Escolar Documentos
Profissional Documentos
Cultura Documentos
ULDC
With DC motor
OLAER | ULDC
Olaer is a global player specializing in innovative, efficient system solutions for temperature optimization and energy storage.
All over the world, our products are working in the most diverse environments and applications.
Cooling capacity
the
right
cooler
requires
precise
Lifetime
skilled
engineers,
gives
you
the
temperature
temperature.
exceeds
the
ideal
working
www.olaerusa.com
OLAER | ULDC
Easy to maintain
DC motor
12V/24V
Quiet
fan and fan motor.
Smart DC Drive
The Smart DC Drive is for soft starting fan, as well as lower power consumption and sound level by means of temperaturecontrolled speed regulation. Smart DC Drive also eliminates voltage peaks, thus contributing towards a longer useful
life for the fan motor.
OLAER | ULDC
Installed
Horse Power
Flow?
Pressure?
Pump efficiency?
Measure in
your existing
unit
Contact
Olaer USA
representative.
Theoretical
Horse power
losses
www.olaerusa.com
OLAER | ULDC
Better energy consumption means not only less environmental impact, but also reduces operating costs, i.e. more cooling per $ invested.
continuously
friendly
hydraulic
seeking
to
capacity,
noise
OLAER | ULDC
The cooling capacity curves are based on the inlet oil temperature and the ambient air temperature.
An oil temperature of 140F and air temperature of 70 F produce a temperature difference of 70 F.
Multiply by Btu/hr/F for total cooling capacity.
1,600
Cooling performance
1,400
ULDC 033
1,200
ULDC 023
Btu/hr/F
1,000
ULDC 020
800
ULDC 016
600
ULDC 011
400
ULDC 007
ULDC 004
200
ULDC 003
0
10
20
40
30
50
60
70
90
80
45
Pressure Drop
40
Correction Factor*
35
30
25
033
1
0
50
003, 004
150
250
SSU
350
450
20
15
10
5
0
0
10
20
30
40
50
60
70
80
www.olaerusa.com
OLAER | ULDC
TYPE
Weight
lbs (Approx.)
Acoustic Pressure
LpA dB(A) 3ft*
Q
SAE O-ring Boss
11
13
20
26
33
40
55
66
68
68
68
68
68
68
68
68
1 (#16)
1 (#16)
1 (#16)
1 (#16)
1 (#16)
1 (#16)
1 (#16)
1 (#20)
ULDC 003
ULDC 004
ULDC 007
ULDC 011
ULDC 016
ULDC 020
ULDC 023
ULDC 033
* = Noise level tolerance 3 dB(A)
TYPE
ULDC 003
ULDC 004
ULDC 007
ULDC 011
ULDC 016
ULDC 020
ULDC 023
ULDC 033
8.9
10.0
13.3
15.6
18.3
20.1
25.0
26.7
2.5
3.5
3.7
3.4
3.4
3.0
5.4
3.4
3.5
3.5
6.3
9.0
11.7
13.8
14.9
19.1
3.2
3.2
3.2
2.8
3.2
3.2
5.2
6.0
8.0
8.0
8.0
8.0
14.0
14.0
0.9
0.9
0.9
0.9
0.9
0.9
1.0
7.8
9.0
11.7
14.3
17.0
18.7
20.2
24.5
5.3
5.3
8.0
14.2
16.4
18.5
-
9.6
10.5
13.0
15.7
18.3
20.1
24.2
25.0
5.8
4.6
5.9
5.8
5.2
6.0
10.5
6.8
6.8
4.0
7.9
8.5
4.0
9.3
8.3
4.0
10.1
8.3
11.4 7.9/18.0 8.6
11.4 7.9/18.0 10.1
N
dia./oblong
4.1
4.3
4.3
4.9
4.8
4.9
4.9
6.5
0.35 x 0.55
0.35 x 0.55
0.35
0.35 x 1.1
0.35 x 1.1
0.35 x 0.55
0.51
0.51
OLAER | ULDC
EXAMPLE:
ULDC - 007 - A - 000 - SA
Series
1
Model
2
Motor type
3
Thermoswitch
4
Core Bypass
5
Technical specification
Fluid combinations
2. COOLER SIZE/MODEL
003, 007, 011, 016, 020, 023, 033
3. Motor Voltage
12 V
24 V
Mineral oil
Oil/water emulsion
Water glycol
Phosphate ester
=A
=B
4. THERMOSwitch
No thermoswitch
100 F
120 F
140 F
160 F
175 F
195 F
Not listed, consult Olaer USA
5. COre bypass*
No Bypass
20 psi External Hose Bypass (standard option)
65 psi External Hose Bypass (standard option)
30 psi External Tube Bypass
75 psi External Tube Bypass
120 psi External Tube Bypass
120 F External Thermo-Bypass
140 F External Thermo-Bypass
160 F External Thermo-Bypass
195 F External Thermo-Bypass
Full Flow External Bypass
= 000
= 100
= 120
= 140
= 160
= 175
= 195
= ZZZ
Material
Cooler core
Fan blades/guard
Fan housing
Other parts
Surface treatment
Aluminum
Glass fiber reinforced polypropylene
Steel
Steel
Electrostatically powder-coated
cooler matrix
Maximum static working pressure
Dynamic working pressure
Heat transfer tolerance
Maximum oil inlet temperature
300 psi
200 psi*
6%
250 F
= SW
= SA
= SB
= SG
= SH
= SJ
= SM
= SN
= SP
= SQ
= SF
* The standard cores are single pass. Two pass cores and other options
available upon request, please consult Olaer USA.
www.olaerusa.com
OLAER | ULDC
Pressure-controlled
bypass valve Integrated
Allows the oil to bypass the cooler matrix if the
pressure drop is too high. Reduces the risk of
the cooler bursting, e.g. in connection with
cold starts and temporary peaks in pressure
cost-efficient
operation
and
better
matrix design.
Temperature-controlled
bypass valve Integrated
Same
function
as
the
pressure-controlled
tough conditions.
Thermo contact
Sensor with fixed set point for temperature warn-
Temperature-controlled
3-way valve External
OLAER | ULDC
Professional competence as well as advanced technology and extensive knowledge from the industry,
allow us to provide many cooler combinations, which meet your unique needs.
Combinations
providing optimal solutions
A
close
collaboration
between
our
application
Extensive choices
Long-term experience from the mobile field has
provided us with a unique ability to deliver the ideal
combination
cooler
solution.
Depending
on
the
10
www.olaerusa.com
OLAER | ULDC
11
Global perspective
in hand.
professional choice.
www.olaerusa.com