207.5.

3 WIND LOAD DESIGN PROCEDURE


1. The basic wind speed V and wind directionality factor Kd
shall be determined in accordance with Section 207.5.4
and Table 207-2 repectively.
2. An importance factor Iw shall be determined
in accordance with Section 207.5.5.
3. An exposure category or exposure categories and velocity
pressure exposure coefficient Kz or Kh, as applicable,
shall be determined for each wind direction in accordance
with Section 207.5.6.
4. A topographic factor Kzt shall be determined in accordance
with Section 207.5.7.
5. A gust effect factor G or Gf, as applcable, shall be
determined in accordance with Section 207.5.8.
6. An enclosure classification shall be determined in accordance
with Section 207.5.9.
7. Internal pressure coefficient Gcpi shall be determined in
accordance with Section 207.5.11.1.
8. External pressure coefficient Cp or GCpf, or force
coefficients Cf, as applicable, shall be determined in
accordance with Section 207.5.11.2 or 207.5.11.3, respectively.
9. Velocity pressure qz or qh, as applcaible, shall be determined
in accordance with Section 207.5.10.
10. Design wind load p or F shall be determined in accordance with
Sections 207.5.12, 207.5.13, 207.5.14, and 207.5.15, as applicable.

Input Values on Blue Lanes


Input Values on Green Lanes in accordance with the tables in the next sheet.
Input Values on Yellow Lanes which came from linear interpolation from the tables.
Part 1.

Part 6.
1
2
3

Wind Speed V
Zone
2
V
200

kph
Part 7.

Directionality factor Kd
Kd
0.85
Part 2.
Importance Factor
Occupancy
Essential
I
1.15
Part 3.
V Exposure Coefficient Kz
z (height)
15
Exposure
C
Kz
0.85

Essential
Hazardous
Special
Standard
Miscellaneous
B1
B2
C
D

Part 8.

Part 4.
Topographic Factor Kzt
H
3
m
Lh
4
m
x
1
m
z
6
m
K1
0.5
K2
0.7
K3
0.5
Kzt
1.380625
Part 5.
Gust Effect Factor
G
0.85

Part 9.

Part 10.

Design Wind Loa

Enclosure
Enclosed

Windward
Leeward

Internal Pressure Coeff. Gcpi


+
GCpi
0.18
-

Sidewall
Roof

External Pressure Coeff Cp


Walls
L
30
m
B
10
m
L/B
3
Windward
0.8
Leeward
-0.3
Sidewall
-0.7
Roof
z
3
m
L
30
m
z/L
0.1

11.309932474
Cp
0.32

qz

Velocity Pressure qz
2.170364
kPa

Open
Enclosed

Partially Enclosed

Design Wind
1.0852
1.8665
-0.9441
-0.1628
-1.6820
-1.6820
0.1997
0.9810

Load
kPa
kPa
kPa
kPa
kPa
kPa
kPa
kPa

PRESSURE
SUCTION
PRESSURE
SUCTION
PRESSURE
SUCTION
PRESSURE
SUCTION

Zone

Table 1
Velocity

250 kph

200 kph

Province
Albay
Aurora
Batanes
Cagayan
Camarines Norte
Camarines sur
Catanduanes
Eastern samar
Isabela
Northern Samar
Quezon
Quirino
Samar
Sorsogon
Abra
Agusan Del Norte
Agusan Del Sur
Aklan
Antique
Apayao
Bataan
Batangas
Benguet
Biliran
Bohol
Bulacan
Camiguin
Capiz
Cavite
Cebu
Compostela Valley
Davao
Oriental
Guimaras
Ifugao
Ilocos Norte
Ilocos Sur
Iloilo
Kalinga
La Union
Laguna
Leyte

Table 2

Structural Type
Buildings
Main Wind Force Resisting System
Components and Cladding
Arched Roofs
Chimneys, Tanks, and Similar Structur
Square
Hexagonal
Round
Solid Sign
Open Signs and Latice Framework
Trussed Towers
Triangular, Square, Rectangular
All other cross sections
Table 3
Occupancy
Category
I
II
III
IV
V

Height
above
ground
level, z
0-4.5
6
7.5
9
12
15
18
21
24
27
30
36
42
48

Description
Essential
Hazardous
Special Occupancy
Standard Occupancy
Miscellaneous

Table 4
Exposure
B
Case 1
0.7
0.7
0.7
0.7
0.76
0.81
0.85
0.89
0.93
0.96
0.99
1.04
1.09
1.13

200 kph

150 kph

Marinduque
Masbate
Misamis Oriental
Mountain Province
NCR
Negros Occidental
Negros Oriental
Nueva Ecija
Nueva Vizcaya
Occidental Mindoro
Oriental Mindoro
Pampanga
Pangasinan
Rizal
Romblon
Siquijor
Southern Leyte
Surigao Del Norte
Surigao Del Sur
Tarlac
Zambales
Basilan
Bukidnon
Davao Del Norte
Davao Del Sur
Lanao Del Norte
Lanao Del Sur
Maguindanao
Misamis Occidental
North Cotabato
Palawan
Sarangani
South Cotabato
Sultan Kudarat
Sulu
Tawi-Tawi
Zambaonga Del Sur
Zamboanga Sibugay

54
60
75
90
105
120
135
150

Zg(m)

b
c
Do
(m)

Zmin(m)

1.17
1.2
1.28
1.35
1.41
1.47
1.52
1.56

Table 5
7
365
1/7
0.84
1/4
0.45
0.3
0.01
100
1/3
9

Table 2

ural Type
ldings
ing System
ing

Kd
H/Lh

0.85
0.85
0.85

0.2
0.25
0.3
0.35
0.4
0.45
0.5

and Similar Structures

d Sign
Latice Framework
d Towers
tangular

0.9
0.95
0.95
0.85
0.85

K1 Multiplier
2-D
2-D
Ridge
Escarp
0.29
0.36
0.43
0.51
0.58
0.65
0.72

0.17
0.21
0.26
0.3
0.34
0.38
0.43

0.85
0.95

Table 3
Description

Iw

Essential
Hazardous
Special Occupancy
tandard Occupancy
Miscellaneous

1.15
1.15
1.15
1
0.87

Table 4
Exposure (Note 1)
B
Case 2
0.57
0.62
0.66
0.7
0.76
0.81
0.85
0.89
0.93
0.96
0.99
1.04
1.09
1.13

Table 7
Enclosure Classification
Open Buildings
Partially Enclosed Buildings
Enclosed Buildings

C
Cases
1&2
0.85
0.9
0.94
0.98
1.04
1.09
1.13
1.17
1.21
1.24
1.26
1.31
2.36
1.39

D
Cases
1&2
1.03
1.08
1.12
1.16
1.22
1.27
1.31
1.34
1.38
1.4
1.43
1.48
1.52
1.55

Table 8
Wall Pressure Coefficient, Cp
Surface
L/B
Windward Wall
All Values
0-1
Leeward Wall
2
4
Side Wall
All Values

1.17
1.2
1.28
1.35
1.41
1.47
1.52
1.56

1.43
1.46
1.53
1.59
1.64
1.69
1.73
1.77

Table 5
9.5
275
2/19
1
2/13
0.65
0.2
0.005
150
1/5
4 1/2

11.5
215
2/23
1.07
1/9
0.8
0.15
0.003
200
1/8
2.1

1.58
1.61
1.68
1.73
1.78
1.82
1.86
1.89

1 Multiplier
3-D
Axisym.
Hill
0.21
0.26
0.32
0.37
0.42
0.47
0.53

Table 7
ssification
ldings

ed Buildings

uildings

x/Lh
0
0.5
1
1.5
2
2.5
3
3.5
4

Table 6
K2 Multiplier
2-D
All
Escarp
Other
Cases
1
1
0.88
0.67
0.75
0.33
0.63
0
0.5
0
0.38
0
0.25
0
0.13
0
0
0

GCpl
0
0.55
-0.55
0.18
-0.18

Table 8
Pressure Coefficient, Cp
L/B
Cp
All Values
0.8
0-1
-0.5
2
-0.3
4
-0.2
All Values
-0.7

Use with
qz
qh
qh

z/Lh
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.5
2

K3 Multiplier
2-D
2-D
3-D
Ridge
Escarp
Axisym.
Hill
1
1
1
0.74
0.78
0.67
0.55
0.61
0.45
0.41
1.47
0.3
0.3
0.37
0.2
0.22
0.29
0.14
0.17
0.22
0.09
0.12
0.17
0.06
0.09
0.14
0.04
0.07
0.11
0.03
0.05
0.08
0.02
0.01
0.02
0
0
0
0

Você também pode gostar