Limits as per MPCB (Noise Regulation)

Industrial area: 75db Day Time


70db Night Time
Day Time:

06:00 AM to 10:00 PM

Night Time: 10:00 PM to 06:00 AM

Water Act Requirement


1. The company should have comprehensive treatment system consisting of primary / secondary & tertiary treatment
2. Quality of treated effluent should be as per MPCB prescribed standards:
pH: 5.5<9.0
Suspended solids: <101mg/L
BOD 3 Days 27 C: <100mg/L
COD: <251mg/L
Oil & Grease: <11mg/L
3. Trade effluent disposal : Treated effluent trade effluent should recycle to the maximum extend & remaining should be
used for the garden
4. Sewage effluent treatment: The applicant should provide comprehensive treatment system as is warented with reference to
effluent quality and & operate and maintain the same continuously to achieve the quantity of treated effluent to following
standards:
Suspended Solids: <101 mg/L
BOD 3 days 27 c: <100mg/L
5. Industry should monitor the effluent quality regularly

The Water (Prevention & Control of Pollution) Cess Act, 1977


REQUIREMNT

AFFIXING OF METERS

For the purpose of measuring and recording the quantity of water consumed, every
person carrying on any specified industry and every local authority shall affix meters
of such standard and at such a places as may be prescribed and it shall be presumed
that the quantity indicated by the meter has been consumed by such a person or local
authority, as the case may be, until the contrary is proved
Where any person or local authority fails to affix any meter as required by sub
section (I), The Central Government shall after notice to such a person or local
authority, as the case may be, cause such a meter to be affix and the cost of such a
meter together with the cost for affixing the meter may be recovered from such a
person or local authority by the central government in the same manner as an arrear
of land revenue

FURNISHING OF RETURNS IN
FORM NO. I

Every Person carrying on any specified industry and every local authority, liable to
pay the cess under section 3, shall furnish such returns, in such a forms at such a
intervals and containing such particulars to such officer or authority, as may be
prescribed.

If Person carrying on any specified industry or local authority , liable to pay the cess

under section 3, fails to furnish any return under sub section (1), The officer or the
authority shall give notice requiring such a person or local authority to furnish such a
returns before such a date as may be specified in the notice
Air Quality:

Table 1: National Ambient Air Quality Standards


Pollutants

Sulphur Dioxide (SO 2)

Time Weighted
Average

Annual

Industrial, Residential,
Rural & Other Area
50 g/m3

Concentration in Ambient Air


Ecologically Sensitive
Methods Of Measurement
Area (Notified By
Central Govt.)
20 g/m3
Improved West & Geake

Nitrogen Dioxide

24 hours

80 g/m 3

80 g/m 3

Annual
24 hours

40 g/m 3
80 g/m 3

30 g/m 3
80 g/m 3

Ultraviolet Fluorescence
Modified Jacob & Hochheiser (Na Arsenite)

(NOX)
Chemiluminescence

Particulate Matter (Size less than10 m) or PM10 g/m3

Particulate

Annual
24 hours

60 g/m 3
100 g/m 3

60 g/m 3
100 g/m 3

Annual

40 g/m 3

60 g/m 3

Gravimetric
TOEM
Beta attenuation
Gravimetric

Matter (size less than 2.5m) or PM2.5 g/m3

24 hours

60 g/m 3

60 g/m 3

Ozone (O3)

8 hours
1 hour

100 g/m3
180 g/m3

100 g/m3
180 g/m3

Annual

0.50 g/m3

0.50 g/m3

24 hours

1.0 g/m3

1.0 g/m3

8 hours

02 mg/m3

02 mg/m3

1 hour

04 mg/ m3

04 mg/ m3

Annual

100 g/m3

100 g/m3

24 hours

400 g/m3

400 g/m3

Chemiluminescence
Indophenol blue method

Benzene (C6H6)

Annual

05 g/m3

05 g/m3

GC
Adsorption & Desorption followed by
GC Analysis

Benzo(a)Pyrene
(BaP)-particulate
phase only

Annual

01 g/m3

01 g/m3

Solvent Extraction followed by


HPLC/GC analysis

Arsenic

Annual

06 g/m3

06 g/m3

AAS/ICP method after sampling on


EPM 2000 or equivalent filter paper

Lead (Pb)

Carbon Monoxide (CO)

Ammonia (NH3)

TOEM
Beta attenuation
UV photometric
Chemiluminescence Chemical Method
AAS/ICP method after sampling on
EPM 2000 or equivalent filter paper
EDXRF using Teflon filter

Non Dispersive Infra red (NDIR)


Spectroscopy

Nickel

Annual

20 g/m3

20 g/m3

AAS/ICP method after sampling on


EPM 2000 or equivalent filter paper

ANNUAL means Annual arithmetic mean of minimum 104 measurements in a year at a particulate site taken twice a week 24 hourly at uniform intervals.

24 Hours means 25 hourly or 08 hourly or 01 hourly monitored values, as applicable, shall be complied with 98% of the time in a year. 2% of the time, they may
exceed the limits but not on two consecutive days of monitoring.

Whenever & wherever monitoring results on two consecutive days of monitoring exceed the limit specified above for the respective category, it shall be considered adequate
reason to institute regular or continuous monitoring & further investigation.

Central Pollution Control Board has specified the air quality criteria, which is given in Table 2.
S. No.

Air Quality

Pollution Concentration

1.
2.
3.
4.

Low
Moderate
High
Critical

If less than half of the notified standards


If between half of the notified standards and the value of standards
If between the value of standards and 1.5 times the value of standards
If greater than the 1.5 times the value of the standards