
2 T3 option only available with 240, 480, DT2, DT4, MT2
3 For use with PR option

Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operations (L1, N, L2 Position)2
Receptacle
(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle

Product Guide

73

Cresthill Classic
Series LCR
50-150W HPS, 50-175W MH

P R O D U C T

O V E R V I E W

Features:
Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Globe available in stepped acrylic and polycarbonate or prismatic acrylic and
polycarbonate
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket for
quick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access from
component door
E39 mogul base socket standard
Mounts to 3 x 3 pole top tenons

Applications:

All electrical components warranted by American Electric Lighting's 6-year


guarantee

Streetscapes
Walkways
Pathways
Parks

Complies with ANSI: C136.2, C136.10, C136.15, C136.31


Suitable for -30C MH / -40C HPS

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

LCR 10S RN 120 R5 AA PR

Effective Projected Area (EPA)


The EPA for the Cresthill Classic is 1.4 sq. ft.
Approx. Wt. = 37 lbs.

74

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Cresthill Classic
Series LCR
50-150W HPS, 50-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: L C R 1 0 S R N 1 2 0 R 5 A P P R L C P R

Wattage / Source

Series
LCR

Cresthill

05
07
10
15
17

S
M

50W
70W
100W
150W
175W

Voltage

Ballast
HPS
MH

RN
RH
XN
XH
CA
CT

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI

Refer to ballast matrix on page 103


for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Dual Tap 120/240
Wired 240

Distribution
R0 No Internal
Refractor1
R3 Type III2
R5 Type V2

Options
Globe
AP
AA
PT
PN

Classic Large Clear Polycarbonate


(Non-optical)
Classic Large Clear Acrylic
(Non-optical)
Prismatic Polycarbonate (optical)
Prismatic Acrylic (optical)

Paint
(blank) Black
VG Verde Green
BZ Bronze
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operations (L1, N, L2 Position)3

Receptacle
(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc
F5
PC
SH
SS
US
9R

Finial
Locking Type Photocontrol4
Shorting Cap4
Stainless Steel Fasteners (external)
Uplight Shield5
9" Globe Neck

Notes:
1 Not available with PN or PT options
2 Achieved with internal glass refractor
except with prismatic globes
3 T3 option only available with 240, 480, DT2, DT4, MT2
4 For use with PR options
5 For use with PN and PT only

Product Guide

75

Cresthill Sphere
Series LCR
50-150W HPS, 50-175W MH

P R O D U C T

O V E R V I E W

Features:
Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Globe 22 white acrylic or clear polycarbonate
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket
for quick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access
from component door
E39 mogul base socket standard
Mounts to 3 x 3 pole top tenons
Powdercoat finish

Applications:

All electrical components warranted by American Electric Lighting's 6-year


guarantee

Streetscapes
Walkways
Pathways
Parks

Complies with ANSI: C136.2, C136.10, C136.15, C136.31


Suitable for -30C MH / -40C HPS

DIMENSIONS

Effective Projected Area (EPA)


The EPA for the Cresthill Sphere is 2.5 sq. ft.
Approx. Wt. = 22lbs.

76

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Cresthill Sphere
Series LCR
50-150W HPS, 50-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: L C R 1 0 S R N 1 2 0 R 5 S Y P R L C P C

Wattage / Source

Series
LCR

Cresthill

05
07
10
15
17

S
M

50W
70W
100W
150W
175W

Voltage

Ballast
HPS
MH

RN
RH
XN
XH
CA
CT

120
208
240
277
480
MT1
MT8
MT2
MT7
DT1

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI

Refer to ballast matrix on page 103


for compatibility.

DT2

120V
208V
240V
277V
480V
Multi-tap Wired 120V
Multi-tap Wired 208V
Multi-tap Wired 240V
Multi-tap Wired 277V
Dual Tap 120/240
Wired 120
Dual Tap 120/240
Wired 240

Distribution
R0 No Internal
Refractor
R3 Type III1
R5 Type V1

Options
Globe
SL
SY

Sphere White Polycarbonate2


Sphere White Acrylic2

Paint
(blank) Black
VG Verde Green
BZ Bronze
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operations (L1, N, L2 Position)3

Lamp
LC
LD

Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated

Photocontrol
(blank) None
PC Locking Type Photocontrol4
Misc
SH
SS
9R

1
2
3
4
5

Achieved with internal glass refractor


Available in 9R only, requires 9R housing
T3 option only available with 240, 480, DT2, DT4, MT2
For use with PR options
For 9 neck 22 diameter globe is used

Shorting Cap4
Stainless Steel Fasteners (external)
9" Globe Neck5

Receptacle
(blank) No Photocontrol Receptacle (standard)
PR Photocontrol Receptacle

Product Guide

77

Cresthill Centennial
Series LCR
50-150W HPS, 100-175W MH

P R O D U C T

O V E R V I E W

Features:
Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Acrylic or polycarbonate globe
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket
for quick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access
from component door
E39 mogul base socket standard
Mounts to 3 x 3 pole top tenons
Powdercoat finish

Applications:

All electrical components warranted by American Electric Lighting's 6-year


guarantee

Streetscapes
Walkways
Pathways
Parks

Complies with ANSI: C136.2, C136.10, C136.15, C136.31


Suitable for -30C MH / -40C HPS
DIMENSIONS

Effective Projected Area (EPA)


The EPA for the Cresthill Centennial is 1.2 sq. ft.
Approx. Wt. = 22lbs.

78

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Cresthill Centennial
Series LCR
50-150W HPS, 100-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: L C R 1 0 S R N 1 2 0 R 5 C Y P R L C P C

Wattage / Source

Series
LCR

Cresthill

05
07
10
15
17

S
M

50W
70W
100W
150W
175W

Voltage

Ballast
HPS
MH

RN
RH
XN
XH
CA
CT

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI

Refer to ballast matrix on page 103


for compatibility.

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347
Dual Tap 120/240
Wired 240

Distribution
RO No Internal
Refractor
R3 Type III1
R5 Type V1

Options
Globe
CE
CW
CY
CM

Centennial Large Clear Acrylic


(Non-optical)
Centennial Large White
Polycarbonate2
Centennial Large Clear Acrylic
Centennial Medium Clear Acrylic

Paint
(blank) Black
VG Verde Green
BZ Bronze
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operations (L1, N, L2 Position3

Receptacle
(blank) No Photocontrol Receptacle
(standard)
PR Photocontrol Rseceptacle
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc
PC
SH
SS
9R

Twist-off Photocontrol4
Shorting Cap4
Stainless Steel Fasteners (external)
9" Globe Neck

Notes:
1
2
3
4

Achieved with internal glass refractor


For use with 9R option only, requires 9R housing
T3 option only available with 240, 480, DT2, DT4, MT2
For use with PR options

Product Guide

79

Cresthill Glass
Series LCR
50-250W HPS, 50-250W MH

P R O D U C T

O V E R V I E W

Features:
Interchangeable base with a wide variety of globes
Symmetric or Asymmetric distribution
Prismatic glass globe
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket for
quick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access from
component door
E39 mogul base socket standard
Mounts to 3 x 3 pole top tenons
Powdercoat finish

Applications:

All electrical components warranted by American Electric Lighting's 6-year


guarantee

Streetscapes
Walkways
Pathways
Parks

Complies with ANSI: C136.2, C136.10, C136.15, C136.31


Suitable for -30C MH / -40C HPS
DIMENSIONS

Effective Projected Area (EPA)


The EPA for the Cresthill Glass is 1.4 sq. ft.
Approx. Wt. = 37lbs.

80

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Cresthill Glass
Series LCR
50-250W HPS, 50-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: L C R 1 0 S R N 1 2 0 R 5 P G P R L C P C

Wattage / Source

Series
LCR

Cresthill

05
07
10
15
17
25

S
M

50W
70W
100W
150W
175W
250W1

Voltage

Ballast
HPS
MH

RN
RH
XN
XH
CA
CT

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI

Refer to ballast matrix on page 104


for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347
Dual Tap 120/240
Wired 240

Distribution
R3 Type III
R5 Type V

Options
Globe
PG

Prismatic Glass

Paint
(blank) Black
VG Verde Green
BZ Bronze
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operations (L1, N, L2 Position)2

Notes:

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc
PC
SH
SS
F5

Locking Type Photocontrol3


Shorting Cap3
Stainless Steel Fasteners (external)
Finial

1 250 W adds 3 to cast housing height


2 T3 option only available with 240, 480, DT2, DT4, MT2
3 For use with PR options

Receptacle
(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle

Product Guide

81

Lexington
Series LLX
50-150W HPS, 100-175W MH

P R O D U C T

O V E R V I E W

Features:
Available with or without spikes
Interchangeable base with a wide variety of lenses
Symmetric or Asymmetric distribution
Decorative spike finial standard
Rugged cast-aluminum housing
Lens available in acrylic, polycarbonate or clear glass
Base and optical ship separately
HPS units standard with encapsulated starter that is located at the socket for
quick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access from
component door

Applications:

E39 mogul base socket standard

Streetscapes
Walkways
Pathways
Parks

Mounts to 3 x 3 pole top tenons


All electrical components warranted by American Electric Lighting's 6-year
guarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
DIMENSIONS

Suitable for -30C MH / -40C HPS

Effective Projected Area (EPA)


The EPA for the Lexington is 3.1 sq. ft.
Approx. Wt. = 33 lbs.

82

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Lexington
Series LLX
50-150W HPS, 100-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: L L X 1 0 S R N 1 2 0 R 5 A Y P R L C P C

Series
LLX

Lexington

Wattage / Source
05
07
10
15
17

S
M

50W
70W
100W
150W
175W

Voltage

Ballast
HPS
MH

RN
RH
XN
XH
CA
CT

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI

Refer to ballast matrix on page 104


for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Dual Tap 120/240
Wired 240

Distribution
R0 No Internal
Refractor
R3 Type III1
R5 Type V1

Options
Globe
AY
PY
GL

Acrylic
Polycarbonate
Glass

Paint
(blank) Black
VG Verde Green
BZ Bronze
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operations (L1, N, L2 Position)2

Receptacle
(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc
PC
SH
SS
NS

Locking Type Photocontrol3


Shorting Cap3
Stainless Steel Fasteners (external)
No Spikes on LLX Housing

Notes:
1 Achieved with internal glass refractor
2 T3 option only available with 240, 480, DT2, DT4, MT2
3 For use with PR option

Product Guide

83

Branson
Series LBR
50-150W HPS, 50-175W MH

P R O D U C T

O V E R V I E W

Features:
Ornamental aluminum canopy top
Interchangeable base with a variety of globes
Symmetric or Asymmetric distribution
Base and optical ship separately
Powdercoat finish
HPS units standard with encapsulated starter that is located at the socket for
quick access
Quick disconnect plug for easy maintenance
Easy access component door
Photocontrol and terminal block available and located with easy access from
component door
E39 mogul base lamp holder standard
Mounts to 3 x 3 pole top tenons

Applications:

Available in stippled acrylic or polycarbonate globes

Streetscapes
Walkways
Pathways
Parks

All electrical components warranted by American Electric Lighting's 6-year


guarantee
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Suitable for -30C MH / -40C HPS

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

LBR 10S RN 120 R3 AY PR


LBR 10S RN 120 R5 AY PR

13
(330)

38
(965)

3-1/4
(83)

Effective Projected Area (EPA)


The EPA for the Branson is 2.3 sq. ft.
Approx. Wt. = 22 lbs.

84

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Branson
Series LBR
50-150W HPS, 50-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: L B R 1 5 S C A M T 1 R 5 P Y L C

Series
LBR

Branson

Wattage / Source
05
07
10
15
17

S
M

50W
70W
100W
150W
175W

Voltage

Ballast
HPS
MH

RN
RH
XN
XH
CA
CT

Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI

Refer to ballast matrix on page 104


for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Dual Tap 120/240
Wired 240

Distribution
RO No Internal
Refractor
R3 Type III1
R5 Type V1

Options
Globe
AY
PY

Acrylic
Polycarbonate

Paint2
(blank) Black
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operations (L1, N, L2 Position)3

Receptacle
(blank) No Photocontrol Receptacle (std)
PR Photocontrol Receptacle
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc
PC
SH
SS

Locking Type Photocontrol4


Shorting Cap4
Stainless Steel Fasteners (external)

Notes:
1 Achieved with internal glass refractor except with
prismatic globes
2 Other colors available, please contact your local
American Electric Lighting representative
3 T3 option only available with 240, 480, DT2, DT4, MT2
4 For use with PR option

Product Guide

85

Contempo
Series 245
50-400W HPS, 70-400 MH

P R O D U C T

O V E R V I E W

Features:
Die-cast aluminum housing and spun aluminum hood for long-life performance
Optical assembly designed for maximum performance
Multi-gasketing to provide weatherproof protection of optical assembly for full
illumination performance
Hinged hood and captive screw latching provision afford quick, easy access to
electrical and optical area for relamping or servicing
Available with two different style hoods and an added scroll option for a more
decorative look
Cone mounting fitter with three set screws allows secure installation to pole
sizes 2-3/8" or 3" O.D.
Refractor available in tempered glass, acrylic and polycarbonate
Available in a variety of IES light distributions patterns
E39 mogul base socket standard

Applications:

All electrical components warranted by American Electric Lighting's 6-year


guarantee

Streetscapes
Walkways
Pathways
Parks

Complies with ANSI: C136.2, C136.10, C136.15, C136.16


Suitable for -30C MH / -40C HPS

PREFERRED SELECTION CATALOG NUMBERS

245 10S RN 120 R5 AY


245 15S RN 120 R5 AY
245 25S CA MT1 R5 GL
245 15S CA MT1 R5 AY
DIMENSIONS

DIMENSIONS

SCROLL DESIGN OPTION

Effective Projected Area (EPA)


The EPA for the Contempo Series 245 is 1.3 sq. ft.
Approx. Wt. = 32 lbs.

86

Product Guide

Effective Projected Area (EPA)


The EPA for the Decorative Scroll Option is 1.8 sq. ft.
Approx. Wt. = 32 lbs.

For photometric information, visit our website,


www.americanelectriclighting.com

Contempo
Series 245
50-400W HPS, 70-400W MH

O R D E R I N G I N F O R M AT I O N
O R D E R I N G I N F O R M AT I O N
Example: 2 4 5 1 0 S R N 1 2 0 R 3 G L S D P C

Wattage / Source

Series
245 Contempo
Post Top

05
07
10
13
14
15
17
25
40

RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor
CA CWA Autotransformer
CT CWI Autotransformer
SC SCWA
MR Mag Reg (3 coil)

50W
S HPS
70W
M MH
100W
100/150 Wired 100
100/150 Wired 150
150W
175W
250W
400W

Distribution

Voltage

Ballast
120
208
240
277
480
MT1
MT2
MT7
TT3
DT2
5T4

120V
208V
240V
277V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240 wired 240V
5-tap Wired 480V7

R2 Type II
R3 Type III
R5 Type V

Optics
GL Glass
AY Acrylic6
PY Polycarbonate6

Refer to ballast matrix on


page 105 for compatibility.

Refer to optical matrix


below for
compatibility
Options
Paint1
(blank)
BK
WH
BZ

Gray (standard)
Black
White
Bronze

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2 Position)8
Listing
UL
CS

UL Listed
CSA Certified

Fusing2
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter4
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in

Hood Style (see line art)


(blank) Style A
SD Style D
Misc.
PC
SS
5H
NL
DD
SH

Photocontrol Included per


Voltage Specified3
Stainless Steel Hardware
50 Hertz Ballast Cycle5
NEMA Label
Decorative Scroll Design9
Shorting Cap3

Notes:
1 Other colors available, please contact your local
American Electric Lighting representative
2 Voids UL/CSA not available in MT, TT, DT,
voltages
3 PC, SH not available with NR option
4 Available in HPS only
5 Limited availability, please contact your local
American Electric Lighting representative
6 Available in 250W maximum
7 Available in 250W and 400W HPS and MH
8 T3 option only available with 240, 480, DT2, DT4, MT2
9 Scroll color must be specified

Optic Distribution
05S
07S
10S
15S
20S
25S
31S
40S
17M
25M
40M

R2 AY R3 AY R5 AY R2 PY R3 PY R5 PY
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-

R2 GL
N
N
N
N
N
N
N
N
N
N
N

R3 GL R5 GL
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Product Guide

87

TwistPack
Series TWT
50-250W HPS, 70-250W MH

P R O D U C T

O V E R V I E W

Features:
Unique locking type feature with locking screw that allows easy removal of
optical assembly from slipfitter casting
Slipfitter casting houses ballast. It will fit over a post having top diameter of
3-1/2 (4O.D.) or 3 (3-1/2O.D.)
Slipfitter casting is secured to post by three Allen-head locking screws
Some components of the ballast (e.g. capacitors and/or ignitors) depending on
wattage or type, may extend below the slipfitter casting and may have to fit in
the top of the pole
Aluminum hood covers are either 24 or 28 diameter
Refractors offered in IES Type II, and V distributions
Available in polycarbonate or acrylic refractors
Mogul base socket
Natural aluminum finish is standard, other colors available
NEMA type photocell receptacle is standard

Applications:

CSA certified option available


All electrical components warranted by American Electric Lighting's 6-year
guarantee

Shopping malls
Parks
Campuses
Residential streets
Condominiums
Walkways

Complies with ANSI: C136.2, C136.10, C136.15, C136.16

DIMENSIONS
H4 HOOD

PREFERRED SELECTION CATALOG NUMBERS


H8 HOOD

Effective Projected Area (EPA)


The EPA for the TwistPack H4 Hood is 1.40 sq. ft.
The EPA for the TwistPack H8 Hood is 1.28 sq. ft.
Approx. Wt. = 41 lbs.

88

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

TWT 10S RN 120 R5 AY H8 CS NR EC


TWT 15S RN 120 R5 AY H8 CS NR EC

TwistPack
Series TWT
50-250W HPS, 70-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: T W T 1 5 S R N 1 2 0 R 5 A Y H 8

Wattage / Source

Series
TWT TwistPack

05
07
10
15
17
25

50W
70W
100W
150W
175W
250W

Voltage

Ballast

M Metal Halide
S HPS

CA CWA
Autotransformer
CT CWI
Autotransformer
RH Reactor High
Power Factor
RN Reactor Normal
Power Factor
XH High Reactance/Lag
High Power Factor
XN High Reactance/Lag
Normal Power Factor

120
208
240
277
347
480
DT2
MT1
MT2
MT7
5T4

R2
120V
R5
208V
240V
277V
347V
480V
Dual Tap 120/240 Wired 240
Multi-tap Wired 120
Multi-tap Wired 240
Multi-tap Wired 277
5-tap Wired 4806

Distribution
Roadway Type II
Type V
Optics
AY Acrylic
PY Polycarbonate1
Hood
H4
H8

24 hood2
28 hood

Refer to ballast matrix on


page 105 for compatibility.

Options
Paint
UP
BK
BZ
GY
WH

Unpainted (standard)
Black
Bronze
Gray
White

Lamp
LC
LD

Starter5
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in

Terminal Block
Misc.
T2 Wired to L1 & L2 Positions
PC
T3 3 Wire Operation (L1, N, L2 Position)4
Listing
CS

CSA Certified

Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated

NL
SH
SS

1
2
3
4
5
6

PY available in HPS only


H4 available in 175W and below
PC and SH not available with NR option
T3 option only available with 240, 480, DT2, DT4, MT2
HPS only
Available in 250W

Photocontrol Included per


Voltage Specified3
NEMA Label
Shorting Cap3
Stainless Steel Hardware

Supply Wire
P Pre-wired to Terminal Block
S Supply Wire Included in Carton
See page 118.
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle3

Product Guide

89

Decorative Poles
Chadsworth Series
Cast Aluminum Posts Extruded Shaft

P R O D U C T

O V E R V I E W

Features:
INSTALLATION The post shall be provided with four, hot-dip
galvanized L-type anchor bolts to be installed on an 10" - 12"
diameter bolt circle. A door shall be provided in the base for
anchorage and wiring access. A grounding screw shall be
provided inside the base opposite the door.
MATERIALS The base shall be heavy wall, copper free, cast
aluminum produced from certified ASTM 356.1 ingot per ASTM
B-179-95a or ASTM B26-95. The straight shafts shall be extruded
from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The
tapered shaft shall be extruded from aluminum, ASTM 6063 alloy,
spun to a tapered shape, then heat treated to a T6 temper. All
hardware shall be tamper resistant stainless steel. Anchor bolts to
be completely hot-dip galvanized.
CONSTRUCTION The shaft shall be double welded to the base
casting and shipped as one piece for maximum structural integrity.
The shaft shall be circumferentially welded inside the base casting
at the top of the access door, and externally where the shaft exits
the base. All exposed welds below 8 shall be ground smooth. All
welding shall be per ANSI/AWS D1.2-90. All welders shall be
certified per Section 5 of ANSI/AWS D1.2-90.
DIMENSIONS The post shall be 8- 16 in height (depending on
customer selection) with a 16" diameter base. The shaft diameter
varies depending on shaft type selected. (See page 91.) At the top
of the post, an integral 3" O.D. x 3" tenon with a transitional donut
shall be provided for luminaire mounting.

Applications:
Streetscapes
Walkways
Pathways
Parks

90

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Decorative Poles
Chadsworth Series
Cast Aluminum Posts Extruded Shaft

O R D E R I N G

I N F O R M AT I O N

Example: P X C H 1 6 1 2 S 5 A N B K A E L

AEL
Series

Height

PX CH16 Chadsworth

8
10
12
14
161

Shaft Type
S4
S5
F4
F5
T4
T5

Smooth 4"
Smooth 5"
Fluted 4"
Fluted 5"
Tapered 4"-3"
Tapered 5"-3"

Finish2
ANBK
ANDB
ANDG
CM
CS

Black
Bronze
Dark Green
Custom Match
Custom Select
RAL colors

Options

Manufacturing Code

_________ Receptacles
_________ Banner Arms
_________ Flagpole Holders
_________ Signage

AEL

(See Accessories section or contact


your local AEL representative.)

Notes:
1 16' height not available for S4, F4, or T4 (any
4") Shaft Type
2 For finish specifications and color options,
please contact your local American Electric
Lighting representative

DIMENSIONS

Product Guide

91

Decorative Poles
New Albany Series
Cast Aluminum Posts Extruded Shaft

P R O D U C T

O V E R V I E W

Features:
INSTALLATION The post shall be provided with four, hot-dip
galvanized L-type anchor bolts to be installed on an 12" diameter bolt
circle. A door shall be provided in the base for anchorage and wiring
access. A grounding screw shall be provided inside the base opposite
the door.
MATERIALS The base shall be heavy wall, copper free, cast aluminum
produced from certified ASTM 356.1 ingot per ASTM B-179-95a or
ASTM B26-95. The straight shafts shall be extruded from aluminum,
ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall
be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape,
then heat treated to a T6 temper. All hardware shall be tamper
resistant stainless steel. Anchor bolts to be completely hot-dip
galvanized.
Smooth

Fluted

CONSTRUCTION The shaft shall be double welded to the base casting


and shipped as one piece for maximum structural integrity. The shaft
shall be circumferentially welded inside the base casting at the top of
the access door, and externally where the shaft exits the base. All
exposed welds below 8 shall be ground smooth. All welding shall be
per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of
ANSI/AWS D1.2-90.
DIMENSIONS The post shall be 8- 16 in height (depending on
customer selection) with a 16" diameter base. The shaft diameter
varies depending on shaft type selected. (See page 93.) At the top of
the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be
provided for luminaire mounting.

Tapered

Applications:
Streetscapes
Walkways
Pathways
Parks

92

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Decorative Poles
New Albany Series
Cast Aluminum Posts Extruded Shaft

O R D E R I N G

I N F O R M AT I O N

Example: P X N Y 1 7 1 2 S 5 A N B K A E L

AEL
Series

Height

PX NY17 New Albany

8
10
12
14
161

Finish2

Shaft Type
S4
S5
F4
F5
T4
T5

Smooth 4"
Smooth 5"
Fluted 4"
Fluted 5"
Tapered 4"-3"
Tapered 5"-3"

ANBK
ANDB
ANDG
CM
CS

Black
Bronze
Dark Green
Custom Match
Custom Select
RAL colors

Options

Manufacturing Code

_________ Receptacles
_________ Banner Arms
_________ Flagpole Holders
_________ Signage
(See Accessories section or contact
your local AEL representative.)

Notes:
1 16' height not available for S4, F4, or T4 (any
4") Shaft Type.
2 For finish specifications and color options,
please contact your local American Electric
Lighting representative.

DIMENSIONS

Product Guide

93

Decorative Poles
Statesboro Series
Cast Aluminum Posts Extruded Shaft

P R O D U C T

O V E R V I E W

Features:
INSTALLATION The post shall be provided with four, hot-dip
galvanized L-type anchor bolts to be installed on an 9.5" diameter
bolt circle. A door shall be provided in the base for anchorage and
wiring access. A grounding screw shall be provided inside the base
opposite the door.
MATERIALS The base shall be heavy wall, copper free, cast
aluminum produced from certified ASTM 356.1 ingot per ASTM
B-179-95a or ASTM B26-95. The straight shafts shall be extruded
from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The
tapered shaft shall be extruded from aluminum, ASTM 6063 alloy,
spun to a tapered shape, then heat treated to a T6 temper. All
hardware shall be tamper resistant stainless steel. Anchor bolts to
be completely hot-dip galvanized.

Applications:
Streetscapes
Walkways
Pathways
Parks

94

Product Guide

CONSTRUCTION The shaft shall be double welded to the base


casting and shipped as one piece for maximum structural integrity.
The shaft shall be circumferentially welded inside the base casting
at the top of the access door, and externally where the shaft exits
the base. All exposed welds below 8 shall be ground smooth. All
welding shall be per ANSI/AWS D1.2-90. All welders shall be
certified per Section 5 of ANSI/AWS D1.2-90.
DIMENSIONS The post shall be 8- 14 in height (depending on
customer selection) with a 16" diameter base. The shaft diameter
varies depending on shaft type selected. (See page 95.) At the top of
the post, an integral 3" O.D. x 3" tenon with a transitional donut shall
be provided for luminaire mounting. .

For photometric information, visit our website,


www.americanelectriclighting.com

Decorative Poles
Statesboro Series
Cast Aluminum Posts Extruded Shaft

O R D E R I N G

I N F O R M AT I O N

Example: P X S 9 1 2 S 4 A N B K A E L

AEL
Series

Height

PX S9 Statesboro

8
10
12
14

Finish2

Shaft Type
S4 Smooth 4"
F4 Fluted 4"
T4 Tapered 4"-3"

ANBK
ANDB
ANDG
CM
CS

Black
Bronze
Dark Green
Custom Match
Custom Select
RAL colors

Options

Manufacturing Code

_________ Receptacles
_________ Banner Arms
_________ Flagpole Holders
_________ Signage
(See Accessories section or contact
your local AEL representative.)

DIMENSIONS

Product Guide

95

Decorative Poles
Waycross Series
Cast Aluminum Posts Extruded Shaft

P R O D U C T

O V E R V I E W

Features:
INSTALLATION The post shall be provided with four, hot-dip
galvanized L-type anchor bolts to be installed on an 12" diameter bolt
circle. A door shall be provided in the base for anchorage and wiring
access. A grounding screw shall be provided inside the base opposite
the door.
MATERIALS The base shall be heavy wall, copper free, cast aluminum
produced from certified ASTM 356.1 ingot per
ASTM B-179-95a or ASTM B26-95. The straight shafts shall be
extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper.
The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy,
spun to a tapered shape, then heat treated to a T6 temper. All
hardware shall be tamper resistant stainless steel. Anchor bolts to be
completely hot-dip galvanized.
CONSTRUCTION The shaft shall be double welded to the base casting
and shipped as one piece for maximum structural integrity. The shaft
shall be circumferentially welded inside the base casting at the top of
the access door, and externally where the shaft exits the base. All
exposed welds below 8 shall be ground smooth. All welding shall be
per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of
ANSI/AWS D1.2-90.
DIMENSIONS The post shall be 8- 16 in height (depending on
customer selection) with a 16" diameter base. The shaft diameter
varies depending on shaft type selected. (See page 97.) At the top of
the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be
provided for luminaire mounting. .

Applications:
Streetscapes
Walkways
Pathways
Parks

96

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Decorative Poles
Waycross Series
Cast Aluminum Posts Extruded Shaft

O R D E R I N G

I N F O R M AT I O N

Example: P X W 1 7 1 2 S 5 A N B K A E L

AEL
Series
PX W17 Waycross

8
10
12
14
161

Finish2

Shaft Type

Height
S4
S5
F4
F5
T4
T5

Smooth 4"
Smooth 5"
Fluted 4"
Fluted 5"
Tapered 4"-3"
Tapered 5"-3"

ANBK
ANDB
ANDG
CM
CS

Black
Bronze
Dark Green
Custom Match
Custom Select
RAL colors

Options

Manufacturing Code

_________ Receptacles
_________ Banner Arms
_________ Flagpole Holders
_________ Signage

AEL

(See Accessories section or contact


your local AEL representative.)

Notes:
1 16' height not available for S4, F4, or T4 (any
4") Shaft Type.
2 For finish specifications and color options,
please contact your local American Electric
Lighting representative.

DIMENSIONS

Product Guide

97

Decorative Poles
Weatherproof Receptacles
External, Post Shaft Location

P R O D U C T

O V E R V I E W

Features:
INSTALLATION External receptacles are typically installed above pedestrian level for special event uses and decorative seasonal lighting.
CONSTRUCTION Ground fault circuit interrupter receptacles. Test/Reset buttons on face of receptacles. All cast aluminum covers,
not plastic. (Paintable to match post color). Weatherproof While-in-Use covers in two sizes.

Receptacle with Wet Location While Closed Cover

Catalog part # FG-S

SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit


interrupter duplex receptacle shall be mounted in the post.
The receptacle shall be UL Listed according to E-48380 and
UL 943 Class A and UL 498. The receptacle shall have a cast
aluminum, UL Listed cover that is suitable for wet locations
while not in use. The receptacle and cover shall mount to an
outlet opening, in the post shaft, with a gasket and stainless
steel screws.

Receptacle with Small, In-Use Wet Location Cover

Catalog part # FGIUS-S

SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit


interrupter duplex receptacle shall be mounted in the post.
The receptacle shall be UL Listed according to E-48380 and
UL 943 Class A and UL 498. The receptacle shall have a cast
aluminum, lockable, UL Listed cover that is suitable for wet
locations while in use and complies with NEC Article 41057(b). The cover shall accept most common cord sets up to
3/8 diameter (14/3). The receptacle and cover shall mount to
an outlet opening, in the post shaft, with a gasket and
stainless steel screws.

Receptacle with Large, In-Use Wet Location Cover


Catalog part # FGIUL-S

SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit


interrupter duplex receptacle shall be mounted in the post.
The receptacle shall be UL Listed according to E-48380 and
UL 943 Class A and UL 498. The receptacle shall have a cast
aluminum, lockable, UL Listed cover that is suitable for wet
locations while in use and complies with NEC Article 41057(b). The cover shall accept most common cord sets up to
1/2 diameter (12/3). The receptacle and cover shall mount to
an outlet opening, in the post shaft, with a gasket and
stainless steel screws.

98

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Decorative Poles
Weatherproof Receptacles
External, Post Shaft Location

P R O D U C T

O V E R V I E W

Features:
INSTALLATION Internal receptacles are typically installed for use by authorized personnel for special events and owner maintenance purposes.
CONSTRUCTION Ground fault circuit interrupter receptacles. Test and reset buttons on face of receptacles. All cast aluminum covers,
not plastic.

Receptacle with Weatherproof Box and Cover


Catalog part # RB/GFI/WPC
SPECIFICATIONS A 20amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted inside the post base, facing toward the
access door. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall be mounted in a cast
aluminum box and cover that is suitable for wet locations while not in use. The receptacle and cover shall mount to a outlet box with a gasket
and stainless steel screws.

Product Guide

99

Decorative and Post Top Lighting


B A L L A S T

M AT R I C E S

Valiant
Watts
05S
07S
07M
10S
10M
13S
15S
15M
17M
20S
25S
25M

120
RN, RH
CA, CT, RH, RN
XH, XN
RN, RH, CA, CT
XH, XN, CA
RN, RH
RN, RH, CA, CT
XN, XH
CA
CA
XN, XH, CA
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
RN, RH, CA
XN, XH, CA
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
CA, CT
CA, CT

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
-

480
XN, XH
XN, XH, CA
XN, XH, CA
CA
CA
CA
CA

DT2
XN, XH, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
XN, XH
CA
CA
XN, XH, CA
CA

MT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA

Valiant continued
Watts
05S
07S
07M
10S
10M
13S
15S
15M
17M
20S
25S
25M

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA

American Revolution Deluxe Series


Watts
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M

120
RH, RN
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XH, XN, CA
RH, RN
RH, RN
RN, RH, CA, CT
XN, XH
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

480
XN, XH
XN, XH, CA
XN, XH, CA
CA

American Revolution Deluxe Series continued


Watts
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M

100

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

Product Guide

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

For photometric information, visit our website,


www.americanelectriclighting.com

DT2
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
XN, XH
CA

MT1
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
CA

Decorative and Post Top Lighting


B A L L A S T

M AT R I C E S

American Revolution Series 247


Watts
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M

120
RH, RN
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XH, XN, CA
RH, RN
RH, RN
RN, RH, CA, CT
XN, XH
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

480
XN, XH
XN, XH, CA
XN, XH, CA
CA

DT2
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
XN, XH
CA

MT1
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

480
XN, XH
XN, XH, CA
XN, XH, CA
CA

DT2
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
XN, XH
CA

MT1
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
XH, XN, CA, CT
XN, XH
CA

American Revolution Series 247 continued


Watts
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

American Revolution Cutoff Series 247


Watts
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M

120
RH, RN
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XH, XN, CA
RH, RN
RH, RN
RN, RH, CA, CT
XN, XH
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

American Revolution Cutoff Series 247 continued


Watts
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

Product Guide

101

Decorative and Post Top Lighting


B A L L A S T

M AT R I C E S

Georgian Series GRP


Wattage
05S
07S
07M
10S
10M
15S
15M
17M

120
RN,RH
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XN, XH, CA
RN, RH, CA, CT
XN, XH
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

480
XN, XH
XN, XH, CA
XN, XH, CA
CA

DT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA

MT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

Georgian Series GRP continued


Wattage
05S
07S
07M
10S
10M
15S
15M
17M

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

Bainbridge Series 870


Watts
05S
07S
10S
15S
17M

120
RN
RN, RH, CA, CT
RN, RH, CA, CT
RN, RH, CA, CT
CA

208
XN, XH, CA, CT
XN, XH, CA, CT
XN, XH, CA, CT
CA

240
XN, XH, CA, CT
XN, XH, CA, CT
XN, XH, CA, CT
CA

277
XN, XH, CA
XN, XH, CA, CT
XN, XH, CA, CT
CA

480
CA
CA
CA
CA

DT2
XN, XH, CA, CT
N, XH, CA, CT
XN, XH, CA, CT
-

MT1
CA, CT
CA, CT
CA, CT
-

MT2
CA, CT
CA, CT
CA, CT
CA

MT7
CA, CT
CA, CT
CA, CT
CA

Marietta Series LMD


Wattage
05S
07S
07M
10S
10M
15S
15M
17M
25S
25M

120
RN,RH
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XN, XH, CA
RN, RH, CA, CT
XN, XH
CA
XN, XH, CA
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
XN, XH, CA
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
-

480
XN, XH
XN, XH, CA
XN, XH, CA
CA
CA
CA

Marietta Series LMD continued


Wattage
05S
07S
07M
10S
10M
15S
15M
17M
25S
25M

102

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

Product Guide

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA, CT
CA, CT

For photometric information, visit our website,


www.americanelectriclighting.com

DT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA
XN, XH, CA
CA

MT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

Decorative and Post Top Lighting


B A L L A S T

M AT R I C E S

Sumter Series LSH


Wattage
05S
07S
07M
10S
10M
15S
15M
17M
25S
25M

120
RN,RH
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XN, XH, CA
RN, RH, CA, CT
XN, XH
CA
XN, XH, CA
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
XN, XH, CA
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
-

480
XN, XH
XN, XH, CA
XN, XH, CA
CA
CA
CA

DT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA
XN, XH, CA
CA

MT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

480
XN, XH
XN, XH, CA
XN, XH, CA
CA

DT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA

MT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

Sumter Series LSH continued


Wattage
05S
07S
07M
10S
10M
15S
15M
17M
25S
25M

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA, CT
CA, CT

Cresthill Series LCR - Classic, Sphere and Centennial


Wattage
05S
07S
07M
10S
10M
15S
15M
17M

120
RN,RH
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XN, XH, CA
RN, RH, CA, CT
XN, XH
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

Cresthill Series LCR - Classic, Sphere and Centennial continued


Wattage
05S
07S
07M
10S
10M
15S
15M
17M

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

Product Guide

103

Decorative and Post Top Lighting


B A L L A S T

M AT R I C E S

Cresthill Series LCR - Glass


Wattage
05S
07S
07M
10S
10M
15S
15M
17M
25S
25M

120
RN,RH
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XN, XH, CA
RN, RH, CA, CT
XN, XH
CA
XN, XH, CA
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
XN, XH, CA
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
-

480
XN, XH
XN, XH, CA
XN, XH, CA
CA
CA
CA

DT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA
XN, XH, CA
CA

MT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

Cresthill Series LCR - Glass continued


Wattage
05S
07S
07M
10S
10M
15S
15M
17M
25S
25M

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA, CT
CA, CT

Lexington LLX
Watts
120
208
05S
RH,RN
07S
RN, RH, CA, CT XN, XH, CA, CT
07M
XN, XH
XN, XH
10S
RN, RH, CA, CT XN, XH, CA, CT
10M
XN, XH, CA
XN, XH
15S
RH, RN, CA, CT XN, XH, CA, CT
15M
XN, XH
XN, XH
17M
CA
CA

240
277
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH
XN, XH
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
CA
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

480
XN, XH
XN, XH, CA
XN, XH, CA
CA

DT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA

MT1
MT2
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
CA
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

Branson LBR
Watts
120
208
05S
RH,RN
07S
RN, RH, CA, CT XN, XH, CA, CT
07M
XN, XH
XN, XH
10S
RN, RH, CA, CT XN, XH, CA, CT
10M
XN, XH, CA
XN, XH
15S
RH, RN, CA, CT XN, XH, CA, CT
15M
XN, XH
XN, XH
17M
CA
CA

104

Product Guide

240
277
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH
XN, XH
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
CA
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

480
XN, XH
XN, XH, CA
XN, XH, CA
CA

DT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA

MT1
MT2
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA, CT XN, XH, CA, CT
XN, XH
XN, XH
CA
CA

For photometric information, visit our website,


www.americanelectriclighting.com

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA

Decorative and Post Top Lighting


B A L L A S T

M AT R I C E S

Contempo Series 245


Watts
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M
20S
25S
25M
31S
40S
40M

120
RN, RH
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XN, XH, CA
RN, RH
RN, RH
RN, RH, CA, CT
XN, XH
CA
CA
XN, XH, CA
CA
CA, CT
CA, CT

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA
CA, CT
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
RN, RH, CA
XN, XH, CA
CA
CA, CT
CA, CT

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA
CA, CT
CA

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA, SC
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
CA, CT
CA, CT
-

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
CA, CT, SC
CA
-

480
XN, XH
XN, XH, CA
XN, XH, CA
CA
CA
CA
CA, SC
CA
CA, SC

DT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA
CA
XN, XH, CA
CA, CT, SC
CA, CT
CA, CT

Contempo Series 245 continued


Watts
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M
20S
25S
25M
31S
40S
40M

MT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA, SC
CA

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA, SC
CA

5T4
CA
CA
CA
CA

TwistPack Series TWT


Wattage
05S
07S
07M
10S
10M
15S
15M
17M
20S
25S
25M

120
RN,RH
RN, RH, CA, CT
XN, XH
RN, RH, CA, CT
XN, XH, CA
RN, RH, CA, CT
XN, XH
CA
CA
XN, XH, CA
CA

208
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA

240
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
RN, RH, CA
XN, XH, CA
CA

277
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA

TT3
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
CA, CT
CA, CT

5T4
CA
CA

347
XN, XH
XN, XH
XN, XH, CT
XN, XH
XN, XH
CA
CA
CA, CT, SC

480
XN, XH
XN, XH, CA
XN, XH, CA
CA
CA
CA
CA, SC

DT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH
CA
CA
XN, XH, CA
CA, CT, SC

MT1
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA, SC

TwistPack Series TWT continued


Wattage
05S
07S
07M
10S
10M
15S
15M
17M
20S
25S
25M

MT2
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA, SC

MT7
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
CA
CA
CA
CA, SC

Product Guide

105

NOTES

106

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

SECURITY LIGHTING
NEMA Head Series 11 ...........................................108
NEMA Head Package Series 11 PKG .................110
Series 11 L Package...........................................112
Dusk To Dawn Series DTD....................................114
Series 165 ................................................................116
Accessories ............................................................118
Ballast Matrices .....................................................119

American Electric Lighting

107

NEMA Head Series 11


Security Lighting
50-250W HPS, 100-175W MH

P R O D U C T

O V E R V I E W

Features:
Die-cast aluminum head meets NEMA dimension standards
For quick easy installation of mast arm, a cast-in external slipfitter is used for a
secure mounting
Available in a variety of IES light distribution patterns , including full cutoff
Tools are not required to install reflector and refractor
Tool-less adjustable photocontrol mount
Available for arm size 1-1/4" (standard) and 2" fitter
Open bottom acrylic, polycarbonate, or glass
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.6, C136.10

Applications:
Security areas
Storage yards
Loading areas
Receiving areas
DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

11 10S RN 120 R5 BA SW5


11 10S RN 120 RO LO
11 15S RN 120 R5 BA SW5
11 15S RN 120 RO LO
11 10M XN 120 R5 BA MDO

Approx. Wt. = 16 lbs.

Vented Bottom Acrylic (VBA)


Approx. Wt. = 16 lbs.

108

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Full Cutoff (FC)

NEMA Head Series 11


Security Lighting
50-250W HPS, 100-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: 1 1 1 0 S R N 1 2 0 R 5 B A

Wattage / Source

Series
11 NEMA
Head

05
07
10
15
17
25

50W
70W
100W
150W
175W
250W

Voltage

Ballast
RN Reactor Normal
Power Factor
XN High Reactance / Lag
Normal Power Factor
CA CWA, Auto Reg.

S HPS
M MH

Refer to the ballast matrix on


page 119 for compatibility.

120
208
240
277
MT1
MT2
MT7

120V
208V
240V
277V
120V Multi-tap
240V Multi-tap
277V Multi-tap

Distribution
R2
R3
R5
RO

Type II
Type III
Type V
No Optics (not for
MH)

Optics
LO
BA
BP
FC
BG
VBA

Options
2

Mast Arm
M4 24" Arm
M3 30" Arm
Photocontrol Receptacle
(blank) Standard
3
NR No Photocontrol Receptacle
Supply Wire4
SW5 Pre-wire 5'
PW5 Wired to Terminal Block 5'
(For more options see page 118)
Starter5
(blank) Open Board Standard
EC Encapsulated Starter

Fitter Size
(blank) 1-1/4 Fitter
H2 2 Fitter set for 1-1/4
Lamp
LC Lamp Included, Clear
LD Lamp Included, Deluxe/Coated
Misc.
PC
NL
LA
SH
MDO

Photocontrol Included per


Voltage Specified
NEMA Label
Lightning Arrestor
Shorting Cap5
Medium Base Socket,
Open Rated
(100W and 150W MH only)7

Less Optics
Open Bottom Acrylic6
Open Bottom Polycarbonate
Full Cutoff1,7,8
Open Bottom Glass6
Vented Bottom Acrylic
(required for mogul base MH
lamp only)

Notes:
1
2
3
4
5
6
7
8

Available in R5 distribution only


Available in 1 " aluminum pipe only
Not available with PC or DPC option
Standard with #14 copper solid, black-white, THHN
HPS only
MH version requires open rated socket (MDO)
Requires open rated lamp
Nighttime FriendlyTM optic

Product Guide

109

NEMA Head Package Series 11 PKG


Security Lighting
50-250W HPS, 100-175W MH

P R O D U C T

O V E R V I E W

Features:
Die-cast aluminum head meets NEMA dimension standards
For quick easy installation of mast arm, a cast-in external slipfitter is used for a
secure mounting
Available in a variety of IES light distributions patterns including full cutoff
Tools are not required to install reflector and refractor
Includes 24, 1-1/4 diameter mast arm with welded brackets, lamp,
photocontrol, 5 of supply wire, and hardware
All electrical components warranted by American Electric Lighting's 6-year
guarantee
All components in single carton
Open bottom acrylic, polycarbonate, or glass
Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.6, C136.10

Applications:
PREFERRED SELECTION CATALOG NUMBERS

Security areas
Storage yards
Loading areas
Receiving areas

11PKG 10S RN 120 R5 BA EC


11PKG 15S RN 120 R5 BA EC
11PKG 10M XN 120 R5 BA MDO
DIMENSIONS

Vented Bottom Acrylic (VBA)

Note: Package includes welded bracket, 24 mast arm 1-1/4


diameter, lamp, photocontrol, 5 of supply wire and hardware.
Approx. Wt. = 18 lbs.

110

Product Guide

Full Cutoff (FC)

For photometric information, visit our website,


www.americanelectriclighting.com

NEMA Head Package Series 11 PKG


Security Lighting
50-250W HPS, 100-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: 1 1 P K G 1 5 S R N 1 2 0 R 5 B A E C

Wattage / Source

Series
11PKG NEMA Head
Package

05
07
10
15
17
25

50W
70W
100W
150W
175W
250W

S HPS
M MH

Ballast
CA CWA, Auto Reg.1
RN Reactor/Normal
Power Factor
XN High Reactance/Lag
Normal Power Factor

Refer to the ballast matrix on


page 119 for compatibility.

Voltage
120
208
240
277
MT1
MT8
MT2
MT7

Optics

Distribution

120V
208V
240V
277V
120V Multi-tap
208V Multi-tap
240V Multi-tap
277V Multi-tap

R2 Type II
R3 Type III
R5 Type V

BA Open Bottom
Acrylic3
BP Open Bottom
Polycarbonate
FC Full Cutoff2,3,6
BG Open Bottom
Glass
VBA Vented Bottom
Acrylic (required
for MH)

Options
Photocontrol (per voltage specified)
(blank) Photocontrol (standard)
Starter4
(blank) Open Board (standard)
EC Encapsulated Starter

Lamp
(blank)
LD
Misc.
NL
MDO

Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated

NEMA Label
Medium Base Socket,
Open Rated
(100W and 150W MH only)5

1
2
3
4
5
6

Available in 175W MH only


Available in R5 distribution only
MH version requires open rated lamp
Available in HPS only
Open rated lamp supplied
Nighttime FriendlyTM optic

Product Guide

111

Series 11 L Package
Security Lighting
50-150W HPS

P R O D U C T

O V E R V I E W

Features:
Die-cast aluminum head meets NEMA dimension standards
For quick easy installation of mast arm, a cast-in external slipfitter is used for
a secure mounting
Includes 18 mast arm, lamp, photocontrol, pre-wire, and hardware
All components in single carton
Open bottom acrylic
Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.6, C136.10
UL Listed for wet locations

Applications:
Rural areas
Area lighting
Small businesses

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

11L 10S RN 120 R5 BA


11L 15S RN 120 R5 BA

Note: Package includes 18 mast arm, lamp, photocontrol, pre-wire, and hardware.
Approx. Wt. = 18 lbs.

112

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Series 11 L Package
Security Lighting
50-150W HPS

O R D E R I N G

I N F O R M AT I O N

Example: 1 1 L 1 5 S X N 1 2 0 R 5 B A

Wattage / Source

Series
05
07
10
15

11L Security
Package

50W
70W
100W
150W

S HPS

Refer to the ballast matrix on


page 119 for compatibility.

Ballast
RN Reactor Normal Power
Factor
XN High Reactance / Lag
Normal Power Factor

Voltage
120
208
240
277
MT1
MT2
MT7

Optics

Distribution

120V
R5 Type V
208V
240V
277V
120V Multi-tap
240V Multi-tap
277V Multi-tap

BA Open Bottom Acrylic

Options
Photocontrol (per voltage specified)
(blank) Photocontrol (standard)

Notes:
1 Available in 1-1/4 aluminum pipe only

Mast Arm
WA Welded Arm (24 mast arm)1
Listing
(blank)
CS

Package includes 18 mast arm, lamp, photocontrol,


pre-wire and hardware
UL Listed (standard)
CSA Certified

Product Guide

113

Dusk to Dawn Series DTD


Security Lighting
150-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
Ballast is completely enclosed in arm, but is readily accessible
All components in single carton
Refractor available in open bottom acrylic, or polycarbonate
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30C MH & / -40C HPS
Complies with ANSI: C136.2, C136.10

Applications:
Rural areas
Small businesses
Storage lots

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

DTD 15S RH 120 R5 BA CS LC PC NL


DTD 25S XN 120 R5 BA CS LC PC

Approx. Wt. = 23 lbs.

114

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Dusk to Dawn Series DTD


Security Lighting
150-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: D T D 1 5 S R H 1 2 0 R 5 B A

Wattage / Source

Series
DTD Dusk to Dawn

15
17
25
40

150W
175W
250W
400W

Voltage

Ballast

S HPS
M MH1

Refer to the ballast matrix on


page 119 for compatibility.

RN
RH
CA
CT
XN

Reactor Normal Power Factor


Reactor High Power Factor
CWA Auto Reg
CWI
High Reactance (Lag) Normal
Power Factor
XH High Reactance (Lag) High
Power Factor

120
240
277
347
480
MT1
MT2
MT7
TT3

120V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V

Distribution
R5 Type V

Optics
BA Open Bottom
Acrylic

Options
Standard Listing
(blank) No Listing
CS CSA Certified
Photocontrol
NR No Photocontrol Receptacle2
Lamp
LC
LD

Misc
PC
NL
SH

Notes:
Photocontrol Included
per Voltage Specified
NEMA Label
Shorting Cap

1
2

Requires open rated lamp


Not available with PC or SH option

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Product Guide

115

Series 165
Security Lighting Ballast-In-Arm
50-400W HPS, 175-400W MH

P R O D U C T

O V E R V I E W

Features:
One piece die cast aluminum head and arm configuration for long-life stability
and performance
Optical assembly utilizes dual latch mounting for quick, easy and secure
installation
Electrical components mounted to power door for installation and
maintenance convenience
Gray polyester powder coated housing finish is standard
Refractors available in open bottom acrylic, polycarbonate and glass
NEMA Label standard
Open board starter standard on HPS units
Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.10, C136.15, C136.6
6 of supply wire and hardware included

Applications:
Parking lots
Roadways
Commercial environments
Office communities
DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

165 25S XN 120 R5 BA LC PC


165 20S XN 120 R5 BA PJ0 LC
165 40S CA MT1 R5 BG LC PC
165 40M SC MT1 R5 BG LC PC

Approx. Wt. = 35 lbs.

116

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Series 165
Security Lighting Ballast-In-Arm
50-400W HPS, 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 1 6 5 4 0 S C A 1 2 0 R 5 B A L C P C

Wattage / Source

Series
165 Ballast-in
Arm

05
07
10
15
17
20
25
40

S HPS
M MH

50W
70W
100W
150W
175W
200W
250W
400W

Voltage

Ballast

Refer to the ballast matrix on


page 119 for compatibility.

RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
CT CWI
SC SCWA
MR Mag Reg

120
208
240
277
480
MT1
MT2
MT7

120V
208V
240V
277V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V

Distribution
R3 Area Type III
R5 Area Type V

Optics
BA Open Bottom
Acrylic
BP Open Bottom
Polycarbonate
BG Open Bottom
Glass1

Options
Terminal Block
(blank) Hard Wired (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)2
Fusing3
SF
DF

Single Fuse (120, 277V)


Double Fuse (208, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle4

Starter
(blank)
EC

Open Board (standard)


Encapsulated Starter5

Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Misc.
PC
TL
SS

Notes:
1
2
3
4
5

Not available in R4 distribution


T3 option only available with 240, 480, DT2, DT4, MT2
Not available with MT
PC option not available with NR option
Available in HPS only

Photocontrol Included per


Voltage Specified4
Tool-less Entry
Stainless Steel Hardware

Product Guide

117

Accessories

P
S

Pre-wired to terminal block


Supply wire included in carton

WIRE SIZE AND SPECIFICATION

W I R E

A
B
C
D
E
F
G
H
I
J
K
L
W
M
N

#10 CU Solid B/W


#10 CU Solid B/B
#10 CU Solid B/B/W
#10 CU Stranded B/W
#10 CU Stranded B/B
#10 CU Stranded B/B/W
#12 CU Solid B/W
#12 CU Solid B/B
#12 CU Solid B/B/WD
#12 CU Stranded B/W
#12 CU Stranded B/B
#12 CU Stranded B/B/W
#14 CU Solid B/W
#14 CU Solid B/B
#14 CU Solid B/B/W

LENGTH

P R E - S U P P LY

4
5
6
8
0

4
5
6
8
10

Examples
SW5 = 5 of #14 CU. Solid, B/W wire supplied in carton
PW5 = 5 of #14 CU. Solid, B/W pre-wired to terminal block
PD0 = 10 of #10 CU. Stranded, B/W pre-wire to terminal block

118

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Security Lighting
B A L L A S T

M AT R I C E S

Nema Head 11
Watts
05S
07S
10S
10M
15S
17M
25S

120
RN
RN
RN
XN
RN
CA
XN

208
XN
XN
XN
XN
CA
-

240
XN
XN
XN
XN
CA
RN

277
XN
XN
XN
XN
CA
-

MT1
XN
XN
XN
XN
CA
-

MT2
XN
XN
XN
XN
CA
-

MT7
XN
XN
XN
XN
CA
-

Nema Head Package Series 11PKG


Watts
05S
07S
10S
10M
15S
17M
25S

120
RN
RN
RN
XN
RN
CA
XN

208
XN
XN
XN
XN
CA
-

240
XN
XN
XN
XN
CA
RN

277
XN
XN
XN
XN
XN
CA
-

MT1
XN
XN
XN
XN
CA
-

MT2
XN
XN
XN
XN
CA
-

MT7
XN
XN
XN
XN
CA
-

240
XN
XN
XN
XN

277
XN
XN
XN
XN

MT1
XN
XN
XN
XN

MT2
XN
XN
XN
XN

MT7
XN
XN
XN
XN

Series 11L Package


Watts
05S
07S
10S
15S

120
RN
RN
RN
RN

208
XN
XN
XN
XN

TT3
XN
XN
XN

Dusk To Dawn
Watts
15S
17M
25S
40S

120
RN,RH,CA,CT,MR
CA
XH,XN,CA,CT,MR
CA,CT,XN,XH

240
CA,CT,XN,XH,MR
CA
RN,RH,CA,CT,MR
RH,RN,CA,CT

277
XN,XH,CA
CA
CA,CT
CA,CT

480
CA,MR
CA
CA,MR
CA

MT1
XN,XH,CA,CT
CA
CA,CT
CA,CT

MT2
XN,XH,CA,CT
CA
CA,CT
CA,CT

MT7
XN,XH,CA,CT
CA
CA,CT
CA,CT

TT3
XN,XH
CA
CA

Series 165
Watts
05S
07S
10S
15S
17M
25M
20S
25S
40S
40M

120
RH,RN
RH,CA,CT,RN,MR
CA,CT,MR,RH,RN
RN,RH,CA,CT,MR
CA
CA,CT,SC
CA, CT, XN, XH MR
XH,XN,CA,CT
CA,CT,XN,XH
CA

208
XH,XN
XH,CA,CT,XN
XH,CA,CT,XN
CA,CT,XN,XH
CA
CA,CT,SC
CA, CT
CA,CT
CA,CT
CA

240
XH,XN
XH,CA,CT,MR,XN
XH,CA,CT,MR,XN
CA,CT,XN,XH,MR
CA
CA,CT,SC
CA,CT,RN,RH,MR
RN,RH,CA,CT
RH,RN,CA,CT
CA

277
XH,XN
XH,CA,XN
CA,XH,XN
XN,XH,CA
CA
CA,SC
CA,CT,MR
CA,CT
CA,CT
CA

480
MR
CA
CA,MR
CA
CA,CT
CA,CT,MR
CA
CA
CA

MT1
XH,XN
XH,XN,CA
CA,XN,XH
XN,XH,CA,CT
CA
CA,SC
CT,CA
CA,CT
CA,CT
CA,SC

MT2
XN,XH
XH,XN,CA,
CA,XN,XH
XN,XH,CA,CT
CA
CA,SC
CT,CA
CA,CT
CA,CT
CA

MT7
XN,XH
XH,XN,CA,
CA,XN,XH
XN,XH,CA,CT
CA
CA,SC
CT,CA
CA,CT
CA,CT
CA

Product Guide

119

NOTES

120

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

AREA LIGHTING
ASA ........................................................................122
PES ........................................................................124
PEM ........................................................................126
VMR ........................................................................128
VLR ........................................................................130
AVL-BIA ................................................................132
AVL ..........................................................................134
LuxMaster Luminaire Series 53 ......................136
LuxMaster Luminaire Series 153 ....................138
LuxMaster Classic Series LS............................140
LuxMaster Classic Series LM ..........................142
Accessories ..........................................................144
Ballast Matrices....................................................148

American Electric Lighting

121

ASA
Area Lighting
70-400W HPS, 70-400W MH

P R O D U C T

O V E R V I E W

Features:

NEW

Superior electrical and thermal performance backed by AELs 6-year electrical


warranty
Industry leading Dark To LightTM electronic photocontrol included with PC
option
Stainless steel external hardware available
Impact resistant flat glass
Rugged die-cast aluminum enclosure, polyester powder coat paint finish
Rotatable and interchangeable R2, R3 and R5 hydroformed optics, segmented
forward throw reflector with R4 distribution
Aluminum extruded arms available in 4 or 9 mounting for square, round or
wood poles
External horizontal mast arm fitter mounting option
Tool-less entry latching option

Applications:

Tool-less PEC receptacle, standard

Parking lots
Roadways
Commercial environments
Office communities

Housing sealed with high temperature silicone gasketing


Terminal block and phosphor bronze PEC receptacle contacts, standard

PREFERRED SELECTION CATALOG NUMBERS

DIMENSIONS

ASA 24S CA MT7 R2 SP4 SH


ASA 40M SC MT1 R3 SP4 LC PC
ASA 40M SC MT1 R5 SP4 LC PC

Effective Projected Area (EPA)


The EPA for the ASA is 1.7 sq. ft. with a 4arm; 1.8 sq. ft. with a 9 arm
Approx. Wt = 37 lbs.

122

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

ASA
Area Lighting
70-400W HPS, 70-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: A S A 4 0 M C A M T 1 R 3 S P 4 L C P C

Wattage / Source

Series
ASA Architectural
Site Area Light

S HPS
70W
M MH
100W
150W
175W
200W
250W
310W
400W
250/400W
Wired 250W
24 250/400W
Wired 400W

07
10
15
17
20
25
31
40
23

RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
XH High Reactance
(Lag) High
CA CWA (Auto Reg)
CT CWI
SC SCWA

Distribution

Voltage

Ballast
120
208
240
277
347
480
MT1
MT2
MT7
TT3
5T4

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
5-Tap Wired 480V

R2 Area Type II
R3 Area Type III
R4 Type IV Forward
Throw, Sharp Cutoff1
R5 Type V, Symmetric

Mounting
(blank)
SP4
SP9
RP4
RP9
WW4
WW9

Refer to the ballast matrix on


page 148 for compatibility.

Less Mounting8
Square, 4
Square, 9
Round, 4
Round, 9
Wood, 4
Wood, 9

Shipped Separate
RKASA EF BZ External Mast
Arm Mount
Options
Paint2
(blank)
BK
GY
WH

Bronze (standard)
Black
Gray
White

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)3
Listing
(blank)
CS
XL

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Fusing6
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Misc.
PC
TL
SS

UL Listed (standard)
CSA Certified
No Listing

Notes:

Lamp
LC
LD

5H
NL
SH

Photocontrol Included per


Voltage Specified
Tool-less Entry
Stainless Steel Fasteners
(external)
50 Hertz Ballast Frequency7
NEMA Label
Shorting Cap

1
2

3
4
5
6
7

Segmented reflector, not rotatable


Other colors available, please contact
your local American Electric Lighting
representative
Not available for 120V fixtures
PC & SH not available with NR option
HPS only
Not available in MT or TT voltages
Limited availability, please contact
your local American Electric Lighting
representative
Order less mounting for mast arm mount

Photocontrol Receptacle
(blank) Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle4
Starter5
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Board Plug-in

Product Guide

123

Available Summer 2008

PES
Area Lighting
70-150W HPS, 100-250W MH

P R O D U C T

O V E R V I E W

Features:

NEW

Rugged, heavy-gauge, premium extruded aluminum housing


Square shape, seam-welded and internally sealed for weathertight integrity
Standard finish is dark bronze corrosion resistant polyester powder
Anodized, segmented reflectors for uniformity and control
Reflectors are tool-less, rotatable and interchangeable
3 cutoff distributions available, R2, R3 and FT
Natural anodized, extruded aluminum door frame sealed to housing by silicone
closed-cell gasket. Can be hinged from any of the four sides
Lens is .125 thick, impact-resistant tempered glass
Rugged die-cast aluminum enclosure, polyester powder coat paint finish
Extruded 4 aluminum arm for square pole mounting is standard, optional
mountings available

Applications:

High reactance, high power factor for 150W and below. Removable power tray
and positive-locking disconnect plug

Parking lots
Street lighting
Parking areas

Medium-base socket for 150W MH and below. Mogul-base porcelain socket


with copper alloy, nickel-plated screw shell and center contact
Terminal block and phosphor bronze PEC receptacle contacts, standard
UL Listed 1500W-600V. 4KV pulse rated
UL Listed, standard. CSA Certified or NOM Certified. UL Listed for wet
locations

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

PES 10M XH MT1 FT SP4 LC PC


PES 10S CA MT1 R3 SP9 LC PC

Effective Projected Area (EPA)


The EPA for the PES is 1.3 sq. ft.
Approx. Wt = 26.6 lbs.

124

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Available Summer 2008

PES
Area Lighting
70-150W HPS, 100-250W MH

O R D E R I N G

I N F O R M AT I O N

Example: P E S 1 5 S R N 1 2 0

Series

Wattage / Source

PES Premium Small

S HPS
07 70W
M MH
10 100W
13 100/150W
wired 100
14 100/150W
wired 150
15 150W
17 175W
25 250W1

RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
XH High Reactance
(Lag) High
CA CWA (Auto Reg)

Distribution

Voltage

Ballast
120
208
240
277
347
480
MT1
MT2
MT7
TT3

R2 SP9 PC

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V

R2 Roadway Type II
R3 Roadway Type III
FT Forward Throw,
Sharp Cutoff

Refer to optical matrix


below for compatibility

Refer to the ballast matrix on


page 148 for compatibility.

Mounting
(blank)
SP4
SP9
RP4
RP9
WW4
WW9

Less Bracket for


Mast Arm Mount
Square, 4 (standard)
Square, 9
Round, 4
Round, 9
Wood, 4
Wood, 9

Shipped Separate
RKPES EF BZ External Mast
Arm Mount
Options
Paint
(blank)
BK
WH

Bronze (standard)
Black
White

Terminal Block
(blank) Wire Nuts (standard)
TB Wired to L1 & N Positions
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L3
Position)
Listing
(blank)
CS
XL

Starter
(blank)
EC
OP
Lamp
LC
Fusing
SF
DF
Misc.
PC

UL Listed (standard)
CUL or CSA Listed
No Listing

Photocontrol Receptacle
(blank) Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle

TL
5H
SH
NL

Notes:
Open Board (standard)
Encapsulated Plug-in
Open Board Plug-in

MA only

Lamp Included, Clear

Single Fuse (120, 277, 347V)


Double Fuse (208, 240, 480V)

Photocontrol Included per


Voltage Specified
Tool-less Entry
50 Hertz Ballast Frequency
Shorting Cap
NEMA Label

Optic Distribution
07S
10S
10M
15S
15M
17M
25M

R2
N
N
N
N
N
N
N

R3
N
N
N
N
N
N
N

FT
N
N
N
N
N
N
N

Product Guide

125

Available Summer 2008

PEM
Area Lighting
200-400W HPS, 250-400W MH

P R O D U C T

O V E R V I E W

Features:

NEW

Rugged, heavy-gauge, premium extruded aluminum housing


Square shape, seam-welded and internally sealed for weathertight integrity
Standard finish is dark bronze corrosion resistant polyester powder
Anodized, segmented reflectors for uniformity and control
Reflectors are tool-less, rotatable and interchangeable
4 cutoff distributions available, R2, R3, R5 and FT
Natural anodized, extruded aluminum door frame sealed to housing by silicone
closed-cell gasket. Can be hinged from any of the four sides
Lens is .125 thick, impact-resistant tempered glass
Rugged die-cast aluminum enclosure, polyester powder coat paint finish
Extruded 4 aluminum arm for square pole mounting is standard, optional
mountings available

Applications:
Parking lots
Roadways
Commercial environments
Office communities

Constant wattage autotransformer for 250W and above. Removable power


tray and positive-locking disconnect plug
Mogul-base porcelain socket with copper alloy, nickel-plated screw shell and
center contact
Tool-less PEC receptacle, standard
Terminal block and phosphor bronze PEC receptacle contacts, standard
UL Listed 1500W-600V. 4KV pulse rated
UL Listed, standard. CSA Certified or NOM Certified. UL Listed for wet
locations

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

PEM 40M SC MT1 R5 SP9 LC PC


PEM 40M SC MT1 FT SP9 LC PC

Effective Projected Area (EPA)


The EPA for the PEM is 1.9 sq. ft.
Approx. Wt = 39.9 lbs.

126

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Available Summer 2008

PEM
Area Lighting
200-400W HPS, 250-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: P E M 4 0 M C A M T 1 R 3 S P 4 L C P C

Wattage / Source

Series
PEM Premium
Medium

20
25
31
32
35
40

200W
250W
310W
320W
350W
400W

S HPS
M MH

Refer to the ballast matrix on


page 149 for compatibility.

RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
XH High Reactance
(Lag) High
CA CWA (Auto Reg)
SC SCWA

Distribution

Voltage

Ballast
120
208
240
277
347
480
MT1
MT2
MT7
TT3

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V

R2
R3
R5
FT

Roadway Type II
Roadway Type III
Type V, Square
Forward Throw,
Sharp Cutoff

Refer to optical matrix


below for compatibility

Mounting
(blank)
SP4
SP9
RP4
RP9
WW4
WW9

Less Bracket for


Mast Arm Mount
Square, 4
Square, 9
Round, 4
Round, 9
Wood, 4
Wood, 9

Shipped Separate
RKPEM EF BZ External Mast
Arm Mount
Options
Paint
(blank)
BK
WH

Bronze (standard)
Black
White

Terminal Block
(blank) Wire Nuts (standard)
TB Wired to L1 & N Positions
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L3
Position)
Listing
(blank)
CS
XL

Starter
(blank)
EC
OP
Lamp
LC
Fusing
SF
DF
Misc.
PC

UL Listed (standard)
CUL or CSA Listed
No Listing

Photocontrol Receptacle
(blank) Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle

TL
5H
SH

Open Board (standard)


Encapsulated Plug-in
Open Board Plug-in
Lamp Included, Clear

Single Fuse (120, 277, 347V)


Double Fuse (208, 240, 480V)

Photocontrol Included per


Voltage Specified
Tool-less Entry
50 Hertz Ballast Frequency
Shorting Cap

Optic Distribution
20S
25S
25M
31S
32M
35M
40S
40M

R2
N
N
N
N
N
N
N
N

R3
N
N
N
N
N
N
N
N

R5
N
N
N
N
N
N
N
N

FT
N
N
N
N
N
N
N
N

Product Guide

127

Available Summer 2008

VMR
Area Lighting
70-150W HPS, 50-200W MH

P R O D U C T

O V E R V I E W

Features:

NEW

Heavy-gauge, spun aluminum housing


Integral structural support plate for mounting arm and electrical components
ensures rigidity and strength
Hinged aluminum door frame incorporates stainless steel hardware
Continuous silicone gasketing surrounds lens for weather-tight seal
Thermal, shock-resistant tempered flat or drop glass lens
Standard finish is dark bronze, electrostatically applied powder paint. Linear
embossed accent reveals are standard. Additional architectural colors and
striping are available
Most flat lens configurations meet full-cutoff criteria. Vertical-lamp reflectors
are one-piece spun and formed anodized aluminum
High performance segmented aluminum reflectors are used with horizontal
lamps. They are rotatable and interchangeable

Applications:

High reactance, high power factor for 50-150W. Constant wattage


autotransformer for 175W. Metal halide 150W and below are standard with
pulse-start ignitor technology; super SCWA pulse-start ballast required for
200W

Parking lots
Street lighting
Parking areas

Porcelain, horizontally mounted medium base socket with copper alloy, nickelplated screw shell and center contact
Arms are available for use with various poles, wall mounting and unique
configurations. 4 aluminum fitter for open-top pole is available
Listed and labeled to UL standards for 25C ambient and wet locations. Listed
and labeled to CSA standards. NOM Certified
DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

VMR 10M XH MT1 SM DG P9 LC PC TL


VMR 10M XH MT1 SM FG P9 LC PC TL
VMR 10S CA MT1 SM FG P9 LC PC TL
11.55
(293)

Effective Projected Area (EPA)


The EPA for the VMR Arm Mount is 1.8 sq. ft., Approx. Wt = 35 lbs.
The EPA for the VMR Post-top is 1.9 sq. ft.

128

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Available Summer 2008

VMR
Area Lighting
70-150W HPS, 50-200W MH

O R D E R I N G

I N F O R M AT I O N

Example: V M R 1 7 M C A 1 2 0 S M F G S 9 L C

Series
VMR Vertical
Medium
Round

Wattage / Source
05
07
10
15
17
20

50W
70W
100W
150W
175W
200W

S HPS1
M MH

Distribution

Voltage

Ballast

RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance /
Lag Normal
Power Factor
Refer to the ballast matrix on XH High Reactance /
page 149 for compatibility.
Lag High
Power Factor
CA CWA
SC SCWA2
CT CWI

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap Wired 480V

Vertical Lamp
AM Asymmetric
SM Symmetric
Horizontal Lamp
R2 Area Type II
R3 Area Type III
FT Forward Throw,
Sharp Cutoff
R5 Area Type V

Bronze (standard)
Black
Gray
White

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Listing
(blank)
CS

UL Listed (standard)
CSA Certified

Fusing5
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle6
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
A4
PC
TL
SS
5H
NL
SH

4-7/8 Hole Spacing on Housing


and Arm
Photocontrol Included per
Voltage Specified6
Tool-less Entry
Stainless Steel Fasteners (external)
50 Hertz Ballast Cycle8
NEMA Label on Housing
Shorting Cap6

Accessories (shipped separately)


VMREHS U Field Installable External HS Shield
Universal Tenon Adapter

FG Flat Glass Clear


Tempered9
DG Drop Glass Clear
Tempered

Refer to optical matrix


below for compatibility

Mounting3
S9
P9
S2
P2
WP
WB
EF
P3
P7
S3
S7
PT4

Options
Paint4
(blank)
BK
GY
WH

Optics

Square Pole, 9 Arm


Round Pole, 9 Arm
Square Pole, 12 Arm
Round Pole, 12 Arm
Wood Pole or Wall, 12 Arm
Wall Bracket, 12 Arm
External Mast Arm Fitter
Round Pole Fitter, 2-3/8 OD
Round Pole Fitter, 2-7/8 OD
Square Pole Fitter, 2-3/8 OD
Square Pole Fitter, 2-7/8 OD
Spider Mount, 4 OD, Open
Top Pole

Notes:
1
2
3
4

5
6
7
8

Not available with SCWA


Pulse Start Metal Halide only
Standard arm-hole bolt spacing is 4-1/4.
For 4-7/8 spacing, order A4 option.
Other colors available, please contact
your local American Electric Lighting
representative
Voids UL/CSA Listing, not available with
MT, TT, and DT voltages
PC & SH not available with NR option
HPS only, 400W max
Limited availability, please contact
your local American Electric Lighting
representative
Nighttime FriendlyTM optic

Optic Distribution
07S
10S
10M
15S
15M
17M
20M

AM FG SM FG FT FG R2 FG R3 FG R5 FG AM DG SM DG FT DG R2DG R3DG
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Product Guide

129

Available Summer 2008

VLR
Area Lighting
250-1000W HPS, 175-1000W MH

P R O D U C T

O V E R V I E W

Features:

NEW

Heavy-gauge, spun aluminum housing


Integral structural support plate for mounting arm and electrical components
ensures rigidity and strength
Hinged aluminum door frame incorporates stainless steel hardware
Continuous silicone gasketing surrounds lens for weather-tight seal
Thermal, shock-resistant tempered flat or drop glass lens
Standard finish is dark bronze, electrostatically applied powder paint. Linear
embossed accent reveals are standard. Additional architectural colors and
striping are available
Most flat lens configurations meet full-cutoff criteria. Vertical-lamp reflectors
are one-piece spun and formed anodized aluminum
High performance segmented aluminum reflectors are used with horizontal
lamps. They are rotatable and interchangeable

Applications:

Mogul base porcelain socket with copper alloy, nickel-plated screw shell and
center contact

Parking lots
Street lighting
Parking areas

Reflectors are rotatable and interchangeable


Arms are available for use with various pole and wall mounting. 4 aluminum
fitter for open-top pole is available
Listed and labeled to UL standards for 25C ambient and wet locations. Listed
and labeled to CSA standards. NOM Certified

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

VLR X1M CA MT1 SM FG P2 LC TL


VLR X1M CA MT1 SM DG P2 LC TL
VLR X1M SC MT7 SM FG P2 LC TL

Effective Projected Area (EPA)


The EPA for the PSE is 1.3 sq. ft.
Approx. Wt = 26.6 lbs.

130

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Available Summer 2008

VLR
Area Lighting
250-1000W HPS, 175-1000W MH

O R D E R I N G

I N F O R M AT I O N

Example: V L R 1 7 5 M C A 1 2 0 A M F G S 9 P C

Wattage / Source

Series
VLR Vertical Large
Round

17
25
32
35
40
X1

175W
250W
320W
350W
400W
1000W

Voltage

Distribution

Optics

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap wired 480V

Vertical Lamp
AM Asymmetric
SM Symmetric
FV Forward Throw

FG Flat Glass Clear


Tempered12
DG Drop Glass Clear
Tempered

Horizontal Lamp
R2 Area Type II
R3 Area Type III
FT Forward Throw,
Sharp Cutoff9

Refer to optical matrix


below for compatibility

Ballast

S HPS1,11
M MH10

CA CWA
SC SCWA2
CT CWI

Refer to the ballast matrix on


page 150 for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

S9
P9
S2
P2
WP
WB
EF
P3
P7
S3
S7
PT4

Options
Paint4
(blank)
BK
GY
WH
UP

Bronze (standard)
Black
Gray
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Listing
(blank)
CS
Fusing5
SF
DF

UL Listed (standard)
CSA Certified

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
A4

1
2
3
4

Accessories (shipped separately)


VLREHS U Field installable external HS shield
universal tenon adapter

9
10
11

TL
SS
5H
NL
SH

5
6
7
8

12
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle6
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Square Pole, 9 Arm


Round Pole, 9 Arm
Square Pole, 12 Arm
Round Pole, 12 Arm
Wood Pole or Wall, 12 Arm
Wall Bracket, 12 Arm
External Mast Arm Fitter
Round Pole Fitter, 2-3/8 OD
Round Pole Fitter, 2-7/8 OD
Square Pole Fitter, 2-3/8 OD
Square Pole Fitter, 2-7/8 OD
Spider Mount, 4 OD, Open
Top Pole

Notes:

4-7/8 Hole Spacing on Housing


and Arm
Photocontrol Included per
Voltage Specified6
Tool-less Entry
Stainless Steel Fasteners (external)
50 Hertz Ballast Cycle8
NEMA Label on Housing
Shorting Cap6

PC

Mounting3

Not available with SCWA


Pulse Start Metal Halide only
Standard arm-hole bolt spacing is 4-1/4.
For 4-7/8 spacing, order A4 option.
Other colors available, please contact
your local American Electric Lighting
representative
Voids UL/CSA Listing, not available with
MT, TT, and DT voltages
PC & SH not available with NR option
HPS only, 400W max
Limited availability, please contact
your local American Electric Lighting
representative
Not available with PT4 option
1000W MH uses reduced jacketed lamp
1000W HPS uses reduced jacketed lamp
for FG options
Nighttime FriendlyTM optic

Optic Distribution
25S
31S
40S
X1S
17M
25M
32M
35M
40M
X1M

AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2FG R3FG FT DG
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-

Product Guide

131

AVL BIA
Area Lighting Ballast-in-Arm
200-1000W HPS, 250-1000W MH

P R O D U C T

O V E R V I E W

Features:

NEW

Separate compartments provide ease of installation (reduced weight of


housing, short mounting bolts).
Rugged heavy gauge aluminum housing is continuously seam welded for
weathertight integrity
Silicone gasket seals optical compartment from moisture, insects and dust
Available in multiple mounting options to fit a variety of applications
Choice of drop or flat lens to allow for full cutoff compliance
Separate optical and electrical compartments provide lower internal
temperatures extending fixture life
Available in a variety of IES light distributions patterns
1000W MH designed around reduced jacket lamp
Tool-less die-cast trigger latches
Choice of bolt spacing for mounting arm (4-1/4 or 4-7/8)

Applications:

Mogul base, E39, socket standard

Parking lots
Roadways
Commercial environments
Office communities

All electrical components warranted by American Electric Lighting's 6-year


guarantee
Suitable for -30C MH / -40C HPS
Ballast tray(s) installable or removable without tools (trigger latch and plug-in
connections)

DIMENSIONS

AVL Drop Glass

AVL Flat Glass

Effective Projected Area (EPA)


Single
4.4 sq. ft.
2 @ 180
8.42 sq. ft.
2 @ 90
7.8 sq. ft.
3 @ 90
11.82 sq. ft.
4 @ 90
13.52 sq. ft.

132

Product Guide

Approximate Weight
99 lbs.
170 lbs.
170 lbs.
241 lbs.
312 lbs.

For photometric information, visit our website,


www.americanelectriclighting.com

AVL-Ballast-in-Arm

AVL BIA
Area Lighting Ballast-in-Arm
200-1000W HPS, 250-1000W MH

O R D E R I N G

I N F O R M AT I O N

Example: A V L B I A 1 X M C A M T 1 S M D G 4 9 0 3 0 F T

Wattage / Source

Series
AVL BIA

AVL
Ballast in Arm
AVL LMS AVL Low Mast
System

20
25
31
32
35
40
45
75
1X

200W
250W
310W
320W1
350W1
400W
450W1
750W
1000W1

Voltage

Distribution

Optics

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V

Vertical Lamp
AM Asymmetric
SM Symmetric
FV Forward Throw3

FG Flat Glass Clear


Tempered8
DG Drop Glass Clear
Tempered

Ballast

S HPS
M MH

CA CWA
SC SCWA2
CT CWI

Refer to the ballast matrix on


page 150 for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Horizontal Lamp
R2 Area Type II
R3 Area Type III

Refer to optical matrix


below for compatibility

Mounting7
Units
1
2
3
4

Pre-Wire Length7

Degrees
90
180
*Number of Units and
Degrees should be
combined to form one
number. Ex: 490

20FT
25FT
30FT
35FT
40FT
45FT
50FT
55FT
60FT

Options
Paint4
(blank)
BK
GY
WH
UP

Bronze (standard)
Black
Gray
White
Unpainted

Listing
UL
CS
MX

UL Listing
CSA Certified
NOM Listed

Misc.
PC
SS
NL
SH
4D
5H

Notes:
Photocontrol Included per
Voltage Specified
Stainless Steel Fasteners (external)
NEMA Label on Housing
Shorting Cap6
4 OD Tenon
50 Hertz Ballast Cycle6

Accessories (shipped separately)


AVLEHS U Field Installable External
House Side Shield

1
2
3
4

5
6

7
8

Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle6

Reduced jacket lamp only


Pulse Start Metal Halide only
Available in drop glass only
Other colors available, please contact
your local American Electric Lighting
representative
PC & SH not available with NR option
Limited availability, please contact
your local American Electric Lighting
representative
Not required for LMS
Nighttime FriendlyTM optic

Optic Distribution
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

25S
31S
40S
X1S
25M
32M
35M
40M
1XM

AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2DG R3DG FT DG
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-

Product Guide

133

AVL
Area Lighting
250-1000W HPS, 250-1000W MH

P R O D U C T

O V E R V I E W

Features:
Rugged heavy gauge aluminum housing is continuously seam welded for
weathertight integrity
Silicone gasket seals optical compartment from moisture, insects and dust
Available in multiple mounting options to fit a variety of applications
Choice of drop or flat lens to allow for full cutoff compliance
Available in a variety of IES light distributions patterns
1000W MH designed around reduced jacket lamp
Tool-less die-cast trigger latches
Choice of bolt spacing for mounting arm (4-1/4 or 4-7/8)
Mogul base, E39, socket standard
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30C MH / -40C HPS

Applications:
Parking lots
Roadways
Commercial environments
Office communities

DIMENSIONS

AVL Flat Glass

PREFERRED SELECTION CATALOG NUMBERS

AVL Drop Glass

AVL 1XM CA MT7 SM DG S9 TL


AVL 1XM SC MT1 SM DG S9 NR LC
AVL 1XM CA MT1 SM DG P2 NR LC TL

Effective Projected Area (EPA)


The EPA for the AVL is 2.8 sq. ft.
Approx. Wt = 53 lbs.

134

Product Guide

For photometric information please visit our website:


www.americanelectriclighting.com

AVL
Area Lighting
250-1000W HPS, 250-1000W MH

O R D E R I N G

I N F O R M AT I O N

Example: A V L 1 X M C A M T 7 S M D G S 9

Wattage / Source

Series
AVL American
Vertical
Luminaire

25
31
32
35
40
45
75
1X

250W
310W
320W1
350W1
400W
450W1
750W
1000W1

Voltage

Distribution

Optics

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap wired 480V

Vertical Lamp
AM Asymmetric
SM Symmetric
FV Forward Throw

FG Flat Glass Clear


Tempered9
DG Drop Glass Clear
Tempered

Ballast

S HPS
M MH

CA CWA
SC SCWA2
CT CWI

Refer to the ballast matrix on


page 150 for compatibility.

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

Horizontal Lamp
R2 Area Type II
R3 Area Type III
FT Area Type IV

Mounting3
S9
P9
S2
P2
WP
WB
EF
P3
P7
S3
S7
PT4

Options
Paint4
(blank)
BK
GY
WH
UP

Bronze (standard)
Black
Gray
White
Unpainted

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Listing
UL
CS
Fusing5
SF
DF

UL Listing
CSA Certified

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle6
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe/Coated

Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
A4
PC
TL
SS
5H
NL
SH
TL
4D

4-7/8 Hole Spacing on Housing


and Arm
Photocontrol Included per
Voltage Specified6
Tool-less Entry
Stainless Steel Fasteners (external)
50 Hertz Ballast Cycle8
NEMA Label on Housing
Shorting Cap6
Trigger Latch
4 OD Tenon

Accessories (shipped separately)


AVLEHS U Field Installable External HS Shield
Universal Tenon Adapter10

Refer to optical matrix


below for compatibility

Notes:
1
2
3
4

5
6
7
8

9
10

Square Pole, 9 Arm


Round Pole, 9 Arm
Square Pole, 12 Arm
Round Pole, 12 Arm
Wood Pole or Wall, 12 Arm
Wall Bracket, 12 Arm
External Mast Arm Fitter
Round Pole Fitter, 2-3/8 OD
Round Pole Fitter, 2-7/8 OD
Square Pole Fitter, 2-3/8 OD
Square Pole Fitter, 2-7/8 OD
Spider Mount, 4 OD, Open
Top Pole

Reduced jacket lamp only for MH


Pulse Start Metal Halide only
Standard arm-hole bolt spacing is 4-1/4.
For 4-7/8 spacing, order A4 option.
Other colors available, please contact
your local American Electric Lighting
representative
Voids UL/CSA Listing, not available with
MT, TT, and DT voltages
PC & SH not available with NR option
HPS only, 400W max
Limited availability, please contact
your local American Electric Lighting
representative
Nighttime FriendlyTM optic
See page 145 for options

Optic Distribution
25S
31S
40S
X1S
25M
32M
35M
40M
1XM

AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2DG R3DG FT DG
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
-

Product Guide

135

LuxMaster Series 53
Area Lighting
70-150W HPS, 175W MH

P R O D U C T

O V E R V I E W

Features:
Durable die-cast aluminum housing for long-life performance
Optical assembly designed for maximum performance
Removable ballast tray electrical system for installation and maintenance ease
"Breathing Seal" developed by American Electric prevents contaminants from
entering optical assembly for maximum efficiency
Optics available in flat tempered glass, sag glass, drop acrylic and drop
polycarbonate
Available in a variety of IES light distributions patterns and cutoff
classifications
Standard product is designed to mount to pipe mast arm. Direct pole mount
arms are available

Applications:

Arm ordered separate, see page 144

Parking lots
Roadways
Residential communities
Commercial environments
Office communities

All electrical components warranted by American Electric Lighting's 6-year


guarantee
UL Listed
Mogul base, E39, socket standard
Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

53 10S CA MT1 R2 DA
53 15S CA MT1 R2 FG
53 10S RH 120 R3 FG

Effective Projected Area (EPA)


The EPA for the LuxMaster Series 53 with
refractor 1.4 sq. ft.
Approx Wt = 30 lbs.

136

Product Guide

Effective Projected Area (EPA)


The EPA for the LuxMaster Series 53 with flat
lens is 1.1 sq. ft.

For photometric information please visit our website:


www.americanelectriclighting.com

LuxMaster Series 53
Area Lighting
70-150W HPS, 175W MH

O R D E R I N G

I N F O R M AT I O N

Example: 5 3 1 5 S C A M T 1 R 3 F G L C P C

53 LuxMaster
Shoebox

S HPS
M MH

07 70W
10 100W
13 100/150W
wired 100
14 100/150W
wired 150
15 150W
17 175W

Voltage

Ballast

Wattage / Source

Series

Refer to the ballast matrix on


page 151 for compatibility.

RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
MR Mag Reg (3 coil)
CT CWI

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2
DT4

Distribution

R2 Roadway Type II
120V
R3 Roadway Type III
208V
240V
Refer to optical matrix
277V
below for compatibility
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240 Wired 240V
Dual Tap 240/480 Wired 480V
Optics
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor
FG Flat Glass Clear
Tempered6
SG Sag Glass Refractor

Options
Mounting
(blank) Internal fitter (1-1/4)
M2 Internal fitter (pre-set 2)
Paint1
(blank)
BK
GY
WH

Bronze (standard)
Black
Gray
White

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Fusing2
SF
DF

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle3
Lamp
LC
LD

Lamp Included, Clear


Lamp Included, Deluxe

Starter4
(blank)
EC
OP
PS

Open Board (standard)


Encapsulated Plug-in
Open Plug-in
Protected/Auto Shutoff5

Listing
(blank)
CS

UL Listed (standard)
CSA Certified

Misc.
PC
SS
LA
5H
NL
SH
HK

Notes:
1
2
3
4
5
6

Other colors available, please contact your


local American Electric Lighting representative
Voids UL/CSA Certified Options and not
available in MT, TT, and DT voltages
PC, & SH not available with NR option
HPS only
Limited availability, please contact your local
American Electric Lighting representative
Nighttime FriendlyTM optic

Photocontrol Included per


Voltage Specified3
Stainless Steel Fasteners (external)
Lightning Arrestor (Void UL/CSA
Listed Options)
50 Hertz Ballast Cycle5
NEMA Label on Housing
Shorting Cap3
Hinge Keeper

Optic Distribution
05S
07S
10S
15S
17M

R2 DA
N
N
N
N
-

R3 DA
N
N
N
N
-

R2 DP
N
N
N
N
-

R3 DP
N
N
N
N
-

R2 FG
N
N
N
N
N

R3 FG
N
N
N
N
N

R2 SG
N
N
N
N
N

R3 SG
N
N
N
N
N

Product Guide

137

LuxMaster Luminaire Series 153


Area Lighting
200-400W HPS, 200-400W MH

P R O D U C T

O V E R V I E W

Features:
Die-cast aluminum housing for long-life performance
Optical assembly designed for maximum performance
Ballast tray electrical system for installation and maintenance ease
"Breathing Seal" developed by American Electric preventing contaminants
from entering optical assembly
Optics available in flat tempered glass, sag glass, drop acrylic and drop
polycarbonate
Available in a variety of IES light distributions patterns
Standard product is designed to mount to pipe mast arm. Direct pole mount
arms are available
Arm ordered separate, see page 144
UL Listed

Applications:

All electrical components warranted by American Electric Lighting's 6-year


guarantee

Parking lots
Roadways
Residential communities
Commercial environments
Office communities

Mogul base, 539 socket std.


Suitable for -30C MH / -40C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

153 40M SC MT1 R3 SG


153 25S CA MT1 R3 FG
153 40S CA MT1 R3 FG
153-1-BZ

Effective Projected Area (EPA)


The EPA for the LuxMaster HPS Luminaire
Series 153 with flat lens is 2.1 sq. ft.
Approx Wt = 45 lbs.

138

Product Guide

The EPA for the LuxMaster HPS Luminaire


Series 153 with drop lens is 2.4 sq. ft.

For photometric information please visit our website:


www.americanelectriclighting.com

LuxMaster Luminaire Series 153


Area Lighting
200-400W HPS, 200-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 1 5 3 2 5 S C A M T 1 R 3 F G L C E C P C

Wattage / Source

Series
153 LuxMaster
Shoebox

S HPS
M MH

20
25
31
40
23

200W
250W
310W
400W
250/400W
wired 250
24 250/400W
wired 400

Refer to the ballast matrix on


page 151 for compatibility.

Distribution

Voltage

Ballast
RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
MR Mag Reg (3 coil)
CT CWI
SC SCWA

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2
DT4

R2 Roadway Type II
120V
R3 Roadway Type III
208V
240V
Refer to optical matrix
277V
below for compatibility
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240 Wired 240V
Dual Tap 240/480 Wired 480V
Optics
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor
FG Flat Glass Clear
Tempered6
SG Sag Glass
Prismatic Refractor

Options
Mounting
(blank) Internal fitter (1-1/4)
M2 Internal fitter (pre-set 2)
Paint1
(blank)
BK
GY
WH

Single Fuse (120, 277, 347V)


Double Fuse (208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle3
Lamp
LC
LD

Notes:
1
2

Bronze (standard)
Black
Gray
White

Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Fusing2
SF
DF

Starter4
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in

Lamp Included, Clear


Lamp Included, Deluxe

Listing
(blank)
CS
Misc.
PC
SS
LA
5H
NL
SH
HK

UL Listed (standard)
CSA Certified

3
4
5

Photocontrol Included per


Voltage Specified3
Stainless Steel Fasteners (external)
Lightning Arrestor
50 Hertz Ballast Cycle5
NEMA Label on Housing
Shorting Cap3
Hinge Keeper

Other colors available, please contact your


local American Electric Lighting representative
Voids UL/CSA listing, not available with MT, TT,
and DT voltages
PC, & SH not available with NR option
HPS only
Limited availability, please contact your local
American Electric Lighting representative
Nighttime FriendlyTM optic

Optic Distribution
20S
25S
31S
40S
25M
40M

R2 DA
N
N
N
N
-

R3 DA
N
N
N
N
-

R2 DP
N
N
N
N
-

R3 DP
N
N
N
N
-

R2 FG
N
N

R3 FG
N
N
N
N
-

R2 SG
N
N
N
N
-

R3 SG
N
N
N
N
N
N

* Requires use of ED28 lamp

Product Guide

139

LuxMaster Classic Series LS


Area Lighting
70-150W HPS, 175W MH

P R O D U C T

O V E R V I E W

Features:
Rugged heavy gauge aluminum housing is continuously seam welded for
weathertight integrity
Multiple mounting options to fit a variety of applications
Optical assembly designed for maximum performance
Removable ballast tray electrical system for installation and maintenance ease
Mogul base, E39 socket standard
"Breathing Seal" developed by American Electric prevents contaminants from
entering optical assembly for maximum efficiency
Tempered flat glass lens standard, drop polycarbonate option available
Available in a variety of IES full cutoff light distributions patterns
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30C MH / -40C HPS

Applications:
Parking lots
Office complexes
Security lighting
Residential areas
Commercial environments
DIMENSIONS

Effective Projected Area (EPA)


The EPA for the LuxMaster Classic Luminaire, Series LS is 1.75 sq. ft.
Approx Wt. = 20 lbs.

140

Product Guide

For photometric information please visit our website:


www.americanelectriclighting.com

LuxMaster Classic Series LS


The following three separate components must be ordered:
1) BALLAST TRAY 2) HOUSING 3) MOUNTING

Area Lighting
70-150W HPS, 175W MH

Each Ships Separately

O R D E R I N G

1) Ballast Tray

Example: L S 1 5 S R H 1 2 0 R 3

Wattage / Source

Series
LS LuxMaster
Shoebox,
Small

07
10
15
17

I N F O R M AT I O N

S HPS
M MH

70W
100W
150W
175W

RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
CT CWI

Refer to the ballast matrix on


page 152 for compatibility.

Distribution

Voltage

Ballast
120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap WWired 277V
Tri-tap Wired 347V
Dual Tap 120/240 Wired 240V

R2 Roadway Type II
R3 Roadway Type III
R5 Roadway Type V
Options
Fusing1
SF
DF

Single Fuse
(120, 277, 347V)
Double Fuse
(208, 220, 240, 480V)

Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol
Receptacle2

O R D E R I N G

2) Housing
Series
LS LuxMaster
Shoebox,
Small

I N F O R M AT I O N

Example: L S 1 5 S R 3 P C H S G

Options

Wattage / Source
07
10
15
17
XX

S HPS
70W
M MH
100W
150W
175W
No Ballast3

Paint4
(blank)
BK
GY
WH

Distribution
R2 Roadway Type II
R3 Roadway Type III
R5 Roadway Type V

Housing

Misc.
SS

Bronze (standard)
Black
Gray
White

SH
PC
LC

Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol
Receptacle2

HSG Housing Unit


Stainless Steel
Fasteners (external)
Shorting Cap2
Photocontrol Included per
Voltage Specified2
Lamp Included, Clear

O R D E R I N G

I N F O R M AT I O N

3) Mounting

Example: L S P 3 B Z
Notes:
Paint

Mounting

Series

1
LM LuxMaster
Shoebox,
Small

P
W
K
M
Y
T
1
2

Square Pole 12 Arm


Wall Bracket 12 Arm
Adjustable Knuckle
External Fitter
Yoke Mount
Square Tenon
Square Tenon 2 Arms 90
Square Tenon 2 Arms 180

3
4
5
6
7
8
9
R

Square Tenon 3 Arms 90


Square Tenon 4 Arms 90
Round Tenon
Round Tenon 2 Arms 90
Round Tenon 2 Arms 180
Round Tenon 3 Arms 90
Round Tenon 3 Arms 120
Round Tenon 4 Arms 90

Paint4
BZ Bronze
(standard)
BK Black
GY Gray
WH White

2
3
4

Voids UL/CSA Certified Options and


not available in MT, TT, and
DT voltages
PC, & SH not available with
NR option
NL not available
Other colors available, please
contact your local American
Electric Lighting representative

Product Guide

141

LuxMaster Classic Series LM


Area Lighting
200-400M HPS, 250-400W MH

P R O D U C T

O V E R V I E W

Features:
Rugged heavy gauge aluminum housing is continuously seam welded for
weathertight integrity
Multiple mounting options to fit a variety of applications
Optical assembly designed for maximum performance
Removable ballast tray electrical system for installation and maintenance ease
Mogul base, E39 socket standard
"Breathing Seal" developed by American Electric prevents contaminants from
entering optical assembly for maximum efficiency
Tempered flat glass lens standard, drop polycarbonate option available
Available in a variety of IES full cutoff light distributions patterns
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30C MH / -40C HPS

Applications:
Office complexes
Parking lots
Residential areas
Commercial environments
Security lighting
DIMENSIONS

Effective Projected Area (EPA)


The EPA for the LuxMaster Classic Luminaire, Series LM is 2.36 sq. ft.
Approx Wt. = 45 lbs.

142

Product Guide

For photometric information please visit our website:


www.americanelectriclighting.com

LuxMaster Classic Series LM


The following three separate components must be ordered:
1) BALLAST TRAY 2) HOUSING 3) MOUNTING

Area Lighting
200-400M HPS, 250-400W MH

Each Ships Separately

O R D E R I N G

1) Ballast Tray

Example: L M 2 0 S X H 1 2 0 R 3

Wattage / Source

Series
LM LuxMaster
Shoebox,
Medium

I N F O R M AT I O N

S HPS
M MH

20 200W
25 250W
40 400W

RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
CT CWI
SC SCWA

Refer to the ballast matrix on


page 152 for compatibility.

Distribution

Voltage

Ballast
120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240 Wired 240V

O R D E R I N G

LM LuxMaster
Shoebox,
Medium

Options
Fusing1
SF

Single Fuse
(120, 277, 347V)
DF Double Fuse
(208, 220, 240, 480V)
Terminal Block
(blank) Terminal Block
(standard)
T2 Wired to L1 & L2
Positions
T3 3 Wire Operation
(L1, N, L2 Position)
Photocontrol Receptacle
NR No Photocontrol
Receptacle2

I N F O R M AT I O N
Example: L M 2 0 S R 3 H S G

2) Housing
Series

R2 Roadway Type II
R3 Roadway Type III
R5 Roadway Type V

Options

Wattage / Source
20
25
31
40

200W
250W
310W
400W

S HPS
M MH

Distribution

Paint3
(blank)
BK
GY
WH

Housing

Misc.
PC

Bronze (standard)
Black
Gray
White

SS
SH

HSG Housing Unit


Photocontrol Included per
Voltage Specified2
Stainless Steel
Fasteners (external)
Shorting Cap2

R2 Roadway Type II Photocontrol Receptacle


R3 Roadway Type III (blank) NEMA Photocontrol
Receptacle (standard)
R5 Roadway Type V
NR

No Photocontrol Receptacle2

O R D E R I N G

I N F O R M AT I O N

3) Mounting

Example: L M P 3 B Z
Notes:
Paint

Mounting

Series

1
LM LuxMaster
Shoebox,
Medium

P
W
K
M
Y
T
1
2

Square Pole 12 Arm


Wall Bracket 12 Arm
Adjustable Knuckle
External Fitter
Yoke Mount
Square Tenon
Square Tenon 2 Arms 90
Square Tenon 2 Arms 180

3
4
5
6
7
8
9
R

Square Tenon 3 Arms 90


Square Tenon 4 Arms 90
Round Tenon
Round Tenon 2 Arms 90
Round Tenon 2 Arms 180
Round Tenon 3 Arms 90
Round Tenon 3 Arms 120
Round Tenon 4 Arms 90

Paint3
BZ Bronze
(standard)
BK Black
GY Gray
WH White

2
3

Voids UL/CSA Certified options and


not available in MT, TT, and
DT voltages
PC & SH not available with
NR option
Other colors available, please
contact your local American Electric
Lighting representative

Product Guide

143

Accessories
Mounting Hardware
O R D E R I N G

D ATA

Catalog
Number

Item

Approx
Wt. (lbs)

Area Rectilinear Arm


Field Installed

53-1-BZ1
153-1-BZ1

2-1/2

A
B
C
D
2.031
2.781 3.25
8
2.031
3.531
4
10
NOTE: Pole must be drilled to match dimensions shown

32
46

Area Wall Mount Bracket


C

53-1-W-BZ1
153-1-W-BZ1

A
B
C
D
5.687
4.687 2.781 2.031
5.687
4.687 3.531 2.031
NOTE: Pole must be drilled to match dimensions shown

32
46

Round Pole Mounting

12-1/2"

53-1-BZ-WM1
153-1-BZ-WM1

Pole Mount Comes with Rectilinear Arm.

Product Guide

7
5

53-VS

Polycarbonate Shield
For flat lens only.

RKASA-EF-BZ1
RKPEM-EF-BZ1
RKPES-EF-BZ1

Mast Arm FItter


ASA External Mast Arm FItter
PEM External Mast Arm FItter
PES External Mast Arm FItter

Series ASA
Series PEM
Series PES

5
5
5

ASA R2/3/5 HS
ASA R4 HS
PEM R2/R3 HS
PES R2/R3 HS
LS-HS-BZ
LM-HS-BZ
AVL-EHS-BZ

House-Side Shield
ASA Internal for R2, R3, R5 Reflectors
ASA Internal for R4 Reflectors
PEM Internal for R2, R3, R5 Reflectors
PES Internal for R2, R3, R5 Reflectors
LS External, Bronze
LM External, Bronze
AVL External, Bronze

Series 53
Series 153
Series PEM
Series PES
Series LS
Series LM
Series AVL

5
5

Notes:
1 Standard finish is dark bronze. For other finishes change BZ to BK (black) or WH (white)

144

Series 53
Series 153

For more information please visit our website:


www.americanelectriclighting.com

5
5
5

Accessories
Mounting Hardware
AVA I L A B I L I T Y

53

153

AVL

LS

LM

ASA

53-1-BZ

153-1-BZ

53-1-W-BZ

153-1-W-BZ

53-1-BZ-WM

153-1-BZ-WM

9401-H

9401-H

9401-G

9401-G

RK53-HS-SHLD

RK153-HS-SHLD

AVL EHS BZ

LS-HS

LM-HS-BZ

See chart below

See chart below

See chart below

See chart below

PES

PEM

VMR

VLR

PES-HS-BZ1

PEM-HS-BZ1

VMR-EHS-BZ1

VLR-EHS-BZ1

See chart below

See chart below

See chart below

See chart below

See chart below

See chart below

See chart below

See chart below

Rectilinear Arm, Dark Bronze


Wall Mount Bracket, Dark Bronze
Round Pole Mounting, Dark Bronze
Single-Arm Steel Bracket, Dark Bronze
Single-Arm Steel Bracket, Galvanized
House-Side Shield, Dark Bronze
4-1/4 Pole Top Tenon Adapter, Dark Bronze
4-7/8 Pole Top Tenon Adapter, Dark Bronze

Rectilinear Arm, Dark Bronze


Wall Mount Bracket, Dark Bronze
Round Pole Mounting, Dark Bronze
Single-Arm Steel Bracket, Dark Bronze
Single-Arm Steel Bracket, Galvanized
House-Side Shield, Dark Bronze
4-1/4 Pole Top Tenon Adapter, Dark Bronze
4-7/8 Pole Top Tenon Adapter, Dark Bronze

NOTES:
1 For R2 and R3 optics only
Standard finish is dark bronze, contact American Electric Lighting for other finishes

Pole Top Tenon Adapters1


Drill Pattern

1@90

2@90

3@90

4@90

2@180

3@120

Standard 4-1/4

TMS-20-190

TMS-20-290

TMS-20-390

TMS-20-490

TMS-20-280

TMS-20-320

Optional 4-7/8

T47-20-490

Standard 4-1/4

TMS-25-190

TMS-25-290

TMS-25-390

TMS-25-490

TMS-25-280

TMS-25-320

Optional 4-7/8

T47-25-490

Mounting Pattern 2-3/8 OD Tenon

Mounting Pattern 2-7/8 OD Tenon

NOTES:
1 For use with AVL and ASA only

Product Guide

145

Accessories
Steel Bracket - Prime Coated
(For Horizontally Mounted Luminaires)

M O U N T I N G

Catalog
Number
9401

O P T I O N S

Item
FABRICATED STEEL BRACKET SINGLE ARM
For mounting on 2'' (23/8'' OD) standard pipe or pole
top tenon. 12'' spread.

Effective
Projected
Area (Sq. Ft.)

Approx.
Wt. (Lbs.)

.4

10

See Isotach Wind Map, page 189

Note: Above brackets available with Galvanized Finish. To order add -G suffix to catalog number.

146

Product Guide

For photometric information please visit our website:


www.americanelectriclighting.com

Accessories
M
M OO UU NN TT II NN GG OO PP TT II OO NN SS

Pole Mount, secured with solid steel


plate, attaches luminaire directly to
square pole. Full length mounting screws
secure luminaire, arm and pole.
Catalog Number - LMPBZ
Wall Mount Arm secures luminaire to
wall plate with full length mount screws.
Full length mounting screws secure
luminaire to arm and wall plate.

Square/round Tenon Adapter mounts


on top of round or square pole for
luminaire attachment. Makes a
smooth transition from pole to
luminaire. Available mounting
arrangements listed below.
Catalog Number - LM5BZ

Catalog Number - LMWBZ


Adjustable Knuckle for pole attachment
of luminaire. Makes a smooth transition
from pole to luminaire.

Wraparound Yoke - Luminaire is


suspended above mounting surface by
mount and extends above poles.
Catalog Constructable Option

Catalog Number - LMKBZ


Catalog Number - LMGBZ
Catalog Number

Description

LMTBZ
LM1BZ
LM2BZ
LM3BZ
LM4BZ
LM5BZ
LM6BZ
LM7BZ
LM8BZ
LM9BZ
LM0BZ

Square Tenon with 1 Arm


Square Tenon with 2 Arms at 90
Square Tenon with 2 Arms at 180
Square Tenon with 3 Arms
Square Tenon with 4 Arms
Round Tenon with 1 Arm
Round Tenon with 2 Arms at 90
Round Tenon with 2 Arms at 180
Round Tenon with 3 Arms at 90
Round Tenon with 3 Arms at 120
Round Tenon with 4 Arms at 90

Mast Arm Mount - Luminaire is


attached to curved mast arm for
mounting to pole or structure.
Catalog Number - LMMBZ

Product Guide

147

Area Lighting
B A L L A S T

M AT R I C E S

ASA
Watts
07S
07M
10S
10M
13S
14S
15S
15M
17M
20S
23S
25S
23M
25M
31S
40S
40M

120
CA,CT,RH,RN
XH,XN
CA,CT,RH,RN
CA,XH,XN
RH,RN
RH,RN
CA,CT,RH,RN
XH,XN
CA
CA
CA
CA,XH,XN
CA
CA,SC
CA
CA,CT
CA,CT,SC

208
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,CT
CA,SC

240
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA,RH,RN
CA
CA,XH,XN
CA
CA,SC
CA
CA,CT
CA,CT,SC

MT7
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

TT3
CT,XH,XN
XH,XN
CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA,CT
CA,CT
-

5T4
CA
CA
CA
CA

120
CA,CT,RH,RN
XH,XN
CA,CT,RH,RN
CA,XH,XN
RH,RN
RH,RN
CA,CT,RH,RN
XH,XN
CA
SC
CA

208
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC
CA

240
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC
CA

TT3
CT,XH,XN
XH,XN
CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC
CA

5T4
-

277
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
CA,XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,CT
CA,SC

347
XH,XN
XH,XN
CT,XH,XN
XH,XN
XH,XN
CA
CA
CA,CT,SC
CA
-

480
XH,XN
CA,XH,XN
CA,XH,XN
CA
CA
CA
CA,SC
CA
CA
CA,SC

DT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
XH,XN
CA
CA
CA
CA,XH,XN
CA
CA,CT,SC
CA
CA,CT
CA,CT

MT1
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

MT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

277
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
CA,XH,XN
CA,CT,XH,XN
XH,XN
CA
SC
CA

347
XH,XN
XH,XN
CT,XH,XN
XH,XN
XH,XN
CA
SC
CA

480
XH,XN
CA,XH,XN
CA,XH,XN
CA
SC
CA

DT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
XH,XN
CA
SC
CA

MT1
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC
CA

MT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC
CA

ASA continued
Watts
07S
07M
10S
10M
13S
14S
15S
15M
17M
20S
23S
25S
23M
25M
31S
40S
40M

PES
Watts
07S
07M
10S
10M
13S
14S
15S
15M
17M
20M
25M

PES continued
Watts
07S
07M
10S
10M
13S
14S
15S
15M
17M
20M
25M

148

MT7
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC
CA

Product Guide

For photometric information please visit our website:


www.americanelectriclighting.com

Area Lighting
B A L L A S T

M AT R I C E S

PEM
Watts
20S
23S
25S
23M
25M
31S
32M
35M
40S
40M

120
CA
CA
CA,XH,XN
CA
CA,SC
CA
SC
SC
CA,CT
CA,CT,SC

208
CA
CA
CA
CA
CA,SC
CA
SC
SC
CA,CT
CA,SC

240
CA,RH,RN
CA
CA,XH,XN
CA
CA,SC
CA
SC
SC
CA,CT
CA,CT,SC

MT7
CA
CA
CA
CA
CA,SC
CA
SC
SC
CA,SC

TT3
CA
CA,CT
CA,CT
SC
SC
-

5T4
CA
CA
CA
CA

120
CA,CT,RH,RN
CA,CT,RH,RN
CA,XH,XN
RH,RN
RH,RN
CA,CT,RH,RN
XH,XN
CA
SC

208
CA,CT,XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC

240
CA,CT,XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC

TT3
CT,XH,XN
CT,XH,XN
XH,XN
XH,XN
CA
SC

5T4
-

277
CA
CA
CA
CA
CA,SC
CA
SC
SC
CA,CT
CA,SC

347
CA
CA,CT,SC
SC
SC
CA
-

480
CA
CA
CA,SC
CA
SC
SC
CA
CA,SC

DT2
CA
CA
CA,XH,XN
CA
CA,CT,SC
CA
CA,CT
CA,CT

MT1
CA
CA
CA
CA
CA,SC
CA
SC
SC
CA,SC

MT2
CA
CA
CA
CA
CA,SC
CA
SC
SC
CA,SC

277
CA,CT,XH,XN
CA,CT,XH,XN
CA,XH,XN
CA,CT,XH,XN
XH,XN
CA
SC

347
XH,XN
CT,XH,XN
XH,XN
XH,XN
CA
SC

480
XH,XN
CA,XH,XN
CA,XH,XN
CA
SC

DT2
CA,CT,XH,XN
CA,CT,XH,XN
XH,XN
XH,XN
CA
SC

MT1
CA,CT,XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC

MT2
CA,CT,XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC

PEM continued
Watts
20S
23S
25S
23M
25M
31S
32M
35M
40S
40M

VMR
Watts
07S
10S
10M
13S
14S
15S
15M
17M
20M

VMR continued
Watts
07S
10S
10M
13S
14S
15S
15M
17M
20M

MT7
CA,CT,XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
SC

Product Guide

149

Area Lighting
B A L L A S T

M AT R I C E S

VLR
Watts
23S
23M
25S
25M
31S
40S
40M
45M
75M
X1S
X1M

120
CA
CA
CA,XH,XN
CA,SC
CA
CA,CT
CA,CT,SC
CA,CT,SC
CA
CA
CA,SC

208
CA
CA
CA
CA,SC
CA
CA,CT
CA,SC
CA,SC
CA
CA
CA,SC

240
CA
CA
CA,XH,XN
CA,SC
CA
CA,CT
CA,CT,SC
CA,CT,SC
CA
CA
SC

TT3
CA,CT
CA,CT
CA

5T4
CA
CA
CA
CA
CA
CA

277
CA
CA
CA
CA,SC
CA
CA,CT
CA,SC
CA,CT,SC
CA
CA
CA,SC

347
CA
CA,CT,SC
CA
CA
CA

480
CA
CA,SC
CA
CA
CA,SC
CA,SC
CA
CA

DT2
CA
CA
CA,XH,XN
CA,CT,SC
CA
CA,CT
CA,CT
CA,CT,SC
CA
CA
CA,SC

MT1
CA
CA
CA
CA,SC
CA
CA,SC
CA,CT,SC
CA
CA
CA,SC

277
CA
CA,SC
CA
SC
SC
CA
CA,SC
SC
SC
CA
CA,CT,SC

347
CA
SC
SC
SC
CA,CT
CA,CT,SC
SC
SC
CA
CA,CT

480
CA
CA
CA
SC
SC
CA
CA,SC
SC
SC
CA
SC

DT2
CA, CT
SC
CA
SC
SC
CA
CA,SC
SC
CA
CA

DT4
CT
-

VLR continued
Watts
23S
23M
25S
25M
31S
40S
40M
45M
75M
X1S
X1M

MT7
CA
CA
CA
CA,SC
CA
CA,SC
CA,CT,SC
CA
CA
CA,SC

AVL and AVL BIA


Watts
25S
25M
31S
32M
35M
40S
40M
45M
75M
1XS
1XM

120
CA
CA,SC
CA
SC
SC
CA
CA,SC
SC
SC
CA
CA,SC

208
CA
CA,SC
CA
SC
SC
CA
CA,SC
SC
SC
CA,CT
CA,SC

240
CA
CA,SC
CA
SC
SC
CA
CA,SC
SC
SC

AVL and AVL BIA continued


Watts
25S
25M
31S
32M
35M
40S
40M
45M
75M
1XS
1XM

150

MT1
CA
CA,SC
CA
SC
SC
CA
CA,SC
SC
CA
CA,SC

Product Guide

MT2
CA
CA,SC
CA
SC
SC
CA
CA,SC
SC
CA
CA,SC

MT7
CA
CA,SC
CA
SC
SC
CA
CA,SC
SC
CA
CA, SC

TT7
CA
SC
SC
SC
CA,CT
CA,SC,CT
SC
CA
CA

For photometric information please visit our website:


www.americanelectriclighting.com

MT2
CA
CA
CA
CA,SC
CA
CA,SC
CA,CT,SC
CA
CA
CA,SC

Area Lighting
B A L L A S T

M AT R I C E S

LuxMaster Series 53
Watts
07S
07M
10S
10M
13S
14S
15S
15M
17M

120
CA,CT,RH,RN
XH,XN
CA,CT,RH,RN
CA,XH,XN
RH,RN
RN,RH
CA,CT,RN,RH
XH,XN
CA

208
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA

240
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA

277
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
CA,XH,XN
CA,CT,XH,XN
XH,XN
CA

347
XH,XN
XH,XN
CT,XH,XN
XH,XN
XH,XN
CA

480
XH,XN
CA,XH,XN
CA,XH,XN
CA

DT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
XHX,XN
CA

LuxMaster Series 53 continued


Watts
07S
07M
10S
10M
13S
14S
15S
15M
17M

MT1
CA,CT,XN,XH
XN,XH
CA,CT,XN,XH
XH,XN
CA,CT,XH,XN
XH,XN
CA

MT2
CA,CT,XN,XH
XH,XN
CA,CT,XH.XN
XH,XN
CA,CT,XH.XN
XH,XN
CA

MT7
CA,CT,XN,XH
XN,XH
CA,CT,XN,XH
XH,XN
CA,CT,XH.XN
XH,XN
CA

TT3
CT,XN,XH
XN,XH
CT,XN,XH
XH,X
XH,XN
CA

LuxMaster Series 153


Watts
20S
23S
23M
25S
25M
31S
40S
40M

120
CA
CA
CA
CA,XH,XN
CA,SC
CA
CA,CT
CA,CT,SC

208
CA
CA
CA
CA
CA,SC
CA
CA,CT
CA,SC

240
CA,RH,RN
CA
CA
CA,XH,XN
CA,SC
CA
CA,CT
CA,CT,SC

277
CA
CA
CA
CA
CA,SC
CA
CA,CT
CA,SC

347
CA
CA,CT,SC
CA
-

480
CA
CA
MR
CA
CA
CA,SC

DT2
CA
CA
CA
CA,XH,XN
CA,CT,SC
CA
CA,CT
CA,CT

LuxMaster Series 153 continued


Watts
20S
23S
23M
25S
25M
31S
40S
40M

MT1
CA
CA
CA
CA
CA,SC
CA
CA,SC

MT2
CA
CA
CA
CA
CA,SC
CA
CA,SC

MT7
CA
CA
CA
CA
CA,SC
CA
CA,SC

TT3
CA
CA,CT
CA,CT
-

Product Guide

151

Area Lighting
B A L L A S T

M AT R I C E S

LuxMaster Classic Series LS


Watts
03S
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M

120
RN
RH,RN
CA,CT,RH,RN
XH,XN
CA,CT,RH,RN
CA,XH,XN
RH,RN
RH,RN
CA,CT,RH,RN
XH,XN
CA

208
CA,CT,XH,XN
XH,XN
CA,CT,XN,XH
XH,XN
CA,CT,XN,XH
XN,XH
CA

240
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA

277
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
CA,XH,XN
CA,CT,XH,XN
XH,XN
CA

347
XH,XN
XH,XN
CT,XH,XN
XH,XN
XH,XN
CA

480
XH,XN
CA,XH,XN
CA,XH,XN
CA

DT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
XH,XN
CA

LuxMaster Classic Series LS continued


Watts
03S
05S
07S
07M
10S
10M
13S
14S
15S
15M
17M

MT1
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA

MT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA

MT7
CA,CT,XH,XN
XH,XN
CA,CT,XN,XH
XH,XN
CA,CT,XH,XN
XH,XN
CA

TT3
CT,XH,XN
XH,XN
CT,XH,XN
XH,XN
XH,XN
CA

LuxMaster Classic Series LM


Watts
07S
07M
10S
10M
13S
14S
15S
15M
17M
20S
23S
25S
23M
25M
31S
40S
40M

120
CA,CT,RH,RN
XH,XN
CA,CT,RH,RN
CA,XH,XN
RH,RN
RH,RN
CA,CT,RH,RN
XH,XN
CA
CA
CA
CA,XH,XN
CA
CA,SC
CA
CA,CT
CA,CT,SC

208
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,CT
CA,SC

240
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA,RH,RN
CA
CA,XH,XN
CA
CA,SC
CA
CA,CT
CA,CT,SC

277
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
CA,XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,CT
CA,SC

347
XH,XN
XH,XN
CT,XH,XN
XH,XN
XH,XN
CA
CA,CT
CA,CT,SC
CA
-

480
XH,XN
CA,XH,XN
CA,XH,XN
CA
CA
CA
CA,SC
CA
CA
CA,SC

LuxMaster Classic Series LM continued


Watts
07S
07M
10S
10M
13S
14S
15S
15M
17M
20S
23S
25S
23M
25M
31S
40S
40M

152

MT7
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

Product Guide

TT3
CT,XH,XN
XH,XN
CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA,CT
CA,CT
-

5T4
CA
CA
CA
CA

For photometric information please visit our website:


www.americanelectriclighting.com

DT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
XH,XN
CA
CA
CA
CA,XH,XN
CA
CA,CT,SC
CA
CA,CT
CA,CT

MT1
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

MT2
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA,CT,XH,XN
XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

FLOODLIGHTING
ACP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154
UltraFlood Series 75 . . . . . . . . . . . . . . . . . . . .156
UltraFlood Series 77 . . . . . . . . . . . . . . . . . . . . .158
Energy Saver Series CES . . . . . . . . . . . . . . . . . .160
Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . .162
Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . .163
AmeriSport Series ASP . . . . . . . . . . . . . . . . .164
Sportslighting Series SPF . . . . . . . . . . . . . . . . .166
Options & Accessories . . . . . . . . . . . . . . . . . . . .168
Ballast Matrices . . . . . . . . . . . . . . . . . . . . . .173-174

American Electric Lighting

153

ACP Series
American Compact Floodlight
70-400W HPS; 175-400W MH

P R O D U C T

O V E R V I E W

NEW

Features:
NEMA beam patterns available in a variety of options
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Door is hinged and easily removable for quick maintenance
Fully pivoting painted wraparound yoke is standard, tenon and galvanized yoke
mounting options are available for precise aiming
UL listing is standard @ 40 ambient
For easy maintenance, tool-less entry is available
Standardized hardware for single-tool internal maintenance
Suitable for -40C to 40C HPS / -30C to 40C MH
Lens is thermal shock and impact resistant tempered flat glass
Approved for use in 1.5 G vibration applications

Applications:
Auto dealerships
Schools
Construction sites
Recreational areas
Churches

Industrial sites
Shopping centers
Parking lots
Substations
Building facades

DIMENSIONS

All electrical components warranted by American Electric Lighting's 6-year


guarantee

PREFERRED SELECTION CATALOG NUMBERS

ACP 15S RN 120 76 EC NL TL


ACP 23S CA MT1 76 EC 0643 TL NL
ACP 40M SC MT7 76 TM TL
ACP 40M SC MT1 76 LC 0443 TL PC
ACP 40M SC MT1 76 0443 TL NL
ACP 40S CA MT1 76 EC LC 0443 TL PC

Effective Projected Area (EPA)


The EPA for the ACP Series is 1.60 sq. ft.
Approx. Wt. = 35 lbs.

154

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

ACP Series
American Compact Floodlight
70-400W HPS; 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: A C P 4 0 M C A M T 1 7 6 0 4 4 3 L C T L P C

Series
ACP American
Compact
Flood

Wattage / Source
07
10
15
17
20
25
31
40
23

70W
100W
150W
175W1
200W2
250W
310W2
400W
250/400W
Wired 250W3
24 250/400W
Wired 400W2, 3

S HPS
M MH

Voltage

Ballast
RN Reactor Normal
Power Factor4
RH Reactor High
Power Factor4
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA (Auto Reg)
CT CWI

120
208
240
277
347
480
MT1
MT2
MT7
TT3
5T4

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
5-tap Wired 480V

NEMA Beam Pattern

55
66
76

5H x 5V1
6H x 6V
7H x 6V

Refer to the ballast matrix on


page 173 for compatibility.

Options
Lamp
Mounting5
LC Lamp Included, Clear
(blank) Wraparound Yoke Mount (standard)1
LD Lamp Included, Deluxe
YG Wraparound Yoke Galvanized
TM Tenon Slipfitter
Fusing7
SF Single Fuse (120, 277, 347V)
Paint6
DF Double Fuse (208, 220, 240, 480V)
(blank) Bronze (standard)
BK Black
Cord Type*
Cord Length*
GY Gray
04
4
63 16-3
WH White
05
5
44 14-48
06
6
43 14-3
Terminal Block
08
8
23 12-3
(blank) Terminal Block Factory Wire
10
10
T2 Wired to L1 and L2 Position
*Cord length and type
12
12
T3 3 Wire Operation
should be combined to
15
15
(L1, N, L2 Position)
form one number.
20
20
Ex: 0423
25
25
Listing
30
30
(blank) UL Listed (standard)
CS CSA Certified
Misc.
XL No Listing
TL Tool-less Entry
PC Photocontrol Included per
Photocontrol Receptacle
Voltage Specified
(blank) Photocontrol Receptacle (standard)
5H 50 Hertz Ballast Frequency9
NR No PEC Receptacle
NL NEMA Label
Starter2
(blank) Open Board (standard)
OP Open Board Plug-in
EC Encapsulated Plug-in

Notes:
1 MH only
2 HPS only
3 Available in CA ballast option only
4 Available in 120V for 50-150W HPS, 220 to 240V only
available for 200-400W HPS; not available in MH
5 Painted to match fixture
6 Other colors available, please contact your local
American Electric Lighting representative
7 Not available in multi-tap ballast options
8 For 3-wire operation and ground
9 Limited availability, please contact your local American
Electric Lighting representative

Product Guide

155

UltraFlood Series 75
Heavy Duty Floodlight
100-400W HPS; 175-400W MH

P R O D U C T

O V E R V I E W

Features:
NEMA beam patterns available in a variety of options including horizontal
and vertical lamps
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Door is hinged and easily removable for quick maintenance
Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting
options are available for precise aiming
UL listing is standard
For easy of maintenance, tool-less entry and ballast tray are available options
Lens is thermal shock and impact resistant tempered glass
Hydroformed reflector
Suitable for -30C MH / -40C HPS

Applications:
Auto dealerships
Schools
Construction sites
Recreational areas
Storage yards
Office Buildings
Airports

Churches
Industrial sites
Shopping centers
Parking lots
Substations
Building facades

DIMENSIONS
Yoke Mount

All electrical components warranted by American Electric Lighting's 6-year


guarantee

PREFERRED SELECTION CATALOG NUMBERS

75 40M SC MT1 66 0443 TL NL


75 40S CA MT1 76 EC 0443 TL NL
75 40S CA MT1 76 TM EC TL NL
75 40M SC MT1 76 TM TL NL
75 25S CA MT1 76 EC 0443 TL NL
75 25S CA MT1 76 TM EC TL NL

Vertical Tenon Mount

Effective Projected Area (EPA)


The EPA for the UltraFlood Series 75 is 2.75 sq. ft.
Approx. Wt. = 37 lbs.

156

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

UltraFlood Series 75
Heavy Duty Floodlight
100-400W HPS; 175-400W MH

O R D E R I N G

I N F O R M AT I O N

Example: 7 5 4 0 M C A M T 1 6 6 0 6 4 3 L C T L P C

Series
75 UltraFlood

Wattage / Source
10
15
17
20
25
31
40
23

100W
150W
175W
200W
250W
310W
400W
250/400W
Wired 250W
24 250/400W
Wired 400W

S HPS
M MH

RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA (Auto Reg)
CT CWI
SC SCWA
MR Mag Reg (3 Coil)

Refer to the ballast matrix on


page 173 for compatibility.

NEMA Beam Pattern

Voltage

Ballast
120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
Wired 240V
DT4 Dual Tap 240/480
Wired 480V
5T4 5-tap Wired 480V

Vertical Lamp
76 7H x 6V
66 6H x 6V
Horizontal Lamp
H6 6H x 6V
Refer to Optic
Distribution Matrix
below for compatibility.

Options
Mounting
(blank) Yoke Mount (standard)1
YG Wraparound Yoke Galvanized
TM Tenon Slipfitter1
Paint2
(blank)
BK
GY
WH

Bronze (standard)
Black
Gray
White

Terminal Block3
(blank) Hard wired (standard)
TB Terminal Block Factory Wire
T2 Wired to L1 and L2 Position
T3 3 Wire Operation
(L1, N, L2 Position)10
Listing
(blank)
CS
XL

UL Listed (standard)
CSA Certified
No Listing

Photocontrol Receptacle
(blank) Photocontrol Receptacle (standard)
NR No Photocontrol Receptacle4
Starter5
(blank) Open Board (standard)
EC Encapsulated plug-in
OP Open board plug-in

Lamp
LC
LD
Fusing6
SF
DF

Lamp Included, Clear


Lamp Included, Deluxe
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)

Cord Length*
04
4
05
5
06
6
08
8
10
10
12
12
15
15
20
20
25
25
30
30
Misc.
TL
PC
BT
SS
5H
NL
PGS
SH

Cord Type*
63 16-3
44 14-47
43 14-3
23 12-3
*Cord length and type should
be combined to form one
number. Ex: 0423

Tool-less Entry
Photocontrol Included per
Voltage Specified4
Removable Ballast
Stainless Steel fastener (external)
50 Hertz Ballast Frequency8
NEMA Label
Ballistic Shield9
Shorting Cap4

Notes:
1 Painted to match fixture
2 Other colors available, please contact your local
American Electric Lighting representative
3 Voids UL and CSA Listing
4 PC, and SH not available with NR option
5 HPS only
6 Voids UL and CSA listing, not available in MT, TT, and DT
voltages
7 For 3-wire operation and ground
8 Limited availability, please contact your local
American Electric Lighting representative
9 Ships separately
10 Not available in 120V

Optic Distribution
10S
15S
20S
25S
40S
17M
25M
40M

76
N
N
N
N
N
N
N
N

66
-

N
N
N

H6
N
N
N
N
N
N
N
N

Product Guide

157

UltraFlood Series 77
Heavy Duty Floodlight
400-1000W HPS; 400-1000W MH

P R O D U C T

O V E R V I E W

Features:
NEMA beam patterns available in a variety of options with horizontal lamp
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance
Door is hinged and easily removable for quick maintenance
Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting
options are available for precise aiming
UL listing is standard
For easy maintenance, tool-less entry is available
Suitable for -30C MH / -40C HPS
Lens is thermal shock and impact resistant tempered glass
All electrical components warranted by American Electric Lighting's 6-year
guarantee

Applications:
Auto dealerships
Schools
Churches
Industrial sites

Shopping centers
Parking lots
Substations
Building facades

DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

77 X1M CA MT1 76 0443 TL NL


77 X1M CA MT1 76 TM TL NL
77 X1S CA MT1 76 0443 TL NL
77 X1S CA MT1 76 TM TL NL

Effective Projected Area (EPA)


The EPA for the UltraFlood Series 77 is 3.97 sq. ft.
Approx. Wt. = 65 lbs.

158

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

UltraFlood Series 77
Heavy Duty Floodlight
400-1000W HPS; 400-1000W MH

O R D E R I N G

I N F O R M AT I O N

Example: 7 7 X I M C A M T 7 7 6 T M

Wattage / Source

Series
77 UltraFlood

40 400W
75 750W
X1 1000W

Voltage

Ballast

S HPS
M MH

CA CWA (Auto Reg)

Refer to the ballast matrix on


page 174 for compatibility.

NEMA Beam Pattern

120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240
wired 240
5T4 5 Tap Wired 480V

Horizontal Lamp
65 6H x 5V
66 6H x 6V
76 7H x 6V

Refer to optic
distribution matrix
below for compatibility.

Options
Mounting
(blank) Yoke Mount (standard)1
YG Yoke Galvanized
TM Tenon slipfitter1
Paint2
(blank)
BK
GY
WH

Bronze (standard)
Black
Gray
White

Terminal Block3
(blank) Hard wired (standard)
TB Terminal Block
T2 Wired to L1 and L2
T3 3 Wire Operation
(L1, N, L2 Position)8
Listing
(blank)
CS
XL

UL Listed (standard)
CSA Certified
No Listing

Photocontrol Receptacle
(blank) Photocontrol Receptacle
NR No Photocontrol Receptacle4
Lamp
LC
LD

Fusing5
SF
DF

Notes:
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)

Cord Length*
04 4
05 5
06 6
08 8
10 10
12 12
15 15
20 20
25 25
30 30
Misc.
TL
PC
SS
5H
NL
SH

Cord Type*
63 16-3
44 14-46
43 14-3
23 12-3
PW Pre-wire (Slip fitter only)
*Cord length and type should
be combined to form one
number. Ex: 0643

Tool Less Entry


Photocontrol Included per
Voltage Specified4
Stainless Steel fasteners (external)
50 Hertz Ballast Frequency7
NEMA Label
Shorting Cap4

1 Painted to match fixture


2 Other colors available, please contact your local
American Electric Lighting representative
3 Voids UL and CSA certification
4 PC, and SH not available with NR option
5 Voids UL and CSA listing, not available in MT, TT, & DT
voltages
6 For 3-wire operation and ground
7 Limited availability, please contact your local
American Electric Lighting representative
8 Not available in 120V

Optic Distribution
X1S
X1M

65
N
-

66
N
-

76
N

Lamp Included, Clear


Lamp Included, Deluxe

Product Guide

159

Energy Saver Series CES


Floodlight
35-150W HPS; 50-175W MH

P R O D U C T

O V E R V I E W

Features:
Durable polyester powder paint finish
Die-cast aluminum housing
Fully gasketed
Lens secured by hinged, captive bezel with captive screw or NEMA latch
closure
High efficiency aluminum reflector
Provides broad floodlighting coverage
Impact and thermal resistant tempered glass lens
UL listing in standard

Applications:

PREFERRED SELECTION CATALOG NUMBERS

Waterfront areas
Building facades
Residential areas
Recreational areas
Commercial environments
Parking areas
Industrial sites
Storage areas

CES 15S RN 120 LC

DIMENSIONS

Effective Projected Area (EPA)


The EPA for the Energy Saver Series CES is 0.61 sq. ft.
Approx. Wt. = 18 lbs.

160

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Energy Saver Series CES


Floodlight
35-150W HPS; 50-175W MH

O R D E R I N G

I N F O R M AT I O N

Example: C E S 0 3 S C A 1 2 0 B K

Wattage / Source

Series
CES Compact
Energy Saver
Floodlight

03
05
07
10
15
17

35W
50W
70W
100W
150W
175W

S HPS
M MH

Refer to the ballast matrix on


page 174 for compatibility.

Ballast

Voltage

RN Reactor, Normal
Power Factor
RH Reactor, High
Power Factor
XN High Reactance (lag),
Normal Power Factor
XH High Reactance (lag),
High Power Factor
CA CWA (Auto Reg)

120 120V

Options
Mounting
(blank) 1/2 Threaded Knuckle Mount
WY Wrap Around Yoke

Lamp
(blank)
LC

None
Lamp Included, Clear

Paint
(blank)
BK
WH

Misc.
TL

Tool Less Entry

Bronze (standard)
Black
White

Photocontrol Receptacle
(blank) None
PC Button Photocontrol

Product Guide

161

Quartz Flood Series 570


Floodlight
500W Quartz

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance, bronze is standard color
Single door access to lamp and electrical components for quick, easy
installation and servicing
Suitable for -30C MH / -40C HPS
UL listing is standard
Lens is thermal shock and impact resistant tempered glass

570-61/L

Applications:
Transportation terminals
Building facades
Sports lighting
Parking lots
Industrial areas
Commercial areas
Residential areas
Security lighting

Fixture Available
570-61/L

DIMENSIONS

Effective Projected Area (EPA)


The EPA for the Floodlight, Series 570 is 0.72 sq. ft.
Approx Wt = 3.5 lbs

162

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Clear Lamp Included (120V)

Quartz Flood Series 474


Floodlight
1500W Quartz

P R O D U C T

O V E R V I E W

Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance, bronze is standard color
Single door access to lamp and electrical components for quick, easy
installation and servicing
Permanently attached bezel is secured by twin captive spring latches
UL listing is standard
Lens is thermal-, shock-, and impact-resistant tempered glass for lamp
protection

Applications:
Transportation terminals
Building facades
Sports lighting
Parking lots
Industrial areas
Commercial areas
Residential areas
Security lighting

Fixtures Available
474-61/L-208V M4 Lamp Included (208V)
474-61/L-240V M4 Lamp Included (240V)
474-61/L-277V M4 Lamp Included (277V)

DIMENSIONS

Effective Projected Area (EPA)


The EPA for the Floodlight, Series 474 is 1.13 sq. ft.
Approx Wt = 5.5 lbs

Product Guide

163

AmeriSport Series ASP


Sports Floodlight
400-1500W MH

W
PP RR OO DD UU CC TT OO VV EE RR VV II EE W

Features:
Two-piece die-cast aluminum ballast housing mounted to galvanized steel
trunnion. Ballast is removable and hinged with captive fastener. Steel trunnion
features vertical and horizontal aiming scale with vertical repositioning stop.
All external hardware is stainless steel.
White corrosion resistant polyester powder finish standard; other architectural
colors available.
Heavy-gauge anodized reflector with six distributions available. "Flux manager"
available for optimal glare and spill light control. Transverse mounting of lamp.
Lamp support included. Optical chamber sealed to inhibit entrance of
contaminants. Hinged lens is thermal-, shock- and impact-resistant tempered
glass. Lens frame is galvanized and secured by stainless steel spring clips for
servicing of lamp. US. Patent no. 6,190,023. Canada Patent no. 2,212,014.
Fixture mounted by securing trunnion directly to cross arm. Mounting
hardware provided.
Suitable for -30C MH / -40C HPS

Applications:

UL listed, suitable for wet locations. Below horizontal aiming orientation only.
Listed and labeled to comply with Canadian Standards.

Stadiums
Sports fields
Arenas
Tracks
Courts

All electrical components warranted by American Electric Lightings 6-year


guarantee.

DIMENSIONS

Effective Projected Area (EPA)


The EPA for the Sports Floodlight Series SPF is 3.3 sq. ft.
Approx. Wt. = 55 lbs.

164

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

AmeriSport Series ASP


Sports Floodlight
400-1500W MH

O R D E R I N G

I N F O R M AT I O N

Example: A S P X 5 M C A M T 1 G N

ASP AmeriSport

40 400W
X1 1000W
X5 1500W

M Metal
Halide

CA CWA
SC SCWA
(Pulse Start)1
CT CWI2

Optics

Voltage

Ballast

Wattage / Source

Series

120
208
240
277
347
480
MT1
MT2
MT7
TT3
5T8

120V
208V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 277V
5-tap Wired 480V

G General Purpose
H Heavy Duty

Distribution
N
M
W
NX

Narrow Beam
Medium Beam
Wide Beam
Narrow Beam with
Flux Manager
DX Medium Beam with
Flux Manager
WX Wide Beam with
Flux Manager

Options
Listing
(blank) UL Listed (standard)
CS CSA Certified3
XL No Listing
Fusing4
SF Single Fuse (120, 277, 347V)
DF Double Fuse (208, 220, 240, 480V)
Cord Length*
03 3' Cord
05 5' Cord
08 8' Cord

Cord Type*
23 12-3 SEO Cord
43 14-3 SEO Cord
63 16-3 SEO Cord

Frequency
5H 50 Hertz Ballast Frequency5
Filter
CF Charcoal Filter6
Connector
3P 3 Prong Plug7,8,9,10
Quartz Restrike
QS Quartz Restrike (Lamp not included)

Notes:
1 400W MH only
2 Available in 208 and 240V only
3 Consult factory for CSA availability
4 Single tap only
5 Limited availability, please contact your local
American Electric Lighting representative
6 Must use with heavy duty optical
7 Must use mating receptacle, provided by others
8 Not available with 1500W, 120V
9 Use with pre-wired gauges and cross-arms
10 For use with 0363 cord length and type only

*Cord length and type should


be combined to form one
number. Ex: 0523
Lamp
LC Lamp Included, Clear
(Ships separately)

Product Guide

165

Sportslighting Series SPF


Sports Floodlight
400W & 1000W HPS, 400W-1500W MH

P R O D U C T

O V E R V I E W

Features:
Heavy-gauge, hydroformed, aluminum ballast housing is mounted to integral
die-cast monoframe with horizontal degree aiming scale and repositioning
locator. Die-cast aluminum socket housing provides vertical aiming adjustment,
complete with degree aiming scale and repositioning stop.
Heavy-gauge, anodized, aluminum reflectors provide a range of NEMA beam
spreads. Optical chamber is sealed to inhibit entrance of contaminants. Hinged
lens is heavy-duty thermal shock and impact-resistant, tempered glass.
Adjustable mounting bracket standard. Porcelain, mogul-base socket with
copper alloy, nickel-plated screw shell and center contact. UL listed 1500W,
600V.
Fixture is mounted by securing the integral cross-arm mounting bracket directly
to the cross-arm. No additional adapters are required. A 5/8"-11UNC mounting
bolt is provided. Exposed bolt length is 1-1/2".
UL listed, suitable for wet locations. Listed and labeled to comply with Canadian
Standards.
Suitable for -30C MH / -40C HPS
Optional painted heavy duty reflector shroud available to protect the reflector.

Applications:

All electrical components warranted by AELs 6-year guarantee.

Stadiums
Sports fields
Arenas
Tracks
Courts
DIMENSIONS

PREFERRED SELECTION CATALOG NUMBERS

SPF X5M CA MT1 33


SPF X5M CA MT1 44
SPF X5M CA MT1 66

Dimensions
EPA:
NEMA 2,3:
NEMA 4,5,6:
Diameter: NEMA 2,3:
NEMA 4,5,6:
Length:
NEMA 2,3:
NEMA 4,5,6:
Weight:
53 lbs.

166

Product Guide

2.9 ft.2 (.27 m2)


2.5 ft2 (.23 m2)
23-1/8 (58.7)
21-1/2 (54.6)
30 (76.2)
31-1/2 (80)
24 Kg.

For photometric information, visit our website,


www.americanelectriclighting.com

Sportslighting Series SPF


Sports Floodlight
400W & 1000W HPS, 400W MH-1500W MH

O R D E R I N G

I N F O R M AT I O N

Example: S P F X 5 M C A M T 1 5 5

Wattage / Source

Series
SPF Sports
Floodlight

40 400W
X1 1000W
X5 1500W1

S HPS
M MH

Voltage

Ballast
120
208
220
240
277
347
480
MT1
MT2
MT7
5T4

CA CWA
SC SCWA (Pulse
Start)2
CT CWI3

120V
208V
220V
240V
277V
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
5-Tap Wired 480V

Optics
22
33
44
55
66

2H x 2V
3H x 3V
4H x 4V
5H x 5V
6H x 6V

Options
Listing
(blank) UL Listed (standard)
CS CSA Certified4
XL No Listing

Bolt
LB Extended Bolt for Wood Crossarm
Support
LT Lamp Support

Fusing5
SF Single Fuse (120, 277, 347V)
DF Double Fuse (208, 220, 240, 480V)

Connector
3P 3 Prong Plug8,9,10,11

Lamp
LC Lamp Included, Clear
(Ships separately)

Coating
TC Non-stick Protective Coating,
Black Only

Cord Length**
03 3' Cord
05 5' Cord
08 8' Cord

Cord Type**
23 12-3 SEO Cord
43 14-3 SEO Cord
63 16-3 SEO Cord
**Cord length and type
should be combined to form
one number. Ex: 0523

Frequency
5H 50 Hertz Ballast Frequency6
Shield
GS Glare Shield14
HG Hail Shroud and Glare shield
RS Reflector (Hail) Shroud7

Aiming
AH Above Horizontal
Filter
CF Charcoal Filter12

Notes:
1
2
3
4
4
5
6
7
8
9
10
11
12
13
14

Metal Halide only


400W MH Only
Available in 208 and 240V only. Not available in
HPS
Consult factory for CSA availability
Must use mating receptacle, provided by others
Available in single tap only
Limited availability, please contact your local
American Electric Lighting representative
Heavy duty anodized aluminum shroud
Must use mating receptacle, provided by others
Use with prewired caged and crossarms
For use with 0363 cord length and type only
Not available with 1500W, 120V
For use with reflector shroud (RS option) only
Lamp not included
LV and GS not compatible

Quartz
QS Quartz Restrike13
Paint
BK Black
WH White

Louver
LV Internal Louver14

Product Guide

167

Accessories
G L A R E

S H I E L D S

Catalog

Approx.
Wt. (Lbs.)

Number

Item

RK75 GS BZ
RK75 GS LARGE BZ

ULTRA FLOOD GLARE SHIELD


Manufactured of corrosion-resistant aluminum.
For use with Ultra Flood, series 75. Standard
finish is bronze.
POLYCARBONATE VANDAL SHIELD

.6

ULTRA FLOOD GLARE SHIELD


Manufactured of corrosion-resistant aluminum.
For use with Ultra Flood, series 77. Standard
finish is bronze.
POLYCARBONATE VANDAL SHIELD

.7

.5

RKACP VS

COMPACT FLOOD GLARE SHIELD


Manufactured of corrosion-resistant aluminum.
For use with series 51. Standard
finish is bronze.2
COMPACT FLOOD VANDAL SHIELD

75 PGS 40W
77 PGS X1W
ACP PGS 40W

75 SERIES BALLISTIC SHIELD, 400W MAX


77 SERIES BALLISTIC SHIELD, 1000W MAX
ACP SERIES BALLISTIC SHIELD, 400W MAX

RK75 VS

RK77 GS BZ
RK77 GS LARGE BZ

RK77 VS

RKACP GS BZ
RKACP GS LARGE BZ

168

Effective
Projected
Area (Sq. Ft.)

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Accessories
For Mounting to Wood Poles
S T E E L
Catalog
Number

M O U N T I N G

Item

B R A C K E T S

Effective
Projected
Area (Sq. Ft.)

Approx.
Wt. (Lbs.)

9201

SINGLE UNIT BRACKET Manufactured of 2'' steel


pipe with a minimum yield of 35,000 PSI.
Requires two 1/2'' lag screws, one 5/8'' through-bolt
and one 2'' square flat washer. Prime coated finish.

.7

9254

SINGLE UNIT BRACKET Manufactured of 2'' steel


pipe with a minimum yield of 35,000 PSI.
Requires two 1/2'' lag screws, one 5/8'' through-bolt
and one 2'' square flat washer. Prime coated finish.

.7

13

9204

SINGLE UNIT BRACKET Fixture bracket is 3'' 3''- 5/16'' angle steel with 3/4'' - 11/2'' steel bolts. Unit of
2'' steel pipe with minimum yield strength of 35,000 PSI.
Requires two 1/2'' lag screws, one 5/8'' through-bolt
and one 2'' square flat washer. Prime coated finish.

.8

141/4

9205

TWIN UNIT BRACKET Each fixture bracket is 3'' 3''- 5/16'' angle steel with 3/4'' - 11/2'' steel bolts. Unit of
2'' steel pipe with minimum yield strength of 35,000 PSI.
Requires two 1/2'' lag screws, one 5/8'' through-bolt
and one 2'' square flat washer. Prime coated finish.

.8

271/4

9252
9252-G

TWIN UNIT BRACKET Manufactured of 2'' steel


pipe with a minimum yield strength of 35,000 PSI.
Requires two 1/2'' lag screws, one 5/8'' through-bolt
and one 2'' square flat washer. Prime coated finish.

1.4

24

THREE UNIT BRACKET Manufactured of 2'' steel


pipe with minimum yield strength of 35,000 PSI.
Requires two 1/2'' lag screws, one 5/8'' through-bolt
and one 2'' square flat washer. Prime coated finish.

1.9

27

(Galvanized)

9253
9253-G
(Galvanized)

NOTE: Above brackets available with GALVANIZED FINISH, to order add -G suffix to catalog number. (Example: 9252-G.)

Product Guide

169

Accessories
M O U N T I N G

Catalog
Number

170

A D A P T E R S

Item

Approx.
Wt. (Lbs.)

9902-H

ALUMINUM POLE-TOP MOUNT


Slipfitter mounting. Positive three-point mounting support and
corrosion-resistant hardware. Fits 2'' or 21/2'' pipe (2'' pipe intrudes
31/16'', 21/2'' pipe intrudes 23/4''.) Furnished with mounting bolts,
set screws, and compression fitting for cable entry.
Top cover removable for wiring.

9906

PIPE CLAMP MOUNT


Plated steel and cast aluminum clamp mount with corrosion-resistant
hardware for 11/2'' or 2'' pipe installations.

9909

PIPE CLAMP MOUNT


Plated steel and cast aluminum clamp mount with corrosion-resistant
hardware for 3'' pipe installations.

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

Accessories
For Mounting to Steel Poles
S T E E L

Catalog
Number

M O U N T I N G

Item

B R A C K E T S

Effective
Projected
Approx.
Area (Sq. Ft.) Wt. (Lbs.)

9333

THREE ARM POLE-BRACKET12'' spread, arms


@ 120 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons.
Prime coated finish.

1.2

34

9343

FOUR ARM POLE-TOP BRACKET48'' spread,


arms @ 90, 2'' (23/8'' OD) standard pipe tenon and
slipfitter base for mounting to standard 2'' pipe
tenons. Prime-coated finish.

.90

45

9352

TWO ARM POLE-TOP BRACKET 30'' spread, 2''


(23/8'' OD) standard pipe tenon and slipfitter base for
mounting to standard 2'' pipe tenons. Prime-coated
finish.

.87

21

9353

THREE ARM POLE-TOP BRACKET 30'' spread


between tenons, 2'' (23/8'' OD) standard pipe tenon
and slipfitter base for mounting to standard 2'' pipe
tenons. Prime-coated finish.

1.7

34

9354

FOUR ARM POLE-TOP BRACKET 30'' spread


between tenons, 2'' (23/8'' OD) standard pipe tenon
and slipfitter base for mounting to standard 2'' pipe
tenons. Prime-coated finish.

2.3

45

NOTE: Above brackets available with GALVANIZED FINISH, to order add -G suffix to catalog number. (Example: 9252-G)

For Steel, Aluminum, Fiberglass and Wood Poles Refer to the Pole Section or Call Your Local
American Electric Lighting Representative.

Product Guide

171

Options and Accessories


AVA I L A B I L I T Y

GLARE
SHIELDS

MOUNTING
BRACKETS

MOUNTING
ADAPTERS
POLE-TOP
MOUNTING
BRACKETS

SPORTS
FLOOD
ACCESSORIES

Flood Glare Shield, Dark Bronze


Large Flood Glare Shield, Dark Bronze
Upper Visor, Glass Lens and Glass Ring for NEMA 4, 5, 61
Upper Visor, Glass Lens and Glass Ring for NEMA 2, 31
Polycarbonate Vandal Shield
Ballistic Shield
Vertical Single Unit Bracket (19-3/4H) 4, 5
Vertical Single Unit Bracket (23H) 4, 5
Crossarm Single Unit Bracket 4, 6
Crossarm Twin Unit Bracket 4, 6
Vertical Twin Unit Bracket 4, 5
Galvanized Vertical Twin Unit Bracket 4, 5
Vertical Three Unit Bracket 4, 5
Galvanized Vertical Three Unit Bracket 4, 5
Aluminum Pole-Top Mount
Pipe Clamp Mount for 1-1/2 - 2 Pipe
Pipe Clamp Mount for 3 Pipe
Three-Arm Pole-Top Bracket (12 spread)
Two-Arm Pole-Top Bracket (30 spread)
Three-Arm Pole-Top Bracket (30 spread)
Four-Arm Pole-Top Bracket (30 spread)
Four-Arm Pole-Top Bracket (48 spread)
Crossarm Adapter
Crossarm Adapter, 45
Bottom Internal Louver, Glass Lens and Lens Ring for NEMA 4, 5, 6
Bottom Internal Louver, Glass Lens and Lens Ring for NEMA 2, 3
Radius Wall Bracket, Dark Bronze
Steel Angle Bracket, Dark Bronze
Mounting Bracket (for 2 Schedule 40 pipe)
Pole-Top Tenon Adapter for 2-3/8 to 2-7/8 OD Tenon
Wood Pole, 2-light
Wood Pole, 3-light
Wood Pole, 4-light

ACP

75

77

RKACP GS BZ

RK75 GS BZ

RK77 GS BZ

RKACP GS LARGE BZ

RK75 GS LARGE BZ

RK77 GS LARGE BZ

RKACP VS
ACP PGS 40W2
9201
9254
9204
9205
9252
9252-G
9253
9253-G
9902-H
9906
9909
9333
9352
9353
9354
9343

RK75 VS
75 PGS 40W2
9201
9254
9204
9205
9252
9252-G
9253
9253-G
9902-H
9906
9909
9333
9352
9353
9354
9343

RK77 VS
77 PGS X1W3
9201
9254
9204
9205
9252
9252-G
9253
9253-G
9902-H
9906
9909
9333
9352
9353
9354
9343

ASP
-

9/16" DIA.

ATS U
SPF TSU

Furnished with
weather-tight cord
grip for 14-3 SO cord.
(Grip for 12-3 SO optional.)

Wire
Access

ACRA45

ACRA

172

Product Guide

For photometric information, visit our website,


www.americanelectriclighting.com

SPF20 GS GL OPT U
SPF23 GS GL OPT U

ACRA
ACRA45 U

SPF20 LV GL U
SPF23 LV GL U
ARWB BZ U
ASAB BZ U

ASPMB OPT U
ATS U

Notes:
1 Louver and glare shield cannot be used simultaneously
2 400W lamp maximum
3 1000W lamp maximum
4 Brackets designed to accommodate fixtures with a maximum weight of 65 lbs. and an EPA of 4.0
5 Tenon mount only
6 Yoke mount only
Standard finish is dark bronze, contact American Electric Lighting for other finishes
ARWB BZ U

SPF
-

5/8" Clearance
Hole

SPFTS U
ACRW2
ACRW3
ACRW4

Floodlighting
B A L L A S T

ACRW2

M AT R I C E S

ACRW4

ACRW3

ASAB

APSMB OPT U

ACP Series
Watts
07S
10S
13S
14S
15S
17M
20S
23S
25S
23M
25M
31S
40S
40M

120
CA,CT,RH,RN
CA,CT,RH,RN
RH,RN
RH,RN
CA,CT,RH,RN
CA
CA
CA
XH,XN,CA
CA
CA
CA
CA,CT
CA,CT

208
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA
CA
CA,CT
CA

240
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
RH,RN,CA
CA
CA, XH, XN
CA
CA
CA
CA,CT
CA,CT

277
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA
CA
CA,CT
CA

347
XH,XN
CT,XH,XN
CA
CA
CA,CT,SC
CA
-

480
XH,XN
CA,XH,XN
CA,XH,XN
CA
CA
CA
CA,SC
CA
CA
CA,SC

DT2
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA,
CA,XH,XN
CA
CA,CT,SC
CA,CT
CA,CT

MT1
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

MT2
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

ACP Series continued


Watts
07S
10S
13S
14S
15S
17M
20S
23S
25S
23M
25M
31S
40S
40M

MT7
CA,CT,XH,XN
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

TT3
CT,XH,XN
CT,XH,XN
CA
CA
CA,CT
CA,CT
-

5T4
CA
CA
CA
CA

Product Guide

173

Floodlighting
B A L L A S T

M AT R I C E S

Series 75
Watts
10S
15S
17M
20S
23S
25S
23M
25M
31S
40S
40M

120
CA,CT,RH,RN
CA,CT,RH,RN
CA
CA
CA
CA,XH,XN
CA
CA
CA
CA,CT
CA,CT

208
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA
CA
CA,CT
CA

240
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA,RH,RN
CA
CA,XH,XN
CA
CA
CA
CA,CT
CA,CT

277
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA,
CA
CA
CA,CT
CA

TT3
XH,XN,CT
CA
CA
CA,CT
CA,CT
-

5T4
CA
CA
CA
CA

347
CT,XH,XN
CA
CA
CA,CT,SC
CA
-

480
CA,XH,XN
CA,XH,XN
CA
CA
CA
CA,SC
CA
CA
CA,SC

DT2
CA,CT,XH,XN
CA
CA
CA
CA,XH,XN
CA
CA,CT,SC
CA
CA,CT
CA,CT

MT1
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA,SC

Series 75 continued
Watts
10S
15S
17M
20S
23S
25S
23M
25M
31S
40S
40M

MT2
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA

MT7
CA,CT,XH,XN
CA,CT,XH,XN
CA
CA
CA
CA
CA
CA,SC
CA
CA

Series 77
Watts
40S
40M
75S
X1S
X1M

120
CA,CT,XN,XH,MR
CA,CT,SC
CA
CA,CT
CA,SC

208
CA,CT
CA,CT,SC
CA
CA,CT
CS,SC

220
RN,RH
CA
CA

240
RH,RN,CA,CT,MR
CA,CT,SC
CA
CA,CT
CA,SC

TT1
CA
CA
CA,SC

TT7
CA
CA
CA,SC

277
CA,CT
CA,SC
CA
CA,CT
CA,SC

480
CA,MR
CA,CT,
CA,CT
CA,SC

DT1
CA,CT,,XN,XH,MR
CA,CT
CA
CA,CT
CA,SC

DT2
CA,CT,,XN,XH,MR
CA,CT
CA
CA,CT
CA,SC

Series 77 continued
Watts
40S
40M
75S
X1S
X1M

MT7
CA,CT
CA,SC
CA
CA,SC

MT8
CA,CT
CA,SC
CA
CA,SC

TT3
CA
CA
CA
CA,SC

347
CA
CA
CA,SC

Energy Saver Series CES


Watts
03S
05S
05M
07S
07M
10S
10M
15S
15M
17M

174

120
RN,RH
RN,RH
XN,XH
RN,RH
XN,XH
RN,RH
XN,XH
RN,RH
XN,XH
CA

208
CA

Product Guide

240
CA

277
XN,XH
XN,XH
XN,XH
XN,XH
CA

DT2
CA

MT1
CA

MT2
CA

MT7
CA

For photometric information, visit our website,


www.americanelectriclighting.com

DT3
MR
CT
-

DT4
MR
CT
-

MT1
CA,CT
CA,SC
CA
CA,SC

MT2
CA,CT
CA,SC
CA
CA,SC

DARK TO LIGHT

ELECTRONIC PHOTOCONTROLS
DP 1704 ...................................................................176
DP Series .................................................................177
DE Series .................................................................178
DX Series .................................................................179
DUX Series ..............................................................180
D7790 Series............................................................181
DD Series.................................................................182
DPN Series ..............................................................183
DBE Series...............................................................184
Shorting and Open Caps .......................................185
Photocontrol Accessories ....................................186
Photocontrol Recommendation Chart ................186
ANSI Color Chart ....................................................186

American Electric Lighting

175

DP 1704 Utility Premium


Electronic Locking Type Photocontrol
O R D E R I N G

I N F O R M AT I O N

Features:

NEW

Special components provide superior reliability for large wattage fixtures or


other applications that overheat or damage ordinary photocontrols
Silicon photocell provides long-term drift-free light sensing at elevated
temperatures
Heat stabilized polymers are used in the base, enabling the control to
withstand the high temperatures found on 400 and 1,000 watt HID floodlights
ANSI standard 1.5 footcandle turn on
Fast delivery from stock
Eight-year warranty
Brown cover for identification
Multi-volt, 120/208/240/277 VAC
MOV surge protection, 320 Joule, 10,000 AMP

Applications:

Best of Everything control

Roadway and area lighting

PREFERRED SELECTION CATALOG NUMBERS

DP124-1.5-1704 J50

Ordering Information

Example: D P 1 2 4 - 1 . 5 - 1 7 0 4 J 5 0

Voltage
DP124

Premium

Turn-on Level (ftc)1

120/208/240/277 Volts
(105305)

1.5

ANSI Standard

1704

Job Packs
J50 50 Units

DIMENSIONS

Notes:
1

176

Product Guide

For more information, visit our website,


www.americanelectriclighting.com

Other options available,


please contact your local
American Electric Lighting
representative

DP Series Silicon
Electronic Locking Type Photocontrol
O R D E R I N G

I N F O R M AT I O N

Features:
Silicon light sensor
Complies with ANSI C136.10-1996
MOV surge protection
Long life
Energy efficient
Six-year warranty
Available in job packs of J12 or J50 only
Heat stabilized polymers are used in the base, enabling the control to
withstand the high temperatures found on 400 and 1,000 watt HID floodlights
and other fixtures
Inverse ratio (DPR) and fail off (DPF) options available

Applications:

Inverse Ratio Controls are ideal for areas where it is important to turn on lights
early but energy costs are a concern. Turn-off level is lower than turn-on
levels. Model listed, DPR124-2.6-TJBK J50, is most commonly ordered.
Various other models available. Contact your local American Electric Lighting
representative for details and specifications.

Roadway and area lighting


Floodlights
Areas with very high temperatures
(DP Series High Temp/Floodlight)

Fail Off Controls are occasionally used for leased lighting. Model
DPF124-1.5-TJ J50 is most commonly ordered. Various other models available.
Contact your local American Electric Lighting representative for details and
specifications.

PREFERRED SELECTION CATALOG NUMBERS

DP124-1.5-TJ J50
DP120-1.5-TJ J50
DP124-1.5-TJBK J50

Ordering Information
Voltage
DP120
DP124

120 Volts (105130)


120/240/277 Volts
(105305)
DP240 240 Volts (185305)
DP347 347 Volts (300400)
DP480 480 Volts (420530)
DPR124 Multi-volt Inverse
ratio
DPF124 Multi-volt Fail Off

Example: D P 1 2 0 - 1 . 5 - T J B K J 5 0
Turn-on Level (ftc)1
1.0
1.5
2.6
8.0
35

Time Delay (seconds)1

T
Energy Saver
ANSI Standard
IES Recommendation
Automile (High
Ambient Light)
FAA

2-5 Second Turn-off


Delay

Cover Color 1

Surge Protector
J

320 J/10,000 Amp


MOV

(blank)
BK
BR
P

ANSI Standard Color*


Black
Brown
Upward Facing

* See chart page 186

Job Packs

DIMENSIONS

J12 12 Units
J50 50 Unit

Notes:
1

Other options available, please contact


your local American Electric Lighting
representative

Upward Facing

Product Guide

177

DE Series Filtered Silicon


Electronic Locking Type Photocontrol
O R D E R I N G

I N F O R M AT I O N

Features:
Filtered silicon light sensor
Human eye spectral response
Complies with ANSI C136.10-1996
MOV surge protection
Long life
Energy efficient
Six-year warranty
Available in job packs of J12 and J50 only
Silicon sensor with infrared blocking filter
Polypropylene cover, neoprene gasket, brass legs, acrylic window
Base rated for 120C

Applications:

Power consumption: 0.5 watts

Roadway and area lighting


Areas with variable sky conditions
Areas with high temperatures

Load rating: 1000 watts, 1800 VA ballast


Sealed relay rated for 5000 operations at full load
Turn OFF light level is 1.5 times turn ON.
3.4 ounces each

PREFERRED SELECTION CATALOG NUMBERS

-40 to +70C ambient, Up to 90 interface per ANSI

DE120-1.5-TJ J50
DE124-1.5-TJBK J50
DE124-1.5-TJGY J50

Dielectric strength: 5000 V per ANSI

Ordering Information
Voltage
DE120
DE124
DE347
DE480

120 Volts (105130)


120/240/277 Volts
(105305)
347 Volts (300400)
480 Volts (420530)

Example: D E 1 2 0 - 1 . 5 - T J J 5 0
Time Delay (seconds)1

Turn-on Level (ftc)1


1.0
1.5
2.6
8.0
35

Energy Saver
ANSI Standard
IES Recommendation
Automile (High
Ambient Light)
FAA

2-5 Second Turn-off


Delay (standard)
Surge Protector

320 J/10,000 Amp


MOV

Cover Color 1
(blank)
BK
P

ANSI Standard
Color*
Black
Upward Facing

Job Packs
J12 12 Units
J50 50 Units

* See chart page 186

DIMENSIONS

Notes:
1

Upward Facing

178

Product Guide

For more information, visit our website,


www.americanelectriclighting.com

Other options available,


please contact your local
American Electric Lighting
representative

DX Series
Electronic Locking Type Photocontrol
O R D E R I N G

I N F O R M AT I O N

Features:
Silicon light sensor
Complies with ANSI C136.10-1996
MOV surge protection
Long life
Energy efficient
Economical
Six-year warranty
Available in job packs of J12 or J50 only
Standard 160 joule, 6500 amp MOV rated for multiple surges
Polypropylene cover, Neoprene gasket, brass legs, acrylic window base rated
for 120C

Applications:

Power consumption: 0.5 watts

Roadway and area lighting


Security lighting
Municipal lighting

Load rating: 1000 watts, 1800 VA ballast


Sealed relay rated for 5000 operations at full load
3.4 ounces each

PREFERRED SELECTION CATALOG NUMBERS

-40 to +70C ambient, Up to 90 interface per ANSI


Dielectric strength: 5000 V per ANSI

DX124-12A J50
DX124-12A J12

Example: D X 1 2 4 - 1 2 A J 5 0

Ordering Information
Voltage
DX120
DX124
DX347
DX480

Sensor

Turn-on Level (ftc)

120 Volts (105130)


120/240/277 Volts
(105305)
347 Volts (300400)
480 Volts (420530)

1.23 ftc Turn-on


(standard)

Silicon Sensor,Time
Delay (2-5 seconds)

Cover Color
A

ANSI Standard*

Job Packs
J12 12 Units
J50 50 Units

* See chart page 186

DIMENSIONS

Product Guide

179

DUX Series
Locking Type Photocontrol UL Listed
O R D E R I N G

I N F O R M AT I O N

Features:
Silicon light sensor
Complies with ANSI C136.10-1996
MOV surge protection
Long life
Energy efficient
Economical
Six-year warranty
Available in job packs of J12 or J50 only
Standard 160 joule, 6500 amp MOV rated for multiple surges
Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated
for 120C

Applications:
Area lighting
Security lighting
Yard lighting

Power consumption: 0.5 watts


Load rating: 1000 watts, 1800 VA ballast
Sealed relay rated for 5000 operations at full load
3.4 ounces each

PREFERRED SELECTION CATALOG NUMBERS

-40 to +70C ambient, up to 90 interface per ANSI

DUX124-12A J50
DUX124-12A J12

Dielectric strength: 5000 V per ANSI


UL listed is standard

Ordering Information

Example: D U X 1 2 4 - 1 2 A J 5 0

Voltage
DUX120 120 Volts (105130)
DUX124 120/240/277 Volts
(105305)
DUX480 480 Volts (420530)

1.23 ftc Turn-on


(standard)

Silicon Sensor, Time


Delay (2-5 seconds)

Upward Facing

Product Guide

A
P

ANSI Standard*
Upward Facing

* See chart page 186

DIMENSIONS

180

Cover Color

Sensor

Turn-on Level (ftc)

For more information, visit our website,


www.americanelectriclighting.com

Job Packs
J12 12 Units
J50 50 Units

D7790 Series
Electronic Locking Type Photocontrol
O R D E R I N G

I N F O R M AT I O N

Features:
Silicon light sensor
Complies with ANSI C136.10-1996
Two-year warranty
Standard 190 joule, 4500 amp MOV
Polypropylene cover, Neoprene gasket, brass legs, acrylic window
Base rated for 120C
Power consumption: 0.5 watts
At 120 VAC Load rating: 1000 watts, 1800 VA ballast
Sealed relay rated for 5000 operations at full load
Instant turn on, 2-5 second turn off

Applications:

Turn on is 1.5 + 0.5 ftc, turn off is 1.5 times turn on

Replacement for many industry standard locking type


photoocontrols

3.4 ounces each


Available in job packs of J12 or J50 only
-40 to +70C ambient, Up to 90 interface per ANSI

PREFERRED SELECTION CATALOG NUMBERS

Dielectric strength: 5000 V per ANSI


D7790 is a replacement for many industry standard type locking photocontrols

D7790 J50

Sealed in individual poly bags

Ordering Information

Example: D 7 7 9 0 J 5 0

Job Pack

Voltage
D7790 120/208/240/277 VAC

J12
J50

12 Units
50 Units

DIMENSIONS

Product Guide

181

DD Series Diagnostics
Electronic Locking Type Photocontrol
O R D E R I N G

I N F O R M AT I O N

Features:
Regular dusk to dawn operation
Diagnostic feature detects and disables cycling HPS lamps and
lamps that fail to start
Extends starting aids life
Flashing or steady LED alerts line crew of problem
Filtered silicon light sensor
2-5 second off delay
MOV surge protection
Complies with ANSI C136.10-1996; not for use on incandescent fixtures
Six-year warranty
Available in job packs of J12 or J50 only

Applications:

Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated
for 120C

Roadway and area lighting


High profile installations
Anywhere cycling lamps are a problem
Anywhere starting aid life is a problem

Power consumption: 1.0 watts


Load rating: 70-400 watt HPS
Sealed relay rated for 5000 operations at full load
3.8 ounces each
-40 to +70C ambient, Up to 90 interface per ANSI
Dielectric strength: 5000 V per ANSI

Ordering Information
Voltage
DD124

120/208/240/277
Volts (105-305)

Example: D D 1 2 4 - 1 . 5 - T J A J 5 0

1.5

ANSI Standard

Cycle Detection1

Time Delay (seconds)

Turn-on Level (ftc)


T

2-5 Second Turn-off


Delay (standard)

After Five Lamp Cycles,


Control Turns Lamp Off. Next
Dusk, Control Turns Lamp On
and Cycle Detection
Circuit Restarts

Job Packs
J12
J50

12 Units
50 Units

Surge Protector
J

DIMENSIONS

320J/10,000 Amp
MOV

Notes:
1
2

182

Product Guide

For more information, visit our website,


www.americanelectriclighting.com

Available with black cover only


Cycle Detection Program is set at
factory; program cannot be altered
in field

DPN Series Part Night


Electronic Locking Type Photocontrol
O R D E R I N G

I N F O R M AT I O N

Features:
Control turns on at dusk and off halfway through the night. Automatically
self-adjusts to seasonal time changes, reducing maintenance
Reduces light pollution and light trespass concerns
Filtered silicon photocell provides long-term, drift-free light sensing.
The infrared blocking polymer filter gives human eye response.
A 2-5 second off-time delay is provided to avoid turn-off from extraneous light.
Complies with ANSI C136.10-1996
Six-year warranty
Energy Savings
Available in job packs of J12 or J50 only
Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated
for 120C

Applications:

Power consumption: 0.8 watts

Parking lots
Area lights
Park lights
Media lighting
Ball fields and courts
Pedestrian lighting

Load rating: 1000 watts, 1800 VA ballast


Sealed relay rated for 5000 operations at full load
Turn OFF is at middle of the night.
3.6 ounces each
-40 to +70C ambient, Up to 90 interface per ANSI
Dielectric strength: 5000 V per ANSI

Ordering Information

Example: D P N 1 2 4 - 2 . 6 - T J G N J 5 0

DPN124

Time Delay (seconds)

Turn-on Level (ftc)1

Voltage
120/240/277 Volts
(105-305)

1.5
2.6

ANSI Standard
Standard

Cover Color
GN

2-5 Second Turn-off


Delay (standard)

Job Packs

Green (only)

J12 12 Units
J50 50 Units

Surge Protector
J

320 J/10,000 Amp


MOV

DIMENSIONS

Notes:
1

Other options available, please contact


your local American Electric Lighting
representative

Product Guide

183

DBE Series Button


Electronic Wire-In Photocontrol
O R D E R I N G

I N F O R M AT I O N

Features:
Electronic wire-in button photocontrol
Instant turn-on, standard 5-10 second turn-off time delay
Filtered Silicon light sensor
UL listed models available
Filtered silicon light sensor
Voltages 120347
Complies with ANSI C136.24
Long life
Low maintenance
Six-year warranty

Applications:

Available in job packs of J12 only

Park lighting
Security lighting
Post lanterns
Decorative and area lighting

190 Joule MOV surge protection


12, 200C, #16 wire leads

PREFERRED SELECTION CATALOG NUMBERS

DBE124-1.5-T J12
DBE120-1.5-T J12
Example: D B E 1 2 0 1 . 5 - T J 1 2

Ordering Information

Voltage
DBE120
DBE240
DBE347
DBE124

Time Delay (seconds)

Turn-on Level (ftc)

120 Volts (105130)


208/240/277 Volts (200305)
347 Volts (300400)
120/240/277 Volts (105305)

1.5

ANSI Standard

5-10 Second Turn-off


Delay (standard)

DIMENSIONS
3/8 (18) Straight pipe thread

184

Product Guide

For more information, visit our website,


www.americanelectriclighting.com

Certification
(blank)
U

No Listing
CSA and
UL Listed

Job Pack
J12

12 Units

Shorting and Open Caps


Locking Type
O R D E R I N G

I N F O R M AT I O N

SHORTING AND OPEN CAPS


For luminaires where lights are to be on continuously (shorting cap)
or left off (open cap). Exceeds ANSI C136.10-1996.
Description

Catalog Number

Shorting cap. Black Cover

D-SHORT-SBK

Shorting cap 320J. MOV surge protection. Black cover.

D-SHORT-VBK

Open cap. Red cover.

D-OPEN-SRD

PREFERRED SELECTION CATALOG NUMBERS

D-SHORT-SBK J12
D-SHORT-VBK J12
D-OPEN-SRD J50
DIMENSIONS

Product Guide

185

Photocontrol Accessories
OA RC DC E RS IS NO GR I IENS F O R M A T I O N
Catalog
Number

Description

PHOTOCONTROL RECEPTACLES
PREFERRED SELECTION
Mounting adapter for connecting photocontrol to net. For pole,
CATALOG NUMBER
wall and frame mounting. 14 x 14 gage wire. Line = black,
Load = red, Neutral = white. Each receptacle meets NEMA
DUR-103 J6
and ANSI standards.
With bracket and rotating cup with locknut

DUR-103

PHOTOCONTROL TESTCAP
Lightweight black vinyl cap tests the working operation
of photocontrols during daylight hours. Completely
eliminates direct and reflected light, enabling quick and
easy testing. Not designed for use with hot sticks.
Affordably priced.

D-TESTCAP

ANSI Color Chart

Photocontrol Recommendation Chart


DTL
SERIES

Type

Voltages
Available

Light
Sensor

Surge
Protection

Application

Typical
Electronic

DP

Locking

120 thru 480

Silicon

MOV, 320 Joule

Roadway

Yes

DE

Locking

120 thru 480

MOV, 320 Joule

Roadway

Yes

DX

Locking

120 thru 480

Filtered
Silicon
Silicon

MOV, 320 Joule

C&I + Roadway

Yes

DUX

120 thru 480

Silicon

MOV, 320 Joule

Yes

120-277

Silicon

MOV, 160 Joule

Where UL
is needed
Off-Roadway

120-277

Silicon

MOV, 160 Joule

Roadway

Yes

DBE

Locking,
UL listed
Locking,
Part Night
Locking,
Diagnostic
Button

120 and 208-277

MOV, 190 Joule

Utility post top

Yes

D7790

Locking

120 thru 347

Filtered
Silicon
Silicon

MOV, 190 Joule Roadway or export

Yes

DPF

Locking,
Fail OFF
Locking,
Inverse Ratio
Locking,
Reverse

120-277

Silicon

MOV, 320 Joule

Off-Roadway

Yes

120-277

Silicon

MOV, 320 Joule

Roadway

Yes

120-277

Silicon

MOV, 320 Joule

OFF night, ON day

Yes

DD

DPR
DPO

186

Product Guide

D-TESTCAP J50

PHOTOCONTROL DEMO BOX


Portable 120 volt test box.
Dimensions: 51/2 x 3 x 21/2 inches.

D-DEMO BOX

DPN

PREFERRED SELECTION
CATALOG NUMBER

For more information, visit our website,


www.americanelectriclighting.com

Yes

ANSI Color Codes


120V
240V
Multivolt
350V
480V

Gray
Maroon
Dark Blue
Green
Yellow

POLES
Illustrated Samples ................................................188

RSA ...........................................................................192

Wind Map ................................................................189

RTA............................................................................193

Florida Wind Rating................................................190

RSAH ........................................................................194

General Information...............................................191

SSA ...........................................................................195
SSAH ........................................................................196
RSS ...........................................................................197
RTS............................................................................198
SSS ...........................................................................199
STS............................................................................200
STSH.........................................................................201
Pole Options ............................................................202
Aluminum Mounting Brackets .............................203
Steel Mounting Brackets ......................................204
RTF ............................................................................205
RTFDB.......................................................................206
SSF............................................................................207
STC............................................................................208
SPRTC.......................................................................209
SPRTS.......................................................................213
RTAU.........................................................................216
RTSU.........................................................................220
AMAW / SMAW / Arms for Wood Poles ............222
AMAC / SMAC / Arms for Concrete Poles .........224
SMAWL / Arms for Wall Mount ...........................226
Traditional Wood Pole Arms.................................228
Traditional Concrete Pole Arms...........................229

American Electric Lighting

187

I L L U S T R AT E D

S A M P L E S

There are several different pole types available throughout this section. Below are a few examples. Please contact your local American Electric
Lighting representative for more information.

Round Straight Aluminum

Round Straight Steel

Round Tapered Aluminum

Round Tapered Fiberglass

4
Bolt Projection
18

Square Straight Steel

Square Straight Aluminum

Square Tapered Steel

188

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

Square Tapered Steel Hinge

Contact AEL for specific data.

W I N D
M A P

Product Guide

189

F L O R I D A

P O L E

Steel

W I N D

R AT I N G

C H A R T

SIDE-MOUNTED LOAD
max. wt.
Max WT/EPA Max WT/EPA
Max WT/EPA
that will be used 130mph Zone 140mph Zone
150mph Zone
100
14.2 / 100
12.1 / 100
10.3 / 100
200
10.9 / 200
9.3 / 200
7.9 / 200
200
12.2 / 200
10.4 / 200
8.9 / 200
225
10.0 / 225
8.2 / 225
6.9 / 225
225
19.3 / 225
16.3 / 225
13.9 / 225
225
9.6 / 225
7.6 / 225
5.9 / 225
225
13.9 / 225
11.4 / 225
9.5 / 225

TENON-MOUNTED LOAD
Max WT/EPA
Max WT/EPA Max WT/EPA
130mph Zone
140mph Zone 150mph Zone
13.1 / 100
11.2 / 100
9.5 / 100
10.3 / 200
8.7 / 200
7.4 / 200
13.3 / 200
11.3 / 200
9.7 / 200
9.5 / 225
7.9 / 225
6.6 / 225
18.3 / 225
15.5 / 225
13.2 / 225
9.2 / 225
7.3 / 225
5.7 / 225
13.3 / 225
11.0 / 225
9.2 / 225

RTS

20
25
25
30
30
35
39

6-5B
7-0B
7-0F
8-0B
8-0F
9-5B
9-0F

SSS

20
25
30

5G
5G
6G

100
100
100

10.7 / 100
5.5 / 100
4.7 / 100

8.5 / 100
3.8 / 100
2.7 / 100

6.7 / 100
2.4 / 100
1.0 / 100

10.0 / 100
5.3 / 100
4.6 / 100

7.9 / 100
3.6 / 100
2.6 / 100

6.2 / 100
2.4 / 100
1.1 / 100

SSA

20
25

6G
6J

100
100

5.8
3.5

0
0

2.4
0

0
0

0
0

0
0

RTA

20
25
30
30
35

7E
8G
8G
10G
10G

100
200
200
225
225

7.5
8.8
5.6
11.4
8

6.4
7.4
4.6
9.4
6.4

5.3
6.2
3.7
7.7
5

7.2
8.5
5.5
11.2
7.9

5.8
6.9
4.3
8.9
6.1

5.1
6
3.7
7.6
4.9

Aluminum

190

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

Poles
General Information
Poles are available only in US

O R D E R I N G

I N F O R M AT I O N

Example: S S A 1 6 4 G D M 1 9 D D B A E L

Shaft type
RTA
RSA
RSAH
SSA
SSAH
RTS
STS
STSH
RSS
SSS
SSF
RTF
RTFDB
SPRTC
STC
SPRTS

Nominal shaft base


size/wall
thickness (in.)

Round Tapered Aluminum


Round Straight Aluminum
3 B
0.120
Round Straight Aluminum Hinged
4 C
0.125
Square Straight Aluminum
5 E
0.156
Square Straight Aluminum Hinged
6 G
0.188
Round Tapered Steel
7 J
0.250
Square Tapered Steel
8 K
0.312
Square Tapered Steel Hinged
9 L
0.219
Round Straight Steel
10 P
0.375
Square Straight Steel
Square Straight Fiberglass
Nominal mounting height
Round Tapered Fiberglass
Round Tapered Fiberglass
850 feet Sportslighting Poles
Direct Burial
up to 115 Feet
Round Tapered Concrete
See website for specific
Sportslighting
information.
Square Tapered Concrete
Round Tapered Steel
Sportslighting

NOTES:
1 Other colors available, please contact your local
American Electric Lighting representative.
2 Aluminum poles only.

Options

Fixture Mounting Method


Only Open-top Pole
Accepts KKS
(4" square) and KKR
(4-1/2" round)
Luminaires
Tenon Mounting
T20 2-3/8" O.D. (2" NPS)
T25 2-7/8" O.D. (2-1/2" NPS)
T30 3-1/2" O.D. (3" NPS)
T35 4" O.D. (3-1/2" NPS)
Drill Mounting
DM19 1 at 90
DM28 2 at 180
DM29 2 at 90
DM39 3 at 90
DM49 4 at 90
DM32 3 at 120 (Round Poles)

See Page Architectural Colors1


Polyester Powder
202
Standard Colors
DDB Dark bronze
DWH White
DBL Black
BA Brushed
Aluminum2

PT

Ordering Information:

Finish

Drill Mounting
(blank)
A
B
C
D
E

Class 1 Architectural
Anodize (Aluminum only)
ABL Black
ADB Dark bronze
ANA Natural

ASA & AVL


Sq Pole 53
Sq Pole 153
Sq Pole LS, LM, LL
Rd Pole 53 & 153
AVL w/A4 Option

Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then
add AEL after the last option

All luminaire/pole assemblies require proper


evaluation to ensure that the structural integrity of the
assembly is not compromised when applied in
specific wind conditions. Therefore, the basis for pole
selection in this catalog is total weight and effective
projected area, EPA (ft2), shown on the individual pole
catalog pages. Determination of maximum EPA (ft2)
and weight loading must include all luminaires,
bracketry, signs, decorations, overhead wires or
other equipment that will be mounted to the subject
pole. Luminaire EPA (ft2) and weight data are found
on their respective product pages.
The total effective projected area of the luminaires
and brackets shall not exceed the EPA (ft2) listed for
the pole selected at a given wind velocity. Poles that
are to be located in areas of known abnormal
conditions will require special consideration. The
map on page 189 gives the wind velocities to be used
in determining luminaire pole compatibility.
Note: If during the pole warranty period of one year, the
product proves defective in material or workmanship, the
company shall correct, at its option, by repairing or replacing
at no charge to the purchaser, if the purchaser promptly
notifies the company. This warranty specifically excludes
fatigue failure or similar phenomena resulting from induced
vibration harmonic oscillation or resonance associated with
the movement of air currents around the product.

Pole Selection Procedure


Step 1. Select the luminaire and decide how many will be mounted per pole. Determine the Effective Projected
Area, EPA (ft2), which is given on the dimensional information table.
Step 2. Determine the appropriate mounting method for the luminaire. Options include arm, bracket or tenon
mounting.
Step 3. Add together the EPA's (ft2) of the luminaire and arm/bracket. Multiply by number of fixtures to be
mounted on one pole.
Step 4. Consult the Wind Map on page 189 to determine the basic wind velocity for your area.
Step 5. Select the material (steel or aluminum) and shape (square or round) of the pole. Refer to the Technical
Information chart on the appropriate pole page.
A. Find the desired nominal mounting height in the second column.
B. Verify that the fixture weight does not exceed the maximum weight listed for the desired pole.
C. Compare your total EPA (ft2) loading with the maximum EPA (ft2) value found in the wind speed column for
your area. Check that the equipment you are using will not exceed this value.
D. If both the weight and EPA (ft2) values do not exceed the values for which the pole is rated, you have selected
the correct pole. If, however, either one of those numbers exceeds the maximum rated values, compare the EPA
(ft2) and fixture weight loads to the next larger pole of the same mounting height.

CAUTION: This pole selection process is a guideline only. American Electric Lighting assumes no responsibility
for selection and recommends consultation with qualified individuals for verification of luminaire/pole assembly
selection.

Pole Data1

4 Bolt Base

3 Bolt Base

Shaft
Base
size

Bolt
circle
A

Bolt
projection
B

Base
square
C

Warehouse
Anchor Bolt
description

Template
number

4"
4-1/2"
5"
6"
3"
4"
5

6-1/2"8-1/4"
78-1/2"
7-1/2"9-1/2"
8-3/4"10-1/4"
5-1/2"7"
6-5/167-3/8"
7-3/8"8-1/2"

3-1/4"
3-1/4"
3-1/4"
3-1/2"
4-1/8"
4-1/4"
4-1/2"

8-3/4"
8-1/2"
9-1/4"
10-1/4"
10-1/2"
11-1/2"
14-1/2"

AB18-0
AB18-0
AB18-0
AB30-0
AB36-0
AB36-0
N/A

PJ50057
PJ50040
PJ50058
PJ50059
PJ50125
PJ50126
PJ50127

1 Pole Data for RSA, page 192

Product Guide

191

RSA
Anchor Base Poles
Round Straight Aluminum

P R O D U C T

O V E R V I E W

Intended Use
For 8 to 30 mounting height.

Grounding Ground lug located immediately inside handhole is


tapped for ground bolt (not supplied by others).

Features:
Shaft One-piece extruded 6063-T6 aluminum alloy with T6 temper.
Circumferential satin-brushed finish. 4 1/2" round straight tube is
uniform in cross-section down length of shaft.

Handhole A nominal 2 x 4 or 3 x 5 reinforced handhole is


centered 18 above the base. Cover and attachment hardware
furnished.
Hardware Stainless steel.

Anchor Base Cast from A356 aluminum alloy and heat treated to T6
temper. Base slipfits shaft, and they are joined together by continuous
circumferential welds at both top and bottom of anchor base to
provide maximum strength at area of critical stress.

Top Cap Cast-aluminum cap is provided for drill-mount poles.

Anchor Bolts Top 12" is galvanized per ASTM A-153. Made of carbon
steel bar with a minimum-yield strength of 55,000 psi.

Bolt Covers A356 nut covers included with anchor base unless
otherwise specified.

Finish Standard finish is brushed aluminum. Optional polyester


powder paint and anodized finishes available.

Ordering Information: See page 191


(Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust

INSTALLATION NOTES:
Installation requires grout to be packed under base
to ensure full contact with foundation. Factorysupplied templates must be used when setting
anchor bolts. American Electric Lighting will not
accept claim for incorrect anchorage placement due
to failure to use American Electric Lighting factory
templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately upon delivery to
prevent finish damage.

Catalog
Number
4 Bolt Base
RSA 8 4C
RSA 10 4C
RSA 12 4C
RSA 14 4C
RSA 14 4-5C
RSA 14 5C
RSA 16 4C
RSA 16 4-5C
RSA 16 4-5G
RSA 16 5C
RSA 16 5E
RSA 18 4-5G
RSA 18 5C
RSA 18 5E
RSA 18 5G
RSA 20 4-5G
RSA 20 5C
RSA 20 5E
RSA 20 5G
RSA 20 6E
RSA 25 4-5G
RSA 25 6E
RSA 25 6G
RSA 30 6G
3 Bolt Base
3RSA 8 3C
3RSA 10 3C
3RSA 10 4C
3RSA 12 3C
3RSA 12 4C
3RSA 12 5C
3RSA 14 3C
3RSA 14 4C
3RSA 14 5C
3RSA 16 4C
3RSA 16 5E
3RSA 18 5C
3RSA 20 5C
3RSA 20 5E

Nom.
Pole
Wall
mount. Shaft Size Thick.
ht. (ft.) (in. dia. x ft.) (in.)

80
mph

90
mph

100
mph

Max.
wt.

Bolt
Circle
(in.)

8
10
12
14
14
14
16
16
16
16
16
18
18
18
18
20
20
20
20
20
25
25
25
30

4.0 x 8.0
4.0 x 10.0
4.0 x 12.0
4.0 x 14.0
4.5 x 14.0
5.0 x 14.0
4.0 x 16.0
4.5 x 16.0
4.5 x 16.0
5.0 x 16.0
5.0 x 16.0
4.5 x 18.0
5.0 x 18.0
5.0 x 18.0
5.0 x 18.0
4.5 x 20.0
5.0 x 20.0
5.0 x 20.0
5.0 x 20.0
6.0 x 20.0
4.5 x 25.0
6.0 x 25.0
6.0 x 25.0
6.0 x 30.0

0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.188
0.125
0.156
0.188
0.125
0.156
0.188
0.188
0.125
0.156
0.188
0.156
0.188
0.156
0.188
0.188

11.2
8.2
6.0
4.1
5.8
7.8
2.8
4.2
7.5
5.9
8.0
5.7
4.3
6.1
8.0
4.3
3.0
4.7
6.4
9.3
1.3
5.2
7.1
3.5

8.6
6.1
4.3
2.8
4.2
6.0
1.6
2.8
5.5
4.4
6.1
4.0
3.1
4.6
6.8
2.9
2.1
3.4
4.8
7.1

3.8
5.3
2.4

6.8
4.7
3.2
1.9
3.3
4.7
1.0
2.1
4.3
3.4
4.8
3.1
2.4
3.5
4.7
2.1
1.5
2.6
3.6
5.5

2.8
4.0
1.6

125
100
110
75
60
100
150
50
155
175
190
123
150
175
225
95
150
150
150
175
100
150
150
200

6-1/2-8-1/4
6-1/2-8-1/4
6-1/2-8-1/4
6-1/2-8-1/4
7-1/8-8-3/8
7-1/2-9-1/2
6-1/2-8-1/2
7-1/8-8-3/8
7-1/8-8-3/8
7-1/2-9-1/2
7-1/2-9-1/2
7-1/8-8-3/8
7-1/2-9-1/2
7-1/2-9-1/2
7-1/2-9-1/2
7-1/8-8-3/8
7-1/2-9-1/2
7-1/2-9-1/2
7-1/2-9-1/2
8-3/4-10-1/4
7-1/8-8-3/8
8-3/4-10-1/4
8-3/4-10-1/4
8-3/4-10-1/4

3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3

22
26
30
35
42
39
38
46
62
46
53
68
48
58
68
74
54
68
82
95
89
108
128
146

8
10
10
12
12
12
14
14
14
16
16
18
20
20

3.0 x 8.0
3.0 x 10.0
4.0 x 10.0
3.0 x 12.0
4.0 x 12.0
5.0 x 12.0
3.0 x 14.0
4.0 x 14.0
5.0 x 14.0
4.0 x 16.0
5.0 x 16.0
5.0 x 18.0
5.0 x 20.0
5.0 x 20.0

0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.156
0.125
0.125
0.156

5.8
4.0
8.2
2.7
5.8
10.3
1.7
4.1
7.9
2.8
8.0
4.3
2.9
4.6

4.3
2.9
6.1
1.8
4.2
8
1.0
2.8
6.0
1.6
6.1
3.1
2.0
3.3

3.3
2.3
4.7
1.2
3.1
6.3
0
1.9
4.7
1.0
4.8
2.4
1.4
2.5

75
75
75
75
150
150
75
150
150
150
150
150
150
150

5-1/2-7
5-1/2-7
6-5/16-7-3/8
5-1/2-7
6-5/16-7-3/8
7-3/8-8-1/2
5-1/2-7
6-5/16-7-3/8
7-3/8-8-1/2
6-5/16-7-3/8
7-3/8-8-1/2
7-3/8-8-1/2
7-3/8-8-1/2
7-3/8-8-1/2

3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3

22
26
26
30
30
36
35
35
39
38
53
48
54
68

NOTES:
For Pole Data Chart, see page 191

192

Product Guide

Bolt
Approx.
Size
ship wt.
(in. x in. x in.) (lbs.)

For more information please visit our website:


www.americanelectriclighting.com

RTA
Anchor Based Poles
Round Tapered Aluminum

P R O D U C T

O V E R V I E W

Intended Use
For 20 to 39 mounting height.

Grounding A ground lug located immediately inside the handhole is


tapped for 3/8-16 UNC ground bolt (by others).

Features

Handhole A nominal 3"x5" or 4"x6" reinforced flush covered


handhole is centered 18" above the base.

Shaft The shaft is spun tapered from seamless 6063 alloy aluminum
tubing and is heat-treated to produce a T6 temper. The shaft is cone
tapered to the butt diameter.

Hardware Stainless steel.

Anchor Base Cast from A356 alloy aluminum, the anchor base is
heat-treated to a T6 condition. The anchor base telescopes the pole
shaft and is circumferentially welded top and bottom.

Top Cap Cast-aluminum cap is provided for drill mount poles.

Anchor Bolts Top 12" galvanized per ASTM A-153. Made of steel rod
having a minimum yield strength of 55,000 PSI.

Bolt Covers A356 nut covers shall be included with each anchor
base unless otherwise specified.

Finish Standard finish is brushed aluminum. Optional polyester


powder paint and anodized finishes available.

Ordering Information: See page 191


(Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
4 Bolt Base
RTA 20 5C
RTA 20 5G
RTA 20 6G
RTA 20 7E
RTA 25 6E
RTA 25 7E
RTA 25 8E
RTA 25 8G
RTA 30 7E
RTA 30 8E
RTA 30 8G
RTA 30 10G
RTA 35 8E
RTA 35 8G
RTA 35 8J
RTA 35 10G
RTA 39 8G
RTA 39 8J
RTA 39 10G
RTA 39 10J
3 Bolt Base
3RTA 8 4C
3RTA 10 4C
3RTA 12 4C
3RTA 14 4C
3RTA 16 4C
3RTA 16 5C
3RTA 18 5C
3RTA 18 5E
3RTA 20 5C
3RTA 20 5E

Nom.
Pole
Wall
mount Shaft Size Thickness 80
ht. (ft.) (in. x in. x ft.)
(in.)
mph

20
20
20
20
25
25
25
25
30
30
30
30
35
35
35
35
39
39
39
39

5 x 3 x 198
5 x 3 x 198
6 x 4 x 198
7 x 4 x 198
6 x 4 x 24 8
7 x 4 x 248
8 x 4.5 x 24 8
8 x 4.5 x 24 8
7 x 4 x 298
8 x 4.5 x 298
8 x 4.5 x 298
10 x 6 x 298
8 x 4.5 x 348
8 x 4.5 x 348
8 x 4.5 x 348
10 x 6 x 348
8 x 4.5 x 388
8 x 4.5 x 388
10 x 6 x 388
10 x 6 x 388

8
10
12
14
16
16
18
18
20
20

4.0 x 8.0
4.0 x 10.0
4.0 x 12.0
4.0 x 14.0
4.0 x 16.0
5.0 x 16.0
5.0 x 18.0
5.0 x 18.0
5.0 x 20.0
5.0 x 20.0

0.125
0.188
0.188
0.156
0.156
0.156
0.156
0.188
0.156
0.156
0.188
0.188
0.156
0.188
0.250
0.188
0.188
0.250
0.188
0.250
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.156
0.125
0.156

Approx
Bolt Circle
Bolt Size
ship wt.
(in.)
(in. x in. x in.) (lbs.)

90
mph

100
mph

Max.
wt.

3.9
7.4
12.2
15.0
5.3
9.5
14.2
18.0
5.5
9.4
12.4
23.8
5.8
8.3
12.9
17.9
5.6
9.7
14.2
20.4

2.5
5.2
9.2
11.4
3.6
7.0
10.9
13.8
3.8
7.0
9.4
18.3
4.1
6.0
9.7
13.6
3.9
7.1
10.5
15.5

1.6
3.8
7.2
9.0
2.6
5.4
8.5
10.9
2.7
5.3
7.3
14.3
2.9
4.5
7.5
10.4
2.7
5.4
7.8
11.9

100
100
214
256
114
162
220
261
111
151
179
377
119
141
183
295
122
158
253
300

7-1/2-9-1/2
7-1/2-9-1/2
910
9-7/8-11-1/4
910
9-7/8-11-1/4
1112
1112
9-7/8-11-1/4
1112
1112
14-1/4-16-1/4
1112
1112
1112
14-1/4-16-1/4
1112
1112
14-1/4-16-1/4
14-1/2-16

12.1
8.8
6.6
4.9
3.5
6.9
5.0
7.0
3.8
5.5

9.3
6.7
4.8
3.4
2.3
5.0
3.5
5.0
2.5
3.8

7.3
5.2
3.6
2.4
1.5
3.8
2.5
3.7
1.6
2.6

75
75
75
75
75
75
150
150
150
150

6-1/27-1/4
6-1/27-1/4
6-1/27-1/4
6-1/27-1/4
6-1/27-1/4
7-1/2-8-1/2
7-1/2-8-1/2
7-1/2-8-1/2
7-1/2-8-1/2
7-1/2-8-1/2

3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
1 x 36 x 4
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 40 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 40 x 4
1 x 36 x 4
1 x 36 x 4
1 x 40 x 4
1-1/4 x 48 x 5

62
72
107
103
106
120
130
153
135
150
175
235
185
220
251
268
250
280
295
373

3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3

n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
62
70

INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately upon delivery to
prevent finish damage.
NOTES:
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D.
(2" NPS)
Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures
at 180
Options: See page 202
Brackets: See page 203-204

18

Pole Data

4 Bolt Base

3 Bolt Base

Shaft
Base
size

Bolt
circle
A

Bolt
projection
B

Base
square
C

Anchor
Bolt
description

Warehouse
Anchor Bolt
description

Template
number

5"
6"
7"
8"
10"G
10"J
4"
5"

7-1/2"9-1/2"
9"10"
9-7/8"11-1/4"
11-12"
14-1/4"16-1/4"
14-1/2"16"
6-1/2"7-1/4"
7-1/2"8-1/2"

3-1/4"
3-1/2"
4-1/8"
4-1/4"
4-1/2"
5"
3-1/4"
3-1/4"

9-1/4"
10"
10-1/2"
11-1/2"
14-1/2"
14-1/2"
8-7/8"
10-1/4"

ABRTA-5
ABRTA-6
ABRTA-7
ABRTA-8
ABRTA-10G
ABRTA-10J
ABRTA-5
ABRTA-5

AB18-0
AB30-0
AB36-0
AB36-0
N/A
N/A
AB18-0
AB18-0

PJ50032
PJ50033
PJ50034
PJ50035
PJ50036
PJ50063
PJ50128
PJ50129

Product Guide

193

RSAH
Anchor Base Poles
Round Straight Aluminum, Hinged

P R O D U C T

O V E R V I E W

Intended Use
For 10 to 20 mounting height.

Anchor Bolts Top 12" galvanized per ASTM A-153. Made of carbon
steel bar having a minimum-yield strength of 55,000 PSI.

Features

Grounding Base plate tapped for 3/8-16 UNC ground bolt (provided
by others).

Shaft One-piece extruded 6063 aluminum alloy with a T6 temper.


Circumferential satin-brushed finish. The round, straight tube is
uniform in cross-section down the length of the shaft.

Handhole Available as an option, and located 90o to the right of the


hinge.

Hinged Anchor Base Cast from A356 aluminum alloy, the anchor
base is heat-treated to a T6 temper. The shaft inserts into the tilting
section of the hinged base and is joined together by continuous
circumferential welds at the outside top and inside bottom. The tilting
and anchored sections of the hinged base are joined by a 3/4"
diameter solid aluminum pivot rod. The tilting section of the hinged
base is held in a vertical position by three 1/2"-13 x 2 1/2" stainless
steel hex head bolts which attach to stainless steel inserts cast into
the aluminum base. A cast-aluminum two-piece cover is included.

Hardware Stainless steel.


Top Cap Removable cast-aluminum top cap is provided for drill
mount poles.
Finish Standard finish is brushed aluminum. Optional polyester
powder painted and anodized finishes available.

Ordering Information: See page 191


(Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust

INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately upon delivery to
prevent finish damage.

Catalog
Number
RSAH 10 4C
RSAH 14 4C
RSAH 14 5E
RSAH 16 4C
RSAH 16 5C
RSAH 16 6E
RSAH 18 5C
RSAH 18 5G
RSAH 20 5C
RSAH 20 5G
RSAH 20 6G

Nom.
Pole
Wall
mount. Shaft Size Thick.
ht. (ft.) (in. x in. x ft.) (in.)
10
14
14
16
16
16
18
18
20
20
20

4 x 4 x 10
4 x 4 x 14
5 x 5 x 14
4 x 4 x 16
5 x 5 x 16
6 x 6 x 16
5 x 5 x 18
5 x 5 x 18
5 x 5 x 20
5 x 5 x 20
6 x 6 x 20

0.125
0.125
0.156
0.125
0.125
0.156
0.125
0.188
0.125
0.188
0.188

80
mph

90
mph

100
mph

Max.
wt.

Bolt
Circle
(in.)

8.2
4.4
10.6
3.1
6.2
13.8
4.5
8.2
3.2
6.4
11.7

6.1
3.0
8.2
1.9
4.7
10.7
3.3
6.2
2.2
4.8
9.0

4.7
2.1
6.5
1.2
3.6
8.5
2.5
4.9
1.6
3.7
7.1

100
100
100
100
100
100
130
130
130
130
130

8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10

Bolt
Approx.
Size
ship wt.
(in. x in. x in.) (lbs)
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3

NOTES:
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
Options: See page 202
Brackets: See page 203-204

Pole Data
Tapped 3/8 - 16 for ground connector

194

Product Guide

Shaft
Base
size

Bolt
circle
A

Bolt
projection
B

Base
square
C

Warehouse
Anchor Bolt
description

Template
number

4"
5"
6"

8-1/2"10"
8-1/2"10"
8-1/2"10"

3-1/2"
3-1/2"
3-1/2"

12-5/8"
12-5/8"
12-5/8"

AB18-0
AB18-0
AB30-0

PJ50060
PJ50061
PJ50062

For more information please visit our website:


www.americanelectriclighting.com

43
50
66
54
60
88
65
90
69
97
110

SSA
Anchor Base Poles
Square Straight Aluminum

P R O D U C T

O V E R V I E W

Intended Use
For 4, 5 or 6 shaft width, 8 to 35 mounting height.

Grounding Ground lug located immediately inside handhole is


tapped for 3/8"-16 UNC ground bolt (provided by others).

Features
Shaft Square, non-tapered shaft made from extruded 6063-T6 or
6061-T6 aluminum alloy Shaft width is 4, 5 or 6 inches. Wall thickness
is .125, .188 or .250, depending on mounting height and loading
requirements.
Anchor Base Cast from 356-T6 aluminum alloy. Anchor bolt holes
are recessed and covered by aluminum caps.
Anchor Bolts Top 12" galvanized per ASTM A-153. Made of 3/4" or 1"
diameter steel rod having minimum-yield strength of 55,000 psi.

Handhole Reinforced handhole having nominal dimensions 2" x 4"


(4" sq.) or 2 1/2 x 4" (5" or 6" sq.). Handhole cover plate made from
aluminum alloy with attachment hardware provided.
Hardware Stainless steel.
Top Cap Removable cast-aluminum top cap is provided for drill
mount poles.
Finish Brushed aluminum is standard; optional polyester powder
paint and anodized finishes available.
Bolt Covers Nut covers included with each anchor base.

Ordering Information: See page 191


(Note: Poles are available only in U.S.)

Technical Information
EPA (ft ) with 1.3 gust
2

Catalog
Number
SSA 8 4C
SSA 10 4C
SSA 12 4C
SSA 14 4C
SSA 15 4C
SSA 16 4C
SSA 16 4G
SSA 16 5G
SSA 18 4C
SSA 18 4G
SSA 18 5G
SSA 20 4C
SSA 20 4G
SSA 20 5G
SSA 20 6G
SSA 20 6J
SSA 25 5G
SSA 25 6G
SSA 25 6J
SSA 30 6G
SSA 30 6J
SSA 32 6J
SSA 35 6J
SSA 35 7J

Nom.
Pole
Wall
mount. Shaft Size Thick.
ht. (ft.) (in. x in. x ft.) (in.)
8
10
12
14
15
16
16
16
18
18
18
20
20
20
20
20
25
25
25
30
30
32
35
35

4.0 x 8.0
4.0 x 10.0
4.0 x 12.0
4.0 x 14.0
4.0 x 15.0
4.0 x 16.0
4.0 x 16.0
5.0 x 16.0
4.0 x 18.0
4.0 x 18.0
5.0 x 18.0
4.0 x 20.0
4.0 x 20.0
5.0 x 20.0
6.0 x 20.0
6.0 x 20.0
5.0 x 25.0
6.0 x 25.0
6.0 x 25.0
6.0 x 30.0
6.0 x 30.0
6.0 x 32.0
6.0 x 35.0
6.0 x 35.0

0.125
0.125
0.125
0.125
0.125
0.125
0.188
0.188
0.125
0.188
0.188
0.125
0.188
0.188
0.188
0.250
0.188
0.188
0.250
0.188
0.250
0.250
0.250
0.250

80
mph

90
mph

100
mph

Max.
wt.

Bolt
Circle
(in.)

16.5
11.5
12.4
9.3
8.0
6.9
11.8
15.0
4.9
9.2
16.8
3.3
7.0
13.6
22.0
30.4
7.2
13.2
19.7
7.0
12.2
9.7
6.4
7.6

12.6
8.6
9.2
6.7
5.6
4.7
8.5
11.1
3.0
6.4
12.2
1.7
4.6
9.5
15.9
22.6
4.2
8.6
13.8
3.4
7.5
5.4
2.6
3.1

9.9
6.5
6.9
4.8
3.9
3.1
6.2
7.5
1.7
4.4
8.9
0.5
2.9
6.6
11.6
17.0
2.0
5.4
9.5
0.8
4.1
2.3

300
230
160
120
100
90
130
280
70
100
230
40
80
180
230
300
110
180
250
130
170
160
200
150

8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
10-1/2-11-1/2
8-1/2-9-5/8
8-1/2-9-5/8
10-1/2-11-1/2
8-1/2-9-5/8
8-1/2-9-5/8
10-1/2-11-1/2
12-13
12-13
10-1/2-11-1/2
12-13
12-13
12-13
12-13
12-13
12-13
14-1/815-1/8

Bolt
Approx.
Size
ship wt.
(in. x in. x in.) (lbs.)
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4

32
37
40
50
52
54
74
83
57
80
91
62
85
107
155
202
130
180
224
210
258
272
294
290

INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately upon delivery to
prevent finish damage.

Tapered 3/8-16 for


ground connector

NOTES:
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
Options: See page 202
Brackets: See page 203-204

Pole Data
ShaftBolt
Base
size

Bolt
circle
A

Base
projection
B

Anchor
square
C

Anchor Bolt
description

Template
number

4"C
4"G
5"
6"
7"

8-1/29-5/8"
8-1/29-5/8"
10-1/211-1/2"
12"-13"
14-1/815-1/8"

3-1/8"
3-1/8"
3-1/4"
4"
4-1/4"

9-15/16"
9-15/16"
11-9/16"
12-1/4"
15-1/8"

AB18-0
AB30-0
AB30-0
AB36-0
AB36-0

PJ50045
PJ50045
PJ50046
PJ50044
PJ50130

Product Guide

195

SSAH
Anchor Base Poles
Square Straight Aluminum, Hinged

P R O D U C T

O V E R V I E W

Intended Use
Anchor Bolts Top 12" galvanized per ASTM A-153. Made of 3/4
diameter steel rod having minimum-yield strength of 55,000 psi.

For 10 to 20 mounting height.

Features

Grounding Base plate tapped for 3/8-16 UNC ground bolt (provided
by others).

Shaft Square, non-tapered shaft made from extruded 6063-T6


aluminum alloy. Shaft width is 4 or 5 inches. Wall thickness is .125 or
.188 depending on mounting height and loading requirements.

Handhole Available as an option, and located 90o to the right of the


hinge.

Hinged Anchor Base Cast from A356 aluminum alloy and heat
treated to a T6 temper. The shaft inserts into the tilting section of the
hinged base and is joined together by continuous circumferential
welds at the outside top and inside bottom. The tilting and anchored
sections of the hinged base is held in a vertical position by three
1/2"13 x 2 1/2" stainless steel hex head bolts which attach to
stainless steel inserts cast into the aluminum base. A cast-aluminum
two-piece cover is included.

Hardware Stainless steel.


Top Cap Removable cast-aluminum top cap is provided for drill
mount poles.
Finish Brushed aluminum is standard; optional polyester powder
paint and anodized finishes available.

Ordering Information: See page 191


(Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust

INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately upon delivery to
prevent finish damage.

Catalog
Number
SSAH 10 4C
SSAH 12 4C
SSAH 14 4C
SSAH 15 4C
SSAH 16 4C
SSAH 16 4G
SSAH 18 4C
SSAH 18 4G
SSAH 18 5G
SSAH 20 4G
SSAH 20 5G

Nom.
Pole
Wall
mount. Shaft Size Thick.
ht. (ft.) (in. x in. x ft.) (in.)
10
12
14
15
16
16
18
18
18
20
20

4 x 4 x 10
4 x 4 x 12
4 x 4 x 14
4 x 4 x 15
4 x 4 x 16
4 x 4 x 16
4 x 4 x 18
4 x 4 x 18
5 x 5 x 18
4 x 4 x 20
5 x 5 x 20

0.125
0.125
0.125
0.125
0.125
0.188
0.125
0.188
0.188
0.188
0.188

80
mph

90
mph

100
mph

Max.
wt.

Bolt
Circle
(in.)

13.1
9.6
7.0
6.0
5.0
8.9
3.4
6.8
12.6
5.0
9.9

9.9
7.0
4.9
4.0
3.2
6.2
1.8
4.5
8.8
3.0
6.6

7.5
5.1
3.3
2.6
1.9
4.3
0.7
2.9
6.1
1.6
4.2

100
100
100
100
100
150
100
100
150
150
175

8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
9-5/16-10
8-1/2-10
9-5/16-10

Bolt
Approx.
Size
ship wt.
(in. x in. x in.) (lbs.)
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3

NOTES:
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
Options: See page 202
Brackets: See page 203-204

Pole Data

196

Product Guide

Shaft
Base
size

Bolt
circle
A

Bolt
projection
B

Base
square
C

Warehouse
Anchor Bolt
description

Template
number

4"C
4"G
5"

8-1/210"
8-1/210"
9-5/1610"

3-1/2"
3-1/2"
3-1/2"

11-11/16"
11-11/16"
11-11/16"

AB18-0
AB30-0
AB30-0

PJ50055
PJ50055
PJ50056

For more information please visit our website:


www.americanelectriclighting.com

48
53
57
60
62
86
67
93
108
100
117

RSS
Anchor Base Poles
Round Straight Steel

P R O D U C T

Intended Use

O V E R V I E W

Anchor Bolts Top 12" is fully galvanized per ASTM A-153. Made of
carbon steel bar with minimum-yield strength of 55,000 psi.

For 8 to 30 mounting height.

Grounding Nut holder located immediately inside handhole is


provided with 1/2-13 UNC ground bolt and nut.

Features

Handhole Nominal 2.5" x 5" handhole is located 18" above base.


Cover and attachment hardware provided.

Shaft Weldable grade A500 or A513 carbon steel tubing with minimum
yield of 46,000 or 42,000 psi. Uniform wall thickness of .120". Shafts are
one-piece construction with a full length longitudinal, high frequency
electric resistance weld. The round, straight tube is uniform in crosssection down length of shaft.

Hardware Fasteners are high-strength galvanized or zinc-plated or


stainless steel.
Top Cap Removable plastic top cap is provided for drill mount poles.

Anchor Base Fabricated from carbon steel plate (ASTM A-36). 3/4"
thickness. Base plate and shaft are circumferentially welded at both top
and bottom to provide maximum strength at area of critical stress.

Finish Dark bronze polyester powder paint (DDB) standard; optional


polyester powder paint finishes available.
Base Cover Full-base cover finished to match pole.

Ordering Information: See page 191 (Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
RSS 8 4-5B
RSS 8 4-5B
RSS 10 3B
RSS 10 4B
RSS 10 4-5B
RSS 12 3B
RSS 12 4B
RSS 12 4-5B
RSS 14 3B
RSS 14 4B
RSS 14 4-5B
RSS 15 4-5B
RSS 16 3B
RSS 16 4B
RSS 16 4-5B
RSS 18 3B
RSS 18 4B
RSS 18 4-5B
RSS 20 3B
RSS 20 4B
RSS 20 4-5B
RSS 20 5B
RSS 22 4-5B
RSS 25 4B
RSS 25 4-5B
RSS 25 5B
RSS 30 4-5B
RSS 30 5B

Nom.
Pole
Wall
mount. Shaft Size Thick.
ht. (ft.) (in. x in. x ft.) (in.)
8
8
10
10
10
12
12
12
14
14
14
15
16
16
16
18
18
18
20
20
20
20
22
25
25
25
30
30

4.5 x 8.0
4.5 x 8.0
3.0 x 10.0
4.0 x 10.0
4.5 x 10.0
3.0 x 12.0
4.0 x 12.0
4.5 x 12.0
3.0 x 14.0
4.0 x 14.0
4.5 x 14.0
4.5 x 15.0
3.0 x 16.0
4.0 x 16.0
4.5 x 16.0
3.0 x 18.0
4.0 x 18.0
4.5 x 18.0
3.0 x 20.0
4.0 x 20.0
4.5 x 20.0
5.0 x 20.0
4.5 x 22.0
4.0 x 25.0
4.0 x 25.0
5.0 x 25.0
4.5 x 30.0
5.0 x 30.0

0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120

80
mph

Max.
wt.

90
mph

Max.
wt.

100
mph

Max.
wt.

24.7
24.5
10
19.1
24.5
7.7
15.0
19.8
6.0
12.2
16.2
12.0
4.6
9.6
13.1
3.4
7.6
10.5
2.4
6.0
8.5
11.75
6.0
2.85
4.8
7.25
2.3
4.2

630
615
250
480
615
195
390
495
175
305
405
300
125
250
330
90
190
265
100
150
215
300
150
100
130
180
80
150

19.7
19.5
7.7
15.0
19.5
5.8
11.8
15.7
4.4
9.4
12.8
9.5
3.2
7.4
10.2
2.3
5.7
8.2
1.4
4.45
6.6
9.1
4.5
1.95
3.6
5.5
1.5
3

495
490
190
375
490
145
300
395
130
250
320
250
100
185
265
60
180
210
75
150
165
230
125
75
90
150
75
125

16.0
15.8
6.0
12.2
15.8
4.4
9.5
12.7
3.3
7.6
10.3
7.5
2.3
5.9
8.2
1.4
4.5
6.5

3.45
5.2
7.25
3.75
1.35
2.7
4.25
1.0
2.25

430
395
175
305
395
130
240
320
90
195
260
200
60
150
205
70
130
165

125
130
180
100
75
90
150
60
100

Bolt
Bolt
Approx.
Circle
Size
ship wt.
(in.) (in. x in. x in.) (lbs.)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3

55
55
55
70
75
60
80
85
70
90
95
96
80
100
105
90
110
115
100
120
130
145
134
145
145
180
185
210

Nut Holder
Handhole Cover

INSTALLATION NOTES:

Pole Data
Shaft
Base
size

Bolt
circle
A

Bolt
projection
B

Base
square
C

Warehouse
Anchor Bolt
description

Template
number

3
4"
4-1/2"
5"

8"
8"
8"
8"

3-1/4" x 3-1/2"
3-1/4" x 3-1/2"
3-1/4" x 3-1/2"
3-1/4" x 3-1/2"

8"
8"
8"
8"

AB18-0
AB18-0
AB18-0
AB18-0

PJ50041
PJ50041
PJ50041
PJ50041

NOTES:
Mounting Arrangement: (PT) Open Top (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180

Installation requires grout to be packed under base to ensure full contact


with foundation. Factory-supplied templates must be used when setting
anchor bolts. American Electric Lighting will not accept claim for incorrect
anchorage placement due to failure to use American Electric Lighting
factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must be removed
immediately upon delivery to prevent finish damage.

3 Options: see page 202


4 Brackets: See page 203-204

Product Guide

197

RTS
Anchor Base Poles
Round Tapered Steel

P R O D U C T

O V E R V I E W

Intended Use
For 20 to 50 mounting height.

Grounding Nut holder located immediately inside handhole is


provided with 1/2-13 UNC ground bolt and nut.

Features
Shaft Minimum weldable-grade (ASTM A-595 Grade A), hot-rolled,
commercial-quality carbon steel tubing with minimum yield of 55,000
psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793").
Shafts are constructed with full-length, longitudinal, high-frequency
resistance weld. Round in cross-section, having uniform taper of
approximately .14" per foot.
Anchor Base Fabricated from hot-rolled carbon steel plate that
conforms to ASTM A36.
Handhole Reinforced handhole rim having nominal dimensions of
3"x5" for shafts less than 6.25" base diameter and 4"x6.5" for all other
shafts. Steel cover with attachment screws included. Handhole is
located 18" above base.
Ordering Information:
See page 191
(Note: Poles are available only
in U.S.)
INSTALLATION NOTES:
Installation requires grout to be packed
under base to ensure full contact with
foundation. Factory-supplied templates
must be used when setting anchor
bolts. American Electric Lighting will
not accept claim for incorrect
anchorage placement due to failure to
use American Electric Lighting factory
templates.
Do not erect poles without having
fixtures installed.
If poles are stored outside, all
protective wrapping must be removed
immediately upon delivery to prevent
finish damage.

Anchor Bolts Fabricated from commercial-quality hot-rolled carbon


steel with minimum yield strength of 55,000 psi. Bolts have an "L" bend
on one end.
Hardware Fasteners are high-strength galvanized or zinc-plated or
stainless steel.
Top Cap Removable top cap provided with all drill-mount poles.
Finish Dark bronze polyester powder finish (DDB) standard; other
architectural colors available.
Bolt Cover Bolt covers are zinc diecast and fasten to shaft by a .25
stainless steel, self tapping hexhead screw. Full base cover available
as option.

Technical Information
EPA (ft2) with 1.3 gust
Nom.
Pole
Wall
mount. Shaft Size Thick.
ht. (ft.) (in. x in. x ft.) (in.)

Catalog
Number
RTS 20 5-9B
RTS 20 6-5B
RTS 25 5-9B
RTS 25 7-0B
RTS 25 7-0F
RTS 30 6-6B
RTS 30 8-0B
RTS 30 8-0F
RTS 35 7-3B
RTS 35 8-5B
RTS 35 9-5B
RTS 39 7-8B
RTS 39 9-0B
RTS 39 9-0F
RTS 45 10-0B
RTS 45 10-0F
RTS 50 10-0B
RTS 50 10-0F

20
20
25
25
25
30
30
30
35
35
35
39
39
39
45
45
50
50

5.9 x 3.1 x 20
6.5 x 3.7 x 20
5.9 x 2.4 x 25
7.0 x 3.5 x 25
7.0 x 3.5 x 25
6.6 x 2.4 x 30
8.0 x 3.8 x 30
8.0 x 3.8 x 30
7.3 x 2.4 x 35
8.5 x 3.6 x 35
9.5 x 4.6 x 35
7.8 x 2.4 x 39
9.0 x 3.6 x 39
9.0 x 3.6 x 39
10.0 x 3.7 x 45
10.0 x 3.7 x 45
10.0 x 3.0 x 50
10.0 x 3.0 x 50

0.125
0.125
0.125
0.125
0.188
0.125
0.125
0.188
0.125
0.125
0.125
0.125
0.125
0.188
0.125
0.188
0.125
0.188

Gauge

80
mph

Max.
wt.

90
mph

Max.
wt.

100
mph

Max.
wt.

11
11
11
11
7
11
11
7
11
11
11
11
11
7
11
7
11
7

19.3
24.2
12.5
20.3
28.5
11.7
18.9
27.5
11.2
18.9
23.2
10.7
17.2
28.5
17.4
28.5
13.2
20.5

482
605
312
507
760
292
473
838
280
472
580
267
430
715
435
715
330
512

15.1
19.3
9.9
16.2
24.0
9.3
14.9
27.0
8.9
15.1
18.2
8.5
13.5
23.0
13.5
23.0
10.6
16.5

377
482
247
405
625
232
373
675
222
377
455
212
338
575
338
575
265
412

12.2
15.6
8
13.1
19.8
7.5
12
22.0
7.1
12.2
14.5
6.6
10.8
19.0
10.6
19.0
8.3
13.6

305
390
200
327
495
187
300
550
177
305
363
165
270
475
265
475
208
340

Bolt
Bolt
Approx.
Circle
Size
ship wt.
(in.) in. x in. x in.) (lbs.)
9.0
9.5
9.0
10.0
10.0
9.5
11.0
11.0
10.5
11.5
13.0
11.0
12.5
12.5
13.5
13.5
13.5
13.5

1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1-1/4 x 42 x 6
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1-1/4 x 42 x 6
1 x 36 x 4
1-1/4 x 42 x 6
1 x 36 x 4
1-1/4 x 42 x 6

140
160
155
200
280
200
265
380
250
315
370
285
355
515
450
650
475
680

Pole Data
Shaft
Base
size

NOTES:
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
Options: See page 202
Brackets: See page 203-204

198

Product Guide

5.9" B
6.5" B
7.0" B
7.0" F
6.6" B
8.0" B
8.0" F
7.3" B
8.5" B
9.5" B
7.8" B
9.0" B
9.0" F
10.0" B
10.0" F

Bolt
Circle
A
9"
9.5"
10"
10"
9.5"
11"
11"
10.5"
11.5"
13"
11"
12.5"
12.5"
13.5"
13.5"

Bolt
Projection
B

Base
Square
C

Warehouse
Bolt
description

3-1/2"4-1/4"
3-1/2"4-1/4"
3-1/2"4-1/4"
3-3/4"4-1/2"
3-1/2"4-1/4"
3-1/2"4-1/4"
4-1/25-1/4"
3-1/2"4-1/4"
3-3/4"4-1/2"
3-3/4"4-1/2"
3-3/4"4-1/2"
3-3/4"4-1/2"
4-1/25-1/4"
3-3/4"4-1/2"
4-1/25-1/4"

10"
10-1/2"
10-7/8"
10-7/8"
10-1/2"
11-1/2"
11-1/2"
11-1/4"
12"
13"
11-1/2"
12-3/8"
12-3/8"
14"
14"

AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
N/A
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
N/A
AB36-0
N/A

For more information please visit our website:


www.americanelectriclighting.com

Template
Number

PJ50075
PJ50074
PJ50077
PJ50076
PJ50078
PJ50079
PJ50080
PJ50081
PJ50082
PJ50083
PJ50084
PJ50085
PJ50086
PJ50087
PJ50088

SSS
Anchor Base Poles
Square Straight Steel

P R O D U C T

O V E R V I E W

Intended Use
For 10 to 39 mounting height.

Anchor Bolts Top 12" galvanized per ASTM A-153. Made of 3/4" or 1"
diameter steel rod having a minimum-yield strength of 55,000 psi.

Features

Grounding Nut holder located immediately inside handhole rim is


provided with a 1/2" x13 UNC ground bolt and nut (by others).

Shaft Weldable grade, hot-rolled, commercial-quality carbon steel


tubing with a minimum yield of 55,000 psi (11-gauge), 50,000 psi (7gauge). Uniform wall thickness of .125" or .188". Shaft is one-piece with
a full-length, longitudinal, high frequency electric resistance weld.
Uniformly square in cross-section with flat sides, small corner radii
and excellent torsional qualities. Available shaft widths are 4, 5 and 6
inches.

Handhole 1/2-13, Reinforced handhole rim having nominal


dimensions of 3"x5" for all shafts. Includes steel cover with
attachment screws.

Anchor Base Fabricated from hot-rolled carbon steel plate that


meets or exceeds a minimum-yield strength of 36,000 psi. The anchor
base is provided with slotted holes.

Finish Dark bronze polyester powder paint (DDB) standard; optional


polyester powder paint finishes available.

Hardware Fasteners are high-strength, galvanized or zinc-plated or


stainless steel.
Top Cap Removable top cap is provided for drill mount poles.

Base Cover Full-base cover finished to match pole.


INSTALLATION NOTES:

Ordering Information: See page 191 (Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust
Nom.

Pole

Catalog

mount. Shaft Size

Number

ht. (ft.) (in. x in. x ft.)

SSS 10 4C
SSS 12 4C
SSS 14 4C
SSS 16 4C
SSS 18 4C
SSS 20 4C
SSS 20 4G
SSS 20 5C
SSS 20 5G
SSS 25 4C
SSS 25 4G
SSS 25 5C
SSS 25 5G
SSS 30 4G
SSS 30 5C
SSS 30 5G
SSS 30 6G
SSS 35 5G
SSS 35 6G
SSS 39 6G

10
12
14
16
18
20
20
20
20
25
25
25
25
30
30
30
30
35
35
39

4.0 x 10.0
4.0 x 12.0
4.0 x 14.0
4.0 x 16.0
4.0 x 18.0
4.0 x 20.0
4.0 x 20.0
5.0 x 20.0
5.0 x 20.0
4.0 x 25.0
4.0 x 25.0
5.0 x 25.0
5.0 x 25.0
4.0 x 30.0
5.0 x 30.0
5.0 x 30.0
6.0 x 30.0
5.0 x 35.0
6.0 x 35.0
6.0 x 39.0

Wall
Thick.

80

Max.

90

Max.

100

Max.

(in.)

Gauge

mph

wt.

mph

wt.

mph

wt.

0.125
0.125
0.125
0.125
0.125
0.125
0.188
0.125
0.188
0.125
0.188
0.125
0.188
0.188
0.125
0.188
0.188
0.188
0.188
0.188

11
11
11
11
11
11
7
11
7
11
7
11
7
7
11
7
7
7
7
7

30.6
24.4
19.9
15.9
12.6
9.6
14.0
17.7
28.1
4.8
10.8
9.8
18.5
6.0
4.7
10.7
19.0
5.9
12.4
7.2

765
610
498
398
315
240
350
443
703
150
270
245
463
150
150
267
475
150
310
180

23.8
18.8
15.1
11.8
9.2
6.7
11.0
12.7
21.4
2.6
7.7
6.3
13.3
4.0
2.0
6.7
13.2
2.5
7.6
3.0

595
470
378
295
230
167
275
343
535
100
188
157
333
100
50
167
330
100
190
75

18.9
14.8
11.7
8.9
6.7
4.5
8.0
9.4
16.2
1.0
5.4
3.7
9.5
2.5

3.9
9.0

4.2

473
370
293
223
168
150
200
235
405
50
135
150
238
75

100
225

105

Bolt

Bolt

Approx.

Circle

Size

ship wt.

(in.) (in. x in. x in.) (lbs.)


89
89
89
89
89
89
89
1012
1012
89
89
1012
1012
89
1012
1012
1113
1012
1113
1113

3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
3/4 x 18 x 3
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4

75
90
100
115
125
140
198
185
265
170
245
225
320
295
265
380
520
440
540
605

Installation requires grout to be packed


under base to ensure full contact with
foundation. Factory-supplied templates
must be used when setting anchor
bolts. American Electric Lighting will
not accept claim for incorrect
anchorage placement due to failure to
use American Electric Lighting
factory templates.
Do not erect poles without having
fixtures installed.
If poles are stored outside, all
protective wrapping must be removed
immediately upon delivery to prevent
finish damage.

Pole Data
Shaft
Base
size

Bolt
circle
A

Bolt
projection
B

Base
square
C

Warehouse
Anchor Bolt
description

Template
number

4"C
4"G
5"
6"

8-1/2"
8-1/2"
10"12"
11"13"

2-3/4"4"
2-3/4"4"
3-3/8"4"
3-3/8"4"

8"
8"
11"
12-1/2"

AB18-0
AB30-0
AB36-0
AB36-0

PJ50004
PJ50004
PJ50010
PJ50011
NOTES:
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D.
(2" NPS)
Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
Options: See page 202
Brackets: See page 203-204

Product Guide

199

STS
Anchor Base Poles
Square Tapered Steel

P R O D U C T

O V E R V I E W

Intended Use
For 20 to 50 mounting height.

Grounding Nut holder located immediately inside handhole rim is


tapped for a 1/2" 13 UNC ground bolt and nut (by others).

Features

Handhole Reinforced handhole rim having nominal dimensions of


3"x5" for shafts less than 6.375" square and 4"x6.5" for all other shafts.
Steel cover with attachment screws included. Handhole is located 18"
above base.

Shaft Weldable-grade (ASTM A595 Grade A) hot-rolled commercialquality carbon steel tubing with minimum yield of 55,000 psi. Uniform
wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are
constructed with full-length longitudinal high-frequency resistance
weld and are square in cross-section, having flat sides, radiused
corners and a uniform taper of approximately .11" per foot.
Anchor Base Fabricated from hot-rolled carbon steel plate that
conforms with ASTM A36.
Anchor Bolts Fabricated from commercial-quality, hot-rolled carbon
steel with minimum-yield strength of 55,000 psi. Bolts have an "L" bend
on one end.

Ordering Information:
See page 191
(Note: Poles are available only
in U.S.)

Hardware Fasteners are high-strength galvanized or zinc-plated or


stainless steel.
Top Cap Removable top cap provided with all drill-mount poles.
Finish Must specify finish.
Base Cover Full-base cover finished to match pole.

Technical Information
EPA (ft2) with 1.3 gust
Nom.
Pole
mount. Shaft Size
ht. (ft.) (in. x in. x ft.)

Catalog
Number

Wall
Thick.
(in.) Gauge

80
mph

Max.
wt.

90
mph

Max.
wt.

100
mph

Max.
wt.

0.125
0.188
0.125
0.188
0.125
0.188
0.125
0.188
0.125
0.188
0.188
0.188
0.188

18.0
30.5
16.8
28.5
13.6
23.6
10.7
23.4
8.6
19.3
16.0
23.5
19.4

452
764
422
713
340
590
269
585
215
483
400
588
485

13.8
24.0
12.6
22.5
9.8
17.9
7.3
17.4
5.4
14.2
11.1
16.6
13.2

345
602
315
563
245
448
184
435
135
355
278
415
332

10.7
19.0
9.5
18.2
7.0
13.7
4.8
13.0
3.0
10.4
7.4
11.4
8.7

268
477
238
455
175
343
120
325
75
260
187
287
218

Bolt
Bolt
Approx.
Circle
Size
ship wt.
(in.) (in. x in. x in.) (lbs.)

INSTALLATION NOTES:
Installation requires grout to be
packed under base to ensure full
contact with foundation. Factorysupplied templates must be used
when setting anchor bolts. American
Electric Lighting will not accept claim
for incorrect anchorage placement
due to failure to use American Electric
Lighting factory templates.
Do not erect poles without having
fixtures installed.
If poles are stored outside, all
protective wrapping must be removed
immediately upon delivery to prevent
finish damage.

STS 20 5-2B
STS 20 5-5F
STS 25 6-0B
STS 25 6-4F
STS 30 6-4B
STS 30 6-4F
STS 35 6-8B
STS 35 7-1F
STS 39 7-1B
STS 39 7-1F
STS 45 7-8F
STS 45 8-7F
STS 50 8-8F

20
20
25
25
30
30
35
35
39
39
45
45
50

5.25 x 3.05 x 20
5.50 x 3.30 x 20
6.00 x 3.25 x 25
6.41 x 3.66 x 25
6.41 x 3.11 x 30
6.41 x 3.11 x 30
6.81 x 2.96 x 35
7.13 x 3.28 x 35
7.18 x 2.92 x 39
7.13 x 2.87 x 39
7.88 x 2.93 x 45
8.75 x 3.80 x 45
8.81 x 3.31 x 50

11
7
11
7
11
7
11
7
11
7
7
7
7

10-3/4 1 x 36 x 4
11
1 x 36 x 4
12
1 x 36 x 4
12-1/2 1 x 36 x 4
12-1/2 1 x 36 x 4
12-1/2 1 x 36 x 4
13
1 x 36 x 4
13-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
14-1/2 1 x 36 x 4
15-3/4 1-1/4 x 42 x 6
16 1-1/4 x42 x 6

NOTES:
1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
2 Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
3 Options: See page 202
4 Brackets: See page 203-204

Pole Data

200

Product Guide

Shaft
Base
size

Bolt
Circle
A

Bolt
Projection
B

Base
Square
C

Warehouse
Anchor Bolt
description

Template
Number

5.2" B
5.5" F
6.0" B
6.4" F
6.4" B
6.8" B
7.1" F
7.1" B
7.8" F
8.7" F
8.8" F

10-3/4"
11"
12"
12-1/2"
12-1/2"
13"
13-1/2"
13-1/2"
14-1/2"
15-3/4"
16"

3-1/24-1/4"
3-3/4"4-1/2"
3-1/24-1/4"
4"4-3/4"
3-1/24-1/4"
3-1/24-1/4"
4-1/4"5"
3-1/24-1/4"
4"4-3/4"
4-3/4"5-1/2"
4-1/25-1/4"

10-3/4"
11"
11-1/2"
11-7/8"
11-7/8"
12-1/4"
12-5/8"
12-5/8"
13-3/8"
14-1/4"
15-1/2"

AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB42-0
AB42-0

PJ50095
PJ50096
PJ50097
PJ50098
PJ50099
PJ50101
PJ50102
PJ50103
PJ50105
PJ50106
PJ50107

For more information please visit our website:


www.americanelectriclighting.com

155
235
205
310
260
375
305
475
345
500
620
730
780

STSH
Anchor Base Poles
Square Tapered Steel Hinge

P R O D U C T

O V E R V I E W

Intended Use
Anchor Bolts Fabricated from commercial-quality, hot-rolled carbon
steel with minimum-yield strength of 55,000 psi. Bolts have an "L" bend
on one end.

For 20 to 39 mounting height.

Features

Grounding Nut holder located immediately inside handhole rim is


tapped for a 1/2" 13 UNC ground bolt and nut (provided by others).

Shaft Weldable-grade, hot-rolled, commercial-quality carbon steel


having a guaranteed minimum yield strength of 55,000 psi and is
supplied in 11-gauge (.1196") or 7-gauge (.1793") nominal thickness.
Pole is one-piece construction with full-length, longitudinal, highfrequency, electric-resistance weld. Shaft is square in cross section
having flat sides, radiused corners, and uniform taper of
approximately 11 per foot (4-inch square poles are not tapered).

Handhole Reinforced handhole rim having nominal dimensions of 3"


x 5" for shafts less than 6.375" square and 4" x 6.5" for all other shafts.
Steel cover with attachment screws included. Handhole is located 18"
above base on hinge side.
Hardware Fasteners are high-strength, galvanized or zinc-plated or
stainless steel.

Hinge The hinge includes a stainless steel hinge pin. A flexible


wiring guide is provided, passing through the hinge area for wiring
protection. Hinge is external.

Top Cap Removable top cap provided with all drill-mount poles.
Finish Dark bronze polyester powder finish (DDB) standard; other
architectural colors available.

Anchor Base Fabricated from hot-rolled carbon steel plate that


conforms with ASTM A36.

Base Cover Full-base cover is provided.

Ordering Information: See page 191 (Note: Poles are available only in U.S.)

INSTALLATION NOTES:

Technical Information
EPA (ft ) with 1.3 gust
2

Catalog
Number

Nom.
Pole
Wall
mount. Shaft Size Thick.
80 Max.
ht. (ft.) (in. x in. x ft.) (in.) Gauge mph wt.

STSH 20 4F
STSH 25 4B
STSH 25 6-4B
STSH 30 4F
STSH 30 6-4B
STSH 35 7-1B
STSH 35 7-1F
STSH 39 7-1F

20
25
25
30
30
35
35
39

4 x 4 x 20
4 x 4 x 25
6.41 x 3.63 x 25
4 x 4 x 30
6.41 x 3.08 x 30
7.18 x 2.88 x 35
7.13 x 2.87 x 35
7.13 x 2.87 x 39

0.188
0.188
0.125
0.188
0.125
0.125
0.188
0.188

7
7
11
7
11
11
7
7

11.6
7.1
18.0
4.0
12.5
7.1
22.0
19.5

217
160
254
120
230
160
155
110

90 Max.
mph wt.

100
mph

Max.
wt.

8.5
4.8
13.0
2.1
8.3
3.2
16.9
13.5

6.2
3.1
9.3
0.8
5.1

12.1
9.2

217
160
254
120
230

155
110

217
160
254
120
230
160
155
110

Bolt
Bolt
Approx.
Circle
Size
ship wt
(in.) (in. x in. x in.) (lbs)
8-1/2-10 3/4 x 18 x 3
8-1/2-10 3/4 x 18 x 3
12-1/2 1 x 36 x 4
8-1/2-10 3/4 x 18 x 3
12-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4

300
370
355
435
440
540
700
740

Installation requires grout to be packed under


base to ensure full contact with foundation.
Factory-supplied templates must be used
when setting anchor bolts. American Electric
Lighting will not accept claim for incorrect
anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures
installed.
If poles are stored outside, all protective
wrapping must be removed immediately upon
delivery to prevent finish damage.

External Hinge Detail

NOTES:
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
Options: See page 202
Brackets: See page 203-204

Pole Data
Shaft
Base
size
4.0" F
6.4" B
7.1" F
7.1" B

Bolt
Circle
A

Bolt
Projection
B

8-1/210" 3-1/24-1/4"
12-1/2" 3-3/4"4-1/2"
13-1/2"
4"4-3/4"
13-1/2" 3-1/24-1/4"

Base
Square
C

Warehouse
Anchor Bolt
description

Template
Number

9-3/4"
11-7/8"
12-5/8"
12-5/8"

AB18-0
AB36-0
AB36-0
AB36-0

PJ50091
PJ50092
PJ50093
PJ50094

Winch Detail (accessory)

Winch Ordering
Family

Winch

Shaft size

Order nomenclature

STSH

WCH

4F or 4B
6-4B
7-1B
7-1F

STSHWCH 4F
STSHWCH 6-4B
STSHWCH 7-1B
STSHWCH 7-1F

Product Guide

201

Pole Options
P R O D U C T

O V E R V I E W

Anchor Bolts

Horizontal Arm Bracket

Available in various sizes for use with American Electric Lighting poles. Set
includes hex nuts and washers. Anchor bolt is partially galvanized for exposed
threads per ASTM-A153. Bolts have minimum-yield strength rating of 55,000
psi, AASHTO M314 GR55. See individual
pole catalog pages for anchor bolt
sizes and description.

Single or twin side-mounted horizontal arm brackets for additional


luminaires. Made from 2 3/8," pipe. Upright is 18" from pole; special arm
lengths may be available upon request. Arms are rated for luminaires up to
4.5 sq. ft. EPA and 100 lbs. per arm. When ordering, specify location in height
and feet above base of pole and orientation from the handhole.

Base Covers

Option

Two-piece, full-base cover. Four fasteners provided to secure pieces together.


Finished to match pole. Shipped separately. Standard with steel poles only.

H1-18A Aluminum
H1-18S Steel
HI-18F Fiberglass
HI-18C Concrete

Option

Pole

(square)
Dimension

(depth)
Dimension

SBC4
SBC5
SBC6

SSS 4"
SSS 5"
SSS 6"

8.75"
11.44"
13.5"

x 5.8"
x 6.4"
x 4"

Festoon Outlets
Provision provided for mounting duplex outlet. When ordering, specify location
in height and feet above base of pole and orientation from the handhole.
Description

FDL

Festoon Duplex Outlet, Less Electric

Handheld Cover Plates

Note: SSS and SSA arm attachment is slightly


different from RTA. Arm modifications located
on pole to accept arms. Arms shipped as
separate item.

It has been found that steady 10-30 mph winds


sometimes induce second or higher mode of vibration
in lighting poles. Second mode vibration is
characterized by the maximum periodic motion
occurring at approximately the mid-height of the pole.
This type of vibration can result in failure of the pole
and/or luminaire. There is no method of predicting
destructive light pole vibration. Vibration dampers
which alleviate this condition are available. Shipped
installed.

Four nut covers are standard for RSA, RTA and RTS
poles only.

All other poles order as handhole cover for full pole


description. Also specify if pole is existing.

Tenon Dimensions.

Bolt-on Tenon Square Steel Poles

Tenon Mounting Slipfitters

(Order separately)
Number of fixtures

Tenon O.D.

One

Two@180

2-3/8"
2-7/8"
4"

T20-190
T25-190
T35-190

T20-280
T25-280
T35-280

Two@90 Three@120 Three@90 Four@90


T20-290
T25-290
T35-290

T20-320
T25-320
T35-320

T20-390
T25-390
T35-390

T20-490
T25-490
T35-490

Threaded couplings and/or nipples can be factory installed. When ordering,


specify location in height and side of pole (ex: A, B, C, D).
threaded coupling
threaded coupling
threaded coupling

Product Guide

NPL12
NPL34
NPL1

1/2"
3/4"
1"

threaded nipple
threaded nipple
threaded nipple"

Cat. No.

Wt. (lbs.)

SBT-4S1
SBT-5S1
SBT-6S2

2-3/8"
2-3/8"
2-3/8"

3"
4"
5"

13-3/4"
13-3/4"
13-3/4"

5"
5"
5"

7
8
17

Notes:
1
2

Couplings & Nipples

202

7
11
8
9

Nut Covers

SSS HHC: For all SSS poles

1/2"
3/4"
1"

.43
.50
.45
.55

Note: FVD - Field installable vibrator damper available upon


request. Consult factory.

SSS

CPL12
CPL34
CPL1

Weight
(lbs.)

VD - Vibration Damper

For full-base cover on other poles, must order FBC. When ordering separately,
specify full pole nomenclature; i.e., FBC for RTA 25 7E. Also specify if pole is
existing.

Option

EPA
(sq. ft.)

Stocked in distribution centers.


Ordered on a drop-ship basis.

Tamperproof Screws
Tamperproof (TP): Order as TP. Tamperproof screws
provided with base cover.

For more information please visit our website:


www.americanelectriclighting.com

Handhole Opening
Field Installed
Vibration Dampener
Foundation

Aluminum Mounting Brackets


Bullhorns and Spokes - order as separate items

P R O D U C T
Projected area is for bracket only. Bracket projected area is added to
luminaire projected area to get total effective projected area (EPA). All
brackets have a maximum luminaire rating per tenon of 4.5 sq. ft. projected
area and 100 lbs. at a wind velocity of 100 mph (luminaire drag coefficient =
1.0).

O V E R V I E W

Brackets for Aluminum Poles Only


RBA32

RBA28

Finish
Natural aluminum. Optional painted finishes available. Plastic cap supplied.

RBA48

Round Pole
Brackets mount to T25 tenon 2-7/8 O.D., or pole top that is 2-7/8 O.D. Heavy
duty version mounts to T35 tenon 4 O.D.

Catalog
Number

EPA
(sq. ft.)

Weight
(lbs.)

Catalog
Number

EPA
(sq. ft.)

Weight
(lbs.)

RBA28
RBA32
RBA38
RBA48
RBA49

1.2
1.7
1.9
2.7
2.2

7.0
14.3
10.5
14.5
17.5

RBA28 HD
RBA32 HD
RBA38 HD
RBA48 HD
RBA49 HD

1.3
1.7
2.0
2.8
2.2

8.4
12.7
11.9
16.2
15.8

Square Pole

RBA38

RBA49

Brackets for Aluminum Poles Only

Brackets flush mount on 4", 5" and 6" square poles. For use with internal
sleeve, plain open-top poles, American Electric Lighting poles only. Must be
ordered with pole to ensure proper fit.

Catalog
Number

EPA
(sq. ft.)

Weight
(lbs.)

SBA28
SBA38
SBA48
SBA49

0.90
1.50
2.25
1.7

12
17
22
22

SBA38

SBA49
6"

SBA48

SBA28

Product Guide

203

Steel Mounting Brackets


Bullhorns and Spokes - order as separate items

P R O D U C T

O V E R V I E W

Projected area is for bracket only. Bracket projected area is added to


luminaire projected area to get total effective projected area (EPA).
All brackets have a maximum luminaire rating per tenon of 4.5 sq. ft.
projected area and 100 lbs. at a wind velocity of 100 mph (luminaire
drag coefficient = 1.0).

Brackets for Steel Poles Only

BS28

Finish
Dark bronze, standard. Other colors available (consult local American Electric
Lighting representative). Plastic cap supplied.

Standard Hub
Catalog
Number

EPA
(sq. ft.)

Weight
(lbs.)

BS28
BS32
BS38
BS48
BS49

1.0
1.3
1.6
2.3
1.6

21.0
34.0
32.0
44.0
44.0

O.D. 2 7/8 - I.D. 2 1/2


Requires T20 Tenon (min. 5 tall)

Heavy Duty Hub


O.D. 4 1/2 - I.D. 4
Requires T35 Tenon (min. 6 tall)

BS32
BS38

204

Catalog
Number

EPA
(sq. ft.)

Weight
(lbs.)

BS28 HD
BS32 HD
BS38 HD
BS48 HD
BS49 HD

1.3
2.0
2.2
3.4
2.8

28.0
38.0
38.0
47.0
46.0

BS48

BS49

Finish

Brackets for Square Steel Poles Only

Dark bronze, standard.

Requires T20 (2-3/8" max OD) tenon on pole for mounting

Catalog
Number

EPA
(sq. ft.)

Weight
(lbs.)

SBS 28
SBS 38
SBS 49

1.1
1.7
2.1

30.0
42.0
45.0

Product Guide

SBS28

SBS38

For more information please visit our website:


www.americanelectriclighting.com

SBS49

RTF
Anchor Base Poles
Round Tapered Fiberglass

P R O D U C T

O V E R V I E W

Intended Use
For 20 to 45 mounting height.

Hardware Fasteners are high-strength galvanized or zinc-plated or


stainless steel.

Construction

Top Cap Removable top cap provided with all drill-mount poles.

Shaft E type fiberglass reinforced composite shaft incorporating


pigmented, UV inhibiting, thermosetting polyester resin and a smooth
surface finished with a polyurethane surface coat providing a
minimum 1.5 mil dry film thickness.

Finish Ultraviolet resistant and pigmented approximately the same


color as the final polyurethane coating. Must specify color.
Base Cover Full base cover is optional and finished to match pole.

Anchor Base Heavy-duty, A356-T6 aluminum base casting is


permanently bonded to the outside of the fiberglass shaft.
Anchor Bolts Top 12" galvanized per ASTM A-153. Made of 1 or
1-1/4 diameter steel rod having a minimum-yield strength of 55,000 psi.
Handhole An oval, non-metallic, 2 1/2"x5" handhole secured with a
vandal resistant fastener.

Ordering Information:
See page 191 (Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number

INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must
be removed immediately upon delivery to prevent finish
damage.

RTF 20 7-3X
RTF 25 7-3X
RTF 30 8-4X
RTF 30 8-5X
RTF 30 10-5X
RTF 35 8-4X
RTF 35 8-5X
RTF 35 11-2X
RTF 40 11-7X
RTF 40 11-8X
RTF 40 12X
RTF 45 11-7X
RTF 45 11-9X

Nom.
Pole
mount. Shaft Size
ht. (ft.) (in. x in. x ft.)
20
25
30
30
30
35
35
35
40
40
40
45
45

7.3 x 4.6 x 20
7.3 x 4.6 x 25
8.4 x 4.6 x 30
8.5 x 4.8 x 30
10.5 x 6.6 x 30
8.4 x 4.6 x 35
8.5 x 4.8 x 35
11.2 x 6.6 x 35
11.7 x 6.2 x 40
11.8 x 6.4 x 40
12.0 x 6.9 x 40
11.7 x 6.2 x 45
11.9 x 6.6 x 45

80
mph

90
mph

100
mph

Max.
wt.

Bolt
Circle
(in.)

Bolt
Approx.
Size
ship wt.
(in. x in. x in.) (lbs.)

14.4
9.6
11.2
15.6
28.7
5.5
8.5
21.8
6.4
12.2
25.8
3.9
15.2

11.1
7.3
8.5
12.0
22.4
3.8
6.2
16.6
4.3
8.8
19.3
2.0
10.9

8.9
5.7
6.7
9.5
17.4
2.7
4.7
12.5
2.4
6.0
14.3
0.6
7.6

200
200
100
200
300
100
200
300
165
300
300
300
300

11-1/2
11-1/2
11-1/2
11-1/2
14-1/2
11-1/2
11-1/2
15
15-1/2
15-1/2
15-1/2
15-1/2
15-1/2

1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1-1/4 x 36 x 6
1-1/4 x 36 x 6
1-1/4 x 36 x 6
1-1/4 x 36 x 6
1-1/4 x 36 x 6
1-1/4 x 36 x 6

62
75
106
140
202
125
161
248
165
227
317
183
295

Pole Data

4
Bolt Projection

Shaft
Base
size

Bolt
Circle
A

Bolt
Projection
B

Base
Square
C

Template
Number

7.3"
8.4"
8.5"
10.5"
11.2
11.7"
11.8"
11.9"
12.0"

11.5"
11.5"
11.5"
14.5"
15"
15.5"
15.5"
15.5"
15.5"

4"
4"
4"
4"
4"
4"
4"
4"
4"

11"
11"
11"
13.3"
13.5"
14"
14"
14"
14"

PJ50114
PJ50115
PJ50116
PJ50117
PJ50118
PJ50119
PJ50120
PJ50121
PJ50122

NOTES:
1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
2 Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
3 Options: See page 202
4 Brackets: See page 203-204

Product Guide

205

RTFDB
Direct Buried Poles
Round Tapered Fiberglass

P R O D U C T

O V E R V I E W

Intended Use

Hardware Fasteners are high-strength galvanized or zinc-plated or


stainless steel.

For direct burial, 14 to 35 mounting height.

Top Cap Removable top cap provided with all drill-mount poles.
Finish Ultraviolet resistant and pigmented approximately the same
color as the final polyurethane coating. Must specify color.

Construction
Shaft E type fiberglass reinforced composite shaft incorporating
pigmented, UV inhibiting, thermosetting polyester resin and a smooth
surface finished with a polyurethane surface coat providing a
minimum 1.5 mil dry film thickness.
Handhole An oval, non-metallic, 2 1/2"x5" handhole secured with a
vandal-resistant fastener.

Ordering Information: See page 191 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:

Technical Information

Do not erect poles without having fixtures


installed.

EPA (ft2) with 1.3 gust


Catalog
Number
RTFDB 18 6X
RTFDB 20 6-6X
RTFDB 24 6-7X
RTFDB 30 8-3X
RTFDB 30 8-4X
RTFDB 35 8-4X
RTFDB 35 8-5X
RTFDB 41 11-8X

Nom.
mount.
ht. (ft.)

Pole
Shaft Size
(in. x in. x ft.)

80
mph

90
mph

100
mph

14
16
20
25
25
30
30
35

6.0 x 4.1 x 18
6.6 x 4.1 x 20
6.7 x 4.1 x 24
8.3 x 4.4 x 30
8.4 x 4.6 x 30
8.4 x 4.6 x 35
8.5 x 4.9 x 35
11.8 x 6.4 x 41

14.0
10.0
8.2
6.2
14.5
10.5
14.8
14.3

10.4
7.4
5.8
4.7
11.2
8.0
11.4
10.8

7.9
5.5
4.1
3.6
8.9
6.2
9.0
7.8

Approx.
Max. ship wt.
wt.
(lbs.)
150
100
150
100
200
200
300
300

If poles are stored outside, all protective


wrapping must be removed immediately
upon delivery to prevent finish damage.

34
38
46
71
98
116
153
218

NOTES:
1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
2 Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
3 Options: See page 202
4 Brackets: See page 203-204

206

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

SSF
Anchor Base Poles
Square Straight Fiberglass

P R O D U C T

O V E R V I E W

Intended Use
For 6 to 30 mounting height.

Features

Hardware Fasteners are high-strength galvanized or zinc-plated or


stainless steel.

Shaft Constructed by the pultrusion process from thermosetting


polyester resin and contains a minimum of 65 percent "E" type
fiberglass by weight. The fiberglass strands traverse the length of the
pole.

Top Cap Removable top cap provided with all drill-mount poles.

Anchor Base Heavy-duty, A356-T6 aluminum base casting is


permanently bonded to the outside of the fiberglass shaft.

Finish Ultraviolet resistant and pigmented approximately the same


color as the final polyurethane coating. Dark bronze (DDB) is
standard. Must specify color.
Base Cover Full base cover is optional and finished to match pole.

Anchor Bolts Top 12" galvanized per ASTM A-153. Made of 5/8" or 1"
diameter steel rod having a minimum-yield strength of 55,000 psi.
Handhole An oval, non-metallic, 2 1/2" x 5" handhole secured with a
vandal-resistant, stainless steel 1/4" socket head screw.

INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must
be removed immediately upon delivery to prevent finish
damage.

SSF 4 Shaft

Ordering Information: See page 191


(Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
SSF 6 4X
SSF 8 4X
SSF 10 4X
SSF 12 4X
SSF 14 4X
SSF 16 4X
SSF 20 4X
SSF 20 5X
SSF 25 4X
SSF 25 5X
SSF 30 5X
SSF 30 5XHD

Nom.
Pole
mount. Shaft Size
80
ht. (ft.) (in. x in. x ft.) mph
6
8
10
12
14
16
20
20
25
25
30
30

4x4x6
4x4x8
4 x 4 x 10
4 x 4 x 12
4 x 4 x 14
4 x 4 x 16
4 x 4 x 20
5 x 5 x 20
4 x 4 x 25
5 x 5 x 25
5 x 5 x 30
5 x 5 x 30

23.2
16.5
12.0
9.1
6.7
3.7
7.2
12.2
4.2
8.7
4.7
8.6

90
mph

100
mph

Max.
wt.

17.9
12.6
8.9
6.5
4.4
2.2
1.8
9.1
2.5
6.2
2.8
5.1

14.2
9.8
6.7
4.6
2.8
1.1
0.5
6.9
0.75
4.4
1.9
2.6

150
150
150
100
100
100
150
200
150
200
200
200

Bolt
Bolt
Approx.
Circle
Size
ship wt.
(in.) (in. x in. x in.) (lbs.)
8
8
8
8
8
8
8
11
8
11
11
10-12

5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
1 x 30 x 4
5/8 x 21 x 3
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4

18
23
27
31
35
39
80
110
90
115
120
164

Pole Data

SSF 5 Shaft

Shaft
Base
size

Bolt
Circle
A

Bolt
Projection
B

Base
Square
C

Anchor
Bolt
description

Template
Number

4"
5"

8"
11"

3"
4"

7.4"
11.1"

ABSSF-4
ABSSF-5

PJ50123
PJ50124

NOTES:
1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
2 Drill Mounting: (DM19) 1 fixture at 90; (DM28) 2 fixtures at 180
3 Options: See page 202
4 Brackets: See page 203-204

Product Guide

207

STC
Direct Burial Poles
Square Tapered Concrete

P R O D U C T

O V E R V I E W

Intended Use
Handhole A 3"x5" handhole is located 18" above ground line and a 2
1/2" x 7" minimum conduit entrance is located 18" below ground line.
Inserts for the handhole and conduit entrance are non-corrosive and
weatherproof. Handhole frames and covers conform to ASTM-B240.

For direct burial, 16 to 38 mounting height.

Features
Shaft Concrete mix has a minimum 28-day compressive strength of
8,500 PSI and conforms with ASTM-C150. Prestressing steel
reinforcement is uncoated 7 wire, stress relieved strand per ASTMA416. Steel spiral reinforcement conforms to ASTM-A82 and is not
less than .120 (11-gauge) diameter. Poles have a continuous taper of
0.165 inches per foot.

Grounding An 18" long, #4 stranded copper pigtail, connected to


reinforced strand, is provided at pole top and at cable entrance below
grade.
Hardware Fasteners are high-strength galvanized or stainless steel.
Finish Smooth, natural form finish, soft gray color is standard.

Ordering Information: See page 191 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:

Technical Information

Do not erect poles without having fixtures installed.

EPA (ft2) with 1.3 gust


Catalog
Number
STC 13-4X
STC 20 7-24X
STC 20 9-24X
STC 24 4-80X
STC 24 5-60X
STC 24 6-40X
STC 25 8-05X
STC 25 10-05X
STC 30 8-86X
STC 30 10-86X
STC 35 9-67X
STC 35 11-67X
STC 35 6-40X
STC 35 7-25X
STC 36-8X
STC 40 12-48X
STC 45 13-29X
STC 46-8X
STC 47 9-25X

208

Nom.
mount.
ht. (ft.)

Pole
Shaft Size
(in. x in. x ft.)

80
mph

Max
wt.

90
mph

Max
wt.

100
mph

Max.
wt.

Approx.
ship wt.
(lbs.)

10
16
16
20
20
20
20
20
25
25
29
29
30
30
30
34
38
40
40

4.0 x 4.0 x 13
4.0 x 7.24 x 20
6.0 x 9.24 x 20
4.8 x 4.8 x 24
5.6 x 5.6 x 24
6.4 x 6.4 x 24
4.0 x 8.05 x 25
6.0 x 10.05 x 25
4.0 x 8.86 x 30
6.0 x 10.86 x 30
4.0 x 9.67 x 35
6.0 x 11.67 x 35
6.4 x 6.4 x 35
7.25 x 7.25 x 35
8.0 x 8.00 x 36
6.0 x 12.48 x 40
6.0 x 13.29 x 45
8.0 x 8.0 x 46
9.25 x 9.25 x 47

3.5
22
48
3.5
3.5
3.5
21
44
20
49
17
43
3.5
3.5
3.2
42
41
3.5
3.5

100
550
1,220
510
510
510
510
1,050
460
1,090
400
1,010
400
1,010
920
820
820
820
820

3.5
16
37
N/A
3.5
3.5
16
34
15
33
12
32
N/A
3.5
3.5
30
31
N/A
3.5

430
430
950
N/A
390
390
390
810
340
830
290
760
N/A
760
670
590
590
N/A
000

3.5
13
29
N/A
N/A
3.5
12
26
11
28
8
24
N/A
N/A
3.5
22
21
N/A
N/A

330
330
760
N/A
N/A
300
300
640
250
650
200
580
N/A
N/A
500
420
420
N/A
N/A

189
680
1,110
517
686
917
985
1,530
1,350
2,000
1,800
2,540
1,337
1,685
2,145
3,130
3,795
2,740
3,813

Product Guide

If poles are stored outside, all protective wrapping must be


removed immediately to prevent finish damage.

For more information please visit our website:


www.americanelectriclighting.com

SPRTC
Direct Burial Poles
Round Tapered Concrete Sportslighting

P R O D U C T

O V E R V I E W

Intended Use
For 45 to 115 mounting height.

Features
Shaft Concrete mix has a minimum 28-day compressive strength of
11,000 PSI and conforms with ASTM-C150. Prestressing steel
reinforcement is uncoated 7 wire, stress relieved strand per ASTMA416. Steel spiral reinforcement conforms to ASTM-A82 and is not
less than .203 (5-gauge wire) diameter. Poles have a continuous taper
of 0.216 inches per foot. Poles are centrifugally spun and round in
cross-section with a hollow center.
Handhole 4"x8" handhole is located 24" above ground line. 4"x8"
conduit entrance is located 18" below ground line. 2 1/2"x8" reinforced

handhole with flush cover is located at cage/crossarm locations. 11/2" coupling wire inlet/outlet is located opposite this handhole.
Inserts for handhole and conduit entrance are non-corrosive and
weatherproof. Handhole frames and covers conform to ASTM-B240.
Grounding A continuous solid or stranded copper ground wire is
cast into the pole. Wire terminates at top of pole to accept a 1/2"x24"
lightning rod. Copper coupling, approximately 12 below grade,
provides a 1/2" tapped insert at pole face for grounding hardware.
Hardware Fasteners are high-strength galvanized or stainless steel.
Finish Smooth, natural form finish, soft gray color is standard.

Ordering Information: See page 191 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:

Technical Information

Do not erect poles without having fixtures installed.


If poles are stored outside, all protective wrapping must be
removed immediately to prevent finish damage.

EPA (ft2) with 1.3 gust


Catalog
Number
SPRTC C6 45 7-17
SPRTC C5 45 7-17
SPRTC C4 45 7-17
SPRTC C4 60 7-20
SPRTC C2 60 9-22
SPRTC H1 60 9-22
SPRTC C3 70 9-24
SPRTC C1 70 9-24
SPRTC H2 70 10-24
SPRTC C2 80 9-26
SPRTC C1 80 9-26
SPRTC H2 80 10-26
SPRTC C2 90 9-28
SPRTC C1 90 9-28
SPRTC H2 90 10-28
SPRTC C1 105 9-32
SPRTC H1 105 9-32
SPRTC H3 105 11-34
SPRTC C1 115 9-34
SPRTC H1 115 9-34
SPRTC H2 115 10-34

Nom.
mount.
ht. (ft.)

Pole
Shaft Size
(in. x in. x ft.)

80
mph

Max
wt.

90
mph

Max
wt.

100
mph

38
38
38
50
50
50
60
60
60
68
68
68
77
77
77
91
91
91
100
100
100

6.75 X 16.47 X 45
6.75 X 16.47 X 45
6.75 X 16.47 X 45
6.75 X 19.71 X 60
8.82 X 21.78 X 60
8.82 X 21.78 X 60
8.82 X 23.94 X 70
8.82 X 23.94 X 70
8.82 X 23.94 X 70
8.82 X 26.1 X 80
8.82 X 26.1 X 80
8.82 X 26.1 X 80
8.82 X 28.26 X 90
8.82 X 28.26 X 90
8.82 X 28.26 X 90
8.82 X 31.5 X 105
8.82 X 31.5 X 105
11.0 X 33.68 X 105
8.82 X 33.66 X 115
8.82 X 33.66 X 115
8.82 X 33.66 X 115

31
39
52
47
85
138
56
90
139
63
85
136
54
78
132
70
99
144
65
96
125

620
780
1,040
893
1,615
2,622
1,064
1,710
2,641
1,197
1,445
2,584
1,026
1,482
2,508
1,330
1,881
2,736
1,235
1,824
2,375

24
30
40
35
65
101
42
69
103
45
65
101
39
56
97
49
74
105
45
70
91

480
600
800
665
1,235
1,919
798
1,311
1,957
855
1,105
1,919
741
1,064
1,843
931
1,406
1,995
855
1,330
1,729

18
23
31
26
48
80
32
52
81
34
48
79
28
42
75
35
54
80
31
50
69

Approx.
Max. Ship wt.
wt.
(lbs.)
360
460
589
520
912
1,520
608
988
1,539
646
816
1,501
532
798
1,425
665
1,026
1,520
589
950
1,311

3,400
3,400
3,450
5,450
7,950
8,100
9,900
10,100
10,400
12,300
12,300
12,800
14,850
14,950
15,350
19,250
19,450
22,050
22,350
22,550
22,800

Product Guide

209

SPRTC
Crossarm Options
For Round Tapered Concrete and Wood Sportslighting Poles

P R O D U C T

O V E R V I E W

Angle Iron Crossarms for Concrete Poles


Projected area is for the crossarm only. The crossarm projected area is added
to the luminaire projected area to get a total effective projected area (EPA).

ACRCW4
4-Fixture Angle Arm

ACRCW3
3-Fixture Angle Arm

6'- 0"

1'- 9"

ACRCW2
2-Fixture Angle Arm

Notes:
1 Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88 diameter.

210

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

SPRTC
Crossarm Options
For Round Tapered Concrete and Wood Sportslighting Poles

P R O D U C T

O V E R V I E W

Angle Iron Crossarms for Concrete or Wood Poles


Projected area is for the crossarm only. The crossarm projected area is added
to the luminaire projected area to get a total effective projected area (EPA).

ACRCW6
6-Fixture Angle Arm

ACRCW5
5-Fixture Angle Arm

Angle Iron Crossarms


For Concrete Poles
Catalog
Number

Arm EPA
(sq. ft.)

Weight
(lbs.)

ACRCW2
ACRCW3
ACRCW4
ACRCW5
ACRCW6

1.80
3.00
4.50
5.70
7.00

50.0
86.0
121.0
157.0
193.0

Notes:
1 Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88 diameter.

Product Guide

211

SPRTC
Crossarm Options
For Round Tapered Concrete and Wood Sportslighting Poles

P R O D U C T

O V E R V I E W

Pre-wired Tubular Crossarms for Concrete or Wood Poles

Pre-wired Tubular
Crossarms
For Concrete Poles

Projected area is for the crossarm only. The crossarm projected area is added to
the luminaire projected area to get a total effective projected area (EPA).

SPXCW6

Catalog
Number

EPA
(sq. ft.)

Weight
(lbs.)

SPXCW2
SPXCW3
SPXCW4
SPXCW5
SPXCW6

1.00
1.80
2.50
3.20
3.90

23.5
40.0
56.5
73.0
89.5

6-Fixture Crossarm

SPXCW5
5-Fixture Crossarm

SPXCW4

SPXCW2

4-Fixture Crossarm

2-Fixture Crossarm

6.50

SPXCW3
3-Fixture Crossarm

Notes:
1 Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88 diameter.

212

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

SPRTS
Anchored Base Poles
Round Tapered Steel

P R O D U C T

Intended Use

O V E R V I E W

For 40 to 80 mounting height.

Handhole An oval, reinforced handhole rim having a nominal


dimension of 4"x6.5". Steel cover with attachment screws included.
Handhole is located 18" above base.

Features

Grounding Nut holder located immediately inside handhole rim is


provided with 1/2" 13 UNC ground bolt and nut.

Shaft The cross section shall be round or 16-sided with a 4" bend
radius. Each pole is a constant tapered hollow steel section and shall
be up to 55 feet in length with a minimum 1 1/2 times diameter slip
joint as standard. The pole shaft sections shall be high strength low
alloy steel conforming to ASTM A572 Grade 65 or ASTM A595 Grade
A. The plate shall be single thickness no laminations.

Anchor Bolts Fabricated from commercial-quality hot-rolled carbon


steel with minimum-yield strength of 55,000 PSI. Bolts have an "L"
bend on one end.
Hardware Fasteners are high-strength galvanized or zinc-plated or
stainless steel.
Top Cap Weather-proof removable top cap provided with all drillmount poles.

Anchor Base Fabricated from hot-rolled carbon steel plate that


conforms to ASTM A36 or ASTM A572 Grade 42.
Ordering Information: See page 191 (Note: Poles are available only in U.S.)

Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
SPRTS 40 HT01
SPRTS 40 HT02
SPRTS 40 HT03
SPRTS 50 HT01
SPRTS 50 HT02
SPRTS 50 HT03
SPRTS 50 HT04
SPRTS 50 HT05
SPRTS 60 HT01
SPRTS 60 HT02
SPRTS 60 HT03
SPRTS 60 HT04
SPRTS 70 HT01
SPRTS 70 HT02
SPRTS 70 HT03
SPRTS 70 HT04
SPRTS 70 HT05
SPRTS 80 HT01
SPRTS 80 HT02
SPRTS 80 HT03
SPRTS 80 HT04

Nom. Base
mount. Dia.
ht (ft.) (in.)
40
40
40
50
50
50
50
50
60
60
60
60
70
70
70
70
70
80
80
80
80

5
6.5
6.6
12
6.6
6.6
12
12
12
12
12
13
12

Wall
Thick.
(in.)

Base
Dia.
(in.)

Wall
Thick.
(in.)

80
mph

Max.
wt.

90
mph

Max.
wt.

100
mph

Max.
wt.

Bolt
Bolt
Num. of
Circle
Size
Anchor
(in.) (in. x in. x in.) Bolts

0.1196
0.1196
0.1793
0.1793
0.1793
0.1793
0.1793
0.1793
0.1793
0.1793
0.1793
0.1875
0.1793

9
9
10
10
10
11
13
13
11.5
13
13
15.87
13
13
14.57
15.87
16.82
15.87
16.82
17.53
18.7

0.1193
0.1793
0.1793
0.1193
0.1793
0.1793
0.1793
0.2391
0.1793
0.1793
0.2391
0.1875
0.1793
0.2391
0.1875
0.1875
0.1875
0.1875
0.1875
0.2092
0.1875

17.2
26.1
38.6
13.2
20.5
29.9
50.4
69.2
20.0
36.0
49.0
78.0
20.6
23.8
39.0
52.0
65.0
37.0
45.0
58.0
70.0

430
654
965
330
512
748
1,260
1,730
600
1,080
1,470
2,340
515
595
1,170
1,560
1,950
1,110
1,350
1,740
2,100

13.5
20.6
30.6
10.6
16.5
23.5
39.7
55.0
16.0
29.0
40.0
62.0
16.7
19.3
30.0
41.0
53.0
29.0
36.0
46.0
56.0

338
517
765
265
412
588
992
1,375
480
870
1,200
1,860
417
482
900
1,230
1,590
870
1,080
1,380
1,680

10.8
16.7
24.6
8.3
13.6
18.6
31.4
44.2
13.0
22.0
32.0
50.0
13.7
15.9
23.0
33.0
42.0
23.0
28.0
35.0
44.0

270
419
615
208
340
465
785
1,105
390
660
960
1,500
342
397
690
990
1,260
690
840
1,050
1,320

12.5
12.5
13.5
13.5
13.5
15
17
17.5
16
17
17
21
17
17.5
19
21
22.75
21
22.75
23
23

1 x 36 x 4
1.25 x 42 x 6
1.25 x 42 x 6
1 x 36 x 4
1.25 x 42 x 6
1.25 x 42 x 6
1.50 x 54 x 6
1.75 x 84 x 6
1.25 x 42 x 6
1.25 x 42 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.75 x 84 x 6
1.25 x 42 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6

4
4
4
4
4
4
4
4
4
6
6
6
4
4
6
6
6
6
6
6
8

INSTALLATION NOTES:
Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage.

4-Bolt

6-Bolt

8-Bolt

Handhole

Handhole

Handhole

Product Guide

213

SPRTS
Crossarm Options
For Round Tapered Steel Sportslighting Poles

P R O D U C T

O V E R V I E W

Angle Iron Crossarms for Steel Poles


Pre-wired Tubular
Crossarms
For Steel Poles

Projected area is for the crossarm only. The crossarm projected area
is added to the luminaire projected area to get a total effective
projected area (EPA).

ACR6
6-Fixture Angle Arm

214

ACR5

ACR4

5-Fixture Angle Arm

4-Fixture Angle Arm

ACR3

ACR2

3-Fixture Angle Arm

2-Fixture Angle Arm

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

Catalog
Number

Arm EPA
(sq. ft.)

Weight
(lbs.)

ACR2
ACR3
ACR4
ACR5
ACR6

1.74
2.73
3.97
5.95
7.37

30.0
47.0
68.0
103.0
127.0

SPRTS
Crossarm Options
For Round Tapered Steel Sportslighting Poles

P R O D U C T

Tubular Crossarms for Steel Poles

O V E R V I E W

Tubular Crossarms
For Steel Poles

Projected area is for the crossarm only. The crossarm projected area
is added to the luminaire projected area to get a total effective
projected area (EPA).

CR8
8-Fixture Crossarm

CR7

CR6

7-Fixture Crossarm

6-Fixture Crossarm

CR5

CR4

5-Fixture Crossarm

4-Fixture Crossarm

CR3

CR2

3-Fixture Crossarm

2-Fixture Crossarm

Catalog
Number

EPA
(sq. ft.)

Weight
(lbs.)

CR2
CR3
CR4
CR5
CR6
CR7
CR8

1.28
2.45
3.21
4.17
5.13
6.10
7.06

44.0
65.0
98.0
116.0
150.0
176.0
271.0

Product Guide

215

RTAU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Mounting Arm

P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

Intended Use
20 to 40 fixture mounting.

Pole Grounding System A ground lug located immediately inside


the handhole is tapped for 3/8"-16 UNC ground bolt (provided by
others).

Features

Pole Installation Anchor bolts Top portion of anchor bolt is


galvanized per ASTM A-153. Made of steel rod having a minimum
yield strength of 55,000 psi.

Pole Construction Spun-tapered seamless 6063 alloy aluminum


tubing, heat-treated to produce a T6 temper. Circumferential satinbrushed finish. The shaft is cone-tapered to the butt diameter.
3 sections cast from A356 alloy aluminum, the anchor base is heattreated to a T6 condition. The anchor base telescopes the pole shaft
and is circumferentially welded at both the top and the bottom.

Mounting Arm Construction Body of the mounting arm is tapered


aluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at the
luminaire end. The pole end of the arm is welded to an aluminum alloy
6063-T6 mounting plate.

A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole is


centered 18" above the base.

Welding follows AWS and CSA standards. Arms are chemically


cleaned after fabrication.

Removable cast aluminum top cap provided.

Mounting The mounting plate is designed to be bolted to the shaft


using four 1/2" stainless steel bolts, nuts and washers. A grommet is
provided for the 1-1/4" diameter wiring hole between the pole shaft
and the bracket arm.

All screws, nuts and bolts are made of stainless steel.


A356 nut covers are included with each anchor base unless
otherwise specified.

Mounting Arm Finish Satin aluminum is standard. Optional


polyester powder paint and anodized finishes available.

Pole Finish Brushed aluminum (BA) is standard. Optional polyester


powder paint and anodized finishes available.

Example: R T A U 2 0 6 G B M A U S 8 V D B A A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, please add AEL after the last option
RTAU
Shaft/arm type

Fixture Mounting
Height

RTAU
20 - 40 feet
(See Chart Opposite)

Nominal Shaft
Base Size/
Wall Thickness

Options

Mounting
BMA

(See Chart
Opposite)

Bolt-on
Mast Arm

Arm Length4
Notes:
1 Specify location and orientation when
ordering option.
For 1st "x": Specify the height in feet
above base of pole.
Use two digits to specify height:
Example: 5ft = 05 and 20ft = 20
For 2nd "x": Specify orientation from
handhole (A,B,C,D)
Refer to the Handhole Orientation
diagram on this page.
2 Horizontal arm is 18" x 2-3/8" O.D.
tenon standard.
3 Other colors available, please contact
local AEL representative.
4 Some restrictions apply, see back
page for details.

US4
US6
US8

4' Arm Length


6' Arm Length
8' Arm Length

Shipped Installed
L/AB Less Anchor Bolts
FBC Full Base Cover
VD Vibration Damper
TP Tamper Proof
HAAxx1,2 Horizontal Arm
Bracket (1 fixture)
FDLxx1 Festoon Outlet Less
Electrical
12CPxx1 1/2" Coupling
34CPxx1 3/4" Coupling
1CPxx1 1" Coupling
12NPxx1 1/2" Threaded Nipple
34NPxx1 3/4" Threaded Nipple
1NPxx1 1" Threaded Nipple
HHxx1 Extra Handhole

Arm located
on side B

Handhole
216

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

Architectural Colors
(powder finish)3
Standard Colors
BA Brushed
Aluminum (std)
DDB Dark Bronze
DWH White
DBL Black
Class 1 Arch. Anodize
ABL Black
ADB Dark Bronze
ANA Natural

RTAU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Twin Mounting Arms

P R O D U C T

O V E R V I E W

Intended Use

O R D E R I N G

I N F O R M AT I O N

20 to 40 fixture mounting.

Pole Grounding System A ground lug located immediately inside


the handhole is tapped for 3/8"-16 UNC ground bolt (not supplied).

Features

Pole Installation Anchor bolts Top portion of anchor bolt is


galvanized per ASTM A-153. Made of steel rod having a minimum
yield strength of 55,000 psi.

Pole Construction Spun-tapered seamless 6063 alloy aluminum


tubing, heat-treated to produce a T6 temper. Circumferential satinbrushed finish. The shaft is cone-tapered to the butt diameter.

Mounting Arm Construction Body of the mounting arm is tapered


aluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at the
luminaire end. The pole end of the arm is welded to an aluminum alloy
6063-T6 mounting plate.Welding follows AWS and CSA standards.
Arms are chemically cleaned after fabrication.

Cast from A356 alloy aluminum, the anchor base is heat-treated to a


T6 condition. The anchor base telescopes the pole shaft and is
circumferentially welded at both the top and the bottom.

Mounting The mounting plate is designed to be bolted to the shaft


using four 1/2" stainless steel bolts, nuts and washers. A grommet is
provided for the 1-1/4" diameter wiring hole between the pole shaft
and the bracket arm.

A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole is


centered 18" above the base.
Cast aluminum cap provided.

Mounting Arm Finish Satin aluminum is standard. Optional


polyester powder paint and anodized finishes available.

All screws, nuts and bolts are made of stainless steel.


A356 nut covers are included with each anchor base unless
otherwise specified.
Pole Finish Brushed aluminum (BA) is standard. Optional polyester
powder paint and anodized finishes available.

Example: R T A U 2 0 6 G B M A 2 U S 4 B A V D A E L

Ordering Information:

Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option

RTAU
Shaft/Arm Type

Fixture Mounting
Height

RTAU
20 - 40 feet
(See Chart Opposite)

Nominal Shaft
Base Size/
Wall Thickness

Options

Mounting
BMA

Bolt-on
Mast Arm

(See Chart
Opposite)

Arm Length4
Notes:
1 Specify location and orientation when
ordering option.
For 1st "x": Specify the height in feet
above base of pole.
Use two digits to specify height:
Example: 5ft = 05 and 20ft = 20
For 2nd "x": Specify orientation from
handhole (A,B,C,D)
Refer to the Handhole Orientation
diagram on this page.
2 Horizontal arm is 18" x 2-3/8" O.D.
tenon standard.
3 Other colors available, please contact
your local American Electric Lighting
representative.
4 Some restrictions apply, see chart for
details.

2US4
2US6
2US8

4' Arm Length


6' Arm Length
8' Arm Length

Shipped Installed
L/AB Less Anchor Bolts
FBC Full Base Cover
VD Vibration Damper
TP Tamper Proof
HAAxx1,2 Horizontal Arm
Bracket (1 fixture)
FDLxx1 Festoon Outlet Less
Electrical
12CPxx1 1/2" Coupling
34CPxx1 3/4" Coupling
1CPxx1 1" Coupling
12NPxx1 1/2" Threaded Nipple
34NPxx1 3/4" Threaded Nipple
1NPxx1 1" Threaded Nipple
HHxx1 Extra Handhole

Architectural Colors
(Powder Finish)3
Standard Colors
BA Brushed
Aluminum (std)
DDB Dark Bronze
DWH White
DBL Black
Class 1 Arch. Anodize
ABL Black
ADB Dark Bronze
ANA Natural

Arms
located on
sides B & D

Handhole

Product Guide

217

RTAU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Twin Mounting Arms

P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

Technical Information
EPA (ft2) with 1.3 gust

218

AEL Catalog Number

Fixture Mtg.
Height1
(feet)

Mtg. Arm
length
(feet)

Pole Shaft
Diam.
(in. x in.)

RTAU 20 6G BMA 2US4


RTAU 20 6G BMA 2US6
RTAU 20 6E BMA 2US8
RTAU 20 6E BMA 2US4
RTAU 20 6E BMA 2US6
RTAU 20 6E BMA 2US8
RTAU 25 6G BMA 2US4
RTAU 25 6E BMA 2US6
RTAU 25 7E BMA 2US6
RTAU 25 7E BMA 2US4
RTAU 25 7E BMA 2US6
RTAU 25 7E BMA 2US8
RTAU 30 8G BMA 2US4
RTAU 30 8G BMA 2US6
RTAU 30 8G BMA 2US8
RTAU 30 8E BMA 2US4
RTAU 30 8E BMA 2US6
RTAU 30 8E BMA 2US8
RTAU 30 7E BMA 2US4
RTAU 30 7E BMA 2US6
RTAU 30 7E BMA 2US8
RTAU 35 8G BMA 2US4
RTAU 35 8G BMA 2US6
RTAU 35 8J BMA 2US4
RTAU 35 8J BMA 2US6
RTAU 35 8J BMA 2US8
RTAU 35 8E BMA 2US6
RTAU 35 8E BMA 2US8
RTAU 40 8G BMA 2US8
RTAU 40 8L BMA 2US6
RTAU 40 8J BMA 2US6
RTAU 40 8J BMA 2US8
RTAU 40 8J BMA 2US4

20'
20'
20'
20'
20'
20'
25'
25'
25'
25'
25'
25'
30'
30'
30'
30'
30'
30'
30'
30'
30'
35'
35'
35'
35'
35'
35'
35'
40'
40'
40'
40'
40'

4'
6'
8'
4'
6'
8'
4'
6'
6'
4'
6'
8'
4'
6'
8'
4'
6'
8'
4'
6'
8'
4'
6'
4'
6'
8'
6'
8'
8'
6'
6'
8'
4'

4" x 6"
4" x 6"
4" x 6"
4" x 6"
4" x 6"
4" x 6"
4" x 6"
4" x 7"
4" x 7"
4" x 7"
4" x 7"
4" x 7"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 7"
4.5" x 7"
4.5" x 7"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"
4.5" x 8"

Product Guide

Wall
thickness
(in.)
0.188
0.188
0.188
0.156
0.156
0.156
0.188
0.156
0.188
0.156
0.156
0.156
0.188
0.188
0.188
0.156
0.156
0.156
0.156
0.156
0.156
0.188
0.188
0.250
0.250
0.250
0.156
0.156
0.188
0.219
0.250
0.250
0.250

(Max per arm)


EPA ft2 with 1.3 gust
80 mph
90 mph
100 mph
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2
2
2
2
1.9
0.8
1.3
1.8
2
2
1.8
0.7
2
2
2
2
1.8
0.8
2
1.8
2
1.8
1.3
2
2
2
1.3
2
2
2
1.9
0.9
2

2
1.9
0.8
1.5
0.9
n/a
0.6
0.8
1.5
1.3
0.8
n/a
2
1.9
0.9
1.3
0.8
n/a
1.3
0.8
0.9
0.8
n/a
2
2
1.1
n/a
1.1
1.3
2
0.8
n/a
1.4

For more information please visit our website:


www.americanelectriclighting.com

Max. Weight
per arm
(lbs.)

Bolt
Circle
(in.)

Bolt Size
(inches)

App. Ship
Weight
(pounds)

80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

9-10
9-10
9-10
9-10
9-10
9-10
9-10
9-10
10-11
10-11
10-11
10-11
11-12
11-12
11-12
11-12
11-12
11-12
10-11
10-11
10-11
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12

3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 42
1 x 36 x 42
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4

107
110
112
94
97
99
117
120
135
144
147
134
183
186
188
160
163
165
156
159
161
14
17
263
266
268
190
192
241
271
301
303
298

RTAU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Twin Mounting Arms

P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

1. Denotes fixture mounting heights, NOT nominal pole height.


Shaft
Base
Size

Bolt
Circle
A

Bolt
Projection
B

6"
7"
8"

9"10"
10"11"
11"12"

3-1/2"
4-1/8"
4-1/4"

Base Warehouse
Square Anchor Bolt
C
Description

Template
Number

10"
10-1/2"
11-1/2"

PJ50033
PJ50034
PJ50035

AB30-0
AB36-0
AB36-0

IMPORTANT:
Do not erect poles without having fixtures installed.
Factory-supplied templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorage
placement due to failure to use factory template.
If poles are stored outside, all protective wrapping must be removed
immediately to prevent finish damage.
Installation requires grout be packed under base to ensure full contact with
foundation.

Peripherally
reinforced
handhole door

Cast aluminum
nut cover
Grout

18

IMPORTANT:
These specifications are intended for general purposes only. American
Electric Lighting reserves the right to change material or design, without
prior notice, in a continuing effort to upgrade its products.

Product Guide

219

RTSU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Steel Pole with Single Mounting Arm

P R O D U C T

O V E R V I E W

O R D E R I N G

Intended Use

I N F O R M AT I O N

Pole Finish Galvanized Steel (GALV) is standard. Optional polyester


powder paint finishes available.

20 to 40 fixture mounting.

Pole Grounding System A ground lug is located immediately inside


the handhole rim.

Features
Pole Construction Weldable-grade hot-rolled, commercial-quality
carbon steel tubing with a minimum yield of 55,000 psi. Uniform wall
thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are onepiece construction with a full-length longitudinal high-frequency
resistance weld. Round in cross-section having a uniform taper of
approximately .14" per foot.
Anchor base is fabricated from hot-rolled carbon steel plate that
conforms to ASTM A36.
A reinforced handhole having nominal dimensions of 3" x 5" for shafts
less than 6.25" base diameter and 4" x 6.5" for all other shafts. Cover
with attachment screws included. Handhole is located 18" above the
base.

Pole Installation Anchor bolts Fabricated from commercialquality, hot-rolled carbon steel with minimum yield strength of 55,000
psi. Bolts have an "L" bend on one end.
Mounting Arm Construction Body is 2-3/8" O.D. (2" NPS) galvanized
steel tube (sch. 40 material, min. yield strength 36,000 psi).
Welding follows AWS standards. Arms are galvanized after fabrication.
Mounting Arm Hardware Mounting plate is designed to be bolted to
the shaft using a 1/2" steel bolt Simplex mount. Single-bolt (US4, US6,
US8) or multi-bolt design (US10, US12).
Mounting Arm Finish Galvanized Steel (GALV) is standard. Optional
polyester powder paint finishes available.

Weatherproof, removable top cap provided.


Fasteners are high-strength galvanized zinc-plated or stainless steel.

Example: R T S U 2 5 S M P U S 4 G A L V V D A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
RTSU
Shaft/arm type

Fixture mounting
height

Nominal Shaft
base size/
wall thickness

20 - 40 feet
(See Chart
Opposite)

(See Chart
Opposite)

RTSU

Notes:
1 Specify location and orientation when
ordering option.
For 1st "x": Specify the height in feet
above base of pole.
Use two digits to specify height:
Example: 5ft = 05 and 20ft = 20
For 2nd "x": Specify orientation from
handhole (A,B,C,D)
Refer to the Handhole Orientation
diagram on this page.
2 Horizontal arm is 18" x 2-3/8" O.D.
tenon standard.
3 Other colors available, please contact
your local American Electric Lighting
representative.
4 Some restrictions may apply, see
chart for details.

220

Product Guide

Options

Mounting / Arm Length4


SMP US4

Single-bolt
Simplex Mount, 4'
Arm Length
SMP US6 Single-bolt
Simplex Mount, 6'
Arm Length
SMP US8 Single-bolt
Simplex Mount, 8'
Arm Length
MSMP US10 Multi-bolt
Simplex Mount ,
10' Arm Length
MSMP US12 Multi-bolt
Simplex Mount ,
12' Arm Length

Shipped Installed
L/AB Less Anchor Bolts
FBC Full Base Cover
VD Vibration Damper
TP Tamper Proof
HASxx1,2 Horizontal Arm
Bracket (1 fixture)
FDLxx1 Festoon Outlet Less
Electrical
12CPxx1 1/2" Coupling
34CPxx1 3/4" Coupling
1CPxx1 1" Coupling
12NPxx1 1/2" Threaded Nipple
34NPxx1 3/4" Threaded Nipple
1NPxx1 1" Threaded Nipple
HHxx1 Extra Handhole

For more information please visit our website:


www.americanelectriclighting.com

Architectural Colors
(powder finish)3
Standard Colors
GALV Galvanized
Finish (std)
DDB Dark Bronze
DWH White
DBL Black

RTSU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Steel Pole with Single Mounting Arm

P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

Technical Information
EPA (ft2) with 1.3 gust
Fixture Mtg.
Height1
(feet)

AEL Catalog Number

RTSU 20 5-9B SMP US4


RTSU 20 5-9B SMP US6
RTSU 20 5-9B SMP US8
RTSU 25 5-9B SMP US4
RTSU 25 5-9B SMP US6
RTSU 25 5-9B SMP US8
RTSU 20 6-5B SMP US4
RTSU 20 6-5B SMP US6
RTSU 20 6-5B SMP US8
RTSU 25 7B SMP US4
RTSU 25 7B SMP US6
RTSU 25 7B SMP US8
RTSU 25 7B MSMP US10
RTSU 25 7B MSMP US12
RTSU 30 8B SMP US4
RTSU 30 8B SMP US6
RTSU 30 8B SMP US8
RTSU 30 8B MSMP US10
RTSU 30 8B MSMP US12
RTSU 35 8-5B SMP US4
RTSU 35 8-5B SMP US6
RTSU 35 8-5B SMP US8
RTSU 35 8-5B MSMP US10
RTSU 35 8-5B MSMP US12
RTSU 40 9B SMP US4
RTSU 40 9B SMP US6
RTSU 40 9B SMP US8
RTSU 40 9F MSMP US10
RTSU 40 9F MSMP US12

20'
20'
20'
25'
25'
25'
20'
20'
20'
25'
25'
25'
25'
25'
30'
30'
30'
30'
30'
35'
35'
35'
35'
35'
40'
40'
40'
40'
40'

Mtg. Arm
length
(feet)

Pole Base
Diameter
(.14 taper rate)

Wall
thickness
(in.)

4'
6'
8'
4'
6'
8'
4'
6'
8'
4'
6'
8'
10'
12'
4'
6'
8'
10'
12'
4'
6'
8'
10'
12'
4'
6'
8'
10'
12'

5.9"
5.9"
5.9"
5.9"
5.9"
5.9"
6.5"
6.5"
6.5"
6.8"
6.8"
6.8"
6.8"
6.8"
8"
8"
8"
8"
8"
8.5"
8.5"
8.5"
8.5"
8.5"
9"
9"
9"
9"
9"

0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.180
0.180

(Max per arm)


Max Weight
EPA ft2 w/ 1.3 gust up to
per arm
100 mph
(lbs)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76

Bolt
Circle
(in.)

Bolt Size
(inches)

9
9
9
9
9
9
9.5
9.5
9.5
10.5
10.5
10.5
10.5
10.5
11
11
11
11
11
11.5
11.5
11.5
11.5
11.5
12.5
12.5
12.5
12.5
12.5

1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1.25 x 42 x 6
1.25 x 42 x 6

1. Denotes fixture mounting heights, NOT nominal pole height.

Shaft
Base
Size

Bolt 1
Circle
A

Bolt
Projection
B

Base
Square
C

Warehouse
Anchor Bolt
Description

Template
Number

5.9" B
6.5" B
7.0" B
8.0" B
8.5" B
9.0" B
9.0" F

9"
9.5"
10"
11"
11.5"
12.5"
12.5"

3-1/2"4-1/4"
3-1/2"4-1/4"
3-1/2"4-1/4"
3-1/2"4-1/4"
3-3/4"4-1/2"
3-3/4"4-1/2"
4-1/2"5-1/4"

10"
10-1/2"
10-7/8"
11-1/2"
12"
12-3/8"
12-3/8"

AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AAB36-0
N/A

PJ50075
PJ50074
PJ50077
PJ50079
PJ50082
PJ50085
PJ50086

IMPORTANT:
Do not erect poles without having fixtures installed.
Factory-supplied templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorage
placement due to failure to use factory template.
If poles are stored outside, all protective wrapping must be removed
immediately to prevent finish damage.
Installation requires grout be packed under base to ensure full contact
with foundation.

IMPORTANT:
These specifications are intended for general purposes only. American Electric
Lighting reserves the right to change material or design, without prior notice, in a
continuing effort to upgrade its products.

Product Guide

221

AMAW / SMAW
AMAW: Aluminum Mounting Arm, Wood Poles
SMAW: Steel Mounting Arm, Wood Poles
P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

Steel Body is galvanized steel tube (per ASTM A-123) constructed


from A500 Grade B steel. Base is 3/16" plate.

Intended Use
Mounting roadway fixtures to wood poles.

Welding follows AWS standards. Arms are galvanized after


fabrication.

Features

Finish Satin aluminum or galvanized steel is standard. Optional


polyester powder finishes available.

Construction
Aluminum Body is schedule 10 (T14) or schedule 40 (T20)
aluminum pipe 6005-T5. Base is 3/8" aluminum plate.

Hardware not included

Welding follows AWS standard. Arms are pressure-washed after


fabrication.

Example: A M A W T 2 0 U S 4 S A A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option

Pipe Size

Series
AMAW
SMAW

T14
T20

Arm Length (feet)

1 - 2/3 O.D. (1 - 1/4 NPS)


2 - 3/8 O.D. (2 NPS)

US2-5
US4
US6
US8

2-1/2' Arm Length


4' Arm Length
6' Arm length2
8' Arm Length2

Notes:
1 Other colors available, please contact
your local American Electric Lighting
representative.
2 Not available with AMAWT14.

222

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

Options
Standard Finish
SA Satin Aluminum
(standard w/ AMAW)
GALV Galvanized Steel (standard w/ SMAW)
Architectural Colors (powder finish)1
Standard Colors
DDB Dark Bronze
DWH White
DBL Black

AMAW / SMAW
AMAW: Aluminum Mounting Arm, Wood Poles
SMAW: Steel Mounting Arm, Wood Poles
P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

AMAW / SMAW
AEL Catalog Number

Nominal
Arm Length
(feet)

Dimensions
(inches)
A

Weight
(pounds)

(Max per arm)


EPA ft2 w/ 1.3 gust
up to 100mph

Max Weight
per arm
(lbs)

AMAW T14 US2-5


AMAW T14 US4
AMAW T14 US6
AMAW T20 US2-5
AMAW T20 US4
AMAW T20 US6
AMAW T20 US8

2'6"
4'
6'
2'6"
4'
6'
8'

30"
42"
66"
30"
42"
66"
90"

15"
19"
24"
15"
10"
24"
30"

10"
10"
12"
10"
10"
12"
15"

3
4
6
6
7
10
12

2
2
2
2
2
2
2

76
76
76
76
76
76
76

SMAW T14 US2-5


SMAW T14 US4
SMAW T14 US6
SMAW T14 US8
SMAW T20 US2-5
SMAW T20 US4
SMAW T20 US6
SMAW T20 US8

2'6"
4'
6'
8'
2'6"
4'
6'
8'

30"
42"
66"
90"
30"
42"
66"
90"

15"
19"
24"
30"
15"
19"
24"
30"

10"
10"
12"
15"
10"
10"
12"
15"

9
11
15
20
15
18
24
30

2
2
2
2
2
2
2
2

76
76
76
76
76
76
76
76

IMPORTANT:

CAUTION:

These specifications are intended for general purposes only. American


Electric Lighting reserves the right to change material or design, without
prior notice, in a continuing effort to upgrade its products.

The arms described herein are designed for applications in areas of normal
winds. Consult the factory prior to the design of systems to be mounted on
structures such as bridges or buildings, or areas known to have abnormal
winds such as airports or coastal areas. Failure to consider these factors
in the system design could result in the failure of the pole or mast arm, and
consequently personal injury or property damage.

.562" Dia.

Product Guide

223

AMAC / SMAC
AMAC: Aluminum Mounting Arm, Concrete Poles
SMAC: Steel Mounting Arm, Concrete Poles
P R O D U C T

O V E R V I E W

O R D E R I N G

Intended Use

I N F O R M AT I O N

Steel Body is galvanized steel tube (per ASTM A-123) constructed


from A500 Grade B steel. Base is 3/16" plate.

Mounting roadway fixtures to concrete poles.

Welding follows AWS standards. Arms are galvanized after


fabrication.

Features
Construction

Finish Satin aluminum or galvanized steel is standard. Optional


polyester powder paint finishes available.

Aluminum Body is schedule 10 (T14) or schedule 40 (T20) aluminum


pipe 6005-T5. Base is 3/8" aluminum plate.

Hardware not included

Welding follows AWS standard. Arms are pressure-washed after


fabrication.

Example: A M A C T 2 0 U S 4 S A A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option

Pipe Size

Series
AMAC
SMAC

T14
T20

1 - 2/3 O.D. (1 - 1/4 NPS)


2 - 3/8 O.D. (2 NPS)

US4
US6
US8

Arm Length (feet)

Options

4' Arm length


6' Arm Length2
8' Arm Length2

Standard Finish
SA Satin Aluminum
(standard w/ AMAW)
GALV Galvanized Steel (standard w/ SMAW)
Architectural Colors (powder finish)1
Standard Colors
DDB Dark Bronze
DWH White
DBL Black

Notes:
1 Other colors available, please contact
your local American Electric Lighting
representative.
2 Not available with AMAWT14.

224

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

AMAC / SMAC
AMAC: Aluminum Mounting Arm, Concrete Poles
SMAC: Steel Mounting Arm, Concrete Poles
P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

AMAW / SMAW
AEL Catalog Number

Nominal
Arm Length
(feet)

Dimensions
(inches)
A

Weight
(pounds)

(Max per arm)


EPA ft2 w/ 1.3 gust
up to 100mph

Max Weight
per arm
(lbs)

76

AMAC T14 US4


AMAC T20 US4
AMAC T20 US6
AMAC T20 US8

4'
4'
6'
8'

42"
42"
66"
90"

18"
18"
24"
30"

10"
10"
12"
15"

6
8
11
14

2
276
2
276

SMAC T14 US4


SMAC T14 US6
SMAC T14 US8
SMAC T20 US4
SMAC T20 US6
SMAC T20 US8

4'
6'
8'
4'
6'
8'

42"
66"
90"
42"

18"
24"
30"
18"
66"
30"

10"
12"
15"
10"
24"
15"

13
17
21
18
12"
30

2
276
2
2
24
2

90"

IMPORTANT:
These specifications are intended for general purposes only. American
Electric Lighting reserves the right to change material or design, without
prior notice, in a continuing effort to upgrade its products.

76

76
76
76
276
76

CAUTION:
The arms described herein are designed for applications in areas of normal
winds. Consult the factory prior to the design of systems to be mounted on
structures such as bridges or buildings, or areas known to have abnormal
winds such as airports or coastal areas. Failure to consider these factors
in the system design could result in the failure of the pole or mast arm, and
consequently personal injury or property damage.

Product Guide

225

SMAWL
Mounting Arm
Steel Mounting Arm, Wall Mount

P R O D U C T

O V E R V I E W

O R D E R I N G

Intended Use

I N F O R M AT I O N

Finish galvanized steel is standard. Optional polyester powder paint


finishes available.

Wall-mounting roadway fixtures

Hardware not included

Features
Construction Body is galvanized steel tube (per ASTM A-123)
constructed from A500 Grade B steel.
Welding follows AWS standards. Arms are galvanized after
fabrication.

Example: S M A W L T 2 0 U S 4 G A L V A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option

SMAWL
Pipe Size

Series
SMAWL

T14
T20

1 - 2/3 O.D. (1 - 1/4 NPS)


2 - 3/8 O.D. (2 NPS)

US2-5
US4
US6
US8

Arm Length (feet)

Options

2 1/2'Arm Length
4' Arm Length
6' Arm Length2
8' Arm Length2

Standard Finish
GALV Galvanized Steel (standard w/ SMAW)
Architectural Colors (powder finish)1
Standard Colors
DDB Dark Bronze
DWH White
DBL Black

Notes:
1 Other colors available, please contact
your local American Electric Lighting
representative.
2 Not available with AMAWT14.

226

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

SMAWL
Mounting Arm
Steel Mounting Arm, Wall Mount

P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

AMAW / SMAW
AEL Catalog Number

Nominal
Arm Length
(feet)

SMAWL T14 US2-5


SMAWL T14 US4
SMAWL T14 US6
SMAWL T20 US2-5
SMAWL T20 US4
SMAWL T20 US6
SMAWL T20 US8

2'6"
4'
6'
2'6"
4'
6'
8'

Dimensions
(inches)
A

30"
42"
66"
30"
42"

15"
19"
24"
15"
19"
66"
30"

10"
10"
12"
10"
10"
24"
15"

90"

Weight
(pounds)

(Max per arm)


EPA ft2 w/ 1.3 gust
up to 100mph

Max Weight
per arm
(lbs)

11
13
18
17
22
12"
38

2
2
2
2
2
30
2

76
76
76
76
76
276
76

IMPORTANT:

CAUTION:

These specifications are intended for general purposes only. American


Electric Lighting reserves the right to change material or design, without
prior notice, in a continuing effort to upgrade its products.

The arms described herein are designed for applications in areas of normal
winds. Consult the factory prior to the design of systems to be mounted on
structures such as bridges or buildings, or areas known to have abnormal
winds such as airports or coastal areas. Failure to consider these factors
in the system design could result in the failure of the pole or mast arm, and
consequently personal injury or property damage.

.562 Diameter
(4 PLCS.)

1"

C
1"
1/4" Plate

14" 12"

2"

1/4" x 2" Flat Bar

4"

Product Guide

227

Traditional Wood Pole Arms


Mast Arms & Brackets - Upsweep Arms
(For Horizontally Mounted Luminaires)

P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

Wood Pole Mounting


Catalog
Number

91-2401
92-2401
91-3001
92-3001
91-4801
92-4801
91-4802
92-4802
92-7201
91-7202
92-7202
94-9602
93-7201
94-7201
93-7202
94-9601
93-9602

228

Product Guide

Item

2' ARM -11/4 '' Aluminum, (Use with Nema Head only)
Dimensions: A-24'', B-123/4'', C-73/8''
2' ARM -11/4'' Steel, Class E
Dimensions: A-24'', B-123/4'', C- 73/8''
21/2' ARM -11/4'' Aluminum, (Use with NEMA head only)
Dimensions: A-27'', B-123/4'', C-73/8''
21/2' ARM -11/4'' Steel, Class E
Dimensions: A-27'', B-123/4'', C-73/8''
4' ARM -11/4'' Aluminum, Class B
Dimensions: A-43'', B-213/4'', C-87/8''
4' ARM -11/4'' Steel, Class E
Dimensions: A-43'', B-211/2'', C-85/8''
4' ARM -2'' Aluminum, Class D
Dimensions: A-43'', B-211/4'', C-85/8''
4' ARM -2'' Steel, Class E
Dimensions: A-43'', B-211/2'', C-87/8''
6' ARM -11/4'' Steel, Class C
Dimensions: A-661/4'', B-291/2'', C-83/8''
6' ARM -2'' Aluminum, Class B
Dimensions: A-661/4'', B-291/2'', C-83/8''
6' ARM -2'' Steel, Class D
Dimensions: A-661/4'', B-291/2'', C-83/4''
8' ARM -2'' Steel, Class D
Dimensions: A-901/4'', B-297/8'', C-81/2''
6' ARM -11/4'' Aluminum, Class B
Dimensions: A-661/4'', B-291/2'', C-83/4''
6' ARM -11/4'' Steel, Class E
Dimensions: A-661/4'', B-291/2'', C-83/4''
6' ARM -2'' Aluminum, Class D
Dimensions: A-661/4'', B-29'', C-77/8''
8' ARM -11/4'' Steel, Class C
Dimensions: A-901/4'', B-291/2'', C-83/4''
8' ARM -2'' Aluminum, Class B
Dimensions: A-901/4'', B-291/2'', C-77/8''

For more information please visit our website:


www.americanelectriclighting.com

Approx.
Wt. (Lbs.)

1-3/4
5-1/2
2
6
3-3/4
10
6-1/2
17-1/2
17-1/2
9
25-1/2
40
6-3/4
18
11
26-1/2
13-1/2

Traditional Concrete Pole Arms


Mast Arms & Brackets - Upsweep Arms
(For Horizontally Mounted Luminaires)

P R O D U C T

O V E R V I E W

O R D E R I N G

I N F O R M AT I O N

Concrete Pole Mounting


Catalog

Approx.
Item

Number

90-2001

20 ARM -1'' Steel, Class E


Dimensions: A-20'', B-15'', C-12''
4' ARM -1'' Steel, Class E
Dimensions: A-48'', B-25'', C-12''
6' ARM -2'' Steel, Class D
Dimensions: A-72'', B-34'', C-12''
8' ARM -2'' Steel, Class D
Dimensions: A-96'', B-34'', C-12''

90-4801
90-7202
90-9602

Wt. (Lbs.)

10
16
29
48

Notes:
1. CLASS CHART Denotes the maximum size luminaire recommended for use.
Both weight and projected area must be considered. Classifications based on
American Electric Lighting standards. See Isotach Wind Map, page 189.
Luminaire Class
Weight (in pounds)
Effective Projected Area

A
30
1.5

B
40
2.0

C
60
3.0

D
80
4.0

E
100
5.0

2. Steel mast arms constructed in accordance with ASTM specification A-36.


3. For more information, please contact your local American Electric Lighting
representative.
CAUTION: The poles and mast arms described herein are designed for ground
mounted applications in areas of normal winds. Consult the factory prior to the
design of systems to be mounted on structures such as bridges or buildings, or
areas known to have abnormal winds such as airports or coastal areas. Failure
to consider these factors in the system design could result in the failure of the
pole or mast arm, and consequently personal injury or property damage.

Product Guide

229

NOTES

230

Product Guide

For more information please visit our website:


www.americanelectriclighting.com

TECHNICAL DATA, TERMS AND CONDITIONS


HPS Replacement Starters...................................232
Lamp Selection .......................................................233
Fuse Ratings ....................................................234-239
Luminaire Classification Systems........................240
Floodlighting Applications. ...................................241
Floodlighting Calculations.....................................242
Roadway Lighting Calculations............................243
Terms & Conditions ........................................244-245
Index .................................................................246-247

For technical support, please call:

1-800-754-0463
or email:
AELtechsupport@americanelectriclighting.com

www.americanelectriclighting.com

231

Technical Data
H P S

R E P L A C E M E N T

S T A R T E R S

Catalog Number

Description

IGN 3L 36 OB 50/150

3 Lead 3/16 Terminal Open Board 55V

IGN 3L 36 OB 200/400

3 Lead 3/16 Terminal Open Board 100V

IGN 3L 14 OP 50/150

3 Lead 1/4 Terminal Open Plug 55V

IGN 3L 14 OP 200/400

3 Lead 1/4 Terminal Open Plug 100V

IGN 3L 14 EC 50/150

3 Lead 1/4 Terminal Encapsulated 55V

IGN 3L 14 EC 200/400

3 Lead 1/4 Terminal Encapsulated 100V

IGN 2L 36 OB 50/150

2 Lead 3/16 Terminal Open Board 55V

IGN 2L 36 OB 200/400

2 Lead 3/16 Terminal Open Board 100V

IGN 2L 14 OP 50/150

2 Lead 1/4 Terminal Open Plug 55V

IGN 2L 14 OP 200/400

2 Lead 1/4 Terminal Open Plug 100V

IGN 2L 14 EC 50/150

2 Lead 1/4 Terminal Encapsulated 55V

IGN 2L 14 EC 200/400

2 Lead 1/4 Terminal Encapsulated 100V

IGN 2L 36 OB DUAL 50/400

2 Lead 3/16 Terminal Open Board Dual 55/100V

IGN 2L 14 OP DUAL 50/400

2 Lead 1/4 Terminal Open Plug Dual 55/100V

IGN 2L 14 EC DUAL 50/400

2 Lead 1/4 Terminal Encapsulated Dual 55/100V

IGN 2L 14 EC DUAL UNI

2 Lead 1/4 Terminal Encapsulated Dual Universal

IGN 2L 14 OP DUAL UNI

2 Lead 1/4 Terminal Open Plug Dual Universal

Notes:
1

232

Product Guide

Ships as 55V, converts to 100V by removing jump wire.

For photometric information please visit our website:


www.americanelectriclighting.com

Technical Data
L A M P

Typical Lamp Types

Lamp Comparison

with Watts and Initial Lamp Lumens

Quartz
Incandescent

Low Pressure
Sodium

Metal
Halide

High Pressure
Sodium

Efficiency

Poor
20 LPW

Best
183 LPW

Good
90 LPW

Better
105 LPW

Mean Life

Low
2K Hrs

Medium
18K Hrs

High
12K Hrs

High
24K Hrs

Lumen
Maintenance

High
97%

High
100%(+9)

Medium
80%

High
90%

Color

Best

Very Poor
Monochrome

Good

Fair

System C.U.

Good

Fair

Good

Good

Hot Restart

Instant

1 Minute

15 Minutes

1 Minute

Warm-Up

Instant

10 Minutes

10 Minutes*

5 Minutes

System Cost

Lowest

High

High

High

*Pulse Start MH

Recommended Minimum Mounting


Heights for Various Lamps
High Pressure
Sodium Lamp

50W
70W
100W
150W
200W
250W
310W
400W
1000W

S E L E C T I O N

Metal Halide
Lamp

175W

400W
1000W

Minimum Mounting
Height (Ft)

Lamp
Type

High
Pressure
Sodium

Watts

Initial
Lumens

Mean
Lumens

Avg. Life

35
50
70
100
150
200
250
310
400
1000

2250
4000
6300
9500
16000
22000
29000
37000
50000
130000

2025
3600
5500
8000
13800
19800
26100
32300
45000
120700

24000
24000
24000
24000
24000
24000
24000
24000
24000
24000

12800
20000
32000
32000
107800
153000

9300
14100
20500
20500
86000
127400

7500
7500
15000
15000
12000
3000

16000
23800
32000
37000
41000
120000

112000
16600
21000
28000
32800
96000

150000
15000
15000
20000
20000
20000

175
250
Metal
400
Halide
400 (BT28)
(Horizontal) 1000
1500
Pulse
Start
Metal
Halide
(Horizontal)

175
250
320
350
400
1000

8.0
12.0
15.0
18.0
20.0
25.0
30.0
35.0
40.0

Maintenance Factors
If maintained footcandle level is desired, multiply the area
coverage per fixture by the maintenance factor.
Maintenance factor is determined by multiplying the lamp
lumen depreciation factor (LLD) by the luminaire dirt
depreciation factor (LDD). The lamp lumen depreciation
factor is usually the mean lumen value of the lamp. The
luminaire dirt depreciation factor range is described in
the Illuminating Engineering Society Handbook. A .9 dirt
factor is commonly used.

Product Guide

233

Technical Data
F U S E

R A T I N G S

Nominal
Lamp
Wattage
(watts)
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
15S

E N E R G Y

Ballast
Circuit
RN
RH
XN
XN
XN
XH
XH
XH
CA
CA
CA
CA
CA
CT
CT
CT
MR
MR
MR
RN
RH
XN
XN
XN
XH
XH
XH
CA
CA
CA
CA
CA
CA
CT
CT
CT
CT
MR
MR
MR
RN

Supply
Voltage
(volts)
120
120
208
240
277
208
240
277
120
208
240
277
480
120
208
240
120
240
480
120
120
208
240
277
208
240
277
120
208
240
277
347
480
120
208
240
277
120
240
480
120

C O N S U M P T I O N

Input
Watts
(watts)
86
86
91
91
91
91
91
91
95
95
95
95
95
95
95
95
103
103
103
115
115
130
130
130
130
130
130
138
138
138
138
138
138
130
130
130
130
138
138
138
170

Current
(amps)
2.10
1.30
1.53
1.35
1.17
0.85
0.75
0.65
0.90
0.53
0.48
0.43
0.23
0.86
0.50
0.43
0.90
0.45
0.23
3.05
1.80
2.25
1.98
1.53
1.25
1.10
0.85
1.18
0.70
0.60
0.50
0.40
0.29
1.22
0.70
0.61
0.52
1.20
0.60
0.30
4.50

# of Fuses
1
1
2
2
1
2
2
1
1
2
2
1
2
1
2
2
1
2
2
1
1
2
2
1
2
2
1
1
2
2
1
1
2
1
2
2
1
1
2
2
1

Fuse
Rating
(Amps)
8
3
5
3
3
3
2
2
3
2
2
2
2
3
2
2
3
2
2
10
5
10
5
5
3
3
3
3
3
2
2
2
2
3
2
2
2
3
2
2
15

Notes
1

234

Product Guide

Based on $.10/KWH; 12 months operation

For photometric information please visit our website:


www.americanelectriclighting.com

Annual
Energy
Consumption
($)1
$37.67
$37.67
$39.86
$39.86
$39.86
$39.86
$39.86
$39.86
$41.61
$41.61
$41.61
$41.61
$41.61
$41.61
$41.61
$41.61
$45.11
$45.11
$45.11
$50.37
$50.37
$56.94
$56.94
$56.94
$56.94
$56.94
$56.94
$60.44
$60.44
$60.44
$60.44
$60.44
$60.44
$56.94
$56.94
$56.94
$56.94
$60.44
$60.44
$60.44
$74.46

Technical Data
F U S E
Nominal
Lamp
Wattage
(watts)
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
17M
17M
17M
17M
17M
17M
17M
17M
17M
17M
17M
17M
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S

Ballast
Circuit
RH
XN
XN
XN
XH
XH
XH
CA
CA
CA
CA
CA
CT
CT
CT
CT
MR
MR
MR
CA
CA
CA
CA
CA
CA
SC
SC
SC
SC
SC
SC
XN
XH
RN
RH
CA
CA
CA
CA
CA
CA

Supply
Voltage
(volts)
120
208
240
277
208
240
277
120
208
240
277
480
120
208
240
277
120
240
480
120
208
240
277
347
480
120
208
240
277
347
480
120
120
240
240
120
208
240
277
347
480

R A T I N G S

Input
Watts
(watts)
170
188
188
188
188
188
188
190
190
190
190
188
190
190
190
190
196
196
196
213
213
213
213
213
213
208
208
208
208
208
206
240
240
218
218
240
240
240
240
240
240

Current
(amps)
2.35
2.88
2.52
2.25
1.60
1.40
1.25
1.65
0.95
0.82
0.72
0.42
1.76
1.01
0.88
0.76
1.70
0.90
0.40
1.80
1.10
0.90
0.78
0.62
0.51
1.80
1.05
0.90
0.80
0.65
0.45
6.27
3.48
2.80
1.56
2.22
1.28
1.11
0.96
0.77
0.56

E N E R G Y

# of Fuses
1
2
2
1
2
2
1
1
2
2
1
2
1
2
2
1
1
2
2
1
2
2
1
1
2
1
2
2
1
1
2
1
1
2
2
1
2
2
1
1
2

Fuse
Rating
(Amps)
8
10
10
8
5
5
5
5
3
3
3
2
5
3
3
3
5
3
2
5
3
3
2
2
2
5
3
3
3
3
2
20
10
10
5
10
5
5
3
3
2

C O N S U M P T I O N
Annual
Energy
Consumption
($)1
$74.46
$82.34
$82.34
$82.34
$82.34
$82.34
$82.34
$83.22
$83.22
$83.22
$83.22
$82.34
$83.22
$83.22
$83.22
$83.22
$85.85
$85.85
$85.85
$93.29
$93.29
$93.29
$93.29
$93.29
$93.29
$91.10
$91.10
$91.10
$91.10
$91.10
$90.23
$105.12
$105.12
$95.48
$95.48
$105.12
$105.12
$105.12
$105.12
$105.12
$105.12

Notes:
1

Based on $.10/KWH; 12 months operation

Product Guide

235

Technical Data
F U S E

R A T I N G S

Nominal
Lamp
Wattage
(watts)
20S
20S
20S
20S
20S
20S
20S
20S
20M
20M
20M
20M
20M
20M
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25M
25M
25M
25M
25M
25M
25M
25M

E N E R G Y

Ballast
Circuit
CT
CT
CT
CT
CT
MR
MR
MR
SC
SC
SC
SC
SC
SC
XN
XH
RN
RH
CA
CA
CA
CA
CA
CA
CT
CT
CT
CT
CT
CT
MR
MR
MR
CA
CA
CA
CA
CA
CA
CT
CT

Supply
Voltage
(volts)
120
208
240
277
480
120
240
480
120
208
240
277
347
480
120
120
240
240
120
208
240
277
347
480
120
208
240
277
347
480
120
240
480
120
208
240
277
347
480
120
240

C O N S U M P T I O N

Input
Watts
(watts)
235
235
235
235
235
255
255
255
232
232
232
232
232
232
287
287
282
282
295
295
295
295
295
310
300
300
300
300
300
300
310
310
310
298
298
298
298
295
295
295
295

Current
(amps)
2.10
1.21
1.05
0.91
0.52
2.20
1.10
0.55
2.00
1.20
1.00
0.85
0.70
0.50
8.73
4.85
4.00
2.22
2.50
1.50
1.30
1.10
0.93
0.63
2.75
1.60
1.38
1.19
0.92
0.69
2.80
1.40
0.70
2.50
1.45
1.25
1.10
0.90
0.63
2.66
1.54

# of Fuses
1
2
2
1
2
1
2
2
1
2
2
1
1
2
1
1
2
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
2
2
1
1
2
1
2

Fuse
Rating
(Amps)
10
3
3
3
2
10
3
2
5
3
3
3
2
2
22
15
10
10
10
5
5
5
3
2
10
5
5
5
3
2
10
5
2
10
5
5
5
3
2
10
5

Notes:
1

236

Product Guide

Based on $.10/KWH; 12 months operation

For photometric information please visit our website:


www.americanelectriclighting.com

Annual
Energy
Consumption
($)1
$102.93
$102.93
$102.93
$102.93
$102.93
$111.69
$111.69
$111.69
$101.62
$101.62
$101.62
$101.62
$101.62
$101.62
$125.71
$125.71
$123.52
$123.52
$129.21
$129.21
$129.21
$129.21
$129.21
$135.78
$131.40
$131.40
$131.40
$131.40
$131.40
$131.40
$135.78
$135.78
$135.78
$130.52
$130.52
$130.52
$130.52
$129.21
$129.21
$129.21
$129.21

Technical Data
F U S E

Nominal
Lamp
Wattage
(watts)
25M
25M
25M
25M
25M
31S
31S
31S
31S
31S
31S
31S
31S
32M
32M
32M
32M
32M
32M
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40M

Ballast
Circuit
CT
SC
SC
SC
SC
CA
CA
CA
CA
CA
MR
MR
MR
SC
SC
SC
SC
SC
SC
RN
RH
RN
RH
XN
XH
CA
CA
CA
CA
CA
CA
CT
CT
CT
CT
CT
CT
MR
MR
MR
CA

Supply
Voltage
(volts)
480
120
208
240
277
120
208
240
277
480
120
240
480
120
208
240
277
347
480
208
208
240
240
120
120
120
208
240
277
347
480
120
208
240
277
347
480
120
240
480
120

R A T I N G S

Input
Watts
(watts)
295
291
291
291
291
365
365
365
365
365
380
380
380
368
368
368
368
368
368
440
440
440
440
463
463
464
464
464
464
464
464
465
465
465
465
465
465
490
490
490
458

Current
(amps)
1.33
2.50
1.45
1.25
1.10
3.37
1.94
1.68
1.45
0.84
3.30
1.65
0.83
3.25
1.90
1.65
1.40
1.10
0.80
5.20
2.89
6.00
3.33
6.70
3.72
3.80
2.20
1.90
1.70
1.32
0.97
4.20
2.40
2.10
1.82
1.45
1.05
4.20
2.10
1.05
4.00

E N E R G Y

# of Fuses
2
1
2
2
1
1
2
2
1
2
1
2
2
1
2
2
1
1
2
2
2
2
2
1
1
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1

Fuse
Rating
(Amps)
5
10
5
5
5
10
5
5
5
3
10
5
3
10
5
5
5
5
2
15
10
15
10
20
10
10
10
5
5
5
3
15
10
10
5
5
5
15
10
5
10

C O N S U M P T I O N

Annual
Energy
Consumption
($)1
$129.21
$127.46
$127.46
$127.46
$127.46
$159.87
$159.87
$159.87
$159.87
$159.87
$166.44
$166.44
$166.44
$161.18
$161.18
$161.18
$161.18
$161.18
$161.18
$192.72
$192.72
$192.72
$192.72
$202.79
$202.79
$203.23
$203.23
$203.23
$203.23
$203.23
$203.23
$203.67
$203.67
$203.67
$203.67
$203.67
$203.67
$214.62
$214.62
$214.62
$200.60

Notes:
1

Based on $.10/KWH; 12 months operation

Product Guide

237

Technical Data
F U S E

R A T I N G S

Nominal
Lamp
Wattage
(watts)
40M
40M
40M
40M
40M
40M
40M
40M
40M
40M
40M
40M
40M
40M
40M
75S
75S
75S
75M
75M
75M
75M
75M
75M
75M
X1S
X1S
X1S
X1S
X1S
X1S
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X1M

E N E R G Y

Ballast
Circuit
CA
CA
CA
CA
CA
CT
CT
CT
CT
CT
CT
SC
SC
SC
SC
CA
CA
CA
CA
CA
CA
CA
SC
SC
SC
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
SC
SC
SC
SC

Supply
Voltage
(volts)
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
120
208
240
820
820
820
820
120
208
240
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277

C O N S U M P T I O N

Input
Watts
(watts)
458
458
458
460
462
465
465
465
465
462
465
452
452
452
452
840
840
840
120
208
240
277
812
812
812
1100
1100
1100
1100
1100
1100
1070
1070
1070
1070
1070
1080
1080
1080
1080
1080

Current
(amps)
2.30
2.00
1.75
1.40
1.00
4.00
2.31
2.00
0.87
1.35
1.00
3.80
2.20
1.90
1.65
6.75
4.00
3.50
6.90
3.85
3.45
3.00
7.00
4.00
3.50
9.50
5.50
4.75
4.15
3.30
2.30
9.00
5.20
4.50
3.90
3.20
2.25
9.00
5.20
4.50
3.90

# of Fuses
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
2
1
2
2
1
1
2
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1

Fuse
Rating
(Amps)
10
5
5
5
3
10
10
5
3
5
3
10
10
5
5
20
10
10
20
10
10
10
20
10
10
30
15
15
15
10
10
30
15
15
10
10
10
30
15
15
10

Notes:
1
2

238

Product Guide

Based on $.10/KWH; 12 months operation


Based on $.10/KWH; 4 months operation

For photometric information please visit our website:


www.americanelectriclighting.com

Annual
Energy
Consumption
($)1
$200.60
$200.60
$200.60
$201.48
$202.36
$203.67
$203.67
$203.67
$203.67
$202.36
$203.67
$197.98
$197.98
$197.98
$197.98
$367.92
$367.92
$367.92
$52.56
$91.10
$105.12
$121.33
$355.66
$355.66
$355.66
$481.80
$481.80
$481.80
$481.80
$481.80
$481.80
$156.222
$156.222
$156.222
$156.222
$156.222
$157.682
$157.682
$157.682
$157.682
$157.682

Technical Data
F U S E
Nominal
Lamp
Wattage
(watts)
X1M
X1M
X5M
X5M
X5M
X5M
X5M
X5M

Ballast
Circuit
SC
SC
CA
CA
CA
CA
CA
CA

Supply
Voltage
(volts)
347
480
120
208
240
277
347
480

R A T I N G S

Input
Watts
(watts)
1080
1070
1605
1605
1605
1605
1615
1625

Current
(amps)
3.20
2.25
13.50
7.80
6.75
5.58
4.80
3.40

E N E R G Y

# of Fuses
1
2
1
2
2
1
1
2

Fuse
Rating
(Amps)
10
10
N/A
20
20
15
15
10

C O N S U M P T I O N

Annual
Energy
Consumption
($)1
$157.682
$156.222
$234.332
$234.332
$234.332
$234.332
$235.792
$237.252

Notes:
1
2

Based on $.10/KWH; 12 months operation


Based on $.10/KWH; 4 months operation

Product Guide

239

Technical Data
L U M I N A I R E

WIDTH
CLASSIFICATION

Mounted at
Pavement

Type I

Center

Type II

Edge

C L A S S I F I C A T I O N

S Y S T E M S

Normally Used for:

TYPE I

Roadways up to 2 times the


mounting height in width
Up to 1 times the mounting height
for one side mounting
Up to 2 times the mounting height
for both side mounting

Type III

Edge

Up to 1.5 times the mounting


height for one side mounting
Up to 3 times the mounting height
for both side mounting

Type IV

Edge

Up to 2 times the mounting height


for one side mounting
Up to 4 times the mounting height
for both side mounting

Type V

Center

Up to 4 times the mounting height


in total width

TYPE I - 4 Way

TYPE II

TYPE II - 4 Way

240

SPACING
CLASSIFICATION

Definition

Short

Medium

Spacings up to 5 times mounting


height

Long

Spacings up to 5 times mounting


height

Normally Used for:

Spacings up to 4 times
the mounting height

GLARE CONTROL
CLASSIFICATION

Definition

FCO

Full-Cutoff

Strict control of light above


80 Vertical
Zero emission above 90 Vertical

CO

Cutoff

Strict control of light


above 80 Vertical
2.5% emission above 90 Vertical

SCO

Semi-Cutoff

Medium control of light


above 80 Vertical

NCO

Non-Cutoff

No control requirements
above 80 Vertical

Product Guide

Normally Used for:

For photometric information please visit our website:


www.americanelectriclighting.com

TYPE III

TYPE IV

TYPE V

Technical Data
F L O O D L I G H T I N G

IES Classifications

Setback

The IES beam spreads indicate the angular


ranges (horizontally and vertically) through
which the intensity of the floodlight is greater
than 10% of its maximum intensity. This angular range is referred to as the 'Field Angle'.
For example:
Asymmetrical beam spread
138 (H) x 119 (V)
HORIZONTAL

The recommended setback is three-fourth


the building height. If a building is 30 feet tall,
the recommended setback is 22.5 feet from
the building. Locating the floodlight closer to
the building will sacrifice uniformity; setting
it farther back will result in a loss of efficiency.
Setback distance = 3/4 x building height
3
/4 (30 ft.) = 22.5 ft.

IES
Type

Beam
Description
Spacing

1
2
3
4
5
6
7

Sign Lighting
Considerations:
1. Setback
2. Spacing
3. Aiming
Setback

IES Beamspread Classification

10 up to 18
18 up to 29
29 up to 46
46 up to 70
70 up to 100
100 up to 130
130 and up

Sign Lighting
When lighting a sign with ground-mounted
floodlights, there are three considerations:
setback, spacing and aiming.

VERTICAL

= IES 7 X 6

Field
Angle
Degrees

A P P L I C A T I O N S

Very Narrow
Narrow
Medium Narrow
Medium
Medium Wide
Wide
Very Wide

The rule of thumb for spacing floodlights is not


to exceed two times the setback distance. If
the setback is 22.5 feet, the floodlights should
not be placed more than 45 feet apart.

When using ground-mounted floodlights to


light a sign, the recommended setback is a distance equal to three-fourth the sign height. For
example, the setback distance for a 12-foot by
6-foot sign would be 4.5 feet. Locating the
floodlight closer will sacrifice uniformity while
setting it farther back will result in a loss of efficiency.
Setback distance = 3/4 x sign height
3
/4 (6 ft.) = 4.5 ft.

Spacing = 2 x setback distance


22.5 ft. x 2 = 45 ft. apart

The IES classification was formerly referred


to as NEMA Type.
The following outdoor design tips provide
general guidelines for lighting design. These
guidelines may not apply to all applications.
GROUND-MOUNTED FLOODLIGHTS
Ground-mounted floodlights are used to light
building facades, signs and flagpoles.

Facade Lighting
When lighting building facades with groundmounted floodlights, three factors are considered: setback, spacing and aiming.

Facade Lighting
Considerations:
1. Setback
2. Spacing
3. Aiming

Spacing
Aiming
The floodlight should be aimed at least twothirds the height of the building. For example,
if a building is 30 feet high, the recommended
aiming point is approximately 20 feet high.
After installation is complete, aiming can be
adjusted to produce the best appearance.
Mounting a full or upper visor to the floodlight
can reduce unwanted spill light.

The rule of thumb for spacing floodlights is not


to exceed two times the setback distance. If
the setback is 4.5 feet, the floodlights should
not be placed more than 9 feet apart.
Spacing = 2 x setback distance
4.5 ft. x 2 = 9 ft. apart

Aiming point = 2/3 x building height


2
/3 (30 ft.) = 20 ft. high

Product Guide

241

Technical Data
F L O O D L I G H T I N G
Aiming
The floodlight should be aimed at least twothirds up the sign. For example, if a sign is six
feet tall, then the floodlight will be aimed approximately four feet high. After installation
is completed, aiming can be adjusted to produce the best appearance. Mounting a full or
upper visor to the floodlight can reduce unwanted glare.

C A L C U L A T I O N S
Spacing

Spacing

Ideally, three floodlights are recommended to


light a flag. The floodlights should be placed
approximately 120 apart.

When more than one pole is added, pole


placement is a concern. The "4 times" rule of
thumb for spacing indicates that a pole should
be placed four times the mounting height from
the adjacent poles. If a flood is mounted on a
20-foot pole, space the poles 80 feet apart.

3 floodlights spaced 120 apart

Pole spacing = 4 x mounting height


4 (20-ft. pole) = 80 feet between poles

Aiming point = 2/3 x sign height


2/3 (6 ft.) = 4 ft. high

Aiming
The recommended aiming point for each
floodlight is the center of the flag or the top of
the pole. Mounting a full or upper visor to the
floodlight can reduce unwanted spill light.
Flag Lighting
Ground-mounted floodlights also can be used
to light flags. Setback, spacing and aiming
must all be considered.

Vertical Aiming
A single floodlight uses the two-thirds rule of
thumb for vertical aiming. The fixture is aimed
2/3 of the distance across the area to be
lighted and at least 30 below horizontal. If the
area to be lighted is 40 feet across, the
recommended aiming point is 27 feet.
Aiming point = 2/3 across distance to be lighted
2
/3 (40 ft.) = 27 ft. aiming point

Flag Lighting
Considerations:
1. Setback
2. Spacing
3. Aiming

Setback
The recommended setback for lighting a flag
is one-third times the pole height. If the pole
is 30 feet tall, the floodlight should be set
back a distance of 10 feet away from the pole.
Setback distance = 1/3 x pole height
1
/3 (30 ft.) = 10 ft.

POLE-MOUNTED FLOODLIGHTS
General Area Lighting
Pole-mounted floodlights are commonly used
for general area lighting applications such as
parking lots and storage yards. Mounting
height, spacing, vertical aiming and horizontal aiming should be considered.
General Lighting
Considerations:
1. Mtg. Height
2. Spacing
3. Vertical aiming
4. Horizontal aiming

Additionally, to minimize glare, the


recommended aiming point distance should
never exceed twice the mounting height. If a
pole is 20 feet high, the vertical aiming point
should not exceed 40 feet out.
2 (20 ft. mtg. ht.) = 40 ft.
Horizontal Aiming

Mounting Height

'

The recommended mounting height is one half


the distance across the area to be lighted. If
the area to be lighted is 40 feet across, the
lowest recommended mounting height is 20
feet.

'

Mounting height = 1/2 distance to be lighted


1
/2 (40ft.) = 20 ft.

242

Product Guide

When an additional floodlight is added to a single pole, horizontal aiming also must be considered. First, each floodlight should be
vertically aimed according to the two-thirds
rule. As long as the floodlight has a horizontal
NEMA 6 or 7 beamspread, the floodlights can
be aimed up to 90 apart.

Technical Data
R O A D W A Y

L I G H T I N G

C A L C U L A T I O N S

American Electric Lighting offers an extensive line of luminaires for your roadway lighting applications. The calculations which follow will help
you to determine the type, quantity and placement of these luminaires. You will need data from the Photometric Test Report for the luminaire(s)
being considered. Contact your American Electric Lighting representative for these reports. A sample report is provided for your use in the
following calculations.

Calculations
Initial Lamp
Coefficient of
Light Loss
Lumens
x Utilization
x Factor

Average
Maintained =
Footcandles
Pole
Spacing

Pole Spacing x Road Width


Initial Lamp
Coefficient of
Light Loss
Lumens
x Utilization
x Factor

Average Maintained
Footcandles x

Initial
Lamp
Lumens

Averaged Maintained
Footcandles

Coefficient
Utilization

Pole
Spacing

x
x

Road
Width

Road
Width

Light Loss
Factor

SAMPLE CALCULATIONS
A roadway is to be lighted to a level of 1fc (Average Maintained Footcandles). The roadway is 45 feet wide and the poles are 30 feet high, therefore, the mounting
height ratio is 1.5
The Photometric Test Report provides: Initial Lamp Lumens = 14,000. Coefficient of Utilization (at 1.5MHR) = 43% for the 175W MH lamp used in an American Electric
Lighting LUXMASTER LUMINAIRE.
The Light Loss Factor provided in the preceding charts for the 175W MH lamp is 0.70. Initial Lamp Lumens are also provided in this chart.
Pole Spacing =

14,000 (ILL) x .43 (CU) x .70 (LLF)


= 94 Feet (PS)
1 (AMF) x 45 (RW)

If Pole Spacing is known, then Average Maintained Footcandles can be calculated:


Average Maintained Footcandles =

14,000 (ILL) x .43 (CU) x .70 (LLF)


= .996 (AMF)
94 (PS) x 45 (RW)

Or Initial Lamp Lumens can be calculated:


Initial Lamp Lumens =

1 (AMF) x 94 (PS) x 45 (RW)


= 14,000 (ILL)
.43 (CU) x .70 (LLF)

Other application data may be determined by similar calculations. Contact your local American Electric Lighting representative for assistance.
AMF - Average Maintained Footcandles
CU - Coefficient of Utilization
ILL - Initial Lamp Lumens
MHR - Mounting Height Ratio
LLF - Light Loss Factor
PS - Pole Spacing
RW - Road Width

Product Guide

243

TERMS AND CONDITIONS OF SALE


For Shipments Within the United States*
Effective August 25, 2008

TERMS:
The words we, our and us shall refer to American Electric Lighting (AEL) , a division of
Acuity Brands Lighting, Inc. and the words purchaser, you and your, shall refer to the
person or entity purchasing products under this Agreement.
PAYMENT TERMS:
A 1% cash discount will be allowed on invoices paid in full by the 10th of the month
following the month of billing. All payments made after the 10th are due on a net basis to
the 25th (1% 10th prox, net 25th prox).
FREIGHT ALLOWANCE:
Shipments are F.O.B. our plants, distribution centers or field warehouses as follows:
All factory orders having a distributor price of
$3,000 or more for one consignee for one release
qualify for freight allowed.

Warehouse orders of stock items having a


distributor price of $3,000 or more for one
consignee for one release qualify for freight allowed.

All orders having a distributor price of less than


$3,000 will be assessed freight and handling charges.

Anchor bolts are included with American Electric


Lighting poles. Pre-shipped anchor bolts having a
distributor price of less than $3,000 will be assessed
freight and handling charges.
We reserve the right to route all orders that qualify for freight allowance at our
discretion. AEL will ship in the manner selected by the purchaser provided that the
purchaser assumes all additional transportation costs.
DELIVERY:
AEL shall not be liable for any delay or default in delivering products for any reason
beyond the reasonable control of AEL, including, but not limited to, armed conflict or
economic dislocation resulting therefrom; embargoes; shortages of labor, raw materials,
fuels, energy, production facilities or transportation; labor difficulties, civil disorders of
any kind; action of civil or military authorities (including priorities and allocations); fires,
floods, and accidents. No liability shall be incurred by AEL by reason of its not filling any
order or portion thereof due to any of these or similar circumstances.
TRANSPORTATION CLAIMS:
AELs equipment is tested for mechanical defects prior to shipping. AELs packaging is
regularly inspected by transportation authorities who assume responsibility for both
apparent and concealed damages sustained by improper handling. Title passes to
purchaser upon delivery by AEL to the carrier, and all claims for damages or shortages in
transit shall be made by the purchaser to the delivering carrier. AEL will be glad to assist
when called upon, provided notification is given in writing within 15 business days of
receipt of shipment.
PACKAGING:
AEL reserves the right to alter the quantities of any order so as to conform to standard
packaging.
PRICES:
Prices are subject to change without notice. In the event of price increases, all orders
on hand will be filled at the lower prices provided that such orders are released for
shipping prior to the effective date of the price increase. If the orders are not released for
shipment prior to the effective date of the price increase, the orders will be billed at the
prices in effect at the time of shipment. Special quoted orders which cannot be released
for shipping prior to the price increase effective date may be subject to an increase in
price. Minimum billing is $100 net excluding orders for replacement parts only. Orders
for parts totaling less than $15 will be billed $15 lump sum. Prices do not include lamps
unless so specified.
RETURN MERCHANDISE:
No merchandise may be returned without prior written authorization from AEL factories.
Requests to return merchandise must be made with AELs agents for transmittal to the
factory within four (4) months from date of shipment by AEL. All returns must be shipped
prepaid to the location designated on the return authorization. Credit will be issued based
on the original invoice price, or price in effect at time of return, whichever is lower, less a
restocking charge of 25% (minimum) of the purchase price (to partially defray our cost of
handling), less reconditioning and replacing costs if necessary, and less the freight
expense of the original shipment. The reconditioning charge will be determined by the
amount of repairs, refinishing or reconditioning required to restore the merchandise to
saleable condition. All non-stocking, special, custom-made, outdated, or modified
versions of normal factory stocking items are not returnable. Authorization will not be
granted when the value of all items to be returned is less than $100. Returns from any
one order will be limited to not more than 10% of the total order value.

244

Product Guide

SERVICE AREA LIMITATION:


AEL reserves the right to refuse to make quotations, accept orders or make shipments to
points of destination outside of the regular or assigned selling and service area of the
distributor.
GUARANTEE:
AEL warrants all equipment to be free from defect in manufacturing, under normal and
proper storage, installation, and use, for a period of one (1) year. In addition we provide a
six (6) year warranty on the factory installed electrical system (which consists of the
ballast, ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and wiring) inside
AEL products. AELs guarantee liability extends only to the repair or replacement of the
defective part, at AELs option, and no labor charges for correction of the defect by repair
or replacement will be honored by AEL unless prior written authority has been granted by
AELs Customer Service Department.
THE FOREGOING GUARANTEE TERMS ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
GUARANTEES. AEL MAKES NO REPRESENTATIONS OR WARRANTIES EXCEPT AS
EXPRESSLY SET FORTH IN THESE TERMS AND CONDITIONS, AND AEL EXPRESSLY
DISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. NO DISTRIBUTOR OR SUPPLIER OF AEL HAS
THE AUTHORITY TO MODIFY OR AMEND THIS GUARANTEE.
LIMITATION OF LIABILITY:
The foregoing guarantee provides the purchasers sole and exclusive remedy relating to
AELs products. The total liability of AEL on any and all claims of any kind, whether in
contract, warranty, tort (including negligence), strict liability or otherwise, arising out of or
in connection with, or resulting from, AELs performance or breach of the foregoing limited
warranty or from AELs sale, delivery, repair, or replacement of any products, or the
furnishing of any services, shall in no event exceed the purchase price allocable to the
specific product which gives rise to the claim, and any and all such liability shall
terminate upon the expiration of the limited warranty set forth above. IN NO EVENT
SHALL AEL BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR
PUNITIVE DAMAGES, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES,
WHETHER AS THE RESULT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING
NEGLIGENCE), STRICT LIABILITY, OR ANY OTHER THEORY.
CANCELLATION CHARGES:
Orders for stocking items may be cancelled prior to shipping without charge. All other
orders may not be cancelled unless AEL is reimbursed for all work already performed and
for all special materials purchased by AEL. If an order is cancelled after shipment or if
delivery is refused at the delivery destination, all warehousing, delivery and return costs
will be charged to the purchaser.
GENERAL:
Possession of a price sheet does not entitle you to purchase any merchandise.
Specifications are subject to change without notice. Consult factory for verification. The
compliance of AELs product to individual project specifications and the approval for their
use is not warranted by AEL.
ACCEPTANCE:
Acceptance of orders can be made only at AELs plants, distribution centers or field
warehouses for warehouse orders on the basis of these terms and conditions of sale.
Acceptance of orders is limited to the terms and conditions hereof. AEL hereby objects to
any additional or different terms offered by the purchaser in its sales order or any other
document of purchaser. Such additional or different terms shall not become a part of any
order without the express written consent of AEL.
ENTIRE AGREEMENT:
Except as expressly agreed in writing signed by AEL, the terms and conditions stated
above shall constitute the entire sales agreement between AEL and the purchaser. Any
contrary or additional terms or conditions submitted by the purchaser (other than the
description of the products being ordered and the requested quantities, shipping date,
and shipping location contained in purchasers purchase order) shall be deemed to be of
no force or effect and are hereby rejected. Purchasers submission of a purchase order
shall indicate purchasers acknowledgment of and agreement with these Terms and
Conditions.
American Electric Lighting reserves the right to change these Terms and Conditions of
Sale without notice.
* For shipments outside the United States, contact factory for applicable
Terms and Conditions of Sale.

TERMS AND CONDITIONS OF SALE


For Shipments Within Canada*
Effective August 25, 2008

TERMS:

DROP SHIPMENTS:

The words we, our and us shall refer to American Electric Lighting Canada (AEL), a
division of Acuity Brands Lighting, Inc. and the words purchaser, you and your, shall refer
to the person or entity purchasing products under this Agreement.

AEL reserves the right to refuse to make direct shipments to points of destination outside
of the regular or assigned selling and service area of the distributor.

PAYMENT TERMS:

AEL warrants all equipment to be free from defect in manufacturing, under normal and
proper storage, installation, and use, for a period of one (1) year. In addition, AEL provides
a six (6) year warranty on the factory installed electrical system (which consists of the
ballast, ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and wiring) inside
AEL products. AELs guarantee liability extends only to the repair or replacement of the
defective part, at AELs option, and no labor charges for correction of the defect by repair
or replacement will be honored by AEL unless prior written authority has been granted by
AELs Customer Service Department.
THE FOREGOING GUARANTEE TERMS ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
GUARANTEES. AEL MAKES NO REPRESENTATIONS OR WARRANTIES EXCEPT AS
EXPRESSLY SET FORTH IN THESE TERMS AND CONDITIONS, AND AEL EXPRESSLY
DISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. NO DISTRIBUTOR OR SUPPLIER OF AEL HAS
THE AUTHORITY TO MODIFY OR AMEND THIS GUARANTEE.

Payment terms are 2% -10 or Net 30 days. 2%-10 days means that all invoices dated from
the first to the 15th of the month are payable on the 25th of the same month. All invoices
from the 15th to the 30th of the month are payable on the 10th of the following month.
Alternatively, all invoices are due Net 30 days following invoice date.
FREIGHT ALLOWANCE:
Shipments are F.O.B. our plants, Lachine, Quebec, and St. Hyacinthe, Quebec, and our
Canadian field warehouses.
Warehouse or factory orders must equal $3,000 U.S. or more for
shipment to one consignee for one release to qualify for freight allowance.
All orders having a distributor price of less than $3,000 U.S. will be assessed
freight and handling charges.
Special shipping requirements by the purchaser that cause additional
shipping expenses above the normal shipping expenses will be charged to
the purchaser.
DELIVERY:
AEL shall not be liable for any delay or default in delivering products for any reason
beyond the reasonable control of AEL, including, but not limited to, armed conflict or
economic dislocation resulting therefrom; embargoes; shortages of labor, raw materials,
fuels, energy, production facilities or transportation; labor difficulties, civil disorders of
any kind; action of civil or military authorities (including priorities and allocations); fires,
floods, and accidents. No liability shall be incurred by AEL by reason of its not filling any
order or portion thereof due to any of these or similar circumstances.
TRANSPORTATION CLAIMS:
Our equipment is tested for mechanical defects prior to shipping. Our packaging is
regularly inspected by transportation authorities who assume responsibility for both
apparent and concealed damages sustained by improper handling. Title passes to
purchaser upon delivery by AEL to the carrier, and all claims for damages or shortages in
transit shall be made by the purchaser to the delivering carrier. AEL will be glad to assist
when called upon, provided notification is given in writing within 15 business days of
receipt of shipment.
PACKAGING:
AEL reserves the right to alter quantities of any order so as to conform to standard
packaging.
PRICES:
Prices are subject to change without notice. In the event of price increases, all orders on
hand will be filled at the lower prices provided that such orders are released for
shipping prior to the effective date of the price increase. If the orders are not released for
shipment prior to the effective date of the price increase, the orders will be billed at the
prices in effect at the time of the shipment. Special quoted orders which cannot be
released for shipping prior to the price increase effective date may be subject to an
increase in price. Minimum billing is $100 net excluding orders for replacement parts
only. Orders for parts totaling less than $50 will automatically be billed $50 lump sum.
Prices do not include lamps unless so specified. Prices exclude all taxes.
RETURN MERCHANDISE:
No merchandise may be returned without prior written authorization from AEL factories.
Requests to return merchandise must be made with our agents for transmittal to the
factory within four (4) months from date of shipment by us. All returns must be shipped
prepaid to the location designated on the return authorization. Credit will be issued based
on the original invoice price, or price in effect at time of return, whichever is lower, less a
restocking charge of 25% (minimum) of the purchase price (to partially defray our cost of
handling), less reconditioning and replacing costs if necessary, and less the freight
expense of the original shipment. The reconditioning charge will be determined by the
amount of repairs, refinishing or reconditioning required to restore the merchandise to a
saleable condition. All non-stocking, special, custom-made, outdated, or modified
versions of normal factory stocking items are not returnable. Authorization will not be
granted when the value of all items to be returned is less than $100. Returns from any
one order will be limited to not more than 10% of the total order value.

GUARANTEE:

LIMITATION OF LIABILITY:
The foregoing guarantee provides the purchasers sole and exclusive remedy relating to
AELs products. The total liability of AEL on any and all claims of any kind, whether in
contract, warranty, tort (including negligence), strict liability or otherwise, arising out of or
in connection with, or resulting from, AELs performance or breach of the foregoing limited
warranty or from AELs sale, delivery, repair, or replacement of any products, or the
furnishing of any services, shall in no event exceed the purchase price allocable to the
specific product which gives rise to the claim, and any and all such liability shall terminate
upon the expiration of the limited warranty set forth above. IN NO EVENT SHALL AEL BE
LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR PUNITIVE
DAMAGES, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES, WHETHER AS
THE RESULT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE),
STRICT LIABILITY, OR ANY OTHER THEORY.
CANCELLATION CHARGES:
Orders for stocking items may be cancelled prior to shipping without charge. All other
orders may not be cancelled unless AEL is reimbursed for all work already performed and
for all special materials purchased by AEL. If an order is cancelled after shipment or if
delivery is refused at the delivery destination, all warehousing, delivery, and return costs
will be charged to the purchaser.
GENERAL:
Possession of a price sheet does not entitle you to purchase any merchandise. Specifications are subject to change without notice. Consult factory for verification. The compliance
of AELs product to individual project specifications and the approval for their use is not
warranted by AEL.
ACCEPTANCE:
Acceptance of orders can be made only at AELs plants, distribution centers or field
warehouses for warehouse orders on the basis of these terms and conditions of sale.
Acceptance of orders is limited to the terms and conditions hereof. AEL hereby objects to
any additional or different terms offered by the purchaser in its sales order or any other
document of purchaser. Such additional or different terms shall not become a part of any
order without the express written consent of AEL.
ENTIRE AGREEMENT:
Except as expressly agreed in writing signed by AEL, the terms and conditions stated
above shall constitute the entire sales agreement between AEL and the purchaser. Any
contrary or additional terms or conditions submitted by the purchaser (other than the
description of the products being ordered and the requested quantities, shipping date,
and shipping location contained in purchasers purchase order) shall be deemed to be of
no force or effect and are hereby rejected. Purchasers submission of a purchase order
shall indicate purchasers acknowledgment of and agreement with these Terms and
Conditions.
American Electric Lighting Canada reserves the right to change these Terms and
Conditions of Sale without notice.
*For shipments outside Canada, contact factory for applicable Terms and
Conditions of Sale.

Product Guide

245

Index

ACP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154


AMAC / SMAC / Arms for Concrete Poles . . . . . . . . . .224
AMAW / SMAW / Arms for Wood Poles . . . . . . . . . . . .222
ANSI Color Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
ASA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
AVL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
AVL-BIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
Accessories
Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
Floodlighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168
Photocontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
Roadway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
Aluminum Mounting Brackets . . . . . . . . . . . . . . . . . . . .203
American Revolution Deluxe Series . . . . . . . . . . . . . . . .62
American Revolution Series 247 . . . . . . . . . . . . . . . . . . . .64
AmeriSport Series ASP . . . . . . . . . . . . . . . . . . . . . . . .164

Bainbridge Series 870

. . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Ballast Matrices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
Decorative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Floodlighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173
Roadway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Branson . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84

Contempo Series 245

. . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Corvus CVM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Corvus CVL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Cresthill Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Cresthill Sphere . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Cresthill Centennial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Cresthill Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80

DP1704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
DPN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
DUX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
DX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179
Decorative Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Chadsworth Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
New Albany Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Statesboro Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94
Waycross Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Weatherproof Receptacles . . . . . . . . . . . . . . . . . . . . . .98
DuraStar Series 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
DuraStar Series 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Dusk To Dawn Series DTD . . . . . . . . . . . . . . . . . . . . . . . .114

Energy Saver Series CES

. . . . . . . . . . . . . . . . . . . . . . . .160

Georgian Series GRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66


Heavy-Duty Wallpack 882 . . . . . . . . . . . . . . . . . . . . . . . . .46
InterState II

775 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

LPS Roadway - SRX

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
LPS Roadway - SP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Lexington . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
LuxMaster Luminaire Series 53 . . . . . . . . . . . . . . . . . .136
LuxMaster Luminaire Series 153 . . . . . . . . . . . . . . . . .138
LuxMaster Classic Series LM . . . . . . . . . . . . . . . . . . . .142
LuxMaster Classic Series LS . . . . . . . . . . . . . . . . . . . .140

Marietta Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70


Multi-Mount 285 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

NEMA Head 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108


NEMA Head Package Series 11 PKG . . . . . . . . . . . . . .110

D7790 Series

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
DBE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
DD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
DE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178
DP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177

246

Product Guide

PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
PES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124
Photocontrol Recommendation Chart . . . . . . . . . . . . . .186
Pole Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202

For photometric information please visit our website:


www.americanelectriclighting.com

Index

Pole Technical Data


Florida Wind Rating . . . . . . . . . . . . . . . . . . . . . . . . . . .190
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Illustrated Samples . . . . . . . . . . . . . . . . . . . . . . . . . . .188
Wind Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189

Shorting and Open Caps . . . . . . . . . . . . . . . . . . . . . . . . .185


SignLite 875 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Steel Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . .204
Sportslighting Series SPF . . . . . . . . . . . . . . . . . . . . . . . .166
Sumter Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72

Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . . . . . . . . .162

Technical Data

Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . . . . . . . . .163

Floodlighting Applications. . . . . . . . . . . . . . . . . . . . . .241


Floodlighting Calculations . . . . . . . . . . . . . . . . . . . . .242
Fuse Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234-239
HPS Replacement Starters . . . . . . . . . . . . . . . . . . . . .232
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233
Luminaire Classification Systems . . . . . . . . . . . . . . .240
Roadway Lighting Calculations . . . . . . . . . . . . . . . . .243
Terms & Conditions . . . . . . . . . . . . . . . . . . . . . . . . . .244-245
Traditional Concrete Pole Arms . . . . . . . . . . . . . . . . . . .229
Traditional Wood Pole Arms . . . . . . . . . . . . . . . . . . . . . .228
TwistPack Series TWT . . . . . . . . . . . . . . . . . . . . . . . . . . . .88

RSA

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192
RTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193
RSAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194
RSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197
RTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198
RTAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216
RTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205
RTFDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206
RTSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220
Roadway 115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Roadway 115 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Roadway 125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Roadway 125 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Roadway 315 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Roadway 315 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Roadway 325 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Roadway 325 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Roadway 327 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

UltraFlood Series 75

. . . . . . . . . . . . . . . . . . . . . . . . . .156
UltraFlood Series 77 . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Underpass 581/681 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

VLR

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
VMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
Valiant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

SMAWL / Arms for Wall Mount

. . . . . . . . . . . . . . . . . . .226
SPRTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209
SPRTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213
SSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195
SSAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196
SSF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207
SSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
STC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
STS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200
STSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201
Series 11 L Package . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Series 165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116

Product Guide

247

NOTES

248

Product Guide

For photometric information please visit our website:


www.americanelectriclighting.com

NEW in Edition Three


Edition Three of the American Electric Lighting Product Guide introduces several new products, shown below.
Look for the NEW icon throughout the catalog to locate these new items.

NEW

CVM

CVL

ValiantTM

ARD

Page 10

Page 12

Page 60

Page 62

ASA

PES

PEM

VMR

VLR

Page 122

Page 124

Page 126

Page 128

Page 130

AVL BIA

ACP

CES

DP 1704

Page 132

Page 154

Page 160

Page 176

Sales Contact______________________________

AEL Customer #____________________________

Contact Email______________________________

Contact Phone _____________________________

To see available product literature, specification sheets, photometric reports and more, please visit us at:

www.americanelectriclighting.com
For Technical Support, contact us at:
1-800-754-0463 or AELtechsupport@americanelectriclighting.com

American Electric Lighting


Acuity Brands Lighting, Inc.
3825 Columbus Rd. S.W., Granville, OH 43023
Phone: 800-754-0463, Fax: 740-349-4490
www.americanelectriclighting.com

2008 Acuity Brands Lighting, Inc.

AEL-1315.17 4/08

Printed in USA

Você também pode gostar